<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0"><?xmltex \makeatother\@nolinetrue\makeatletter?>
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-11-141-2018</article-id><title-group><article-title>Comparison of VOC measurements made by PTR-MS,
adsorbent tubes–GC-FID-MS and DNPH derivatization–HPLC
during the Sydney Particle Study, 2012: a contribution to
the assessment of uncertainty in routine atmospheric VOC measurements</article-title><alt-title>An assessment of uncertainty in  atmospheric VOC measurements</alt-title>
      </title-group><?xmltex \runningtitle{An assessment of uncertainty in  atmospheric VOC measurements}?><?xmltex \runningauthor{E.~Dunne et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name><surname>Dunne</surname><given-names>Erin</given-names></name>
          <email>erin.dunne@csiro.au</email>
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Galbally</surname><given-names>Ian E.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2383-1360</ext-link></contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Cheng</surname><given-names>Min</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Selleck</surname><given-names>Paul</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Molloy</surname><given-names>Suzie B.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Lawson</surname><given-names>Sarah J.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2009-0149</ext-link></contrib>
        <aff id="aff1"><institution>CSIRO Oceans and Atmosphere, Aspendale, 3195, Australia</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Erin Dunne (erin.dunne@csiro.au)</corresp></author-notes><pub-date><day>10</day><month>January</month><year>2018</year></pub-date>
      
      <volume>11</volume>
      <issue>1</issue>
      <fpage>141</fpage><lpage>159</lpage>
      <history>
        <date date-type="received"><day>17</day><month>October</month><year>2016</year></date>
           <date date-type="accepted"><day>14</day><month>November</month><year>2017</year></date>
           <date date-type="rev-recd"><day>3</day><month>November</month><year>2017</year></date>
           <date date-type="rev-request"><day>27</day><month>January</month><year>2017</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2018 Erin Dunne et al.</copyright-statement>
        <copyright-year>2018</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 3.0 Unported License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/3.0/">https://creativecommons.org/licenses/by/3.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/11/141/2018/amt-11-141-2018.html">This article is available from https://amt.copernicus.org/articles/11/141/2018/amt-11-141-2018.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/11/141/2018/amt-11-141-2018.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/11/141/2018/amt-11-141-2018.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e123">Understanding uncertainty is essential for utilizing atmospheric volatile organic compound
(VOC) measurements in robust ways to develop atmospheric science. This study
describes an inter-comparison of the VOC data, and the derived uncertainty
estimates, measured with three independent techniques (PTR-MS,
proton-transfer-reaction mass spectrometry; GC-FID-MS,
gas chromatography with flame-ionization and mass spectrometric detection;
and DNPH–HPLC, 2,4-dinitrophenylhydrazine derivatization followed by analysis by high-performance
liquid chromatography)
during routine monitoring as part of the Sydney Particle Study (SPS) campaign in 2012. Benzene, toluene, <inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics, isoprene,
formaldehyde and acetaldehyde were selected for the comparison, based on
objective selection criteria from the available data. Bottom-up uncertainty
analyses were undertaken for each compound and each measurement system.
Top-down uncertainties were quantified via the inter-comparisons. In all
seven comparisons, the correlations between independent measurement
techniques were high with <inline-formula><mml:math id="M2" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> values with a median of 0.92 (range 0.75–0.98)
and small root mean square of the deviations (RMSD) of the observations from the regression
line with a median of 0.11 (range 0.04–0.23 <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>). These results
give a high degree of confidence that for each comparison the response of the
two independent techniques is dominated by the same constituents. The slope
and intercept as determined by reduced major axis (RMA) regression gives
a different story. The slopes varied considerably with a median of 1.25 and
a range of 1.16–2.01. The intercepts varied with a median of 0.04 and a range
of <inline-formula><mml:math id="M4" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.03 to 0.31 <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>. An ideal comparison would give a slope of 1.00
and an intercept of 0.</p>
    <p id="d1e171">Some sources of uncertainty that are poorly quantified by the bottom-up uncertainty analysis method were identified, including:
contributions of non-target compounds to the measurement of the target compound for benzene, toluene and isoprene by PTR-MS as well as the
under-reporting of formaldehyde, acetaldehyde and acetone by the DNPH technique. As well as these, this study has identified a specific
interference of liquid water with acetone measurements by the DNPH technique.</p>
    <p id="d1e174">These relationships reported for Sydney 2012 were incorporated into a larger analysis with 61 similar published inter-comparison
studies for the same compounds. Overall, for the light aromatics, isoprene and the <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math id="M7" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> carbonyls, the uncertainty
in a set of measurements varies by a factor of between 1.5 and 2. These uncertainties (<inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">50</mml:mn></mml:mrow></mml:math></inline-formula> %) are significantly higher
than uncertainties estimated using standard propagation of error methods, which in this case were <inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:math></inline-formula> % or less, and are
the result of the presence of poorly understood or neglected processes that affect the measurement and its uncertainty. The
uncertainties in VOC measurements identified here should be considered when assessing the reliability of VOC measurements from routine
monitoring with individual, stand-alone instruments; when utilizing VOC data to constrain and inform air quality and climate models;
when using VOC observations for human exposure studies; and for comparison with satellite retrievals.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<?pagebreak page142?><sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e228">Volatile organic compounds (VOCs) in the atmosphere have important roles in processes leading to formation of ozone and secondary
organic aerosol,
and quantitative measurements of VOCs are important for source reconciliation, verification of atmospheric
models and exposure assessment.  While atmospheric VOC measurements commenced around 60 years ago, measurement techniques are
still rapidly evolving and the uncertainties associated with these measurements are often poorly understood. Assessment of uncertainty
for VOC measurement techniques by standard methods (Harris, 2003; JCGM, 2008) often underestimates what happens in practice because of
the presence of poorly understood or neglected processes that affect the measurement and its uncertainty. However comparison of
independent techniques for measuring individual VOCs provides a more critical test of uncertainties. Inter-comparison of independent
techniques and their quantification of measurement uncertainty can collectively contribute significantly to the tasks of validation of
a wider range of new knowledge, particularly where atmospheric VOC observations are used to validate VOC emissions inventories, air
chemistry models and human exposure to air toxins.</p>
      <p id="d1e231">Uncertainty in measurements of atmospheric constituents, including VOCs, can arise from four components of the measurement process:
<list list-type="bullet"><list-item>
      <p id="d1e236">the pretreatment of the sample (e.g. in the inlet or adsorption, storage and desorption on
a cartridge),</p></list-item><list-item>
      <p id="d1e240">the matrix in which the sample (and calibration standards) are presented to
the detector (e.g. in nitrogen, helium, air or some complex mixture),</p></list-item><list-item>
      <p id="d1e244">the presence of interfering compounds in the sample (e.g. co-eluting in
chromatography or isobaric compounds in mass spectrometry) and</p></list-item><list-item>
      <p id="d1e248">the instrument calibration (e.g. calibration standards used, linearity of
detector response).</p></list-item></list>
There are three distinct methods of determining these uncertainties in VOC measurements. In the first approach, one can examine the
individual components of a single measurement technique and assess the uncertainty of each and combine these to get a total uncertainty
for that method as described in the Guide to Expression of Uncertainty in Measurement (JCGM, 2008). With this approach, one question always remains:
were any sources of uncertainty overlooked? The second method is to make multiple paired measurements with different measurement
techniques, of either synthetic VOC mixtures in cylinders or from air in chambers, and determine the uncertainty from the resulting
paired and replicate measurements. This again only captures a partial contribution to the uncertainty, but it is particularly effective
in identifying the presence of unknown sources of uncertainty and complements the first approach. The third approach, used here, is to
undertake multiple paired measurements of ambient air. This approach does not allow replicate analyses but has the advantage of
including the influence of environmental and operational factors on the measurement uncertainty.</p>
      <p id="d1e252">Three independent VOC measurement systems were employed in the study presented here: continuous measurements by
proton-transfer-reaction mass spectrometry (PTR-MS), integrated 5–10 <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula> samples on VOC adsorbent tubes with subsequent offline analysis by
GC-FID-MS (gas chromatography with flame-ionization and mass spectrometric
detection) based on the United States
Environmental Protection Agency (USEPA) Method TO 17 (USEPA, 1999a) and integrated 5–10 <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula> samples on 2,4-dinitrophenylhydrazine (DNPH)
cartridges with subsequent offline analysis by high-performance
liquid chromatography (HPLC) based on USEPA Method TO 11A (USEPA, 1999b). While notable examples
exist, e.g. Kajos et al. (2015), there is no widely accepted procedure for assessing uncertainty in PTR-MS measurements. Furthermore, while TO
17 and TO 11A provide quality control criteria they do not provide a procedure for systematic uncertainty analysis.</p>
      <p id="d1e271">The Sydney Particle Study (SPS) was an intensive field experiment designed to provide a detailed characterization of the chemical and
aerosol composition of the urban atmosphere in Sydney, Australia, in summer 2011 and autumn 2012 (Cope et al., 2014). Sydney is
Australia's largest city (population <inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">4.3</mml:mn></mml:mrow></mml:math></inline-formula> million) and occasionally (<inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">days</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">yr</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) experiences exceedances of
minimum air quality standards for ozone and particulate matter (<inline-formula><mml:math id="M15" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) (OEH, 2015). In Sydney, the VOCs present were
dominated by those from biogenic sources, motor vehicles, bushfires and domestic wood heating (CSIRO 2008, Cope et al., 2014).</p>
      <p id="d1e323">The second SPS campaign, SPS 2, occurred in autumn from 15 April to 13 May 2012. The measurement site was approximately 1000 <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>
from the parent laboratory, where the equipment was transported and assembled before the study; therefore,
we suggest that the results are typical of normal operating conditions for these instruments rather than that of a specially selected intensive inter-comparison
study.</p>
      <p id="d1e334">The compounds selected for discussion in the proceeding analysis are a subset of the species measured by the PTR-MS, AT-VOC (adsorbent tube VOC sampling)
and DNPH techniques in SPS 2. For the full results of the PTR-MS, AT-VOC and DNPH analysis from SPS 2, the reader is referred to Keywood
et al. (2016).</p>
      <p id="d1e337">We present quantitative comparisons of concentrations of VOCs including (a) <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math id="M18" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatic compounds and isoprene
by PTR-MS and integrated VOC adsorbent tube measurements with subsequent GC-FID-MS analyses and (b) formaldehyde, acetaldehyde and
acetone by PTR-MS measurements and carbonyl compounds sampling onto DNPH cartridges followed by HPLC analysis. The results are
discussed with regard to the primary responses,<?pagebreak page143?> interfering species, standard uncertainty analyses and the limitations of the methods.</p>
      <p id="d1e362">The results from this study are compared with other inter-comparison data from the scientific literature and some conclusions about the
uncertainty in current VOC measurements presented.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Measurement site and set-up</title>
      <p id="d1e380">The sampling site (33.802<inline-formula><mml:math id="M19" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> S, 150.998<inline-formula><mml:math id="M20" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> E) was located in the Sydney suburb of Westmead, in the grounds of
a psychiatric hospital at a position greater than 500 <inline-formula><mml:math id="M21" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> from major roads. Measurements were conducted over the period 15 April–13 May 2012.
The PTR-MS and the sampling apparatus for both the VOC adsorbent tubes and the DNPH cartridges were located in
a demountable building surrounded by a grass-covered area with occasional trees and the nearest buildings were <inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> away.
The main VOC sampling inlet was <inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> above the roofline, consisting of an <inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">80</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M27" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> O.D. glass inlet of <inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> length.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Carbonyl-DNPH derivatization analysed by HPLC</title>
      <p id="d1e490">Ambient air was drawn from the main VOC sample inlet via <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> length of <inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula>-inch Silcosteel
tubing into a custom-designed automated sampler. The automated sampler is a continuous air sampler with two channels allowing for simultaneous extractive
sampling onto VOC adsorbent tubes and DNPH cartridges. The automated sampler has two inline flow sensors installed after the VOC and
DNPH sample manifolds. The 1 <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula> flows measured by the sensors are logged via the automated sampler software, and the total
sample volume for each VOC and DNPH sample was determined from the logged flows. The automated sampler was leak checked and the flow
sensor calibrated before and after the sample period by measuring the inlet and outlet flows for each sample port, ensuring they agreed
within 10 %. The exhaust flow was measured daily during sampling.</p>
      <p id="d1e531">Three samples per day (05:00–10:00, 11:00–19:00 and 19:00–05:00; all times are in local time)
were collected by the automated sampler which actively drew air
through DNPH coated solid silica adsorbent cartridges (Supelco LpDNPH S10, Supelco, Pennsylvania, USA), using a constant flow air
sampling pump at a set flow rate of 1 <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. One field blank and one lab blank per 10 samples were collected during the
sample period. In order to capture potential contamination during transport, storage and handling field blank tubes were uncapped and
installed in the automated sampler for the same period as the samples.</p>
      <p id="d1e551">There is a known deterioration, over 1 or more days, of derivatized DNPH-carbonyl samples at room temperature. Because of this, the
compartment housing the DNPH cartridges in the automated sampler was maintained at <inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M36" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and the cartridges were
refrigerated before and after sampling. An ozone scrubber (KI impregnated filter) was placed in front of the DNPH cartridges.</p>
      <p id="d1e573">The method of DNPH–HPLC sampling employed in this study is compatible with USEPA Method TO-11A (USEPA, 1999b). Following sampling, the
derivatives were eluted from the cartridge in 2.5 <inline-formula><mml:math id="M37" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi></mml:mrow></mml:math></inline-formula> of acetonitrile (HPLC grade, Merck) and analysed by high-performance
liquid chromatography consisting of a Dionex GP40 gradient pump, a Waters 717 autosampler, a Shimadzu system controller SCL-10A
VP, a Shimadzu diode array detector (DAD) SPD-M10A VP, a Shimadzu column oven CTO-10AS VP and Shimadzu CLASS-VP chromatography
software. Compound separation was performed with two Supelco Supelcosil LC-18 columns in series (5 <inline-formula><mml:math id="M38" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, 4.6 <inline-formula><mml:math id="M39" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> I.D.,
250 <inline-formula><mml:math id="M40" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> length, part no.  58298). The chromatographic conditions include a flow rate of 1.6 <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> and an
injection volume of 25 <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:mrow></mml:math></inline-formula>, and the DAD was operated in the 220–520 <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> wavelength range with 360 <inline-formula><mml:math id="M44" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> used
for mono-carbonyl quantification. The peaks were separated by gradient elution with an initial mobile phase of 64 % acetonitrile
and 36 % deionized water (18.2 <inline-formula><mml:math id="M45" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">M</mml:mi><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M46" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula>cm, Millipore Milli-Q Advantage) for 10 <inline-formula><mml:math id="M47" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula>, followed by a linear
gradient to 100 % acetonitrile for 20 <inline-formula><mml:math id="M48" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula>, and with a column temperature of 30 <inline-formula><mml:math id="M49" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. A certified liquid standard
(Supelco CARB Method 1004 DNPH Mix 2 C/N 47651-U) containing 30 <inline-formula><mml:math id="M50" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">g</mml:mi></mml:mrow></mml:math></inline-formula> m<inline-formula><mml:math id="M51" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">L</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> of each derivatized carbonyl was diluted
<inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">25</mml:mn></mml:mrow></mml:math></inline-formula> in a volumetric flask. This prepared standard was then used to perform a four-point calibration (0.15, 0.30, 0.6 and
1.2 <inline-formula><mml:math id="M53" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">g</mml:mi></mml:mrow></mml:math></inline-formula> m<inline-formula><mml:math id="M54" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">L</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). Further details of the DNPH method can be found in Lawson et al. (2008).</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>VOC adsorbent tubes analysed by GC-FID-MS (AT-VOC)</title>
      <p id="d1e765">In SPS 2, three samples per day (05:00–10:00, 11:00–19:00 and 19:00–05:00) were collected by the automated sampler which actively
drew air through two multi-adsorbent tubes in series (Markes Carbograph plus Carbopack X)
using a constant flow air sampling pump at a set flow
rate of 20 <inline-formula><mml:math id="M55" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>.  Tubes were conditioned and pre-analysed prior to use. Two tubes in series were installed for
every sample to check breakthrough for each analyte, which was <inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> % for all samples. One field blank and one lab blank per
10 samples were collected during the sample period. In order to capture potential contamination during transport, storage and handling
field blank tubes were uncapped and installed in the automated sampler for the same period as the samples. No flow was passed through
the blank tubes during the deployment period. Prior to and following sampling, tubes were capped and stored in an airtight metal tins
at <inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M58" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C.</p>
      <p id="d1e814">The adsorbent tubes were analysed by a PerkinElmer TurboMatrix<inline-formula><mml:math id="M59" display="inline"><mml:msup><mml:mi/><mml:mtext>TM</mml:mtext></mml:msup></mml:math></inline-formula> 650 ATD (automated thermal desorber) and a Hewlett Packard
6890A gas chromatograph (GC) equipped with flame-ionization detection (FID) and a mass spectrometer (MS).</p>
      <?pagebreak page144?><p id="d1e826">The method of adsorbent tube VOC sampling and analysis employed in this study was compatible with ISO16017-1:2000 and in
accordance with USEPA Compendium Method TO-17 (USEPA, 1999a).</p>
      <p id="d1e829">A series of certified gas standards including a BTEX standard (benzene, toluene, ethylbenzene and xylenes) (manufacturer stated
accuracy <inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> %) (Air Liquide–Scott Specialty Gases,
Longmont, CO, USA), a BTEX plus isoprene standard (National Physical Laboratory, Middlesex, UK)
(manufacturer stated accuracy <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> %), a TO-15 standard (Air Liquide, Plumsteadville, PA, USA) (manufacturer stated accuracy
<inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> %) and a photochemical assessment monitoring
stations (PAMS)
gas standard (Spectra Gases, Linde, NJ, USA) (manufacturer stated accuracy <inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> %) were used to
calibrate the GC-FID-MS. The calibration was done via an injection of the calibration gas onto an adsorption tube using a fixed volume
temperature-stabilized loop for standards with <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M65" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> individual VOCs and via sampling a known volume of calibration gas
onto an adsorption tube using a calibrated mass flow controller for standards with <inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> individual VOCs. Multiple
desorption tests on tubes loaded with a 10 <inline-formula><mml:math id="M68" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> BTEX calibration standard observed response factors on second desorption that
were 2 % or less than the response factors from the initial desorption, providing confidence that the analytes in the ambient
samples taken during SPS 2 were fully desorbed during the analysis process.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><title>Proton-transfer-reaction mass spectrometry (PTR-MS)</title>
      <p id="d1e925">A flow of 1.5 <inline-formula><mml:math id="M69" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> of ambient air was drawn off the main VOC inlet line via a second <inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> length of
<inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula>-inch O.D. Silcosteel tubing by a constant flow sampling pump through the PTR-MS auxiliary system and the PTR-MS sampled
300 <inline-formula><mml:math id="M73" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> from the auxiliary system.</p>
      <p id="d1e992">In SPS 2 a commercially built PTR-MS (Ionicon Analytik, GmbH, Innsbruck, Austria) was utilized for continuous VOC measurements. For
a detailed description of PTR-MS the reader is referred to Ellis and Mayhew (2014), de Gouw and Warneke (2007), and Lindinger
et al. (1998). Briefly, the instrument consists of a hollow cathode ion source where reagent ions were generated, a drift tube where the
reagent ions and the sample were mixed and chemical ionization reactions occurred between the reagent and the analytes, and
a quadrupole mass spectrometer (Balzers QMG422) with a secondary electron multiplier
operating in pulse counting mode, for
sorting and detecting reagent and product ions.</p>
      <p id="d1e995">The drift tube was operated at 60 <inline-formula><mml:math id="M74" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C with and an applied voltage of 445 <inline-formula><mml:math id="M75" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula> and a pressure of 2.16 <inline-formula><mml:math id="M76" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mbar</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula> Td). The PTR-MS quadrupole continuously scanned 181 masses between 14 and 200 <inline-formula><mml:math id="M78" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">amu</mml:mi></mml:mrow></mml:math></inline-formula> with a dwell time for a single mass
(<inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula>) of 1 <inline-formula><mml:math id="M80" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>, generating a full mass scan approximately every 3 <inline-formula><mml:math id="M81" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula> (20 datapoints <inline-formula><mml:math id="M82" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">h</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:msup><mml:mi>z</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e1115">Ambient sampling times from SPS 2 for the PTR-MS, AT-VOC and DNPH–HPLC methods; zero
and calibration times for the PTR-MS.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" namest="col2" nameend="col4" align="center">Ambient sampling </oasis:entry>
         <oasis:entry colname="col5">Zero</oasis:entry>
         <oasis:entry colname="col6">Calibration</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Morning</oasis:entry>
         <oasis:entry colname="col3">Afternoon</oasis:entry>
         <oasis:entry colname="col4">Night</oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">PTR-MS</oasis:entry>
         <oasis:entry colname="col2">05:00–10:00</oasis:entry>
         <oasis:entry colname="col3">11:00–16:45</oasis:entry>
         <oasis:entry colname="col4">19:00–23:45</oasis:entry>
         <oasis:entry colname="col5">23:45–00:15</oasis:entry>
         <oasis:entry colname="col6">00:15–0:45</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">17:15–19:00</oasis:entry>
         <oasis:entry colname="col4">00:45–05:00</oasis:entry>
         <oasis:entry colname="col5">16:45–17:15</oasis:entry>
         <oasis:entry colname="col6"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AT-VOC and DNPH</oasis:entry>
         <oasis:entry colname="col2">05:00–10:00</oasis:entry>
         <oasis:entry colname="col3">11:00–19:00</oasis:entry>
         <oasis:entry colname="col4">19:00–05:00</oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1236">The PTR-MS operated with the aid of custom-built auxiliary equipment that regulated the flow of air in the sample inlet and controlled
whether the PTR-MS was sampling ambient or zero air, or calibration gas. The timing and duration of zero, calibration and ambient
measurements for SPS 2 are detailed in Table 1. Zero readings were made by diverting ambient air through a zero furnace
(350 <inline-formula><mml:math id="M84" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) with a platinum wool catalyst that destroyed VOCs in the air before entering the PTR-MS. This zero air had the same
mole fractions of <inline-formula><mml:math id="M85" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M86" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> as the ambient air being sampled, neglecting minor contributions from the oxidation of
the VOCs present.</p>
      <p id="d1e1272">All PTR-MS ion signals from calibration and ambient measurements referred to in this study were background corrected.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e1278">The PTR-MS calibration factors for each of the VOCs included in this work, normalized to 10<inline-formula><mml:math id="M87" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">6</mml:mn></mml:msup></mml:math></inline-formula> counts per second (cps) of <inline-formula><mml:math id="M88" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> reagent ions per ppb (<inline-formula><mml:math id="M89" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ncps</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">ppbv</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) (average <inline-formula><mml:math id="M90" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> ion signal <inline-formula><mml:math id="M91" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">13.5</mml:mn></mml:mrow></mml:math></inline-formula> million cps). The uncertainty limits represent <inline-formula><mml:math id="M92" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> the standard deviation (<inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mi mathvariant="italic">σ</mml:mi></mml:mrow></mml:math></inline-formula>) of the daily mean in the calibration measurements over the campaign average. <inline-formula><mml:math id="M94" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> represents the number of 30 <inline-formula><mml:math id="M95" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula> calibration periods used to calculate the sensitivity statistics.
The average calibration for formaldehyde is presented in the table;
the ambient data processing for formaldehyde utilized a linear equation calibration factor <inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">16.08</mml:mn><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.232</mml:mn><mml:mo>⋅</mml:mo><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula>, where the water vapour concentration is in <inline-formula><mml:math id="M97" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">g</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">MW</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">Calibration factor</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M99" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ncps</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">ppbv</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Formaldehyde</oasis:entry>
         <oasis:entry colname="col2">30</oasis:entry>
         <oasis:entry colname="col3">31</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M100" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.36</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">21</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Acetaldehyde</oasis:entry>
         <oasis:entry colname="col2">44</oasis:entry>
         <oasis:entry colname="col3">45</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:mn mathvariant="normal">19.81</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Acetone</oasis:entry>
         <oasis:entry colname="col2">58</oasis:entry>
         <oasis:entry colname="col3">59</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:mn mathvariant="normal">24.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Isoprene</oasis:entry>
         <oasis:entry colname="col2">68</oasis:entry>
         <oasis:entry colname="col3">69</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mn mathvariant="normal">8.84</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">17</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Benzene</oasis:entry>
         <oasis:entry colname="col2">78</oasis:entry>
         <oasis:entry colname="col3">79</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mn mathvariant="normal">17.15</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Toluene</oasis:entry>
         <oasis:entry colname="col2">92</oasis:entry>
         <oasis:entry colname="col3">93</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mn mathvariant="normal">19.87</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M106" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-Xylene</oasis:entry>
         <oasis:entry colname="col2">106</oasis:entry>
         <oasis:entry colname="col3">107</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:mn mathvariant="normal">19.78</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1689">The minimum detectable limit (MDL) for each <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> scanned by the PTR-MS was determined from the scatter in the zero measurements using the
principles of ISO6879 (ISO, 1995). The MDL
for a single measurement was set at the 95th percentile of the deviations about the mean
zero. This is approximately equal to an <inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio <inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>. The PTR-MS was calibrated daily for 30 <inline-formula><mml:math id="M111" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula>. For each calibration
measurement a set flow of 10–20 <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> of the calibration standard was diluted in a flow 1500 <inline-formula><mml:math id="M113" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> of
ambient air that had been passed through the zero furnace. The empirically derived calibration factors for the seven compounds of interest
to this study, which were included in the calibration standards, are listed in the Table 2. The scatter (<inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mi mathvariant="italic">σ</mml:mi></mml:mrow></mml:math></inline-formula>) of the daily
mean in the calibration measurements over the campaign average was <inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> % (range 6–21 %).</p>
      <p id="d1e1792">The PTR-MS was calibrated with three certified gas standards containing in total 20 VOC species. These certified gas standards were
supplied by Apel-Riemer Environmental Inc. (Broomfield, CO, USA) and Air Liquide–Scott Specialty Gases (Plumsteadville, PA, USA). The
stated accuracy for each component in the standards was <inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> %.</p>
      <p id="d1e1805">The gravimetrically prepared Apel-Riemer standard used to calibrate the PTR-MS contained benzene, toluene and <inline-formula><mml:math id="M117" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-xylene, among other
components.  This standard was also analysed with the GC-FID-MS against a certified BTEX gas standard (Air Liquide–Scott Specialty
Gases) (manufacturer stated accuracy <inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> %). The FID response factors for the
two standards differed by 5–9 % (BTEX / Apel-Riemer ratios: benzene 0.95, toluene 0.95 and <inline-formula><mml:math id="M119" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-xylene 0.91) and we can conclude that the PTR-MS and GC-FID-MS calibrations were
compatible within these limits.</p>
      <p id="d1e1832">Interference in the identification and quantification of a target compound in PTR-MS measurements of ambient air can and frequently
does occur due to the presence of products from other reaction pathways such as isobaric compounds, fragment ions from other compounds,
isotopologues and products of secondary reactions (Warneke et al., 2003; Rogers et al., 2006; Inomata et al., 2008; Dunne et al., 2012;
Kaser et al., 2013). When comparing PTR-MS measurements to more selective VOC measurement techniques such as chromatographic methods,
the presence of interference in the target ion signal often results in an apparent positive bias in the PTR-MS reported values. The
uncertainty related to<?pagebreak page145?> mass interference is not incorporated in the bottom-up uncertainty analysis and is investigated here to
determine its role where there were significant differences at the 95 % confidence limit between the mean values measured by each
instrument.</p>
      <p id="d1e1835">If the identity of the interferents are known, and their concentration and PTR-MS response (fragmentation patterns and instrument
sensitivity) is also known or can be estimated, their contribution to the target <inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> can be quantified and subtracted (e.g. Rogers
et al., 2006; Inomata et al., 2008; Dunne et al., 2012). Where possible, for the compounds examined in this study, a method was
developed to correct the PTR-MS target ion signal for the presence of known and quantifiable interference. The correction procedure for
each compound examined here and the information used to quantify the correction are provided in the supplementary material. The
corrected and uncorrected PTR-MS reported values are discussed for each compound in Sect. 3.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e1853">The MDL and summary statistics (ppb) for the PTR-MS, AT-VOC and
DNPH data for each of the seven compounds selected for this study. Note that the
DNPH MDL differs between morning afternoon and night samples due to
different sampling times result. For the purposes of this table the DNPH
MDLs and median / MDLs are quoted as a range.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">MDL</oasis:entry>
         <oasis:entry colname="col4">25th percentile</oasis:entry>
         <oasis:entry colname="col5">Median</oasis:entry>
         <oasis:entry colname="col6">75th percentile</oasis:entry>
         <oasis:entry colname="col7">Median<inline-formula><mml:math id="M121" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M122" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">(ppb)</oasis:entry>
         <oasis:entry colname="col4">(ppb)</oasis:entry>
         <oasis:entry colname="col5">(ppb)</oasis:entry>
         <oasis:entry colname="col6">(ppb)</oasis:entry>
         <oasis:entry colname="col7">MDL</oasis:entry>
         <oasis:entry colname="col8"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Benzene</oasis:entry>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">0.005</oasis:entry>
         <oasis:entry colname="col4">0.20</oasis:entry>
         <oasis:entry colname="col5">0.36</oasis:entry>
         <oasis:entry colname="col6">0.69</oasis:entry>
         <oasis:entry colname="col7">72</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.003</oasis:entry>
         <oasis:entry colname="col4">0.28</oasis:entry>
         <oasis:entry colname="col5">0.48</oasis:entry>
         <oasis:entry colname="col6">0.89</oasis:entry>
         <oasis:entry colname="col7">160</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Toluene</oasis:entry>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">0.005</oasis:entry>
         <oasis:entry colname="col4">0.74</oasis:entry>
         <oasis:entry colname="col5">1.61</oasis:entry>
         <oasis:entry colname="col6">2.57</oasis:entry>
         <oasis:entry colname="col7">322</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.003</oasis:entry>
         <oasis:entry colname="col4">0.89</oasis:entry>
         <oasis:entry colname="col5">2.01</oasis:entry>
         <oasis:entry colname="col6">3.02</oasis:entry>
         <oasis:entry colname="col7">670</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M123" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> Aromatics</oasis:entry>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">0.008</oasis:entry>
         <oasis:entry colname="col4">0.58</oasis:entry>
         <oasis:entry colname="col5">1.04</oasis:entry>
         <oasis:entry colname="col6">1.89</oasis:entry>
         <oasis:entry colname="col7">130</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.003</oasis:entry>
         <oasis:entry colname="col4">0.68</oasis:entry>
         <oasis:entry colname="col5">1.33</oasis:entry>
         <oasis:entry colname="col6">2.23</oasis:entry>
         <oasis:entry colname="col7">443</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Isoprene</oasis:entry>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">0.002</oasis:entry>
         <oasis:entry colname="col4">0.09</oasis:entry>
         <oasis:entry colname="col5">0.13</oasis:entry>
         <oasis:entry colname="col6">0.22</oasis:entry>
         <oasis:entry colname="col7">65</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.014</oasis:entry>
         <oasis:entry colname="col4">0.35</oasis:entry>
         <oasis:entry colname="col5">0.51</oasis:entry>
         <oasis:entry colname="col6">0.80</oasis:entry>
         <oasis:entry colname="col7">36</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Formaldehyde</oasis:entry>
         <oasis:entry colname="col2">DNPH</oasis:entry>
         <oasis:entry colname="col3">0.025–0.051</oasis:entry>
         <oasis:entry colname="col4">0.72</oasis:entry>
         <oasis:entry colname="col5">0.96</oasis:entry>
         <oasis:entry colname="col6">1.20</oasis:entry>
         <oasis:entry colname="col7">18–44</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.212</oasis:entry>
         <oasis:entry colname="col4">0.81</oasis:entry>
         <oasis:entry colname="col5">1.04</oasis:entry>
         <oasis:entry colname="col6">1.47</oasis:entry>
         <oasis:entry colname="col7">5</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Acetaldehyde</oasis:entry>
         <oasis:entry colname="col2">DNPH</oasis:entry>
         <oasis:entry colname="col3">0.065–0.133</oasis:entry>
         <oasis:entry colname="col4">0.36</oasis:entry>
         <oasis:entry colname="col5">0.50</oasis:entry>
         <oasis:entry colname="col6">0.66</oasis:entry>
         <oasis:entry colname="col7">4–7</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.024</oasis:entry>
         <oasis:entry colname="col4">0.58</oasis:entry>
         <oasis:entry colname="col5">0.80</oasis:entry>
         <oasis:entry colname="col6">0.98</oasis:entry>
         <oasis:entry colname="col7">33</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Acetone</oasis:entry>
         <oasis:entry colname="col2">DNPH</oasis:entry>
         <oasis:entry colname="col3">0.069–0.142</oasis:entry>
         <oasis:entry colname="col4">0.39</oasis:entry>
         <oasis:entry colname="col5">0.61</oasis:entry>
         <oasis:entry colname="col6">0.92</oasis:entry>
         <oasis:entry colname="col7">5–9</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.013</oasis:entry>
         <oasis:entry colname="col4">1.09</oasis:entry>
         <oasis:entry colname="col5">1.49</oasis:entry>
         <oasis:entry colname="col6">1.93</oasis:entry>
         <oasis:entry colname="col7">115</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<?xmltex \hack{\newpage}?>
</sec>
<sec id="Ch1.S2.SS5">
  <label>2.5</label><title>Criteria for measurement comparisons</title>
      <p id="d1e2354">While a number of compounds were measured by both the PTR-MS and AT-VOC or DNPH techniques, only compounds whose data met the following
criteria were retained for the analysis:
<list list-type="order"><list-item>
      <p id="d1e2359">Each PTR-MS sample had an ambient data acquisition period that was <inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">90</mml:mn></mml:mrow></mml:math></inline-formula> % of the integrated sampling period of the AT-VOC
or DNPH for each sample.</p></list-item><list-item>
      <p id="d1e2373">Each compound known to substantially contribute to a given <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> signal in PTR-MS measurements of the atmosphere was also
measured in the AT-VOC and/or DNPH samples.</p></list-item><list-item>
      <p id="d1e2389">An empirical calibration from measurements of a certified standard containing the compound(s) of interest was available for both
techniques being compared.</p></list-item><list-item>
      <p id="d1e2393">The ratio of the median / MDL was <inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> for both datasets for the compounds being compared (Table 3). The relative error of most
measurement systems increases with decreasing volume mixing ratio (Horwitz, 1982; de Gouw and Warneke, 2007).
Using datasets with median / MDL <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula>
was considered suitable for a robust quantitative comparison. While values below the MDL are still retained for the analysis,
50 % of the data was <inline-formula><mml:math id="M128" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> times the MDL, ensuring the comparison is not dominated by random instrument noise.</p></list-item></list>
The averaging periods used to merge the PTR-MS, AT-VOC and DNPH data from SPS 2 are listed in Table 1. Three DNPH cartridges and three
pairs of VOC adsorbent tubes were collected daily: a 5 <inline-formula><mml:math id="M129" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula> sample collected in the morning (05:00–10:00), an 8 <inline-formula><mml:math id="M130" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula> sample
collected in the afternoon (11:00–19:00) and a 10 <inline-formula><mml:math id="M131" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula> sample collected over night (19:00–05:00). Three averages were determined
from PTR-MS data that corresponded with the three integrated sampling periods listed above (see Table 1).</p>
      <p id="d1e2451">Of the range of compounds measured by each of the three VOC measurement systems (PTR-MS, AT-VOC, DNPH), the data for seven
compounds or compound groups satisfied criteria 1, 2, 3 and 4 for inclusion in the inter-comparison presented here; they were benzene,
toluene, the <inline-formula><mml:math id="M132" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics, isoprene, formaldehyde, acetaldehyde and acetone.</p>
</sec>
<?pagebreak page146?><sec id="Ch1.S2.SS6">
  <label>2.6</label><title>Uncertainty in VOC measurements and inter-comparisons</title>
      <p id="d1e2473">There were two methods of determining uncertainties in VOC measurements assessed in this study, bottom-up and top-down. The first
approach, the bottom-up method, examined the individual components of a single measurement technique, assessed the uncertainty of each
and combined these to get a total uncertainty for that method (Harris, 2003; JCGM, 2008). The uncertainty analysis proceeded via the
mathematical model, here called the measurement equation, for the measurement as described in the Guide to Expression of Uncertainty in
Measurement (JCGM, 2008). Details of the uncertainty analysis procedure for each of the selected compounds and for the measurement
technique are described in the Supplement 1. All uncertainties in this analysis are expanded uncertainties with a coverage factor
<inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>, i.e. 2 standard deviations. The associated level of confidence of the uncertainty interval is typically 95 %.</p>
      <p id="d1e2488">The bottom-up uncertainty analysis for the AT-VOC method included uncertainty due to
<list list-type="bullet"><list-item>
      <p id="d1e2493">the accuracy of the certified calibration standards;</p></list-item><list-item>
      <p id="d1e2497">the variance in the response factors of the GC-FID in measurements of certified calibration gas
standards;</p></list-item><list-item>
      <p id="d1e2501">the uncertainty in the loop volume, temperature and pressure; and</p></list-item><list-item>
      <p id="d1e2505">the variance in a series of replicate ambient measurements of the target VOCs by the AT-VOC
method.</p></list-item></list>
The bottom-up uncertainty analysis for the DNPH method included uncertainty due to
<list list-type="bullet"><list-item>
      <p id="d1e2511">the accuracy of the certified calibration standards,</p></list-item><list-item>
      <p id="d1e2515">the variance in the response factors of the HPLC in measurements of a series of replicate DNPH cartridges spiked with a certified
liquid standard mixture and</p></list-item><list-item>
      <p id="d1e2519">the variance in a series of replicate ambient measurements of the target VOCs by the DNPH
method.</p></list-item></list>
The bottom-up uncertainty analysis for the PTR-MS method included uncertainty due to
<list list-type="bullet"><list-item>
      <p id="d1e2525">the accuracy of the certified calibration standards,</p></list-item><list-item>
      <p id="d1e2529">the variance in the performance of the mass flow controllers which were used to control the flows of the dilution and calibration
gas standards and</p></list-item><list-item>
      <p id="d1e2533">The variance in the response factors of the PTR-MS in measurements of certified calibration gas
standards.</p></list-item></list>
In the second approach to assessing uncertainty, the top-down method, we evaluated the systematic difference between two methods by
evaluating the slope and intercept of a linear regression between two sets of paired simultaneous measurements. We evaluate random
deviations of individual measurements as the root mean square of the orthogonal distance between the location of the pair of
observations (<inline-formula><mml:math id="M134" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M135" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula>) and the regression line for the whole dataset, here referred to as the root mean square of the deviations
(RMSD) (Harris, 2003).</p>
      <?pagebreak page147?><p id="d1e2551">When comparing two observational datasets, reduced major axis (RMA) regression, also called geometric mean regression, is preferable to
simple least squares linear regression because the analysis is not between an independent and dependent variable, and RMA accounts for
random measurement error on both the <inline-formula><mml:math id="M136" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M137" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> variables rather than only the <inline-formula><mml:math id="M138" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> variable (Kermack and Haldane, 1950; Ayers, 2001;
Franq and Govaerts, 2014). The RMA method is recommended when the measurement errors are unknown (Franq and Govaerts, 2014).</p>
      <p id="d1e2575">Contributions to the uncertainty of these measurements that are not included in the bottom-up analyses but are apparent from the
top-down analyses are discussed. These contributions are described as poorly understood and poorly quantified processes that do not
occur in the measurement equation. Some examples of these for PTR-MS and DNPH are identified. None were immediately apparent for
AT-VOC.</p>
      <p id="d1e2579">The results of this inter-comparison are compared with similar published studies from the scientific literature and some conclusions
about the uncertainty in current VOC measurements are presented. The other studies examined were published in the peer-reviewed
literature, in which all employed PTR-MS as one of the instruments being compared; only results of ambient air studies were included (direct
measurements of VOC emission sources such as biomass burning plumes were excluded) and in all comparisons both instruments were
calibrated for the species of interest.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results</title>
      <p id="d1e2591">Seven sets of inter-comparisons matched the criteria presented in Sect. 2.6. These were
<list list-type="bullet"><list-item>
      <p id="d1e2596">benzene, toluene, the sum of the <inline-formula><mml:math id="M139" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics and isoprene measured by
both the PTR-MS and the AT-VOC techniques in SPS 2 and</p></list-item><list-item>
      <p id="d1e2611">formaldehyde, acetaldehyde and acetone measured by both the PTR-MS and the
DNPH techniques in SPS 2.</p></list-item></list>
For simplicity, the subsequent text is organized around the names of the most common compound(s) occurring in the instrument response,
while the discussion recognizes that other interfering or co-eluting compounds can be contributing to the instrument response.</p>
      <p id="d1e2615">The MDL, summary statistics (25th percentile, median, 75th percentile) and the median / MDL for each compound are presented in Table 3.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e2621">The means and SDs of the atmospheric data;
the estimated measurement uncertainties of the means (<inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) (see
Supplement); the 95 % confidence limit of the means (ppb) for the seven
compounds measured by PTR-MS, AT-VOC and DNPH; and the number of paired observations, <inline-formula><mml:math id="M141" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula>, in this study.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Mean</oasis:entry>
         <oasis:entry colname="col4">SD</oasis:entry>
         <oasis:entry colname="col5">Rel. total</oasis:entry>
         <oasis:entry colname="col6">Mean <inline-formula><mml:math id="M142" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> uncertainty</oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M143" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">(ppb)</oasis:entry>
         <oasis:entry colname="col4">(ppb)</oasis:entry>
         <oasis:entry colname="col5">uncertainty of</oasis:entry>
         <oasis:entry colname="col6">(<inline-formula><mml:math id="M144" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) (ppb)</oasis:entry>
         <oasis:entry colname="col7"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5">mean (<inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) %</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Benzene</oasis:entry>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.59</oasis:entry>
         <oasis:entry colname="col4">0.38</oasis:entry>
         <oasis:entry colname="col5">11</oasis:entry>
         <oasis:entry colname="col6">0.53–0.65</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">0.45</oasis:entry>
         <oasis:entry colname="col4">0.30</oasis:entry>
         <oasis:entry colname="col5">12</oasis:entry>
         <oasis:entry colname="col6">0.40–0.50</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Toluene</oasis:entry>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">2.15</oasis:entry>
         <oasis:entry colname="col4">1.44</oasis:entry>
         <oasis:entry colname="col5">11</oasis:entry>
         <oasis:entry colname="col6">1.92–2.38</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">1.81</oasis:entry>
         <oasis:entry colname="col4">1.19</oasis:entry>
         <oasis:entry colname="col5">12</oasis:entry>
         <oasis:entry colname="col6">1.59–2.03</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M146" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics</oasis:entry>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">1.49</oasis:entry>
         <oasis:entry colname="col4">0.99</oasis:entry>
         <oasis:entry colname="col5">12</oasis:entry>
         <oasis:entry colname="col6">1.31–1.67</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">1.28</oasis:entry>
         <oasis:entry colname="col4">0.83</oasis:entry>
         <oasis:entry colname="col5">13</oasis:entry>
         <oasis:entry colname="col6">1.12–1.44</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Isoprene</oasis:entry>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.61</oasis:entry>
         <oasis:entry colname="col4">0.39</oasis:entry>
         <oasis:entry colname="col5">19</oasis:entry>
         <oasis:entry colname="col6">0.50–0.72</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">AT-VOC</oasis:entry>
         <oasis:entry colname="col3">0.24</oasis:entry>
         <oasis:entry colname="col4">0.32</oasis:entry>
         <oasis:entry colname="col5">7</oasis:entry>
         <oasis:entry colname="col6">0.22–0.26</oasis:entry>
         <oasis:entry colname="col7">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Formaldehyde</oasis:entry>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">1.27</oasis:entry>
         <oasis:entry colname="col4">0.71</oasis:entry>
         <oasis:entry colname="col5">22</oasis:entry>
         <oasis:entry colname="col6">0.99–1.55</oasis:entry>
         <oasis:entry colname="col7">53</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DNPH</oasis:entry>
         <oasis:entry colname="col3">1.07</oasis:entry>
         <oasis:entry colname="col4">0.59</oasis:entry>
         <oasis:entry colname="col5">9</oasis:entry>
         <oasis:entry colname="col6">0.98–1.16</oasis:entry>
         <oasis:entry colname="col7">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Acetaldehyde</oasis:entry>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">0.84</oasis:entry>
         <oasis:entry colname="col4">0.40</oasis:entry>
         <oasis:entry colname="col5">19</oasis:entry>
         <oasis:entry colname="col6">0.68–1.00</oasis:entry>
         <oasis:entry colname="col7">53</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DNPH</oasis:entry>
         <oasis:entry colname="col3">0.53</oasis:entry>
         <oasis:entry colname="col4">0.28</oasis:entry>
         <oasis:entry colname="col5">12</oasis:entry>
         <oasis:entry colname="col6">0.47–0.59</oasis:entry>
         <oasis:entry colname="col7">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Acetone</oasis:entry>
         <oasis:entry colname="col2">PTR-MS</oasis:entry>
         <oasis:entry colname="col3">1.69</oasis:entry>
         <oasis:entry colname="col4">1.04</oasis:entry>
         <oasis:entry colname="col5">22</oasis:entry>
         <oasis:entry colname="col6">1.32–2.06</oasis:entry>
         <oasis:entry colname="col7">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">DNPH</oasis:entry>
         <oasis:entry colname="col3">0.74</oasis:entry>
         <oasis:entry colname="col4">0.52</oasis:entry>
         <oasis:entry colname="col5">12</oasis:entry>
         <oasis:entry colname="col6">0.65–0.83</oasis:entry>
         <oasis:entry colname="col7">53</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e3125">The uncertainty associated with measurement of these VOCs is evaluated via the methods in the Guide to Expression of Uncertainty in
Measurement (JCGM, 2008) and presented in the Supplement. While there is some overlap between the observed uncertainty and the
calculated measurement uncertainty, they also include distinct components. The observed uncertainty of a set of atmospheric VOC
measurements includes a component due to atmospheric variability that is not included in the calculated uncertainty.  The calculated
measurement uncertainty can include a component due to uncertainty in the calibration standards, which does not occur in the observed
variability of atmospheric measurements which are measured against one reference standard.</p>
      <p id="d1e3128">Here we analyse whether the sets of simultaneous measurements of VOCs by two different methods have uncertainties such that their mean
values plus or minus the measurement uncertainties overlap within the 95 % confidence limit or not.  Table 4 shows that for benzene,
isoprene, acetaldehyde and acetone, the mean values do not overlap within the 95 % confidence limits. In contrast, for toluene,
xylenes and formaldehyde, the mean values do overlap within the 95 % confidence limits.</p>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Inter-comparison of PTR-MS and AT-VOC samples analysed by GC-FID-MS</title>
      <p id="d1e3138">The inter-comparisons for benzene, toluene, the sum of the <inline-formula><mml:math id="M147" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics and isoprene measured by both the PTR-MS and the
AT-VOC techniques are presented in Table 5 as the slope and intercept of the RMA regression analysis, correlation (<inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) and the
RMSD for each compound and scatterplots of the data are presented in Fig. 1a–e.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e3165">Intercomparisons of PTR-MS vs. AT-VOC and DNPH measurements of selected VOCs in SPS 2 (2012). RMA correlation coefficients
(<inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) and regression fits are indicated (solid line) plus or minus the
standard
error (dashed lines).</p></caption>
          <?xmltex \igopts{width=284.527559pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/141/2018/amt-11-141-2018-f01.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e3187"><bold>(a–c)</bold> Slopes, intercepts (ppbv)
and correlation coefficient from linear regression (<inline-formula><mml:math id="M150" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M151" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula>) analyses between
PTR-MS (<inline-formula><mml:math id="M152" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula>) and independent VOC measurement techniques (<inline-formula><mml:math id="M153" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula>) from this study (black squares) and other published studies (open
circles). BNZ – benzene;  TOL – toluene;  C8 – <inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics;  ISOP – isoprene;  FA – formaldehyde;  AA – acetaldehyde;  AC –
acetone. Note that grey squares are determined from analysis of isoprene afternoon data from this study. Grey diamonds are determined
from the analysis of DNPH acetone excluding periods affected by condensation (average dew point temperature <inline-formula><mml:math id="M155" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M156" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C). Published studies
used in this figure are referred to within the text for each compound Sects. 3.1.1–3.2.3.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/141/2018/amt-11-141-2018-f02.pdf"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3" specific-use="star"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e3260">Time series of <bold>(a)</bold> formaldehyde, <bold>(b)</bold> acetaldehyde and <bold>(c)</bold> acetone measured in the DNPH samples and
by the PTR-MS in SPS 2. Also shown is the <bold>(d)</bold> time series of the DNPH reported acetone concentration and
extraction mass and <bold>(e)</bold> the DNPH extraction masses plotted vs. dew point along with the ratio of
DNPH reported acetone data to the PTR-MS reported acetone data (DNPH[acetone]<inline-formula><mml:math id="M157" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula>PTR-MS[acetone] plotted vs. dew point).</p></caption>
          <?xmltex \igopts{width=284.527559pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/141/2018/amt-11-141-2018-f03.pdf"/>

        </fig>

<sec id="Ch1.S3.SS1.SSS1">
  <label>3.1.1</label><title>Benzene</title>
      <p id="d1e3299">In PTR-MS, protonated benzene is detected at <inline-formula><mml:math id="M158" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79. The comparisons presented in Table 4 indicate a significant difference at the
95 % confidence limit between the mean values measured by the PTR-MS at <inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 and the benzene reported by the AT-VOC method.</p>
      <p id="d1e3326">Reduced major axis regression analysis between the PTR-MS data for <inline-formula><mml:math id="M160" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 and the AT-VOC benzene data yielded a slope of <inline-formula><mml:math id="M161" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.47</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M163" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M165" display="inline"><mml:mn mathvariant="normal">0.96</mml:mn></mml:math></inline-formula> (Fig. 1a). The high <inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> value and small
RMSD of <inline-formula><mml:math id="M167" display="inline"><mml:mn mathvariant="normal">0.04</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M168" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> (RMSD / median <inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula> %) (Table 5, Fig. 1a)
indicates the AT-VOC and PTR-MS were both responding to
benzene.</p>
      <p id="d1e3428">It is possible the slope of <inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn></mml:mrow></mml:math></inline-formula> was a result of contributions to the PTR-MS signal at <inline-formula><mml:math id="M171" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 from compounds other than
benzene, such as fragment ions from ethylbenzene, propyl- and isopropyl-benzene,
and butyl- and isobutyl-benzene which can potentially
contribute to the signal at <inline-formula><mml:math id="M172" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 (Warneke et al., 2003; Gueneron et al., 2015). In addition, an unknown
C<inline-formula><mml:math id="M173" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M174" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula><inline-formula><mml:math id="M175" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">H</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> ion signal was detected at <inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 by high-resolution proton-transfer-reaction time-of-flight mass
spectrometry (PTR-ToF-MS) in a rural atmosphere
(Park et al., 2013).</p>
      <p id="d1e3509">Ethylbenzene was measured in the AT-VOC samples; however, propyl- and isopropyl benzene were not, and their contribution to the PTR-MS
ion signal at <inline-formula><mml:math id="M177" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 could not be assessed. Using the AT-VOC data for ethylbenzene and literature values of the ethylbenzene and
benzene PTR-MS response variables – branching ratios (Gueneron et al., 2015)<?pagebreak page148?> and ionization reaction rates (Cappellin et al., 2012) –
a correction was applied to the PTR-MS <inline-formula><mml:math id="M178" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 data to subtract interference due to the presence of fragment ion signals from
ethylbenzene. This correction procedure is described in detail in the Supplement Sect. S.2.</p>
      <p id="d1e3537">The slope of the RMA regression between the corrected PTR-MS data and the AT-VOC data improved slightly to <inline-formula><mml:math id="M179" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.36</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula> (intercept
<inline-formula><mml:math id="M180" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M181" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.96</mml:mn></mml:mrow></mml:math></inline-formula>), indicating ethylbenzene made a minor but measurable contribution to the PTR-MS signal at <inline-formula><mml:math id="M182" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79
in this study.</p>
      <p id="d1e3593">The quantitative agreement between the measurement of benzene by PTR-MS and AT-VOC in this study was poorer than those reported in
similar real-world inter-comparisons, most of which have reported slopes between 0.8 and 1.2 shown graphically in Fig. 2 (Warneke
et al., 2001; de Gouw et al., 2003; Kato et al., 2004; Kuster et al., 2004; Jobson et al., 2010; Rogers et al., 2006; de Gouw and
Warneke, 2007; Kaser et al., 2013; Wang et al., 2014; Kajos et al., 2015; Cui et al., 2016).</p>
      <p id="d1e3596">The degree of interference will vary with the relative concentrations of higher aromatics to benzene in the atmosphere being
studied. As the higher aromatics have shorter atmospheric lifetimes than benzene, the interference will vary with ageing of an air
mass. Thus, when measuring aged air masses, PTR-MS reported values should show better agreement with more selective GC techniques. In
this study, within a large city, fresh emissions would be present, containing on average a greater fraction of higher aromatics. Thus, we
would expect a larger contribution to the <inline-formula><mml:math id="M183" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 79 signal from fragment ions of higher aromatics.</p>
      <p id="d1e3611">In summary, a comparison between the measurements of benzene by PTR-MS and the AT-VOC technique indicates a significant difference in
the measured concentrations which is unresolved but is likely to vary according to the relative contribution of higher aromatics in
different atmospheres.</p>
</sec>
<sec id="Ch1.S3.SS1.SSS2">
  <label>3.1.2</label><title>Toluene</title>
      <p id="d1e3622">In PTR-MS, toluene undergoes non-dissociative proton transfer from <inline-formula><mml:math id="M184" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> producing a single ion signal at <inline-formula><mml:math id="M185" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 93
(Gueneron et al., 2015). The comparisons presented in Table 4 indicate no difference between mean values measured by PTR-MS and AT-VOC
methods at the 95 % confidence limit.</p>
      <p id="d1e3653">RMA regression analysis between the PTR-MS data at <inline-formula><mml:math id="M186" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 93 and the AT-VOC data for toluene yielded a slope of <inline-formula><mml:math id="M187" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of  <inline-formula><mml:math id="M188" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M190" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M191" display="inline"><mml:mn mathvariant="normal">0.98</mml:mn></mml:math></inline-formula> (Table 5, Fig. 1b). The RMSD was 0.11 <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula>,
which was only 5 % of the median PTR-MS value (Table 5). The high <inline-formula><mml:math id="M193" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> value and small RMSD indicates the PTR-MS signal at <inline-formula><mml:math id="M194" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 93 was
dominated by toluene.</p>
      <p id="d1e3752">The <inline-formula><mml:math id="M195" display="inline"><mml:mrow><mml:mtext>slope</mml:mtext><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> may be a result of contributions to the PTR-MS signal at <inline-formula><mml:math id="M196" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 93 from compounds other than toluene. These
include <inline-formula><mml:math id="M197" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>- and <inline-formula><mml:math id="M198" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-pinene, <inline-formula><mml:math id="M199" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-cymene and several <inline-formula><mml:math id="M200" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics (ethyltoluenes, 1,2,3-trimethylbenzene), all of
which are known to produce fragment ions at <inline-formula><mml:math id="M201" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 93 in PTR-MS (Warneke et al., 2003; Maleknia et al., 2007; Ambrose et al., 2010;
Gueneron et al., 2015).</p>
      <?pagebreak page149?><p id="d1e3824">These potential interferent compounds, with the exception of <inline-formula><mml:math id="M202" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-ethyltoluene and 1,2,3-trimethylbenzene, were measured in the AT-VOC
samples. Using the AT-VOC data for <inline-formula><mml:math id="M203" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>- and <inline-formula><mml:math id="M204" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-pinene, <inline-formula><mml:math id="M205" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-cymene, and <inline-formula><mml:math id="M206" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>- and <inline-formula><mml:math id="M207" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-ethyltoluene, as well as literature values of
their PTR-MS response variables – branching ratios (Gueneron et al., 2015) and ionization reaction rates (Cappellin et al., 2012) –
a correction was applied to the PTR-MS <inline-formula><mml:math id="M208" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 93 data to subtract interference due to the presence of fragment ion signals from these
interferents. This correction procedure is described in detail in the Supplement Sect. S.2.</p>
      <p id="d1e3883">This correction had a minor impact on the slope of the RMA regression (<inline-formula><mml:math id="M209" display="inline"><mml:mrow><mml:mtext>slope</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.21</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula>,
intercept <inline-formula><mml:math id="M210" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M211" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.98</mml:mn></mml:mrow></mml:math></inline-formula>) and the reason for the remaining discrepancy was unresolved.</p>
      <p id="d1e3933">With the exception of two of studies (Kato et al., 2004; Kajos et al., 2015) previous inter-comparisons between toluene measurements by
PTR-MS and GC techniques have reported slopes of 0.8–1.2 and generally good correlations<?pagebreak page150?> (<inline-formula><mml:math id="M212" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0.75</mml:mn></mml:mrow></mml:math></inline-formula>) (Fig. 2.) (Warneke et al.,
2001; de Gouw et al., 2003; Kuster et al., 2004; de Gouw and Warneke, 2007; Kaser et al., 2013; Wang et al., 2014; Kajos et al., 2015;
Cui et al., 2016).</p>
      <p id="d1e3951">In summary, a comparison between the measurements of toluene by PTR-MS and the AT-VOC technique indicates that there was not
a significant difference in the measured concentrations at the 95 % confidence limit. There may be some residual unquantified
interference with the PTR-MS toluene measurement which may vary due to contributions from the many additional monoterpene species
commonly present in the atmosphere but not accounted for here (Geron et al., 2000; Maleknia et al., 2007).</p>
</sec>
<sec id="Ch1.S3.SS1.SSS3">
  <label>3.1.3</label><?xmltex \opttitle{{$\protect\chem{C_{{8}}}$} aromatics}?><title><inline-formula><mml:math id="M213" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics</title>
      <p id="d1e3973">In PTR-MS, the signal at <inline-formula><mml:math id="M214" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 107 is commonly regarded as a measure of the sum of the <inline-formula><mml:math id="M215" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatic isomers (
<inline-formula><mml:math id="M216" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-, <inline-formula><mml:math id="M217" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>-, <inline-formula><mml:math id="M218" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-xylenes and ethylbenzene) (de Gouw and Warneke, 2007). The comparisons presented in Table 4 indicate no difference between mean values
of the sum of the <inline-formula><mml:math id="M219" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatic isomers measured by the PTR-MS and AT-VOC techniques at the 95 % confidence
limit; however, as observed for benzene and toluene, there appears to be a systematic difference between the two methods.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T5" specific-use="star"><?xmltex \currentcnt{5}?><label>Table 5</label><caption><p id="d1e4035">The slope (<inline-formula><mml:math id="M220" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>), intercepts (<inline-formula><mml:math id="M221" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula>) and correlation coefficients (<inline-formula><mml:math id="M222" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) from the RMA regression analysis between the PTR-MS, AT-VOC and
DNPH–HPLC measurements. Also included are the estimates of random measurement uncertainty expressed as RMSD for each species and the ratio of the RMSD to the median PTR-MS value expressed as a percentage (%).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M223" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Compound</oasis:entry>
         <oasis:entry colname="col3">Slope</oasis:entry>
         <oasis:entry colname="col4">Intercept</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M224" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">RMSD</oasis:entry>
         <oasis:entry colname="col7">RMSD<inline-formula><mml:math id="M225" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M226" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">(<inline-formula><mml:math id="M227" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col4">(<inline-formula><mml:math id="M228" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula>) (ppbv)</oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6">(ppbv)</oasis:entry>
         <oasis:entry colname="col7">median</oasis:entry>
         <oasis:entry colname="col8"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry namest="col1" nameend="col8" align="center"><inline-formula><mml:math id="M229" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mtext>PTR-MS</mml:mtext><mml:mo>]</mml:mo><mml:mo>=</mml:mo><mml:mi>m</mml:mi><mml:mo>×</mml:mo><mml:mo>[</mml:mo><mml:mtext>AT-VOC</mml:mtext><mml:mo>]</mml:mo><mml:mo>+</mml:mo><mml:mi>b</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">79</oasis:entry>
         <oasis:entry colname="col2">Benzene (uncorr.)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M230" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.47</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M231" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.96</oasis:entry>
         <oasis:entry colname="col6">0.04</oasis:entry>
         <oasis:entry colname="col7">8 %</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Benzene (corr.)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M232" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.36</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M233" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.96</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">93</oasis:entry>
         <oasis:entry colname="col2">Toluene (uncorr.)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M234" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M235" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.98</oasis:entry>
         <oasis:entry colname="col6">0.11</oasis:entry>
         <oasis:entry colname="col7">5 %</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Toluene (corr.)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M236" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.21</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M237" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.98</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">107</oasis:entry>
         <oasis:entry colname="col2">C<inline-formula><mml:math id="M238" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:math></inline-formula> aromatics (uncorr.)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M239" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.16</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M240" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.98</oasis:entry>
         <oasis:entry colname="col6">0.09</oasis:entry>
         <oasis:entry colname="col7">7 %</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">C<inline-formula><mml:math id="M241" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:math></inline-formula> aromatics (corr.)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M242" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.16</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M243" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.98</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">69</oasis:entry>
         <oasis:entry colname="col2">Isoprene (all)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M244" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.23</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M245" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.31</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.10</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.75</oasis:entry>
         <oasis:entry colname="col6">0.13</oasis:entry>
         <oasis:entry colname="col7">24 %</oasis:entry>
         <oasis:entry colname="col8">75</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Isoprene (05:00–10:00)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M246" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.86</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.32</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M247" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.28</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.16</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.34</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Isoprene (11:00–19:00)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M248" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.18</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M249" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.11</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.10</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.93</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Isoprene (19:00–05:00)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M250" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.18</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.10</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M251" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.41</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.33</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.83</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry namest="col1" nameend="col8" align="center"><inline-formula><mml:math id="M252" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mtext>PTR-MS</mml:mtext><mml:mo>]</mml:mo><mml:mo>=</mml:mo><mml:mi>m</mml:mi><mml:mo>×</mml:mo><mml:mo>[</mml:mo><mml:mtext>DNPH–HPLC</mml:mtext><mml:mo>]</mml:mo><mml:mo>+</mml:mo><mml:mi>b</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">31</oasis:entry>
         <oasis:entry colname="col2">Formaldehyde (uncorr.)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M253" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M254" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.04</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.90</oasis:entry>
         <oasis:entry colname="col6">0.15</oasis:entry>
         <oasis:entry colname="col7">14 %</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Formaldehyde (corr)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M255" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.17</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M256" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.88</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">45</oasis:entry>
         <oasis:entry colname="col2">Acetaldehyde</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M257" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.43</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M258" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.08</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.92</oasis:entry>
         <oasis:entry colname="col6">0.05</oasis:entry>
         <oasis:entry colname="col7">6 %</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">59</oasis:entry>
         <oasis:entry colname="col2">Acetone</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M259" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.01</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M260" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.21</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.76</oasis:entry>
         <oasis:entry colname="col6">0.23</oasis:entry>
         <oasis:entry colname="col7">15 %</oasis:entry>
         <oasis:entry colname="col8">53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Acetone (Tdp <inline-formula><mml:math id="M261" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 7 <inline-formula><mml:math id="M262" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M263" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M264" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.22</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0.89</oasis:entry>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">12</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e4987">RMA regression analysis between the PTR-MS signal at <inline-formula><mml:math id="M265" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 107 (ppb) and the AT-VOC data for the sum of the <inline-formula><mml:math id="M266" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics
yielded a slope of <inline-formula><mml:math id="M267" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.16</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M268" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M269" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M270" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M271" display="inline"><mml:mn mathvariant="normal">0.98</mml:mn></mml:math></inline-formula> (Table 5, Fig. 1c). The RMSD of
0.09 <inline-formula><mml:math id="M272" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> was only 7 % of the median PTR-MS value (Table 5), which when combined with the high <inline-formula><mml:math id="M273" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> value indicates
both techniques were responding to the <inline-formula><mml:math id="M274" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics.</p>
      <p id="d1e5097">The concentration of <inline-formula><mml:math id="M275" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics detected by the PTR-MS at <inline-formula><mml:math id="M276" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 107 was quantified using a calibration factor of
19.78 <inline-formula><mml:math id="M277" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ncps</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">ppbv</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> that was determined from measurements of a certified gas standard containing <inline-formula><mml:math id="M278" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-xylene. Unlike <inline-formula><mml:math id="M279" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-, <inline-formula><mml:math id="M280" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>- and
<inline-formula><mml:math id="M281" display="inline"><mml:mi>o</mml:mi></mml:math></inline-formula>-xylene, ethylbenzene undergoes fragmentation in the PTR-MS, and at the operating conditions used in this study <inline-formula><mml:math id="M282" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">90</mml:mn></mml:mrow></mml:math></inline-formula> % of
the ethylbenzene ion signal occurs at <inline-formula><mml:math id="M283" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 107 (Gueneron et al., 2015). Consequently, using a calibration factor based on <inline-formula><mml:math id="M284" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-xylene
alone will lead to an underestimation by PTR-MS when quantifying the sum of the <inline-formula><mml:math id="M285" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatic isomers from the signal at <inline-formula><mml:math id="M286" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula>
107. Using the AT-VOC data to determine the relative abundance of the <inline-formula><mml:math id="M287" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatic isomers in the atmosphere as well as
literature values of their PTR-MS response variables – branching ratios (Gueneron et al., 2015) and ionization reaction rates (Cappellin
et al., 2012) – a corrected calibration factor of 19.61 <inline-formula><mml:math id="M288" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ncps</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">ppbv</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> was applied to the PTR-MS <inline-formula><mml:math id="M289" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 107 data to correct
for the presence of ethylbenzene. The correction procedure is described in detail in the Supplement Sect. S.2.</p>
      <p id="d1e5262">This correction resulted in a minor increase in the slope to <inline-formula><mml:math id="M290" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.19</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula>, with an intercept of
<inline-formula><mml:math id="M291" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M292" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M293" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M294" display="inline"><mml:mn mathvariant="normal">0.98</mml:mn></mml:math></inline-formula>.</p>
      <?pagebreak page151?><p id="d1e5317">A minor contribution to the PTR-MS signal at <inline-formula><mml:math id="M295" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 107 may occur due to the presence of protonated benzaldehyde (de Gouw and Warneke,
2007), which was measured by the DNPH method in this study and comprised 2 % on average (range 0–5 %) of the sum of the
<inline-formula><mml:math id="M296" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics reported by AT-VOC. Subtracting the concentration of benzaldehyde from the PTR-MS signal at <inline-formula><mml:math id="M297" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 107 had no
effect on the slope of the RMA regression (slope <inline-formula><mml:math id="M298" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.16</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M299" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.98</mml:mn></mml:mrow></mml:math></inline-formula>) and resulted in a minor
increase in the negative offset (intercept <inline-formula><mml:math id="M300" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M301" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>) (see Supplement S.2).</p>
      <p id="d1e5403">The results reported here are similar to many previous intercomparison studies that have reported good quantitative agreement, within
<inline-formula><mml:math id="M302" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>20 % (<inline-formula><mml:math id="M303" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0.85</mml:mn></mml:mrow></mml:math></inline-formula>), between PTR-MS and GC techniques for the measurement of the sum of the <inline-formula><mml:math id="M304" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics (Warneke
et al., 2001; Kuster et al., 2004; Jobson et al., 2010; Rogers et al., 2006; de Gouw and Warneke, 2007; Wang et al., 2014; Cui et al.,
2016). However, slopes as low as 0.6 (Kato et al., 2004) and as high as 3.2 (de Gouw et al., 2003) have been reported with the
discrepancy in both cases, which is attributable to calibration inaccuracies.</p>
      <p id="d1e5439">In summary, a comparison between the measurements of <inline-formula><mml:math id="M305" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics by PTR-MS and the AT-VOC technique indicates that there was
not a significant difference in the measured concentrations. There may be some residual unquantified interference with the PTR-MS
<inline-formula><mml:math id="M306" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatic measurement.</p>
</sec>
<?pagebreak page152?><sec id="Ch1.S3.SS1.SSS4">
  <label>3.1.4</label><title>Isoprene</title>
      <p id="d1e5472">In measurements of the atmosphere the PTR-MS signal at <inline-formula><mml:math id="M307" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69 is attributed
to isoprene. The RMA regression analysis between the PTR-MS and AT-VOC data
for isoprene yielded a slope of <inline-formula><mml:math id="M308" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.23</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M309" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.31</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.10</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M310" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M311" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M312" display="inline"><mml:mn mathvariant="normal">0.75</mml:mn></mml:math></inline-formula>
(Fig. 1d). The lower <inline-formula><mml:math id="M313" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> and higher RMSD of 0.13 <inline-formula><mml:math id="M314" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> (Fig. 1d, Table 5) observed for isoprene indicate
the two instruments may not have been responding entirely to the same
compounds (Fig. 1d). The comparisons presented in Table 4 indicate
a significant difference at the 95 % confidence limit between the mean
values measured by each instrument.</p>
      <p id="d1e5557">Isoprene emissions are dominated by biogenic sources and are strongly light and temperature dependent with maxima in the afternoon. For
SPS 2, when only the afternoon data were considered, closer agreement was observed between the PTR-MS and AT-VOC data for isoprene
attributed to a 0.2 <inline-formula><mml:math id="M315" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> lower intercept (<inline-formula><mml:math id="M316" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.11</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.10</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M317" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula>) and significantly higher <inline-formula><mml:math id="M318" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of 0.93
(<inline-formula><mml:math id="M319" display="inline"><mml:mrow><mml:mtext>slope</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.18</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula>, RMSD <inline-formula><mml:math id="M320" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M321" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>) (Table 5, Fig. 1e).  There is no significant correlation between AT-VOC
isoprene and the PTR-MS signal at <inline-formula><mml:math id="M322" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69 for the period 05:00–10:00 (<inline-formula><mml:math id="M323" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.34</mml:mn></mml:mrow></mml:math></inline-formula>), rendering the RMA slope and intercept
essentially meaningless. There is a slope of 1.18 and offset of 0.41 <inline-formula><mml:math id="M324" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> in the RMA regression for the period 19:00–05:00
(R2 <inline-formula><mml:math id="M325" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.83</mml:mn></mml:mrow></mml:math></inline-formula>), indicating that other compounds may be contributing to the PTR-MS signal at <inline-formula><mml:math id="M326" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69 and their relative
contribution is largest at night and in the early hours of the morning when isoprene concentrations are lowest.</p>
      <p id="d1e5692">Park et al. (2013) observed three peaks at <inline-formula><mml:math id="M327" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69 in high-resolution PTR-ToF-MS spectra in a rural area: <inline-formula><mml:math id="M328" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">H</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M329" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> %), <inline-formula><mml:math id="M330" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>O<inline-formula><mml:math id="M331" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">H</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M332" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">14</mml:mn></mml:mrow></mml:math></inline-formula> %) and <inline-formula><mml:math id="M333" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">H</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M334" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">75</mml:mn></mml:mrow></mml:math></inline-formula> %). PTR-ToF-MS measurements also
identified dimethylcyclohexane and cyclopentene at <inline-formula><mml:math id="M335" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69 in air impacted by evaporative fuel emissions (Yuan et al., 2014). GC-PTR-MS
analysis has also shown multiple other species can contribute to <inline-formula><mml:math id="M336" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69, specifically 2- and 3-methylbutanal, and 1-penten-3-ol in urban
air (de Gouw et al., 2003); furan in air masses impacted by biomass burning (Christian et al., 2004); and 2-methyl-3-buten-2-ol in air
masses impacted by emissions from pine trees (Karl et al., 2012). Unfortunately independent measurements of these interferent compounds
are not available for this study and their contributions to the PTR-MS signal <inline-formula><mml:math id="M337" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69 cannot be estimated.</p>
      <p id="d1e5848">The results reported here are consistent with previous inter-comparisons studies between PTR-MS and GC techniques which have reported
slopes of 0.79–2.15 often with significant (up to 0.39 <inline-formula><mml:math id="M338" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula>) offsets, shown graphically in Fig. 2 (de Gouw et al., 2003; Kato
et al., 2004; Kuster et al., 2004; Wang et al., 2004; de Gouw and Warneke, 2007; Kaser et al., 2013).</p>
      <p id="d1e5860">In summary, a comparison between the measurements of isoprene by PTR-MS and the AT-VOC technique indicates a significant difference in
the measured concentrations which may vary according to the relative contribution of other species that contribute to the PTR-MS signal
at <inline-formula><mml:math id="M339" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 69<?pagebreak page153?> particularly at night. The influence of these compounds on measurements of isoprene by PTR-MS, while well known, are not
quantified in the bottom-up measurement uncertainty analysis of the PTR-MS technique.</p>
</sec>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Intercomparison of PTR-MS with DNPH derivatization–HPLC</title>
      <p id="d1e5884">In the following section, the inter-comparisons for formaldehyde, acetaldehyde and acetone measured by both the PTR-MS and the
DNPH–HPLC techniques in SPS 2 will be discussed in turn. The MDL, summary statistics (25th percentile, median, 75th percentile) and the
median / MDL values for the PTR-MS and DNPH data for each compound are presented in Table 3. The results of the analysis of measurement
uncertainty are presented in Table 4.</p>
      <p id="d1e5887">The results of the RMA regression analysis and the RMSD for each compound are summarized in Table 5. Scatterplots of the comparisons
for the three carbonyl compounds are presented in Fig. 1f–h.</p>
      <p id="d1e5890">As part of this analysis, we have identified a loss process in the DNPH method due to condensation of <inline-formula><mml:math id="M340" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> in the cartridges. To
explain this loss, some detail of the measurement technique is necessary. The compartment housing the DNPH cartridges in the automated
sampler was maintained at <inline-formula><mml:math id="M341" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M342" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and the cartridges were refrigerated before and after sampling. Liquid water was
observed in the some cartridges on retrieval and it was assumed the additional mass was due to the condensation of water from ambient
air in the chilled DNPH cartridge during sampling. The derivatized carbonyl compounds on the DNPH cartridge samples are extracted with
a fixed volume of acetonitrile after air sampling and prior to HPLC analysis. The volume of acetonitrile used in the extraction is
determined beforehand and the mass of extract afterwards. For the period 16–24 April, the extraction masses (g) were <inline-formula><mml:math id="M343" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> %
higher than the volume of acetonitrile added in the extraction and also higher than the extraction masses for other sample and blank
cartridges analysed in this study (Fig. 3d). Typically the mass of the DNPH cartridge extraction is <inline-formula><mml:math id="M344" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">2.0</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M345" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">g</mml:mi></mml:mrow></mml:math></inline-formula>. At dew point
temperatures <inline-formula><mml:math id="M346" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M347" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C the mass of the extraction from the DNPH cartridge was observed to be higher (<inline-formula><mml:math id="M348" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">2.1</mml:mn></mml:mrow></mml:math></inline-formula>–2.4 <inline-formula><mml:math id="M349" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">g</mml:mi></mml:mrow></mml:math></inline-formula>)
(Fig. 3e). The presence of liquid water appears to substantially reduce the collection efficiency of acetone with
concentrations <inline-formula><mml:math id="M350" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> MDL as shown in Fig. 3d, which would be extremely unlikely in an urban area and point to a significant measurement
issue. To investigate the effect of condensation in the cartridges, the DNPH data for formaldehyde, acetaldehyde and acetone including
and excluding the period 16–24 April were analysed separately and are discussed below.</p>
      <p id="d1e5998">The inter-comparisons for formaldehyde, acetaldehyde and acetone measured by both the PTR-MS and the DNPH techniques are presented in
Table 5 as the slope and intercept of the RMA regression analysis, correlation (<inline-formula><mml:math id="M351" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) and the RMSD for each compound and
scatterplots of the data are presented in Fig. 1f–h.</p>
<sec id="Ch1.S3.SS2.SSS1">
  <label>3.2.1</label><title>Formaldehyde</title>
      <p id="d1e6020">In PTR-MS, protonated formaldehyde is detected at <inline-formula><mml:math id="M352" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 31 (Hansel et al., 1997). The measurement of formaldehyde with PTR-MS is complex
as its proton transfer chemical ionization reaction with <inline-formula><mml:math id="M353" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is close to endothermic and loss via back reaction in humid
air is non-negligible (Hansel et al., 1997; Inomata et al., 2008). In order to account for the water vapour dependence of the PTR-MS
response to formaldehyde, daily instrument background and calibration measurements were made using zero air that had the same mole
fractions of <inline-formula><mml:math id="M354" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> as the ambient air being sampled. The linear relationship observed between the formaldehyde calibration
factors measured daily and the respective water vapour density (<inline-formula><mml:math id="M355" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">g</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) was determined, and a corrected calibration factor
was applied to the ambient hourly data based on the ambient water vapour density measured hourly.</p>
      <p id="d1e6081">The comparisons presented in Table 4 indicate that the mean values reported by PTR-MS and DNPH agree within 95 % confidence
limits. RMA regression analysis between the PTR-MS signal at <inline-formula><mml:math id="M356" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 31 and the formaldehyde in the DNPH–HPLC samples yielded a slope of
<inline-formula><mml:math id="M357" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.30</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M358" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M359" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>, an <inline-formula><mml:math id="M360" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M361" display="inline"><mml:mn mathvariant="normal">0.92</mml:mn></mml:math></inline-formula>
and an RMSD of <inline-formula><mml:math id="M362" display="inline"><mml:mn mathvariant="normal">0.14</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M363" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M364" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">77</mml:mn></mml:mrow></mml:math></inline-formula>). The high <inline-formula><mml:math id="M365" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>
value gives confidence that both the PTR-MS and the DNPH technique were both responding to formaldehyde.</p>
      <p id="d1e6187">To examine any possible effect of liquid water, the analysis was repeated excluding the data of 16–24 April. The results yielded
a slope of <inline-formula><mml:math id="M366" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M367" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.04</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M368" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>, an <inline-formula><mml:math id="M369" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M370" display="inline"><mml:mn mathvariant="normal">0.90</mml:mn></mml:math></inline-formula>
and an RMSD of <inline-formula><mml:math id="M371" display="inline"><mml:mn mathvariant="normal">0.15</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M372" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M373" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">53</mml:mn></mml:mrow></mml:math></inline-formula>) (Table 5
and Fig. 1f), indicating a minor but significant effect of liquid water.</p>
      <p id="d1e6268">The slope of 1.25 may be a result of contributions to the PTR-MS signal at <inline-formula><mml:math id="M374" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 31 from compounds other than formaldehyde, including
methanol, ethanol, and methyl hydroperoxide (Inomata et al., 2008) and glyoxal (Stonner et al., 2016). The protonated molecular ion
signal of ethanol and methyl hydroperoxide cannot be unequivocally identified in the PTR-MS spectra and their concentrations were not
determined independently by either the AT-VOC or DNPH method, and consequently their contribution to the <inline-formula><mml:math id="M375" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 31 signal cannot be
determined in this study.</p>
      <p id="d1e6296">The dominant ion signal in the PTR-MS spectra of glyoxal is detected at <inline-formula><mml:math id="M376" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 31 due to strong fragmentation of the parent ion (Stonner
et al., 2016). However, these authors also found that, like formaldehyde, glyoxal also has a low proton affinity and loss
via back reaction in humid air is also non-negligible, resulting in a very low PTR-MS sensitivity of <inline-formula><mml:math id="M377" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">0.3</mml:mn></mml:mrow></mml:math></inline-formula>–0.8 <inline-formula><mml:math id="M378" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ncps</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">ppbv</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> compared to
a formaldehyde sensitivity of <inline-formula><mml:math id="M379" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1.4</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M380" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ncps</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">ppbv</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for this study.</p>
      <p id="d1e6365">Using the PTR-MS and DNPH data for methanol and glyoxal respectively, along with laboratory measurements<?pagebreak page154?> and literature values of the
PTR-MS response variables for formaldehyde, methanol and glyoxal – branching ratios (BR<inline-formula><mml:math id="M381" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>) (Dunne, 2016; Stonner et al., 2016) and
reaction rates (Cappellin et al., 2012) – a correction was applied to the PTR-MS <inline-formula><mml:math id="M382" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 31 data to subtract interference in the
measurement of formaldehyde due to the presence of fragment ions from methanol and glyoxal. This correction procedure is described in
detail in the Supplement Sect. S.2. Applying the correction for methanol and glyoxal interference to the reduced <inline-formula><mml:math id="M383" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 31 dataset (<inline-formula><mml:math id="M384" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">53</mml:mn></mml:mrow></mml:math></inline-formula>)
from this study resulted in a slight improvement in the slope to <inline-formula><mml:math id="M385" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.17</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula>, with an intercept of <inline-formula><mml:math id="M386" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M387" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M388" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M389" display="inline"><mml:mn mathvariant="normal">0.88</mml:mn></mml:math></inline-formula> (Table 5).</p>
      <p id="d1e6466">Previous studies have reported PTR-MS values for formaldehyde that were systematically higher than DNPH–HPLC measurements (Wisthaler
et al., 2008; Cui et al., 2016) and higher than differential optical absorption spectroscopy (DOAS) and
Hantzsch techniques (Wisthaler et al., 2008; Warneke et al., 2011). Other
studies report DNPH–HPLC values for formaldehyde that were systematically lower than those reported by other analytical methods (DOAS,
FTIR, Hantzsch, TDLAS) (Kleindienst et al., 1988; Lawson et al., 1990; Gilpin et al., 1997; Hak et al., 2005; Wisthaler et al., 2006).</p>
      <p id="d1e6469">In summary, a comparison between the measurements of formaldehyde by PTR-MS and the DNPH technique indicates there was not
a significant difference in the measured concentrations although some discrepancy between the two instruments remains unresolved.</p>
</sec>
<sec id="Ch1.S3.SS2.SSS2">
  <label>3.2.2</label><title>Acetaldehyde</title>
      <p id="d1e6480">In measurements of the atmosphere the signal at <inline-formula><mml:math id="M390" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 in PTR-MS spectra is commonly attributed to protonated acetaldehyde (de Gouw
and Warneke, 2007). The comparisons between PTR-MS measurements at <inline-formula><mml:math id="M391" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 and DNPH measurements of acetaldehyde presented in Table 4
indicate a significant difference at the 95 % confidence limit between the mean values measured by each instrument. RMA
regression analysis between the PTR-MS data for <inline-formula><mml:math id="M392" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 and the acetaldehyde values determined from the DNPH–HPLC samples yielded
a slope of <inline-formula><mml:math id="M393" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.47</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.09</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M394" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.14</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M395" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>, an <inline-formula><mml:math id="M396" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M397" display="inline"><mml:mn mathvariant="normal">0.72</mml:mn></mml:math></inline-formula> and an
RMSD of <inline-formula><mml:math id="M398" display="inline"><mml:mn mathvariant="normal">0.11</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M399" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M400" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">77</mml:mn></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e6597">To examine any possible effect of liquid water, the analysis was repeated excluding the data of 16–24 April (see Sect. 3.2.1).
The results were a slope of <inline-formula><mml:math id="M401" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.43</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M402" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.08</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M403" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>, an <inline-formula><mml:math id="M404" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of  <inline-formula><mml:math id="M405" display="inline"><mml:mn mathvariant="normal">0.92</mml:mn></mml:math></inline-formula> and an RMSD of
<inline-formula><mml:math id="M406" display="inline"><mml:mn mathvariant="normal">0.05</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M407" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M408" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">54</mml:mn></mml:mrow></mml:math></inline-formula>) (Fig. 1g, Table 5). The results indicate an insignificant effect on slope but a substantial increase in the correlation coefficient and
reduction in RMSD by excluding the data indicating liquid water. The comparisons presented in Table 4 indicate a significant difference
at the 95 % confidence limit between the mean values measured by each instrument.</p>
      <p id="d1e6678">A positive bias in PTR-MS measurements of acetaldehyde may result from contributions to the <inline-formula><mml:math id="M409" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 signal from compounds other than
acetaldehyde.  Due to structural constraints the signal at <inline-formula><mml:math id="M410" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 can be either <inline-formula><mml:math id="M411" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> ions, <inline-formula><mml:math id="M412" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">HCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
and/or <inline-formula><mml:math id="M413" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">NO</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. The contribution from protonated carbon dioxide (<inline-formula><mml:math id="M414" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">HCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>) is not relevant here as it
is removed by the background zero correction.</p>
      <p id="d1e6769">Two studies using high-resolution PTR-ToF-MS have observed a single peak at <inline-formula><mml:math id="M415" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 consisting of <inline-formula><mml:math id="M416" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (Park et al.,
2013; Warneke et al., 2015). The <inline-formula><mml:math id="M417" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> product ions may result from protonated acetaldehyde; protonated vinyl
alcohol; protonated ethylene oxide; or fragment ions from ethylene glycol (Wood et al., 2015), ethanol, (Inomata and Tanimoto, 2009), 2-propanol
(Inomata and Tanimoto, 2010), methyl ethyl ketone, methyl glyoxal and methyl isobutyl ketone (Dunne, 2016). None of these compounds
were likely to be individually present in sufficient concentrations to account for the discrepancy observed in this study; however, the
combined effect of numerous compounds yielding <inline-formula><mml:math id="M418" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 product ions cannot be dismissed as a possible explanation.</p>
      <p id="d1e6839">In an atmospheric simulation chamber study three PTR-MS instruments reported acetaldehyde values close to the known injected
value, whereas a DNPH method significantly underestimated (<inline-formula><mml:math id="M419" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">30</mml:mn></mml:mrow></mml:math></inline-formula> %) the known chamber concentration (Apel et al., 2008). In a recent
comparison in urban air between PTR-MS and DNPH–HPLC, Cui et al. (2016) reported a slope of <inline-formula><mml:math id="M420" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> between the two methods but
a significant positive offset in the PTR-MS data of 0.83 <inline-formula><mml:math id="M421" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M422" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M423" display="inline"><mml:mn mathvariant="normal">0.56</mml:mn></mml:math></inline-formula>.</p>
      <p id="d1e6888">Herrington et al. (2007) reported the collection efficiency of acetaldehyde on DNPH cartridges declined from <inline-formula><mml:math id="M424" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula> % for
a sampling duration of 6 <inline-formula><mml:math id="M425" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M426" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">60</mml:mn></mml:mrow></mml:math></inline-formula> % for a sampling duration of 12 <inline-formula><mml:math id="M427" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula>, the reasons for which have not been
resolved. As 8 and 10 <inline-formula><mml:math id="M428" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula> sampling durations were used for the DNPH sampling in this study, poor collection efficiencies may have
resulted in a negative bias in the DNPH–HPLC measurements of acetaldehyde.</p>
      <p id="d1e6935">As shown in Fig. 2, other real-world inter-comparison studies have reported variable agreement between measurements of acetaldehyde by
PTR-MS and GC methods (slopes of 0.87–1.7, intercepts of <inline-formula><mml:math id="M429" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.25</mml:mn></mml:mrow></mml:math></inline-formula>–0.22, <inline-formula><mml:math id="M430" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of 0.38–0.86) (de Gouw et al., 2003; Warneke et al., 2011;
Kaser et al., 2013; Kajos et al., 2015).</p>
      <p id="d1e6959">In summary, a comparison between the measurements of acetaldehyde by PTR-MS at <inline-formula><mml:math id="M431" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45 and the DNPH technique indicates there was
a significant difference in the measured concentrations. There may be other species that
contribute to the PTR-MS signal at <inline-formula><mml:math id="M432" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 45, as well as under-reporting in the DNPH measurements. These processes are
poorly understood and poorly quantified measurement uncertainties.</p>
</sec>
<?pagebreak page155?><sec id="Ch1.S3.SS2.SSS3">
  <label>3.2.3</label><title>Acetone</title>
      <p id="d1e6994">In PTR-MS measurements, the ion signal at <inline-formula><mml:math id="M433" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 is regarded as a measure of protonated acetone. The comparisons between the PTR-MS
signal at <inline-formula><mml:math id="M434" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 and DNPH measurements of acetone presented in Table 4 indicate a significant difference at the 95 % confidence
limit between the mean values measured by each instrument.</p>
      <p id="d1e7021">The RMA regression analysis between the PTR-MS signal at <inline-formula><mml:math id="M435" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 and acetone measured in the DNPH samples for the whole dataset
yielded a slope of <inline-formula><mml:math id="M436" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.67</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of <inline-formula><mml:math id="M437" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.79</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M438" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M439" display="inline"><mml:mn mathvariant="normal">0.51</mml:mn></mml:math></inline-formula> (<inline-formula><mml:math id="M440" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">77</mml:mn></mml:mrow></mml:math></inline-formula>).
To examine any possible effect of liquid water, the analysis was repeated excluding the data of 16–24 April. The results yielded
a slope of <inline-formula><mml:math id="M441" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.01</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M442" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>, an
intercept of <inline-formula><mml:math id="M443" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.21</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M444" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>, an <inline-formula><mml:math id="M445" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of  <inline-formula><mml:math id="M446" display="inline"><mml:mn mathvariant="normal">0.76</mml:mn></mml:math></inline-formula> and an RMSD of <inline-formula><mml:math id="M447" display="inline"><mml:mn mathvariant="normal">0.24</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M448" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>
(<inline-formula><mml:math id="M449" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">53</mml:mn></mml:mrow></mml:math></inline-formula>) (Table 5, Fig. 1h) indicating a significant effect of liquid water.</p>
      <p id="d1e7177">As discussed previously the compartment housing the DNPH cartridges in the automated sampler was maintained at <inline-formula><mml:math id="M450" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M451" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C and
condensation of water from ambient air was observed in some of the chilled DNPH cartridges. As a result higher DNPH cartridge
extraction masses occurred at dew point temperatures <inline-formula><mml:math id="M452" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M453" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (Fig. 3e), and DNPH reported concentrations of acetone frequently
approached zero at dew point temperatures <inline-formula><mml:math id="M454" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">15</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M455" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (Fig. 3d).</p>
      <p id="d1e7238">Datapoints that coincided with average dew point temperatures <inline-formula><mml:math id="M456" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M457" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C were omitted from the RMA analysis. The average
dew point temperature was <inline-formula><mml:math id="M458" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M459" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C in only 12 out of 53 DNPH samples, resulting in a significantly reduced dataset. However,
omitting datapoints with dew point <inline-formula><mml:math id="M460" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M461" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C markedly improved the agreement between the DNPH and PTR-MS measurements of
acetone, with the results of the RMA analysis changing to a slope of <inline-formula><mml:math id="M462" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula>, an intercept of
<inline-formula><mml:math id="M463" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.22</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula> and an <inline-formula><mml:math id="M464" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of
<inline-formula><mml:math id="M465" display="inline"><mml:mn mathvariant="normal">0.89</mml:mn></mml:math></inline-formula> (<inline-formula><mml:math id="M466" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:math></inline-formula>) when water-affected samples were omitted.</p>
      <p id="d1e7354">Ho et al. (2014) also identified a significant negative bias in the collection efficiency of acetone on DNPH cartridges that was
related to humidity, sample flow rate and sample duration. While Ho et al. (2014) used a similar DNPH cartridge type, these authors
reported 35–80 % of acetone was lost under similar conditions as those experienced in this study (RH <inline-formula><mml:math id="M467" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">70</mml:mn></mml:mrow></mml:math></inline-formula> %, sample
flow 1 <inline-formula><mml:math id="M468" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, sample duration 8–10 <inline-formula><mml:math id="M469" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">h</mml:mi></mml:mrow></mml:math></inline-formula>). These authors proposed a plausible explanation for the observed
behaviour: when carbonyls pass through the DNPH sorbent, reactions occur involving the addition of the <inline-formula><mml:math id="M470" display="inline"><mml:mrow class="chem"><mml:mtext>-</mml:mtext><mml:msub><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> group to the
<inline-formula><mml:math id="M471" display="inline"><mml:mrow class="chem"><mml:mtext>-</mml:mtext><mml:mi mathvariant="normal">C</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> group to form a reaction intermediate. The reaction between DNPH and ketones occurs at a slower rate than for
aldehydes, resulting in poorer collection efficiencies for ketones. In the second step of the reaction, the intermediate loses a water
molecule to form the hydrazone derivative.  Therefore, when the water mixing ratio is high (i.e. high absolute humidity), loss via the
back reaction may be substantial.</p>
      <p id="d1e7419">In PTR-MS, the ion signal at <inline-formula><mml:math id="M472" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 is regarded as a measure of protonated acetone. However, in measurements of the
atmosphere the <inline-formula><mml:math id="M473" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 signal may also contain contributions from propanal and glyoxal (de Gouw and Warneke, 2007; Thalman et al., 2015; Stonner et al.,
2016).
Acetone, propanal and glyoxal were all measured by the DNPH method in the present study with mean values of <inline-formula><mml:math id="M474" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.74</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.54</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M475" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M476" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.06</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M477" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula> respectively (<inline-formula><mml:math id="M478" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">53</mml:mn></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e7503">Using the DNPH data for propanal and glyoxal, along with literature values of the PTR-MS response variables – branching ratios (Spanel
et al., 1997; Stonner et al., 2016) and reaction rates (Cappellin et al., 2012) – a correction was applied to the PTR-MS <inline-formula><mml:math id="M479" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 data
(excluding the data of 16–24 April, <inline-formula><mml:math id="M480" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">53</mml:mn></mml:mrow></mml:math></inline-formula>) to subtract interference in the measurement of acetone due to the presence of propanal and
glyoxal. This correction procedure is described in detail in the Supplement Sect. S.2.</p>
      <p id="d1e7530">Applying the correction for propanal and glyoxal interference to the reduced <inline-formula><mml:math id="M481" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 dataset (<inline-formula><mml:math id="M482" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">53</mml:mn></mml:mrow></mml:math></inline-formula>) from this study had
a negligible effect on the agreement between the two methods (<inline-formula><mml:math id="M483" display="inline"><mml:mrow><mml:mtext>slope</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.98</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula>, intercept <inline-formula><mml:math id="M484" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.19</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M485" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M486" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.76</mml:mn></mml:mrow></mml:math></inline-formula>). Similarly when this correction is applied to the <inline-formula><mml:math id="M487" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 data and compared with DNPH acetone for
periods with average dew point temperature <inline-formula><mml:math id="M488" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M489" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, only a minor improvement in the agreement between the two methods is observed
(<inline-formula><mml:math id="M490" display="inline"><mml:mrow><mml:mtext>slope</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.37</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M491" display="inline"><mml:mrow><mml:mtext>intercept</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.21</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M492" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e7683">Previous published atmospheric and chamber study measurements reported PTR-MS values for acetone that were <inline-formula><mml:math id="M493" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">30</mml:mn></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M494" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula> %
higher than simultaneous DNPH–HPLC measurements (Müller et al., 2006; Apel et al., 2008; Cui et al., 2016). Conversely, generally
good agreement has been observed between PTR-MS and GC methods and AP-CIMS (atmospheric pressure
chemical ionization mass spectrometry) (slopes <inline-formula><mml:math id="M495" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0.97–1.18, <inline-formula><mml:math id="M496" display="inline"><mml:mrow><mml:mtext>intercept</mml:mtext><mml:mo>=</mml:mo><mml:mo>-</mml:mo></mml:mrow></mml:math></inline-formula>0.28–0.06,
<inline-formula><mml:math id="M497" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.77</mml:mn></mml:mrow></mml:math></inline-formula>–0.96) (Fig. 3) (Sprung et al., 2001; de Gouw et al., 2003; Kaser et al., 2013; Wang et al., 2014; Kajos et al., 2015).</p>
      <p id="d1e7740">Overall, the PTR-MS signal at <inline-formula><mml:math id="M498" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 59 was dominated by acetone with minor contributions from propanal and glyoxal. Consistent with
previous studies, a significant negative bias was identified in sampling of acetone onto DNPH cartridges and further work is required
to determine the performance of DNPH cartridge sampling for quantitative measurements of acetone under real-world conditions. At high
humidity, the formation of condensation in DNPH cartridges must be guarded against as stated in TO-11A (USEPA, 1999b).</p>
</sec>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Discussion and conclusions</title>
      <p id="d1e7765">Comparisons have been made between measurements of benzene, toluene, <inline-formula><mml:math id="M499" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> aromatics and isoprene by two independent
techniques: PTR-MS and adsorbent tube sampling with GC-FID-MS analysis. Comparisons were also made between measurements of
formaldehyde, acetaldehyde and acetone by PTR-MS and DNPH derivatization with HPLC analysis during routine observations for an air
pollution field<?pagebreak page156?> campaign. In all seven comparisons the correlations between independent measurement techniques are high with <inline-formula><mml:math id="M500" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>
values of median 0.92, range 0.75 to 0.98, and the root mean square of the deviations of the observations from the regression line are
small with a median of 0.11, range 0.04 to 0.23 <inline-formula><mml:math id="M501" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula>, for the comparisons. This gives a high degree of confidence that for each
comparison the two independent techniques are responding to the same constituents.</p>
      <p id="d1e7798">The slope and intercept as determined by reduced major axis regression gives a different story. The slopes vary considerably with
a median of 1.25 and a range of 1.16–2.01. The intercepts vary with a median of 0.04 and a range of <inline-formula><mml:math id="M502" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.03 to 0.31 <inline-formula><mml:math id="M503" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula>. An ideal
comparison would give a slope of 1.00 and an intercept of 0. Also an analysis of the measurement uncertainties indicates significant
differences at the 95 % confidence limit between the mean concentrations for benzene, isoprene, acetaldehyde and acetone between
the different measurement techniques.</p>
      <p id="d1e7816">The reasons for the variations in slope include the contributions of non-target compounds to the measurement of the target compound for
benzene, toluene and isoprene by PTR-MS and the under-reporting of formaldehyde, acetaldehyde and acetone by the DNPH technique. This
study has identified specific issues with (a) the use of PTR-MS in urban areas at night when interferences from other compounds in
isoprene measurements are significant and (b) an interference of liquid water in the sample trap with acetone measurements by the DNPH
technique. Despite attempting to correct for these issues, significant discrepancies between the PTR-MS and the AT-VOC and DNPH–HPLC
methods remain unresolved. The PTR-MS always has a larger response than the AT-VOC and DNPH–HPLC method and the slopes reported here
were often at the higher end when compared with other published inter-comparison studies for the same compounds (Fig. 3). Additional,
unquantified uncertainty due to mass interference in PTR-MS and interference in the collection of efficiency of aldehydes and ketones
on DNPH may be responsible for the unresolved discrepancies reported here.</p>
      <p id="d1e7819">Other sources of uncertainty that may arise when comparing two observational datasets that are not included in the bottom-up
uncertainty analyses and were not assessed here include the following:
<list list-type="bullet"><list-item>
      <p id="d1e7824"><italic>Non-equivalent certified standards.</italic> As a first approach, an assumption of equivalence between certified gaseous standards, such
as those used to calibrate the PTR-MS and GC-FID-MS, and certified liquid standards used for the DNPH method is reasonable. The
equivalence of the certified liquid standards used to determine the instrument response for the DNPH method and the certified gaseous
standards used to calibrate the PTR-MS was not assessed in this study and may appear as a systematic bias in the top-down uncertainty
assessment.</p></list-item><list-item>
      <p id="d1e7830"><italic>Non-equivalent sampling and averaging times.</italic> While the averaging periods of the three measurement systems examined here overlapped
by 90 % or more, some uncertainty remains due to non-equivalent sampling times that is not incorporated into the bottom-up
uncertainty analysis.</p></list-item><list-item>
      <p id="d1e7836"><italic>Non-equivalent instrument calibration methods.</italic> The PTR-MS calibrations were performed daily in the field and the standard gases
were presented to the detector in a VOC-free ambient air matrix, whereas the AT-VOC and DNPH methods have calibration methods where
the standard is presented to the HPLC and GC-FID-MS in the laboratory, omitting field sampling influences.</p></list-item></list>
These are generic issues that should be addressed in future VOC inter-comparison studies.</p>
      <p id="d1e7843">The relationships reported for Sydney 2012 were incorporated into a larger analysis with 61 other inter-comparison studies for the same
compounds (found in the recent scientific literature; see Fig. 3). For the whole available set of inter-comparisons, the <inline-formula><mml:math id="M504" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> has
a median of 0.85 and a range of 0.13 to 0.98, the slopes had a median of 1.02 and a range of 0.58 to 2.01, and the intercept
has a median of 0.02 and a range of <inline-formula><mml:math id="M505" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.44 to 1.88. Based on this compilation we conclude that for the light aromatics, isoprene and the <inline-formula><mml:math id="M506" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math id="M507" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
carbonyls, the uncertainty in a set of atmospheric measurements with current measurement technology varies by a factor between 1.5 and
2. These uncertainties from the inter-comparisons (<inline-formula><mml:math id="M508" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">50</mml:mn></mml:mrow></mml:math></inline-formula> %) are significantly higher than uncertainties estimated using
standard propagation of error methods presented in Table 4 of 22 % or less. The difference is presumably the result of poorly
understood or neglected processes that affect these measurements and their uncertainties.</p>
      <p id="d1e7896">There are two qualifications concerning this overall uncertainty analysis.  This analysis in no way indicates what the uncertainty is
in measurements of other VOC compounds. A smaller uncertainty has been reported for alkanes (Hoerger et al., 2015). Similarly, if the
emissions and concentrations of a VOC are measured with the same technique or with techniques that are compared, then the
uncertainties associated with an atmospheric mass balance compiled using these measurements may be smaller than the case where
different VOC measurement techniques that have not been compared are used.</p>
      <p id="d1e7899">The uncertainties in VOC measurements identified here should be considered when assessing the reliability of VOC measurements from
individual instruments, when utilizing VOC data to constrain and inform air quality and climate models, when using VOC observations for
human exposure studies and when comparing ambient VOC data with satellite retrievals.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e7907">The Sydney Particle Study (SPS) involved a comprehensive
suite of measurements of atmospheric gases and aerosols in order to
characterize the sources, size distribution and composition of aerosols in
Sydney and better understand the<?pagebreak page157?> characteristics of gas-phase secondary
aerosol precursors. The dataset was published by Keywood et al. (2016) and
the final report was provided by Cope et al. (2014).</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e7910">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-11-141-2018-supplement" xlink:title="pdf">https://doi.org/10.5194/amt-11-141-2018-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e7919">The authors declare that they have no conflict of
interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e7925">The NSW Environmental Trust has provided support for this study through the “Atmospheric Particles in Sydney: model-observation
verification study”.  The NSW Office of Environment and Heritage supported the Sydney Particle Study. We also thank the staff and
management of Westmead Hospital for assistance during the field campaigns. This work was initiated when E. Dunne was undertaking her PhD
studies at Monash University. E. Dunne thanks Monash University for a postgraduate scholarship.<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>
Edited by: Yoshiteru Iinuma<?xmltex \hack{\newline}?>
Reviewed by: three anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Ambrose, J. L., Haase, K., Russo, R. S., Zhou, Y., White, M. L., Frinak, E. K., Jordan, C., Mayne, H. R., Talbot, R., and
Sive, B. C.: A comparison of GC-FID and PTR-MS toluene measurements in ambient air under conditions of enhanced monoterpene loading,
Atmos. Meas. Tech., 3, 959–980, <ext-link xlink:href="https://doi.org/10.5194/amt-3-959-2010" ext-link-type="DOI">10.5194/amt-3-959-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Apel, E., Brauers, T., Koppmann, R., Bandowe, B., Boßmeyer, J., Holzke, C., Tillmann, R., Wahner, R., Wegener, R.,
Brunner, A., Jocher, M., Ruuskanen, T., Spirig, C., Steigner, D., Steinbrecher, R., Gomez Alvarez, E., Müller, K.,
Burrows, J. P., Schade, G. W., Solomon, J., Ladstätter-Weißenmayer, A., Simmonds, P., Young, D.,
Hopkins, J. R., Lewis, A. C., Legreid, G., Reimann, S., Hansel, A., Wisthaler, A., Blake, R. S., Ellis, A. M., Monks, P. S., and
Wyche, K. P.: Intercomparison of oxygenated volatile organic compound measurements at the SAPHIR atmosphere simulation
chamber, J. Geophys. Res., 113,  D20307, <ext-link xlink:href="https://doi.org/10.1029/2008JD009865" ext-link-type="DOI">10.1029/2008JD009865</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation> Ayers, G. P.: Comment on regression analysis of air quality data, Atmos. Environ., 35, 2423–2425, 2001.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Cappellin, L., Karl, T., Probst, M., Ismailova, O., Winkler, P. M., Soukoulis, C., Aprea, E., Mark, T. D., Gasperi, F., and
Biasioli, F.: On quantitative determination of volatile organic compound concentrations using proton trasnfer reaction time-of-flight
mass spectrometry, Environ. Sci. Technol., 46, 2283–2290, <ext-link xlink:href="https://doi.org/10.1021/es203985t" ext-link-type="DOI">10.1021/es203985t</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>Christian, T. J., Kleiss, B., Yokelson, R. J., Holzinger, R., Crutzen, P. J., Hao, W. M., Shirai, T., and Blake, D. R.:
Comprehensive laboratory measurements of biomass burning emissions: 2. First intercomparion of open-path FTIR, PTR-MS, and
GC-MS/FID/ECD, J. Geophys. Res.-Atmos., 109, D02311, <ext-link xlink:href="https://doi.org/10.1029/2003JD003874" ext-link-type="DOI">10.1029/2003JD003874</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation> Cope, M., Keywood, M., Emmerson, K., Galbally, I. E., Boast, K., Chambers, S., Cheng, M., Crumeyrolle, S., Dunne, E.,
Fedele, R., Gillett, R., Griffiths, A., Harnwell, J., Katzfey, J., Hess, D., Lawson, S. L., Miljevic, B., Molloy, S., Powell, J.,
Reisen, F., Ristovski, Z., Ward, J., Zhang, C., and Zeng, J.: Sydney Particle Study – Stage II, CSIRO and Office of Environment and
Heritage, Australia, 2014.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Cui, L., Zhang, Z., Huang, Y., Lee, S. C., Blake, D. R., Ho, K. F., Wang, B., Gao, Y., Wang, X. M., and Louie, P. K. K.:
Measuring OVOCs and VOCs by PTR-MS in an urban roadside microenvironment of Hong Kong: relative humidity and temperature dependence,
and field intercomparisons, Atmos. Meas. Tech., 9, 5763–5779, <ext-link xlink:href="https://doi.org/10.5194/amt-9-5763-2016" ext-link-type="DOI">10.5194/amt-9-5763-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>de Gouw, J., Goldan, P. D., Warneke, C., Kuster, W. C., Roberts, J. M., Marchewka, M., Bertman, S. B., Pszenny, A. A. P.,
and Keene, W. C.: Validation of proton transfer reaction-mass spectrometry (PTR-MS) measurements of gas-phase organic compounds in
the atmosphere during the New England Air Quality Study (NEAQS) in 2002, J. Geophys. Res.-Atmos., 108, 4682, <ext-link xlink:href="https://doi.org/10.1029/2003JD003863" ext-link-type="DOI">10.1029/2003JD003863</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation> de Gouw, J. and Warneke, C.: Measurements of volatile organic compounds in the Earth's atmosphere using
proton-transfer-reaction mass spectrometry, Mass Spectrom. Rev., 26, 223–257, 2007.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation> Dunne, E.: Measurement of Atmospheric Volatile Organic Compounds with Proton Transfer Reaction-Mass Spectrometry,
PhD. Sci., Monash University, Melbourne, Australia, 280 pp., 2016.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>Dunne, E., Galbally, I. E., Lawson, S. L., and Patti, A.: Interference in the PTR-MS measurement of acetonitrile at <inline-formula><mml:math id="M509" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula>
42 in polluted urban air – a study uding switchable reagent ion PTR-MS, Int. J. Mass Spectrom., 319–320, 40–47, 2012.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation> Ellis, A. M. and Mayhew, C. A.: Proton Transfer Reaction Mass Spectrometry: Principles and Applications, John Wiley and
Sons Ltd., Chichester, UK, 2014.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation> Franq, B. G. and Govaerts, B. B.: Measurement methods comparison with errors-in-variables regressions. From horizintal to
vertical OLS regression, review and new perspectives, Chemometr. Intell. Lab., 134, 123–129, 2014.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation> Geron, C., Rasmussen, R., Arnts, R. R., and Guenther, A.: A review and synthesis of monoterpene speciation from forests in
the United States, Atmos. Environ., 34, 1761–1781, 2000.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>Gilpin, T., Apel, E., A., F., Wert, B., Calvert, J., Genfa, Z., Dasgupta, P. K., Harder, P., Heikes, P. W., Hopkins, B.,
Westberg, H., Kleindienst, T. E., Lee, Y. N., Zhou, X., Lonneman, W., and Sewell, S.: Intercomparion of six ambient [<inline-formula><mml:math id="M510" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>]
measurement techniques, J. Geophys. Res.-Atmos., 102, 21161–21188, <ext-link xlink:href="https://doi.org/10.1029/97JD01314" ext-link-type="DOI">10.1029/97JD01314</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation> Gueneron, M., Erickson, M. H., VanderSchelden, G. S., and Jobson, B. T.: PTR-MS fragmentation patterns of gasoline
hydrocarbons, Int. J. Mass Spectrom., 379, 97–109, 2015.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>Hak, C., Pundt, I., Trick, S., Kern, C., Platt, U., Dommen, J., Ordóñez, C., Prévôt, A. S. H., Junkermann,
W., Astorga-Lloréns, C., Larsen, B. R., Mellqvist, J., Strandberg, A., Yu, Y., Galle, B., Kleffmann, J., Lörzer, J. C.,
Braathen, G. O., and Volkamer, R.: Intercomparison of four different in-situ techniques for ambient formaldehyde measurements in
urban air, Atmos. Chem. Phys., 5, 2881–2900, <ext-link xlink:href="https://doi.org/10.5194/acp-5-2881-2005" ext-link-type="DOI">10.5194/acp-5-2881-2005</ext-link>, 2005.</mixed-citation></ref>
      <?pagebreak page158?><ref id="bib1.bib18"><label>18</label><mixed-citation>Hansel, A., Wisthaler, A., Schwarzman, M., and Lindinger, W.: Energy dependencies of the proton transfer reactions
<inline-formula><mml:math id="M511" display="inline"><mml:mrow><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>⇔</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">OH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula>, Int. J. Mass Spectrom., 167–268, 697–703, 1997.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation> Harris, D. C.: Quantitative Chemical Analysis, W. H. Freeman and Co, New York, 2003.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation> Herrington, J. S., Fan, Z. H., Lioy, P. J., and Zhang, J.: Low acetaldehyde collection efficiencies for 24 h sampling
with 2,4-dinitrophenylhydrazine(DNPH)-coated solid sorbents, Environ. Sci. Technol., 41, 580–585, 2007.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation> Ho, S. S. H., Chow, J. C., Watson, J. G., Ip, H. S. S., Ho, K. F., Dai, W. T., and Cao, J. J.: Biases in ketone
measurements using DNPH-coated solid sorbent cartridges, Anal. Chem., 6, 967–974, 2014.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>Hoerger, C. C., Claude, A., Plass-Duelmer, C., Reimann, S., Eckart, E., Steinbrecher, R., Aalto, J., Arduini, J.,
Bonnaire, N., Cape, J. N., Colomb, A., Connolly, R., Diskova, J., Dumitrean, P., Ehlers, C., Gros, V., Hakola, H., Hill, M., Hopkins,
J. R., Jäger, J., Junek, R., Kajos, M. K., Klemp, D., Leuchner, M., Lewis, A. C., Locoge, N., Maione, M., Martin, D., Michl, K.,
Nemitz, E., O'Doherty, S., Pérez Ballesta, P., Ruuskanen, T. M., Sauvage, S., Schmidbauer, N., Spain, T. G., Straube, E., Vana,
M., Vollmer, M. K., Wegener, R., and Wenger, A.: ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO
GAW and EMEP observation networks, Atmos. Meas. Tech., 8, 2715–2736, <ext-link xlink:href="https://doi.org/10.5194/amt-8-2715-2015" ext-link-type="DOI">10.5194/amt-8-2715-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation> Horwitz, W.: Evaluation of analytical methods used for regualtion of foods and drugs, Anal. Chem., 54, 67–76, 1982.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation> Inomata, S. and Tanimoto, H.: A deuterium-labeling study on the reproduction of hydronium ions in the PTR-MS detection of
ethanol, Int. J. Mass Spectrom., 285, 95–99, 2009.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation> Inomata, S. and Tanimoto, H.: A quantitative examination of the detection sensitvities of proton-transfer reaction mass
spectrometry for gaseous 2-propanol and acetic acid, B. Chem. Soc. Jpn., 83, 900–904, 2010.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>Inomata, S., Tanimoto, H., Kameyama, S., Tsunogai, U., Irie, H., Kanaya, Y., and Wang, Z.: Technical Note: Determination
of formaldehyde mixing ratios in air with PTR-MS: laboratory experiments and field measurements, Atmos. Chem. Phys., 8, 273–284,
<ext-link xlink:href="https://doi.org/10.5194/acp-8-273-2008" ext-link-type="DOI">10.5194/acp-8-273-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation> ISO: ISO 6879: 1995 Air Quality-Performance Characteristics and Related Concepts for Air Quality Measruing Methods,
International Organization for Standardization, Geneva, Switzerland, 1995.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation> JCGM: JCGM 100: 2008 Evaluation of Measurement Data – Guide to the Expression of Uncertainty in Measurement, BIPM,
Sevres, France, 2008.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>Jobson, B. T., Volkamer, R. A., Velasco, E., Allwine, G., Westberg, H., Lamb, B. K., Alexander, M. L., Berkowitz, C. M.,
and Molina, L. T.: Comparison of aromatic hydrocarbon measurements made by PTR-MS, DOAS and GC-FID during the MCMA 2003 Field
Experiment, Atmos. Chem. Phys., 10, 1989–2005, <ext-link xlink:href="https://doi.org/10.5194/acp-10-1989-2010" ext-link-type="DOI">10.5194/acp-10-1989-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>Kajos, M. K., Rantala, P., Hill, M., Hellén, H., Aalto, J., Patokoski, J., Taipale, R., Hoerger, C. C., Reimann, S.,
Ruuskanen, T. M., Rinne, J., and Petäjä, T.: Ambient measurements of aromatic and oxidized VOCs by PTR-MS and GC-MS:
intercomparison between four instruments in a boreal forest in Finland, Atmos. Meas. Tech., 8, 4453–4473,
<ext-link xlink:href="https://doi.org/10.5194/amt-8-4453-2015" ext-link-type="DOI">10.5194/amt-8-4453-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>Karl, T., Hansel, A., Cappellin, L., Kaser, L., Herdlinger-Blatt, I., and Jud, W.: Selective measurements of isoprene and
2-methyl-3-buten-2-ol based on NO<inline-formula><mml:math id="M512" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ionization mass spectrometry, Atmos. Chem. Phys., 12, 11877–11884,
<ext-link xlink:href="https://doi.org/10.5194/acp-12-11877-2012" ext-link-type="DOI">10.5194/acp-12-11877-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>Kaser, L., Karl, T., Schnitzhofer, R., Graus, M., Herdlinger-Blatt, I. S., DiGangi, J. P., Sive, B., Turnipseed, A.,
Hornbrook, R. S., Zheng, W., Flocke, F. M., Guenther, A., Keutsch, F. N., Apel, E., and Hansel, A.: Comparison of different real time
VOC measurement techniques in a ponderosa pine forest, Atmos. Chem. Phys., 13, 2893–2906, <ext-link xlink:href="https://doi.org/10.5194/acp-13-2893-2013" ext-link-type="DOI">10.5194/acp-13-2893-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation> Kato, S., Miyakawa, Y., Kaneko, T., and Kajii, Y.: Urban air measurements using PTR-MS in Tokyo area and comparison with
GC-FID measurements, Int. J. Mass Spectrom., 235, 103–110, 2004.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation> Kermack, K. and Haldane, J. B. S.: Organic correlation and allometry, Biometrika, 37, 30–41, 1950.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>Keywood, M., Selleck, P. W., Galbally, I. E., Lawson, S. J., Powell, J., Cheng, M., Gillett, R., Ward, J., Harnwell, J.,
Dunne, E., Boast, K., Reisen, F., Molloy, S., Griffiths, A., Chambers, S., Humphries, R., Andree-Guerette, E., and Cohen, D.: Sydney
Particle Study 2 – Aerosol and Gas Data Collection v1., CSIRO Data Collection, <ext-link xlink:href="https://doi.org/10.4225/08/5791B5528BD63" ext-link-type="DOI">10.4225/08/5791B5528BD63</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation> Kleindienst, T. E., Shepson, P. B., Nero, C. M., Arnts, R. R., Tejada, S. B., Mackay, G. I., Mayne, L. K., Schiff, H. I.,
Lind, J. A., Kok, A., Lazrus, A. L., Dasgupta, P. K., and Dong, S.: An intercomparison of formaldehyde measurement techniques at
ambient concentration, Atmos. Environ., 22, 1931–1939, 1988.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation> Kuster, W. C., Jobson, B. T., Karl, T., Riemer, D., Apel, E., Goldan, P. D., and Fehsenfeld, F. C.: Intercomparison of
volatile organic carbon measurement techniques and data at La Porte during the TexAQS2000 Air Quality Study, Environ. Sci. Technol.,
38, 221–228, 2004.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><mixed-citation> Lawson, D. R., Biermann, H. W., Tuazon, E. C., Winer, A. M., Mackay, G. I., Schiff, H. I., Kok, A., Dasgupta, P. K., and
Fung, K.: Formaldehyde measurement methods evaluation and ambient concentrations during the Carbonaceous Species Methods Comparison
Study, Aerosol Sci. Tech., 12, 64–76, 1990.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation> Lindinger, W., Hansel, A., and Jordan, A.: On-line monitoring of volatile organic compounds at pptv levels by means of
proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research, Int. J. Mass
Spectrom., 173, 191–241, 1998.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><mixed-citation> Maleknia, S., Bell, T., and Adams, M.: PTR-MS analysis of reference and plant-emitted volatile organic compounds,
Int. J. Mass Spectrom., 262, 203–210, 2007.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><mixed-citation> Müller, K., Haferkorn, S., Grabmer, W., Wistahler, A., Hansel, A., Kreuzwieser, J., Cojocariu, C., Rennenberg, H., and
Herrmann, H.: Biogenic carbonyl compounds within and above a coniferous forest in Germany, Atmos. Environ., 40, S81–S91, 2006.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><mixed-citation>
OEH: New south Wales Air Quality Statement 2015, Office of Environment and Heritage, Sydney NSW, Australia, 2015.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><mixed-citation> Park, J. H., Goldstein, A. H., Timkovsky, J., Fares, S., Weber, R. J., Karlik, J., and Holzinger, R.: Active
atmosphere-ecosystem<?pagebreak page159?> exchange of the vast majority of detected volatile organic compounds, Science, 341, 643–647, 2013.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><mixed-citation> Rogers, T. M., Grimsrud, E. P., Herndon, S. C., Jayne, J. T., Kolb, C. E., Allwine, E., Westberg, H., Lamb, B. K.,
Zavala, M., Molina, L. T., Molina, M. J., and Knighton, W. B.: On-road measurements of volatile organic compounds in the Mexico Cty
metropolitan area using proton transfer reaction mass spectrometry, Int. J. Mass Spectrom., 252, 26–37, 2006.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><mixed-citation>Spanel, P., Ji, Y., and Smith, D.: SIFT studies of the reactions of <inline-formula><mml:math id="M513" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, N<inline-formula><mml:math id="M514" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mrow><mml:mo>+</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M515" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> with a series of aldehydes and ketones, Int. J. Mass Spectrom., 165–166, 25–37, 1997.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><mixed-citation>Sprung, D., Jost, C., Reiner, T., Hansel, A., and Wistahler, A.: Acetone and acetonitrile in the tropical Indian Ocean
boundary layer and free troposphere: Aircraft-based intercomparison of AP-CIMS and PTR-MS measurements, J. Geophys. Res.-Atmos., 106,
28511–28527, <ext-link xlink:href="https://doi.org/10.1029/2000JD900599" ext-link-type="DOI">10.1029/2000JD900599</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><mixed-citation> Stonner, C., Derstroff, B., Klupfel, T., Crowley, J. N., and Williams, J.: Glyoxal measurement with proton transfer
reaction time of flight mass spectrometer (PTR-TOF-MS): characterization and calibration, J. Mass Spectrom., 52, 30–35,
2016.</mixed-citation></ref>
      <ref id="bib1.bib48"><label>48</label><mixed-citation>Thalman, R., Baeza-Romero, M. T., Ball, S. M., Borrás, E., Daniels, M. J. S., Goodall, I. C. A., Henry, S. B., Karl,
T., Keutsch, F. N., Kim, S., Mak, J., Monks, P. S., Muñoz, A., Orlando, J., Peppe, S., Rickard, A. R., Ródenas, M.,
Sánchez, P., Seco, R., Su, L., Tyndall, G., Vázquez, M., Vera, T., Waxman, E., and Volkamer, R.: Instrument intercomparison
of glyoxal, methyl glyoxal and NO<inline-formula><mml:math id="M516" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> under simulated atmospheric conditions, Atmos. Meas. Tech., 8, 1835–1862,
<ext-link xlink:href="https://doi.org/10.5194/amt-8-1835-2015" ext-link-type="DOI">10.5194/amt-8-1835-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><mixed-citation> USEPA: Compendium Method TO-17 Determination of Volatile Organic Compounds in Ambient Air Using Actie Sampling Onto
Sorbent Tubes, 1999a.</mixed-citation></ref>
      <ref id="bib1.bib50"><label>50</label><mixed-citation> USEPA: Compendium Method TO 11A- Determination of Formaldehyde in Ambient Air Using Adsorbent Cartridge Followed by High
Performance Liquid Chromatography (HPLC) [Active Sampling Methodology],
1999b.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><mixed-citation>Wang, M., Zeng, L., Lu, S., Shao, M., Liu, X., Yu, X., Chen, W., Yuan, Q., Hu, M., and Zhang, Z.: Development and
validation of a cryogen-free automatic gas chromatogrph system (GC-MS/FID) for online measurements of volatile organic compounds,
Anal. Methods-UK, 6, 9424, <ext-link xlink:href="https://doi.org/OI: 10.1039/c4ay01855a" ext-link-type="DOI">OI: 10.1039/c4ay01855a</ext-link>, 2014.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib52"><label>52</label><mixed-citation>Wang, T., Španěl, P., and Smith, D.: A selected ion flow tube, SIFT, study of the reactions of <inline-formula><mml:math id="M517" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math id="M518" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">NO</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M519" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> ions with several N- and O-containing heterocyclic compounds in support of SIFT-MS, Int. J. Mass
Spectrom., 237, 167–174, 2004.</mixed-citation></ref>
      <ref id="bib1.bib53"><label>53</label><mixed-citation> Warneke, C., van der Veen, C., Luxembourg, S., de Gouw, J., and Kok, A.: Measurements of benzene and toluene in ambient
air using proton-transfer-reaction mass spectrometry: calibration, humidity dependence, and field intercomparison, Int. J. Mass
Spectrom., 207, 167–182, 2001.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><mixed-citation> Warneke, C., de Gouw, J., Kuster, W. C., Goldan, P. D., and Fall, R.: Validation of atmospheric VOC measurements by
proton-transfer-reaction mass spectrometry using a gas-chromatographic preseparation method, Environ. Sci. Technol., 37, 2494–2501,
2003.</mixed-citation></ref>
      <ref id="bib1.bib55"><label>55</label><mixed-citation> Warneke, C., Roberts, J. M., Veres, P., Gilman, J., Kuster, W. C., Burling, I., Yokelson, R. J., and de Gouw, J.: VOC
identification and inter-comparison from laboratory biomass burning using PTR-MS and PIT-MS, Int. J. Mass Spectrom., 303, 6–14,
2011.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><mixed-citation> Wisthaler, A., Hansel, A., Koppmann, R., Brauers, T., Bossmeyer, J., Steinbrecher, R., Junkermann, W.,
Müller, K., Solomon, S. J., and Apel, E.: PTR-MS measurements of HCHO and results from HCHO intercomparison
measurements in the atmosphere simulation chamber SAPHIR, Geophys. Res. Abstr., 8, 04776, 2006.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><mixed-citation> Wood, E. C., Knighton, W. B., Fortner, E. C., Herndon, S. C., Onasch, T. B., Franklin, J. P., Worsnop, D. R.,
Dallmann, T. R., Gentner, D. R., Goldstein, A. H., and Harley, R. A.: Ethylene glycol emissions from on-road vehicles,
Environ. Sci. Technol., 49, 3322–3329, 2015.</mixed-citation></ref>
      <ref id="bib1.bib58"><label>58</label><mixed-citation> Yuan, B., Warneke, C., Shao, M., and De Gouw, J.: Interpretation of volatile organic compound measurements by
proton-transfer-reaction mass spectrometry over the deepwater horizon oil spill, Int. J. Mass Spectrom., 358, 43–48, 2014.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Comparison of VOC measurements made by PTR-MS, adsorbent tubes–GC-FID-MS and DNPH derivatization–HPLC during the Sydney Particle Study, 2012: a contribution to the assessment of uncertainty in routine atmospheric VOC measurements</article-title-html>
<abstract-html><p>Understanding uncertainty is essential for utilizing atmospheric volatile organic compound
(VOC) measurements in robust ways to develop atmospheric science. This study
describes an inter-comparison of the VOC data, and the derived uncertainty
estimates, measured with three independent techniques (PTR-MS,
proton-transfer-reaction mass spectrometry; GC-FID-MS,
gas chromatography with flame-ionization and mass spectrometric detection;
and DNPH–HPLC, 2,4-dinitrophenylhydrazine derivatization followed by analysis by high-performance
liquid chromatography)
during routine monitoring as part of the Sydney Particle Study (SPS) campaign in 2012. Benzene, toluene, C<sub>8</sub> aromatics, isoprene,
formaldehyde and acetaldehyde were selected for the comparison, based on
objective selection criteria from the available data. Bottom-up uncertainty
analyses were undertaken for each compound and each measurement system.
Top-down uncertainties were quantified via the inter-comparisons. In all
seven comparisons, the correlations between independent measurement
techniques were high with <i>R</i><sup>2</sup> values with a median of 0.92 (range 0.75–0.98)
and small root mean square of the deviations (RMSD) of the observations from the regression
line with a median of 0.11 (range 0.04–0.23&thinsp;ppbv). These results
give a high degree of confidence that for each comparison the response of the
two independent techniques is dominated by the same constituents. The slope
and intercept as determined by reduced major axis (RMA) regression gives
a different story. The slopes varied considerably with a median of 1.25 and
a range of 1.16–2.01. The intercepts varied with a median of 0.04 and a range
of −0.03 to 0.31&thinsp;ppbv. An ideal comparison would give a slope of 1.00
and an intercept of 0.</p><p>Some sources of uncertainty that are poorly quantified by the bottom-up uncertainty analysis method were identified, including:
contributions of non-target compounds to the measurement of the target compound for benzene, toluene and isoprene by PTR-MS as well as the
under-reporting of formaldehyde, acetaldehyde and acetone by the DNPH technique. As well as these, this study has identified a specific
interference of liquid water with acetone measurements by the DNPH technique.</p><p>These relationships reported for Sydney 2012 were incorporated into a larger analysis with 61 similar published inter-comparison
studies for the same compounds. Overall, for the light aromatics, isoprene and the C<sub>1</sub>–C<sub>3</sub> carbonyls, the uncertainty
in a set of measurements varies by a factor of between 1.5 and 2. These uncertainties ( ∼ 50&thinsp;%) are significantly higher
than uncertainties estimated using standard propagation of error methods, which in this case were  ∼ 22&thinsp;% or less, and are
the result of the presence of poorly understood or neglected processes that affect the measurement and its uncertainty. The
uncertainties in VOC measurements identified here should be considered when assessing the reliability of VOC measurements from routine
monitoring with individual, stand-alone instruments; when utilizing VOC data to constrain and inform air quality and climate models;
when using VOC observations for human exposure studies; and for comparison with satellite retrievals.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation> Ambrose, J. L., Haase, K., Russo, R. S., Zhou, Y., White, M. L., Frinak, E. K., Jordan, C., Mayne, H. R., Talbot, R., and
Sive, B. C.: A comparison of GC-FID and PTR-MS toluene measurements in ambient air under conditions of enhanced monoterpene loading,
Atmos. Meas. Tech., 3, 959–980, <a href="https://doi.org/10.5194/amt-3-959-2010" target="_blank">https://doi.org/10.5194/amt-3-959-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation> Apel, E., Brauers, T., Koppmann, R., Bandowe, B., Boßmeyer, J., Holzke, C., Tillmann, R., Wahner, R., Wegener, R.,
Brunner, A., Jocher, M., Ruuskanen, T., Spirig, C., Steigner, D., Steinbrecher, R., Gomez Alvarez, E., Müller, K.,
Burrows, J. P., Schade, G. W., Solomon, J., Ladstätter-Weißenmayer, A., Simmonds, P., Young, D.,
Hopkins, J. R., Lewis, A. C., Legreid, G., Reimann, S., Hansel, A., Wisthaler, A., Blake, R. S., Ellis, A. M., Monks, P. S., and
Wyche, K. P.: Intercomparison of oxygenated volatile organic compound measurements at the SAPHIR atmosphere simulation
chamber, J. Geophys. Res., 113,  D20307, <a href="https://doi.org/10.1029/2008JD009865" target="_blank">https://doi.org/10.1029/2008JD009865</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation> Ayers, G. P.: Comment on regression analysis of air quality data, Atmos. Environ., 35, 2423–2425, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation> Cappellin, L., Karl, T., Probst, M., Ismailova, O., Winkler, P. M., Soukoulis, C., Aprea, E., Mark, T. D., Gasperi, F., and
Biasioli, F.: On quantitative determination of volatile organic compound concentrations using proton trasnfer reaction time-of-flight
mass spectrometry, Environ. Sci. Technol., 46, 2283–2290, <a href="https://doi.org/10.1021/es203985t" target="_blank">https://doi.org/10.1021/es203985t</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation> Christian, T. J., Kleiss, B., Yokelson, R. J., Holzinger, R., Crutzen, P. J., Hao, W. M., Shirai, T., and Blake, D. R.:
Comprehensive laboratory measurements of biomass burning emissions: 2. First intercomparion of open-path FTIR, PTR-MS, and
GC-MS/FID/ECD, J. Geophys. Res.-Atmos., 109, D02311, <a href="https://doi.org/10.1029/2003JD003874" target="_blank">https://doi.org/10.1029/2003JD003874</a>, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation> Cope, M., Keywood, M., Emmerson, K., Galbally, I. E., Boast, K., Chambers, S., Cheng, M., Crumeyrolle, S., Dunne, E.,
Fedele, R., Gillett, R., Griffiths, A., Harnwell, J., Katzfey, J., Hess, D., Lawson, S. L., Miljevic, B., Molloy, S., Powell, J.,
Reisen, F., Ristovski, Z., Ward, J., Zhang, C., and Zeng, J.: Sydney Particle Study – Stage II, CSIRO and Office of Environment and
Heritage, Australia, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation> Cui, L., Zhang, Z., Huang, Y., Lee, S. C., Blake, D. R., Ho, K. F., Wang, B., Gao, Y., Wang, X. M., and Louie, P. K. K.:
Measuring OVOCs and VOCs by PTR-MS in an urban roadside microenvironment of Hong Kong: relative humidity and temperature dependence,
and field intercomparisons, Atmos. Meas. Tech., 9, 5763–5779, <a href="https://doi.org/10.5194/amt-9-5763-2016" target="_blank">https://doi.org/10.5194/amt-9-5763-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation> de Gouw, J., Goldan, P. D., Warneke, C., Kuster, W. C., Roberts, J. M., Marchewka, M., Bertman, S. B., Pszenny, A. A. P.,
and Keene, W. C.: Validation of proton transfer reaction-mass spectrometry (PTR-MS) measurements of gas-phase organic compounds in
the atmosphere during the New England Air Quality Study (NEAQS) in 2002, J. Geophys. Res.-Atmos., 108, 4682, <a href="https://doi.org/10.1029/2003JD003863" target="_blank">https://doi.org/10.1029/2003JD003863</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation> de Gouw, J. and Warneke, C.: Measurements of volatile organic compounds in the Earth's atmosphere using
proton-transfer-reaction mass spectrometry, Mass Spectrom. Rev., 26, 223–257, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation> Dunne, E.: Measurement of Atmospheric Volatile Organic Compounds with Proton Transfer Reaction-Mass Spectrometry,
PhD. Sci., Monash University, Melbourne, Australia, 280 pp., 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation> Dunne, E., Galbally, I. E., Lawson, S. L., and Patti, A.: Interference in the PTR-MS measurement of acetonitrile at <i>m</i>∕<i>z</i>
42 in polluted urban air – a study uding switchable reagent ion PTR-MS, Int. J. Mass Spectrom., 319–320, 40–47, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation> Ellis, A. M. and Mayhew, C. A.: Proton Transfer Reaction Mass Spectrometry: Principles and Applications, John Wiley and
Sons Ltd., Chichester, UK, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation> Franq, B. G. and Govaerts, B. B.: Measurement methods comparison with errors-in-variables regressions. From horizintal to
vertical OLS regression, review and new perspectives, Chemometr. Intell. Lab., 134, 123–129, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation> Geron, C., Rasmussen, R., Arnts, R. R., and Guenther, A.: A review and synthesis of monoterpene speciation from forests in
the United States, Atmos. Environ., 34, 1761–1781, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation> Gilpin, T., Apel, E., A., F., Wert, B., Calvert, J., Genfa, Z., Dasgupta, P. K., Harder, P., Heikes, P. W., Hopkins, B.,
Westberg, H., Kleindienst, T. E., Lee, Y. N., Zhou, X., Lonneman, W., and Sewell, S.: Intercomparion of six ambient [CH<sub>2</sub>O]
measurement techniques, J. Geophys. Res.-Atmos., 102, 21161–21188, <a href="https://doi.org/10.1029/97JD01314" target="_blank">https://doi.org/10.1029/97JD01314</a>, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation> Gueneron, M., Erickson, M. H., VanderSchelden, G. S., and Jobson, B. T.: PTR-MS fragmentation patterns of gasoline
hydrocarbons, Int. J. Mass Spectrom., 379, 97–109, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation> Hak, C., Pundt, I., Trick, S., Kern, C., Platt, U., Dommen, J., Ordóñez, C., Prévôt, A. S. H., Junkermann,
W., Astorga-Lloréns, C., Larsen, B. R., Mellqvist, J., Strandberg, A., Yu, Y., Galle, B., Kleffmann, J., Lörzer, J. C.,
Braathen, G. O., and Volkamer, R.: Intercomparison of four different in-situ techniques for ambient formaldehyde measurements in
urban air, Atmos. Chem. Phys., 5, 2881–2900, <a href="https://doi.org/10.5194/acp-5-2881-2005" target="_blank">https://doi.org/10.5194/acp-5-2881-2005</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation> Hansel, A., Wisthaler, A., Schwarzman, M., and Lindinger, W.: Energy dependencies of the proton transfer reactions
H<sub>3</sub>O<sup>+</sup> + CH<sub>2</sub>O ⇔ CH<sub>2</sub>OH<sup>+</sup> + H<sub>2</sub>O, Int. J. Mass Spectrom., 167–268, 697–703, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation> Harris, D. C.: Quantitative Chemical Analysis, W. H. Freeman and Co, New York, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation> Herrington, J. S., Fan, Z. H., Lioy, P. J., and Zhang, J.: Low acetaldehyde collection efficiencies for 24&thinsp;h sampling
with 2,4-dinitrophenylhydrazine(DNPH)-coated solid sorbents, Environ. Sci. Technol., 41, 580–585, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation> Ho, S. S. H., Chow, J. C., Watson, J. G., Ip, H. S. S., Ho, K. F., Dai, W. T., and Cao, J. J.: Biases in ketone
measurements using DNPH-coated solid sorbent cartridges, Anal. Chem., 6, 967–974, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation> Hoerger, C. C., Claude, A., Plass-Duelmer, C., Reimann, S., Eckart, E., Steinbrecher, R., Aalto, J., Arduini, J.,
Bonnaire, N., Cape, J. N., Colomb, A., Connolly, R., Diskova, J., Dumitrean, P., Ehlers, C., Gros, V., Hakola, H., Hill, M., Hopkins,
J. R., Jäger, J., Junek, R., Kajos, M. K., Klemp, D., Leuchner, M., Lewis, A. C., Locoge, N., Maione, M., Martin, D., Michl, K.,
Nemitz, E., O'Doherty, S., Pérez Ballesta, P., Ruuskanen, T. M., Sauvage, S., Schmidbauer, N., Spain, T. G., Straube, E., Vana,
M., Vollmer, M. K., Wegener, R., and Wenger, A.: ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO
GAW and EMEP observation networks, Atmos. Meas. Tech., 8, 2715–2736, <a href="https://doi.org/10.5194/amt-8-2715-2015" target="_blank">https://doi.org/10.5194/amt-8-2715-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation> Horwitz, W.: Evaluation of analytical methods used for regualtion of foods and drugs, Anal. Chem., 54, 67–76, 1982.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation> Inomata, S. and Tanimoto, H.: A deuterium-labeling study on the reproduction of hydronium ions in the PTR-MS detection of
ethanol, Int. J. Mass Spectrom., 285, 95–99, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation> Inomata, S. and Tanimoto, H.: A quantitative examination of the detection sensitvities of proton-transfer reaction mass
spectrometry for gaseous 2-propanol and acetic acid, B. Chem. Soc. Jpn., 83, 900–904, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation> Inomata, S., Tanimoto, H., Kameyama, S., Tsunogai, U., Irie, H., Kanaya, Y., and Wang, Z.: Technical Note: Determination
of formaldehyde mixing ratios in air with PTR-MS: laboratory experiments and field measurements, Atmos. Chem. Phys., 8, 273–284,
<a href="https://doi.org/10.5194/acp-8-273-2008" target="_blank">https://doi.org/10.5194/acp-8-273-2008</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation> ISO: ISO 6879: 1995 Air Quality-Performance Characteristics and Related Concepts for Air Quality Measruing Methods,
International Organization for Standardization, Geneva, Switzerland, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation> JCGM: JCGM 100: 2008 Evaluation of Measurement Data – Guide to the Expression of Uncertainty in Measurement, BIPM,
Sevres, France, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation> Jobson, B. T., Volkamer, R. A., Velasco, E., Allwine, G., Westberg, H., Lamb, B. K., Alexander, M. L., Berkowitz, C. M.,
and Molina, L. T.: Comparison of aromatic hydrocarbon measurements made by PTR-MS, DOAS and GC-FID during the MCMA 2003 Field
Experiment, Atmos. Chem. Phys., 10, 1989–2005, <a href="https://doi.org/10.5194/acp-10-1989-2010" target="_blank">https://doi.org/10.5194/acp-10-1989-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation> Kajos, M. K., Rantala, P., Hill, M., Hellén, H., Aalto, J., Patokoski, J., Taipale, R., Hoerger, C. C., Reimann, S.,
Ruuskanen, T. M., Rinne, J., and Petäjä, T.: Ambient measurements of aromatic and oxidized VOCs by PTR-MS and GC-MS:
intercomparison between four instruments in a boreal forest in Finland, Atmos. Meas. Tech., 8, 4453–4473,
<a href="https://doi.org/10.5194/amt-8-4453-2015" target="_blank">https://doi.org/10.5194/amt-8-4453-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation> Karl, T., Hansel, A., Cappellin, L., Kaser, L., Herdlinger-Blatt, I., and Jud, W.: Selective measurements of isoprene and
2-methyl-3-buten-2-ol based on NO<sup>+</sup> ionization mass spectrometry, Atmos. Chem. Phys., 12, 11877–11884,
<a href="https://doi.org/10.5194/acp-12-11877-2012" target="_blank">https://doi.org/10.5194/acp-12-11877-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation> Kaser, L., Karl, T., Schnitzhofer, R., Graus, M., Herdlinger-Blatt, I. S., DiGangi, J. P., Sive, B., Turnipseed, A.,
Hornbrook, R. S., Zheng, W., Flocke, F. M., Guenther, A., Keutsch, F. N., Apel, E., and Hansel, A.: Comparison of different real time
VOC measurement techniques in a ponderosa pine forest, Atmos. Chem. Phys., 13, 2893–2906, <a href="https://doi.org/10.5194/acp-13-2893-2013" target="_blank">https://doi.org/10.5194/acp-13-2893-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation> Kato, S., Miyakawa, Y., Kaneko, T., and Kajii, Y.: Urban air measurements using PTR-MS in Tokyo area and comparison with
GC-FID measurements, Int. J. Mass Spectrom., 235, 103–110, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation> Kermack, K. and Haldane, J. B. S.: Organic correlation and allometry, Biometrika, 37, 30–41, 1950.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation> Keywood, M., Selleck, P. W., Galbally, I. E., Lawson, S. J., Powell, J., Cheng, M., Gillett, R., Ward, J., Harnwell, J.,
Dunne, E., Boast, K., Reisen, F., Molloy, S., Griffiths, A., Chambers, S., Humphries, R., Andree-Guerette, E., and Cohen, D.: Sydney
Particle Study 2 – Aerosol and Gas Data Collection v1., CSIRO Data Collection, <a href="https://doi.org/10.4225/08/5791B5528BD63" target="_blank">https://doi.org/10.4225/08/5791B5528BD63</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation> Kleindienst, T. E., Shepson, P. B., Nero, C. M., Arnts, R. R., Tejada, S. B., Mackay, G. I., Mayne, L. K., Schiff, H. I.,
Lind, J. A., Kok, A., Lazrus, A. L., Dasgupta, P. K., and Dong, S.: An intercomparison of formaldehyde measurement techniques at
ambient concentration, Atmos. Environ., 22, 1931–1939, 1988.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation> Kuster, W. C., Jobson, B. T., Karl, T., Riemer, D., Apel, E., Goldan, P. D., and Fehsenfeld, F. C.: Intercomparison of
volatile organic carbon measurement techniques and data at La Porte during the TexAQS2000 Air Quality Study, Environ. Sci. Technol.,
38, 221–228, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation> Lawson, D. R., Biermann, H. W., Tuazon, E. C., Winer, A. M., Mackay, G. I., Schiff, H. I., Kok, A., Dasgupta, P. K., and
Fung, K.: Formaldehyde measurement methods evaluation and ambient concentrations during the Carbonaceous Species Methods Comparison
Study, Aerosol Sci. Tech., 12, 64–76, 1990.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation> Lindinger, W., Hansel, A., and Jordan, A.: On-line monitoring of volatile organic compounds at pptv levels by means of
proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research, Int. J. Mass
Spectrom., 173, 191–241, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation> Maleknia, S., Bell, T., and Adams, M.: PTR-MS analysis of reference and plant-emitted volatile organic compounds,
Int. J. Mass Spectrom., 262, 203–210, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation> Müller, K., Haferkorn, S., Grabmer, W., Wistahler, A., Hansel, A., Kreuzwieser, J., Cojocariu, C., Rennenberg, H., and
Herrmann, H.: Biogenic carbonyl compounds within and above a coniferous forest in Germany, Atmos. Environ., 40, S81–S91, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
OEH: New south Wales Air Quality Statement 2015, Office of Environment and Heritage, Sydney NSW, Australia, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation> Park, J. H., Goldstein, A. H., Timkovsky, J., Fares, S., Weber, R. J., Karlik, J., and Holzinger, R.: Active
atmosphere-ecosystem exchange of the vast majority of detected volatile organic compounds, Science, 341, 643–647, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation> Rogers, T. M., Grimsrud, E. P., Herndon, S. C., Jayne, J. T., Kolb, C. E., Allwine, E., Westberg, H., Lamb, B. K.,
Zavala, M., Molina, L. T., Molina, M. J., and Knighton, W. B.: On-road measurements of volatile organic compounds in the Mexico Cty
metropolitan area using proton transfer reaction mass spectrometry, Int. J. Mass Spectrom., 252, 26–37, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation> Spanel, P., Ji, Y., and Smith, D.: SIFT studies of the reactions of H<sub>3</sub>O<sup>+</sup>, NO<sup>+ </sup> and
O<sub>2</sub><sup>+</sup> with a series of aldehydes and ketones, Int. J. Mass Spectrom., 165–166, 25–37, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation> Sprung, D., Jost, C., Reiner, T., Hansel, A., and Wistahler, A.: Acetone and acetonitrile in the tropical Indian Ocean
boundary layer and free troposphere: Aircraft-based intercomparison of AP-CIMS and PTR-MS measurements, J. Geophys. Res.-Atmos., 106,
28511–28527, <a href="https://doi.org/10.1029/2000JD900599" target="_blank">https://doi.org/10.1029/2000JD900599</a>, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation> Stonner, C., Derstroff, B., Klupfel, T., Crowley, J. N., and Williams, J.: Glyoxal measurement with proton transfer
reaction time of flight mass spectrometer (PTR-TOF-MS): characterization and calibration, J. Mass Spectrom., 52, 30–35,
2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation> Thalman, R., Baeza-Romero, M. T., Ball, S. M., Borrás, E., Daniels, M. J. S., Goodall, I. C. A., Henry, S. B., Karl,
T., Keutsch, F. N., Kim, S., Mak, J., Monks, P. S., Muñoz, A., Orlando, J., Peppe, S., Rickard, A. R., Ródenas, M.,
Sánchez, P., Seco, R., Su, L., Tyndall, G., Vázquez, M., Vera, T., Waxman, E., and Volkamer, R.: Instrument intercomparison
of glyoxal, methyl glyoxal and NO<sub>2</sub> under simulated atmospheric conditions, Atmos. Meas. Tech., 8, 1835–1862,
<a href="https://doi.org/10.5194/amt-8-1835-2015" target="_blank">https://doi.org/10.5194/amt-8-1835-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation> USEPA: Compendium Method TO-17 Determination of Volatile Organic Compounds in Ambient Air Using Actie Sampling Onto
Sorbent Tubes, 1999a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation> USEPA: Compendium Method TO 11A- Determination of Formaldehyde in Ambient Air Using Adsorbent Cartridge Followed by High
Performance Liquid Chromatography (HPLC) [Active Sampling Methodology],
1999b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation> Wang, M., Zeng, L., Lu, S., Shao, M., Liu, X., Yu, X., Chen, W., Yuan, Q., Hu, M., and Zhang, Z.: Development and
validation of a cryogen-free automatic gas chromatogrph system (GC-MS/FID) for online measurements of volatile organic compounds,
Anal. Methods-UK, 6, 9424, <a href="https://doi.org/OI: 10.1039/c4ay01855a" target="_blank">https://doi.org/OI: 10.1039/c4ay01855a</a>, 2014.

</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation> Wang, T., Španěl, P., and Smith, D.: A selected ion flow tube, SIFT, study of the reactions of H<sub>3</sub>O<sup>+</sup>,
NO<sup>+</sup> and O<sub>2</sub><sup>+</sup> ions with several N- and O-containing heterocyclic compounds in support of SIFT-MS, Int. J. Mass
Spectrom., 237, 167–174, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation> Warneke, C., van der Veen, C., Luxembourg, S., de Gouw, J., and Kok, A.: Measurements of benzene and toluene in ambient
air using proton-transfer-reaction mass spectrometry: calibration, humidity dependence, and field intercomparison, Int. J. Mass
Spectrom., 207, 167–182, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation> Warneke, C., de Gouw, J., Kuster, W. C., Goldan, P. D., and Fall, R.: Validation of atmospheric VOC measurements by
proton-transfer-reaction mass spectrometry using a gas-chromatographic preseparation method, Environ. Sci. Technol., 37, 2494–2501,
2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation> Warneke, C., Roberts, J. M., Veres, P., Gilman, J., Kuster, W. C., Burling, I., Yokelson, R. J., and de Gouw, J.: VOC
identification and inter-comparison from laboratory biomass burning using PTR-MS and PIT-MS, Int. J. Mass Spectrom., 303, 6–14,
2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation> Wisthaler, A., Hansel, A., Koppmann, R., Brauers, T., Bossmeyer, J., Steinbrecher, R., Junkermann, W.,
Müller, K., Solomon, S. J., and Apel, E.: PTR-MS measurements of HCHO and results from HCHO intercomparison
measurements in the atmosphere simulation chamber SAPHIR, Geophys. Res. Abstr., 8, 04776, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation> Wood, E. C., Knighton, W. B., Fortner, E. C., Herndon, S. C., Onasch, T. B., Franklin, J. P., Worsnop, D. R.,
Dallmann, T. R., Gentner, D. R., Goldstein, A. H., and Harley, R. A.: Ethylene glycol emissions from on-road vehicles,
Environ. Sci. Technol., 49, 3322–3329, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>58</label><mixed-citation> Yuan, B., Warneke, C., Shao, M., and De Gouw, J.: Interpretation of volatile organic compound measurements by
proton-transfer-reaction mass spectrometry over the deepwater horizon oil spill, Int. J. Mass Spectrom., 358, 43–48, 2014.
</mixed-citation></ref-html>--></article>