<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-14-4255-2021</article-id><title-group><article-title>A multi-purpose, multi-rotor drone system for long-range and high-altitude volcanic gas plume measurements</article-title><alt-title>A drone system for long-range and high-altitude volcanic gas plume measurements</alt-title>
      </title-group><?xmltex \runningtitle{A drone system for long-range and high-altitude volcanic gas plume measurements}?><?xmltex \runningauthor{B.~Galle~et~al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Galle</surname><given-names>Bo</given-names></name>
          <email>bo.galle@chalmers.se</email>
        <ext-link>https://orcid.org/0000-0001-9989-809X</ext-link></contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Arellano</surname><given-names>Santiago</given-names></name>
          <email>santiago.arellano@chalmers.se</email>
        <ext-link>https://orcid.org/0000-0002-0306-3782</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2 aff3">
          <name><surname>Bobrowski</surname><given-names>Nicole</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Conde</surname><given-names>Vladimir</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Fischer</surname><given-names>Tobias P.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Gerdes</surname><given-names>Gustav</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Gutmann</surname><given-names>Alexandra</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Hoffmann</surname><given-names>Thorsten</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Itikarai</surname><given-names>Ima</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff8">
          <name><surname>Krejci</surname><given-names>Tomas</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff9 aff10">
          <name><surname>Liu</surname><given-names>Emma J.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Mulina</surname><given-names>Kila</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4 aff11">
          <name><surname>Nowicki</surname><given-names>Scott</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff12">
          <name><surname>Richardson</surname><given-names>Tom</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Rüdiger</surname><given-names>Julian</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff12">
          <name><surname>Wood</surname><given-names>Kieran</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-5804-7704</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Xu</surname><given-names>Jiazhi</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Department of Earth, Space and Environment, Chalmers University of Technology, 41296, Gothenburg, Sweden</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Institute for Environmental Physics, University of Heidelberg, 69120 Heidelberg, Germany</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Max Planck Institute for Chemistry, 55128 Mainz, Germany</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Department of Earth and Planetary Sciences, University of New Mexico, Albuquerque, NM 87131, USA</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>Gerdes solutions AB, 128 41, Stockholm, Sweden</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Department of Chemistry, Johannes Gutenberg University, 55099 Mainz, Germany</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>Rabaul Volcano Observatory, P.O. Box 386, Rabaul, Papua New Guinea</institution>
        </aff>
        <aff id="aff8"><label>8</label><institution>HAB Electronic AB, 34140, Ljungby, Sweden</institution>
        </aff>
        <aff id="aff9"><label>9</label><institution>Department of Earth Sciences, University of Cambridge, Cambridge, CB2 3EQ, UK</institution>
        </aff>
        <aff id="aff10"><label>10</label><institution>Department of Earth Sciences, University College London, London, WC1E 6BS, UK</institution>
        </aff>
        <aff id="aff11"><label>11</label><institution>Quantum Spatial, Inc., Albuquerque, NM, USA</institution>
        </aff>
        <aff id="aff12"><label>12</label><institution>Department of Aerospace Engineering, University of Bristol, Bristol, BS8 1TR, UK</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Bo Galle (bo.galle@chalmers.se) and Santiago Arellano (santiago.arellano@chalmers.se)</corresp></author-notes><pub-date><day>9</day><month>June</month><year>2021</year></pub-date>
      
      <volume>14</volume>
      <issue>6</issue>
      <fpage>4255</fpage><lpage>4277</lpage>
      <history>
        <date date-type="received"><day>11</day><month>November</month><year>2020</year></date>
           <date date-type="accepted"><day>26</day><month>April</month><year>2021</year></date>
           <date date-type="rev-recd"><day>10</day><month>March</month><year>2021</year></date>
           <date date-type="rev-request"><day>14</day><month>December</month><year>2020</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2021 Bo Galle et al.</copyright-statement>
        <copyright-year>2021</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021.html">This article is available from https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e307">A multi-rotor drone has been adapted for studies of volcanic gas plumes. This adaptation includes improved capacity for high-altitude and long-range, real-time <inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration monitoring, long-range manual control, remotely activated bag sampling and plume speed measurement
capability. The drone is capable of acting as a stable platform for various instrument configurations, including multi-component gas analysis system (MultiGAS) instruments for in situ
measurements of <inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations in the gas plume and portable differential optical absorption spectrometer (MobileDOAS) instruments for spectroscopic
measurement of total <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emission rate, remotely controlled gas sampling in bags and sampling with gas denuders for posterior analysis on
the ground of isotopic composition and halogens.</p>
    <p id="d1e367">The platform we present was field-tested during three campaigns in Papua New Guinea: in 2016 at Tavurvur, Bagana and Ulawun volcanoes, in 2018
at Tavurvur and Langila volcanoes and in 2019 at Tavurvur and Manam volcanoes, as well as in Mt. Etna in Italy in 2017.</p>
    <p id="d1e370">This paper describes the drone platform and the multiple payloads, the various measurement strategies and an algorithm to correct for different
response times of MultiGAS sensors. Specifically, we emphasize the need for an adaptive flight path, together with live data transmission of a plume
tracer (such as <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration) to the ground station, to ensure optimal plume interception when operating beyond the visual line of
sight. We present results from a comprehensive plume characterization obtained during a field deployment at Manam volcano in May 2019. The Papua New
Guinea region, and particularly Manam volcano, has not been extensively studied for volcanic gases due to its remote location, inaccessible summit
region and high level of volcanic activity. We demonstrate that the combination of a multi-rotor drone with modular payloads is a versatile solution to
obtain the flux and composition of volcanic plumes, even for the case of a highly active volcano with a high-altitude plume such as
Manam. Drone-based measurements offer a valuable solution to volcano research and monitoring applications and provide an alternative<?pagebreak page4256?> and
complementary method to ground-based and direct sampling of volcanic gases.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
<sec id="Ch1.S1.SS1">
  <label>1.1</label><title>The use of drones for studies of volcanic plumes</title>
      <p id="d1e400">The use of drones for volcanic plume studies was pioneered by Faivre-Pierret et al. (1980), who employed a fixed-wing drone equipped with in situ
sensors to measure the composition of the volcanic plume of Mt. Etna, together with correlation-spectrometry-derived (COSPEC; Stoiber et al., 1983) fluxes of <inline-formula><mml:math id="M7" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M8" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, HCl and HF. This was an unmanned research aircraft that demanded high expertise and complex field
operations. More recently, McGonigle et al. (2008) employed an unmanned helicopter equipped
alternatively with a multi-component gas analysis system (MultiGAS; Aiuppa et al., 2005; Shinohara,
2005) and a portable differential optical absorption spectrometer (MobileDOAS; Galle et al., 2003)
system to measure the flux of <inline-formula><mml:math id="M9" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> from the crater rim of Vulcano Island, Italy. This was a proof-of-concept study that
demonstrated the utility of a commercial system to acquire proximal measurements, although the vehicle still required a level of piloting
expertise. The first use of a multi-rotor platform capable of reaching a high-elevation plume was reported by Mori et al. (2016), who performed
measurements with a multi-rotor drone in the eruptive plume of Ontake volcano and measured <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> and
HCl concentrations, employing a combination of MultiGAS and MobileDOAS instruments. The authors reported various problems, such as the need to properly
shield electrochemical sensors used in MultiGAS units from electromagnetic interference derived from the drone motors or radio telemetry. Similar work
was conducted by Rüdiger et al. (2018), who measured the plumes of Masaya, Stromboli and Turrialba volcanoes and studied the ageing of halogenic
species using drone-mounted denuder samplers. De Moor et al. (2019) and Stix et al. (2018) used a
multi-rotor drone to perform MultiGAS and MobileDOAS measurements and to collect plume samples for posterior carbon isotopic speciation analyses. They also
measured plume speed by letting the drone drift freely with the winds at plume level. Mandon et al. (2019) also used a multi-rotor drone and a sampling
unit to collect high-temperature filter pack samples of volcanic gases at White Island volcano, which were characterized geochemically, focusing on the
composition of trace metal aerosols. At Villarrica, comparison of the plume chemistry measured directly above the lava lake (using a drone-mounted gas
analyser) and downwind on the crater rim (using a traditional ground-based instrument) simultaneously showed how volcanic plumes can dilute and
homogenize over short distances of <inline-formula><mml:math id="M15" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 150 <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, especially in turbulent crater environments (Liu et al., 2019). Furthermore, Schellenberg
et al. (2019) described in-plume ash collection at long range using fixed-wing vehicles at Fuego volcano (Guatemala), and Syahbana et al. (2019)
launched a fixed-wing aircraft with sensors for <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> that were essential for a successful assessment of
eruptive activity of Mt. Agung in 2017. This short account is intended to highlight representative studies using drones as platforms for volcanic
plume measurements; more comprehensive reviews, including the broader applications of drones in volcanology, can be found in Villa et al. (2016) or
James et al. (2020).</p>
      <p id="d1e549">The above-mentioned studies show different aspects of the capabilities of drones to reach volcanic plumes and vents and perform measurements with
various levels of complexity. Our study combines multiple aspects of these independent developments to show that the same unit can be used to achieve
the above-mentioned goals in a single field experiment, with maximum field operability in terms of portability and a reduced number of people required
for the measurement, i.e. usually only two. These features make our approach a practical solution to expand the use of drones for routine monitoring
of volcanic plumes.</p>
</sec>
<sec id="Ch1.S1.SS2">
  <label>1.2</label><title>Manam volcano</title>
      <p id="d1e560">Manam volcano, located in Papua New Guinea, is the highest volcano in the Bismarck arc. The volcano is a 3000 <inline-formula><mml:math id="M20" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> high composite volcano that
rises about 1800 <inline-formula><mml:math id="M21" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula> (above mean sea level). The island of Manam is about 10 <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula> in diameter. Manam has erupted about 40 times
since the early 1600s. The current phase of eruptive activity began in June 2014 and continues to date of writing, characterized by sporadic VEI4
eruptions superimposed on persistent passive degassing and minor explosive activity (Venzke, 2013). In 2004, an eruption devastated large sectors of
the island and displaced thousands of people to the mainland (Liu et al., 2020). Manam is currently
ranked as one of the top 10 <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emitters in the world and degassed about 1 <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Mt</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">a</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> during 2005–2015
based on petrological proxies to estimate the <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux (Aiuppa et al., 2019; Fischer et al., 2019).</p>
      <p id="d1e661">Manam is an archetypical case that represents the challenges of obtaining detailed information on volcanic plumes for a large proportion of volcanoes in
the world. Indeed, our present knowledge of the composition and flux of gas emissions from volcanoes is limited due to the same reasons described
above: remote location, explosive activity or inaccessible vents and plumes. Although satellite-based remote-sensing instruments have a large
potential to overcome these limitations, this approach is in general only valid for <inline-formula><mml:math id="M27" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> because its atmospheric background concentration is
low compared to the volcanic signal. For most other species, in situ measurements are the only option, when feasible. From a total of nearly 1500
Holocene volcanoes listed in the Smithsonian Institution's Global Volcanism Program database
(<uri>https://volcano.si.edu/list_volcano_holocene.cfm</uri>,<?pagebreak page4257?> last access: 4 June 2021), about 50 % have a summit altitude above
2 <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula> Nearly 100 of the Holocene volcanoes had a flux of <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> above the Ozone Monitoring Instrument (OMI) 1 year-average
threshold of about 40 <inline-formula><mml:math id="M30" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">t</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">d</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (Carn et al., 2017) during 2005–2016, of which <inline-formula><mml:math id="M31" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 60 % have a summit at 2 <inline-formula><mml:math id="M32" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula> or
higher. Therefore, a drone-based platform for gas sampling or real-time measurement of volcanic species in the plume needs to be suitable to reach
plumes at high elevation where air density is low and robust enough to sustain harsh measurement conditions such as acidity, corrosion and
turbulence that are encountered in dense regions of the plume. Thus, Manam volcano is a suitable volcano for demonstrating the challenging use of a drone in
volcano gas monitoring, and for this reason it was chosen as the target of a field campaign (Aerial Based Observations of Volcanic Emissions, ABOVE; Liu et al., 2020) to characterize this strong, yet
difficult-to-access, volcanic plume.</p>
</sec>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>The drone platform</title>
      <p id="d1e780">We designed our system to fulfil the following demands:
<list list-type="bullet"><list-item>
      <p id="d1e785">capability to measure in situ concentrations in excess of a few parts per million (ppm) above ambient for several components of the plume: <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math id="M34" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M35" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula> in real time;</p></list-item><list-item>
      <p id="d1e824">capability to measure the flux of all major volcanic species in the plume, <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with direct measurement and the other gases after
obtaining their ratio against <inline-formula><mml:math id="M37" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and combination with <inline-formula><mml:math id="M38" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux;</p></list-item><list-item>
      <p id="d1e861">capability to collect physical bag samples of the volcanic plume, for posterior chemical or isotopic analysis (of carbon or other species) on
the ground;</p></list-item><list-item>
      <p id="d1e865">capability to reach altitudes higher than 2 <inline-formula><mml:math id="M39" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula> above take-off altitude and ranges of the order of 5 <inline-formula><mml:math id="M40" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>;</p></list-item><list-item>
      <p id="d1e885">relatively low-cost, low-expertise threshold to operate and high field robustness and portability.</p></list-item></list></p>
      <p id="d1e888">With these demands in mind, we developed the following concept: a multi-rotor drone platform with modular payloads for different types of
measurement. We chose a hexa-copter in Y-shape configuration, the Micro model developed by Sky-Eye Innovations in Sweden, which we dubbed
“Munin”. Among the advantages of a multi-rotor configuration, we include (1) the possibility to hover, which is required for optimal positioning of
the drone in the plume, for collecting samples in a bag from a confined region and for measuring during a time long enough to guarantee a good signal;
(2) the possibility to perform measurements in the vertical direction, required to, for example, determine the concentration profile in the plume;
(3) high manoeuvrability to adapt to changing wind conditions and to chase high volcanic gas concentration regions of the plume; (4) high portability
due to its small size, low weight and foldable parts; and (5) simplicity for operation, usually not requiring expert piloting capabilities and no more than
two people. The main disadvantage of a battery-driven multi-rotor drone in comparison with combustion-powered (i.e. liquid fuel) platforms is a limited
flight time, which translates into a reduced time of measurement in the plume, especially at high altitudes and distances. A main disadvantage with
the combustion-powered platforms related to gas volcanic measurements is the risk of contamination, especially under hovering conditions.</p>
<sec id="Ch1.S2.SS1.SSS1">
  <label>2.1.1</label><title>Drone feasibility studies and lessons learnt</title>
      <p id="d1e898">The development of our drone platform was initially motivated by the goal to measure the <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emission from Bagana volcano, identified as one
of the strongest emitters of <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Carn et al., 2017), in 2016. The high level of activity of this remote volcano made it impossible for
people to reach its active vents for sampling, and to reach a plume at summit level required at least 1600 <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> of vertical climb above
ground. We tested an earlier version of our drone for high-altitude flights, in order to assess the maximum altitude achievable with a payload of
about 1 <inline-formula><mml:math id="M44" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi></mml:mrow></mml:math></inline-formula>. These tests were performed at the ESRANGE Space Center, which is operated by the Swedish Space Corporation and located near to
Kiruna, in northern Sweden. Loaded flights were done in vertical and horizontal trajectories to measure the current consumption during climb (at
5 <inline-formula><mml:math id="M45" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>), hovering, descent (at 4 <inline-formula><mml:math id="M46" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) and cruise (at 8 <inline-formula><mml:math id="M47" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). Typical currents for these flight modes were 54,
33, 22 and 30 <inline-formula><mml:math id="M48" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">A</mml:mi></mml:mrow></mml:math></inline-formula> (1200, 730, 490, 660 <inline-formula><mml:math id="M49" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">W</mml:mi></mml:mrow></mml:math></inline-formula>), respectively, during horizontal wind conditions of <inline-formula><mml:math id="M50" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 10 <inline-formula><mml:math id="M51" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. Vertical
ascents up to 1800 <inline-formula><mml:math id="M52" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> above ground were reached in these tests, above which radio control signal (at 2.4 <inline-formula><mml:math id="M53" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">GHz</mml:mi></mml:mrow></mml:math></inline-formula>) was lost. Using two
batteries, each consisting of 24 Li-ion cells (3.7 <inline-formula><mml:math id="M54" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula>, 2.5 <inline-formula><mml:math id="M55" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Ah</mml:mi></mml:mrow></mml:math></inline-formula> each) connected in a 6S4P configuration, gives a total battery capacity
of 20 <inline-formula><mml:math id="M56" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Ah</mml:mi></mml:mrow></mml:math></inline-formula>. For a conservative mean current consumption of 40 <inline-formula><mml:math id="M57" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">A</mml:mi></mml:mrow></mml:math></inline-formula>, this battery capacity allows for a nominal flight time of
30 <inline-formula><mml:math id="M58" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula>. After the experience gained from this study and field studies in Bagana and Ulawun (Northern Hemisphere (NH) autumn 2016), Etna (NH spring 2017) and Langila
(NH autumn 2018) volcanoes, the main lessons learnt were as follows.
<list list-type="bullet"><list-item>
      <p id="d1e1091">When ascending and moving horizontally, it was found that energy consumption could be reduced if the rise and forward motion were balanced in an
optimal way, as compared to moving only in one direction at a time. This is because a considerable horizontal component in the movement gives a lift
that reduces the energy consumption for maintaining the vertical position. An additional advantage is that the drone then flies in undisturbed air
with less turbulence compared to a clean vertical movement. When the drone flew into clouds, energy consumption increased by about 50 %. On
descent,<?pagebreak page4258?> it was found that stability deteriorated when descending through clouds; see Fig. 1. Therefore, we avoided clouds as much as possible
during flights. In the later part of the campaign, this was facilitated by using an onboard camera and flying with FPV (first-person view). The drone's
angle through the air, the tilt related to the ratio between horizontal and vertical motion, also proved to be of great importance for energy
consumption. Both during ascent and descent, energy consumption could be minimized by considering and taking advantage of the wind's strength and
direction. On the prevailing conditions at Manam, a tilt of 11<inline-formula><mml:math id="M59" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> from the horizon was found to be optimal for the decent.</p></list-item><list-item>
      <p id="d1e1104">The volcanic plumes were typically found to move both horizontally and vertically within a short time span. In order to be able to sample the
plume with in situ methods, it is crucial that the plume centre, having the densest gas concentrations, can be reached. Thus it is important to be
able to receive real-time information on the ground of a relevant plume tracer (<inline-formula><mml:math id="M60" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration) and to be able to control the remote drone
location from the ground and thereby adapt the flight path of the drone in response to this real-time data stream.</p></list-item><list-item>
      <p id="d1e1119">Electrical interference from motors and telemetry influenced the noise level of the electrochemical sensors. Thus shielding and location of
power and data cables, as well as location of antennas, were important (see hardware modifications detailed below).</p></list-item><list-item>
      <p id="d1e1123">It was found that the time needed for switching between different payloads could be considerably reduced by changes in the drone frame and
payload designs (balance, power connection, data access, telemetry). The batteries were mounted under the frame and could be changed with a
“click” locking. This enabled fast switching of batteries and improved the balance, especially at take-off and landing. The payloads were mounted
on individual plates that were locked in place on the drone platform with a click lock similar to what was used for the batteries and provided
by the drone manufacturer. This enabled the payloads to be pre-balanced, and no further balancing of the drone was needed after replacement of
payload. A special power output on the drone gave the payloads power and access to the drone-mounted telemetry. This power output was always turned
on to make it possible to do pre-flight and post-flight operations on the payload instrument without turning on the main drone electricity to save
power.</p></list-item><list-item>
      <p id="d1e1127">Access to the drone flight logs were found to be useful for post-flight analysis of power consumption with different flight modes, extraction of
wind information and backup data of basic parameters like pressure, temperature and position. An example of data from the flight log is given in
Fig. 1.</p></list-item></list></p>

      <?xmltex \floatpos{p}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e1132">Flight data from the drone flight shown in Fig. 9. The upper panels show time series of yaw, pitch and roll angles, the thrust (percentage) and the altitude of the drone. Notice the high variability of the parameters associated with acceleration, hovering and interference from clouds.</p></caption>
            <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f01.png"/>

          </fig>

      <?xmltex \floatpos{p}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e1143">Photo of the multi-rotor drone with modular payloads. The MultiGAS unit includes in situ sensors for gas composition (<inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi>A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> – concentration of species <inline-formula><mml:math id="M62" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M63" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula> – pressure, <inline-formula><mml:math id="M64" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> – temperature, %RH – relative humidity, <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mi>y</mml:mi><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> – tilt coordinates), a gas-sampling unit and an anemometer. The MobileDOAS is used for the remote sensing of the gas flux. The modules are clamped to the drone at balanced position. The battery pack is placed below the drone chassis to lower the centre of gravity of the system. Flight and sensor data are telemetered in real time (photo courtesy of Matthew Wordell).</p></caption>
            <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f02.jpg"/>

          </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e1200">Technical specifications of the hexa-copter.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Model</oasis:entry>
         <oasis:entry colname="col2">SkyEye Innovations Micro</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Nickname</oasis:entry>
         <oasis:entry colname="col2">Munin</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Configuration</oasis:entry>
         <oasis:entry colname="col2">Y6 multi-rotor (three pairs of co-axial, counter-rotating rotors in tandem)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Navigation system</oasis:entry>
         <oasis:entry colname="col2">PixHawk model V4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Remote control</oasis:entry>
         <oasis:entry colname="col2">Jeti DC16</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Camera system</oasis:entry>
         <oasis:entry colname="col2">OcuSync 2.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Drone size, folded (<inline-formula><mml:math id="M66" display="inline"><mml:mi>D</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M67" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M68" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M69" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M70" display="inline"><mml:mi>W</mml:mi></mml:math></inline-formula>) (<inline-formula><mml:math id="M71" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">80 <inline-formula><mml:math id="M72" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 20 <inline-formula><mml:math id="M73" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 23</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Frame weight, without batteries</oasis:entry>
         <oasis:entry colname="col2">3.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Drone weight, including batteries (<inline-formula><mml:math id="M74" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">4.5–6.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Maximum payload (<inline-formula><mml:math id="M75" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">2.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Maximum combined thrust (<inline-formula><mml:math id="M76" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">120</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Battery voltage (<inline-formula><mml:math id="M77" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">22.2 (6 <inline-formula><mml:math id="M78" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 3.7)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Battery capacity (<inline-formula><mml:math id="M79" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Ah</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">20 (2 <inline-formula><mml:math id="M80" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Control range (<inline-formula><mml:math id="M81" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Typical flight time (1 <inline-formula><mml:math id="M82" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">kg</mml:mi></mml:mrow></mml:math></inline-formula> payload) (min)</oasis:entry>
         <oasis:entry colname="col2">30</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Maximum climb speed (<inline-formula><mml:math id="M83" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Maximum descent speed (<inline-formula><mml:math id="M84" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">4</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Maximum cruise speed (still wind) (<inline-formula><mml:math id="M85" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">10</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1561">Based on these experiences, we modified the standard model of our platform in the following ways:
<list list-type="bullet"><list-item>
      <p id="d1e1566"><italic>Change of operative system</italic>. We adopted an open-source navigation module PixHawk V4 with its own power distribution card in order to
overcome typical restrictions in altitude and distance of other commercially available solutions, as well as to access all information of the
flight logs for posterior analysis.</p></list-item><list-item>
      <p id="d1e1572"><italic>Modifications in the frame design</italic>. These modifications include addition of a larger payload-carrying platform, the use of more robust motors
with race drone ESC (electronic speed control) that improves the manoeuvrability and propellers with a larger diameter than are typically standard for
a drone of this size (45 cm). We also placed the batteries below, instead of on top, of the main frame to gain further stability. The drone
has a triple inertial measurement unit (IMU), dual compass and one GPS and was provided with two 6S4P 10 <inline-formula><mml:math id="M86" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Ah</mml:mi></mml:mrow></mml:math></inline-formula> batteries.</p></list-item><list-item>
      <p id="d1e1586"><italic>Control board</italic>. Jeti DC16 was used as a pilot controller, and for transmission a Crossfire (TBS Crossfire Diversity Nano RX) was used. A tablet
was connected to the Crossfire for flight planning and for monitoring the telemetry.</p></list-item><list-item>
      <p id="d1e1592"><italic>Increased telemetry range</italic>. We replaced the common 2.4 <inline-formula><mml:math id="M87" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">GHz</mml:mi></mml:mrow></mml:math></inline-formula> by a 900 <inline-formula><mml:math id="M88" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">MHz</mml:mi></mml:mrow></mml:math></inline-formula> radio link and used a high-gain directional antenna for
ground control. Figure 2 shows a photo of the drone and its main modular payloads. Technical specifications of our drone are provided in Table 1.</p></list-item><list-item>
      <p id="d1e1614"><italic>Electrical interference</italic>. We used a shielded metal box for the electrochemical sensors and tested the optimal location of power and data cables
and antennas to minimize electrical interference on these detectors.</p></list-item><list-item>
      <p id="d1e1620"><italic>Camera</italic>. During the later part of the campaign at Manam, it was found to be useful to include a camera running in FPV (first-person view)
mode. The main reason for this was that it facilitated the avoidance of clouds and thereby reduced energy consumption. It also improved the
manoeuvrability as it gave the pilot access to critical parameters in real time within their view (goggles).</p></list-item></list></p>
      <p id="d1e1625">With these modifications we have been able to reach heights of 2000 <inline-formula><mml:math id="M89" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> above take off position (equivalent to absolute altitudes of up to
3700 <inline-formula><mml:math id="M90" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula>) and a range of nearly 5 <inline-formula><mml:math id="M91" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula>. Although we have limited the total flight time to 30 <inline-formula><mml:math id="M92" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula> under normal conditions
(i.e. those conditions resulting in normal current consumption), with favourable conditions and flight piloting strategies, a flight time of
35 <inline-formula><mml:math id="M93" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula> could be achieved within a safe margin. In the following sections, we describe each of the modular payloads and measurement strategies
compatible with this drone platform.</p>
</sec>
</sec>
<?pagebreak page4260?><sec id="Ch1.S2.SS2">
  <label>2.2</label><title>In situ measurements of plume speed</title>
      <p id="d1e1694">When determining the gas emission rate – using methods such as MobileDOAS (Galle et al., 2003), ScanDOAS (Edmonds et al., 2003) or COSPEC (Stoiber
et al., 1983) – information about the wind speed at plume height is critical. Since volcanic plumes are often located at several kilometres' altitude,
and the measurements are conducted in an area relatively close to a major topographic structure, acquiring representative measurements of plume speed
is challenging. The use of atmospheric models (such as operational databases provided by NOAA or ECMWF) is an alternative approach; however, these
models are usually coarse in horizontal, vertical and temporal resolutions, and thus validation of these modelled wind data by local measurements is
valuable. A drone can offer such in situ validation.</p>
      <p id="d1e1697">We have applied two different methods for plume speed measurements using the drone: drone drift and anemometer. In the drone drift method, the drone
is first positioned at the altitude of the plume, and then the GPS position-locking is deactivated. The drone is thus left free to drift with the
horizontal wind and, after an initial lag time of less than 1 min, the drone reaches the local wind speed. The movement of the drone is logged
with a separate GPS receiver, from which the local wind speed can be determined. Additionally, the actual airspeed can also be monitored in real time
through the information sent to ground control, derived from GPS data. In the second method, a small and lightweight anemometer was installed on the
drone, logging the total velocity experienced by the drone (wind velocity <inline-formula><mml:math id="M94" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> drone velocity). With the drone held in a fixed position close to the
plume, the plume speed is thus obtained. The advantage of this method over the drone drift approach is that plume speed may be derived at the same
time as other measurements in the plume are conducted. The anemometer is integrated with the MultiGAS unit, described below.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><?xmltex \opttitle{MobileDOAS for remote measurement of {$\protect\chem{SO_{{2}}}$} emission rate}?><title>MobileDOAS for remote measurement of <inline-formula><mml:math id="M95" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emission rate</title>
      <p id="d1e1727">Since 2002 an instrument referred to as MobileDOAS (Galle et al., 2003; Johansson, 2009) has
been used increasingly to replace the previously used COSPEC instrument (Stoiber et al., 1983) for measurements of volcanic <inline-formula><mml:math id="M96" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> gas emission
rate. Both MobileDOAS and COSPEC instruments use the diffused UV solar radiation as a light source for the determination of the total column of
<inline-formula><mml:math id="M97" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> above the instrument, which is calculated using absorption spectroscopy. During a typical measurement, the instrument is moved in such a
way that it passes under the gas plume in a direction close to perpendicular to the plume transport direction while simultaneously recording spectra
and GPS location. Thus, by correcting for deviations from traversing the plume perpendicularly using GPS data and using DOAS evaluation algorithms to
derive <inline-formula><mml:math id="M98" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> total columns along the track, the total number of <inline-formula><mml:math id="M99" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> molecules in a cross-section of the gas plume can be
derived. This quantity is then multiplied by wind speed at the centre of mass of the plume – i.e. plume speed – to derive the gas emission rate.</p>
      <p id="d1e1774">The main sources of error in these measurements are “dilution” of the absorption signal due to simultaneous collection of skylight that has been
either transmitted through the plume or scattered from outside of the plume (Millán, 1980; Mori et al., 2006) and limited knowledge of the plume speed (Galle et al.,
2010).</p>
      <?pagebreak page4261?><p id="d1e1777"><?xmltex \hack{\newpage}?>MobileDOAS measurements from a drone platform offer several advantages compared to traditional approaches (e.g. Rüdiger et al., 2018; De Moor
et al., 2019): regardless of infrastructure (roads) and topography, traverses can be made in a
direction perpendicular to the plume direction. Measurements can be made at an elevated altitude, thus reducing the effects of light dilution, and
plume speed can be determined reasonably accurately by the methods described in Sect. 2.2.</p>
      <p id="d1e1782">General details of the MobileDOAS hard- and software are given in Johansson et al. (2009). Details
specific to our drone-mountable version of the instrument are provided in Table A1 (Appendix A). A schematic view of the MobileDOAS instrument is
shown in Fig. 3.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e1787">Schematic layout of the MobileDOAS instrument.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f03.png"/>

        </fig>

      <p id="d1e1796">The MobileDOAS instrument is built into a plastic case with clamps adapted to a platform on the drone in a balanced position, and it is powered from a
12/5 <inline-formula><mml:math id="M100" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula> power cable from the drone that was permanently active. Thus, the MobileDOAS could be installed on the drone platform, and the
MobileDOAS software could be started up, or data from the MobileDOAS could be backed up, without the main drone power turned on, thereby saving battery
power. While the MobileDOAS software is active, a stream of basic information (time, position, <inline-formula><mml:math id="M101" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column density) is transmitted in real
time via an independent radio link from the instrument. These real-time data help the pilot to guide the drone and ensure a complete traverse of
the plume. The full traverse can be visualized upon landing, by connecting an external computer to the instrument computer running MobileDOAS.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><title>MultiGAS for in situ measurement of gas composition</title>
      <p id="d1e1826">MobileDOAS and ScanDOAS are used to obtain <inline-formula><mml:math id="M102" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> – and under some circumstances also BrO (Lübcke et al., 2014) – emission rates from the
ground using remote-sensing techniques. However, to obtain the relative concentrations of other volcanic species, such as <inline-formula><mml:math id="M103" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M104" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>, direct measurements must be conducted within the plume itself; high atmospheric background concentrations or weak optical absorption of
these species preclude robust detection by remote-sensing methods. The most common method used for this is multi-component gas analyser systems
(MultiGAS; Aiuppa et al., 2005; Shinohara, 2005). MultiGAS-type instruments generally consist of several small sensors (typically electrochemical or
optical), with low power consumption, connected to a micro-computer and sometimes a data link for real-time data transfer. The instrument is typically
installed in a gas-exposed location (e.g. a crater rim), often proximal to the vent location. Although its installation may be labour-intensive and
sometimes risky, this method is generally straightforward. However, on many volcanoes, approaching the summit area would represent an enormous risk –
this is the situation at Manam. In such cases, performing the in-plume measurements using a drone is an attractive possibility. An obvious requirement
here is the ability of the drone to reach high altitude as well as having long endurance. This is emphasized further by the fact that many of the
sensors used have slow response times, while the gas concentrations (especially close to the vent where the signal is stronger) may vary quickly
within seconds due to dilution and turbulent wind conditions. Under these conditions, it is preferable to expose the sensors to the volcanic gas for as
long a sampling duration as possible – ideally at least several minutes. Short time fluctuations in concentration and plume location also imply that
the ability to monitor a gas tracer (such as <inline-formula><mml:math id="M105" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) in real time is desirable to “chase” high-concentration sites. This is of course not
guaranteed when the drone is sent in autopilot, unless an adaptive flight routine based on a plume tracer is implemented.</p>
      <p id="d1e1875">MultiGAS units combine information from different sensors to determine the mixing ratios of different species. In our present system, these quantities
are determined according to the following processes:
<list list-type="bullet"><list-item>
      <p id="d1e1880"><italic>For</italic> <inline-formula><mml:math id="M106" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <italic>and</italic> <inline-formula><mml:math id="M107" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>. The target gas is pumped into a chamber to which the electrochemical sensors are exposed. The signal generated by the electrochemical effect from an
electrode exposed to the gas of interest is subtracted from the signal of a reference electrode inside the system This differential signal is
proportional to the gas mixing ratio. The proportionality is linear within a certain range and depends to some degree on temperature, pressure and
the concentration of interfering species. These proportionality and disturbance factors are determined by calibration.</p></list-item><list-item>
      <p id="d1e1913"><italic>For</italic> <inline-formula><mml:math id="M108" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.
<list list-type="bullet"><list-item>
      <p id="d1e1931">The same gas sample is passed through a cavity illuminated by two infrared beams with wavelengths centred in and out of an absorption band of
<inline-formula><mml:math id="M109" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.</p><?xmltex \hack{\newpage}?></list-item><list-item>
      <p id="d1e1947">Using Beer–Lambert's extinction law, the local concentration of <inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is determined.</p></list-item><list-item>
      <p id="d1e1962">To get the mixing ratio, further corrections are needed for temperature, pressure and relative humidity, which should be established by
calibration.</p></list-item></list></p></list-item></list></p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e1967">Schematic layout of the MultiGAS instrument.</p></caption>
          <?xmltex \igopts{width=384.112205pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f04.png"/>

        </fig>

      <p id="d1e1977">For the case of <inline-formula><mml:math id="M111" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, the mixing ratio can be derived from measured relative humidity, pressure and temperature, following known
thermodynamic laws (see Appendix B). If the measurement of such variables is done inside the sampling circuit, the <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> mixing ratio of the
sample can be determined simultaneously to the other species. Our system, however, measures these variables only inside the instrument box, so the
mixing ratio is representative of ambient gas passively diffusing in the interior of the unit; <inline-formula><mml:math id="M113" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> therefore varies differently than the
other species as it is determined from outside of the closed system. The schematic layout of the MultiGAS instrument used in this study is shown in
Fig. 4, and technical specifications of the sensors are given in Appendix A.</p>
      <p id="d1e2019">Data from this unit are transmitted through an independent data link and visualized on the ground using self-developed software used for tracking
emissions from ships (Beecken et al., 2015; Mellqvist et al., 2018). This visualization is the basis to fine-tune the position of the drone for
the sampling of more concentrated regions of the plume.</p>
      <p id="d1e2022">To obtain the mixing ratios representative of the volcanic emission, it is necessary to correct for the contribution from the same species present in
the background atmosphere. Ideally, such a measurement should be done at similar ambient conditions (i.e. pressures, temperature) to those expected
inside the plume, unless the corrections for different conditions are known precisely.</p>
      <p id="d1e2025">When two sensors have different response time characteristics, the signals they measure will have different amplitude and shape and be time-shifted
with respect to the input signals depending on the frequency content of the input. This “distortion” of the input signals can be large when a
rapidly fluctuating signal is measured for a short time; i.e. the instrument basically records only the transient signal. This could be the case with
MultiGAS measurements on a flying drone in a turbulent plume. These effects must be considered to reproduce the input signal and subsequently analyse
it (for example, taking the ratio of two signals such as <inline-formula><mml:math id="M114" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e2046">However, if only the ratio of the signals, and not their instantaneous amplitudes, is sought, it is enough that the dynamic constants are
similar. Alternatively, the true amplitudes may be obtained if the input signals have variations in timescales longer than the characteristic response times
of the sensors, and the measurement is taken for a time longer than the response time of the sensor. This can be achieved in two ways, either by
selecting carefully the characteristics of the sensors or by exposing them to a near-constant signal. To achieve the latter, a practical solution is
to take a sample of the gas and then expose the sensors to the sampled gas for a time long enough to achieve the correct amplitudes. Our system
fulfils these two criteria: the sensors have similar response characteristics, and the MultiGAS incorporates a bag and pump unit that makes it
possible to take samples of the plume and then expose it to the sensors for several minutes i.e. on the ground (see Sect. 2.5). In this mode the gas from the Teflon bag
is circulated through the detectors in a closed loop, thereby exposing the detectors for the constant gas concentration in the sample for several
minutes. Another advantage here is that any possible losses, i.e. wall effects, could be monitored and compensated for. This method was however not
tested in the actual field campaign because the limited gas samples were instead used for isotopic composition analyses.</p>
      <p id="d1e2049">A detailed analysis of the problems encountered when combining data from sensors with different response times is given in the following section.</p>
<?pagebreak page4262?><sec id="Ch1.S2.SS4.SSS1">
  <label>2.4.1</label><title>Correction of time-response differences in MultiGAS sensors</title>
      <p id="d1e2060">When measurements are made with combined data from several sensors having a different response time, e.g. measurements of the ratio <inline-formula><mml:math id="M115" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
using a MultiGAS instrument, great care must be taken.</p>
      <p id="d1e2081">In this measurement procedure, three characteristic times are important:
<list list-type="bullet"><list-item>
      <p id="d1e2086">the time of variability in gas concentration, <inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">v</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>;</p></list-item><list-item>
      <p id="d1e2101">the sampling time, <inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>;</p></list-item><list-item>
      <p id="d1e2116">the response time of the sensor, <inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (meaning the time to reach 90 % of the true signal for a step change in concentration, higher than
the detection limit).</p></list-item></list></p>
      <p id="d1e2130">The first characteristic is determined by variability in emission, variability caused by local turbulence at the point of measurement and variability
caused by relative transit of the drone with respect to the plume. The second characteristic is determined by the sampling rate of the instrument and
the time required for exchange of the gas sample inside the measurement cavity. By the third characteristic, we mean the dynamic response time of the
sensor. Because sensors often operate according to different principles, the sensor response times are usually different; this may introduce artefacts
in the mixing ratios, which would then result in wrong molar ratios for the different species, as discussed by Aiuppa et al. (2005), Shinohara (2005),
Roberts et al. (2017) and Liu et al. (2019).</p>
      <p id="d1e2133">Drone MultiGAS measurements are normally performed by hovering in a region of high gas concentration. This means that the relative motion of gas
parcels is mostly determined by local turbulence. Farther away from active vents, concentration heterogeneities are largely smoothed out, but the
signal is very weak. Therefore, strong signals are usually subject to high variability.</p>
      <?pagebreak page4263?><p id="d1e2137">Our MultiGAS intakes a flow of 0.5 <inline-formula><mml:math id="M119" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M120" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M121" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> <inline-formula><mml:math id="M122" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>), which means that for a measurement cell section of
<inline-formula><mml:math id="M123" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 10 <inline-formula><mml:math id="M124" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>, the flow speed is in the order of 0.01 <inline-formula><mml:math id="M125" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. This results in a negligible dynamic pressure in relation to
atmospheric pressure inside the measurement cavity. The relation between the sampling and variability time is determined by the Nyquist criterion. The
instrument would only be able to capture signals with frequency fluctuations lower than half the sampling frequency accurately (in practice, a much
higher sampling frequency is required). Our MultiGAS takes a sample every second, so variations with frequencies higher than 0.5 <inline-formula><mml:math id="M126" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula> cannot be
properly captured. Such dynamic changes in plume composition are assumed to be improbable for most typical scenarios. The <inline-formula><mml:math id="M127" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor has a
cavity with dimensions of 153 <inline-formula><mml:math id="M128" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M129" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 30 <inline-formula><mml:math id="M130" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M131" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 36 <inline-formula><mml:math id="M132" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula>; i.e. the sampling volume of 0.17 <inline-formula><mml:math id="M133" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi></mml:mrow></mml:math></inline-formula> is
exchanged in a time of about 20 <inline-formula><mml:math id="M134" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>. For the electrochemical sensors, the response time depends on the transport through the membrane,
dissolution in the electrolyte, reaction time and sampling. Thus, differences in sensor geometry and measurement principle produce differences in response times, even if the gas flow rate remains constant (i.e. with the same pump).</p>
      <p id="d1e2306">The response time depends on the dynamic properties of the sensor and the nature of the signal. For first-order sensors, only one energy-storing and
one energy-dissipating component dominate, and oscillatory behaviours are neglected. For such sensors, the dynamical response can be modelled through
the differential equation (e.g. Pallas-Areny and Webster, 1991):
              <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M135" display="block"><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mi>y</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:mi>y</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is the time-varying input signal (e.g. mixing ratio of <inline-formula><mml:math id="M137" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), <inline-formula><mml:math id="M138" display="inline"><mml:mrow><mml:mi>y</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is the time-varying measured signal (e.g. voltage of the
<inline-formula><mml:math id="M139" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> electrochemical sensor), <inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:mi>y</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">d</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> is the first derivative of the measured signal with respect to time, and <inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
a<inline-formula><mml:math id="M142" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:math></inline-formula> are constants identified with the response time (<inline-formula><mml:math id="M143" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M144" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and static sensitivity of the sensor (<inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:mi>K</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e2505">The dynamical time-response factor defines a delay in the response of the measured signal in relation to the input signal. If the input signal is a
step function, one usually relates this factor by the time required for the sensor to achieve a certain level of the signal, for example
90 %. Periodical signals will be affected by an error in amplitude and by a shift caused by the frequency response of the sensor. The steady-state
amplitude response to a signal of angular frequency <inline-formula><mml:math id="M147" display="inline"><mml:mi mathvariant="italic">ω</mml:mi></mml:math></inline-formula> is given by <inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>/</mml:mo><mml:mo>[</mml:mo><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mi mathvariant="italic">τ</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:mo>)</mml:mo><mml:msup><mml:mo>]</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>. The shift is given by
<inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:msup><mml:mi>tan⁡</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mi mathvariant="italic">τ</mml:mi></mml:mrow></mml:math></inline-formula>). An arbitrary signal can be represented by a Fourier sum of periodical signals, and for linear systems, the response of<?pagebreak page4264?> the
sensor is obtained by superposition of the responses to the monochromatic signals (Pallas-Areny and Webster, 1991).</p>
      <p id="d1e2567">We correct our signals based on these conditions:<list list-type="bullet"><list-item>
      <p id="d1e2572">Sensors of the MultiGAS instrument can be accurately modelled as first-order systems.</p></list-item><list-item>
      <p id="d1e2576">The input signals of different sensors measured at the same time are highly correlated.</p></list-item><list-item>
      <p id="d1e2580">Variability of the gas concentration occurs at a characteristic time much shorter than the exchange time in the sensor.</p></list-item><list-item>
      <p id="d1e2584">The total measurement time is much larger than the exchange/diffusion time in the sensor.</p></list-item></list></p>
      <p id="d1e2587">The first assumption is supported by the design and laboratory characterization of the electrochemical and optical sensors. The second assumption
requires that the molar ratio of different species is constant and homogeneous within the time of measurement. Sampling a heterogeneous mixture would
produce different ratios at different times, complicating both the measurement and the interpretation of the results. In volcanic emissions, drastic
changes in molar ratios within minutes are unlikely if the gases come from the same source. But if the plume mixes emissions from different vents, or
if large local heterogeneities affect the chemistry or condensation of different species unequally (e.g. for plumes with heterogeneous
concentration of ash), changes in gas molar ratios can occur, even on short timescales (Kelly et al., 2013). The third condition ensures that enough
information is available for finding a unique solution because the high variability in the signal is required for the cross-correlation analysis, and
the fourth condition is required to reduce the error caused by sampling over different exchange/diffusion times of the sensors.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e2593"><bold>(a)</bold> Time series of <inline-formula><mml:math id="M150" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M151" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratios measured inside the crater of Tavurvur volcano in September 2016 using a MultiGAS unit (Arellano et al., 2017). The two signals are reconstructed iteratively until an optimal correlation is found between them. For this instrument, the <inline-formula><mml:math id="M152" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor was slower than the <inline-formula><mml:math id="M153" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor and could not capture all rapid fluctuations. <bold>(b)</bold> After the correction, the correlation between the two series is higher, and the dispersion of the scatter plot much lower. But most importantly, the <inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> molar ratio changes from 2.8 <inline-formula><mml:math id="M155" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.3 to 2.6 <inline-formula><mml:math id="M156" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.08 (<inline-formula><mml:math id="M157" display="inline"><mml:mo lspace="0mm">±</mml:mo></mml:math></inline-formula> of 95 % CI), and the background <inline-formula><mml:math id="M158" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (inside the crater) changes from 457 <inline-formula><mml:math id="M159" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 26 to 473 <inline-formula><mml:math id="M160" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 9 <inline-formula><mml:math id="M161" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula>.</p></caption>
            <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f05.png"/>

          </fig>

      <p id="d1e2725">Based on the first assumption, our method starts with the two measured signals (e.g. <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:msub><mml:mi>y</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi>y</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>) and
constructs from them their derivatives (<inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:msub><mml:mi>y</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:mi mathvariant="normal">d</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:msub><mml:mi>y</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:mi mathvariant="normal">d</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula>) by simple
numerical approximation, which works fine as long as the sampling time is short (i.e. as long as large variability in timescales shorter than the
sampling rate is not expected). Based on the second assumption, we expect that a simple scaling exists between the two input signals, defining a
constant ratio <inline-formula><mml:math id="M166" display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> (<inline-formula><mml:math id="M167" display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M168" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:msub><mml:mi>x</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:msub><mml:mi>x</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>). Now we simply iteratively vary the time-response factors of the two
signals and look for the combination that maximizes the cross-correlation between the reproduced inputs according to Eq. (1) (see Appendix B for an
implementation of this method). This method works best for strongly fluctuating signals, rich in information for the correlation analysis. Figure 5
shows an example of this method applied to field measurements of a very dynamical signal obtained in the crater of Tavurvur volcano (Papua New Guinea)
in 2016 using the Sunkist instrument.</p>
      <p id="d1e2888">This method is quite general for the correction of the dynamic response of the sensors. It obviates time-consuming and frequent characterization of
the response time in a laboratory and accounts for the fact that the sensors may change their dynamic characteristics when exposed to different
conditions in the field, relative to the lab. Of course, calibration is still desirable to check for possible changes in offset and sensitivity of the
sensor over time.</p>
</sec>
</sec>
<sec id="Ch1.S2.SS5">
  <label>2.5</label><title>Bag sampling unit for gas composition and isotopic analysis</title>
      <p id="d1e2901">In some cases, real-time measurements in the gas plume are not possible, either because longer measurement time is needed to reduce the signal-to-noise
ratio or because the measurement requires an analytical technique that is more complex than can be performed in situ on a drone platform. In such
cases, acquiring a sample of the plume gas using a drone carrying a sample bag and a pump may be a viable option. For successful sampling of the most
concentrated region of the plume, real-time data transmission of a plume tracer – such as <inline-formula><mml:math id="M170" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> – to the drone operator on the ground (in
combination with manual flight control to respond accordingly) is advantageous; however, this can be technically challenging, especially for
long-range flights.</p>
      <p id="d1e2915">Measurement of the carbon isotope composition of volcanic <inline-formula><mml:math id="M171" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is a key example of an application that requires in-plume sample
collection. Carbon isotope analyses are performed using instrumentation such as isotope ratio mass (IRMS) spectrometers (Chiodini et al., 2011; Sharp,
2007), bench-top infrared spectroscopic analyses (Fischer and Lopez, 2016; Rizzo et al., 2014; van Geldern et al., 2014) or cavity ring down
spectroscopy (Lucic et al., 2015). While the bench-top spectroscopic techniques are much more portable than IRMS systems and do not require a vacuum,
they still depend on a stable 110 or 220 <inline-formula><mml:math id="M172" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula> power source and pressurized calibration and dilution gases – facilities that are not always
available in remote field locations. The spectroscopic techniques generally require a sample volume of about 300 <inline-formula><mml:math id="M173" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi></mml:mrow></mml:math></inline-formula> at atmospheric pressure
and temperature. This can be accomplished by directly placing the instrument in the volcanic plume (Rizzo et al., 2014, 2015) or by collecting a plume
or fumarole sample in an appropriately sealed and non-reactive container (i.e. Tedlar sample bags) for subsequent analyses by spectroscopy (Fischer
and Lopez, 2016). The application of drones for this purpose is advantageous over the use of helicopters due to the lower operational cost and
smaller scale logistics, as well as avoiding sample contamination by gases present in the helicopter exhaust (Fischer and Lopez, 2016).</p>
      <p id="d1e2945">During our fieldwork at Manam volcano, we used two payloads to sample the plume. In the first, we equipped our drone with four Tedlar sampling
bags. Each bag was connected to a small rotary pump triggered by a timer. The drone operator positioned the drone in the plume, at which point<?pagebreak page4265?> the
sample was collected by a timed trigger. The duration of sample collection was approximately 45 <inline-formula><mml:math id="M174" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> at an approximate flow rate of
1 <inline-formula><mml:math id="M175" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. A valve system was not necessary because the pump also functioned as a valve once it stopped pumping. The second system was
similar, but here the pump (at 0.5 <inline-formula><mml:math id="M176" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) could be remotely controlled, and only one Tedlar bag was used. After return of the samples to
the ground, the valves on the Tedlar bags were closed, and the samples were analysed by a Delta Ray infrared spectrometer. In addition to collecting samples
from the plume, a clean air sample was collected upwind and at the same elevation as the plume. In principle, the analytical procedure followed that
described in Fischer and Lopez (2016). Due to the remote location of Manam island and the difficulty encountered when obtaining calibration and
<inline-formula><mml:math id="M177" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>-free air gases in-country, we developed an air purification system that utilized a bicycle pump and <inline-formula><mml:math id="M178" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> scrubber,
Sulfolime™, obtained from PP systems Inc., to produce pressurized <inline-formula><mml:math id="M179" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>-free air. This system allowed the production of
essentially unlimited amounts of <inline-formula><mml:math id="M180" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>-free air with <inline-formula><mml:math id="M181" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> contents of <inline-formula><mml:math id="M182" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 0.7 <inline-formula><mml:math id="M183" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula>, as measured using the Delta Ray. The
calibration gas was pure <inline-formula><mml:math id="M184" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> obtained from a local distributor. Prior to analysis, the C isotope composition of this gas was not known, and
we therefore collected a sample of this gas to analyse back in the Volatiles Laboratory at the University of New Mexico using the Delta Ray and
standard calibration gases. Therefore, we were not able to determine the exact C isotope compositions of the samples in the field but were able to
adjust the pure <inline-formula><mml:math id="M185" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration gas to the concentration of <inline-formula><mml:math id="M186" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measured in the bag sample by setting the corresponding
<inline-formula><mml:math id="M187" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration in the Delta Ray software. We then retroactively corrected all our measurements using the values obtained for the field
calibration gas.</p>
</sec>
<sec id="Ch1.S2.SS6">
  <label>2.6</label><title>Plume sampling of halogens using a denuder system</title>
      <p id="d1e3114">Besides <inline-formula><mml:math id="M188" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M190" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, halogens are among the major constituents of volcanic emissions (Textor et al., 2004). The
discovery of bromine monoxide (BrO) in volcanic plumes and the correlation of the simultaneously gained <inline-formula><mml:math id="M191" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrO</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> ratio with volcanic activity
by automatized instruments (Lübcke et al., 2014) made <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrO</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> a promising volcano monitoring tool. To utilize <inline-formula><mml:math id="M193" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrO</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> ratios
for monitoring volcanic activity, an understanding of ongoing bromine chemistry in the plume is essential. For a detailed discussion on bromine
chemistry in volcanic plumes, see Gutmann et al. (2018) and references therein. Besides BrO, no other bromine species can be detected by remote-sensing
instruments. Therefore in situ methods have been developed recently for the determination of reactive bromine (BrX) and hydrogen bromide (HBr)
(Rüdiger et al., 2017; Gutmann et al., 2020, respectively). The new methods reveal the downwind conversion
of released HBr to other bromine species with time in a volcanic plume.</p>
      <p id="d1e3198">Bromine speciation can be measured using gas diffusion denuder systems. Gaseous molecules are derivatized in situ by an organic coating at the inner
walls when pumped through gas diffusion denuders. Analysis of bromine speciation has been carried out for two different bromine species. HBr has been
determined by 5,6-epoxy-[1,10]-phenanthroline-coated denuders (Gutmann et al., 2020), and BrX (such as
<inline-formula><mml:math id="M194" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">Br</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, BrCl, HOBr) and reactive chlorine species (ClX) were detected by 1,3,5-trimethoxybenzene-coated denuders (Rüdiger et al.,
2017). Samples were analysed by high-performance liquid chromatography or gas chromatography coupled to mass spectrometry, at the University of Mainz,
Germany, after returning from the field.</p>
      <p id="d1e3212">For the detection of <inline-formula><mml:math id="M195" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> a compact MultiGAS-type system called “Sunkist” (Rüdiger et al., 2018) was used, which<?pagebreak page4266?> contained an
electrochemical CiTiceL 3MST/F sensor. The calibration of the electrochemical <inline-formula><mml:math id="M196" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor followed Arellano et al. (2017). The Sunkist
also measures ambient pressure and temperature. Since the thermometer is inside the isolated box and is affected by running instruments, only
temperatures at the beginning of the flight were considered. The temperature at the starting position was 26 <inline-formula><mml:math id="M197" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> for the first flight
and 32 <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> for the second. Assuming a vertical temperature gradient of <inline-formula><mml:math id="M199" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>5 <inline-formula><mml:math id="M200" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">km</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> and an approximate flight height of
2000 <inline-formula><mml:math id="M201" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, 16 and 22 <inline-formula><mml:math id="M202" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> were estimated for calculations, respectively.</p>
      <p id="d1e3306">Denuders were connected by PTFE tubes to a micro pump providing 200 <inline-formula><mml:math id="M203" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for each denuder. Denuder sampling does not provide
time-resolved samples and instead yields an average concentration for the whole exposure interval (i.e. an average per flight). Since results obtained
with environmental denuders predict that these bromine species usually only appear within the volcanic plume, we calculate their plume concentrations
based on the known duration of exposure in the plume as detected by the <inline-formula><mml:math id="M204" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor. Figure 6 shows a photo of the drone, with denuders and
Sunkist, mounted on the drone and ready for take-off.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e3340">Drone-based denuder sampling setup and <inline-formula><mml:math id="M205" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor (Sunkist).</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f06.jpg"/>

        </fig>

      <p id="d1e3360">A blank correction for denuder results was performed by subtracting analysis results from coated denuders that travelled alongside samples but did not
sample any air.</p>
      <p id="d1e3363">Background environmental blanks were sampled at the starting position of flights. For subtraction of background environmental blanks, the atmospheric
concentration of samples (ppb) was calculated for the total flight time. After blank subtraction, the atmospheric concentration of the bromine species
was calculated for the duration in the plume (estimated based on <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> signals).</p>
      <p id="d1e3377">Limits of detection (LOD) and limits of quantification (LOQ) were calculated via 3 and 10 times deviation of the coated denuder blanks (<inline-formula><mml:math id="M207" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>),
respectively. LOD and LOQ are dependent on sampling time and the processing method in the laboratory and are, therefore, calculated for each sample
separately.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Manam field-campaign conditions</title>
      <p id="d1e3408">A field campaign was conducted at Manam volcano in Papua New Guinea during 19–27 May 2019. This field campaign utilized all above-mentioned
measurement and sampling techniques and was the culmination of several previous campaigns during which parts of the system had been extensively tested
and modified in response to lessons learnt (see Sect.  2.1.1). The meteorological conditions during the campaign at Manam were characterized by low
wind speeds and varying wind direction. Volcanic gas was emitted from two different locations close to the summit, the Main Crater and the Southern Crater (Liu et al., 2020). The Southern Crater was the most active, with incandescent lava visible within the crater and emanation of a persistent
strong gas plume with high buoyancy (2–3 <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">km</mml:mi></mml:mrow></mml:math></inline-formula> above the crater rim). In contrast, the Main Crater showed more fumarolic degassing, generating a
weaker plume with reduced buoyancy (see Fig. 7). Due to the low wind speed and varying wind direction, during some periods there was a buildup of high
ambient <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations covering a large part of the island, giving rise to challenging measurement conditions.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7" specific-use="star"><?xmltex \currentcnt{7}?><?xmltex \def\figurename{Figure}?><label>Figure 7</label><caption><p id="d1e3432"><bold>(a)</bold> Map showing the location of Manam volcano (based on GeoMapApp; Ryan et al., 2009), with the main sites of launch of our drone (red) and the location of the crater emissions (black). <bold>(b)</bold> Photo of the plumes of Manam taken on the 27 May 2019 from Site 1.</p></caption>
          <?xmltex \igopts{width=455.244094pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f07.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Plume speed measurements</title>
      <p id="d1e3454">Figure 8 shows the horizontal wind velocity measured with an anemometer on board the drone, made in connection with a MultiGAS measurement on 22 May
2019. The high wind speeds measured before reaching the maximum altitude are due to a combination of wind velocity and horizontal drone velocity when
approaching the plume region. After reaching the plume region (indicated by increased <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration around 2000 <inline-formula><mml:math id="M211" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> altitude), the
drone is kept at a fixed position, and after a short time a stable plume speed of 3.0 <inline-formula><mml:math id="M212" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.5 <inline-formula><mml:math id="M213" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> is obtained.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><?xmltex \def\figurename{Figure}?><label>Figure 8</label><caption><p id="d1e3502">Horizontal wind speed measurement made 22 May 2019 using an onboard anemometer. The effective measurement of wind speed at a certain level is obtained when the drone is placed in a hovering position for several seconds, usually in combination with composition measurements or gas sampling.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f08.png"/>

        </fig>

      <p id="d1e3511">Figure 9 shows a plume speed measurement made using the drone drift method. After reaching the plume altitude, the drone GPS is deactivated remotely,
and after a time lag (caused by the inertia of the drone), a stable drift speed of 3.8 <inline-formula><mml:math id="M214" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> is obtained.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><?xmltex \currentcnt{9}?><?xmltex \def\figurename{Figure}?><label>Figure 9</label><caption><p id="d1e3534">Example of a plume speed measurement made by the drone drift method on 27 May 2019. The sequence starts at the moment when the GPS position is unlocked, and the drone is left free to be drifted by the wind at an altitude of 1911 <inline-formula><mml:math id="M215" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula> It took about 30 <inline-formula><mml:math id="M216" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> to stabilize at 3.8 <inline-formula><mml:math id="M217" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f09.png"/>

        </fig>

      <p id="d1e3593">As can be seen in Fig. 10, the wind speed at Manam during the field campaign was variable and relatively low, 1–4 <inline-formula><mml:math id="M218" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, except on the
final day (27 May 2019). This variability results in larger overall emission rate error estimates, as a change of a few metres per second (<inline-formula><mml:math id="M219" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) in wind speed
generates a large uncertainty in the emission. However, the data from the ECMWF regional model are in relatively good agreement with our drone
measurements.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10"><?xmltex \currentcnt{10}?><?xmltex \def\figurename{Figure}?><label>Figure 10</label><caption><p id="d1e3632">Wind data at 1800 <inline-formula><mml:math id="M220" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> altitude at Manam volcano showing model data from the ECMWF ERA5 model and drone data using the drone drift and in situ anemometer methods, as well as results from a ground-based dual-beam remote-sensing method (Johansson et al., 2009). The drone measurements were taken at different altitudes (between 1500 and 2500 <inline-formula><mml:math id="M221" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula>), where a <inline-formula><mml:math id="M222" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> signal was detected by the MultiGAS sensor. All winds are horizontal wind only.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f10.png"/>

        </fig>

<?xmltex \hack{\newpage}?>
</sec>
<?pagebreak page4267?><sec id="Ch1.S3.SS3">
  <label>3.3</label><?xmltex \opttitle{{$\protect\chem{SO_{{2}}}$} emission rate}?><title><inline-formula><mml:math id="M223" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emission rate</title>
      <p id="d1e3706">Figure 11 shows an example of a MobileDOAS traverse made at an altitude of 1000 <inline-formula><mml:math id="M224" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula> at Manam volcano on 27 May 2019. An <inline-formula><mml:math id="M225" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
emission rate of 5200 <inline-formula><mml:math id="M226" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 660/180 <inline-formula><mml:math id="M227" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">t</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">d</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> was obtained for this traverse using a wind speed at plume height of 6 <inline-formula><mml:math id="M228" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>
measured with the drone drift method about 30 min after completing the traverse.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11"><?xmltex \currentcnt{11}?><?xmltex \def\figurename{Figure}?><label>Figure 11</label><caption><p id="d1e3788">Example of MobileDOAS traverse made at Manam volcano on 27 May 2019 at an altitude of 1000 <inline-formula><mml:math id="M229" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula> The emission rate of <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was 5200 <inline-formula><mml:math id="M231" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 660/180 <inline-formula><mml:math id="M232" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">t</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">d</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, using the plume speed shown in Fig. 9. Information about the position of the drone below the plume is telemetered in real time.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f11.png"/>

        </fig>

      <p id="d1e3857">This drone-based emission rate measurement can be compared to ScanDOAS measurements made from the ground on the same day, yielding an average over the
day of 4512 <inline-formula><mml:math id="M233" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2230 <inline-formula><mml:math id="M234" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">t</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">d</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, using wind speed from the ECMWF ERA5 model (Liu et al., 2020). One possible reason for this higher value
in the drone measurement is that the relatively high elevation minimizes the atmospheric scattering dilution in this measurement. Over the
full period of the field campaign, the representative <inline-formula><mml:math id="M235" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux was estimated at 5150 <inline-formula><mml:math id="M236" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> [733/336] <inline-formula><mml:math id="M237" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">t</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">d</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (high and low
1<inline-formula><mml:math id="M238" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> bound on uncertainty) by synthesizing a large number of measurements (and their respective uncertainties) from ground-based, drone-mounted
and satellite-based approaches (Liu et al., 2020).</p>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Molar ratios</title>
      <p id="d1e3935">Figure 12 shows the results from a flight simultaneously carrying a MultiGAS instrument and a plume sampling device on the drone. To obtain the
<inline-formula><mml:math id="M239" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> ratio, it was first<?pagebreak page4268?> necessary to compensate for (a) the pressure and temperature effects on the raw concentration data, (b) the
dynamical responses of the sensors and (c) the atmospheric background concentration of <inline-formula><mml:math id="M240" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (see details in Appendix B), where the
background is identified as the concentration of <inline-formula><mml:math id="M241" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> taken at the same altitude outside of the plume (where the plume tracer
<inline-formula><mml:math id="M242" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M243" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 0). The resulting <inline-formula><mml:math id="M244" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> ratios are shown in Fig. 13. Using a linear regression, a <inline-formula><mml:math id="M245" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> ratio of
0.9 <inline-formula><mml:math id="M246" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.2 is obtained for the Manam plume on 26 May 2019. For the entire campaign in 2019, the average plume molar ratio was 1.07 <inline-formula><mml:math id="M247" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.06
based on multiple measurements acquired on different days; these additional measurements were obtained using a different (but essentially similar in
operation) MultiGAS unit on board a fixed-wing unmanned aerial vehicle (UAV). The full dataset and volcanological discussion thereof are presented in Liu et al. (2020).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12"><?xmltex \currentcnt{12}?><?xmltex \def\figurename{Figure}?><label>Figure 12</label><caption><p id="d1e4049">MultiGAS measurements of <inline-formula><mml:math id="M248" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M249" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratios at 500 <inline-formula><mml:math id="M250" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> above the Southern Crater of Manam volcano on 26 May 2019. <inline-formula><mml:math id="M251" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was detected in small concentrations above the Main Crater (region around 800–900 <inline-formula><mml:math id="M252" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> after launch) but peaked above the high emission column of the Southern Crater. <inline-formula><mml:math id="M253" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations above background values are only detected over this crater. The shaded area corresponds to periods of bag sampling activated remotely and used for isotopic analysis at Baliau village by the Delta Ray infrared mass spectrometer.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f12.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F13"><?xmltex \currentcnt{13}?><?xmltex \def\figurename{Figure}?><label>Figure 13</label><caption><p id="d1e4121">A regression plot of data from Fig. 12 yielding a <inline-formula><mml:math id="M254" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> ratio of 0.9 <inline-formula><mml:math id="M255" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.2. Only corresponding pairs where the <inline-formula><mml:math id="M256" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratio was higher than 2 <inline-formula><mml:math id="M257" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> and the altitude was stable (<inline-formula><mml:math id="M258" display="inline"><mml:mo lspace="0mm">&gt;</mml:mo></mml:math></inline-formula> 2140 <inline-formula><mml:math id="M259" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">a</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">m</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">s</mml:mi><mml:mo>.</mml:mo><mml:mi mathvariant="normal">l</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></inline-formula>) were used for the regression.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f13.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS5">
  <label>3.5</label><title>Carbon isotopic composition</title>
      <p id="d1e4216">Figure 12​​​​​​​ shows data from a flight conducted on 26 May 2019 combining a MultiGAS instrument with a bag sampling unit. A first bag sample was collected
after reaching the anticipated plume location, although no significant <inline-formula><mml:math id="M260" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration was seen in the real-time data on the ground. After
some manoeuvering of the drone, the plume was found, and a second bag sample was collected.</p>
      <?pagebreak page4269?><p id="d1e4230"><?xmltex \hack{\newpage}?>Most samples obtained from Manam had concentrations similar to the clean air background, with <inline-formula><mml:math id="M261" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations ranging from 408 to
415 <inline-formula><mml:math id="M262" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M263" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. These samples had variable and unreliable <inline-formula><mml:math id="M264" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> values ranging from <inline-formula><mml:math id="M265" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>4.2 ‰ to <inline-formula><mml:math id="M266" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>8.6 ‰,
reflecting the large error on these low concentration samples. Only five samples were obtained with concentrations above 420 <inline-formula><mml:math id="M267" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula>, ranging from
421 to 494 <inline-formula><mml:math id="M268" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M269" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>; these data and the volcanological interpretation thereof are discussed in Liu et al. (2020). Extrapolation of
these data to 100 % <inline-formula><mml:math id="M270" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> following the methodology of Fischer and Lopez (2016) and Rizzo et al. (2014) yields a value of
<inline-formula><mml:math id="M271" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M272" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M273" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.7 ‰, close to the MOR (mid-oceanic ridge) mantle range of <inline-formula><mml:math id="M274" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>5 <inline-formula><mml:math id="M275" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 1 ‰ of Marty and Zimmermann (1999) and
<inline-formula><mml:math id="M276" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>6.5 <inline-formula><mml:math id="M277" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2 ‰ of Sano and Marty (1995). We note, however, that the regression is unconstrained at high <inline-formula><mml:math id="M278" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> due to the low
<inline-formula><mml:math id="M279" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations of the plume samples; therefore, statistically the potential extrapolated range could be as large as
<inline-formula><mml:math id="M280" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.7 <inline-formula><mml:math id="M281" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 9.5 ‰ in the 95 % confidence interval, i.e. a very large uncertainty (Liu et al., 2020). Values above <inline-formula><mml:math id="M282" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>1 ‰ are
highly unlikely, given that the global compilation of arc gases has a <inline-formula><mml:math id="M283" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> range of <inline-formula><mml:math id="M284" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>2 ‰ to <inline-formula><mml:math id="M285" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>19 ‰ (Fischer and
Chiodini, 2015; Mason et al., 2017). The lowest possible value within that range of uncertainty would be
<inline-formula><mml:math id="M286" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>13.2 ‰. We can, therefore, rule out a significant contribution from organic carbon, which would have <inline-formula><mml:math id="M287" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> values of
around <inline-formula><mml:math id="M288" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>30 ‰ (Sano and Marty, 1995). Our data are generally consistent with <inline-formula><mml:math id="M289" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> values of fumarole and hot spring gases
obtained during the few prior studies in the PNG region (<inline-formula><mml:math id="M290" display="inline"><mml:mo lspace="0mm">-</mml:mo></mml:math></inline-formula>2.7 <inline-formula><mml:math id="M291" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.1 ‰, Sano and Williams, 1996). Additional data from more
concentrated samples (with higher <inline-formula><mml:math id="M292" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations ideally <inline-formula><mml:math id="M293" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 1000 <inline-formula><mml:math id="M294" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula>) collected closer to the vent would improve the accuracy
of the Manam <inline-formula><mml:math id="M295" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> values. Nevertheless, most importantly these results demonstrate a valuable proof-of-concept that highlights the
potential of drone-based sampling of volcanic emissions for future geochemical studies.</p><?xmltex \hack{\newpage}?>
</sec>
<sec id="Ch1.S3.SS6">
  <label>3.6</label><title>Halogen concentrations</title>
      <p id="d1e4573">On 27 May 2019, we achieved two successful flights with the denuder system where detection of <inline-formula><mml:math id="M296" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> indicated that we had entered the
plume. In both flights we detected <inline-formula><mml:math id="M297" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in two positions, each at different altitudes, consistent with the observation of two source regions
for summit emissions (Fig. 14). The maximum <inline-formula><mml:math id="M298" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations were 1.74 and 1.87 <inline-formula><mml:math id="M299" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> in flight 1 and 1.22 and 4.62 <inline-formula><mml:math id="M300" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> in
flight 2 for peak 1 and 2, respectively. Detected <inline-formula><mml:math id="M301" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations were averaged for each time we entered the plume. <inline-formula><mml:math id="M302" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
concentration for each flight was averaged proportionally to the sampling duration in the plume (Table 2).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F14" specific-use="star"><?xmltex \currentcnt{14}?><?xmltex \def\figurename{Figure}?><label>Figure 14</label><caption><p id="d1e4650"><inline-formula><mml:math id="M303" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> data detected by Sunkist in two flights on 27 May 2019.</p></caption>
          <?xmltex \igopts{width=483.69685pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f14.png"/>

        </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e4672">Bromine speciation based on the length of stay in the plume detected by the <inline-formula><mml:math id="M304" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> sensor.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.99}[.99]?><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Date</oasis:entry>
         <oasis:entry colname="col2">27 May 2019</oasis:entry>
         <oasis:entry colname="col3">Flight 1</oasis:entry>
         <oasis:entry colname="col4">Flight 2</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Start time</oasis:entry>
         <oasis:entry colname="col2">[local]</oasis:entry>
         <oasis:entry colname="col3">06:54</oasis:entry>
         <oasis:entry colname="col4">11:11</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Average <inline-formula><mml:math id="M305" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>/both peaks</oasis:entry>
         <oasis:entry colname="col2">[ppm]</oasis:entry>
         <oasis:entry colname="col3">0.6</oasis:entry>
         <oasis:entry colname="col4">1.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M306" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HBr</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M307" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M308" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">30</oasis:entry>
         <oasis:entry colname="col4">44</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M309" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M310" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HBr</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M311" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M312" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">13</oasis:entry>
         <oasis:entry colname="col4">9</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M313" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M314" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M315" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">3</oasis:entry>
         <oasis:entry colname="col4">5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M316" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M317" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M318" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M319" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">3</oasis:entry>
         <oasis:entry colname="col4">3</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M320" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">HBr</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M321" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 100</oasis:entry>
         <oasis:entry colname="col3">10</oasis:entry>
         <oasis:entry colname="col4">12</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M322" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M323" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">HBr</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M324" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 100</oasis:entry>
         <oasis:entry colname="col3">12</oasis:entry>
         <oasis:entry colname="col4">6</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M325" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HBr</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">1.7</oasis:entry>
         <oasis:entry colname="col4">4.6</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M326" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M327" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HBr</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.7</oasis:entry>
         <oasis:entry colname="col4">0.9</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">LOD</oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">4.3</oasis:entry>
         <oasis:entry colname="col4">3.5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">LOQ</oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">14.3</oasis:entry>
         <oasis:entry colname="col4">11.7</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M328" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.2</oasis:entry>
         <oasis:entry colname="col4">0.5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M329" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M330" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.2</oasis:entry>
         <oasis:entry colname="col4">0.3</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">LOD</oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.2</oasis:entry>
         <oasis:entry colname="col4">0.2</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">LOQ</oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.6</oasis:entry>
         <oasis:entry colname="col4">0.6</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M331" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">ClX</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.1</oasis:entry>
         <oasis:entry colname="col4">0.3</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M332" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M333" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">ClX</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.2</oasis:entry>
         <oasis:entry colname="col4">0.2</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">LOD</oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">0.5</oasis:entry>
         <oasis:entry colname="col4">0.5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">LOQ</oasis:entry>
         <oasis:entry colname="col2">[ppb]</oasis:entry>
         <oasis:entry colname="col3">1.8</oasis:entry>
         <oasis:entry colname="col4">1.8</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

      <p id="d1e5266">For both denuder types, an environmental blank was sampled at the starting position on the ground. For HBr the denuder results were within the
deviation of unsampled but coated denuders. For reactive bromine, the environmental blank values were the highest values of the whole campaign (BrX:
0.2 <inline-formula><mml:math id="M334" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> for 3 <inline-formula><mml:math id="M335" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi></mml:mrow></mml:math></inline-formula> sampling volume). In addition, the amount of reactive chlorine was higher than that of reactive bromine in this sample
only (ClX: 0.4 <inline-formula><mml:math id="M336" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> for 3 <inline-formula><mml:math id="M337" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi></mml:mrow></mml:math></inline-formula> sampling volume). Therefore, we infer that this sample was either contaminated or the location in the grass
close to the sea does not represent the atmospheric conditions encountered during the flight. Alternatively, we subtracted an environmental blank
sampled 10 <inline-formula><mml:math id="M338" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">d</mml:mi></mml:mrow></mml:math></inline-formula> earlier in a pre-campaign at Tavurvur volcano, at an altitude of 104 <inline-formula><mml:math id="M339" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> upwind on the flank of the volcano and above
barren volcanic rock (17 May 2019, BrX: 0.002 <inline-formula><mml:math id="M340" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula>, ClX: 0.000 <inline-formula><mml:math id="M341" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula>). The result of the environmental blank of<?pagebreak page4270?> HBr was within the
deviation of coated denuders not used for sample collection.</p>
      <p id="d1e5334">Average concentrations of all analysed bromine and chlorine species based on the duration of exposure in the plume and their calculated LOD and LOQ
are given in Table 2. Results were just below the LOD for both bromine species in flight 1. Bromine results for flight 2 were below the LOQ but above
LOD. ClX was below LOD in both samples. The ratio of the bromine species to <inline-formula><mml:math id="M342" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> varies between the two flights from 30 <inline-formula><mml:math id="M343" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M344" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>
to 44 <inline-formula><mml:math id="M345" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M346" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula> for <inline-formula><mml:math id="M347" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HBr</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and 3 <inline-formula><mml:math id="M348" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M349" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula> to 5 <inline-formula><mml:math id="M350" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M351" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula> for <inline-formula><mml:math id="M352" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> from flight 1 to 2,
respectively, while the ratio between the two bromine species <inline-formula><mml:math id="M353" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">HBr</mml:mi></mml:mrow></mml:math></inline-formula> stays stable (flight 1: 0.10, flight 2: 0.12).</p>
      <p id="d1e5456">Although measurement results were below the LOQ, we were able to detect HBr and BrX in the plume of Manam volcano with our two flights. The observed
<inline-formula><mml:math id="M354" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">HBr</mml:mi></mml:mrow></mml:math></inline-formula> ratio of 0.10–0.12 is relatively low compared to previous detected ratios of approximately 0.30 within the first minute in Masaya's
plume (Rüdiger et al., 2021). Observed bromine evolution in Manam plume seems to follow the trend for high
<inline-formula><mml:math id="M355" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">Br</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula> ratios suggested by Roberts et al. (2014).</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e5492">We present a hexa-copter UAV specially configured for long-range, high-altitude volcanic gas plume measurements, together with a suite of
drone-mountable payloads specialized for various gas measurements. We describe how the drone and its payloads were operated during a field campaign at
Manam volcano in Papua New Guinea, demonstrating the utility of the proposed system for achieving long-range high-altitude volcanic gas monitoring.</p>
      <p id="d1e5495">In response to several key lessons learnt during prior field-based testing, we implemented specific customizations to the drone platform:</p>
      <p id="d1e5498"><?xmltex \hack{\newpage}?><list list-type="bullet">
          <list-item>

      <p id="d1e5504">use of stronger motors and propellers with a larger diameter to increase payload and battery weight capacity and thereby improve range and
height performance;</p>
          </list-item>
          <list-item>

      <p id="d1e5510">change of operative system to overcome altitude and range restrictions and enable access to flight logs for posterior analysis;</p>
          </list-item>
          <list-item>

      <p id="d1e5516">use of a race drone ESC (electronic speed control) to improve manoeuvrability during flight;</p>
          </list-item>
          <list-item>

      <p id="d1e5522">change in frame design to facilitate swapping of modular payloads.</p>
          </list-item>
        </list></p>
      <p id="d1e5527">The different payloads include the following:
<list list-type="bullet"><list-item>
      <p id="d1e5532">an anemometer for measurement of wind/plume speed at plume height</p></list-item><list-item>
      <p id="d1e5536">a MobileDOAS instrument that, combined with plume speed data, can measure total <inline-formula><mml:math id="M356" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emission rate by traversing below the plume;</p></list-item><list-item>
      <p id="d1e5551">a MultiGAS instrument that can measure in situ concentrations of <inline-formula><mml:math id="M357" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M358" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M359" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula> in the plume, by flying close to
the crater;</p></list-item><list-item>
      <p id="d1e5590">a bag sampling unit by which the gas in the plume can be sampled in Tedlar bags for subsequent analysis of carbon isotopes on the ground;</p></list-item><list-item>
      <p id="d1e5594">a denuder system that can sample the plume for later analysis of different halogens in the laboratory.</p></list-item></list></p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F15" specific-use="star"><?xmltex \currentcnt{15}?><?xmltex \def\figurename{Figure}?><label>Figure 15</label><caption><p id="d1e5600">Map with flight trajectories of measurements reported in this study. Wind measurement flights occurred from launch Sites 2 and 1 on 22 and 27 May, respectively. Isotopic sampling and MultiGAS flights launched from Site 3 on 26 May. MobileDOAS and Sunkist measurement flights launched from Site 1 on 27 May. Sentinel imagery shown was selected based on minimal cloud cover and may not represent the location of vents and plumes present in May 2019. The thickness of the trajectory markers is proportional to the altitude of the drone.</p></caption>
        <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/4255/2021/amt-14-4255-2021-f15.png"/>

      </fig>

      <p id="d1e5609">During the 1-week field campaign at Manam volcano, we used all these instrument payloads to perform a total of 19 successful flights to the plume of
Manam (one for <inline-formula><mml:math id="M360" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux, four for <inline-formula><mml:math id="M361" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> molar ratio, nine for wind speed, three for C isotopic analysis and two for halogen
composition). All these measurements could be carried out with only<?pagebreak page4271?> two people (one flying the drone and one supervising the measurements). Figure 15
shows the trajectories of all flights for which data are presented here.</p>
      <p id="d1e5641">The results presented here represent a subset of the total dataset obtained during a collaborative international field campaign at Manam volcano,
involving multiple research teams and instruments. A complete synthesis of all measured data and their uncertainties, together with detailed
volcanological interpretation, is presented in Liu et al. (2020). The fluxes of <inline-formula><mml:math id="M362" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M363" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> were found to be 5200 <inline-formula><mml:math id="M364" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 660/180
and 3220 <inline-formula><mml:math id="M365" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 500/90 <inline-formula><mml:math id="M366" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">t</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">d</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, respectively, based solely on the multi-rotor measurements reported in this study. The
<inline-formula><mml:math id="M367" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M368" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.7 <inline-formula><mml:math id="M369" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 9.5 ‰ suggests that the <inline-formula><mml:math id="M370" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> source of Manam crater gas is mantle-dominated with a possible
carbonate contribution and a likely insignificant contribution from subducted sedimentary organic carbon. While the range of possible values is large
due to the low <inline-formula><mml:math id="M371" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentrations and hence large extrapolation to pure <inline-formula><mml:math id="M372" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, these data are generally consistent with a measured
plume <inline-formula><mml:math id="M373" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">C</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula> ratio of 0.9 <inline-formula><mml:math id="M374" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.2, indicating a predominantly mantle-derived carbon source. The bromine speciation and concentration in the
plume point to a high <inline-formula><mml:math id="M375" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">Br</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula> ratio.</p>
      <p id="d1e5792">It was found that an adaptive flight path is essential for successful measurements, through either full manual control at long distances or adaptable
automated waypoint missions. Access to real-time data of a plume tracer, such as <inline-formula><mml:math id="M376" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, is crucial, both when flying visual and when flying
beyond visual line of sight, in order for the pilot to refine the position of the drone within the plume. Further, prior information about the
approximate position of the plume from ground-based instruments, such as ScanDOAS, is very informative during the flight planning stage to maximize
the chance of successful sampling and should be incorporated into field workflows. Finally, to facilitate at long range and high altitude, under limited
power capacity, the flight path in approaching and returning from the target is crucial to conserve battery; flying in clouds should be avoided, wind
speed and direction should be taken into account and used to their advantage and the angle between horizontal and vertical motion should be optimized
for low power consumption.</p>
      <p id="d1e5806">We have demonstrated that the combination of a multi-rotor with modular payloads is a versatile solution to obtain the flux and composition of
volcanic plumes, even for the case of a highly active volcano with a high-altitude plume such as Manam. We propose that drone-based measurements offer
a valuable solution for volcano research and monitoring applications at inaccessible volcanoes globally.</p><?xmltex \hack{\clearpage}?>
</sec>

      
      </body>
    <back><app-group>

<?pagebreak page4272?><app id="App1.Ch1.S1">
  <?xmltex \currentcnt{A}?><label>Appendix A</label><title>Technical specifications of the payloads</title>

<?xmltex \floatpos{h!}?><table-wrap id="App1.Ch1.S1.T3"><?xmltex \hack{\hsize\textwidth}?><?xmltex \currentcnt{A1}?><label>Table A1</label><caption><p id="d1e5826">Specifications of payloads of the drone system.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.74}[.74]?><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="justify" colwidth="33mm"/>
     <oasis:colspec colnum="2" colname="col2" align="justify" colwidth="30mm"/>
     <oasis:colspec colnum="3" colname="col3" align="justify" colwidth="65mm"/>
     <oasis:colspec colnum="4" colname="col4" align="justify" colwidth="34mm"/>
     <oasis:colspec colnum="5" colname="col5" align="justify" colwidth="40mm"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">MobileDOAS</oasis:entry>
         <oasis:entry colname="col3">MultiGAS <inline-formula><mml:math id="M383" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> anemometer</oasis:entry>
         <oasis:entry colname="col4">Bag sampling unit</oasis:entry>
         <oasis:entry colname="col5">Denuders <inline-formula><mml:math id="M384" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> Sunkist</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Measurement mode</oasis:entry>
         <oasis:entry colname="col2">Up-looking, traverse<?xmltex \hack{\hfill\break}?>remote sensing</oasis:entry>
         <oasis:entry colname="col3">In situ sensing</oasis:entry>
         <oasis:entry colname="col4">In situ sampling</oasis:entry>
         <oasis:entry colname="col5">In situ sampling</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Main purpose</oasis:entry>
         <oasis:entry colname="col2">Flux of <inline-formula><mml:math id="M385" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Molar ratio of <inline-formula><mml:math id="M386" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M387" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>/<inline-formula><mml:math id="M388" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula><?xmltex \hack{\hfill\break}?>Gas sampling (for post-analysis)<?xmltex \hack{\hfill\break}?>Wind velocity</oasis:entry>
         <oasis:entry colname="col4">Collect samples for posterior analysis of isotopic and gas composition</oasis:entry>
         <oasis:entry colname="col5">Gas sampling (for post-analysis of molar ratio of <inline-formula><mml:math id="M389" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HBr</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M390" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrX</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Measured quantities</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M391" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column density<?xmltex \hack{\hfill\break}?>distribution<?xmltex \hack{\hfill\break}?>Plume speed</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M392" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratio<?xmltex \hack{\hfill\break}?> <inline-formula><mml:math id="M393" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula> mixing ratio<?xmltex \hack{\hfill\break}?> <inline-formula><mml:math id="M394" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration<?xmltex \hack{\hfill\break}?>Relative humidity<?xmltex \hack{\hfill\break}?>Temperature<?xmltex \hack{\hfill\break}?>Pressure<?xmltex \hack{\hfill\break}?>Air velocity<?xmltex \hack{\hfill\break}?>Br compounds<?xmltex \hack{\hfill\break}?> <inline-formula><mml:math id="M395" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M396" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M397" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratio<?xmltex \hack{\hfill\break}?>HBr mixing ratio<?xmltex \hack{\hfill\break}?>BrX mixing ratio<?xmltex \hack{\hfill\break}?>Pressure</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Size (<inline-formula><mml:math id="M398" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M399" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M400" display="inline"><mml:mi>W</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M401" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M402" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>) (cm)</oasis:entry>
         <oasis:entry colname="col2">22 <inline-formula><mml:math id="M403" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 15 <inline-formula><mml:math id="M404" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 9</oasis:entry>
         <oasis:entry colname="col3">21 <inline-formula><mml:math id="M405" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 14 <inline-formula><mml:math id="M406" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 14</oasis:entry>
         <oasis:entry colname="col4">Inside MultiGAS</oasis:entry>
         <oasis:entry colname="col5">Sunkist 14 <inline-formula><mml:math id="M407" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 13 <inline-formula><mml:math id="M408" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 14<?xmltex \hack{\hfill\break}?>Denuders 50 <inline-formula><mml:math id="M409" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 3 <inline-formula><mml:math id="M410" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 3 <inline-formula><mml:math id="M411" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> micropump</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Weight (kg)</oasis:entry>
         <oasis:entry colname="col2">0.8</oasis:entry>
         <oasis:entry colname="col3">1</oasis:entry>
         <oasis:entry colname="col4">Inside MultiGAS</oasis:entry>
         <oasis:entry colname="col5">Sunkist 0.5<?xmltex \hack{\hfill\break}?>Denuders 0.15</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Power and voltage (W, V)</oasis:entry>
         <oasis:entry colname="col2">12, 5 V</oasis:entry>
         <oasis:entry colname="col3">4, 12 V</oasis:entry>
         <oasis:entry colname="col4">Inside MultiGAS</oasis:entry>
         <oasis:entry colname="col5">Sunkist: 9V for sensor, 3.7 LiPo for Arduino<?xmltex \hack{\hfill\break}?>9 V for micropump</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Radio link</oasis:entry>
         <oasis:entry colname="col2">433 MHz</oasis:entry>
         <oasis:entry colname="col3">433 MHz</oasis:entry>
         <oasis:entry colname="col4">433 MHz</oasis:entry>
         <oasis:entry colname="col5">NA</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Components</oasis:entry>
         <oasis:entry colname="col2">Micro-computer (Azulle Quantum<?xmltex \hack{\hfill\break}?>Access Mini PC Stick)<?xmltex \hack{\hfill\break}?>UV grating spectrometer (OceanOptics<?xmltex \hack{\hfill\break}?>Flame)<?xmltex \hack{\hfill\break}?>Telescope (25 <inline-formula><mml:math id="M412" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> diameter, FOV 11 <inline-formula><mml:math id="M413" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mrad</mml:mi></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Quartz optics (window, prism, fiber)<?xmltex \hack{\hfill\break}?>GPS antenna (GlobalSat BU353S4)</oasis:entry>
         <oasis:entry colname="col3">Micro-computer (Arduino Mega2560 with additional ADC of 16 <inline-formula><mml:math id="M414" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">bits</mml:mi></mml:mrow></mml:math></inline-formula> ADS1115)<?xmltex \hack{\hfill\break}?>Electrochemical sensors (Alphasense <inline-formula><mml:math id="M415" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>-A, response time <inline-formula><mml:math id="M416" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> 20 <inline-formula><mml:math id="M417" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>, Alphasense <inline-formula><mml:math id="M418" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>-A, response time <inline-formula><mml:math id="M419" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> 20 <inline-formula><mml:math id="M420" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Dual-band IR radiometer (SmartGas FlowEVO F3-212205-05000 <inline-formula><mml:math id="M421" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, response time <inline-formula><mml:math id="M422" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> 30 <inline-formula><mml:math id="M423" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Environmental sensor (Bosch BME280, RH, <inline-formula><mml:math id="M424" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M425" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>GPS antenna (Adafruit Ultimate)<?xmltex \hack{\hfill\break}?>Anemometer, FT Technologies Ltd (FT205EV)<?xmltex \hack{\hfill\break}?>Pump (0.5 <inline-formula><mml:math id="M426" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Tedlar bags (1 <inline-formula><mml:math id="M427" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col4">Micro-computer (Arduino)<?xmltex \hack{\hfill\break}?>Pump (1 <inline-formula><mml:math id="M428" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Four Tedlar bags (1 <inline-formula><mml:math id="M429" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col5">Micro-computer (Arduino with micro SD card logger)<?xmltex \hack{\hfill\break}?>Electrochemical sensors<?xmltex \hack{\hfill\break}?>(CiTiceL 3MST/F, response time <inline-formula><mml:math id="M430" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 20 <inline-formula><mml:math id="M431" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M432" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Environmental sensor<?xmltex \hack{\hfill\break}?>(BMP180 by Bosch<?xmltex \hack{\hfill\break}?>Sensortec)<?xmltex \hack{\hfill\break}?>Pump (200 <inline-formula><mml:math id="M433" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mL</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>/denuder)<?xmltex \hack{\hfill\break}?>Denuders (brown borosilicate glass tubes, 50 <inline-formula><mml:math id="M434" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula>, i.d. 0.7 <inline-formula><mml:math id="M435" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Sampling frequency (Hz)</oasis:entry>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry colname="col3">1</oasis:entry>
         <oasis:entry colname="col4">On/off set by timer</oasis:entry>
         <oasis:entry colname="col5">2 (<inline-formula><mml:math id="M436" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Denuders: no time resolution, one sample/flight</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Precision</oasis:entry>
         <oasis:entry colname="col2">5 <inline-formula><mml:math id="M437" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppmm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M438" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<inline-formula><mml:math id="M439" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">2 <inline-formula><mml:math id="M440" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M441" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>1 <inline-formula><mml:math id="M442" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M443" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<inline-formula><mml:math id="M444" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula><?xmltex \hack{\hfill\break}?>2 <inline-formula><mml:math id="M445" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M446" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>3 % (RH)<?xmltex \hack{\hfill\break}?>0.01 <inline-formula><mml:math id="M447" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula> (temperature)<?xmltex \hack{\hfill\break}?>0.2 <inline-formula><mml:math id="M448" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Pa</mml:mi></mml:mrow></mml:math></inline-formula> (pressure)<?xmltex \hack{\hfill\break}?>0.1 <inline-formula><mml:math id="M449" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (wind speed)<?xmltex \hack{\hfill\break}?>1<inline-formula><mml:math id="M450" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> (wind direction)</oasis:entry>
         <oasis:entry colname="col4">0.15 ‰ (<inline-formula><mml:math id="M451" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula>, analysed by Delta Ray IR spectrometer)</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Accuracy</oasis:entry>
         <oasis:entry colname="col2">10 <inline-formula><mml:math id="M452" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppmm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M453" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<inline-formula><mml:math id="M454" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">15 <inline-formula><mml:math id="M455" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M456" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>1 <inline-formula><mml:math id="M457" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M458" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<inline-formula><mml:math id="M459" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula><?xmltex \hack{\hfill\break}?>5 <inline-formula><mml:math id="M460" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppb</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M461" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>3 % (RH)<?xmltex \hack{\hfill\break}?>1 <inline-formula><mml:math id="M462" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula> (temperature)<?xmltex \hack{\hfill\break}?>120 <inline-formula><mml:math id="M463" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Pa</mml:mi></mml:mrow></mml:math></inline-formula> (pressure)<?xmltex \hack{\hfill\break}?>0.3 <inline-formula><mml:math id="M464" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (wind speed)<?xmltex \hack{\hfill\break}?>4<inline-formula><mml:math id="M465" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> (wind direction)</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M466" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.5 ‰ (<inline-formula><mml:math id="M467" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M468" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 1 <inline-formula><mml:math id="M469" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M470" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 1 % signal (<inline-formula><mml:math id="M471" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Halogen species: for each sample separately (see Table 2).</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Range</oasis:entry>
         <oasis:entry colname="col2">0–20 000 <inline-formula><mml:math id="M472" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppmm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M473" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3">0–50 <inline-formula><mml:math id="M474" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M475" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>0–1000 <inline-formula><mml:math id="M476" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M477" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>0–50 <inline-formula><mml:math id="M478" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M479" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>0 %–100 % (RH)<?xmltex \hack{\hfill\break}?>243–358 <inline-formula><mml:math id="M480" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula> (temperature)<?xmltex \hack{\hfill\break}?>300–1100 <inline-formula><mml:math id="M481" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">hPa</mml:mi></mml:mrow></mml:math></inline-formula> (pressure)<?xmltex \hack{\hfill\break}?>0–75 <inline-formula><mml:math id="M482" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (wind speed)<?xmltex \hack{\hfill\break}?>0–360<inline-formula><mml:math id="M483" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> (wind direction)</oasis:entry>
         <oasis:entry colname="col4">200 <inline-formula><mml:math id="M484" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> – 2500 <inline-formula><mml:math id="M485" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M486" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">0–200 <inline-formula><mml:math id="M487" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M488" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)<?xmltex \hack{\hfill\break}?>Halogen species: LOD and<?xmltex \hack{\hfill\break}?>LOQ for each sample<?xmltex \hack{\hfill\break}?>separately (see Table 2).</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table><table-wrap-foot><p id="d1e5829"><?xmltex \hack{\hspace{0.7cm}}?><inline-formula><mml:math id="M377" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula> For <inline-formula><mml:math id="M378" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">S</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M379" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M380" display="inline"><mml:mrow><mml:mn mathvariant="normal">500</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> assuming 50 % of intensity saturation for an average of 15 spectra taken at 0.5 <inline-formula><mml:math id="M381" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> exposure time. <inline-formula><mml:math id="M382" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula> In lab conditions. In field conditions, accuracy<?xmltex \hack{\\}?><?xmltex \hack{\hspace{0.7cm}}?> and precision may be considerably disturbed by electric interference. See Figs. S1 and S2 in the Supplement. NA: not available.</p></table-wrap-foot></table-wrap>

<?xmltex \hack{\clearpage}?>
</app>

<?pagebreak page4273?><app id="App1.Ch1.S2">
  <?xmltex \currentcnt{B}?><label>Appendix B</label><title>Analysis of MultiGAS data</title>
      <p id="d1e7337">To obtain molar ratios of different species measured by different sensors, the general procedure followed Eq. (B1):
          <disp-formula id="App1.Ch1.S2.E2" content-type="numbered"><label>B1</label><mml:math id="M489" display="block"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi>A</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">α</mml:mi><mml:mi>A</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">β</mml:mi><mml:mi>A</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mi>A</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi>A</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">π</mml:mi><mml:mi>A</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
        where <inline-formula><mml:math id="M490" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mi>A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the molar mixing ratio of molecule <inline-formula><mml:math id="M491" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula> (<inline-formula><mml:math id="M492" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M493" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M494" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula>); <inline-formula><mml:math id="M495" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">α</mml:mi><mml:mi>A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the offset of sensor for molecule <inline-formula><mml:math id="M496" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula>, from lab calibration (in ppm); <inline-formula><mml:math id="M497" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">β</mml:mi><mml:mi>A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the sensitivity of sensor for molecule <inline-formula><mml:math id="M498" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula>, from lab calibration (in <inline-formula><mml:math id="M499" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula> per count); <inline-formula><mml:math id="M500" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the signal (in counts) measured by the sensor for molecule <inline-formula><mml:math id="M501" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula>; <inline-formula><mml:math id="M502" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi>A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the temperature correction factor of sensor for molecule <inline-formula><mml:math id="M503" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula>, from manufacturer's specifications (in K); <inline-formula><mml:math id="M504" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mtext>m,c</mml:mtext></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, the temperature measured/calibrated by a thermometer in parallel to the sensor for molecule <inline-formula><mml:math id="M505" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula> (in K); <inline-formula><mml:math id="M506" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">π</mml:mi><mml:mi>A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the pressure correction factor of the sensor for molecule <inline-formula><mml:math id="M507" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula>, from manufacturer's specifications (in <inline-formula><mml:math id="M508" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">K</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>); and <inline-formula><mml:math id="M509" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mtext>m,c</mml:mtext></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> the pressure measured/calibrated by a pressure meter in parallel to the sensor for molecule <inline-formula><mml:math id="M510" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula> (in Pa).</p>
      <p id="d1e7652">After these corrections, the time-response correction is performed by the procedure described above, and the ratio is determined by simple
linear regression on a scatterplot, using only data with <inline-formula><mml:math id="M511" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratio higher than 2 <inline-formula><mml:math id="M512" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppm</mml:mi></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e7674">For water, the mixing ratio is obtained from the following equations (Wagner and Pruß, 2002):

              <disp-formula specific-use="gather" content-type="numbered"><mml:math id="M513" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="App1.Ch1.S2.E3"><mml:mtd><mml:mtext>B2</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi>X</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">6</mml:mn></mml:msup><mml:mo>⋅</mml:mo><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mi>P</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.S2.E4"><mml:mtd><mml:mtext>B3</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mo>⋅</mml:mo><mml:mtext>RH</mml:mtext><mml:mo>⋅</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mtext>ws</mml:mtext></mml:msub></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="App1.Ch1.S2.E5"><mml:mtd><mml:mtext>B4</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mi>P</mml:mi><mml:mtext>ws</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:mi>exp⁡</mml:mi><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mn mathvariant="normal">273.15</mml:mn><mml:mo>+</mml:mo><mml:mi>T</mml:mi></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>⋅</mml:mo><mml:mi>f</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

          where <inline-formula><mml:math id="M514" display="inline"><mml:mrow><mml:msub><mml:mi>X</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the water dry molar mixing ratio; <inline-formula><mml:math id="M515" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the water vapour pressure (in Pa); <inline-formula><mml:math id="M516" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula> the measured ambient pressure  (in Pa); RH the relative humidity (in %); <inline-formula><mml:math id="M517" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mtext>ws</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> the water saturation vapour pressure (in Pa); <inline-formula><mml:math id="M518" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the water critical pressure (in Pa); <inline-formula><mml:math id="M519" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the water critical temperature (in K); <inline-formula><mml:math id="M520" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> the measured ambient temperature (in K); and <inline-formula><mml:math id="M521" display="inline"><mml:mrow><mml:mi>f</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> a function of <inline-formula><mml:math id="M522" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M523" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> involving six parameters.</p>
      <p id="d1e7922">MultiGAS data are processed with MATLAB. The following implementation was used (Arellano et al., 2017):
<list list-type="order"><list-item>
      <p id="d1e7927">Apply calibration constants and corrections for <inline-formula><mml:math id="M524" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M525" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> and RH.</p></list-item><list-item>
      <p id="d1e7945">Define time series for comparison, e.g. y1 (<inline-formula><mml:math id="M526" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and y2 (<inline-formula><mml:math id="M527" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e7970">y1 = <inline-formula><mml:math id="M528" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>v; %Volcanic <inline-formula><mml:math id="M529" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> time series</p>
      <p id="d1e7995">y2 = <inline-formula><mml:math id="M530" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>v; %Volcanic <inline-formula><mml:math id="M531" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> time series</p></list-item><list-item>
      <p id="d1e8021">Define a time vector at high resolution (e.g. 0.1 <inline-formula><mml:math id="M532" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e8032">dt = 0:0.1:100; % time-step vector</p><?xmltex \hack{\newpage}?></list-item><list-item>
      <p id="d1e8037">Resample signal at high time resolution.</p>
      <p id="d1e8040">y1hr = (interp1(1:length(y1),y1,1:0.1:length(y1)))'; % resample signal 1 at a x10 higher resolution</p>
      <p id="d1e8043">y2hr = (interp1(1:length(y2),y2,1:0.1:length(y2)))'; % resample signal 1 at a x10 higher resolution</p></list-item><list-item>
      <p id="d1e8047">Create a matrix of signals modelled with different response parameters, applying fist-order sensor theory.</p>
      <p id="d1e8050">for k = 1:length(dt)</p>
      <p id="d1e8053">y1t(:,k) = (k-1)*0.1*diff(y1hr)+y1hr(2:end,1); % signal 1</p>
      <p id="d1e8056">y2t(:,k) = (k-1)*0.1*diff(y2hr)+y2hr(2:end,1); % signal 2</p>
      <p id="d1e8059">end</p></list-item><list-item>
      <p id="d1e8063">Calculate all correlation matrices between the two signals.</p>
      <p id="d1e8066">for i = 1:length(dt)</p>
      <p id="d1e8069">for j = 1:length(dt)</p>
      <p id="d1e8072">cc = corrcoef(y1t(:,i),y2t(:,j));</p>
      <p id="d1e8075">CC(i,j) = cc(1,2);</p>
      <p id="d1e8079">end</p>
      <p id="d1e8082">end</p></list-item><list-item>
      <p id="d1e8086">Find parameters that give the highest correlation between the signals.</p>
      <p id="d1e8089">[A,I] = max(max(CC,[],2),[],1);</p>
      <p id="d1e8092">[B,J] = max(max(CC,[],1),[],2);</p></list-item><list-item>
      <p id="d1e8096">Determine the time-response parameters and level of correlation.</p>
      <p id="d1e8099">tau1 = dt(I);</p>
      <p id="d1e8102">tau2 = dt(J);</p>
      <p id="d1e8105">corr = A;</p></list-item><list-item>
      <p id="d1e8109">Resample the signals at original resolution but without effect of response time.</p>
      <p id="d1e8112">Timehr = (Time(1):mean(diff(Time))/10:Time(end))';</p>
      <p id="d1e8115">y1tlr = interp1(Timehr(2:end),y1t(:,I),Time(2:end));</p>
      <p id="d1e8118">y2tlr = interp1(Timehr(2:end),y2t(:,J),Time(2:end));</p></list-item><list-item>
      <p id="d1e8122">Apply linear regression to find ratio, excluding possible outliers.</p>
      <p id="d1e8125">LinearEqn = 'a+b*x';</p>
      <p id="d1e8128">f1 = fit(y1tlr,y2tlr,LinearEqn,'Start',[0,1],'Exclude',<?xmltex \hack{\break}?>(y1tlr<inline-formula><mml:math id="M533" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula>0)&amp;(y1tlr<inline-formula><mml:math id="M534" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula>1000)&amp;(y2tlr<inline-formula><mml:math id="M535" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula>0)&amp;(y2tlr<inline-formula><mml:math id="M536" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula>900));</p></list-item></list></p><?xmltex \hack{\newpage}?>
</app>

<?pagebreak page4274?><app id="App1.Ch1.S3">
  <?xmltex \currentcnt{C}?><label>Appendix C</label><title>Analysis of MobileDOAS data</title>
      <p id="d1e8170">To obtain the <inline-formula><mml:math id="M537" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux, the integral of <inline-formula><mml:math id="M538" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column densities across a surface perpendicular to the plume direction is multiplied
by plume speed. Plume direction is obtained from the vector joining the source (crater) and the peak column density in the traverse. Plume speed is
obtained preferably by the drone drift method.</p>
      <p id="d1e8195">To obtain the <inline-formula><mml:math id="M539" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column densities, each spectrum in the traverse is divided by a spectrum from a region outside of the plume (which could
be identified a posteriori as one with minimum column density). The transmittance spectrum is fitted to a model following the DOAS method (Platt and
Stutz, 2008). The model includes absorption cross-sections of <inline-formula><mml:math id="M540" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Vandaele et al., 1994) and <inline-formula><mml:math id="M541" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Voigt et al., 2001), a synthetic
Ring-effect pseudo-absorber (from Chance and Kurucz, 2010) and a polynomial of fifth order to account for broadband extinction due mainly to
scattering. The fitting is performed between 310 and 325 <inline-formula><mml:math id="M542" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, and the shift is allowed for a spectrum with high <inline-formula><mml:math id="M543" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> signal and then fixed
for the rest of the spectra in the same traverse.</p>
      <p id="d1e8250">Data are processed with MobileDOAS software (Johansson et al., 2019).</p><?xmltex \hack{\clearpage}?>
</app>
  </app-group><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e8258">All data files presented in this article can be found at <ext-link xlink:href="https://doi.org/10.5878/q3wv-ty69" ext-link-type="DOI">10.5878/q3wv-ty69</ext-link> (Galle and Arellano, 2021).</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e8264">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-14-4255-2021-supplement" xlink:title="pdf">https://doi.org/10.5194/amt-14-4255-2021-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e8273">SA, NB, TPF, AG, BG, GG, EJL, KM, SN, JR, TR and KW participated in the field measurements. GG piloted the drone. SA and BG collected and analysed Chalmers data (MultiGAS and MobileDOAS). TPF and SN collected and analysed UNM data (Isotope analysis). NB, AG, TH and JR collected and analysed UM data (Sunkist and denuders). GG and TK built the drone. SA, VC and JX built and calibrated the Chalmers payloads. SN built the UNM payload. NB, AG, TH and JR built and calibrated the UM payload. EJL coordinated the field campaign with support from II, KM, TR and KW. All authors contributed to writing the article.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e8279">The authors declare that they have no conflict of interest.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e8285">We thank the Rabaul Volcano Observatory (RVO) and the community of Baliau village on Manam island for their assistance and hospitality. We thank the PX4 autopilot development team for their open-source flight control software.</p><p id="d1e8287">The main funding for this work comes from the Aerial Based Observations of Volcanic Emissions (ABOVE) project, funded by the Alfred P. Sloan Foundation through their support of the Deep Carbon Observatory (DCO) project. The drone and Chalmers payloads were supported by FORMAS, the Swedish Research Council for Sustainable Development. Santiago Arellano was supported by the Swedish National Space Agency (Dnr 149/18). Kieran Wood was supported by the NCNR EPSRC grant (EP/R02572X/1). Emma J. Liu acknowledges support from a Leverhulme Early Career Fellowship. Tom Richardson was supported by the EPSRC CASCADE programme grant (EP/R009953/1).</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e8292">This research has been supported by the Alfred P. Sloan Foundation (Aerial Based Observations of Volcanic Emissions (ABOVE) project), the Swedish Research Council for Sustainable Development (FORMAS), the Swedish National Space Agency (grant non. Dnr 149/18), the NCNR EPSRC grant (grant no. EP/R02572X/1), Leverhulme Early Career Fellowship, and the EPSRC CASCADE programme grant (grant no. EP/R009953/1).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e8298">This paper was edited by Francis Pope and reviewed by Peter Kelly and one anonymous referee.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><?label 1?><mixed-citation>Aiuppa, A., Federico, C., Giudice, G., and Gurrieri, S.:
Chemical mapping of a fumarolic field: La Fossa Crater, Vulcano Island (Aeolian Islands, Italy), Geophys. Res. Lett.,
32, L13309, <ext-link xlink:href="https://doi.org/10.1029/2005GL023207" ext-link-type="DOI">10.1029/2005GL023207</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><?label 2?><mixed-citation>Aiuppa, A., Fischer, T. P., Plank, T., and Bani, P.:
<inline-formula><mml:math id="M544" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux emissions from the Earth's most actively degassing volcanoes, 2005–2015,
Sci. Rep.,
9, 5442, <ext-link xlink:href="https://doi.org/10.1038/s41598-019-41901-y" ext-link-type="DOI">10.1038/s41598-019-41901-y</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><?label 3?><mixed-citation>Arellano, S., Galle, B., Mulina, K., Wallius, J., McCormick, B., Salem, L., D'aleo, R., Barry, P., and Itikarai, I.:
Report on volcanic plume measurements on volcanoes in Papua New Guinea,
Chalmers University of Technology, Gothenburg, Sweden,
available at: <uri>https://research.chalmers.se/publication/254380</uri> (last access: 3 June 2021), 2017.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><?label 5?><mixed-citation>Beecken, J., Mellqvist, J., Salo, K., Ekholm, J., Jalkanen, J.-P., Johansson, L., Litvinenko, V., Volodin, K., and Frank-Kamenetsky, D. A.: Emission factors of <inline-formula><mml:math id="M545" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M546" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mtext mathvariant="italic">x</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and particles from ships in Neva Bay from ground-based and helicopter-borne measurements and AIS-based modeling, Atmos. Chem. Phys., 15, 5229–5241, <ext-link xlink:href="https://doi.org/10.5194/acp-15-5229-2015" ext-link-type="DOI">10.5194/acp-15-5229-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><?label 7?><mixed-citation>Carn, S., Fioletov, V., McLinden, C. A., Li, C., and Krotkov, N. A.:
A decade of global volcanic <inline-formula><mml:math id="M547" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emissions measured from space,
Sci. Rep.,
7, 44095, <ext-link xlink:href="https://doi.org/10.1038/srep44095" ext-link-type="DOI">10.1038/srep44095</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><?label 6?><mixed-citation>
Chance, K. and Kurucz, R. L.:
An improved high-resolution solar reference spectrum for Earth's atmosphere measurements in the ultraviolet, visible, and near infrared,
J. Quant. Spectrosc. Ra.,
111, 1289–1295, 2010.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><?label 8?><mixed-citation>Chiodini, G., Caliro, S., Aiuppa, A., Avino, R., Granieri, D., Moretti, R., and Parello F.:
First <inline-formula><mml:math id="M548" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>/<inline-formula><mml:math id="M549" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">12</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> isotopic characterisation of volcanic plume <inline-formula><mml:math id="M550" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>,
B. Volcanol.,
73, 531–542, 2011.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><?label 9?><mixed-citation>de Moor, J. M., Stix, J., Avard, G., Muller, C., Corrales, E., Diaz, J. A., Alan, A., Brenes, J., Pacheco, J., Aiuppa, A., and Fischer, T. P.:
Insights on Hydrothermal-Magmatic Interactions and Eruptive Processes at Poás Volcano (Costa Rica) From High-Frequency Gas Monitoring and Drone Measurements,
Geophys. Res. Lett.,
46, 1293–1302, <ext-link xlink:href="https://doi.org/10.1029/2018gl080301" ext-link-type="DOI">10.1029/2018gl080301</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><?label 10?><mixed-citation>Edmonds, M., Herd, H., Galle, B., and Oppenheimer, C.:
Automated, high time-resolution measurements of <inline-formula><mml:math id="M551" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux at Soufrière Hills Volcano, Montserrat, West Indies,
B. Volcanol.,
65, 578–586, <ext-link xlink:href="https://doi.org/10.1007/s00445-003-0286-x" ext-link-type="DOI">10.1007/s00445-003-0286-x</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><?label 11?><mixed-citation>Faivre-Pierret, R., Martin, D., and Sabroux, J. C.:
Contribution des Sondes Aérologiques Motorisées à l'Etude de la Physico–Chimie des Panaches Volcaniques,
B. Volcanol.,
43, 473–485, <ext-link xlink:href="https://doi.org/10.1007/BF02597686" ext-link-type="DOI">10.1007/BF02597686</ext-link>, 1980.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><?label 12?><mixed-citation>Fischer, T. P. and Chiodini, G.:
Volcanic, Magmatic and Hydrothermal Gas Discharges,
in: Encyclopedia of Volcanoes, Elsevier Science Direct, 2nd edn., 779–797,
<ext-link xlink:href="https://doi.org/10.1016/B978-0-12-385938-9.00045-6" ext-link-type="DOI">10.1016/B978-0-12-385938-9.00045-6</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><?label 13?><mixed-citation>Fischer, T. P. and Lopez, T. M.:
First airborne samples of a volcanic plume for <inline-formula><mml:math id="M552" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M553" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> determinations,
Geophys Res. Lett.,
43, 3272–3279, <ext-link xlink:href="https://doi.org/10.1002/2016GL068499" ext-link-type="DOI">10.1002/2016GL068499</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><?label 14?><mixed-citation>Fischer, T. P., Arellano, S., Carn, S., Aiuppa, A., Galle, B., Allard, P., Lopez, T., Shinohara, H., Kelly, P., Werner, C., Cardellini, C., and Chiodini, G.:
The emissions of <inline-formula><mml:math id="M554" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and other volatiles from the world's subaerial volcanoes,
Sci. Rep.,
9, 18716, <ext-link xlink:href="https://doi.org/10.1038/s41598-019-54682-1" ext-link-type="DOI">10.1038/s41598-019-54682-1</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><?label 15?><mixed-citation>Galle, B. and Arellano, S.: Volcanic gas measurements with drones on Manam Papua, Nya Guinea, Chalmers University of Technology, Department of Space, Earth and Environment, Swedish National Data Service [data set], Version 1, <ext-link xlink:href="https://doi.org/10.5878/q3wv-ty69" ext-link-type="DOI">10.5878/q3wv-ty69</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><?label 15?><mixed-citation>Galle, B., Oppenheimer, C., Geyer, A., McGonigle, A., Edmonds, M., Horrocks, L.:
A miniaturised ultraviolet spectrometer for remote sensing of <inline-formula><mml:math id="M555" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> fluxes: a new tool for volcano surveillance,
J. Volcanol. Geoth. Res.,
119, 241–254, <ext-link xlink:href="https://doi.org/10.1016/S0377-0273(02)00356-6" ext-link-type="DOI">10.1016/S0377-0273(02)00356-6</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><?label 16?><mixed-citation>Galle, B., Johansson, M., Rivera, C., Zhang, Y., Kihlman, M., Kern, C., Lehmann, T., Platt, U., Arellano S., and Hidalgo, S.:
Network for Observation of Volcanic and Atmospheric Change (NOVAC)—A global network for volcanic gas monitoring: Network layout and instrument description,
J. Geophys. Res.,
115, D05304 <ext-link xlink:href="https://doi.org/10.1029/2009JD011823" ext-link-type="DOI">10.1029/2009JD011823</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><?label 19?><mixed-citation>Gutmann, A., Bobrowski, N., Roberts, T. J., Rüdiger, J., and Hoffmann, T.:
Advances in Bromine Speciation in Volcanic Plumes,
Front. Earth Sci.,
6, 213, <ext-link xlink:href="https://doi.org/10.3389/feart.2018.00213" ext-link-type="DOI">10.3389/feart.2018.00213</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><?label 18?><mixed-citation>Gutmann, A., Bobrowski, N., Liotta, M., and Hoffmann, T.: Bromine Speciation in Volcanic Plumes: New in-situ Derivatization LC-MS Method for the Determination of Gaseous Hydrogen Bromide by Gas Diffusion Denuder Sampling, Atmos. Meas. Tech. Discuss. [preprint], <ext-link xlink:href="https://doi.org/10.5194/amt-2020-357" ext-link-type="DOI">10.5194/amt-2020-357</ext-link>, in review, 2020.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><?label 20?><mixed-citation>James, M. R., Carr, B., D'Arcy, F., Diefenbach, A., Dietterich, H., Fornaciai, A., Lev, E., Liu, E., Pieri, D., Rodgers, M., Smets, B., Terada, A., von Aulock, F., Walter, T., Wood, K., and Zorn, E.:
Volcanological applications of unoccupied aircraft systems (UAS): Developments, strategies, and future challenges,
Volcanica,
3, 67–114. <ext-link xlink:href="https://doi.org/10.30909/vol.03.01.67114" ext-link-type="DOI">10.30909/vol.03.01.67114</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><?label 21?><mixed-citation>
Johansson, M.:
Application of Passive DOAS for Studies of Megacity Air Pollution and Volcanic Gas Emissions,
PhD thesis,
Chalmers University of Technology, Gothenburg, Sweden, 64 pp., 2009.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><?label 22?><mixed-citation>Johansson, M., Galle, B., Zhang, Y., Rivera, C., and Chen, D.:
The Dual-Beam technique – single instrument measurements of plume height and plume speed, B. Volcanol., 71, 747–751, <ext-link xlink:href="https://doi.org/10.1007/s00445-008-0260-8" ext-link-type="DOI">10.1007/s00445-008-0260-8</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><?label 23?><mixed-citation>Johansson, M., Yang, Z., and Norgaard, D.:
MobileDOAS software v. 6.2,
available at: <uri>https://github.com/NOVACProject/MobileDOAS</uri> (last access: 4 June 2021), 2019.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><?label 25?><mixed-citation>Kelly, P. J., Kern, C., Roberts, T. J., Lopez, T., Werner, C., and Aiuppa, A.:
Rapid chemical evolution of tropospheric volcanic emissions from Redoubt Volcano, Alaska, based on observations of ozone and halogen-containing gases,
J. Volcanol. Geoth. Res.,
259, 317–333, <ext-link xlink:href="https://doi.org/10.1016/J.JVOLGEORES.2012.04.023" ext-link-type="DOI">10.1016/J.JVOLGEORES.2012.04.023</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><?label 26?><mixed-citation>Liu, E. J., Wood, K., Mason, E., Edmonds, M., Aiuppa, A., Giudice, G., Bitetto, M., Francofonte, V., Burrow, S., Richardson, T., Watson, M., Pering, T. D., Wilkes, T. C., McGonigle, A. J. S., Velasquez, G., Melgarejo, C., and Bucarey, C.:
Dynamics of outgassing and plume transport revealed by proximal unmanned aerial system (UAS) measurements at Volcán Villarrica, Chile,
Geochem. Geophy. Geosy.,
20, 730–750, <ext-link xlink:href="https://doi.org/10.1029/2018GC007692" ext-link-type="DOI">10.1029/2018GC007692</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><?label 27?><mixed-citation>Liu, E., Aiuppa, A., Alan, A., Arellano, S., Bitetto, M., Bobrowski, N., Carn, S., Clarkes, R., Corrales, E., de Moor, J., Diaz, J., Edmonds, M., Fischer, T., Freer, J., Fricke, G., Galle, B., Gerdes, G., Giudice, G., Gutmann, A., Hayer, C., Itikarai, I., Jones, J., Mason, E., McCormick, B., Mulina, K., Nowicki, S., Rahilly, K., Richardson, T., Rüdiger, J., Schipper, I., Watson, I., and Woods, K.:
Aerial strategies advance volcanic gas measurements at inaccessible, strongly degassing volcanoes,
Science Advances,
6, eabb9103, <ext-link xlink:href="https://doi.org/10.1126/sciadv.abb9103" ext-link-type="DOI">10.1126/sciadv.abb9103</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><?label 28?><mixed-citation>Lucic, G., Stix, J., and Wing, B.:
Structural controls on the emission of magmatic carbon dioxide gas, Long Valley Caldera, USA,
J. Geophys. Res.-Sol Ea.,
120, 2262–2278, <ext-link xlink:href="https://doi.org/10.1002/2014JB011760" ext-link-type="DOI">10.1002/2014JB011760</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><?label 29?><mixed-citation>Lübcke, P., Bobrowski, N., Arellano, S., Galle, B., Garzón, G., Vogel, L., and Platt, U.: <inline-formula><mml:math id="M556" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">BrO</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> molar ratios from scanning DOAS measurements in the NOVAC network, Solid Earth, 5, 409–424, <ext-link xlink:href="https://doi.org/10.5194/se-5-409-2014" ext-link-type="DOI">10.5194/se-5-409-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><?label 30?><mixed-citation>Mandon, C., Christenson, B., Schipper, I., Seward, T., and Garaebiti, E.:
Metal transport in volcanic plumes: A case study at White Island and Yasur volcanoes,
J. Volcanol. Geoth. Res.,
369, 155–171, <ext-link xlink:href="https://doi.org/10.1016/j.jvolgeores.2018.11.024" ext-link-type="DOI">10.1016/j.jvolgeores.2018.11.024</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><?label 31?><mixed-citation>
Marty, B. and Zimmermann, L.:
Volatiles (He, C, N, Ar) in mid-ocean ridge basalts: assessment of shallow-level fractionation and characterization of source composition,
Geochim. Cosmochim. Ac.,
63, 3619–3633, 1999.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><?label 32?><mixed-citation>
Mason, E., Edmonds, M., and Turchyn, A. V.:
Remobilization of crustal carbon may dominate volcanic arc emissions,
Science,
357, 290–294, 2017.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><?label 33?><mixed-citation>McGonigle, A. J. S., Aiuppa, A., Giudice, G., Tamburello, G., Hodson, A. J., and Gurrieri, S., Unmanned aerial vehicle measurements of volcanic carbondioxide fluxes, Geophys. Res. Lett., 35, L06303, <ext-link xlink:href="https://doi.org/10.1029/2007GL032508" ext-link-type="DOI">10.1029/2007GL032508</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><?label 33?><mixed-citation>Mellqvist, J., Beecken, J., Conde, V., and Ekholm, J.:
Surveillance of Sulfur Emissions from Ships in Danish Waters, final report to Danish Environmnetal Protecion agency, <ext-link xlink:href="https://doi.org/10.17196/DEPA.001" ext-link-type="DOI">10.17196/DEPA.001</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><?label 34?><mixed-citation>
Millán, M. M.:
Remote sensing of air pollutants. A study of some atmospheric scattering effects,
Atmos. Environ.,
14, 1241–1253, 1980.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><?label 35?><mixed-citation>Mori, T., Kazahaya, K., Ohwada, M., Hirabayashi, J., and Yoshikawa, S.:
Effect of UV scattering on <inline-formula><mml:math id="M557" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emission rate measurements.
Geophys. Res. Lett.,
33, L17513, <ext-link xlink:href="https://doi.org/10.1029/2006GL026285" ext-link-type="DOI">10.1029/2006GL026285</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><?label 36?><mixed-citation>Mori, T., Hashimoto, T., Terada, A., Yoshimoto, M., Kazahaya, R., Shinohara, H., and Tanaka, R.:
Volcanic plume measurements using a UAV for the 2014 Mt. Ontake eruption,
Earth Planets Space,
68, 49, <ext-link xlink:href="https://doi.org/10.1186/s40623-016-0418-0" ext-link-type="DOI">10.1186/s40623-016-0418-0</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><?label 38?><mixed-citation>
Pallas-Areny, R. and Webster, J. G.:
Sensors and Signal Conditioning,
Wiley, New York, 1991.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><?label 39?><mixed-citation>
Platt, U. and Stutz, J.:
Differential Optical Absorption Spectroscopy, Principles and Applications,
Physics of Earth and Space Environments, Springer, Berlin, Germany, 597 pp., ISBN 978-3-540-75776-4, 2008.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><?label 41?><mixed-citation>Rizzo, A. L., Jost, H.-J., Caracausi, A., Paonita, A., Liotta, M., and Martelli, M.:
Real-time measurements of the concentration and isotope composition of atmospheric and volcanic <inline-formula><mml:math id="M558" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at Mount Etna (Italy),
Geophys. Res. Lett.,
41, 2382–2389, 2014.</mixed-citation></ref>
      <?pagebreak page4277?><ref id="bib1.bib39"><label>39</label><?label 40?><mixed-citation>Rizzo, A. L., Liuzzo, M., Ancellin, M. A., and Jost, H. J.:
Real-time measurements of <inline-formula><mml:math id="M559" display="inline"><mml:mrow><mml:mi mathvariant="italic">δ</mml:mi><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M560" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration, and <inline-formula><mml:math id="M561" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in volcanic plume gases at Mount Etna, Italy, over 5 consecutive days,
Chem. Geol.,
411, 182–191, 2015.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><?label 42?><mixed-citation>Roberts, T. J., Martin, R. S., and Jourdain, L.: Reactive bromine chemistry in Mount Etna's volcanic plume: the influence of total Br, high-temperature processing, aerosol loading and plume–air mixing, Atmos. Chem. Phys., 14, 11201–11219, <ext-link xlink:href="https://doi.org/10.5194/acp-14-11201-2014" ext-link-type="DOI">10.5194/acp-14-11201-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><?label 43?><mixed-citation>Roberts, T. J., Lurton, T., Giudice, G., Liuzzo, M., Aiuppa, A., Coltelli, M., Vignelles, D., Salerno, G., Couté, B., Chartier, M., Baron, R., Saffell, J. R., and Scaillet, B.:
Validation of a novel Multi-Gas sensor for volcanic HCl alongside <inline-formula><mml:math id="M562" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">S</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M563" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at Mt. Etna,
B. Volcanol.,
79, 11201–11219, <ext-link xlink:href="https://doi.org/10.1007/s00445-017-1114-z" ext-link-type="DOI">10.1007/s00445-017-1114-z</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><?label 44?><mixed-citation>Rüdiger, J., Bobrowski, N., Liotta, M., and Hoffmann, T.:
Development and application of a sampling method for the determination of reactive halogen species in volcanic gas emissions,
Anal. Bioanal. Chem.,
409, 5975–5985, <ext-link xlink:href="https://doi.org/10.1007/s00216-017-0525-1" ext-link-type="DOI">10.1007/s00216-017-0525-1</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><?label 46?><mixed-citation>Rüdiger, J., Tirpitz, J.-L., de Moor, J. M., Bobrowski, N., Gutmann, A., Liuzzo, M., Ibarra, M., and Hoffmann, T.: Implementation of electrochemical, optical and denuder-based sensors and sampling techniques on UAV for volcanic gas measurements: examples from Masaya, Turrialba and Stromboli volcanoes, Atmos. Meas. Tech., 11, 2441–2457, <ext-link xlink:href="https://doi.org/10.5194/amt-11-2441-2018" ext-link-type="DOI">10.5194/amt-11-2441-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><?label 45?><mixed-citation>Rüdiger, J., Gutmann, A., Bobrowski, N., Liotta, M., de Moor, J. M., Sander, R., Dinger, F., Tirpitz, J.-L., Ibarra, M., Saballos, A., Martínez, M., Mendoza, E., Ferrufino, A., Stix, J., Valdés, J., Castro, J. M., and Hoffmann, T.: Halogen activation in the plume of Masaya volcano: field observations and box model investigations, Atmos. Chem. Phys., 21, 3371–3393, <ext-link xlink:href="https://doi.org/10.5194/acp-21-3371-2021" ext-link-type="DOI">10.5194/acp-21-3371-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><?label 47?><mixed-citation>Ryan, W. B. F., Carbotte, S. M., Coplan, J. O., O'Hara, S., Melkonian, A., Arko, R., Weissel, R. A., Ferrini, V., Goodwillie, A., Nitsche, F., Bonczkowski, J., and Zemsky, R.:
Global Multi-Resolution Topography synthesis,
Geochem. Geophy. Geosy.,
10, Q03014, <ext-link xlink:href="https://doi.org/10.1029/2008GC002332" ext-link-type="DOI">10.1029/2008GC002332</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><?label 48?><mixed-citation>
Sano, Y. and Marty, B.:
Origin of carbon in fumarolic gas from island arcs,
Chem. Geol.,
119, 265–274, 1995.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><?label 49?><mixed-citation>Sano, Y. and Williams, S. N.:
Fluxes of mantle and subducted carbon along convergent plate boundaries,
Geophys. Res. Lett.,
23, 2749–2752, <ext-link xlink:href="https://doi.org/10.1029/96GL02260" ext-link-type="DOI">10.1029/96GL02260</ext-link>, 1996.</mixed-citation></ref>
      <ref id="bib1.bib48"><label>48</label><?label 50?><mixed-citation>Schellenberg, B., Richardson, T., Watson, M., Greatwood, C., Clarke, R., Thomas, R., Wood, K., Freer, J., Thomas, H., Liu, E., Salama, F., and Chigna, G.:
Remote sensing and identification of volcanic plumes using fixed-wing UAVs over Volcán de Fuego, Guatemala,
J. Field Robot., 36, 1192—1211,
<ext-link xlink:href="https://doi.org/10.1002/rob.21896" ext-link-type="DOI">10.1002/rob.21896</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><?label 51?><mixed-citation>Sharp, Z. D.:
Principles of Stable Isoptope Geochemistry,
Pearson Prentice Hall, New Jersey, 344 pp., 2007.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib50"><label>50</label><?label 52?><mixed-citation>
Shinohara, H.:
A new technique to estimate volcanic gas composition: plume measurements with a portable multi-sensor system,
J. Volcanol. Geoth. Res.,
143, 319–333, 2005.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><?label 53?><mixed-citation>Stix, J., de Moor, J. M., Rüdiger, J., Alan, A., Corrales, E., D'Arcy, F., Diaz, J. A., and Liotta, M.:
Using Drones and Miniaturized Instrumentation to Study Degassing at Turrialba and Masaya Volcanoes, Central America,
J. Geophys. Res.-Sol. Ea.,
123, 6501–6520, <ext-link xlink:href="https://doi.org/10.1029/2018jb015655" ext-link-type="DOI">10.1029/2018jb015655</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib52"><label>52</label><?label 54?><mixed-citation>
Stoiber, R., Malinconico Jr., L., Williams, S. N.:
Use of the correlation spectrometer at volcanoes,
in: Forecasting Volcanic Events. Developments in Volcanology,
edited by: Tazieff, H. and Sabroux, J. C.,
Elsevier Science Publisher, Amsterdam, the Netherlands, 425-444, 1983.</mixed-citation></ref>
      <ref id="bib1.bib53"><label>53</label><?label 55?><mixed-citation>Syahbana, D. K., Kasbani, K., Suantika, G., Prambada, O., Andreas, A. S., Saing, U. B., Kunrat, S. L., Andreastuti, S., Martanto, M., Kriswati, E., Suparman, Y., Humaida, H., Ogburn, S., Kelly, P. J., Wellik, J., Wright, H. M. N., Pesicek, J. D., Wessels, R., Kern, C., Lisowski, M., Diefenbach, A., Poland, M., Beauducel, F., Pallister, J., Vaughan, R. G., and Lowenstern, J. B.:
The 2017–19 activity at Mount Agung in Bali (Indonesia): Intense unrest, monitoring, crisis response, evacuation, and eruption,
Sci. Rep.,
9, 8848, <ext-link xlink:href="https://doi.org/10.1038/s41598-019-45295-9" ext-link-type="DOI">10.1038/s41598-019-45295-9</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><?label 56?><mixed-citation>
Textor, C., Graf, H.-F., Timmreck, C., and Robock, A. (Eds.):
Emissions from volcanoes: Emissions of Atmospheric Trace Compounds, Advances in Global Change Research, 18,
Springer Netherlands, Dordrecht, 2004.</mixed-citation></ref>
      <ref id="bib1.bib55"><label>55</label><?label 57?><mixed-citation>Vandaele, A. C., Simon, P. C., Guilmot, J. M., Carleer, M., and Colin, R.:
<inline-formula><mml:math id="M564" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> Absorption cross-section measurement in the UV using a Fourier transform spectrometer,
J. Geophys. Res.,
99, 25599–25605, 1994.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><?label 58?><mixed-citation>
van Geldern, R., Nowak, M. E., Zimmer, M., Szizybalski, A., Myrttinen, A., Barth, J. A., and Jost, H. J.:
Field-based stable isotope analysis of carbon dioxide by mid-infrared laser spectroscopy for carbon capture and storage monitoring,
Anal. Chem.,
86, 12191–12198, 2014.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><?label 59?><mixed-citation>Venzke, E. (Ed.):
Volcanoes of the World v. 4.8.3., Global_Volcanism_Program, Manam (251020),
Smithsonian Institution, <ext-link xlink:href="https://doi.org/10.5479/si.GVP.VOTW4-2013" ext-link-type="DOI">10.5479/si.GVP.VOTW4-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib58"><label>58</label><?label 60?><mixed-citation>Villa, T. F., Gonzalez, F., Miljievic, B., Ristovski, Z. D., and Morawska, L:
An Overview of Small Unmanned Aerial Vehicles for Air Quality Measurements: Present Applications and Future Prospectives,
Sensors, 16, 1072, <ext-link xlink:href="https://doi.org/10.3390/s16071072" ext-link-type="DOI">10.3390/s16071072</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib59"><label>59</label><?label 61?><mixed-citation>Voigt, S., Orphal, J., Bogumil, K., and Burrows, J. P.:
The temperature dependence (203–293 <inline-formula><mml:math id="M565" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">K</mml:mi></mml:mrow></mml:math></inline-formula>) of the absorption cross sections of <inline-formula><mml:math id="M566" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in the 230–850 <inline-formula><mml:math id="M567" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> region measured by Fourier-Transform spectroscopy,
J. Photoch. Photobio. A,
143, 1–9, 2001.</mixed-citation></ref>
      <ref id="bib1.bib60"><label>60</label><?label 62?><mixed-citation>
Wagner, W. and Pruß, A.:
The IAPWS Formulation 1995 for the Thermodynamic Properties of Ordinary Water Substance for General and Scientific Use,
J. Phys. Chem. Ref. Data,
31, 387–535, 2002.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>A multi-purpose, multi-rotor drone system for long-range and high-altitude volcanic gas plume measurements</article-title-html>
<abstract-html><p>A multi-rotor drone has been adapted for studies of volcanic gas plumes. This adaptation includes improved capacity for high-altitude and long-range, real-time SO<sub>2</sub> concentration monitoring, long-range manual control, remotely activated bag sampling and plume speed measurement
capability. The drone is capable of acting as a stable platform for various instrument configurations, including multi-component gas analysis system (MultiGAS) instruments for in situ
measurements of SO<sub>2</sub>, H<sub>2</sub>S, and CO<sub>2</sub> concentrations in the gas plume and portable differential optical absorption spectrometer (MobileDOAS) instruments for spectroscopic
measurement of total SO<sub>2</sub> emission rate, remotely controlled gas sampling in bags and sampling with gas denuders for posterior analysis on
the ground of isotopic composition and halogens.</p><p>The platform we present was field-tested during three campaigns in Papua New Guinea: in 2016 at Tavurvur, Bagana and Ulawun volcanoes, in 2018
at Tavurvur and Langila volcanoes and in 2019 at Tavurvur and Manam volcanoes, as well as in Mt. Etna in Italy in 2017.</p><p>This paper describes the drone platform and the multiple payloads, the various measurement strategies and an algorithm to correct for different
response times of MultiGAS sensors. Specifically, we emphasize the need for an adaptive flight path, together with live data transmission of a plume
tracer (such as SO<sub>2</sub> concentration) to the ground station, to ensure optimal plume interception when operating beyond the visual line of
sight. We present results from a comprehensive plume characterization obtained during a field deployment at Manam volcano in May 2019. The Papua New
Guinea region, and particularly Manam volcano, has not been extensively studied for volcanic gases due to its remote location, inaccessible summit
region and high level of volcanic activity. We demonstrate that the combination of a multi-rotor drone with modular payloads is a versatile solution to
obtain the flux and composition of volcanic plumes, even for the case of a highly active volcano with a high-altitude plume such as
Manam. Drone-based measurements offer a valuable solution to volcano research and monitoring applications and provide an alternative and
complementary method to ground-based and direct sampling of volcanic gases.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Aiuppa, A., Federico, C., Giudice, G., and Gurrieri, S.:
Chemical mapping of a fumarolic field: La Fossa Crater, Vulcano Island (Aeolian Islands, Italy), Geophys. Res. Lett.,
32, L13309, <a href="https://doi.org/10.1029/2005GL023207" target="_blank">https://doi.org/10.1029/2005GL023207</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Aiuppa, A., Fischer, T. P., Plank, T., and Bani, P.:
CO<sub>2</sub> flux emissions from the Earth's most actively degassing volcanoes, 2005–2015,
Sci. Rep.,
9, 5442, <a href="https://doi.org/10.1038/s41598-019-41901-y" target="_blank">https://doi.org/10.1038/s41598-019-41901-y</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Arellano, S., Galle, B., Mulina, K., Wallius, J., McCormick, B., Salem, L., D'aleo, R., Barry, P., and Itikarai, I.:
Report on volcanic plume measurements on volcanoes in Papua New Guinea,
Chalmers University of Technology, Gothenburg, Sweden,
available at: <a href="https://research.chalmers.se/publication/254380" target="_blank"/> (last access: 3 June 2021), 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Beecken, J., Mellqvist, J., Salo, K., Ekholm, J., Jalkanen, J.-P., Johansson, L., Litvinenko, V., Volodin, K., and Frank-Kamenetsky, D. A.: Emission factors of SO<sub>2</sub>, NO<sub>x</sub> and particles from ships in Neva Bay from ground-based and helicopter-borne measurements and AIS-based modeling, Atmos. Chem. Phys., 15, 5229–5241, <a href="https://doi.org/10.5194/acp-15-5229-2015" target="_blank">https://doi.org/10.5194/acp-15-5229-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Carn, S., Fioletov, V., McLinden, C. A., Li, C., and Krotkov, N. A.:
A decade of global volcanic SO<sub>2</sub> emissions measured from space,
Sci. Rep.,
7, 44095, <a href="https://doi.org/10.1038/srep44095" target="_blank">https://doi.org/10.1038/srep44095</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Chance, K. and Kurucz, R. L.:
An improved high-resolution solar reference spectrum for Earth's atmosphere measurements in the ultraviolet, visible, and near infrared,
J. Quant. Spectrosc. Ra.,
111, 1289–1295, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Chiodini, G., Caliro, S., Aiuppa, A., Avino, R., Granieri, D., Moretti, R., and Parello F.:
First <sup>13</sup>C/<sup>12</sup>C isotopic characterisation of volcanic plume CO<sub>2</sub>,
B. Volcanol.,
73, 531–542, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
de Moor, J. M., Stix, J., Avard, G., Muller, C., Corrales, E., Diaz, J. A., Alan, A., Brenes, J., Pacheco, J., Aiuppa, A., and Fischer, T. P.:
Insights on Hydrothermal-Magmatic Interactions and Eruptive Processes at Poás Volcano (Costa Rica) From High-Frequency Gas Monitoring and Drone Measurements,
Geophys. Res. Lett.,
46, 1293–1302, <a href="https://doi.org/10.1029/2018gl080301" target="_blank">https://doi.org/10.1029/2018gl080301</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Edmonds, M., Herd, H., Galle, B., and Oppenheimer, C.:
Automated, high time-resolution measurements of SO<sub>2</sub> flux at Soufrière Hills Volcano, Montserrat, West Indies,
B. Volcanol.,
65, 578–586, <a href="https://doi.org/10.1007/s00445-003-0286-x" target="_blank">https://doi.org/10.1007/s00445-003-0286-x</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Faivre-Pierret, R., Martin, D., and Sabroux, J. C.:
Contribution des Sondes Aérologiques Motorisées à l'Etude de la Physico–Chimie des Panaches Volcaniques,
B. Volcanol.,
43, 473–485, <a href="https://doi.org/10.1007/BF02597686" target="_blank">https://doi.org/10.1007/BF02597686</a>, 1980.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Fischer, T. P. and Chiodini, G.:
Volcanic, Magmatic and Hydrothermal Gas Discharges,
in: Encyclopedia of Volcanoes, Elsevier Science Direct, 2nd edn., 779–797,
<a href="https://doi.org/10.1016/B978-0-12-385938-9.00045-6" target="_blank">https://doi.org/10.1016/B978-0-12-385938-9.00045-6</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Fischer, T. P. and Lopez, T. M.:
First airborne samples of a volcanic plume for <i>δ</i><sup>13</sup>C of CO<sub>2</sub> determinations,
Geophys Res. Lett.,
43, 3272–3279, <a href="https://doi.org/10.1002/2016GL068499" target="_blank">https://doi.org/10.1002/2016GL068499</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Fischer, T. P., Arellano, S., Carn, S., Aiuppa, A., Galle, B., Allard, P., Lopez, T., Shinohara, H., Kelly, P., Werner, C., Cardellini, C., and Chiodini, G.:
The emissions of CO<sub>2</sub> and other volatiles from the world's subaerial volcanoes,
Sci. Rep.,
9, 18716, <a href="https://doi.org/10.1038/s41598-019-54682-1" target="_blank">https://doi.org/10.1038/s41598-019-54682-1</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Galle, B. and Arellano, S.: Volcanic gas measurements with drones on Manam Papua, Nya Guinea, Chalmers University of Technology, Department of Space, Earth and Environment, Swedish National Data Service [data set], Version 1, <a href="https://doi.org/10.5878/q3wv-ty69" target="_blank">https://doi.org/10.5878/q3wv-ty69</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Galle, B., Oppenheimer, C., Geyer, A., McGonigle, A., Edmonds, M., Horrocks, L.:
A miniaturised ultraviolet spectrometer for remote sensing of SO<sub>2</sub> fluxes: a new tool for volcano surveillance,
J. Volcanol. Geoth. Res.,
119, 241–254, <a href="https://doi.org/10.1016/S0377-0273(02)00356-6" target="_blank">https://doi.org/10.1016/S0377-0273(02)00356-6</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Galle, B., Johansson, M., Rivera, C., Zhang, Y., Kihlman, M., Kern, C., Lehmann, T., Platt, U., Arellano S., and Hidalgo, S.:
Network for Observation of Volcanic and Atmospheric Change (NOVAC)—A global network for volcanic gas monitoring: Network layout and instrument description,
J. Geophys. Res.,
115, D05304 <a href="https://doi.org/10.1029/2009JD011823" target="_blank">https://doi.org/10.1029/2009JD011823</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Gutmann, A., Bobrowski, N., Roberts, T. J., Rüdiger, J., and Hoffmann, T.:
Advances in Bromine Speciation in Volcanic Plumes,
Front. Earth Sci.,
6, 213, <a href="https://doi.org/10.3389/feart.2018.00213" target="_blank">https://doi.org/10.3389/feart.2018.00213</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Gutmann, A., Bobrowski, N., Liotta, M., and Hoffmann, T.: Bromine Speciation in Volcanic Plumes: New in-situ Derivatization LC-MS Method for the Determination of Gaseous Hydrogen Bromide by Gas Diffusion Denuder Sampling, Atmos. Meas. Tech. Discuss. [preprint], <a href="https://doi.org/10.5194/amt-2020-357" target="_blank">https://doi.org/10.5194/amt-2020-357</a>, in review, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
James, M. R., Carr, B., D'Arcy, F., Diefenbach, A., Dietterich, H., Fornaciai, A., Lev, E., Liu, E., Pieri, D., Rodgers, M., Smets, B., Terada, A., von Aulock, F., Walter, T., Wood, K., and Zorn, E.:
Volcanological applications of unoccupied aircraft systems (UAS): Developments, strategies, and future challenges,
Volcanica,
3, 67–114. <a href="https://doi.org/10.30909/vol.03.01.67114" target="_blank">https://doi.org/10.30909/vol.03.01.67114</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Johansson, M.:
Application of Passive DOAS for Studies of Megacity Air Pollution and Volcanic Gas Emissions,
PhD thesis,
Chalmers University of Technology, Gothenburg, Sweden, 64 pp., 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Johansson, M., Galle, B., Zhang, Y., Rivera, C., and Chen, D.:
The Dual-Beam technique – single instrument measurements of plume height and plume speed, B. Volcanol., 71, 747–751, <a href="https://doi.org/10.1007/s00445-008-0260-8" target="_blank">https://doi.org/10.1007/s00445-008-0260-8</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Johansson, M., Yang, Z., and Norgaard, D.:
MobileDOAS software v. 6.2,
available at: <a href="https://github.com/NOVACProject/MobileDOAS" target="_blank"/> (last access: 4 June 2021), 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Kelly, P. J., Kern, C., Roberts, T. J., Lopez, T., Werner, C., and Aiuppa, A.:
Rapid chemical evolution of tropospheric volcanic emissions from Redoubt Volcano, Alaska, based on observations of ozone and halogen-containing gases,
J. Volcanol. Geoth. Res.,
259, 317–333, <a href="https://doi.org/10.1016/J.JVOLGEORES.2012.04.023" target="_blank">https://doi.org/10.1016/J.JVOLGEORES.2012.04.023</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Liu, E. J., Wood, K., Mason, E., Edmonds, M., Aiuppa, A., Giudice, G., Bitetto, M., Francofonte, V., Burrow, S., Richardson, T., Watson, M., Pering, T. D., Wilkes, T. C., McGonigle, A. J. S., Velasquez, G., Melgarejo, C., and Bucarey, C.:
Dynamics of outgassing and plume transport revealed by proximal unmanned aerial system (UAS) measurements at Volcán Villarrica, Chile,
Geochem. Geophy. Geosy.,
20, 730–750, <a href="https://doi.org/10.1029/2018GC007692" target="_blank">https://doi.org/10.1029/2018GC007692</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Liu, E., Aiuppa, A., Alan, A., Arellano, S., Bitetto, M., Bobrowski, N., Carn, S., Clarkes, R., Corrales, E., de Moor, J., Diaz, J., Edmonds, M., Fischer, T., Freer, J., Fricke, G., Galle, B., Gerdes, G., Giudice, G., Gutmann, A., Hayer, C., Itikarai, I., Jones, J., Mason, E., McCormick, B., Mulina, K., Nowicki, S., Rahilly, K., Richardson, T., Rüdiger, J., Schipper, I., Watson, I., and Woods, K.:
Aerial strategies advance volcanic gas measurements at inaccessible, strongly degassing volcanoes,
Science Advances,
6, eabb9103, <a href="https://doi.org/10.1126/sciadv.abb9103" target="_blank">https://doi.org/10.1126/sciadv.abb9103</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Lucic, G., Stix, J., and Wing, B.:
Structural controls on the emission of magmatic carbon dioxide gas, Long Valley Caldera, USA,
J. Geophys. Res.-Sol Ea.,
120, 2262–2278, <a href="https://doi.org/10.1002/2014JB011760" target="_blank">https://doi.org/10.1002/2014JB011760</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Lübcke, P., Bobrowski, N., Arellano, S., Galle, B., Garzón, G., Vogel, L., and Platt, U.: BrO∕SO<sub>2</sub> molar ratios from scanning DOAS measurements in the NOVAC network, Solid Earth, 5, 409–424, <a href="https://doi.org/10.5194/se-5-409-2014" target="_blank">https://doi.org/10.5194/se-5-409-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Mandon, C., Christenson, B., Schipper, I., Seward, T., and Garaebiti, E.:
Metal transport in volcanic plumes: A case study at White Island and Yasur volcanoes,
J. Volcanol. Geoth. Res.,
369, 155–171, <a href="https://doi.org/10.1016/j.jvolgeores.2018.11.024" target="_blank">https://doi.org/10.1016/j.jvolgeores.2018.11.024</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Marty, B. and Zimmermann, L.:
Volatiles (He, C, N, Ar) in mid-ocean ridge basalts: assessment of shallow-level fractionation and characterization of source composition,
Geochim. Cosmochim. Ac.,
63, 3619–3633, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Mason, E., Edmonds, M., and Turchyn, A. V.:
Remobilization of crustal carbon may dominate volcanic arc emissions,
Science,
357, 290–294, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
McGonigle, A. J. S., Aiuppa, A., Giudice, G., Tamburello, G., Hodson, A. J., and Gurrieri, S., Unmanned aerial vehicle measurements of volcanic carbondioxide fluxes, Geophys. Res. Lett., 35, L06303, <a href="https://doi.org/10.1029/2007GL032508" target="_blank">https://doi.org/10.1029/2007GL032508</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Mellqvist, J., Beecken, J., Conde, V., and Ekholm, J.:
Surveillance of Sulfur Emissions from Ships in Danish Waters, final report to Danish Environmnetal Protecion agency, <a href="https://doi.org/10.17196/DEPA.001" target="_blank">https://doi.org/10.17196/DEPA.001</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Millán, M. M.:
Remote sensing of air pollutants. A study of some atmospheric scattering effects,
Atmos. Environ.,
14, 1241–1253, 1980.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Mori, T., Kazahaya, K., Ohwada, M., Hirabayashi, J., and Yoshikawa, S.:
Effect of UV scattering on SO<sub>2</sub> emission rate measurements.
Geophys. Res. Lett.,
33, L17513, <a href="https://doi.org/10.1029/2006GL026285" target="_blank">https://doi.org/10.1029/2006GL026285</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Mori, T., Hashimoto, T., Terada, A., Yoshimoto, M., Kazahaya, R., Shinohara, H., and Tanaka, R.:
Volcanic plume measurements using a UAV for the 2014 Mt. Ontake eruption,
Earth Planets Space,
68, 49, <a href="https://doi.org/10.1186/s40623-016-0418-0" target="_blank">https://doi.org/10.1186/s40623-016-0418-0</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Pallas-Areny, R. and Webster, J. G.:
Sensors and Signal Conditioning,
Wiley, New York, 1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Platt, U. and Stutz, J.:
Differential Optical Absorption Spectroscopy, Principles and Applications,
Physics of Earth and Space Environments, Springer, Berlin, Germany, 597 pp., ISBN 978-3-540-75776-4, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Rizzo, A. L., Jost, H.-J., Caracausi, A., Paonita, A., Liotta, M., and Martelli, M.:
Real-time measurements of the concentration and isotope composition of atmospheric and volcanic CO<sub>2</sub> at Mount Etna (Italy),
Geophys. Res. Lett.,
41, 2382–2389, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
Rizzo, A. L., Liuzzo, M., Ancellin, M. A., and Jost, H. J.:
Real-time measurements of <i>δ</i><sup>13</sup>C, CO<sub>2</sub> concentration, and CO<sub>2</sub>∕SO<sub>2</sub> in volcanic plume gases at Mount Etna, Italy, over 5 consecutive days,
Chem. Geol.,
411, 182–191, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Roberts, T. J., Martin, R. S., and Jourdain, L.: Reactive bromine chemistry in Mount Etna's volcanic plume: the influence of total Br, high-temperature processing, aerosol loading and plume–air mixing, Atmos. Chem. Phys., 14, 11201–11219, <a href="https://doi.org/10.5194/acp-14-11201-2014" target="_blank">https://doi.org/10.5194/acp-14-11201-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Roberts, T. J., Lurton, T., Giudice, G., Liuzzo, M., Aiuppa, A., Coltelli, M., Vignelles, D., Salerno, G., Couté, B., Chartier, M., Baron, R., Saffell, J. R., and Scaillet, B.:
Validation of a novel Multi-Gas sensor for volcanic HCl alongside H<sub>2</sub>S and SO<sub>2</sub> at Mt. Etna,
B. Volcanol.,
79, 11201–11219, <a href="https://doi.org/10.1007/s00445-017-1114-z" target="_blank">https://doi.org/10.1007/s00445-017-1114-z</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Rüdiger, J., Bobrowski, N., Liotta, M., and Hoffmann, T.:
Development and application of a sampling method for the determination of reactive halogen species in volcanic gas emissions,
Anal. Bioanal. Chem.,
409, 5975–5985, <a href="https://doi.org/10.1007/s00216-017-0525-1" target="_blank">https://doi.org/10.1007/s00216-017-0525-1</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
Rüdiger, J., Tirpitz, J.-L., de Moor, J. M., Bobrowski, N., Gutmann, A., Liuzzo, M., Ibarra, M., and Hoffmann, T.: Implementation of electrochemical, optical and denuder-based sensors and sampling techniques on UAV for volcanic gas measurements: examples from Masaya, Turrialba and Stromboli volcanoes, Atmos. Meas. Tech., 11, 2441–2457, <a href="https://doi.org/10.5194/amt-11-2441-2018" target="_blank">https://doi.org/10.5194/amt-11-2441-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Rüdiger, J., Gutmann, A., Bobrowski, N., Liotta, M., de Moor, J. M., Sander, R., Dinger, F., Tirpitz, J.-L., Ibarra, M., Saballos, A., Martínez, M., Mendoza, E., Ferrufino, A., Stix, J., Valdés, J., Castro, J. M., and Hoffmann, T.: Halogen activation in the plume of Masaya volcano: field observations and box model investigations, Atmos. Chem. Phys., 21, 3371–3393, <a href="https://doi.org/10.5194/acp-21-3371-2021" target="_blank">https://doi.org/10.5194/acp-21-3371-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Ryan, W. B. F., Carbotte, S. M., Coplan, J. O., O'Hara, S., Melkonian, A., Arko, R., Weissel, R. A., Ferrini, V., Goodwillie, A., Nitsche, F., Bonczkowski, J., and Zemsky, R.:
Global Multi-Resolution Topography synthesis,
Geochem. Geophy. Geosy.,
10, Q03014, <a href="https://doi.org/10.1029/2008GC002332" target="_blank">https://doi.org/10.1029/2008GC002332</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
Sano, Y. and Marty, B.:
Origin of carbon in fumarolic gas from island arcs,
Chem. Geol.,
119, 265–274, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Sano, Y. and Williams, S. N.:
Fluxes of mantle and subducted carbon along convergent plate boundaries,
Geophys. Res. Lett.,
23, 2749–2752, <a href="https://doi.org/10.1029/96GL02260" target="_blank">https://doi.org/10.1029/96GL02260</a>, 1996.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation>
Schellenberg, B., Richardson, T., Watson, M., Greatwood, C., Clarke, R., Thomas, R., Wood, K., Freer, J., Thomas, H., Liu, E., Salama, F., and Chigna, G.:
Remote sensing and identification of volcanic plumes using fixed-wing UAVs over Volcán de Fuego, Guatemala,
J. Field Robot., 36, 1192—1211,
<a href="https://doi.org/10.1002/rob.21896" target="_blank">https://doi.org/10.1002/rob.21896</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation>
Sharp, Z. D.:
Principles of Stable Isoptope Geochemistry,
Pearson Prentice Hall, New Jersey, 344 pp., 2007.

</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation>
Shinohara, H.:
A new technique to estimate volcanic gas composition: plume measurements with a portable multi-sensor system,
J. Volcanol. Geoth. Res.,
143, 319–333, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation>
Stix, J., de Moor, J. M., Rüdiger, J., Alan, A., Corrales, E., D'Arcy, F., Diaz, J. A., and Liotta, M.:
Using Drones and Miniaturized Instrumentation to Study Degassing at Turrialba and Masaya Volcanoes, Central America,
J. Geophys. Res.-Sol. Ea.,
123, 6501–6520, <a href="https://doi.org/10.1029/2018jb015655" target="_blank">https://doi.org/10.1029/2018jb015655</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation>
Stoiber, R., Malinconico Jr., L., Williams, S. N.:
Use of the correlation spectrometer at volcanoes,
in: Forecasting Volcanic Events. Developments in Volcanology,
edited by: Tazieff, H. and Sabroux, J. C.,
Elsevier Science Publisher, Amsterdam, the Netherlands, 425-444, 1983.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation>
Syahbana, D. K., Kasbani, K., Suantika, G., Prambada, O., Andreas, A. S., Saing, U. B., Kunrat, S. L., Andreastuti, S., Martanto, M., Kriswati, E., Suparman, Y., Humaida, H., Ogburn, S., Kelly, P. J., Wellik, J., Wright, H. M. N., Pesicek, J. D., Wessels, R., Kern, C., Lisowski, M., Diefenbach, A., Poland, M., Beauducel, F., Pallister, J., Vaughan, R. G., and Lowenstern, J. B.:
The 2017–19 activity at Mount Agung in Bali (Indonesia): Intense unrest, monitoring, crisis response, evacuation, and eruption,
Sci. Rep.,
9, 8848, <a href="https://doi.org/10.1038/s41598-019-45295-9" target="_blank">https://doi.org/10.1038/s41598-019-45295-9</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation>
Textor, C., Graf, H.-F., Timmreck, C., and Robock, A. (Eds.):
Emissions from volcanoes: Emissions of Atmospheric Trace Compounds, Advances in Global Change Research, 18,
Springer Netherlands, Dordrecht, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation>
Vandaele, A. C., Simon, P. C., Guilmot, J. M., Carleer, M., and Colin, R.:
SO<sub>2</sub> Absorption cross-section measurement in the UV using a Fourier transform spectrometer,
J. Geophys. Res.,
99, 25599–25605, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation>
van Geldern, R., Nowak, M. E., Zimmer, M., Szizybalski, A., Myrttinen, A., Barth, J. A., and Jost, H. J.:
Field-based stable isotope analysis of carbon dioxide by mid-infrared laser spectroscopy for carbon capture and storage monitoring,
Anal. Chem.,
86, 12191–12198, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation>
Venzke, E. (Ed.):
Volcanoes of the World v. 4.8.3., Global_Volcanism_Program, Manam (251020),
Smithsonian Institution, <a href="https://doi.org/10.5479/si.GVP.VOTW4-2013" target="_blank">https://doi.org/10.5479/si.GVP.VOTW4-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>58</label><mixed-citation>
Villa, T. F., Gonzalez, F., Miljievic, B., Ristovski, Z. D., and Morawska, L:
An Overview of Small Unmanned Aerial Vehicles for Air Quality Measurements: Present Applications and Future Prospectives,
Sensors, 16, 1072, <a href="https://doi.org/10.3390/s16071072" target="_blank">https://doi.org/10.3390/s16071072</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib59"><label>59</label><mixed-citation>
Voigt, S., Orphal, J., Bogumil, K., and Burrows, J. P.:
The temperature dependence (203–293&thinsp;K) of the absorption cross sections of O<sub>3</sub> in the 230–850&thinsp;nm region measured by Fourier-Transform spectroscopy,
J. Photoch. Photobio. A,
143, 1–9, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib60"><label>60</label><mixed-citation>
Wagner, W. and Pruß, A.:
The IAPWS Formulation 1995 for the Thermodynamic Properties of Ordinary Water Substance for General and Scientific Use,
J. Phys. Chem. Ref. Data,
31, 387–535, 2002.
</mixed-citation></ref-html>--></article>