<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-11-4605-2018</article-id><title-group><article-title>Long-term evaluation of air sensor technology under ambient conditions in
Denver, Colorado</article-title><alt-title>Long-term evaluation of air sensor technology</alt-title>
      </title-group><?xmltex \runningtitle{Long-term evaluation of air sensor technology}?><?xmltex \runningauthor{S. Feinberg et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1 aff2">
          <name><surname>Feinberg</surname><given-names>Stephen</given-names></name>
          <email>feinberg.stephen@epa.gov</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Williams</surname><given-names>Ron</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Hagler</surname><given-names>Gayle S. W.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Rickard</surname><given-names>Joshua</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Brown</surname><given-names>Ryan</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Garver</surname><given-names>Daniel</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Harshfield</surname><given-names>Greg</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Stauffer</surname><given-names>Phillip</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Mattson</surname><given-names>Erick</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Judge</surname><given-names>Robert</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Garvey</surname><given-names>Sam</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Oak Ridge Institute for Science and Education, Oak Ridge, TN 37830, USA</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>U.S. Environmental Protection Agency (EPA), Office of Research and
Development, <?xmltex \hack{\break}?>Research Triangle Park, NC 27711, USA</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>U.S. EPA Region 8, Denver, CO 80202, USA</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>U.S. EPA Region 4, Atlanta, GA 30303, USA</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>State of Colorado Department of Public Health and Environment (CDPHE), Denver, CO, USA</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>U.S. EPA Region 1, Boston, MA 02109, USA</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>Jacobs Technology, Inc, Research Triangle Park, NC 27709, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Stephen Feinberg  (feinberg.stephen@epa.gov)</corresp></author-notes><pub-date><day>8</day><month>August</month><year>2018</year></pub-date>
      
      <volume>11</volume>
      <issue>8</issue>
      <fpage>4605</fpage><lpage>4615</lpage>
      <history>
        <date date-type="received"><day>10</day><month>January</month><year>2018</year></date>
           <date date-type="rev-request"><day>8</day><month>February</month><year>2018</year></date>
           <date date-type="rev-recd"><day>28</day><month>June</month><year>2018</year></date>
           <date date-type="accepted"><day>19</day><month>July</month><year>2018</year></date>
      </history>
      <permissions>
        
        
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018.html">This article is available from https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018.pdf</self-uri>
      <abstract>
    <p id="d1e215">Air pollution sensors are quickly proliferating for use in a wide variety of
applications, with a low price point that supports use in high-density
networks, citizen science, and individual consumer use. This emerging
technology motivates the assessment under real-world conditions, including
varying pollution levels and environmental conditions. A seven-month,
systematic field evaluation of low-cost air pollution sensors was performed
in Denver, Colorado, over 2015–2016; the location was chosen to evaluate the
sensors in a high-altitude, cool, and dry climate. A suite of particulate
matter (PM), ozone (<inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), and nitrogen dioxide (<inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) sensors were
deployed in triplicate and were collocated with federal equivalent method
(FEM) monitors at an urban regulatory site. Sensors were evaluated for their
data completeness, correlation with reference monitors, and ability to
reproduce trends in pollution data, such as daily concentration values and
wind-direction patterns. Most sensors showed high data completeness when data
loggers were functioning properly. The sensors displayed a range of
correlations with reference instruments, from poor to very high (e.g.,
hourly-average PM Pearson correlations with reference measurements varied
from 0.01 to 0.86). Some sensors showed a change in response to laboratory
audits/testing from before the sampling campaign to afterwards, such as
Aeroqual, where the <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> response slope changed from about 1.2 to 0.6.
Some PM sensors measured wind-direction and time-of-day trends similar to
those measured by reference monitors, while others did not. This study showed
different results for sensor performance than previous studies performed by
the U.S. EPA and others, which could be due to different geographic location,
meteorology, and aerosol properties. These results imply that continued field
testing is necessary to understand emerging air sensing technology.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p id="d1e258">Next-generation air monitoring (NGAM) is a quickly evolving and expanding
field. Low-cost air pollution sensors have improved the access for both
citizens and researchers to obtain pollutant concentration data in more
locations. Many new sensors are now sold and marketed to consumers and come
with messaging on implications for health. In addition to improving the
accessibility of measurement data, air pollution sensors have been used to
supplement ambient air monitoring by providing measurements with high
spatial density and high time resolution (Mead et al., 2013; Snyder et al., 2013;
Kaufman et al., 2017). Low-cost air pollution sensors have the potential to
be important enablers of smart cities and the Internet of things (IoT),
especially in terms of forecasting<?pagebreak page4606?> and health messaging in megacities with
significant variability in microenvironments (Mead et al., 2013; Kumar et
al., 2015; Ramaswami et al, 2016). Sensors also enable new techniques for
mobile monitoring (McKercher and Vanos, 2018; Woodall et al., 2017).
However, without a proper understanding of sensor data quality and
calibration, low-cost sensors have the potential to mislead interested
community and research groups (Rai et al., 2017). Evaluating how well these
sensors perform in both laboratory and field environments is critical for
understanding their possible uses in research, citizen science, and consumer
use, for individual exposure assessment.</p>
      <p id="d1e261">Low-cost air pollution sensors, with purchase prices ranging from the low
hundreds to the low thousands of dollars per pollutant, have been developed
for both particulate and gas-phase pollutants, including ozone (<inline-formula><mml:math id="M4" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and
nitrogen dioxide (<inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). Particulate matter (PM) sensors typically
measure particle counts using light scattering principles. By using light
scattering to measure an ensemble of particles, sensors can be produced that
are miniaturized, have a lower cost, and provide real-time data. However, this
detection approach can result in bias and inaccuracy from measurement
artifacts (Gao et al., 2015; Holstius et al., 2014). Some sensors, such as
the OPC-N2 (AlphaSense), measure single particles and allocate them into size
bins. This approach is subject to measurement artifacts due to humidity
effects and potential particle coincidence, and it assumes particles are spherical
and of a homogenous density (Mukherjee et al., 2017). Gas-phase sensors
produce a signal through the reaction of the target gases with
electrochemical or metal oxide sensors. However, the reactive agents used in
these types of sensors may degrade over time, and measurement artifacts may
also exist, such as cross-interferences and impacts of temperature (Rai et
al., 2017). Therefore, it is necessary to evaluate sensor performance in
long-term, real-world study conditions (Lewis and Edwards,
2016; Williams et al., 2014).</p>
      <p id="d1e286">The evaluation of low-cost air pollution sensors and their performance is
continually evolving (McKercher et al., 2017). Many sensors are evaluated
in laboratory settings by exposure to known concentrations of gases and PM,
with PM often being evaluated by well-defined aerosols, such as polystyrene
latex, in controlled conditions (Wang et al., 2015; Lewis et al., 2016;
Manikonda et al., 2016). In outdoor field settings, sensors are often
evaluated to determine their performance in comparison with reference
methods (Borrego et al., 2016; Jiao et al., 2017; Crilley et al., 2018;
Mukherjee et al., 2017; Hagan et al., 2018). Correlations of low-cost sensors
have been found to vary from study to study, spanning from negligible to
high correlations. Recent studies have shown the correlation between sensors
and reference measurements can be improved by the application of correction
factors for environmental conditions such as relative humidity (Crilley et
al., 2018) or multivariate models and machine learning (Cross et al., 2017;
Zimmerman et al, 2018; Hagan et al., 2018).</p>
      <p id="d1e289">There are relatively few efforts that exist to systematically examine air
pollution sensor technology performance that test a variety of replicate
sensor types against reference monitors in a real-world environment. In the
United States, the U.S. EPA and the South Coast Air Quality Management
District (SCAQMD) have developed field- and laboratory-testing programs for
both gas and particulate matter sensors. These efforts represent specific
geographic locations and concentration ranges (U.S. EPA, 2017; SCAQMD, 2017).
For example, EPA's Community Air Sensor Network (CAIRSENSE) project tested a
variety of gas-phase and particulate-matter sensors in Atlanta, Georgia, under
conditions that were high temperature, high humidity, and fairly low ambient
concentrations (e.g., hourly PM<inline-formula><mml:math id="M6" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> ranging 0 to
40 <inline-formula><mml:math id="M7" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M8" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) (Jiao et al., 2016). The
SCAQMD AQ-SPEC program similarly conducts field testing of sensor technology
in Diamond Bar, California, at a near-road location approximately two months.
Evaluation of identical sensors by the EPA and SCAQMD has revealed that the
sensor performance may vary by geographical region. For example, Jiao et al. (2016) found AirBeam sensor correlations to be moderate (<inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:msup><mml:mi>r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0.43</mml:mn></mml:mrow></mml:math></inline-formula>), while SCAQMD (2017) reported much stronger correlations (<inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:msup><mml:mi>r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0.74</mml:mn></mml:mrow></mml:math></inline-formula>). This might be a result of both different concentration ranges as
well as the optical properties of the aerosol being measured.</p>
      <p id="d1e351">The Community Air Sensor Network (CAIRSENSE) project was a multi-year,
multi-location project that focused on evaluating performance
characteristics and limitations of low-cost sensors. A prior CAIRSENSE
study in Atlanta, Georgia, was conducted in 2014 and early 2015 (Jiao et
al., 2016). Atlanta was chosen to test the sensors' performance in the face
of higher temperatures and humidity. For the second part of the CAIRSENSE
study, Denver, Colorado, was chosen to test the sensors' performance under
conditions of high altitude, dryness, and lower temperature. Beyond
assessing sensor performance through correlation with a reference monitor,
this study also investigates the degree to which data from sensors are able
to produce similar temporal, wind-direction, and transient-event trends in
comparison to high-time-resolution reference monitors.</p>
</sec>
<sec id="Ch1.S2">
  <title>Methods</title>
      <p id="d1e360">Sensors for this study were selected based on cost, commercial availability,
market prevalence, capability, and applicability to EPA research objectives.
Table 1 lists the sensors chosen for this study, pollutants measured by each
sensor, and the measurement principle used by each sensor. Cost information
for these sensors can be found on the EPA's Air Sensor Toolbox (U.S. EPA,
2017). Two different Dylos units were used for this study. Unit 1 was a
Dylos DC1100, while units 2 and 3 were Dylos DC1100 Pro models, where the
Pro models are advertised to have increased sensitivity for smaller
particles. The Shinyei, Dylos, AirBeam, Aeroqual,<?pagebreak page4607?> and CairClip sensors were
used in both the Denver and Atlanta studies (Jiao et al., 2016).
Additionally, several of these sensors have been evaluated in laboratory or
short-term ambient settings (e.g., Air Sensor Toolbox reference; Sousan et al.,
2016; SCAQMD 2017).</p>
      <p id="d1e363">Air pollution sensors were acquired and deployed in triplicate. Before
deployment, laboratory sensor response audits were performed for all of the
available sensors. PM sensors were zero-checked in a clean room environment,
all reporting &lt; 2 <inline-formula><mml:math id="M11" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M12" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> values under those conditions,
except for the AirAssure. The software for the AirAssure performs its own
zeroing; therefore, they were operated “as is”. A pre-deployment sensor
response audit was not performed for the TZOA as it was received shortly
before deployment. Sensor output was not adjusted based on the calibration
audits in order to reflect
their “out of the box” performance. Sensor responses were also audited by
either recording their responses to known concentrations (Aeroqual and
CairClip sensors) or in a clean air environment (PM sensors) after the end
of the measurement period, to evaluate possible sensor drift. Laboratory
audit results are presented in the Supplement.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><caption><p id="d1e388">Sensors used during the CAIRSENSE – Denver study.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Sensor</oasis:entry>
         <oasis:entry colname="col2">Pollutant(s)</oasis:entry>
         <oasis:entry colname="col3">Principle of</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">measured</oasis:entry>
         <oasis:entry colname="col3">operation</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Aeroqual SM-50</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M13" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Electrochemical sensor</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TSI AirAssure</oasis:entry>
         <oasis:entry colname="col2">PM</oasis:entry>
         <oasis:entry colname="col3">Light scattering</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AirCasting AirBeam</oasis:entry>
         <oasis:entry colname="col2">PM</oasis:entry>
         <oasis:entry colname="col3">Light scattering</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Cairpol CairClip</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M14" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Electrochemical sensor</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Dylos DC1100/</oasis:entry>
         <oasis:entry colname="col2">PM</oasis:entry>
         <oasis:entry colname="col3">Laser particle counter</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">DC1100 Pro</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AlphaSense OPC-N2</oasis:entry>
         <oasis:entry colname="col2">PM</oasis:entry>
         <oasis:entry colname="col3">Laser particle counter</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Shinyei PMS-SYS-1</oasis:entry>
         <oasis:entry colname="col2">PM</oasis:entry>
         <oasis:entry colname="col3">Light scattering</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AirViz Speck</oasis:entry>
         <oasis:entry colname="col2">PM</oasis:entry>
         <oasis:entry colname="col3">Light scattering</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TZOA PM Research</oasis:entry>
         <oasis:entry colname="col2">PM</oasis:entry>
         <oasis:entry colname="col3">Laser particle counter</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Sensor</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e585">Sensors were deployed at the downtown Denver Continuous Ambient Monitoring
Program (CAMP) regulatory monitoring site (latitude: 39.751184; longitude:
<inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">104.987625</mml:mn></mml:mrow></mml:math></inline-formula>) from September 2015 to March 2016. The CAMP site was operated
by the state of Colorado for the duration of the study. Sensors were placed
in a ventilated, multi-level shelter designed to allow ambient air
circulation and prevent intrusion from precipitation, as shown in Fig. 1.
A full description of the shelter has been previously reported (Jiao et al., 2016).
The sensors were connected to data loggers stored in weatherproof enclosures
attached to the bottom of the shelter. Most of the sensors were connected to
Arduino (single-board) microprocessors with either Ethernet (IEEE 802.3
standard) or Recommended Standard 232 (RS-232) serial communication cables.
The OPC-N2 and Speck sensor data were logged using laptops, and the TZOA
data were stored internally on secure digital (SD) cards. To comply with EPA
data security requirements, the cloud based storage capability of the AirAssure
sensors was disabled, and these units reported data locally via the
Arduino microprocessors with onboard memory. The CairClip sensor measures
the combined signal from <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Therefore, both <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements from the CairClip were determined by
subtracting the opposite (collocated) reference measurement. The Dylos units
also measure multiple particle size fractions. In this study, the “small”
particle size fraction, as described by the manufacturer, was used for
PM<inline-formula><mml:math id="M20" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> comparisons. TZOA sensors did not have a real-time
clock and only measured time as the elapsed number of milliseconds since
the device was powered on. Therefore, field operators were required to
accurately record start and end times as a means of establishing the sensor
response time series.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><caption><p id="d1e655">Sensor deployment shelter.</p></caption>
        <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018-f01.png"/>

      </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><caption><p id="d1e667">Sensor data completeness.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Sensor</oasis:entry>
         <oasis:entry colname="col2">Measurement %</oasis:entry>
         <oasis:entry colname="col3">Sensor on and</oasis:entry>
         <oasis:entry colname="col4">Completely</oasis:entry>
         <oasis:entry colname="col5">Comments</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">not logging %</oasis:entry>
         <oasis:entry colname="col4">missing %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Aeroqual</oasis:entry>
         <oasis:entry colname="col2">82 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">18 %</oasis:entry>
         <oasis:entry colname="col5">45 % of logged values were 0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">73 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">27 %</oasis:entry>
         <oasis:entry colname="col5">42 % of logged values were 0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">81 %</oasis:entry>
         <oasis:entry colname="col3">5 %</oasis:entry>
         <oasis:entry colname="col4">13 %</oasis:entry>
         <oasis:entry colname="col5">32 % of logged values were 0</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">87 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">13 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AirAssure</oasis:entry>
         <oasis:entry colname="col2">87 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">13 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">87 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">13 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">74 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">25 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AirBeam</oasis:entry>
         <oasis:entry colname="col2">62 %</oasis:entry>
         <oasis:entry colname="col3">6 %</oasis:entry>
         <oasis:entry colname="col4">32 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">62 %</oasis:entry>
         <oasis:entry colname="col3">6 %</oasis:entry>
         <oasis:entry colname="col4">32 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">29 %</oasis:entry>
         <oasis:entry colname="col3">53 %</oasis:entry>
         <oasis:entry colname="col4">18 %</oasis:entry>
         <oasis:entry colname="col5">56 % of logged values were 255<inline-formula><mml:math id="M22" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CairClip</oasis:entry>
         <oasis:entry colname="col2">63 %</oasis:entry>
         <oasis:entry colname="col3">13 %</oasis:entry>
         <oasis:entry colname="col4">24 %</oasis:entry>
         <oasis:entry colname="col5">No data before 10 Aug 2015</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">63 %</oasis:entry>
         <oasis:entry colname="col3">23 %</oasis:entry>
         <oasis:entry colname="col4">13 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">82 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">18 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Dylos</oasis:entry>
         <oasis:entry colname="col2">82 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">18 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">72 %</oasis:entry>
         <oasis:entry colname="col3">1 %</oasis:entry>
         <oasis:entry colname="col4">27 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">77 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">23 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">OPC-N2</oasis:entry>
         <oasis:entry colname="col2">76 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">24 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">71 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">29 %</oasis:entry>
         <oasis:entry colname="col5">59 % of logged values were 0</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">82 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">18 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Shinyei</oasis:entry>
         <oasis:entry colname="col2">73 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">27 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">87 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">13 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">92 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">8 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Speck</oasis:entry>
         <oasis:entry colname="col2">93 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">7 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">96 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">4 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">61 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">39 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TZOA</oasis:entry>
         <oasis:entry colname="col2">47 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">53 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">47 %</oasis:entry>
         <oasis:entry colname="col3">0 %</oasis:entry>
         <oasis:entry colname="col4">53 %</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e670"><inline-formula><mml:math id="M21" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> 255 represented a communication or other unknown sensor failure.</p></table-wrap-foot></table-wrap>

      <p id="d1e1195">A total of four Arduino microprocessors and three laptops were used
simultaneously for data logging. Between the data loggers, laptops and
onboard data storage, there were many different sensor data output formats.
Separate data scripts were developed to process each different data format
into similarly formatted files for each air pollution sensor type. Once data
collections were initiated in September 2015, the sensors were operated with
little or no intervention through the entirety of the study. Noted
interventions included restarting data systems when they “locked up” or
removing snow from the shelves housing the sensors during a major winter
snowstorm.</p>
      <p id="d1e1198">Federal equivalent method (FEM) measurements at the Denver monitoring site
were collected using a Teledyne 400E <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> monitor, Teledyne 200EU
<inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> analyzer, and a GRIMM EDM 180 dust monitor, which measured
PM<inline-formula><mml:math id="M25" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> and PM<inline-formula><mml:math id="M26" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10<?pagebreak page4608?></mml:mn></mml:msub></mml:math></inline-formula> mass at 1 min intervals using optical
detection. All sensors and monitors collected pollutant data at 1 min
intervals or less. One-minute values were used to generate concentrations at
multiple time intervals, with primarily 1 h averages used for data
analysis. All averaging and other data processing was performed using the
following software: RStudio version 0.98.1103, R version 3.2.2, and the
ggplot2, scales, plyr, lattice, corrplot, and “data.table” (extension of
“data.frame”) packages.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><caption><p id="d1e1244">Regression and precision results for CAIRSENSE sensors (1 h time averaged).</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.90}[.90]?><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Sensor</oasis:entry>
         <oasis:entry colname="col2">Pollutant</oasis:entry>
         <oasis:entry colname="col3">Reference</oasis:entry>
         <oasis:entry colname="col4">Slope</oasis:entry>
         <oasis:entry colname="col5">Intercept</oasis:entry>
         <oasis:entry colname="col6">Pearson</oasis:entry>
         <oasis:entry colname="col7">rms</oasis:entry>
         <oasis:entry colname="col8">Number of</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">average</oasis:entry>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6">correlation,</oasis:entry>
         <oasis:entry colname="col7">precision</oasis:entry>
         <oasis:entry colname="col8">hourly</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">concentration<inline-formula><mml:math id="M31" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">1</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M32" display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">(%)</oasis:entry>
         <oasis:entry colname="col8">measurements</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Aeroqual SM-50</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M33" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, ppb</oasis:entry>
         <oasis:entry colname="col3">18.8 ppb</oasis:entry>
         <oasis:entry colname="col4">0.56</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.004</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.93</oasis:entry>
         <oasis:entry colname="col7">73</oasis:entry>
         <oasis:entry colname="col8">3325</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.58</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.004</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.92</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2963</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.77</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.004</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.96</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3279</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TSI AirAssure</oasis:entry>
         <oasis:entry colname="col2">PM, <inline-formula><mml:math id="M37" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M38" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">7.8 <inline-formula><mml:math id="M39" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M40" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">1.14</oasis:entry>
         <oasis:entry colname="col5">2.64</oasis:entry>
         <oasis:entry colname="col6">0.8</oasis:entry>
         <oasis:entry colname="col7">41</oasis:entry>
         <oasis:entry colname="col8">3486</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">1.13</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.78</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3486</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">1.19</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M42" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.38</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.81</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3486</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AirCasting AirBeam</oasis:entry>
         <oasis:entry colname="col2">Particle count, hundreds of</oasis:entry>
         <oasis:entry colname="col3">7.8 <inline-formula><mml:math id="M43" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M44" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">273</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">323</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.82</oasis:entry>
         <oasis:entry colname="col7">6</oasis:entry>
         <oasis:entry colname="col8">3028</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">particles per cubic foot (hppcf)</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">278</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">124</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.84</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2539</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">322</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">352</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.82</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2532</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Cairpol CairClip</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M48" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, ppb</oasis:entry>
         <oasis:entry colname="col3">18.8 ppb</oasis:entry>
         <oasis:entry colname="col4">NA<inline-formula><mml:math id="M49" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">NA<inline-formula><mml:math id="M50" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">NA<inline-formula><mml:math id="M51" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">NA<inline-formula><mml:math id="M52" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8">738</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">23.6</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2831</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">1.03</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">39.0</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.46</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2852</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Cairpol CairClip</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M57" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, ppb</oasis:entry>
         <oasis:entry colname="col3">26.8 ppb</oasis:entry>
         <oasis:entry colname="col4">NA<inline-formula><mml:math id="M58" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">NA<inline-formula><mml:math id="M59" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">NA<inline-formula><mml:math id="M60" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">NA<inline-formula><mml:math id="M61" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8">738</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.65</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.87</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2831</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.67</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">15</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.84</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2852</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Dylos DC1100/DC1100 Pro</oasis:entry>
         <oasis:entry colname="col2">“Small” particle count, hppcf</oasis:entry>
         <oasis:entry colname="col3">7.8 <inline-formula><mml:math id="M64" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M65" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">64</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">152</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.86</oasis:entry>
         <oasis:entry colname="col7">15</oasis:entry>
         <oasis:entry colname="col8">3324</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">428</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1182</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.78</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3324</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">431</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">941</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.73</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2937</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Dylos DC1100/DC1100 Pro</oasis:entry>
         <oasis:entry colname="col2">“Large” particle count, hppcf</oasis:entry>
         <oasis:entry colname="col3">12.0 <inline-formula><mml:math id="M69" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M70" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">1.3</oasis:entry>
         <oasis:entry colname="col5">5.5</oasis:entry>
         <oasis:entry colname="col6">0.40</oasis:entry>
         <oasis:entry colname="col7">10</oasis:entry>
         <oasis:entry colname="col8">3324</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">5.7</oasis:entry>
         <oasis:entry colname="col5">73</oasis:entry>
         <oasis:entry colname="col6">0.33</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3324</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">4.9</oasis:entry>
         <oasis:entry colname="col5">84</oasis:entry>
         <oasis:entry colname="col6">0.27</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2937</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AlphaSense OPC-N2</oasis:entry>
         <oasis:entry colname="col2">PM<inline-formula><mml:math id="M71" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>, <inline-formula><mml:math id="M72" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M73" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">7.8 <inline-formula><mml:math id="M74" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M75" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.4</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.30</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.45</oasis:entry>
         <oasis:entry colname="col7">108</oasis:entry>
         <oasis:entry colname="col8">2969</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.49</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.66</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.34</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2939</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.07</oasis:entry>
         <oasis:entry colname="col5">0.60</oasis:entry>
         <oasis:entry colname="col6">0.11</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2735</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AlphaSense OPC-N2</oasis:entry>
         <oasis:entry colname="col2">PM<inline-formula><mml:math id="M78" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula>, <inline-formula><mml:math id="M79" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M80" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">19.6 <inline-formula><mml:math id="M81" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M82" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.45</oasis:entry>
         <oasis:entry colname="col5">2.98</oasis:entry>
         <oasis:entry colname="col6">0.47</oasis:entry>
         <oasis:entry colname="col7">101</oasis:entry>
         <oasis:entry colname="col8">2969</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.54</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">0.68</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2939</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.12</oasis:entry>
         <oasis:entry colname="col5">2.86</oasis:entry>
         <oasis:entry colname="col6">0.20</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2735</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Shinyei PMS-SYS-1</oasis:entry>
         <oasis:entry colname="col2">PM<inline-formula><mml:math id="M84" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>, <inline-formula><mml:math id="M85" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M86" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">7.8 <inline-formula><mml:math id="M87" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M88" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.58</oasis:entry>
         <oasis:entry colname="col5">0.24</oasis:entry>
         <oasis:entry colname="col6">0.71</oasis:entry>
         <oasis:entry colname="col7">20</oasis:entry>
         <oasis:entry colname="col8">3325</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.54</oasis:entry>
         <oasis:entry colname="col5">0.8</oasis:entry>
         <oasis:entry colname="col6">0.72</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">2963</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.42</oasis:entry>
         <oasis:entry colname="col5">4.35</oasis:entry>
         <oasis:entry colname="col6">0.01<inline-formula><mml:math id="M89" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3486</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">AirViz Speck</oasis:entry>
         <oasis:entry colname="col2">PM<inline-formula><mml:math id="M90" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>, <inline-formula><mml:math id="M91" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M92" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">7.8 <inline-formula><mml:math id="M93" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M94" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.76</oasis:entry>
         <oasis:entry colname="col5">13</oasis:entry>
         <oasis:entry colname="col6">0.24</oasis:entry>
         <oasis:entry colname="col7">37</oasis:entry>
         <oasis:entry colname="col8">3557</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.74</oasis:entry>
         <oasis:entry colname="col5">15</oasis:entry>
         <oasis:entry colname="col6">0.40</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3584</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">0.62</oasis:entry>
         <oasis:entry colname="col5">10</oasis:entry>
         <oasis:entry colname="col6">0.35</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">3971</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TZOA PM Research Sensor</oasis:entry>
         <oasis:entry colname="col2">Particle count, hppcf</oasis:entry>
         <oasis:entry colname="col3">7.8 <inline-formula><mml:math id="M95" display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math id="M96" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">NA<inline-formula><mml:math id="M97" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">NA<inline-formula><mml:math id="M98" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">NA<inline-formula><mml:math id="M99" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">17<inline-formula><mml:math id="M100" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8">2341</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">6.68</oasis:entry>
         <oasis:entry colname="col5">1.37</oasis:entry>
         <oasis:entry colname="col6">0.66</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">1838</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">6.75</oasis:entry>
         <oasis:entry colname="col5">2.16</oasis:entry>
         <oasis:entry colname="col6">0.72</oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8">1836</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table><?xmltex \begin{scaleboxenv}{.90}[.90]?><table-wrap-foot><p id="d1e1247"><inline-formula><mml:math id="M27" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">1</mml:mn></mml:msup></mml:math></inline-formula> Average concentration calculated for hours with valid sampling data.
<inline-formula><mml:math id="M28" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> Correlation results not shown due to large amount of missing or invalid
data.
<inline-formula><mml:math id="M29" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> Shinyei unit 3's correlation improved to 0.84 when only considering
data from October 16 and later.
<inline-formula><mml:math id="M30" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula> TZOA unit 1 was excluded from rms precision calculations.</p></table-wrap-foot><?xmltex \end{scaleboxenv}?></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p id="d1e2906">Correlation (<inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>×</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula>) plot for sensors measuring fine PM. Ellipses
represent the overall scatter of the data (1 h averaged measurements).</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018-f02.png"/>

      </fig>

      <p id="d1e2927">Sensor data were recovered from the connected laptops and SD cards connected
to the data loggers. Most sensors reported data in 1 min intervals. The
AlphaSense OPC-N2 units recorded concentrations every 10 s. These
measurements were used to calculate 1 min averages. The TZOA sensors
reported data based on time elapsed from turning on each unit. The start
times for each unit and total elapsed time for each measurement were
combined to generate 5 s time stamps for the TZOA measurements. These
values were then used to calculate 1 min averages.</p>
      <p id="d1e2930">In order to best replicate actual use by non-experts and avoid biasing the
results towards a positive direction, minimal screening of data was
performed. Quality assurance screening consisted primarily of removing data
where there was a clear malfunction of the sensor, such as non-numeric data
output, or when a sensor (e.g., CairClip unit 1) became “stuck”, reporting a
repeated value (value <inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mn mathvariant="normal">255</mml:mn></mml:mrow></mml:math></inline-formula>) for long time spans. These types of errors
had previously been identified for the output of this sensor type. The
Aeroqual units had significant numbers of measurements that, for some
reason, were reported as zero. These were possibly due to the inability of
the sensor to detect trace concentrations and were therefore not screened
out of the data.</p>
      <p id="d1e2943">Timestamps for all sensors except the TZOA were recorded in Mountain
Standard Time. As previously<?pagebreak page4609?> mentioned, TZOA timestamps were generated by
combining the initial recording time and the elapsed time reported by the
sensors. One-minute measurements and averages were used to calculate
5 min and hourly averages. Hourly averages were further used to calculate
12 h and daily averages. FEM measurements from the state of Colorado
instruments were also recorded at 1 min intervals and averaged in the
same manner as the sensor data. Data from all sensors and reference
instruments were stored in separate data files and combined based on
timestamps for analyses using R scripts.</p>
      <?pagebreak page4610?><p id="d1e2946">Sensors were also investigated for how well they replicated different trends
in the regulatory monitor measurement data. The trends analyzed included
average sensor responses based on time of day and wind direction. In order
to evaluate these trends, different normalized sensor responses were used.
The normalized average sensor response for the diel (daily, 24 h)
patterns was calculated as the average concentration for a given hour
divided by the average concentration for the hour beginning at 12:00. The
normalized average sensor response for wind direction data was defined as
the mean concentration for each 10<inline-formula><mml:math id="M103" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> wind “bin”, divided by the average
concentration of the 170 to 180<inline-formula><mml:math id="M104" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> bin. The sensor response times were
also analyzed by calculating the average 1 min relative sensor
response, as defined by the distribution of the 1 min concentration
differences divided by the average sensor response.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3" specific-use="star"><caption><p id="d1e2970">OPC-N2 PM<inline-formula><mml:math id="M105" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> and relative humidity <bold>(a)</bold> and hourly average
FEM PM<inline-formula><mml:math id="M106" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> concentration and AirBeam particle count stratified by relative
humidity <bold>(b)</bold>.</p></caption>
        <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018-f03.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><caption><p id="d1e3005">Diel patterns for <bold>(a)</bold> PM<inline-formula><mml:math id="M107" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> and <bold>(b)</bold> <inline-formula><mml:math id="M108" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor and reference
measurements.</p></caption>
        <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018-f04.png"/>

      </fig>

</sec>
<sec id="Ch1.S3">
  <title>Results and discussion</title>
      <p id="d1e3046">Table 2 shows a summary of data completeness from the air pollution sensors,
including the total percentage of minutes measured, percentage of
measurements missed by not logging data, and the percentage of completely
missing data. The majority of missing data was due to events where the
sensor and data loggers were inoperative. The most significant of these
events was due to snow intrusion into the monitoring platform in December
2015, which caused units to shut down. Most sensors had a very high data
capture rate throughout the study when the units were on (and operational).
The CairClip units had significant amounts of missing data, likely due to
data transmission errors from the universal asynchronous
receiver-transmitter (UART) serial communication system. In the previous
Atlanta study as well as in a Newark-based citizen science study (Kaufman et
al., 2017), CairClip units with identical sensors but different universal
serial bus (USB) data connections were used and did not have significant
amounts of missing data.</p>
      <p id="d1e3049">Measurements from air pollution sensors and regulatory monitors were
time-averaged at multiple intervals for comparison. The time intervals
included 5 min, hourly, 12 h, and daily averages. For each set of time
averaging, regressions were calculated to evaluate sensor correlation and
bias when compared to regulatory measurements. Additionally,
intercomparisons were made between sensors of the same pollutant type (e.g.,
correlations between PM sensors). Table 3 displays a summary of regression
statistics for sensors when compared to regulatory measurements as well as
precision calculations for 1 h time averages. The precision was
calculated as the root mean square (rms) of the hourly coefficients of
variation. In general, correlations were greatest at the 1 h time
average. Correlations in general improved slightly with increasing length of
the averaging period up to hourly averages. Reduced correlations for most
sensors at the 12 h and daily averages may be a result of a lower number
of data points. In contrast to most other measurements, sensors that
reported data for coarse PM (Dylos) or PM<inline-formula><mml:math id="M109" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula> (OPC-N2) showed improved
correlations with increasing averaging time for those measurements. The
correlations for all the time averaging periods can be found in the
Supplement. Sensors that measured particle count had better
precision than those measuring particle mass concentrations. Figure 2 shows
a Pearson correlation (<inline-formula><mml:math id="M110" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula>) plot for 1 h average reference (SoC) and PM
sensor measurements. The PM units show high correlation among sensors of the
same model, except for when one sensor in a group had significant issues. Of
the PM<inline-formula><mml:math id="M111" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> sensors, the AirAssure, AirBeam, and Dylos (<inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.73</mml:mn></mml:mrow></mml:math></inline-formula> to
0.86) units exhibited the highest correlation with reference measurements.
Dylos unit 1 had the highest linearity; however, it had the lowest particle
count response, both of which are likely explained by not detecting the
smallest particles as effectively as other units. CairClip unit 1 rarely
properly transmitted data throughout the study, leading to its low
correlations. CairClip units 2 and 3 had more sporadic data transmission
issues. All CairClip units recovered data properly once returned to the lab
after the field campaign where their internal data storage was used. The
response from Shinyei unit 3 changed in mid-October. The correlation between the unit and the reference monitor was
initially 0.01, then increased to 0.84 when comparing only the data starting
October 16 and later.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><caption><p id="d1e3091">Wind direction patterns for <bold>(a)</bold> PM<inline-formula><mml:math id="M113" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> and <bold>(b)</bold> <inline-formula><mml:math id="M114" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor and
reference measurements.</p></caption>
        <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018-f05.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><caption><p id="d1e3129">Cumulative distribution functions for 1 min response differences
for <bold>(a)</bold> PM<inline-formula><mml:math id="M115" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> and <bold>(b)</bold> <inline-formula><mml:math id="M116" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor and reference measurements.</p></caption>
        <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/11/4605/2018/amt-11-4605-2018-f06.png"/>

      </fig>

      <p id="d1e3164">Several sensor models were used in both the Atlanta and Denver CAIRSENSE
evaluation campaigns. Both studies deployed the AirBeam, Dylos, and Shinyei
PM sensors. In all cases except for Shinyei unit 3, these sensors showed
greater linearity in Denver than in Atlanta, when comparing 12 h
averages. When only considering data after October 16, Shinyei unit 3 also
had higher correlation in Denver than in Atlanta. This may be due to less
noise caused by lower humidity in Denver than in Atlanta. Aeroqual and
CairClip air pollution sensors were also deployed in both Atlanta and
Denver. <inline-formula><mml:math id="M117" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measured by the Aeroqual units showed similar correlations
in both locations (<inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.82</mml:mn></mml:mrow></mml:math></inline-formula> to 0.94 in Atlanta, <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.85</mml:mn></mml:mrow></mml:math></inline-formula> to
0.92 in Denver). <inline-formula><mml:math id="M120" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measured by CairClip units 2 and 3 in Denver showed
poorer correlations than the CairClip units used in Atlanta (<inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula> to 0.21 in Denver versus <inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 0.68 to 0.88 in Atlanta). However,
<inline-formula><mml:math id="M123" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measured by<?pagebreak page4611?> CairClip units 2 and 3 in Denver was more highly
correlated than in Atlanta (<inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.71</mml:mn></mml:mrow></mml:math></inline-formula> to 0.76 in Denver versus 0.57
in Atlanta).</p>
      <p id="d1e3274">While Denver is not necessarily known for high humidity, humidity artifacts
were observed in some sensors. Figure 3a shows the PM<inline-formula><mml:math id="M125" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> concentrations
measured by one of the OPC-N2 against relative humidity. At relative humidity around
90 %, the PM concentration spikes significantly, suggesting that humidity
is interfering with the sensor response measurement. This behavior is
similar to that observed by Sousan et al. (2016). Some other instruments
also had different responses based on humidity. Figure 3b shows hourly
particle counts measured by an AirBeam sensor against PM<inline-formula><mml:math id="M126" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>
concentration measured by the reference instrument, stratified by relative
humidity. There appear to be two separate relations between reference
measured concentrations and sensor measured particle counts, with a greater
particle count response occurring more at higher humidity. This relationship
was observed in each of the AirBeam sensors. An example of humidity
relationships from each sensor type can be found in the Supplement.</p>
      <p id="d1e3295">In addition to understanding the precision of air pollution sensors and how
well they correlate with reference measurements, it is also important to
understand how well a sensor can capture trends and distributions of
pollutant concentrations. There are many ways to examine these trends and
distributions. Figure 4 shows the diel patterns of PM<inline-formula><mml:math id="M127" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> (a) and
<inline-formula><mml:math id="M128" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (b) reference and sensor measurements respectively. The results, for
each sensor, represent the measurements of the best performing unit for each
sensor type/model, as determined by <inline-formula><mml:math id="M129" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> values. The various PM air
pollution sensors<?pagebreak page4612?> have a wide range of comparisons to the reference monitor.
Two sensors (TZOA and AirBeam) show similar patterns throughout the day,
while some other sensors do not reflect the reference diel pattern at all
(e.g., OPC, Speck). It is interesting to note that both the TZOA and
AirBeam measure particle count; however, there is no basis to say why these
sensors performed better than those measuring mass concentrations. The
Aeroqual sensor diel pattern was similar to that of the reference <inline-formula><mml:math id="M130" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
monitor. The nature of the calculation of <inline-formula><mml:math id="M131" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M132" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> by
subtraction, and missing data from the CairClip sensors, prevented this
analysis from providing meaningful results.</p>
      <p id="d1e3363">Air quality measurements are also known to be dependent on wind direction,
and it is important to know whether these differences were reflected in the
sensor measurements. Figure 5 shows the normalized average sensor response
PM<inline-formula><mml:math id="M133" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> (a) and <inline-formula><mml:math id="M134" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (b) response of the sensors and the reference
monitors respectively. The reference monitor response is represented by the
black line. Both the highest concentrations and greatest variation from the
reference monitor concentrations occurred when winds were from the north,
where there are multiple large roadways and a railyard. However, there<?pagebreak page4613?> was
no other evidence to suggest that these sources contributed to differences
in the measurement trends. The sensors generally compared more favorably
with the reference monitors when examining the wind direction dependence of
concentration. This is most apparent in the OPC-N2 sensor, where the sensor
trends track the trends measured by the reference monitor. This increases
the confidence that sensors may be useful in studies that pair wind
direction with concentration to determine potential bearings or
locations of pollution sources to supplement source apportionment and
receptor modeling. It also raises questions as to why an air pollution
sensor would be able to reproduce wind direction trends but not necessarily
reproduce daily concentration measurement patterns. We undertook exploration
of this perplexing result, but we were not able to determine a clearly
identifiable cause. While relative humidity and temperature do have time-of-day variation
that is not reflected in wind direction, we were unable to use these
parameters to explain the differences between time-of-day and wind-direction
trends.</p>
      <p id="d1e3386">The high-time-resolution data collected for this study allowed for the
examination of air pollution sensor response trends compared to that of
regulatory air pollution monitors. Figure 6 shows a cumulative distribution
function (CDF) for the relative change in sensor and regulatory monitor
response between 1 min measurements for PM<inline-formula><mml:math id="M135" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> (a) and <inline-formula><mml:math id="M136" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (b)
sensor and reference measurements respectively. The relative response was
calculated as the absolute value of the difference between consecutive
1 min measurements divided by the mean measurement over the entire
study period for each sensor/monitor. If the reference monitor were
considered a perfect measurement, sensor curves to the left and above the
reference monitor line would have smaller relative changes than the reference
monitor, indicating a slower response to changes in concentration, while
curves below and to the right of the monitor line would signify larger
measurement-to-measurement changes than the reference monitor, indicating
potential high levels of measurement noise. Most PM monitors exhibited a
slower response to changes in concentration than the reference monitor. The
OPC-N2 and AirBeam sensors were the only ones with curves to the right of
the reference monitor, suggesting that they may have more noise in their
measurements. The Aeroqual sensor showed more <inline-formula><mml:math id="M137" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurement noise when
compared to the reference measurement.</p>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <title>Conclusions</title>
      <p id="d1e3426">Nine different air pollution sensor devices were deployed in triplicate with
collocated air pollution reference monitors in Denver, Colorado, over an extended
operational timeline of longer than six months. The sensors showed a wide
range of correlations with reference measurements, but they tended to have high
correlation with sensors of the same model. PM sensors deployed in both
Denver and Atlanta had higher correlations with reference monitors in Denver
than in Atlanta. This is likely due to less humidity-related response in
Denver. Aeroqual <inline-formula><mml:math id="M138" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements in Denver showed similar linearity to
those measured in Atlanta. CairClip <inline-formula><mml:math id="M139" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> correlations were lower in
Denver than in Atlanta, but <inline-formula><mml:math id="M140" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> correlations were higher. Sensors that
have also been evaluated by the South Coast Air Quality Management District
(SCAQMD) tended to show similar results in terms of correlation (SCAQMD,
2017). However, in all cases, sensors' performance in this long-term field
deployment was lower than that of laboratory-based comparisons performed in
this study and others (U.S. EPA, 2017). It is not surprising that the
results of this study for PM sensors varied from other studies, as the
responses to optical measurement techniques used by these sensors are likely
influenced by aerosol composition. This study demonstrates the need for
long-term, real-world evaluation studies for current and future air
pollution sensors, which should be performed in locations with different air
pollutant concentration ranges and aerosol characteristics.</p>
      <p id="d1e3462">Several air pollution sensors were able to capture variations in important
trends, such as diel patterns and wind direction dependence on
concentration. However, the OPC-N2 units showed similar results to reference
monitor measurement data when analyzing the wind direction trends but not
when analyzing “time-of-day” trends. These promising results show that
sensors have the possibility for supplementing measurement research
capabilities when interested in air pollution trends such as those dependent
on wind direction. Analyses of wind-direction-based air pollutant trends
could be useful for possible identification of source locations or regions,
especially with the use of a sensor-based network.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability">

      <p id="d1e3470">The CAIRSENSE dataset will be available at the EPA environmental dataset
gateway (<uri>https://edg.epa.gov</uri>) (Williams, 2018), where the dataset can
be retrieved by searching for “CAIRSENSE Denver.” Project data can also be
requested from the corresponding author.</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e3476">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-11-4605-2018-supplement" xlink:title="pdf">https://doi.org/10.5194/amt-11-4605-2018-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution">

      <p id="d1e3485">SF performed the data analysis and prepared the manuscript
with contribution from all co-authors. RW was the principal
investigator and advised data analysis and manuscript preparation. GH was co-investigator and advised data analysis and manuscript
preparation. JR, RB, DG, and RJ
provided discussion and assistance in the establishment of the study design
and execution. GH, PS, and EM carried
out day-to-day operations. SG was in charge of the establishment of
the initial site, data recovery, and principal operation of the sensors.</p>
  </notes><notes notes-type="competinginterests">

      <?pagebreak page4614?><p id="d1e3491">The authors declare that they have no conflict of
interest.</p>
  </notes><notes notes-type="disclaimer">

      <p id="d1e3497">This
article was supported by Jacobs Technology, Inc. (contract EP-C-15-008) for
the National Exposure Research Laboratory, U.S. Environmental Protection
Agency (U.S. EPA), Research Triangle Park, NC. It has been reviewed by the
U.S. EPA and approved for publication. Mention of trade names or commercial
products does not constitute endorsement or recommendation for use.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e3503">The authors would like to acknowledge the
cooperation of the Colorado Department of Public Health and Environment in
conducting this research. This project was supported in part by an
appointment to the Research Participation Program at the National Risk
Management Research Laboratory, U.S. Environmental Protection Agency,
administered by the Oak Ridge Institute for Science and Education through an
interagency agreement between the U.S. Department of Energy and EPA.
<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?> Edited by: Francis Pope<?xmltex \hack{\newline}?>
Reviewed by: two anonymous referees</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>Borrego, C., Costa, A. M., Ginja, J., Amorim, M., Coutinho, M., Karatzas,
K., Sioumis, T., Katsifarakis, N., Konstantinidis, K., De Vito, S.,
Esposito, E., Smith, P., André, N., Gérard, P., Francis, L. A.,
Castell, N., Schneider, P., Viana, M., Minguillón, M. C., Reimringer,
W., Otjes, R. P., von Sicard, O., Pohle, R., Elen, B., Suriano, D., Pfister,
V., Prato, M., Dipinto, S., and Penza, M.: Assessment of air quality
microsensors versus reference methods: The EuNetAir joint exercise,
Atmos. Environ., 147, 246–263,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2016.09.050" ext-link-type="DOI">10.1016/j.atmosenv.2016.09.050</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Crilley, L. R., Shaw, M., Pound, R., Kramer, L. J., Price, R., Young, S., Lewis, A. C., and Pope, F. D.: Evaluation of a
low-cost optical particle counter (Alphasense OPC-N2) for ambient air monitoring, Atmos. Meas. Tech., 11, 709–720,
<ext-link xlink:href="https://doi.org/10.5194/amt-11-709-2018" ext-link-type="DOI">10.5194/amt-11-709-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>Cross, E. S., Williams, L. R., Lewis, D. K., Magoon, G. R., Onasch, T. B., Kaminsky, M. L., Worsnop, D. R., and Jayne, J. T.:
Use of electrochemical sensors for measurement of air pollution: correcting interference response and validating measurements,
Atmos. Meas. Tech., 10, 3575–3588, <ext-link xlink:href="https://doi.org/10.5194/amt-10-3575-2017" ext-link-type="DOI">10.5194/amt-10-3575-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Gao, M., Cao, J., and Seto, E.: A distributed network of low-cost continuous
reading sensors to measure spatiotemporal variations of PM2.5 in Xi'an,
China, Environ. Pollut., 199, 56–65,
<ext-link xlink:href="https://doi.org/10.1016/j.envpol.2015.01.013" ext-link-type="DOI">10.1016/j.envpol.2015.01.013</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>Hagan, D. H., Isaacman-VanWertz, G., Franklin, J. P., Wallace, L. M. M., Kocar, B. D., Heald, C. L., and Kroll, J. H.:
Calibration and assessment of electrochemical air quality sensors by co-location with regulatory-grade instruments,
Atmos. Meas. Tech., 11, 315–328, <ext-link xlink:href="https://doi.org/10.5194/amt-11-315-2018" ext-link-type="DOI">10.5194/amt-11-315-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>Holstius, D. M., Pillarisetti, A., Smith, K. R., and Seto, E.: Field calibrations of a low-cost aerosol sensor at a
regulatory monitoring site in California, Atmos. Meas. Tech., 7, 1121–1131, <ext-link xlink:href="https://doi.org/10.5194/amt-7-1121-2014" ext-link-type="DOI">10.5194/amt-7-1121-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>Jiao, W., Hagler, G., Williams, R., Sharpe, R., Brown, R., Garver, D., Judge, R., Caudill, M., Rickard, J., Davis, M.,
Weinstock, L., Zimmer-Dauphinee, S., and Buckley, K.: Community Air Sensor Network (CAIRSENSE) project: evaluation of
low-cost sensor performance in a suburban environment in the southeastern United States, Atmos. Meas. Tech., 9, 5281–5292, <ext-link xlink:href="https://doi.org/10.5194/amt-9-5281-2016" ext-link-type="DOI">10.5194/amt-9-5281-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>Kaufman, A., Williams, R., Barzyk, T., Greenberg, M., O'Shea, M., Sheridan,
P., Hoang, A., Ash, C., Teitz, A., Mustafa, M., and Garvey, S.: A Citizen
Science and Government Collaboration: Developing Tools to Facilitate
Community Air Monitoring, Environmental Justice, 10, 51–61,
<ext-link xlink:href="https://doi.org/10.1089/env.2016.0044" ext-link-type="DOI">10.1089/env.2016.0044</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Kumar, P., Morawska, L., Martani, C., Biskos, G., Neophytou, M., Di
Sabatino, S., Bell, M., Norford, L., and Britter, R.: The rise of low-cost
sensing for managing air pollution in cities, Environ. Int., 75, 199–205,
2015.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>
Lewis, A. and Edwards, P.: Validate personal air-pollution sensors,
Nature, 535, 29–31, 2016.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>Lewis, A. C., Lee, J. D., Edwards, P. M., Shaw, M. D., Evans, M. J., Moller,
S. J., Smith, K. R., Buckley, J. W., Ellis, M., Gillot, S. R., and White,
A.: Evaluating the performance of low cost chemical sensors for air
pollution research, Faraday Discuss., 189, 85–103, <ext-link xlink:href="https://doi.org/10.1039/C5FD00201J" ext-link-type="DOI">10.1039/C5FD00201J</ext-link>,
2016.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Manikonda, A., Zíková, N., Hopke, P. K., and Ferro, A. R.:
Laboratory assessment of low-cost PM monitors, J. Aerosol Sci.,
102, 29–40, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2016.08.010" ext-link-type="DOI">10.1016/j.jaerosci.2016.08.010</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>McKercher, G. R. and Vanos, J. K.: Low-cost mobile air pollution monitoring
in urban environments: a pilot study in Lubbock, Texas, Environ. Technol.,
39,
1505–1514,
<ext-link xlink:href="https://doi.org/10.1080/09593330.2017.1332106" ext-link-type="DOI">10.1080/09593330.2017.1332106</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>McKercher, G. R., Salmond, J. A., and Vanos, J. K.: Characteristics and
applications of small, portable gaseous air pollution monitors,
Environ. Pollut., 223, 102–110,
<ext-link xlink:href="https://doi.org/10.1016/j.envpol.2016.12.045" ext-link-type="DOI">10.1016/j.envpol.2016.12.045</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Mead, M., Popoola, O., Stewart, G., Landshoff, P., Calleja, M., Hayes, M.,
Baldovi, J., McLeod, M., Hodgson, T., Dicks, J., Lewis, A. C., Cohen, J.,
Baron, R., Saffell, J., and Jones, R.: The use of electrochemical sensors
for monitoring urban air quality in low-cost, high-density networks, Atmos.
Environ., 70, 186–203, 2013.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>Mukherjee, A., Stanton, G. L., Graham, R. A., and Roberts, T. P.: Assessing
the Utility of Low-Cost Particulate Matter Sensors over a 12-Week Period in
the Cuyama Valley of California, Sensors, 17, 1805, <ext-link xlink:href="https://doi.org/10.3390/s17081805" ext-link-type="DOI">10.3390/s17081805</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti,
C., Yasar, A., and Rickerby, D.: End-user perspective of low-cost sensors
for outdoor air pollution monitoring, Sci. Total Environ.,
607–608, 691–705, <ext-link xlink:href="https://doi.org/10.1016/j.scitotenv.2017.06.266" ext-link-type="DOI">10.1016/j.scitotenv.2017.06.266</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>Ramaswami, A., Russell, A. G., Culligan, P. J., Sharma, K. R., and Kumar,
E.: Meta-principles for developing smart, sustainable, and healthy cities,
Science, 352, 940–943, <ext-link xlink:href="https://doi.org/10.1126/science.aaf7160" ext-link-type="DOI">10.1126/science.aaf7160</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R.
W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., and Preuss,
P. W.: The Changing Paradigm of Air<?pagebreak page4615?> Pollution Monitoring, Environ. Sci.
Technol., 47, 11369–11377, <ext-link xlink:href="https://doi.org/10.1021/es4022602" ext-link-type="DOI">10.1021/es4022602</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>Sousan, S., Koehler, K., Hallett, L., and Peters, T. M.: Evaluation of the
Alphasense Optical Particle Counter (OPC-N2) and the Grimm Portable Aerosol
Spectrometer (PAS-1.108), Aerosol Sci. Tech., 50, 1352–1365,
<ext-link xlink:href="https://doi.org/10.1080/02786826.2016.1232859" ext-link-type="DOI">10.1080/02786826.2016.1232859</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>South Coast Air Quality Management District Air Quality Sensor Performance
Evaluation Center: AQ-SPEC Home Page, available at: <uri>http://www.aqmd.gov/aq-spec</uri>, last access: 5 December
2017.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>U.S. EPA: Air Sensor Toobox, available at: <uri>https://www.epa.gov/air-sensor-toolbox</uri>,
last access: 5 December 2017.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., and Biswas, P.: Laboratory
Evaluation and Calibration of Three Low-Cost Particle Sensors for
Particulate Matter Measurement, Aerosol Sci. Tech., 49,
1063–1077, <ext-link xlink:href="https://doi.org/10.1080/02786826.2015.1100710" ext-link-type="DOI">10.1080/02786826.2015.1100710</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>Williams, R.: CAIRSENSE Denver, available at: <uri>https://edg.epa.gov</uri>, las access: 6
August
2018.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>
Williams, R., Watkins, T., and Long, R.: Low cost sensor calibration options,
Environmental Manager, 10–15, January 2014.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>Woodall, M. G., Hoover, D. M., Williams, R., Benedict, K., Harper, M., Soo,
J.-C., Jarabek, M. A., Stewart, J. M., Brown, S. J., Hulla, E. J., Caudill,
M., Clements, L. A., Kaufman, A., Parker, J. A., Keating, M., Balshaw, D.,
Garrahan, K., Burton, L., Batka, S., Limaye, S. V., Hakkinen, J. P., and
Thompson, B.: Interpreting Mobile and Handheld Air Sensor Readings in
Relation to Air Quality Standards and Health Effect Reference Values:
Tackling the Challenges, Atmosphere, 8, 182, <ext-link xlink:href="https://doi.org/10.3390/atmos8100182" ext-link-type="DOI">10.3390/atmos8100182</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>Zimmerman, N., Presto, A. A., Kumar, S. P. N., Gu, J., Hauryliuk, A., Robinson, E. S., Robinson, A. L., and R. Subramanian:
A machine learning calibration model using random forests to improve sensor performance for lower-cost air quality monitoring,
Atmos. Meas. Tech., 11, 291–313, <ext-link xlink:href="https://doi.org/10.5194/amt-11-291-2018" ext-link-type="DOI">10.5194/amt-11-291-2018</ext-link>, 2018.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Long-term evaluation of air sensor technology under ambient conditions in Denver, Colorado</article-title-html>
<abstract-html><p>Air pollution sensors are quickly proliferating for use in a wide variety of
applications, with a low price point that supports use in high-density
networks, citizen science, and individual consumer use. This emerging
technology motivates the assessment under real-world conditions, including
varying pollution levels and environmental conditions. A seven-month,
systematic field evaluation of low-cost air pollution sensors was performed
in Denver, Colorado, over 2015–2016; the location was chosen to evaluate the
sensors in a high-altitude, cool, and dry climate. A suite of particulate
matter (PM), ozone (O<sub>3</sub>), and nitrogen dioxide (NO<sub>2</sub>) sensors were
deployed in triplicate and were collocated with federal equivalent method
(FEM) monitors at an urban regulatory site. Sensors were evaluated for their
data completeness, correlation with reference monitors, and ability to
reproduce trends in pollution data, such as daily concentration values and
wind-direction patterns. Most sensors showed high data completeness when data
loggers were functioning properly. The sensors displayed a range of
correlations with reference instruments, from poor to very high (e.g.,
hourly-average PM Pearson correlations with reference measurements varied
from 0.01 to 0.86). Some sensors showed a change in response to laboratory
audits/testing from before the sampling campaign to afterwards, such as
Aeroqual, where the O<sub>3</sub> response slope changed from about 1.2 to 0.6.
Some PM sensors measured wind-direction and time-of-day trends similar to
those measured by reference monitors, while others did not. This study showed
different results for sensor performance than previous studies performed by
the U.S. EPA and others, which could be due to different geographic location,
meteorology, and aerosol properties. These results imply that continued field
testing is necessary to understand emerging air sensing technology.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Borrego, C., Costa, A. M., Ginja, J., Amorim, M., Coutinho, M., Karatzas,
K., Sioumis, T., Katsifarakis, N., Konstantinidis, K., De Vito, S.,
Esposito, E., Smith, P., André, N., Gérard, P., Francis, L. A.,
Castell, N., Schneider, P., Viana, M., Minguillón, M. C., Reimringer,
W., Otjes, R. P., von Sicard, O., Pohle, R., Elen, B., Suriano, D., Pfister,
V., Prato, M., Dipinto, S., and Penza, M.: Assessment of air quality
microsensors versus reference methods: The EuNetAir joint exercise,
Atmos. Environ., 147, 246–263,
<a href="https://doi.org/10.1016/j.atmosenv.2016.09.050" target="_blank">https://doi.org/10.1016/j.atmosenv.2016.09.050</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Crilley, L. R., Shaw, M., Pound, R., Kramer, L. J., Price, R., Young, S., Lewis, A. C., and Pope, F. D.: Evaluation of a
low-cost optical particle counter (Alphasense OPC-N2) for ambient air monitoring, Atmos. Meas. Tech., 11, 709–720,
<a href="https://doi.org/10.5194/amt-11-709-2018" target="_blank">https://doi.org/10.5194/amt-11-709-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Cross, E. S., Williams, L. R., Lewis, D. K., Magoon, G. R., Onasch, T. B., Kaminsky, M. L., Worsnop, D. R., and Jayne, J. T.:
Use of electrochemical sensors for measurement of air pollution: correcting interference response and validating measurements,
Atmos. Meas. Tech., 10, 3575–3588, <a href="https://doi.org/10.5194/amt-10-3575-2017" target="_blank">https://doi.org/10.5194/amt-10-3575-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Gao, M., Cao, J., and Seto, E.: A distributed network of low-cost continuous
reading sensors to measure spatiotemporal variations of PM2.5 in Xi'an,
China, Environ. Pollut., 199, 56–65,
<a href="https://doi.org/10.1016/j.envpol.2015.01.013" target="_blank">https://doi.org/10.1016/j.envpol.2015.01.013</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Hagan, D. H., Isaacman-VanWertz, G., Franklin, J. P., Wallace, L. M. M., Kocar, B. D., Heald, C. L., and Kroll, J. H.:
Calibration and assessment of electrochemical air quality sensors by co-location with regulatory-grade instruments,
Atmos. Meas. Tech., 11, 315–328, <a href="https://doi.org/10.5194/amt-11-315-2018" target="_blank">https://doi.org/10.5194/amt-11-315-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Holstius, D. M., Pillarisetti, A., Smith, K. R., and Seto, E.: Field calibrations of a low-cost aerosol sensor at a
regulatory monitoring site in California, Atmos. Meas. Tech., 7, 1121–1131, <a href="https://doi.org/10.5194/amt-7-1121-2014" target="_blank">https://doi.org/10.5194/amt-7-1121-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Jiao, W., Hagler, G., Williams, R., Sharpe, R., Brown, R., Garver, D., Judge, R., Caudill, M., Rickard, J., Davis, M.,
Weinstock, L., Zimmer-Dauphinee, S., and Buckley, K.: Community Air Sensor Network (CAIRSENSE) project: evaluation of
low-cost sensor performance in a suburban environment in the southeastern United States, Atmos. Meas. Tech., 9, 5281–5292, <a href="https://doi.org/10.5194/amt-9-5281-2016" target="_blank">https://doi.org/10.5194/amt-9-5281-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Kaufman, A., Williams, R., Barzyk, T., Greenberg, M., O'Shea, M., Sheridan,
P., Hoang, A., Ash, C., Teitz, A., Mustafa, M., and Garvey, S.: A Citizen
Science and Government Collaboration: Developing Tools to Facilitate
Community Air Monitoring, Environmental Justice, 10, 51–61,
<a href="https://doi.org/10.1089/env.2016.0044" target="_blank">https://doi.org/10.1089/env.2016.0044</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Kumar, P., Morawska, L., Martani, C., Biskos, G., Neophytou, M., Di
Sabatino, S., Bell, M., Norford, L., and Britter, R.: The rise of low-cost
sensing for managing air pollution in cities, Environ. Int., 75, 199–205,
2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Lewis, A. and Edwards, P.: Validate personal air-pollution sensors,
Nature, 535, 29–31, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Lewis, A. C., Lee, J. D., Edwards, P. M., Shaw, M. D., Evans, M. J., Moller,
S. J., Smith, K. R., Buckley, J. W., Ellis, M., Gillot, S. R., and White,
A.: Evaluating the performance of low cost chemical sensors for air
pollution research, Faraday Discuss., 189, 85–103, <a href="https://doi.org/10.1039/C5FD00201J" target="_blank">https://doi.org/10.1039/C5FD00201J</a>,
2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Manikonda, A., Zíková, N., Hopke, P. K., and Ferro, A. R.:
Laboratory assessment of low-cost PM monitors, J. Aerosol Sci.,
102, 29–40, <a href="https://doi.org/10.1016/j.jaerosci.2016.08.010" target="_blank">https://doi.org/10.1016/j.jaerosci.2016.08.010</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
McKercher, G. R. and Vanos, J. K.: Low-cost mobile air pollution monitoring
in urban environments: a pilot study in Lubbock, Texas, Environ. Technol.,
39,
1505–1514,
<a href="https://doi.org/10.1080/09593330.2017.1332106" target="_blank">https://doi.org/10.1080/09593330.2017.1332106</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
McKercher, G. R., Salmond, J. A., and Vanos, J. K.: Characteristics and
applications of small, portable gaseous air pollution monitors,
Environ. Pollut., 223, 102–110,
<a href="https://doi.org/10.1016/j.envpol.2016.12.045" target="_blank">https://doi.org/10.1016/j.envpol.2016.12.045</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Mead, M., Popoola, O., Stewart, G., Landshoff, P., Calleja, M., Hayes, M.,
Baldovi, J., McLeod, M., Hodgson, T., Dicks, J., Lewis, A. C., Cohen, J.,
Baron, R., Saffell, J., and Jones, R.: The use of electrochemical sensors
for monitoring urban air quality in low-cost, high-density networks, Atmos.
Environ., 70, 186–203, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Mukherjee, A., Stanton, G. L., Graham, R. A., and Roberts, T. P.: Assessing
the Utility of Low-Cost Particulate Matter Sensors over a 12-Week Period in
the Cuyama Valley of California, Sensors, 17, 1805, <a href="https://doi.org/10.3390/s17081805" target="_blank">https://doi.org/10.3390/s17081805</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti,
C., Yasar, A., and Rickerby, D.: End-user perspective of low-cost sensors
for outdoor air pollution monitoring, Sci. Total Environ.,
607–608, 691–705, <a href="https://doi.org/10.1016/j.scitotenv.2017.06.266" target="_blank">https://doi.org/10.1016/j.scitotenv.2017.06.266</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Ramaswami, A., Russell, A. G., Culligan, P. J., Sharma, K. R., and Kumar,
E.: Meta-principles for developing smart, sustainable, and healthy cities,
Science, 352, 940–943, <a href="https://doi.org/10.1126/science.aaf7160" target="_blank">https://doi.org/10.1126/science.aaf7160</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R.
W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., and Preuss,
P. W.: The Changing Paradigm of Air Pollution Monitoring, Environ. Sci.
Technol., 47, 11369–11377, <a href="https://doi.org/10.1021/es4022602" target="_blank">https://doi.org/10.1021/es4022602</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Sousan, S., Koehler, K., Hallett, L., and Peters, T. M.: Evaluation of the
Alphasense Optical Particle Counter (OPC-N2) and the Grimm Portable Aerosol
Spectrometer (PAS-1.108), Aerosol Sci. Tech., 50, 1352–1365,
<a href="https://doi.org/10.1080/02786826.2016.1232859" target="_blank">https://doi.org/10.1080/02786826.2016.1232859</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
South Coast Air Quality Management District Air Quality Sensor Performance
Evaluation Center: AQ-SPEC Home Page, available at: <a href="http://www.aqmd.gov/aq-spec" target="_blank">http://www.aqmd.gov/aq-spec</a>, last access: 5 December
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
U.S. EPA: Air Sensor Toobox, available at: <a href="https://www.epa.gov/air-sensor-toolbox" target="_blank">https://www.epa.gov/air-sensor-toolbox</a>,
last access: 5 December 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., and Biswas, P.: Laboratory
Evaluation and Calibration of Three Low-Cost Particle Sensors for
Particulate Matter Measurement, Aerosol Sci. Tech., 49,
1063–1077, <a href="https://doi.org/10.1080/02786826.2015.1100710" target="_blank">https://doi.org/10.1080/02786826.2015.1100710</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Williams, R.: CAIRSENSE Denver, available at: <a href="https://edg.epa.gov" target="_blank">https://edg.epa.gov</a>, las access: 6
August
2018.

</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Williams, R., Watkins, T., and Long, R.: Low cost sensor calibration options,
Environmental Manager, 10–15, January 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Woodall, M. G., Hoover, D. M., Williams, R., Benedict, K., Harper, M., Soo,
J.-C., Jarabek, M. A., Stewart, J. M., Brown, S. J., Hulla, E. J., Caudill,
M., Clements, L. A., Kaufman, A., Parker, J. A., Keating, M., Balshaw, D.,
Garrahan, K., Burton, L., Batka, S., Limaye, S. V., Hakkinen, J. P., and
Thompson, B.: Interpreting Mobile and Handheld Air Sensor Readings in
Relation to Air Quality Standards and Health Effect Reference Values:
Tackling the Challenges, Atmosphere, 8, 182, <a href="https://doi.org/10.3390/atmos8100182" target="_blank">https://doi.org/10.3390/atmos8100182</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Zimmerman, N., Presto, A. A., Kumar, S. P. N., Gu, J., Hauryliuk, A., Robinson, E. S., Robinson, A. L., and R. Subramanian:
A machine learning calibration model using random forests to improve sensor performance for lower-cost air quality monitoring,
Atmos. Meas. Tech., 11, 291–313, <a href="https://doi.org/10.5194/amt-11-291-2018" target="_blank">https://doi.org/10.5194/amt-11-291-2018</a>, 2018.
</mixed-citation></ref-html>--></article>
