<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-13-3769-2020</article-id><title-group><article-title>Instrumental characteristics and potential greenhouse gas measurement capabilities of the Compact High-Spectral-Resolution Infrared Spectrometer: CHRIS</article-title><alt-title>Instrumental characteristics and potential capabilities of CHRIS</alt-title>
      </title-group><?xmltex \runningtitle{Instrumental characteristics and potential capabilities of CHRIS}?><?xmltex \runningauthor{M.-T.~El~Kattar et~al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="no">
          <name><surname>El Kattar</surname><given-names>Marie-Thérèse</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Auriol</surname><given-names>Frédérique</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="yes">
          <name><surname>Herbin</surname><given-names>Hervé</given-names></name>
          <email>herve.herbin@univ-lille.fr</email>
        </contrib>
        <aff id="aff1"><institution>Univ. Lille, CNRS, UMR 8518  –  LOA  –  Laboratoire d'Optique Atmosphérique, 59000 Lille, France</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Hervé Herbin (herve.herbin@univ-lille.fr)</corresp></author-notes><pub-date><day>13</day><month>July</month><year>2020</year></pub-date>
      
      <volume>13</volume>
      <issue>7</issue>
      <fpage>3769</fpage><lpage>3786</lpage>
      <history>
        <date date-type="received"><day>11</day><month>October</month><year>2019</year></date>
           <date date-type="accepted"><day>27</day><month>May</month><year>2020</year></date>
           <date date-type="rev-recd"><day>5</day><month>April</month><year>2020</year></date>
           <date date-type="rev-request"><day>5</day><month>November</month><year>2019</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2020 Marie-Thérèse El Kattar et al.</copyright-statement>
        <copyright-year>2020</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020.html">This article is available from https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e95">Ground-based high-spectral-resolution infrared measurements are an
efficient way to obtain accurate tropospheric abundances of different
gaseous species, in particular greenhouse gases (GHGs) such as
<inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Many ground-based spectrometers are used
in the NDACC and TCCON networks to validate the Level 2 satellite
data, but their large dimensions and heavy mass make them inadequate
for field campaigns. To overcome these problems, the use of portable
spectrometers was recently investigated. In this context, this paper
deals with the CHRIS (Compact High-Spectral-Resolution Infrared
Spectrometer) prototype with unique characteristics such as its high
spectral resolution (0.135 <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> nonapodized) and its wide
spectral range (680 to 5200 <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). Its main objective is
the characterization of gases and aerosols in the thermal and
shortwave infrared regions. That is why it requires high radiometric
precision and accuracy, which are achieved by performing spectral and
radiometric calibrations that are described in this paper. Furthermore,
CHRIS's capabilities to retrieve vertical <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
profiles are presented through a complete information content
analysis, a channel selection and an error budget estimation in the
attempt to join ongoing campaigns such as MAGIC (Monitoring of
Atmospheric composition and Greenhouse gases through multi-Instruments
Campaigns) to monitor GHGs and validate the actual and future
space missions such as IASI-NG and Microcarb.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e180">Remote-sensing techniques have gained a lot of popularity in the past
few decades due to the increasing need of continuous monitoring of
the atmosphere (<xref ref-type="bibr" rid="bib1.bibx15" id="altparen.1"/>). Greenhouse gases and trace gases as well as clouds and aerosols are detected and retrieved, thus improving
our understanding of the chemistry, physics and dynamics of the
atmosphere. Global-scale observations are achieved using satellites,
and one major technique is infrared high-spectral-resolution
spectroscopy (IRHSR). This technique offers radiometrically precise
observations at high spectral resolution (<xref ref-type="bibr" rid="bib1.bibx18" id="altparen.2"/>)
where quality measurements of absorption spectra are
obtained. TANSO-FTS (<xref ref-type="bibr" rid="bib1.bibx22" id="altparen.3"/>), IASI (<xref ref-type="bibr" rid="bib1.bibx3" id="altparen.4"/>)
and AIRS (<xref ref-type="bibr" rid="bib1.bibx1" id="altparen.5"/>) are examples of satellite sounders covering
the thermal infrared (TIR) region. The observations acquired from such
satellites have many advantages: day and night data
acquisition, possibility to measure concentrations of different gases,
the ability to cover land and sea surfaces (<xref ref-type="bibr" rid="bib1.bibx10" id="altparen.6"/>), and
the added characteristic of being highly sensitive to various types of
aerosol (<xref ref-type="bibr" rid="bib1.bibx2" id="altparen.7"/>). These spectrometers also have some
disadvantages: local observations are challenging to achieve due to
the pixel size that limits the spatial resolution, and the sensitivity
in the low atmospheric layers, where many short-lived gaseous
species are emitted but rarely detected, is weak.</p>
      <?pagebreak page3770?><p id="d1e205">To fill these gaps, ground-based instruments are used as
a complementary technique, and one famous high-precision Fourier-transform spectrometer is the IFS125HR from Bruker<sup>™</sup>,
which is briefly discussed in Sect. <xref ref-type="sec" rid="Ch1.S3.SS5"/> (further
details can be found in <xref ref-type="bibr" rid="bib1.bibx26" id="altparen.8"/>). More than 30 instruments
are currently deployed all over the world in two major international
networks: TCCON (<uri>https://tccondata.org/</uri>, last access: 22 June 2020) and NDACC (<uri>https://www.ndsc.ncep.noaa.gov/</uri>, last access: 22 June 2020). This particular instrument
has a very large size (<inline-formula><mml:math id="M7" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M8" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>) and a mass well
beyond 100 kg, therefore achieving a long optical
path difference and leading to a very high spectral resolution (0.02 and
<inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mn mathvariant="normal">5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for TCCON and NDACC,
respectively). Despite its outstanding capabilities, this spectrometer
is not suitable for field campaigns, so it is mainly used to validate
Level 2 satellite data, thus limiting the scientifically important
ground-based extension of atmospheric measurement around the world.</p>
      <p id="d1e287">One alternative is the new IFS125M from Bruker <xref ref-type="bibr" rid="bib1.bibx14" id="paren.9"/>,
which is the mobile version of the well-established IFS125HR
spectrometer. This spectrometer provides the highest resolution
available for a commercial mobile Fourier-transform infrared (FTIR) spectrometer, but it still has
a length of about 2 <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> and requires on-site realignment by
qualified personnel. Another alternative is the use of several compact
medium- to low-resolution instruments that are currently under
investigation, such as a grating spectrometer (0.16 <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>),
a fiber Fabry–Pérot interferometer (both setups presented in
<xref ref-type="bibr" rid="bib1.bibx11" id="altparen.10"/>) and the IFS66 from Bruker (0.11 <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)
described in <xref ref-type="bibr" rid="bib1.bibx16" id="text.11"/>. The EM27/SUN is the first instrument to
offer a compact, optically stable, transportable spectrometer <xref ref-type="bibr" rid="bib1.bibx8" id="paren.12"/> with a high signal-to-noise ratio (SNR) and that operates in the SWIR
(short-wavelength infrared) region. A new prototype called CHRIS
(Compact High-Spectral-Resolution Infrared Spectrometer) was conceived
to satisfy some very specific characteristics: high spectral
resolution (0.135 <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, better than TANSO-FTS and the
future IASI-NG) and a large spectral band (680–5200 <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) to
cover the current and future infrared satellite spectral range and
optimize the quantity of the measured species. Furthermore, this
prototype is transportable and can be operated for several hours by
battery (<inline-formula><mml:math id="M16" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:math></inline-formula> h), so it is suitable for field campaigns. The full
presentation of the characteristics and the calibration of this
instrumental prototype is presented in Sect. <xref ref-type="sec" rid="Ch1.S2"/>.</p>
      <p id="d1e379">Since carbon dioxide (<inline-formula><mml:math id="M17" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and methane (<inline-formula><mml:math id="M18" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) are the
two main greenhouse gases emitted by human activities, multiple
campaigns have been launched, such as the MAGIC (Monitoring of
Atmospheric composition and Greenhouse gases through multi-Instruments
Campaigns) initiative, to better understand the vertical exchange of
these greenhouse gases (GHGs) along the atmospheric column and to contribute to the
preparation and validation of future space missions dedicated to GHG
monitoring. CHRIS is part of this ongoing mission, and this work
presents for the first time the capabilities of such a setup in
achieving GHG measurements. Analysis of the forward model, state vector and
errors is explained in Sect. <xref ref-type="sec" rid="Ch1.S3"/>.</p>
      <p id="d1e407">In this context, we present in Sect. <xref ref-type="sec" rid="Ch1.S3.SS5"/> a complete
information content study for the retrieval of <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M20" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of two other ground-based instruments that also
participated in the MAGIC campaign: a comparison study with the
IFS125HR instrument and, since CHRIS and the EM27/SUN have a common band
in the SWIR region, a study to investigate the spectral synergy in
order to quantify the complementary aspects of the TIR–SWIR–NIR (NIR stands for near-infrared)
coupling for these two instruments. Moreover, Sect. <xref ref-type="sec" rid="Ch1.S4"/>
describes the channel selection made in this study. Finally, we
summarize our results and perspectives for future applications, in
particular the retrieval of GHGs in the MAGIC framework.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>The CHRIS spectrometer</title>
      <p id="d1e444">CHRIS is an instrumental prototype built by Bruker<sup>™</sup> and
used in different domains of atmospheric optics. Its recorded
spectra contain signatures of various atmospheric constituents such
as GHGs (<inline-formula><mml:math id="M21" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and trace gases. The
capacity to measure these species from a technical point of view as
well as the characterization of this prototype in terms of spectral
and radiometric calibrations is presented in the following
subsections.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e487">An internal look at CHRIS. The red arrows illustrate the optical path of the solar beam inside the spectrometer.</p></caption>
        <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f01.jpg"/>

      </fig>

<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>General characteristics</title>
      <p id="d1e503">CHRIS is a portable instrumental prototype with a mass of
approximately 40 <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi></mml:mrow></mml:math></inline-formula> and dimensions of <inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:mn mathvariant="normal">70</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">40</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">40</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula>, making it easy to operate in the field. The
tracker, which is similar to the one installed on the EM27/SUN and described in
detail in <xref ref-type="bibr" rid="bib1.bibx8" id="text.13"/>, leads the solar radiation through multiple
reflections on the mirrors to a wedged fused-silica window.</p>
      <p id="d1e549">An internal look at CHRIS is shown in Fig. <xref ref-type="fig" rid="Ch1.F1"/>, where the optical path of the solar beam is represented with red arrows: after multiple reflections
on the tracker's mirrors, the solar radiation enters the spectrometer
through the opening and is then reflected by the first mirror, where
the charge-coupled device (CCD) camera verifies the collimation of the beam on the second
mirror, which has a solar filter. At this level, CHRIS has a filter wheel
that can be equipped with up to five optical filters with a diameter of
25 <inline-formula><mml:math id="M27" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula>. Filters are widely used when making solar measurements
to reduce noise and nonlinearity effects. After reflection on the
second mirror, the beam enters the RockSolid<sup>™</sup> Michelson
interferometer, which has two cube-corner mirrors to ensure the optical
alignment stability of the beam and a KBr beam splitter. After that,
the radiation is blocked by an adjustable aperture stop, which can be
set to between 1 and 18 <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula>. This limits the parallel beam
parameter and can be used to reduce the intensity of the incoming
sunlight in case of saturation of the detector. The remaining
radiation falls onto an MCT (mercury cadmium telluride) detector; then it
is digitized to obtain the solar absorption spectra in arbitrary
units. This detector uses a closed-cycle Stirling cooling system
(a.k.a. cryocooler), so no liquid nitrogen has to be used. As the
vibrations of the compressor may introduce noise in the spectra (see
Sect. <xref ref-type="sec" rid="Ch1.S2.SS6"/>), a high scanning velocity (120 <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula>) is
needed.</p>
      <p id="d1e584"><?xmltex \hack{\newpage}?>A standard nonstabilized He–Ne las<?pagebreak page3771?>er controls the sampling of the
interferogram. The condensation of the warm, humid air on the beam splitter
due to its transportation between cold and warm environments is the main
reason a dessicant cartridge is used, so the spectrometer can
operate under various environmental conditions. CHRIS also has an internal
blackbody, which can be heated up to 353 <inline-formula><mml:math id="M30" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula> to make sure that there
is no drift in the TIR region, and it also serves as an optical source to
regularly verify the response of the detector.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Measurements and analysis</title>
      <p id="d1e605">CHRIS's method of data acquisition is explained as follows: the
interferograms are sampled and digitized by an analog-to-digital
converter (ADC) and then numerically resampled at constant intervals
of optical path difference (OPD) by a He–Ne reference laser signal
controlled by the aperture stop diameter. In order to determine
a suitable compromise between the latter and to avoid the saturation
of the signal, measurements must be done in a clear (no clouds or
aerosols) and nonpolluted (no gases with high chemical reactivity)
atmosphere. For this purpose, a field campaign was carried out at El Observatorio Atmosférico de Izaña (28.30<inline-formula><mml:math id="M31" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N,
16.48<inline-formula><mml:math id="M32" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> W) on the island of Tenerife. This particular observatory
site is high in altitude (2374 <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>), away from pollution sites
and has an IFS125HR listed in both the NDACC and TCCON
networks. Saturation of CHRIS's detector is reached at a value of
32 000 <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ADC</mml:mi></mml:mrow></mml:math></inline-formula>. The MCT detector is known for its high
photometric accuracy, but it also exhibits a nonlinear response with
regard to the energy flux in cases of high incident energy. This led
us to choose an aperture stop of 5 <inline-formula><mml:math id="M35" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula>, which is the best
compromise between saturation and incoming energy flux.</p>
      <p id="d1e650">Each spectrum corresponds to the solar transmission light in the total
atmospheric column in a field of view (FOV) of 0.006 <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mrad</mml:mi></mml:mrow></mml:math></inline-formula>. The
spectral range spans the region from 680 to 5200 cm<inline-formula><mml:math id="M37" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (1.9 to
14.7 <inline-formula><mml:math id="M38" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>), which corresponds to the middle-infrared region
(MIR). The water vapor causes the saturation we see between the bands,
thereby explaining the zero signal. Therefore, we divided the spectrum into four
distinctive spectral bands presented in Table <xref ref-type="table" rid="Ch1.T3"/>: TB (thermal
band; 680–1250 <inline-formula><mml:math id="M39" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>), B1 (1800–2300 <inline-formula><mml:math id="M40" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>), B2
(2400–3600 <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) and B3 (3900–5200 <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). This
annotation is used for the rest of the paper.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Optical features</title>
      <?pagebreak page3772?><p id="d1e750">A technical study was conducted on this prototype in order to evaluate
its optical and technical properties with a constant aperture stop
diameter of 5 <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula>. One of the most important findings is the
effect of the number of scans on the measured spectra. In practice,
a scan is the acquisition of a single interferogram when the mobile
mirror of the Michelson interferometer begins data collection at the
zero path difference (ZPD) and finishes at the maximum length,
therefore achieving the highest resolution required. In
Fig. <xref ref-type="fig" rid="Ch1.F2"/>, the spectrum with 10 scans has a higher amplitude
than those with 50 and 100 scans. On the other hand, the spectra with 50
and 100 scans are clearly less noisy than that with 10 scans. This
is due to the fact that the increase in the number of scans causes an
increase in the SNR, which leads to a decrease in noise. However,
there is a limit to the number of scans beyond which no improvement of
the SNR is obtained. The SNR is proportional to the square root of the
acquisition time (number of scans), also known as Fellgett's
advantage, and since the detector is dominated by shot noise, the
improvement of the SNR with the number of scans is blocked at
a certain value. This is why the spectra of 100 and 200 scans do
not show a significant difference. The SNR is an estimation of the
root-mean-squared noise of the covered spectral domain and can be
calculated in OPUS (the running program for CHRIS) using the function
SNR with the “fit parabola” option; it is estimated to be approximately
780. An optimized criterion is chosen to select the appropriate number
of scans: when the wanted species has a fast-changing concentration,
such as volcanic plumes, a relatively small number of scans is needed
to be able to follow the change in the atmospheric
composition temporally. In contrast, when measurements of relatively stable
atmospheric composition are made, for example GHGs (<inline-formula><mml:math id="M44" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M45" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), the number of scans can be increased to 100. For
instance, the time needed for one scan with a scanning velocity of
120 <inline-formula><mml:math id="M46" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula> is 0.83 <inline-formula><mml:math id="M47" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>, so 100 scans take approximately
83 <inline-formula><mml:math id="M48" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>, which is low in comparison to the variability of
<inline-formula><mml:math id="M49" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M50" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in the atmosphere.</p>
      <p id="d1e832">Another important feature is the effect of the gain amplitude (and
preamplifiers, which amplify the signal before digitization) on the spectra. Those parameters should be chosen in a way
that the numeric count falls in a region where no detector saturation
occurs. If the gain is increased by a certain amount, the background noise
is increased by the same amount. The use of such an option in the
measurement procedure might be considered in cases where the signal is
very weak, like lunar measurements. Note that there are other ways to
increase the intensity of the signal, like using signal amplifying filters
(see Sect. <xref ref-type="sec" rid="Ch1.S2.SS1"/>) or increasing the aperture stop diameter.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e839">Improvement of the SNR with different scan numbers and a fixed scan speed of 120 <inline-formula><mml:math id="M51" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f02.png"/>

        </fig>

<?xmltex \hack{\newpage}?>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><title>Radiometric and spectral calibration</title>
      <p id="d1e866">In the following section, the spectral and radiometric
calibrations are discussed in order to convert spectra from
numeric counts (expressed in arbitrary units) to radiance (<inline-formula><mml:math id="M52" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">W</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">sr</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula>).</p>
<sec id="Ch1.S2.SS4.SSS1">
  <label>2.4.1</label><title>Radiometric calibration</title>
      <p id="d1e905">Despite the fact that CHRIS has an internal blackbody, radiometric
calibration cannot be overlooked because of its narrow spectral
coverage (only the TIR region), and since the radiometric noise and the time- and wavelength-dependent calibration errors are magnified in
the inversion process, high radiometric precision is required to
derive atmospheric parameters from a spectrum. We calibrate our
spectra using the two-point calibration method explained in
<xref ref-type="bibr" rid="bib1.bibx18" id="text.14"/>. This method consists of using the observations
of hot and cold blackbody reference sources, which will be used as the
basis for the two-point calibration at each wave number. A cavity
blackbody was acquired by the LOA (Laboratoire d'Optique Atmosphérique) to perform regular radiometric
calibrations. The latter is an HGH/RCN1250N2, certified by the LNE
(Laboratoire National de métrologie et d'Essais) as having an
emissivity greater than 0.99 in the spectral domain spanned by CHRIS,
a stability of 0.1 at 1173 <inline-formula><mml:math id="M53" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula> and an opening diameter of up to
50 <inline-formula><mml:math id="M54" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> (corresponding to that of CHRIS) and as covering
temperatures from 323 to 1523 <inline-formula><mml:math id="M55" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula>. This cavity blackbody is
mounted on an optical bench and used before and after each campaign to
perform absolute radiometric calibrations through open-path
measurements and to make sure that this calibration is stable across the
whole spectral range. These two blackbody temperatures are viewed to
determine the slope <inline-formula><mml:math id="M56" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> and offset <inline-formula><mml:math id="M57" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula> (Eqs. <xref ref-type="disp-formula" rid="Ch1.E1"/> and <xref ref-type="disp-formula" rid="Ch1.E2"/>), which define the linear instrument response at each
wave number. The slope and the offset can be written following
<xref ref-type="bibr" rid="bib1.bibx18" id="text.15"/>:

                  <disp-formula specific-use="align" content-type="numbered"><mml:math id="M58" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E1"><mml:mtd><mml:mtext>1</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi>m</mml:mi></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">h</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mo>-</mml:mo><mml:msub><mml:mi>B</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">h</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E2"><mml:mtd><mml:mtext>2</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi>b</mml:mi></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>B</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">h</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mo>-</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">h</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>B</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">h</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mo>-</mml:mo><mml:msub><mml:mi>B</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

              where <inline-formula><mml:math id="M59" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> is the blackbody spectrum recorded, and <inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> corresponds to the calculated Planck blackbody radiance. The subscripts h and c correspond to the hot (1473 <inline-formula><mml:math id="M61" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula>) and cold (1273 <inline-formula><mml:math id="M62" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula>) blackbody temperatures, respectively. Finally, the calibrated spectrum expressed in watts per square meter steradian centimeter is obtained by applying the following formula:
              <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M63" display="block"><mml:mrow><mml:mi>L</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>S</mml:mi><mml:mo>-</mml:mo><mml:mi>b</mml:mi></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math id="M64" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> is the spectrum recorded by CHRIS.</p>
</sec>
<?pagebreak page3773?><sec id="Ch1.S2.SS4.SSS2">
  <label>2.4.2</label><title>Instrumental line shape and spectral calibration</title>
      <p id="d1e1191">One open-path measurement using the calibrated HGH blackbody as source
was performed, similar to the one previously described in
<xref ref-type="bibr" rid="bib1.bibx25" id="text.16"/>, to record a spectrum without applying any
apodization. Our colleagues in the PC2A laboratory provided us with
a 10 <inline-formula><mml:math id="M65" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula> long cell with a free diameter of 5 <inline-formula><mml:math id="M66" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula>, where
the pressure inside is monitored by a capacitive gauge. With the help
of the line-by-line radiative transfer algorithm ARAHMIS (atmospheric
radiation algorithm for high-spectral measurements from infrared
spectrometer) developed at the LOA laboratory, a maximum optical path difference (MOPD) of
4.42 <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula> was determined, corresponding to a spectral resolution
of 0.135 <inline-formula><mml:math id="M68" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> using a sinc function with a spectral
sampling every 0.06025 <inline-formula><mml:math id="M69" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> to satisfy the Nyquist
criterion. In FTIR spectroscopy, a poor instrumental line shape (ILS) determination generates
a significant error in the retrieval process, so we are currently
modifying the optical bench in order to perform an ILS determination
at the same time as the radiometric and spectral calibrations before
each field campaign.</p>
      <p id="d1e1250">The sampling of the interferogram is controlled by a standard, non-frequency-stabilized He–Ne laser with a wavelength of 632.8 <inline-formula><mml:math id="M70" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>,
which serves as a reference while converting from the distance scale
to the wave number scale. The instrument is subjected to changes in
pressure and temperature since it operates in different locations and
therefore under different meteorological conditions. This will cause
a change in the refractive index and as a consequence a change in the
reference wavelength of the laser, which will lead to an instability in
the conversion process and therefore the need for a spectral
calibration to reduce this error. The ILS line defined above is used
to resimulate isolated absorption lines from the high-resolution transmission molecular absorption (HITRAN) database
(<xref ref-type="bibr" rid="bib1.bibx9" id="altparen.17"/>) considering nonapodized spectra, which allows the
exploitation of the full spectral resolution. In short, we choose an
intense unsaturated <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> absorption line that is always present in the spectra; then we compare the central wave number (<inline-formula><mml:math id="M72" display="inline"><mml:mi mathvariant="italic">ν</mml:mi></mml:math></inline-formula>) with
the calculated one (<inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) following the equation

                  <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M74" display="block"><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msup><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>*</mml:mo></mml:msup><mml:mo>=</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>(</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mi mathvariant="italic">α</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

            where <inline-formula><mml:math id="M75" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is the calibration factor. Equation (<xref ref-type="disp-formula" rid="Ch1.E4"/>)
is limited by a precision of 0.038 <inline-formula><mml:math id="M76" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, corresponding to
roughly half of the spectral sampling, estimated from the standard
deviation between the theoretical HITRAN spectroscopic lines and the
measured ones by CHRIS. Figure <xref ref-type="fig" rid="Ch1.F3"/> shows the comparison
between a calibrated and a noncalibrated spectrum along with the
solar Planck function explained in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/>. The spectral
and radiometric calibration procedure is automated using a MATLAB
code to convert the spectra instantly from numeric counts to absolute
radiance.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e1354">The calibration process transforms the noncalibrated spectrum (light gray) into a calibrated one (black) that fits with the solar Planck function (solid gray line).</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f03.png"/>

          </fig>

<?xmltex \hack{\newpage}?>
</sec>
</sec>
<sec id="Ch1.S2.SS5">
  <label>2.5</label><title>Radiometric stability</title>
      <p id="d1e1374">During campaigns and after long transportation, constant measurement of the internal blackbody, which can be heated up to
353 <inline-formula><mml:math id="M77" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula>, is carried out in the thermal infrared region (most
affected by drifts). Figure <xref ref-type="fig" rid="Ch1.F4"/> shows the
variations of the internal blackbody during multiple field
campaigns: a little fluctuation in function of the measurement
conditions can be seen, but depending on the locations and even
years, no systematic drift can be detected, so we can safely say
that the instrument is quite stable between each laboratory
calibration.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e1389">The radiometric stability of the instrument is achieved by following the variations of the internal blackbody during multiple field campaigns. IZA:  Izana; MBR:  M'Bour; VDA:  Villeneuve d'Ascq; ASA:  Aire-sur-l'Adour.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f04.png"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS6">
  <label>2.6</label><title>Spectral artifacts</title>
      <p id="d1e1406">There are commonly several well-known spectral artifacts: aliasing, the picket fence effect (also known as the<?pagebreak page3774?> resolution
bias error) and phase correction. These are well controlled in
CHRIS.</p>
      <p id="d1e1409">Aliasing is the result of the missampling of the interferogram at the
<inline-formula><mml:math id="M78" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula>-axis locations, which leads to errors in the retrieved column
abundances due to its overlap with the original spectrum. The He–Ne laser,
having a wavelength <inline-formula><mml:math id="M79" display="inline"><mml:mi mathvariant="italic">λ</mml:mi></mml:math></inline-formula> of 632.8 <inline-formula><mml:math id="M80" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, generates the sampling
positions of the interferogram at each zero crossing. No overlap will
occur if the signal of the spectrum is zero above a maximum wave number
<inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and if <inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is smaller than the folding
wave number <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mi mathvariant="normal">f</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mo>(</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mo>⋅</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>x</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Since <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi mathvariant="italic">ν</mml:mi></mml:mrow></mml:math></inline-formula> is related to the
sample spacing <inline-formula><mml:math id="M85" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>x</mml:mi></mml:mrow></mml:math></inline-formula>, the minimum possible <inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>x</mml:mi></mml:mrow></mml:math></inline-formula> is
<inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">31</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mn mathvariant="normal">600</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M88" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula> since each zero crossing occurs every
<inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>. This corresponds to a folding wave number of
15 800 <inline-formula><mml:math id="M90" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, i.e., the maximum bandwidth that can be measured
without overlap has a width of 15 800 <inline-formula><mml:math id="M91" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. This source error
is of special relevance to the spectra acquired in the near-infrared
region. However, for the MIR, the investigated bandwidth is much smaller
than 15 800 <inline-formula><mml:math id="M92" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mtext>max</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is less than
5200 <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, so CHRIS's spectra are not affected by this problem
(<xref ref-type="bibr" rid="bib1.bibx6" id="altparen.18"/>).</p>
      <p id="d1e1623">The picket fence effect, or the resolution bias error, becomes evident
when the interferogram contains frequencies that do not coincide with
the frequency sample points, but this is overcome in our spectra by the
classical method of the zero filling factor (ZFF), where zeros are added to
the end of the interferogram before the Fourier transform is performed, thereby
doubling the size of the original interferogram.</p>
      <p id="d1e1626">Phase correction is necessary while converting the interferogram into
a spectrum, which is relevant to single-sided measurements, similar to
those acquired by CHRIS. Mertz phase correction is the method used for
CHRIS to overcome this problem; it relies on extracting the real part
of the spectrum from the complex output by multiplication of the latter by
the inverse of the phase exponential, therefore eliminating the complex
part of the spectrum generated.</p>
      <p id="d1e1630">Besides these classical FTIR artefacts, we noticed during our tests that
when using a scan speed of 160 <inline-formula><mml:math id="M95" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula>, we drastically increase the
nonlinearity effect of the detector (see
Fig. <xref ref-type="fig" rid="Ch1.F5"/>). However, we identified a ghost signal for low
scanning velocities (for example 40 <inline-formula><mml:math id="M96" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula> as shown in
Fig. <xref ref-type="fig" rid="Ch1.F6"/>). This ghost is specific to CHRIS because it is caused
by the noise introduced from the vibrations of the compressor used in the
closed-cycle Stirling cooler as mentioned in Sect. <xref ref-type="sec" rid="Ch1.S2.SS1"/>. The
choice of a scanning velocity of 120 <inline-formula><mml:math id="M97" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula> is a compromise between
two important features: the elimination of the ghost signal, which appears
at scanner velocities below 80 <inline-formula><mml:math id="M98" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula>, and the increase in the
detector nonlinearity at a velocity of 160 <inline-formula><mml:math id="M99" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e1682">Spectra of the external blackbody with two different scanning velocities: 120 <inline-formula><mml:math id="M100" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula> (black) and 160 <inline-formula><mml:math id="M101" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula> (light gray).</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f05.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><label>Figure 6</label><caption><p id="d1e1709">Spectra of the internal blackbody of CHRIS with scanner velocities of 40 <inline-formula><mml:math id="M102" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula> (black) and 120 <inline-formula><mml:math id="M103" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">KHz</mml:mi></mml:mrow></mml:math></inline-formula> (light gray).</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f06.png"/>

        </fig>

</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Information content analysis</title>
      <p id="d1e1743">Since CHRIS is an instrumental prototype, its ability to retrieve GHGs
is unknown; therefore it is important to perform an information
content study to quantify its potential
capability to retrieve GHGs as a first attempt. In this context, CHRIS is one of the
instruments deployed in the MAGIC project alongside satellites, lidar,
balloons and ground-based measurements. MAGIC is a French
initiative supported by the CNES (Centre National d'Etudes Spatiales),
which aims to implement and organize regular annual campaigns in order
to better understand the vertical exchange of GHGs (<inline-formula><mml:math id="M104" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M105" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) along the atmospheric column and establish a long-term
validation plan for the satellite Level 2 products.</p>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>The forward model</title>
      <?pagebreak page3775?><p id="d1e1775">Accurate calculations of the radiances observed by CHRIS are achieved
with the line-by-line radiative transfer algorithm ARAHMIS over the
thermal and shortwave infrared spectral range (1.9–14.7 µm). Gaseous
absorption is calculated based on the updated HITRAN 2016 database
(<xref ref-type="bibr" rid="bib1.bibx9" id="altparen.19"/>). The absorption lines are computed assuming a sinc
line shape, and no apodization is applied, which allows the exploitation
of the full spectral resolution. In this study, the term “all bands”
refers to the use of the CHRIS bands TB, B1, B2 and B3 simultaneously (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS2"/>). Absorption continua for
<inline-formula><mml:math id="M106" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M107" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are also included from the Mlawer–Tobin–Clough–Kneizys–Davies (MT-CKD) model
(<xref ref-type="bibr" rid="bib1.bibx4" id="altparen.20"/>). The pseudotransmittance spectra corresponding to
direct sunlight from the center of the solar disk reported by
<xref ref-type="bibr" rid="bib1.bibx23" id="text.21"/> is used as the incident solar spectrum interpolated on
the spectral grid of CHRIS. The effective brightness temperature
depends strongly on the wave number; thus the Planck function is
calculated in each spectral domain of CHRIS determined from
<xref ref-type="bibr" rid="bib1.bibx24" id="text.22"/>, who combined the work of four recent solar
reference spectra. Two of these reference spectra with 0.1 <inline-formula><mml:math id="M108" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>
relative difference are taken into consideration and then adjusted by
a polynomial fit (solid line in Fig. <xref ref-type="fig" rid="Ch1.F3"/>). In the gaseous
retrieval process, the spectrometer's line of sight (LOS) has to be
known for calculating the spectral absorption of the solar radiation
while passing through the atmosphere. For this, the time and the
duration of each measurement are saved, from which the required
effective solar elevation (and the solar zenith angle, SZA)
is calculated based on the routine explained in <xref ref-type="bibr" rid="bib1.bibx13" id="text.23"/>.</p>
      <p id="d1e1830">As mentioned in Sect. <xref ref-type="sec" rid="Ch1.S3.SS3.SSS2"/>, Izaña offers clear
nonpolluted measurements since it is high in altitude and away from major
pollution sites, so calculations are performed based on the concentration
of the desired atmospheric profile with the corresponding profile
information: the temperature, pressure and relative humidity are derived
from the radiosondes
(<uri>http://weather.uwyo.edu/upperair/sounding.html</uri>); <inline-formula><mml:math id="M109" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> profiles are derived from the TCCON database, whereas
<inline-formula><mml:math id="M111" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M113" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">CO</mml:mi></mml:mrow></mml:math></inline-formula> concentrations are calculated from
a typical midlatitude summer profile. Figure <xref ref-type="fig" rid="Ch1.F7"/> shows the
results of the forward model simulation superimposed with the four
infrared bands measured by CHRIS. For each band, we present the influence
of the solar spectrum, the GHGs (<inline-formula><mml:math id="M114" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M115" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and the major
interfering molecular absorbers. We can see good agreement between the
ARAHMIS simulations and the CHRIS measurements under clear sky conditions.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7" specific-use="star"><?xmltex \currentcnt{7}?><label>Figure 7</label><caption><p id="d1e1919">Measured and simulated CHRIS spectrum in transmittance for clear sky conditions at Izaña observatory. Each band is calculated from the line-by-line forward model ARAHMIS and the solar pseudotransmittance spectra reported by <xref ref-type="bibr" rid="bib1.bibx23" id="text.24"/>.</p></caption>
          <?xmltex \igopts{width=364.195276pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f07.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Information content theoretical basis</title>
      <p id="d1e1939">Once the forward model is calculated, we rely on the formalism of
<xref ref-type="bibr" rid="bib1.bibx19" id="text.25"/> that introduces the optimal estimation theory used for
the retrieval, which is widely described elsewhere
(e.g., <xref ref-type="bibr" rid="bib1.bibx10" id="altparen.26"/>) and summarized hereafter.</p>
      <p id="d1e1948">In the case of an atmosphere divided into discrete layers, the forward
radiative transfer equation gives an analytical relationship between
the set of observations <inline-formula><mml:math id="M116" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> (in this case the radiance) and the
vector of true atmospheric parameters <inline-formula><mml:math id="M117" display="inline"><mml:mi mathvariant="bold-italic">x</mml:mi></mml:math></inline-formula> (i.e., the variables to be retrieved: vertical concentration profiles of <inline-formula><mml:math id="M118" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and/or
<inline-formula><mml:math id="M119" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>):
            <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M120" display="block"><mml:mrow><mml:mi mathvariant="bold-italic">y</mml:mi><mml:mo>=</mml:mo><mml:mi>F</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="bold-italic">x</mml:mi><mml:mo>;</mml:mo><mml:mi mathvariant="bold-italic">b</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mi mathvariant="bold-italic">ε</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M121" display="inline"><mml:mi>F</mml:mi></mml:math></inline-formula> is the forward radiative transfer function (here the ARAHMIS code), <inline-formula><mml:math id="M122" display="inline"><mml:mi mathvariant="bold-italic">b</mml:mi></mml:math></inline-formula> represents the fixed parameters affecting the measurement (e.g., atmospheric temperature, interfering species, viewing angle), and <inline-formula><mml:math id="M123" display="inline"><mml:mi mathvariant="bold-italic">ε</mml:mi></mml:math></inline-formula> is the measurement error vector.</p>
      <p id="d1e2037">In the following information content study, two matrices fully
characterize the information provided by CHRIS: the averaging kernel
<inline-formula><mml:math id="M124" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> and the total error covariance <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e2058">The averaging kernel matrix <inline-formula><mml:math id="M126" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> gives a measurement of the sensitivity of the retrieved state to the true state and is defined by
            <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M127" display="block"><mml:mrow><mml:mi mathvariant="bold">A</mml:mi><mml:mo>=</mml:mo><mml:mo>∂</mml:mo><mml:mover accent="true"><mml:mi mathvariant="bold-italic">x</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover><mml:mo>/</mml:mo><mml:mo>∂</mml:mo><mml:mi mathvariant="bold-italic">x</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="bold">GK</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M128" display="inline"><mml:mi mathvariant="bold">K</mml:mi></mml:math></inline-formula> is the Jacobian matrix (also known as the weighting function). The <inline-formula><mml:math id="M129" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>th row contains the partial derivatives of the <inline-formula><mml:math id="M130" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>th measurement with respect to each (<inline-formula><mml:math id="M131" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula>) element of the state vector <inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">K</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:mo>∂</mml:mo><mml:msub><mml:mi mathvariant="bold-italic">F</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mo>∂</mml:mo><mml:msub><mml:mi mathvariant="bold-italic">x</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="bold">K</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula> is its transpose.</p>
      <p id="d1e2174">The gain matrix <inline-formula><mml:math id="M134" display="inline"><mml:mi mathvariant="bold">G</mml:mi></mml:math></inline-formula>, whose rows are the derivatives of the  retrieved state with respect to the spectral points, is defined by

                <disp-formula id="Ch1.E7" content-type="numbered"><label>7</label><mml:math id="M135" display="block"><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi mathvariant="bold">G</mml:mi><mml:mo>=</mml:mo><mml:mo>∂</mml:mo><mml:mover accent="true"><mml:mi mathvariant="bold-italic">x</mml:mi><mml:mo mathvariant="normal" stretchy="false">^</mml:mo></mml:mover><mml:mo>/</mml:mo><mml:mo>∂</mml:mo><mml:mi mathvariant="bold-italic">y</mml:mi><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:msup><mml:mi mathvariant="bold">K</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msup><mml:msubsup><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="italic">ε</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msubsup><mml:mi mathvariant="bold">K</mml:mi><mml:mo>+</mml:mo><mml:msubsup><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msubsup><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:msup><mml:mi mathvariant="bold">K</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msup><mml:msubsup><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="italic">ε</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msubsup><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the a priori covariance matrix describing our knowledge
of the state space prior to the measurement, and <inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="italic">ϵ</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>
represents the forward model and the measured signal error covariance
matrix.</p>
      <p id="d1e2290">At a given level, the peak of the averaging kernel row gives the
altitude of maximum sensitivity, whereas its full width at half
maximum (FWHM) is an estimate of the vertical resolution. The total
degrees of freedom for signal (DOFSs) is the trace of <inline-formula><mml:math id="M138" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula>, which
indicates the number of independent pieces of information that one can
extract from the observations with respect to the state
vector. A perfect retrieval resulting from an ideal inverse method
would lead to an averaging kernel matrix <inline-formula><mml:math id="M139" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> equal to the identity
matrix with a DOFS value equal to the size of the state vector. Therefore,
each parameter we want to retrieve is attached to the partial degree
of freedom represented by each diagonal element of <inline-formula><mml:math id="M140" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula>.</p>
      <?pagebreak page3777?><p id="d1e2314">The second important matrix in the information content (IC) study is the error covariance
matrix <inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, which describes our knowledge of the state space
posterior to the measurement. <xref ref-type="bibr" rid="bib1.bibx19" id="text.27"/> demonstrated that this
matrix can be written as

                <disp-formula id="Ch1.E8" content-type="numbered"><label>8</label><mml:math id="M142" display="block"><mml:mstyle displaystyle="true" class="stylechange"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>smoothing</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>meas.</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>fwd.mod.</mml:mtext></mml:msub></mml:mrow></mml:math></disp-formula>

          From Eq. (<xref ref-type="disp-formula" rid="Ch1.E8"/>), the smoothing error covariance matrix  <inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>smoothing</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> represents the vertical sensitivity of the measurements to the retrieved profile:

                <disp-formula id="Ch1.E9" content-type="numbered"><label>9</label><mml:math id="M144" display="block"><mml:mstyle displaystyle="true" class="stylechange"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>smoothing</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:mi mathvariant="bold">A</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="bold">I</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mo>(</mml:mo><mml:mi mathvariant="bold">A</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="bold">I</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mi mathvariant="normal">T</mml:mi></mml:msup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          <inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>meas.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> gives the contribution of the measurement
error covariance matrix through <inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, which
illustrates the measured signal error covariance matrix, to the
posterior error covariance matrix
<inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. <inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is computed from the
spectral noise:

                <disp-formula id="Ch1.E10" content-type="numbered"><label>10</label><mml:math id="M149" display="block"><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>meas.</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="bold">GS</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub><mml:msup><mml:mi mathvariant="bold">G</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          At last, <inline-formula><mml:math id="M150" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>fwd.mod.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> gives the contribution of the
posterior error covariance matrix through <inline-formula><mml:math id="M151" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">f</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, the forward model
error covariance matrix, which illustrates the imperfect knowledge of
the nonretrieved model parameters:

                <disp-formula id="Ch1.E11" content-type="numbered"><label>11</label><mml:math id="M152" display="block"><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>fwd.mod.</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="bold">GK</mml:mi><mml:mi>b</mml:mi></mml:msub><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>b</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="bold">GK</mml:mi><mml:mi>b</mml:mi></mml:msub><mml:msup><mml:mo>)</mml:mo><mml:mi mathvariant="normal">T</mml:mi></mml:msup><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="bold">GS</mml:mi><mml:mi mathvariant="normal">f</mml:mi></mml:msub><mml:msup><mml:mi mathvariant="bold">G</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msup><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          with <inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>b</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> representing the error covariance matrix of the
nonretrieved parameters.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>A priori information</title>
      <p id="d1e2591">The IC analysis uses simulated radiance spectra of CHRIS in the bands TB, B1, B2 and B3. The <inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M155" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> vertical concentrations of the a priori state vector <inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">x</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are based on a profile that follows the criteria described in
Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/> and discretized by 40 vertical layers, extending
from the ground to 40 <inline-formula><mml:math id="M157" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula> height with 1 <inline-formula><mml:math id="M158" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula> steps. In
addition, the vertical water vapor profile, the temperature and the
SZA are included in the nonretrieved parameters and are discussed in
Sect. <xref ref-type="sec" rid="Ch1.S3.SS3.SSS3"/>. The a priori values and their variabilities are
summarized in Table <xref ref-type="table" rid="Ch1.T1"/> and are described in the following
sections.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e2653">State vector parameters.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">State vector elements</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M159" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M160" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">SZA</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M161" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M162" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">A priori values</oasis:entry>
         <oasis:entry colname="col2">Radiosondes</oasis:entry>
         <oasis:entry colname="col3">Radiosondes</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">80</mml:mn></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M164" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">TCCON database</oasis:entry>
         <oasis:entry colname="col6">TCCON database</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">A priori uncertainty (<inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mtext>error</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">1 K per layer</oasis:entry>
         <oasis:entry colname="col3">10 <inline-formula><mml:math id="M166" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.35<inline-formula><mml:math id="M167" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">1.3 <inline-formula><mml:math id="M168" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>–8 <inline-formula><mml:math id="M169" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">5 <inline-formula><mml:math id="M170" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<sec id="Ch1.S3.SS3.SSS1">
  <label>3.3.1</label><title>A priori error covariance matrix</title>
      <p id="d1e2853">In situ data and climatology can give us an evaluation of the a priori
error covariance matrix <inline-formula><mml:math id="M171" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. Since the use of
diagonal a priori covariance matrices is common for retrievals
from space measurements (e.g., <xref ref-type="bibr" rid="bib1.bibx5" id="altparen.28"/>), and since this
study is dedicated to information coming from measurement rather
than climatology or in situ observations, we assume firstly that
<inline-formula><mml:math id="M172" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is a diagonal matrix with the <inline-formula><mml:math id="M173" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>th diagonal
element (<inline-formula><mml:math id="M174" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>) defined as

                  <disp-formula id="Ch1.E12" content-type="numbered"><label>12</label><mml:math id="M175" display="block"><mml:mstyle displaystyle="true" class="stylechange"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mtext>with</mml:mtext><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mspace width="0.25em" linebreak="nobreak"/><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>x</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>.</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mtext>error</mml:mtext></mml:msub></mml:mrow><mml:mn mathvariant="normal">100</mml:mn></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

            where <inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> stands for the standard deviation in the Gaussian statistics formalism. The subscript <inline-formula><mml:math id="M177" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> represents the <inline-formula><mml:math id="M178" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>th parameter
of the state vector. The <inline-formula><mml:math id="M179" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> profile a priori error is
estimated from <xref ref-type="bibr" rid="bib1.bibx20" id="text.29"/>. The <inline-formula><mml:math id="M180" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> a priori error is
fixed to <inline-formula><mml:math id="M181" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mtext>error</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M182" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>, similar to the one used in
<xref ref-type="bibr" rid="bib1.bibx17" id="text.30"/> for the retrieval of the methane obtained from IASI and
also to be consistent with the previous study concerning the TANSO-FTS
instrument (<xref ref-type="bibr" rid="bib1.bibx10" id="altparen.31"/>).</p>
      <p id="d1e3071">Nevertheless, the correlation of the vertical layers is more expressed by the off-diagonal matrix elements. This is the reason we also use an a priori covariance matrix similar to the one used in <xref ref-type="bibr" rid="bib1.bibx7" id="text.32"/>, where the climatology derived from TCCON is used to construct this matrix. The study with these two covariance matrices is presented for CHRIS in the following sections.</p>
</sec>
<sec id="Ch1.S3.SS3.SSS2">
  <label>3.3.2</label><title>Measurement error covariance matrix</title>
      <p id="d1e3086">The measurement error covariance matrix is computed knowing the instrument
performance and accuracy. The latter is related to the radiometric noise
expressed by the SNR already discussed in Sect. <xref ref-type="sec" rid="Ch1.S2.SS3"/>. This error
covariance matrix is assumed to be diagonal, and the <inline-formula><mml:math id="M183" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>th diagonal
element can be computed as follows:

                  <disp-formula id="Ch1.E13" content-type="numbered"><label>13</label><mml:math id="M184" display="block"><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mrow><mml:mi mathvariant="normal">m</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">m</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mspace linebreak="nobreak" width="1em"/><mml:mtext>with</mml:mtext><mml:mspace linebreak="nobreak" width="1em"/><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">m</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">y</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow><mml:mtext>SNR</mml:mtext></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

            where <inline-formula><mml:math id="M185" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">m</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the standard deviation of the <inline-formula><mml:math id="M186" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>th measurement (<inline-formula><mml:math id="M187" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">y</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) of the measurement vector <inline-formula><mml:math id="M188" display="inline"><mml:mi mathvariant="bold-italic">y</mml:mi></mml:math></inline-formula>, representing the noise-equivalent spectral radiance. The SNR for CHRIS is estimated to be 780, and it is reported with other instrumental characteristics in Table <xref ref-type="table" rid="Ch1.T3"/>.</p>
</sec>
<sec id="Ch1.S3.SS3.SSS3">
  <label>3.3.3</label><title>Nonretrieved parameter characterization and accuracy</title>
      <p id="d1e3212">The effects of nonretrieved parameters are a complicated part
of an error description model. In our case these uncertainties
are limited to the interfering water vapor molecules due to
their important existence in the spectra and the effect of the
temperature, where a vertically uniform uncertainty is assumed
in both cases. It is important to note that in this study
water vapor is considered as a nonretrieved parameter for
the sake of comparison with <xref ref-type="bibr" rid="bib1.bibx10" id="text.33"/>, but it will be
part of the retrieved state vector in the inversion process,
which will be the subject of a future study.</p>
      <p id="d1e3218">On the one hand, we assumed a partial column with an uncertainty
(<inline-formula><mml:math id="M189" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mtext>Cmol</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) of 10 <inline-formula><mml:math id="M190" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> instead of a profile error for
<inline-formula><mml:math id="M191" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>. On the other hand, we assumed a realistic uncertainty of
<inline-formula><mml:math id="M192" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mi>T</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> on each layer of the temperature
profile, which is compatible with the typical values used for
the European Centre for Medium-Range Weather Forecasts (ECMWF) assimilation. Moreover, we assumed a realistic uncertainty of 0.35<inline-formula><mml:math id="M193" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>
on the SZA, corresponding to the difference in the solar angle during
the acquisition of a measurement corresponding to 100 scans. All these
variabilities are reported in Table <xref ref-type="table" rid="Ch1.T1"/>.</p>
      <p id="d1e3283">The total forward model error covariance matrix
(<inline-formula><mml:math id="M194" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">f</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>), assumed to be diagonal in the present study, is
given by adding the contributions of each diagonal element, and the
<inline-formula><mml:math id="M195" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>th diagonal element (<inline-formula><mml:math id="M196" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mrow><mml:mi mathvariant="normal">f</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>) is given by

                  <disp-formula id="Ch1.E14" content-type="numbered"><label>14</label><mml:math id="M197" display="block"><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mrow><mml:mi mathvariant="normal">f</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>j</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mtext> level</mml:mtext></mml:mrow></mml:munderover><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">f</mml:mi><mml:mo>,</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">f</mml:mi><mml:mo>,</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:mi mathvariant="normal">f</mml:mi><mml:mo>,</mml:mo><mml:mtext>SZA</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

            Here, the spectroscopic effects such as the line parameter, the line
mixing and the continua errors are not considered, but they are
discussed with the <inline-formula><mml:math id="M198" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> column estimation in Sect. <xref ref-type="sec" rid="Ch1.S3.SS4.SSS2"/>.</p>
</sec>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Information content analysis applied to greenhouse gas profiles</title>
      <p id="d1e3446">An information content analysis is performed on the whole spectrum for
<inline-formula><mml:math id="M199" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M200" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> separately to quantify the benefit of the
multispectral synergy. Separately means that the state vector comprises only one of the above gas concentrations at each level
between 0 and 40 <inline-formula><mml:math id="M201" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula> to match the altitudes reached by TCCON
and the MAGIC instruments (balloons and planes reaching altitudes of
more than 25 <inline-formula><mml:math id="M202" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>). This corresponds to the case in which we
estimated each gas profile alone when all other atmospheric parameters
and all other gas profiles are known from ancillary data with
a specific variability or uncertainty. Two different SZAs (10 and
80<inline-formula><mml:math id="M203" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>)<?pagebreak page3778?> are chosen to demonstrate the effect of the solar
optical path on the study since the sensitivity is correlated to the
viewing geometry. Furthermore two different a priori covariance
matrices are used to show the effect of using climatological data
describing the variability of GHG profiles. In the following
subsections, we explain in detail the averaging kernel, error budget
and total column estimations.</p>
<sec id="Ch1.S3.SS4.SSS1">
  <label>3.4.1</label><title>Averaging kernel and error budget estimation</title>
      <p id="d1e3504">Figure <xref ref-type="fig" rid="Ch1.F8"/> shows the averaging kernel <inline-formula><mml:math id="M204" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> and total
posterior error <inline-formula><mml:math id="M205" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for an angle of
10<inline-formula><mml:math id="M207" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>. The figures of the second SZA (80<inline-formula><mml:math id="M208" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>) are not shown
since the vertical distribution of the kernels and errors is quite
similar and exhibits only slight differences in the amplitude with
respect to the other angle. However, the results are different; they are discussed in order to quantify the information
variability with the viewing geometry. <inline-formula><mml:math id="M209" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> is obtained for <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
independently using the variability introduced in
Sect. <xref ref-type="sec" rid="Ch1.S3.SS3.SSS1"/> and considering an observing system composed
of the band BT, B1, B2 or B3 separately and all the bands together to
quantify the contribution of each of the spectral bands and show the
benefits of the TIR–SWIR spectral synergy. Each colored line
represents the row of <inline-formula><mml:math id="M211" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> at each vertical grid layer. Each peak of
<inline-formula><mml:math id="M212" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> represents the partial degree of freedom of the gas at each level
that indicates the proportion of the information provided by the
measurement. In fact, if the value is close to unity, it means that
the information comes predominantly from the measurement, but a value
close to zero means that the information comes mainly from our prior
knowledge of the a priori state. We can clearly see that at lower
altitudes and up to 10 <inline-formula><mml:math id="M213" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>, the kernels are close to unity,
suggesting that the measurement improved our knowledge, while at
higher altitudes (beyond 10 <inline-formula><mml:math id="M214" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>) the kernels are close to
zero. It is also important to note that when using all the bands
simultaneously, the information distribution of the kernels is
improved and is more homogeneous along the vertical profile.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e3611">The total column errors for <inline-formula><mml:math id="M215" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M216" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> profiles for CHRIS for the two SZAs. The uncertainties are shown in percentages (%).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right" colsep="1"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Error</oasis:entry>
         <oasis:entry namest="col2" nameend="col3" align="center" colsep="1"><inline-formula><mml:math id="M217" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col4" nameend="col5" align="center"><inline-formula><mml:math id="M218" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">SZA</oasis:entry>
         <oasis:entry colname="col2">10<inline-formula><mml:math id="M219" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">80<inline-formula><mml:math id="M220" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">10<inline-formula><mml:math id="M221" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">80<inline-formula><mml:math id="M222" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Smoothing</oasis:entry>
         <oasis:entry colname="col2">2.79</oasis:entry>
         <oasis:entry colname="col3">2.51</oasis:entry>
         <oasis:entry colname="col4">4.34</oasis:entry>
         <oasis:entry colname="col5">4.11</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Measurement</oasis:entry>
         <oasis:entry colname="col2">0.6</oasis:entry>
         <oasis:entry colname="col3">0.54</oasis:entry>
         <oasis:entry colname="col4">0.59</oasis:entry>
         <oasis:entry colname="col5">0.7</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Nonretrieved parameters</oasis:entry>
         <oasis:entry colname="col2">0.14</oasis:entry>
         <oasis:entry colname="col3">0.12</oasis:entry>
         <oasis:entry colname="col4">0.27</oasis:entry>
         <oasis:entry colname="col5">0.5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Total</oasis:entry>
         <oasis:entry colname="col2">2.89</oasis:entry>
         <oasis:entry colname="col3">2.6</oasis:entry>
         <oasis:entry colname="col4">4.4</oasis:entry>
         <oasis:entry colname="col5">4.19</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><label>Figure 8</label><caption><p id="d1e3812">Averaging kernels and error budgets of vertical <inline-formula><mml:math id="M223" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> profiles for bands TB, B1 and B3 separately and all the bands together for an angle of 10<inline-formula><mml:math id="M224" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> for CHRIS. The red and solid black lines stand for the prior (<inline-formula><mml:math id="M225" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and posterior (<inline-formula><mml:math id="M226" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) errors, respectively; the smoothing (<inline-formula><mml:math id="M227" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>smoothing</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), measurement (<inline-formula><mml:math id="M228" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>meas.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and forward model parameter (<inline-formula><mml:math id="M229" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mtext>fwd.mod.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) errors are dash-dotted, dash-starred and dotted, respectively.</p></caption>
            <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f08.png"/>

          </fig>

      <p id="d1e3898">The measurement may provide information about <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> from the ground
up to 20 <inline-formula><mml:math id="M231" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula> high in the atmosphere (all bands), while at much
higher altitudes the information comes mainly from the a priori profile due to
a smaller sensitivity of these gases in the upper troposphere. This is
clearly represented in the error budget study: the a posteriori total
error (solid black line) is significantly smaller than the a priori error
(red line) in the lower part of the atmosphere (between 0 and
20 <inline-formula><mml:math id="M232" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>), which means that the measurement improved our knowledge of
the <inline-formula><mml:math id="M233" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> profile. Beyond 20 <inline-formula><mml:math id="M234" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>, the total
a posteriori error is equal to the a priori error, suggesting a very poor
sensitivity at high altitudes.  Furthermore, one can notice that the
measurement error stays very weak regardless of the band used, which proves
that the error related to the SNR is negligible. Furthermore, the forward model
error depending on the nonretrieved parameters remains quite
modest. However, the smoothing error predominates over the other errors and
becomes preponderant beyond 20 <inline-formula><mml:math id="M235" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>, which means that the
information is strongly constrained by the a priori profile at high
altitudes, and little information is introduced from the measurement. To
overcome this problem, another similar study was conducted but with
a nondiagonal a priori covariance matrix (<xref ref-type="bibr" rid="bib1.bibx7" id="altparen.34"/>). The vertical
distribution is more homogeneous through all the layers. The shape of the
error budget is very similar to that of the variance; however, the
a priori and a posteriori errors are significantly reduced. The
measurement and forward model errors remain weak, but it is important to
note that despite the fact that the smoothing error is smaller, the
constraint is stronger. This has the effect of decreasing the uncertainty but also increasing the propagation of the smoothing error along the vertical
layers, which explains the smaller values of the DOFSs.</p>
      <p id="d1e3959">Finally, the total DOFSs for <inline-formula><mml:math id="M236" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are shown in
Table <xref ref-type="table" rid="Ch1.T4"/> for angles of 10 and 80<inline-formula><mml:math id="M237" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. It shows
that for a diagonal a priori covariance matrix, one might be able to
retrieve between two and three partial tropospheric columns for
<inline-formula><mml:math id="M238" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and as expected the DOFS value is slightly higher at 80<inline-formula><mml:math id="M239" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>
since the optical path of the sun in every layer is longer. However, when
using a nondiagonal a priori covariance matrix, one less partial
tropospheric column is retrieved but with significant improvement in the
error budget estimation.</p>
      <?pagebreak page3779?><p id="d1e4005">The same reasoning is followed for <inline-formula><mml:math id="M240" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>: <inline-formula><mml:math id="M241" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> is obtained for
<inline-formula><mml:math id="M242" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> independently using the variability introduced in
Sect. <xref ref-type="sec" rid="Ch1.S3.SS3.SSS1"/> and considering an observing system composed of
the band TB, B1, B2 or B3 separately and all the bands
together. Figure <xref ref-type="fig" rid="Ch1.F9"/> shows that the vertical distribution of
<inline-formula><mml:math id="M243" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is more homogeneous than that of <inline-formula><mml:math id="M244" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and we can see
that the <inline-formula><mml:math id="M245" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula>'s are broader than those of <inline-formula><mml:math id="M246" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, suggesting a very
important correlation between layers. The use of all the bands
simultaneously, just like <inline-formula><mml:math id="M247" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, improves the information
distribution along the vertical profile. The forward model error is larger
than that of <inline-formula><mml:math id="M248" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> since methane is more affected by the
interfering species. The smoothing error is significantly larger than
<inline-formula><mml:math id="M249" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> since it is constrained by a much higher a priori profile variability, which
suggests a more direct effect on the retrieval of <inline-formula><mml:math id="M250" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. Similar
to <inline-formula><mml:math id="M251" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, when using a nondiagonal a priori covariance matrix, the
vertical distribution is very analogous to that of the variance
only. However, the a priori and a posteriori errors are significantly
reduced. The total DOFSs for <inline-formula><mml:math id="M252" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are shown in
Table <xref ref-type="table" rid="Ch1.T5"/> for both SZAs. This parameter shows that, for
a diagonal a priori covariance matrix, three partial tropospheric columns and one additional partial column for an SZA of
80<inline-formula><mml:math id="M253" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> can be retrieved. Finally, while using a nondiagonal a priori covariance
matrix the DOFSs show that one less partial column is retrieved.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9" specific-use="star"><?xmltex \currentcnt{9}?><label>Figure 9</label><caption><p id="d1e4162">Same as Fig. <xref ref-type="fig" rid="Ch1.F8"/> but for <inline-formula><mml:math id="M254" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with bands TB, B2 and B3 and all the bands together.</p></caption>
            <?xmltex \igopts{width=483.69685pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f09.png"/>

          </fig>

      <p id="d1e4184">As a general result, the simultaneous use of all the bands instead of
using each one separately increases the total DOFSs and systematically reduces the total errors of the two species. Moreover, using
a climatological a priori covariance matrix shows the importance of
reducing the error of the retrieved partial columns. Finally, the total
profile error is derived from the relative values of the diagonal matrix
of <inline-formula><mml:math id="M255" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (see Tables <xref ref-type="table" rid="Ch1.T4"/> and <xref ref-type="table" rid="Ch1.T5"/>),
which are discussed in detail in the following section.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e4206">Instrumental characteristics of CHRIS, the EM27/SUN and the IFS125HR of both NDACC and TCCON.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Resolution</oasis:entry>
         <oasis:entry colname="col3">MOPD</oasis:entry>
         <oasis:entry colname="col4">Spectral region</oasis:entry>
         <oasis:entry colname="col5">SNR</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">(cm<inline-formula><mml:math id="M256" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3">(cm)</oasis:entry>
         <oasis:entry colname="col4">(cm<inline-formula><mml:math id="M257" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">CHRIS</oasis:entry>
         <oasis:entry colname="col2">0.135</oasis:entry>
         <oasis:entry colname="col3">4.42</oasis:entry>
         <oasis:entry colname="col4">TB: 680–1250</oasis:entry>
         <oasis:entry colname="col5">780</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">B1: 1800–2300</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">B2: 2400–3600</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">B3: 3900–5200</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">EM27/SUN</oasis:entry>
         <oasis:entry colname="col2">0.5</oasis:entry>
         <oasis:entry colname="col3">1.8</oasis:entry>
         <oasis:entry colname="col4">B3: 4700–5200</oasis:entry>
         <oasis:entry colname="col5">1080</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">B4: 5460–7200</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">B5: 7370–12 500</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IFS125HR (TCCON)</oasis:entry>
         <oasis:entry colname="col2">0.02</oasis:entry>
         <oasis:entry colname="col3">45</oasis:entry>
         <oasis:entry colname="col4">4000–15 000</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M258" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">750</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IFS125HR (NDACC)</oasis:entry>
         <oasis:entry colname="col2">0.0035–0.007</oasis:entry>
         <oasis:entry colname="col3">128–257</oasis:entry>
         <oasis:entry colname="col4">5–5200</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M259" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1000</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S3.SS4.SSS2">
  <label>3.4.2</label><title>Total column estimation and uncertainty</title>
      <?pagebreak page3780?><p id="d1e4455">Ground-based instruments like the one used in the TCCON network and the
EM27/SUN operate in the NIR, where the column-averaged dry-air mole
fractions (denoted <inline-formula><mml:math id="M260" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for gas G) are calculated by monitoring the
observed <inline-formula><mml:math id="M261" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> columns. <inline-formula><mml:math id="M262" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is calculated by rationing the gas-retrieved slant column to the <inline-formula><mml:math id="M263" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>-retrieved slant column for the
same spectrum. Especially among the NDACC
community, another method is used to calculate <inline-formula><mml:math id="M264" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> without using the oxygen reference. Based on
the formula given in <xref ref-type="bibr" rid="bib1.bibx26" id="text.35"/> and used in <xref ref-type="bibr" rid="bib1.bibx27" id="text.36"/>, we can
calculate <inline-formula><mml:math id="M265" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M266" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M267" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>:

                  <disp-formula id="Ch1.E15" content-type="numbered"><label>15</label><mml:math id="M268" display="block"><mml:mstyle displaystyle="true" class="stylechange"/><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mtext>column</mml:mtext><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow><mml:mtext>column dry air</mml:mtext></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula>

              <disp-formula id="Ch1.Ex1"><mml:math id="M269" display="block"><mml:mrow><mml:mtext>column dry air</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>air</mml:mtext></mml:msub><mml:msubsup><mml:mi>m</mml:mi><mml:mtext>air</mml:mtext><mml:mtext>dry</mml:mtext></mml:msubsup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>-</mml:mo><mml:msub><mml:mtext>column</mml:mtext><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msubsup><mml:mi>m</mml:mi><mml:mtext>air</mml:mtext><mml:mtext>dry</mml:mtext></mml:msubsup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math id="M270" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M271" display="inline"><mml:mrow><mml:msubsup><mml:mi>m</mml:mi><mml:mtext>air</mml:mtext><mml:mtext>dry</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula> are the mean molecular
masses of water and dry air, respectively; <inline-formula><mml:math id="M272" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the surface pressure; and
<inline-formula><mml:math id="M273" display="inline"><mml:mrow><mml:msub><mml:mi>g</mml:mi><mml:mtext>air</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the column-averaged gravitational
acceleration. Therefore, the calculation of <inline-formula><mml:math id="M274" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is possible if all these
parameters are available, particularly within the MAGIC framework, where we
have access to the balloons and
radiosondes data (temperature, surface pressure, relative humidity
etc.) along with all the instruments involved. Thus, for these particular
campaigns, <inline-formula><mml:math id="M275" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values will be calculated for CHRIS using ARAHMIS, and
the results will be compared with the other instruments involved,
especially the IFS125HR of the TCCON network and the EM27/SUN. This
will be the subject of an upcoming paper. However, the two equations for
the calculation of <inline-formula><mml:math id="M276" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi mathvariant="normal">G</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are not strictly similar since the EM27/SUN
eliminates the systematic errors that are common to the target gas and
<inline-formula><mml:math id="M277" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column retrievals, which will not be possible for us since the
<inline-formula><mml:math id="M278" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> band is not detected by CHRIS.</p>
      <p id="d1e4755">In addition, the total column uncertainty is calculated by adding the
concentration of each layer along the profile, weighted by the column
of dry air based on Figs. <xref ref-type="fig" rid="Ch1.F8"/> and
<xref ref-type="fig" rid="Ch1.F9"/>. Table <xref ref-type="table" rid="Ch1.T2"/> lists the propagated uncertainties
of the total column<?pagebreak page3781?> for both SZAs using a diagonal a priori covariance
matrix: the uncertainty of the total <inline-formula><mml:math id="M279" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column is 2.89 <inline-formula><mml:math id="M280" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>
and 2.6 <inline-formula><mml:math id="M281" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for 10 and 80<inline-formula><mml:math id="M282" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, respectively, while
the uncertainty for the total <inline-formula><mml:math id="M283" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column is 4.4 <inline-formula><mml:math id="M284" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> and
4.19 <inline-formula><mml:math id="M285" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for 10 and 80<inline-formula><mml:math id="M286" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, respectively. The
uncertainties are smaller for an SZA of 80<inline-formula><mml:math id="M287" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> because the
information distribution is improved with a longer OPD. Furthermore,
these results show that the total profile error for <inline-formula><mml:math id="M288" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is
almost 2 times higher than that of <inline-formula><mml:math id="M289" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, but this is explained
by the fact that our profile error is limited by the a priori profile
error, which is much higher for <inline-formula><mml:math id="M290" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> than for <inline-formula><mml:math id="M291" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. The
dominating component of the uncertainty comes from the smoothing, which
predominates over the other uncertainties for both GHGs and is the major
contributor to the total profile error. <inline-formula><mml:math id="M292" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, temperature and
SZA are the most important parameters contributing to the forward
model; they are represented by the nonretrieved parameter
uncertainty. Additionally, it is important to note that there is
a supplementary uncertainty associated with the spectroscopy unaccounted
for in our study, which is purely systematic. It is not simple to
evaluate in this case because we use different spectral domains, each
having different spectroscopic uncertainties listed in the HITRAN
database.</p>
</sec>
</sec>
<sec id="Ch1.S3.SS5">
  <label>3.5</label><title>Comparison and complementary information content analysis for the IFS125HR, the EM27/SUN and CHRIS</title>
      <p id="d1e4915">During the MAGIC campaigns, several EM27/SUN and two IFS125HR instruments from the TCCON network were operated alongside CHRIS. An information content analysis is presented in the following sections for both of these instruments in order to compare and complement the study performed on CHRIS in Sect. <xref ref-type="sec" rid="Ch1.S3.SS4"/>.</p>
<sec id="Ch1.S3.SS5.SSS1">
  <label>3.5.1</label><title>Complementary information with the EM27/SUN</title>
      <p id="d1e4927">In this section, an IC study is performed for the EM27/SUN instrument
in order to compare it with our results and to investigate the
possibility of complementing the data we obtained from CHRIS,
especially for MAGIC. The bands of the EM27/SUN used in this study are
denoted as follows: B3 is the common band with CHRIS and has a spectral
range of 4700–5200 <inline-formula><mml:math id="M293" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, B4 goes from 5460 to
7200 <inline-formula><mml:math id="M294" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, and B5 spans the spectral region between 7370
and 12 500 <inline-formula><mml:math id="M295" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e4972">Firstly, a similar study to CHRIS is performed on the EM27/SUN for
<inline-formula><mml:math id="M296" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M297" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> separately. As mentioned in
Sect. <xref ref-type="sec" rid="Ch1.S3.SS4"/>, the state vector comprises only one of
the gas concentrations with the same profile at a layer going from 0
to 40 <inline-formula><mml:math id="M298" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>; however, we took into account the SNR and spectral
resolution specific to this instrument (see
Table <xref ref-type="table" rid="Ch1.T3"/>). Similar to the reasoning for CHRIS followed in
Sect. <xref ref-type="sec" rid="Ch1.S3.SS4"/>, this study shows that using all the EM27/SUN
bands together leads to an improvement of the a posteriori error
profile of <inline-formula><mml:math id="M299" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations, especially in the lower part of
the atmosphere. Table <xref ref-type="table" rid="Ch1.T4"/> shows the DOFSs for <inline-formula><mml:math id="M300" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
of the EM27/SUN: using a diagonal a priori covariance matrix for an angle
of 10<inline-formula><mml:math id="M301" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>, the total DOFSs for bands B3 (common band with CHRIS) and
B4 as well as all bands together are 2.95, 1.63 and 3.03, respectively. If
only band B3 is taken into consideration, which is the common band
between the two instruments, the DOFSs of CHRIS in this band are, as
stated before, 2.62 and 3.34 for an angle of 10 and 80<inline-formula><mml:math id="M302" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>,
respectively, compared to 2.95 and 3.17 for the EM27/SUN. Therefore, the
same number of partial columns can be retrieved using CHRIS (see
Sect. <xref ref-type="sec" rid="Ch1.S3.SS4"/>) for <inline-formula><mml:math id="M303" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in this band. Furthermore,
similar to CHRIS, the total error is reduced with a more
propagated smoothing error on the profile and a reduction in the
DOFSs when using a nondiagonal a priori covariance
matrix (<xref ref-type="bibr" rid="bib1.bibx7" id="altparen.37"/>). As for <inline-formula><mml:math id="M304" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and referring to Table <xref ref-type="table" rid="Ch1.T3"/>, band 3
in this instrument begins (4700 <inline-formula><mml:math id="M305" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) where the <inline-formula><mml:math id="M306" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
band ends (4150–4700 <inline-formula><mml:math id="M307" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) in the IFS125HR and CHRIS. This is
important because TCCON networks begin their measurements at
4000 <inline-formula><mml:math id="M308" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, which allowed for the comparison with band 3 of
CHRIS (for both <inline-formula><mml:math id="M309" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M310" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). However, the EM27/SUN
instruments have no exploitable signal before 4700 <inline-formula><mml:math id="M311" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>
(<xref ref-type="bibr" rid="bib1.bibx8" id="altparen.38"/>); therefore the <inline-formula><mml:math id="M312" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption lines do not
show in the common band between CHRIS and the EM27/SUN, so the results
are not discussed here.</p>
      <p id="d1e5190">Secondly, a simultaneous IC study was performed on all the channels
of both CHRIS and the EM27/SUN in order to analyze the complementary
aspect of these two instruments. The results of this study are shown
in Fig. <xref ref-type="fig" rid="Ch1.F10"/>. The DOFSs obtained for <inline-formula><mml:math id="M313" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are
3.67 and 3.93 for angles 10 and 80<inline-formula><mml:math id="M314" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, respectively; for <inline-formula><mml:math id="M315" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> they are 3.99 and 4.43. This indicates a significant
improvement of the retrieval when the spectral synergy between TIR, SWIR and NIR
is used, but it is less than the one obtained from space (for example
TANSO-FTS in <xref ref-type="bibr" rid="bib1.bibx10" id="altparen.39"/>) since the measurement is obtained
from the same optical path.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10" specific-use="star"><?xmltex \currentcnt{10}?><label>Figure 10</label><caption><p id="d1e5233">Averaging kernels and error budgets of vertical <inline-formula><mml:math id="M316" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M317" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> profiles for all the bands together for the EM27/SUN and CHRIS combined for an angle of 10<inline-formula><mml:math id="M318" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>. The red and black lines stand for the prior (<inline-formula><mml:math id="M319" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and posterior (<inline-formula><mml:math id="M320" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) errors, respectively; the smoothing (<inline-formula><mml:math id="M321" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>smoothing</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), measurement (<inline-formula><mml:math id="M322" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>meas.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and forward model parameter (<inline-formula><mml:math id="M323" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>fwd.mod.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) errors are dash-dotted, dash-starred and dotted, respectively.</p></caption>
            <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f10.png"/>

          </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e5332">The DOFSs and column errors (%) of <inline-formula><mml:math id="M324" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for each band and for each instrument.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="right" colsep="1"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">TB</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">B1</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">B3</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">B4</oasis:entry>
         <oasis:entry rowsep="1" namest="col7" nameend="col8" align="center">All bands </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry namest="col3" nameend="col6" colsep="1">DOFSs </oasis:entry>
         <oasis:entry colname="col7">DOFSs</oasis:entry>
         <oasis:entry colname="col8">Error</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">CHRIS</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">2.01</oasis:entry>
         <oasis:entry colname="col4">2.32</oasis:entry>
         <oasis:entry colname="col5">2.62</oasis:entry>
         <oasis:entry colname="col6">–</oasis:entry>
         <oasis:entry colname="col7">2.95</oasis:entry>
         <oasis:entry colname="col8">2.89 <inline-formula><mml:math id="M325" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2">Angle 80</oasis:entry>
         <oasis:entry rowsep="1" colname="col3">2.56</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">2.67</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">3.34</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">–</oasis:entry>
         <oasis:entry rowsep="1" colname="col7">3.71</oasis:entry>
         <oasis:entry rowsep="1" colname="col8">2.6 <inline-formula><mml:math id="M326" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CHRIS with covariance</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">1.45</oasis:entry>
         <oasis:entry colname="col4">1.7</oasis:entry>
         <oasis:entry colname="col5">2.15</oasis:entry>
         <oasis:entry colname="col6">–</oasis:entry>
         <oasis:entry colname="col7">2.38</oasis:entry>
         <oasis:entry colname="col8">1.01 <inline-formula><mml:math id="M327" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Angle 80</oasis:entry>
         <oasis:entry colname="col3">1.89</oasis:entry>
         <oasis:entry colname="col4">1.92</oasis:entry>
         <oasis:entry colname="col5">2.68</oasis:entry>
         <oasis:entry colname="col6">–</oasis:entry>
         <oasis:entry colname="col7">3.08</oasis:entry>
         <oasis:entry colname="col8">0.94 <inline-formula><mml:math id="M328" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">EM27/SUN</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
         <oasis:entry colname="col5">2.95</oasis:entry>
         <oasis:entry colname="col6">1.63</oasis:entry>
         <oasis:entry colname="col7">3.03</oasis:entry>
         <oasis:entry colname="col8">2.77 <inline-formula><mml:math id="M329" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2">Angle 80</oasis:entry>
         <oasis:entry rowsep="1" colname="col3">–</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">–</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">3.17</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">2.33</oasis:entry>
         <oasis:entry rowsep="1" colname="col7">3.31</oasis:entry>
         <oasis:entry rowsep="1" colname="col8">2.67 <inline-formula><mml:math id="M330" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">EM27/SUN with covariance</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
         <oasis:entry colname="col5">2.25</oasis:entry>
         <oasis:entry colname="col6">1.17</oasis:entry>
         <oasis:entry colname="col7">2.37</oasis:entry>
         <oasis:entry colname="col8">1.01 <inline-formula><mml:math id="M331" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Angle 80</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
         <oasis:entry colname="col5">2.53</oasis:entry>
         <oasis:entry colname="col6">1.71</oasis:entry>
         <oasis:entry colname="col7">2.68</oasis:entry>
         <oasis:entry colname="col8">0.97 <inline-formula><mml:math id="M332" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IFS125HR</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">2.15</oasis:entry>
         <oasis:entry colname="col4">2.33</oasis:entry>
         <oasis:entry colname="col5">3.07</oasis:entry>
         <oasis:entry colname="col6">2.62</oasis:entry>
         <oasis:entry colname="col7">3.9</oasis:entry>
         <oasis:entry colname="col8">2.82 <inline-formula><mml:math id="M333" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2">Angle 80</oasis:entry>
         <oasis:entry rowsep="1" colname="col3">2.51</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">2.61</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">3.59</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">2.99</oasis:entry>
         <oasis:entry rowsep="1" colname="col7">4.23</oasis:entry>
         <oasis:entry rowsep="1" colname="col8">2.72 <inline-formula><mml:math id="M334" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IFS125HR with covariance</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">1.66</oasis:entry>
         <oasis:entry colname="col4">1.85</oasis:entry>
         <oasis:entry colname="col5">2.86</oasis:entry>
         <oasis:entry colname="col6">2.3</oasis:entry>
         <oasis:entry colname="col7">3.28</oasis:entry>
         <oasis:entry colname="col8">0.97 <inline-formula><mml:math id="M335" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Angle 80</oasis:entry>
         <oasis:entry colname="col3">1.97</oasis:entry>
         <oasis:entry colname="col4">2.14</oasis:entry>
         <oasis:entry colname="col5">3.04</oasis:entry>
         <oasis:entry colname="col6">2.61</oasis:entry>
         <oasis:entry colname="col7">3.53</oasis:entry>
         <oasis:entry colname="col8">0.95 <inline-formula><mml:math id="M336" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T5" specific-use="star"><?xmltex \currentcnt{5}?><label>Table 5</label><caption><p id="d1e5832">The DOFSs and column errors (%) of <inline-formula><mml:math id="M337" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for each band and for each instrument.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="center" colsep="1"/>
     <oasis:colspec colnum="7" colname="col7" align="center"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry rowsep="1" colname="col3">TB</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">B2</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">B3</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">B4</oasis:entry>
         <oasis:entry rowsep="1" namest="col7" nameend="col8">All bands </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry namest="col3" nameend="col6" colsep="1">DOFSs </oasis:entry>
         <oasis:entry colname="col7">DOFSs</oasis:entry>
         <oasis:entry colname="col8">Error</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">CHRIS</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">2.77</oasis:entry>
         <oasis:entry colname="col4">2.87</oasis:entry>
         <oasis:entry colname="col5">2.62</oasis:entry>
         <oasis:entry colname="col6">–</oasis:entry>
         <oasis:entry colname="col7">3.34</oasis:entry>
         <oasis:entry colname="col8">4.4 <inline-formula><mml:math id="M338" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2">Angle 80</oasis:entry>
         <oasis:entry rowsep="1" colname="col3">3.19</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">3.88</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">3.45</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">–</oasis:entry>
         <oasis:entry rowsep="1" colname="col7">4.26</oasis:entry>
         <oasis:entry rowsep="1" colname="col8">4.19 <inline-formula><mml:math id="M339" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CHRIS with covariance</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">2.03</oasis:entry>
         <oasis:entry colname="col4">2.22</oasis:entry>
         <oasis:entry colname="col5">1.97</oasis:entry>
         <oasis:entry colname="col6">–</oasis:entry>
         <oasis:entry colname="col7">2.57</oasis:entry>
         <oasis:entry colname="col8">1.5 <inline-formula><mml:math id="M340" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Angle 80</oasis:entry>
         <oasis:entry colname="col3">2.23</oasis:entry>
         <oasis:entry colname="col4">2.83</oasis:entry>
         <oasis:entry colname="col5">2.56</oasis:entry>
         <oasis:entry colname="col6">–</oasis:entry>
         <oasis:entry colname="col7">3.21</oasis:entry>
         <oasis:entry colname="col8">1.46 <inline-formula><mml:math id="M341" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">EM27/SUN</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
         <oasis:entry colname="col5">–</oasis:entry>
         <oasis:entry colname="col6">1.69</oasis:entry>
         <oasis:entry colname="col7">1.69</oasis:entry>
         <oasis:entry colname="col8">4.67 <inline-formula><mml:math id="M342" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2">Angle 80</oasis:entry>
         <oasis:entry rowsep="1" colname="col3">–</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">–</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">–</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">2.45</oasis:entry>
         <oasis:entry rowsep="1" colname="col7">2.45</oasis:entry>
         <oasis:entry rowsep="1" colname="col8">4.54 <inline-formula><mml:math id="M343" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">EM27/SUN with covariance</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
         <oasis:entry colname="col5">–</oasis:entry>
         <oasis:entry colname="col6">1.18</oasis:entry>
         <oasis:entry colname="col7">1.18</oasis:entry>
         <oasis:entry colname="col8">1.59 <inline-formula><mml:math id="M344" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Angle 80</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
         <oasis:entry colname="col5">–</oasis:entry>
         <oasis:entry colname="col6">1.81</oasis:entry>
         <oasis:entry colname="col7">1.81</oasis:entry>
         <oasis:entry colname="col8">1.55 <inline-formula><mml:math id="M345" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IFS125HR</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">3.37</oasis:entry>
         <oasis:entry colname="col4">3.97</oasis:entry>
         <oasis:entry colname="col5">3.69</oasis:entry>
         <oasis:entry colname="col6">2.56</oasis:entry>
         <oasis:entry colname="col7">4.64</oasis:entry>
         <oasis:entry colname="col8">4.23 <inline-formula><mml:math id="M346" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2">Angle 80</oasis:entry>
         <oasis:entry rowsep="1" colname="col3">3.66</oasis:entry>
         <oasis:entry rowsep="1" colname="col4">4.42</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">4.23</oasis:entry>
         <oasis:entry rowsep="1" colname="col6">3.35</oasis:entry>
         <oasis:entry rowsep="1" colname="col7">4.98</oasis:entry>
         <oasis:entry rowsep="1" colname="col8">4.21 <inline-formula><mml:math id="M347" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IFS125HR with covariance</oasis:entry>
         <oasis:entry colname="col2">Angle 10</oasis:entry>
         <oasis:entry colname="col3">2.45</oasis:entry>
         <oasis:entry colname="col4">3.03</oasis:entry>
         <oasis:entry colname="col5">2.79</oasis:entry>
         <oasis:entry colname="col6">1.83</oasis:entry>
         <oasis:entry colname="col7">3.55</oasis:entry>
         <oasis:entry colname="col8">1.47 <inline-formula><mml:math id="M348" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Angle 80</oasis:entry>
         <oasis:entry colname="col3">2.57</oasis:entry>
         <oasis:entry colname="col4">3.34</oasis:entry>
         <oasis:entry colname="col5">3.22</oasis:entry>
         <oasis:entry colname="col6">2.45</oasis:entry>
         <oasis:entry colname="col7">3.81</oasis:entry>
         <oasis:entry colname="col8">1.46 <inline-formula><mml:math id="M349" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S3.SS5.SSS2">
  <label>3.5.2</label><title>Comparison with the IFS125HR</title>
      <p id="d1e6337">As mentioned before, the IFS125HR is a ground-based high-resolution
infrared spectrometer used at NDACC and TCCON stations around
the world. We performed a similar information content study only
on the TCCON instrument since this network is involved in the
MAGIC campaigns; therefore the results can be compared. For
simplicity, the same annotation of the bands is kept for this
section. The same methodology described in Sect. <xref ref-type="sec" rid="Ch1.S3.SS4"/>
is used here: the state vector comprises only <inline-formula><mml:math id="M350" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math id="M351" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations at a layer going from 0 to
40 <inline-formula><mml:math id="M352" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>, where the SNR and the spectral resolution specific
to the IFS125HR are taken into consideration (see
Table <xref ref-type="table" rid="Ch1.T3"/>).</p>
      <p id="d1e6374">We follow the same reasoning as in the sections before:
Fig. <xref ref-type="fig" rid="Ch1.F11"/> shows the averaging kernel <inline-formula><mml:math id="M353" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> and
the total posterior error <inline-formula><mml:math id="M354" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M355" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M356" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for an angle of 10<inline-formula><mml:math id="M357" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>. We can see that the
vertical distribution is more homogeneous than CHRIS and the EM27/SUN,
suggesting a high sensitivity at high altitudes, although in the
lower atmosphere the a posteriori error <inline-formula><mml:math id="M358" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is
significantly reduced. This is also shown in<?pagebreak page3782?> the error budget
study: we can still distinguish the a posteriori total error
(solid black line) from the a priori error (red line) even in the
higher atmosphere. This is explained by the fact that the IFS125HR
has a spectral resolution higher than both CHRIS and the EM27/SUN, so
the measurement always improves our knowledge of the profile all
along the atmospheric column. Furthermore, when using a nondiagonal
a priori covariance matrix, the total profile error is
significantly reduced, especially for <inline-formula><mml:math id="M359" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>; however, the
DOFSs are also reduced.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11" specific-use="star"><?xmltex \currentcnt{11}?><label>Figure 11</label><caption><p id="d1e6453">Averaging kernels and error budgets of <inline-formula><mml:math id="M360" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M361" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and vertical profiles for all the bands together for an angle of 10<inline-formula><mml:math id="M362" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> for the IFS125HR. The red and black lines stand for the prior (<inline-formula><mml:math id="M363" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and posterior (<inline-formula><mml:math id="M364" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>x</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) errors, respectively; the smoothing (<inline-formula><mml:math id="M365" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>smoothing</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>), measurement (<inline-formula><mml:math id="M366" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>meas.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) and forward model parameter (<inline-formula><mml:math id="M367" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mtext>fwd.mod.</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) errors are dash-dotted, dash-starred and dotted, respectively.</p></caption>
            <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f11.png"/>

          </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T6"><?xmltex \currentcnt{6}?><label>Table 6</label><caption><p id="d1e6553">Corresponding number of selected channels for the DOFSs of <inline-formula><mml:math id="M368" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M369" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and their respective percentage of the total number of channels for CHRIS.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left" colsep="1"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">DOFSs</oasis:entry>
         <oasis:entry namest="col2" nameend="col3" align="center" colsep="1"><inline-formula><mml:math id="M370" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col4" nameend="col5" align="center"><inline-formula><mml:math id="M371" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">90 <inline-formula><mml:math id="M372" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">99 <inline-formula><mml:math id="M373" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">90 <inline-formula><mml:math id="M374" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">99 <inline-formula><mml:math id="M375" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Number of channels</oasis:entry>
         <oasis:entry colname="col2">1329</oasis:entry>
         <oasis:entry colname="col3">4648</oasis:entry>
         <oasis:entry colname="col4">1387</oasis:entry>
         <oasis:entry colname="col5">5924</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Percentage of the</oasis:entry>
         <oasis:entry colname="col2">2.15 <inline-formula><mml:math id="M376" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">7.54 <inline-formula><mml:math id="M377" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">2.25 <inline-formula><mml:math id="M378" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">9.61 <inline-formula><mml:math id="M379" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">total number</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">of channels</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e6767">The DOFSs of <inline-formula><mml:math id="M380" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M381" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are shown in
Table <xref ref-type="table" rid="Ch1.T4"/> for both viewing angles and a priori covariance
matrices. On the one hand, one additional partial tropospheric column for
<inline-formula><mml:math id="M382" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> can be retrieved with respect to CHRIS for an angle of
10<inline-formula><mml:math id="M383" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> and with respect to the EM27/SUN for both angles if all the bands are used. On
the other hand, one additional partial tropospheric column can be
retrieved for <inline-formula><mml:math id="M384" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with respect to CHRIS for both angles if all the bands are used.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12"><?xmltex \currentcnt{12}?><label>Figure 12</label><caption><p id="d1e6828">Evolution of the DOFSs with the number of selected channels for <inline-formula><mml:math id="M385" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (black) and <inline-formula><mml:math id="M386" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (gray).</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/13/3769/2020/amt-13-3769-2020-f12.png"/>

          </fig>

</sec>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Channel selection</title>
      <p id="d1e6869">Using all the channels in the retrieval process has two
disadvantages. First of all, it requires a very large computational
time. Secondly, the correlation of the interfering species increases
the systematic error. In this case, the a priori state vector
<inline-formula><mml:math id="M387" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">x</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and the error covariance matrix
<inline-formula><mml:math id="M388" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are very difficult to evaluate. Channel
selection is a method described by <xref ref-type="bibr" rid="bib1.bibx19" id="text.40"/> to optimize
a retrieval by objectively selecting the subset of channels that
provides the greatest amount of information from high-resolution
infrared sounders. <xref ref-type="bibr" rid="bib1.bibx12" id="text.41"/> offer a description of this
procedure based on the Shannon information content. Firstly, we create
an “information spectrum” in order to evaluate the information
content with respect to the a priori state vector. The channel with
the largest amount of information is then selected. A new spectrum is
then calculated with a new a posteriori covariance matrix that is
adjusted according to the channel selected in the first iteration to
account for the information it provides. In this way a second channel
is chosen, based on this newly defined state space. This channel provides
maximal information relative to the new a posteriori covariance
matrix. This process is repeated, and channels are selected
sequentially until the information in all the remaining channels falls
below the level of measurement noise. As stated by the Shannon information
content and noted in <xref ref-type="bibr" rid="bib1.bibx19" id="text.42"/>, it is convenient to work on
a basis on which the measurement errors and prior variances are
uncorrelated in order to compare the measurement error with the
natural variability of the measurements across the full prior
state. Therefore, it is desirable to transform the Jacobian matrix <inline-formula><mml:math id="M389" display="inline"><mml:mi mathvariant="bold">K</mml:mi></mml:math></inline-formula>
(see Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>) into <inline-formula><mml:math id="M390" display="inline"><mml:mover accent="true"><mml:mi mathvariant="bold">K</mml:mi><mml:mo stretchy="false" mathvariant="normal">̃</mml:mo></mml:mover></mml:math></inline-formula> using

              <disp-formula id="Ch1.E16" content-type="numbered"><label>16</label><mml:math id="M391" display="block"><mml:mstyle class="stylechange" displaystyle="true"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mover accent="true"><mml:mi mathvariant="bold">K</mml:mi><mml:mo mathvariant="normal" stretchy="false">̃</mml:mo></mml:mover><mml:mo>=</mml:mo><mml:msubsup><mml:mi mathvariant="bold">S</mml:mi><mml:mi>y</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msubsup><mml:msubsup><mml:mi mathvariant="bold">KS</mml:mi><mml:mi mathvariant="normal">a</mml:mi><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msubsup><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

       <?pagebreak page3784?> which offers the added benefit of being the basis on which both the
a priori and the measurement covariance matrices are unit
matrices. Furthermore, Rodgers demonstrates that the number of
singular values of <inline-formula><mml:math id="M392" display="inline"><mml:mover accent="true"><mml:mi mathvariant="bold">K</mml:mi><mml:mo stretchy="false" mathvariant="normal">̃</mml:mo></mml:mover></mml:math></inline-formula> greater than unity defines the
number of independent measurements that exceed the measurement noise
defining the effective rank of the problem.</p>
      <p id="d1e6976">Letting <inline-formula><mml:math id="M393" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> be the error covariance matrix for the state space after <inline-formula><mml:math id="M394" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> channels have been selected, the information content of channel <inline-formula><mml:math id="M395" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula> of the remaining unselected channels is given by

              <disp-formula id="Ch1.E17" content-type="numbered"><label>17</label><mml:math id="M396" display="block"><mml:mstyle displaystyle="true" class="stylechange"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>H</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">2</mml:mn></mml:mfrac></mml:mstyle><mml:msub><mml:mi>log⁡</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mfenced open="(" close=")"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:msubsup><mml:mover accent="true"><mml:mi mathvariant="bold-italic">k</mml:mi><mml:mo stretchy="false" mathvariant="normal">̃</mml:mo></mml:mover><mml:mi>j</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msubsup><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:msub><mml:mover accent="true"><mml:mi mathvariant="bold-italic">k</mml:mi><mml:mo stretchy="false" mathvariant="normal">̃</mml:mo></mml:mover><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        where <inline-formula><mml:math id="M397" display="inline"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi mathvariant="bold-italic">k</mml:mi><mml:mo mathvariant="normal" stretchy="false">̃</mml:mo></mml:mover><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the <inline-formula><mml:math id="M398" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula>th row of <inline-formula><mml:math id="M399" display="inline"><mml:mover accent="true"><mml:mi mathvariant="bold">K</mml:mi><mml:mo stretchy="false" mathvariant="normal">̃</mml:mo></mml:mover></mml:math></inline-formula>. <inline-formula><mml:math id="M400" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>
constitutes the information spectrum from which the first channel is
selected. Taking the chosen channel to be channel <inline-formula><mml:math id="M401" display="inline"><mml:mi>l</mml:mi></mml:math></inline-formula>, the covariance
matrix is then updated before the next iteration using the following
statement:

              <disp-formula id="Ch1.E18" content-type="numbered"><label>18</label><mml:math id="M402" display="block"><mml:mstyle displaystyle="true" class="stylechange"/><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msubsup><mml:mi mathvariant="bold">S</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msubsup><mml:mo>=</mml:mo><mml:msubsup><mml:mi mathvariant="bold">S</mml:mi><mml:mi>i</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msubsup><mml:mo>+</mml:mo><mml:msub><mml:mover accent="true"><mml:mi mathvariant="bold-italic">k</mml:mi><mml:mo mathvariant="normal" stretchy="false">̃</mml:mo></mml:mover><mml:mi>l</mml:mi></mml:msub><mml:msubsup><mml:mover accent="true"><mml:mi mathvariant="bold-italic">k</mml:mi><mml:mo stretchy="false" mathvariant="normal">̃</mml:mo></mml:mover><mml:mi>l</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msubsup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

        In this way, channels are selected until 90 <inline-formula><mml:math id="M403" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the total
information spectrum <inline-formula><mml:math id="M404" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> is reached in a way that the measurement noise
is not exceeded.</p>
      <p id="d1e7184">After that, <inline-formula><mml:math id="M405" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>, expressed in bits, is converted to DOFSs to obtain Fig. <xref ref-type="fig" rid="Ch1.F12"/>, which represents the total DOFS evolution for <inline-formula><mml:math id="M406" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M407" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> as a function of the number of selected channels for all spectral bands and for an SZA of 10<inline-formula><mml:math id="M408" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>. CHRIS has 75 424 channels in total; 13 800 are unusable because of the water vapor saturation between the bands, which leaves us with 61 624 exploitable
channels. A preselection of these channels, based on
Fig. <xref ref-type="fig" rid="Ch1.F7"/>, is done where the number of exploitable channels is
reduced to the spectral areas where we find <inline-formula><mml:math id="M409" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M410" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (13 447 and 19 751 preselected channels,
respectively). In Fig. <xref ref-type="fig" rid="Ch1.F12"/>, the DOFSs for each
gas increase sharply with the first selected channels at first glance and then more
steadily. The number of channels required to reach 90 <inline-formula><mml:math id="M411" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> and
99 <inline-formula><mml:math id="M412" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the total information is represented in
Table <xref ref-type="table" rid="Ch1.T6"/>. For <inline-formula><mml:math id="M413" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, out of the 1329 channels,
55.76 <inline-formula><mml:math id="M414" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the information comes from B3 (common band with
the EM27/SUN), 37.24 <inline-formula><mml:math id="M415" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> from TB and 6.99 <inline-formula><mml:math id="M416" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> from B1. As for <inline-formula><mml:math id="M417" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, out of the 1387 channels, 46.86 <inline-formula><mml:math id="M418" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the information comes from B2, 28.19 <inline-formula><mml:math id="M419" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> from TB and 24.9 <inline-formula><mml:math id="M420" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> from B3. This result shows that most of the information for <inline-formula><mml:math id="M421" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M422" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> comes from B3 and TB,
respectively, which indicates that the synergy between TIR and SWIR
observations is confirmed.</p>
      <p id="d1e7366">Furthermore, the 1329 and 1387 selected channels represent
2.15 <inline-formula><mml:math id="M423" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> and 2.25 <inline-formula><mml:math id="M424" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the 61 624 exploitable
channels, respectively, so a retrieval process that uses selected
channels corresponding to 90 <inline-formula><mml:math id="M425" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the total information
content would give comparable results to the one using the entire set
of channels since almost 98 <inline-formula><mml:math id="M426" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the information is
redundant. Hence, these results indicate the interest of determining
an optimal set of channels for each gas separately. This is why this
channel selection will be used in the retrieval process, making it
easier and less time consuming.</p>
</sec>
<sec id="Ch1.S5" sec-type="conclusions">
  <label>5</label><title>Conclusions</title>
      <?pagebreak page3785?><p id="d1e7410">In conclusion, this paper presents the characteristics of the new
infrared spectrometer CHRIS, which allows the retrieval of GHGs and trace
gases. This instrumental prototype has unique characteristics such as
its high spectral resolution (0.135 <inline-formula><mml:math id="M427" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) and wide spectral
range (680–5200 <inline-formula><mml:math id="M428" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>), covering the MIR region. In the
context of its exploitation to retrieve GHGs, spectral and radiometric
calibrations were performed using a calibrated external blackbody
reaching a temperature of 1523 <inline-formula><mml:math id="M429" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula>. Additionally, between
laboratory calibrations and during field campaigns the radiometric
stability is monitored through measurements of the internal
blackbody. Within the MAGIC framework, an extensive information content
analysis is performed, showing the potential capabilities of this
instrument to retrieve GHGs using two different SZAs (10 and
80<inline-formula><mml:math id="M430" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) to quantify the improvement of the information
with the solar optical path. Furthermore, two a priori covariance
matrices were used: one diagonal and another derived from
climatological data. The total column uncertainty is estimated, showing
that when using a diagonal a priori covariance matrix the error for an
angle of 10<inline-formula><mml:math id="M431" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> is of the order of 2.89 <inline-formula><mml:math id="M432" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for
<inline-formula><mml:math id="M433" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and 4.4 <inline-formula><mml:math id="M434" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M435" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for all the bands;
however, when using a climatological distribution the total column
error for the same angle and for all the bands is reduced to
1.01 <inline-formula><mml:math id="M436" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M437" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and 1.5 <inline-formula><mml:math id="M438" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for <inline-formula><mml:math id="M439" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> but
with a significant decrease in the DOFSs (from 2.95 to 2.38 for
<inline-formula><mml:math id="M440" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and from 3.34 to 2.57 for <inline-formula><mml:math id="M441" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). Furthermore, a comparison
study with the IFS125HR of the TCCON, which is widely used in the
satellite validation process, is performed, illustrating the benefits
of its high spectral resolution for GHG retrievals. Moreover,
a complementary study is carried out on the EM27/SUN to investigate
the possibility of a retrieval exploiting the synergy between
TIR, SWIR and NIR observations, which showed that a significant improvement
can be obtained. For example, with an SZA of 10<inline-formula><mml:math id="M442" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> the DOFSs are
increased from 2.95 to 3.67. Finally, a channel selection is
implemented to remove the redundant information. The latter will be
used in future work dedicated to the <inline-formula><mml:math id="M443" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M444" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
total column retrievals for the MAGIC campaigns.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e7604">All CHRIS data are available by contacting the authors.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e7610">MTEK and HH wrote the paper and produced the main analysis and results. FA, HH and MTEK designed the calibration study, performed the laboratory measurements and participated in the field campaigns. All authors read and provided comments on the paper.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e7616">The authors declare that they have no conflict of interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e7622">We acknowledge Fabrice Ducos for providing IT support and extensive expertise that greatly assisted this work and most of all for his great work on the ARAHMIS algorithm development. We would also like to thank the Ecole Centrale de Lille for its help on the radiometric calibration. Finally, we acknowledge Denis Petitprez from the PC2A laboratory for his experimental help on the ILS characterization.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e7627">This research has been supported by the CNES (Centre National d'Etudes Spatiales) TOSCA-MAGIC project.The CaPPA (Chemical and Physical Properties of the Atmosphere) project is funded by the French National Research Agency (ANR) through the PIA (Programme d'Investissement d'Avenir) (contract no. ANR-11-LABX-0005-01) and by the regional council Nord Pas de Calais-Picardie and the European Funds for Regional Economic Development (FEDER).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e7633">This paper was edited by Alyn Lambert and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Aumann et al.(2003)</label><?label airs?><mixed-citation>Aumann, H. H., Chahine, M. T., Gautier, C., Goldberg, M. D., Kalnay, E.,
McMillin L. M., Revercomb, H., Rosenkranz, P. W., Smith, W. L.,
Staelin, D. H., Strow, L. L., and Susskind, J.: AIRS/AMSU/HSB on the Aqua mission: design, science objectives, data products, and processing systems, IEEE T. Geosci. Remote, 41, 253–264, <ext-link xlink:href="https://doi.org/10.1109/TGRS.2002.808356" ext-link-type="DOI">10.1109/TGRS.2002.808356</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Clarisse et al.(2010)</label><?label Clarisse:10?><mixed-citation>Clarisse, L., Hurtmans, D., Prata, A. J., Karagulian, F., Clerbaux, C., Mazière, M. D., and Coheur, P.-F.: Retrieving radius, concentration, optical depth, and mass of different types of aerosols from high-resolution infrared nadir spectra, Appl. Optics, 49, 3713–3722, <ext-link xlink:href="https://doi.org/10.1364/AO.49.003713" ext-link-type="DOI">10.1364/AO.49.003713</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Clerbaux et al.(2007)</label><?label iasi-gen?><mixed-citation>Clerbaux, C., Hadji-Lazaro, J., Turquety, S., George, M., Coheur, P.-F., Hurtmans, D., Wespes, C., Herbin, H., Blumstein, D., Tourniers, B., and Phulpin, T.: The IASI/MetOp1 Mission: First observations and highlights of its potential contribution to GMES2, Space Res. Today, 168, 19–24, <ext-link xlink:href="https://doi.org/10.1016/S0045-8732(07)80046-5" ext-link-type="DOI">10.1016/S0045-8732(07)80046-5</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Clough et al.(2005)</label><?label clough?><mixed-citation>Clough, S. A., Shephard, M. W., Mlawer, E. J., Delamere, J. S., Iacono, M. J.,
Cady-Pereira, K., Boukabara, S., and Brown, P. D.: Atmospheric radiative
transfer modeling: a summary of the AER codes, J. Quant. Spectrosc. Ra., 91, 233–244, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2004.05.058" ext-link-type="DOI">10.1016/j.jqsrt.2004.05.058</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>De Wachter et al.(2017)</label><?label dewachter?><mixed-citation>De Wachter, E., Kumps, N., Vandaele, A. C., Langerock, B., and De Mazière, M.: Retrieval and validation of MetOp/IASI methane, Atmos. Meas. Tech., 10, 4623–4638, <ext-link xlink:href="https://doi.org/10.5194/amt-10-4623-2017" ext-link-type="DOI">10.5194/amt-10-4623-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Dohe et al.(2013)</label><?label dohe?><mixed-citation>Dohe, S., Sherlock, V., Hase, F., Gisi, M., Robinson, J., Sepúlveda, E., Schneider, M., and Blumenstock, T.: A method to correct sampling ghosts in historic near-infrared Fourier transform spectrometer (FTS) measurements, Atmos. Meas. Tech., 6, 1981–1992, <ext-link xlink:href="https://doi.org/10.5194/amt-6-1981-2013" ext-link-type="DOI">10.5194/amt-6-1981-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Eguchi et al.(2010)</label><?label eguchi?><mixed-citation>Eguchi, N., Saito, R., Saeki, T., Nakatsuka, Y., Belikov, D., and
Maksyutov, S.:  A priori covariance estimation for <inline-formula><mml:math id="M445" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M446" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> retrievals, J. Geophys. Res., 115, D10215,
<ext-link xlink:href="https://doi.org/10.1029/2009JD013269" ext-link-type="DOI">10.1029/2009JD013269</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Gisi et al.(2012)</label><?label Gisi?><mixed-citation>Gisi, M., Hase, F., Dohe, S., Blumenstock, T., Simon, A., and Keens, A.: XCO<inline-formula><mml:math id="M447" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>-measurements with a tabletop FTS using solar absorption spectroscopy, Atmos. Meas. Tech., 5, 2969–2980, <ext-link xlink:href="https://doi.org/10.5194/amt-5-2969-2012" ext-link-type="DOI">10.5194/amt-5-2969-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Gordon et al.(2017)</label><?label hitran?><mixed-citation>Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K., Drouin, B. J., Flaud, J.-M., Gamache, R. R., Hodges, J. T., Jacquemart, D., Perevalov, V. I., Perrin, A., Shine, K. P., Smith, M.-A. H., Tennyson, J., Toon, G. C., Tran, H., Tyuterev, V. G., Barbe, A., Császár, A. G., Devi, V. M., Furtenbacher, T., Harrison, J. J., Hartmann, J.-M., Jolly, A., Johnson, T. J., Karman, T., Kleiner, I., Kyuberis, A. A., Loos, J., Lyulin, O. M., Massie, S. T., Mikhailenko, S. N., Moazzen-Ahmadi, N., Muller, H. S. P., Naumenko, O. V., Nikitin, A. V., Polyansky, O. L., Rey, M., Rotger, M., Sharpe, S. W., Sung, K., Starikova, E., Tashkun, S. A., Auwera, J. V., Wagner, G., Wilzewski, J., Wcislo, P., Yu, S., and Zak, E. J.: The HITRAN2016 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 203, 3–69, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2017.06.038" ext-link-type="DOI">10.1016/j.jqsrt.2017.06.038</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Herbin et al.(2013a)</label><?label tanso1?><mixed-citation>Herbin, H., Labonnote, L. C., and Dubuisson, P.: Multispectral information
from TANSO-FTS instrument – Part 1: Application to greenhouse gases (CO<inline-formula><mml:math id="M448" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and CH<inline-formula><mml:math id="M449" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula>) in clear sky conditions, Atmos. Meas. Tech., 6, 3301–3311, <ext-link xlink:href="https://doi.org/10.5194/amt-6-3301-2013" ext-link-type="DOI">10.5194/amt-6-3301-2013</ext-link>, 2013.</mixed-citation></ref>
      <?pagebreak page3786?><ref id="bib1.bibx11"><label>Kobayashi et al.(2010)</label><?label kobayashi?><mixed-citation>Kobayashi, N., Inoue, G., Kawasaki, M., Yoshioka, H., Minomura, M., Murata, I., Nagahama, T., Matsumi, Y., Tanaka, T., Morino, I., and Ibuki, T.: Remotely operable compact instruments for measuring atmospheric CO<inline-formula><mml:math id="M450" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and CH<inline-formula><mml:math id="M451" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula> column densities at surface monitoring sites, Atmos. Meas. Tech., 3, 1103–1112, <ext-link xlink:href="https://doi.org/10.5194/amt-3-1103-2010" ext-link-type="DOI">10.5194/amt-3-1103-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>L'Ecuyer et al.(2006)</label><?label l'ecuyer?><mixed-citation>L'Ecuyer, T. S., Gabriel, P., Leesman, K., Cooper, S. J., and Stephens, G. L.: Objective Assessment of the Information Content of Visible and Infrared Radiance Measurements for Cloud Microphysical Property Retrievals over the Global Oceans. Part I: Liquid Clouds, J. Appl. Meteorol. Clim., 45, 20–41, <ext-link xlink:href="https://doi.org/10.1175/JAM2326.1" ext-link-type="DOI">10.1175/JAM2326.1</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Michalsky(1988)</label><?label Michalsky1988?><mixed-citation>Michalsky, J. J.: The Astronomical Almanac's algorithm for approximate solar position (1950–2050), J. Sol. Energ., 40, 227–235, <ext-link xlink:href="https://doi.org/10.1016/0038-092X(88)90045-X" ext-link-type="DOI">10.1016/0038-092X(88)90045-X</ext-link>, 1988.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Pathatoki et al.(2019)</label><?label mahesh?><mixed-citation>Pathakoti, M., Gaddamidi, S., Gharai, B., Mullapudi Venkata Rama, S. S., Kumar
Sundaran, R., and Wang, W.: Retrieval of CO<inline-formula><mml:math id="M452" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, CH<inline-formula><mml:math id="M453" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula>, CO and N<inline-formula><mml:math id="M454" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O using ground-
based FTIR data and validation against satellite observations over the
Shadnagar, India, Atmos. Meas. Tech. Discuss., <ext-link xlink:href="https://doi.org/10.5194/amt-2019-7" ext-link-type="DOI">10.5194/amt-2019-7</ext-link>,
2019.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Persky(1995)</label><?label Persky?><mixed-citation>Persky, M. J.: A review of spaceborne infrared Fourier transform spectrometers for remote sensing, Rev. Sci. Instrum., 66, 4763–4797, <ext-link xlink:href="https://doi.org/10.1063/1.1146154" ext-link-type="DOI">10.1063/1.1146154</ext-link>, 1995.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Petri et al.(2012)</label><?label petri?><mixed-citation>Petri, C., Warneke, T., Jones, N., Ridder, T., Messerschmidt, J., Weinzierl, T., Geibel, M., and Notholt, J.: Remote sensing of CO<inline-formula><mml:math id="M455" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and CH<inline-formula><mml:math id="M456" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula> using solar absorption spectrometry with a low resolution spectrometer, Atmos. Meas. Tech., 5, 1627–1635, <ext-link xlink:href="https://doi.org/10.5194/amt-5-1627-2012" ext-link-type="DOI">10.5194/amt-5-1627-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Razavi et al.(2009)</label><?label ravazi?><mixed-citation>Razavi, A., Clerbaux, C., Wespes, C., Clarisse, L., Hurtmans, D., Payan, S., Camy-Peyret, C., and Coheur, P. F.: Characterization of methane retrievals from the IASI space-borne sounder, Atmos. Chem. Phys., 9, 7889–7899, <ext-link xlink:href="https://doi.org/10.5194/acp-9-7889-2009" ext-link-type="DOI">10.5194/acp-9-7889-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Revercomb et al.(1988)</label><?label Revercomb:88?><mixed-citation>Revercomb, H. E., Buijs, H., Howell, H. B., LaPorte, D. D., Smith, W. L., and Sromovsky, L. A.: Radiometric calibration of IR Fourier transform spectrometers: solution to a problem with the High-Resolution Interferometer Sounder, Appl. Optics, 27, 3210–3218, <ext-link xlink:href="https://doi.org/10.1364/AO.27.003210" ext-link-type="DOI">10.1364/AO.27.003210</ext-link>, 1988.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx19"><label>Rodgers(2000)</label><?label rodgers?><mixed-citation>Rodgers, C. D.: Inverse Methods for Atmospheric Sounding – Theory and Practice, Series on Atmospheric Oceanic and Planetary Physics, vol. 2, World Scientific Publishing Co. Pte. Ltd, Singapore, <ext-link xlink:href="https://doi.org/10.1142/9789812813718" ext-link-type="DOI">10.1142/9789812813718</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Schmidt and Khedim (1991)</label><?label Schmidt1991?><mixed-citation>Schmidt, U. and Khedim, A.: In situ measurements of carbon dioxide in the winter Arctic vortex and at midlatitudes:  an indicator of the age of stratopheric air, Geophys. Res. Lett., 18, 763–766, <ext-link xlink:href="https://doi.org/10.1029/91GL00022" ext-link-type="DOI">10.1029/91GL00022</ext-link>, 1991.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Schneider and Hase(2008)</label><?label schneider?><mixed-citation>Schneider, M. and Hase, F.: Technical Note: Recipe for monitoring of total ozone with a precision of around 1 DU applying mid-infrared solar absorption spectra, Atmos. Chem. Phys., 8, 63–71, <ext-link xlink:href="https://doi.org/10.5194/acp-8-63-2008" ext-link-type="DOI">10.5194/acp-8-63-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Suto et al.(2006)</label><?label tanso-gen?><mixed-citation>
Suto, H., Kuze, A., Kaneko, Y., and Hamazaki, T.: Characterization of TANSO-FTS on GOSAT, AGU Fall Meeting Abstracts, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Toon(2015)</label><?label toon?><mixed-citation>Toon, G. C.: Solar Line List for the TCCON 2014 Data Release, CaltechDATA, <ext-link xlink:href="https://doi.org/10.14291/tccon.ggg2014.solar.r0/1221658" ext-link-type="DOI">10.14291/tccon.ggg2014.solar.r0/1221658</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx24"><label>Trishchenko(2006)</label><?label Trishchenko?><mixed-citation>Trishchenko, A. P.: Solar Irradiance and Effective Brightness Temperature for SWIR Channels of AVHRR/NOAA and GOES Imagers, J. Atmos. Ocean. Tech., 23, 198–210, <ext-link xlink:href="https://doi.org/10.1175/JTECH1850.1" ext-link-type="DOI">10.1175/JTECH1850.1</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Wiacek et al.(2007)</label><?label wiacek?><mixed-citation>Wiacek, A., Taylor, J. R., Strong, K., Saari, R., Kerzenmacher, T. E.,
Jones, N. B., and Griffith, D. W. T.: Ground-Based Solar Absorption FTIR
Spectroscopy: Characterization of Retrievals and First Results from a Novel
Optical Design Instrument at a New NDACC Complementary Station, J. Atmos. Ocean. Tech., 24, 432–448, <ext-link xlink:href="https://doi.org/10.1175/JTECH1962.1" ext-link-type="DOI">10.1175/JTECH1962.1</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Wunch et al.(2011)</label><?label tccon?><mixed-citation>Wunch, D., Toon, G. C., Blavier, J.-F. L., Washenfelder, R. A., Notholt, J., Connor, B. J., Griffith, D. W. T., Sherlock, V., and Wennberg, P. O.: The Total Carbon Column Observing Network, Philos. T. R. Soc. A, 369, 2087–2112, <ext-link xlink:href="https://doi.org/10.1098/rsta.2010.0240" ext-link-type="DOI">10.1098/rsta.2010.0240</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Zhou et al.(2019)</label><?label zhou?><mixed-citation>Zhou, M., Langerock, B., Sha, M. K., Kumps, N., Hermans, C., Petri, C., Warneke, T., Chen, H., Metzger, J.-M., Kivi, R., Heikkinen, P., Ramonet, M., and De Mazière, M.: Retrieval of atmospheric CH<inline-formula><mml:math id="M457" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula> vertical information from ground-based FTS near-infrared spectra, Atmos. Meas. Tech., 12, 6125–6141, <ext-link xlink:href="https://doi.org/10.5194/amt-12-6125-2019" ext-link-type="DOI">10.5194/amt-12-6125-2019</ext-link>, 2019.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Instrumental characteristics and potential greenhouse gas measurement capabilities of the Compact High-Spectral-Resolution Infrared Spectrometer: CHRIS</article-title-html>
<abstract-html><p>Ground-based high-spectral-resolution infrared measurements are an
efficient way to obtain accurate tropospheric abundances of different
gaseous species, in particular greenhouse gases (GHGs) such as
CO<sub>2</sub> and CH<sub>4</sub>. Many ground-based spectrometers are used
in the NDACC and TCCON networks to validate the Level 2 satellite
data, but their large dimensions and heavy mass make them inadequate
for field campaigns. To overcome these problems, the use of portable
spectrometers was recently investigated. In this context, this paper
deals with the CHRIS (Compact High-Spectral-Resolution Infrared
Spectrometer) prototype with unique characteristics such as its high
spectral resolution (0.135&thinsp;cm<sup>−1</sup> nonapodized) and its wide
spectral range (680 to 5200&thinsp;cm<sup>−1</sup>). Its main objective is
the characterization of gases and aerosols in the thermal and
shortwave infrared regions. That is why it requires high radiometric
precision and accuracy, which are achieved by performing spectral and
radiometric calibrations that are described in this paper. Furthermore,
CHRIS's capabilities to retrieve vertical CO<sub>2</sub> and CH<sub>4</sub>
profiles are presented through a complete information content
analysis, a channel selection and an error budget estimation in the
attempt to join ongoing campaigns such as MAGIC (Monitoring of
Atmospheric composition and Greenhouse gases through multi-Instruments
Campaigns) to monitor GHGs and validate the actual and future
space missions such as IASI-NG and Microcarb.</p></abstract-html>
<ref-html id="bib1.bib1"><label>Aumann et al.(2003)</label><mixed-citation>
Aumann, H. H., Chahine, M. T., Gautier, C., Goldberg, M. D., Kalnay, E.,
McMillin L. M., Revercomb, H., Rosenkranz, P. W., Smith, W. L.,
Staelin, D. H., Strow, L. L., and Susskind, J.: AIRS/AMSU/HSB on the Aqua mission: design, science objectives, data products, and processing systems, IEEE T. Geosci. Remote, 41, 253–264, <a href="https://doi.org/10.1109/TGRS.2002.808356" target="_blank">https://doi.org/10.1109/TGRS.2002.808356</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Clarisse et al.(2010)</label><mixed-citation>
Clarisse, L., Hurtmans, D., Prata, A. J., Karagulian, F., Clerbaux, C., Mazière, M. D., and Coheur, P.-F.: Retrieving radius, concentration, optical depth, and mass of different types of aerosols from high-resolution infrared nadir spectra, Appl. Optics, 49, 3713–3722, <a href="https://doi.org/10.1364/AO.49.003713" target="_blank">https://doi.org/10.1364/AO.49.003713</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Clerbaux et al.(2007)</label><mixed-citation>
Clerbaux, C., Hadji-Lazaro, J., Turquety, S., George, M., Coheur, P.-F., Hurtmans, D., Wespes, C., Herbin, H., Blumstein, D., Tourniers, B., and Phulpin, T.: The IASI/MetOp1 Mission: First observations and highlights of its potential contribution to GMES2, Space Res. Today, 168, 19–24, <a href="https://doi.org/10.1016/S0045-8732(07)80046-5" target="_blank">https://doi.org/10.1016/S0045-8732(07)80046-5</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Clough et al.(2005)</label><mixed-citation>
Clough, S. A., Shephard, M. W., Mlawer, E. J., Delamere, J. S., Iacono, M. J.,
Cady-Pereira, K., Boukabara, S., and Brown, P. D.: Atmospheric radiative
transfer modeling: a summary of the AER codes, J. Quant. Spectrosc. Ra., 91, 233–244, <a href="https://doi.org/10.1016/j.jqsrt.2004.05.058" target="_blank">https://doi.org/10.1016/j.jqsrt.2004.05.058</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>De Wachter et al.(2017)</label><mixed-citation>
De Wachter, E., Kumps, N., Vandaele, A. C., Langerock, B., and De Mazière, M.: Retrieval and validation of MetOp/IASI methane, Atmos. Meas. Tech., 10, 4623–4638, <a href="https://doi.org/10.5194/amt-10-4623-2017" target="_blank">https://doi.org/10.5194/amt-10-4623-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Dohe et al.(2013)</label><mixed-citation>
Dohe, S., Sherlock, V., Hase, F., Gisi, M., Robinson, J., Sepúlveda, E., Schneider, M., and Blumenstock, T.: A method to correct sampling ghosts in historic near-infrared Fourier transform spectrometer (FTS) measurements, Atmos. Meas. Tech., 6, 1981–1992, <a href="https://doi.org/10.5194/amt-6-1981-2013" target="_blank">https://doi.org/10.5194/amt-6-1981-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Eguchi et al.(2010)</label><mixed-citation>
Eguchi, N., Saito, R., Saeki, T., Nakatsuka, Y., Belikov, D., and
Maksyutov, S.:  A priori covariance estimation for CO<sub>2</sub> and
CH<sub>4</sub> retrievals, J. Geophys. Res., 115, D10215,
<a href="https://doi.org/10.1029/2009JD013269" target="_blank">https://doi.org/10.1029/2009JD013269</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Gisi et al.(2012)</label><mixed-citation>
Gisi, M., Hase, F., Dohe, S., Blumenstock, T., Simon, A., and Keens, A.: XCO<sub>2</sub>-measurements with a tabletop FTS using solar absorption spectroscopy, Atmos. Meas. Tech., 5, 2969–2980, <a href="https://doi.org/10.5194/amt-5-2969-2012" target="_blank">https://doi.org/10.5194/amt-5-2969-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Gordon et al.(2017)</label><mixed-citation>
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K., Drouin, B. J., Flaud, J.-M., Gamache, R. R., Hodges, J. T., Jacquemart, D., Perevalov, V. I., Perrin, A., Shine, K. P., Smith, M.-A. H., Tennyson, J., Toon, G. C., Tran, H., Tyuterev, V. G., Barbe, A., Császár, A. G., Devi, V. M., Furtenbacher, T., Harrison, J. J., Hartmann, J.-M., Jolly, A., Johnson, T. J., Karman, T., Kleiner, I., Kyuberis, A. A., Loos, J., Lyulin, O. M., Massie, S. T., Mikhailenko, S. N., Moazzen-Ahmadi, N., Muller, H. S. P., Naumenko, O. V., Nikitin, A. V., Polyansky, O. L., Rey, M., Rotger, M., Sharpe, S. W., Sung, K., Starikova, E., Tashkun, S. A., Auwera, J. V., Wagner, G., Wilzewski, J., Wcislo, P., Yu, S., and Zak, E. J.: The HITRAN2016 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 203, 3–69, <a href="https://doi.org/10.1016/j.jqsrt.2017.06.038" target="_blank">https://doi.org/10.1016/j.jqsrt.2017.06.038</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Herbin et al.(2013a)</label><mixed-citation>
Herbin, H., Labonnote, L. C., and Dubuisson, P.: Multispectral information
from TANSO-FTS instrument – Part 1: Application to greenhouse gases (CO<sub>2</sub> and CH<sub>4</sub>) in clear sky conditions, Atmos. Meas. Tech., 6, 3301–3311, <a href="https://doi.org/10.5194/amt-6-3301-2013" target="_blank">https://doi.org/10.5194/amt-6-3301-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Kobayashi et al.(2010)</label><mixed-citation>
Kobayashi, N., Inoue, G., Kawasaki, M., Yoshioka, H., Minomura, M., Murata, I., Nagahama, T., Matsumi, Y., Tanaka, T., Morino, I., and Ibuki, T.: Remotely operable compact instruments for measuring atmospheric CO<sub>2</sub> and CH<sub>4</sub> column densities at surface monitoring sites, Atmos. Meas. Tech., 3, 1103–1112, <a href="https://doi.org/10.5194/amt-3-1103-2010" target="_blank">https://doi.org/10.5194/amt-3-1103-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>L'Ecuyer et al.(2006)</label><mixed-citation>
L'Ecuyer, T. S., Gabriel, P., Leesman, K., Cooper, S. J., and Stephens, G. L.: Objective Assessment of the Information Content of Visible and Infrared Radiance Measurements for Cloud Microphysical Property Retrievals over the Global Oceans. Part I: Liquid Clouds, J. Appl. Meteorol. Clim., 45, 20–41, <a href="https://doi.org/10.1175/JAM2326.1" target="_blank">https://doi.org/10.1175/JAM2326.1</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Michalsky(1988)</label><mixed-citation>
Michalsky, J. J.: The Astronomical Almanac's algorithm for approximate solar position (1950–2050), J. Sol. Energ., 40, 227–235, <a href="https://doi.org/10.1016/0038-092X(88)90045-X" target="_blank">https://doi.org/10.1016/0038-092X(88)90045-X</a>, 1988.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Pathatoki et al.(2019)</label><mixed-citation>
Pathakoti, M., Gaddamidi, S., Gharai, B., Mullapudi Venkata Rama, S. S., Kumar
Sundaran, R., and Wang, W.: Retrieval of CO<sub>2</sub>, CH<sub>4</sub>, CO and N<sub>2</sub>O using ground-
based FTIR data and validation against satellite observations over the
Shadnagar, India, Atmos. Meas. Tech. Discuss., <a href="https://doi.org/10.5194/amt-2019-7" target="_blank">https://doi.org/10.5194/amt-2019-7</a>,
2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Persky(1995)</label><mixed-citation>
Persky, M. J.: A review of spaceborne infrared Fourier transform spectrometers for remote sensing, Rev. Sci. Instrum., 66, 4763–4797, <a href="https://doi.org/10.1063/1.1146154" target="_blank">https://doi.org/10.1063/1.1146154</a>, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Petri et al.(2012)</label><mixed-citation>
Petri, C., Warneke, T., Jones, N., Ridder, T., Messerschmidt, J., Weinzierl, T., Geibel, M., and Notholt, J.: Remote sensing of CO<sub>2</sub> and CH<sub>4</sub> using solar absorption spectrometry with a low resolution spectrometer, Atmos. Meas. Tech., 5, 1627–1635, <a href="https://doi.org/10.5194/amt-5-1627-2012" target="_blank">https://doi.org/10.5194/amt-5-1627-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Razavi et al.(2009)</label><mixed-citation>
Razavi, A., Clerbaux, C., Wespes, C., Clarisse, L., Hurtmans, D., Payan, S., Camy-Peyret, C., and Coheur, P. F.: Characterization of methane retrievals from the IASI space-borne sounder, Atmos. Chem. Phys., 9, 7889–7899, <a href="https://doi.org/10.5194/acp-9-7889-2009" target="_blank">https://doi.org/10.5194/acp-9-7889-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Revercomb et al.(1988)</label><mixed-citation>
Revercomb, H. E., Buijs, H., Howell, H. B., LaPorte, D. D., Smith, W. L., and Sromovsky, L. A.: Radiometric calibration of IR Fourier transform spectrometers: solution to a problem with the High-Resolution Interferometer Sounder, Appl. Optics, 27, 3210–3218, <a href="https://doi.org/10.1364/AO.27.003210" target="_blank">https://doi.org/10.1364/AO.27.003210</a>, 1988.

</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Rodgers(2000)</label><mixed-citation>
Rodgers, C. D.: Inverse Methods for Atmospheric Sounding – Theory and Practice, Series on Atmospheric Oceanic and Planetary Physics, vol. 2, World Scientific Publishing Co. Pte. Ltd, Singapore, <a href="https://doi.org/10.1142/9789812813718" target="_blank">https://doi.org/10.1142/9789812813718</a>, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Schmidt and Khedim (1991)</label><mixed-citation>
Schmidt, U. and Khedim, A.: In situ measurements of carbon dioxide in the winter Arctic vortex and at midlatitudes:  an indicator of the age of stratopheric air, Geophys. Res. Lett., 18, 763–766, <a href="https://doi.org/10.1029/91GL00022" target="_blank">https://doi.org/10.1029/91GL00022</a>, 1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Schneider and Hase(2008)</label><mixed-citation>
Schneider, M. and Hase, F.: Technical Note: Recipe for monitoring of total ozone with a precision of around 1 DU applying mid-infrared solar absorption spectra, Atmos. Chem. Phys., 8, 63–71, <a href="https://doi.org/10.5194/acp-8-63-2008" target="_blank">https://doi.org/10.5194/acp-8-63-2008</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Suto et al.(2006)</label><mixed-citation>
Suto, H., Kuze, A., Kaneko, Y., and Hamazaki, T.: Characterization of TANSO-FTS on GOSAT, AGU Fall Meeting Abstracts, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Toon(2015)</label><mixed-citation>
Toon, G. C.: Solar Line List for the TCCON 2014 Data Release, CaltechDATA, <a href="https://doi.org/10.14291/tccon.ggg2014.solar.r0/1221658" target="_blank">https://doi.org/10.14291/tccon.ggg2014.solar.r0/1221658</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Trishchenko(2006)</label><mixed-citation>
Trishchenko, A. P.: Solar Irradiance and Effective Brightness Temperature for SWIR Channels of AVHRR/NOAA and GOES Imagers, J. Atmos. Ocean. Tech., 23, 198–210, <a href="https://doi.org/10.1175/JTECH1850.1" target="_blank">https://doi.org/10.1175/JTECH1850.1</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Wiacek et al.(2007)</label><mixed-citation>
Wiacek, A., Taylor, J. R., Strong, K., Saari, R., Kerzenmacher, T. E.,
Jones, N. B., and Griffith, D. W. T.: Ground-Based Solar Absorption FTIR
Spectroscopy: Characterization of Retrievals and First Results from a Novel
Optical Design Instrument at a New NDACC Complementary Station, J. Atmos. Ocean. Tech., 24, 432–448, <a href="https://doi.org/10.1175/JTECH1962.1" target="_blank">https://doi.org/10.1175/JTECH1962.1</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Wunch et al.(2011)</label><mixed-citation>
Wunch, D., Toon, G. C., Blavier, J.-F. L., Washenfelder, R. A., Notholt, J., Connor, B. J., Griffith, D. W. T., Sherlock, V., and Wennberg, P. O.: The Total Carbon Column Observing Network, Philos. T. R. Soc. A, 369, 2087–2112, <a href="https://doi.org/10.1098/rsta.2010.0240" target="_blank">https://doi.org/10.1098/rsta.2010.0240</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Zhou et al.(2019)</label><mixed-citation>
Zhou, M., Langerock, B., Sha, M. K., Kumps, N., Hermans, C., Petri, C., Warneke, T., Chen, H., Metzger, J.-M., Kivi, R., Heikkinen, P., Ramonet, M., and De Mazière, M.: Retrieval of atmospheric CH<sub>4</sub> vertical information from ground-based FTS near-infrared spectra, Atmos. Meas. Tech., 12, 6125–6141, <a href="https://doi.org/10.5194/amt-12-6125-2019" target="_blank">https://doi.org/10.5194/amt-12-6125-2019</a>, 2019.
</mixed-citation></ref-html>--></article>