<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-14-5349-2021</article-id><title-group><article-title>Measurements of CFC-11, CFC-12, and HCFC-22 total columns in the atmosphere at the St. Petersburg site in 2009–2019</article-title><alt-title>Measurements of CFC-11, CFC-12, and HCFC-22 atmospheric content</alt-title>
      </title-group><?xmltex \runningtitle{Measurements of CFC-11, CFC-12, and HCFC-22 atmospheric content}?><?xmltex \runningauthor{A. Polyakov et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name><surname>Polyakov</surname><given-names>Alexander</given-names></name>
          <email>a.v.polyakov@spbu.ru</email>
        <ext-link>https://orcid.org/0000-0002-7406-8986</ext-link></contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Poberovsky</surname><given-names>Anatoly</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Makarova</surname><given-names>Maria</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2469-9250</ext-link></contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Virolainen</surname><given-names>Yana</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-5674-2391</ext-link></contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Timofeyev</surname><given-names>Yuri</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2771-9931</ext-link></contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Nikulina</surname><given-names>Anastasiia</given-names></name>
          
        </contrib>
        <aff id="aff1"><institution>Department of Atmospheric Physics, St. Petersburg State University, 7–9 Universitetskaya Emb.,<?xmltex \hack{\break}?> St. Petersburg 199034, Russia</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Alexander Polyakov (a.v.polyakov@spbu.ru)</corresp></author-notes><pub-date><day>4</day><month>August</month><year>2021</year></pub-date>
      
      <volume>14</volume>
      <issue>8</issue>
      <fpage>5349</fpage><lpage>5368</lpage>
      <history>
        <date date-type="received"><day>28</day><month>August</month><year>2020</year></date>
           <date date-type="rev-request"><day>17</day><month>October</month><year>2020</year></date>
           <date date-type="rev-recd"><day>1</day><month>June</month><year>2021</year></date>
           <date date-type="accepted"><day>5</day><month>July</month><year>2021</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2021 Alexander Polyakov et al.</copyright-statement>
        <copyright-year>2021</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021.html">This article is available from https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e126">Monitoring atmospheric anthropogenic halocarbons plays an important role in tracking their atmospheric concentrations in accordance with international agreements on emissions of ozone-depleting substances and, thus, in estimating the ozone layer recovery.</p>
    <p id="d1e129">Within the Network for the Detection of Atmospheric Composition Change (NDACC), regular Fourier transform infrared (FTIR) measurements can provide information on the abundancies of halocarbons on a global scale. We improved retrieval strategies for deriving the CFC-11 (<inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CCl</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mi mathvariant="normal">F</mml:mi></mml:mrow></mml:math></inline-formula>), CFC-12 (<inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CCl</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">F</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), and HCFC-22 (<inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CHClF</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) atmospheric columns from IR solar radiation spectra measured by the Bruker IFS125HR spectrometer at the St. Petersburg site (Russia). We used the Tikhonov–Phillips regularization approach for solving the inverse problem with optimized values of regularization parameters. We tested the strategies developed by comparison of the FTIR measurements with independent data. The analysis of the time series of column-averaged dry air mole fractions (Xgas) measured in 2009–2019 gives mean values of 225 pptv (parts per trillion by volume; CFC-11), 493 pptv (CFC-12), and 238 pptv (HCFC-22). Trend values total <inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M5" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (CFC-11), <inline-formula><mml:math id="M6" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M7" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (CFC-12), and 2.12 % yr<inline-formula><mml:math id="M8" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (HCFC-22).</p>
    <p id="d1e229">We compared the means, trends, and seasonal variability in <inline-formula><mml:math id="M9" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> to that of (1) near-ground volume mixing ratios (VMRs), measured at the observational site Mace Head, Ireland (GVMR), (2) the mean in the 8–12 km layer VMRs, measured by ACE-FTS and averaged over 55–65<inline-formula><mml:math id="M12" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N latitudes (SVMR), and (3) Xgas values of the Whole Atmosphere Community Climate Model (WACCM) for the St. Petersburg site (WXgas).</p>
    <p id="d1e289">In general, the comparison of Xgas with the independent data showed a good agreement of their means within the systematic errors of the measurements
considered. The trends observed over the St. Petersburg site demonstrate the smaller decrease rates for <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> than that of the independent data and the same increase rate for <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>. As a whole, Xgas, SVMR, and WXgas showed qualitatively similar seasonal variations, while the GVMR variability is significantly less, and only the <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> variations are essentially smaller than that of <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SVMR</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e398">Since the middle of the 20th century, anthropogenic trace gases, the molecules of which contain halogens, due to their specific physical and chemical properties, have been actively used in the climatic and refrigeration industry, as well as in various propellants. <xref ref-type="bibr" rid="bib1.bibx29" id="text.1"/> have shown that these gases play an important role in the destruction of stratospheric ozone. In particular, the photolysis of <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CCl</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mi mathvariant="normal">F</mml:mi></mml:mrow></mml:math></inline-formula> (trichlorofluoromethane; CFC-11) and <inline-formula><mml:math id="M20" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CCl</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">F</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (dichlorodifluoromethane; CFC-12) in the stratosphere leads to the appearance of active chlorine, which is involved in ozone depletion reactions.
The <xref ref-type="bibr" rid="bib1.bibx55" id="text.2"><named-content content-type="post">Appendix A</named-content></xref> estimates the ozone depletion potential (ODP)
of CFC-12 as being 0.73–0.81 (the ODP of CFC-11, chosen as a reference, equals 1). Although the major content of these gases is concentrated in the troposphere, in the equatorial region, the global circulation moves them out into the lower and middle stratosphere and transports them to high-latitude regions. In the<?pagebreak page5350?> stratosphere, chlorofluorocarbons (CFCs) are photochemically decomposed to chlorinated free radicals (<inline-formula><mml:math id="M21" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">Cl</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">ClO</mml:mi></mml:mrow></mml:math></inline-formula>) that are deactivated into chlorine reservoirs of <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HCl</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">ClONO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">HOCl</mml:mi></mml:mrow></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx54" id="paren.3"><named-content content-type="post">Chapter 3</named-content></xref>. In polar regions, heterogeneous reactions on the surfaces of polar stratospheric clouds and cold sulfate aerosols convert inert reservoir molecules into active forms that photolyze, producing free radicals, and cause the chemical ozone depletion in spring through catalytic cycles resulting up to the appearance of ozone holes <xref ref-type="bibr" rid="bib1.bibx48" id="paren.4"/>.</p>
      <p id="d1e490">As the result of the Montreal Protocol and its amendments and adjustments that restricted the production of CFCs <xref ref-type="bibr" rid="bib1.bibx55" id="paren.5"><named-content content-type="pre">see</named-content></xref>, the industry moved away from CFCs to less ozone-depleting hydrochlorofluorocarbons (HCFCs), especially <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CHClF</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (chlorodifluoromethane; HCFC-22). Although the ODP of HCFC-22 is much lower than that of CFCs, it is an ozone-depleting substance too. Ozone depletion by HCFC-22 is primarily associated with the heating of the stratosphere, and its ODP, although small, totals 0.024–0.34.</p>
      <p id="d1e509">CFC-11 and CFC-12, like HCFC-22, also absorb infrared radiation; therefore,
they are all greenhouse gases. The global warming potential (GWP) represents the integrated radiative forcing (RF) for a conditional time horizon (20, 100, and 500 years) caused by emissions of a unit mass of a gas relative to the same RF value of <inline-formula><mml:math id="M27" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> that is chosen as a reference for estimating the GWP of other gases. According to <xref ref-type="bibr" rid="bib1.bibx55" id="text.6"><named-content content-type="post">Appendix A</named-content></xref>, the GWP for 100 years is 5160 for CFC-11, 10 300 for CFC-12, and 1780 for HCFC-22.
One of the reasons for the high GWP values of these gases is their long
lifetimes, i.e., 52, 102, and 11.9 years, respectively. Due to their long lifetimes, these gases are also good indicators for studying the transport and mixing processes in the upper troposphere and the lower stratosphere <xref ref-type="bibr" rid="bib1.bibx14" id="paren.7"><named-content content-type="pre">e.g.,</named-content></xref>.</p>
      <p id="d1e533">After <xref ref-type="bibr" rid="bib1.bibx29" id="text.8"/> reported that the CFCs accumulating in the Earth's
atmosphere led to an increased rate of ozone depletion, the attention of both
scientists and policymakers to the ozone hole problem increased. Nowadays,  monitoring of ozone and other stratospheric gases, as well as ozone-depleting substances, including CFCs, is crucial for testing the theories of the ozone hole formation mechanism <xref ref-type="bibr" rid="bib1.bibx7" id="paren.9"/>.</p>
      <p id="d1e543">The Montreal Protocol from 1987, which came into force in 1989, limited the production and consumption of CFCs. Later on, in 1992, in Copenhagen, and
in 1995, in Vienna, the phasing out of CFCs was started by the end of 1995 in
developed countries and by the end of 2010 in developing countries. Therefore, the atmospheric burden of CFC-11 and CFC-12 was declining at an average rate of 0.7 % yr<inline-formula><mml:math id="M28" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>–1.2 % yr<inline-formula><mml:math id="M29" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and 0.4 % yr<inline-formula><mml:math id="M30" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>–0.5 % yr<inline-formula><mml:math id="M31" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, respectively <xref ref-type="bibr" rid="bib1.bibx6" id="paren.10"/>.
ACE-FTS (Atmospheric Chemistry Experiment and Fourier transform spectrometer)  satellite measurements in the last 16 years <xref ref-type="bibr" rid="bib1.bibx2" id="paren.11"/> have illustrated the success of the Montreal Protocol by demonstrating decreasing trends in CFC-11 (<inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.53</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M33" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) and CFC-12 (<inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.61</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M35" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) abundancies and a slowing rate of increase in HCFC-22 abundancies (1.8 % yr<inline-formula><mml:math id="M36" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). ACE-FTS estimates are made for latitudes between 60<inline-formula><mml:math id="M37" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> S and 60<inline-formula><mml:math id="M38" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N and for altitudes between 5.5 and 10.5 km. Nevertheless, with its accumulation in the troposphere, CFC-11 still provides a quarter of all chlorine reaching the stratosphere.
The time needed for recovery of the ozone layer depends, among other factors, on the sustainability of the reduction in the atmospheric concentrations of CFC-11, CFC-12, and other halocarbons.</p>
      <p id="d1e676">Based on the 2015–2017 data, <xref ref-type="bibr" rid="bib1.bibx31" id="text.12"/> showed that the rate of
change in the CFC-11 atmospheric concentrations decreased by approximately half to <inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:mi mathvariant="normal">−</mml:mi><mml:mn mathvariant="normal">0.4</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M40" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, assuming that this slowdown is caused by the emergence of new, unregistered sources. This finding enhances the importance of the CFC-11 monitoring. The maximum of the CFC-12 atmospheric concentrations was observed in the early 2000s; since then, its steady decrease has been detected with an average rate of 0.4 % yr<inline-formula><mml:math id="M41" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> to 0.5 % yr<inline-formula><mml:math id="M42" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Advanced Global Atmospheric Gases Experiment (AGAGE)  network;
<uri>http://agage.mit.edu/data/agage-data</uri>, last access: 3 August 2020). As HCFCs are “transitional substances” for the replacement of CFCs, their production has increased rapidly in developed countries in the 1990s and peaked in the mid-1990s. Under the Montreal Amendment (1997), all countries must gradually phase down HCFCs.
In September 2007, it was decided to accelerate the phasing out of HCFCs.
Developed countries were reducing their consumption of HCFCs and completely phased them out by 2020. Developing countries agreed to start their phase-out process in 2013 and are now following a stepwise reduction until the complete phase out of HCFCs by 2030.</p>
      <p id="d1e732">On a global scale, two data sources are mainly used to study the trends and
seasonal variations in the target gases, i.e., local measurements of near-ground
concentrations (e.g., the AGAGE networks, <xref ref-type="bibr" rid="bib1.bibx8" id="altparen.13"/>, NOAA's
Halocarbons &amp; other Atmospheric Trace Species (HATS) and Chlorofluorocarbon Alternatives Monitoring Project (CAMP),
<xref ref-type="bibr" rid="bib1.bibx30" id="altparen.14"/>), and satellite limb measurements by the Improved Limb Atmospheric Spectrometer (ILAS), ACE-FTS, and Michelson Interferometer for Passive Atmospheric Sounding <xref ref-type="bibr" rid="bib1.bibx15 bib1.bibx22 bib1.bibx9 bib1.bibx18 bib1.bibx5" id="paren.15"><named-content content-type="pre">MIPAS;</named-content></xref>. In contrast to satellite and in situ measurements near ground, ground-based
Fourier transform infrared (FTIR)  measurements of solar radiation are
sensitive to changes in total columns (TCs) of atmospheric gases.
The FTIR method complements the information obtained by the first two methods, although it does not allow detailed information on the vertical gas
distribution to be retrieved.</p>
      <p id="d1e746">The first FTIR measurements of atmospheric HCFC-22 were performed from the balloon in early 1980s <xref ref-type="bibr" rid="bib1.bibx12" id="paren.16"/>. Later, with the appearance of high-resolution instruments, halocarbons started to be derived with ground-based FTIR spectrometers. In the last few<?pagebreak page5351?> decades, TCs of halocarbons are more actively measured by ground-based FTIR methods <xref ref-type="bibr" rid="bib1.bibx33 bib1.bibx42 bib1.bibx43 bib1.bibx57 bib1.bibx24 bib1.bibx21 bib1.bibx23 bib1.bibx58 bib1.bibx41" id="paren.17"><named-content content-type="pre">e.g.,</named-content></xref>. Time series of CFC-11, CFC-12, and HCFC-22 TCs above the Jungfraujoch station, Switzerland, are presented in World Meteorological Organization (WMO) reports on the scientific assessment of ozone depletion <xref ref-type="bibr" rid="bib1.bibx55" id="paren.18"><named-content content-type="pre">e.g.,</named-content></xref>.</p>
      <p id="d1e762">Within the Network for the Detection of Atmospheric Composition Change (NDACC; <uri>http://www.ndaccdemo.org/</uri>, last access: 28 July 2021), regular FTIR measurements provide information on TCs of a number of atmospheric trace gases, including halocarbons, with a large spatial coverage (at 19 out of 77 network stations located at latitudes between 78<inline-formula><mml:math id="M43" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> S and 80<inline-formula><mml:math id="M44" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N). <xref ref-type="bibr" rid="bib1.bibx23" id="text.19"/> reported on the results of R-142b measurements, along with the comparison with independent data and the trend estimates. <xref ref-type="bibr" rid="bib1.bibx58" id="text.20"/> showed the results of CFC-11, CFC-12, and HCFC-22 measurements at two NDACC sites on Réunion island for the period of 2004–2016, including the trend estimates and the comparison with the satellite data. <xref ref-type="bibr" rid="bib1.bibx41" id="text.21"/> proposed a technique for estimating two partial columns and TCs of HCFC-22 at the Jungfraujoch mountain station and a corresponding time series of HCFC-22 TCs for 1988–2017, along with a trend analysis for various time periods.</p>
      <p id="d1e796">The archive of ground-based spectroscopic measurements of IR solar radiation,
performed at the NDACC site of St. Petersburg <xref ref-type="bibr" rid="bib1.bibx51 bib1.bibx53" id="paren.22"/> since 2009, has been used to derive TCs of CFC-11, CFC-12, and HCFC-22. First, in Russia, estimates of CFC-11 TCs using the FTIR method and the original retrieval technique were given by <xref ref-type="bibr" rid="bib1.bibx56" id="text.23"/>. <xref ref-type="bibr" rid="bib1.bibx37" id="text.24"/> presented the preliminary results of CFC-11, CFC-12, and HCFC-22 TCs retrieval for the period of 2009–2016, using the SFIT4 software (version 0.9.4.4) described by <xref ref-type="bibr" rid="bib1.bibx13" id="text.25"/>.
It should be noted that the SFIT4 software is a versatile tool, and it is
necessary to customize it for a specific task through the selection and tuning of numerous parameters. <xref ref-type="bibr" rid="bib1.bibx37" id="text.26"/> selected these parameters, based on the studies at other NDACC sites <xref ref-type="bibr" rid="bib1.bibx24 bib1.bibx58" id="paren.27"/>, and the general recommendations of the IR working group (IRWG) of the NDACC network. However, these first results raised a several problems; in  particular, there was an unreasonably large scatter of the TC values and significant seasonal variations. A later study showed that the scatter and seasonal variability observed were not due to objective reasons but due to peculiarities in the processing retrieval technique.</p>
      <p id="d1e819">The information content of the FTIR spectra, with respect to target gases
abundancies, is not large, due to several reasons. First, the absorption of CFC-11 and HCFC-22 is not strong. Even for a solar elevation of about 15<inline-formula><mml:math id="M45" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>, the transmission of solar radiation caused by CFC-11 absorption is greater than 90 %, and for HCFC-22, it is close to 75 %. For a solar elevation of about 50<inline-formula><mml:math id="M46" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>, these values are estimated as being  96 % and 95 %, respectively. Second, there is the absorption of interfering gases in the spectral range considered. Thus, the CFC-11 absorption band overlaps with several strong water vapor absorption lines and the <inline-formula><mml:math id="M47" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">HNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption band, and each of the CFC-12 and HCFC-22 absorption bands overlap a wing of the water vapor absorption line (see Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>). Finally, the CFC-12 and, to a larger extent, the CFC-11 bands have a smoothed spectral dependency of absorption that requires the use of wide microwindows for retrieving their abundancies, i.e., 2 cm<inline-formula><mml:math id="M48" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for CFC-12 and not smaller than 30 cm<inline-formula><mml:math id="M49" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for CFC-11. These factors cause difficulties in halocarbon retrieval from FTIR spectra measurements.</p>
      <p id="d1e878">Later, the retrieval techniques for estimating CFC-11, CFC-12, and HCFC-22 TCs by the FTIR method at the St. Petersburg site were refined and improved.
These techniques were described in detail by <xref ref-type="bibr" rid="bib1.bibx38 bib1.bibx39 bib1.bibx40" id="text.28"/>. In the current study, we present the main features of the techniques developed and analyzed using the Tikhonov–Phillips (<inline-formula><mml:math id="M50" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula>) approach. The time series of CFC-11, CFC-12, and HCFC-22 TCs were extended until the fall of 2019. The time series of the TCs were analyzed and compared to independent measurements and numerical modeling data.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Technique for inverting the spectroscopic measurements</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Spectroscopic measurements</title>
      <p id="d1e911">The main features of the ground-based station, observational system, and the
technique for measuring the solar spectra used in this study were described in detail by <xref ref-type="bibr" rid="bib1.bibx51" id="text.29"/>.</p>
      <p id="d1e917">The St. Petersburg site is located in Peterhof, 30 km west of the city of
St. Petersburg. The latitude of the site (59.88<inline-formula><mml:math id="M51" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N) predetermines winter measurements with a low solar elevation; in December–January, the maximal solar elevation does not usually exceed 20<inline-formula><mml:math id="M52" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>, and spectroscopic measurements are performed up to a solar elevation of 5<inline-formula><mml:math id="M53" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>. Due to peculiarities of the local weather, measurements are mainly (76 %) carried out in the spring and summer seasons. The spectra analyzed are obtained without any additional apodization of the interferograms, and their spectral resolution is 0.005 cm<inline-formula><mml:math id="M54" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. The observational system is based on a Bruker IFS125HR Fourier spectrometer, but
some of the equipment is nonstandard. Before February 2016, a nonstandard (for the IRWG-NDACC sites) spectral filter (hereinafter F3) was used for measurements in a spectral region with the absorption bands of the target gases. Since this filter was plane-parallel, a parasitic interference arose in it, leading to the appearance of an effect of the optical resonance <xref ref-type="bibr" rid="bib1.bibx4" id="text.30"><named-content content-type="pre">“channeling”; see</named-content></xref>. In addition, a homemade solar tracking system is used.</p>
      <?pagebreak page5352?><p id="d1e964"><?xmltex \hack{\newpage}?>The period of channeling is caused by the material and the thickness of the
filter, and in the spectral region (800–900 cm<inline-formula><mml:math id="M55" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), it is close to 1.1 cm<inline-formula><mml:math id="M56" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, while the channeling amplitude varies from zero to a few percent, depending randomly on the filter positioning. To analyze the presence and the channeling amplitude, we performed the Fourier analysis in the most transparent spectral range (892–905 cm<inline-formula><mml:math id="M57" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) for harmonic components, with interval periods of 1–1.25 cm<inline-formula><mml:math id="M58" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. The channeling amplitude was calculated relative to the mean signal value in this spectral range.</p>
      <p id="d1e1016">The SFIT4 software supports the accounting for channeling, and its compensation is in a spectrum. Before September 2009, some of the spectra measured had significant values of the channeling amplitude. We excluded spectra with a channeling amplitude that exceeds 2 % from further processing, assuming that such a distortion of the spectra is too great. Afterwards, the filter was installed so as to minimize channeling. In addition, we analyzed the autocorrelation coefficient of a dark noise in the range of 660–680 cm<inline-formula><mml:math id="M59" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (except for a slope) and excluded the spectra with an averaged autocorrelation coefficient greater than 0.1. A large autocorrelation coefficient of the dark noise indicates the presence of
external influences on a measurement process. Moreover, we excluded the spectra that were measured when a haze or clouds were observed in any part of the sky from further processing, since the use of these spectra also noticeably increases the scatter of the results.</p>
      <p id="d1e1032">As a result of the filtering described, 2901 of 3523 (i.e., 82 %) spectra measured before February 2016 were selected for further processing.
In February 2016, the F3 filter was replaced by the standard IRWG NDACC
filter, f6, which eliminates the channeling through its wedge-shaped design. Thus, the quality of the measurements was improved, and 1903 of 1958 spectra
were selected, giving a sum of 4804 spectra for the 2009–2019 period.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Main parameters of the retrieval technique</title>
      <p id="d1e1043">In previous studies, <xref ref-type="bibr" rid="bib1.bibx38 bib1.bibx39 bib1.bibx40" id="text.31"/>
determined a number of parameters of the retrieval strategy using the SFIT4 code for deriving the TCs of the target gases from the FTIR measurements at the St. Petersburg site, i.e., boundaries of microwindows, mean (a priori) of the measured gases, the magnitude of and variability in the zero level, periods for taking into account (or excluding) channeling, and the background shape of a spectrum (BSS).</p>
      <p id="d1e1049">The criteria used for the optimization of retrieval parameters are briefly described below. As the lifetime of the target gases in the atmosphere is more than 10 years, and CFC-11 and CFC-12 have no known active sources of emission, we expect the stability of their retrieved columns, both during each day and during the whole period of measurements (excluding the trend). To a lesser extent, due to its continuous production, the same criterion is valid for HCFC-22, at least for intraday variability. Thus, <xref ref-type="bibr" rid="bib1.bibx38 bib1.bibx39 bib1.bibx40" id="text.32"/> used the stability of retrieved total columns in terms of the minimal root mean squared (RMS) standard deviation (SD) of the TCs for all days of measurements as the main criterion in choosing the retrieval parameters. Another important retrieval parameter is the number of degrees of freedom for signal (DFS) <xref ref-type="bibr" rid="bib1.bibx44" id="paren.33"><named-content content-type="post">p. 19</named-content></xref> for target gases. As a criterion for optimization, the SD of the DFS is minimized. Estimates of total systematic and random measurement errors are also considered. Finally, the spectral residuals (differences between spectra measured and calculated with the retrieved atmospheric state) are analyzed. To estimate the residuals in the SFIT4 software, spectra are normalized to the unit, and RMS difference is calculated and denoted as <inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e1071">It should be noted that, without additional analysis, the listed criteria
do not unambiguously determine the optimal retrieval technique. Thus, for example, by adding an unknown parameter, such as channeling, to the spectra analysis, we increase the measurements errors; however, if we remove it, and residuals become larger, it will indicate that the parameters used are inadequate for real measurements, i.e., the actual presence of channeling in the spectra. Table <xref ref-type="table" rid="Ch1.T1"/> highlights the main parameters optimized in previous studies.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e1080">The main parameters of the inversion of the spectra for deriving
the TCs of halocarbons obtained by <xref ref-type="bibr" rid="bib1.bibx38 bib1.bibx39 bib1.bibx40" id="text.34"/>.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Gas</oasis:entry>
         <oasis:entry colname="col2">Microwindow,</oasis:entry>
         <oasis:entry colname="col3">Other gases</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M61" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> spectroscopy</oasis:entry>
         <oasis:entry colname="col5">Accounting for channeling</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">cm<inline-formula><mml:math id="M62" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5">(beam)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">CFC-11</oasis:entry>
         <oasis:entry colname="col2">830–860</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M63" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> (profile), <inline-formula><mml:math id="M64" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M65" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M66" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">HNO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">COCl</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (columns)</oasis:entry>
         <oasis:entry colname="col4">HITRAN 2016</oasis:entry>
         <oasis:entry colname="col5">1.12 cm<inline-formula><mml:math id="M68" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> before 2016</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CFC-12</oasis:entry>
         <oasis:entry colname="col2">1160–1162</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M69" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M70" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M72" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (columns)</oasis:entry>
         <oasis:entry colname="col4">HITRAN 2009</oasis:entry>
         <oasis:entry colname="col5">1.26 cm<inline-formula><mml:math id="M73" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> before 2016</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">HCFC-22</oasis:entry>
         <oasis:entry colname="col2">828.75–829.4</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M74" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M75" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M76" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> (columns)</oasis:entry>
         <oasis:entry colname="col4">HITRAN 2009</oasis:entry>
         <oasis:entry colname="col5">1.1 cm<inline-formula><mml:math id="M77" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> before 2016</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1391">While processing the measured spectra, spectroscopic parameters supplied as
a part of the SFIT4 software are used. Target gases and <inline-formula><mml:math id="M78" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">COCl</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> absorption is calculated based on pseudo-lines (see <uri>https://mark4sun.jpl.nasa.gov/pseudo.html</uri>, last access: 3 July 2019); other interfering gases absorption is calculated based on spectroscopic information from HITRAN (high-resolution transmission molecular absorption database). The a priori information on the physical state of the atmosphere is taken from the NCEP CPC (National Centers for Environmental Prediction Climate Prediction Center; <uri>ftp://ftp.cpc.ncep.noaa.gov/ndacc/ncep/</uri>, last access: 1 May 2021); water vapor profiles used in the retrieval are independently derived from the FTIR measurements as per the technique described by <xref ref-type="bibr" rid="bib1.bibx53" id="text.35"/>. The a priori profiles of other interfering gases are taken from the Whole Atmosphere Community Climate Model <xref ref-type="bibr" rid="bib1.bibx34" id="paren.36"><named-content content-type="pre">WACCM</named-content></xref>. As a first guess for target gases, the mean profiles of the WACCM data set for the 2009–2019 period are used. A wide spectral window for CFC-11 retrieval (30 cm<inline-formula><mml:math id="M79" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; see Table <xref ref-type="table" rid="Ch1.T1"/>) is unusual for deriving the
information on the gas content from high-resolution IR spectra and requires
a nonstandard approach for considering the BSS. This approach was described in detail by <xref ref-type="bibr" rid="bib1.bibx40" id="text.37"/>; the main features of this approach are listed below.</p>
      <p id="d1e1437">The filter spectral transmission function (STF) is a constant and important
factor that determines the BSS. We have measured the STF in a special experiment using an artificial source of light.</p>
      <p id="d1e1440">Repeated measurements of the STF showed that, over time, they exhibit a specific spectrum of absorption by amorphous water ice  (AWI), which is formed on the HgCdTe<?pagebreak page5353?> (mercury cadmium telluride, MCT) detector at temperatures are cooled by liquid nitrogen <xref ref-type="bibr" rid="bib1.bibx16 bib1.bibx20" id="paren.38"><named-content content-type="pre">e.g.,</named-content></xref>. Absorption of radiation by AWI depends on its thickness, which increases during the measurement period and decreases during the period of inactivity of the instrument when the detector is not cooled. In addition, the water vapor from the atmospheric air gradually (on a monthly scale) seeps into the evacuated zone of the instrument and also leads to an increase in the AWI thickness. To compensate for the BSS curvature due to the AWI thickness, we use a second-degree polynomial implemented in the SFIT4 code. To account for the variability in the AWI thickness, we turn on the coefficient at the quadratic term of the polynomial (hereinafter, curvature value) and limit its a priori variability to avoid the “over-freedom” of the solution. We minimized the intraday variability in CFC-11 TCs in a series of spectra processing and, in the first step, obtained the a priori thickness of the AWI (0.3 <inline-formula><mml:math id="M80" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> for F3; 0.9 <inline-formula><mml:math id="M81" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> for f6) with the a priori curvature value of zero.
In the next step, we optimized the value of a priori curvature uncertainty as
<inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for both filters.</p>
      <p id="d1e1482">The water vapor continuum makes a significant contribution to radiation  attenuation by the atmospheric water vapor <xref ref-type="bibr" rid="bib1.bibx28" id="paren.39"/>. Our calculations have shown that radiation absorption by the water vapor continuum in the considered spectral region under conditions at the St. Petersburg site can significantly exceed 50 %. For a 30 cm<inline-formula><mml:math id="M83" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> window, the selectivity of the continual uptake is sufficient to influence the spectra-processing results. To calculate the water vapor continuum, we use a freely distributed computer code <xref ref-type="bibr" rid="bib1.bibx1" id="paren.40"/> and the daily profiles of water vapor independently derived from the FTIR measurements <xref ref-type="bibr" rid="bib1.bibx53" id="paren.41"/>. The code <xref ref-type="bibr" rid="bib1.bibx1" id="paren.42"/> calculates the spectral  dependence of the continuum absorption of radiation by a homogeneous layer of the atmosphere. We used this code to integrate the optical thickness of all atmospheric layers, based on the same profiles of pressure and temperature
that were used in SFIT4. As a first approximation, the contribution of the water vapor continuum to absorption is proportional to the water vapor partial pressure squared, and it can only be detected in a very humid atmosphere. We estimated the contribution of the water vapor continuum numerically by analyzing spectra with and without considering the spectra measured in 2018. Figure <xref ref-type="fig" rid="Ch1.F1"/> depicts a dependence of differences in CFC-11 TCs on water vapor TCs with and without considering the water vapor continuum. This dependence may misinterpret, for example, the results of the analysis of CFC-11 seasonal variations (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/>), the maximal amplitude of which does not exceed 3 %, while the maximal difference in TCs due to the water vapor continuum is close to <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.2</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">15</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math id="M85" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, which is more than 4 %.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e1544">A dependence of the differences in CFC-11 TCs, derived without and with taking the continuum on precipitable water during 2018 into account.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f01.png"/>

        </fig>

      <p id="d1e1553">Thus, for CFC-11 processing, we take into account the STF, AWI variability, and water vapor continuum. Figure <xref ref-type="fig" rid="Ch1.F2"/> highlights their contribution to the distortion in BSS. The expression for the monochromatic transmission function <inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:mi>P</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> can be written as Eq. (<xref ref-type="disp-formula" rid="Ch1.E1"/>), as follows:
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M87" display="block"><mml:mrow><mml:mi>P</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mi>exp⁡</mml:mi><mml:mo>(</mml:mo><mml:mo>-</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where, in the following:
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M88" display="block"><mml:mtable rowspacing="0.2ex" class="split" displaystyle="true" columnalign="right left"><mml:mtr><mml:mtd><mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mspace width="0.25em" linebreak="nobreak"/><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi mathvariant="normal">Filter</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi mathvariant="normal">Ice</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi mathvariant="normal">Cont</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi mathvariant="normal">OGases</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula></p>
      <p id="d1e1705">Terms correspond to contribution to optical depth by optical filter (IRWG NDACC f6), ice on the cooled detector, continuum attenuation, CFC-11, and other gases. Figure <xref ref-type="fig" rid="Ch1.F2"/> depicts the first four terms of the right-hand side of Eq. (<xref ref-type="disp-formula" rid="Ch1.E2"/>).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e1714">Nonlinearity of optical depth components <inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mn mathvariant="normal">830</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mn mathvariant="normal">860</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mn mathvariant="normal">830</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">830</mml:mn><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:mn mathvariant="normal">30</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. As on 29 July 2018, where the solar zenith angle is <inline-formula><mml:math id="M90" display="inline"><mml:mn mathvariant="normal">60</mml:mn></mml:math></inline-formula><inline-formula><mml:math id="M91" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f02.png"/>

        </fig>

      <?pagebreak page5354?><p id="d1e1801">We may conclude that nonlinearities in the first three of them are too considerable to be taken into account when CFC-11 content is estimated from a spectrum.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Method for solving the inverse problem</title>
      <p id="d1e1812">For solving the inverse problem, we used the <inline-formula><mml:math id="M92" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> approach presented by
<xref ref-type="bibr" rid="bib1.bibx50" id="text.43"/> and <xref ref-type="bibr" rid="bib1.bibx35" id="text.44"/>. The use of the first-order <inline-formula><mml:math id="M93" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> regularization <xref ref-type="bibr" rid="bib1.bibx50" id="paren.45"/> for retrieving the TCs of trace gases is described in detail, for example, by <xref ref-type="bibr" rid="bib1.bibx49" id="text.46"/>.</p>
      <p id="d1e1852">For the optimization of the regularization parameter <inline-formula><mml:math id="M94" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>, we used a technique based on minimizing the intraday variability in TCs suggested by
<xref ref-type="bibr" rid="bib1.bibx49" id="text.47"/>. In addition, we analyzed the residuals <inline-formula><mml:math id="M95" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and values of DFS. For the analysis of the regularization parameter, we used spectroscopic measurements from 2017, which were characterized by a fairly stable quality of measurements, a low noise level, and a possibly more uniform distribution of measurements throughout the year, including the winter months. Additionally, the year 2017 was chosen due to the measurements with the f6 filter, which is used at other sites in the IRWG NDACC network. The year 2015 was chosen for testing the F3 filter; calculations demonstrated that values of <inline-formula><mml:math id="M96" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> that are optimal for the f6 filter in 2017 are also optimal for the F3 filter.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e1889">Dependence of the TCs intraday variability in the regularization
parameter <inline-formula><mml:math id="M97" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=210.550394pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f03.png"/>

        </fig>

      <p id="d1e1906">Figure <xref ref-type="fig" rid="Ch1.F3"/> depicts the RMS intraday variability in TCs of target gases as a function of <inline-formula><mml:math id="M98" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> for 2017. The presence of a pronounced minimum for CFC-12 is due to larger information content of the spectral measurements with respect to CFC-12 abundancies compared to CFC-11 and HCFC-22 (DFS is 1.2 for CFC-12, 1.05 for CFC-11, and 1.0 for HCFC-22; see Table <xref ref-type="table" rid="Ch1.T3"/>). The reason for this is a weak absorption of interfering gases in the spectral range for CFC-12 retrievals. Thus, for CFC-12, an increase in the regularization parameter, which tightens the requirement for spectrum smoothness, leads to the suppression of useful information on the gas vertical structure contained in a spectrum. Consequently, the intraday variability in retrievals is increasing. For CFC-11 and HCFC-22, the information content of spectral measurements is less and DFS is close to 1; therefore, large values of the parameter <inline-formula><mml:math id="M99" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> and the corresponding requirements for smoothness do not contradict the information contained in a spectrum.</p>
      <p id="d1e1927">For CFC-11, the minimum of the intraday variability of 0.589 % is reached asymptotically for all values of <inline-formula><mml:math id="M100" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> not less than 85, and the DFS at <inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">85</mml:mn></mml:mrow></mml:math></inline-formula> differs from <inline-formula><mml:math id="M102" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> (<inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mtext>DFS</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.08</mml:mn></mml:mrow></mml:math></inline-formula>). For CFC-12, the optimal value of the regularization parameter <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">85</mml:mn></mml:mrow></mml:math></inline-formula>, this value corresponds to the intraday SD minimum of 0.382 %, and DFS totals 1.18. For HCFC-22, the minimum of intraday variability of 0.398 % is reached asymptotically for all values of <inline-formula><mml:math id="M105" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>, starting from <inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>, the DFS for all these values amounts to 1.00, and both parameters do not change for <inline-formula><mml:math id="M107" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> greater than <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>. This can be interpreted as a complete absence of the information on the vertical profile of HCFC-22 in spectral measurements; thus, we may obtain information on the first guess profile multiplier only (profile scaling approach).</p>
      <p id="d1e2025">Since DFS is close to unity for all three gases, we can consider a profile
scaling approach for solving the inverse problem. However, it turned out that, although the SFIT4 core solves the problem, a Python script for performing the batch processing and estimating errors does not work in this case. Moreover, if profile scaling is used for all gases considered (see Table <xref ref-type="table" rid="Ch1.T1"/>), then the mass processing is not performed. If at least one gas (i.e., <inline-formula><mml:math id="M109" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>) is retrieved as a profile, then mass processing is performed but error estimates are not calculated. We compared the two approaches by analyzing all spectra measured in 2018 (681 measurements over 80 d) for CFC-11 retrieval. The average difference between the TCs derived from profile scaling and <inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> approaches for this set of measurements is <inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.016</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">15</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math id="M112" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> or 0.33 %, and the SD of the difference is <inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.012</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">15</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math id="M114" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> or 0.26 %, which is significantly less than the measurement errors estimated. Therefore, to avoid problems with batch processing and error analysis, we chose the <inline-formula><mml:math id="M115" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> approach.</p>
      <?pagebreak page5355?><p id="d1e2122">Using the <inline-formula><mml:math id="M116" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> approach and choosing the regularization parameter based on minimizing the intraday variability of TCs, we obtained <inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:mtext>DFS</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> for HCFC-22; the DFS value of other two gases is close to 1 (1.05 and 1.20; see Table <xref ref-type="table" rid="Ch1.T3"/>). <xref ref-type="bibr" rid="bib1.bibx41" id="text.48"/> reported the higher values of DFS (<inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:mtext>DFS</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.97</mml:mn></mml:mrow></mml:math></inline-formula>) caused by <inline-formula><mml:math id="M119" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> regularization with the  parameter <inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:math></inline-formula> and a low atmospheric water vapor content above
the mountain (3580 m a.s.l.) site of Jungfraujoch.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and analysis</title>
      <p id="d1e2200">The techniques described above were applied to processing the entire archive of spectral measurements at the NDACC site of St. Petersburg for the period of 2009–2019.</p>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>The filtering of the results</title>
      <p id="d1e2210">Table <xref ref-type="table" rid="Ch1.T2"/> presents a number of statistical characteristics and the assessment of total errors for target gases.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e2218">Summary of the statistics for retrieved halocarbons TCs before filtering. The values after the “<inline-formula><mml:math id="M121" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>” sign indicate the standard deviation (SD). DFS is the number of degrees of freedom for signal.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">No.</oasis:entry>
         <oasis:entry colname="col2">Parameter</oasis:entry>
         <oasis:entry colname="col3">CFC-11</oasis:entry>
         <oasis:entry colname="col4">CFC-12</oasis:entry>
         <oasis:entry colname="col5">HCFC-22</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">No. of spectra/days</oasis:entry>
         <oasis:entry colname="col3">4773/720</oasis:entry>
         <oasis:entry colname="col4">4768/718</oasis:entry>
         <oasis:entry colname="col5">4585/714</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2</oasis:entry>
         <oasis:entry colname="col2">RMS (%)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.53</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.46</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M123" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.45</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.55</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.29</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3</oasis:entry>
         <oasis:entry colname="col2">Total systematic error (%)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:mn mathvariant="normal">7.60</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.18</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.26</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.16</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:mn mathvariant="normal">5.75</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.08</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4</oasis:entry>
         <oasis:entry colname="col2">Total random error (%)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M128" display="inline"><mml:mrow><mml:mn mathvariant="normal">3.23</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.77</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M129" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.56</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.94</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M130" display="inline"><mml:mrow><mml:mn mathvariant="normal">4.18</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2.66</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5</oasis:entry>
         <oasis:entry colname="col2">Intraday SD (%)</oasis:entry>
         <oasis:entry colname="col3">1.35</oasis:entry>
         <oasis:entry colname="col4">0.70</oasis:entry>
         <oasis:entry colname="col5">5.63</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">6</oasis:entry>
         <oasis:entry colname="col2">DFS</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M131" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.07</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.09</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.20</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.00</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e2497">The first row in Table <xref ref-type="table" rid="Ch1.T2"/> shows the total number of spectra/days for which the TCs have been obtained. Although the total number of spectra taken for SFIT4 processing was 4804 (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS1"/>), we had to remove 31 spectra for CFC-11 as they were measured with the incorrect filter (F3 instead f6 and vice versa). The retrieval technique for CFC-11 is very sensitive to the correctly defined filter (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS2"/> on BSS for CFC-11). Thus, the number of spectra for CFC-11 was 4773. The number of spectra is different for different gases, since the solution of the inverse problem algorithm implemented in SFIT4 does not always provide a solution. The total number of spectra suitable for processing for over more than 10 years of observations (from March 2009 to August 2019) is about 4500–4800, measured over about 720 d. Thus, on average, the FTIR measurements at the St. Petersburg site are carried out for 68 d yr<inline-formula><mml:math id="M134" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Such a relatively small number of days of measurements is primarily due to the latitude and climatic features of the site.</p>
      <p id="d1e2519">As we observed some outliers in the HCFC-22 TCs time series before 2016, we
discarded the TCs values that differed from the approximating line (trend) by more than three SD values. A total of 219 measurements were excluded; thus, the HCFC-22 spectra number is less then spectra numbers for two other gases. In the next step, we filtered the retrieved TCs using the following criterion: the deviation from the mean statistical characteristics presented in Table <xref ref-type="table" rid="Ch1.T2"/> should not be greater than <inline-formula><mml:math id="M135" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>×</mml:mo><mml:mtext>SD</mml:mtext></mml:mrow></mml:math></inline-formula>. Details of this selection are shown in Table <xref ref-type="table" rid="App1.Ch1.S2.T7"/> of Appendix <xref ref-type="sec" rid="App1.Ch1.S2"/>.</p>
      <p id="d1e2540">Table <xref ref-type="table" rid="Ch1.T3"/> gives some statistics for target gases measurements after filtering the retrievals. The general information on the spectra analyzed is given in row 1 (the number of measurement days and single measurements) and in row 2 (the spectral residuals). The number of days is close to 670, and the number of the retrieved TCs is close to 3900 for each gas. The spectral residual is the most important parameter of the retrieval;
it characterizes the quality of fitting the measured spectra with the calculated one. Ideally, the spectral residual should be equal to the measurement's noise level. For target gases, the mean values of the spectral residuals vary from 0.34 % to 0.52 %, depending on the gas; it corresponds to the signal-to-noise ratio (SNR) values of 209, 280, and 327 for CFC-11, CFC-12, and HCFC-22, respectively. Since the spectrum in residual calculations has been normalized to the unit, SNR and
residual are the reciprocal values, i.e., <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:mtext>SNR</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mtext>residual</mml:mtext></mml:mrow></mml:math></inline-formula>. Comparing these values to the preliminary determined mean SNR in the opaque
spectral range (364, 351, and 324 in the same order of gases), we see that, for CFC-11 and CFC-12, they are slightly less and, for HCFC-22, they are nearly the same. This means that, for CFC-11 and CFC-12, the radiative transfer model and a set of parameters used, although satisfactory, do not ideally describe the absorption of radiation by the atmosphere and the observational system, whereas, for HCFC-22, the retrieval technique works in the best way.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e2564">Summary of the statistics for retrieved halocarbon TCs after filtering.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">No.</oasis:entry>
         <oasis:entry colname="col2">Parameter</oasis:entry>
         <oasis:entry colname="col3">CFC-11</oasis:entry>
         <oasis:entry colname="col4">CFC-12</oasis:entry>
         <oasis:entry colname="col5">HCFC-22</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">No. of spectra/days</oasis:entry>
         <oasis:entry colname="col3">3864/678</oasis:entry>
         <oasis:entry colname="col4">3912/664</oasis:entry>
         <oasis:entry colname="col5">3855/663</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2</oasis:entry>
         <oasis:entry colname="col2">RMS (<inline-formula><mml:math id="M138" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M139" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.52</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.18</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.16</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.34</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3</oasis:entry>
         <oasis:entry colname="col2">Mean TC (cm<inline-formula><mml:math id="M142" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; Xgas; pptv)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:mn mathvariant="normal">4.75</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">15</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> (225)</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M144" display="inline"><mml:mrow><mml:mn mathvariant="normal">10.42</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">15</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> (493)</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:mn mathvariant="normal">5.04</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">15</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> (238)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4</oasis:entry>
         <oasis:entry colname="col2">Intraday SD of Xgas (%)</oasis:entry>
         <oasis:entry colname="col3">0.76</oasis:entry>
         <oasis:entry colname="col4">0.58</oasis:entry>
         <oasis:entry colname="col5">3.74 (4.54/2.32)<inline-formula><mml:math id="M146" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5</oasis:entry>
         <oasis:entry colname="col2">DFS</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.05</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.20</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.00</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">6</oasis:entry>
         <oasis:entry colname="col2">Trend (% yr<inline-formula><mml:math id="M150" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M151" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">7</oasis:entry>
         <oasis:entry colname="col2">Total SD of Xgas (%; except Fourier approx.)</oasis:entry>
         <oasis:entry colname="col3">2.8</oasis:entry>
         <oasis:entry colname="col4">2.1</oasis:entry>
         <oasis:entry colname="col5">5.3</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e2567"><inline-formula><mml:math id="M137" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> Before/after February 2016.</p></table-wrap-foot></table-wrap>

      <p id="d1e2924">Rows 3–7 of Table <xref ref-type="table" rid="Ch1.T3"/> present the characteristics of
the target gases retrievals, TCs, and Xgas. Row 3 shows the means, and row 4 shows the RMS intraday variability in Xgas, which can be interpreted as being their precision. Comparison of the RMS intraday variability values with the estimates of the random error (row 11 of Table <xref ref-type="table" rid="Ch1.T4"/>) demonstrates that, for HCFC-22, the intraday variability practically coincides with the total random error. The other two gases show a significantly different ratio, and the intraday variability is noticeably less than the random error (i.e., 0.76 % vs. 3.08 % for CFC-11 and 0.58 % vs. 2.40 % for CFC-12). Therefore, the random error has a significant component of a systematic nature during 1 d of measurements but randomly changes from 1 d to another. It should be noted that the temperature profile changes insignificantly during a day, so the intraday variability in Xgas includes the corresponding component and exceeds the contribution of a total random noise of spectroscopic measurements. Thus, the resulting error budget estimates and the intraday variability in the results are mutually consistent.</p>
      <p id="d1e2931">The DFS (row 5) for all gases is close to 1, which is primarily due to the <inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> approach and the selection of the regularization parameter <inline-formula><mml:math id="M155" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>, based on minimizing the intraday variability in the gas TCs. Row 6 of Table <xref ref-type="table" rid="Ch1.T3"/> shows the trend values estimated in accordance with a method described by <xref ref-type="bibr" rid="bib1.bibx11" id="text.49"/>. This method is based on the RMS approximation of the variability in gas concentrations by a three-term segment of the Fourier series and bootstrap method of confidence intervals assessment for 95 % probability. Finally, row 7 shows the RMS difference between Xgas and the trigonometric Fourier series used to estimate its temporal variability. For CFC-11 and CFC-12, these values are close to the random error (2.8 % vs. 3.08 % and 2.1 % vs. 2.40 %), which
indicates an adequate description of their variability by the Fourier series.
At the same time, for HCFC-22, the RMS difference is 5.3 %, which
exceeds the random error of 3.7 %, and the HCFC-22 variability involves some<?pagebreak page5356?> other components besides the trigonometric Fourier series. The reason for such behavior of HCFC-22 is a reduction in its use during the period analyzed that leads to a decrease in its growth rate. As a result, the representation of its variability in the form of a linear increase and seasonal variations, represented by trigonometric Fourier series (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>), cannot be accurate. <xref ref-type="bibr" rid="bib1.bibx36" id="text.50"/> demonstrated the decrease in a growth rate of HCFC-22 abundancies over St. Petersburg in the past decade.</p>
      <p id="d1e2965">The SFIT4 software provides the calculation of the error budget based on the
<xref ref-type="bibr" rid="bib1.bibx44" id="text.51"><named-content content-type="post">Chap. 3</named-content></xref> approach for each measurement.
<xref ref-type="bibr" rid="bib1.bibx44" id="text.52"><named-content content-type="post">Eq. 3.16</named-content></xref> considers the four components of the measurement error, namely the smoothing error, model parameter error, forward model error, and the retrieval noise. To estimate the mean smoothing error, it is necessary to have real covariance matrices of the gas vertical profiles, which are not available; therefore, we cannot estimate this component of the error. We can only assume that it is small because, due to their long lifetime, we expect nearly constant volume mixing ratio (VMR) profiles of the target gases in the troposphere. <xref ref-type="bibr" rid="bib1.bibx41" id="text.53"/> showed that the smoothing error for HCFC-22 is rather small (0.3 %). The model parameter error is caused by the inaccuracies in setting the parameters describing the instrument and the state of the atmosphere.</p>
      <p id="d1e2981">To calculate the terms of the model parameter error, which are shown in rows
1–7 of Table <xref ref-type="table" rid="Ch1.T4"/>, Eq. (3.18) in <xref ref-type="bibr" rid="bib1.bibx44" id="text.54"/> was used.
For this equation, it is necessary to first set the uncertainties of various
parameters which are taken into account. <xref ref-type="bibr" rid="bib1.bibx44" id="text.55"/> enters them as elements of the <inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>b</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> matrix; the corresponding column for these elements is presented in Table <xref ref-type="table" rid="Ch1.T4"/>. For the temperature profile (row 1) below 40 km, where the profiles of the target gases are derived, the absolute value of the temperature systematic error totals 1–2 K, and the random error totals 2–4 K, depending on the altitude. For other parameters, the relative errors are indicated in other rows of Table <xref ref-type="table" rid="Ch1.T4"/>. In addition to fixed parameters, two types of parameters are fitted in the retrieval process, namely (1) the retrieval parameters, including a number of instrumental parameters, such as BSS (a slope for all three gases and a curvature for CFC-11), along with instrumental line shape, channeling before 2016, zero level uncertainty, etc., and (2) the content of interfering atmospheric gases listed in Table <xref ref-type="table" rid="Ch1.T1"/> (column 3, other gases), for which the absorption lines overlap with the lines of the target gas. Their contribution to the error budget is shown in rows 8 (interfering species) and 9 (retrieval parameters). We assume that the forward model error  <xref ref-type="bibr" rid="bib1.bibx44" id="paren.56"><named-content content-type="post">Eq. 3.16</named-content></xref> is negligible in our retrieval. The retrieval noise shown in row 10 indicates the error corresponding to the spectra measurement noise.</p>
      <p id="d1e3015">Row 11 in Table <xref ref-type="table" rid="Ch1.T4"/> demonstrates that, for CFC-11 and HCFC-22,
total systematic errors are relatively large, amounting to 7.61 % and 5.75 %, and these values are almost entirely due to the uncertainty in the spectroscopic information on the intensities of pseudo-lines (row 3 of Table <xref ref-type="table" rid="Ch1.T4"/>). For CFC-12, the total systematic error is estimated as 2.2 %, and the main source of this error is the uncertainty of the temperature profile (row 1 of Table <xref ref-type="table" rid="Ch1.T4"/>). Note that the value of the total systematic error is slightly variable, and its SD is maximal for CFC-11, which comprises 0.16 %. The total random<?pagebreak page5357?> error and its variability is maximal for HCFC-22. The main contribution to it is made by the spectral measurement error, which is caused by the low absorption of the solar radiation by this gas. The random components of the total error for other two gases, 3.08 % and 2.40 %, are more stable, and their main source is the error in the temperature profile (see row 1). It should be noted that the filter used has a significant effect on the errors and variability in the HCFC-22 TCs. When switching to the IRWG NDACC f6 filter in February 2016, the intraday variability in the results (row 4 of Table <xref ref-type="table" rid="Ch1.T3"/>) decreased by approximately 2 times, and the random component of the total error (row 11 of Table <xref ref-type="table" rid="Ch1.T4"/>) decreased by 1.4 %, mainly due to the error of spectroscopic measurements. Due to channeling, the use of the F3 filter before February 2016 leads to a large scatter in retrieval results (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS1"/>).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e3034">Error budget for retrieved halocarbons TCs. The relative uncertainties of spectroscopic parameters are 7 %, 1 %,
and 5 % for CFC-11, CFC-12, and HCFC-22, respectively. <inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>b</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> means the a priori imprecision of parameters.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="9">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center" colsep="1"/>
     <oasis:colspec colnum="6" colname="col6" align="center"/>
     <oasis:colspec colnum="7" colname="col7" align="center" colsep="1"/>
     <oasis:colspec colnum="8" colname="col8" align="center"/>
     <oasis:colspec colnum="9" colname="col9" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">No.</oasis:entry>
         <oasis:entry colname="col2">Gas</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry namest="col4" nameend="col5" colsep="1">CFC-11 </oasis:entry>
         <oasis:entry namest="col6" nameend="col7" colsep="1">CFC-12 </oasis:entry>
         <oasis:entry namest="col8" nameend="col9">HCFC-22 </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry rowsep="1" namest="col4" nameend="col9">TCs error, % </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Parameter</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">S</mml:mi><mml:mi>b</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, %</oasis:entry>
         <oasis:entry colname="col4">Systematic</oasis:entry>
         <oasis:entry colname="col5">Random</oasis:entry>
         <oasis:entry colname="col6">Systematic</oasis:entry>
         <oasis:entry colname="col7">Random</oasis:entry>
         <oasis:entry colname="col8">Systematic</oasis:entry>
         <oasis:entry colname="col9">Random</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">Temperature</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M160" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.29</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.25</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M161" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.56</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.30</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.96</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.15</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.96</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.72</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.50</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">2</oasis:entry>
         <oasis:entry colname="col2">SZA</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.1</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M167" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.20</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.17</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M168" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.84</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.22</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.18</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.09</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.89</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M171" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.25</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M172" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.27</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.27</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">3</oasis:entry>
         <oasis:entry colname="col2">Target line intensity</oasis:entry>
         <oasis:entry colname="col3">7/1/5</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M173" display="inline"><mml:mrow><mml:mn mathvariant="normal">7.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.28</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M174" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.45</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M175" display="inline"><mml:mrow><mml:mn mathvariant="normal">5.04</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.45</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4</oasis:entry>
         <oasis:entry colname="col2">Target temperature</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">dependence of</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">line width</oasis:entry>
         <oasis:entry colname="col3">7/1/5</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.00</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M177" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.27</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5</oasis:entry>
         <oasis:entry colname="col2">Target air broadening</oasis:entry>
         <oasis:entry colname="col3">7/1/5</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M178" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M179" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.61</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M180" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.16</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.24</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">of line width</oasis:entry>
         <oasis:entry colname="col3">7/1/5</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M181" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M182" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.61</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M183" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.16</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.24</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">6</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M184" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> spectroscopy</oasis:entry>
         <oasis:entry colname="col3">10</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M185" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.45</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.57</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M186" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.31</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.31</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M187" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.35</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"/>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">7</oasis:entry>
         <oasis:entry colname="col2">Zshift</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M188" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M189" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.10</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M190" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.03</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.10</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M191" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M192" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M193" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.10</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M194" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.20</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">8</oasis:entry>
         <oasis:entry colname="col2">Interfering species</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry namest="col4" nameend="col5" colsep="1"><inline-formula><mml:math id="M195" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.04</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col6" nameend="col7" colsep="1"><inline-formula><mml:math id="M196" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col8" nameend="col9"><inline-formula><mml:math id="M197" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.19</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.12</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">9</oasis:entry>
         <oasis:entry colname="col2">Retrieval parameters</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry namest="col4" nameend="col5" colsep="1"><inline-formula><mml:math id="M198" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col6" nameend="col7" colsep="1"><inline-formula><mml:math id="M199" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col8" nameend="col9"><inline-formula><mml:math id="M200" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.29</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">10</oasis:entry>
         <oasis:entry colname="col2">Spectra measurement</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M201" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.29</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M202" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.20</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M203" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.66</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.62</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">noise</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9">(3.3/1.8)<inline-formula><mml:math id="M204" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">11</oasis:entry>
         <oasis:entry colname="col2">Total</oasis:entry>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M205" display="inline"><mml:mrow><mml:mn mathvariant="normal">7.61</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.16</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M206" display="inline"><mml:mrow><mml:mn mathvariant="normal">3.08</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.36</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M207" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.24</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M208" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.54</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M209" display="inline"><mml:mrow><mml:mn mathvariant="normal">5.75</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.08</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M210" display="inline"><mml:mrow><mml:mn mathvariant="normal">3.70</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.29</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5"/>
         <oasis:entry colname="col6"/>
         <oasis:entry colname="col7"/>
         <oasis:entry colname="col8"/>
         <oasis:entry colname="col9">(4.32/2.92)<inline-formula><mml:math id="M211" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e3048"><inline-formula><mml:math id="M158" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> Before/after February 2016. SZA is the solar zenith angle.</p></table-wrap-foot></table-wrap>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Analysis</title>
      <p id="d1e4113">Figures <xref ref-type="fig" rid="Ch1.F4"/>–<xref ref-type="fig" rid="Ch1.F6"/> show the results in a form of the daily means of both TCs and Xgas. The TC values directly represent the results of spectra inversion, while Xgas values are calculated by dividing the gas total column by the dry air total column. The analysis of Xgas values avoids the influence of the surface pressure and humidity variability, and thus, these values are more stable. To analyze the variability in target gases on a scale of both long-term trends and seasonal variability, we used the approach implemented by <xref ref-type="bibr" rid="bib1.bibx11" id="text.57"/> for assessing the trends, which is based on the approximation of a series of data by expansion on a finite-dimensional basis; see Eq. (<xref ref-type="disp-formula" rid="Ch1.E3"/>).
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M212" display="block"><mml:mrow><mml:mi>F</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:mi>a</mml:mi><mml:mo>+</mml:mo><mml:mi>b</mml:mi><mml:mi>t</mml:mi><mml:mo>+</mml:mo><mml:msub><mml:mi>c</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:msub><mml:mi>f</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mi>c</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi>f</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>+</mml:mo><mml:msub><mml:mi>c</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:msub><mml:mi>f</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          In Eq. (<xref ref-type="disp-formula" rid="Ch1.E3"/>), <inline-formula><mml:math id="M213" display="inline"><mml:mrow><mml:mi>F</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is a dependence approximated by the expansion, in our case represented by discrete measurement data, <inline-formula><mml:math id="M214" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> is time (years), <inline-formula><mml:math id="M215" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula> is the constant, and <inline-formula><mml:math id="M216" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula> is the linear term coefficient that is equal to a trend value. <inline-formula><mml:math id="M217" display="inline"><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M218" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M219" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> are the coefficients, <inline-formula><mml:math id="M220" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> is the number of coefficients, and <inline-formula><mml:math id="M221" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are the basis functions. Due to the annual cyclical nature of atmospheric processes, a trigonometric Fourier series with a maximum period of a year is used, which corresponds to the basis functions in  Eq. (<xref ref-type="disp-formula" rid="Ch1.E4"/>), as follows:
            <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M222" display="block"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi>i</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mi>cos⁡</mml:mi><mml:mo>(</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">π</mml:mi><mml:mi>i</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mspace linebreak="nobreak" width="0.25em"/><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mi>sin⁡</mml:mi><mml:mo>(</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">π</mml:mi><mml:mi>i</mml:mi><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi>m</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M223" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> or, which is the same, <inline-formula><mml:math id="M224" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula>. Let us write Eq. (<xref ref-type="disp-formula" rid="Ch1.E3"/>) in the form of Eq. (<xref ref-type="disp-formula" rid="Ch1.E5"/>), highlighting the nonlinear part <inline-formula><mml:math id="M225" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (Eq. <xref ref-type="disp-formula" rid="Ch1.E6"/>).
            <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M226" display="block"><mml:mrow><mml:mi>F</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>≈</mml:mo><mml:mi>a</mml:mi><mml:mo>+</mml:mo><mml:mi>b</mml:mi><mml:mi>t</mml:mi><mml:mo>+</mml:mo><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where, in the following:
            <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M227" display="block"><mml:mrow><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>c</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:msub><mml:mi>f</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mi>c</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi>f</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>+</mml:mo><mml:msub><mml:mi>c</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:msub><mml:mi>f</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          <inline-formula><mml:math id="M228" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> can be considered as being a periodic component of the measurement data time sequence, and its one period can be analyzed as a seasonal data variability. Figures <xref ref-type="fig" rid="Ch1.F4"/>–<xref ref-type="fig" rid="Ch1.F6"/>, in addition to the daily mean values
of Xgas and TC, also show, with a dashed line, the linear trend <inline-formula><mml:math id="M229" display="inline"><mml:mrow><mml:mi>a</mml:mi><mml:mo>+</mml:mo><mml:mi>b</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> and, with a solid black line, the result of approximating the measurement data by the trigonometric Fourier series in Eqs. (<xref ref-type="disp-formula" rid="Ch1.E3"/>) and (<xref ref-type="disp-formula" rid="Ch1.E4"/>).
Figure <xref ref-type="fig" rid="Ch1.F4"/> demonstrates a pronounced periodicity of the results,
showing the seasonal variation in both the TCs and Xgas of CFC-11. A similar periodicity is also observed in satellite measurements and in the WACCM data.
As expected, Xgas exhibit a slightly smaller scatter than TCs. Note that, starting from April 2019, there is a sharp increase in the concentrations
of CFC-11. At present, we have no way of explaining whether such growth is objectively presented or caused by peculiarities in the operation of the instrument. At the same time, this growth noticeably affects the trend estimates. Therefore, when calculating the trends of CFC-11 TCs and Xgas, we limited the CFC-11 time series to April 2019, leaving the analysis of the reasons for this feature outside the scope of this study.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e4595">Daily mean TCs and Xgas of CFC-11. The <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> parameter <inline-formula><mml:math id="M231" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">85</mml:mn></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f04.png"/>

        </fig>

      <p id="d1e4628">CFC-12 measurements (Fig. <xref ref-type="fig" rid="Ch1.F5"/>) show significantly different
results. First of all, the comparison of Figs. <xref ref-type="fig" rid="Ch1.F4"/> and <xref ref-type="fig" rid="Ch1.F5"/> and estimates of the intraday variability and measurement uncertainties of these gases demonstrate that the TCs and Xgas of CFC-12 show less scatter than that of CFC-11, except for some isolated anomalies.
The seasonal variability in these values for CFC-12 is noticeably less than
that for CFC-11. We also note that, moving from TCs to Xgas, the deviations in the results from the approximating segment of the Fourier series decrease significantly. Variations in surface pressure and water vapor TCs make a significant contribution to the variability in CFC-12 TCs, which indicates small changes in its VMR profile. We analyze these factors in detail in Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e4642">Daily mean TCs and Xgas of CFC-12. Filtered results of the <inline-formula><mml:math id="M232" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> parameter <inline-formula><mml:math id="M233" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">85</mml:mn></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f05.png"/>

        </fig>

      <p id="d1e4675">Having considered the results of measurements of HCFC-22 daily means, we observed a large variability consistent with a large random component of the total error estimates (see Table <xref ref-type="table" rid="Ch1.T4"/>). There are also noticeable seasonal variations. At first glance, the filter change in February 2016 clearly manifests itself in a change in the data scatter, but in 2016, the scatter looks no less than in previous years and sharply decreases in 2017 and later. Noteworthy is the observed cessation of the increase in HCFC-22 values starting from 2018, previously described by <xref ref-type="bibr" rid="bib1.bibx36" id="text.58"/>.
We also observed an increase in the scatter of the results for all three gases in 2013 due to a decrease in the SNR values caused by the degradation of the tracking system mirror.</p>

      <fig id="Ch1.F6" specific-use="star"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e4684">Daily mean TCs and Xgas of HCFC-22. Filtered results of the <inline-formula><mml:math id="M234" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> parameter <inline-formula><mml:math id="M235" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f06.png"/>

        </fig>

      <p id="d1e4724">Table <xref ref-type="table" rid="Ch1.T5"/> presents trend estimates for Xgas time series using two different methods described by <xref ref-type="bibr" rid="bib1.bibx11" id="text.59"/> and <xref ref-type="bibr" rid="bib1.bibx52" id="text.60"/>. <xref ref-type="bibr" rid="bib1.bibx11" id="text.61"/> model the intra-annual variability in terms of a Fourier series, and <xref ref-type="bibr" rid="bib1.bibx52" id="text.62"/> use monthly mean values of the considered period to describe a seasonal cycle. In both methods, trends are estimated by subtracting the seasonal variability from initial time series. In the first method, we consider periodicities of 4 months and larger; in the second method, the<?pagebreak page5358?> monthly mean values account for periodicities from 1 month.
The estimation of the width of the confidence interval of the trend value for Gardiner's approach is carried out using the bootstrap method; for Timofeev's method, it is calculated on the basis of a theoretical statistical approach. We do not take the autocorrelation that can be presented in long-lived Xgas time series into account. <xref ref-type="bibr" rid="bib1.bibx46" id="text.63"/> demonstrated that neglecting the autocorrelation in a time series could affect the trends estimates and underestimate uncertainties; however, due to substantially irregular FTIR measurements, it was difficult to estimate it.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T5"><?xmltex \currentcnt{5}?><label>Table 5</label><caption><p id="d1e4748">Estimated trends of Xgas derived from the FTIR measurements at the
St. Petersburg site in 2009–2019.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Gas</oasis:entry>
         <oasis:entry colname="col2">
                    <xref ref-type="bibr" rid="bib1.bibx11" id="text.64"/>
                  </oasis:entry>
         <oasis:entry colname="col3">
                    <xref ref-type="bibr" rid="bib1.bibx52" id="text.65"/>
                  </oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">CFC-11</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M236" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M237" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.39</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.08</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CFC-12</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M238" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M239" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.46</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">HCFC-22</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M240" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M241" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.22</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e4891">Table <xref ref-type="table" rid="Ch1.T5"/> demonstrates that the differences between two methods remain within the 95 % confidence interval, i.e., they are not significant.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Comparison with independent data</title>
      <p id="d1e4904">We compared the FTIR results at the St. Petersburg site with the data of
measurements and modeling. There are three sources of data for the concentration of halocarbons in the atmosphere. First, the in situ measurements at the surface (carried out exactly by the in situ and flask methods) are available from the AGAGE <xref ref-type="bibr" rid="bib1.bibx8" id="paren.66"/> and HATS <xref ref-type="bibr" rid="bib1.bibx30" id="paren.67"/> observational networks; the data are regularly updated at <uri>ftp://ftp.cmdl.noaa.gov/hats</uri> (last access: 28 June 2020). Measurements are carried out at fixed locations, the closest of which is Mace Head, Ireland (MHD), at a distance of 2500 km and 6.6<inline-formula><mml:math id="M242" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> south of the St. Petersburg site. The mean values and the trends of Xgas were calculated from the FTIR data and from the MHD site near-ground data for the period (2009–2019) for all three gases. The results are shown in Table <xref ref-type="table" rid="Ch1.T6"/> in columns 1 and 3. The mean near-ground VMRs (GVMRs) at the MHD site for CFC-11, CFC-12, and
HCFC-22 equal 234, 517, and 237 pptv (parts per trillion by volume), whereas the FTIR Xgas measurements show 225, 493, and 252 pptv means, respectively. The trend values (Table <xref ref-type="table" rid="Ch1.T6"/>; columns 2 and 4) for the GVMR data are <inline-formula><mml:math id="M243" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.53</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M244" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.59</mml:mn></mml:mrow></mml:math></inline-formula>, and 2.0 % yr<inline-formula><mml:math id="M245" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; for the FTIR data, they are <inline-formula><mml:math id="M246" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.38</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M247" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.48</mml:mn></mml:mrow></mml:math></inline-formula>, and 2.0 % yr<inline-formula><mml:math id="M248" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for CFC-11, CFC-12, and HCFC-22, respectively. Taking into account the spatial discrepancy, the different nature of the measured quantities and the different measurement conditions (background conditions on the Atlantic coast and measurements near the large agglomeration of St. Petersburg), the agreement between the mean values and the trends can be considered satisfactory. It should be noted that the differences in trend estimates do not go beyond the differences in trend values obtained by other researchers. <xref ref-type="bibr" rid="bib1.bibx58" id="text.68"/> obtained trends of <inline-formula><mml:math id="M249" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.86</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M250" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, <inline-formula><mml:math id="M251" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.76</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M252" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, and <inline-formula><mml:math id="M253" display="inline"><mml:mn mathvariant="normal">2.84</mml:mn></mml:math></inline-formula> % yr<inline-formula><mml:math id="M254" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the period 2009–2016; <xref ref-type="bibr" rid="bib1.bibx55" id="text.69"/> indicated that averaged VMRs for 2015 comprised  229.2–231.1, 515.3–519.7, and 233.0–238.0 pptv, and the
trends for the period 2010–2016 were <inline-formula><mml:math id="M255" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.70</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M256" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, <inline-formula><mml:math id="M257" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.47</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M258" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, and 2.54 % yr<inline-formula><mml:math id="M259" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for CFC-11, CFC-12, and HCFC-22, respectively. Taking into account the decrease in both the rate of decay of CFC-11 and the rate of growth of HCFC-22 <xref ref-type="bibr" rid="bib1.bibx36" id="paren.70"><named-content content-type="pre">e.g.,</named-content></xref>, the<?pagebreak page5360?> agreement of both concentrations and trend values seems to be satisfactory.</p>
      <p id="d1e5127">The second source of information on the halocarbons content is the satellite
measurements, presented most fully for target gases by the ACE-FTS instrument data (for which version 4 is described by <xref ref-type="bibr" rid="bib1.bibx5" id="altparen.71"/>). The ACE-FTS is a high spectral resolution (0.02 cm<inline-formula><mml:math id="M260" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) Fourier transform spectrometer operating from 2.2 to 13.3 <inline-formula><mml:math id="M261" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> (750–4400 cm<inline-formula><mml:math id="M262" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), based on a Michelson interferometer. The instrument is a main payload on board the SCISAT-1 satellite, with a drifting orbit, an inclination of 73.9<inline-formula><mml:math id="M263" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>, and an altitude of 750 km. Working primarily in the solar occultation mode, the satellite provides information on vertical profiles (typically 10–100 km) for temperature, pressure, and the VMRs of dozens of atmospheric gases over the latitudes of 85<inline-formula><mml:math id="M264" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N to 85<inline-formula><mml:math id="M265" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> S. The lower boundary of the retrieved profiles does not fall below 6 km, but, as a rule, it is above 7–8 km, and the errors at the lower level may be greater than in the rest of the profile. Therefore, we used, for comparisons only, the profiles in which the data were available
above 7 km and analyzed the average satellite VMRs (SVMR) in the 8–12 km
layer to reduce the random error. For comparison, we selected the ACE-FTS measurements closer than 500 km from the St. Petersburg site.
In 2009–2019,  there are only 47 d of SVMR measurements for CFC-11 (mean 233 pptv; trend <inline-formula><mml:math id="M266" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.68</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.23</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M267" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), 47 d for CFC-12 (mean 521 pptv; trend <inline-formula><mml:math id="M268" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.52</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.16</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M269" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), and 46 d for HCFC-22 (mean 240 pptv; trend <inline-formula><mml:math id="M270" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M271" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). The results are shown in columns 7 and 8 of Table <xref ref-type="table" rid="Ch1.T6"/>. Due to the peculiarity of the orbit and the weather conditions at the St. Petersburg site, SCISAT-1 measurements are available on rare occasions; during 10 years, we have not found more than 47 measurements closer than 500 km to the St. Petersburg site. However, the 95 % probability intervals show the reliability of the trend estimates, using the bootstrap method by <xref ref-type="bibr" rid="bib1.bibx11" id="text.72"/>. As one can see, by comparing columns 1 and 7 of Table <xref ref-type="table" rid="Ch1.T6"/>, the confidence intervals of the means overlap, i.e., the difference in the mean values is not significant only for HCFC-22, and for both CFC-11 and CFC-12, the SVMR is significantly greater than the FTIR Xgas; the difference totals 8 pptv, or 3.5 % for CFC-11 and 28 pptv or 6.3 % for CFC-12. To increase the number of data pairs, we analyzed all ACE-FTS data at all longitudes in the 55–65<inline-formula><mml:math id="M272" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N latitudinal range, including the St. Petersburg site (about 60<inline-formula><mml:math id="M273" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N). For the period of the FTIR measurements, the SVMR data include 1113 measurements for CFC-11, with the mean of 235.3 pptv and the trend value of <inline-formula><mml:math id="M274" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.63</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M275" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, 1120 measurements for CFC-12
(526.4 pptv, <inline-formula><mml:math id="M276" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.58</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M277" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), and 1111 measurements for HCFC-22
(239.5 pptv, 2.2 % yr<inline-formula><mml:math id="M278" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; see columns 5 and 6 of
Table <xref ref-type="table" rid="Ch1.T6"/>).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T6" specific-use="star"><?xmltex \currentcnt{6}?><label>Table 6</label><caption><p id="d1e5360">The means and the trends estimates of the FTIR Xgas, GVMR, and SVMR measurements, and the WXgas. If the width of the confidence interval is not specified, then it is less than the last significant digit.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.95}[.95]?><oasis:tgroup cols="11">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right" colsep="1"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="right" colsep="1"/>
     <oasis:colspec colnum="6" colname="col6" align="center"/>
     <oasis:colspec colnum="7" colname="col7" align="right" colsep="1"/>
     <oasis:colspec colnum="8" colname="col8" align="center"/>
     <oasis:colspec colnum="9" colname="col9" align="right" colsep="1"/>
     <oasis:colspec colnum="10" colname="col10" align="center"/>
     <oasis:colspec colnum="11" colname="col11" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Gas</oasis:entry>
         <oasis:entry namest="col2" nameend="col3" align="center" colsep="1">FTIR, </oasis:entry>
         <oasis:entry namest="col4" nameend="col5" colsep="1">Mace Head, </oasis:entry>
         <oasis:entry namest="col6" nameend="col9" colsep="1">ACE-FTS, mean VMR 8–12 km, SVMR </oasis:entry>
         <oasis:entry namest="col10" nameend="col11">WACCM, WXgas </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" namest="col2" nameend="col3" align="center" colsep="1">St. Petersburg, Xgas </oasis:entry>
         <oasis:entry rowsep="1" namest="col4" nameend="col5" colsep="1">Ireland, GVMR </oasis:entry>
         <oasis:entry rowsep="1" namest="col6" nameend="col7" colsep="1">55 65<inline-formula><mml:math id="M279" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N </oasis:entry>
         <oasis:entry rowsep="1" namest="col8" nameend="col9" colsep="1">Distance <inline-formula><mml:math id="M280" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">500</mml:mn></mml:mrow></mml:math></inline-formula> km </oasis:entry>
         <oasis:entry rowsep="1" namest="col10" nameend="col11">St. Petersburg </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Mean,</oasis:entry>
         <oasis:entry colname="col3">Trend,</oasis:entry>
         <oasis:entry colname="col4">Mean,</oasis:entry>
         <oasis:entry colname="col5">Trend,</oasis:entry>
         <oasis:entry colname="col6">Mean,</oasis:entry>
         <oasis:entry colname="col7">Trend,</oasis:entry>
         <oasis:entry colname="col8">Mean,</oasis:entry>
         <oasis:entry colname="col9">Trend,</oasis:entry>
         <oasis:entry colname="col10">Mean,</oasis:entry>
         <oasis:entry colname="col11">Trend</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" colname="col2">pptv</oasis:entry>
         <oasis:entry rowsep="1" colname="col3">% yr<inline-formula><mml:math id="M281" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry rowsep="1" colname="col4">pptv</oasis:entry>
         <oasis:entry rowsep="1" colname="col5">% yr<inline-formula><mml:math id="M282" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry rowsep="1" colname="col6">pptv</oasis:entry>
         <oasis:entry rowsep="1" colname="col7">% yr<inline-formula><mml:math id="M283" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry rowsep="1" colname="col8">pptv</oasis:entry>
         <oasis:entry rowsep="1" colname="col9">% yr<inline-formula><mml:math id="M284" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry rowsep="1" colname="col10">pptv</oasis:entry>
         <oasis:entry rowsep="1" colname="col11">% yr<inline-formula><mml:math id="M285" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry colname="col3">2</oasis:entry>
         <oasis:entry colname="col4">3</oasis:entry>
         <oasis:entry colname="col5">4</oasis:entry>
         <oasis:entry colname="col6">5</oasis:entry>
         <oasis:entry colname="col7">6</oasis:entry>
         <oasis:entry colname="col8">7</oasis:entry>
         <oasis:entry colname="col9">8</oasis:entry>
         <oasis:entry colname="col10">9</oasis:entry>
         <oasis:entry colname="col11">10</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">CFC-11</oasis:entry>
         <oasis:entry colname="col2">225</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M286" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">234</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M287" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.53</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">235</oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M288" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.63</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M289" display="inline"><mml:mrow><mml:mn mathvariant="normal">233</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M290" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.68</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.23</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M291" display="inline"><mml:mrow><mml:mn mathvariant="normal">203</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col11"><inline-formula><mml:math id="M292" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.68</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CFC-12</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M293" display="inline"><mml:mrow><mml:mn mathvariant="normal">493</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M294" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">517</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M295" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.59</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">526</oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M296" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.58</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M297" display="inline"><mml:mrow><mml:mn mathvariant="normal">521</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M298" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.52</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.16</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M299" display="inline"><mml:mrow><mml:mn mathvariant="normal">478</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col11"><inline-formula><mml:math id="M300" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.84</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">HCFC-22</oasis:entry>
         <oasis:entry colname="col2">238</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M301" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">237</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M302" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">240</oasis:entry>
         <oasis:entry colname="col7">2.2</oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M303" display="inline"><mml:mrow><mml:mn mathvariant="normal">240</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M304" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M305" display="inline"><mml:mrow><mml:mn mathvariant="normal">215</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col11"><inline-formula><mml:math id="M306" display="inline"><mml:mrow><mml:mn mathvariant="normal">3.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

      <p id="d1e5953">With a 20 times larger data set, the confidence intervals for the trends for the latitudinal range are much narrower than for a circle with a radius of
500 km; thus, differences in the SVMR trends vs. FTIR Xgas trends for CFC-11 and CFC-12 become significant. Such a discrepancy may be due to the different physical nature of the compared quantities. The satellite data do not take into account the lower tropospheric layers, where the influence of anthropogenic pollution sources is the greatest. Therefore, analyzing the trends and deriving from this that the background values of the VMRs for atmospheric CFC-11 and CFC-12 (in situ and satellite) are falling faster than the FTIR Xgas in the industrially developed European part of Russia (near the megacity of St. Petersburg), we may assume that some sources of CFC-11 and CFC-12 exist somewhere there. The absolute values of CFC-11 and CFC-12 FTIR Xgas are smaller than that of the in situ and satellite measurements, but this may only be due to the uncertainty of the spectroscopy used (see the estimates of the systematic in Table <xref ref-type="table" rid="Ch1.T4"/>; row 3).</p>
      <p id="d1e5958">Figure <xref ref-type="fig" rid="Ch1.F7"/> depicts seasonal variation functions <inline-formula><mml:math id="M307" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, in Eq. (<xref ref-type="disp-formula" rid="Ch1.E6"/>), for three gases and for four types of data, i.e., near-ground VMR (GVMR) at the MHD station, satellite mean VMR (SVMR) 8–12 km (55–65<inline-formula><mml:math id="M308" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N), the Xgas by FTIR measurements (Xgas), and the Xgas from the WACCM (WXgase).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7" specific-use="star"><?xmltex \currentcnt{7}?><?xmltex \def\figurename{Figure}?><label>Figure 7</label><caption><p id="d1e5990">Seasonal relative variability in CFC-11 <bold>(a)</bold>, CFC-12 <bold>(b)</bold>, and HCFC-22 <bold>(c)</bold>. Satellite refers to the ACE-FTS measurements; ground-based and WACCM refer to the FTIR measurements and numerical modeling at the St. Petersburg site.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f07.png"/>

        </fig>

      <p id="d1e6008">There are some fundamental differences between local surface and remote sensing measurements (satellite and ground-based FTIR). First, surface measurements are performed regularly and frequently, resulting in stable averages. Second, they are unaffected by variations in pressure and tropopause height. And, finally, the surface data used were obtained in close to background conditions. Therefore, Fig. <xref ref-type="fig" rid="Ch1.F7"/> demonstrates the low seasonal variability in the GVMR, which is within tenths of a percent for CFC-11 and CFC-12 and within 0.7 % for HCFC-22. At the same time, a noticeable seasonal variation in the FTIR Xgas and the SVMR values for all three gases and of the WACCM Xgas for CFC-11 and CFC-12 are observed. The maximal amplitude of the variability reaches 4 % for CFC-11, slightly exceeds 3 % for HCFC-22, and is close to 2 % for CFC-12. For all three gases, seasonal variations in SVMR and Xgas are qualitatively and quantitatively similar; in spring (March–April), there is a minimum, and in late summer or autumn (August–October), there is a maximum. At the same time, there are some differences in the seasonal cycles. For CFC-11, the change in Xgas is 2–3 months ahead of SVMR, while for HCFC-22 the autumn maximum shows the same tendency, whereas the spring minimum, on the contrary, is observed simultaneously for Xgas and SVMR. For CFC-12, the Xgas amplitude is approximately half that for two other gases; the spring minimum of Xgas, on the contrary, is observed before that of SVMR, and the autumn maxima coincide. For CFC-12, a second maximum in the Xgas seasonal cycle is
observed in the early summer. WXgas for CFC-11 and CFC-12, on the whole, show a qualitatively and quantitatively similar seasonal variability to Xgas and SVMR, while, on the contrary, for HCFC-22, the changes in WXgas are
significantly less (less than 1 %) than that of Xgas and  SVMR. In general, we can conclude that Xgas, SVMR, and WXgas show qualitatively similar seasonal variation, with some quantitative<?pagebreak page5361?> differences, and the GVMR variabilities are significantly less. The variability in WXgas for HCFC-22 depicts the only exception; it is essentially less than the Xgas and SVMR variability.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e6022"><list list-type="order">
          <list-item>

      <p id="d1e6027">The retrieval strategies for deriving TCs of CFC-11, CFC-12, and HCFC-22, using ground-based IR solar spectra measurements by the Bruker IFS125HR spectrometer at the NDACC site of St. Petersburg were improved. To solve the inverse problem, values of the regularization parameter of the <inline-formula><mml:math id="M309" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">Ph</mml:mi></mml:mrow></mml:math></inline-formula> approach were optimized. The time series of TCs and Xgas for CFC-11, CFC-12, and HCFC-22, above the St. Petersburg site near St. Petersburg, Russia in 2009–2019, were obtained. The estimates of the DFS values are <inline-formula><mml:math id="M310" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.05</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M311" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.20</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M312" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.00</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.00</mml:mn></mml:mrow></mml:math></inline-formula>; the estimates of the relative systematic and random errors are 7.61 % and 3.08 %, 2.24 % and 2.40 %, and 5.75 % and 3.70 %, for CFC-11, CFC-12, and HCFC-22, respectively.</p>
          </list-item>
          <list-item>

      <p id="d1e6081">Mean values of <inline-formula><mml:math id="M313" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M314" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M315" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> are 225, 493, and 238 pptv. The RMS intraday variability in TCs of measured gases is 0.8 %, 0.6 %, and 2.3 % for the three gases in the same order. Estimates of the Xgas trends of CFC-11, CFC-12, and HCFC-22 equal <inline-formula><mml:math id="M316" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M317" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, <inline-formula><mml:math id="M318" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M319" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, and <inline-formula><mml:math id="M320" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M321" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, respectively. The analysis of the seasonal variability in CFC-11, CFC-12, and HCFC-22 demonstrates the similar qualitative seasonal variability for all three gases, with a minimum in spring–early summer and a maximum in fall; <inline-formula><mml:math id="M322" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M323" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> variability amounts to 3 %, and the variability in <inline-formula><mml:math id="M324" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> amounts to 2 %.</p>
          </list-item>
          <list-item>

      <p id="d1e6261">Mean values, trends, and the seasonal variability in  <inline-formula><mml:math id="M325" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M326" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M327" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> above the St. Petersburg site were compared to the same parameters of the near-ground VMRs measured at the site in  Mace Head, Ireland. It is shown that the mean of <inline-formula><mml:math id="M328" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> above the St. Petersburg site is 9 pptv (3.8 %) less than the mean GVMR at the MHD site, the mean of  <inline-formula><mml:math id="M329" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 24 pptv (4.6 %) less than the mean GVMR, and the mean of <inline-formula><mml:math id="M330" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> does not significantly differ from the mean GVMR. In absolute values, the trend of <inline-formula><mml:math id="M331" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 0.13 % yr<inline-formula><mml:math id="M332" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>  less (<inline-formula><mml:math id="M333" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn></mml:mrow></mml:math></inline-formula> vs. <inline-formula><mml:math id="M334" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.53</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M335" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) than that of the GVMR, the trend of <inline-formula><mml:math id="M336" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 0.10 % yr<inline-formula><mml:math id="M337" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> less (<inline-formula><mml:math id="M338" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M339" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> vs. <inline-formula><mml:math id="M340" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.59</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M341" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) than that of the GVMR, and the trend of <inline-formula><mml:math id="M342" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> does not significantly differ from that of GVMR (<inline-formula><mml:math id="M343" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M344" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>  vs. <inline-formula><mml:math id="M345" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M346" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). The seasonal variability in GVMR for all three gases is much lower than the Xgas variability.</p>
          </list-item>
          <list-item>

      <?pagebreak page5362?><p id="d1e6562">Mean values, trends, and the seasonal variability in <inline-formula><mml:math id="M347" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M348" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M349" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> above the St. Petersburg site were compared to the same parameters of SVMR. SVMR stands for the mean values of VMR, measured with ACE–FTS between altitudes of 8–12 km and between latitudes of 55–65<inline-formula><mml:math id="M350" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> N. It is shown that the mean <inline-formula><mml:math id="M351" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 10 pptv (4.3 %) less than the mean SVMR, the mean <inline-formula><mml:math id="M352" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 33 pptv (6.3 %) less than the mean SVMR, and the mean <inline-formula><mml:math id="M353" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 2 pptv (0.8 %) less than the mean SVMR. In terms of the absolute value, the <inline-formula><mml:math id="M354" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> trend is 0.23 % yr<inline-formula><mml:math id="M355" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> less (<inline-formula><mml:math id="M356" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M357" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> vs. <inline-formula><mml:math id="M358" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.63</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M359" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>) than the trend of SVMR, the trend of <inline-formula><mml:math id="M360" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 0.09 % yr<inline-formula><mml:math id="M361" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> less than the trend of SVMR (<inline-formula><mml:math id="M362" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M363" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> vs. <inline-formula><mml:math id="M364" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.58</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M365" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), and the trend of <inline-formula><mml:math id="M366" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> does not significantly differ from that of SVMR (<inline-formula><mml:math id="M367" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.12</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula> vs. 2.2 % yr<inline-formula><mml:math id="M368" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). Xgas and SVMR show qualitatively and quantitatively similar seasonal variations.</p>
          </list-item>
          <list-item>

      <p id="d1e6860">Mean values, trends, and seasonal variability in  <inline-formula><mml:math id="M369" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M370" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M371" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> were compared to the same parameters of WXgas. WXgas stands for Xgas calculated on the basis of the WACCM data set of the VMR profiles for the St. Petersburg site. It is shown that the mean <inline-formula><mml:math id="M372" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 22 pptv (10 %) greater than the mean <inline-formula><mml:math id="M373" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, the mean <inline-formula><mml:math id="M374" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 15 pptv (3.1 %) greater than the mean <inline-formula><mml:math id="M375" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and the mean <inline-formula><mml:math id="M376" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 23 pptv (10 %) greater than the mean <inline-formula><mml:math id="M377" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>. In terms of the absolute value, the <inline-formula><mml:math id="M378" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> trend is 1.28 % yr<inline-formula><mml:math id="M379" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> less than the trend of <inline-formula><mml:math id="M380" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M381" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.40</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M382" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> vs.  <inline-formula><mml:math id="M383" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.68</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M384" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), the trend of <inline-formula><mml:math id="M385" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 0.35 % yr<inline-formula><mml:math id="M386" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> less than the trend of <inline-formula><mml:math id="M387" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">12</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M388" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.49</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M389" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> vs. <inline-formula><mml:math id="M390" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.84</mml:mn></mml:mrow></mml:math></inline-formula> % yr<inline-formula><mml:math id="M391" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>), and the trend of <inline-formula><mml:math id="M392" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is 1.28 % yr<inline-formula><mml:math id="M393" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> less than the trend of <inline-formula><mml:math id="M394" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">CFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> (2.12 % yr<inline-formula><mml:math id="M395" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> vs. 3.40 % yr<inline-formula><mml:math id="M396" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>). Xgas and WXgas show qualitatively and quantitatively similar seasonal variations for CFC-11 and CFC-12; the seasonal variability in the <inline-formula><mml:math id="M397" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">WX</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is essentially less than <inline-formula><mml:math id="M398" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:mi mathvariant="normal">HCFC</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">22</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> variability.</p>
          </list-item>
        </list></p>
      <p id="d1e7290"><?xmltex \hack{\newpage}?>In general, the comparison of the FTIR Xgas with the independent data shows a good agreement of their means within the systematic error of the measurements. The trends observed over the St. Petersburg site demonstrate the smaller decrease rates for CFC-11 and CFC-12 than the independent data and the same increase rate for HCFC-22.</p><?xmltex \hack{\clearpage}?>
</sec>

      
      </body>
    <back><app-group>

<?pagebreak page5363?><app id="App1.Ch1.S1">
  <?xmltex \currentcnt{A}?><label>Appendix A</label><title>Spectra samples</title>

      <?xmltex \floatpos{h!}?><fig id="App1.Ch1.S1.F8"><?xmltex \currentcnt{A1}?><?xmltex \def\figurename{Figure}?><label>Figure A1</label><caption><p id="d1e7309">Absorption by various gases in the spectral region of the CFC-11 absorption band (7 November 2017, 09:57 UTC; SZA is 76<inline-formula><mml:math id="M399" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>).</p></caption>
        <?xmltex \hack{\hsize\textwidth}?>
        <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f08.png"/>

      </fig>

      <?xmltex \floatpos{h!}?><fig id="App1.Ch1.S1.F9"><?xmltex \currentcnt{A2}?><?xmltex \def\figurename{Figure}?><label>Figure A2</label><caption><p id="d1e7331">Absorption by various gases in the spectral region of the CFC-12 absorption band (1160 cm<inline-formula><mml:math id="M400" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; 19 June 2017, 10:25 UTC; SZA is 37<inline-formula><mml:math id="M401" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>).</p></caption>
        <?xmltex \hack{\hsize\textwidth}?>
        <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f09.png"/>

      </fig>

      <?xmltex \floatpos{h!}?><fig id="App1.Ch1.S1.F10"><?xmltex \currentcnt{A3}?><?xmltex \def\figurename{Figure}?><label>Figure A3</label><caption><p id="d1e7366">Absorption by various gases in the spectral region near the HCFC-22 absorption line (829 cm<inline-formula><mml:math id="M402" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; 19 June 2017, 10:25 UTC; SZA is 37<inline-formula><mml:math id="M403" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>).</p></caption>
        <?xmltex \hack{\hsize\textwidth}?>
        <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/5349/2021/amt-14-5349-2021-f10.png"/>

      </fig>

<?xmltex \hack{\clearpage}?>
</app>

<?pagebreak page5364?><app id="App1.Ch1.S2">
  <?xmltex \currentcnt{B}?><label>Appendix B</label><title>Results filtering</title>
      <p id="d1e7408">We filtered the retrieved TCs using the following criteria. The SNR of measured spectra should be in the range of 50–600, and the deviation from the mean statistical characteristics presented in  Table <xref ref-type="table" rid="Ch1.T2"/> should not be greater than 2 times the SD. The criteria used and the percentage of the measurements discarded after their application are shown in Table <xref ref-type="table" rid="App1.Ch1.S2.T7"/>.</p>

<?xmltex \floatpos{h!}?><table-wrap id="App1.Ch1.S2.T7"><?xmltex \hack{\hsize\textwidth}?><?xmltex \currentcnt{B1}?><label>Table B1</label><caption><p id="d1e7419">The criteria used and the percentage of data discarded after their application.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right" colsep="1"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="center" colsep="1"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Criterion</oasis:entry>
         <oasis:entry rowsep="1" namest="col2" nameend="col3" align="center" colsep="1">CFC-11 </oasis:entry>
         <oasis:entry rowsep="1" namest="col4" nameend="col5" align="center" colsep="1">CFC-12 </oasis:entry>
         <oasis:entry rowsep="1" namest="col6" nameend="col7" align="center">HCFC-22 </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Value</oasis:entry>
         <oasis:entry colname="col3">Excluded (%)</oasis:entry>
         <oasis:entry colname="col4">Value</oasis:entry>
         <oasis:entry colname="col5">Excluded (%)</oasis:entry>
         <oasis:entry colname="col6">Value</oasis:entry>
         <oasis:entry colname="col7">Excluded (%)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Sys error</oasis:entry>
         <oasis:entry colname="col2">7.96</oasis:entry>
         <oasis:entry colname="col3">2.9</oasis:entry>
         <oasis:entry colname="col4">2.58</oasis:entry>
         <oasis:entry colname="col5">2.5</oasis:entry>
         <oasis:entry colname="col6">5.91</oasis:entry>
         <oasis:entry colname="col7">0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Ran error</oasis:entry>
         <oasis:entry colname="col2">4.77</oasis:entry>
         <oasis:entry colname="col3">5.0</oasis:entry>
         <oasis:entry colname="col4">4.42</oasis:entry>
         <oasis:entry colname="col5">4.7</oasis:entry>
         <oasis:entry colname="col6">9.50</oasis:entry>
         <oasis:entry colname="col7">4.8</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M404" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">1.449</oasis:entry>
         <oasis:entry colname="col3">0.5</oasis:entry>
         <oasis:entry colname="col4">1.540</oasis:entry>
         <oasis:entry colname="col5">0.3</oasis:entry>
         <oasis:entry colname="col6">0.971</oasis:entry>
         <oasis:entry colname="col7">4.1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">DFS</oasis:entry>
         <oasis:entry colname="col2">0.89</oasis:entry>
         <oasis:entry colname="col3">0</oasis:entry>
         <oasis:entry colname="col4">1.10</oasis:entry>
         <oasis:entry colname="col5">1.3</oasis:entry>
         <oasis:entry colname="col6">0.90</oasis:entry>
         <oasis:entry colname="col7">0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SNR</oasis:entry>
         <oasis:entry colname="col2">50–600</oasis:entry>
         <oasis:entry colname="col3">7.9</oasis:entry>
         <oasis:entry colname="col4">50–600</oasis:entry>
         <oasis:entry colname="col5">3.7</oasis:entry>
         <oasis:entry colname="col6">60–600</oasis:entry>
         <oasis:entry colname="col7">4.2</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Not conv.</oasis:entry>
         <oasis:entry colname="col2">Yes</oasis:entry>
         <oasis:entry colname="col3">0</oasis:entry>
         <oasis:entry colname="col4">Yes</oasis:entry>
         <oasis:entry colname="col5">8.1</oasis:entry>
         <oasis:entry colname="col6">Yes</oasis:entry>
         <oasis:entry colname="col7">3.7</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Div.</oasis:entry>
         <oasis:entry colname="col2">Yes</oasis:entry>
         <oasis:entry colname="col3">3.8</oasis:entry>
         <oasis:entry colname="col4">Yes</oasis:entry>
         <oasis:entry colname="col5">0</oasis:entry>
         <oasis:entry colname="col6">Yes</oasis:entry>
         <oasis:entry colname="col7">3.0</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">No result</oasis:entry>
         <oasis:entry colname="col2">No files</oasis:entry>
         <oasis:entry colname="col3">4.2</oasis:entry>
         <oasis:entry colname="col4">No files</oasis:entry>
         <oasis:entry colname="col5">1.2</oasis:entry>
         <oasis:entry colname="col6">No files</oasis:entry>
         <oasis:entry colname="col7">0</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Total excluded</oasis:entry>
         <oasis:entry namest="col2" nameend="col3" align="center" colsep="1">19 % </oasis:entry>
         <oasis:entry namest="col4" nameend="col5" align="center" colsep="1">18 % </oasis:entry>
         <oasis:entry namest="col6" nameend="col7" align="center">16 % </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Spectra/days before filtering</oasis:entry>
         <oasis:entry namest="col2" nameend="col3" align="center" colsep="1"><inline-formula><mml:math id="M405" display="inline"><mml:mrow><mml:mn mathvariant="normal">4773</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">720</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col4" nameend="col5" align="center" colsep="1"><inline-formula><mml:math id="M406" display="inline"><mml:mrow><mml:mn mathvariant="normal">4768</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">718</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col6" nameend="col7" align="center"><inline-formula><mml:math id="M407" display="inline"><mml:mrow><mml:mn mathvariant="normal">4585</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">714</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Spectra/days after filtering</oasis:entry>
         <oasis:entry namest="col2" nameend="col3" align="center" colsep="1"><inline-formula><mml:math id="M408" display="inline"><mml:mrow><mml:mn mathvariant="normal">3864</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">678</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col4" nameend="col5" align="center" colsep="1"><inline-formula><mml:math id="M409" display="inline"><mml:mrow><mml:mn mathvariant="normal">3912</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">664</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry namest="col6" nameend="col7" align="center"><inline-formula><mml:math id="M410" display="inline"><mml:mrow><mml:mn mathvariant="normal">3855</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">663</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e7802">Legend for the rows of Table <xref ref-type="table" rid="App1.Ch1.S2.T7"/>:
<list list-type="order"><list-item>
      <p id="d1e7809">Systematic error (mean plus 2 SD)</p></list-item><list-item>
      <p id="d1e7813">Random error (mean plus 2 SD)</p></list-item><list-item>
      <p id="d1e7817">Residual (<inline-formula><mml:math id="M411" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) (mean plus 2 SD)</p></list-item><list-item>
      <p id="d1e7832">DFS (mean minus 2 SD)</p></list-item><list-item>
      <p id="d1e7836">To exclude noisy spectra and possible nonlinearity in measurements, we use only measurements with SNR values ranging from 50 (60) to 600.</p></list-item><list-item>
      <p id="d1e7840">Not converged</p></list-item><list-item>
      <p id="d1e7844">Divergence warning</p></list-item><list-item>
      <p id="d1e7848">SFIT4 did not present results</p></list-item></list></p><?xmltex \hack{\clearpage}?>
</app>
  </app-group><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e7856">The FTIR CFC-11, CFC-12, and HCFC-22 retrievals at the St. Petersburg site are available from the NDACC database at <uri>https://www-air.larc.nasa.gov/missions/ndacc/data.html</uri> (last access: 29 July 2021; <xref ref-type="bibr" rid="bib1.bibx32" id="altparen.73"/>).
Mace Head site measurement data of CFC-11, CFC-12, and HCFC-22 were provided by the National Oceanicand Atmospheric Administration (NOAA)/Global Monitoring Division (GMD) in Boulder, CO, and are available at
<uri>ftp://ftp.cmdl.noaa.gov/hats/hcfcs/hcfc22/flasks/HCFC22_GCMS_flask.txt</uri> (last access: 28 June 2021; <xref ref-type="bibr" rid="bib1.bibx27" id="altparen.74"/>),
<uri>ftp://ftp.cmdl.noaa.gov/hats/cfcs/cfc11/flasks/GCMS/CFC11b_GCMS_flask.txt</uri> (last access: 28 June 2021; <xref ref-type="bibr" rid="bib1.bibx25" id="altparen.75"/>), and <uri>ftp://ftp.cmdl.noaa.gov/hats/cfcs/cfc12/flasks/GCMS/CFC12_GCMS_flask.txt</uri> (last access: 28 June 2021; <xref ref-type="bibr" rid="bib1.bibx26" id="altparen.76"/>).
ACE-FTS data are available from <ext-link xlink:href="https://doi.org/10.20383/101.0291" ext-link-type="DOI">10.20383/101.0291</ext-link> (<xref ref-type="bibr" rid="bib1.bibx3" id="altparen.77"/>; <xref ref-type="bibr" rid="bib1.bibx5" id="altparen.78"/>). WACCM profiles are interpolated to the St. Petersburg site location from the adoption of the WACCM V6 <xref ref-type="bibr" rid="bib1.bibx10" id="paren.79"/> model output in the framework of the NDACC observational program and are available at <uri>ftp://nitrogen.acom.ucar.edu/user/jamesw/IRWG/2013/WACCM/V6</uri> (last access: 19 June 2021; <xref ref-type="bibr" rid="bib1.bibx17" id="altparen.80"/>).</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e7906">YT originally proposed a general research topic. AlP, AnP, MM and YV were responsible for conceptualization. AlP developed techniques; created additional software; made calculations; analyzed, validated, and visualized results; and wrote the original draft. AnP and MM were responsible for the measurements of solar radiation. YV was responsible for the water vapor profiles retrievals. AnP performed measurements of spectral sensitivity functions and detected the effects of water ice. AN made some additional calculations and visualized the results. AlP and YV prepared and edited the article.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e7912">The authors declare that they have no conflict of interest.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e7918">Publisher’s note: Copernicus Publications remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e7924">The initial study was supported by the Russian Foundation for Basic Research. The revision of the paper, including additional calculations of the CFC-11 TCs and analysis of the contribution of various parameters to spectral measurements by Bruker 125HR at the St. Petersburg site, was performed in the Ozone Layer and Upper Atmosphere Research Laboratory of St. Petersburg State University (SPbU). The ACE mission is funded by the Canadian Space Agency. We thank James W. Hannigan​​​​​​​ (National Center for Atmospheric Research – NCAR; Boulder, CO, USA) for providing the data of the WACCM model at the NDACC station in St. Petersburg. The ground-based TCs measurements of solar radiation at the St. Petersburg site were obtained using the equipment of the SPbU Center for Geo-Environmental Research and Modeling (GEOMODEL).</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e7929">This research has been supported by the Russian Foundation for Basic Research (grant no. 18-05-00426) and the Ministry of Science and Higher Education of the Russian Federation (grant no. 075-15-2021-583).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e7935">This paper was edited by Justus Notholt and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><?xmltex \def\ref@label{AER(2017)}?><label>AER(2017)</label><?label MT_CKD?><mixed-citation>Atmospheric and Environmental Research R&amp;C (AER): Continuum Model MT_CKD_3.2 [code], available at: <uri>http://rtweb.aer.com/continuum_code.html</uri> (last access: 19 April 2019), 2017.</mixed-citation></ref>
      <ref id="bib1.bibx2"><?xmltex \def\ref@label{Bernath et al.(2020a)}?><label>Bernath et al.(2020a)</label><?label Bernath2020?><mixed-citation>Bernath, P. F., Steffen, J., Crouse J., and Boone C. D.: Sixteen-year trends in atmospheric trace gases from orbit, J. Quant. Spectrosc. Ra., 253, 107178,
<ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2020.107178" ext-link-type="DOI">10.1016/j.jqsrt.2020.107178</ext-link>, 2020a.</mixed-citation></ref>
      <ref id="bib1.bibx3"><?xmltex \def\ref@label{Bernath et al.(2020b)}?><label>Bernath et al.(2020b)</label><?label Bernathdata2020b?><mixed-citation>Bernath, P., Steffen, J., Crouse, J., and Boone, C.: Atmospheric Chemistry Experiment SciSat Level 2 Processed Data, v4.0, Federated Research Data Repository [data set], <ext-link xlink:href="https://doi.org/10.20383/101.0291" ext-link-type="DOI">10.20383/101.0291</ext-link>, 2020b.</mixed-citation></ref>
      <ref id="bib1.bibx4"><?xmltex \def\ref@label{Blumenstock et al.(2020)}?><label>Blumenstock et al.(2020)</label><?label Blumenstock2020?><mixed-citation>Blumenstock, T., Hase, F., Keens, A., Czurlok, D., Colebatch, O., Garcia, O., Griffith, D. W. T., Grutter, M., Hannigan, J. W., Heikkinen, P., Jeseck, P., Jones, N., Kivi, R., Lutsch, E., Makarova, M., Imhasin, H. K., Mellqvist, J., Morino, I., Nagahama, T., Notholt, J., Ortega, I., Palm, M., Raffalski, U., Rettinger, M., Robinson, J., Schneider, M., Servais, C., Smale, D., Stremme, W., Strong, K., Sussmann, R., Té, Y., and Velazco, V. A.: Characterization and potential for reducing optical resonances in Fourier transform infrared spectrometers of the Network for the Detection of Atmospheric Composition Change (NDACC), Atmos. Meas. Tech., 14, 1239–1252, <ext-link xlink:href="https://doi.org/10.5194/amt-14-1239-2021" ext-link-type="DOI">10.5194/amt-14-1239-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx5"><?xmltex \def\ref@label{Boone et al.(2020)}?><label>Boone et al.(2020)</label><?label Boone2020?><mixed-citation>Boone, C. D., Bernath, P. F., Cok, D., Jones, S. C., and Steffen, J.: Version 4 retrievals for the atmospheric chemistry experiment Fourier transform spectrometer (ACE-FTS) and imagers, J. Quant. Spectrosc. Ra., 247, 106939, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2020.106939" ext-link-type="DOI">10.1016/j.jqsrt.2020.106939</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx6"><?xmltex \def\ref@label{Brown et al.(2011)}?><label>Brown et al.(2011)</label><?label Brown2011?><mixed-citation>Brown, A. T., Chipperfield, M. P., Boone, C., Wilson, C., Walker, K. A., and
Bernath, P. F.: Trends in atmospheric halogen containing gases since 2004,
J. Quant. Spectrosc. Ra., 112, 2552–2566, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2011.07.005" ext-link-type="DOI">10.1016/j.jqsrt.2011.07.005</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx7"><?xmltex \def\ref@label{Cracknell and Varotsos(2009)}?><label>Cracknell and Varotsos(2009)</label><?label Cracknell2009?><mixed-citation>Cracknell, A. P. and Varotsos, C. A.: The contribution of remote sensing to
the implementation of the Montreal Protocol and the monitoring of its success, Int. J. Remote Sens., 30, 3853–3873, <ext-link xlink:href="https://doi.org/10.1080/01431160902821999" ext-link-type="DOI">10.1080/01431160902821999</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx8"><?xmltex \def\ref@label{Dunse et al.(2005)}?><label>Dunse et al.(2005)</label><?label Dunse2005?><mixed-citation>Dunse, B. L., Steele, V., Wilson, S. R., Fraser, P. J., and Krummel, P. B.: Trace gas emissions from Melbourne, Australia, based on AGAGE observations at Cape Grim, Tasmania, 1995–2000, Atmos. Environ., 39, 6334–6344, <ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2005.07.014" ext-link-type="DOI">10.1016/j.atmosenv.2005.07.014</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bibx9"><?xmltex \def\ref@label{Eckert et al.(2016)}?><label>Eckert et al.(2016)</label><?label Eckert2016?><mixed-citation>Eckert, E., Laeng, A., Lossow, S., Kellmann, S., Stiller, G., von Clarmann, T., Glatthor, N., Höpfner, M., Kiefer, M., Oelhaf, H., Orphal, J., Funke, B., Grabowski, U., Haenel, F., Linden, A., Wetzel, G., Woiwode, W., Bernath, P. F., Boone, C., Dutton, G. S., Elkins, J. W., Engel, A., Gille, J. C., Kolonjari, F., Sugita, T., Toon, G. C., and Walker, K. A.: MIPAS IMK/IAA CFC-11 (CCl<inline-formula><mml:math id="M412" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>F) and CFC-12<?pagebreak page5366?> (CCl<inline-formula><mml:math id="M413" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>F<inline-formula><mml:math id="M414" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) measurements: accuracy, precision and long-term stability, Atmos. Meas. Tech., 9, 3355–3389, <ext-link xlink:href="https://doi.org/10.5194/amt-9-3355-2016" ext-link-type="DOI">10.5194/amt-9-3355-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx10"><?xmltex \def\ref@label{Garcia et al.(2007)}?><label>Garcia et al.(2007)</label><?label Garcia2007?><mixed-citation>Garcia, R. R., Marsh,  D. R., Kinnison, D. E., Boville, B. A., and Sassi F.: Simulation of secular trends in the middle atmosphere, 1950–2003, J. Geophys. Res., 112, D09301, <ext-link xlink:href="https://doi.org/10.1029/2006JD007485" ext-link-type="DOI">10.1029/2006JD007485</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx11"><?xmltex \def\ref@label{Gardiner et al.(2008)}?><label>Gardiner et al.(2008)</label><?label Gardiner2008?><mixed-citation>Gardiner, T., Forbes, A., de Mazière, M., Vigouroux, C., Mahieu, E., Demoulin, P., Velazco, V., Notholt, J., Blumenstock, T., Hase, F., Kramer, I., Sussmann, R., Stremme, W., Mellqvist, J., Strandberg, A., Ellingsen, K., and Gauss, M.: Trend analysis of greenhouse gases over Europe measured by a network of ground-based remote FTIR instruments, Atmos. Chem. Phys., 8, 6719–6727, <ext-link xlink:href="https://doi.org/10.5194/acp-8-6719-2008" ext-link-type="DOI">10.5194/acp-8-6719-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx12"><?xmltex \def\ref@label{Goldman et al.(1981)}?><label>Goldman et al.(1981)</label><?label Goldman1981?><mixed-citation>
Goldman, A., Murcray, F. J., Blatherwick, R. D., Bonomo, F. S., Murcray, F. H., and Murcray, D. G.: Spectroscopic identification of CHClF2 (F-22) in the lower stratosphere, Geophys. Res. Lett., 8, 1012–1014, 1981.</mixed-citation></ref>
      <ref id="bib1.bibx13"><?xmltex \def\ref@label{Hase et al.(2004)}?><label>Hase et al.(2004)</label><?label Hase2004?><mixed-citation>
Hase, F., Hannigan, J. W., Coffey, M. T., Goldman, A., Höpfner, M.,
Jones, N. B., and Rinsland, C. P., Wood, S. W.: Intercomparison of retrieval codes used for the analysis of high-resolution, ground-based FTIR measurements, J. Quant. Spectrosc. Ra., 87, 25–52, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx14"><?xmltex \def\ref@label{Hoffmann and Riese(2004)}?><label>Hoffmann and Riese(2004)</label><?label Hoffmann2004?><mixed-citation>
Hoffmann, L. and Riese, M.: Quantitative transport studies based on trace gas
assimilation, Adv. Space Res., 33, 1068–1072,
doi:10.1016/S0273-1177(03)00592-1, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx15"><?xmltex \def\ref@label{Hoffmann et al.(2008)}?><label>Hoffmann et al.(2008)</label><?label Hoffmann2008?><mixed-citation>Hoffmann, L., Kaufmann, M., Spang, R., Müller, R., Remedios, J. J., Moore, D. P., Volk, C. M., von Clarmann, T., and Riese, M.: Envisat MIPAS measurements of CFC-11: retrieval, validation, and climatology, Atmos. Chem. Phys., 8, 3671–3688, <ext-link xlink:href="https://doi.org/10.5194/acp-8-3671-2008" ext-link-type="DOI">10.5194/acp-8-3671-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx16"><?xmltex \def\ref@label{Hudgins et al.(1993)}?><label>Hudgins et al.(1993)</label><?label Hudgins1993?><mixed-citation>Hudgins, D. M., Sandford, S. A., Allamandola, L. J., and Tielens, A. G. G. M.: Mid- and Far-Infrared Spectroscopy of Ices: Optical Constants and
Integrated Absorbances,  Astrophys. J. Suppl. S., 86, 713–870,
<ext-link xlink:href="https://doi.org/10.1086/191796" ext-link-type="DOI">10.1086/191796</ext-link>, 1993.</mixed-citation></ref>
      <ref id="bib1.bibx17"><?xmltex \def\ref@label{IRWG-NDACC(2021)}?><label>IRWG-NDACC(2021)</label><?label IRWG-NDACC2021?><mixed-citation>IRWG-NDACC: WACCM V.6 profiles dataset for IRWG sites, NDACC Infrared Working Group, available at: <uri>ftp://nitrogen.acom.ucar.edu/user/jamesw/IRWG/2013/WACCM/V6</uri>, last access: 19 June 2021.</mixed-citation></ref>
      <ref id="bib1.bibx18"><?xmltex \def\ref@label{Kellmann et al.(2012)}?><label>Kellmann et al.(2012)</label><?label Kellmann2012?><mixed-citation>Kellmann, S., von Clarmann, T., Stiller, G. P., Eckert, E., Glatthor, N., Höpfner, M., Kiefer, M., Orphal, J., Funke, B., Grabowski, U., Linden, A., Dutton, G. S., and Elkins, J. W.: Global CFC-11 (CCl<inline-formula><mml:math id="M415" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>F) and CFC-12 (CCl<inline-formula><mml:math id="M416" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>F<inline-formula><mml:math id="M417" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) measurements with the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS): retrieval, climatologies and trends, Atmos. Chem. Phys., 12, 11857–11875, <ext-link xlink:href="https://doi.org/10.5194/acp-12-11857-2012" ext-link-type="DOI">10.5194/acp-12-11857-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx19"><?xmltex \def\ref@label{Khosrawi et al.(2004)}?><label>Khosrawi et al.(2004)</label><?label Khosrawi2004?><mixed-citation>Khosrawi, F., Müller, R., Irie, H., Engel, A., Toon, G., Sen, B., Aoki, S.,
Nakazawa, T., Traub, W., and Jucks, K. J.: Validation of CFC-12 measurements
from the Improved Limb Atmospheric Spectrometer (ILAS) with the version 6.0
retrieval algorithm, J. Geophys. Res., 109, D06311,
<ext-link xlink:href="https://doi.org/10.1029/2003JD004325" ext-link-type="DOI">10.1029/2003JD004325</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx20"><?xmltex \def\ref@label{Lynch(2006)}?><label>Lynch(2006)</label><?label Lynch2006?><mixed-citation>
Lynch, D. K.: The Infrared Spectral Signature of Water Ice in the Vacuum
Cryogenic AI&amp;T Environment, Aerospace Report No. TR-2006(8570)-1, The Aerospace Corporation Laboratory Operations, El Segundo, Los Angeles Air Force Base, CA, USA, 19 pp., 2006.</mixed-citation></ref>
      <ref id="bib1.bibx21"><?xmltex \def\ref@label{Mahieu et al.(2013)}?><label>Mahieu et al.(2013)</label><?label Mahieu2013?><mixed-citation>
Mahieu, E., O’Doherty, S., Reimann, S., Vollmer, M., Bader, W., Bovy, B.,
Lejeune, B., Demoulin, P., Roland G., and Servais, C.: First retrievals of
HCFC-142b from ground-based high-resolution FTIR solar observations:
application to high-altitude Jungfraujoch spectra, EGU General Assembly, Vienna, Austria, 7–12 April 2013, EGU2013-1185-1, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx22"><?xmltex \def\ref@label{Mahieu et al.(2008)}?><label>Mahieu et al.(2008)</label><?label Mahieu2008?><mixed-citation>Mahieu, E., Duchatelet, P., Demoulin, P., Walker, K. A., Dupuy, E., Froidevaux, L., Randall, C., Catoire, V., Strong, K., Boone, C. D., Bernath, P. F., Blavier, J.-F., Blumenstock, T., Coffey, M., De Mazière, M., Griffith, D., Hannigan, J., Hase, F., Jones, N., Jucks, K. W., Kagawa, A., Kasai, Y., Mebarki, Y., Mikuteit, S., Nassar, R., Notholt, J., Rinsland, C. P., Robert, C., Schrems, O., Senten, C., Smale, D., Taylor, J., Tétard, C., Toon, G. C., Warneke, T., Wood, S. W., Zander, R., and Servais, C.: Validation of ACE-FTS v2.2 measurements of HCl, HF, CCl<inline-formula><mml:math id="M418" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>F and CCl<inline-formula><mml:math id="M419" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>F<inline-formula><mml:math id="M420" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> using space-, balloon- and ground-based instrument observations, Atmos. Chem. Phys., 8, 6199–6221, <ext-link xlink:href="https://doi.org/10.5194/acp-8-6199-2008" ext-link-type="DOI">10.5194/acp-8-6199-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx23"><?xmltex \def\ref@label{Mahieu et al.(2017)}?><label>Mahieu et al.(2017)</label><?label Mahieu2017?><mixed-citation>Mahieu, E., Lejeune, B., Bovy, B., Servais, C., Toon, G. C., Bernath, P. F.,
Boone, C. D., Walker, K. A., Reimann, S., and Vollmer, M. K.: Retrieval of
HCFC-142b (CH<inline-formula><mml:math id="M421" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>CClF<inline-formula><mml:math id="M422" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>) from ground-based high–resolution infrared solar spectra: Atmospheric increase since 1989 and comparison with surface and satellite measurements, J. Quant. Spectrosc. Ra., 186, 96–105, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx24"><?xmltex \def\ref@label{Mahieu et al.(2010)}?><label>Mahieu et al.(2010)</label><?label Mahieu2010?><mixed-citation>
Mahieu, E., Rinsland, C. P., Gardiner, T., Zander, R., Demoulin, P., Chipperfield, M. P., Ruhnke, R., Chiou, L. S., De Mazière, M., and the GIRPAS Team: Recent trends of inorganic chlorine and halogenated source gases abovethe Jungfraujoch and Kitt Peak stations derived from high-resolution FTIR solar observations, EGU General Assembly, Vienna, Austria, 2–7 May 2010, EGU2010-2420-3, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx25"><?xmltex \def\ref@label{MHD CFC-11 data(2021)}?><label>MHD CFC-11 data(2021)</label><?label MHDCFC-11data2021?><mixed-citation>MHD CFC-11 data: Mace Head site measurement data of CFC-11, National Oceanicand Atmospheric Administration (NOAA)/Global Monitoring Division
(GMD) in Boulder CO, available at: <uri>ftp://ftp.cmdl.noaa.gov/hats/cfcs/cfc11/flasks/GCMS/CFC11b_GCMS_flask.txt</uri>, last access: 28 June 2021.</mixed-citation></ref>
      <ref id="bib1.bibx26"><?xmltex \def\ref@label{MHD CFC-12 data(2021)}?><label>MHD CFC-12 data(2021)</label><?label MHDCFC-12data2021?><mixed-citation>MHD CFC-12 data: Mace Head site measurement data of CFC-12, National Oceanicand Atmospheric Administration (NOAA)/Global Monitoring Division
(GMD) in Boulder CO, available at: <uri>ftp://ftp.cmdl.noaa.gov/hats/cfcs/cfc12/flasks/GCMS/CFC12_GCMS_flask.txt</uri>, last access: 28 June 2021.</mixed-citation></ref>
      <ref id="bib1.bibx27"><?xmltex \def\ref@label{MHD HCFC-22 data(2021)}?><label>MHD HCFC-22 data(2021)</label><?label MHDHCFC-22data2021?><mixed-citation>MHD HCFC-22 data: Mace Head site measurement data of HCFC-22, National Oceanicand Atmospheric Administration (NOAA)/Global Monitoring Division
(GMD) in Boulder CO, available at: <uri>ftp://ftp.cmdl.noaa.gov/hats/hcfcs/hcfc22/flasks/HCFC22_GCMS_flask.txt</uri>, last access: 28 June 2021.</mixed-citation></ref>
      <ref id="bib1.bibx28"><?xmltex \def\ref@label{Mlawer et al.(2012)}?><label>Mlawer et al.(2012)</label><?label Mlawer2012?><mixed-citation>Mlawer, E. J., Payne, V. H., Moncet, J. L., Delamere, J. S., Alvarado, M. J.,
Tobin, D. D.: Development and recent evaluation of the MT_CKD model of
continuum absorption, Philos. T. R. Soc. A, 370, 2520–2556,
<ext-link xlink:href="https://doi.org/10.1098/rsta.2011.0295" ext-link-type="DOI">10.1098/rsta.2011.0295</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx29"><?xmltex \def\ref@label{Molina and Rowland(1974)}?><label>Molina and Rowland(1974)</label><?label Molina1974?><mixed-citation>Molina, M. and Rowland, F.: Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone, Nature, 249, 810–812,
<ext-link xlink:href="https://doi.org/10.1038/249810a0" ext-link-type="DOI">10.1038/249810a0</ext-link>, 1974.</mixed-citation></ref>
      <ref id="bib1.bibx30"><?xmltex \def\ref@label{Montzka et al.(1993)}?><label>Montzka et al.(1993)</label><?label Montzka1993?><mixed-citation>Montzka, S. A., Myers, R. C., Butler, J. H., Elkins, J. W., and Cummings, S. O.: Global tropospheric distribution and calibration scale of HCFC-22, Geophys. Res. Lett., 20, 703–706, <ext-link xlink:href="https://doi.org/10.1029/93GL00753" ext-link-type="DOI">10.1029/93GL00753</ext-link>, 1993.</mixed-citation></ref>
      <?pagebreak page5367?><ref id="bib1.bibx31"><?xmltex \def\ref@label{Montzka et al.(2018)}?><label>Montzka et al.(2018)</label><?label Montzka2018?><mixed-citation>Montzka, S. A., Dutton, G. S., Yu, P., Ray, E., Portmann, R. W., Daniel J. S., Kuijpers, L., Hall, B. D., Mondeel, D., Siso, C., Nance, J. D., Rigby, M., Manning, A. J., Hu, L.,  Moore, F., Miller, B. R., and Elkins, J. W.:  An unexpected and persistent increase in global emissions of ozone–depleting CFC-11, Nature, 557, 413–417, <ext-link xlink:href="https://doi.org/10.1038/s41586-018-0106-2" ext-link-type="DOI">10.1038/s41586-018-0106-2</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx32"><?xmltex \def\ref@label{NDACC(2021)}?><label>NDACC(2021)</label><?label NDACC2021?><mixed-citation>Network for the Detection of Atmospheric Composition Change (NDACC): NDACC public data archive, available at: <uri>https://www-air.larc.nasa.gov/missions/ndacc/data.html</uri>, last access: 29 July 2021.</mixed-citation></ref>
      <ref id="bib1.bibx33"><?xmltex \def\ref@label{Notholt(1994)}?><label>Notholt(1994)</label><?label Notholt1994?><mixed-citation>Notholt, J.: FTIR measurements of HF, N<inline-formula><mml:math id="M423" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O and CFCs during the Arctic polar
night with the Moon as light source, subsidence during winter 1992/93,
Geophys. Res. Lett., 21, 2385–2388, <ext-link xlink:href="https://doi.org/10.1029/94GL02351" ext-link-type="DOI">10.1029/94GL02351</ext-link>, 1994.</mixed-citation></ref>
      <ref id="bib1.bibx34"><?xmltex \def\ref@label{Park et al.(2013)}?><label>Park et al.(2013)</label><?label Park2013?><mixed-citation>Park, M., Randel, W. J., Kinnison, D. E., Emmons, L. K., Bernath, P. F.,
Walker, K. A., Boone, C. D., and Livesey, M. J.: Hydrocarbons in the upper
troposphere and lower stratosphere observed from ACE-FTS and comparisons
with WACCM, J. Geophys. Res.-Atmos., 118, 1964–1980,
<ext-link xlink:href="https://doi.org/10.1029/2012JD018327" ext-link-type="DOI">10.1029/2012JD018327</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx35"><?xmltex \def\ref@label{Phillips(1962)}?><label>Phillips(1962)</label><?label Phillips1962?><mixed-citation>Phillips, D.: A technique for the numerical solution of certain integral
equations of the first kind, J. ACM, 9, 84–97, <ext-link xlink:href="https://doi.org/10.1145/321105.321114" ext-link-type="DOI">10.1145/321105.321114</ext-link>, 1962.</mixed-citation></ref>
      <ref id="bib1.bibx36"><?xmltex \def\ref@label{Polyakov et al.(2020a)}?><label>Polyakov et al.(2020a)</label><?label Polyakov2020b?><mixed-citation>Polyakov, A., Virolainen, Y., Poberovskiy, A., Makarova, M., and Timofeyev, Y.: Atmospheric HCFC-22 total columns near St. Petersburg: stabilization with
start of a decrease, Int. J. Rem. Sens., 41, 4365–4371, <ext-link xlink:href="https://doi.org/10.1080/01431161.2020.1717668" ext-link-type="DOI">10.1080/01431161.2020.1717668</ext-link>, 2020a.</mixed-citation></ref>
      <ref id="bib1.bibx37"><?xmltex \def\ref@label{Polyakov et al.(2018)}?><label>Polyakov et al.(2018)</label><?label Polyakov2018?><mixed-citation>Polyakov, A. V., Timofeyev, Y. M., Virolainen, Y. A., Makarova, M. V.,
Poberovskii, A. V., and Imhasin, H. K.: Ground-Based Measurements of the
Total Column of Freons in the Atmosphere near St. Petersburg (2009–2017),
Izv. Atmos. Ocean. Phy., 54, 487–494, <ext-link xlink:href="https://doi.org/10.1134/S0001433818050109" ext-link-type="DOI">10.1134/S0001433818050109</ext-link>,
2018.</mixed-citation></ref>
      <ref id="bib1.bibx38"><?xmltex \def\ref@label{Polyakov et al.(2019a)}?><label>Polyakov et al.(2019a)</label><?label Polyakov2019a?><mixed-citation>Polyakov, A. V., Virolainen, Y. A., and Makarova, M. V.: Technique for Inverting Transmission Spectra to Measure Freon Concentration, J. Appl. Spectrosc., 85, 1085–1093, <ext-link xlink:href="https://doi.org/10.1007/s10812-019-00763-y" ext-link-type="DOI">10.1007/s10812-019-00763-y</ext-link>, 2019a.</mixed-citation></ref>
      <ref id="bib1.bibx39"><?xmltex \def\ref@label{Polyakov et al.(2019b)}?><label>Polyakov et al.(2019b)</label><?label Polyakov2019b?><mixed-citation>Polyakov, A. V., Virolainen, Y. A., and Makarova M. V.: Method For Inversion Of The Transparency Spectra For Evaluating The Content of CCl<inline-formula><mml:math id="M424" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>F<inline-formula><mml:math id="M425" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> In The
Atmosphere, J. Appl. Spectrosc., 86, 449–456, <ext-link xlink:href="https://doi.org/10.1007/s10812-019-00840-2" ext-link-type="DOI">10.1007/s10812-019-00840-2</ext-link>, 2019b.</mixed-citation></ref>
      <ref id="bib1.bibx40"><?xmltex \def\ref@label{Polyakov et al.(2020b)}?><label>Polyakov et al.(2020b)</label><?label Polyakov2020a?><mixed-citation>Polyakov, A. V., Poberovsky, A. V., Virolainen, Y. A., and Makarova M. V.:
Transparency Spectra Inversion Technique for Evaluating the Atmospheric
Content of CCl<inline-formula><mml:math id="M426" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>F freon, J. Appl. Spectrosc., 87, 92–98, <ext-link xlink:href="https://doi.org/10.1007/s10812-020-00968-6" ext-link-type="DOI">10.1007/s10812-020-00968-6</ext-link>, 2020b.</mixed-citation></ref>
      <ref id="bib1.bibx41"><?xmltex \def\ref@label{Prignon et al.(2019)}?><label>Prignon et al.(2019)</label><?label Prignon2019?><mixed-citation>Prignon, M., Chabrillat, S., Minganti, D., O'Doherty, S., Servais, C., Stiller, G., Toon, G. C., Vollmer, M. K., and Mahieu, E.: Improved FTIR retrieval strategy for HCFC-22 (CHClF<inline-formula><mml:math id="M427" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>), comparisons with in situ and satellite datasets with the support of models, and determination of its long-term trend above Jungfraujoch, Atmos. Chem. Phys., 19, 12309–12324, <ext-link xlink:href="https://doi.org/10.5194/acp-19-12309-2019" ext-link-type="DOI">10.5194/acp-19-12309-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx42"><?xmltex \def\ref@label{Rinsland et al.(2005)}?><label>Rinsland et al.(2005)</label><?label Rinsland2005?><mixed-citation>
Rinsland, C. P., Chiou, L. S., Goldman, A., and Wood, S. W.:
Long-term trend in CHF2Cl (HCFC-22) from high spectral resolution infrared
solar absorption measurements and comparisons with in situ measurements,
J. Quant. Spectrosc. Ra., 90, 367–375, 2005</mixed-citation></ref>
      <ref id="bib1.bibx43"><?xmltex \def\ref@label{Rinsland et al.(2010)}?><label>Rinsland et al.(2010)</label><?label Rinsland2010?><mixed-citation>
Rinsland, C. P., Chiou, L., Goldman, A., and Hannigan, J. W.: Multi-decade
measurements of the long-term trends of atmospheric species by
high-spectral-resolution infrared solar absorption spectroscopy,
J. Quant. Spectrosc. Ra., 111, 376–383, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx44"><?xmltex \def\ref@label{Rodgers(2000)}?><label>Rodgers(2000)</label><?label Rodgers2000?><mixed-citation>Rodgers, C. D.: Inverse Methods for Atmospheric Sounding: Theory and
Practice, in: Series on Atmospheric, Oceanic and Planetary Physics: Volume 2,
World Scientific Publishing, Singapore, 238 pp., <ext-link xlink:href="https://doi.org/10.1142/3171" ext-link-type="DOI">10.1142/3171</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx45"><?xmltex \def\ref@label{Rodgers and Connor(2003)}?><label>Rodgers and Connor(2003)</label><?label Rodgers2003?><mixed-citation>Rodgers, C. D. and Connor, B. J.: Intercomparison of remote sounding
instruments, J. Geophys. Res., 108, 4116, <ext-link xlink:href="https://doi.org/10.1029/2002JD002299" ext-link-type="DOI">10.1029/2002JD002299</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bibx46"><?xmltex \def\ref@label{Santer et al.(2000)}?><label>Santer et al.(2000)</label><?label Santer2000?><mixed-citation>Santer, B. D., Wigley, T. M. L., Boyle, J. S., Gaffen, D. J., Hnilo, J. J., Nychka, D., Parker, D. E., and Taylor, K. E.: Statistical significance of trends and trend differences in layeraverage atmospheric temperature time series, J. Geophys. Res., 105, 7337–7356, <ext-link xlink:href="https://doi.org/10.1029/1999JD901105" ext-link-type="DOI">10.1029/1999JD901105</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx47"><?xmltex \def\ref@label{Senten et al.(2012)}?><label>Senten et al.(2012)</label><?label Senten2012?><mixed-citation>Senten, C., De Mazière, M., Vanhaelewyn, G., and Vigouroux, C.: Information operator approach applied to the retrieval of the vertical distribution of atmospheric constituents from ground-based high-resolution FTIR measurements, Atmos. Meas. Tech., 5, 161–180, <ext-link xlink:href="https://doi.org/10.5194/amt-5-161-2012" ext-link-type="DOI">10.5194/amt-5-161-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx48"><?xmltex \def\ref@label{Solomon et al.(2014)}?><label>Solomon et al.(2014)</label><?label Solomon2014?><mixed-citation>
Solomon, S., Haskins, J., Ivy, D., and Min, F.: Fundamental differences
between Arctic and Antarctic ozone depletion, P. Natl. Acad. Sci. USA, 111,
6220–6225, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx49"><?xmltex \def\ref@label{Sussmann et al.(2011)}?><label>Sussmann et al.(2011)</label><?label Sussmann2011?><mixed-citation>Sussmann, R., Forster, F., Rettinger, M., and Jones, N.: Strategy for high-accuracy-and-precision retrieval of atmospheric methane from the mid-infrared FTIR network, Atmos. Meas. Tech., 4, 1943–1964, <ext-link xlink:href="https://doi.org/10.5194/amt-4-1943-2011" ext-link-type="DOI">10.5194/amt-4-1943-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx50"><?xmltex \def\ref@label{Tikhonov(1963)}?><label>Tikhonov(1963)</label><?label Tikhonov1963?><mixed-citation>
Tikhonov, A., On the solution of incorrectly stated problems and a method
of regularization, Dokl. Akad. Nauk SSSR, 151, 501–504, 1963.</mixed-citation></ref>
      <ref id="bib1.bibx51"><?xmltex \def\ref@label{Timofeyev et al.(2016)}?><label>Timofeyev et al.(2016)</label><?label Timofeyev2016?><mixed-citation>
Timofeyev Yu., Virolainen, Ya., Makarova, M., Poberovsky, A., Polyakov, A.,
Ionov, D., Osipov, S., and Imhasin, H.: Ground-based spectroscopic measurements of atmospheric gas composition near Saint Petersburg (Russia), J. Mol. Spectrosc., 323, 2–14, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx52"><?xmltex \def\ref@label{Timofeev et al.(2020)}?><label>Timofeev et al.(2020)</label><?label Timofeev2020?><mixed-citation>
Timofeev, Yu. M., Polyakov, A. V., Virolainen, Ya. A., Makarova, M. V., Ionov, D. V., Poberovsky, A. V., and Imhasin, H. H.: Estimates of Trends of Climatically Important Atmospheric Gases Near St. Petersburg, Izv. Atmos. Ocean. Phy., 56, 79–84, 2020b.</mixed-citation></ref>
      <ref id="bib1.bibx53"><?xmltex \def\ref@label{Virolainen et al.(2017)}?><label>Virolainen et al.(2017)</label><?label Virolainen2017?><mixed-citation>Virolainen, Y. A., Timofeyev, Y. M., Kostsov, V. S., Ionov, D. V., Kalinnikov, V. V., Makarova, M. V., Poberovsky, A. V., Zaitsev, N. A., Imhasin, H. H., Polyakov, A. V., Schneider, M., Hase, F., Barthlott, S., and Blumenstock, T.: Quality assessment of integrated water vapour measurements at the St. Petersburg site, Russia: FTIR vs. MW and GPS techniques, Atmos. Meas. Tech., 10, 4521–4536, <ext-link xlink:href="https://doi.org/10.5194/amt-10-4521-2017" ext-link-type="DOI">10.5194/amt-10-4521-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx54"><?xmltex \def\ref@label{WMO(1985)}?><label>WMO(1985)</label><?label WMO1985?><mixed-citation>
WMO (World Meteorological Organization): Atmospheric ozone 1985: assessment
of our understanding of the processes controlling its present distribution
and change, Global Ozone Research and Monitoring Project – Report
No. 16, WMO, Geneva, Switzerland, 588 pp., 1985.</mixed-citation></ref>
      <ref id="bib1.bibx55"><?xmltex \def\ref@label{WMO(2018)}?><label>WMO(2018)</label><?label WMO2018?><mixed-citation>
WMO (World Meteorological Organization): Scientific Assessment of Ozone
Depletion: 2018, Global Ozone Research and Monitoring Project – Report
No. 58, WMO, Geneva, Switzerland, 588 pp., 2018.</mixed-citation></ref>
      <ref id="bib1.bibx56"><?xmltex \def\ref@label{Yagovkina et al.(2011)}?><label>Yagovkina et al.(2011)</label><?label Yagovkina2011?><mixed-citation>Yagovkina, I. S., Polyakov, A. V., Poberovskii, A. V., and Timofeyev, Yu. M.: Spectroscopic measurements of total CFC-11 freon in the atmosphere near St. Petersburg, Izv. Atmos. Ocean. Phy., 47, 186–189, <ext-link xlink:href="https://doi.org/10.1134/S0001433811020125" ext-link-type="DOI">10.1134/S0001433811020125</ext-link>, 2011.</mixed-citation></ref>
      <?pagebreak page5368?><ref id="bib1.bibx57"><?xmltex \def\ref@label{Zander et al.(2005)}?><label>Zander et al.(2005)</label><?label Zander2005?><mixed-citation>Zander, R., Mahieu, E., Demoulin, P., Duchatelet, P., Servais, C., Roland, G., Delbouille, L., De Mazière, M., and Rinsland, C. P.: Evolution of a dozen
non-CO<inline-formula><mml:math id="M428" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> greenhouse gases above Central Europe since the mid-1980s, Environ. Sci., 2, 295–303, <ext-link xlink:href="https://doi.org/10.1080/15693430500397152" ext-link-type="DOI">10.1080/15693430500397152</ext-link>, 2005.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx58"><?xmltex \def\ref@label{Zhou et al.(2016)}?><label>Zhou et al.(2016)</label><?label Zhou2016?><mixed-citation>Zhou, M., Vigouroux, C., Langerock, B., Wang, P., Dutton, G., Hermans, C., Kumps, N., Metzger, J.-M., Toon, G., and De Mazière, M.: CFC-11, CFC-12 and HCFC-22 ground-based remote sensing FTIR measurements at Réunion Island and comparisons with MIPAS/ENVISAT data, Atmos. Meas. Tech., 9, 5621–5636, <ext-link xlink:href="https://doi.org/10.5194/amt-9-5621-2016" ext-link-type="DOI">10.5194/amt-9-5621-2016</ext-link>, 2016.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Measurements of CFC-11, CFC-12, and HCFC-22 total columns in the atmosphere at the St. Petersburg site in 2009–2019</article-title-html>
<abstract-html><p>Monitoring atmospheric anthropogenic halocarbons plays an important role in tracking their atmospheric concentrations in accordance with international agreements on emissions of ozone-depleting substances and, thus, in estimating the ozone layer recovery.</p><p>Within the Network for the Detection of Atmospheric Composition Change (NDACC), regular Fourier transform infrared (FTIR) measurements can provide information on the abundancies of halocarbons on a global scale. We improved retrieval strategies for deriving the CFC-11 (CCl<sub>3</sub>F), CFC-12 (CCl<sub>2</sub>F<sub>2</sub>), and HCFC-22 (CHClF<sub>2</sub>) atmospheric columns from IR solar radiation spectra measured by the Bruker IFS125HR spectrometer at the St. Petersburg site (Russia). We used the Tikhonov–Phillips regularization approach for solving the inverse problem with optimized values of regularization parameters. We tested the strategies developed by comparison of the FTIR measurements with independent data. The analysis of the time series of column-averaged dry air mole fractions (Xgas) measured in 2009–2019 gives mean values of 225&thinsp;pptv (parts per trillion by volume; CFC-11), 493&thinsp;pptv (CFC-12), and 238&thinsp;pptv (HCFC-22). Trend values total −0.40&thinsp;%&thinsp;yr<sup>−1</sup> (CFC-11), −0.49&thinsp;%&thinsp;yr<sup>−1</sup> (CFC-12), and 2.12&thinsp;%&thinsp;yr<sup>−1</sup> (HCFC-22).</p><p>We compared the means, trends, and seasonal variability in X<sub>CFC-11</sub>, X<sub>CFC-12</sub>, and X<sub>HCFC-22</sub> to that of (1) near-ground volume mixing ratios (VMRs), measured at the observational site Mace Head, Ireland (GVMR), (2) the mean in the 8–12&thinsp;km layer VMRs, measured by ACE-FTS and averaged over 55–65°&thinsp;N latitudes (SVMR), and (3) Xgas values of the Whole Atmosphere Community Climate Model (WACCM) for the St. Petersburg site (WXgas).</p><p>In general, the comparison of Xgas with the independent data showed a good agreement of their means within the systematic errors of the measurements
considered. The trends observed over the St. Petersburg site demonstrate the smaller decrease rates for X<sub>CFC-11</sub> and X<sub>CFC-12</sub> than that of the independent data and the same increase rate for X<sub>HCFC-22</sub>. As a whole, Xgas, SVMR, and WXgas showed qualitatively similar seasonal variations, while the GVMR variability is significantly less, and only the WX<sub>HCFC-22</sub> variations are essentially smaller than that of X<sub>HCFC-22</sub> and SVMR<sub>HCFC-22</sub>.</p></abstract-html>
<ref-html id="bib1.bib1"><label>AER(2017)</label><mixed-citation>
Atmospheric and Environmental Research R&amp;C (AER): Continuum Model MT_CKD_3.2 [code], available at: <a href="http://rtweb.aer.com/continuum_code.html" target="_blank"/> (last access: 19 April 2019), 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Bernath et al.(2020a)</label><mixed-citation>
Bernath, P. F., Steffen, J., Crouse J., and Boone C. D.: Sixteen-year trends in atmospheric trace gases from orbit, J. Quant. Spectrosc. Ra., 253, 107178,
<a href="https://doi.org/10.1016/j.jqsrt.2020.107178" target="_blank">https://doi.org/10.1016/j.jqsrt.2020.107178</a>, 2020a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Bernath et al.(2020b)</label><mixed-citation>
Bernath, P., Steffen, J., Crouse, J., and Boone, C.: Atmospheric Chemistry Experiment SciSat Level 2 Processed Data, v4.0, Federated Research Data Repository [data set], <a href="https://doi.org/10.20383/101.0291" target="_blank">https://doi.org/10.20383/101.0291</a>, 2020b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Blumenstock et al.(2020)</label><mixed-citation>
Blumenstock, T., Hase, F., Keens, A., Czurlok, D., Colebatch, O., Garcia, O., Griffith, D. W. T., Grutter, M., Hannigan, J. W., Heikkinen, P., Jeseck, P., Jones, N., Kivi, R., Lutsch, E., Makarova, M., Imhasin, H. K., Mellqvist, J., Morino, I., Nagahama, T., Notholt, J., Ortega, I., Palm, M., Raffalski, U., Rettinger, M., Robinson, J., Schneider, M., Servais, C., Smale, D., Stremme, W., Strong, K., Sussmann, R., Té, Y., and Velazco, V. A.: Characterization and potential for reducing optical resonances in Fourier transform infrared spectrometers of the Network for the Detection of Atmospheric Composition Change (NDACC), Atmos. Meas. Tech., 14, 1239–1252, <a href="https://doi.org/10.5194/amt-14-1239-2021" target="_blank">https://doi.org/10.5194/amt-14-1239-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Boone et al.(2020)</label><mixed-citation>
Boone, C. D., Bernath, P. F., Cok, D., Jones, S. C., and Steffen, J.: Version 4 retrievals for the atmospheric chemistry experiment Fourier transform spectrometer (ACE-FTS) and imagers, J. Quant. Spectrosc. Ra., 247, 106939, <a href="https://doi.org/10.1016/j.jqsrt.2020.106939" target="_blank">https://doi.org/10.1016/j.jqsrt.2020.106939</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Brown et al.(2011)</label><mixed-citation>
Brown, A. T., Chipperfield, M. P., Boone, C., Wilson, C., Walker, K. A., and
Bernath, P. F.: Trends in atmospheric halogen containing gases since 2004,
J. Quant. Spectrosc. Ra., 112, 2552–2566, <a href="https://doi.org/10.1016/j.jqsrt.2011.07.005" target="_blank">https://doi.org/10.1016/j.jqsrt.2011.07.005</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Cracknell and Varotsos(2009)</label><mixed-citation>
Cracknell, A. P. and Varotsos, C. A.: The contribution of remote sensing to
the implementation of the Montreal Protocol and the monitoring of its success, Int. J. Remote Sens., 30, 3853–3873, <a href="https://doi.org/10.1080/01431160902821999" target="_blank">https://doi.org/10.1080/01431160902821999</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Dunse et al.(2005)</label><mixed-citation>
Dunse, B. L., Steele, V., Wilson, S. R., Fraser, P. J., and Krummel, P. B.: Trace gas emissions from Melbourne, Australia, based on AGAGE observations at Cape Grim, Tasmania, 1995–2000, Atmos. Environ., 39, 6334–6344, <a href="https://doi.org/10.1016/j.atmosenv.2005.07.014" target="_blank">https://doi.org/10.1016/j.atmosenv.2005.07.014</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Eckert et al.(2016)</label><mixed-citation>
Eckert, E., Laeng, A., Lossow, S., Kellmann, S., Stiller, G., von Clarmann, T., Glatthor, N., Höpfner, M., Kiefer, M., Oelhaf, H., Orphal, J., Funke, B., Grabowski, U., Haenel, F., Linden, A., Wetzel, G., Woiwode, W., Bernath, P. F., Boone, C., Dutton, G. S., Elkins, J. W., Engel, A., Gille, J. C., Kolonjari, F., Sugita, T., Toon, G. C., and Walker, K. A.: MIPAS IMK/IAA CFC-11 (CCl<sub>3</sub>F) and CFC-12 (CCl<sub>2</sub>F<sub>2</sub>) measurements: accuracy, precision and long-term stability, Atmos. Meas. Tech., 9, 3355–3389, <a href="https://doi.org/10.5194/amt-9-3355-2016" target="_blank">https://doi.org/10.5194/amt-9-3355-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Garcia et al.(2007)</label><mixed-citation>
Garcia, R. R., Marsh,  D. R., Kinnison, D. E., Boville, B. A., and Sassi F.: Simulation of secular trends in the middle atmosphere, 1950–2003, J. Geophys. Res., 112, D09301, <a href="https://doi.org/10.1029/2006JD007485" target="_blank">https://doi.org/10.1029/2006JD007485</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Gardiner et al.(2008)</label><mixed-citation>
Gardiner, T., Forbes, A., de Mazière, M., Vigouroux, C., Mahieu, E., Demoulin, P., Velazco, V., Notholt, J., Blumenstock, T., Hase, F., Kramer, I., Sussmann, R., Stremme, W., Mellqvist, J., Strandberg, A., Ellingsen, K., and Gauss, M.: Trend analysis of greenhouse gases over Europe measured by a network of ground-based remote FTIR instruments, Atmos. Chem. Phys., 8, 6719–6727, <a href="https://doi.org/10.5194/acp-8-6719-2008" target="_blank">https://doi.org/10.5194/acp-8-6719-2008</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Goldman et al.(1981)</label><mixed-citation>
Goldman, A., Murcray, F. J., Blatherwick, R. D., Bonomo, F. S., Murcray, F. H., and Murcray, D. G.: Spectroscopic identification of CHClF2 (F-22) in the lower stratosphere, Geophys. Res. Lett., 8, 1012–1014, 1981.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Hase et al.(2004)</label><mixed-citation>
Hase, F., Hannigan, J. W., Coffey, M. T., Goldman, A., Höpfner, M.,
Jones, N. B., and Rinsland, C. P., Wood, S. W.: Intercomparison of retrieval codes used for the analysis of high-resolution, ground-based FTIR measurements, J. Quant. Spectrosc. Ra., 87, 25–52, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Hoffmann and Riese(2004)</label><mixed-citation>
Hoffmann, L. and Riese, M.: Quantitative transport studies based on trace gas
assimilation, Adv. Space Res., 33, 1068–1072,
doi:10.1016/S0273-1177(03)00592-1, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Hoffmann et al.(2008)</label><mixed-citation>
Hoffmann, L., Kaufmann, M., Spang, R., Müller, R., Remedios, J. J., Moore, D. P., Volk, C. M., von Clarmann, T., and Riese, M.: Envisat MIPAS measurements of CFC-11: retrieval, validation, and climatology, Atmos. Chem. Phys., 8, 3671–3688, <a href="https://doi.org/10.5194/acp-8-3671-2008" target="_blank">https://doi.org/10.5194/acp-8-3671-2008</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Hudgins et al.(1993)</label><mixed-citation>
Hudgins, D. M., Sandford, S. A., Allamandola, L. J., and Tielens, A. G. G. M.: Mid- and Far-Infrared Spectroscopy of Ices: Optical Constants and
Integrated Absorbances,  Astrophys. J. Suppl. S., 86, 713–870,
<a href="https://doi.org/10.1086/191796" target="_blank">https://doi.org/10.1086/191796</a>, 1993.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>IRWG-NDACC(2021)</label><mixed-citation>
IRWG-NDACC: WACCM V.6 profiles dataset for IRWG sites, NDACC Infrared Working Group, available at: <a href="ftp://nitrogen.acom.ucar.edu/user/jamesw/IRWG/2013/WACCM/V6" target="_blank"/>, last access: 19 June 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Kellmann et al.(2012)</label><mixed-citation>
Kellmann, S., von Clarmann, T., Stiller, G. P., Eckert, E., Glatthor, N., Höpfner, M., Kiefer, M., Orphal, J., Funke, B., Grabowski, U., Linden, A., Dutton, G. S., and Elkins, J. W.: Global CFC-11 (CCl<sub>3</sub>F) and CFC-12 (CCl<sub>2</sub>F<sub>2</sub>) measurements with the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS): retrieval, climatologies and trends, Atmos. Chem. Phys., 12, 11857–11875, <a href="https://doi.org/10.5194/acp-12-11857-2012" target="_blank">https://doi.org/10.5194/acp-12-11857-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Khosrawi et al.(2004)</label><mixed-citation>
Khosrawi, F., Müller, R., Irie, H., Engel, A., Toon, G., Sen, B., Aoki, S.,
Nakazawa, T., Traub, W., and Jucks, K. J.: Validation of CFC-12 measurements
from the Improved Limb Atmospheric Spectrometer (ILAS) with the version 6.0
retrieval algorithm, J. Geophys. Res., 109, D06311,
<a href="https://doi.org/10.1029/2003JD004325" target="_blank">https://doi.org/10.1029/2003JD004325</a>, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Lynch(2006)</label><mixed-citation>
Lynch, D. K.: The Infrared Spectral Signature of Water Ice in the Vacuum
Cryogenic AI&amp;T Environment, Aerospace Report No. TR-2006(8570)-1, The Aerospace Corporation Laboratory Operations, El Segundo, Los Angeles Air Force Base, CA, USA, 19 pp., 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Mahieu et al.(2013)</label><mixed-citation>
Mahieu, E., O’Doherty, S., Reimann, S., Vollmer, M., Bader, W., Bovy, B.,
Lejeune, B., Demoulin, P., Roland G., and Servais, C.: First retrievals of
HCFC-142b from ground-based high-resolution FTIR solar observations:
application to high-altitude Jungfraujoch spectra, EGU General Assembly, Vienna, Austria, 7–12 April 2013, EGU2013-1185-1, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Mahieu et al.(2008)</label><mixed-citation>
Mahieu, E., Duchatelet, P., Demoulin, P., Walker, K. A., Dupuy, E., Froidevaux, L., Randall, C., Catoire, V., Strong, K., Boone, C. D., Bernath, P. F., Blavier, J.-F., Blumenstock, T., Coffey, M., De Mazière, M., Griffith, D., Hannigan, J., Hase, F., Jones, N., Jucks, K. W., Kagawa, A., Kasai, Y., Mebarki, Y., Mikuteit, S., Nassar, R., Notholt, J., Rinsland, C. P., Robert, C., Schrems, O., Senten, C., Smale, D., Taylor, J., Tétard, C., Toon, G. C., Warneke, T., Wood, S. W., Zander, R., and Servais, C.: Validation of ACE-FTS v2.2 measurements of HCl, HF, CCl<sub>3</sub>F and CCl<sub>2</sub>F<sub>2</sub> using space-, balloon- and ground-based instrument observations, Atmos. Chem. Phys., 8, 6199–6221, <a href="https://doi.org/10.5194/acp-8-6199-2008" target="_blank">https://doi.org/10.5194/acp-8-6199-2008</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Mahieu et al.(2017)</label><mixed-citation>
Mahieu, E., Lejeune, B., Bovy, B., Servais, C., Toon, G. C., Bernath, P. F.,
Boone, C. D., Walker, K. A., Reimann, S., and Vollmer, M. K.: Retrieval of
HCFC-142b (CH<sub>3</sub>CClF<sub>2</sub>) from ground-based high–resolution infrared solar spectra: Atmospheric increase since 1989 and comparison with surface and satellite measurements, J. Quant. Spectrosc. Ra., 186, 96–105, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Mahieu et al.(2010)</label><mixed-citation>
Mahieu, E., Rinsland, C. P., Gardiner, T., Zander, R., Demoulin, P., Chipperfield, M. P., Ruhnke, R., Chiou, L. S., De Mazière, M., and the GIRPAS Team: Recent trends of inorganic chlorine and halogenated source gases abovethe Jungfraujoch and Kitt Peak stations derived from high-resolution FTIR solar observations, EGU General Assembly, Vienna, Austria, 2–7 May 2010, EGU2010-2420-3, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>MHD CFC-11 data(2021)</label><mixed-citation>
MHD CFC-11 data: Mace Head site measurement data of CFC-11, National Oceanicand Atmospheric Administration (NOAA)/Global Monitoring Division
(GMD) in Boulder CO, available at: <a href="ftp://ftp.cmdl.noaa.gov/hats/cfcs/cfc11/flasks/GCMS/CFC11b_GCMS_flask.txt" target="_blank"/>, last access: 28 June 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>MHD CFC-12 data(2021)</label><mixed-citation>
MHD CFC-12 data: Mace Head site measurement data of CFC-12, National Oceanicand Atmospheric Administration (NOAA)/Global Monitoring Division
(GMD) in Boulder CO, available at: <a href="ftp://ftp.cmdl.noaa.gov/hats/cfcs/cfc12/flasks/GCMS/CFC12_GCMS_flask.txt" target="_blank"/>, last access: 28 June 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>MHD HCFC-22 data(2021)</label><mixed-citation>
MHD HCFC-22 data: Mace Head site measurement data of HCFC-22, National Oceanicand Atmospheric Administration (NOAA)/Global Monitoring Division
(GMD) in Boulder CO, available at: <a href="ftp://ftp.cmdl.noaa.gov/hats/hcfcs/hcfc22/flasks/HCFC22_GCMS_flask.txt" target="_blank"/>, last access: 28 June 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Mlawer et al.(2012)</label><mixed-citation>
Mlawer, E. J., Payne, V. H., Moncet, J. L., Delamere, J. S., Alvarado, M. J.,
Tobin, D. D.: Development and recent evaluation of the MT_CKD model of
continuum absorption, Philos. T. R. Soc. A, 370, 2520–2556,
<a href="https://doi.org/10.1098/rsta.2011.0295" target="_blank">https://doi.org/10.1098/rsta.2011.0295</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Molina and Rowland(1974)</label><mixed-citation>
Molina, M. and Rowland, F.: Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone, Nature, 249, 810–812,
<a href="https://doi.org/10.1038/249810a0" target="_blank">https://doi.org/10.1038/249810a0</a>, 1974.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Montzka et al.(1993)</label><mixed-citation>
Montzka, S. A., Myers, R. C., Butler, J. H., Elkins, J. W., and Cummings, S. O.: Global tropospheric distribution and calibration scale of HCFC-22, Geophys. Res. Lett., 20, 703–706, <a href="https://doi.org/10.1029/93GL00753" target="_blank">https://doi.org/10.1029/93GL00753</a>, 1993.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Montzka et al.(2018)</label><mixed-citation>
Montzka, S. A., Dutton, G. S., Yu, P., Ray, E., Portmann, R. W., Daniel J. S., Kuijpers, L., Hall, B. D., Mondeel, D., Siso, C., Nance, J. D., Rigby, M., Manning, A. J., Hu, L.,  Moore, F., Miller, B. R., and Elkins, J. W.:  An unexpected and persistent increase in global emissions of ozone–depleting CFC-11, Nature, 557, 413–417, <a href="https://doi.org/10.1038/s41586-018-0106-2" target="_blank">https://doi.org/10.1038/s41586-018-0106-2</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>NDACC(2021)</label><mixed-citation>
Network for the Detection of Atmospheric Composition Change (NDACC): NDACC public data archive, available at: <a href="https://www-air.larc.nasa.gov/missions/ndacc/data.html" target="_blank"/>, last access: 29 July 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Notholt(1994)</label><mixed-citation>
Notholt, J.: FTIR measurements of HF, N<sub>2</sub>O and CFCs during the Arctic polar
night with the Moon as light source, subsidence during winter 1992/93,
Geophys. Res. Lett., 21, 2385–2388, <a href="https://doi.org/10.1029/94GL02351" target="_blank">https://doi.org/10.1029/94GL02351</a>, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Park et al.(2013)</label><mixed-citation>
Park, M., Randel, W. J., Kinnison, D. E., Emmons, L. K., Bernath, P. F.,
Walker, K. A., Boone, C. D., and Livesey, M. J.: Hydrocarbons in the upper
troposphere and lower stratosphere observed from ACE-FTS and comparisons
with WACCM, J. Geophys. Res.-Atmos., 118, 1964–1980,
<a href="https://doi.org/10.1029/2012JD018327" target="_blank">https://doi.org/10.1029/2012JD018327</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Phillips(1962)</label><mixed-citation>
Phillips, D.: A technique for the numerical solution of certain integral
equations of the first kind, J. ACM, 9, 84–97, <a href="https://doi.org/10.1145/321105.321114" target="_blank">https://doi.org/10.1145/321105.321114</a>, 1962.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>Polyakov et al.(2020a)</label><mixed-citation>
Polyakov, A., Virolainen, Y., Poberovskiy, A., Makarova, M., and Timofeyev, Y.: Atmospheric HCFC-22 total columns near St. Petersburg: stabilization with
start of a decrease, Int. J. Rem. Sens., 41, 4365–4371, <a href="https://doi.org/10.1080/01431161.2020.1717668" target="_blank">https://doi.org/10.1080/01431161.2020.1717668</a>, 2020a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>Polyakov et al.(2018)</label><mixed-citation>
Polyakov, A. V., Timofeyev, Y. M., Virolainen, Y. A., Makarova, M. V.,
Poberovskii, A. V., and Imhasin, H. K.: Ground-Based Measurements of the
Total Column of Freons in the Atmosphere near St. Petersburg (2009–2017),
Izv. Atmos. Ocean. Phy., 54, 487–494, <a href="https://doi.org/10.1134/S0001433818050109" target="_blank">https://doi.org/10.1134/S0001433818050109</a>,
2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>Polyakov et al.(2019a)</label><mixed-citation>
Polyakov, A. V., Virolainen, Y. A., and Makarova, M. V.: Technique for Inverting Transmission Spectra to Measure Freon Concentration, J. Appl. Spectrosc., 85, 1085–1093, <a href="https://doi.org/10.1007/s10812-019-00763-y" target="_blank">https://doi.org/10.1007/s10812-019-00763-y</a>, 2019a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>Polyakov et al.(2019b)</label><mixed-citation>
Polyakov, A. V., Virolainen, Y. A., and Makarova M. V.: Method For Inversion Of The Transparency Spectra For Evaluating The Content of CCl<sub>2</sub>F<sub>2</sub> In The
Atmosphere, J. Appl. Spectrosc., 86, 449–456, <a href="https://doi.org/10.1007/s10812-019-00840-2" target="_blank">https://doi.org/10.1007/s10812-019-00840-2</a>, 2019b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>Polyakov et al.(2020b)</label><mixed-citation>
Polyakov, A. V., Poberovsky, A. V., Virolainen, Y. A., and Makarova M. V.:
Transparency Spectra Inversion Technique for Evaluating the Atmospheric
Content of CCl<sub>3</sub>F freon, J. Appl. Spectrosc., 87, 92–98, <a href="https://doi.org/10.1007/s10812-020-00968-6" target="_blank">https://doi.org/10.1007/s10812-020-00968-6</a>, 2020b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>Prignon et al.(2019)</label><mixed-citation>
Prignon, M., Chabrillat, S., Minganti, D., O'Doherty, S., Servais, C., Stiller, G., Toon, G. C., Vollmer, M. K., and Mahieu, E.: Improved FTIR retrieval strategy for HCFC-22 (CHClF<sub>2</sub>), comparisons with in situ and satellite datasets with the support of models, and determination of its long-term trend above Jungfraujoch, Atmos. Chem. Phys., 19, 12309–12324, <a href="https://doi.org/10.5194/acp-19-12309-2019" target="_blank">https://doi.org/10.5194/acp-19-12309-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>Rinsland et al.(2005)</label><mixed-citation>
Rinsland, C. P., Chiou, L. S., Goldman, A., and Wood, S. W.:
Long-term trend in CHF2Cl (HCFC-22) from high spectral resolution infrared
solar absorption measurements and comparisons with in situ measurements,
J. Quant. Spectrosc. Ra., 90, 367–375, 2005
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>Rinsland et al.(2010)</label><mixed-citation>
Rinsland, C. P., Chiou, L., Goldman, A., and Hannigan, J. W.: Multi-decade
measurements of the long-term trends of atmospheric species by
high-spectral-resolution infrared solar absorption spectroscopy,
J. Quant. Spectrosc. Ra., 111, 376–383, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>Rodgers(2000)</label><mixed-citation>
Rodgers, C. D.: Inverse Methods for Atmospheric Sounding: Theory and
Practice, in: Series on Atmospheric, Oceanic and Planetary Physics: Volume 2,
World Scientific Publishing, Singapore, 238 pp., <a href="https://doi.org/10.1142/3171" target="_blank">https://doi.org/10.1142/3171</a>, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>Rodgers and Connor(2003)</label><mixed-citation>
Rodgers, C. D. and Connor, B. J.: Intercomparison of remote sounding
instruments, J. Geophys. Res., 108, 4116, <a href="https://doi.org/10.1029/2002JD002299" target="_blank">https://doi.org/10.1029/2002JD002299</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>Santer et al.(2000)</label><mixed-citation>
Santer, B. D., Wigley, T. M. L., Boyle, J. S., Gaffen, D. J., Hnilo, J. J., Nychka, D., Parker, D. E., and Taylor, K. E.: Statistical significance of trends and trend differences in layeraverage atmospheric temperature time series, J. Geophys. Res., 105, 7337–7356, <a href="https://doi.org/10.1029/1999JD901105" target="_blank">https://doi.org/10.1029/1999JD901105</a>, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>Senten et al.(2012)</label><mixed-citation>
Senten, C., De Mazière, M., Vanhaelewyn, G., and Vigouroux, C.: Information operator approach applied to the retrieval of the vertical distribution of atmospheric constituents from ground-based high-resolution FTIR measurements, Atmos. Meas. Tech., 5, 161–180, <a href="https://doi.org/10.5194/amt-5-161-2012" target="_blank">https://doi.org/10.5194/amt-5-161-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>Solomon et al.(2014)</label><mixed-citation>
Solomon, S., Haskins, J., Ivy, D., and Min, F.: Fundamental differences
between Arctic and Antarctic ozone depletion, P. Natl. Acad. Sci. USA, 111,
6220–6225, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>Sussmann et al.(2011)</label><mixed-citation>
Sussmann, R., Forster, F., Rettinger, M., and Jones, N.: Strategy for high-accuracy-and-precision retrieval of atmospheric methane from the mid-infrared FTIR network, Atmos. Meas. Tech., 4, 1943–1964, <a href="https://doi.org/10.5194/amt-4-1943-2011" target="_blank">https://doi.org/10.5194/amt-4-1943-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>Tikhonov(1963)</label><mixed-citation>
Tikhonov, A., On the solution of incorrectly stated problems and a method
of regularization, Dokl. Akad. Nauk SSSR, 151, 501–504, 1963.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>Timofeyev et al.(2016)</label><mixed-citation>
Timofeyev Yu., Virolainen, Ya., Makarova, M., Poberovsky, A., Polyakov, A.,
Ionov, D., Osipov, S., and Imhasin, H.: Ground-based spectroscopic measurements of atmospheric gas composition near Saint Petersburg (Russia), J. Mol. Spectrosc., 323, 2–14, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>Timofeev et al.(2020)</label><mixed-citation>
Timofeev, Yu. M., Polyakov, A. V., Virolainen, Ya. A., Makarova, M. V., Ionov, D. V., Poberovsky, A. V., and Imhasin, H. H.: Estimates of Trends of Climatically Important Atmospheric Gases Near St. Petersburg, Izv. Atmos. Ocean. Phy., 56, 79–84, 2020b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>Virolainen et al.(2017)</label><mixed-citation>
Virolainen, Y. A., Timofeyev, Y. M., Kostsov, V. S., Ionov, D. V., Kalinnikov, V. V., Makarova, M. V., Poberovsky, A. V., Zaitsev, N. A., Imhasin, H. H., Polyakov, A. V., Schneider, M., Hase, F., Barthlott, S., and Blumenstock, T.: Quality assessment of integrated water vapour measurements at the St. Petersburg site, Russia: FTIR vs. MW and GPS techniques, Atmos. Meas. Tech., 10, 4521–4536, <a href="https://doi.org/10.5194/amt-10-4521-2017" target="_blank">https://doi.org/10.5194/amt-10-4521-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>WMO(1985)</label><mixed-citation>
WMO (World Meteorological Organization): Atmospheric ozone 1985: assessment
of our understanding of the processes controlling its present distribution
and change, Global Ozone Research and Monitoring Project – Report
No. 16, WMO, Geneva, Switzerland, 588 pp., 1985.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>WMO(2018)</label><mixed-citation>
WMO (World Meteorological Organization): Scientific Assessment of Ozone
Depletion: 2018, Global Ozone Research and Monitoring Project – Report
No. 58, WMO, Geneva, Switzerland, 588 pp., 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>Yagovkina et al.(2011)</label><mixed-citation>
Yagovkina, I. S., Polyakov, A. V., Poberovskii, A. V., and Timofeyev, Yu. M.: Spectroscopic measurements of total CFC-11 freon in the atmosphere near St. Petersburg, Izv. Atmos. Ocean. Phy., 47, 186–189, <a href="https://doi.org/10.1134/S0001433811020125" target="_blank">https://doi.org/10.1134/S0001433811020125</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>Zander et al.(2005)</label><mixed-citation>
Zander, R., Mahieu, E., Demoulin, P., Duchatelet, P., Servais, C., Roland, G., Delbouille, L., De Mazière, M., and Rinsland, C. P.: Evolution of a dozen
non-CO<sub>2</sub> greenhouse gases above Central Europe since the mid-1980s, Environ. Sci., 2, 295–303, <a href="https://doi.org/10.1080/15693430500397152" target="_blank">https://doi.org/10.1080/15693430500397152</a>, 2005.

</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>Zhou et al.(2016)</label><mixed-citation>
Zhou, M., Vigouroux, C., Langerock, B., Wang, P., Dutton, G., Hermans, C., Kumps, N., Metzger, J.-M., Toon, G., and De Mazière, M.: CFC-11, CFC-12 and HCFC-22 ground-based remote sensing FTIR measurements at Réunion Island and comparisons with MIPAS/ENVISAT data, Atmos. Meas. Tech., 9, 5621–5636, <a href="https://doi.org/10.5194/amt-9-5621-2016" target="_blank">https://doi.org/10.5194/amt-9-5621-2016</a>, 2016.
</mixed-citation></ref-html>--></article>
