<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0"><?xmltex \makeatother\@nolinetrue\makeatletter?>
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-13-1181-2020</article-id><title-group><article-title>Effect of aerosol composition on the performance of low-cost optical
particle counter correction factors</article-title><alt-title>Effect of aerosol composition on low-cost OPC correction factors</alt-title>
      </title-group><?xmltex \runningtitle{Effect of aerosol composition on low-cost OPC correction factors}?><?xmltex \runningauthor{L. R. Crilley}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1 aff8">
          <name><surname>Crilley</surname><given-names>Leigh R.</given-names></name>
          <email>lcrilley@yorku.ca</email>
        <ext-link>https://orcid.org/0000-0003-2268-9956</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Singh</surname><given-names>Ajit</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-0986-2064</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Kramer</surname><given-names>Louisa J.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-0823-6638</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Shaw</surname><given-names>Marvin D.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9954-243X</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Alam</surname><given-names>Mohammed S.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Apte</surname><given-names>Joshua S.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-2796-3478</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Bloss</surname><given-names>William J.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3017-4461</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Hildebrandt Ruiz</surname><given-names>Lea</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-8378-1882</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4 aff5">
          <name><surname>Fu</surname><given-names>Pingqing</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-6249-2280</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Fu</surname><given-names>Weiqi</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Gani</surname><given-names>Shahzad</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6966-0520</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Gatari</surname><given-names>Michael</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9193-6901</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Ilyinskaya</surname><given-names>Evgenia</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3663-9506</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Lewis</surname><given-names>Alastair C.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Ng'ang'a</surname><given-names>David</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Sun</surname><given-names>Yele</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2354-0221</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Whitty</surname><given-names>Rachel C. W.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Yue</surname><given-names>Siyao</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1320-9279</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Young</surname><given-names>Stuart</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Pope</surname><given-names>Francis D.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-6583-8347</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>School of Geography, Earth and Environmental Sciences, University of
Birmingham, Birmingham, UK</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>National Centre for Atmospheric Science, Wolfson Atmospheric Chemistry
Laboratories, University of York, York, UK</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Department of Civil, Architectural and Environmental Engineering, The
University of Texas at Austin, Austin, Texas, USA</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Institute of Surface-Earth System Science, Tianjin University,
Tianjin, China</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>Institute of Atmospheric Physics, Chinese Academy of Sciences,
Beijing, China</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Institute of Nuclear Science and Technology, University of Nairobi,
Nairobi, Kenya</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>School of Earth and Environment, University of Leeds, Leeds, UK</institution>
        </aff>
        <aff id="aff8"><label>a</label><institution>now at: Department of Chemistry, York University, Toronto, Canada</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Leigh R. Crilley (lcrilley@yorku.ca)</corresp></author-notes><pub-date><day>10</day><month>March</month><year>2020</year></pub-date>
      
      <volume>13</volume>
      <issue>3</issue>
      <fpage>1181</fpage><lpage>1193</lpage>
      <history>
        <date date-type="received"><day>1</day><month>October</month><year>2019</year></date>
           <date date-type="rev-request"><day>7</day><month>October</month><year>2019</year></date>
           <date date-type="rev-recd"><day>29</day><month>January</month><year>2020</year></date>
           <date date-type="accepted"><day>2</day><month>February</month><year>2020</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2020 </copyright-statement>
        <copyright-year>2020</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/.html">This article is available from https://amt.copernicus.org/articles/.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e303">There is considerable interest in using low-cost optical
particle counters (OPCs) to supplement existing routine air quality networks
that monitor particle mass concentrations. In order to do this, low-cost OPC
data need to be comparable with particle mass reference
instrumentation; however, there is currently no widely agreed upon methodology to accomplish this. Aerosol
hygroscopicity is known to be a key parameter to consider when correcting
particle mass concentrations derived from low-cost OPCs, particularly at
high ambient relative humidity (RH). Correction factors have been developed
that apply <inline-formula><mml:math id="M1" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory to correct for the influence of water
uptake by hygroscopic aerosols. We have used datasets of co-located
reference particle measurements and low-cost OPC (OPC-N2, Alphasense) measurements, collected in four cities on three continents, to explore the performance of
this correction factor. We provide evidence that the elevated particle mass
concentrations, reported by the low-cost OPC relative to reference
instrumentation, are due to bulk aerosol hygroscopicity under different RH
conditions, which is determined by aerosol composition and, in particular, the
levels of hygroscopic aerosols (sulfate and nitrate). We exploit
measurements made in volcanic plumes in Nicaragua, which are predominantly
composed of sulfate aerosol, as a natural experiment to demonstrate this
behaviour in the ambient atmosphere; the observed humidogram from these measurements closely
resembles the calculated pure sulfuric acid humidogram. The results
indicate that the particle mass concentrations derived from low-cost OPCs
during periods of high RH (<inline-formula><mml:math id="M2" display="inline"><mml:mrow><mml:mi mathvariant="italic">&gt;</mml:mi><mml:mn mathvariant="normal">60</mml:mn></mml:mrow></mml:math></inline-formula> %) need to be corrected for
aerosol hygroscopic growth. We employed a correction factor based on <inline-formula><mml:math id="M3" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory and observed that the corrected OPC-N2 PM<inline-formula><mml:math id="M4" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass
concentrations were within 33 % of reference measurements at all sites.
The results indicated that a <inline-formula><mml:math id="M5" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value derived in situ (using suitable reference
instrumentation) would lead to the most accurate correction relative to
co-located reference instruments. Applying a <inline-formula><mml:math id="M6" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values from the literature in the
correction factor also resulted in improved OPC-N2 performance, with the measurements being within 50 % of the reference values. Therefore, for areas where suitable reference
instrumentation for developing a local correction factor is lacking, using a
literature <inline-formula><mml:math id="M7" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value can result in a reasonable correction. For
locations with low levels of hygroscopic aerosols and low RH values, a simple
calibration against gravimetric measurements (using suitable reference
instrumentation) would likely be sufficient. Whilst this study generated
correction factors specific for the<?pagebreak page1182?> Alphasense OPC-N2 sensor, the
calibration methodology developed is likely amenable to other low-cost PM
sensors.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e370">Advances in miniaturization technology have led to the development of many
different kinds of low-cost air pollution sensors, ranging from passive gas
samplers to miniaturized versions of reference instruments (Lewis et al., 2018; Jayaratne et al., 2018). The term
low-cost is relative and typically refers to the sensor being at least an
order of magnitude cheaper than corresponding reference instrumentation (Lewis et al., 2018). Monitoring
of key air pollutants (e.g. PM<inline-formula><mml:math id="M8" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>,
<inline-formula><mml:math id="M9" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) has traditionally been performed via reference
standard or equivalent monitors at fixed monitoring stations. However, this
approach can lack the necessary spatial coverage to properly assess personal
exposure due to significant spatial heterogeneity in the concentration of
air pollutants in urban areas (de Nazelle et al., 2017).
Low-cost sensors are an attractive option due to their reduced costs and
portability, making them viable for mobile or highly spatially resolved
measurements, to complement existing monitoring frameworks. This has led to
low-cost sensors becoming a common feature of an increasing number of air
pollution monitoring operations (Snyder et al., 2013; Morawska et al.,
2018).</p>
      <p id="d1e404">The trade-off when using low-cost sensors is that they are currently not as
accurate, precise, selective or sensitive when compared with research- or
regulatory-grade instrumentation (Mead et al., 2013; Lewis et al.,
2016, 2018; Smith et al., 2017; Crilley et al., 2018; Borrego et
al., 2016; Popoola et al., 2016). Consequently, low-cost sensors of air
pollutants need to be carefully characterized to ensure that they meet the
specific requirements of the intended application (Castell et
al., 2017). In their review, Morawska et al. (2018) concluded that
low-cost sensors were appropriate for many applications, such as
supplementing routine air quality measurements and engaging the public and
community groups. However, there is still work needed if low-cost sensors
are to be used for accurate exposure measurements or for
compliance monitoring in the future, which are both of particular interest in under-monitored
low- and middle-income countries (LMICs). LMICs typically have high urban air
pollution, but the resources and infrastructure are sometimes lacking to
support continuous classical reference air quality measurements (Pope et
al., 2018). One of the challenges with using low-cost sensors in this
setting is that there is currently no agreed upon methodology for the evaluation of
their accuracy and precision as well as their subsequent calibration (Lewis et
al., 2018).</p>
      <p id="d1e407">Airborne particulate matter (PM) is a key pollutant for air monitoring networks due to its well-established detrimental physical health effects (Cohen et al., 2005; Landrigan et al., 2018). In particular,
exposure to
fine particles (PM<inline-formula><mml:math id="M11" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>, particles with an aerodynamic diameter less than
2.5 <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m) is known to have multiple disease pathways (Landrigan et
al., 2018). Recently, short-term exposure to PM<inline-formula><mml:math id="M13" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> has been linked to
short-term cognitive decline (Shehab and Pope, 2019).
PM<inline-formula><mml:math id="M14" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass regulatory limits are based on the dry particle mass
concentration; thus, regulatory-grade particle mass instrumentation dries the
aerosol before measurement to record the dry aerosol mass concentrations.
Low-cost optical particle counters (OPCs) measure the particle diameter and
number concentrations using light scattering and convert these measurements to particle mass
concentrations by assuming particle sphericity and a uniform density.
Low-cost OPCs typically do not dry the aerosol before measurement, and this
can result in an overestimation of the dry particle size (compared with that
which would be determined after drying) under high-RH conditions (Crilley
et al., 2018; Jayaratne et al., 2018; Di Antonio et al., 2018), which is thought to be
related to the uptake of water by hygroscopic aerosol. Consequently, the
reported PM mass concentrations from low-cost OPCs are the wet particle mass
concentrations and need to be converted to dry particle mass
concentrations in order be comparable with regulatory standards and
reference instrumentation. One solution to measuring the dry mass of
particles would be the addition of a preconditioning drying step prior to the OPC measurements; however, this would result in higher costs, greater power consumption and less
instrument portability, thereby reducing the unique selling points (USPs) of
low-cost sensor devices.</p>
      <p id="d1e445">Recently, a methodology to correct the wet particle mass concentrations to
dry mass concentrations was proposed by Crilley et al. (2018) based upon the
<inline-formula><mml:math id="M15" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory (Petters and Kreidenweis, 2007). The <inline-formula><mml:math id="M16" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory describes the relationship between particle
hygroscopicity and volume using a single value, <inline-formula><mml:math id="M17" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>, and it can be adapted
to relate particle mass to average bulk hygroscopicity at a given RH.
Crilley et al. (2018) calculated <inline-formula><mml:math id="M18" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values representative of ambient bulk hygroscopicity using co-located reference instruments to determine a correction factor for the derived OPC-N2 (Alphasense) particle mass concentrations. Application of this in situ correction factor by Crilley and
co-workers notably improved the OPC-N2 PM<inline-formula><mml:math id="M19" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> and PM<inline-formula><mml:math id="M20" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations to within 33 % of the reference instrumentation
at an urban background location with high ambient RH. Subsequently, Di Antonio
et al. (2018) proposed a similar method that applied <inline-formula><mml:math id="M21" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory to correct the particle size distribution measured by
the OPC-N2 and then calculated the particle mass fraction concentration
using this corrected particle size. Using this approach, Di Antonio and
co-workers also observed notable improvement in the OPC-N2 to within 43 % of the reference PM<inline-formula><mml:math id="M22" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations. Di Antonio and co-workers
assumed <inline-formula><mml:math id="M23" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values for their correction factor, based upon the assumed
major hygroscopic components of the aerosol mix (ammonium sulfate and
sodium chloride), which may not be realistic considering the complex
multi-compositional nature of urban particles.</p>
      <?pagebreak page1183?><p id="d1e519">It is clear that the aerosol hygroscopicity is a key parameter to consider
when correcting particle mass concentration derived by a low-cost OPC (Crilley et al., 2018; Di
Antonio et al., 2018). Aerosol hygroscopicity is
dependent on the chemical compounds present; consequently, the derived
correction factor may vary from location to location due to differences in the
particle bulk composition, shape and density. To investigate this, we
utilized datasets containing co-located particle measurements from reference
instruments and a low-cost OPC that were collected in four cities on three continents:
Birmingham, UK; Nairobi, Kenya; Delhi, India; and Beijing, China. Across
these four cities, the airborne particle composition and range of ambient RH varied considerably allowing for the exploration of sensor performance in response to these factors (composition and RH) and how these factors affected the calculated correction factors. We also report measurements taken near a
volcano in Nicaragua: a location that received regular volcanic plumes
that contained particles which were typically chemically homogenous. The aim
of this paper was to investigate whether a universal correction method can
be reasonably applied to reported particle mass concentrations from low-cost
OPCs across a wide variety of locations.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Method</title>
      <p id="d1e530">The datasets used in the current work were acquired at different times during several different
field campaigns, but the same type of low-cost particle
sensor was deployed at all five locations – the OPC-N2 manufactured by
Alphasense. This sensor has been described in detail in Sousan et al. (2016) and Crilley et al. (2018) and can be considered as a
miniaturized optical particle counter. The measured particle number
concentration from the OPC-N2 is converted via an onboard factory calibration to
particle mass concentrations for the PM<inline-formula><mml:math id="M24" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:math></inline-formula>, PM<inline-formula><mml:math id="M25" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> and PM<inline-formula><mml:math id="M26" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula> size
fractions according to European Standard EN 481 (OPC-N2 manual). Data
collection with the OPC-N2 followed the procedures outlined in Crilley et
al. (2018) at the four urban locations via a Raspberry Pi computer employing the
py-opc Python library (Hagan et al., 2018). Uncorrected PM mass
concentrations were used without any modification. In Birmingham, Delhi,
Beijing and Nairobi, the OPC-N2 was housed within a custom-built unit with
the same inlet length (12 cm <inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>/</mml:mo><mml:msup><mml:mn mathvariant="normal">8</mml:mn><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> diameter stainless steel tubing, see Crilley
et al. (2018) for details) and was placed outside. At Nicaragua, the OPC-N2
was part of the commercially available AQMesh system (Air Monitors), and the
uncorrected PM concentrations were extracted.</p>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Measurement locations</title>
      <p id="d1e585">All of the sites in this study, other than the volcanic Nicaraguan site, are
classed as urban background with respect to their respective cities. We have focused on
PM<inline-formula><mml:math id="M28" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations in this study, as this particle size fraction
was measured by reference instrumentation at all study sites. We also note
that we used a different OPC-N2 sensor at each site. Previous work has shown
that co-located multiple OPC-N2 sensors have an inter-unit precision of <inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:mn mathvariant="normal">22</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">13</mml:mn></mml:mrow></mml:math></inline-formula> % for PM<inline-formula><mml:math id="M30" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:math></inline-formula> mass
concentrations (Crilley et al., 2018). A summary of
the measurement locations is provided in Table 1.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e621">Summary of the measurement sites. Full details available in the
text. NA signifies not available. Custom housing for the OPC-N2 as per the
description in the text.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Location</oasis:entry>
         <oasis:entry colname="col2">Site</oasis:entry>
         <oasis:entry colname="col3">OPC-N2</oasis:entry>
         <oasis:entry colname="col4">Reference</oasis:entry>
         <oasis:entry colname="col5">Aerosol composition</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">description</oasis:entry>
         <oasis:entry colname="col3">housing</oasis:entry>
         <oasis:entry colname="col4">instrument</oasis:entry>
         <oasis:entry colname="col5">instrument</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Birmingham BAQS (Bham BAQS), UK</oasis:entry>
         <oasis:entry colname="col2">Urban background</oasis:entry>
         <oasis:entry colname="col3">Custom</oasis:entry>
         <oasis:entry colname="col4">GRIMM</oasis:entry>
         <oasis:entry colname="col5">NA</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Birmingham Tyburn (Bham Tyburn) , UK</oasis:entry>
         <oasis:entry colname="col2">Urban background</oasis:entry>
         <oasis:entry colname="col3">Custom</oasis:entry>
         <oasis:entry colname="col4">TEOM-FDMS</oasis:entry>
         <oasis:entry colname="col5">NA</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Beijing, China</oasis:entry>
         <oasis:entry colname="col2">Urban background</oasis:entry>
         <oasis:entry colname="col3">Custom</oasis:entry>
         <oasis:entry colname="col4">TEOM-FDMS</oasis:entry>
         <oasis:entry colname="col5">AMS</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Delhi, India</oasis:entry>
         <oasis:entry colname="col2">Urban background</oasis:entry>
         <oasis:entry colname="col3">Custom</oasis:entry>
         <oasis:entry colname="col4">TEOM-FDMS</oasis:entry>
         <oasis:entry colname="col5">ACSM</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Nairobi, Kenya</oasis:entry>
         <oasis:entry colname="col2">Urban background</oasis:entry>
         <oasis:entry colname="col3">Custom</oasis:entry>
         <oasis:entry colname="col4">Gravimetric</oasis:entry>
         <oasis:entry colname="col5">NA</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Masaya volcano, Nicaragua</oasis:entry>
         <oasis:entry colname="col2">Volcano</oasis:entry>
         <oasis:entry colname="col3">AQMesh</oasis:entry>
         <oasis:entry colname="col4">NA</oasis:entry>
         <oasis:entry colname="col5">NA</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<sec id="Ch1.S2.SS1.SSS1">
  <label>2.1.1</label><title>Birmingham, United Kingdom</title>
      <p id="d1e797">The OPCs were deployed at two urban background locations in Birmingham. The
first was the Birmingham Air Quality Supersite at Elms Road (BAQS; 52.4554<inline-formula><mml:math id="M31" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N, 1.9286<inline-formula><mml:math id="M32" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> W), which is
located on the University of Birmingham campus (Alam
et al., 2015) and will hereafter be referred to as “Bham BAQS”. The second
site was the Tyburn Road air monitoring station, which is part of the UK Automatic
Rural Urban Network (AURN), and will hereafter be referred to as “Bham Tyburn”. This
dataset has previously been described in Crilley et al. (2018), and the current work focuses on the
long-term measurements (October 2016 to February 2017) at Bham BAQS, using
the OPC-N2 that gave the most complete time series. The reference instrument
for PM<inline-formula><mml:math id="M33" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentration measurements at Bham Tyburn was a tapered
element oscillating microbalance with a filter dynamic measurement system
(TEOM-FDMS). The Bham Tyburn dataset is used for comparison with other sites that
had the same reference instrument (Beijing and Delhi, see Sect. 2.1.2 and
2.1.3). The reference instrument at Bham BAQS was a GRIMM portable aerosol
sampler (model 1.108) that was serviced and calibrated before the
measurements. The GRIMM is an OPC-type device that is similar to the low-cost
sensors, but it does contain a preconditioning step that reduces the internal
RH of the device. Previous work, based on co-located measurements with a TEOM-FDMS, has demonstrated that the GRIMM is not affected
by RH (Crilley et al., 2018).</p>
</sec>
<sec id="Ch1.S2.SS1.SSS2">
  <label>2.1.2</label><title>Beijing, China</title>
      <p id="d1e836">The measurements in Beijing formed part of “Air Pollution and Human
Health in a Chinese Megacity”, APHH-Beijing, which is
a joint UK–China programme addressing air quality in Beijing (Shi et al.,
2019). The measurements took place at the Chinese Academy of Science
Institute of Atmospheric Physics (IAP) tower campus (39.9735<inline-formula><mml:math id="M34" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N, 116.3723<inline-formula><mml:math id="M35" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> E),
located in the northern suburbs of Beijing. The OPC-N2 sampled on top of a
shipping container at a height of approximately 2.5 m from 5 to 9 December 2016. In
addition, co-located ground level measurements were obtained from a TEOM-FDMS set to measure PM<inline-formula><mml:math id="M36" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations as well as an Aerodyne
aerosol mass spectrometer (AMS; Xu et al., 2019).</p>
</sec>
<?pagebreak page1184?><sec id="Ch1.S2.SS1.SSS3">
  <label>2.1.3</label><title>Delhi, India</title>
      <p id="d1e874">The measurements in Delhi were part of “Air Pollution and Human Health in
an Indian Megacity” (APHH-Delhi, <uri>http://www.urbanair-india.org</uri>, last access: 3 March 2020), which is a joint UK–India
programme tackling air pollution in Delhi. The sampling location was the Indian
Institute of Technology Delhi (IITD) main campus in Hauz Khas (28.5464<inline-formula><mml:math id="M37" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N,
77.1913<inline-formula><mml:math id="M38" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> E), which is located in the southern suburbs of New Delhi. The instruments
were located on the roof (four stories) of Block IV at IITD. The inlet for the
co-located PM<inline-formula><mml:math id="M39" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> TEOM-FDMS was approximately 5 m from the OPC-N2 at the
same sampling height. On-line measurements of inorganic aerosol
concentrations were provided by an Aerodyne aerosol chemical speciation
monitor (ACSM), located nearby in Block V on the IITD campus, at the same
sampling height (Gani et al., 2019).</p>
</sec>
<sec id="Ch1.S2.SS1.SSS4">
  <label>2.1.4</label><title>Nairobi, Kenya</title>
      <p id="d1e915">The measurements in Nairobi have previously been reported in Pope et al. (2018).
These measurements are part of the “A Systems Approach to Air Pollution”
programme (ASAP East Africa, <uri>http://www.asap-eastafrica.com</uri>, 3 March 2020). In the
current work, we used the urban background data that were collected on the
rooftop of the American Wing building at the University of Nairobi (1.2801<inline-formula><mml:math id="M40" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> S, 36.8163<inline-formula><mml:math id="M41" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> E).
The sampling inlet was at a height of 17 m a.g.l. (metres above ground level) with unobstructed airflow in all directions. The measurement period was from
2 February to 24 March 2017. Calibration of the OPC was carried out in situ
using a standardized gravimetric approach that involved co-location of the OPC with
an Anderson dichotomous impactor (Sierra Instruments Inc., USA).</p>
</sec>
<sec id="Ch1.S2.SS1.SSS5">
  <label>2.1.5</label><title>Masaya volcano, Nicaragua</title>
      <p id="d1e947">Masaya is an active volcano that is currently degassing; due to its low
altitude (600 m a.s.l., metres above sea level), the volcanic plume causes persistent gas and PM air
pollution in nearby populated areas. The results presented are part of the
first study of high temporal and long-term measurements of PM and <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
concentrations in several populated areas near the Masaya volcano. Here, we will
discuss the results from station 789, which was set up in Pacaya community
(11.9553<inline-formula><mml:math id="M43" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N, 86.3013<inline-formula><mml:math id="M44" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> W, 870 m a.s.l.) 15 km to the west
of Masaya volcano. Because it is located at a higher altitude than the
degassing crater, the volcanic plume frequently grounds at this location. The station
was set up on a post approximately 6 m a.g.l. at the Susie Syke private clinic, where it was not obstructed by vegetation, buildings or other
objects. The site is not believed to be influenced by firewood burning. It
is located <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula> m from a paved highway (that is busy during the morning
and evening rush hours), but it is upwind of it during the predominant weather
conditions. Measurements were performed using an “AQMesh” pod, which is a
commercially available sensor package. <inline-formula><mml:math id="M46" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations were measured
using an Alphasense B4-series electrochemical sensor, whereas particle
concentrations were measured by the OPC-N2. Note that uncorrected particle mass
concentrations were extracted from the AQMesh. The AQMesh was operational
between 27 February 2017 and 15 December 2017. Gaps in the data time series
are due to power outages.</p>
</sec>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Description of the correction factor applied</title>
      <?pagebreak page1185?><p id="d1e1009">The methodology for the correction factor applied has previously been
described in detail by Crilley et al. (2018). Briefly, the correction factor
uses <inline-formula><mml:math id="M47" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory to relate the particle mass to
hygroscopicity for a given RH (Pope, 2010), according to Eq. (1):
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M48" display="block"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced open="(" close=")"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>m</mml:mi><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>o</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mfenced open="(" close=")"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>m</mml:mi><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>o</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfenced><mml:mo>+</mml:mo><mml:mfenced close=")" open="("><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mi mathvariant="italic">κ</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the water activity (<inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mtext>RH</mml:mtext><mml:mo>/</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula>); <inline-formula><mml:math id="M51" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are the
wet and dry (<inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:mtext>RH</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula> %) particle mass respectively; and <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are the density of the dry particles and water respectively. The
value for <inline-formula><mml:math id="M56" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>, which relates the bulk aerosol composition to
hygroscopicity, can be determined by the non-linear curve fitting of a
humidogram, calculated using the ratio of wet/dry particle mass as a
function of water activity (<inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:mtext>RH</mml:mtext><mml:mo>/</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula>). We have used the raw
mass concentrations as reported by the OPC-N2. We utilized the reference
instrument measurements (TEOM-FDMS and GRIMM, as indicated in Sect. 2.2)
as the dry particle mass, whereas the raw OPC-N2 measurements were the wet particle mass
concentration. The TEOM-FDMS employs a Nafion dryer and, therefore, measures
the dry particle mass concentration (Grover et al., 2006).
Equation (1) can be rearranged to calculate the correction factor <inline-formula><mml:math id="M59" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> as follows:
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M60" display="block"><mml:mrow><mml:mi>C</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi mathvariant="italic">κ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          To calculate the particle mass concentration from the measured particle number
size distribution, spherical particles of a uniform density and shape are
assumed by the OPC; this is not strictly true for airborne particles in an
urban atmosphere but is considered to be a standard approximation. For full
details, see Crilley et al. (2018). The OPC-N2 assumes the ambient particle
density to be 1.65 g cm<inline-formula><mml:math id="M61" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> across all size bins to derive the particle
mass concentrations from the measured particle number concentrations
(Crilley et al., 2018); therefore, we used this density for the dry
particles (<inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) in Eq. (2). We assume that the particle density is
uniform across the particle size distribution measured by the OPC-N2.
Furthermore, we assume that both the OPC-N2 and the reference instrument
respond to dry aerosol mass in the same way for all particles below the size
cut-off on the reference instrument. We also note that we assume that both the
OPC-N2 and the reference instrument responses are linear over the range of
measured concentrations at each site. The raw particle mass concentrations
derived by the OPC-N2 are corrected according to Eq. (3):
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M63" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mi mathvariant="normal">corr</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mi mathvariant="normal">raw</mml:mi></mml:msub></mml:mrow><mml:mi>C</mml:mi></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
      <p id="d1e1313">A wide range of ambient particle concentrations and relative humidity values were
observed across the different measurement locations, and an overview of these values is
provided in Table 2. Typically, low particle concentrations were observed in
Birmingham and Nairobi with higher humidity levels in Birmingham compared
with Nairobi (Table 2). Meanwhile, a high particle load was observed in Delhi
and Beijing, as would be expected for winter in these two cities. In Delhi,
there was a wide range of humidities observed (10 %–100 %), whereas it was relatively dry (median of 35 %) in
Beijing during the measurement periods. The observed difference in particle load and composition between
sites allows for the effect of relative humidity on the OPC-N2 measurements to be examined
and for the applied correction factor to be explored in the following sections.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e1319">Summary of measurement datasets. Reported OPC-N2
PM<inline-formula><mml:math id="M64" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations are uncorrected. For the Nicaragua
measurements, there was no co-located reference instrumentation. Only one 24 h average gravimetric PM<inline-formula><mml:math id="M65" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> concentration was available for Nairobi, which is presented with the stated measurement uncertainty.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Site</oasis:entry>
         <oasis:entry colname="col2">Date</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">RH</oasis:entry>
         <oasis:entry colname="col5">OPC-N2</oasis:entry>
         <oasis:entry colname="col6">Reference</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">(%)</oasis:entry>
         <oasis:entry colname="col5">PM<inline-formula><mml:math id="M66" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">PM<inline-formula><mml:math id="M67" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5">(<inline-formula><mml:math id="M68" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M69" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col6">(<inline-formula><mml:math id="M70" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M71" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Birmingham</oasis:entry>
         <oasis:entry colname="col2">Oct 2016–Feb 2017</oasis:entry>
         <oasis:entry colname="col3">Median</oasis:entry>
         <oasis:entry colname="col4">92</oasis:entry>
         <oasis:entry colname="col5">15</oasis:entry>
         <oasis:entry colname="col6">8.7</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">First, third quartiles</oasis:entry>
         <oasis:entry colname="col4">84, 97</oasis:entry>
         <oasis:entry colname="col5">7, 50</oasis:entry>
         <oasis:entry colname="col6">5.6, 13</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Range</oasis:entry>
         <oasis:entry colname="col4">44–99</oasis:entry>
         <oasis:entry colname="col5">0.3–566</oasis:entry>
         <oasis:entry colname="col6">0.5–63</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Beijing</oasis:entry>
         <oasis:entry colname="col2">Dec 2016</oasis:entry>
         <oasis:entry colname="col3">Median</oasis:entry>
         <oasis:entry colname="col4">35</oasis:entry>
         <oasis:entry colname="col5">47</oasis:entry>
         <oasis:entry colname="col6">65</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">First, third quartiles</oasis:entry>
         <oasis:entry colname="col4">25, 43</oasis:entry>
         <oasis:entry colname="col5">7, 96</oasis:entry>
         <oasis:entry colname="col6">10, 134</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Range</oasis:entry>
         <oasis:entry colname="col4">13–81</oasis:entry>
         <oasis:entry colname="col5">3–274</oasis:entry>
         <oasis:entry colname="col6">2.7–208</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Delhi</oasis:entry>
         <oasis:entry colname="col2">Jan–Feb 2018</oasis:entry>
         <oasis:entry colname="col3">Median</oasis:entry>
         <oasis:entry colname="col4">62</oasis:entry>
         <oasis:entry colname="col5">127</oasis:entry>
         <oasis:entry colname="col6">164</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">First, third quartiles</oasis:entry>
         <oasis:entry colname="col4">37, 80</oasis:entry>
         <oasis:entry colname="col5">52, 301</oasis:entry>
         <oasis:entry colname="col6">110, 207</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Range</oasis:entry>
         <oasis:entry colname="col4">9–100</oasis:entry>
         <oasis:entry colname="col5">12–1113</oasis:entry>
         <oasis:entry colname="col6">50–478</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Nairobi</oasis:entry>
         <oasis:entry colname="col2">Feb–Mar 2017</oasis:entry>
         <oasis:entry colname="col3">Median</oasis:entry>
         <oasis:entry colname="col4">51</oasis:entry>
         <oasis:entry colname="col5">28</oasis:entry>
         <oasis:entry colname="col6"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">First, third quartiles</oasis:entry>
         <oasis:entry colname="col4">37, 66</oasis:entry>
         <oasis:entry colname="col5">21, 41</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mn mathvariant="normal">27.6</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">6.8</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Range</oasis:entry>
         <oasis:entry colname="col4">16–89</oasis:entry>
         <oasis:entry colname="col5">4–135</oasis:entry>
         <oasis:entry colname="col6"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Nicaragua</oasis:entry>
         <oasis:entry colname="col2">Feb–Dec 2017</oasis:entry>
         <oasis:entry colname="col3">Median</oasis:entry>
         <oasis:entry colname="col4">81</oasis:entry>
         <oasis:entry colname="col5">6.6</oasis:entry>
         <oasis:entry colname="col6"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">First, third quartiles</oasis:entry>
         <oasis:entry colname="col4">69, 86</oasis:entry>
         <oasis:entry colname="col5">3.5, 15</oasis:entry>
         <oasis:entry colname="col6">NA</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Range</oasis:entry>
         <oasis:entry colname="col4">39–91</oasis:entry>
         <oasis:entry colname="col5">0.5–742</oasis:entry>
         <oasis:entry colname="col6"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Effect of RH on the OPC-N2 measurements at all sites</title>
      <p id="d1e1803">To explore if there was evidence of an artefact in the OPC-N2-derived
PM<inline-formula><mml:math id="M73" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations due to RH, we plotted the reported PM<inline-formula><mml:math id="M74" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations
from the OPC-N2 as a function of RH (Fig. 1 and Fig. S1 in the Supplement). From Fig. 1, there is clear influence of RH on the
measurements performed in Delhi and Birmingham, which is evidenced by the observed
exponential increase in particle mass with RH (Fig. 1a, d). In Beijing,
the observed stepwise increase in the derived measured particle mass between
a RH of 40 % and 50 % may point to deliquescence of a predominant PM
component (Fig. 1c), which is explored further in later sections. What was evident from
these three sites (Beijing, Birmingham and Delhi) was that there was a large spread
in the derived PM<inline-formula><mml:math id="M75" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations at high RH, which likely reflects
the heterogeneous nature of the particle composition and, hence,
hygroscopicity.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e1835">Plot of the reported PM<inline-formula><mml:math id="M76" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentration from the
OPC-N2 against ambient RH for the whole measurement period in Delhi <bold>(a)</bold>,
Nairobi <bold>(b)</bold>, Beijing <bold>(c)</bold>, Bham BAQS <bold>(d)</bold>, Nicaragua <bold>(e)</bold> and Bham Tyburn <bold>(f)</bold>.
Note the different <inline-formula><mml:math id="M77" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M78" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis scales.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f01.png"/>

        </fig>

      <p id="d1e1886">Meanwhile at Nairobi, the derived concentrations from the OPC-N2 appeared to
be independent of RH. Typically, during the dry season in Nairobi, airborne
mineral dust comprises a large fraction of PM<inline-formula><mml:math id="M79" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> (35 % annual mean; Gaita et al., 2014), which is
known to have low hygroscopicity.
Furthermore, we note that the measurements in Nairobi were performed during
the dry season and, as a result, the ambient RH was typically less than
85 %: this was the threshold RH value identified in Crilley et al. (2018) at which the OPC-N2
becomes significantly sensitive to RH. Lower humidity levels combined with the low
hygroscopicity of the aerosol in Nairobi was the likely reason why there
was little evidence of a RH artefact observed in the OPC-N2 measurements (Pope et
al., 2018). Therefore, a simple calibration against gravimetric measurements
is likely to be sufficient in locations with low RH and a low proportion of
hygroscopic aerosols, such as Nairobi.</p>
      <p id="d1e1899">As posited in Crilley et al. (2018), the RH artefact in the OPC-N2 measurements was
likely related to the ambient aerosol bulk hygroscopicity. Therefore, in Fig. 2 we plotted humidograms for the sites from Fig. 1 that showed evidence of a RH effect,
where reference particle mass concentration data were available (i.e.
Birmingham, Delhi and Beijing; Table 2). In Beijing, there
were insufficient data at high RH levels due to the short sampling
period (4 d). The factors affecting the response of the OPC-N2 in Beijing are explored in more
detail in Sect. 3.2.1. A quasi-exponential increase in the ratio the OPC-N2
to reference instrument concentrations at high RH levels was observed in Birmingham
and Delhi, as would be expected if the aerosols were undergoing hygroscopic
growth (Fig. 2). Using <inline-formula><mml:math id="M80" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory (Petters and
Kreidenweis, 2007), the calculated <inline-formula><mml:math id="M81" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values were 0.1 and 0.16 for Birmingham
and Delhi respectively. These <inline-formula><mml:math id="M82" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values are typical of continental
regions with high organic loadings (Pringle et al.,
2010). While high organic loadings would be expected for Delhi during
winter, there are also significant<?pagebreak page1186?> loadings of hygroscopic aerosols such as
sulfate and nitrate (Gani et al., 2019), which is explored in more detail in the following. Differences in aerosol composition
would likely explain why the calculated <inline-formula><mml:math id="M83" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value at Bham BAQS (0.1) was
lower than that observed at Bham Tyburn (0.38–0.41; Crilley et al., 2018).
Previous work in Birmingham has demonstrated that the proportion of ammonium
sulfate and nitrate decreases in winter compared with summer (Yin et al., 2010), which may explain the observed lower
<inline-formula><mml:math id="M84" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value over winter. What becomes evident from Fig. 2 is that
different <inline-formula><mml:math id="M85" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values were observed at each site. If the aerosol
composition was broadly similar at each site, we would expect the same
<inline-formula><mml:math id="M86" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value. This suggests that the aerosol composition varies
significantly over the different measurement sites. The scatter in the OPC <inline-formula><mml:math id="M87" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> TEOM
observed in Fig. 2 as a function of RH was likely due to temporal variability
in the aerosol composition due to changing sources and sinks (both local and
regional).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e1961">Humidograms with the corresponding <inline-formula><mml:math id="M88" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> fit (shown in
colour) for Delhi <bold>(a)</bold>, Beijing <bold>(b)</bold>, Bham BAQS <bold>(c)</bold> and Bham Tyburn <bold>(d)</bold>. Note the
different <inline-formula><mml:math id="M89" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axis and <inline-formula><mml:math id="M90" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis scales. The two-stage correction factor
described in Sect. 3.3.1 has not been applied for these humidograms.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f02.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Effect of aerosol composition on the OPC-N2 RH correction factor</title>
<sec id="Ch1.S3.SS2.SSS1">
  <label>3.2.1</label><title>Mixed aerosol composition (urban)</title>
      <p id="d1e2020">To explore the effect of aerosol composition on the correction factor for the
OPC-N2, we first focus on the Beijing and Delhi measurements (as co-located
on-line aerosol composition data were available at these two sites). During
the measurements in Beijing, there were periods when the OPC-N2 and TEOM
were in reasonable agreement, which typically occurred at lower PM concentrations (as
observed by the regulatory-grade equipment). Figure 3a demonstrates that there was linear
relationship between the reported OPC-N2 and TEOM concentrations at
concentrations below approximately 150 <inline-formula><mml:math id="M91" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M92" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (<inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:msup><mml:mi>r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of
0.85), with a slope of 0.72. When the PM<inline-formula><mml:math id="M94" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations were
above 150 <inline-formula><mml:math id="M95" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M96" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, the relationship appeared to deviate from
linearity, although these were also the times when the RH was higher
(<inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:mi mathvariant="italic">&gt;</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:mrow></mml:math></inline-formula> %, Fig. 3a). Generally, periods of high RH also
corresponded to periods of relatively high sulfate concentrations (Fig. 3b)
and, to a lesser extent, high particle nitrate concentrations (Fig. S2). Both nitrate and sulfate aerosol have high
hygroscopicities (Petters and Kreidenweis, 2007).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e2096">Derived OPC-N2 uncorrected PM<inline-formula><mml:math id="M98" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations
against TEOM PM<inline-formula><mml:math id="M99" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentration measurements coloured by ambient
RH <bold>(a)</bold> and the fraction of sulfate to the total PM<inline-formula><mml:math id="M100" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass <bold>(b)</bold> in Beijing.
The straight line indicates the linear regression fit for concentrations
below 150 <inline-formula><mml:math id="M101" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<inline-formula><mml:math id="M102" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. The dashed line is the <inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> line.</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f03.png"/>

          </fig>

      <p id="d1e2171">Similar trends were also observed in the Delhi measurements. Generally, at
low RH there appears to be a linear relationship between the reported OPC-N2
and TEOM concentrations (Fig. 4a), but this deviates from linearity at high
RH, which is similar to the behaviour observed in Beijing. For periods when the ambient RH in
Delhi was less than 50 %, we observed that the OPC-N2 generally recorded
PM<inline-formula><mml:math id="M104" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations that were half those of the TEOM (slope of 0.48 and
<inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:msup><mml:mi>r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of 0.55). This was broadly similar to the behaviour observed in Beijing (Fig. 3a) and
suggests that the OPC-N2 generally under-reports PM<inline-formula><mml:math id="M106" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass
concentrations at low RH (<inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:mi mathvariant="italic">&lt;</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:mrow></mml:math></inline-formula> %). It is also apparent from Fig. 4a that
there were times in Delhi when the RH was high (<inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mi mathvariant="italic">&gt;</mml:mi><mml:mn mathvariant="normal">80</mml:mn></mml:mrow></mml:math></inline-formula> %), but the PM<inline-formula><mml:math id="M109" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations from the OPC-N2 showed a similar
relationship to the TEOM measurements as that seen at low RH levels.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e2236">Derived OPC-N2 uncorrected PM<inline-formula><mml:math id="M110" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations
against TEOM PM<inline-formula><mml:math id="M111" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentration measurements coloured by
<bold>(a)</bold> ambient RH and <bold>(b)</bold> the sum of the particle sulfate and
nitrate concentrations in Delhi. The solid line is the <inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> line, and the dashed
lines are the <inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.5</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> lines.</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f04.png"/>

          </fig>

      <?pagebreak page1187?><p id="d1e2306">Therefore, we plotted the relationship of the OPC-N2 and TEOM PM<inline-formula><mml:math id="M115" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass
concentrations coloured by the sum of the sulfate and nitrate concentrations
(Fig. 4b, see Fig. S3 in the Supplement for individual plots of sulfate and nitrate); generally, when the concentration of these species and the RH were high, we
observed notably higher OPC-N2 concentrations relative to the reference.
Both sulfate and nitrate are highly hygroscopic aerosols which
suggests that the high readings by the OPC-N2 relative to the TEOM in
Beijing and Delhi were due to water uptake by hygroscopic particles, as
suggested by Crilley et al. (2018). From Figs. 3 and 4, it appears that this
effect occurred at RH values above 50 %, which is below the deliquescence point of
ammonium sulfate (79 %) and indicates that the ammonium sulfate component of
the aerosol was in a metastable state. Aerosols with multi-component
mixtures are observed to deliquesce earlier than the deliquescence points of
the individual components (e.g. Pope et al., 2010). It is noted
that the nitrate component of the aerosols have a smoother continual uptake
of water with respect to RH (Gibson et al., 2006; Hu et al., 2010).</p>
</sec>
<sec id="Ch1.S3.SS2.SSS2">
  <label>3.2.2</label><title>Homogenous aerosol composition (volcano plume)</title>
      <p id="d1e2326">The composition of fresh volcanic plumes are typically dominated by sulfuric
acid; therefore, these plumes offer an opportunity to explore the use of <inline-formula><mml:math id="M116" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory to develop the correction factor in a substantially
homogenous aerosol mix under ambient conditions. If the RH artefact is due
to aerosol hygroscopicity, the resultant humidogram using data
collected by the OPC-N2 in the plume should resemble that for sulfuric
acid. To derive the volcanic plume humidogram, shown in Fig. 5, the
following steps were taken: the plume was identified at station 789 when the
co-located gas phase <inline-formula><mml:math id="M117" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurement was greater than 20 ppm;<?pagebreak page1188?> the
aerosol within the plume was assumed to be composed solely of sulfuric acid
with a corresponding <inline-formula><mml:math id="M118" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value of 1.19 (Wexler and Clegg,
2002); the dry mass of the volcanic particles were calculated using Eq. (1),
with a RH input from the co-located measurements at site 789; and the derived
humidogram was compared with the pure sulfuric acid humidogram calculated
using the Extended Aerosol Inorganics Model (E-AIM, Model I; Fig. 5). The observed agreement between the model and
measurements strongly points to particle hygroscopic growth driving the high
particle mass concentrations observed by the OPC-N2 at high RH.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e2356">Comparison of humidograms from pure sulfuric acid and the Nicaragua volcanic plume. Circles denote the Nicaragua plume
aerosol, and the dashed line represents the modelled sulfuric acid humidogram from the E-AIM model.</p></caption>
            <?xmltex \igopts{width=156.490157pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f05.png"/>

          </fig>

</sec>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Evaluation of the OPC-N2 performance in Delhi and Birmingham</title>
      <p id="d1e2374">During the measurements in Delhi, the OPC-N2 typically over-reported the
PM<inline-formula><mml:math id="M119" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations relative to the reference (Fig. 6a). The
OPC-N2 assumes a uniform particle density of 1.65 g cm<inline-formula><mml:math id="M120" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> in the
particle counts to mass conversion, and this density may be inappropriate
for Delhi aerosol during winter. Previous measurements of aerosol density
during winter in Delhi at midday were <inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.28</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math id="M122" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> on average (Sarangi et al., 2016), which is lower than that applied
by the OPC-N2. Generally, the OPC <inline-formula><mml:math id="M123" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> TEOM ratio was below 1 (Fig. 2a) and would not fully explain this discrepancy. Is can be noted from Fig. 6a that higher
PM<inline-formula><mml:math id="M124" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations relative to the reference were reported by
the OPC-N2 towards the start of the measurement period (Fig. 6a), generally
during periods of high RH (e.g. 25–29 January, Fig. 6b). We
also note that the reported concentrations from the OPC-N2 towards the end of
the measurements in Delhi (11 February onwards, Fig. 6a) were in better
agreement with reference. The cause of this change in performance is unclear,
but it could reflect lower RH values or changes in the aerosol composition.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><label>Figure 6</label><caption><p id="d1e2441">Time series of reported OPC-N2 and TEOM-FDMS PM<inline-formula><mml:math id="M125" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>
mass concentrations <bold>(a)</bold> and ambient RH <bold>(b)</bold> at IIT Delhi.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f06.png"/>

        </fig>

      <p id="d1e2465">As the reported OPC-N2 concentrations in Birmingham and Delhi demonstrated
an artefact due to RH (Fig. 2), we applied the correction factor from
Crilley et al. (2018), using the in situ locally derived <inline-formula><mml:math id="M126" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values. In
addition, the <inline-formula><mml:math id="M127" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value for ammonium sulfate (0.61) was also used, as Di
Antonio et al. (2018) suggested it may be more representative for
urban aerosols. The results for the correction factors relative to the
co-located reference instruments are summarized in Table 3. Compared with the
uncorrected OPC-N2 concentrations, the application of a correction factor with
both <inline-formula><mml:math id="M128" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values resulted in improved performance of the reported
concentrations<?pagebreak page1189?> relative to the reference. However, the use of the locally
derived <inline-formula><mml:math id="M129" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> resulted in the best correction of the OPC-N2 (to
within 33 % of the reference measurements) compared with using the ammonium
sulfate <inline-formula><mml:math id="M130" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value (Table 3).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e2507">Slopes of uncorrected and corrected PM<inline-formula><mml:math id="M131" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass
concentrations from the OPC-N2 relative to the reference instruments
(<inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:msup><mml:mi>r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> in parentheses). Intercepts were not constrained to zero. There were
four OPC-N2 sensors measuring at Bham Tyburn, and the range of measurements from these instruments is presented.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{0.91}[0.91]?><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry rowsep="1" namest="col3" nameend="col4" align="center">Corrected </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Uncorrected</oasis:entry>
         <oasis:entry colname="col3">Locally</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M133" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> for</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">derived <inline-formula><mml:math id="M134" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M135" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Bham BAQS</oasis:entry>
         <oasis:entry colname="col2">3.5 (0.24)</oasis:entry>
         <oasis:entry colname="col3">1.3 (0.44)</oasis:entry>
         <oasis:entry colname="col4">0.5 (0.24)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Delhi</oasis:entry>
         <oasis:entry colname="col2">1.73 (0.33)</oasis:entry>
         <oasis:entry colname="col3">1.1 (0.60)</oasis:entry>
         <oasis:entry colname="col4">0.55 (0.60)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Bham Tyburn</oasis:entry>
         <oasis:entry colname="col2">2.5–3.5</oasis:entry>
         <oasis:entry colname="col3">0.98–1.33</oasis:entry>
         <oasis:entry colname="col4">0.72–0.98</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">(0.64–0.67)</oasis:entry>
         <oasis:entry colname="col3">(0.82–0.85)</oasis:entry>
         <oasis:entry colname="col4">(0.84–0.86)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

      <p id="d1e2672">We also observed that the ratio of OPC-N2 <inline-formula><mml:math id="M136" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> GRIMM concentrations was low at high
RH at Bham BAQS (Fig. 2c). The spread in OPC <inline-formula><mml:math id="M137" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> GRIMM ratios observed at high
RH at Bham BAQS is indicative of a diverse aerosol composition with
differing hygroscopicity over the 4 months. With respect to the calculated <inline-formula><mml:math id="M138" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value
for each month in Birmingham, very little variability (0.1–0.12) was found from
October to January which suggests that the bulk hygroscopicity of
the aerosols was consistent on average, although within a large range (as indicated by
the large spread in the OPC <inline-formula><mml:math id="M139" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> TEOM ratio in Fig. 2c).</p>
<sec id="Ch1.S3.SS3.SSS1">
  <label>3.3.1</label><title>Two-stage correction methodology for datasets with a wide range
of ambient RH values</title>
      <p id="d1e2710">For the Delhi dataset, the observed wide range of ambient RH values may have
affected the correction factor (Fig. 2), as particle hygroscopic growth
would be limited at low RH. Consequently, at low RH, defined as a RH less than
60 %, a linear correction factor may be more appropriate. From Fig. 2,
there appeared to be a linear relationship between the OPC-N2 and TEOM
PM<inline-formula><mml:math id="M140" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> measurements for RH values less 60 %. Therefore, we calculated a
linear correction factor for the OPC-N2 relative to the TEOM when the
ambient RH was less than 60 % (Fig. S4) and
applied it to the reported OPC-N2 PM<inline-formula><mml:math id="M141" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> concentrations. Using these
normalized OPC-N2 concentrations, the humidogram was replotted (Fig. 7), and
the corresponding <inline-formula><mml:math id="M142" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> fit was calculated (Fig. 7). With the above-mentioned normalized
OPC-N2 measurements, the <inline-formula><mml:math id="M143" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> line is also a better fit to the observed OPC <inline-formula><mml:math id="M144" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> TEOM
(Fig. 7) compared with using the uncorrected OPC-N2 data (Fig. 2). The
calculated <inline-formula><mml:math id="M145" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value from Fig. 7 was 0.45, which may be considered
more realistic considering the high sulfate and nitrate loading in Delhi
(Fig. 4). Using the <inline-formula><mml:math id="M146" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> from Fig. 7, we corrected the normalized
OPC-N2 PM<inline-formula><mml:math id="M147" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> concentrations using Eqs. (2) and (3). The time series of the
corrected OPC-N2 concentrations is shown in Fig. S5, and the application of this two-stage correction method
resulted in the OPC-N2 being in good agreement with the reference instrument
(slope of 1.1, <inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:msup><mml:mi>r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> of 0.61). However, we note that this is similar to
the agreement observed when the OPC-N2 was corrected without the two-stage
approach (Table 3). Nevertheless, the two-stage approach resulted in more
physically realistic humidograms and <inline-formula><mml:math id="M149" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values (Fig. 7) for Delhi, and this
approach may be more appropriate for locations that experience a wide range
of ambient RH values.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><?xmltex \currentcnt{7}?><label>Figure 7</label><caption><p id="d1e2796">Humidograms for Delhi using the normalized OPC-N2 PM<inline-formula><mml:math id="M150" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula>
mass concentrations with the corresponding <inline-formula><mml:math id="M151" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> fit.</p></caption>
            <?xmltex \igopts{width=128.037402pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f07.png"/>

          </fig>

</sec>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>The global applicability of correction factors</title>
      <p id="d1e2830">The results so far point to the need to establish the aerosol composition in order to
accurately apply a suitable correction factor, which is in agreement with previous
work (Di Antonio et al., 2018; Crilley et al., 2018). However, the determination
of the aerosol composition at the necessary time resolution would require
expensive co-located equipment to measure the aerosol composition (e.g. an
aerosol mass spectrometer), and this would somewhat negate the USPs of a low-cost
monitor. Di Antonio et al. (2018) suggested that the air mass origin (determined using HYSPLIT)
could provide compositional information in order to determine the
appropriate <inline-formula><mml:math id="M152" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value to use in the correction. Therefore, we examined
the long-term Birmingham dataset for times when the correction
factor that was applied over/under-corrected the OPC-N2 mass concentrations relative to
reference instrument. However, unlike Di Antonio et al. (2018), we could not
find any consistent patterns with respect to air mass origin and the
performance of the correction factor. Furthermore, the application of a
correction factor using this approach would require significant
post-processing time. This raises the question of whether the method would then remain a
“low-cost” option or not.</p>
      <p id="d1e2840">To remain a low-cost option, a simple correction that can be applied to the
OPC-N2 irrespective of aerosol composition changes is needed, although this
may decrease the accuracy of the correction factor. For many locations
around the world, ambient PM<inline-formula><mml:math id="M153" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations are measured
using gravimetric-based techniques (e.g. filters or TEOM) for regulatory
purposes. Consequently, we focused on<?pagebreak page1190?> developing a simple correction
factor using TEOM data as a reference. To explore if this was viable, we
plotted the OPC <inline-formula><mml:math id="M154" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> TEOM ratio for all sites where it was available (Bham Tyburn,
Delhi and Beijing) on one plot (Fig. 8). Note we used the two-stage correction
for the OPC-N2 measurements in Delhi, as described in Sect. 3.3.1,
for Fig. 8. We did not apply this correction to the Bham Tyburn data as the RH was
higher than 60 %.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8"><?xmltex \currentcnt{8}?><label>Figure 8</label><caption><p id="d1e2861">Humidogram using OPC-N2 data where there was dry
reference mass (TEOM), coloured by location. The resultant <inline-formula><mml:math id="M155" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> fit
(black) was generated using data from all three sites.</p></caption>
          <?xmltex \igopts{width=213.395669pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/1181/2020/amt-13-1181-2020-f08.png"/>

        </fig>

      <p id="d1e2878">From Fig. 8, a <inline-formula><mml:math id="M156" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value of 0.33 (assuming a uniform particle density of
1.65 for all sites) was calculated, which is slightly higher than the average of 0.3
suggested for continental regions (Pringle et al.,
2010). Consequently, we refer to the calculated <inline-formula><mml:math id="M157" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value from Fig. 8 as
global <inline-formula><mml:math id="M158" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>, but we note that it was calculated from three urban background sites on
two continents. We applied this <inline-formula><mml:math id="M159" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> (0.33) to correct the OPC-N2 data at
all sites as well as the average for continental regions (0.3), and the
results are summarized in Table 4. Variation in the <inline-formula><mml:math id="M160" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> values generally
resulted in changes in the slope, while the correlation co-efficient
remained similar. While the <inline-formula><mml:math id="M161" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value that was derived in situ resulted in a reasonable
correction of the OPC-N2 relative to the reference (<inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> %–30 %,
Table 4), using the <inline-formula><mml:math id="M163" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> from Fig. 8 (0.33) was comparable. Correcting
the datasets using the global <inline-formula><mml:math id="M164" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> of 0.33 resulted in an agreement with the
reference instruments of within 50 % at all sites, with the Beijing,
Delhi and some of the Bham Tyburn corrected OPC-N2 values being within 20 % of the
reference (Table 4). The only site with a notably poorer agreement using the
global compared with the in situ <inline-formula><mml:math id="M165" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value was Bham BAQS, and this may be because the
locally derived <inline-formula><mml:math id="M166" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value for the Bham BAQS measurements (0.1) was different from the other sites. This notwithstanding, we do note that using a
<inline-formula><mml:math id="M167" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value of 0.33 resulted in a significant improvement in accuracy compared
with the uncorrected OPC-N2-derived particle mass concentrations at Bham BAQS
(slope of 3.5, Table 3). Overall, when considering the most appropriate
correction or <inline-formula><mml:math id="M168" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value, the results from Table 3 suggest that a locally
derived <inline-formula><mml:math id="M169" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value, based on an in situ calibration with reference instrumentation,
is preferable. However, the global <inline-formula><mml:math id="M170" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value derived using data from the
three urban background locations in this study (0.33, Fig. 8) gave
comparable results to the correction that was derived in situ (Table 4). Therefore, this
suggests that using this <inline-formula><mml:math id="M171" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value or a suitable value from the literature for
urban background sites may be acceptable should there be no reference
instruments available for calibration.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e3001">Comparison of the performance of the local and global correction
factors for correcting OPC-N2 measurements using the Crilley et al. (2018) method: shown
as a slope relative to the reference instrument with the r<inline-formula><mml:math id="M172" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula> values given
in parentheses. Intercepts were not constrained to zero.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{0.91}[0.91]?><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Site</oasis:entry>
         <oasis:entry colname="col2">Correction</oasis:entry>
         <oasis:entry colname="col3">Global</oasis:entry>
         <oasis:entry colname="col4">Continental</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">derived</oasis:entry>
         <oasis:entry colname="col3">(<inline-formula><mml:math id="M173" display="inline"><mml:mrow><mml:mi mathvariant="italic">κ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.33</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col4">average</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">in situ</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">(<inline-formula><mml:math id="M174" display="inline"><mml:mrow><mml:mi mathvariant="italic">κ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.3</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Bham</oasis:entry>
         <oasis:entry colname="col2">0.98–1.33</oasis:entry>
         <oasis:entry colname="col3">1.1–1.5</oasis:entry>
         <oasis:entry colname="col4">1.2–1.6</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Tyburn</oasis:entry>
         <oasis:entry colname="col2">(0.82–0.85)</oasis:entry>
         <oasis:entry colname="col3">(0.82–0.85)</oasis:entry>
         <oasis:entry colname="col4">(0.82–0.85)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Delhi</oasis:entry>
         <oasis:entry colname="col2">1.1 (0.60)</oasis:entry>
         <oasis:entry colname="col3">0.80 (0.61)</oasis:entry>
         <oasis:entry colname="col4">0.84 (0.61)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Bham BAQS</oasis:entry>
         <oasis:entry colname="col2">0.96 (0.42)</oasis:entry>
         <oasis:entry colname="col3">0.54 (0.45)</oasis:entry>
         <oasis:entry colname="col4">0.57 (0.45)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Beijing</oasis:entry>
         <oasis:entry colname="col2">1.35 (0.87)</oasis:entry>
         <oasis:entry colname="col3">0.85 (0.85)</oasis:entry>
         <oasis:entry colname="col4">0.87 (0.85)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e3183">Recent work has demonstrated that aerosol hygroscopicity is likely the key
parameter to consider when correcting particle mass concentrations derived using
a low-cost OPC, particularly at high ambient RH. Consequently, correction
factors have been developed that apply <inline-formula><mml:math id="M175" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula>-Köhler theory to
correct for the influence of water uptake by hygroscopic aerosols. In the
current work, we explored the performance of this correction factor using
datasets from reference instruments and low-cost OPCs (OPC-N2) co-located
in environments that had differing aerosol compositions, particle loads and
ambient RH values. We observed evidence that the enhanced high concentrations
reported by the OPC-N2 relative to reference instrumentation during periods
of high RH were related to the amount of hygroscopic aerosols (sulfate and
nitrate) and RH, which would be expected if the bulk aerosol hygroscopicity was driving
this response. This was most clearly observed during measurements in
volcanic plumes in Nicaragua, where the observed humidogram closely
resembled the calculated pure sulfuric acid humidogram. This agreement
between the model and measurements strongly points to particle hygroscopic
growth driving the high particle mass concentrations observed by the OPC-N2
during times of high ambient RH.</p>
      <?pagebreak page1191?><p id="d1e3193">The results indicate that the particle mass concentration measurements
reported by low-cost OPCs during periods of high RH (<inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:mi mathvariant="italic">&gt;</mml:mi><mml:mn mathvariant="normal">60</mml:mn></mml:mrow></mml:math></inline-formula> %)
need to be corrected for aerosol hygroscopic growth. We employed the
correction factor method outlined in Crilley et al. (2018) to account for
this and observed corrected OPC-N2 PM<inline-formula><mml:math id="M177" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations to be
within 33 % of the reference at all sites. The choice of the <inline-formula><mml:math id="M178" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value applied
was found to be critical. The results from the current work indicate that a
<inline-formula><mml:math id="M179" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value derived in situ (using suitable reference instrumentation) leads to the
most accurate correction relative to co-located reference instruments. The
<inline-formula><mml:math id="M180" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value derived in situ would also likely be dependent on the time of year if
there were any local seasonality to the bulk aerosol composition, and this
would need to be considered when determining appropriate calibration
procedures.</p>
      <p id="d1e3236">An average <inline-formula><mml:math id="M181" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value of 0.33 was calculated using measurements from three
urban locations around the globe (Beijing, Birmingham and Delhi). Applying
this global <inline-formula><mml:math id="M182" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value in the correction factor notably improved the reported
OPC-N2 PM<inline-formula><mml:math id="M183" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations, relative to the uncorrected measurements, to within
50 % of reference measurements at all sites. Therefore, for areas where
suitable reference instrumentation for developing a local correction factor
is lacking, using a literature <inline-formula><mml:math id="M184" display="inline"><mml:mi mathvariant="italic">κ</mml:mi></mml:math></inline-formula> value can result in a reasonable
correction. For locations with low levels of hygroscopic aerosols and low RH
(such as Nairobi), a simple calibration against gravimetric measurements
(using suitable reference instrumentation) would likely be sufficient.
Whilst this study specifically generated correction factors for the Alphasense
OPC-N2 sensor, the calibration methodology developed is likely amenable to
other low-cost PM sensors.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e3274">The data use in this study are available upon request.</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e3277">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-13-1181-2020-supplement" xlink:title="pdf">https://doi.org/10.5194/amt-13-1181-2020-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e3286">LRC and FDP conceived the study. LRC, AS, LJK and FDP performed the data
analysis. LRC, LJK, MDS, MSA, SY, WF, PF, YS, SG, JSA, AS, RCWW, EI, DN, MG and
FDP contributed to data investigation and curation. LRC wrote the original
draft of the paper, and all co-authors contributed to reviewing and editing the paper.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e3292">The authors declare that they have no conflict of interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e3298">We acknowledge Zifa Wang and Jie Li from IAP for hosting
the APHH-Beijing campaign at IAP. We thank Zongbo Shi, Di Liu, Roy Harrison
and Tuan Vu from the University of Birmingham; Liangfang Wei, Hong Ren,
Qiaorong Xie, Wanyu Zhao, Linjie Li, Ping Li, Shengjie Hou and Qingqing Wang
from IAP; Rachel Dunmore and James Lee from the University of York; Kebin He
and Xiaoting Cheng from Tsinghua University; and James Allan and Hugh Coe
from the University of Manchester for providing logistic and scientific
support for the field campaigns. We gratefully acknowledge Mukesh Khare, Isha
Kanna, Saif Khan, Rulan Verma and Gazala Habib from IIT Delhi for
hosting and facilitating the measurements at IIT Delhi. Scientific research support from the International Science Programme in Sweden to
the Institute of Nuclear Science and Technology at the University of
Nairobi was appreciated.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e3303">The APHH-Beijing project was funded by the
UK Natural Environment Research Council (NERC), the Medical Research Council and the
Natural Science Foundation of China within the framework of the Newton Innovation
Fund (grant nos. NE/N007190/1 and NE/N007077/1). Leigh R. Crilley, Louisa J. Kramer, Mohammed S. Alam and
William J. Bloss acknowledge funding for ASAP-Delhi as part of the APHH-India project by
the UK Natural Environment Research Council (NERC), the Indian Ministry of Earth
Sciences (MoES) and the Department for Biotechnology (DBT; grant no. NE/P016499/1). The work in the UK was funded via a NERC grant (Quantification of Utility
of Atmospheric Network Technologies, QUANT, grant no. NE/T001968/1). The work in Kenya was funded via an EPSRC grant (Global Challenges Research
Fund grant no. IS2016), the Royal Society and Royal Society of Chemistry International
Exchanges Award (grant no. IE170267) and DFID via the East African Research Fund
(EARF) “A Systems Approach to Air Pollution (ASAP) East Africa” grant. The work in Nicaragua was funded by the GCRF UNRESP project (grant nos. NE/P015271/1 and NE/R009465/1).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e3309">This paper was edited by Charles Brock and reviewed by Don Collins and one anonymous referee.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><?label 1?><mixed-citation>
Alam, M. S., Keyte, I. J., Yin, J., Stark, C., Jones, A. M., and Harrison, R. M: Diurnal variability of polycyclic aromatic compound (PAC)
concentrations: relationship with meteorological conditions and inferred
sources, Atmos. Environ., 122, 427–438, 2015.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><?label 1?><mixed-citation>Borrego, C., Costa, A. M., Ginja, J., Amorim, M., Coutinho, M., Karatzas,
K., Sioumis, T., Katsifarakis, N., Konstantinidis, K., De Vito, S.,
Esposito, E., Smith, P., André, N., Gérard, P., Francis, L. A.,
Castell, N., Schneider, P., Viana, M., Minguillón, M. C., Reimringer,
W., Otjes, R. P., von Sicard, O., Pohle, R., Elen, B., Suriano, D., Pfister,
V., Prato, M., Dipinto, S., and Penza, M.: Assessment of air quality
microsensors versus reference methods: The EuNetAir joint exercise,
Atmos. Environ., 147, 246–263, <ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2016.09.050" ext-link-type="DOI">10.1016/j.atmosenv.2016.09.050</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><?label 1?><mixed-citation>Castell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain,
B., Broday, D., and Bartonova, A.: Can commercial low-cost sensor platforms
contribute to air quality monitoring and exposure estimates?, Environ.
Int., 99, 293–302, <ext-link xlink:href="https://doi.org/10.1016/j.envint.2016.12.007" ext-link-type="DOI">10.1016/j.envint.2016.12.007</ext-link>,
2017.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><?label 1?><mixed-citation>Cohen, A. J., Ross Anderson, H., Ostro, B., Pandey, K. D., Krzyzanowski, M.,
Künzli, N., Gutschmidt, K., Pope, A., Romieu, I., Samet, J. M., and
Smith, K.: The Global Burden of Disease Due to Outdoor Air Pollution,
J. Toxicol. Env. Health A, 68, 1301–1307,
<ext-link xlink:href="https://doi.org/10.1080/15287390590936166" ext-link-type="DOI">10.1080/15287390590936166</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><?label 1?><mixed-citation>Crilley, L. R., Shaw, M., Pound, R., Kramer, L. J., Price, R., Young, S., Lewis, A. C., and Pope, F. D.: Evaluation of a low-cost optical particle counter (Alphasense OPC-N2) for ambient air monitoring, Atmos. Meas. Tech., 11, 709–720, <ext-link xlink:href="https://doi.org/10.5194/amt-11-709-2018" ext-link-type="DOI">10.5194/amt-11-709-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><?label 1?><mixed-citation>de Nazelle, A., Bode, O., and Orjuela, J. P.: Comparison of air pollution
exposures in active vs. passive travel modes in European cities: A
quantitative review, Environ. Int., 99, 151–160,
<ext-link xlink:href="https://doi.org/10.1016/j.envint.2016.12.023" ext-link-type="DOI">10.1016/j.envint.2016.12.023</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><?label 1?><mixed-citation>Di Antonio, A., Popoola, O., Ouyang, B., Saffell, J., and Jones, R.:
Developing a Relative Humidity Correction for Low-Cost Sensors Measuring
Ambient Particulate Matter, Sensors, 18, 2790, <ext-link xlink:href="https://doi.org/10.3390/s18092790" ext-link-type="DOI">10.3390/s18092790</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><?label 1?><mixed-citation>Gaita, S. M., Boman, J., Gatari, M. J., Pettersson, J. B. C., and Janhäll, S.: Source apportionment and seasonal variation of PM<inline-formula><mml:math id="M185" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:math></inline-formula> in a Sub-Saharan African city: Nairobi, Kenya, Atmos. Chem. Phys., 14, 9977–9991, https://doi.org/10.5194/acp-14-9977-2014, 2014.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><?label 1?><mixed-citation>Gani, S., Bhandari, S., Seraj, S., Wang, D. S., Patel, K., Soni, P., Arub, Z., Habib, G., Hildebrandt Ruiz, L., and Apte, J. S.: Submicron aerosol composition in the world's most polluted megacity: the Delhi Aerosol Supersite study, Atmos. Chem. Phys., 19, 6843–6859, <ext-link xlink:href="https://doi.org/10.5194/acp-19-6843-2019" ext-link-type="DOI">10.5194/acp-19-6843-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><?label 1?><mixed-citation>
Gibson, E. R., Hudson, P. K., and Grassian, V. H:
Physicochemical properties of nitrate aerosols: Implications for the
atmosphere, J. Phys. Chem. A., 110, 11785–11799, 2006.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><?label 1?><mixed-citation>Grover, B. D., Eatough, N. L., Eatough, D. J., Chow, J. C., Watson, J. G.,
Ambs, J. L., Meyer, M. B., Hopke, P. K., Al-Horr, R., Later, D. W., and
Wilson, W. E.: Measurement of Both Nonvolatile and Semi-Volatile Fractions
of Fine Particulate Matter in Fresno, CA, Aerosol. Sci. Tech.,
40, 811–826, <ext-link xlink:href="https://doi.org/10.1080/02786820600615071" ext-link-type="DOI">10.1080/02786820600615071</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><?label 1?><mixed-citation>Hagan, D. H., Tolmie, A., and Trochim, J.: py-opc: operate the Alphasense
OPC-N2 from a raspberry pi or other popular microcontrollers/microcomputers,
Journal of Open Source Software, 3, 782, <ext-link xlink:href="https://doi.org/10.21105/joss.00782" ext-link-type="DOI">10.21105/joss.00782</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><?label 1?><mixed-citation>
Hu, D., Qiao, L., Chen, J., Ye, X., Yang, X., Cheng, T., and Fang, W.:
Hygroscopicity of inorganic aerosols: size and relative humidity effects on
the growth factor, Aerosol. Air. Qual. Res., 10, 255–264, 2010.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><?label 1?><mixed-citation>Jayaratne, R., Liu, X., Thai, P., Dunbabin, M., and Morawska, L.: The influence of humidity on the performance of a low-cost air particle mass sensor and the effect of atmospheric fog, Atmos. Meas. Tech., 11, 4883–4890, <ext-link xlink:href="https://doi.org/10.5194/amt-11-4883-2018" ext-link-type="DOI">10.5194/amt-11-4883-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><?label 1?><mixed-citation>Landrigan, P. J., Fuller, R., Acosta, N. J. R., Adeyi, O., Arnold, R., Basu,
N., Baldé, A. B., Bertollini, R., Bose-O'Reilly, S., Boufford, J. I.,
Breysse, P. N., Chiles, T., Mahidol, C., Coll-Seck, A. M., Cropper, M. L.,
Fobil, J., Fuster, V., Greenstone, M., Haines, A., Hanrahan, D., Hunter, D.,
Khare, M., Krupnick, A., Lanphear, B., Lohani, B., Martin, K., Mathiasen, K.
V., McTeer, M. A., Murray, C. J. L., Ndahimananjara, J. D., Perera, F.,
Potočnik, J., Preker, A. S., Ramesh, J., Rockström, J., Salinas, C.,
Samson, L. D., Sandilya, K., Sly, P. D., Smith, K. R., Steiner, A., Stewart,
R. B., Suk, W. A., van Schayck, O. C. P., Yadama, G. N., Yumkella, K., and
Zhong, M.: The Lancet Commission on pollution and health, The Lancet, 391,
462–512, <ext-link xlink:href="https://doi.org/10.1016/S0140-6736(17)32345-0" ext-link-type="DOI">10.1016/S0140-6736(17)32345-0</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><?label 1?><mixed-citation>
Lewis, A., Peltier, W. R., and von Schneidemesser, E.: Low-cost sensors for
the measurement of atmospheric composition: Overview of topic and future
applications, Research Report, World Meteorological Organization (WMO), Geneva, Switzerland, 2018.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><?label 1?><mixed-citation>Lewis, A. C., Lee, J. D., Edwards, P. M., Shaw, M. D., Evans, M. J., Moller,
S. J., Smith, K. R., Buckley, J. W., Ellis, M., Gillot, S. R., and White,
A.: Evaluating the performance of low cost chemical sensors for air
pollution research, Faraday Discuss., 189, 85–103, <ext-link xlink:href="https://doi.org/10.1039/C5FD00201J" ext-link-type="DOI">10.1039/C5FD00201J</ext-link>,
2016.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><?label 1?><mixed-citation>Mead, M. I., Popoola, O. A. M., Stewart, G. B., Landshoff, P., Calleja, M.,
Hayes, M., Baldovi, J. J., McLeod, M. W., Hodgson, T. F., Dicks, J., Lewis,
A., Cohen, J., Baron, R., Saffell, J. R., and Jones, R. L.: The use of
electrochemical sensors for monitoring urban air quality in low-cost,
high-density networks, Atmos. Environ., 70, 186–203,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2012.11.060" ext-link-type="DOI">10.1016/j.atmosenv.2012.11.060</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><?label 1?><mixed-citation>Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova,
A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., Gao, J., Hagler, G.
S. W., Jayaratne, R., Kumar, P., Lau, A. K. H., Louie, P. K. K., Mazaheri,
M., Ning, Z., Motta, N., Mullins, B., Rahman, M. M., Ristovski, Z., Shafiei,
M., Tjondronegoro, D., Westerdahl, D., and Williams, R.: Applications of
low-cost sensing technologies for air quality monitoring and exposure
assessment: How far have they gone?, Environ. Int., 116,
286–299, <ext-link xlink:href="https://doi.org/10.1016/j.envint.2018.04.018" ext-link-type="DOI">10.1016/j.envint.2018.04.018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><?label 1?><mixed-citation>Petters, M. D. and Kreidenweis, S. M.: A single parameter representation of hygroscopic growth and cloud condensation nucleus activity, Atmos. Chem. Phys., 7, 1961–1971, <ext-link xlink:href="https://doi.org/10.5194/acp-7-1961-2007" ext-link-type="DOI">10.5194/acp-7-1961-2007</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><?label 1?><mixed-citation>Pope, F. D.: Pollen grains are efficient cloud condensation nuclei,
Environ. Res. Lett., 5, 044015, <ext-link xlink:href="https://doi.org/10.1088/1748-9326/5/4/044015" ext-link-type="DOI">10.1088/1748-9326/5/4/044015</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><?label 1?><mixed-citation>Pope, F. D., Dennis-Smither, B. J., Griffiths, P. T., Clegg, S. L., and Cox,
R. A.: Studies of Single Aerosol Particles Containing Malonic Acid, Glutaric
Acid, and Their Mixtures with Sodium Chloride. I. Hygroscopic Growth, J. Phys. Chem. A, 114, 5335–5341, <ext-link xlink:href="https://doi.org/10.1021/jp100059k" ext-link-type="DOI">10.1021/jp100059k</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><?label 1?><mixed-citation>
Pope, F. D., Gatari, M., Ng'ang'a, D., Poynter, A., and Blake, R.: Airborne particulate matter monitoring in Kenya using calibrated low-cost sensors, Atmos. Chem. Phys., 18, 15403–15418, https://doi.org/10.5194/acp-18-15403-2018, 2018.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><?label 1?><mixed-citation>Popoola, O. A. M., Stewart, G. B., Mead, M. I., and Jones, R. L.:
Development of a baseline-temperature correction methodology for
electrochemical sensors and its implications for long-term stability,
Atmos. Environ., 147, 330–343,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2016.10.024" ext-link-type="DOI">10.1016/j.atmosenv.2016.10.024</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><?label 1?><mixed-citation>Pringle, K. J., Tost, H., Pozzer, A., Pöschl, U., and Lelieveld, J.: Global distribution of the effective aerosol hygroscopicity parameter for CCN activation, Atmos. Chem. Phys., 10, 5241–5255, <ext-link xlink:href="https://doi.org/10.5194/acp-10-5241-2010" ext-link-type="DOI">10.5194/acp-10-5241-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><?label 1?><mixed-citation>Sarangi, B., Aggarwal, S. G., Sinha, D., and Gupta, P. K.: Aerosol effective density measurement using scanning mobility particle sizer and quartz crystal microbalance with th<?pagebreak page1193?>e estimation of involved uncertainty, Atmos. Meas. Tech., 9, 859–875, <ext-link xlink:href="https://doi.org/10.5194/amt-9-859-2016" ext-link-type="DOI">10.5194/amt-9-859-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><?label 1?><mixed-citation>Shehab, M. A. and Pope, F. D.: Effects of short-term exposure to
particulate matter air pollution on cognitive performance, Sci. Rep., 9, 8237, <ext-link xlink:href="https://doi.org/10.1038/s41598-019-44561-0" ext-link-type="DOI">10.1038/s41598-019-44561-0</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><?label 1?><mixed-citation>Shi, Z., Vu, T., Kotthaus, S., Harrison, R. M., Grimmond, S., Yue, S., Zhu, T., Lee, J., Han, Y., Demuzere, M., Dunmore, R. E., Ren, L., Liu, D., Wang, Y., Wild, O., Allan, J., Acton, W. J., Barlow, J., Barratt, B., Beddows, D., Bloss, W. J., Calzolai, G., Carruthers, D., Carslaw, D. C., Chan, Q., Chatzidiakou, L., Chen, Y., Crilley, L., Coe, H., Dai, T., Doherty, R., Duan, F., Fu, P., Ge, B., Ge, M., Guan, D., Hamilton, J. F., He, K., Heal, M., Heard, D., Hewitt, C. N., Hollaway, M., Hu, M., Ji, D., Jiang, X., Jones, R., Kalberer, M., Kelly, F. J., Kramer, L., Langford, B., Lin, C., Lewis, A. C., Li, J., Li, W., Liu, H., Liu, J., Loh, M., Lu, K., Lucarelli, F., Mann, G., McFiggans, G., Miller, M. R., Mills, G., Monk, P., Nemitz, E., O'Connor, F., Ouyang, B., Palmer, P. I., Percival, C., Popoola, O., Reeves, C., Rickard, A. R., Shao, L., Shi, G., Spracklen, D., Stevenson, D., Sun, Y., Sun, Z., Tao, S., Tong, S., Wang, Q., Wang, W., Wang, X., Wang, X., Wang, Z., Wei, L., Whalley, L., Wu, X., Wu, Z., Xie, P., Yang, F., Zhang, Q., Zhang, Y., Zhang, Y., and Zheng, M.: Introduction to the special issue “In-depth study of air pollution sources and processes within Beijing and its surrounding region (APHH-Beijing)”, Atmos. Chem. Phys., 19, 7519–7546, <ext-link xlink:href="https://doi.org/10.5194/acp-19-7519-2019" ext-link-type="DOI">10.5194/acp-19-7519-2019</ext-link>, 2019.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib29"><label>29</label><?label 1?><mixed-citation>
Smith, K. R., Edwards, P., Evans, M. J., Lee, J. D., Shaw, M. D., Squires,
F. A., and Lewis, A.: Clustering approaches to improve the performance of
low cost air pollution sensors, Faraday Discuss., 200, 1–15, 2017.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><?label 1?><mixed-citation>Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R.
W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., and Preuss,
P. W.: The Changing Paradigm of Air Pollution Monitoring, Environ. Sci. Technol., 47, 11369–11377, <ext-link xlink:href="https://doi.org/10.1021/es4022602" ext-link-type="DOI">10.1021/es4022602</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><?label 1?><mixed-citation>
Sousan, S., Koehler, K., Hallett, L., and Peters, T. M.: Evaluation of the
Alphasense optical particle counter (OPC-N2) and the Grimm portable aerosol
spectrometer (PAS-1.108), Aerosol. Sci. Tech., 50, 1352–1365,
2016.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><?label 1?><mixed-citation>Wexler, A. S. and Clegg, S. L.: Atmospheric aerosol models for systems
including the ions <inline-formula><mml:math id="M186" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">H</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M187" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M188" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">Na</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">4</mml:mn><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>-</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M190" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>-</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M191" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">Cl</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">Br</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, and
<inline-formula><mml:math id="M193" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, 107, J. Geophys. Res.-Atmos., 107, ACH 14-11–ACH 14-14, <ext-link xlink:href="https://doi.org/10.1029/2001JD000451" ext-link-type="DOI">10.1029/2001JD000451</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><?label 1?><mixed-citation>Yin, J., Harrison, R. M., Chen, Q., Rutter, A., and Schauer, J. J.: Source
apportionment of fine particles at urban background and rural sites in the
UK atmosphere, Atmos. Environ., 44, 841–851,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2009.11.026" ext-link-type="DOI">10.1016/j.atmosenv.2009.11.026</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><?label 1?><mixed-citation>Xu, W., Sun, Y., Wang, Q., Zhao, J., Wang, J., Ge, X., Xie, C., Zhou, W.,
Du, W., Li, J., Fu, P., Wang, Z., Worsnop, D. R., and Coe, H.: Changes in
Aerosol Chemistry from 2014 to 2016 in Winter in Beijing: Insights from High
Resolution Aerosol Mass Spectrometry, J. Geophys. Res., 124, 1132–1147,
<ext-link xlink:href="https://doi.org/10.1029/2018JD029245" ext-link-type="DOI">10.1029/2018JD029245</ext-link>, 2019.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Effect of aerosol composition on the performance of low-cost optical particle counter correction factors</article-title-html>
<abstract-html><p>There is considerable interest in using low-cost optical
particle counters (OPCs) to supplement existing routine air quality networks
that monitor particle mass concentrations. In order to do this, low-cost OPC
data need to be comparable with particle mass reference
instrumentation; however, there is currently no widely agreed upon methodology to accomplish this. Aerosol
hygroscopicity is known to be a key parameter to consider when correcting
particle mass concentrations derived from low-cost OPCs, particularly at
high ambient relative humidity (RH). Correction factors have been developed
that apply <i>κ</i>-Köhler theory to correct for the influence of water
uptake by hygroscopic aerosols. We have used datasets of co-located
reference particle measurements and low-cost OPC (OPC-N2, Alphasense) measurements, collected in four cities on three continents, to explore the performance of
this correction factor. We provide evidence that the elevated particle mass
concentrations, reported by the low-cost OPC relative to reference
instrumentation, are due to bulk aerosol hygroscopicity under different RH
conditions, which is determined by aerosol composition and, in particular, the
levels of hygroscopic aerosols (sulfate and nitrate). We exploit
measurements made in volcanic plumes in Nicaragua, which are predominantly
composed of sulfate aerosol, as a natural experiment to demonstrate this
behaviour in the ambient atmosphere; the observed humidogram from these measurements closely
resembles the calculated pure sulfuric acid humidogram. The results
indicate that the particle mass concentrations derived from low-cost OPCs
during periods of high RH (<i>&gt;</i>60&thinsp;%) need to be corrected for
aerosol hygroscopic growth. We employed a correction factor based on <i>κ</i>-Köhler theory and observed that the corrected OPC-N2 PM<sub>2.5</sub> mass
concentrations were within 33&thinsp;% of reference measurements at all sites.
The results indicated that a <i>κ</i> value derived in situ (using suitable reference
instrumentation) would lead to the most accurate correction relative to
co-located reference instruments. Applying a <i>κ</i> values from the literature in the
correction factor also resulted in improved OPC-N2 performance, with the measurements being within 50&thinsp;% of the reference values. Therefore, for areas where suitable reference
instrumentation for developing a local correction factor is lacking, using a
literature <i>κ</i> value can result in a reasonable correction. For
locations with low levels of hygroscopic aerosols and low RH values, a simple
calibration against gravimetric measurements (using suitable reference
instrumentation) would likely be sufficient. Whilst this study generated
correction factors specific for the Alphasense OPC-N2 sensor, the
calibration methodology developed is likely amenable to other low-cost PM
sensors.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Alam, M. S., Keyte, I. J., Yin, J., Stark, C., Jones, A. M., and Harrison, R. M: Diurnal variability of polycyclic aromatic compound (PAC)
concentrations: relationship with meteorological conditions and inferred
sources, Atmos. Environ., 122, 427–438, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Borrego, C., Costa, A. M., Ginja, J., Amorim, M., Coutinho, M., Karatzas,
K., Sioumis, T., Katsifarakis, N., Konstantinidis, K., De Vito, S.,
Esposito, E., Smith, P., André, N., Gérard, P., Francis, L. A.,
Castell, N., Schneider, P., Viana, M., Minguillón, M. C., Reimringer,
W., Otjes, R. P., von Sicard, O., Pohle, R., Elen, B., Suriano, D., Pfister,
V., Prato, M., Dipinto, S., and Penza, M.: Assessment of air quality
microsensors versus reference methods: The EuNetAir joint exercise,
Atmos. Environ., 147, 246–263, <a href="https://doi.org/10.1016/j.atmosenv.2016.09.050" target="_blank">https://doi.org/10.1016/j.atmosenv.2016.09.050</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Castell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain,
B., Broday, D., and Bartonova, A.: Can commercial low-cost sensor platforms
contribute to air quality monitoring and exposure estimates?, Environ.
Int., 99, 293–302, <a href="https://doi.org/10.1016/j.envint.2016.12.007" target="_blank">https://doi.org/10.1016/j.envint.2016.12.007</a>,
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Cohen, A. J., Ross Anderson, H., Ostro, B., Pandey, K. D., Krzyzanowski, M.,
Künzli, N., Gutschmidt, K., Pope, A., Romieu, I., Samet, J. M., and
Smith, K.: The Global Burden of Disease Due to Outdoor Air Pollution,
J. Toxicol. Env. Health A, 68, 1301–1307,
<a href="https://doi.org/10.1080/15287390590936166" target="_blank">https://doi.org/10.1080/15287390590936166</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Crilley, L. R., Shaw, M., Pound, R., Kramer, L. J., Price, R., Young, S., Lewis, A. C., and Pope, F. D.: Evaluation of a low-cost optical particle counter (Alphasense OPC-N2) for ambient air monitoring, Atmos. Meas. Tech., 11, 709–720, <a href="https://doi.org/10.5194/amt-11-709-2018" target="_blank">https://doi.org/10.5194/amt-11-709-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
de Nazelle, A., Bode, O., and Orjuela, J. P.: Comparison of air pollution
exposures in active vs. passive travel modes in European cities: A
quantitative review, Environ. Int., 99, 151–160,
<a href="https://doi.org/10.1016/j.envint.2016.12.023" target="_blank">https://doi.org/10.1016/j.envint.2016.12.023</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Di Antonio, A., Popoola, O., Ouyang, B., Saffell, J., and Jones, R.:
Developing a Relative Humidity Correction for Low-Cost Sensors Measuring
Ambient Particulate Matter, Sensors, 18, 2790, <a href="https://doi.org/10.3390/s18092790" target="_blank">https://doi.org/10.3390/s18092790</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Gaita, S. M., Boman, J., Gatari, M. J., Pettersson, J. B. C., and Janhäll, S.: Source apportionment and seasonal variation of PM<sub>2.5</sub> in a Sub-Saharan African city: Nairobi, Kenya, Atmos. Chem. Phys., 14, 9977–9991, https://doi.org/10.5194/acp-14-9977-2014, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Gani, S., Bhandari, S., Seraj, S., Wang, D. S., Patel, K., Soni, P., Arub, Z., Habib, G., Hildebrandt Ruiz, L., and Apte, J. S.: Submicron aerosol composition in the world's most polluted megacity: the Delhi Aerosol Supersite study, Atmos. Chem. Phys., 19, 6843–6859, <a href="https://doi.org/10.5194/acp-19-6843-2019" target="_blank">https://doi.org/10.5194/acp-19-6843-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Gibson, E. R., Hudson, P. K., and Grassian, V. H:
Physicochemical properties of nitrate aerosols: Implications for the
atmosphere, J. Phys. Chem. A., 110, 11785–11799, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Grover, B. D., Eatough, N. L., Eatough, D. J., Chow, J. C., Watson, J. G.,
Ambs, J. L., Meyer, M. B., Hopke, P. K., Al-Horr, R., Later, D. W., and
Wilson, W. E.: Measurement of Both Nonvolatile and Semi-Volatile Fractions
of Fine Particulate Matter in Fresno, CA, Aerosol. Sci. Tech.,
40, 811–826, <a href="https://doi.org/10.1080/02786820600615071" target="_blank">https://doi.org/10.1080/02786820600615071</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Hagan, D. H., Tolmie, A., and Trochim, J.: py-opc: operate the Alphasense
OPC-N2 from a raspberry pi or other popular microcontrollers/microcomputers,
Journal of Open Source Software, 3, 782, <a href="https://doi.org/10.21105/joss.00782" target="_blank">https://doi.org/10.21105/joss.00782</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Hu, D., Qiao, L., Chen, J., Ye, X., Yang, X., Cheng, T., and Fang, W.:
Hygroscopicity of inorganic aerosols: size and relative humidity effects on
the growth factor, Aerosol. Air. Qual. Res., 10, 255–264, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Jayaratne, R., Liu, X., Thai, P., Dunbabin, M., and Morawska, L.: The influence of humidity on the performance of a low-cost air particle mass sensor and the effect of atmospheric fog, Atmos. Meas. Tech., 11, 4883–4890, <a href="https://doi.org/10.5194/amt-11-4883-2018" target="_blank">https://doi.org/10.5194/amt-11-4883-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Landrigan, P. J., Fuller, R., Acosta, N. J. R., Adeyi, O., Arnold, R., Basu,
N., Baldé, A. B., Bertollini, R., Bose-O'Reilly, S., Boufford, J. I.,
Breysse, P. N., Chiles, T., Mahidol, C., Coll-Seck, A. M., Cropper, M. L.,
Fobil, J., Fuster, V., Greenstone, M., Haines, A., Hanrahan, D., Hunter, D.,
Khare, M., Krupnick, A., Lanphear, B., Lohani, B., Martin, K., Mathiasen, K.
V., McTeer, M. A., Murray, C. J. L., Ndahimananjara, J. D., Perera, F.,
Potočnik, J., Preker, A. S., Ramesh, J., Rockström, J., Salinas, C.,
Samson, L. D., Sandilya, K., Sly, P. D., Smith, K. R., Steiner, A., Stewart,
R. B., Suk, W. A., van Schayck, O. C. P., Yadama, G. N., Yumkella, K., and
Zhong, M.: The Lancet Commission on pollution and health, The Lancet, 391,
462–512, <a href="https://doi.org/10.1016/S0140-6736(17)32345-0" target="_blank">https://doi.org/10.1016/S0140-6736(17)32345-0</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Lewis, A., Peltier, W. R., and von Schneidemesser, E.: Low-cost sensors for
the measurement of atmospheric composition: Overview of topic and future
applications, Research Report, World Meteorological Organization (WMO), Geneva, Switzerland, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Lewis, A. C., Lee, J. D., Edwards, P. M., Shaw, M. D., Evans, M. J., Moller,
S. J., Smith, K. R., Buckley, J. W., Ellis, M., Gillot, S. R., and White,
A.: Evaluating the performance of low cost chemical sensors for air
pollution research, Faraday Discuss., 189, 85–103, <a href="https://doi.org/10.1039/C5FD00201J" target="_blank">https://doi.org/10.1039/C5FD00201J</a>,
2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Mead, M. I., Popoola, O. A. M., Stewart, G. B., Landshoff, P., Calleja, M.,
Hayes, M., Baldovi, J. J., McLeod, M. W., Hodgson, T. F., Dicks, J., Lewis,
A., Cohen, J., Baron, R., Saffell, J. R., and Jones, R. L.: The use of
electrochemical sensors for monitoring urban air quality in low-cost,
high-density networks, Atmos. Environ., 70, 186–203,
<a href="https://doi.org/10.1016/j.atmosenv.2012.11.060" target="_blank">https://doi.org/10.1016/j.atmosenv.2012.11.060</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova,
A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., Gao, J., Hagler, G.
S. W., Jayaratne, R., Kumar, P., Lau, A. K. H., Louie, P. K. K., Mazaheri,
M., Ning, Z., Motta, N., Mullins, B., Rahman, M. M., Ristovski, Z., Shafiei,
M., Tjondronegoro, D., Westerdahl, D., and Williams, R.: Applications of
low-cost sensing technologies for air quality monitoring and exposure
assessment: How far have they gone?, Environ. Int., 116,
286–299, <a href="https://doi.org/10.1016/j.envint.2018.04.018" target="_blank">https://doi.org/10.1016/j.envint.2018.04.018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Petters, M. D. and Kreidenweis, S. M.: A single parameter representation of hygroscopic growth and cloud condensation nucleus activity, Atmos. Chem. Phys., 7, 1961–1971, <a href="https://doi.org/10.5194/acp-7-1961-2007" target="_blank">https://doi.org/10.5194/acp-7-1961-2007</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Pope, F. D.: Pollen grains are efficient cloud condensation nuclei,
Environ. Res. Lett., 5, 044015, <a href="https://doi.org/10.1088/1748-9326/5/4/044015" target="_blank">https://doi.org/10.1088/1748-9326/5/4/044015</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Pope, F. D., Dennis-Smither, B. J., Griffiths, P. T., Clegg, S. L., and Cox,
R. A.: Studies of Single Aerosol Particles Containing Malonic Acid, Glutaric
Acid, and Their Mixtures with Sodium Chloride. I. Hygroscopic Growth, J. Phys. Chem. A, 114, 5335–5341, <a href="https://doi.org/10.1021/jp100059k" target="_blank">https://doi.org/10.1021/jp100059k</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Pope, F. D., Gatari, M., Ng'ang'a, D., Poynter, A., and Blake, R.: Airborne particulate matter monitoring in Kenya using calibrated low-cost sensors, Atmos. Chem. Phys., 18, 15403–15418, https://doi.org/10.5194/acp-18-15403-2018, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Popoola, O. A. M., Stewart, G. B., Mead, M. I., and Jones, R. L.:
Development of a baseline-temperature correction methodology for
electrochemical sensors and its implications for long-term stability,
Atmos. Environ., 147, 330–343,
<a href="https://doi.org/10.1016/j.atmosenv.2016.10.024" target="_blank">https://doi.org/10.1016/j.atmosenv.2016.10.024</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Pringle, K. J., Tost, H., Pozzer, A., Pöschl, U., and Lelieveld, J.: Global distribution of the effective aerosol hygroscopicity parameter for CCN activation, Atmos. Chem. Phys., 10, 5241–5255, <a href="https://doi.org/10.5194/acp-10-5241-2010" target="_blank">https://doi.org/10.5194/acp-10-5241-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Sarangi, B., Aggarwal, S. G., Sinha, D., and Gupta, P. K.: Aerosol effective density measurement using scanning mobility particle sizer and quartz crystal microbalance with the estimation of involved uncertainty, Atmos. Meas. Tech., 9, 859–875, <a href="https://doi.org/10.5194/amt-9-859-2016" target="_blank">https://doi.org/10.5194/amt-9-859-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Shehab, M. A. and Pope, F. D.: Effects of short-term exposure to
particulate matter air pollution on cognitive performance, Sci. Rep., 9, 8237, <a href="https://doi.org/10.1038/s41598-019-44561-0" target="_blank">https://doi.org/10.1038/s41598-019-44561-0</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Shi, Z., Vu, T., Kotthaus, S., Harrison, R. M., Grimmond, S., Yue, S., Zhu, T., Lee, J., Han, Y., Demuzere, M., Dunmore, R. E., Ren, L., Liu, D., Wang, Y., Wild, O., Allan, J., Acton, W. J., Barlow, J., Barratt, B., Beddows, D., Bloss, W. J., Calzolai, G., Carruthers, D., Carslaw, D. C., Chan, Q., Chatzidiakou, L., Chen, Y., Crilley, L., Coe, H., Dai, T., Doherty, R., Duan, F., Fu, P., Ge, B., Ge, M., Guan, D., Hamilton, J. F., He, K., Heal, M., Heard, D., Hewitt, C. N., Hollaway, M., Hu, M., Ji, D., Jiang, X., Jones, R., Kalberer, M., Kelly, F. J., Kramer, L., Langford, B., Lin, C., Lewis, A. C., Li, J., Li, W., Liu, H., Liu, J., Loh, M., Lu, K., Lucarelli, F., Mann, G., McFiggans, G., Miller, M. R., Mills, G., Monk, P., Nemitz, E., O'Connor, F., Ouyang, B., Palmer, P. I., Percival, C., Popoola, O., Reeves, C., Rickard, A. R., Shao, L., Shi, G., Spracklen, D., Stevenson, D., Sun, Y., Sun, Z., Tao, S., Tong, S., Wang, Q., Wang, W., Wang, X., Wang, X., Wang, Z., Wei, L., Whalley, L., Wu, X., Wu, Z., Xie, P., Yang, F., Zhang, Q., Zhang, Y., Zhang, Y., and Zheng, M.: Introduction to the special issue “In-depth study of air pollution sources and processes within Beijing and its surrounding region (APHH-Beijing)”, Atmos. Chem. Phys., 19, 7519–7546, <a href="https://doi.org/10.5194/acp-19-7519-2019" target="_blank">https://doi.org/10.5194/acp-19-7519-2019</a>, 2019.

</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Smith, K. R., Edwards, P., Evans, M. J., Lee, J. D., Shaw, M. D., Squires,
F. A., and Lewis, A.: Clustering approaches to improve the performance of
low cost air pollution sensors, Faraday Discuss., 200, 1–15, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R.
W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., and Preuss,
P. W.: The Changing Paradigm of Air Pollution Monitoring, Environ. Sci. Technol., 47, 11369–11377, <a href="https://doi.org/10.1021/es4022602" target="_blank">https://doi.org/10.1021/es4022602</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Sousan, S., Koehler, K., Hallett, L., and Peters, T. M.: Evaluation of the
Alphasense optical particle counter (OPC-N2) and the Grimm portable aerosol
spectrometer (PAS-1.108), Aerosol. Sci. Tech., 50, 1352–1365,
2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Wexler, A. S. and Clegg, S. L.: Atmospheric aerosol models for systems
including the ions H<sup>+</sup>, NH<sub>4</sub><sup>+</sup>, Na<sup>+</sup>, SO<sub>4</sub><sup>2−</sup>, NO<sub>3</sub><sup>−</sup>, Cl<sup>−</sup>, Br<sup>−</sup>, and
H<sub>2</sub>O, 107, J. Geophys. Res.-Atmos., 107, ACH 14-11–ACH 14-14, <a href="https://doi.org/10.1029/2001JD000451" target="_blank">https://doi.org/10.1029/2001JD000451</a>, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Yin, J., Harrison, R. M., Chen, Q., Rutter, A., and Schauer, J. J.: Source
apportionment of fine particles at urban background and rural sites in the
UK atmosphere, Atmos. Environ., 44, 841–851,
<a href="https://doi.org/10.1016/j.atmosenv.2009.11.026" target="_blank">https://doi.org/10.1016/j.atmosenv.2009.11.026</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Xu, W., Sun, Y., Wang, Q., Zhao, J., Wang, J., Ge, X., Xie, C., Zhou, W.,
Du, W., Li, J., Fu, P., Wang, Z., Worsnop, D. R., and Coe, H.: Changes in
Aerosol Chemistry from 2014 to 2016 in Winter in Beijing: Insights from High
Resolution Aerosol Mass Spectrometry, J. Geophys. Res., 124, 1132–1147,
<a href="https://doi.org/10.1029/2018JD029245" target="_blank">https://doi.org/10.1029/2018JD029245</a>, 2019.