<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" dtd-version="3.0">
  <front>
    <journal-meta>
<journal-id journal-id-type="publisher">AMT</journal-id>
<journal-title-group>
<journal-title>Atmospheric Measurement Techniques</journal-title>
<abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">1867-8548</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>

    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-10-2253-2017</article-id><title-group><article-title>Use of a heated graphite scrubber as a means<?xmltex \hack{\break}?> of reducing interferences in
UV-absorbance<?xmltex \hack{\break}?> measurements of atmospheric ozone</article-title>
      </title-group><?xmltex \runningtitle{Graphite scrubber for reducing interferences in UV-absorbance O${}_{{3}}$ monitors}?><?xmltex \runningauthor{A. A. Turnipseed et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Turnipseed</surname><given-names>Andrew A.</given-names></name>
          <email>andrewt@twobtech.com</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Andersen</surname><given-names>Peter C.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Williford</surname><given-names>Craig J.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Ennis</surname><given-names>Christine A.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Birks</surname><given-names>John W.</given-names></name>
          
        </contrib>
        <aff id="aff1"><institution>2B Technologies, Inc., 2100 Central Ave., Boulder, CO 80301, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Andrew A. Turnipseed (andrewt@twobtech.com)</corresp></author-notes><pub-date><day>15</day><month>June</month><year>2017</year></pub-date>
      
      <volume>10</volume>
      <issue>6</issue>
      <fpage>2253</fpage><lpage>2269</lpage>
      <history>
        <date date-type="received"><day>4</day><month>January</month><year>2017</year></date>
           <date date-type="rev-request"><day>17</day><month>January</month><year>2017</year></date>
           <date date-type="rev-recd"><day>3</day><month>May</month><year>2017</year></date>
           <date date-type="accepted"><day>9</day><month>May</month><year>2017</year></date>
      </history>
      <permissions>
<license license-type="open-access">
<license-p>This work is licensed under the Creative Commons Attribution 3.0 Unported License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/3.0/">https://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions><self-uri xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017.html">This article is available from https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017.html</self-uri>
<self-uri xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017.pdf</self-uri>


      <abstract>
    <p>A new solid-phase scrubber for use in conventional ozone (O<inline-formula><mml:math id="M1" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
photometers was investigated as a means of reducing interferences from other
UV-absorbing species and water vapor. It was found that when heated to
100–130 <inline-formula><mml:math id="M2" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, a tubular graphite scrubber efficiently removed up to
500 ppb ozone and ozone monitors using the heated graphite scrubber were
found to be less susceptible to interferences from water vapor, mercury
vapor, and aromatic volatile organic compounds (VOCs) compared to
conventional metal oxide scrubbers. Ambient measurements from a graphite
scrubber-equipped photometer and a co-located Federal equivalent
method (FEM)
ozone analyzer showed excellent agreement over 38 days of measurements and
indicated no loss in the scrubber's ability to remove ozone when operated at
130 <inline-formula><mml:math id="M3" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. The use of a heated graphite scrubber was found to reduce
the interference from mercury vapor to <inline-formula><mml:math id="M4" display="inline"><mml:mo>≤</mml:mo></mml:math></inline-formula> 3 % of that obtained using
a packed-bed Hopcalite scrubber. For a series of substituted aromatic
compounds (ranging in volatility and absorption cross section at 253.7 nm),
the graphite scrubber was observed to consistently exhibit reduced levels of
interference, typically by factors of 2.5 to 20 less than with Hopcalite.
Conventional solid-phase scrubbers also exhibited complex VOC adsorption and
desorption characteristics that were dependent upon the relative humidity
(RH), volatility of the VOC, and the available surface area of the scrubber.
This complex behavior involving humidity is avoided by use of a heated
graphite scrubber. These results suggest that heated graphite scrubbers could
be substituted in most ozone photometers as a means of reducing interferences
from other UV-absorbing species found in the atmosphere. This could be
particularly important in ozone monitoring for compliance with the United
States (U.S.) Clean Air Act or for use in VOC-rich environments such as in
smog chambers and monitoring indoor air quality.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p>Ozone (O<inline-formula><mml:math id="M5" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> in the lower atmosphere is produced by a complex set of
photochemical reactions involving oxides of nitrogen and volatile organic
compounds (VOCs). It is well established that anthropogenic emissions of
these precursors lead to the production of elevated levels of ozone
(Haagen-Smit and Fox, 1954; Chameides and Walker, 1973). It also is
recognized that high levels of ozone are deleterious to human health (White
et al., 1994; Weisel et al., 1995; Burnett et al., 1997; U.S.-EPA, 2016) and
lead to plant and crop damage (Avnery et al., 2011; Emberson et al.,
2003, 2009). For these reasons, the Clean Air Act
in the United States (U.S.) and similar laws in other countries have set limits on ozone
concentrations in ambient air. Enforcement of compliance with the U.S.
National Ambient Air Quality Standards (NAAQS) requires monitoring of ozone
concentrations at hundreds of locations, especially during summer months when
photochemical ozone production is highest.</p>
      <p>Currently, compliance monitoring of ozone is done almost exclusively by the
method of UV absorbance at 253.7 nm due to the simplicity and reliability of
this technique. However, it has been shown that UV photometers suffer from
positive interferences from other trace gases that absorb at 253.7 nm such
as mercury (Hg) and VOCs (Huntzicker and Johnson, 1979; Grosjean and
Harrison, 1985; Kleindienst et al., 1993; Spicer et al., 2010). In addition,
water vapor, which does not absorb at 253.7 nm, is also a significant
interference in commercial ozone analyzers (Meyer et al., 1991; Kleindienst
et al., 1993) due to its ability to change the transmission of light through
the absorbance cell (Wilson and Birks, 2006). Field observations have noted
possible interferences in conventional UV-absorbance ozone monitors in very
highly polluted areas, such as Houston, TX (Olllison et al., 2013), and Mexico
City (Leston et al., 2005); however, other extensive studies have not shown
evidence of biases, even near urban areas (Ryerson et al.,
1998; Parrish and Fehsenfeld, 2000). Average
concentrations of interfering species found in outdoor air would normally be
expected to cause errors of only a few ppb at most, but this is well within
measurement limits of UV ozone photometers when averaged over the 1 h
time frame typical for compliance monitoring. Since high levels of
interferences often coincide with high levels of ambient outdoor ozone
(Leston et al., 2005; Ollison et al., 2013), a small, unpredictable bias
would be difficult to discern and could result in regions being in
noncompliance with the EPA ozone standard. The recent downward revision of
the standard from 75 to 70 ppb (8 h average) is expected to increase the
number of U.S. counties being out of compliance from 224 to 241 (McCarthy and
Lattanzio, 2016), making small ppb-level interferences a more critical issue.</p>
      <p>Other applications where interferences can play a significant role in
biasing UV-absorption O<inline-formula><mml:math id="M6" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> measurements include chamber-type experiments
and the monitoring of indoor ozone. In the former, high VOC concentrations
are typically used to enhance photochemistry (e.g., Leston et al., 2005;
Griffin et al., 1999) or to generate aerosols (e.g., Lee et al., 2006), thus
requiring accurate O<inline-formula><mml:math id="M7" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> concentrations to be made in VOC-rich
atmospheres. Indoor ozone concentrations are typically 20–80 % of that
measured outdoors (U.S.-EPA, 2016); however, interfering species such as
VOCs and mercury can be at much higher concentrations indoors from attached
garages, cooking emissions, unvented heaters, the use of paints, cleaners,
and outgassing from building components. This places even more stringent
constraints on ozone monitors to reduce biases in these indoor environments.</p>
      <p>Ambient ozone UV-absorbance measurements are conducted by observing the
attenuation of transmission of the mercury emission line at 253.7 nm (near
the maximum in the ozone absorption spectrum) through an absorbance cell.
Relative light intensities are measured for a direct air sample (<inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:mi>I</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and an
air sample where the ozone is removed by some type of ozone scrubber
(<inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and the ozone concentration is computed using the Beer–Lambert law.
Ozone scrubbers are typically composed of manganese dioxide, charcoal,
Hopcalite, metal-oxide-coated screens, or heated silver wool and play a key
role in the degree to which interferences compromise the ozone readings in
UV-absorption photometers. For chemical species that absorb 253.7 nm light,
the degree of interference depends on the compound's absorption cross
section, its ambient concentration, and the degree to which the compound is
removed by the scrubber. If not removed by the scrubber, its concentration
remains constant between <inline-formula><mml:math id="M10" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurements and cancels out in the
Beer–Lambert law. Thus the ideal scrubber would have two characteristics:
(1) it would quantitatively remove ozone and (2) it would not remove other
species that absorb at 253.7 nm or that otherwise modify light transmission
to the detector such as water vapor. The metal oxide scrubbers used in
conventional commercially available ozone photometers do not fully meet the
second criterion, leading to errors in the Beer–Lambert law calculation of
ozone.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><caption><p>Properties of VOCs and other atmospheric species that are potential
interferents in UV-absorption-based ozone
measurements.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Interferent</oasis:entry>  
         <oasis:entry colname="col2">Ambient mixing</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mn mathvariant="normal">254</mml:mn><mml:mi mathvariant="normal">b</mml:mi></mml:msubsup></mml:mrow></mml:math></inline-formula>, 10<inline-formula><mml:math id="M20" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M21" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:msubsup><mml:mi>e</mml:mi><mml:mi mathvariant="normal">v</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msubsup></mml:mrow></mml:math></inline-formula>, (25 <inline-formula><mml:math id="M23" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:msup><mml:mi>S</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula>,</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">(INT)</oasis:entry>  
         <oasis:entry colname="col2">ratio<inline-formula><mml:math id="M25" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula>, ppb</oasis:entry>  
         <oasis:entry colname="col3">molecule<inline-formula><mml:math id="M26" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">mm Hg</oasis:entry>  
         <oasis:entry colname="col5">ppb INT/ppb O<inline-formula><mml:math id="M27" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">  
         <oasis:entry namest="col1" nameend="col5">Used in this study </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M28" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-Xylene</oasis:entry>  
         <oasis:entry colname="col2">0.3–30</oasis:entry>  
         <oasis:entry colname="col3">0.057</oasis:entry>  
         <oasis:entry colname="col4">8.84</oasis:entry>  
         <oasis:entry colname="col5">20.2</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Phenol</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.16</oasis:entry>  
         <oasis:entry colname="col4">0.350</oasis:entry>  
         <oasis:entry colname="col5">7.1</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M30" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-Tolualdehyde</oasis:entry>  
         <oasis:entry colname="col2">&lt; 1</oasis:entry>  
         <oasis:entry colname="col3">0.55</oasis:entry>  
         <oasis:entry colname="col4">0.250</oasis:entry>  
         <oasis:entry colname="col5">2.09</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M31" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-Nitrophenol</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0.001</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">2.15</oasis:entry>  
         <oasis:entry colname="col4">0.113</oasis:entry>  
         <oasis:entry colname="col5">0.53</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">Mercury</oasis:entry>  
         <oasis:entry colname="col2">0.0002–0.003</oasis:entry>  
         <oasis:entry colname="col3">1860<inline-formula><mml:math id="M33" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">e</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">0.002</oasis:entry>  
         <oasis:entry colname="col5">0.0005</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry namest="col1" nameend="col5">Typical atmospheric constituents </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">NO<inline-formula><mml:math id="M34" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.001</oasis:entry>  
         <oasis:entry colname="col4">741</oasis:entry>  
         <oasis:entry colname="col5">1000</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">SO<inline-formula><mml:math id="M36" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">1–25</oasis:entry>  
         <oasis:entry colname="col3">0.014</oasis:entry>  
         <oasis:entry colname="col4">3000</oasis:entry>  
         <oasis:entry colname="col5">77</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Methanol</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">40</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">&lt; 0.00001</oasis:entry>  
         <oasis:entry colname="col4">127</oasis:entry>  
         <oasis:entry colname="col5">&gt; 10 000</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Acetone</oasis:entry>  
         <oasis:entry colname="col2">0.2–9</oasis:entry>  
         <oasis:entry colname="col3">0.0030</oasis:entry>  
         <oasis:entry colname="col4">231</oasis:entry>  
         <oasis:entry colname="col5">290</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Formaldehyde</oasis:entry>  
         <oasis:entry colname="col2">0.5–75</oasis:entry>  
         <oasis:entry colname="col3">0.00029</oasis:entry>  
         <oasis:entry colname="col4">3890</oasis:entry>  
         <oasis:entry colname="col5">3960</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Acetaldehyde</oasis:entry>  
         <oasis:entry colname="col2">0.1–18</oasis:entry>  
         <oasis:entry colname="col3">0.0015</oasis:entry>  
         <oasis:entry colname="col4">902</oasis:entry>  
         <oasis:entry colname="col5">590</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">1,3-Butadiene</oasis:entry>  
         <oasis:entry colname="col2">0.1–6</oasis:entry>  
         <oasis:entry colname="col3">&lt; 0.02</oasis:entry>  
         <oasis:entry colname="col4">1840</oasis:entry>  
         <oasis:entry colname="col5">&gt; 58</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Trichloroethene</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0.2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.0041</oasis:entry>  
         <oasis:entry colname="col4">69</oasis:entry>  
         <oasis:entry colname="col5">265</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">2-Butanone</oasis:entry>  
         <oasis:entry colname="col2">0.1–8</oasis:entry>  
         <oasis:entry colname="col3">0.0031</oasis:entry>  
         <oasis:entry colname="col4">90.6</oasis:entry>  
         <oasis:entry colname="col5">370</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Isoprene</oasis:entry>  
         <oasis:entry colname="col2">0.1–5.5</oasis:entry>  
         <oasis:entry colname="col3">0.0052</oasis:entry>  
         <oasis:entry colname="col4">550</oasis:entry>  
         <oasis:entry colname="col5">220</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Octane</oasis:entry>  
         <oasis:entry colname="col2">0.02–13</oasis:entry>  
         <oasis:entry colname="col3">&lt; 0.0002</oasis:entry>  
         <oasis:entry colname="col4">14.1</oasis:entry>  
         <oasis:entry colname="col5">&gt; 5700</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Methacrolein</oasis:entry>  
         <oasis:entry colname="col2">0.02–1.7</oasis:entry>  
         <oasis:entry colname="col3">0.00018</oasis:entry>  
         <oasis:entry colname="col4">155</oasis:entry>  
         <oasis:entry colname="col5">6400</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Methyl vinyl ketone</oasis:entry>  
         <oasis:entry colname="col2">0.2–1.5</oasis:entry>  
         <oasis:entry colname="col3">0.00024</oasis:entry>  
         <oasis:entry colname="col4">152</oasis:entry>  
         <oasis:entry colname="col5">4790</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Acetic acid</oasis:entry>  
         <oasis:entry colname="col2">0.5–10</oasis:entry>  
         <oasis:entry colname="col3">&lt; 0.0006</oasis:entry>  
         <oasis:entry colname="col4">15.7</oasis:entry>  
         <oasis:entry colname="col5">&gt; 1900</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M39" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-Pinene</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0.4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.00054</oasis:entry>  
         <oasis:entry colname="col4">4.75</oasis:entry>  
         <oasis:entry colname="col5">2120</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">d-Limonene</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.015</oasis:entry>  
         <oasis:entry colname="col4">1.55</oasis:entry>  
         <oasis:entry colname="col5">77</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry namest="col1" nameend="col5">Aromatics </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Benzene</oasis:entry>  
         <oasis:entry colname="col2">0.9–26</oasis:entry>  
         <oasis:entry colname="col3">0.03</oasis:entry>  
         <oasis:entry colname="col4">94.8</oasis:entry>  
         <oasis:entry colname="col5">38</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Toluene</oasis:entry>  
         <oasis:entry colname="col2">0.05–39</oasis:entry>  
         <oasis:entry colname="col3">0.039</oasis:entry>  
         <oasis:entry colname="col4">28.4</oasis:entry>  
         <oasis:entry colname="col5">29</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M42" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-Xylene</oasis:entry>  
         <oasis:entry colname="col2">0.4–1</oasis:entry>  
         <oasis:entry colname="col3">0.048</oasis:entry>  
         <oasis:entry colname="col4">6.5</oasis:entry>  
         <oasis:entry colname="col5">24</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Ethylbenzene</oasis:entry>  
         <oasis:entry colname="col2">0.08–16.5</oasis:entry>  
         <oasis:entry colname="col3">0.052</oasis:entry>  
         <oasis:entry colname="col4">9.6</oasis:entry>  
         <oasis:entry colname="col5">22</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Styrene (vinyl benzene)</oasis:entry>  
         <oasis:entry colname="col2">0.06–3.1</oasis:entry>  
         <oasis:entry colname="col3">1.3</oasis:entry>  
         <oasis:entry colname="col4">6.4</oasis:entry>  
         <oasis:entry colname="col5">0.88</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">1,3,5-Trimethylbenzene</oasis:entry>  
         <oasis:entry colname="col2">0.03–4.2</oasis:entry>  
         <oasis:entry colname="col3">0.037</oasis:entry>  
         <oasis:entry colname="col4">2.48</oasis:entry>  
         <oasis:entry colname="col5">31</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M43" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-Cresol</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">0.004</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.108</oasis:entry>  
         <oasis:entry colname="col4">0.11</oasis:entry>  
         <oasis:entry colname="col5">10.6</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Benzaldehyde</oasis:entry>  
         <oasis:entry colname="col2">0.1–1</oasis:entry>  
         <oasis:entry colname="col3">0.09</oasis:entry>  
         <oasis:entry colname="col4">0.127</oasis:entry>  
         <oasis:entry colname="col5">12.8</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Naphthalene</oasis:entry>  
         <oasis:entry colname="col2">0.01–0.1</oasis:entry>  
         <oasis:entry colname="col3">1.07</oasis:entry>  
         <oasis:entry colname="col4">0.08</oasis:entry>  
         <oasis:entry colname="col5">1.07</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Nitrobenzene</oasis:entry>  
         <oasis:entry colname="col2">0.02–0.40</oasis:entry>  
         <oasis:entry colname="col3">1.3</oasis:entry>  
         <oasis:entry colname="col4">0.245</oasis:entry>  
         <oasis:entry colname="col5">0.88</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p><inline-formula><mml:math id="M12" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula> Typical concentration ranges reported in
Finlayson-Pitts and Pitts (2000), Seila et al. (1989), Mahmoud et al. (2002),
Bernardo-Bricker et al. (1995), Delhomme et al. (2010), Davies (2003),
Eiguren-Fernandez et al. (2004), Liu et al. (2002), Denis et al. (2006).
<inline-formula><mml:math id="M13" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula> Absorbance cross sections at 253.7 nm taken from
Keller-Rudek et al. (2013) and the related web database
(<uri>http://www.uv-vis-spectral-atlas-mainz.org/</uri>). <inline-formula><mml:math id="M14" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula> Vapor
pressures taken from <uri>http://pubchem.ncbi.nlm.nih.gov/</uri>.
<inline-formula><mml:math id="M15" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">d</mml:mi></mml:msup></mml:math></inline-formula> Selectivity ratio, <inline-formula><mml:math id="M16" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow class="chem"><mml:mi mathvariant="normal">int</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, at 253.7 nm. To estimate the maximum response that a
particular interferent could give in an ozone monitor, divide the ambient
mixing ratio by the selectivity ratio, <inline-formula><mml:math id="M17" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>. <inline-formula><mml:math id="M18" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">e</mml:mi></mml:msup></mml:math></inline-formula> From Birks et
al. (2009).</p></table-wrap-foot></table-wrap>

      <p>A further, less obvious problem with UV-absorbing species is that they can
desorb from the solid-phase scrubber at later times, causing a negative
absorbance (value of <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is less than <inline-formula><mml:math id="M46" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> in ozone-free air), thus imparting
a negative bias to the overall measurement. This desorption can be caused by
temperature or relative humidity (RH) changes within the scrubber that alter the
adsorption characteristics of a species and allows it to be released back
into the gas phase. Because UV-absorbing compounds and mercury are commonly
present to some degree in both indoor and outdoor air, these interferences
may be responsible in part for the baseline drift that occurs in photometric
ozone monitors (Birks et al., 2013; Ollison et al., 2013). Therefore,
development of a solid-phase scrubber that effectively destroys ozone (<inline-formula><mml:math id="M47" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 99 % destruction) but efficiently passes interfering species is
desirable.</p>
      <p>Table 1 provides a list of several atmospheric constituents with known
253.7 nm absorption cross sections along with a selectivity ratio (<inline-formula><mml:math id="M48" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>),
defined as the ratio of the ozone cross section to that of the interfering
compound at 253.7 nm. Notable among these are VOCs that contain an aromatic
group. The absorption cross sections of these compounds vary widely, but can
be similar to that of ozone, depending on the types of functional groups
attached. Gaseous mercury is a particularly strong interference because the
electronic energy levels of Hg atoms are resonant with the Hg emission line
used in most ozone monitors. The relative response of mercury has been
estimated at <inline-formula><mml:math id="M49" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1 ppb O<inline-formula><mml:math id="M50" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg (Spicer et al., 2010; Li
et al., 2006). So even a few ppt of mercury vapor can potentially cause
substantial biases in ozone measurements.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><caption><p><bold>(a)</bold> Schematic diagram of a typical single-beam
UV-absorbance monitor for ozone. <bold>(b)</bold> Schematic of the heated
graphite scrubber consisting of four graphite tubes contained within a
temperature-controlled aluminum block.</p></caption>
        <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f01.png"/>

      </fig>

      <p>In this study we present a means of greatly reducing the interferences of
mercury, UV-absorbing VOCs, and water vapor in ozone measurements by
replacing conventional metal oxide internal ozone scrubbers with a heated
graphite scrubber (Birks et al., 2016). Carbon-based scrubbers have often
been used for removing ozone from air (Shields et al., 1999; Lee and
Davidson, 1999). However, these scrubbers also effectively remove many other
compounds (such as VOCs and water) by adsorption due to their large surface
area (typically 500–3000 m<inline-formula><mml:math id="M51" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> g<inline-formula><mml:math id="M52" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) and thus provide no significant
advantage over existing ozone scrubbers. On the other hand, carbon in the
form of graphite has a more ordered planar structure with less surface area
(often &lt; 20 m<inline-formula><mml:math id="M53" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> g<inline-formula><mml:math id="M54" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) and fewer sites available for adsorption of
possible interfering compounds. We show that a heated graphite scrubber
composed of one or more graphite tubes effectively destroys ozone while
efficiently passing most UV-absorbing species and is relatively insensitive
to humidity changes. Our results suggest that replacement of conventional
scrubbers in commercially available ozone photometers with heated graphite
scrubbers could increase their accuracy by reducing potential interferences.</p>
</sec>
<sec id="Ch1.S2">
  <title>Experimental</title>
      <p>Most experiments were carried out with modified FEM 2B Technologies single-beam Model 202 and
dual-beam Model 205 or Model 211 ozone monitors. Figure 1a shows a diagram of a typical single-beam UV ozone photometer such as the
Model 202. Ambient air samples are drawn into the instrument through an
inlet via an air pump. A solenoid valve alternately switches the gas sample
directly into the optical detection cell or through an ozone scrubber and
then into the detection cell. UV light from a low-pressure mercury lamp passes through the detection cell and is detected by a photodiode
containing a built-in interference filter centered at 254 nm. The ozone
concentration is calculated using the Beer–Lambert law,
          <disp-formula id="Ch1.E1" content-type="numbered"><mml:math id="M55" display="block"><mml:mrow><mml:mfenced close="]" open="["><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:mfenced><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>L</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mi>ln⁡</mml:mi><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow><mml:mi>I</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
        where <inline-formula><mml:math id="M56" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> is the absorption cross section for ozone (<inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.15</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math id="M58" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molecule<inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M60" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> is the
path of the detection cell, <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the lamp intensity at the
detector in the absence of ozone, and <inline-formula><mml:math id="M62" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> is the lamp intensity with ozone
present. The path length (<inline-formula><mml:math id="M63" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>) is 15 cm for the 2B Technologies Model 202
and Model 205 ozone monitors. The Model 205 (and Model 211) analyzer differs
in that it is a typical dual-beam instrument containing two optical cells
irradiated by the same lamp, but with each cell equipped with its own
photodiode. Two three-way solenoid valves are switched to alternate passage
of ozone-scrubbed and un-scrubbed air through the two cells, providing a
simultaneous measurement of <inline-formula><mml:math id="M64" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. These analyzers were
modified to locate the ozone scrubber outside of the instrument, allowing for
easy exchange between the different scrubbers tested. Mixtures of interfering
compounds in air were sampled into the ozone analyzers via an overflow tee
where excess air was vented through a second scrubber to the atmosphere. All
analyzers used were operating at manufacturer specifications.</p>
      <p>Graphite scrubbers consisted of different combinations of graphite tubes
(<inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> in o.d. and <inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula> in i.d., Ohio Carbon Blank, EDM-AF5 graphite)
housed in a temperature-controlled aluminum block. Tube lengths were either
7.6 cm (3 in) or 15.2 cm (6 in). Most results were obtained using four
7.6 cm tubes plumbed in parallel as shown in Fig. 1b. Using multiple tubes
increased both surface area and residence time while still maintaining high
flow conductance. This configuration was chosen because it quantitatively
destroyed (&gt; 99 %) ozone in the single-beam Model 202 Ozone
Monitor and fit within both Model 202 and 205 instruments. The aluminum block
was heated with a cartridge heater (Thermal Corp., no. CPN20528), whose
temperature could be varied up to 160 <inline-formula><mml:math id="M68" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and controlled to within
<inline-formula><mml:math id="M69" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2 <inline-formula><mml:math id="M70" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. The graphite tubes were cleaned before use by heating at
300 <inline-formula><mml:math id="M71" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for 12 h while purging with ultra-high purity (UHP) nitrogen and sonication for
20 min in dilute Micro-90 glass cleaner followed by rinsing with distilled
water and drying. Scrubbers consisting of coarsely ground EDM-AF5 graphite
(<inline-formula><mml:math id="M72" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1–3 mm diameter particles) were also tested and exhibited similar
properties for both ozone destruction and the reduction of interferences.
However, we present results from the tube scrubbers because their geometric
surface area and residence times were more easily characterized.</p>
      <p>Other commercially available scrubbers were included in this study for
comparison. These include the conventional packed-bed Hopcalite scrubber
used in 2B Technologies analyzers as well as manganese-oxide-coated screens from a
Thermo Electron Model 49C and a Teledyne Advanced Pollution Instrumentation
(API)
Model 400E. We also tested heated silver wool scrubbers similar to scrubbers
used by Horiba. It should be noted that although these various scrubbers
were used within 2B Technologies analyzers, pressure and flow conditions
were similar to those in the respective commercial analyzers. However, small
differences in operating conditions of the various commercial analyzers may
alter results in those instruments compared to those presented here.</p>
      <p>Dry air (&lt; 2 % relative humidity) was produced using a zero
air generator (Aadco, Model 737) or from cylinders of zero grade air.
Ozone–air mixtures and ozone-free air were produced via an ozone calibrator
– a Model 306 Ozone Calibration Source<sup>™</sup>
(2B Technologies). The Model 306 instrument qualifies as an EPA transfer
standard for ozone and can produce known mixing ratios of ozone via UV
photolysis of air in the range between 0 and 1 ppm. Humidity was varied by
humidifying the source air for the Model 306. A mixing tee was placed on the
source line of the Model 306 with one end pulling through a water bubbler and
the other through a drying tube (Drierite). Needle valves on each line
allowed for independent control over the source line between the dry and
humid air. Humidity was measured in the overflow just downstream of the ozone
monitor via a temperature–humidity sensor (Omega, model HH311).</p>
      <p>Mercury vapor was introduced to the ozone analyzer by using a glass
diffusion tube. A small amount of liquid mercury was placed in a glass bulb,
and vapor was allowed to diffuse through a 20 cm long capillary tube (i.d. <inline-formula><mml:math id="M73" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.5 mm). At the exit of the capillary tube, a small sweep flow of air
(<inline-formula><mml:math id="M74" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5–15 cc min<inline-formula><mml:math id="M75" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) purged the mercury vapor into the main airflow
(<inline-formula><mml:math id="M76" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 3 L min<inline-formula><mml:math id="M77" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). Mercury concentrations were varied by immersing the
reservoir and capillary tube in an insulated water bath and varying the
temperature of the bath (0 to 60 <inline-formula><mml:math id="M78" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C). From bath temperature, flow
rates, and the mercury vapor pressure, estimated mercury vapor concentrations
of 0.3 to 30 ppb were produced. Mercury interference measurements were made
relative to the 2B packed-bed Hopcalite scrubber.</p>
      <p>Table 1 summarizes the absorption cross sections at 253.7 nm for a variety
of atmospheric species including compounds tested in this study. Test
compounds were chosen because they are either common outdoor (<inline-formula><mml:math id="M79" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene) or
indoor (phenol) pollutants or for comparison with previous studies (Spicer
et al., 2010). Typically, gas mixtures between 5 and 25 ppm were made in
preconditioned gas cylinders by dilution of the pure compound in UHP
nitrogen. These were further diluted with zero grade air via mass flow
controllers to produce mixing ratios in the range of 0.01–1.4 ppm.
Low-volatility (<inline-formula><mml:math id="M80" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol) VOCs were added using diffusion tubes in a similar way to
that described for mercury above. Sample purity was assessed using a gas
chromatograph with flame ionization and mass spectrometric detection
(GC-FID-MS). The VOC–air mixtures were sampled into ozone analyzers
equipped with different scrubbers from an overflow tee. In some experiments,
the VOC–air flow was simultaneously sampled into the inlet system of a gas
chromatograph equipped with a flame ionization detector (GC-FID). VOC
samples were pre-concentrated via a cooled (<inline-formula><mml:math id="M81" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>5 <inline-formula><mml:math id="M82" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) focusing trap
containing Tenax TA (typically 100–500 cm<inline-formula><mml:math id="M83" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> of the VOC–air mixture) and
then rapidly heated to inject as described in Greenberg et al. (1994). Both
GC systems were calibrated with a National Institute of Science and Technology
certified primary standard of
neohexane in nitrogen or a secondary VOC standard containing isoprene and
camphene.</p>
</sec>
<sec id="Ch1.S3">
  <title>Results and discussions</title>
      <p>As mentioned previously, any species absorbing light at 253.7 nm will be
detected if its concentration is changed by the ozone scrubber, and thus an
ideal ozone scrubber would remove all ozone but quantitatively pass
interferents such as water vapor and UV-absorbing species. The following
sections test the graphite scrubber against this ideal, followed by
comparative tests with existing conventional scrubbers for known
interferences.</p>
<sec id="Ch1.S3.SS1">
  <title>Ozone removal efficiency</title>
      <p>It has long been known that ozone reacts with graphite (Hennig, 1965; Tracz
et al., 2003), causing loss of the carbon surface (Razumovskii et al., 2007)
with the assumed production of CO and CO<inline-formula><mml:math id="M84" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>. CO and CO<inline-formula><mml:math id="M85" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> have been
identified as the primary products from reactions of ozone with carbon black
aerosols which are thought to be similar to graphitic carbon (Stephens et
al., 1989; Smith and Chughtai, 1996; Saathoff et al., 1998). CO, CO<inline-formula><mml:math id="M86" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>,
and other possible low-volatility hydrocarbons which could be lost to the
gas phase tend to show negligible absorption at 253.7 nm (Table 1) compared
to ozone. A graphite scrubber is not catalytic (i.e., there is actual loss
of the scrubber carbon), but it can be estimated that a typical 7.6 cm long
graphite tube would require a continuous 200 ppb ozone exposure at a flow
rate of 1 L min<inline-formula><mml:math id="M87" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for 213 days to lose 1 % of its carbon; at 100 <inline-formula><mml:math id="M88" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C
oxidation by ambient O<inline-formula><mml:math id="M89" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> is also negligible (Entegris, 2015).</p>
      <p>Initial tests of the graphite scrubber using four parallel 15.2 cm graphite
tubes at room temperature showed nearly complete removal of ozone up to 250 ppb in the Model 202; however, the ozone removal efficiency degraded over
several hours as the graphite surface became oxidized. Heating the graphite
tubes to 100–130 <inline-formula><mml:math id="M90" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C resulted in complete recovery of the
graphite's reactivity toward ozone, but large negative absorbances were
observed in the ozone analyzers as the temperature of the graphite scrubber
exceeded 145 <inline-formula><mml:math id="M91" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. This was due to the emission of various volatile
organic hydrocarbons from the graphite tubes as verified by GC-MS. We
attribute this to either the thermal breakdown of the organic binder
contained in graphite that is added during manufacturing or to initiation
of O<inline-formula><mml:math id="M92" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> oxidation, although the latter is not expected to be significant
below about 350 <inline-formula><mml:math id="M93" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (Entegris, 2015). Below 135 <inline-formula><mml:math id="M94" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C,
emissions were greatly reduced and, after completing the cleaning process
described above, typically resulted in a small negative offset
(<inline-formula><mml:math id="M95" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M96" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>2 to <inline-formula><mml:math id="M97" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>5 ppb) that remained constant over time. The exact
cause of this small residual negative offset is unclear, although it is
likely due to residual organics that are slowly released from the hot
graphite. As in the case of conventional ozone scrubbers, this small offset
can be incorporated into the calibration parameters of the ozone analyzer.</p>
      <p>We conclude that a tube configuration consisting of four 3.175 mm
(<inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula> in) i.d., 7.62 cm (3 in) long parallel graphite tubes (Fig. 1b),
which easily fit within the existing Model 202 Ozone Monitor enclosure,
provides adequate (&gt; 98 %) ozone destruction efficiency
comparable with conventional scrubbers. This scrubber has an internal volume
of 2.4 cm<inline-formula><mml:math id="M99" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> and a geometric surface area of 30.4 cm<inline-formula><mml:math id="M100" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula>, resulting in a
residence time of 0.145 s for a typical flow rate of 1 L min<inline-formula><mml:math id="M101" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. At a
temperature of 100 <inline-formula><mml:math id="M102" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and pressure of 1 atm, on average each ozone
molecule collides with the surface <inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.85</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> times while passing
through the scrubber. Thus, assuming rapid diffusion to the walls, a
collisional reaction probability <inline-formula><mml:math id="M104" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula> of <inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1.7</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> is
required to assure &gt; 99 % ozone destruction. This is similar
in magnitude to previously determined probabilities of ozone uptake on fresh
carbon soot surfaces (Burkholder et al., 2015). The results discussed in the
remainder of this paper were observed with this scrubber design, although the
graphite surface area could be increased if necessary. Figure 2 shows
examples of calibration plots where the ozone was varied and the graphite
scrubber was alternately replaced with a conventional packed-bed Hopcalite
scrubber. To test for reproducibility, four different sets of graphite tubes
were used within the heater. Slopes of heated graphite vs. Hopcalite ozone
measurements ranged from 0.96 to 1.01 among the different sets for
concentrations up to 500 ppb of ozone. The overall average slope was 0.98.
All calibration plots were highly linear with <inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> &gt; 0.99, and
their slopes were invariant over the graphite scrubber temperature range of
100–130 <inline-formula><mml:math id="M107" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <title>Long-term reliability of the graphite scrubber</title>
      <p>A primary concern with carbon-based scrubbers is that as the surface of the
solid-phase carbon oxidizes, it becomes less reactive toward ozone. In
principle, the carbon is oxidized to CO and CO<inline-formula><mml:math id="M108" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, which desorb to the
gas phase and are swept away in the case of a flowing analyzer. However, the
oxidation to CO and CO<inline-formula><mml:math id="M109" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> in the presence of water vapor typically occurs
in several steps through various oxygenated intermediates (i.e., epoxides,
alcohols, aldehydes, and ketones), and it is likely that at least some of
the carbon lost is in the form of small oxygenated organics such as
formaldehyde, acetone, and acetaldehyde. These do not present a problem as
long as they do not absorb appreciably at 253.7 nm. Ellis and Tometz (1972)
were among the first to note that upon exposure to high ozone
concentrations, coconut charcoal becomes less efficient at removing ozone
as it oxidizes. This suggests that oxygenated hydrocarbons on the graphite
surface or oxygen functionalities incorporated within the graphite structure
have slower ozone reaction rates. A loss in reactivity toward ozone has also
been observed for graphite at high (<inline-formula><mml:math id="M110" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 0.5 %) levels of ozone
(Razumovskii et al., 2007). We also observed this loss in ozone removal
efficiency at room temperature and found that heating the graphite scrubber
remedies this problem. At elevated temperatures (100 <inline-formula><mml:math id="M111" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C),
continuous exposure of 150 ppb of ozone for 22 h in the single-beam
Model 202 showed no loss of the graphite's ability to destroy ozone.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p>Plot of ozone measured with the graphite scrubber (at
100 <inline-formula><mml:math id="M112" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) vs. that measured with the conventional Hopcalite scrubber.
The different symbols/colors represent different sets of graphite tubes used
within the heater during our reproducibility testing. Results were obtained
using a 2B Technologies Model 202 single-beam ozone analyzer. The dashed line
drawn is the 1 : 1 line.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f02.pdf"/>

        </fig>

      <p>However, incorporation of the graphite scrubber into a dual-beam Model 205
led to unexpected complications. We found that even at 100 <inline-formula><mml:math id="M113" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, it
was necessary to reduce the flow rate to the minimum required to flush the
absorbance cells in order to observe 100 % ozone removal. Furthermore,
overnight exposure (18 h) of the graphite tubes to 150 ppb of O<inline-formula><mml:math id="M114" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> in
the dual-beam Model 205 resulted in a 10 % loss of the ozone removal
efficiency. Exposure to higher ozone concentrations (300–700 ppb) in the
dual-beam Model 205 resulted in faster temporal decays which leveled off at
<inline-formula><mml:math id="M115" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 % ozone removal efficiency after 2 to 8 h. The
graphite's capacity to destroy ozone could be restored by periodically
heating the graphite to 150 <inline-formula><mml:math id="M116" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for 20–30 min or by removal of
the ozone exposure while continuing with normal analyzer operation for 3–6 h. Ellis and Tometz (1972) also had noted that removal of charcoal from
ozone exposure for several hours resulted in a regeneration of the surface
reactivity toward ozone.</p>
      <p>These observations suggest a competition between ozone oxidizing the
graphite surface (making less reactive species at the surface) and loss of
these oxidized carbon-containing compounds to the gas phase (which
presumably exposes new, less oxidized surface area). This competition helps
explain why the single-beam Model 202 is less susceptible to losing
reactivity toward ozone since the scrubber is only exposed to ozone flow
half of the time (during the <inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurement). During the
<inline-formula><mml:math id="M118" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> measurement, there is no flow through the scrubber, but oxidized compounds
can still desorb and regenerate the surface. In the dual-beam monitor, the
graphite is continuously exposed to a flow of ozone as it is always directed
to one of the two cells for an <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurement. As a result, the surface
is being oxidized faster than the graphite can regenerate. One also expects
this competition to be dependent upon the temperature of the scrubber and
the flow rate through it as well as the ozone concentration.</p>
      <p>Therefore, before the graphite scrubber can be used in long-term continuous
monitoring, it is necessary to fully understand its limitations in terms of
its loss of ozone removal efficiency. To further characterize the graphite
scrubber, we undertook extended ambient ozone measurements on the 2B
Technologies roof in Boulder, CO, during August and September of 2015. A
single-beam Model 202 was equipped with our heated graphite scrubber
(denoted as 202-G) and sampled from the same Teflon inlet line as an FEM
(Federal equivalent method) Model 205 dual-beam analyzer with a conventional
packed-bed Hopcalite scrubber (205-H). The Model 205 was equipped with
Nafion for humidity equilibration; however, Nafion was removed from the
Model 202 graphite scrubber analyzer (humidity interference is discussed in
Sect. 3.3). Calibrations were performed on both instruments prior to and
periodically throughout the comparison with a Model 306 ozone calibrator.
Although the 205-H may be more susceptible to interfering compounds
(described in following section), the anticipated bias is &lt; 3 ppb.</p>
      <p>We initially evaluated the graphite scrubber temperature at 100 <inline-formula><mml:math id="M120" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C
since we had observed no loss of ozone removal efficiency during lab ozone
exposure experiments with our single-beam ozone instrument. Ambient
measurements were made from 8–24 August 2015. Ozone data was averaged to
5 min from both instruments (205-H and 202-G) and compared each day. The
daily regression slopes were near unity (0.99 <inline-formula><mml:math id="M121" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.02) for the first
12 days; however, on the 13th day, comparisons showed that the 202-G analyzer
underestimated peak afternoon ambient ozone by <inline-formula><mml:math id="M122" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 8 % and the 202-G
continued to drop over the next 3 days, yielding a regression plot slope of
<inline-formula><mml:math id="M123" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 0.85 versus the 205-H. This is shown in Fig. 3c, where the slopes of
the daily comparison between the 202-G and 205-H are shown as a function of
the cumulative ozone exposure (in ppm h). The calibration of the 202-G was
rechecked and confirmed the scrubber only removed 86 <inline-formula><mml:math id="M124" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2 % of the
ozone passing through it.</p>
      <p>The graphite was regenerated by heating to 150 <inline-formula><mml:math id="M125" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for 1 h with
no ozone present, and the calibration slope returned to 1.01 <inline-formula><mml:math id="M126" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.02.
The 202-G was then returned to sampling, but the graphite scrubber was
maintained at 130 <inline-formula><mml:math id="M127" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C – the highest temperature without inducing
significant VOC emission from the graphite tubes as described in Sect. 3.1. Post-regeneration, the analyzers were compared again from 24 August to
30 September 2015 (38 days). Figure 3a shows a diurnal plot of the ozone
measured by the two analyzers on 26 September 2015, near the end of the
intercomparison. It is clear from this plot and the regression plot of the
same data in Fig. 3b that there was excellent agreement between the two
instruments. The daily intercomparison slope vs. ozone exposure in Fig. 3c
confirms there was no graphite scrubber efficiency loss after 38 days (or 30 ppm h
ozone exposure). A recheck of the analyzer calibrations found them to
be within the uncertainty of the initial calibrations. Subsequent
measurements using a dual-beam Model 211 equipped with a heated graphite
scrubber operating at 130 <inline-formula><mml:math id="M128" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C indicate that there is also no loss
in the ozone removal efficiency after exposure to 20 ppm h of ozone.
Therefore, it appears the graphite scrubber must be maintained at
temperatures greater than 100 <inline-formula><mml:math id="M129" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for reliable long-term continuous
monitoring. A temperature of 130 <inline-formula><mml:math id="M130" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C appears to be optimal for
maintaining the balance between oxidation of the graphite by ozone and the
loss of oxidized carbon from the surfaces to regenerate fresh carbon.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><caption><p><bold>(a)</bold> Time series of 5 min averaged ozone concentrations
measured in Boulder, CO, on 26 September 2015. <bold>(b)</bold> Correlation plot
between the Model 202 (202-G, equipped with graphite scrubber) and the FEM
Model 205 (205-H, Hopcalite scrubber and Nafion) for 26 September 2015.
<bold>(c)</bold> Plot of the daily correlation plot slope vs. cumulative ozone
exposure for the 202-G analyzer. Each point represents a single day. The
graphite scrubber was initially maintained at 100 <inline-formula><mml:math id="M131" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, regenerated,
and then operated at 130 <inline-formula><mml:math id="M132" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (see text for further explanation).
Triangles represent calibration slopes pre- and post-intercomparison.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f03.pdf"/>

        </fig>

<?xmltex \hack{\newpage}?>
</sec>
<sec id="Ch1.S3.SS3">
  <title>Interference testing</title>
      <p>As mentioned earlier, carbon-based scrubbers (typically charcoal or
activated carbon) remove ozone from air, but they also effectively remove
many other species such as VOCs and water and thus would introduce
interferences in ozone measurements. However, the more ordered planar
structure of graphite and the greatly reduced surface area provide fewer
sites for adsorption of interfering species. The results of our interference
testing described below were performed with the graphite scrubber heated to
100 <inline-formula><mml:math id="M133" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. Heating the graphite scrubber to 130 <inline-formula><mml:math id="M134" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (the
more optimal temperature found in our subsequent longevity testing described
in the previous section) would likely reduce adsorption of water, mercury,
and aromatic VOCs. Hence, these results can be viewed as a conservative
estimate of the expected behavior of the graphite scrubber in reducing
interferences in ozone measurements.</p>
<sec id="Ch1.S3.SS3.SSS1">
  <title>Water vapor</title>
      <p>Previous studies have shown that rapid humidity changes can cause large
apparent ozone absorptions (equivalent to tens of ppb) in most commercial
ozone analyzers (Kleindeinst et al., 1993; Wilson and Birks, 2006; Spicer et
al., 2010). Wilson and Birks (2006) explained this behavior as being due to
changes in the refractive index at the surface of the optical cell resulting
from varying amounts of water vapor adsorbed to cell walls. Initial
experiments with a Model 202 analyzer equipped with a conventional Hopcalite
scrubber, but no Nafion tube, indicated large signal changes coinciding with
changes in humidity (Fig. 4, black dashed line). A large positive
interference was observed as humidity was rapidly increased (uptake of water
by the scrubber) and an opposite negative interference seen upon changing
from humid to drier air (release of water from the scrubber). Figure 4
(magenta line) confirms that placement of a Nafion tube at the entrance to
the optical cell to equilibrate the humidity with surrounding air (same
humidity for <inline-formula><mml:math id="M135" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> effectively eliminates the water vapor
interference, as shown earlier by Wilson and Birks (2006). A drawback of
this approach is that Nafion tubing is expensive, and the length of tubing
required to attain adequate equilibration can place limits on its use in
miniaturized analyzers or can introduce flow restrictions, thus making it
impractical in some applications.</p>
      <p>The graphite scrubber proposed also mitigates artifacts caused by changing
water vapor concentrations. As seen in Fig. 4, the initial large change in
humidity does cause an apparent absorption of <inline-formula><mml:math id="M137" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 10 ppb of O<inline-formula><mml:math id="M138" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>
with the graphite scrubber in line. It appears that some water is initially
taken up by the graphite, likely due to the somewhat porous nature of the
graphite structure. However, water content within the graphite scrubber
equilibrates within about 2 min and returns to its original value, whereas
the Hopcalite trap remains compromised for &gt; 15 min. Subsequent
removal of the high water vapor concentration leads to a negative response as
water vapor desorbs from each scrubber. But again, the recovery of the
graphite scrubber is relatively rapid compared to the Hopcalite, so although
there is some water uptake, equilibration is rapid enough to exceed typical
humidity changes and 30–60 min ozone averages will be relatively
unaffected.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><caption><p>Time series showing the response of a Model 202 ozone analyzer to
changes in relative humidity with no ozone present and different scrubbers.</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f04.pdf"/>

          </fig>

      <p>Variation of relative humidity did indicate a slight water dependency in the
graphite scrubber and exhibited some differences between different graphite
tubes. Figure 5 illustrates this behavior, showing two different sets of
graphite tubes (four tubes in parallel, 7.6 cm long). Set #1 indicated about a
<inline-formula><mml:math id="M139" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>2.5 ppb change from dry to near-saturated air; whereas Set #2 was
essentially independent of the humidity. Given graphite's hydrophobic nature,
these differences are perplexing but could be due to differing degrees of
oxidation on the graphite surface or on binders within the graphite, making
the surface slightly more hydrophilic. The graphite scrubber's low
sensitivity to humidity was also confirmed in our ambient measurements
(Sect. 3.2), where we observed no correlation between ambient humidity changes
and concentration differences between the graphite-equipped Model 202-G and
the Hopcalite- and Nafion-equipped Model 205-H.</p>
</sec>
<sec id="Ch1.S3.SS3.SSS2">
  <title>Mercury</title>
      <p>Gaseous elemental mercury concentrations are typically less than a few ppt
in ambient air, but mercury poses a problem in ozone photometers because
typically the Hg atomic absorption line is used as the photometer's
excitation source (Hg line at 253.7 nm). Birks et al. (2009) estimate that
common ozone photometers could be 1860 times more sensitive to elemental
mercury than ozone (Selectivity <inline-formula><mml:math id="M140" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1.86 ppb O<inline-formula><mml:math id="M141" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg) depending on
how efficiently the scrubber removes mercury. Recent measurements in our
laboratory showed that mercury absorbs <inline-formula><mml:math id="M142" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1350 times more
strongly than ozone in the Model 202 Ozone Monitor using the packed-bed
Hopcalite scrubber (Birks, 2016, unpublished data). There is also evidence
suggesting that the efficiency of mercury uptake in several conventional
scrubbers may depend on humidity (U.S.-EPA, 1999; Spicer et al., 2010),
implying that these may act as a temporary reservoir capable of releasing
mercury at later times following humidity changes.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><caption><p>Humidity dependence of two different heated (100 <inline-formula><mml:math id="M143" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)
graphite scrubbers as well as that of a Hopcalite scrubber. The ozone
analyzer was a 2B Technologies Model 202 single-beam instrument. Data points
were 2 min averages obtained 15 min after a change in relative humidity.
Error bars are 1<inline-formula><mml:math id="M144" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> of the 2 min average. The experiment was conducted
at 20 <inline-formula><mml:math id="M145" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. Note that the step changes in humidity were not as large
as those shown in Fig. 4, thus leading to smaller observed artifact signals
for the Hopcalite scrubber.</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f05.pdf"/>

          </fig>

      <p>In order to examine possible interferences due to elemental mercury, varying
concentrations of mercury vapor were added to the Model 202 ozone monitor and
responses were monitored (in apparent ppb of ozone) while the various
graphite and conventional scrubbers were interchanged. As we did not have an
independent measurement of mercury vapor concentrations, all measurements
were made relative to the conventional packed-bed Hopcalite scrubber used in
the 2B Technologies analyzers. For different levels of mercury additions,
Fig. 6 shows the apparent ozone measured by the photometer as various
scrubbers were alternated with the packed-bed Hopcalite. Five different sets
of graphite tubes (a set is four tubes in parallel, each 7.6 cm long) were
tested, and the slopes of plots of apparent ozone concentration vs. those
obtained for the Hopcalite scrubber ranged from &lt; 0.01 to 0.03
(median set is shown in Fig. 6). One set showed no measurable response to
mercury up to an apparent ozone concentration of 2200 ppb for the Hopcalite
scrubber. Noting above our recent observation that mercury absorption is 1350 times
stronger than ozone (or 1.35 ppb O<inline-formula><mml:math id="M146" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg), this leads to a response
ratio of <inline-formula><mml:math id="M147" display="inline"><mml:mo>≤</mml:mo></mml:math></inline-formula> 0.04 ppb O<inline-formula><mml:math id="M148" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg for the graphite scrubber.
Measurements made at 22 and 80 % RH exhibited no differences (Fig. 6). In
addition, measurements made with and without Nafion tubing inserted before
the optical cell gave identical results, suggesting that mercury is neither
lost nor interacts significantly with Nafion.</p>
      <p><?xmltex \hack{\newpage}?>The heated silver wool scrubber exhibited the largest mercury response, with
a slope slightly greater than unity compared to Hopcalite (Fig. 6). Silver
is known to rapidly form an amalgam with mercury (Dumarey et al., 1985),
which likely explains this large response. Previous studies have shown that
both the 2B Technologies Hopcalite scrubber and heated silver wool scrubber
remove mercury vapor efficiently – reporting response ratios between 0.6 and
1.1 ppb O<inline-formula><mml:math id="M149" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg (Spicer et al., 2010; U.S.-EPA, 1999). We report a
response ratio of 1.49 ppb O<inline-formula><mml:math id="M150" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg for the heated silver wool,
assuming 1.35 ppb O<inline-formula><mml:math id="M151" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg for the Hopcalite scrubber – approximately
<inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> higher than the previous studies. The sensitivity to Hg depends on the
width of the emission line of the lamp (Birks et al., 2009), which may vary
from instrument to instrument.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><caption><p>Apparent ozone measured in the Model 202 single-beam ozone analyzer
using different ozone scrubbers, relative to the standard Hopcalite scrubber,
upon addition of mercury vapor to ozone-free air. Slopes are given by the
<inline-formula><mml:math id="M153" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> values. The graphite scrubbers were heated to 100 <inline-formula><mml:math id="M154" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for these
tests.</p></caption>
            <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f06.pdf"/>

          </fig>

      <p>Both the Teledyne API and Thermo Electron scrubbers used screens coated with
MnO<inline-formula><mml:math id="M155" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and showed less interference from mercury vapor compared to the
packed-bed Hopcalite scrubber (slopes of 0.18 and 0.065). This yields
response ratios of 0.24 and 0.09 ppb O<inline-formula><mml:math id="M156" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg for the Teledyne API and
Thermo Electron scrubbers, respectively. Smaller responses are likely due to
the large reduction in scrubber surface area by use of the coated screens.
Measurements made at both high (<inline-formula><mml:math id="M157" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 80 %) and low (20 %) relative
humidity showed no significant differences, although the considerable
scatter in the data likely obscures any small humidity dependencies. The
interference of mercury in ozone photometers with MnO<inline-formula><mml:math id="M158" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>-based scrubbers
has been the subject of several previous investigations. The U.S.-EPA (1999)
reported response ratios in the range of 0.12 to 0.24 ppb O<inline-formula><mml:math id="M159" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg using
a Thermo Electron scrubber. This study also suggested a lowering of the
response ratio with increasing humidity. Higher response ratios (0.87 and
0.6 ppb O<inline-formula><mml:math id="M160" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppt Hg) have also been reported in dry air (Li et al., 2006;
Spicer et al., 2010). Spicer et al. (2010) also reported that the response
ratio decreased by a factor of 2 when using humidified air (RH
<inline-formula><mml:math id="M161" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 80 %), which is closer to both our results and those of
the EPA. As will be shown for VOCs in the next section, it is likely that
even a small amount of water vapor can cause a significant change in the
adsorption properties of these solid-phase scrubbers; thus, the higher
response ratios determined in dry air may not be applicable to sampling of
ambient air. The use of a heated graphite scrubber can reduce the
interference in ozone photometers from mercury vapor by a factor of <inline-formula><mml:math id="M162" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 30 over the packed-bed Hopcalite scrubber and by a factor of <inline-formula><mml:math id="M163" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 2 over
the best solid-phase scrubber.</p>
      <p>This low response ratio is only matched by using the gas-phase nitric oxide
(NO) titration as a means of scrubbing ozone. In the recently introduced 2B
Technologies Model 211 Scrubberless Ozone Monitor<sup>™</sup>, gas-phase NO
titration eliminates the need for a solid-phase scrubber and effectively
eliminates interferences from both UV-absorbing species and water vapor
(Birks et al., 2013). However, a source gas of NO is required, reducing the
portability of the instrument and adding long-term cost. The heated graphite
scrubber avoids these disadvantages.</p>
      <p>In general, mercury is not expected to be a significant interference in
outdoor ambient air. Although there are some elevated measurements of
mercury vapor in urban areas of Asia (up to <inline-formula><mml:math id="M164" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 3 ppt: Fang et
al., 2004; Liu et al., 2002; Kim and Kim, 2002), concentrations typically
range from 0.2 (background) to 0.5 (urban) ppt (Obrist et al., 2008;
Weiss-Penzias et al., 2003; Denis et al., 2006). However, gas-phase mercury
can reach higher levels near industrial or mining sources. Elevated mercury
levels have also been shown to be present for indoor air (Carpi and Chen,
2001; Garetano et al., 2006). Because indoor ozone concentrations are
typically low (<inline-formula><mml:math id="M165" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 20–80 % of outdoor air, U.S. EPA, 2016),
mercury poses a larger potential problem for indoor air quality monitoring
of ozone. For example, Carpi and Chen (2001) report indoor mercury
concentrations of up to 520 ng m<inline-formula><mml:math id="M166" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (<inline-formula><mml:math id="M167" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 63 ppt). This would
correspond to measured absorbances equivalent to <inline-formula><mml:math id="M168" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 ppb O<inline-formula><mml:math id="M169" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> with the packed-bed Hopcalite, <inline-formula><mml:math id="M170" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 6–15 ppb O<inline-formula><mml:math id="M171" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> with
conventional MnO<inline-formula><mml:math id="M172" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> screens, and &lt; 2.6 ppb O<inline-formula><mml:math id="M173" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> using the
heated graphite.</p>
</sec>
<sec id="Ch1.S3.SS3.SSS3">
  <title>Volatile organic compounds (VOCs)</title>
      <p>Interferences from volatile organic compounds are more complicated due to
the wide variety of compounds and their properties. There are many diverse
atmospheric VOCs having a wide range of 253.7 nm absorption cross sections,
volatilities, and potential responses to humidity. Along with the VOC
absorption cross sections, Table 1 also lists room temperature vapor
pressures as an indicator of volatility. Aromatic VOCs are the most
important when discussing interferences in ozone monitors, since the
conjugation between the carbon–carbon double bonds both shifts the
absorption spectrum to longer wavelengths and results in larger UV cross
sections. Addition of various functional groups (hydroxyl, aldehyde, nitro,
etc.) to the aromatic ring can further increase the absorption cross
section. Furthermore, substitutions often result in lower volatility, making
these species more likely to be retained in a solid-phase scrubber.</p>
      <p>Interferences from VOCs typically result from two different mechanisms: (1) adsorption of the compound by the scrubber, resulting in a positive bias, and
(2) subsequent later desorption of that compound from the scrubber due to
eventual elution and/or changes in temperature or humidity that yield a
negative bias. These two processes are complex functions of environmental
conditions (temperature and humidity), volatility, and chemical properties of
the specific VOC, as well as the reactivity and surface area of the scrubber
material.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7" specific-use="star"><caption><p>Apparent ozone vs. VOC concentration in dry, ozone-free air for
different scrubber types and four different VOCs of varying absorption cross
section at 253.7 nm. Data from two different sets of graphite tubes are
shown (Set #1 and Set #2). Slopes are given in
Table 2.</p></caption>
            <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f07.pdf"/>

          </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><caption><p>Summary of results from tests of VOC interferences in dry
air.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Volatile organic</oasis:entry>  
         <oasis:entry colname="col2">Scrubber</oasis:entry>  
         <oasis:entry colname="col3">Slope,</oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math id="M179" display="inline"><mml:mrow><mml:msup><mml:mi>S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula>,</oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math id="M180" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>, previous</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">compound</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">ppb O<inline-formula><mml:math id="M181" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppb,VOC</oasis:entry>  
         <oasis:entry colname="col4">ppb VOC/ppb O<inline-formula><mml:math id="M182" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col5">results</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M183" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-Xylene</oasis:entry>  
         <oasis:entry colname="col2">2B Hopcalite</oasis:entry>  
         <oasis:entry colname="col3">0.056 <inline-formula><mml:math id="M184" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.004</oasis:entry>  
         <oasis:entry colname="col4">17.9</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Thermo Electron (MnO<inline-formula><mml:math id="M185" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.051 <inline-formula><mml:math id="M186" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.003</oasis:entry>  
         <oasis:entry colname="col4">19.6</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Teledyne API (MnO<inline-formula><mml:math id="M187" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>.)</oasis:entry>  
         <oasis:entry colname="col3">0.046 <inline-formula><mml:math id="M188" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.005</oasis:entry>  
         <oasis:entry colname="col4">21.7</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Heated graphite</oasis:entry>  
         <oasis:entry colname="col3">0.012 <inline-formula><mml:math id="M189" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.001</oasis:entry>  
         <oasis:entry colname="col4">83.3</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Phenol</oasis:entry>  
         <oasis:entry colname="col2">2B Hopcalite</oasis:entry>  
         <oasis:entry colname="col3">0.21 <inline-formula><mml:math id="M190" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.01</oasis:entry>  
         <oasis:entry colname="col4">4.76</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Thermo Electron (MnO<inline-formula><mml:math id="M191" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.18 <inline-formula><mml:math id="M192" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.01</oasis:entry>  
         <oasis:entry colname="col4">5.56</oasis:entry>  
         <oasis:entry colname="col5">7.7–14.3<inline-formula><mml:math id="M193" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Teledyne API (MnO<inline-formula><mml:math id="M194" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">0.20 <inline-formula><mml:math id="M195" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.01</oasis:entry>  
         <oasis:entry colname="col4">5.00</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Heated graphite</oasis:entry>  
         <oasis:entry colname="col3">0.051 <inline-formula><mml:math id="M196" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.004</oasis:entry>  
         <oasis:entry colname="col4">19.6</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M197" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-Tolualdehyde</oasis:entry>  
         <oasis:entry colname="col2">2B Hopcalite</oasis:entry>  
         <oasis:entry colname="col3">1.71 <inline-formula><mml:math id="M198" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.25</oasis:entry>  
         <oasis:entry colname="col4">0.58</oasis:entry>  
         <oasis:entry colname="col5">0.0–2.0<inline-formula><mml:math id="M199" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Thermo Electron (MnO<inline-formula><mml:math id="M200" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">1.57 <inline-formula><mml:math id="M201" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.43</oasis:entry>  
         <oasis:entry colname="col4">0.63</oasis:entry>  
         <oasis:entry colname="col5">1.25<inline-formula><mml:math id="M202" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Teledyne API (MnO<inline-formula><mml:math id="M203" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">1.54 <inline-formula><mml:math id="M204" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.10</oasis:entry>  
         <oasis:entry colname="col4">0.65</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Heated graphite</oasis:entry>  
         <oasis:entry colname="col3">0.08 <inline-formula><mml:math id="M205" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.02</oasis:entry>  
         <oasis:entry colname="col4">12.5</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">0.28 <inline-formula><mml:math id="M206" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.06<inline-formula><mml:math id="M207" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">d</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">3.6</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math id="M208" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-Nitrophenol</oasis:entry>  
         <oasis:entry colname="col2">2B Hopcalite</oasis:entry>  
         <oasis:entry colname="col3">7.7 <inline-formula><mml:math id="M209" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.5</oasis:entry>  
         <oasis:entry colname="col4">0.13</oasis:entry>  
         <oasis:entry colname="col5">0.55–0.91<inline-formula><mml:math id="M210" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Thermo Electron (MnO<inline-formula><mml:math id="M211" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">8.0 <inline-formula><mml:math id="M212" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.3</oasis:entry>  
         <oasis:entry colname="col4">0.13</oasis:entry>  
         <oasis:entry colname="col5">0.45<inline-formula><mml:math id="M213" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Teledyne API (MnO<inline-formula><mml:math id="M214" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">7.4 <inline-formula><mml:math id="M215" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.3</oasis:entry>  
         <oasis:entry colname="col4">0.14</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2">Heated graphite</oasis:entry>  
         <oasis:entry colname="col3">1.1 <inline-formula><mml:math id="M216" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.3</oasis:entry>  
         <oasis:entry colname="col4">0.91</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">2.7 <inline-formula><mml:math id="M217" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.2<inline-formula><mml:math id="M218" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">d</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">0.37</oasis:entry>  
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p><inline-formula><mml:math id="M174" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula> <inline-formula><mml:math id="M175" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo></mml:mrow></mml:math></inline-formula> slope, measured selectivity ratio.
<inline-formula><mml:math id="M176" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula> Zdanevitch (2002). <inline-formula><mml:math id="M177" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula> Spicer et al. (2010).
<inline-formula><mml:math id="M178" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">d</mml:mi></mml:msup></mml:math></inline-formula> Results from two different sets of graphite tubes.</p></table-wrap-foot></table-wrap>

      <p>Past studies of VOC interferences have typically been of three types: (1) measurement of total net ozone biases during irradiation of simulated
atmospheres in smog chambers (Kleindeist et al., 1993; Leston et al., 2005),
(2) simultaneous atmospheric measurements by different analyzers using
different measurement techniques (Ollison et al., 2013; Dunlea et al.,
2006), and (3) addition of selected VOCs to ozone analyzers to determine the
interference from that particular VOC (Grosjean and Harrison, 1985; Spicer
et al., 2010). All of these approaches contribute to our understanding of
the significance of VOC interferences in ozone monitors; however, we have
chosen the latter approach to initially evaluate our heated graphite
scrubber because it is a more direct approach and reproducible signals can
be easily quantified. We chose <inline-formula><mml:math id="M219" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene, phenol, <inline-formula><mml:math id="M220" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde, and
<inline-formula><mml:math id="M221" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol as test VOCs since they have reported 253.7 nm absorption
cross sections ranging from <inline-formula><mml:math id="M222" display="inline"><mml:mrow><mml:mn mathvariant="normal">5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M223" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene) to <inline-formula><mml:math id="M224" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.15</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M225" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol) cm<inline-formula><mml:math id="M226" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molecule<inline-formula><mml:math id="M227" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Keller-Rudek
et al., 2013) and vapor pressures (25 <inline-formula><mml:math id="M228" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) of 0.11 to 8.8 mm Hg.</p>
</sec>
</sec>
<sec id="Ch1.S3.SSx1" specific-use="unnumbered">
  <title>VOC interferences in dry air</title>
      <p>Initial experiments
examined VOC interferences in dry air (RH &lt; 3 %) in the absence
of ozone using a single-beam Model 202 monitor equipped with the various
scrubbers described above. No Nafion tubing was installed upstream of the
optical cell in the monitor. VOC concentrations were measured by sampling the
same air stream into the inlet of a GC-FID. Upon VOC addition, apparent ozone
absorbances were observed to reach steady values within the initial 2–4 min
with both the Hopcalite and MnO<inline-formula><mml:math id="M229" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>-based scrubbers. With the heated
graphite scrubber, there was a rapid increase in apparent ozone upon
addition, followed by a decay to steady values after 3 min. Average apparent
ozone concentrations were obtained after 5 min of exposure and plotted vs.
VOC concentrations measured with the GC-FID (Fig. 7). There were no signs of
surface saturation effects, as indicated by the linearity of the apparent
ozone with VOC concentration plots. For all the compounds tested, the heated
graphite scrubbers showed less apparent ozone. The slopes of the plots in
Fig. 7 are given in Table 2. In all cases, the slopes were a factor of 2.5 to
20 less for the graphite scrubber than for Hopcalite or the MnO<inline-formula><mml:math id="M230" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
scrubbers, indicating greatly reduced VOC uptake by the graphite. Data from
two sets of graphite tubes (four tubes in parallel) gave identical results
for both <inline-formula><mml:math id="M231" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene and phenol; however, both <inline-formula><mml:math id="M232" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde and
<inline-formula><mml:math id="M233" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol exhibited slightly different apparent ozone values from these
two different sets of graphite tubes. Responses for three other sets of
graphite tubes were also tested against the Hopcalite scrubber and gave
absorbances within the range of those shown in the figure. It remains unclear
why different tube sets show slightly different behavior, but, again, it
likely lies in the degree of graphite surface oxidation.</p>
      <p>In dry air both Hopcalite and MnO<inline-formula><mml:math id="M234" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> scrubbers exhibited similar
responses for all the compounds tested. If the scrubbers remove 100 % of
the VOC compound, then the slope of these plots should be the inverse of the
selectivity ratio reported in Table 1:
            <disp-formula id="Ch1.E2" content-type="numbered"><mml:math id="M235" display="block"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mi>S</mml:mi></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mi mathvariant="normal">Slope</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mrow class="chem"><mml:mi mathvariant="normal">VOC</mml:mi></mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">254</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">254</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mspace width="1em" linebreak="nobreak"/><mml:mo>(</mml:mo><mml:mtext>in ppb</mml:mtext><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>/</mml:mo><mml:mi mathvariant="normal">ppb</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">VOC</mml:mi><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          There is good agreement in the theoretical slope and that observed for
<inline-formula><mml:math id="M236" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene (see Table 2), suggesting both Hopcalite and MnO<inline-formula><mml:math id="M237" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>-based
scrubbers effectively scavenge all of the <inline-formula><mml:math id="M238" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene in dry air. However, the
slopes for phenol, <inline-formula><mml:math id="M239" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde, and <inline-formula><mml:math id="M240" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol were all significantly
higher by factors of 1.4, 3.3, and 4.1, respectively, than those computed
from previously reported absorption cross sections. As this would require
&gt; 100 % removal by the scrubber, this can only be explained
either by errors in the previously reported VOC cross sections or by an
underestimation in the VOC concentrations via the GC technique. Since the
error tends to decrease with volatility, the latter is more likely as it
becomes more difficult to quantitatively desorb the VOC from the Tenax
pre-concentration trap used in the GC. Furthermore, if our <inline-formula><mml:math id="M241" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol
concentrations were correct, this suggests a 253.7 nm absorption cross
section of nearly <inline-formula><mml:math id="M242" display="inline"><mml:mrow><mml:mn mathvariant="normal">9</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math id="M243" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molecule<inline-formula><mml:math id="M244" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, which
seems inexplicably large.</p>
      <p>We did not pursue a more accurate GC-FID VOC quantitation, as the heated
graphite scrubber can still be assessed on a relative basis to the
conventional scrubbers from the ratios of the slopes in Fig. 7. Assuming
that the packed-bed Hopcalite scrubber exhibits the theoretical selectivity
factor based on absorption cross sections for each VOC tested (reported in
Table 1), selectivity ratios of 83, 28, <inline-formula><mml:math id="M245" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 12, and <inline-formula><mml:math id="M246" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 1.5 ppb VOC/ppb O<inline-formula><mml:math id="M247" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> were estimated for <inline-formula><mml:math id="M248" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene, phenol, <inline-formula><mml:math id="M249" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde, and
<inline-formula><mml:math id="M250" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol, respectively, for the heated graphite scrubber. In other
words, it would require a <inline-formula><mml:math id="M251" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene concentration of 83 ppb to produce a
signal of 1 ppb O<inline-formula><mml:math id="M252" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> in an analyzer using a heated graphite scrubber
compared to a concentration of 20 ppb for the Hopcalite or MnO<inline-formula><mml:math id="M253" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
scrubbers.</p>
      <p>We observed less than a 10 % difference between the response ratios obtained
with the Hopcalite and the two MnO<inline-formula><mml:math id="M254" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> thin-film screen scrubbers for both
<inline-formula><mml:math id="M255" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde and <inline-formula><mml:math id="M256" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol in dry air. Spicer et al. (2010) report
values of 0.8 and 0.0 to 0.5 ppb O<inline-formula><mml:math id="M257" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppb <inline-formula><mml:math id="M258" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde in dry air when
using the MnO<inline-formula><mml:math id="M259" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and Hopcalite scrubbers, respectively, which is a difference of
<inline-formula><mml:math id="M260" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 30 %. They also report values of 2.2 and 1.1 to 1.8 ppb O<inline-formula><mml:math id="M261" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppb <inline-formula><mml:math id="M262" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol for the MnO<inline-formula><mml:math id="M263" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and Hopcalite scrubbers. This leads to
differences ranging from 20 % to a factor of 2, contrary to that
observed in the current study. However, concentration levels of interfering
VOCs were quite low in the Spicer et al. (2010) study, ranging from 7.6 to
14 ppb, and their measured apparent ozone mixing ratios were &lt;15
ppb. At these levels, small signal drifts, or the typical precision of
<inline-formula><mml:math id="M264" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>1 to 2 ppb in the ozone analyzers, impart significant uncertainty in
the measured response ratio. It should be noted that the value of 0.8 ppb O<inline-formula><mml:math id="M265" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/ppb <inline-formula><mml:math id="M266" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde reported in Spicer et al. (2010) for the
MnO<inline-formula><mml:math id="M267" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> scrubber is also above the maximum theoretical response based on
the reported absorption cross sections by a factor of 1.7 (<inline-formula><mml:math id="M268" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.48</mml:mn></mml:mrow></mml:math></inline-formula>,
Table 1).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><caption><p><bold>(a)</bold> Plot of the temporal behavior of the apparent ozone at
38 % RH as 1.2 ppm of <inline-formula><mml:math id="M269" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene is added (<inline-formula><mml:math id="M270" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> min) and then
removed (<inline-formula><mml:math id="M271" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">15</mml:mn></mml:mrow></mml:math></inline-formula> min) from ozone-free air for various scrubbers. Inset:
temporal decay of the fractional apparent ozone ([O<inline-formula><mml:math id="M272" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M273" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi mathvariant="normal">o</mml:mi></mml:msub><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> initial concentration) as a function of relative humidity upon addition
of <inline-formula><mml:math id="M274" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1.3 ppm of <inline-formula><mml:math id="M275" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene to a Model 202 analyzer equipped with a
packed-bed Hopcalite scrubber. <bold>(b)</bold> Temporal behavior of the apparent
ozone at 75 % RH as <inline-formula><mml:math id="M276" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 90 ppb of <inline-formula><mml:math id="M277" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde was added (<inline-formula><mml:math id="M278" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> min) and then removed (<inline-formula><mml:math id="M279" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">30</mml:mn></mml:mrow></mml:math></inline-formula> min) for various
scrubbers.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f08.pdf"/>

        </fig>

      <p>Zdanevitch (2002) reported a higher response for phenol and other VOCs
studied with ozone present and suggested that photochemical production of
stronger-absorbing compounds within the optical cell may be responsible. Our
experiments with <inline-formula><mml:math id="M280" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde and <inline-formula><mml:math id="M281" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene failed to show such evidence
for photochemical behavior. Absorbances recorded with both ozone and VOCs
present were equivalent to the sum of the absorbances when these components
were measured individually within the precision of the analyzer. This
supports calculations that suggest negligible photochemistry can occur due
to the low photon flux and short residence time in the 2B Technologies Model 202.</p>
</sec>
<sec id="Ch1.S3.SSx2" specific-use="unnumbered">
  <title>VOC interferences in humid air</title>
      <p>Even at low humidity
levels, water vapor is adsorbed to some extent by most of the conventional
solid-phase scrubbers. This changes the surface characteristics of the solid
phase, which, in turn, can alter the adsorption and desorption of other
compounds. This is also dependent upon the properties of the species of
interest – especially the particular compound's volatility. For the most
volatile compound studied, <inline-formula><mml:math id="M282" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene, even low levels of humidity caused the
observed interference (apparent ozone) to decrease over time. Figure 8a shows
the temporal behavior of the apparent ozone absorption upon addition of
<inline-formula><mml:math id="M283" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1 ppm of <inline-formula><mml:math id="M284" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene in moderately humid ozone-free air with an
analyzer equipped with a conventional packed-bed Hopcalite scrubber and
Nafion. There is an initial spike in the signal that then decays over time.
The inset of Fig. 8a shows how this decay varied as a function of RH. In each
case, <inline-formula><mml:math id="M285" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene was added to generate an apparent ozone signal of
<inline-formula><mml:math id="M286" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 80 ppb in dry air. The humidity was then changed within 20 seconds,
and the absorbance decay was recorded. The apparent ozone decay was faster at
higher humidity, suggesting that the presence of water causes less <inline-formula><mml:math id="M287" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene
to be retained in the scrubber.</p>
      <p>However, even at these higher water vapor concentrations, the scrubber still
accumulated <inline-formula><mml:math id="M288" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene. This is apparent upon turning off the <inline-formula><mml:math id="M289" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene source,
as a large negative absorbance was then observed (Fig. 8a). <inline-formula><mml:math id="M290" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-Xylene was
now slowly desorbing from the scrubber material, thus absorbing more light
during the <inline-formula><mml:math id="M291" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurement relative to <inline-formula><mml:math id="M292" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>. This slow emission was also
humidity dependent – becoming faster at higher relative humidity (data not
shown). Scrubbers from the Thermo Electron and Teledyne API instruments show
similar behavior, except that the time response is much faster (&lt; 2 min, Fig. 8a), presumably due to the lower surface area of scrubber
material. In fact, these scrubbers were observed to pass <inline-formula><mml:math id="M293" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene nearly
quantitatively, similar to the graphite scrubber after about 5 min as
long as RH &gt; 10 %. These scrubbers also showed rapid release of
the <inline-formula><mml:math id="M294" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene once the VOC exposure was discontinued. However, the
equilibration is rapid enough that, even at low humidity, the effect of
xylenes on hourly averaged ambient ozone measurements is likely negligible
with these low surface area scrubbers.</p>
      <p>VOC responses with the heated graphite scrubber tend to be relatively
insensitive to changes in relative humidity. Figure 9 shows a 1 ppm <inline-formula><mml:math id="M295" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene
addition to an ozone analyzer initially equipped with a Hopcalite scrubber
at low RH (9 %), giving an apparent O<inline-formula><mml:math id="M296" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> concentration of 67 ppb. The
Hopcalite was then exchanged for a heated graphite scrubber, and the relative
humidity varied over the following 95 min where there is little to no
RH-driven change in the observed absorbance. A plot of the averaged signal
versus relative humidity yields a slope of 0.018 ppb apparent O<inline-formula><mml:math id="M297" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>/%
RH, where a humidity change from 20 to 80 % only alters the apparent ozone
signal from 1 ppm of <inline-formula><mml:math id="M298" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene by <inline-formula><mml:math id="M299" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>1 ppb.</p>
      <p>As the VOC becomes less volatile, the advantages of the heated graphite
scrubber become more significant. Experiments with <inline-formula><mml:math id="M300" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde indicated
that a small amount of humidity (RH <inline-formula><mml:math id="M301" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 22 %) did not alter the behavior
from that observed in dry air for any of the various scrubbers. However, as
RH increased to 75 %, the coated MnO<inline-formula><mml:math id="M302" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> screen scrubbers showed a large
increase, followed by a slow decay over 20–30 min (Fig. 8b) –
a behavior akin to the packed-bed Hopcalite–<inline-formula><mml:math id="M303" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene exposure discussed
previously. These scrubbers also exhibited a larger negative absorbance when
the <inline-formula><mml:math id="M304" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde flow was removed, indicating release of adsorbed
<inline-formula><mml:math id="M305" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde post-exposure, similar to the Hopcalite–<inline-formula><mml:math id="M306" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene temporal
profiles. For phenol, the selectivity for both the Hopcalite and MnO<inline-formula><mml:math id="M307" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
scrubbers remained constant regardless of humidity (data not shown). Even at
RH <inline-formula><mml:math id="M308" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 75 %, the Hopcalite and MnO<inline-formula><mml:math id="M309" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> scrubbers behaved similar to dry
air, quantitatively removing phenol and showing no decay in the apparent
O<inline-formula><mml:math id="M310" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> absorbance over at least 10 min. We did not examine the behavior
of <inline-formula><mml:math id="M311" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol with humidity, but presume it would be similar to that of
phenol.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><caption><p>Apparent ozone observed upon addition of <inline-formula><mml:math id="M312" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1.3 ppm of
<inline-formula><mml:math id="M313" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene to ozone-free air. Initially, the ozone analyzer was equipped with
the standard Hopcalite scrubber (apparent O<inline-formula><mml:math id="M314" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>
concentration <inline-formula><mml:math id="M315" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 67 ppb). The Hopcalite was replaced with the heated
graphite scrubber at time <inline-formula><mml:math id="M316" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 5 min. Over the next 95 min, the relative
humidity of the air was varied as designated by the red vertical dashed
lines.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/10/2253/2017/amt-10-2253-2017-f09.pdf"/>

        </fig>

      <p>Although the conventional MnO<inline-formula><mml:math id="M317" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> scrubbers with low surface area appear
to be compatible with the more volatile aromatics like xylene, their
propensity to have uptake and re-emission of less volatile compounds
dependent upon humidity levels is problematic in estimating ozone monitor
biases. The selectivity ratio described above is now a function of humidity
which varies in time. The wide variety of different atmospheric VOCs and
their varying properties suggest that it will be nearly impossible to
quantitatively model or estimate whether these scrubbers are consuming or
releasing compounds, i.e., whether ozone monitors are biased negatively or
positively. For example, Spicer et al. (2010) reported a decrease in the
percent response ratio for the MnO<inline-formula><mml:math id="M318" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> scrubber from 0.8 to 0.1 ppb <inline-formula><mml:math id="M319" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde/ppb O<inline-formula><mml:math id="M320" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> going from dry to humid air. This lowering of the
<inline-formula><mml:math id="M321" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde absorbance with RH was also observed in this study but was
dependent upon exposure time such that a single selectivity ratio cannot be
used. In contrast to the conventional solid-phase scrubbers, VOC
interferences observed with the heated graphite scrubber are virtually
insensitive to humidity changes for all the compounds studied. Although the
graphite scrubber does retain a small fraction of the VOCs, the lack of a
humidity dependence makes potential ozone monitor biases easier to predict.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <title>Conclusions</title>
      <p>A new solid-phase scrubber based on graphite for use in conventional ozone
photometers was investigated and found to effectively remove ozone, while
offering significant advantages over current ozone scrubbers with regard to
species that typically interfere in ozone measurements. When heated to
100–130 <inline-formula><mml:math id="M322" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, the graphite scrubber quantitatively removed ozone up
to 500 ppb – well above the concentration levels required for most ambient
or indoor monitoring studies. After 2 weeks of ambient measurements in a
single-beam instrument, slow oxidation of the graphite surface reduced its
ability to completely remove ozone when operated at the lower end of the
temperature range studied (<inline-formula><mml:math id="M323" display="inline"><mml:mo>≤</mml:mo></mml:math></inline-formula> 100 <inline-formula><mml:math id="M324" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C). However, when operated
at 130 <inline-formula><mml:math id="M325" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, no loss of ozone removal efficiency was observed up to
exposures of 30 ppm h over 38 days, and agreement with a conventional FEM
analyzer was excellent throughout the time period. The higher temperature
likely facilitates removal of lower-reactivity oxidized species from the
graphite surface either by enhancing desorption or the reaction rate with
ozone. Therefore, long-term measurements require continuous operation near
the maximum of 130 <inline-formula><mml:math id="M326" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C or periodic regeneration of the scrubber by
heating it to 150 <inline-formula><mml:math id="M327" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for 20–30 min. These conditions appear to
be valid for both single-beam and dual-beam monitors.</p>
      <p>The major advantage of the heated graphite scrubber is its ability to pass
many of the known atmospheric interferences that plague conventional
solid-phase ozone scrubbers. Elimination of small biases of a few ppb of
ozone can be critical in marginal compliance situations where ambient ozone
is near the NAAQS. Water effects on ozone measurements (through refractive
index changes in the optical cell) were virtually eliminated by use of the
graphite scrubber, thereby eliminating the need for humidity equilibration
using Nafion. Gas-phase mercury interference was <inline-formula><mml:math id="M328" display="inline"><mml:mo>≤</mml:mo></mml:math></inline-formula> 3 % of a
packed-bed Hopcalite scrubber and at least a factor of 2 better than
other conventional MnO<inline-formula><mml:math id="M329" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> coated-screen scrubbers. The graphite scrubber
was also observed to consistently exhibit smaller interferences in dry air
for a series of substituted aromatic compounds ranging in volatility and
extinction coefficient. The apparent ozone absorptions measured with the
graphite scrubber were typically a factor of 2.5 to 20 smaller than those
with the conventional Hopcalite or MnO<inline-formula><mml:math id="M330" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> scrubbers. Our results suggest
that to generate an absorbance equivalent to 1 ppb of ozone would
necessitate concentrations of 83 ppb of <inline-formula><mml:math id="M331" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene, 28 ppb of phenol, <inline-formula><mml:math id="M332" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 12 ppb of <inline-formula><mml:math id="M333" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde, <inline-formula><mml:math id="M334" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 1.5 ppb of <inline-formula><mml:math id="M335" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-nitrophenol, or <inline-formula><mml:math id="M336" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 25 ppt
of mercury vapor. These are nearly 3 or more times greater than typical
ambient concentrations for any of these species (Table 1).</p>
      <p>The small VOC interference observed with the graphite scrubber was also
insensitive to humidity level. Although the conventional commercial
solid-phase scrubbers tended to remove all of the aromatic VOCs studied in
dry air, these scrubbers tended to show less interferences at higher
humidity levels (i.e., less aromatic compounds retained in the scrubber).
This lowering of the interference was tied to the particular VOC's intrinsic
volatility and the surface area of the solid-phase scrubber. Low-volatility
compounds (such as phenol) were retained regardless of humidity level,
whereas compounds with higher volatility (<inline-formula><mml:math id="M337" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-xylene) were nearly
quantitatively passed by the scrubbers using coated screens with low surface
area. For compounds that were intermediate in volatility, such as
<inline-formula><mml:math id="M338" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde, the conventional commercial scrubbers quantitatively removed
the VOC at low humidity (&lt; 40 % RH), but the coated-screen
scrubbers showed a slow equilibration at high water vapor concentrations
(&gt; 70 % RH, <inline-formula><mml:math id="M339" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">equil</mml:mi></mml:msub><mml:mo>∼</mml:mo></mml:mrow></mml:math></inline-formula> 30 min.). These also
released <inline-formula><mml:math id="M340" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-tolualdehyde upon ending exposure to the compound. These results
strongly suggest that these scrubbers tend to accumulate VOCs under drier
conditions (creating a positive bias in ozone analyzers) and then
subsequently rerelease them as humidity is increased (creating the
possibility of a negative bias). This complex behavior involving humidity
and volatility is avoided by use of the heated graphite scrubber.</p>
      <p>Although more work is needed to determine whether the graphite scrubber can
replace conventional solid-phase scrubbers for long-term compliance
monitoring, both the lab and field studies presented here suggest that the
heated graphite scrubber has the potential to provide more accurate ozone
concentration measurements by reducing conventional photometer
susceptibility to many common interferences. The operating characteristics
(flow, pressure, etc.) of the heated graphite scrubber are also compatible
with most conventional ozone monitors. Reducing interferences in ozone
measurements is especially important for ozone monitoring in highly polluted
regions or in applications where high levels of VOCs or mercury exist, such
as in smog chamber experiments, indoor environments, or near areas of
mercury contamination. It may also prove to be important in areas of
marginal noncompliance with ambient ozone standards.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability">

      <p>Experimental data presented here are available upon request
to the authors (andrewt@twobtech.com).</p>
  </notes><notes notes-type="competinginterests">

      <p>All authors are employees of 2B Technologies, Inc., which
produces commercial UV-absorbance ozone monitors including the instruments
used in this work.</p>
  </notes><ack><title>Acknowledgements</title><p>The authors would like to acknowledge John Ortega at the National Center
for Atmospheric Research for assistance with GC-FID measurements. We would
also like to thank Will Ollison for his advice and critique of this
manuscript.<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>
Edited by: T. F. Hanisco<?xmltex \hack{\newline}?>
Reviewed by: two anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>
Avnery, S., Mauzerall, D. L., Liu, J., and Horowitz, L. W.: Global crop yield
reductions due to surface ozone exposure: 1. Year 2000 crop production losses
and economic damage, Atmos. Environ., 45, 2284–2296, 2011.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>
Bernardo-Bricker, A., Farmer, C. Milne, P., Riemer, D., Zika, R., and
Stoneking, C.: Validation of speciated nonmethane hydrocarbon compound data
collected during the 1992 Atlanta Intensive as part of the Southern Oxidants
Study, J. Air Waste Manage., 45, 591–603, 1995.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>
Birks, J. W., Williford, C. J., and Andersen, P. C.: Use of a Broad Band UV
Light Source for Reducing the Mercury Interference in Ozone Measurements,
U.S. Patent Application US 2009/0302230 A1, US Patent and Trademark Office,
Washington, D.C., USA, 2009.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>
Birks, J. W., Andersen, P. C., and Williford, C. J.: Ozone monitor with
gas-phase scrubber, U.S. Patent US 8,395,776 B2, US Patent and Trademark
Office, Washington, D.C., USA, 2013.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>
Birks, J. W., Turnipseed, A. A., Andersen, P. C., and Williford, C. J.:
Heated Graphite Scrubber to Reduce Interferences in Ozone Monitors, U.S.
Patent US 2016/0025696 A1, US Patent and Trademark Office, Washington, D.C.,
USA, 2016.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Burkholder, J. B., Sander, S. P., Abbatt, J., Barker, J. R., Huie, R. E.,
Kolb, C. E., Kurylo, M. J., Orkin, V. L., Wilmouth, D. M., and Wine, P. H.:
Chemical Kinetics and Photochemical Data for Use in Atmospheric Studies,
Evaluation No. 18, JPL Publication 15-10, Jet Propulsion Laboratory,
Pasadena, USA, 2015.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>
Burnett, R. T., Brook, J. R., Yung, W. T., Dales, R. E., and Krewski, D.:
Association between ozone and hospitalization for respiratory diseases in
16 Canadian cities, Environ. Res., 72, 24–31, 1997.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
Carpi, A. and Chen, Y. F.: Gaseous elemental mercury as an indoor air
pollutant, Environ. Sci. Technol., 35, 4170–4173, 2001.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Chameides, W. L. and Walker, J. C. G.: A photochemical theory of tropospheric
ozone, J. Geophys. Res., 78, 8751–8759, 1973.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>
Davies, L.: Nitrobenzene, International Programme on Chemical Safety –
Environmental Health Criteria 230, World Health Organization, Geneva,
Switzerland, 2003.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Delhomme, O., Morville, S., and Millet, M.: Seasonal and diurnal variations
of atmospheric concentrations of phenols and nitrophenols measured in the
Strasborg area, France, Atmos. Pollut. Res., 1, 16–22, 2010.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>
Denis, M. St., Song, X., Lu, J. Y., and Feng, X.: Atmospheric gaseous
elemental mercury in downtown Toronto, Atmos. Environ, 40, 4016–4024, 2006.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>
Dumarey, R., Dams, R., and Hoste, J.: Comparison of the collection and
desorption efficiency of activated charcoal, silver and gold for the
determination of vapor-phase atmospheric mercury, Anal. Chem., 57,
2638–2644, 1985.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>Dunlea, E. J., Herndon, S. C., Nelson, D. D., Volkamer, R. M., Lamb, B. K.,
Allwine, E. J., Grutter, M., Ramos Villegas, C. R., Marquez, C., Blanco, S.,
Cardenas, B., Kolb, C. E., Molina, L. T., and Molina, M. J.: Technical note:
Evaluation of standard ultraviolet absorption ozone monitors in a polluted
urban environment, Atmos. Chem. Phys., 6, 3163–3180,
<ext-link xlink:href="https://doi.org/10.5194/acp-6-3163-2006" ext-link-type="DOI">10.5194/acp-6-3163-2006</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>Eiguren-Fernandez, A., Miguel, A. H., Foines, J. R., Thurairatnam, S., and
Avol, E. L.: Seasonal and spatial variation of polycyclic aromatic
hydrocarbons in vapor-phase and PM<inline-formula><mml:math id="M341" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> in Southern California urban and
rural communities, Aerosol Sci. Tech., 38, 447–455, 2004.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>
Ellis, W. D. and Tometz, P. V.: Room-temperature catalytic decomposition of
ozone, Atmos. Environ., 6, 707–714, 1972.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Emberson, L., Ashmore, M., and Murray, F.: Air Pollution Impacts on Crops and
Forests. A Global Assessment, Imperial College Press, London, UK, 2003.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
Emberson, L. D., Büker, P., Ashmore, M. R., Mills, G., Jackson, L. S.,
Agrawal, M., Atikuzzaman, M. D., Cinderby, S., Engardt, M., Jamir, C.,
Kobayashi, K., Oanh, N. T. K., Quadir, Q. F., and Wahid, A.: A comparison of
North American and Asian exposure–response data for ozone effects on crop
yields, Atmos. Environ., 43, 1945–1953, 2009.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>Entegris: Properties and characteristics of graphite, available at:
<ext-link xlink:href="https://www.entegris.com/content/dam/web/resources/manuals-and-guides/manual-properties-and-characteristics-of-graphite-109441.pdf">https://www.entegris.com/content/dam/web/resources/manuals-and-guides/manual-properties-and-characteristics-of-graphite-109441.pdf</ext-link>
(last access: 12 June 2017), 2015.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>
Fang, F., Wang, Q., and Li, J.: Urban environmental mercury in Changchun, a
metropolitan city in Northeastern China: Source, cycle, and fate, Sci. Total
Environ., 330, 159-170, 2004.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>
Finlayson-Pitts, B. J. and Pitts, J. N.: Chemistry of the Upper and Lower
Atmosphere: Theory, Experiments and Applications, Academic Press, San Diego,
USA, 2000.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>
Garetano, G., Gochfeld, M., and Stern, A. H.: Comparison of indoor mercury
vapor in common areas of residential buildings with outdoor levels in a
community where mercury is used for cultural purposes, Environ. Health
Perspect., 114, 59–62, 2006.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>
Greenberg, J. P., Lee, B., Helmig, D., and Zimmerman, P. R.: Fully automated
gas chromatograph-flame ionization detector system for the in situ
determination of atmospheric non-methane hydrocarbons at low parts per
trillion concentration, J. Chrom. A., 676, 389–398, 1994.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>
Griffin, R. J., Cocker, D. R., Flagan, R. C., and Seinfeld, J. H.: Organic
aerosol formation from the oxidation of biogenic hydrocarbons, J. Geophys.
Res., 104, 3555–3567, 1999.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>
Grosjean, D. and Harrison, J.: Response of chemiluminescent NOx analyzers and
ultraviolet ozone analyzers to organic air pollutants, Environ. Sci.
Technol., 19, 862–865, 1985.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>
Haagen-Smit, A. J. and Fox, M. M.: Photochemical ozone formation with
hydrocarbons and automobile exhaust, J. Air Pollut. Control Assoc., 4,
105–108, 1954.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>
Hennig, G. R.: Anisoptropic reactivities of graphite – I. Reactions of ozone
and graphite, Carbon, 3, 107–114, 1965.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>
Huntzicker, J. A. and Johnson, R. L.: Investigations of an ambient
interference in the measurement of ozone by ultraviolet photometry, Environ.
Sci. Technol., 13, 1414–1416, 1979.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>Keller-Rudek, H., Moortgat, G. K., Sander, R., and Sörensen, R.: The
MPI-Mainz UV/VIS Spectral Atlas of Gaseous Molecules of Atmospheric Interest,
Earth Syst. Sci. Data, 5, 365–373, <ext-link xlink:href="https://doi.org/10.5194/essd-5-365-2013" ext-link-type="DOI">10.5194/essd-5-365-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
Kim, K. H. and Kim, M. Y.: A decadal shift in total gaseous mercury
concentration levels in Seoul, Korea: changes between the late 1980s and the
late 1990s, Atmos. Environ., 36, 663–675, 2002.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>
Kleindienst, T. E., Hudgens, E. E., Smith, D. F., McElroy, F. F., and
Bufalini, J. J.: Comparison of chemiluminescence and ultraviolet ozone
monitor responses in the presence of humidity and photochemical pollutants,
J. Air Waste Manage., 43, 213–222, 1993.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>Lee, A., Goldstein, A. H., Keywood, M. D., Gao, S., Varutbangkul, V.,
Bahreini, R., Ng, N. L., Flagan, R. C., and Seinfeld, J. H.: Gas-phase
products and secondary aerosol yields from the ozonolysis of ten different
terpenes, J. Geophys. Res., 111, D07302, <ext-link xlink:href="https://doi.org/10.1029/2006JD007050" ext-link-type="DOI">10.1029/2006JD007050</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>
Lee, P. and Davidson, J.: Evaluation of activated carbon filters for removal
of ozone at the ppb level, J. Am. Ind. Hyg., 60, 589–600, 1999.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>Leston, A. R., Ollison, W. M., Spicer, C. W., and Satola, J.: Potential
interference bias in ozone standard compliance monitoring, J. Air Waste
Manage., 55, 1464–1472, <ext-link xlink:href="https://doi.org/10.1080/10473289.2005.10464749" ext-link-type="DOI">10.1080/10473289.2005.10464749</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>
Li, Y., Lee, S.-R., and Wu, C.-Y.: UV-absorption-based measurements of ozone
and mercury: an investigation on their mutual interferences, Aerosol Air
Quality Res., 6, 418–429, 2006.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>
Liu, S., Nadim, F., Perkins, C., Carley, R. J., Hoag, G. E., Lin, Y., and
Chen, L.: Atmospheric mercury monitoring survey in Beijing, China,
Chemosphere, 48, 97–107, 2002.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>
Mahmoud, F. M., Kang, D., and Aneja, V. P.: Volatile organic compounds in
some urban locations in the United States, Chemosphere, 47, 863–882, 2002.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><mixed-citation>McCarthy, J. E. and Lattanzio, R. K.: Ozone Air Quality Standards: EPA's 2015
Revision, Congressional Research Reports Publication #R43092, available
at: <uri>https://fas.org/sgp/crs/misc/R43092.pdf</uri> (last access: 12 June
2017), 2016.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation>
Meyer, C. P., Elsworth, C. M., and Galbally, I. E.: Water vapor interference
in the measurement of ozone in ambient air by ultraviolet absorption, Rev.
Sci. Instrum., 62, 223–228, 1991.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><mixed-citation>
Obrist, D., Hallar, A. G., McCubbin, I., Stephens, B. B., and Rahn, T.:
Atmospheric mercury concentrations at Storm Peak Laboratory in the Rocky
Mountains: Evidence for long-range transport from Asia, boundary layer
contributions, and plant mercury uptake, Atmos. Environ., 42, 7579–7589,
2008.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><mixed-citation>Ollison, W. M., Crow, W., and Spicer, C. W.: Field testing of new technology
ambient air ozone monitors, J. Air Waste Manage., 63, 855–863,
<ext-link xlink:href="https://doi.org/10.1080/10962247.2013.796898" ext-link-type="DOI">10.1080/10962247.2013.796898</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><mixed-citation>
Parrish, D. D. and Fehsenfeld, F. C.: Methods for gas-phase measurements of
ozone, ozone precursors and aerosol precursors, Atmos. Environ. 34,
1921–1957, 2000.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><mixed-citation>
Razumovskii, S. D., Gorshenev, V. N., Kovarskii, A. L., Kuznetsov, A. M., and
Shchegolikhin, A. N.: Carbon nanostructure reactivity: Reactions of graphite
powders with ozone, Fuller. Nanotub. Car. N., 15, 53–63, 2007.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><mixed-citation>
Ryerson, T. B., Buhr, M. P., Frost, G. J., Goldan, P. D., Holloway, J. S.,
Hubler, G., Jobson, B. T., Kuster, W. C., McKeen, S. A., Parrish, D. D.,
Roberts, J. M., Sueper, D. T., Trainer, M., Williams, J., and Fehsenfeld, F.
C.: Emissions lifetimes and ozone formation in power plant plumes, J.
Geophys. Res., 103, 22569–22583, 1998.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><mixed-citation>Saathoff, H., Kamm, S., Möhler, O., Naumann, K.-H., and Schurath, U.:
Kinetics and Mechanism of the Heterogeneous Interaction of Ozone with Soot
Aerosol, J. Aerosol Sci., 29, S889–S890, 1998.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib46"><label>46</label><mixed-citation>
Seila, R. L., Lonneman, W. A., and Meeks, S. A.: Determination of C2 to C12
ambient air hydrocarbons in 39 U.S. cities from 1984 through 1986, EPA report
/600/S3-89/058, Springfield, USA, 1989.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><mixed-citation>
Shields, H. C., Weschler, C. W., and Naik, D.: Ozone removal by charcoal
filters after continuous extensive use (5 to 8 years), Proceedings of the 8th
International Conference on Indoor Air Quality and Climate, Indoor Air 99,
8–13 August 1999, Edinburgh, UK, Vol. 4, 49–54, 1999.</mixed-citation></ref>
      <ref id="bib1.bib48"><label>48</label><mixed-citation>
Smith, D. M. and Chughtai, A. R.: Reaction Kinetics of Ozone at Low
Concentrations with n-Hexane Soot, J. Geophys. Res., 101, 19607–19620, 1996.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><mixed-citation>Spicer, C. W., Joseph, D. W., and Ollison, W. M.: A re-examination of ambient
air ozone monitor interferences, J. Air Waste Manage., 60, 1353–1364,
<ext-link xlink:href="https://doi.org/10.3155/1047-3289.60.11.1353" ext-link-type="DOI">10.3155/1047-3289.60.11.1353</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib50"><label>50</label><mixed-citation>
Stephens, S. L., Birks, J. W., and Calvert, J. G.: Ozone as a Sink for
Atmospheric Carbon Aerosols Today and Following Nuclear War, Aerosol Sci.
Technol., 10, 326–331, 1989.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><mixed-citation>
Tracz, A., Wegner, G., and Rabe, J. P.: Scanning tunneling microscopy study
of graphite oxidation in ozone-air mixtures, Langmuir, 19, 6807–6812, 2003.</mixed-citation></ref>
      <ref id="bib1.bib52"><label>52</label><mixed-citation>
U.S.-EPA: Laboratory Study to Explore Potential Interferences to Air Quality
Monitors, EPA-454/C-00-002, Office of Air Quality Planning and Standards:
Research Triangle Park, NC, USA, 1999.</mixed-citation></ref>
      <ref id="bib1.bib53"><label>53</label><mixed-citation>U.S.-EPA: Health Effects of Ozone in the General Population, available at:
<ext-link xlink:href="https://www.epa.gov/ozone-pollution-and-your-patients-health/health-effects-ozone-general-population">https://www.epa.gov/ozone-pollution-and-your-patients-health/health-effects-ozone-general-population</ext-link>,
last access: October 2016.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><mixed-citation>
Weisel, C. P., Cody, R. P., and Lioy, P. J .: Relationship between summertime
ambient ozone levels and emergency department visits for asthma in central
New Jersey (suppl. 2), Environ. Health Perspect., 103, 97–102, 1995.</mixed-citation></ref>
      <ref id="bib1.bib55"><label>55</label><mixed-citation>
Weiss-Penzias, P., Jaffe, D. A., McClintick, A., Prestbo, E., and Landis, M.
S.: Gaseous elemental mercury in the marine boundary layer: Evidence for
rapid removal in anthropogenic pollution, Environ. Sci. Technol., 37,
3755–3763, 2003.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><mixed-citation>
White, M. C., Etzel, R. A., Wilcox, W. D., and Lloyd, C.: Exacerbations of
childhood asthma and ozone pollution in Atlanta, Environ. Res., 65, 56–68,
1994.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><mixed-citation>
Wilson, K. L. and Birks, J. W.: Mechanism and elimination of a water vapor
interference in the measurement of ozone by UV absorbance, Environ. Sci.
Technol., 40, 6361–6367, 2006.</mixed-citation></ref>
      <ref id="bib1.bib58"><label>58</label><mixed-citation>
Zdanevitch, I.: Study of Ozone Measurement Interferences: Final Report,
DRC-02-39246-AIRE-673-v2-Izd; Institut National de L'Environnement Industriel
et des Risques (INERIS), Verneuil-en-Halatte, France, 2002.</mixed-citation></ref>

  </ref-list><app-group content-type="float"><app><title/>

    </app></app-group></back>
    <!--<article-title-html>Use of a heated graphite scrubber as a means of reducing interferences in UV-absorbance measurements of atmospheric ozone</article-title-html>
<abstract-html><p class="p">A new solid-phase scrubber for use in conventional ozone (O<sub>3</sub>)
photometers was investigated as a means of reducing interferences from other
UV-absorbing species and water vapor. It was found that when heated to
100–130 °C, a tubular graphite scrubber efficiently removed up to
500 ppb ozone and ozone monitors using the heated graphite scrubber were
found to be less susceptible to interferences from water vapor, mercury
vapor, and aromatic volatile organic compounds (VOCs) compared to
conventional metal oxide scrubbers. Ambient measurements from a graphite
scrubber-equipped photometer and a co-located Federal equivalent
method (FEM)
ozone analyzer showed excellent agreement over 38 days of measurements and
indicated no loss in the scrubber's ability to remove ozone when operated at
130 °C. The use of a heated graphite scrubber was found to reduce
the interference from mercury vapor to  ≤  3 % of that obtained using
a packed-bed Hopcalite scrubber. For a series of substituted aromatic
compounds (ranging in volatility and absorption cross section at 253.7 nm),
the graphite scrubber was observed to consistently exhibit reduced levels of
interference, typically by factors of 2.5 to 20 less than with Hopcalite.
Conventional solid-phase scrubbers also exhibited complex VOC adsorption and
desorption characteristics that were dependent upon the relative humidity
(RH), volatility of the VOC, and the available surface area of the scrubber.
This complex behavior involving humidity is avoided by use of a heated
graphite scrubber. These results suggest that heated graphite scrubbers could
be substituted in most ozone photometers as a means of reducing interferences
from other UV-absorbing species found in the atmosphere. This could be
particularly important in ozone monitoring for compliance with the United
States (U.S.) Clean Air Act or for use in VOC-rich environments such as in
smog chambers and monitoring indoor air quality.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Avnery, S., Mauzerall, D. L., Liu, J., and Horowitz, L. W.: Global crop yield
reductions due to surface ozone exposure: 1. Year 2000 crop production losses
and economic damage, Atmos. Environ., 45, 2284–2296, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Bernardo-Bricker, A., Farmer, C. Milne, P., Riemer, D., Zika, R., and
Stoneking, C.: Validation of speciated nonmethane hydrocarbon compound data
collected during the 1992 Atlanta Intensive as part of the Southern Oxidants
Study, J. Air Waste Manage., 45, 591–603, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Birks, J. W., Williford, C. J., and Andersen, P. C.: Use of a Broad Band UV
Light Source for Reducing the Mercury Interference in Ozone Measurements,
U.S. Patent Application US 2009/0302230 A1, US Patent and Trademark Office,
Washington, D.C., USA, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Birks, J. W., Andersen, P. C., and Williford, C. J.: Ozone monitor with
gas-phase scrubber, U.S. Patent US 8,395,776 B2, US Patent and Trademark
Office, Washington, D.C., USA, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Birks, J. W., Turnipseed, A. A., Andersen, P. C., and Williford, C. J.:
Heated Graphite Scrubber to Reduce Interferences in Ozone Monitors, U.S.
Patent US 2016/0025696 A1, US Patent and Trademark Office, Washington, D.C.,
USA, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Burkholder, J. B., Sander, S. P., Abbatt, J., Barker, J. R., Huie, R. E.,
Kolb, C. E., Kurylo, M. J., Orkin, V. L., Wilmouth, D. M., and Wine, P. H.:
Chemical Kinetics and Photochemical Data for Use in Atmospheric Studies,
Evaluation No. 18, JPL Publication 15-10, Jet Propulsion Laboratory,
Pasadena, USA, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Burnett, R. T., Brook, J. R., Yung, W. T., Dales, R. E., and Krewski, D.:
Association between ozone and hospitalization for respiratory diseases in
16 Canadian cities, Environ. Res., 72, 24–31, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Carpi, A. and Chen, Y. F.: Gaseous elemental mercury as an indoor air
pollutant, Environ. Sci. Technol., 35, 4170–4173, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Chameides, W. L. and Walker, J. C. G.: A photochemical theory of tropospheric
ozone, J. Geophys. Res., 78, 8751–8759, 1973.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Davies, L.: Nitrobenzene, International Programme on Chemical Safety –
Environmental Health Criteria 230, World Health Organization, Geneva,
Switzerland, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Delhomme, O., Morville, S., and Millet, M.: Seasonal and diurnal variations
of atmospheric concentrations of phenols and nitrophenols measured in the
Strasborg area, France, Atmos. Pollut. Res., 1, 16–22, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Denis, M. St., Song, X., Lu, J. Y., and Feng, X.: Atmospheric gaseous
elemental mercury in downtown Toronto, Atmos. Environ, 40, 4016–4024, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Dumarey, R., Dams, R., and Hoste, J.: Comparison of the collection and
desorption efficiency of activated charcoal, silver and gold for the
determination of vapor-phase atmospheric mercury, Anal. Chem., 57,
2638–2644, 1985.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Dunlea, E. J., Herndon, S. C., Nelson, D. D., Volkamer, R. M., Lamb, B. K.,
Allwine, E. J., Grutter, M., Ramos Villegas, C. R., Marquez, C., Blanco, S.,
Cardenas, B., Kolb, C. E., Molina, L. T., and Molina, M. J.: Technical note:
Evaluation of standard ultraviolet absorption ozone monitors in a polluted
urban environment, Atmos. Chem. Phys., 6, 3163–3180,
<a href="https://doi.org/10.5194/acp-6-3163-2006" target="_blank">doi:10.5194/acp-6-3163-2006</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Eiguren-Fernandez, A., Miguel, A. H., Foines, J. R., Thurairatnam, S., and
Avol, E. L.: Seasonal and spatial variation of polycyclic aromatic
hydrocarbons in vapor-phase and PM<sub>2. 5</sub> in Southern California urban and
rural communities, Aerosol Sci. Tech., 38, 447–455, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Ellis, W. D. and Tometz, P. V.: Room-temperature catalytic decomposition of
ozone, Atmos. Environ., 6, 707–714, 1972.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Emberson, L., Ashmore, M., and Murray, F.: Air Pollution Impacts on Crops and
Forests. A Global Assessment, Imperial College Press, London, UK, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Emberson, L. D., Büker, P., Ashmore, M. R., Mills, G., Jackson, L. S.,
Agrawal, M., Atikuzzaman, M. D., Cinderby, S., Engardt, M., Jamir, C.,
Kobayashi, K., Oanh, N. T. K., Quadir, Q. F., and Wahid, A.: A comparison of
North American and Asian exposure–response data for ozone effects on crop
yields, Atmos. Environ., 43, 1945–1953, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Entegris: Properties and characteristics of graphite, available at:
<a href="https://www.entegris.com/content/dam/web/resources/manuals-and-guides/manual-properties-and-characteristics-of-graphite-109441.pdf" target="_blank">https://www.entegris.com/content/dam/web/resources/manuals-and-guides/manual-properties-and-characteristics-of-graphite-109441.pdf</a>
(last access: 12 June 2017), 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Fang, F., Wang, Q., and Li, J.: Urban environmental mercury in Changchun, a
metropolitan city in Northeastern China: Source, cycle, and fate, Sci. Total
Environ., 330, 159-170, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Finlayson-Pitts, B. J. and Pitts, J. N.: Chemistry of the Upper and Lower
Atmosphere: Theory, Experiments and Applications, Academic Press, San Diego,
USA, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Garetano, G., Gochfeld, M., and Stern, A. H.: Comparison of indoor mercury
vapor in common areas of residential buildings with outdoor levels in a
community where mercury is used for cultural purposes, Environ. Health
Perspect., 114, 59–62, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Greenberg, J. P., Lee, B., Helmig, D., and Zimmerman, P. R.: Fully automated
gas chromatograph-flame ionization detector system for the in situ
determination of atmospheric non-methane hydrocarbons at low parts per
trillion concentration, J. Chrom. A., 676, 389–398, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Griffin, R. J., Cocker, D. R., Flagan, R. C., and Seinfeld, J. H.: Organic
aerosol formation from the oxidation of biogenic hydrocarbons, J. Geophys.
Res., 104, 3555–3567, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Grosjean, D. and Harrison, J.: Response of chemiluminescent NOx analyzers and
ultraviolet ozone analyzers to organic air pollutants, Environ. Sci.
Technol., 19, 862–865, 1985.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Haagen-Smit, A. J. and Fox, M. M.: Photochemical ozone formation with
hydrocarbons and automobile exhaust, J. Air Pollut. Control Assoc., 4,
105–108, 1954.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Hennig, G. R.: Anisoptropic reactivities of graphite – I. Reactions of ozone
and graphite, Carbon, 3, 107–114, 1965.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Huntzicker, J. A. and Johnson, R. L.: Investigations of an ambient
interference in the measurement of ozone by ultraviolet photometry, Environ.
Sci. Technol., 13, 1414–1416, 1979.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Keller-Rudek, H., Moortgat, G. K., Sander, R., and Sörensen, R.: The
MPI-Mainz UV/VIS Spectral Atlas of Gaseous Molecules of Atmospheric Interest,
Earth Syst. Sci. Data, 5, 365–373, <a href="https://doi.org/10.5194/essd-5-365-2013" target="_blank">doi:10.5194/essd-5-365-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Kim, K. H. and Kim, M. Y.: A decadal shift in total gaseous mercury
concentration levels in Seoul, Korea: changes between the late 1980s and the
late 1990s, Atmos. Environ., 36, 663–675, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Kleindienst, T. E., Hudgens, E. E., Smith, D. F., McElroy, F. F., and
Bufalini, J. J.: Comparison of chemiluminescence and ultraviolet ozone
monitor responses in the presence of humidity and photochemical pollutants,
J. Air Waste Manage., 43, 213–222, 1993.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Lee, A., Goldstein, A. H., Keywood, M. D., Gao, S., Varutbangkul, V.,
Bahreini, R., Ng, N. L., Flagan, R. C., and Seinfeld, J. H.: Gas-phase
products and secondary aerosol yields from the ozonolysis of ten different
terpenes, J. Geophys. Res., 111, D07302, <a href="https://doi.org/10.1029/2006JD007050" target="_blank">doi:10.1029/2006JD007050</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Lee, P. and Davidson, J.: Evaluation of activated carbon filters for removal
of ozone at the ppb level, J. Am. Ind. Hyg., 60, 589–600, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Leston, A. R., Ollison, W. M., Spicer, C. W., and Satola, J.: Potential
interference bias in ozone standard compliance monitoring, J. Air Waste
Manage., 55, 1464–1472, <a href="https://doi.org/10.1080/10473289.2005.10464749" target="_blank">doi:10.1080/10473289.2005.10464749</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Li, Y., Lee, S.-R., and Wu, C.-Y.: UV-absorption-based measurements of ozone
and mercury: an investigation on their mutual interferences, Aerosol Air
Quality Res., 6, 418–429, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Liu, S., Nadim, F., Perkins, C., Carley, R. J., Hoag, G. E., Lin, Y., and
Chen, L.: Atmospheric mercury monitoring survey in Beijing, China,
Chemosphere, 48, 97–107, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Mahmoud, F. M., Kang, D., and Aneja, V. P.: Volatile organic compounds in
some urban locations in the United States, Chemosphere, 47, 863–882, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
McCarthy, J. E. and Lattanzio, R. K.: Ozone Air Quality Standards: EPA's 2015
Revision, Congressional Research Reports Publication #R43092, available
at: <a href="https://fas.org/sgp/crs/misc/R43092.pdf" target="_blank">https://fas.org/sgp/crs/misc/R43092.pdf</a> (last access: 12 June
2017), 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
Meyer, C. P., Elsworth, C. M., and Galbally, I. E.: Water vapor interference
in the measurement of ozone in ambient air by ultraviolet absorption, Rev.
Sci. Instrum., 62, 223–228, 1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Obrist, D., Hallar, A. G., McCubbin, I., Stephens, B. B., and Rahn, T.:
Atmospheric mercury concentrations at Storm Peak Laboratory in the Rocky
Mountains: Evidence for long-range transport from Asia, boundary layer
contributions, and plant mercury uptake, Atmos. Environ., 42, 7579–7589,
2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Ollison, W. M., Crow, W., and Spicer, C. W.: Field testing of new technology
ambient air ozone monitors, J. Air Waste Manage., 63, 855–863,
<a href="https://doi.org/10.1080/10962247.2013.796898" target="_blank">doi:10.1080/10962247.2013.796898</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Parrish, D. D. and Fehsenfeld, F. C.: Methods for gas-phase measurements of
ozone, ozone precursors and aerosol precursors, Atmos. Environ. 34,
1921–1957, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
Razumovskii, S. D., Gorshenev, V. N., Kovarskii, A. L., Kuznetsov, A. M., and
Shchegolikhin, A. N.: Carbon nanostructure reactivity: Reactions of graphite
powders with ozone, Fuller. Nanotub. Car. N., 15, 53–63, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Ryerson, T. B., Buhr, M. P., Frost, G. J., Goldan, P. D., Holloway, J. S.,
Hubler, G., Jobson, B. T., Kuster, W. C., McKeen, S. A., Parrish, D. D.,
Roberts, J. M., Sueper, D. T., Trainer, M., Williams, J., and Fehsenfeld, F.
C.: Emissions lifetimes and ozone formation in power plant plumes, J.
Geophys. Res., 103, 22569–22583, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Saathoff, H., Kamm, S., Möhler, O., Naumann, K.-H., and Schurath, U.:
Kinetics and Mechanism of the Heterogeneous Interaction of Ozone with Soot
Aerosol, J. Aerosol Sci., 29, S889–S890, 1998.

</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
Seila, R. L., Lonneman, W. A., and Meeks, S. A.: Determination of C2 to C12
ambient air hydrocarbons in 39 U.S. cities from 1984 through 1986, EPA report
/600/S3-89/058, Springfield, USA, 1989.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Shields, H. C., Weschler, C. W., and Naik, D.: Ozone removal by charcoal
filters after continuous extensive use (5 to 8 years), Proceedings of the 8th
International Conference on Indoor Air Quality and Climate, Indoor Air 99,
8–13 August 1999, Edinburgh, UK, Vol. 4, 49–54, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation>
Smith, D. M. and Chughtai, A. R.: Reaction Kinetics of Ozone at Low
Concentrations with n-Hexane Soot, J. Geophys. Res., 101, 19607–19620, 1996.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation>
Spicer, C. W., Joseph, D. W., and Ollison, W. M.: A re-examination of ambient
air ozone monitor interferences, J. Air Waste Manage., 60, 1353–1364,
<a href="https://doi.org/10.3155/1047-3289.60.11.1353" target="_blank">doi:10.3155/1047-3289.60.11.1353</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation>
Stephens, S. L., Birks, J. W., and Calvert, J. G.: Ozone as a Sink for
Atmospheric Carbon Aerosols Today and Following Nuclear War, Aerosol Sci.
Technol., 10, 326–331, 1989.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation>
Tracz, A., Wegner, G., and Rabe, J. P.: Scanning tunneling microscopy study
of graphite oxidation in ozone-air mixtures, Langmuir, 19, 6807–6812, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation>
U.S.-EPA: Laboratory Study to Explore Potential Interferences to Air Quality
Monitors, EPA-454/C-00-002, Office of Air Quality Planning and Standards:
Research Triangle Park, NC, USA, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation>
U.S.-EPA: Health Effects of Ozone in the General Population, available at:
<a href="https://www.epa.gov/ozone-pollution-and-your-patients-health/health-effects-ozone-general-population" target="_blank">https://www.epa.gov/ozone-pollution-and-your-patients-health/health-effects-ozone-general-population</a>,
last access: October 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation>
Weisel, C. P., Cody, R. P., and Lioy, P. J .: Relationship between summertime
ambient ozone levels and emergency department visits for asthma in central
New Jersey (suppl. 2), Environ. Health Perspect., 103, 97–102, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation>
Weiss-Penzias, P., Jaffe, D. A., McClintick, A., Prestbo, E., and Landis, M.
S.: Gaseous elemental mercury in the marine boundary layer: Evidence for
rapid removal in anthropogenic pollution, Environ. Sci. Technol., 37,
3755–3763, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation>
White, M. C., Etzel, R. A., Wilcox, W. D., and Lloyd, C.: Exacerbations of
childhood asthma and ozone pollution in Atlanta, Environ. Res., 65, 56–68,
1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation>
Wilson, K. L. and Birks, J. W.: Mechanism and elimination of a water vapor
interference in the measurement of ozone by UV absorbance, Environ. Sci.
Technol., 40, 6361–6367, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>58</label><mixed-citation>
Zdanevitch, I.: Study of Ozone Measurement Interferences: Final Report,
DRC-02-39246-AIRE-673-v2-Izd; Institut National de L'Environnement Industriel
et des Risques (INERIS), Verneuil-en-Halatte, France, 2002.
</mixed-citation></ref-html>--></article>
