<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-11-2821-2018</article-id><title-group><article-title>Folded tubular photometer for atmospheric measurements<?xmltex \hack{\break}?> of <inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO</article-title><alt-title>Folded tubular photometer for atmospheric measurements of
<inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO</alt-title>
      </title-group><?xmltex \runningtitle{Folded tubular photometer for atmospheric measurements of
{$\chem{NO_{{2}}}$} and NO}?><?xmltex \runningauthor{J.~W.~Birks et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Birks</surname><given-names>John W.</given-names></name>
          <email>johnb@twobtech.com</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Andersen</surname><given-names>Peter C.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Williford</surname><given-names>Craig J.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Turnipseed</surname><given-names>Andrew A.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Strunk</surname><given-names>Stanley E.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Ennis</surname><given-names>Christine A.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Mattson</surname><given-names>Erick</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>2B Technologies, Inc., 2100 Central Ave., Suite 105, Boulder, CO 80301,
USA</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Colorado Dept. of Public Health and Environment, Air Pollution Control
Division/Technical Services Program,<?xmltex \hack{\break}?> 4300 Cherry Creek Drive South, Denver,
CO 80246, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">John W. Birks (johnb@twobtech.com)</corresp></author-notes><pub-date><day>14</day><month>May</month><year>2018</year></pub-date>
      
      <volume>11</volume>
      <issue>5</issue>
      <fpage>2821</fpage><lpage>2835</lpage>
      <history>
        <date date-type="received"><day>22</day><month>January</month><year>2018</year></date>
           <date date-type="rev-request"><day>12</day><month>February</month><year>2018</year></date>
           <date date-type="rev-recd"><day>17</day><month>April</month><year>2018</year></date>
           <date date-type="accepted"><day>20</day><month>April</month><year>2018</year></date>
      </history>
      <permissions>
        
        
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018.html">This article is available from https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018.pdf</self-uri>
      <abstract>
    <p id="d1e167">We describe and characterize a modular folded tubular photometer
for making direct measurements of the concentrations of nitrogen dioxide
(NO<inline-formula><mml:math id="M3" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) and specify how this method could be extended to measure other
pollutants such as sulfur dioxide (SO<inline-formula><mml:math id="M4" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>), ozone (O<inline-formula><mml:math id="M5" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>), and black
carbon particulate matter. Direct absorbance measurements using this
photometer can be made across the spectral range from the ultraviolet (UV) to
the near infrared. The absorbance cell makes use of modular components
(tubular detection cells and mirror cubes) that allow construction of path
lengths of up to 2 m or more while maintaining low cell volumes. The long
path lengths and low cell volumes enable sensitive detection of ambient air
pollutants down to low part-per-billion levels for gas species and aerosol
extinctions down to 1 Mm<inline-formula><mml:math id="M6" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, corresponding to
<inline-formula><mml:math id="M7" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 0.1 <inline-formula><mml:math id="M8" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M9" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for black carbon particulates. Pressure
equalization throughout the stages of the absorbance measurement is shown to
be critical to accurate measurements of analyte concentrations. The present
paper describes the application of this photometer to direct measurements of
nitrogen dioxide (NO<inline-formula><mml:math id="M10" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) and the incorporation of design features that
also enable measurement of nitric oxide (NO) in the same instrument.
Excellent agreement for ambient measurements along an urban roadside was
found for both <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO measured by the folded tubular photometer
compared to existing standard techniques. Compared to commonly used methods
for measurements of NO<inline-formula><mml:math id="M12" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> species, the advantages of this approach include
(1) an absolute quantification for <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> based on the Beer–Lambert
law, thereby greatly reducing the frequency at which calibrations are
required; (2) the direct measurement of <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration without
prior conversion to NO as is required for the commonly used chemiluminescence
method; (3) the use of modular components that allow construction of
absorbance detection cells of varying lengths for extending the dynamic range
of concentrations that can be measured; (4) a more economical instrument than
other currently available direct measurement techniques for <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>;
and (5) the potential for simultaneous detection of additional species such
as <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and black carbon in the same instrument. In
contrast to other commercially available direct <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements,
such as cavity-attenuated phase-shift spectroscopy (CAPS), the folded tubular photometer also measures NO simultaneously in the same apparatus by
quantitatively converting NO to <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with ozone, which is then
detected by direct absorbance.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p id="d1e350">Poor air quality related to anthropogenic activity has been estimated to
contribute up to nearly 7 million premature deaths globally on an annual
basis (World Health Organization, 2014). Air pollutants such as ozone
(O<inline-formula><mml:math id="M20" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>), nitrogen dioxide (NO<inline-formula><mml:math id="M21" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>), sulfur dioxide (SO<inline-formula><mml:math id="M22" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>), and
particulate matter (PM) have been designated “criteria pollutants” in the
United States (US) because of their well-documented adverse health effects as
well as their ability to damage crops and natural ecosystems. Species such as
<inline-formula><mml:math id="M23" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and PM have significant impacts on Earth's radiation balance,
thus also impacting climate. Concentrations of these pollutants are<?pagebreak page2822?> routinely
measured both in ambient air and from direct industrial emissions (e.g.,
smokestack and fenceline monitoring). Limits on both pollutant emissions and
ambient concentrations are regulated by the US Environmental Protection
Agency (EPA). Concentrations of these pollutants are regulated by many other
countries as well. There are also non-regulated species that are known to
increase health risks and affect climate, such as black carbon particulates
(BC, a subset of PM). Pollutant species can be either produced directly by
various combustion processes (i.e., <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and BC) or
formed by secondary photochemistry from other precursor chemicals. For
example, it has been known since the 1950s that ozone is a secondary
pollutant formed in the interaction of sunlight with volatile organic
compounds and oxides of nitrogen (NO<inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> NO <inline-formula><mml:math id="M27" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M28" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) (Haagen-Smit
and Fox, 1954; Birks, 1998). Nitric oxide (NO) is also of great significance
since it is the principal precursor to <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and serves as a catalyst
in the atmosphere for formation of ozone. Therefore, it is expected that
measurements of <inline-formula><mml:math id="M30" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, NO, <inline-formula><mml:math id="M32" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and black
carbon will be required far into the future.</p>
      <p id="d1e487">It is critical to obtain reliable, long-term interference-free measurements
of these atmospheric pollutants, ideally with instruments that require little
maintenance and minimal need for re-calibration. Currently, a variety of
methods are used to monitor these different species, each having its own
advantages and problems. Many of the current methods need frequent
calibration or rely on indirect methods. For example, <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is most
commonly measured indirectly by conversion of <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> to NO, which is
then measured by chemiluminescence (Parrish and Fehsenfeld, 2000). Absorption
photometry is a direct measurement technique that is based on the intrinsic
absorption characteristics (wavelength-dependent absorption cross sections)
of the species of interest. Ozone, <inline-formula><mml:math id="M35" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and black
carbon all absorb at various wavelengths in the ultraviolet, visible, and/or
near infrared (IR). Light absorbance is governed by the Beer–Lambert law:
          <disp-formula id="Ch1.E1" content-type="numbered"><mml:math id="M37" display="block"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced open="[" close="]"><mml:mi>I</mml:mi></mml:mfenced></mml:mrow><mml:mrow><mml:mo>[</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub><mml:mo>]</mml:mo></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>l</mml:mi><mml:mi>c</mml:mi></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="1em"/><mml:mi mathvariant="normal">or</mml:mi><mml:mspace linebreak="nobreak" width="1em"/><mml:mi>c</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>l</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mi>ln⁡</mml:mi><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow><mml:mi>I</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
        where <inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the light intensity passing through the absorbance
cell with no analyte (e.g., <inline-formula><mml:math id="M39" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M40" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, black
carbon) present, <inline-formula><mml:math id="M42" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> is the intensity of light passing through the absorbance
cell when the analyte is present, <inline-formula><mml:math id="M43" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> is the extinction coefficient of
the analyte (absorption cross section in cm<inline-formula><mml:math id="M44" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M45" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for gases;
mass extinction coefficient in m<inline-formula><mml:math id="M46" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> g<inline-formula><mml:math id="M47" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for particulates), <inline-formula><mml:math id="M48" display="inline"><mml:mi>l</mml:mi></mml:math></inline-formula> is
the path length through the detection cell (cm or m), and <inline-formula><mml:math id="M49" display="inline"><mml:mi>c</mml:mi></mml:math></inline-formula> is the
concentration of analyte within the detection cell (molec cm<inline-formula><mml:math id="M50" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for
gases; <inline-formula><mml:math id="M51" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M52" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for particulates). Gas-phase concentrations are
typically converted to mixing ratios by measuring the temperature and
pressure within the absorbance cell and applying the ideal gas law. Light
absorbance is an especially attractive technique, since it relies only on
knowing <inline-formula><mml:math id="M53" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula>, which is an intrinsic property of the molecule in the case
of gas-phase species; the path length, which is easily measured; and the
ability to measure relative light intensities. Key to using absorption
photometry is understanding the limits to the analytical precision (relying
on the magnitude of <inline-formula><mml:math id="M54" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula>, the minimum detectable absorbance, and the
path length) and ensuring adequate selectivity over potential interferences
(by selection of analytical wavelength(s) not significantly absorbed by other
species and/or by selective scrubbing of the analyte).</p>
      <p id="d1e765">For ozone, the most common measurement method is by absorbance of the
253.7 nm line of a low-pressure mercury lamp. Here, co-absorbing
interferences are small due to the large <inline-formula><mml:math id="M55" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption cross
section (e.g., Turnipseed et al., 2017). Atmospheric measurements are easily
made because the required precision (low ppb) can be achieved with practical
path lengths (<inline-formula><mml:math id="M56" display="inline"><mml:mi>l</mml:mi></mml:math></inline-formula>, Eq. 1). The absorbance, ln<inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mi>I</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, can be
measured in modern photometers with a precision (standard deviation or root
mean square
noise) of typically <inline-formula><mml:math id="M58" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 3 <inline-formula><mml:math id="M59" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M60" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Combining this with the
absorption cross section and optical path length, Eq. (1) can be rearranged
to determine the overall precision expected for measurement of a given
analyte:
          <disp-formula id="Ch1.E2" content-type="numbered"><mml:math id="M61" display="block"><mml:mrow><mml:mi mathvariant="normal">Precision</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mfenced close=")" open="("><mml:mi mathvariant="normal">ppb</mml:mi></mml:mfenced><mml:mo>≅</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>×</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:mrow><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>l</mml:mi><mml:mo>(</mml:mo><mml:mi>P</mml:mi><mml:mo>/</mml:mo><mml:mi>k</mml:mi><mml:mi>T</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mfrac></mml:mstyle><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">9</mml:mn></mml:msup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
        Here, <inline-formula><mml:math id="M62" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M63" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> are the absorbance cell pressure and temperature,
respectively, and <inline-formula><mml:math id="M64" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> is the Boltzmann constant. For ozone, <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mn mathvariant="normal">253.7</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.15</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math id="M66" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M67" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Burkholder et al.,
2015) and the precision is calculated to be 0.7 ppb for a path length of
15 cm or 0.35 ppb for a path length of 30 cm. These are in good agreement
with the performance of commercially available ozone monitors.</p>
      <p id="d1e963">Pollutants such as <inline-formula><mml:math id="M68" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M69" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and black carbon absorb much
less strongly than ozone in the spectral region where stable light sources
exist (<inline-formula><mml:math id="M70" display="inline"><mml:mi mathvariant="italic">λ</mml:mi></mml:math></inline-formula> &gt; 250 nm), thus requiring much longer path
lengths. For <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, with an absorption cross section of
<inline-formula><mml:math id="M72" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 6 <inline-formula><mml:math id="M73" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M74" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">19</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M75" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M76" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at 405 nm (near the
peak of the <inline-formula><mml:math id="M77" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption spectrum; Burrows et al., 1998) and
assuming the same minimum measurable absorbance (3 <inline-formula><mml:math id="M78" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M79" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), a
path length of <inline-formula><mml:math id="M80" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 203 cm is required to obtain a precision of 1 ppb.
This is similar to that of <inline-formula><mml:math id="M81" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> if measured at 290 nm (<inline-formula><mml:math id="M82" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M83" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 7 <inline-formula><mml:math id="M84" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M85" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">19</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M86" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M87" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; Vandaele et al.,
1994). The mass extinction coefficient used for black carbon absorption at
880 nm is 7.7 m<inline-formula><mml:math id="M88" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> g<inline-formula><mml:math id="M89" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Drinovec et al., 2015). Using this value
and again assuming the precision in the measurement of absorbance to be
3 <inline-formula><mml:math id="M90" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M91" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, a path length of 3.9 m (390 cm) would be required
to obtain a precision of 0.1 <inline-formula><mml:math id="M92" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M93" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for black carbon mass
concentration.</p>
      <p id="d1e1219">Because of the long path lengths required, the pollutants <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math id="M95" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and black carbon are difficult to measure by direct absorbance
in the gas phase. Several approaches for long path absorption measurements of
species in the gas phase have been taken in the past. Open path systems have
used differential optical absorption spectroscopy (DOAS) with path lengths up
to many kilometers (Platt, 1994); however, this limits their use for
determining spatial distributions of pollutants. Furthermore, DOAS requires
the pollutants detected to<?pagebreak page2823?> have significant structure in the absorption
spectrum so that absorptions can be extracted via fitting algorithms.</p>
      <p id="d1e1244">Closed-path, in situ absorption photometers have typically relied on using
mirrors to “fold” the path length within the detection cell, with up to 100
or more reflections to increase the absorption path length. Of these, the
White cell (White, 1942) is the most common. However, even miniaturized
versions of White cells have relatively large volumes, typically
180 cm<inline-formula><mml:math id="M96" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> and larger, so that the flush times for typical flow rates of
1.8 L min<inline-formula><mml:math id="M97" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> are long. Also, the cell shapes required by the mirror
arrangements exacerbate the problem, requiring multiple flush times to
exchange 99 % of the cell contents (<inline-formula><mml:math id="M98" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 4.6 flush times assuming
exponential dilution). Thus, for a cell volume of 180 cm<inline-formula><mml:math id="M99" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> (volume of a
currently commercially available White cell with 2 m path length) and flow
rate of 1.8 L min<inline-formula><mml:math id="M100" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, the total required flush time is 27.6 s. To
obtain the low absorbance precisions of 3 <inline-formula><mml:math id="M101" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M102" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> stated
earlier, it is important to measure the reference light intensity
(<inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) every 5 to 10 s due to small intensity fluctuations in
typical light sources. This requires total cell flush times of 2.5 to 5 s
(to measure both <inline-formula><mml:math id="M104" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>), which is incompatible with White
cells unless excessively large (and hence impractical) flow rates are used
(&gt; 10 L min<inline-formula><mml:math id="M106" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). Other folded-path configurations can be
flushed more rapidly (e.g., Herriott cells; Herriott and Schulte, 1965) but
require a collimated light source, which is noisier compared to uncollimated
sources such as light-emitting diodes (LEDs) or low-pressure mercury lamps,
thus largely offsetting the advantage in sensitivity gained by the longer
path lengths.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><caption><p id="d1e1359">Schematic diagram of a folded tubular photometer for measuring the
concentrations of gas-phase species such as <inline-formula><mml:math id="M107" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M108" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and
<inline-formula><mml:math id="M109" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and particulates such as black carbon, based on the absorbance
of UV (<inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M111" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), visible (<inline-formula><mml:math id="M112" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, black carbon),
or infrared (black carbon) light.</p></caption>
        <?xmltex \igopts{width=398.338583pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f01.png"/>

      </fig>

      <p id="d1e1435">More recent advances employ high-reflectivity cavities to generate long path
lengths. Cavity-enhanced absorption spectroscopy (CEAS) and variants such as
cavity ring-down spectroscopy (CRDS) and cavity-attenuated phase-shift
(CAPS) spectroscopy have been successfully used to measure numerous
atmospheric constituents in the visible and IR regions (Paldus and
Kachanov, 2004; Crosson, 2008; Kebabian et al., 2005). However, these
high-reflectivity cavities are often expensive, and care must be taken such
that mirror reflectivity does not degrade over time (resulting in a changing
sensitivity and hence a need for frequent re-calibration). Furthermore, they
tend to operate over a fairly narrow wavelength range limited by the mirror
reflectivities of the cavity.</p>
      <p id="d1e1438">Here we describe a new approach, a folded tubular photometer, for
measurements of a pollutant or other species in a gas such as air. The use of
modular mirror cubes in combination with tubular flow cells allows the path
to be folded, making it compact enough for a several-meters-long detection
cell to fit into a conventional rack-mount-sized or smaller enclosure that
can be produced relatively inexpensively compared to other optical
techniques. Further, the design makes it possible to reduce the cell volume
and therefore also the flush times significantly, allowing a new <inline-formula><mml:math id="M113" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> or
<inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurement to be made once every 5 s or less. Because those
measurements are made close together in time, variations in the lamp
intensity between measurements is small, resulting in higher precision
relative to a White cell or Herriott cell of the same path length. Using this
approach, measurements of ambient concentrations of <inline-formula><mml:math id="M115" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math id="M116" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and black carbon by direct absorbance in the gas phase become
feasible and economical.</p>
      <p id="d1e1482">This paper presents a design of the folded tubular photometer that enables
rapid measurements of both <inline-formula><mml:math id="M117" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO within the same instrument
and temporally separated by only a few seconds. <inline-formula><mml:math id="M118" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is measured by
direct absorption at 405 nm. NO is measured by addition of ozone to convert
NO to <inline-formula><mml:math id="M119" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with nearly 100 % conversion by the reaction:
          <disp-formula id="Ch1.E3" content-type="numbered"><mml:math id="M120" display="block"><mml:mrow><mml:mrow class="chem"><mml:mi mathvariant="normal">NO</mml:mi></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>→</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p id="d1e1552">Subsequent measurement of the increase in <inline-formula><mml:math id="M121" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration upon
addition of ozone provides a highly accurate measurement of NO. The results
described here show that this method provides a viable approach for measuring
both <inline-formula><mml:math id="M122" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO at atmospheric levels. Alternative commercially
available methods for measuring <inline-formula><mml:math id="M123" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> based on direct absorbance
(CRDS or CAPS) currently measure <inline-formula><mml:math id="M124" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> but not NO. Therefore, the
folded tubular photometer described here provides a relatively inexpensive
alternative that measures both NO<inline-formula><mml:math id="M125" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> species required for air quality
compliance and predictive modeling. The folded tubular photometer design also
will be discussed as it pertains to direct absorbance measurements of other
atmospheric species such as <inline-formula><mml:math id="M126" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and BC.</p>
</sec>
<sec id="Ch1.S2">
  <title>Experimental </title>
<sec id="Ch1.S2.SS1">
  <title>Generalized folded tubular photometer </title>
      <?pagebreak page2824?><p id="d1e1631">Figure 1 is a generalized diagram of the folded tubular photometer for direct
measurements via the Beer–Lambert law (Eq. 1) of concentrations of gas-phase
molecules by absorption or total particle extinction (absorption and
scattering). An air pump draws sample air through the entire apparatus. For
gas-phase analytes, the sample air enters the instrument through an inert
Teflon particle filter, preventing particles in the sample air from
interfering with the absorbance measurements. The flow then passes through a
three-way reference valve, which directs the air either through a scrubber to
remove the analyte from the flowing stream (measuring <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) or
through a tube bypassing the scrubber (measuring <inline-formula><mml:math id="M128" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>). It is desirable that
this valve be switched as frequently as possible to minimize any effect of
drift of the lamp intensity between the measurements of <inline-formula><mml:math id="M129" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and
<inline-formula><mml:math id="M130" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. However, it is critical to completely flush the detection
cell between the <inline-formula><mml:math id="M131" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurements as well as allow for
adequate signal averaging time of the measured light intensity. This
requirement sets a limit on how frequently the reference valve can be
switched. For example, this valve is switched every 5 s for
measuring <inline-formula><mml:math id="M133" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for a cell volume of 37.4 cm<inline-formula><mml:math id="M134" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> (0.476 cm i.d.,
210 cm long) and flow rate of 1.8 L min<inline-formula><mml:math id="M135" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (30 cm<inline-formula><mml:math id="M136" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> s<inline-formula><mml:math id="M137" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)
achieved in our optical bench (described below). This allows for two complete
flushes of the cell volume within the initial 3 s followed by averaging of
the light intensity for the final 2 s.</p>
      <p id="d1e1742">Sample air next passes through one or more parallel tubes composed of
Nafion<sup>™</sup>. Nafion membranes selectively
transport water molecules across the tube wall and bring the humidity inside
the tube to approximately the same level as in the surrounding air. Wilson
and Birks (2006) first demonstrated for ozone monitors that small changes in
humidity during ozone-scrubbed (<inline-formula><mml:math id="M138" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>) and unscrubbed (<inline-formula><mml:math id="M139" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>)
measurements resulted in light transmission changes through the optical cell
due to adsorption of differing amounts of water vapor on the cell wall. They
further showed that use of a Nafion tube just prior to entering the detection
cell eliminated this water vapor interference by equilibrating humidity
between the <inline-formula><mml:math id="M140" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> cycles. Although Nafion can be used to dry
the sample (e.g., if the surrounding air has been dried), it is only
necessary to equilibrate the water vapor level with the surrounding air to
provide equal humidity during both measurement cycles. This has the advantage
of not altering the mixing ratio of an analyte by removal of atmospheric
water vapor. For the examples given here where the typical flow rate is
1.8 L min<inline-formula><mml:math id="M142" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, four 25 cm long, 1.07 mm i.d., 1.35 mm o.d. tubes of
Nafion (total of 1 m length) plumbed in parallel were found to effectively
remove any interference from rapid changes in relative humidity of sampled
air. Use of higher flow rates require proportionally larger internal surface
areas (longer Nafion tubes at constant i.d.) to prevent humidity
interferences. It should be noted that the use of Nafion tubing is not
required for particle measurements since the analyte scrubber can be a
hydrophobic particle filter of very low surface area, which absorbs or desorbs
very little water vapor. Also, Nafion tubing may cause losses of particles,
thereby biasing measurements.</p>
      <p id="d1e1797">The air flow next enters the optical bench, which is composed of one or more
tubular detection cells (six shown in Fig. 1) and an appropriate number of
mirror modules (five shown in Fig. 1), each containing two mirrors oriented
at 45<inline-formula><mml:math id="M143" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> to the flow path. The mirror modules allow sample air to flow
through them and to enter the subsequent detection cell. The mirrors direct
the light along the same path as the air flow (in either the same or opposite
direction – shown in Fig. 1 as counter to the air flow). The mirrors fold
the optical path so as to increase the path length and, thus, the sensitivity
of the measurement.</p>
      <p id="d1e1809">The light source module contains a light source that emits light of the
appropriate wavelength(s) to be selectively absorbed by the analyte of
interest. The preferred light source for most analytes is an LED, although other light sources may be used. LEDs are readily
available with emissions ranging from about 250 nm in the UV to about
1000 nm in the IR and have directional light emission that can easily
be coupled into the cell. We found LEDs with bandwidths of a few tens of
nanometers to be preferred over laser diodes. Although laser diodes are much
brighter, are highly collimated, and have a very narrow bandwidth, they
typically exhibit much lower stability (larger fluctuations in intensity on
timescales of a few seconds). In the application described here, an LED
with emission maximum at 405 nm was utilized to measure <inline-formula><mml:math id="M144" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.
Preliminary work in our lab (to be published) suggests that we can measure
black carbon using an LED with maximum emission near 880 nm. Multiple LEDs
may be combined, using either dichroic mirrors or fiber optics, and the LEDs
switched on and off to measure multiple species (e.g., <inline-formula><mml:math id="M145" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at 290
and <inline-formula><mml:math id="M146" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at 405 nm in the same air sample) or to characterize
aerosol light extinction over a large wavelength range to characterize
particulate composition.</p>
      <?pagebreak page2825?><p id="d1e1846">At the end of the optical bench, the light is detected by a photodiode.
Typically a large fraction of the light (&gt; 90 %) from the LED
source is lost to partial reflection at the cell walls and mirrors, and the
fraction of light arriving at the photodiode depends on a number of factors
such as the intensity and degree of collimation of the light source,
reflectivity of the cell walls and mirrors, humidity of the sample, and the
pressure inside the detection cell. These losses have no effect on the
measurement of the analyte concentration so long as they remain constant
during measurements of <inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (analyte scrubbed) and <inline-formula><mml:math id="M148" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> (analyte
present). However, these losses do place a limit on the overall path length
that is achievable at a given wavelength.</p>
      <p id="d1e1867">The concentration of the analyte (typically in units of molec cm<inline-formula><mml:math id="M149" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for
gases) is calculated from the Beer–Lambert law (Eq. 1) from the absorption
cross section averaged over the bandwidth of the light source; the path
length of the light beam, calculated from the dimensions of the optical
bench; and the electrical signals (current or voltage) of the photodiode,
which are proportional to <inline-formula><mml:math id="M150" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M151" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>. Since <inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M153" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> are not measured at exactly the same time (typically 5 s apart), one can
average the values of <inline-formula><mml:math id="M154" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measured before and after the
measurement of <inline-formula><mml:math id="M155" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> in order to increase the precision and accuracy of the
measurement. Temperature and pressure are measured within the detection cell
for the purpose of calculating a mixing ratio of the analyte in typical units
of ppm or ppb.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p id="d1e1939">Perspective drawing showing the various modular components of a
folded tubular photometer.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f02.png"/>

        </fig>

      <p id="d1e1948">The voltage sensitive orifice (VSO) valve of Fig. 1 serves a particularly
important role. It is used to admit air to the flowing stream after the
optical bench and prior to the air pump. Adding air at this point both
reduces the flow rate through the optical bench and increases the average
pressure. Because the analyte scrubber is more restrictive than the bypass,
the pressure within the detection cells is lower when the air is being drawn
through scrubber (<inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> being measured). To compensate, the VSO
valve is adjusted in a feedback loop to increase the cell pressure. The VSO
valve is adjusted to equalize the pressure of the sample air within the
optical bench during <inline-formula><mml:math id="M157" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M158" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurements to within an error
of 0.1 mbar. This eliminates a potentially large error resulting from the
effect of pressure on the transmission of light through the optical bench,
which is discussed in Sect. 3.1 below. The flow rate during the
<inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurement is also reduced, but only by <inline-formula><mml:math id="M160" display="inline"><mml:mo>≤</mml:mo></mml:math></inline-formula> 5 % and
does not significantly impact the degree of cell flushing. Pressure
adjustment is made during the first 2 s of the 5 s cycle, during which the
optical cell is also being flushed. The values of <inline-formula><mml:math id="M161" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are
measured in the final 2 s of the corresponding 5 s cycles after the
pressure adjustment is achieved and the cell has been thoroughly flushed.</p>

      <?xmltex \floatpos{p}?><fig id="Ch1.F3"><caption><p id="d1e2019">Schematic diagram showing the three-way valve states for measuring
<bold>(a)</bold> <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M164" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>; <bold>(b)</bold> <inline-formula><mml:math id="M165" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> for
<inline-formula><mml:math id="M166" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M167" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for NO; and <bold>(c)</bold> <inline-formula><mml:math id="M168" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> for NO. Flow
path is shown in red, green, and blue for panels <bold>(a)</bold>, <bold>(b)</bold>,
and <bold>(c)</bold>, respectively. Panel <bold>(d)</bold> depicts an idealized
measurement sequence corresponding to the three steps shown in panels
<bold>(a)</bold>–<bold>(c)</bold> and indicates the timing of the three measurement
stages.</p></caption>
          <?xmltex \igopts{width=213.395669pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f03.png"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS2">
  <title>Modular optical bench</title>
      <p id="d1e2121">A more detailed perspective drawing of the modular optical bench, as used in
the work described here, is shown in Fig. 2. Six tubular detection cells and
five mirror modules are shown, although other numbers of tubular detection cells
and mirror modules could be used. In this example, not all of the detection
cells are of the same length, so as to make room on the optical bench for
both the LED light source and the photodiode detector. Tubing connections for
the air inlet and air outlet are shown. The flow could be reversed with no
effect on the analyte measurement. Each mirror module contains two mirrors.
The optical bench constructed for use in the examples that follow made use of
Viton O-rings to seal the two ends of the tubular detection cells to the
mirror modules, LED module, and photodiode module. The mirror, light source,
and light detector modules are mounted to a vibrationally isolated, rigid
optical bench. The modular nature of the optical bench allows the path length
to be increased or decreased by adding or removing tubular cells and mirror
modules as desired for measurements of analytes in varying absorbance ranges.
Also, as shown in Fig. 2, tubular cells may be of different lengths, making a
wide range of path lengths possible. The materials used for construction of
the detection cells should be inert toward the analyte being measured, with
no significant loss of the analyte to exposed surfaces. The examples given
below made use of an optical bench constructed of aluminum. To increase
transmission of light, the interiors of the cell were polished using either a
cylinder hone or a metal bristle brush of the type used to clean gun barrels.</p>
      <p id="d1e2124">For the <inline-formula><mml:math id="M169" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> photometer discussed below, we used tubular cells with
<inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:math></inline-formula> in. (0.476 cm) i.d. such that a
2.1 m long absorption cell has a calculated volume of only
<inline-formula><mml:math id="M171" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 37.4 cm<inline-formula><mml:math id="M172" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>. Thus, the time for one flush at a flow rate of
1.8 L min<inline-formula><mml:math id="M173" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (30 cm<inline-formula><mml:math id="M174" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> s<inline-formula><mml:math id="M175" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) is only 1.25 s. Rapid
measurement of the light intensity from the photodiode (at <inline-formula><mml:math id="M176" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 16 Hz)
showed that &gt; 98 % of the analyte was removed in less than
1.5 s, confirming that only one or two flush times are required to achieve
complete flushing of the previous contents of the cell. This allows a new <inline-formula><mml:math id="M177" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>
or <inline-formula><mml:math id="M178" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurement to be made once every<?pagebreak page2826?> 5 s or less, thereby
reducing variations in the lamp intensity between measurements. As a result,
the precision achieved is higher than is possible in a White or Herriott cell
of the same path length.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <?xmltex \opttitle{Folded tubular photometer for measurements of
{$\protect\chem{NO_{{2}}}$} and NO}?><title>Folded tubular photometer for measurements of
<inline-formula><mml:math id="M179" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO</title>
      <p id="d1e2243">Figure 3 is a schematic diagram of the inlet system of a folded tubular photometer designed to measure both NO<inline-formula><mml:math id="M180" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and
NO using a LED light source with maximum emission at 405 nm.
<inline-formula><mml:math id="M181" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorbs at 405 nm with an absorption cross section of
<inline-formula><mml:math id="M182" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 6 <inline-formula><mml:math id="M183" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M184" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">19</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M185" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M186" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Burrows et al.,
1998). The 405 nm LED is of low enough power (<inline-formula><mml:math id="M187" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 4.3 mW) that
photodissociation of <inline-formula><mml:math id="M188" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is insignificant (&lt; 1 %,
assuming no loss of light in the optical cells and a dissociation quantum
yield of 0.37 at 405 nm; Burkholder et al., 2015). NO does not absorb at
this wavelength but can be quantitatively converted to <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. The
reference NO<inline-formula><mml:math id="M190" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> scrubber contains a combination of manganese dioxide to
oxidize NO to <inline-formula><mml:math id="M191" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> followed by activated carbon to remove
<inline-formula><mml:math id="M192" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M193" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 300 mg of each) The entire scrubber is heated to
110 <inline-formula><mml:math id="M194" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. We have found that <inline-formula><mml:math id="M195" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is removed quantitatively
with this scrubber up to at least 2 ppm. We have also observed no loss in
scrubbing efficiency over 24 h periods of exposure to <inline-formula><mml:math id="M196" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 300 ppb of
<inline-formula><mml:math id="M197" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, nor during longer-term urban ambient measurements (Allen et
al., 2018). The inlet system is the same as in Fig. 1 but with some additions
(shown in the gray box) that allow conversion of NO to <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> by the
highly selective reaction of NO with <inline-formula><mml:math id="M199" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Eq. 3). This is accomplished by adding a small flow
(&lt; 5 % of total instrument flow) of ozonized ambient air
(produced photolytically by a low-pressure mercury discharge lamp) and
allowing them to react within a reaction coil during a third measurement
step. The three measurements steps are shown in the panels of Fig. 3. In
Fig. 3a (air flow paths shown in red), <inline-formula><mml:math id="M200" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M201" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is
measured as the sample air passes through the NO<inline-formula><mml:math id="M202" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> scrubber, removing
both NO and <inline-formula><mml:math id="M203" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. In the shaded gray box, approximately
<inline-formula><mml:math id="M204" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 70 cm<inline-formula><mml:math id="M205" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> min<inline-formula><mml:math id="M206" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> of air, scrubbed of both ozone and NO<inline-formula><mml:math id="M207" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>,
bypasses the ozone generator and is added to the sample air stream.
Correction is made in the firmware for dilution of <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO in
the air sample by this small flow. The bypass valve then directs the combined
flow to bypass the reaction coil, pass through the Nafion humidity
equilibrator, and enter the optical bench.</p>
      <p id="d1e2534">Figure 3b (air flow paths shown in green) differs from Fig. 3a only in that
the state of the reference valve is changed so that sample air bypasses the
reference <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> scrubber. The <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> present in the sample
stream now attenuates light passing through the optical bench, and the light
intensity <inline-formula><mml:math id="M211" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> is measured for <inline-formula><mml:math id="M212" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Using the value of
<inline-formula><mml:math id="M213" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measured in configuration 3a and <inline-formula><mml:math id="M214" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> measured in
configuration 3b, the <inline-formula><mml:math id="M215" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration can now be calculated using
the Beer–Lambert law (Eq. 1). The light intensity measured using
configuration b also serves as the <inline-formula><mml:math id="M216" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for calculation of the NO
concentration.</p>
      <?pagebreak page2827?><p id="d1e2618">In Fig. 3c (air flow paths shown in blue), the states of both the ozone and
bypass valves are changed such that the small flow
(<inline-formula><mml:math id="M217" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 70 cm<inline-formula><mml:math id="M218" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> min<inline-formula><mml:math id="M219" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) passes through the photolytic ozone
generator, and the ozonized air mixes with the sample air and passes through
the reaction coil where NO reacts with ozone to form <inline-formula><mml:math id="M220" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. The ozone
mixing ratio in the combined streams (ozonized air mixed with sample air) is
typically 8 ppm. Light intensity in the ozone photolysis cell is
continuously measured by a photodiode and output in the data stream, and this
light intensity value can be used to infer that adequate ozone is present to
quantitatively consume NO. The reaction coil is constructed from a 1 m
coiled length of 0.635 cm i.d. PTFE, producing a reaction volume of
31.7 cm<inline-formula><mml:math id="M221" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> and residence time for a total flow rate of 1.8 L min<inline-formula><mml:math id="M222" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>
of 1.06 s. Based on the reaction rate coefficient of <inline-formula><mml:math id="M223" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 1.9 <inline-formula><mml:math id="M224" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M225" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">14</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M226" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M227" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> s<inline-formula><mml:math id="M228" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at 298 K
(Birks et al., 1976; Borders and Birks, 1982; Burkholder et al., 2015) and a
total pressure of 1 atm (1013.25 mbar), the reaction is calculated to be
97.6 % complete within the reaction coil. Nearly all of the remaining
2.4 % of NO is converted during transit through the optical bench.
Assuming pseudo-first-order kinetics, the average amount of converted NO
detected within the optical bench and measured is calculated to be
98.8 %. It should also be noted that the combined residence time within
both the reaction coil and the detection cells is <inline-formula><mml:math id="M229" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 2.2 s, which
allows for a complete flush of the detection volume prior to measuring the
light intensity.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><caption><p id="d1e2758">Plot of data obtained for two prototypes of the folded tubular
photometer showing the analyzer offset in ppb of <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> as a function
of the measured pressure difference (<inline-formula><mml:math id="M231" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>I</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math id="M232" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi>I</mml:mi><mml:mi>o</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>) between a sample
bypassing the NO<inline-formula><mml:math id="M233" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> scrubber (<inline-formula><mml:math id="M234" display="inline"><mml:mrow><mml:mi>I</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and a sample passing through the
NO<inline-formula><mml:math id="M235" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> scrubber (<inline-formula><mml:math id="M236" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>).</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f04.png"/>

        </fig>

      <p id="d1e2843">The light intensity measured using configuration c serves as the value of
<inline-formula><mml:math id="M237" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> in the calculation of NO using Eq. (1). For NO measurements, correction
for incomplete reaction may be made by dividing by the average of the
fraction of NO converted; i.e., 0.988 for the flow conditions described above.
In practice, air standards having known NO and <inline-formula><mml:math id="M238" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations
were used to calibrate the outputs of the instrument to correct for
incomplete reaction and any other factors affecting the sensitivity and
offset of the instrument.</p>
      <p id="d1e2864">To summarize (and shown schematically in Fig. 3d), by continuously cycling
between valve states a, b, and c every 5 s, a new value of either
NO or <inline-formula><mml:math id="M239" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> may be calculated and updated as follows: (a) a new
value of <inline-formula><mml:math id="M240" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M241" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is measured, allowing calculation
and updating of a new value of <inline-formula><mml:math id="M242" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration; (b) a new value
for both <inline-formula><mml:math id="M243" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>for <inline-formula><mml:math id="M244" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M245" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for NO are measured,
allowing calculation and updating of new values of <inline-formula><mml:math id="M246" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO; and
(c) a new value of <inline-formula><mml:math id="M247" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> for NO is measured, allowing calculation and updating
of a new value of NO. It should also be noted that if only <inline-formula><mml:math id="M248" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
measurements are desired, step (c) can be omitted (and the small flow that
delivers ozone discontinued). Conversely, step (a) can be omitted if only NO
measurements are desired.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <title>Effect of pressure on analyte measurements</title>
      <p id="d1e2982">A problem we encountered when attempting to use long tubular detection cells,
with the light beam either folded using mirrors or unfolded, is that the
transmission of light through the cell was found to be pressure dependent.
For example, the pressure difference resulting from flowing a sample gas
directly into the cell during the measurement of <inline-formula><mml:math id="M249" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> vs. flowing through the
solid-phase <inline-formula><mml:math id="M250" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> scrubber during the measurement of <inline-formula><mml:math id="M251" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>
at a flow rate of <inline-formula><mml:math id="M252" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1.8 L min<inline-formula><mml:math id="M253" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> was found typically to be
<inline-formula><mml:math id="M254" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 10 mbar. This pressure difference alone causes an unacceptable
offset error of typically <inline-formula><mml:math id="M255" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 50 ppb in the measurement of
<inline-formula><mml:math id="M256" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Although correction can be made for the offset, the offset may
change due to variations in the conductance of the scrubber, which varies
with environmental factors such as humidity, thereby introducing unacceptable
levels of low-frequency noise (drift).</p>
      <p id="d1e3059">Figure 4 illustrates the observed pressure variation during measurements of
<inline-formula><mml:math id="M257" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M258" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> on the measurement of <inline-formula><mml:math id="M259" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration. In
this plot, pressure difference is the pressure of the cell during the <inline-formula><mml:math id="M260" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>
measurement (Fig. 3b) minus the pressure in the cell during the
<inline-formula><mml:math id="M261" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> measurement (Fig. 3a). Since the scrubber adds to the
restriction, the pressure is typically lower during the <inline-formula><mml:math id="M262" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>
measurement. To enable adjustments of the pressure difference, a needle valve
was placed in line with the analyte scrubber or in line with the bypass and
the restriction was varied. Results are provided in Fig. 4 for two prototype
<inline-formula><mml:math id="M263" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> monitors constructed. The presence of unmatched pressures
during the <inline-formula><mml:math id="M264" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>and <inline-formula><mml:math id="M265" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> measurements was found to produce a false
reading, or offset, that is additive to the true <inline-formula><mml:math id="M266" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration.
As can be seen in Fig. 4, the offset varies linearly over the range tested
(<inline-formula><mml:math id="M267" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>P</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M268" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>13 mbar) and can be quite large, ranging from <inline-formula><mml:math id="M269" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>100
to <inline-formula><mml:math id="M270" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>150 ppb. The slopes of the regression lines for the two prototypes
differ, ranging from 5.0 to 12.5 ppb mbar<inline-formula><mml:math id="M271" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, and we found that such
slopes<?pagebreak page2828?> vary from instrument to instrument. As discussed below, we believe
that this offset is due to changes in the transmission of light through the
optical bench with change in pressure, most likely because of the effect of
pressure on the refractive index of the sample gas, but possibly due to other
factors.</p>
      <p id="d1e3211">The magnitude of the pressure dependence on light transmission is unexpected
and not easily explained by any existing theory. For example, it cannot be
accounted for by differences in Rayleigh scattering by air molecules at
different densities. The Rayleigh scattering cross section in air is
<inline-formula><mml:math id="M272" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M273" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">27</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M274" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M275" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at 532 nm. For a path length of
210 cm and temperature of 25 <inline-formula><mml:math id="M276" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, a 10 mbar pressure change would
cause an extinction change of only <inline-formula><mml:math id="M277" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 <inline-formula><mml:math id="M278" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M279" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, nearly 2
orders of magnitude below the limit of detection for our absorbance
measurements.</p>
      <p id="d1e3290">The effect is likely due to variations in the propagation of the
non-collimated beam of light through the cell by reflection from the cell's
internal surface and/or mirrors used to fold the path. This can cause slight
changes in the amount of light reaching and sensed by the detector. Light
propagation through the optical cell is highly sensitive to subtle changes in
both the optical alignment and path length (due to the multiple reflections)
and to the refractive indices of the sample gas (which depends on pressure)
and the cell wall or mirror surfaces. However, at present it is uncertain
which of these effects is responsible for the observed pressure dependencies.</p>
      <p id="d1e3294">The effect of pressure on absorbance measurements was made insignificant by
controlling the pressure during measurements of <inline-formula><mml:math id="M280" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M281" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> to be
identical to within 0.1 mbar, using the VSO valve shown in Fig. 1. This
degree of pressure control yields offsets in the range 0.5 to 1.25 ppb for
the two prototype instruments evaluated for pressure effects. Such small
offsets are easily removed by applying an additive offset calibration factor
determined while passing the sample air through a zeroing NO<inline-formula><mml:math id="M282" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> scrubber.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <?xmltex \opttitle{Analytical figures of merit for NO and NO${}_{{{2}}}$}?><title>Analytical figures of merit for NO and NO<inline-formula><mml:math id="M283" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula></title>
      <p id="d1e3339">The folded tubular photometer configured for measurements of <inline-formula><mml:math id="M284" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
and NO (Fig. 3) is now commercially available from 2B Technologies (Boulder,
CO) as the model 405 nm <inline-formula><mml:math id="M285" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M286" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO <inline-formula><mml:math id="M287" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M288" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>
Monitor<sup>™</sup>. It was externally tested and
approved as a Federal Equivalent Method (FEM) for monitoring of the criteria
pollutant <inline-formula><mml:math id="M289" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for compliance with the US Clean Air Act (designated
as EQNA-0217-243). During the period 1 April 2016 through 30 November 2017,
206 calibrations were performed on 41 different instruments. Calibration
curves were constructed at five concentrations (0, 50, 100, 150, and
200 ppb) for both <inline-formula><mml:math id="M290" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO. Standard concentrations of
<inline-formula><mml:math id="M291" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO were generated using a Teledyne-API model 700 Dynamic
Dilution Calibrator. An internal photolytic ozone source and photometer
generates known concentrations of ozone, which react with an excess of NO
supplied by a compressed gas cylinder to produce a stoichiometric increase in
<inline-formula><mml:math id="M292" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and decrease in NO concentration, according to Eq. (3) above.
The internal ozone photometer is traceable to NIST through a Thermo Electron
model 49i-PS Ozone Calibration Primary Standard. Typically, five independent
calibrations were carried out for each instrument and linear regressions
applied to each calibration curve. The instruments were found to be highly
linear over this concentration range with coefficients of determination
<inline-formula><mml:math id="M293" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> averaging 0.9995 and 0.9993 for <inline-formula><mml:math id="M294" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO, respectively,
for the 206 calibrations performed. Although typical calibrations only cover
the range of 0–200 ppb for ambient measurements, strict linearity up to
1000 ppb has been observed and the linear dynamic range is estimated to
extend to 10 000 ppb (10 ppm) for <inline-formula><mml:math id="M295" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and 2000 ppb (2 ppm) for
NO. The dynamic range for NO is limited by the ozone concentration
(<inline-formula><mml:math id="M296" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 8 ppm) used to convert NO to <inline-formula><mml:math id="M297" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><caption><p id="d1e3490">Analytical and physical specifications, 2B Technologies model
405 nm <inline-formula><mml:math id="M298" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M299" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO <inline-formula><mml:math id="M300" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M301" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> folded tubular photometer.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Linear dynamic range</oasis:entry>
         <oasis:entry colname="col2">0–10 000 ppb (0–10 ppm) for <inline-formula><mml:math id="M302" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>; 0–2000 ppb (0–2 ppm) for NO</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Measurement frequency</oasis:entry>
         <oasis:entry colname="col2">0.2 Hz (once every 5 s)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Resolution</oasis:entry>
         <oasis:entry colname="col2">0.1 ppb</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Accuracy</oasis:entry>
         <oasis:entry colname="col2">Greater of 2 ppb or 2 % of reading</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Precision (1<inline-formula><mml:math id="M303" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> rms noise)</oasis:entry>
         <oasis:entry colname="col2">&lt; 0.5 ppb (with conditional averaging filter),</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">&lt; 3 ppb (no conditional averaging filter)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Limit of detection (2<inline-formula><mml:math id="M304" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">&lt; 1 ppb (with conditional averaging filter)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Response time</oasis:entry>
         <oasis:entry colname="col2">10 s single mode (<inline-formula><mml:math id="M305" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> or NO measured)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">15 s dual mode (both <inline-formula><mml:math id="M306" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO measured)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">20 s (with conditional averaging filter)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Flow rate (nominal)</oasis:entry>
         <oasis:entry colname="col2">1.5 L min<inline-formula><mml:math id="M307" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Operating temperature</oasis:entry>
         <oasis:entry colname="col2">10 to 50 <inline-formula><mml:math id="M308" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (FEM approved for 20–30 <inline-formula><mml:math id="M309" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for NO<inline-formula><mml:math id="M310" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Power requirement</oasis:entry>
         <oasis:entry colname="col2">11–14 V dc or <inline-formula><mml:math id="M311" display="inline"><mml:mrow><mml:mn mathvariant="normal">120</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">240</mml:mn></mml:mrow></mml:math></inline-formula> V ac, 1.3 A at 12 V, 16 watt</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Size</oasis:entry>
         <oasis:entry colname="col2">Rackmount: 17<inline-formula><mml:math id="M312" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:math></inline-formula> <inline-formula><mml:math id="M313" display="inline"><mml:mi>w</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M314" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 14.5<inline-formula><mml:math id="M315" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:math></inline-formula> d <inline-formula><mml:math id="M316" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 5.5<inline-formula><mml:math id="M317" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:math></inline-formula> h (43 <inline-formula><mml:math id="M318" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 37 <inline-formula><mml:math id="M319" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 14 cm)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Weight</oasis:entry>
         <oasis:entry colname="col2">18.6 lb (8.4 kg)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e3844">Precisions (1<inline-formula><mml:math id="M320" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> obtained in dual mode (both <inline-formula><mml:math id="M321" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO
measured) for 5 s measurements were typically in the range 2–3 ppb with an
average of 2.3 ppb. When operating in single mode (only NO or NO<inline-formula><mml:math id="M322" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>), the
response time is 10 s, the time required to obtain a new measurement of both
<inline-formula><mml:math id="M323" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M324" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. In dual mode, the response time is increased to 15 s
(one of the measurement cycles simultaneously provides <inline-formula><mml:math id="M325" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> for <inline-formula><mml:math id="M326" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math id="M327" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for NO (Fig. 3), thus shortening the response time from
what would otherwise be 20 s). Averaging can be used to trade off response
time for improved precision. Ambient air monitors commonly employ a
conditional averaging filter for improving the signal-to-noise ratio of this
measurement. This consists of maintaining both a short-time running average
(<inline-formula><mml:math id="M328" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 20–30 s) and a long-time running average (<inline-formula><mml:math id="M329" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 2–5 min). When
measured concentrations are stable, the long-term average is output; however,
when rapid concentration changes occur, the short-term average is output.
This type of filtering has the advantage of providing improved precision
while maintaining the ability to respond relatively fast to large
concentration changes. The averaging times and threshold concentration
changes of the conditional averaging filter are user selectable in the model
405 nm monitor. For averaging times of 3 min, the precisions were found to
be independent of test concentration over the 0–200 ppb calibration range,
averaging 0.386 ppb for <inline-formula><mml:math id="M330" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and 0.381 ppb for NO for the
206 calibrations performed. Other specifications for the model 405 nm
<inline-formula><mml:math id="M331" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M332" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO <inline-formula><mml:math id="M333" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M334" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> Monitor that include physical and
electrical parameters like size, weight, and power requirements in addition to
figures of merit are provided in Table 1.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><caption><p id="d1e3989">Interference test results for FEM certification, 2B Technologies
model 405 nm <inline-formula><mml:math id="M335" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M336" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO <inline-formula><mml:math id="M337" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M338" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> folded tubular photometer.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Interferent</oasis:entry>
         <oasis:entry colname="col2">NO<inline-formula><mml:math id="M340" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Interferent</oasis:entry>
         <oasis:entry colname="col4">Response to</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">concentration, ppb</oasis:entry>
         <oasis:entry colname="col3">concentration, ppb<inline-formula><mml:math id="M341" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">interferent, ppb</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">NH<inline-formula><mml:math id="M342" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">0</oasis:entry>
         <oasis:entry colname="col3">100.9</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M343" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.5 <inline-formula><mml:math id="M344" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 1.2</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CO</oasis:entry>
         <oasis:entry colname="col2">99.1</oasis:entry>
         <oasis:entry colname="col3">50 700</oasis:entry>
         <oasis:entry colname="col4">1.2 <inline-formula><mml:math id="M345" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2.3</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">NO</oasis:entry>
         <oasis:entry colname="col2">99.8</oasis:entry>
         <oasis:entry colname="col3">509.6</oasis:entry>
         <oasis:entry colname="col4">0.6 <inline-formula><mml:math id="M346" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 1.9</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M347" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">101.2</oasis:entry>
         <oasis:entry colname="col3">500.0</oasis:entry>
         <oasis:entry colname="col4">0.2 <inline-formula><mml:math id="M348" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 3.9</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M349" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">100.9</oasis:entry>
         <oasis:entry colname="col3">519.7</oasis:entry>
         <oasis:entry colname="col4">0.1 <inline-formula><mml:math id="M350" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 1.9</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">H<inline-formula><mml:math id="M351" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O</oasis:entry>
         <oasis:entry colname="col2">101.8</oasis:entry>
         <oasis:entry colname="col3">20 150 ppm</oasis:entry>
         <oasis:entry colname="col4">0.3 <inline-formula><mml:math id="M352" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2.4</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e4026"><inline-formula><mml:math id="M339" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> Units for water vapor are ppm as noted.</p></table-wrap-foot></table-wrap>

</sec>
<sec id="Ch1.S3.SS3">
  <?xmltex \opttitle{Interferences in the measurement of NO${}_{{{2}}}$
and NO}?><title>Interferences in the measurement of NO<inline-formula><mml:math id="M353" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
and NO</title>
      <p id="d1e4292">Interferences in the UV-absorbance technique occur when either (1) other
species that absorb the same wavelengths of light as the analyte are also
removed by the scrubber or (2) species that can somehow affect light
transmission (such as the aforementioned water vapor interference in<?pagebreak page2829?> ozone
monitors) are altered by passing through the scrubber. In considering the
magnitude of possible interferences, one must consider both the ambient
concentration and the absorption cross section (for Eq. 1) of the interfering
species as well as whether it is removed or significantly interacts with the
scrubber. As part of the requirements for FEM designation, the model 405 nm
<inline-formula><mml:math id="M354" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M355" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO <inline-formula><mml:math id="M356" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M357" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> Monitor was tested for interferences
from high concentrations of common atmospheric constituents. Carbon monoxide,
nitric oxide, ozone, sulfur dioxide, and water vapor were added in the
presence of 100 ppb of <inline-formula><mml:math id="M358" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Ammonia was also tested without
<inline-formula><mml:math id="M359" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> present. None of these compounds exhibit absorbance at 405 nm,
but they can have large enough ambient concentrations to possibly influence
light transmission in the detection cells. However, all measured responses
were insignificant within statistical error, the highest response being
1.2 <inline-formula><mml:math id="M360" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2.3 ppb from 50.7 ppm of CO. Increasing the relative humidity
from dry (RH &lt; 1 %) to <inline-formula><mml:math id="M361" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 20 000 ppm of water vapor
(55 % RH at 24.8 <inline-formula><mml:math id="M362" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) gave an insignificant response of
0.3 <inline-formula><mml:math id="M363" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2.4 ppb. The results of interference testing are summarized in
Table 2.</p>
      <p id="d1e4382"><inline-formula><mml:math id="M364" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption at 405 nm is particularly attractive because there
are almost no airborne species that absorb significantly at this wavelength
other than <inline-formula><mml:math id="M365" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Aromatic compounds (which can present interferences
for ozone at 254 nm; Turnipseed et al., 2017) do not show significant
absorption above 300 nm (Keller-Rudek et al., 2013). Only multiple-ringed
aromatics are known to have significant absorption near 405 nm and their
gas-phase concentrations are exceedingly low (few ppt) due to their low vapor
pressures. These compounds tend to partition to the aerosol phase
(Finlayson-Pitts and Pitts, 2000), and particulates (along with any
extinction due to particulates) are removed by the inlet Teflon particle
filter of the instrument (Figs. 1, 3). HONO, NO<inline-formula><mml:math id="M366" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>, glyoxal, and methyl
glyoxal exhibit absorption near 405 nm (see Fig. 5), but the cross sections
of these compounds are <inline-formula><mml:math id="M367" display="inline"><mml:mo>≥</mml:mo></mml:math></inline-formula> 6 times less than <inline-formula><mml:math id="M368" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. NO<inline-formula><mml:math id="M369" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> is
highly reactive and is only present at low ppt levels at night near the
Earth's surface (Brown et al., 2007). Stutz et al. (2004) report that ratios
of [HONO] <inline-formula><mml:math id="M370" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> [<inline-formula><mml:math id="M371" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>] in urban areas reach maximum values of only
0.1 at night with concentrations of only a few ppb at most (Bernard et al.,
2016). Kebabian et al. (2008) report a minor interference from glyoxal and
methylglyoxal in their CAPS <inline-formula><mml:math id="M372" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> monitor during measurements in
Mexico City; however, the CAPS operated at a wavelength of 440 nm (with a
<inline-formula><mml:math id="M373" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>10 nm bandwidth), where the absorption cross section of both the glyoxal
and methylglyoxal is considerably larger (see Fig. 5). Both of these
compounds also have only been<?pagebreak page2830?> observed to be at most a few ppb even in
polluted urban atmospheres (Vrekoussis et al., 2009). At typical
concentration levels, interferences from all of these possible <inline-formula><mml:math id="M374" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
interferences are expected to be negligible at 405 nm.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><caption><p id="d1e4492">Absorption spectra of <inline-formula><mml:math id="M375" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and possible airborne
interferences (HONO, NO<inline-formula><mml:math id="M376" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>, glyoxal, methyl glyoxal) along with the
spectral output of the LED used in the model 405 nm.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f05.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><caption><p id="d1e4524">Plot of the NO measured in the folded tubular photometer vs.
<inline-formula><mml:math id="M377" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratio. The blue line is a linear fit to the data points
and yields a slope of <inline-formula><mml:math id="M378" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.4 ppb NO <inline-formula><mml:math id="M379" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> 100 ppb of <inline-formula><mml:math id="M380" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.
Corrected NO concentrations after application of Eq. (6) yield the orange and
green points using <inline-formula><mml:math id="M381" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations of 8 and 10 ppm,
respectively. Slopes decrease to <inline-formula><mml:math id="M382" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>1.3 ppb NO <inline-formula><mml:math id="M383" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> 100 ppb of
<inline-formula><mml:math id="M384" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M385" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.7 ppb NO <inline-formula><mml:math id="M386" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> 100 ppb <inline-formula><mml:math id="M387" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for the 8 and
10 ppm cases, respectively.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f06.png"/>

        </fig>

      <p id="d1e4631">As mentioned previously, NO is measured by quantitatively converting it to
<inline-formula><mml:math id="M388" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> by reaction with excess ozone (Eq. 3). Although this is a
simple bimolecular reaction with a known <inline-formula><mml:math id="M389" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> yield of unity,
subsequent chemistry could affect <inline-formula><mml:math id="M390" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations within the
photometer. Specifically, the large excess of ozone used (<inline-formula><mml:math id="M391" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 8 ppm) can
also slowly convert <inline-formula><mml:math id="M392" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M393" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> via:

                <disp-formula specific-use="align" content-type="numbered"><mml:math id="M394" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E4"><mml:mtd/><mml:mtd><mml:mstyle displaystyle="true" class="stylechange"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>→</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E5"><mml:mtd/><mml:mtd><mml:mstyle displaystyle="true" class="stylechange"/></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow><mml:mo>⇌</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            The reaction described by Eq. (4) is <inline-formula><mml:math id="M395" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 600 times slower than Eq. (3)
(<inline-formula><mml:math id="M396" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M397" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 3.22 <inline-formula><mml:math id="M398" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M399" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M400" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M401" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> s<inline-formula><mml:math id="M402" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>
at 298 K; Burkholder et al., 2015), yet can proceed to a small extent at
high NO<inline-formula><mml:math id="M403" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> levels. At room temperature and <inline-formula><mml:math id="M404" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations
greater than about 25 ppb, the Eq. (5) equilibrium favors <inline-formula><mml:math id="M405" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
formation and proceeds relatively rapidly (<inline-formula><mml:math id="M406" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 1.4 <inline-formula><mml:math id="M407" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M408" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M409" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M410" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> s<inline-formula><mml:math id="M411" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; Burkholder
et al., 2015), thus removing NO<inline-formula><mml:math id="M412" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> and resulting in a net loss of two
<inline-formula><mml:math id="M413" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> molecules. Loss of <inline-formula><mml:math id="M414" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> within the reaction coil and
detection cells due to Eqs. (4) and (5) will result in a slight increase in
light transmission, thereby causing an underestimate of the NO concentration.
Evidence for this chemistry was observed by adding <inline-formula><mml:math id="M415" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> to the
analyzer in the absence of NO (Fig. 6). As seen in the figure, measured NO
mixing ratios apparently decrease with increasing <inline-formula><mml:math id="M416" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. The linear
fit of the data gives a slope of <inline-formula><mml:math id="M417" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.4 ppb NO <inline-formula><mml:math id="M418" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> 100 ppb of
<inline-formula><mml:math id="M419" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Assuming that the reaction of NO<inline-formula><mml:math id="M420" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> with <inline-formula><mml:math id="M421" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is
fast and that the NO <inline-formula><mml:math id="M422" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M423" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> reaction goes to near completion before
significant <inline-formula><mml:math id="M424" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is lost via Eq. (4) (valid since <inline-formula><mml:math id="M425" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>k</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
<inline-formula><mml:math id="M426" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 600), a simple correction can be derived from assuming
pseudo-first-order kinetics, along with an estimate of [<inline-formula><mml:math id="M427" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>] from
the photolytic generator, measured [NO<inline-formula><mml:math id="M428" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>], the cell temperature, and cell
flow rate:
            <disp-formula id="Ch1.E6" content-type="numbered"><mml:math id="M429" display="block"><mml:mrow><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mi mathvariant="normal">NO</mml:mi><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">corr</mml:mi></mml:msub></mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mo>[</mml:mo><mml:msub><mml:mrow class="chem"><mml:mi mathvariant="normal">NO</mml:mi></mml:mrow><mml:mi>x</mml:mi></mml:msub><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">o</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:msub><mml:mi>k</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>[</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow><mml:mo>]</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:msup><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          Here, <inline-formula><mml:math id="M430" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mi mathvariant="normal">NO</mml:mi><mml:msub><mml:mo>]</mml:mo><mml:mi mathvariant="normal">corr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the amount of <inline-formula><mml:math id="M431" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> that is lost due to
Eqs. (4) and (5) and should be added to the measured NO concentration. The
residence time (<inline-formula><mml:math id="M432" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> in the reaction coil and optical cells is computed from
the effective reaction volume (reaction coil volume plus half the optical
cell volume) and the measured flow rate; <inline-formula><mml:math id="M433" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the temperature-dependent
rate coefficient of Eq. (4); and the factor of 2 results from the
stoichiometry of Eqs. (4) and (5). [<inline-formula><mml:math id="M434" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>] has been observed to vary
between 8 and 10 ppm for the typical flow rates and photolysis lamp
intensities (which are measured) used in the analyzer.
[NO<inline-formula><mml:math id="M435" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M436" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:math></inline-formula> is estimated as the sum of the most recently measured
<inline-formula><mml:math id="M437" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration and the most recently measured uncorrected NO
concentration. Using the uncorrected NO concentration to compute
[NO<inline-formula><mml:math id="M438" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M439" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:math></inline-formula> does cause a slight underestimation in the correction
(since NO is underestimated at this point). This underestimation can be
eliminated by applying this correction in an iterative fashion – computing a
corrected NO, then using this to recompute the [NO<inline-formula><mml:math id="M440" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M441" display="inline"><mml:msub><mml:mi/><mml:mi mathvariant="normal">o</mml:mi></mml:msub></mml:math></inline-formula>.
However, it was found that use of a single iteration resulted in corrections
that were within the instrumental measurement precision of those that used
only the uncorrected NO. As can be seen in Fig. 6, use of Eq. (1) over the
range of expected <inline-formula><mml:math id="M442" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratios reduces the observed NO bias by
a factor of 3 (to <inline-formula><mml:math id="M443" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M444" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>1 ppb NO <inline-formula><mml:math id="M445" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> 100 ppb NO<inline-formula><mml:math id="M446" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>). That the
bias is not completely removed may be due to Eq. (4) being slightly<?pagebreak page2831?> faster
than reported or, more likely, a heterogeneous contribution to Eq. (4) on
the optical cell walls. For ambient levels of NO and <inline-formula><mml:math id="M447" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, the
measurement error for NO is well within the noise of the instrument after
applying this correction in the firmware.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><caption><p id="d1e5384"><bold>(a)</bold> Time series comparison plot of ambient <inline-formula><mml:math id="M448" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
concentration measured outdoors at the Colorado Department of Public Health
and Environment (CDPHE) Interstate 25/Globeville roadside site using a
Teledyne API model T500U (lower data line in blue) and a folded tubular photometer (upper data line in red). Data for the folded tubular photometer
are offset for clarity by adding 50 ppb to the measurements. <bold>(b)</bold>
The same data, shown as a correlation plot.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f07.jpg"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8"><caption><p id="d1e5411"><bold>(a)</bold> Time series comparison plot of ambient NO concentration
measured outdoors at the CDPHE Interstate 25/Globeville roadside site using a
Teledyne API model 200E Chemiluminescence Analyzer (lower data line) and a
folded tubular photometer (upper data line). Data for the folded tubular photometer are offset for clarity by adding 400 ppb to the measurements.
<bold>(b)</bold> The same data, shown as a correlation plot. Data shown in the
bottom panel include the small correction for <inline-formula><mml:math id="M449" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> formation as
described in the text.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/2821/2018/amt-11-2821-2018-f08.jpg"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS4">
  <?xmltex \opttitle{Roadside measurements of NO${}_{{{2}}}$ and NO}?><title>Roadside measurements of NO<inline-formula><mml:math id="M450" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and NO</title>
      <p id="d1e5457">The folded tubular photometer (model 405 nm) was tested for <inline-formula><mml:math id="M451" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
and NO at a roadside monitoring site operated by the Colorado Department of
Public Health and Environment (CDPHE) in the fall of 2015 for 5 days. The
monitoring station was located along an entrance ramp at the intersection of
Interstate 25 and Interstate 70 just north of downtown Denver
(I-25/Globeville site; see
<uri>https://www.colorado.gov/airquality</uri> for site details; last access: 3 May 2018). Air was sampled through a Teflon inlet line that
was located within 1 m of the road at an approximate height of 4 m. Air was
drawn into the instrument shelter and sampled into three analyzers: (1) the
2B model 405 nm <inline-formula><mml:math id="M452" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>/NO/NO<inline-formula><mml:math id="M453" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> folded tubular photometer, (2) a
Teledyne-API model T500U CAPS
for <inline-formula><mml:math id="M454" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. and (3) a Teledyne-API model 200E NO <inline-formula><mml:math id="M455" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M456" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>
chemiluminescence monitor that reported both NO and <inline-formula><mml:math id="M457" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Both
the T500U and the 200E have either FEM or FRM (federal<?pagebreak page2832?> reference method)
designation and are operated by CDPHE as part of the State of Colorado's
ambient air quality monitoring network. The model 405 nm folded tubular photometer was operated at a flow rate of 1.6 L min<inline-formula><mml:math id="M458" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> in both a dual
mode for both <inline-formula><mml:math id="M459" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO for the first 4 days and then in a single
<inline-formula><mml:math id="M460" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>-only mode for 1 additional day. Unfiltered 5 s data from the
model 405 nm were logged and then averaged to 1 min for comparison with the
reference analyzers for <inline-formula><mml:math id="M461" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO.</p>
      <p id="d1e5579">Figure 7 shows the time series for 1 min averaged measurements of
<inline-formula><mml:math id="M462" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for both the model 405 nm folded tubular photometer and the
Teledyne-API CAPS. Note that the <inline-formula><mml:math id="M463" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> data for the folded tubular photometer plotted in Fig. 7 are shifted by 50 ppb for comparison purposes.
The agreement between the two data series is excellent, with both data sets
capturing the same sharp changes in concentration due to rapidly changing
concentrations in the roadside environment. Also shown is the correlation
plot for the data. The linear regression line of this plot has a slope of
0.968, an intercept of <inline-formula><mml:math id="M464" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.5 ppb, and a coefficient of correlation
(<inline-formula><mml:math id="M465" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) of 0.960.</p>
      <p id="d1e5622">Figure 8 compares the 1 min averaged measurements of NO mixing ratio using
the model 405 nm folded tubular photometer with simultaneous 1 min averaged
measurements made by the Teledyne API model 200E Chemiluminescence Analyzer. The method used by this analyzer, detection of chemiluminescence in the
reaction of NO with a large excess of ozone (Fontijn et al., 1970), is the
most common method used for ambient air measurements of nitric oxide. Data
for the folded tubular photometer are shifted in Fig. 8 by addition of
400 ppb for clarity. NO mixing ratios were not initially corrected for
<inline-formula><mml:math id="M466" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> formation (see Sect. 3.3). Yet the agreement between the
two measurement methods is excellent even when NO mixing ratios were changing
rapidly. The data are also shown as a correlation plot. The linear regression
yields a slope of 0.947, an intercept of <inline-formula><mml:math id="M467" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.2 ppb, and a coefficient of
correlation (<inline-formula><mml:math id="M468" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) of 0.976. Correction of the data for <inline-formula><mml:math id="M469" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
formation (Eq. 1) yielded a slope of 0.973 and an intercept of 0.3 ppb (the
correlation coefficient remained the same, 0.976), showing the small, but
significant, magnitude of the <inline-formula><mml:math id="M470" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> correction over this NO<inline-formula><mml:math id="M471" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>
concentration range. Note that once corrected, the correlation slope for NO
is identical to that of <inline-formula><mml:math id="M472" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. The slight deviation from unity for
these slopes is likely due to differences in calibration factors and possibly
due to small timing offsets caused by the slightly different inlet plumbing
between the instruments in a roadside sampling environment where
concentrations were highly variable and changing rapidly.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <title>Conclusions and future directions</title>
      <p id="d1e5719">We have developed and characterized a new instrumental method, the folded tubular photometer, for measurements of ambient concentrations of both
<inline-formula><mml:math id="M473" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO in air. The instrument is commercially available as the
model 405 nm <inline-formula><mml:math id="M474" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M475" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO <inline-formula><mml:math id="M476" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> NO<inline-formula><mml:math id="M477" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> Monitor (2B Technologies,
Inc., Boulder, CO). A design using a folded tubular optical bench yields long
path lengths with low cell volumes, thereby enabling <inline-formula><mml:math id="M478" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> to be
measured directly via optical absorbance at 405 nm. This is sometimes
referred to as “true <inline-formula><mml:math id="M479" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>” and is essentially interference-free.
The instrument measures NO by conversion to <inline-formula><mml:math id="M480" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> via the addition of
ozone, thus enabling the full characterization of NO<inline-formula><mml:math id="M481" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>
(NO <inline-formula><mml:math id="M482" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M483" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) needed for photochemical modeling. The optical bench
is modular and can have variable path lengths of up to 2 m or longer. The
cell design makes it possible to measure other species that are typically
difficult to measure by direct absorption photometry, such as <inline-formula><mml:math id="M484" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
and black carbon. Pressure equalization during the various stages of the
absorbance measurement cycle is critical to obtaining accurate measurements
of the analyte.</p>
      <p id="d1e5840">The most common method to measure <inline-formula><mml:math id="M485" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> has long been reduction to
NO, followed by chemiluminescence with ozone (Fontijn et al., 1970). This
indirect technique has several disadvantages. The most common means of
<inline-formula><mml:math id="M486" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> reduction involves passing the air sample through a heated
molybdenum catalyst bed (Winer et al., 1974). However, it has been well
established that other nitrogen species in the atmosphere, especially
peroxyacetyl nitrates (PANs), <inline-formula><mml:math id="M487" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and nitric acid (HNO<inline-formula><mml:math id="M488" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>),
may be converted as well (Winer et al., 1974; Dunlea et al., 2007). It is
often observed that the conversion efficiency for <inline-formula><mml:math id="M489" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is not unity
or changes with extended use as required by long-term monitoring. Photolytic
reduction of <inline-formula><mml:math id="M490" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> to NO is more selective (Parrish et al., 1990;
Parrish and Fehsenfeld, 2000; Buhr, 2007), yet the photolytic conversion is
often much less than unity (typically <inline-formula><mml:math id="M491" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 50 %). Furthermore, a
photochemical equilibrium is established within the photoreactor between NO,
<inline-formula><mml:math id="M492" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M493" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> resulting in a dependency of the conversion
efficiency on the ambient concentration of ozone (Parrish et al., 1990).
Recent work in extremely polluted environments (tunnels with high vehicle
traffic) also shows evidence for undesired photochemistry from hydrocarbons
that biases the <inline-formula><mml:math id="M494" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements (Villena et al., 2012).
Furthermore, regardless of the conversion method, the measurement of
<inline-formula><mml:math id="M495" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is indirect, being calculated from the difference between
measurements of NO<inline-formula><mml:math id="M496" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math id="M497" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M498" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> NO) obtained by passing through
the converter and measurements of NO without passing through the converter.</p>
      <p id="d1e5992">Direct measurement of <inline-formula><mml:math id="M499" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> by absorption photometry, such as in the
folded tubular photometer described here, avoids the problems of this
long-established indirect chemiluminescence method. Laser-induced
fluorescence (LIF) and tunable diode laser absorption spectroscopy (TDLAS)
have both been used successfully by several researchers to directly measure
<inline-formula><mml:math id="M500" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (e.g., Thornton et al., 2000; Schiff et al., 1990); however,
these techniques are often quite complicated, requiring significant expertise
to operate, and currently there are no commercial instruments available.
CRDS and CAPS are also direct <inline-formula><mml:math id="M501" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurement techniques based on
light absorption at 405 and 450 nm, respectively, and are also commercially
available (Kebabian et al., 2008; Beaver et al.,<?pagebreak page2833?> 2013). These systems use a
high-finesse optical cavity to reflect the optical light beam multiple times
to generate very long path lengths, thus increasing the sensitivity. The
sensitivity of these cavity-based techniques is greater than the single-pass
folded tubular photometer absorbance analyzer described here and likely more
suitable for rural and clean environments; however, these come at higher cost
primarily due to the expense of the high-finesse cavities and associated
optics. Our intercomparisons of <inline-formula><mml:math id="M502" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements made by the folded tubular photometer and a CAPS <inline-formula><mml:math id="M503" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> analyzer in a highly trafficked
roadside environment showed excellent agreement for concentrations up to
<inline-formula><mml:math id="M504" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 ppb (as large of a range as one would expect for ambient
measurements). Thus, the folded tubular photometer can achieve comparable
measurement accuracy at concentration levels typical for air quality
monitoring at less cost.</p>
      <p id="d1e6058">Furthermore, manufacturers of the commercially available CRDS and CAPS
instruments do not currently offer a concurrent measurement of NO. Since NO
and <inline-formula><mml:math id="M505" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are in rapid photochemical equilibrium, measurements of
both are required to fully characterize either ambient concentrations or
emissions from industrial sources. Certainly both are needed as inputs to
regional chemical-transport models that predict air quality. As demonstrated
here, the low cell volume allows the folded tubular photometer method to
convert NO to <inline-formula><mml:math id="M506" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> via addition of ozone, thereby enabling accurate
measurements of NO in the model 405 nm folded tubular photometer. Even
though this measurement of NO is indirect in nature, the conversion
efficiency is near unity, and we observed excellent agreement in a roadside
intercomparison with the standard NO chemiluminescence technique for
concentrations up to 500 ppb of NO. Slight corrections are necessary due to
<inline-formula><mml:math id="M507" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> formation in the photochemical reaction coil, but these are
typically small – less than 3 % in the observed roadside study – and
correctible within the firmware by means of a simple kinetics model.</p>
      <p id="d1e6100">In summary, compared to other available instruments, the folded tubular photometer method provides a direct, accurate measure of <inline-formula><mml:math id="M508" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, also
measures NO, is less expensive, and is smaller, lighter, and consumes less
power, making it an attractive alternative for compliance monitoring sites
and field measurements of these important atmospheric species. As with
absorption photometers for ozone, calibration depends primarily on the known
path length and absorption cross section and does not vary in time. Thus the
folded tubular photometer provides the robust, accurate measurement of
<inline-formula><mml:math id="M509" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO that is necessary for long-term compliance monitoring.</p>
      <p id="d1e6125">As suggested in Sect. 1, the folded tubular photometer may be applied to
direct measurements of other atmospherically significant species including
<inline-formula><mml:math id="M510" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M511" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and optical extinction of aerosols for
characterization of particulates. Sulfur dioxide has typically been measured
by fluorescence (Schwarz et al., 1974). However, absorbance has the advantage
of being an absolute method, requiring only infrequent calibration.
Instruments based on absorbance are typically less expensive to construct
than fluorescence-based instruments and require less power because a high-intensity light source is not required. Thus, an instrument based on direct
absorbance of <inline-formula><mml:math id="M512" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> would have advantages over fluorescence, at least
in those applications where it provides adequate sensitivity. Ambient ozone
also is a significant interference for <inline-formula><mml:math id="M513" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> as it absorbs in the
same region as <inline-formula><mml:math id="M514" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Keller-Rudek et al., 2013) and is typically
present at much higher concentrations. However, direct absorbance measurement
of <inline-formula><mml:math id="M515" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> could be useful in applications such as smokestack
monitoring for <inline-formula><mml:math id="M516" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emissions in the combustion of fossil fuels such
as coal or natural gas. Here, concentrations are relatively large, ozone is
absent, and a more robust instrument requiring little maintenance and
infrequent calibration is desirable.</p>
      <p id="d1e6206">The folded tubular photometer can also be applied to measurements of
particulate extinction (defined as the sum of aerosol light absorption and
scattering). Large multipass extinction cells have been used (e.g., Schnaiter
et al., 2005), but lack the necessary precision due to the inability to flush
the large volume cells, as discussed in Sect. 1. Cavity techniques (CRDS and
CAPS) have both been applied successfully to particulate extinction
(Moosmüller et al., 2005; Massoli et al., 2010), but the highly
reflective mirrors required in these cavities only operate over a small range
of wavelengths (10–50 nm) (Zhao et al., 2014; Washenfelder et al., 2013).
Thus, they are incapable of measuring across wide spectral ranges (e.g., from
UV to the near IR) without the use of multiple cavities, which would add
significant cost. Understanding the spectral dependence of particulate
extinction is often desired to infer both aerosol size and composition. The
mirrors used in the folded-tubular-photometer-based analyzer have adequate
reflectivity (&gt; 90 %) from 350 to 1000 nm; therefore,
multiple wavelengths of light from different LED sources can be combined via
dichroic mirrors or by fiber optics and passed through the detection cells.</p>
      <?pagebreak page2834?><p id="d1e6209">In polluted urban areas, extinction in the near IR (<inline-formula><mml:math id="M517" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 880 nm, where
light scattering by sub-micron particles is weak) can approximate absorption
by black carbon. Although not specifically regulated in the US, black carbon
has been linked to numerous cardiorespiratory illnesses (US-EPA, 2012).
Black carbon has long been measured by the method of aethalometry whereby
particulate matter is continuously deposited on a filter and transmission of
light through the filter is continuously monitored (Hansen et al., 1982).
However, aethalometers have been shown to have several artifacts associated
with light scattering by the filter medium, loading corrections, and
agglomeration of particulates (Weingartner et al., 2003; Arnott et al., 2005;
Coen et al., 2010; Baumgardner et al., 2012). Our preliminary work suggests
that aerosol extinction can be measured with a precision of
&lt; 1 Mm<inline-formula><mml:math id="M518" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (for a 1 min average at either 405 or 880 nm) with
an optical cell similar to that described here for <inline-formula><mml:math id="M519" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, which could
provide an accurate estimate of black carbon concentrations in urban areas,
free from the artifacts caused by filter collection.</p>
      <p id="d1e6242">These examples represent a few possibilities for the folded tubular photometer. We have demonstrated its usefulness in the measurements of
<inline-formula><mml:math id="M520" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and NO. For other species it has the potential for providing
accurate measurements with a robust technique (akin to the long-standing
absorbance method of measuring ozone) that needs infrequent calibration and
can be produced at lower cost than existing technologies.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability">

      <p id="d1e6261">Experimental data presented here are available upon request to the authors (johnb@twobtech.com).</p>
  </notes><notes notes-type="competinginterests">

      <p id="d1e6267">Several authors are affiliated with 2B Technologies,
Inc., the manufacturer of the folded tubular photometer. John Birks,
Peter Andersen, Craig Williford, Andrew Turnipseed, Stanley Strunk and
Christine Ennis are employed by 2B Technologies, Inc., the manufacturer of
the folded tubular photometer.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e6273">Air Resource Specialists, Inc. of Fort Collins, Colorado, provided the
external testing for EPA Federal Equivalent Method certification.
<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?> Edited by: Lisa Whalley <?xmltex \hack{\newline}?>
Reviewed by: two anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Allen, C., Carrico, C., Gomez, S., Andersen, P., Turnipseed, A., Williford,
C., Birks, J., Carrion, R., Gates, D., Macias, F., Rahn, T., Aiken, A., and
Dubey, M.: NO<inline-formula><mml:math id="M521" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> Instrument Intercomparison for Laboratory Biomass Burning
Source Studies and Urban Ambient Measurements in Albuquerque, New Mexico,
J. Air Waste Manage., in review, 2018.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>
Arnott, W. P., Hamasha, K., Moosmüller, H., Sheridan, P. J., and Ogren,
J. A.: Towards aerosol light-absorption measurements with a 7-wavelength
aethalometer: Evaluation with a photoacoustic instrument and 3-wavelength
nephelometer, Aerosol Sci. Tech., 39, 17–29, 2005.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>Baumgardner, D., Popovicheva, O., Allan, J., Bernardoni, V., Cao, J.,
Cavalli, F., Cozic, J., Diapouli, E., Eleftheriadis, K., Genberg, P. J.,
Gonzalez, C., Gysel, M., John, A., Kirchstetter, T. W., Kuhlbusch, T. A. J.,
Laborde, M., Lack, D., Müller, T., Niessner, R., Petzold, A.,
Piazzalunga, A., Putaud, J. P., Schwarz, J., Sheridan, P., Subramanian, R.,
Swietlicki, E., Valli, G., Vecchi, R., and Viana, M.: Soot reference
materials for instrument calibration and intercomparisons: A workshop summary
with recommendations, Atmos. Meas. Tech., 5, 1869–1887,
<ext-link xlink:href="https://doi.org/10.5194/amt-5-1869-2012" ext-link-type="DOI">10.5194/amt-5-1869-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Beaver, M., Kronmiller, K., Duvall, R., Kaushik, S., Morphy, T., King, P.,
and Long, R.: Direct and indirect methods for the measurement of nitrogen
dioxide (NO<inline-formula><mml:math id="M522" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>), Presented at AWMA Measurements Meeting, Sacramento, CA,
20 November 2013.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>
Bernard, F., Cazaunau, M., Grosselin, B., Zhou, B., Zheng, J., Liang, P.,
Zhang, Y., Ye, X., Daele, V., Mu, Y., Zhang, R., Chen, J., and Mellouki, A.:
Measurements of nitrous acid (HONO) in urban area of Shanghai, China,
Environ. Sci. Pollut. Res., 23, 5818–5829, 2016.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Birks, J. W.: Oxidant formation in the troposphere, in: Perspectives in
Environmental Chemistry, edited by: Macalady, D. L., Oxford University Press,
233–256, 1998.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>
Birks, J. W., Shoemaker, B., Leck, T. J., and Hinton, D. M.: Studies of
reactions of importance in the stratosphere, I. Reaction of nitric oxide with
ozone, J. Chem. Phys., 65, 5181–5185, 1976.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>Borders, R. A. and Birks, J. W.: High precision measurements of activation
energies over small temperature intervals: Curvature in the Arrhenius plot
for the reaction NO <inline-formula><mml:math id="M523" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> O<inline-formula><mml:math id="M524" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>→</mml:mo></mml:mrow></mml:math></inline-formula> NO<inline-formula><mml:math id="M525" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>+</mml:mo></mml:mrow></mml:math></inline-formula> O<inline-formula><mml:math id="M526" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, J. Phys. Chem.,
86, 3295–3302, 1982.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>Brown, S. S., Dubé, W. P., Osthoff, H. D., Stutz, J., Ryerson, T. B.,
Wollny, A. G., Brock, C. A., Warneke, C., de Gouw, J. A., Atlas, E. J.,
Neuman, A., Holloway, J. S., Lerner, B. M., Williams, E. J., Kuster, W. C.,
Goldan, P. D., Angevine, W. M., Trainer, M., Fehsenfeld, F. C., and
Ravishankara, A. R.: Vertical profiles of <inline-formula><mml:math id="M527" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M528" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
measured from an aircraft: Results from the NOAA P-3 and surface platforms
during the New England Air Quality Study 2004, J. Geophys. Res., 112, D22304,
<ext-link xlink:href="https://doi.org/10.1029/2007JD008883" ext-link-type="DOI">10.1029/2007JD008883</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>
Buhr, M. P.: Solid-state light source photolytic nitrogen dioxide converter,
US Patent US7238328 B2, US Patent and Trademark Office, Washington, DC, USA,
2007.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Burkholder, J. B., Sander, S. P., Abbatt, J., Barker, J. R., Huie, R. E.,
Kolb, C. E., Kurylo, M. J., Orkin, V. L., Wilmouth, D. M., and Wine, P. H.:
Chemical Kinetics and Photochemical Data for Use in Atmospheric Studies,
Evaluation No. 18, JPL Publication 15–10, Jet Propulsion Laboratory,
Pasadena, 2015.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Burrows, J. P., Dehn, A., Deters, B., Himmelmann, S., Richter, A., Voigt, S.,
and Orphal, J.: Atmospheric remote-sensing reference data from GOME: Part 1.
Temperature-dependent absorption cross-sections of <inline-formula><mml:math id="M529" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in the
231–794 nm range, J. Quant. Spectrosc. Ra., 60, 1025–1031, 1998.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>Coen, M. C., Weingartner, E., Apituley, A., Ceburnis, D., Fierz-Schmidhauser,
R., Flentje, H., Henzing, J. S., Jennings, S. G., Moerman, M., Petzold, A.,
Schmid, O., and Baltensperger U.: Minimizing light absorption measurement
artifacts of the Aethalometer: Evaluation of five correction algorithms,
Atmos. Meas. Tech., 3, 457–474, <ext-link xlink:href="https://doi.org/10.5194/amt-3-457-2010" ext-link-type="DOI">10.5194/amt-3-457-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>
Crosson, E. R.: A cavity ring-down analyzer for measuring atmospheric levels
of methane, carbon dioxide, and water vapor, Appl. Phys. B, 92, 403–408,
2008.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>Drinovec, L., Mocnik, G., Zotter, P., Prevot, A. S. H., Ruckstuhl, C., Coz,
E., Rupakheti, M., Sciare, J., Muller, T., Wiedensohler, A., and Hansen, A.
D. A: The Dual Spot Aethalometer: An improved measurement of aerosol black
carbon with real-time loading compensation, Atmos. Meas. Tech., 8,
1965–1979, <ext-link xlink:href="https://doi.org/10.5194/amt-8-1965-2015" ext-link-type="DOI">10.5194/amt-8-1965-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>Dunlea, E. J., Herndon, S. C., Nelson, D. D., Volkamer, R. M., San Martini,
F., Sheehy, P. M., Zahniser, M. S., Shorter, J. H., Wormhoudy, J. C., Lamb,
B. K., Allwine, E. J., Gaffney, J. S., Marley, N. A., Grutter, M., Marquez,
C., Blanco, S., Cardenas, B., Retama, A., Ramos-Villegas, C. R., Kolb, C. E.,
Molina, L. T., and Molina, M. J.: Evaluation of nitrogen<?pagebreak page2835?> dioxide
chemiluminescence monitors in a polluted urban environment, Atmos. Chem.
Phys., 7, 2691–2704, <ext-link xlink:href="https://doi.org/10.5194/acp-7-2691-2007" ext-link-type="DOI">10.5194/acp-7-2691-2007</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Finlayson-Pitts, B. J. and Pitts, J. N.: Chemistry of the Upper and Lower
Atmosphere: Theory, Experiments and Applications, Academic Press, San Diego,
2000.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
Fontijn, A., Sabadell, A. J., and Ronco, R. J.: Homogenous chemiluminescent
measurement of nitric oxide with ozone, Anal. Chem., 42, 575–579, 1970.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>
Haagen-Smit, A. J. and Fox, M. M.: Photochemical ozone formation with
hydrocarbons and automobile exhaust, J. Air Pollut. Control Assoc., 4,
105–108, 1954.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>
Hansen, A. D. A., Rosen, H., and Novakov, T.: Real-time measurement of the
aerosol absorption-coefficient of aerosol particles, Appl. Opt., 21,
3060–3062, 1982.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>
Herriott, D. and Schulte, H.: Folded optical delay lines, Appl. Opt., 4,
883–889, 1965.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>
Kebabian, P. L., Herndon, S. C., and Freedman, A.: Detection of nitrogen
dioxide by cavity attenuated phase shift spectroscopy, Anal. Chem., 77,
724–728, 2005.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>
Kebabian, P. L., Wood, E. C., Herndon, S. C., and Freedman, A.: A practical
alternative to chemiluminescence-based detection of nitrogen dioxide: Cavity
attenuated phase shift spectroscopy, Environ. Sci. Tech., 42, 6040–6045,
2008.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>Keller-Rudek, H., Moortgat, G. K., Sander, R., and Sörensen, R.: The
MPI-Mainz UV/VIS spectral atlas of gaseous molecules of atmospheric interest,
Earth Syst. Sci. Data, 5, 365–373, <ext-link xlink:href="https://doi.org/10.5194/essd-5-365-2013" ext-link-type="DOI">10.5194/essd-5-365-2013</ext-link>,
2013.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>
Massoli, P., Kebabian, P. L., Onasch, T. B., Hills, F. B., and Freedman, A.:
Aerosol light extinction measurements by Cavity Attenuated Phase Shift (CAPS)
Spectroscopy: Laboratory validation and field deployment of a compact aerosol
particle extinction monitor, Aerosol Sci. Technol., 44, 428–435, 2010.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>
Moosmüller, H., Varma, R., and Arnott, W. P.: Cavity ring-down and
cavity-enhanced detection techniques for the measurement of aerosol
extinction, Aerosol Sci. Technol., 39, 30–39, 2005.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>
Paldus, B. A. and Kachanov, A. A.: Spectroscopic techniques: Cavity-enhanced
methods, in: Atomic, Molecular, and Optical Physics Handbook, Part C:
Molecules, edited by: Drake, G. W. F., Springer, Berlin, 621–640, 2004.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>
Parrish, D. D. and Fehsenfeld, F. C.: Methods for gas-phase measurements of
ozone, ozone precursors and aerosol precursors, Atmos. Environ., 34,
1921–1957, 2000.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>Parrish, D. D., Hahn, C. H., Fahey, D. W., Williams, E. J., Bollinger, M. J.,
Hübler, G., Buhr, M. P., Murphy, P. C., Trainer, M., Hsie, E. Y., Liu, S.
C., and Fehsenfeld, F. C.: Systematic variations in the concentration of
NO<inline-formula><mml:math id="M530" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>(NO plus NO<inline-formula><mml:math id="M531" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) at Niwot Ridge, Colorado, J. Geophys. Res., 95,
1817–1836, 1990.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
Platt, U.: Differential optical absorption spectroscopy (DOAS), Chem. Anal.
Series, 127, 27–83, 1994.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>
Schiff, H. I., Karecki, D. R., Harris, G. W., Hastie, E. R., and MacKay, G.
I.: A tunable diode laser system for aircraft measurements of trace gases, J.
Geophys. Res., 95, 147–153, 1990.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>Schnaiter, M., Schmid, O., Petzold, A., Fritzsche, L., Klein, K. F., Andreae,
M. O., Helas, G., Thielmann, A., Gimmler, M., Möhler, O., Linke, C., and
Schurath, U.: Measurement of wavelength-resolved light absorption by aerosols
utilizing a UV-VIS extinction cell, Aerosol Sci. Technol., 39, 249–260,
2005.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>
Schwarz, F. P., Okabe, H., and Whittaker, J. K.: Fluorescence detection of
sulfur dioxide in air at the parts per billion level, Anal. Chem., 46,
1024–1028, 1974.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>Stutz, J., Alicke, B., Ackermann, R., Geyer, A., Wang, S., White, A. B.,
Williams, E. J., Spicer, C. W., and Fast, D.: Relative humidity dependence of
HONO chemistry in urban areas, J. Geophys. Res., 109, D03307,
<ext-link xlink:href="https://doi.org/10.1029/2003JD004135" ext-link-type="DOI">10.1029/2003JD004135</ext-link>,2004.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>
Thornton, J. A., Wooldridge, P. J., and Cohen, R. C.: Atmospheric NO2: In
situ laser-induced fluorescence detection at parts per trillion mixing
ratios, Anal. Chem., 72, 528–539, 2000.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>Turnipseed, A. A., Andersen, P. C., Williford, C. J., Ennis, C. A., and
Birks, J. W.: Use of a heated graphite scrubber as a means of reducing
interferences in UV-absorbance measurements of atmospheric ozone, Atmos.
Meas. Tech., 10, 2253–2269, <ext-link xlink:href="https://doi.org/10.5194/amt-10-2253-2017" ext-link-type="DOI">10.5194/amt-10-2253-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>
US-EPA: Report to the Congress on Black Carbon, Department of the Interior,
Environment and Related Agencies, 351 pp., 2012.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><mixed-citation>Vandaele, A. C., Simon, P. C., Guilmot, J. M., Carleer, M., and Colin, R.:
<inline-formula><mml:math id="M532" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption cross section measurement in the UV using a Fourier
transform spectrometer, J. Geophys. Res., 99, 25599–25605, 1994.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation>Villena, G. Bejan, I., Kurtenback, R., Wiesen, P., and Kleffmann, J.:
Interferences of commercial <inline-formula><mml:math id="M533" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> instruments in the urban atmosphere
and in a smog chamber, Atmos. Meas. Tech., 5, 149–159,
<ext-link xlink:href="https://doi.org/10.5194/amt-5-149-2012" ext-link-type="DOI">10.5194/amt-5-149-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><mixed-citation>Vrekoussis, M., Wittrock, F., Richter, A., and Burrows, J. P.: Temporal and
spatial variability of glyoxal as observed from space, Atmos. Chem. Phys., 9,
4485–4504, <ext-link xlink:href="https://doi.org/10.5194/acp-9-4485-2009" ext-link-type="DOI">10.5194/acp-9-4485-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><mixed-citation>Washenfelder, R. A., Flores, J. M., Brock, C. A., Brown, S. S., and Rudich,
Y.: Broadband measurements of aerosols extinction in the ultraviolet spectral
region, Atmos. Meas. Tech., 6, 861–877,
<ext-link xlink:href="https://doi.org/10.5194/amt-6-861-2013" ext-link-type="DOI">10.5194/amt-6-861-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><mixed-citation>
Weingartner, E., Saathoff, H., Schnaiter, M., Streit, N., Bitnar, B., and
Baltensperger, U.: Absorption of light by soot particles: Determination of
the absorption coefficients by means of aethalometers, J. Aerosol Sci., 34,
1445–1463, 2003.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><mixed-citation>
White, J. U.: Long optical paths of large aperture, J. Opt. Soc. Am., 32,
285–288, 1942.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><mixed-citation>
Wilson, K. L. and Birks, J. W.: Mechanism and elimination of a water vapor
interference in the measurement of ozone by UV absorbance, Environ. Sci.
Technol., 40, 6361–6367, 2006.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><mixed-citation>Winer, A. M., Peters, J. W., Smith, J. P., and Pitts, J. N.: Response of
commercial chemiluminescent NO-<inline-formula><mml:math id="M534" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> analyzers to other
nitrogen-containing compounds, Environ. Sci. Technol., 8, 1118–1121, 1974.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><mixed-citation>World Health Organization: Burden of disease from Household Air Pollution for
2012,
<uri>http://www.who.int/entity/phe/health_topics/outdoorair/databases/FINAL_HAP_AAP_BoD_24March2014.pdf?ua={1}</uri>,
last access: December 2017, 2014.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><mixed-citation>Zhao, W., Xu, X., Dong, M., Chen, W., Gu, X., Hu, C., Huang, Y., Gao, X.,
Huang, W., and Zhang, W.: Development of a cavity-enhanced aerosol
albedometer, Atmos. Meas. Tech., 7, 2551–2566,
<ext-link xlink:href="https://doi.org/10.5194/amt-7-2551-2014" ext-link-type="DOI">10.5194/amt-7-2551-2014</ext-link>, 2014.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Folded tubular photometer for atmospheric measurements of NO<sub>2</sub> and NO</article-title-html>
<abstract-html><p>We describe and characterize a modular folded tubular photometer
for making direct measurements of the concentrations of nitrogen dioxide
(NO<sub>2</sub>) and specify how this method could be extended to measure other
pollutants such as sulfur dioxide (SO<sub>2</sub>), ozone (O<sub>3</sub>), and black
carbon particulate matter. Direct absorbance measurements using this
photometer can be made across the spectral range from the ultraviolet (UV) to
the near infrared. The absorbance cell makes use of modular components
(tubular detection cells and mirror cubes) that allow construction of path
lengths of up to 2&thinsp;m or more while maintaining low cell volumes. The long
path lengths and low cell volumes enable sensitive detection of ambient air
pollutants down to low part-per-billion levels for gas species and aerosol
extinctions down to 1&thinsp;Mm<sup>−1</sup>, corresponding to
 ∼ &thinsp;0.1&thinsp;µg&thinsp;m<sup>−3</sup> for black carbon particulates. Pressure
equalization throughout the stages of the absorbance measurement is shown to
be critical to accurate measurements of analyte concentrations. The present
paper describes the application of this photometer to direct measurements of
nitrogen dioxide (NO<sub>2</sub>) and the incorporation of design features that
also enable measurement of nitric oxide (NO) in the same instrument.
Excellent agreement for ambient measurements along an urban roadside was
found for both NO<sub>2</sub> and NO measured by the folded tubular photometer
compared to existing standard techniques. Compared to commonly used methods
for measurements of NO<sub><i>x</i></sub> species, the advantages of this approach include
(1) an absolute quantification for NO<sub>2</sub> based on the Beer–Lambert
law, thereby greatly reducing the frequency at which calibrations are
required; (2) the direct measurement of NO<sub>2</sub> concentration without
prior conversion to NO as is required for the commonly used chemiluminescence
method; (3) the use of modular components that allow construction of
absorbance detection cells of varying lengths for extending the dynamic range
of concentrations that can be measured; (4) a more economical instrument than
other currently available direct measurement techniques for NO<sub>2</sub>;
and (5) the potential for simultaneous detection of additional species such
as SO<sub>2</sub>, O<sub>3</sub>, and black carbon in the same instrument. In
contrast to other commercially available direct NO<sub>2</sub> measurements,
such as cavity-attenuated phase-shift spectroscopy (CAPS), the folded tubular photometer also measures NO simultaneously in the same apparatus by
quantitatively converting NO to NO<sub>2</sub> with ozone, which is then
detected by direct absorbance.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Allen, C., Carrico, C., Gomez, S., Andersen, P., Turnipseed, A., Williford,
C., Birks, J., Carrion, R., Gates, D., Macias, F., Rahn, T., Aiken, A., and
Dubey, M.: NO<sub><i>x</i></sub> Instrument Intercomparison for Laboratory Biomass Burning
Source Studies and Urban Ambient Measurements in Albuquerque, New Mexico,
J. Air Waste Manage., in review, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Arnott, W. P., Hamasha, K., Moosmüller, H., Sheridan, P. J., and Ogren,
J. A.: Towards aerosol light-absorption measurements with a 7-wavelength
aethalometer: Evaluation with a photoacoustic instrument and 3-wavelength
nephelometer, Aerosol Sci. Tech., 39, 17–29, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Baumgardner, D., Popovicheva, O., Allan, J., Bernardoni, V., Cao, J.,
Cavalli, F., Cozic, J., Diapouli, E., Eleftheriadis, K., Genberg, P. J.,
Gonzalez, C., Gysel, M., John, A., Kirchstetter, T. W., Kuhlbusch, T. A. J.,
Laborde, M., Lack, D., Müller, T., Niessner, R., Petzold, A.,
Piazzalunga, A., Putaud, J. P., Schwarz, J., Sheridan, P., Subramanian, R.,
Swietlicki, E., Valli, G., Vecchi, R., and Viana, M.: Soot reference
materials for instrument calibration and intercomparisons: A workshop summary
with recommendations, Atmos. Meas. Tech., 5, 1869–1887,
<a href="https://doi.org/10.5194/amt-5-1869-2012" target="_blank">https://doi.org/10.5194/amt-5-1869-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Beaver, M., Kronmiller, K., Duvall, R., Kaushik, S., Morphy, T., King, P.,
and Long, R.: Direct and indirect methods for the measurement of nitrogen
dioxide (NO<sub>2</sub>), Presented at AWMA Measurements Meeting, Sacramento, CA,
20 November 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Bernard, F., Cazaunau, M., Grosselin, B., Zhou, B., Zheng, J., Liang, P.,
Zhang, Y., Ye, X., Daele, V., Mu, Y., Zhang, R., Chen, J., and Mellouki, A.:
Measurements of nitrous acid (HONO) in urban area of Shanghai, China,
Environ. Sci. Pollut. Res., 23, 5818–5829, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Birks, J. W.: Oxidant formation in the troposphere, in: Perspectives in
Environmental Chemistry, edited by: Macalady, D. L., Oxford University Press,
233–256, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Birks, J. W., Shoemaker, B., Leck, T. J., and Hinton, D. M.: Studies of
reactions of importance in the stratosphere, I. Reaction of nitric oxide with
ozone, J. Chem. Phys., 65, 5181–5185, 1976.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Borders, R. A. and Birks, J. W.: High precision measurements of activation
energies over small temperature intervals: Curvature in the Arrhenius plot
for the reaction NO&thinsp;+&thinsp;O<sub>3</sub> → &thinsp;NO<sub>2</sub>+&thinsp;O<sub>2</sub>, J. Phys. Chem.,
86, 3295–3302, 1982.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Brown, S. S., Dubé, W. P., Osthoff, H. D., Stutz, J., Ryerson, T. B.,
Wollny, A. G., Brock, C. A., Warneke, C., de Gouw, J. A., Atlas, E. J.,
Neuman, A., Holloway, J. S., Lerner, B. M., Williams, E. J., Kuster, W. C.,
Goldan, P. D., Angevine, W. M., Trainer, M., Fehsenfeld, F. C., and
Ravishankara, A. R.: Vertical profiles of NO<sub>3</sub> and N<sub>2</sub>O<sub>5</sub>
measured from an aircraft: Results from the NOAA P-3 and surface platforms
during the New England Air Quality Study 2004, J. Geophys. Res., 112, D22304,
<a href="https://doi.org/10.1029/2007JD008883" target="_blank">https://doi.org/10.1029/2007JD008883</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Buhr, M. P.: Solid-state light source photolytic nitrogen dioxide converter,
US Patent US7238328 B2, US Patent and Trademark Office, Washington, DC, USA,
2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Burkholder, J. B., Sander, S. P., Abbatt, J., Barker, J. R., Huie, R. E.,
Kolb, C. E., Kurylo, M. J., Orkin, V. L., Wilmouth, D. M., and Wine, P. H.:
Chemical Kinetics and Photochemical Data for Use in Atmospheric Studies,
Evaluation No. 18, JPL Publication 15–10, Jet Propulsion Laboratory,
Pasadena, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Burrows, J. P., Dehn, A., Deters, B., Himmelmann, S., Richter, A., Voigt, S.,
and Orphal, J.: Atmospheric remote-sensing reference data from GOME: Part 1.
Temperature-dependent absorption cross-sections of NO<sub>2</sub> in the
231–794&thinsp;nm range, J. Quant. Spectrosc. Ra., 60, 1025–1031, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Coen, M. C., Weingartner, E., Apituley, A., Ceburnis, D., Fierz-Schmidhauser,
R., Flentje, H., Henzing, J. S., Jennings, S. G., Moerman, M., Petzold, A.,
Schmid, O., and Baltensperger U.: Minimizing light absorption measurement
artifacts of the Aethalometer: Evaluation of five correction algorithms,
Atmos. Meas. Tech., 3, 457–474, <a href="https://doi.org/10.5194/amt-3-457-2010" target="_blank">https://doi.org/10.5194/amt-3-457-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Crosson, E. R.: A cavity ring-down analyzer for measuring atmospheric levels
of methane, carbon dioxide, and water vapor, Appl. Phys. B, 92, 403–408,
2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Drinovec, L., Mocnik, G., Zotter, P., Prevot, A. S. H., Ruckstuhl, C., Coz,
E., Rupakheti, M., Sciare, J., Muller, T., Wiedensohler, A., and Hansen, A.
D. A: The Dual Spot Aethalometer: An improved measurement of aerosol black
carbon with real-time loading compensation, Atmos. Meas. Tech., 8,
1965–1979, <a href="https://doi.org/10.5194/amt-8-1965-2015" target="_blank">https://doi.org/10.5194/amt-8-1965-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Dunlea, E. J., Herndon, S. C., Nelson, D. D., Volkamer, R. M., San Martini,
F., Sheehy, P. M., Zahniser, M. S., Shorter, J. H., Wormhoudy, J. C., Lamb,
B. K., Allwine, E. J., Gaffney, J. S., Marley, N. A., Grutter, M., Marquez,
C., Blanco, S., Cardenas, B., Retama, A., Ramos-Villegas, C. R., Kolb, C. E.,
Molina, L. T., and Molina, M. J.: Evaluation of nitrogen dioxide
chemiluminescence monitors in a polluted urban environment, Atmos. Chem.
Phys., 7, 2691–2704, <a href="https://doi.org/10.5194/acp-7-2691-2007" target="_blank">https://doi.org/10.5194/acp-7-2691-2007</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Finlayson-Pitts, B. J. and Pitts, J. N.: Chemistry of the Upper and Lower
Atmosphere: Theory, Experiments and Applications, Academic Press, San Diego,
2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Fontijn, A., Sabadell, A. J., and Ronco, R. J.: Homogenous chemiluminescent
measurement of nitric oxide with ozone, Anal. Chem., 42, 575–579, 1970.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Haagen-Smit, A. J. and Fox, M. M.: Photochemical ozone formation with
hydrocarbons and automobile exhaust, J. Air Pollut. Control Assoc., 4,
105–108, 1954.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Hansen, A. D. A., Rosen, H., and Novakov, T.: Real-time measurement of the
aerosol absorption-coefficient of aerosol particles, Appl. Opt., 21,
3060–3062, 1982.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Herriott, D. and Schulte, H.: Folded optical delay lines, Appl. Opt., 4,
883–889, 1965.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Kebabian, P. L., Herndon, S. C., and Freedman, A.: Detection of nitrogen
dioxide by cavity attenuated phase shift spectroscopy, Anal. Chem., 77,
724–728, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Kebabian, P. L., Wood, E. C., Herndon, S. C., and Freedman, A.: A practical
alternative to chemiluminescence-based detection of nitrogen dioxide: Cavity
attenuated phase shift spectroscopy, Environ. Sci. Tech., 42, 6040–6045,
2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Keller-Rudek, H., Moortgat, G. K., Sander, R., and Sörensen, R.: The
MPI-Mainz UV/VIS spectral atlas of gaseous molecules of atmospheric interest,
Earth Syst. Sci. Data, 5, 365–373, <a href="https://doi.org/10.5194/essd-5-365-2013" target="_blank">https://doi.org/10.5194/essd-5-365-2013</a>,
2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Massoli, P., Kebabian, P. L., Onasch, T. B., Hills, F. B., and Freedman, A.:
Aerosol light extinction measurements by Cavity Attenuated Phase Shift (CAPS)
Spectroscopy: Laboratory validation and field deployment of a compact aerosol
particle extinction monitor, Aerosol Sci. Technol., 44, 428–435, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Moosmüller, H., Varma, R., and Arnott, W. P.: Cavity ring-down and
cavity-enhanced detection techniques for the measurement of aerosol
extinction, Aerosol Sci. Technol., 39, 30–39, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Paldus, B. A. and Kachanov, A. A.: Spectroscopic techniques: Cavity-enhanced
methods, in: Atomic, Molecular, and Optical Physics Handbook, Part C:
Molecules, edited by: Drake, G. W. F., Springer, Berlin, 621–640, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Parrish, D. D. and Fehsenfeld, F. C.: Methods for gas-phase measurements of
ozone, ozone precursors and aerosol precursors, Atmos. Environ., 34,
1921–1957, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Parrish, D. D., Hahn, C. H., Fahey, D. W., Williams, E. J., Bollinger, M. J.,
Hübler, G., Buhr, M. P., Murphy, P. C., Trainer, M., Hsie, E. Y., Liu, S.
C., and Fehsenfeld, F. C.: Systematic variations in the concentration of
NO<sub><i>x</i></sub>(NO plus NO<sub>2</sub>) at Niwot Ridge, Colorado, J. Geophys. Res., 95,
1817–1836, 1990.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Platt, U.: Differential optical absorption spectroscopy (DOAS), Chem. Anal.
Series, 127, 27–83, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Schiff, H. I., Karecki, D. R., Harris, G. W., Hastie, E. R., and MacKay, G.
I.: A tunable diode laser system for aircraft measurements of trace gases, J.
Geophys. Res., 95, 147–153, 1990.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Schnaiter, M., Schmid, O., Petzold, A., Fritzsche, L., Klein, K. F., Andreae,
M. O., Helas, G., Thielmann, A., Gimmler, M., Möhler, O., Linke, C., and
Schurath, U.: Measurement of wavelength-resolved light absorption by aerosols
utilizing a UV-VIS extinction cell, Aerosol Sci. Technol., 39, 249–260,
2005.

</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Schwarz, F. P., Okabe, H., and Whittaker, J. K.: Fluorescence detection of
sulfur dioxide in air at the parts per billion level, Anal. Chem., 46,
1024–1028, 1974.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Stutz, J., Alicke, B., Ackermann, R., Geyer, A., Wang, S., White, A. B.,
Williams, E. J., Spicer, C. W., and Fast, D.: Relative humidity dependence of
HONO chemistry in urban areas, J. Geophys. Res., 109, D03307,
<a href="https://doi.org/10.1029/2003JD004135" target="_blank">https://doi.org/10.1029/2003JD004135</a>,2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Thornton, J. A., Wooldridge, P. J., and Cohen, R. C.: Atmospheric NO2: In
situ laser-induced fluorescence detection at parts per trillion mixing
ratios, Anal. Chem., 72, 528–539, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Turnipseed, A. A., Andersen, P. C., Williford, C. J., Ennis, C. A., and
Birks, J. W.: Use of a heated graphite scrubber as a means of reducing
interferences in UV-absorbance measurements of atmospheric ozone, Atmos.
Meas. Tech., 10, 2253–2269, <a href="https://doi.org/10.5194/amt-10-2253-2017" target="_blank">https://doi.org/10.5194/amt-10-2253-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
US-EPA: Report to the Congress on Black Carbon, Department of the Interior,
Environment and Related Agencies, 351 pp., 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Vandaele, A. C., Simon, P. C., Guilmot, J. M., Carleer, M., and Colin, R.:
SO<sub>2</sub> absorption cross section measurement in the UV using a Fourier
transform spectrometer, J. Geophys. Res., 99, 25599–25605, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
Villena, G. Bejan, I., Kurtenback, R., Wiesen, P., and Kleffmann, J.:
Interferences of commercial NO<sub>2</sub> instruments in the urban atmosphere
and in a smog chamber, Atmos. Meas. Tech., 5, 149–159,
<a href="https://doi.org/10.5194/amt-5-149-2012" target="_blank">https://doi.org/10.5194/amt-5-149-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Vrekoussis, M., Wittrock, F., Richter, A., and Burrows, J. P.: Temporal and
spatial variability of glyoxal as observed from space, Atmos. Chem. Phys., 9,
4485–4504, <a href="https://doi.org/10.5194/acp-9-4485-2009" target="_blank">https://doi.org/10.5194/acp-9-4485-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Washenfelder, R. A., Flores, J. M., Brock, C. A., Brown, S. S., and Rudich,
Y.: Broadband measurements of aerosols extinction in the ultraviolet spectral
region, Atmos. Meas. Tech., 6, 861–877,
<a href="https://doi.org/10.5194/amt-6-861-2013" target="_blank">https://doi.org/10.5194/amt-6-861-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Weingartner, E., Saathoff, H., Schnaiter, M., Streit, N., Bitnar, B., and
Baltensperger, U.: Absorption of light by soot particles: Determination of
the absorption coefficients by means of aethalometers, J. Aerosol Sci., 34,
1445–1463, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
White, J. U.: Long optical paths of large aperture, J. Opt. Soc. Am., 32,
285–288, 1942.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Wilson, K. L. and Birks, J. W.: Mechanism and elimination of a water vapor
interference in the measurement of ozone by UV absorbance, Environ. Sci.
Technol., 40, 6361–6367, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Winer, A. M., Peters, J. W., Smith, J. P., and Pitts, J. N.: Response of
commercial chemiluminescent NO-NO<sub>2</sub> analyzers to other
nitrogen-containing compounds, Environ. Sci. Technol., 8, 1118–1121, 1974.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
World Health Organization: Burden of disease from Household Air Pollution for
2012,
<a href="http://www.who.int/entity/phe/health_topics/outdoorair/databases/FINAL_HAP_AAP_BoD_24March2014.pdf?ua={1}" target="_blank">http://www.who.int/entity/phe/health_topics/outdoorair/databases/FINAL_HAP_AAP_BoD_24March2014.pdf?ua={1}</a>,
last access: December 2017, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Zhao, W., Xu, X., Dong, M., Chen, W., Gu, X., Hu, C., Huang, Y., Gao, X.,
Huang, W., and Zhang, W.: Development of a cavity-enhanced aerosol
albedometer, Atmos. Meas. Tech., 7, 2551–2566,
<a href="https://doi.org/10.5194/amt-7-2551-2014" target="_blank">https://doi.org/10.5194/amt-7-2551-2014</a>, 2014.
</mixed-citation></ref-html>--></article>
