<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article"><?xmltex \makeatother\@nolinetrue\makeatletter?>
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-14-6835-2021</article-id><title-group><article-title>Quantification of isomer-resolved iodide chemical ionization<?xmltex \hack{\break}?> mass spectrometry sensitivity and uncertainty using a voltage-scanning approach</article-title><alt-title>Quantification of iodide CIMS sensitivity and voltage-scanning uncertainty</alt-title>
      </title-group><?xmltex \runningtitle{Quantification of iodide CIMS sensitivity and voltage-scanning uncertainty}?><?xmltex \runningauthor{C.~Bi et~al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Bi</surname><given-names>Chenyang</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-0131-0310</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Krechmer</surname><given-names>Jordan E.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3642-0659</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Frazier</surname><given-names>Graham O.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-0544-4984</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Xu</surname><given-names>Wen</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-2084-2630</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Lambe</surname><given-names>Andrew T.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Claflin</surname><given-names>Megan S.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-0878-8712</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Lerner</surname><given-names>Brian M.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-8721-8165</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Jayne</surname><given-names>John T.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Worsnop</surname><given-names>Douglas R.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Canagaratna</surname><given-names>Manjula R.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Isaacman-VanWertz</surname><given-names>Gabriel</given-names></name>
          <email>ivw@vt.edu</email>
        <ext-link>https://orcid.org/0000-0002-3717-4798</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>Department of Civil and Environmental Engineering, Virginia Tech,
Blacksburg, Virginia 24060, USA</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Aerodyne Research Inc, Billerica, Massachusetts 01821, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Gabriel Isaacman-VanWertz (ivw@vt.edu)</corresp></author-notes><pub-date><day>25</day><month>October</month><year>2021</year></pub-date>
      
      <volume>14</volume>
      <issue>10</issue>
      <fpage>6835</fpage><lpage>6850</lpage>
      <history>
        <date date-type="received"><day>4</day><month>June</month><year>2021</year></date>
           <date date-type="accepted"><day>25</day><month>September</month><year>2021</year></date>
           <date date-type="rev-recd"><day>10</day><month>September</month><year>2021</year></date>
           <date date-type="rev-request"><day>7</day><month>June</month><year>2021</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2021 Chenyang Bi et al.</copyright-statement>
        <copyright-year>2021</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021.html">This article is available from https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e181">Chemical ionization mass spectrometry (CIMS) using iodide as a reagent ion has been widely used to classify organic compounds in the atmosphere by their
elemental formula. Unfortunately, calibration of these instruments is
challenging due to a lack of commercially available standards for many
compounds, which has led to the development of methods for estimating CIMS
sensitivity. By coupling a thermal desorption aerosol gas chromatograph (TAG) simultaneously to a flame ionization detector (FID) and an iodide CIMS, we use
the individual particle-phase analytes, quantified by the FID, to examine the
sensitivity of the CIMS and its variability between isomers of the same
elemental formula. Iodide CIMS sensitivities of isomers within a formula are
found to generally vary by 1 order of magnitude with a maximum deviation of 2 orders of magnitude. Furthermore, we compare directly measured sensitivity
to a method of estimating sensitivity based on declustering voltage (i.e.,
“voltage scanning”). This approach is found to carry high uncertainties for
individual analytes (0.5 to 1 order of magnitude) but represents a central tendency that can be used to estimate the sum of analytes with reasonable
error (<inline-formula><mml:math id="M1" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">30</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M2" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> differences between predicted and measured
moles). Finally, gas chromatography (GC) retention time, which is associated with vapor pressure and chemical functionality of an analyte, is found to qualitatively correlate
with iodide CIMS sensitivity, but the relationship is not close enough to be
quantitatively useful and could be explored further in the future as a
potential calibration approach.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e211">Air pollution is ranked as a major risk factor for global illness and death
(Stanaway et al., 2018). Exposure to ambient fine particulate matter
(<inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) is associated with severe health outcomes (Burnett et al.,
2014; Pope and Dockery, 2006). A substantial fraction of <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn mathvariant="normal">2.5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is
secondary organic aerosol (SOA) that is generated through atmospheric
oxidation of volatile organic compounds (VOCs) (Hallquist et al., 2009; Kroll
and Seinfeld, 2008; Shrivastava et al., 2017).  Characterizing the molecular
composition of organics in SOA and precursor gases is crucial for
understanding the chemical fate, removal, and ultimately the impact on human
and environmental health. However, the complexity of atmospheric mixtures
represents a significant analytical challenge (Goldstein and Galbally, 2007;
Jimenez et al., 2009; Kroll and Seinfeld, 2008).</p>
      <p id="d1e236">High-resolution time-of-flight chemical ionization mass spectrometry
(HR-ToF-CIMS) has been widely used to directly sample and characterize gas-
and particle-phase organics in ambient and laboratory-generated atmospheres.
Chemical ionization offers a relatively “soft” technique in which analytes
form ions that do not significantly fragment within the mass spectrometer.
Since the original ions (“parent ions”) are preserved for detection by a high-resolution mass spectrometer, their elemental formulas can be identified
from the accurate mass of detected ions. These instruments consequently
classify the diverse atmospheric components by their formulas, though they
cannot provide much information<?pagebreak page6836?> regarding molecular structure. A variety of
reagent ions are used in atmospheric applications of CIMS, each of which
provides selectivity for analytes with a different range of chemical
properties, with the most widely used including iodide for the detection of a wide range of polar organic compounds (Lee et al., 2014; Slusher et al.,
2004), <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CF</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> for oxygenated organics including hydroperoxides
(Crounse et al., 2006), acetate for organic acids (Bertram et al., 2011;
Brophy and Farmer, 2016), nitrate for highly oxygenated organics (Jokinen et
al., 2012; Krechmer et al., 2015), hydronium for VOCs (Yuan et al., 2016),
benzene cation for select biogenic VOCs (Kim et al., 2016), and <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">NO</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>
for branched alkanes, alkyl-substituted aromatics, and other VOCs (Koss
et al., 2016). Iodide is frequently used as a reagent ion in CIMS due to its
simple ionization chemistry (Aljawhary et al., 2013; Lee et al., 2014; Pagonis
et al., 2019; Riva et al., 2019; Zhang et al., 2018). Iodide forms an adduct
with the neutral analyte molecule, and the adduct can be used for compound identification and quantification. The iodide–molecule adduct can be easily resolved from any non-adduct ions due to the high negative mass defect of
iodine. Therefore, an iodide CIMS enables the online measurement of oxygenated
organic compounds with confident classification by an elemental formula and high time resolution.</p>
      <p id="d1e266">The major limitation of an iodide CIMS is its large range of sensitivities to
different molecules, which can range across several orders of magnitude (Iyer
et al., 2016) due to variations in binding enthalpies between neutrals and the
iodide anion. Quantification of an analyte consequently requires calibration
using commercially available or synthesized chemical standards of the target analytes. However, doing so for many analytes is costly and labor-intensive,
and many of the oxidation products present in ambient atmospheres cannot be
efficiently synthesized or isolated as pure compounds (Brophy,
2016). Furthermore, an analyte of interest may exist in the atmosphere
alongside other isomers of the same elemental formula, which are not resolved
by a mass spectrometer alone, confounding efforts to calibrate using
individual analytes. These difficulties have led to the development of
empirical approaches to tackle the calibration of atmospheric constituents. In
theory, iodide CIMS has a maximum sensitivity dictated by the collision rate
of reagent ions (<inline-formula><mml:math id="M7" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) with analyte ions, assuming that any collision forms
an adduct. This maximum sensitivity can be calculated based on the interaction
time of analyte molecules with reagent ions (Huey et al., 1995; Kercher
et al., 2009; Lee et al., 2014). Experimentally, an analyte to which the
iodide CIMS is known to be maximally sensitive (typically <inline-formula><mml:math id="M8" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)
can be used as a calibrant to determine the observed maximum sensitivity of
the instrument, which typically agrees well (Lopez-Hilfiker et al., 2016) or
at least within a factor of 4 (Isaacman-VanWertz et al., 2018) with the theoretical observed maximum sensitivity. However, these methods estimate only
maximum possible sensitivity, while many analytes may not efficiently form
iodide adducts, or the formed adducts may decompose to generate fewer
detectable ions per molecule (Lopez-Hilfiker et al., 2016).</p>
      <p id="d1e296">Quantification based on maximum sensitivity provides only a lower limit on the
concentration of observed analytes. To refine this quantification method, Iyer
et al. (2016) demonstrated through computational work that the binding energy
of an analyte with the reagent ion is log-linearly correlated with observed sensitivity. The binding energy can, in turn, be estimated by varying the
voltage differentials in the mass spectrometer focusing optics to induce
de-clustering (specifically, the voltage differential between the skimmer of
the first quadrupole and the entrance to the second quadrupole ion guide)
(Lopez-Hilfiker et al., 2016).  Lopez-Hilfiker et al. (2016) showed that
“de-clustering scans” or “voltage scans” could empirically provide
approximate sensitivity of an iodide CIMS, which has since been extended to
estimate the sensitivity of other reagent ion chemistries (i.e., acetate and
<inline-formula><mml:math id="M9" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>) by modulating various operating conditions to probe product-ion
formation and stability (Brophy and Farmer, 2016; Zaytsev et al.,
2019). However, the quantitative relationships between sensitivity and
variations in operating conditions are built on a small number of available
chemical standards. It is not well known whether these relationships hold for
the large number of short-lived and complex compounds generated in the
atmospheric oxidative processes or how best to validate them for short-lived atmospheric components.</p>
      <p id="d1e313">A further challenge for quantification of CIMS data is that isomers cannot be
differentiated because analytes are measured only by their elemental
formulas. These formulas likely represent multiple molecules, as isomers are
found to be prevalent in the atmosphere and may vary by orders of magnitude in
their CIMS sensitivity (Lee et al., 2014). Based on samples collected from a
wide range of instruments and environments, Bi et al. (2021b) demonstrated
that laboratory-generated samples of simulated atmospheric oxidation contain
many molecules of the same elemental formula – typically 2 to 4 but up to nearly 20. Previous work has also found very high sample-to-sample and
day-to-day variability in molecular-level particle composition (Ditto et al.,
2018), suggesting a CIMS-detected elemental formula may represent a dynamic
and variable set of isomers. These isomers, while having the same elemental formula, may have significantly different functional groups and detailed
chemical structures which consequently determine their physical and chemical
properties (Atkinson and Arey, 2003; Goldstein and Galbally, 2007). Vapor
pressure, polarity, reactivity, and compound toxicity are all impacted by the
functional groups present in a molecule (Arangio et al., 2016) and in some cases by its physical conformation (Atkinson, 2000; Lim and Ziemann, 2009). An
accurate analysis of the deconvolution of isomers in complex samples is
therefore necessary to determine the molecular-level composition of the
atmosphere, study the formation, transport, and fate of airborne organics, and
better understand their impacts on global climate<?pagebreak page6837?> and human health. To better apply CIMS instrumentation to these questions and understand the impacts of
changing isomer composition on calibration, it is important to investigate the variability in CIMS sensitivity between isomers.</p>
      <p id="d1e316">Isomer-resolved analysis is typically achieved using chromatography
techniques. In this work, we focus on gas chromatography (GC), which has been
demonstrated to be an effective way for the online analysis of low-polarity
gas-phase components (Goldan et al., 2004; Goldstein et al., 1995; Helmig
et al., 2007; Millet, 2005; Prinn et al., 2000; Vasquez et al., 2018). More
recently, GC has been demonstrated as a field-deployable technique for the
analysis of lower-volatility organics using the thermal desorption aerosol gas chromatograph (TAG), particularly with recent work expanding its application
to oxygenates that might be detectable by iodide CIMS (Bi et al., 2021b;
Isaacman-VanWertz et al., 2016; Isaacman et al., 2014; Thompson et al., 2017;
Williams et al., 2006; Zhao et al., 2013). Typically, detection of analytes
eluting from a GC is achieved by either a flame ionization detector (FID), which has near-universal response but provides no chemical information about an
analyte (Grob and Barry, 2004; Kolb et al., 1977), or an electron ionization
mass spectrometer (EI-MS). The latter provides identification of compounds
with mass spectra available in existing libraries, but structural or molecular
information of compounds not in those libraries requires careful
interpretation of mass spectra. Unfortunately, compounds not in existing
libraries account for a substantial fraction of compounds in SOA. This
shortcoming has, in part, led to recent efforts to couple GC with CIMS for
detection to provide the classification of unknown analytes by their elemental
formulas (Bi et al., 2021b; Koss et al., 2016; Vasquez et al., 2018).</p>
      <p id="d1e319">We recently demonstrated a coupled TAG-CIMS/FID, in which particle-phase
organics are collected and analyzed by a TAG, with analyte detection
simultaneously achieved by an FID and an iodide CIMS (Bi et al., 2021b). This
approach allows quantification of individual analytes in particle-phase
organics by the FID, with simultaneous classification by their elemental formula through CIMS. In this work, we focus on quantifying the sensitivity of an
iodide CIMS to different isomers of the same elemental formula by comparing
signals of a CIMS with quantification of each isomer mass based on FID
response.  Specific objectives are to (1) compare the iodide CIMS sensitivity
of isomers of a given elemental formula, (2) examine the efficacy of voltage scans to predict the sensitivity of a given analyte or formula, and (3)
determine the extent to which the additional dimension of GC retention time
can inform estimates of iodide CIMS sensitivity.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Instrumentation and methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Instrument operation</title>
      <p id="d1e337"><italic>TAG configuration</italic>. The TAG-CIMS/FID couples a GC instrument, the TAG,
with two detectors, a HR-ToF-CIMS (Aerodyne Research Inc.) using iodide as the
reagent ion and an FID (Agilent Technologies). The TAG-CIMS/FID enables
online, isomer-resolved analysis of particle-phase oxygenated organics through
sample collection followed by separation of isomers by GC. Quantification
relies on an FID, calibrated by automated injection of a small number of
calibrants and internal standards. Details of the instrument, sampling
procedure, and chemical analysis method are described by Bi et al. (2021b).
In brief, the TAG collects aerosol samples by impaction into a passivated
steel cell at a sample flow rate of 9 <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula>, typically for
5–15 <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula> in this work with an equivalent volume of 45–135 <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi></mml:mrow></mml:math></inline-formula>
air. Liquid chemical standards are injected into the cell through the
automated liquid injection system of the TAG (Isaacman et al., 2011).  Samples
collected by the cell are then transferred to the GC column through programmed
thermal desorption. A polar GC column (MXT-WAX, <inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:mn mathvariant="normal">17</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">0.25</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow><mml:mo>×</mml:mo><mml:mn mathvariant="normal">0.25</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula>, Restek) wrapped on a
temperature-controlled metal hub is used for the separation of oxygenated
organic compounds (50 to 250 <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> at a rate of
10 <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> and then held for 25 <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula>). Though analysis of oxygenates
by GC (in general) or TAG (specifically) typically relies on derivatization to
convert difficult-to-elute polar functional groups (e.g., hydroperoxides) into
easier-to-elute groups (Isaacman et al., 2014), this approach is not employed
here to minimize chemical alterations to the functionality of the analytes
reaching the detectors. The GC column effluent is split to the two detectors,
0.7 <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">sccm</mml:mi></mml:mrow></mml:math></inline-formula> to CIMS and 0.3 <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">sccm</mml:mi></mml:mrow></mml:math></inline-formula> to FID, using a heated and
passivated tee (SilcoNert 2000, SilcoTek Corp.) with heated fused-silica
transfer lines for simultaneous measurements by CIMS and FID.  The detailed
validation of the split ratio is described by Bi et al. (2021b).</p>
      <?pagebreak page6838?><p id="d1e454"><italic>CIMS configuration.</italic> The configuration of the HR-ToF-CIMS using iodide
as the reagent ion is described in detail by Bi et al. (2021b) and is operated
similarly to typical direct air sampling by CIMS (e.g., Isaacman-VanWertz et al., 2018).  Briefly, iodide ions are generated by passing a 2 <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula>
flow of humidified ultrahigh purity (UHP) <inline-formula><mml:math id="M20" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> over a permeation tube
filled with methyl iodide and then through a radioactive source (Po-210,
10 <inline-formula><mml:math id="M21" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mCi</mml:mi></mml:mrow></mml:math></inline-formula>, NRD) into the ion-molecule reactor (IMR), which is maintained
at 100 <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mbar</mml:mi></mml:mrow></mml:math></inline-formula>. Voltages for the ion transfer optics are
instrument-dependent due to slight differences in geometry, so we recommend
that other users tune the voltages to maximize sensitivity for a weak iodide
adduct while minimizing the voltage gradient, which is the tuning approach
taken in this study. Major differences between the current instrumental setup
and a direct-air-sampling CIMS are highlighted here. The inlet of the CIMS is
modified by adding a 225 <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> metal cartridge with a
bore-through hole to allow the insertion of the transfer line, a fused-silica
guard column, into the IMR.  Helium flow eluting from the GC
(0.7 <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">sccm</mml:mi></mml:mrow></mml:math></inline-formula>) mixes with 2 <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> of reagent ion flow in the IMR; the <inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">3000</mml:mn><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> dilution of this effluent is roughly balanced by the
preconcentration of the sample in the impactor cell such that the detected concentrations are similar to those expected under typical direct-air-sampling
conditions. The CIMS is operated in two modes, regular mode and voltage-scanning mode, which differ in their data acquisition rates and voltage settings. In regular mode, to obtain a smooth chromatographic peak, raw
negative-ion spectra are acquired at a rate of 4 <inline-formula><mml:math id="M27" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>, higher than the
typical data acquisition rate for laboratory studies (1 <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>, with data
typically reported as 1 <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">min</mml:mi></mml:mrow></mml:math></inline-formula> averages). Voltage-scanning mode requires even higher acquisition rates and is described below.</p>
      <p id="d1e559"><italic>CIMS voltage scanning.</italic> A voltage-scanning mode is applied to examine the method for the prediction of analyte sensitivity in an iodide CIMS (Iyer
et al., 2016; Lopez-Hilfiker et al., 2016). By scanning the voltage difference
(d<inline-formula><mml:math id="M30" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>) between the skimmer of the first quadrupole and the entrance to the
second quadrupole ion guide of the mass spectrometer, the relationship between
d<inline-formula><mml:math id="M31" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> and signal fraction remaining is established and can be fit by a sigmoid
function described by a maximum possible signal (<inline-formula><mml:math id="M32" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and a signal
decay rate as a function of d<inline-formula><mml:math id="M33" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>. The voltage difference at which half the
maximum signal is removed (i.e., half the adducts that could be formed are
de-clustered) is described by a critical parameter, d<inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. This parameter
has been shown to correlate with the binding enthalpy of the iodide–molecule adduct and the analyte sensitivity in an iodide CIMS (Lopez-Hilfiker et al.,
2016). Quantification using these relationships has been previously shown to
yield results within 60 <inline-formula><mml:math id="M35" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> uncertainty in total measured carbon
(Isaacman-VanWertz et al., 2018).  Other researchers have applied variations of the voltage scan method to acetate or <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> CIMS, such as
scanning the voltage difference at seven different sections of the mass
spectrometer (Brophy and Farmer, 2016) or using the ion kinetic energy
(KE<inline-formula><mml:math id="M37" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:math></inline-formula>) instead of d<inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Zaytsev et al., 2019). These approaches all
seek to quantify instrument response empirically through variations in the
operating conditions; for this work, we follow the original approach described
by Lopez-Hilfiker et al. (2016).</p>
      <p id="d1e649">No consensus currently exists on the rate at which voltages can (or should) be
scanned, the number of spectra collected at each d<inline-formula><mml:math id="M39" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level, or the number or
range of d<inline-formula><mml:math id="M40" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> levels scanned, but previous work has demonstrated complete
voltage scans on timescales of minutes (Isaacman-VanWertz et al., 2018;
Mattila et al., 2020; Zaytsev et al., 2019). This timescale is not practical
for GC applications, in which chromatographic peak widths are typically less
than tens of seconds. Generally, the voltages need to be switched quickly enough to have multiple d<inline-formula><mml:math id="M41" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> levels across one chromatographic peak but slowly enough to reach a steady state before switching again. Data acquisition must occur
more quickly than voltage switching, with sufficient time resolution to discard any data collected during voltage transitions (i.e., non-steady-state). In this
study, these requirements were met by switching voltages at 2.5 <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula> and
acquiring data at 20 <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>. With this acquisition rate, eight
(i.e., 20 <inline-formula><mml:math id="M44" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>/2.5 <inline-formula><mml:math id="M45" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>) data points per d<inline-formula><mml:math id="M46" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> were collected, with at least the first two to three expected to be “transition spectra” that need to be ignored; practically speaking we find that only the last three to four spectra are stable (typical relative standard deviation <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M48" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>), so the
first five spectra of each level are ignored and the signal at a given d<inline-formula><mml:math id="M49" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level is taken as the average of the final three spectra collected. We note that voltage
switching and data acquisition rates are likely instrument specific, and optimal settings may vary significantly across different CIMS instruments.
Additionally, some peaks might be too small to finish a complete voltage scan
and consequently cannot yield a reasonable d<inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> unless multiple
chromatograms containing the same compounds are collected.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e753">Demonstration of the voltage scan method to the GC-CIMS with <bold>(a)</bold>
recreation of the chromatographic peak (grey dots represent all data collected at 20 <inline-formula><mml:math id="M51" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>, while the larger red dots represent the last three data points at
each d<inline-formula><mml:math id="M52" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level, which are used to calculate the signal at the given d<inline-formula><mml:math id="M53" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level) and <bold>(b)</bold> signal fraction remaining at each voltage difference (d<inline-formula><mml:math id="M54" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>). Data points in light red, excluded from the sigmoidal fit, are signals from each d<inline-formula><mml:math id="M55" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level
that do not meet quality control metrics.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f01.png"/>

        </fig>

      <p id="d1e805">The voltage settings of the CIMS in the regular mode are used as a set of
baseline values (designated as d<inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:mi>V</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M57" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula>): fourteen different sets of voltage settings, each of which has a constant voltage deviation from the
baseline values (<inline-formula><mml:math id="M58" display="inline"><mml:mo lspace="0mm">-</mml:mo></mml:math></inline-formula>0.5 to <inline-formula><mml:math id="M59" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>12 <inline-formula><mml:math id="M60" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula>). The voltage setting is varied at
2.5 <inline-formula><mml:math id="M61" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>, alternating between the baseline values and a set of voltages
representing a different d<inline-formula><mml:math id="M62" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level. The voltages upstream of the second
quadrupole moved simultaneously with the change in d<inline-formula><mml:math id="M63" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> to maintain a constant electric field gradient across the quadruples and consequently minimize
impacts on ion transmission efficiency (Lopez-Hilfiker et al., 2016). As shown
in the upper plot of Fig. 1a, the set of d<inline-formula><mml:math id="M64" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> levels is always in the same
order but is not monotonic, randomized to avoid the influence of potential memory effects on the results. An example of the output data for a signal
chromatographic peak is shown in Fig. 1a. Grey dots represent all data
collected at 20 <inline-formula><mml:math id="M65" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Hz</mml:mi></mml:mrow></mml:math></inline-formula>, while the larger red dots represent the last three
spectra at each d<inline-formula><mml:math id="M66" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level, which are used to calculate the signal at that voltage scan with the given d<inline-formula><mml:math id="M67" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level. The signal fraction remaining (SFR) is calculated
as the measured signal, <inline-formula><mml:math id="M68" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>, at a certain voltage scan, <inline-formula><mml:math id="M69" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>, of a given d<inline-formula><mml:math id="M70" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>
level, divided by the expected signal, <inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:msup><mml:mi>S</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, that would have been observed at
that scan using baseline voltages, <italic>base</italic> (here, d<inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mi>V</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M73" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula>):
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M74" display="block"><mml:mrow><mml:mtext>SFR</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msubsup><mml:mi>S</mml:mi><mml:mi>n</mml:mi><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:mi>V</mml:mi></mml:mrow></mml:msubsup></mml:mrow><mml:mrow><mml:msubsup><mml:msup><mml:mi>S</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:mi>n</mml:mi><mml:mtext>base</mml:mtext></mml:msubsup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          With direct air sampling, the signal changes sufficiently slowly that the baseline signal at a given d<inline-formula><mml:math id="M75" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level can be inferred from subsequent and following measurements at the baseline voltages, i.e., <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mtext>SFR</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msubsup><mml:mi>S</mml:mi><mml:mi>n</mml:mi><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:mi>V</mml:mi></mml:mrow></mml:msubsup></mml:mrow><mml:mrow><mml:mfrac><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">2</mml:mn></mml:mfrac><mml:mfenced close=")" open="("><mml:mrow><mml:msubsup><mml:mi>S</mml:mi><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mtext>base</mml:mtext></mml:msubsup><mml:mo>+</mml:mo><mml:msubsup><mml:mi>S</mml:mi><mml:mrow><mml:mi>n</mml:mi><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mtext>base</mml:mtext></mml:msubsup></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></inline-formula>. However,
in a chromatographic application, the signal varies so rapidly due to the rise
and fall of chromatographic peaks that such an approximation is not
necessarily reliable. Instead, the changes in the voltage settings back and forth between the baseline condition and a certain voltage difference
allow us to recreate the chromatographic peaks for sample runs in the<?pagebreak page6839?> voltage
scan mode. As shown in Fig. 1a, the signals obtained with the voltage setting
at the baseline condition are used to recreate the chromatographic peak by
fitting these points with an exponentially modified Gaussian peak, recreating
the peak shown in black in the example. The signal fraction remaining at each voltage level is calculated as the ratio of the observed signal to the recreated
peak at the same time.</p>
      <p id="d1e1059">An example of the obtained signal fraction remaining at different voltage
differences is shown in Fig. 1b. The d<inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of the compound can be obtained
by fitting the data with a sigmoidal function. Due to the fast acquisition and
voltage-scanning rate, some additional quality control metrics are necessary. Specifically, we reject data from a given voltage level if the
relative standard deviation of the three included spectra is larger than
20 <inline-formula><mml:math id="M78" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>, indicating the voltage or signal level is not stable.
Additionally, we observe that the set-point voltages are not always reached as expected, so we use the reagent ion signal (which also changes with d<inline-formula><mml:math id="M79" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>) to
evaluate whether or not a given voltage level represents the target d<inline-formula><mml:math id="M80" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>
setting. Specifically, the medians of reagent ion signals at each d<inline-formula><mml:math id="M81" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>
throughout a run cycle are used as standard values of reagent signals per
d<inline-formula><mml:math id="M82" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>, and data are rejected if their corresponding reagent signals are more
than 15 <inline-formula><mml:math id="M83" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> away from the standard value, indicating the target d<inline-formula><mml:math id="M84" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>
setting was not reached. Signals from each d<inline-formula><mml:math id="M85" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> level that do not meet these
quality control metrics (i.e., those in light red in Fig. 1b) are not included
in the sigmoidal fit. The d<inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of each compound was calculated from
duplicate samples and was excluded from analysis if found to differ by more than 50 <inline-formula><mml:math id="M87" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Experimental setup</title>
      <p id="d1e1159">The TAG-CIMS/FID is used to quantify SOA generated through gas-phase
<inline-formula><mml:math id="M88" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and/or multiple levels of OH oxidation of limonene (Sigma
Aldrich, 97 <inline-formula><mml:math id="M89" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> purity) and 1,3,5-trimethylbenzene (TMB) (Sigma
Aldrich, 98 <inline-formula><mml:math id="M90" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> purity) in a potential aerosol mass (PAM) oxidation flow reactor (OFR) (Lambe et al., 2011). For the convenience of the
discussions later, a given set of oxidation experiments is discussed as a “precursor-oxidant” (e.g., limonene-<inline-formula><mml:math id="M91" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d1e1200">Experiments were conducted at 25 <inline-formula><mml:math id="M92" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>, 40 %–50 %
relative humidity, and a constant gas flow rate of 12 <inline-formula><mml:math id="M93" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>
through the OFR.  Limonene or TMB was injected into a carrier gas of synthetic
air through use of an automated syringe pump at liquid flow rates ranging from
0.95 to 1.9 <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">h</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> or corresponding mixing ratios of
236–472 <inline-formula><mml:math id="M95" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppbv</mml:mi></mml:mrow></mml:math></inline-formula>. During ozonolysis experiments, 35 <inline-formula><mml:math id="M96" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ppmv</mml:mi></mml:mrow></mml:math></inline-formula>
<inline-formula><mml:math id="M97" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was injected at the OFR inlet.  During photooxidation
experiments, OH and <inline-formula><mml:math id="M98" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">HO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> were generated via  <inline-formula><mml:math id="M99" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>
photolysis at 254 and 185 <inline-formula><mml:math id="M100" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>; over the range of conditions that were
used, the estimated OH exposures in the OFR were in the range of (<inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:mn mathvariant="normal">4</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">10</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:mn mathvariant="normal">7</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">11</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) <inline-formula><mml:math id="M103" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">molecules</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (Rowe et al.,
2020).</p>
      <p id="d1e1375">Between sampling from the flow reactor, liquid standards were introduced into
the sample collection cell using the automated liquid standard injector on the TAG. Standards analyzed included 1,12-dodecanediol (Sigma Aldrich, 99 <inline-formula><mml:math id="M104" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> purity), vanillin (Sigma Aldrich, 99 <inline-formula><mml:math id="M105" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> purity),
undecanoic acid (AccuStandard, 100 <inline-formula><mml:math id="M106" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> purity), hexadecanoic acid
(AccuStandard, 100 <inline-formula><mml:math id="M107" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> purity), levoglucosan (Sigma Aldrich,
99 <inline-formula><mml:math id="M108" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> purity), and an <inline-formula><mml:math id="M109" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-alkanes mixture
(<inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math id="M111" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">40</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, AccuStandard, 50 <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">g</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">mL</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>).</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Data analysis</title>
      <p id="d1e1475">CIMS and FID chromatograms are collected as individual files in each GC run
cycle. For each cycle, elemental formulas are identified through the
high-resolution fitting of peaks in the mass spectra using the Tofware
(Tofwerk, AG and Aerodyne Research, Inc., version 3.1.2) toolkit developed for
the IGOR Pro 7 analysis software package (Wavemetrics, Inc.). The
chromatograms (i.e., time-series data) of identified formulas in CIMS as well
as the FID chromatograms<?pagebreak page6840?> are then imported into TERN, the freely available (<uri>https://sites.google.com/site/terninigor/</uri>, last access: 26 May 2021)
Igor-based software tool for the quantification of chromatographic data
(Isaacman-VanWertz et al., 2017), with custom modifications to analyze voltage-scanning data. Integration of CIMS peaks yields units of
CIMS-response <inline-formula><mml:math id="M113" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> s, where CIMS response is ions s<inline-formula><mml:math id="M114" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (i.e., counts per
second, “cps”) normalized to the number of reagent ions (typically in
millions). CIMS peak areas are therefore in the units of (ions per million reagent
ions) s<inline-formula><mml:math id="M115" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> <inline-formula><mml:math id="M116" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> s <inline-formula><mml:math id="M117" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> ions per million reagent ions. Normalization to the
reagent ion was not used for generating voltage-scanning curves, following the published approach (Lopez-Hilfiker et al., 2016).</p>
      <p id="d1e1527"><italic>Quantification by FID.</italic> Analytes are quantified by integrating
chromatographic peaks detected by the FID. Sensitivity of the FID to an
oxygenated organic compound is estimated based on its elemental formula,
identified by the CIMS, as described by Hurley et al. (2020). In brief, FID
detection of hydrocarbons provides a near-universal response per unit carbon
mass, which is easily obtained by a multi-point calibration to a
hydrocarbon. The average response to carbon in oxygenates decreases
proportionally to the oxygen-to-carbon ratio (<inline-formula><mml:math id="M118" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">O</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>) of the compound. Though the
exact decrease in response is driven by the chemical functional groups
present, Hurley and co-workers have shown that per-carbon FID sensitivity can
be estimated from <inline-formula><mml:math id="M119" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">O</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> to within approximately 20 <inline-formula><mml:math id="M120" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> uncertainty for
an individual analyte. We therefore calculate the mass or number of moles of
an analyte from its FID peak area based on a calibration response factor to
<inline-formula><mml:math id="M121" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-alkanes, with a correction for oxygenation based on the elemental formula
identified by CIMS (specifically, the FID response per carbon atom relative to
<inline-formula><mml:math id="M122" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-alkanes <inline-formula><mml:math id="M123" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.54</mml:mn><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mrow class="chem"><mml:mi mathvariant="normal">O</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">C</mml:mi></mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">0.99</mml:mn></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math id="M124" display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">O</mml:mi><mml:mo>/</mml:mo><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> is the oxygen-to-carbon ratio in the target analyte, Hurley et al., 2020). The sensitivity of an analyte in
CIMS, ions generated per mole introduced per million reagent ions, can be
determined by dividing its CIMS peak area (ions per million reagent ions) by the
number of moles calculated based on the FID peak, yielding units of
ions per mole per million reagent ions. Due to the peak integration, this unit is
atypical in the CIMS scientific community.  Therefore, we also provide a
conversion of this unit to the more common metric of CIMS sensitivity,
cps per ppt per million reagent ions, based on a specific CIMS operating condition
(i.e., 100 <inline-formula><mml:math id="M125" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mbar</mml:mi></mml:mrow></mml:math></inline-formula> in IMR, a 2 <inline-formula><mml:math id="M126" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> sample flow rate, and a 2 <inline-formula><mml:math id="M127" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> reagent ion flow rate). The detailed method of unit conversion
is described in the Supplement but essentially involves a conversion by the number of moles entering the instrument per time for a given
ppt and flow rate. In the analyses presented here, the sensitivity of an
analyte is calculated in three different samples to avoid potential artifacts
from data analysis; these three samples represent triplicate samples for the
limonene-<inline-formula><mml:math id="M128" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> experiment and three different OH oxidation levels for the precursor-OH experiments. To avoid potential errors introduced by poor
chromatographic resolution, low signal, or other issues, we exclude from the
analysis any analytes for which the sensitivity calculated from the three
samples have a relative standard deviation greater than 50 <inline-formula><mml:math id="M129" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>. It is
critical to note that, because the FID is a single-channel detector,
quantification by FID is only possible for peaks that are sufficiently
well resolved to be confidently integrated and is not available for every peak observed by CIMS.</p>
      <p id="d1e1659">Since the determination of analyte sensitivities relies on both CIMS and FID
peak area, it is crucial to make sure that the peaks of analyte from CIMS and
FID are correctly aligned. To align peaks of the same compounds between CIMS
and FID in chromatograms, retention times are corrected based on the linear
regression of retention times of internal standards (i.e., vanillin and
1,12-dodecandiol) as well as the two largest peaks. We reject compounds that have differences in peak retention time between CIMS and FID more than
2 <inline-formula><mml:math id="M130" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> after the retention time correction. We also reject compounds that
have significant differences in peak shapes between CIMS and FID.</p>
      <p id="d1e1670">Instrument blank runs (i.e., runs without sample collection and liquid
standard injections) are conducted prior to each oxidation experiment to make
sure that there are no visible chromatographic peaks that can interfere with
the data analysis later. Blank runs are also tested every five sample runs to
check for carry-over or residuals of compounds within the instrument and that no carry-overs of analytes are detected. Additionally, triplicate sample runs are
conducted to test for the stability and repeatability of the TAG-CIMS/FID. The
results suggest that the relative standard deviations of signals in triplicate runs are within 15 <inline-formula><mml:math id="M131" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for CIMS and FID.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Variability in isomer sensitivity</title>
      <p id="d1e1697">As an example of the data, Fig. 2b shows the chromatograms of the ion
<inline-formula><mml:math id="M132" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">14</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> from a sample of aerosol collected in the
limonene-OH experiment. The FID abundance (<inline-formula><mml:math id="M133" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axis of Fig. 2a is a
single-channel signal of total ions produced by the mass of carbon combusted; Holm, 1999), so each analyte (i.e., chromatographic peak eluting at a given
retention time), responds with similar mass-based sensitivity. Co-eluting peaks are not well resolved and may not be able to be accurately integrated, as
there is no additional dimension of separation (e.g., mass spectra) to improve
resolution beyond what is shown. In contrast, CIMS signals include separation
by mass of detected ions, so co-eluting analytes of different elemental
formulas can be easily resolved.  The chromatogram displayed, Fig. 2b, is the
normalized ion count signals of a single ion,
<inline-formula><mml:math id="M134" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">14</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. Five isomers, highlighted with numbers in
Fig. 2b, were able to be matched to FID peaks to calculate sensitivities with
relative standard deviations less than 50 <inline-formula><mml:math id="M135" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>. While larger peaks can
be easily correlated between the FID and CIMS by retention time,<?pagebreak page6841?> compounds
with small peak areas such as Compounds 3 and 4 in Fig. 2b are also correlated when their peak shapes between FID and CIMS are similar and they have
comparable behavior across different oxidation levels to ensure the proper
peak assignment. As an example, Fig. S1 in the Supplement shows the peaks representing Compounds
3 and 4, which have the same retention time and peak shape in the CIMS and FID
and follow the similar trends with the change in OH exposure levels.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e1777">An example of isomers quantified in <bold>(b)</bold> the chromatogram of ion <inline-formula><mml:math id="M136" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">14</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in CIMS with <bold>(a)</bold> their corresponding FID peaks (highlighted in red). The peaks marked with numbers are those included in the analysis of isomer sensitivity.</p></caption>
          <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f02.png"/>

        </fig>

      <p id="d1e1822">Given that the FID sensitivity of oxygenated organics is primarily a function
of carbon and oxygen content (to within <inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M138" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula>) (Hurley
et al., 2020) and that these isomers all have the same elemental formula, FID peak areas (highlighted in red in Fig. 2a) are proportional to the number of moles
of those compounds. Differences in sensitivity are qualitatively clear: for example, Compounds 2 and 3 have a relatively similar number of moles in the sample (i.e., similar FID areas) yet show at least 1 order of magnitude difference in CIMS response. The CIMS sensitivities of the five compounds can
be quantified as discussed and are found to span the range from <inline-formula><mml:math id="M139" display="inline"><mml:mrow><mml:mn mathvariant="normal">3.1</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">16</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> ions per mole per million reagent ions (Compound 1) to <inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:mn mathvariant="normal">6.5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">14</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> ions per mole per million reagent ions (Compound 3). The 2 orders of magnitude range of sensitivities of the five identified isomers shows that, while sharing the same elemental formula, isomers may have significantly different CIMS
sensitivities. These differences may result in biases during quantification
when using a direct-air-sampling CIMS without GC pre-separation that provides
resolution of isomers.</p>
      <p id="d1e1874">Notably, although this instrument TAG-CIMS/FID is specifically configured to
collect only particle-phase samples, this calibration technique for
quantifying CIMS sensitivity could be applied to gas-phase samples using a
different instrument configuration and should be applicable to any GC-based
instrument employed upstream of the two detectors as long as the analyte can
be collected by the upstream instrument, separated by the GC column, and
transferred to both detectors. Additionally, the coupled TAG-CIMS/FID can be
applied to investigate the change in isomer composition with the increase in OH levels in future studies. It is possible that the isomers of a formula
produced at higher OH levels are more oxidized compounds, thus changing the isomer distributions in the formula. In this case, the average sensitivity of
the formula will likely increase at higher OH levels.</p>
      <p id="d1e1877">Calibration of CIMS using FID requires the target analyte to be detected by
both detectors and to have a well-resolved chromatographic peak in FID. For example, there are certainly other isomers (i.e., chromatographic peaks) in
Fig. 2b besides the highlighted five ones. However, some of those isomers are
not included in the discussion because no FID peaks or well-resolved FID peaks
are present at the same retention time as their CIMS peaks.  Conversely, it is
possible that some of the FID peaks are isomers of this formula that are not
detectable by CIMS. Due to the higher chemical resolution of the CIMS, the
number of isomers available for intercomparison is primarily limited by the
chromatographic resolution of the FID since FID is a single-channel detector. This limitation can be mitigated by collecting data under a wide
range of conditions or environments. Once the CIMS sensitivity of a compound
is obtained, quantification can be achieved for those compounds in other
poor-signal conditions or even without the coupling of the FID.</p>
      <p id="d1e1880">Additionally, the use of a GC column, which is selective towards a certain
range of volatility and polarity of compounds, limits the detection to
specific ranges of compounds and/or could induce thermal decomposition of some sampled compounds to form analytes not present in the original sample
(Isaacman-VanWertz et al., 2016).  Nevertheless, quantification of individual
analytes can be critical for understanding source and chemical pathways
(Nozière et al., 2015) and can provide fundamental insight into the capabilities and limitations of a given ion reagent chemistry. Furthermore,
while decomposition during analysis may impact the scientific interpretation
of the collected sample, decomposition is expected to primarily occur during
desorption or GC analysis and is therefore upstream of the detectors; both
detectors consequently “see” the same analyte whether or not decomposition
occurs, and it does not impact measurements of CIMS sensitivity of the
molecules that do reach the detectors. It is well established that sensitivity is humidity dependent for many chemicals in an iodide CIMS (Lee et al.,
2014). Because analytes entering the IMR come from the GC in a dry helium
flow, the relative humidity in the IMR is stable and can be controlled by
adjusting the mixed water vapor in the reagent ion flow. Therefore, the
coupled TAG-CIMS/FID provides opportunities for future work to quantitatively
investigate the humidity dependency of sensitivity of those chemicals.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3" specific-use="star"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e1885">Sensitivities of constituent isomers of formulas for which at
least two isomers had sensitivities obtained in the oxidation experiments.
Each circle shows the sensitivity of an isomer, and the area of the circle represents the mole fraction of the isomer in the formula. Boxes represent the first to third quartiles. Black lines are the median values of the sensitivities.
<inline-formula><mml:math id="M141" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula>: unit converted for direct-air-sampling CIMS using 100 <inline-formula><mml:math id="M142" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mbar</mml:mi></mml:mrow></mml:math></inline-formula> in IMR, 2 <inline-formula><mml:math id="M143" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula>
sample flow rate, and 2 <inline-formula><mml:math id="M144" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> reagent ion flow rate.</p></caption>
          <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f03.png"/>

        </fig>

      <p id="d1e1927">To systematically study the variance of isomer sensitivity, formulas with
multiple isomers identified in the oxidation experiments are summarized in
Fig. 3 (as noted above, only isomers with sensitivities with less than 50 <inline-formula><mml:math id="M145" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> relative standard deviation in three samples are
included). The results suggest that the sensitivity of isomers typically vary
by 1 order of magnitude, with a maximum deviation of 2 orders of magnitude, for instance, in the case of <inline-formula><mml:math id="M146" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">12</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in limonene-<inline-formula><mml:math id="M147" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M148" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">14</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in limonene-OH (also shown
in Fig. 2), and <inline-formula><mml:math id="M149" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">12</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in TMB-OH. In a minority of
cases, sensitivities vary by only a factor of 2 to 4 (e.g., <inline-formula><mml:math id="M150" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">16</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in limonene-<inline-formula><mml:math id="M151" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>,
<inline-formula><mml:math id="M152" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">14</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in limonene-OH, and
<inline-formula><mml:math id="M153" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">14</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in TMB-OH). Notably, molecules of the same
formula produced through two different chemistries (e.g.,
<inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">14</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in limonene-OH and TMB-OH) also differ to
approximately the same degree, supporting the conclusion that a measured
formula may consist of a different set of isomers depending on the sampling
environment. The significant variance of isomer sensitivity indicates that if
a CIMS with direct air sampling is used, the concentration of a given formula
may be significantly biased towards the<?pagebreak page6842?> concentration of the most sensitive
isomer within the formula, while other isomers, which could actually be more abundant on a per-mole basis, may be overwhelmed. As an example, consider
<inline-formula><mml:math id="M155" display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">12</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>)</mml:mo><mml:msup><mml:mi mathvariant="normal">I</mml:mi><mml:mo>-</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in the limonene-<inline-formula><mml:math id="M156" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> experiment, which
includes a low-sensitivity, high-concentration isomer and a high-sensitivity, low-concentration isomer. The low-concentration isomer is approximately
<inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:mn mathvariant="normal">80</mml:mn><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> more sensitive but <inline-formula><mml:math id="M158" display="inline"><mml:mrow><mml:mn mathvariant="normal">5</mml:mn><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> less abundant (represented by the ratio of the marker area in Fig. 3) than the high-concentration isomer. In
this example, <inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">95</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M160" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the CIMS signal is from an isomer that accounts for less than 20 <inline-formula><mml:math id="M161" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of the mass, which could introduce biases
in data interpretation (if, for instance, the two isomers can come from
different sources or represented different chemistries). The example demonstrates that isomer resolution, achieved by coupling a CIMS with a GC and
a FID, consequently provides not only additional detail about a sample, but is
also critical for the quantification of less sensitive isomers.</p>
</sec>
<?pagebreak page6843?><sec id="Ch1.S3.SS2">
  <label>3.2</label><?xmltex \opttitle{Prediction of sensitivity using d$V_{{50}}$}?><title>Prediction of sensitivity using d<inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></title>
      <p id="d1e2278">Previous work has shown a log-linear relationship between sensitivity and
d<inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. However, these relationships were established based on only a
limited number of chemical standards, mostly mono- and di-acids (Brophy and
Farmer, 2016; Iyer et al., 2016; Lopez-Hilfiker et al., 2016), and demonstrate
significant scatter around the trend. In this work, the quantification of
compounds based on FID response allows us to broaden the investigation of this
relationship from liquid standards to oxidation products. Of all observed
analytes, sensitivities calculated for a total of 63 oxidation products and 3
liquid chemical standards passed all the data quality checks for inclusion in
this analysis (i.e., sufficient FID resolution for quantification, relative
standard deviations of sensitivity less than 50 <inline-formula><mml:math id="M164" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for triplicate
(limonene-<inline-formula><mml:math id="M165" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) or three different OH level measurements, relative standard deviations of d<inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> less than 50 <inline-formula><mml:math id="M167" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> for duplicate
measurements). The calculated sensitivities of all 66 compounds and their
d<inline-formula><mml:math id="M168" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> obtained using the voltage scan method are plotted in Fig. 4.
Sensitivities of analytes included in the discussion vary across 3 orders of magnitude. A plateau of sensitivity, which is an indication of maximum
sensitivity, is observed for compounds with d<inline-formula><mml:math id="M169" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> greater than 7 <inline-formula><mml:math id="M170" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula>.
Levoglucosan, which is known to be detected at the collision limit
(Lopez-Hilfiker et al., 2016), is one of the compounds that nearly reach the
maximum sensitivity in this study. The finding agrees with those reported in
the literature that the maximum sensitivity can be reached if the
iodide–molecule reaction is only limited by the formation rate (i.e., collision limit) (Huey et al., 1995).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e2359">Relationship between sensitivities and d<inline-formula><mml:math id="M171" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of compounds
identified in oxidation experiments as well as liquid standards. Each data
point is a compound identified with the marker area representing the moles
of the compound. The error bars on the <inline-formula><mml:math id="M172" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axis are the standard deviation of sensitivity in triplicate (limonene-<inline-formula><mml:math id="M173" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) or three different OH level
measurements (limonene-OH and TMB-OH). The error bars on the <inline-formula><mml:math id="M174" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis are the standard deviation of d<inline-formula><mml:math id="M175" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in duplicate measurements. <inline-formula><mml:math id="M176" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula>: unit converted for direct-air-sampling CIMS using 100 <inline-formula><mml:math id="M177" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mbar</mml:mi></mml:mrow></mml:math></inline-formula> in IMR, 2 <inline-formula><mml:math id="M178" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula>
sample flow rate, and 2 <inline-formula><mml:math id="M179" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> reagent ion flow rate.</p></caption>
          <?xmltex \igopts{width=312.980315pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f04.png"/>

        </fig>

      <p id="d1e2449">The observed plateau of sensitivity is in the range expected for maximum
sensitivity (calculated in the Supplement) based on instrument
operating conditions; the colored grey bar in Fig. 4 spans the range from the calculated kinetic-limited maximum sensitivity to 4 times lower values
(observed by Isaacman-VanWertz et al. (2018) to be the maximum sensitivity
using an instrument of the same design as that used here). The right axis
provides a direct mathematical conversion between the left axis and more
typical CIMS units assuming a sample flow of 2 <inline-formula><mml:math id="M180" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> (as opposed to the
0.7 <inline-formula><mml:math id="M181" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">sccm</mml:mi></mml:mrow></mml:math></inline-formula> used here). It provides a general context for the conversion between the units but is not fully representative of the conversion due to differences in flow between our setup and typical operation and its
concomitant impacts on the residence time within the reaction region. While
the detailed analysis is in the Supplement, true maximum sensitivity under our IMR conditions but with typical flows is found to be
88 cps per ppt per million reagent ions (not 350 as implied in Fig. 4). For this
large set of individual analytes, the relationship between sensitivity and
d<inline-formula><mml:math id="M182" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> shown by Iyer et al. (2016) and Lopez-Hilfiker et al. (2016) is not so clear. A log-linear relationship defines an apparent upper bound of
sensitivity, but approximately one-quarter of compounds (dashed region) have
sensitivities substantially lower than this relationship. These results
suggest that, for calibrating individual components, the log-linear relationship between sensitivity and d<inline-formula><mml:math id="M183" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> may provide some rough
indications of sensitivity but is fairly imprecise.</p>
      <p id="d1e2491">The data shown in Fig. 4 are inherently different than the data from a typical, direct-air-sampling application of CIMS in ways that could impact the
application of the relationship between sensitivity and d<inline-formula><mml:math id="M184" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.
Direct-air-sampling CIMS classifies analytes on an elemental formula basis, while a TAG-CIMS can differentiate isomers and provide quantification down to the
isomer resolution. The analytes significantly deviating from the log-linear relationship are mostly less sensitive compounds. For CIMS with direct air sampling, the responses of the less sensitive isomers might be overwhelmed by
the signals of more sensitive isomers of the same formula.  Such an outcome
would potentially strengthen the observed log-linear relationship but would
underestimate the observed mass of that compound (and consequently
formula). To examine the applicability of the voltage scan method to CIMS operated with direct air sampling, we convolute resolved isomers into their
elemental formulas. The sensitivity of a formula is calculated as the average
of isomer sensitivities weighted by their number of moles, while the d<inline-formula><mml:math id="M185" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
of a formula is calculated as the average of d<inline-formula><mml:math id="M186" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> weighted by their CIMS
abundance (i.e., chromatographic peak area in CIMS data). Note that the
signal-weighted method to calculate formula-based d<inline-formula><mml:math id="M187" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is found to yield
reasonable approximations of the true d<inline-formula><mml:math id="M188" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and the detailed discussions are in the Supplement. The result of averaging and weighting each
parameter in these ways recreates how that formula would respond in
direct-air-sampling CIMS if it had the same isomer composition; we note that a
direct comparison cannot be made by a simple direct air sample of the same
mixture due to artifacts introduced by the GC (both positive – the formation
of new compounds through thermal decomposition – and negative – the inability to elute highly polar compounds). To ensure averaged formulas are a reasonable
representation of a hypothetical direct-air CIMS sample, formulas are removed
from the analysis if (1) the formula has only two isomers and one of the
isomers does not have a calculated sensitivity and/or (2) the isomer with the most abundant CIMS signal does not have a reported sensitivity. The resulting
relationship between sensitivity and d<inline-formula><mml:math id="M189" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> on a per-formula basis can be plotted (Fig. 5). The compounds that are filtered by these criteria are not
statistically significantly different from the compounds that pass these
criteria (one-way analysis of variance – ANOVA – test, <inline-formula><mml:math id="M190" display="inline"><mml:mrow><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.36</mml:mn></mml:mrow></mml:math></inline-formula>, and 0.71 for log-transformed sensitivity and d<inline-formula><mml:math id="M191" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, respectively).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e2586">Sensitivity vs. d<inline-formula><mml:math id="M192" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> on a per-formula basis with a linear regression on the formulas.
<inline-formula><mml:math id="M193" display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula>: unit converted for direct-air-sampling CIMS using 100 <inline-formula><mml:math id="M194" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mbar</mml:mi></mml:mrow></mml:math></inline-formula> in IMR, a 2 <inline-formula><mml:math id="M195" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> sample flow rate, and a 2 <inline-formula><mml:math id="M196" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">slpm</mml:mi></mml:mrow></mml:math></inline-formula> reagent ion flow rate.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f05.png"/>

        </fig>

      <p id="d1e2639">As shown in Fig. 5, the log-linear relationship improves when considered on a
per-formula basis, though significant scatter remains. Linear regression for
formulas of d<inline-formula><mml:math id="M197" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">7</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">V</mml:mi></mml:mrow></mml:math></inline-formula> (i.e., having lower than maximum
sensitivity) has a reasonable correlation (<inline-formula><mml:math id="M199" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.77</mml:mn></mml:mrow></mml:math></inline-formula>), with a decrease of 0.6 log units (i.e., a factor of 10<inline-formula><mml:math id="M200" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0.6</mml:mn></mml:msup></mml:math></inline-formula>) of sensitivity per volt change in
d<inline-formula><mml:math id="M201" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. This slope is similar to, but slightly shallower than, the<?pagebreak page6844?> slope
observed in previous work of 0.9 log units per volt (Lopez-Hilfiker et al.,
2016).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e2702">Measured moles of <bold>(a)</bold> compounds and <bold>(b)</bold> formulas (i.e., summation of
isomers within each formula) in all oxidation experiments vs. their fitted
moles using the linear regression equation obtained in Fig. 5.</p></caption>
          <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f06.png"/>

        </fig>

      <p id="d1e2717">The goal of the voltage scan calibration approach is to predict the
sensitivities of analytes without conducting individual calibrations with
chemical standards in permeation tubes. To quantify the error introduced in
this approach, we use the fitted linear regression equation in Fig. 5 to
calculate a sensitivity for each compound based on its observed d<inline-formula><mml:math id="M202" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.  As
described by Bi et al. (2021a), sensitivity predicted in the log-linear-based calibration method is inherently biased, and the bias can be corrected based on residual scatter around the nominal relationship,
<inline-formula><mml:math id="M203" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>scatter</mml:mtext><mml:mtext>eff</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula>; given that the calculated <inline-formula><mml:math id="M204" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>scatter</mml:mtext><mml:mtext>eff</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula> of a residual is 0.22, predicted
sensitivities are expected to by biased low by a factor of 1.14 and so are adjusted by that factor here. In Fig. 6a, the moles of each compound
calculated using the fit from their d<inline-formula><mml:math id="M205" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (“fitted moles”) are compared to the measured moles calculated using the FID data.  Compounds that were filtered out of Fig. 5 using the criteria described above are included in the results
shown in Fig. 6. By including compounds not used to generate the linear
relationship, this approach therefore provides a more realistic and
conservative evaluation of the approach. The results show that about
60 <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> and 80 <inline-formula><mml:math id="M207" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of compounds are estimated within factor of 3 and 10 uncertainties, respectively, indicating that the voltage scan
approach has high uncertainties for individual components. The uncertainty for
individual compounds found in this work is similar to the studies originally
proposing this log-linear relationship (i.e., 77 <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> and
85 <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> of compounds are estimated within factor of 3 and 10 uncertainties, respectively) (Iyer et al., 2016). The uncertainty is likely
caused by the transfer of uncertainty from the empirical correlation itself
and the consideration of a wider range of chemical species. It is also possible that optimizing certain instrumental parameters could improve the accuracy of
the voltage-scanning method, but future work is needed to investigate the optimization method further.  Additionally, to examine the accuracy of the
predictions for a direct-air-sampling CIMS, we compare the fitted moles with
the measured moles on a per-formula basis (i.e., the<?pagebreak page6845?> summation of moles of isomers within each formula) in Fig. 6b. Most of the formulas are estimated
within factor of 3 uncertainties. Notably, a factor of 3 is in approximate agreement with the uncertainty previously estimated for individual components
quantified by iodide CIMS voltage scanning (Isaacman-VanWertz et al., 2018).</p>
      <p id="d1e2802">Because the log-linear relationship of voltage scanning provides a reasonable
central tendency, its application does not introduce significant bias for
quantifying the summation of a class of compounds. The predicted total moles
of compounds measured agree well with the measured total moles (shown as
rectangular markers in Fig. 6a, with errors within 30 <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> within an
oxidation system and for all oxidation systems combined), although predicted
moles of individual compounds have relatively high errors. The finding agrees with earlier statistical analysis suggesting that the summation of multiple
analytes with high scatters of sensitivity around a nominal relationship can
reduce uncertainty (Bi et al., 2021a) and is in qualitative agreement with the finding by Isaacman-VanWertz et al. (2018) that uncertainty in the sum of
ions was substantially lower than uncertainty in an individual analyte. We
conclude that, although using voltage scanning introduces high error into the
estimation of sensitivity for individual compounds, the approach provides a
reasonable estimate of the summed abundance.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Implications of the retention time index</title>
      <p id="d1e2821">The use of a GC expands the data with another dimension, retention time, which
is generally governed by the polarity and vapor pressure of the compound and
could potentially provide additional information to inform estimation of CIMS
sensitivity. Since a GC column with a polar stationary phase is used in the
TAG-CIMS/FID, we expect the compound with high polarity and/or low vapor
pressure to have longer retention time in the chromatogram.  Polarity and vapor pressure are not fully independent: the presence of polar functional groups (e.g., hydroxyl and carboxyl groups) tends to accompany larger
decreases in vapor pressure than less polar groups (e.g., carbonyl groups)
(Kroll and Seinfeld, 2008). Retention time is therefore expected to also
positively correlate with iodide CIMS sensitivity, which generally increases
with the presence of polar functional groups (Lee et al., 2014). To examine
the hypothesis, we plot the relationship between sensitivity and retention
index for compounds identified in oxidation experiments in Fig. 7 (retention
index <inline-formula><mml:math id="M211" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> retention time of an analyte adjusted such that <inline-formula><mml:math id="M212" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-alkanes are
defined to elute at spacings of 100 units; Onuska and Karasek, 1984). The results suggest that there is a qualitative linear trend between
log(sensitivity) and retention time index, particularly for analytes with
higher abundances. Binning the data into equally distributed groups (octiles)
reveals the tendency for later retention times to accompany higher
sensitivity. Specifically, the latest eluting two bins are more sensitive than
the earliest eluting two bins with statistical significance of <inline-formula><mml:math id="M213" display="inline"><mml:mrow><mml:mi>p</mml:mi><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula> using
a Wilcoxon signed-rank test; differences between intermediate bins are not
statistically significant. A major driver of retention time is molecule size
(e.g., number of carbon atoms), which does not necessarily impact iodide CIMS
sensitivity.  Consequently, the coarseness and scatter of the relationship
between retention time and iodide CIMS sensitivity may be due to the
concurrent impacts on retention time of polarity and vapor pressure.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><?xmltex \currentcnt{7}?><?xmltex \def\figurename{Figure}?><label>Figure 7</label><caption><p id="d1e2852">Relationship between sensitivities and retention time index of all
compounds in oxidation experiments. Black markers are all data equally
divided into eight bins based on the ranking of their sensitivity and
retention time index, centered on averages with error bars representing the
standard deviation of sensitivity and retention time index. The size of the
round marker represents the number of moles of each compound.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f07.png"/>

        </fig>

      <p id="d1e2861">To better isolate the effects of polarity in the relationship between
retention time and vapor pressure, we attempt to constrain molecule size. By
examining differences between retention times of compounds with a given
elemental formula, the effects of molecular structure and differences in
chemical functionality can be separated from some of the features that impact
vapor pressure (number of carbon atoms, molecular weight, etc.). If two
isomers have a similar chemical structure and functional group, their retention time should<?pagebreak page6846?> be relatively close due to the minor differences in vapor pressure
and polarity, and their iodide CIMS sensitivity is likely to be roughly
similar. Conversely, an isomer with a higher retention time index is expected
to contain more polar functional groups, which are also expected to have a
large impact on vapor pressure. To test this hypothesis, we compare the
sensitivities and retention index of all isomer pairs (i.e., for a formula of
<inline-formula><mml:math id="M214" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> isomers, there are <inline-formula><mml:math id="M215" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>×</mml:mo><mml:mo>(</mml:mo><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> unique isomer pairs). For each isomer
pair, we calculate the difference between the log(sensitivity) of the later-
vs. earlier-eluting isomers and compare it to their difference in retention index, shown in Fig. 8. Eight equally distributed bins (octiles) are included in Fig. 8 to better identify trends and allow statistical
comparisons. Qualitatively, it is apparent that isomers with small differences
in retention time vary widely in their sensitivities, frequently differing by
1 order of magnitude, while later-eluting isomers tend to have higher sensitivities. Isomers that elute substantially later (octiles 5–8) have
statistically higher sensitivities by, on average, roughly half an order of magnitude (a factor of 3 to 4). Conversely, there is no statistical difference
in the sensitivities of isomers with retention indices within <inline-formula><mml:math id="M216" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">300</mml:mn></mml:mrow></mml:math></inline-formula> of
each other (octiles 1–4). In other words, while iodide CIMS sensitivity of isomers with similar retention times is not a strong function of retention time, later elution does indicate some tendency for higher sensitivity,
presumably driven by the presence of higher-polarity functional groups.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8"><?xmltex \currentcnt{8}?><?xmltex \def\figurename{Figure}?><label>Figure 8</label><caption><p id="d1e2908">The relationship between differences (<inline-formula><mml:math id="M217" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula>) in
log(sensitivity) and retention index for all pairs of isomers with a given
formula. Black markers are all data equally divided into eight bins
(octiles) centered on averages with error bars representing standard deviations.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/6835/2021/amt-14-6835-2021-f08.png"/>

        </fig>

      <p id="d1e2924">While the analysis here does not provide a sufficiently deep understanding of
the relationship between sensitivity and column retention to produce a
quantitative approach for estimating sensitivity, it does demonstrate an
approach by which interactions with the GC column can provide insight into
iodide CIMS sensitivity. These data suggest that the properties of a molecule
that drive iodide CIMS sensitivity are correlated, but not tightly, with the
properties that drive the retention time of this particular GC stationary phase. Future detailed studies and physicochemical modeling of the column
retention of analytes could make use of these relationships to better
understand the factors driving sensitivity and selectivity of a given CIMS
reagent ion chemistry.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e2936">By coupling a TAG simultaneously to a FID and an iodide CIMS, we quantify
isomer-resolved CIMS sensitivity (i.e., CIMS signal divided by the number of
moles of analytes quantified using FID signal) for liquid standards as well as
oxidation products for which commercial chemical standards are not
available. The variance of isomer sensitivities for oxidation products in an
iodide CIMS is found to be generally 1 order of magnitude and up to 2 orders of magnitude. The wide range of isomer sensitivities indicates that if
an iodide CIMS with direct air sampling is used, measurements of formulas are
likely to minimize the contributions of certain (likely less polar)
isomers. The concentration of a given formula would be expected to be biased
towards the concentration of the most sensitive isomer within the formula,
even in cases where this isomer is not the most abundant.</p>
      <p id="d1e2939">We then investigate the previously reported log-linear calibration
relationship between iodide CIMS sensitivity and d<inline-formula><mml:math id="M218" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> by applying the
relationship to a broader range of chemicals including oxidation products.  We
find that estimating<?pagebreak page6847?> sensitivity of a given compound from its declustering
voltage (i.e., d<inline-formula><mml:math id="M219" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mn mathvariant="normal">50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) carries high uncertainties (0.5 to 1 order of magnitude). However, the voltage scan approach to calibration can be used to
estimate aggregate/summed moles of all analytes with low error (<inline-formula><mml:math id="M220" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">30</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M221" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">%</mml:mi></mml:mrow></mml:math></inline-formula> differences between predicted and measured moles) since
summing multiple analytes statistically reduced the uncertainty in the sum (Bi
et al., 2021a). These results imply that in the interpretation of
direct-air-sampling CIMS data, quantification based on declustering voltage is
highly uncertain for individual compounds and relatively uncertain for
individual formulas. Nevertheless, a nominal voltage-scanning relationship built using elemental formulas represents a central tendency and can be used
to estimate total mass or moles reasonably well.</p>
      <p id="d1e2982">We further find that the additional dimension of GC retention time provides
some possible advantages to understand iodide CIMS sensitivity. There exists a
positive relationship between retention time in the GC column and iodide CIMS sensitivity, but the relationship is not yet sufficiently well understood to become quantitatively useful. Future work is needed to investigate the relationship between GC retention time and iodide CIMS sensitivity.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e2990">All raw and processed data collected as part of this project are available upon request, which can be sent to Chenyang Bi (chenyangbi@vt.edu) or Gabriel Isaacman-VanWertz (ivw@vt.edu).</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e2993">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-14-6835-2021-supplement" xlink:title="pdf">https://doi.org/10.5194/amt-14-6835-2021-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e3002">CB led the instrumentation design, experimental setup, and consequent data analysis under the guidance of GIVW. GIVW, JEK, BML, and MRC
contributed to the development of the theory of the described approach.
GIVW, GOF, JEK, JTJ, and DRW contributed to hardware design and
instrumentation. JEK, WX, ATL, and MSC contributed to data collection and analysis. CB prepared the manuscript with contributions from all the authors.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e3008">Jordan E. Krechmer, Megan S. Claflin, Wen Xu,
Andrew T. Lambe, John T. Jayne, Douglas R. Worsnop, Brian M. Lerner, and
Manjula R. Canagaratna are employed by Aerodyne Research,
Inc., which commercializes TAG and CIMS instruments for geoscience
research.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e3014">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e3020">We would like to thank the Alfred P. Sloan Foundation Chemistry of the Indoor Environment Program for supporting this work.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e3025">This research has been supported by the Alfred P. Sloan Foundation (grant no. P-2018-11129).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e3031">This paper was edited by Bin Yuan and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><?label 1?><mixed-citation>Aljawhary, D., Lee, A. K. Y., and Abbatt, J. P. D.: High-resolution chemical ionization mass spectrometry (ToF-CIMS): application to study SOA composition and processing, Atmos. Meas. Tech., 6, 3211–3224,  <ext-link xlink:href="https://doi.org/10.5194/amt-6-3211-2013" ext-link-type="DOI">10.5194/amt-6-3211-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><?label 2?><mixed-citation>Arangio, A. M., Tong, H., Socorro, J., Pöschl, U., and Shiraiwa, M.: Quantification of environmentally persistent free radicals and reactive oxygen species in atmospheric aerosol particles, Atmos. Chem. Phys., 16, 13105–13119,  <ext-link xlink:href="https://doi.org/10.5194/acp-16-13105-2016" ext-link-type="DOI">10.5194/acp-16-13105-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><?label 3?><mixed-citation>Atkinson, R.: Atmospheric chemistry of vocs and nox, Atmos. Environ., 34, 2063–2101,  <ext-link xlink:href="https://doi.org/10.1016/S1352-2310(99)00460-4" ext-link-type="DOI">10.1016/S1352-2310(99)00460-4</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><?label 4?><mixed-citation>Atkinson, R. and Arey, J.: Atmospheric degradation of volatile organic compounds, Chem. Rev., 103, 4605–4638,  <ext-link xlink:href="https://doi.org/10.1021/cr0206420" ext-link-type="DOI">10.1021/cr0206420</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><?label 5?><mixed-citation>Bertram, T. H., Kimmel, J. R., Crisp, T. A., Ryder, O. S., Yatavelli, R. L. N., Thornton, J. A., Cubison, M. J., Gonin, M., and Worsnop, D. R.: A field-deployable, chemical ionization time-of-flight mass spectrometer, Atmos. Meas. Tech., 4, 1471–1479,  <ext-link xlink:href="https://doi.org/10.5194/amt-4-1471-2011" ext-link-type="DOI">10.5194/amt-4-1471-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><?label 6?><mixed-citation>Bi, C., Krechmer, J. E., Canagaratna, M. R., and Isaacman-VanWertz, G.: Correcting bias in log-linear instrument calibrations in the context of chemical ionization mass spectrometry, Atmos. Meas. Tech., 14, 6551–6560, <ext-link xlink:href="https://doi.org/10.5194/amt-14-6551-2021" ext-link-type="DOI">10.5194/amt-14-6551-2021</ext-link>, 2021a.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><?label 7?><mixed-citation>Bi, C., Krechmer, J. E., Frazier, G. O., Xu, W., Lambe, A. T., Claflin, M. S., Lerner, B. M., Jayne, J. T., Worsnop, D. R., Canagaratna, M. R., and Isaacman-VanWertz, G.: Coupling a gas chromatograph simultaneously to a flame ionization detector and chemical ionization mass spectrometer for isomer-resolved measurements of particle-phase organic compounds, Atmos. Meas. Tech., 14, 3895–3907,  <ext-link xlink:href="https://doi.org/10.5194/amt-14-3895-2021" ext-link-type="DOI">10.5194/amt-14-3895-2021</ext-link>, 2021b.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><?label 8?><mixed-citation>
Brophy, P.: Development, characterization, and deployment of a high-
resolution time-of-flight chemical ionization mass spectrometer (hr-tof-cims)
for the detection of carboxylic acids and trace-gas species in the
troposphere, PhD, Colorado State University, Fort Collins, Colorado, USA, 2016.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><?label 9?><mixed-citation>Brophy, P. and Farmer, D. K.: Clustering, methodology, and mechanistic insights into acetate chemical ionization using high-resolution time-of-flight mass spectrometry, Atmos. Meas. Tech., 9, 3969–3986,  <ext-link xlink:href="https://doi.org/10.5194/amt-9-3969-2016" ext-link-type="DOI">10.5194/amt-9-3969-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><?label 10?><mixed-citation>Burnett, R. T., Pope, C. A., Ezzati, M., Olives, C., Lim, S. S., Mehta, S., Shin, H. H., Singh, G., Hubbell, B., Brauer, M<?pagebreak page6848?>., Anderson, H. R., Smith, K. R., Balmes, J. R., Bruce, N. G., Kan, H., Laden, F., Prüss-Ustün, A., Turner, M. C., Gapstur, S. M., Diver, W. R., and Cohen, A.: An integrated risk function for estimating the global burden of disease attributable to ambient fine particulate matter exposure, Environ. Health Persp., 122, 397–403,  <ext-link xlink:href="https://doi.org/10.1289/ehp.1307049" ext-link-type="DOI">10.1289/ehp.1307049</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><?label 11?><mixed-citation>Crounse, J. D., McKinney, K. A., Kwan, A. J., and Wennberg, P. O.: Measurement of gas-phase hydroperoxides by chemical ionization mass spectrometry, Anal. Chem., 78, 6726–6732,  <ext-link xlink:href="https://doi.org/10.1021/ac0604235" ext-link-type="DOI">10.1021/ac0604235</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><?label 12?><mixed-citation>Ditto, J. C., Barnes, E. B., Khare, P., Takeuchi, M., Joo, T., Bui, A. A. T., Lee-Taylor, J., Eris, G., Chen, Y., Aumont, B., Jimenez, J. L., Ng, N. L., Griffin, R. J., and Gentner, D. R.: An omnipresent diversity and variability in the chemical composition of atmospheric functionalized organic aerosol, Commun. Chem., 1, 1–13, <ext-link xlink:href="https://doi.org/10.1038/s42004-018-0074-3" ext-link-type="DOI">10.1038/s42004-018-0074-3</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><?label 13?><mixed-citation>Goldan, P. D., Kuster, W. C., Williams, E., Murphy, P. C., Fehsenfeld, F. C., and Meagher, J.: Nonmethane hydrocarbon and oxy hydrocarbon measurements during the 2002 new england air quality study, J. Geophys. Res.-Atmos., 109, 1–14,  <ext-link xlink:href="https://doi.org/10.1029/2003JD004455" ext-link-type="DOI">10.1029/2003JD004455</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><?label 14?><mixed-citation>Goldstein, A. H. and Galbally, I. E.: Known and unexplored organic constituents in the earth's atmosphere, Environ. Sci. Technol., 41, 1514–1521,  <ext-link xlink:href="https://doi.org/10.1021/es072476p" ext-link-type="DOI">10.1021/es072476p</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><?label 15?><mixed-citation>Goldstein, A. H., Daube, B. C., Munger, J. W., and Wofsy, S. C.: Automated in-situ monitoring of atmospheric non-methane hydrocarbon concentrations and gradients, J. Atmos. Chem., 21, 43–59,  <ext-link xlink:href="https://doi.org/10.1007/BF00712437" ext-link-type="DOI">10.1007/BF00712437</ext-link>, 1995.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><?label 16?><mixed-citation>
Grob, R. L. and Barry, E. F.: Modern practice of gas chromatography, 4th
edition, John Wiley and Sons, Inc., Hoboken, New Jersey, USA, 2004.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><?label 17?><mixed-citation>Hallquist, M., Wenger, J. C., Baltensperger, U., Rudich, Y., Simpson, D., Claeys, M., Dommen, J., Donahue, N. M., George, C., Goldstein, A. H., Hamilton, J. F., Herrmann, H., Hoffmann, T., Iinuma, Y., Jang, M., Jenkin, M. E., Jimenez, J. L., Kiendler-Scharr, A., Maenhaut, W., McFiggans, G., Mentel, Th. F., Monod, A., Prévôt, A. S. H., Seinfeld, J. H., Surratt, J. D., Szmigielski, R., and Wildt, J.: The formation, properties and impact of secondary organic aerosol: current and emerging issues, Atmos. Chem. Phys., 9, 5155–5236,  <ext-link xlink:href="https://doi.org/10.5194/acp-9-5155-2009" ext-link-type="DOI">10.5194/acp-9-5155-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><?label 18?><mixed-citation>Helmig, D., Ortega, J., Duhl, T., Tanner, D., Guenther, A., Harley, P., Wiedinmyer, C., Milford, J., and Sakulyanontvittaya, T.: Sesquiterpene emissions from pine trees  –  identifications, emission rates and flux estimates for the contiguous united states, Environ. Sci. Technol., 41, 1545–1553,  <ext-link xlink:href="https://doi.org/10.1021/es0618907" ext-link-type="DOI">10.1021/es0618907</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><?label 19?><mixed-citation>Holm, T.: Aspects of the mechanism of the flame ionization detector, J. Chromatogr. A, 842, 221–227,  <ext-link xlink:href="https://doi.org/10.1016/S0021-9673(98)00706-7" ext-link-type="DOI">10.1016/S0021-9673(98)00706-7</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><?label 20?><mixed-citation>Huey, L. G., Hanson, D. R., and Howard, C. J.: Reactions of sf6- and i- with atmospheric trace gases, J. Phys. Chem., 99, 5001–5008,  <ext-link xlink:href="https://doi.org/10.1021/j100014a021" ext-link-type="DOI">10.1021/j100014a021</ext-link>, 1995.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><?label 21?><mixed-citation>Hurley, J. F., Kreisberg, N. M., Stump, B., Bi, C., Kumar, P., Hering, S. V., Keady, P., and Isaacman-VanWertz, G.: A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures, Atmos. Meas. Tech., 13, 4911–4925,  <ext-link xlink:href="https://doi.org/10.5194/amt-13-4911-2020" ext-link-type="DOI">10.5194/amt-13-4911-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><?label 22?><mixed-citation>Isaacman-Vanwertz, G., Massoli, P., O'Brien, R., Lim, C., Franklin, J. P., Moss, J. A., Hunter, J. F., Nowak, J. B., Canagaratna, M. R., Misztal, P. K., Arata, C., Roscioli, J. R., Herndon, S. T., Onasch, T. B., Lambe, A. T., Jayne, J. T., Su, L., Knopf, D. A., Goldstein, A. H., Worsnop, D. R., and Kroll, J. H.: Chemical evolution of atmospheric organic carbon over multiple generations of oxidation, Nat. Chem., 10, 462–468,  <ext-link xlink:href="https://doi.org/10.1038/s41557-018-0002-2" ext-link-type="DOI">10.1038/s41557-018-0002-2</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><?label 23?><mixed-citation>Isaacman-VanWertz, G., Yee, L. D., Kreisberg, N. M., Wernis, R., Moss, J. A., Hering, S. V., De Sá, S. S., Martin, S. T., Alexander, M. L., Palm, B. B., Hu, W., Campuzano-Jost, P., Day, D. A., Jimenez, J. L., Riva, M., Surratt, J. D., Viegas, J., Manzi, A., Edgerton, E., Baumann, K., Souza, R., Artaxo, P., and Goldstein, A. H.: Ambient gas-particle partitioning of tracers for biogenic oxidation, Environ. Sci. Technol., 50, 9952–9962,  <ext-link xlink:href="https://doi.org/10.1021/acs.est.6b01674" ext-link-type="DOI">10.1021/acs.est.6b01674</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><?label 24?><mixed-citation>Isaacman-VanWertz, G., Sueper, D. T., Aikin, K. C., Lerner, B. M., Gilman, J. B., de Gouw, J. A., Worsnop, D. R., and Goldstein, A. H.: Automated single-ion peak fitting as an efficient approach for analyzing complex chromatographic data, J. Chromatogr. A, 1529, 81–92,  <ext-link xlink:href="https://doi.org/10.1016/j.chroma.2017.11.005" ext-link-type="DOI">10.1016/j.chroma.2017.11.005</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><?label 25?><mixed-citation>Isaacman, G., Kreisberg, N. M., Worton, D. R., Hering, S. V., and Goldstein, A. H.: A versatile and reproducible automatic injection system for liquid standard introduction: application to in-situ calibration, Atmos. Meas. Tech., 4, 1937–1942,  <ext-link xlink:href="https://doi.org/10.5194/amt-4-1937-2011" ext-link-type="DOI">10.5194/amt-4-1937-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><?label 26?><mixed-citation>Isaacman, G., Kreisberg, N. M., Yee, L. D., Worton, D. R., Chan, A. W. H., Moss, J. A., Hering, S. V., and Goldstein, A. H.: Online derivatization for hourly measurements of gas- and particle-phase semi-volatile oxygenated organic compounds by thermal desorption aerosol gas chromatography (SV-TAG), Atmos. Meas. Tech., 7, 4417–4429,  <ext-link xlink:href="https://doi.org/10.5194/amt-7-4417-2014" ext-link-type="DOI">10.5194/amt-7-4417-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><?label 27?><mixed-citation>Iyer, S., Lopez-Hilfiker, F., Lee, B. H., Thornton, J. A., and Kurtén, T.: Modeling the detection of organic and inorganic compounds using iodide-based chemical ionization, J. Phys. Chem. A, 120, 576–587,  <ext-link xlink:href="https://doi.org/10.1021/acs.jpca.5b09837" ext-link-type="DOI">10.1021/acs.jpca.5b09837</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><?label 28?><mixed-citation>Jimenez, J. L., Canagaratna, M. R., Donahue, N. M., Prevot, A. S. H., Zhang, Q., Kroll, J. H., DeCarlo, P. F., Allan, J. D., Coe, H., Ng, N. L., Aiken, A. C., Docherty, K. S., Ulbrich, I. M., Grieshop, A. P., Robinson, A. L., Duplissy, J., Smith, J. D., Wilson, K. R., Lanz, V. A., Hueglin, C., Sun, Y. L., Tian, J., Laaksonen, A., Raatikainen, T., Rautiainen, J., Vaattovaara, P., Ehn, M., Kulmala, M., Tomlinson, J. M., Collins, D. R., Cubison, M. J., Dunlea, E. J., Huffman, J. A., Onasch, T. B., Alfarra, M. R., Williams, P. I., Bower, K., Kondo, Y., Schneider, J., Drewnick, F., Borrmann, S., Weimer, S., Demerjian, K., Salcedo, D., Cottrell, L., Griffin, R., Takami, A., Miyoshi, T., Hatakeyama, S., Shimono, A., Sun, J. Y., Zhang, Y. M., Dzepina, K., Kimmel, J. R., Sueper, D., Jayne, J. T., Herndon, S. C., Trimborn, A. M., Williams, L. R., Wood, E. C., Middlebrook, A. M., Kolb, C. E., Baltensperger, U., and Worsnop, D. R.: Evolution of organic aerosols in the atmosphere, Science, 326, 1525–1529,  <ext-link xlink:href="https://doi.org/10.1126/science.1180353" ext-link-type="DOI">10.1126/science.1180353</ext-link>, 2009.</mixed-citation></ref>
      <?pagebreak page6849?><ref id="bib1.bib29"><label>29</label><?label 29?><mixed-citation>Jokinen, T., Sipilä, M., Junninen, H., Ehn, M., Lönn, G., Hakala, J., Petäjä, T., Mauldin III, R. L., Kulmala, M., and Worsnop, D. R.: Atmospheric sulphuric acid and neutral cluster measurements using CI-APi-TOF, Atmos. Chem. Phys., 12, 4117–4125,  <ext-link xlink:href="https://doi.org/10.5194/acp-12-4117-2012" ext-link-type="DOI">10.5194/acp-12-4117-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><?label 30?><mixed-citation>Kercher, J. P., Riedel, T. P., and Thornton, J. A.: Chlorine activation by N<inline-formula><mml:math id="M222" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M223" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:math></inline-formula>: simultaneous, in situ detection of ClNO<inline-formula><mml:math id="M224" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and N<inline-formula><mml:math id="M225" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M226" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">5</mml:mn></mml:msub></mml:math></inline-formula> by chemical ionization mass spectrometry, Atmos. Meas. Tech., 2, 193–204,  <ext-link xlink:href="https://doi.org/10.5194/amt-2-193-2009" ext-link-type="DOI">10.5194/amt-2-193-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><?label 31?><mixed-citation>Kim, M. J., Zoerb, M. C., Campbell, N. R., Zimmermann, K. J., Blomquist, B. W., Huebert, B. J., and Bertram, T. H.: Revisiting benzene cluster cations for the chemical ionization of dimethyl sulfide and select volatile organic compounds, Atmos. Meas. Tech., 9, 1473–1484,  <ext-link xlink:href="https://doi.org/10.5194/amt-9-1473-2016" ext-link-type="DOI">10.5194/amt-9-1473-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><?label 32?><mixed-citation>Kolb, B., Auer, M., and Pospisil, P.: Ionization detector for gas chromatography with switchable selectivity for carbon, nitrogen and phosphorus, J. Chromatogr. A, 134, 65–71,  <ext-link xlink:href="https://doi.org/10.1016/S0021-9673(00)82570-4" ext-link-type="DOI">10.1016/S0021-9673(00)82570-4</ext-link>, 1977.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><?label 33?><mixed-citation>Koss, A. R., Warneke, C., Yuan, B., Coggon, M. M., Veres, P. R., and de Gouw, J. A.: Evaluation of NO<inline-formula><mml:math id="M227" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> reagent ion chemistry for online measurements of atmospheric volatile organic compounds, Atmos. Meas. Tech., 9, 2909–2925,  <ext-link xlink:href="https://doi.org/10.5194/amt-9-2909-2016" ext-link-type="DOI">10.5194/amt-9-2909-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><?label 34?><mixed-citation>Krechmer, J. E., Coggon, M. M., Massoli, P., Nguyen, T. B., Crounse, J. D., Hu, W., Day, D. A., Tyndall, G. S., Henze, D. K., Rivera-Rios, J. C., Nowak, J. B., Kimmel, J. R., Mauldin, R. L., Stark, H., Jayne, J. T., Sipilä, M., Junninen, H., St. Clair, J. M., Zhang, X., Feiner, P. A., Zhang, L., Miller, D. O., Brune, W. H., Keutsch, F. N., Wennberg, P. O., Seinfeld, J. H., Worsnop, D. R., Jimenez, J. L., and Canagaratna, M. R.: Formation of low volatility organic compounds and secondary organic aerosol from isoprene hydroxyhydroperoxide low-no oxidation, Environ. Sci. Technol., 49, 10330–10339,  <ext-link xlink:href="https://doi.org/10.1021/acs.est.5b02031" ext-link-type="DOI">10.1021/acs.est.5b02031</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><?label 35?><mixed-citation>Kroll, J. H. and Seinfeld, J. H.: Chemistry of secondary organic aerosol: formation and evolution of low-volatility organics in the atmosphere, Atmos. Environ., 42, 3593–3624,  <ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2008.01.003" ext-link-type="DOI">10.1016/j.atmosenv.2008.01.003</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><?label 36?><mixed-citation>Lambe, A. T., Onasch, T. B., Massoli, P., Croasdale, D. R., Wright, J. P., Ahern, A. T., Williams, L. R., Worsnop, D. R., Brune, W. H., and Davidovits, P.: Laboratory studies of the chemical composition and cloud condensation nuclei (CCN) activity of secondary organic aerosol (SOA) and oxidized primary organic aerosol (OPOA), Atmos. Chem. Phys., 11, 8913–8928,  <ext-link xlink:href="https://doi.org/10.5194/acp-11-8913-2011" ext-link-type="DOI">10.5194/acp-11-8913-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><?label 37?><mixed-citation>Lee, B. H., Lopez-Hilfiker, F. D., Mohr, C., Kurtén, T., Worsnop, D. R., and Thornton, J. A.: An iodide-adduct high-resolution time-of-flight chemical-ionization mass spectrometer: application to atmospheric inorganic and organic compounds, Environ. Sci. Technol., 48, 6309–6317,  <ext-link xlink:href="https://doi.org/10.1021/es500362a" ext-link-type="DOI">10.1021/es500362a</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><?label 38?><mixed-citation>Lim, Y. B. and Ziemann, P. J.: Effects of molecular structure on aerosol yields from oh radical-initiated reactions of linear, branched, and cyclic alkanes in the presence of NO<inline-formula><mml:math id="M228" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>, Environ. Sci. Technol., 43, 2328–2334,  <ext-link xlink:href="https://doi.org/10.1021/es803389s" ext-link-type="DOI">10.1021/es803389s</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><?label 39?><mixed-citation>Lopez-Hilfiker, F. D., Iyer, S., Mohr, C., Lee, B. H., D'Ambro, E. L., Kurtén, T., and Thornton, J. A.: Constraining the sensitivity of iodide adduct chemical ionization mass spectrometry to multifunctional organic molecules using the collision limit and thermodynamic stability of iodide ion adducts, Atmos. Meas. Tech., 9, 1505–1512,  <ext-link xlink:href="https://doi.org/10.5194/amt-9-1505-2016" ext-link-type="DOI">10.5194/amt-9-1505-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><?label 40?><mixed-citation>Mattila, J. M., Lakey, P. S. J., Shiraiwa, M., Wang, C., Abbatt, J. P. D., Arata, C., Goldstein, A. H., Ampollini, L., Katz, E. F., Decarlo, P. F., Zhou, S., Kahan, T. F., Cardoso-Saldaña, F. J., Ruiz, L. H., Abeleira, A., Boedicker, E. K., Vance, M. E., and Farmer, D. K.: Multiphase chemistry controls inorganic chlorinated and nitrogenated compounds in indoor air during bleach cleaning, Environ. Sci. Technol., 54, 1730–1739,  <ext-link xlink:href="https://doi.org/10.1021/acs.est.9b05767" ext-link-type="DOI">10.1021/acs.est.9b05767</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><?label 41?><mixed-citation>Millet, D. B.: Atmospheric volatile organic compound measurements during the pittsburgh air quality study: results, interpretation, and quantification of primary and secondary contributions, J. Geophys. Res., 110, D07S07,  <ext-link xlink:href="https://doi.org/10.1029/2004JD004601" ext-link-type="DOI">10.1029/2004JD004601</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><?label 42?><mixed-citation>Nozière, B., Kalberer, M., Claeys, M., Allan, J., D'Anna, B., Decesari, S., Finessi, E., Glasius, M., Grgić, I., Hamilton, J. F., Hoffmann, T., Iinuma, Y., Jaoui, M., Kahnt, A., Kampf, C. J., Kourtchev, I., Maenhaut, W., Marsden, N., Saarikoski, S., Schnelle-Kreis, J., Surratt, J. D., Szidat, S., Szmigielski, R., and Wisthaler, A.: The molecular identification of organic compounds in the atmosphere: state of the art and challenges, Chem. Rev., 115, 3919–3983,  <ext-link xlink:href="https://doi.org/10.1021/cr5003485" ext-link-type="DOI">10.1021/cr5003485</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><?label 43?><mixed-citation>
Onuska, F. I. and Karasek, F. W.: The retention index system, in Open Tubular Column Gas Chromatography in Environmental Sciences, Springer US, Boston, MA., 153–159, 1984.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><?label 44?><mixed-citation>Pagonis, D., Price, D. J., Algrim, L. B., Day, D. A., Handschy, A. V., Stark, H., Miller, S. L., De Gouw, J., Jimenez, J. L., and Ziemann, P. J.: Time-resolved measurements of indoor chemical emissions, deposition, and reactions in a university art museum, Environ. Sci. Technol., 53, 4794–4802,  <ext-link xlink:href="https://doi.org/10.1021/acs.est.9b00276" ext-link-type="DOI">10.1021/acs.est.9b00276</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><?label 45?><mixed-citation>Pope, C. A. and Dockery, D. W.: Health effects of fine particulate air pollution: lines that connect, J. Air Waste Manage., 56, 709–742,  <ext-link xlink:href="https://doi.org/10.1080/10473289.2006.10464485" ext-link-type="DOI">10.1080/10473289.2006.10464485</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><?label 46?><mixed-citation>
Prinn, R. G., Weiss, R. F., Simmonds, P. J. F. P. G., Cunnold, D. M., Alyea, F. N., Doherty, S. O., Salameh, P., Miller, B. R., Huang, J., Wang, R. H. J., Hartley, D. E., Harth, C., Steele, L. P., Sturrock, G., Midgley, P. M., and Mcculloch, A.: A history of chemically and radiatively important gases in air deduced from ale/gage/agage, J. Geophys. Res., 105, 17751–17792, 2000.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><?label 47?><mixed-citation>Riva, M., Heikkinen, L., Bell, D. M., Peräkylä, O., Zha, Q., Schallhart, S., Rissanen, M. P., Imre, D., Petäjä, T., Thornton, J. A., Zelenyuk, A., and Ehn, M.: Chemical transformations in monoterpene-derived organic aerosol enhanced by inorganic composition, npj Clim. Atmos. Sci., 2, 1–9,  <ext-link xlink:href="https://doi.org/10.1038/s41612-018-0058-0" ext-link-type="DOI">10.1038/s41612-018-0058-0</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib48"><label>48</label><?label 48?><mixed-citation>Rowe, J. P., Lambe, A. T., and Brune, W. H.: Technical Note: Effect of varying the <inline-formula><mml:math id="M229" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">185</mml:mn></mml:mrow></mml:math></inline-formula> and 254 <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> photon flux ratio on radical generation in oxidation flow reactors, Atmos. Chem. Phys., 20, 13417–13424,  <ext-link xlink:href="https://doi.org/10.5194/acp-20-13417-2020" ext-link-type="DOI">10.5194/acp-20-13417-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><?label 49?><mixed-citation>Shrivastava, M., Cappa, C. D., Fan, J., Goldstein, A. H., Guenther, A. B., Jimenez, J. L., Kuang, C., Laskin, A., Martin, S. T., Ng, N. L., Petaja, T., Pierce, J. R., Rasch, P. J., Roldin, P., Seinfeld, J. H., Shilling, J., Smith, J. N., Thornton, J. A., Volkamer, R., Wang, J., Worsnop, D. R., Zaveri, R. A., Zelenyuk, A<?pagebreak page6850?>., and Zhang, Q.: Recent advances in understanding secondary organic aerosol: implications for global climate forcing, Rev. Geophys., 55, 509–559,  <ext-link xlink:href="https://doi.org/10.1002/2016RG000540" ext-link-type="DOI">10.1002/2016RG000540</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib50"><label>50</label><?label 50?><mixed-citation>Slusher, D. L., Huey, L. G., Tanner, D. J., Flocke, F. M., and Roberts, J. M.: A thermal dissociation  –  chemical ionization mass spectrometry (td-cims) technique for the simultaneous measurement of peroxyacyl nitrates and dinitrogen pentoxide, J. Geophys. Res.-Atmos., 109, 1–13,  <ext-link xlink:href="https://doi.org/10.1029/2004JD004670" ext-link-type="DOI">10.1029/2004JD004670</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><?label 51?><mixed-citation>Stanaway, J. D., Afshin, A., Gakidou, E., et al.: Global, regional, and national comparative risk assessment of 84 behavioural, environmental and occupational, and metabolic risks or clusters of risks for 195 countries and territories, 1990–2017: a systematic analysis for the global burden of disease stu, Lancet, 392, 1923–1994,  <ext-link xlink:href="https://doi.org/10.1016/S0140-6736(18)32225-6" ext-link-type="DOI">10.1016/S0140-6736(18)32225-6</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib52"><label>52</label><?label 52?><mixed-citation>Thompson, S. L., Yatavelli, R. L. N., Stark, H., Kimmel, J. R., Krechmer, J. E., Day, D. A., Hu, W., Isaacman-VanWertz, G., Yee, L., Goldstein, A. H., Khan, M. A. H., Holzinger, R., Kreisberg, N., Lopez-Hilfiker, F. D., Mohr, C., Thornton, J. A., Jayne, J. T., Canagaratna, M., Worsnop, D. R., and Jimenez, J. L.: Field intercomparison of the gas/particle partitioning of oxygenated organics during the southern oxidant and aerosol study (soas) in 2013, Aerosol Sci. Tech., 51, 30–56,  <ext-link xlink:href="https://doi.org/10.1080/02786826.2016.1254719" ext-link-type="DOI">10.1080/02786826.2016.1254719</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib53"><label>53</label><?label 53?><mixed-citation>Vasquez, K. T., Allen, H. M., Crounse, J. D., Praske, E., Xu, L., Noelscher, A. C., and Wennberg, P. O.: Low-pressure gas chromatography with chemical ionization mass spectrometry for quantification of multifunctional organic compounds in the atmosphere, Atmos. Meas. Tech., 11, 6815–6832,  <ext-link xlink:href="https://doi.org/10.5194/amt-11-6815-2018" ext-link-type="DOI">10.5194/amt-11-6815-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><?label 54?><mixed-citation>Williams, B., Goldstein, A., Kreisberg, N., and Hering, S.: An in-situ instrument for speciated organic composition of atmospheric aerosols: thermal desorption aerosol gc/ms-fid (tag), Aerosol Sci. Tech., 40, 627–638,  <ext-link xlink:href="https://doi.org/10.1080/02786820600754631" ext-link-type="DOI">10.1080/02786820600754631</ext-link>, 2006.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib55"><label>55</label><?label 55?><mixed-citation>Yuan, B., Koss, A., Warneke, C., Gilman, J. B., Lerner, B. M., Stark, H., and de Gouw, J. A.: A high-resolution time-of-flight chemical ionization mass spectrometer utilizing hydronium ions (<inline-formula><mml:math id="M231" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> ToF-CIMS) for measurements of volatile organic compounds in the atmosphere, Atmos. Meas. Tech., 9, 2735–2752,  <ext-link xlink:href="https://doi.org/10.5194/amt-9-2735-2016" ext-link-type="DOI">10.5194/amt-9-2735-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><?label 56?><mixed-citation>Zaytsev, A., Breitenlechner, M., Koss, A. R., Lim, C. Y., Rowe, J. C., Kroll, J. H., and Keutsch, F. N.: Using collision-induced dissociation to constrain sensitivity of ammonia chemical ionization mass spectrometry (<inline-formula><mml:math id="M232" display="inline"><mml:mrow class="chem"><mml:msubsup><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> CIMS) to oxygenated volatile organic compounds, Atmos. Meas. Tech., 12, 1861–1870,  <ext-link xlink:href="https://doi.org/10.5194/amt-12-1861-2019" ext-link-type="DOI">10.5194/amt-12-1861-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><?label 57?><mixed-citation>Zhang, H., Yee, L. D., Lee, B. H., Curtis, M. P., Worton, D. R., Isaacman-VanWertz, G., Offenberg, J. H., Lewandowski, M., Kleindienst, T. E., Beaver, M. R., Holder, A. L., Lonneman, W. A., Docherty, K. S., Jaoui, M., Pye, H. O. T., Hu, W., Day, D. A., Campuzano-Jost, P., Jimenez, J. L., Guo, H., Weber, R. J., De Gouw, J., Koss, A. R., Edgerton, E. S., Brune, W., Mohr, C., Lopez-Hilfiker, F. D., Lutz, A., Kreisberg, N. M., Spielman, S. R., Hering, S. V., Wilson, K. R., Thornton, J. A., and Goldstein, A. H.: Monoterpenes are the largest source of summertime organic aerosol in the southeastern united states, P. Natl. Acad. Sci. USA, 115, 2038–2043,  <ext-link xlink:href="https://doi.org/10.1073/pnas.1717513115" ext-link-type="DOI">10.1073/pnas.1717513115</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib58"><label>58</label><?label 58?><mixed-citation>Zhao, Y., Kreisberg, N. M., Worton, D. R., Teng, A. P., Hering, S. V., and Goldstein, A. H.: Development of an in situ thermal desorption gas chromatography instrument for quantifying atmospheric semi-volatile organic compounds, Aerosol Sci. Tech., 47, 258–266,  <ext-link xlink:href="https://doi.org/10.1080/02786826.2012.747673" ext-link-type="DOI">10.1080/02786826.2012.747673</ext-link>, 2013.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Quantification of isomer-resolved iodide chemical ionization mass spectrometry sensitivity and uncertainty using a voltage-scanning approach</article-title-html>
<abstract-html><p>Chemical ionization mass spectrometry (CIMS) using iodide as a reagent ion has been widely used to classify organic compounds in the atmosphere by their
elemental formula. Unfortunately, calibration of these instruments is
challenging due to a lack of commercially available standards for many
compounds, which has led to the development of methods for estimating CIMS
sensitivity. By coupling a thermal desorption aerosol gas chromatograph (TAG) simultaneously to a flame ionization detector (FID) and an iodide CIMS, we use
the individual particle-phase analytes, quantified by the FID, to examine the
sensitivity of the CIMS and its variability between isomers of the same
elemental formula. Iodide CIMS sensitivities of isomers within a formula are
found to generally vary by 1 order of magnitude with a maximum deviation of 2 orders of magnitude. Furthermore, we compare directly measured sensitivity
to a method of estimating sensitivity based on declustering voltage (i.e.,
<q>voltage scanning</q>). This approach is found to carry high uncertainties for
individual analytes (0.5 to 1 order of magnitude) but represents a central tendency that can be used to estimate the sum of analytes with reasonable
error ( ∼ 30&thinsp;% differences between predicted and measured
moles). Finally, gas chromatography (GC) retention time, which is associated with vapor pressure and chemical functionality of an analyte, is found to qualitatively correlate
with iodide CIMS sensitivity, but the relationship is not close enough to be
quantitatively useful and could be explored further in the future as a
potential calibration approach.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Aljawhary, D., Lee, A. K. Y., and Abbatt, J. P. D.: High-resolution chemical ionization mass spectrometry (ToF-CIMS): application to study SOA composition and processing, Atmos. Meas. Tech., 6, 3211–3224,  <a href="https://doi.org/10.5194/amt-6-3211-2013" target="_blank">https://doi.org/10.5194/amt-6-3211-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Arangio, A. M., Tong, H., Socorro, J., Pöschl, U., and Shiraiwa, M.: Quantification of environmentally persistent free radicals and reactive oxygen species in atmospheric aerosol particles, Atmos. Chem. Phys., 16, 13105–13119,  <a href="https://doi.org/10.5194/acp-16-13105-2016" target="_blank">https://doi.org/10.5194/acp-16-13105-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Atkinson, R.: Atmospheric chemistry of vocs and nox, Atmos. Environ., 34, 2063–2101,  <a href="https://doi.org/10.1016/S1352-2310(99)00460-4" target="_blank">https://doi.org/10.1016/S1352-2310(99)00460-4</a>, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Atkinson, R. and Arey, J.: Atmospheric degradation of volatile organic compounds, Chem. Rev., 103, 4605–4638,  <a href="https://doi.org/10.1021/cr0206420" target="_blank">https://doi.org/10.1021/cr0206420</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Bertram, T. H., Kimmel, J. R., Crisp, T. A., Ryder, O. S., Yatavelli, R. L. N., Thornton, J. A., Cubison, M. J., Gonin, M., and Worsnop, D. R.: A field-deployable, chemical ionization time-of-flight mass spectrometer, Atmos. Meas. Tech., 4, 1471–1479,  <a href="https://doi.org/10.5194/amt-4-1471-2011" target="_blank">https://doi.org/10.5194/amt-4-1471-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Bi, C., Krechmer, J. E., Canagaratna, M. R., and Isaacman-VanWertz, G.: Correcting bias in log-linear instrument calibrations in the context of chemical ionization mass spectrometry, Atmos. Meas. Tech., 14, 6551–6560, <a href="https://doi.org/10.5194/amt-14-6551-2021" target="_blank">https://doi.org/10.5194/amt-14-6551-2021</a>, 2021a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Bi, C., Krechmer, J. E., Frazier, G. O., Xu, W., Lambe, A. T., Claflin, M. S., Lerner, B. M., Jayne, J. T., Worsnop, D. R., Canagaratna, M. R., and Isaacman-VanWertz, G.: Coupling a gas chromatograph simultaneously to a flame ionization detector and chemical ionization mass spectrometer for isomer-resolved measurements of particle-phase organic compounds, Atmos. Meas. Tech., 14, 3895–3907,  <a href="https://doi.org/10.5194/amt-14-3895-2021" target="_blank">https://doi.org/10.5194/amt-14-3895-2021</a>, 2021b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Brophy, P.: Development, characterization, and deployment of a high-
resolution time-of-flight chemical ionization mass spectrometer (hr-tof-cims)
for the detection of carboxylic acids and trace-gas species in the
troposphere, PhD, Colorado State University, Fort Collins, Colorado, USA, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Brophy, P. and Farmer, D. K.: Clustering, methodology, and mechanistic insights into acetate chemical ionization using high-resolution time-of-flight mass spectrometry, Atmos. Meas. Tech., 9, 3969–3986,  <a href="https://doi.org/10.5194/amt-9-3969-2016" target="_blank">https://doi.org/10.5194/amt-9-3969-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Burnett, R. T., Pope, C. A., Ezzati, M., Olives, C., Lim, S. S., Mehta, S., Shin, H. H., Singh, G., Hubbell, B., Brauer, M., Anderson, H. R., Smith, K. R., Balmes, J. R., Bruce, N. G., Kan, H., Laden, F., Prüss-Ustün, A., Turner, M. C., Gapstur, S. M., Diver, W. R., and Cohen, A.: An integrated risk function for estimating the global burden of disease attributable to ambient fine particulate matter exposure, Environ. Health Persp., 122, 397–403,  <a href="https://doi.org/10.1289/ehp.1307049" target="_blank">https://doi.org/10.1289/ehp.1307049</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Crounse, J. D., McKinney, K. A., Kwan, A. J., and Wennberg, P. O.: Measurement of gas-phase hydroperoxides by chemical ionization mass spectrometry, Anal. Chem., 78, 6726–6732,  <a href="https://doi.org/10.1021/ac0604235" target="_blank">https://doi.org/10.1021/ac0604235</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Ditto, J. C., Barnes, E. B., Khare, P., Takeuchi, M., Joo, T., Bui, A. A. T., Lee-Taylor, J., Eris, G., Chen, Y., Aumont, B., Jimenez, J. L., Ng, N. L., Griffin, R. J., and Gentner, D. R.: An omnipresent diversity and variability in the chemical composition of atmospheric functionalized organic aerosol, Commun. Chem., 1, 1–13, <a href="https://doi.org/10.1038/s42004-018-0074-3" target="_blank">https://doi.org/10.1038/s42004-018-0074-3</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Goldan, P. D., Kuster, W. C., Williams, E., Murphy, P. C., Fehsenfeld, F. C., and Meagher, J.: Nonmethane hydrocarbon and oxy hydrocarbon measurements during the 2002 new england air quality study, J. Geophys. Res.-Atmos., 109, 1–14,  <a href="https://doi.org/10.1029/2003JD004455" target="_blank">https://doi.org/10.1029/2003JD004455</a>, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Goldstein, A. H. and Galbally, I. E.: Known and unexplored organic constituents in the earth's atmosphere, Environ. Sci. Technol., 41, 1514–1521,  <a href="https://doi.org/10.1021/es072476p" target="_blank">https://doi.org/10.1021/es072476p</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Goldstein, A. H., Daube, B. C., Munger, J. W., and Wofsy, S. C.: Automated in-situ monitoring of atmospheric non-methane hydrocarbon concentrations and gradients, J. Atmos. Chem., 21, 43–59,  <a href="https://doi.org/10.1007/BF00712437" target="_blank">https://doi.org/10.1007/BF00712437</a>, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Grob, R. L. and Barry, E. F.: Modern practice of gas chromatography, 4th
edition, John Wiley and Sons, Inc., Hoboken, New Jersey, USA, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Hallquist, M., Wenger, J. C., Baltensperger, U., Rudich, Y., Simpson, D., Claeys, M., Dommen, J., Donahue, N. M., George, C., Goldstein, A. H., Hamilton, J. F., Herrmann, H., Hoffmann, T., Iinuma, Y., Jang, M., Jenkin, M. E., Jimenez, J. L., Kiendler-Scharr, A., Maenhaut, W., McFiggans, G., Mentel, Th. F., Monod, A., Prévôt, A. S. H., Seinfeld, J. H., Surratt, J. D., Szmigielski, R., and Wildt, J.: The formation, properties and impact of secondary organic aerosol: current and emerging issues, Atmos. Chem. Phys., 9, 5155–5236,  <a href="https://doi.org/10.5194/acp-9-5155-2009" target="_blank">https://doi.org/10.5194/acp-9-5155-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Helmig, D., Ortega, J., Duhl, T., Tanner, D., Guenther, A., Harley, P., Wiedinmyer, C., Milford, J., and Sakulyanontvittaya, T.: Sesquiterpene emissions from pine trees  –  identifications, emission rates and flux estimates for the contiguous united states, Environ. Sci. Technol., 41, 1545–1553,  <a href="https://doi.org/10.1021/es0618907" target="_blank">https://doi.org/10.1021/es0618907</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Holm, T.: Aspects of the mechanism of the flame ionization detector, J. Chromatogr. A, 842, 221–227,  <a href="https://doi.org/10.1016/S0021-9673(98)00706-7" target="_blank">https://doi.org/10.1016/S0021-9673(98)00706-7</a>, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Huey, L. G., Hanson, D. R., and Howard, C. J.: Reactions of sf6- and i- with atmospheric trace gases, J. Phys. Chem., 99, 5001–5008,  <a href="https://doi.org/10.1021/j100014a021" target="_blank">https://doi.org/10.1021/j100014a021</a>, 1995.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Hurley, J. F., Kreisberg, N. M., Stump, B., Bi, C., Kumar, P., Hering, S. V., Keady, P., and Isaacman-VanWertz, G.: A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures, Atmos. Meas. Tech., 13, 4911–4925,  <a href="https://doi.org/10.5194/amt-13-4911-2020" target="_blank">https://doi.org/10.5194/amt-13-4911-2020</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Isaacman-Vanwertz, G., Massoli, P., O'Brien, R., Lim, C., Franklin, J. P., Moss, J. A., Hunter, J. F., Nowak, J. B., Canagaratna, M. R., Misztal, P. K., Arata, C., Roscioli, J. R., Herndon, S. T., Onasch, T. B., Lambe, A. T., Jayne, J. T., Su, L., Knopf, D. A., Goldstein, A. H., Worsnop, D. R., and Kroll, J. H.: Chemical evolution of atmospheric organic carbon over multiple generations of oxidation, Nat. Chem., 10, 462–468,  <a href="https://doi.org/10.1038/s41557-018-0002-2" target="_blank">https://doi.org/10.1038/s41557-018-0002-2</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Isaacman-VanWertz, G., Yee, L. D., Kreisberg, N. M., Wernis, R., Moss, J. A., Hering, S. V., De Sá, S. S., Martin, S. T., Alexander, M. L., Palm, B. B., Hu, W., Campuzano-Jost, P., Day, D. A., Jimenez, J. L., Riva, M., Surratt, J. D., Viegas, J., Manzi, A., Edgerton, E., Baumann, K., Souza, R., Artaxo, P., and Goldstein, A. H.: Ambient gas-particle partitioning of tracers for biogenic oxidation, Environ. Sci. Technol., 50, 9952–9962,  <a href="https://doi.org/10.1021/acs.est.6b01674" target="_blank">https://doi.org/10.1021/acs.est.6b01674</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Isaacman-VanWertz, G., Sueper, D. T., Aikin, K. C., Lerner, B. M., Gilman, J. B., de Gouw, J. A., Worsnop, D. R., and Goldstein, A. H.: Automated single-ion peak fitting as an efficient approach for analyzing complex chromatographic data, J. Chromatogr. A, 1529, 81–92,  <a href="https://doi.org/10.1016/j.chroma.2017.11.005" target="_blank">https://doi.org/10.1016/j.chroma.2017.11.005</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Isaacman, G., Kreisberg, N. M., Worton, D. R., Hering, S. V., and Goldstein, A. H.: A versatile and reproducible automatic injection system for liquid standard introduction: application to in-situ calibration, Atmos. Meas. Tech., 4, 1937–1942,  <a href="https://doi.org/10.5194/amt-4-1937-2011" target="_blank">https://doi.org/10.5194/amt-4-1937-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Isaacman, G., Kreisberg, N. M., Yee, L. D., Worton, D. R., Chan, A. W. H., Moss, J. A., Hering, S. V., and Goldstein, A. H.: Online derivatization for hourly measurements of gas- and particle-phase semi-volatile oxygenated organic compounds by thermal desorption aerosol gas chromatography (SV-TAG), Atmos. Meas. Tech., 7, 4417–4429,  <a href="https://doi.org/10.5194/amt-7-4417-2014" target="_blank">https://doi.org/10.5194/amt-7-4417-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Iyer, S., Lopez-Hilfiker, F., Lee, B. H., Thornton, J. A., and Kurtén, T.: Modeling the detection of organic and inorganic compounds using iodide-based chemical ionization, J. Phys. Chem. A, 120, 576–587,  <a href="https://doi.org/10.1021/acs.jpca.5b09837" target="_blank">https://doi.org/10.1021/acs.jpca.5b09837</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Jimenez, J. L., Canagaratna, M. R., Donahue, N. M., Prevot, A. S. H., Zhang, Q., Kroll, J. H., DeCarlo, P. F., Allan, J. D., Coe, H., Ng, N. L., Aiken, A. C., Docherty, K. S., Ulbrich, I. M., Grieshop, A. P., Robinson, A. L., Duplissy, J., Smith, J. D., Wilson, K. R., Lanz, V. A., Hueglin, C., Sun, Y. L., Tian, J., Laaksonen, A., Raatikainen, T., Rautiainen, J., Vaattovaara, P., Ehn, M., Kulmala, M., Tomlinson, J. M., Collins, D. R., Cubison, M. J., Dunlea, E. J., Huffman, J. A., Onasch, T. B., Alfarra, M. R., Williams, P. I., Bower, K., Kondo, Y., Schneider, J., Drewnick, F., Borrmann, S., Weimer, S., Demerjian, K., Salcedo, D., Cottrell, L., Griffin, R., Takami, A., Miyoshi, T., Hatakeyama, S., Shimono, A., Sun, J. Y., Zhang, Y. M., Dzepina, K., Kimmel, J. R., Sueper, D., Jayne, J. T., Herndon, S. C., Trimborn, A. M., Williams, L. R., Wood, E. C., Middlebrook, A. M., Kolb, C. E., Baltensperger, U., and Worsnop, D. R.: Evolution of organic aerosols in the atmosphere, Science, 326, 1525–1529,  <a href="https://doi.org/10.1126/science.1180353" target="_blank">https://doi.org/10.1126/science.1180353</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Jokinen, T., Sipilä, M., Junninen, H., Ehn, M., Lönn, G., Hakala, J., Petäjä, T., Mauldin III, R. L., Kulmala, M., and Worsnop, D. R.: Atmospheric sulphuric acid and neutral cluster measurements using CI-APi-TOF, Atmos. Chem. Phys., 12, 4117–4125,  <a href="https://doi.org/10.5194/acp-12-4117-2012" target="_blank">https://doi.org/10.5194/acp-12-4117-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Kercher, J. P., Riedel, T. P., and Thornton, J. A.: Chlorine activation by N<sub>2</sub>O<sub>5</sub>: simultaneous, in situ detection of ClNO<sub>2</sub> and N<sub>2</sub>O<sub>5</sub> by chemical ionization mass spectrometry, Atmos. Meas. Tech., 2, 193–204,  <a href="https://doi.org/10.5194/amt-2-193-2009" target="_blank">https://doi.org/10.5194/amt-2-193-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Kim, M. J., Zoerb, M. C., Campbell, N. R., Zimmermann, K. J., Blomquist, B. W., Huebert, B. J., and Bertram, T. H.: Revisiting benzene cluster cations for the chemical ionization of dimethyl sulfide and select volatile organic compounds, Atmos. Meas. Tech., 9, 1473–1484,  <a href="https://doi.org/10.5194/amt-9-1473-2016" target="_blank">https://doi.org/10.5194/amt-9-1473-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Kolb, B., Auer, M., and Pospisil, P.: Ionization detector for gas chromatography with switchable selectivity for carbon, nitrogen and phosphorus, J. Chromatogr. A, 134, 65–71,  <a href="https://doi.org/10.1016/S0021-9673(00)82570-4" target="_blank">https://doi.org/10.1016/S0021-9673(00)82570-4</a>, 1977.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Koss, A. R., Warneke, C., Yuan, B., Coggon, M. M., Veres, P. R., and de Gouw, J. A.: Evaluation of NO<sup>+</sup> reagent ion chemistry for online measurements of atmospheric volatile organic compounds, Atmos. Meas. Tech., 9, 2909–2925,  <a href="https://doi.org/10.5194/amt-9-2909-2016" target="_blank">https://doi.org/10.5194/amt-9-2909-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Krechmer, J. E., Coggon, M. M., Massoli, P., Nguyen, T. B., Crounse, J. D., Hu, W., Day, D. A., Tyndall, G. S., Henze, D. K., Rivera-Rios, J. C., Nowak, J. B., Kimmel, J. R., Mauldin, R. L., Stark, H., Jayne, J. T., Sipilä, M., Junninen, H., St. Clair, J. M., Zhang, X., Feiner, P. A., Zhang, L., Miller, D. O., Brune, W. H., Keutsch, F. N., Wennberg, P. O., Seinfeld, J. H., Worsnop, D. R., Jimenez, J. L., and Canagaratna, M. R.: Formation of low volatility organic compounds and secondary organic aerosol from isoprene hydroxyhydroperoxide low-no oxidation, Environ. Sci. Technol., 49, 10330–10339,  <a href="https://doi.org/10.1021/acs.est.5b02031" target="_blank">https://doi.org/10.1021/acs.est.5b02031</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Kroll, J. H. and Seinfeld, J. H.: Chemistry of secondary organic aerosol: formation and evolution of low-volatility organics in the atmosphere, Atmos. Environ., 42, 3593–3624,  <a href="https://doi.org/10.1016/j.atmosenv.2008.01.003" target="_blank">https://doi.org/10.1016/j.atmosenv.2008.01.003</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Lambe, A. T., Onasch, T. B., Massoli, P., Croasdale, D. R., Wright, J. P., Ahern, A. T., Williams, L. R., Worsnop, D. R., Brune, W. H., and Davidovits, P.: Laboratory studies of the chemical composition and cloud condensation nuclei (CCN) activity of secondary organic aerosol (SOA) and oxidized primary organic aerosol (OPOA), Atmos. Chem. Phys., 11, 8913–8928,  <a href="https://doi.org/10.5194/acp-11-8913-2011" target="_blank">https://doi.org/10.5194/acp-11-8913-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Lee, B. H., Lopez-Hilfiker, F. D., Mohr, C., Kurtén, T., Worsnop, D. R., and Thornton, J. A.: An iodide-adduct high-resolution time-of-flight chemical-ionization mass spectrometer: application to atmospheric inorganic and organic compounds, Environ. Sci. Technol., 48, 6309–6317,  <a href="https://doi.org/10.1021/es500362a" target="_blank">https://doi.org/10.1021/es500362a</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Lim, Y. B. and Ziemann, P. J.: Effects of molecular structure on aerosol yields from oh radical-initiated reactions of linear, branched, and cyclic alkanes in the presence of NO<sub><i>x</i></sub>, Environ. Sci. Technol., 43, 2328–2334,  <a href="https://doi.org/10.1021/es803389s" target="_blank">https://doi.org/10.1021/es803389s</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
Lopez-Hilfiker, F. D., Iyer, S., Mohr, C., Lee, B. H., D'Ambro, E. L., Kurtén, T., and Thornton, J. A.: Constraining the sensitivity of iodide adduct chemical ionization mass spectrometry to multifunctional organic molecules using the collision limit and thermodynamic stability of iodide ion adducts, Atmos. Meas. Tech., 9, 1505–1512,  <a href="https://doi.org/10.5194/amt-9-1505-2016" target="_blank">https://doi.org/10.5194/amt-9-1505-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Mattila, J. M., Lakey, P. S. J., Shiraiwa, M., Wang, C., Abbatt, J. P. D., Arata, C., Goldstein, A. H., Ampollini, L., Katz, E. F., Decarlo, P. F., Zhou, S., Kahan, T. F., Cardoso-Saldaña, F. J., Ruiz, L. H., Abeleira, A., Boedicker, E. K., Vance, M. E., and Farmer, D. K.: Multiphase chemistry controls inorganic chlorinated and nitrogenated compounds in indoor air during bleach cleaning, Environ. Sci. Technol., 54, 1730–1739,  <a href="https://doi.org/10.1021/acs.est.9b05767" target="_blank">https://doi.org/10.1021/acs.est.9b05767</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Millet, D. B.: Atmospheric volatile organic compound measurements during the pittsburgh air quality study: results, interpretation, and quantification of primary and secondary contributions, J. Geophys. Res., 110, D07S07,  <a href="https://doi.org/10.1029/2004JD004601" target="_blank">https://doi.org/10.1029/2004JD004601</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Nozière, B., Kalberer, M., Claeys, M., Allan, J., D'Anna, B., Decesari, S., Finessi, E., Glasius, M., Grgić, I., Hamilton, J. F., Hoffmann, T., Iinuma, Y., Jaoui, M., Kahnt, A., Kampf, C. J., Kourtchev, I., Maenhaut, W., Marsden, N., Saarikoski, S., Schnelle-Kreis, J., Surratt, J. D., Szidat, S., Szmigielski, R., and Wisthaler, A.: The molecular identification of organic compounds in the atmosphere: state of the art and challenges, Chem. Rev., 115, 3919–3983,  <a href="https://doi.org/10.1021/cr5003485" target="_blank">https://doi.org/10.1021/cr5003485</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
Onuska, F. I. and Karasek, F. W.: The retention index system, in Open Tubular Column Gas Chromatography in Environmental Sciences, Springer US, Boston, MA., 153–159, 1984.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Pagonis, D., Price, D. J., Algrim, L. B., Day, D. A., Handschy, A. V., Stark, H., Miller, S. L., De Gouw, J., Jimenez, J. L., and Ziemann, P. J.: Time-resolved measurements of indoor chemical emissions, deposition, and reactions in a university art museum, Environ. Sci. Technol., 53, 4794–4802,  <a href="https://doi.org/10.1021/acs.est.9b00276" target="_blank">https://doi.org/10.1021/acs.est.9b00276</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Pope, C. A. and Dockery, D. W.: Health effects of fine particulate air pollution: lines that connect, J. Air Waste Manage., 56, 709–742,  <a href="https://doi.org/10.1080/10473289.2006.10464485" target="_blank">https://doi.org/10.1080/10473289.2006.10464485</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
Prinn, R. G., Weiss, R. F., Simmonds, P. J. F. P. G., Cunnold, D. M., Alyea, F. N., Doherty, S. O., Salameh, P., Miller, B. R., Huang, J., Wang, R. H. J., Hartley, D. E., Harth, C., Steele, L. P., Sturrock, G., Midgley, P. M., and Mcculloch, A.: A history of chemically and radiatively important gases in air deduced from ale/gage/agage, J. Geophys. Res., 105, 17751–17792, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Riva, M., Heikkinen, L., Bell, D. M., Peräkylä, O., Zha, Q., Schallhart, S., Rissanen, M. P., Imre, D., Petäjä, T., Thornton, J. A., Zelenyuk, A., and Ehn, M.: Chemical transformations in monoterpene-derived organic aerosol enhanced by inorganic composition, npj Clim. Atmos. Sci., 2, 1–9,  <a href="https://doi.org/10.1038/s41612-018-0058-0" target="_blank">https://doi.org/10.1038/s41612-018-0058-0</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation>
Rowe, J. P., Lambe, A. T., and Brune, W. H.: Technical Note: Effect of varying the <i>λ</i> = 185 and 254&thinsp;nm photon flux ratio on radical generation in oxidation flow reactors, Atmos. Chem. Phys., 20, 13417–13424,  <a href="https://doi.org/10.5194/acp-20-13417-2020" target="_blank">https://doi.org/10.5194/acp-20-13417-2020</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation>
Shrivastava, M., Cappa, C. D., Fan, J., Goldstein, A. H., Guenther, A. B., Jimenez, J. L., Kuang, C., Laskin, A., Martin, S. T., Ng, N. L., Petaja, T., Pierce, J. R., Rasch, P. J., Roldin, P., Seinfeld, J. H., Shilling, J., Smith, J. N., Thornton, J. A., Volkamer, R., Wang, J., Worsnop, D. R., Zaveri, R. A., Zelenyuk, A., and Zhang, Q.: Recent advances in understanding secondary organic aerosol: implications for global climate forcing, Rev. Geophys., 55, 509–559,  <a href="https://doi.org/10.1002/2016RG000540" target="_blank">https://doi.org/10.1002/2016RG000540</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation>
Slusher, D. L., Huey, L. G., Tanner, D. J., Flocke, F. M., and Roberts, J. M.: A thermal dissociation  –  chemical ionization mass spectrometry (td-cims) technique for the simultaneous measurement of peroxyacyl nitrates and dinitrogen pentoxide, J. Geophys. Res.-Atmos., 109, 1–13,  <a href="https://doi.org/10.1029/2004JD004670" target="_blank">https://doi.org/10.1029/2004JD004670</a>, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation>
Stanaway, J. D., Afshin, A., Gakidou, E., et al.: Global, regional, and national comparative risk assessment of 84 behavioural, environmental and occupational, and metabolic risks or clusters of risks for 195 countries and territories, 1990–2017: a systematic analysis for the global burden of disease stu, Lancet, 392, 1923–1994,  <a href="https://doi.org/10.1016/S0140-6736(18)32225-6" target="_blank">https://doi.org/10.1016/S0140-6736(18)32225-6</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation>
Thompson, S. L., Yatavelli, R. L. N., Stark, H., Kimmel, J. R., Krechmer, J. E., Day, D. A., Hu, W., Isaacman-VanWertz, G., Yee, L., Goldstein, A. H., Khan, M. A. H., Holzinger, R., Kreisberg, N., Lopez-Hilfiker, F. D., Mohr, C., Thornton, J. A., Jayne, J. T., Canagaratna, M., Worsnop, D. R., and Jimenez, J. L.: Field intercomparison of the gas/particle partitioning of oxygenated organics during the southern oxidant and aerosol study (soas) in 2013, Aerosol Sci. Tech., 51, 30–56,  <a href="https://doi.org/10.1080/02786826.2016.1254719" target="_blank">https://doi.org/10.1080/02786826.2016.1254719</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation>
Vasquez, K. T., Allen, H. M., Crounse, J. D., Praske, E., Xu, L., Noelscher, A. C., and Wennberg, P. O.: Low-pressure gas chromatography with chemical ionization mass spectrometry for quantification of multifunctional organic compounds in the atmosphere, Atmos. Meas. Tech., 11, 6815–6832,  <a href="https://doi.org/10.5194/amt-11-6815-2018" target="_blank">https://doi.org/10.5194/amt-11-6815-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation>
Williams, B., Goldstein, A., Kreisberg, N., and Hering, S.: An in-situ instrument for speciated organic composition of atmospheric aerosols: thermal desorption aerosol gc/ms-fid (tag), Aerosol Sci. Tech., 40, 627–638,  <a href="https://doi.org/10.1080/02786820600754631" target="_blank">https://doi.org/10.1080/02786820600754631</a>, 2006.

</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation>
Yuan, B., Koss, A., Warneke, C., Gilman, J. B., Lerner, B. M., Stark, H., and de Gouw, J. A.: A high-resolution time-of-flight chemical ionization mass spectrometer utilizing hydronium ions (H<sub>3</sub>O<sup>+</sup> ToF-CIMS) for measurements of volatile organic compounds in the atmosphere, Atmos. Meas. Tech., 9, 2735–2752,  <a href="https://doi.org/10.5194/amt-9-2735-2016" target="_blank">https://doi.org/10.5194/amt-9-2735-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation>
Zaytsev, A., Breitenlechner, M., Koss, A. R., Lim, C. Y., Rowe, J. C., Kroll, J. H., and Keutsch, F. N.: Using collision-induced dissociation to constrain sensitivity of ammonia chemical ionization mass spectrometry (NH<sub>4</sub><sup>+</sup> CIMS) to oxygenated volatile organic compounds, Atmos. Meas. Tech., 12, 1861–1870,  <a href="https://doi.org/10.5194/amt-12-1861-2019" target="_blank">https://doi.org/10.5194/amt-12-1861-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation>
Zhang, H., Yee, L. D., Lee, B. H., Curtis, M. P., Worton, D. R., Isaacman-VanWertz, G., Offenberg, J. H., Lewandowski, M., Kleindienst, T. E., Beaver, M. R., Holder, A. L., Lonneman, W. A., Docherty, K. S., Jaoui, M., Pye, H. O. T., Hu, W., Day, D. A., Campuzano-Jost, P., Jimenez, J. L., Guo, H., Weber, R. J., De Gouw, J., Koss, A. R., Edgerton, E. S., Brune, W., Mohr, C., Lopez-Hilfiker, F. D., Lutz, A., Kreisberg, N. M., Spielman, S. R., Hering, S. V., Wilson, K. R., Thornton, J. A., and Goldstein, A. H.: Monoterpenes are the largest source of summertime organic aerosol in the southeastern united states, P. Natl. Acad. Sci. USA, 115, 2038–2043,  <a href="https://doi.org/10.1073/pnas.1717513115" target="_blank">https://doi.org/10.1073/pnas.1717513115</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>58</label><mixed-citation>
Zhao, Y., Kreisberg, N. M., Worton, D. R., Teng, A. P., Hering, S. V., and Goldstein, A. H.: Development of an in situ thermal desorption gas chromatography instrument for quantifying atmospheric semi-volatile organic compounds, Aerosol Sci. Tech., 47, 258–266,  <a href="https://doi.org/10.1080/02786826.2012.747673" target="_blank">https://doi.org/10.1080/02786826.2012.747673</a>, 2013.
</mixed-citation></ref-html>--></article>
