<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-14-7693-2021</article-id><title-group><article-title>Assessment of real-time bioaerosol particle counters using reference chamber experiments</article-title><alt-title>Assessment of real-time bioaerosol particle counters</alt-title>
      </title-group><?xmltex \runningtitle{Assessment of real-time bioaerosol particle counters}?><?xmltex \runningauthor{G. Lieberherr  et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Lieberherr</surname><given-names>Gian</given-names></name>
          <email>gian.lieberherr@meteoswiss.ch</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Auderset</surname><given-names>Kevin</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Calpini</surname><given-names>Bertrand</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Clot</surname><given-names>Bernard</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Crouzy</surname><given-names>Benoît</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Gysel-Beer</surname><given-names>Martin</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-7453-1264</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Konzelmann</surname><given-names>Thomas</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4 aff7">
          <name><surname>Manzano</surname><given-names>José</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3595-0949</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Mihajlovic</surname><given-names>Andrea</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Moallemi</surname><given-names>Alireza</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4 aff6">
          <name><surname>O'Connor</surname><given-names>David</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Sikoparija</surname><given-names>Branko</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6766-4149</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff8">
          <name><surname>Sauvageat</surname><given-names>Eric</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Tummon</surname><given-names>Fiona</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6459-339X</ext-link></contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff2">
          <name><surname>Vasilatou</surname><given-names>Konstantina</given-names></name>
          <email>konstantina.vasilatou@metas.ch</email>
        <ext-link>https://orcid.org/0000-0002-7771-9596</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>Federal Office of Meteorology and Climatology MeteoSwiss, Payerne, Switzerland</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Federal Institute of Metrology (METAS), Bern-Wabern, Switzerland</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Laboratory of Atmospheric Chemistry, Paul Scherrer Institute, Villigen, Switzerland</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Technological University of Dublin, Dublin, Ireland</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>BioSense Institute – Research Institute for Information Technologies in Biosystems, <?xmltex \hack{\break}?> University of Novi Sad, Novi Sad, Serbia</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Dublin City University, Dublin, Ireland </institution>
        </aff>
        <aff id="aff7"><label>a</label><institution>now at:  Technical University of Munich, Munich, Germany</institution>
        </aff>
        <aff id="aff8"><label>b</label><institution>now at:  Institute of Applied Physics and Oeschger Centre for Climate Change Research,<?xmltex \hack{\break}?> University of Bern, Bern, Switzerland</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Konstantina Vasilatou (konstantina.vasilatou@metas.ch) <?xmltex \hack{\break}?> and Gian Lieberherr (gian.lieberherr@meteoswiss.ch)</corresp></author-notes><pub-date><day>8</day><month>December</month><year>2021</year></pub-date>
      
      <volume>14</volume>
      <issue>12</issue>
      <fpage>7693</fpage><lpage>7706</lpage>
      <history>
        <date date-type="received"><day>11</day><month>May</month><year>2021</year></date>
           <date date-type="rev-request"><day>3</day><month>June</month><year>2021</year></date>
           <date date-type="rev-recd"><day>5</day><month>October</month><year>2021</year></date>
           <date date-type="accepted"><day>6</day><month>October</month><year>2021</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2021 Gian Lieberherr et al.</copyright-statement>
        <copyright-year>2021</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021.html">This article is available from https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d1e266">This study presents the first reference calibrations of three commercially available bioaerosol detectors. The Droplet Measurement Technologies WIBS-NEO (new version of the wideband integrated bioaerosol spectrometer), Plair Rapid-E, and Swisens Poleno were compared with a primary standard for particle number concentrations at the Federal Institute for Metrology (METAS). Polystyrene (PSL) spheres were used to assess absolute particle counts for diameters from 0.5 to 10 <inline-formula><mml:math id="M1" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. For the three devices, counting efficiency was found to be strongly dependent on particle size. The results confirm the expected detection range for which the instruments were designed. While the WIBS-NEO achieves its highest efficiency with smaller particles, e.g. 90 % for 0.9 <inline-formula><mml:math id="M2" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter, the Plair Rapid-E performs best for larger particles, with an efficiency of 58 % for particles with a diameter of 10 <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. The Swisens Poleno is also designed for larger particles but operates well from 2 <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. However, the exact counting efficiency of the Poleno could not be evaluated as the cut-off diameter range of the integrated concentrator unit was not completely covered. In further experiments, three different types of fluorescent particles were tested to investigate the fluorescent detection capabilities of the Plair Rapid-E and the Swisens Poleno. Both instruments showed good agreement with the reference data. While the challenge to produce known concentrations of larger particles above 10 <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> or even fresh pollen particles remains, the approach presented in this paper provides a potential standardised validation method that can be used to assess counting efficiency and fluorescence measurements of automatic bioaerosol monitoring devices.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e328">Routine pollen monitoring is carried out across the world, particularly in developed countries, where the prevalence of allergies is highest <xref ref-type="bibr" rid="bib1.bibx31 bib1.bibx24 bib1.bibx5 bib1.bibx1" id="paren.1"/>. At present, monitoring networks rely nearly exclusively on manual instruments developed in the 1950s <xref ref-type="bibr" rid="bib1.bibx12" id="paren.2"/>. These samplers continuously collect airborne particles on a rotating drum, which is removed from the instrument on a regular schedule,<?pagebreak page7694?> usually once per week. Thereafter the tape is disassembled from the drum and pollen manually identified and counted using optical microscopy <xref ref-type="bibr" rid="bib1.bibx9" id="paren.3"/>. The time-consuming nature and professional expertise required for this method restrict both the possible number of stations across a network and the time resolution of data provided to end users (usually daily averages).</p>
      <p id="d1e340">Several automatic bioaerosol monitors have come to market over the past few years, allowing real-time or near-real-time observations at high temporal resolution (for a recent overview see <xref ref-type="bibr" rid="bib1.bibx14" id="altparen.4"/>). These include the Droplet Measurement Technologies WIBS (wideband integrated bioaerosol sensor), which is a three-channel spectrometer <xref ref-type="bibr" rid="bib1.bibx6 bib1.bibx22 bib1.bibx19" id="paren.5"/> that has been widely used for a range of research purposes. Initial studies focused on just the differentiation between fluorescent and non-fluorescent particles <xref ref-type="bibr" rid="bib1.bibx8" id="paren.6"/>, while more recently a typing scheme has been applied to provide information about aerosol fluorescent properties which are linked to different particle types, including bacteria, fungal spores, and pollen <xref ref-type="bibr" rid="bib1.bibx22 bib1.bibx11 bib1.bibx28 bib1.bibx25" id="paren.7"/>. Results, however, varied between different instrument versions, and no classification between different pollen taxa is currently possible. Two more recently developed instruments also based on airflow cytometry, the Plair Rapid-E <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx4 bib1.bibx26" id="paren.8"/> and Swisens Poleno <xref ref-type="bibr" rid="bib1.bibx27" id="paren.9"/>, have shown the potential to classify pollen taxa. This is an essential requirement for pollen monitoring since allergy sufferers, one of the main end user groups of the information these networks provide, are sensitive to specific pollen taxa above particular concentration thresholds <xref ref-type="bibr" rid="bib1.bibx16" id="paren.10"/>.</p>
      <p id="d1e365">As interest grows in using automatic instruments to provide real-time information about airborne pollen concentrations, it is vital that standard calibration methods are developed that can be applied across monitoring networks. Such techniques do not currently exist for automatic pollen monitoring, in part because of the novelty of real-time instruments and also because no method currently exists to aerosolise a known quantity of a particular pollen taxon. This in turn is a result of the fact that pollen particles are considerably larger than the aerosols that are typically monitored in air quality networks and because they are very fragile, being easily broken up into smaller pieces using traditional aerosolising methods <xref ref-type="bibr" rid="bib1.bibx20" id="paren.11"/>. Since the above-mentioned monitoring devices rely on light-induced fluorescence to identify single particles, a validation of the fluorescence response to a known excitation wavelength is also a crucial step in instrument validation.</p>
      <p id="d1e371">In this study we present results from the first reference calibrations of three real-time bioaerosol monitors, the Droplet Measurement Technologies WIBS-NEO (new version of the wideband integrated bioaerosol spectrometer), Plair Rapid-E, and Swisens Poleno, using primary standards. The measurements were carried out from 8–11 April 2019 at the Federal Institute for Metrology (METAS). Section <xref ref-type="sec" rid="Ch1.S2"/> outlines the experimental set-up and instruments used. Section <xref ref-type="sec" rid="Ch1.S3"/> presents the results and a discussion of the performance of each instrument in terms of absolute number counts, counting efficiency, uncertainty and stability, particle size detection, and the fluorescence measurements. The conclusions are provided in Sect. <xref ref-type="sec" rid="Ch1.S4"/>.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Experimental set-up and instruments tested</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Primary standard for particle number concentration at METAS</title>
      <p id="d1e395">The primary standard for particle number concentration at METAS is a large-scale facility designed for calibration of optical and aerodynamic particle size spectrometers (OPSSs and APSSs, respectively). The design has been described in detail elsewhere <xref ref-type="bibr" rid="bib1.bibx13" id="paren.12"/>, and only the main aspects are briefly presented here (Fig. <xref ref-type="fig" rid="Ch1.F1"/>). The experimental set-up consists of three distinct sections: the aerosol generation system, a turbulent-flow tube (aerosol homogeniser), and a reference optical particle counter <xref ref-type="bibr" rid="bib1.bibx13" id="paren.13"/>. Polystyrene (PSL) spheres in the size range 100 <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>–10 <inline-formula><mml:math id="M7" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> are aerosolised using methods based on wet or dry dispersion with commercial and custom-made generators. It is known that PSL suspensions contain additives, such as surfactants to prevent particles from agglomerating. Upon aerosolisation, these additives give rise to so-called residue particles, which can create unwanted peaks in the particle distribution. In such cases, the PSL particles are selected according to size using a differential mobility analyser (DMA; TSI Inc., USA) or an aerodynamic aerosol classifier (AAC; Cambustion Ltd., UK) to filter out unwanted residue particles.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e426">Schematic illustration (simplified) of the primary standard at METAS. MFC, DMA, and AAC stand for mass flow controller, differential mobility analyser, and aerodynamic aerosol classifier, respectively. For a more detailed description of the experimental set-up and the isokinetic sampling probes, readers are referred to <xref ref-type="bibr" rid="bib1.bibx13" id="text.14"/> and <xref ref-type="bibr" rid="bib1.bibx30" id="text.15"/>.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f01.png"/>

        </fig>

      <p id="d1e441">The aerosol homogeniser is a 4 m long custom-made stainless-steel tube with an inner diameter of 16.4 <inline-formula><mml:math id="M8" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">cm</mml:mi></mml:mrow></mml:math></inline-formula>, placed vertically to prevent deposition losses of large particles. Dry filtered air enters the homogeniser from the top (at a fixed flow rate of 120 L/min) and sweeps the PSL particles down the tube. The particles are subsequently mixed by three turbulent air jets. The air jet injection tubes are placed symmetrically around the homogeniser tube pointing downwards at an angle of 60<inline-formula><mml:math id="M9" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>. The flow profile has been characterised using laser Doppler velocimetry (LDV) and was found to be turbulent (plug flow, with negligible effect of the laminar sub-layer). The sampling zone is located 3.0 <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> downstream of the aerosol injection position and accommodates two isokinetic sample probes, one for the device under test and one for the reference optical particle counter. The aerosol homogeneity at the different sampling ports has been determined experimentally to be within 1.1 % in number concentration (95 % confidence level) <xref ref-type="bibr" rid="bib1.bibx13" id="paren.16"/>.</p>
      <?pagebreak page7695?><p id="d1e473">The reference detection system consists of a custom-made optical particle counter placed at the outlet of the aerosol homogeniser <xref ref-type="bibr" rid="bib1.bibx13" id="paren.17"/>. Connection tubes are kept as straight as possible to avoid impaction losses of large particles. The sampled aerosol enters the detection chamber through a nozzle with an orifice of 0.2 <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mm</mml:mi></mml:mrow></mml:math></inline-formula> in diameter and is surrounded by a sheath airflow which prevents the particle beam from diverging. The sampling flow is measured with a traceably calibrated mass flow controller and is kept fixed at 60 mL/min, i.e. at a much lower flow rate than that of the bioaerosol monitors tested. This ensures that coincidence losses, occurring when two or more particles cross the laser beam simultaneously, remain negligible. The laser beam is generated by a continuous-wave laser (Verdi V-5, Coherent, USA) at a wavelength of 532 <inline-formula><mml:math id="M12" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> and is focused at the point of intersection with the aerosol stream using a cylindrical lens. Particles crossing the laser light sheet scatter light, which is then detected by a photomultiplier tube placed at 90<inline-formula><mml:math id="M13" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> to the laser beam.</p>
      <p id="d1e504">Typical particle number concentrations obtained with this set-up range from 0.5 <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> to several hundred particles per cubic centimetre depending on the PSL particle size <xref ref-type="bibr" rid="bib1.bibx13" id="paren.18"/>. To achieve lower concentrations, a dilution unit can be placed upstream of the device under test (DUT). For example, to test the Swisens Poleno device at lower concentrations (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/>), the PSL number concentration in the aerosol homogeniser was set to about 1 <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>; the reference particle counter measured the undiluted aerosol at 1 <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> to ensure enough particles were counted for statistical analysis, while the Poleno device, which has a much higher sampling flow rate, sampled the diluted aerosol flow. Note that for the calculation of the reference concentration, <inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, the aerosol flow sampled by the reference optical particle counter (OPC) is always converted to volumetric flow at ambient temperature and pressure (<inline-formula><mml:math id="M18" display="inline"><mml:mrow><mml:mn mathvariant="normal">23</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M19" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:mn mathvariant="normal">960</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M21" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">hPa</mml:mi></mml:mrow></mml:math></inline-formula>).</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Droplet Measurement Technologies WIBS-NEO</title>
      <p id="d1e618">The WIBS-NEO (new version of the wideband integrated bioaerosol spectrometer) is developed and manufactured by Droplet Measurement Technologies (DMT, Colorado, USA). The device has a sheath flow rate of 2.1 L/min (compared with 2.4 L/min for its predecessor), of which it samples 0.3 L/min and was designed to identify particles in the size range from 0.5–30 <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> in diameter. The WIBS-NEO uses two xenon lamps at 280 and 370 <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> to excite fluorescence and two channels to detect the corresponding signals (310–400 and 420–650 <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>). Furthermore, a 635 <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> continuous laser is used for particle counting and sizing. If particle concentration, as detected by the sizing laser, is too high, the dead time of the xenon lamps can introduce a duty cycle substantially<?pagebreak page7696?> below 100 % in the fluorescence measurement. Few studies exist using the WIBS-NEO given its novelty <xref ref-type="bibr" rid="bib1.bibx15" id="paren.19"/>, although <xref ref-type="bibr" rid="bib1.bibx7" id="text.20"/> recently compared it with the performance of its predecessor, the WIBS-4, with which considerably more studies have been carried out <xref ref-type="bibr" rid="bib1.bibx21 bib1.bibx23 bib1.bibx2" id="paren.21"/>. The WIBS-NEO employed in our study underwent a service at the manufacturer in early 2017.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Plair Rapid-E</title>
      <p id="d1e673">The Rapid-E is developed and manufactured by Plair SA (Geneva, Switzerland). The Rapid-E device samples 2.8 L/min of air and uses a 400 <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> laser to acquire a scattered light signal at 24 angles ranging from 45–135<inline-formula><mml:math id="M27" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>. Each particle then interacts twice with a single pulse of a 337 <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> laser and the resultant fluorescence is recorded in 32 spectral channels, each at a resolution of 14.51 <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> per pixel within a spectral range of 350–800 <inline-formula><mml:math id="M30" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> and with eight sequential acquisitions with a retention of 500 <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ns</mml:mi></mml:mrow></mml:math></inline-formula>. This rapid acquisition allows an estimation of the fluorescence lifetime in four spectral bands (350–400, 420–460, 511–572, 672–800 <inline-formula><mml:math id="M32" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>) and  with a temporal resolution of 2 <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">ns</mml:mi></mml:mrow></mml:math></inline-formula>  <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx4 bib1.bibx26 bib1.bibx3" id="paren.22"/>. For this experiment, the Rapid-E was operated in a mode for particles between 0.5 and 100 <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> in diameter. In case of excessive noise on the detector, the thresholds are automatically adapted by the instrument, leading to a decreased sensitivity to small particles. Besides its research use, the Rapid-E has been employed operationally for airborne pollen monitoring as part of the RealForAll project <xref ref-type="bibr" rid="bib1.bibx29" id="paren.23"/>. The Rapid-E employed in our study underwent a service in 2018.</p>
<sec id="Ch1.S2.SS3.SSS1">
  <label>2.3.1</label><title>Rapid-E particle size determination and spectrum correction</title>
      <p id="d1e765">Particle optical diameter was calculated from the intensity of the scattering signal following the relationship provided by the manufacturer and described by Algorithm 1 in Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>. Essentially, the optical diameter is assumed to be proportional to the overall intensity of scattering signal by summing the detection over all angles for each particle measured. The fluorescence spectrum from each particle was corrected before the analysis following the manufacturers guidelines using Algorithm 2 in Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>.</p>
</sec>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><title>Swisens Poleno</title>
      <p id="d1e781">The Poleno is developed and manufactured by Swisens AG (Lucerne, Switzerland). The Poleno device makes use of two digital holography cameras to reconstruct an in-focus image of each particle. Thereafter, an LED is employed to excite fluorescence at 280 and at 365 <inline-formula><mml:math id="M35" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, after which the resultant fluorescence is recorded in five channels (335–380, 415–455, 465–500, 540–580, and 660–690 <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>). A pump ensures airflows through the instrument at a rate of 40 L/min, while a virtual impactor unit (consisting of multiple virtual impactors in series) serves to concentrate particles with diameter larger than 5 <inline-formula><mml:math id="M37" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>  <xref ref-type="bibr" rid="bib1.bibx27" id="paren.24"/>. According to the manufacturer the maximum enhancement factor of the virtual impactor unit is expected to be 1000 (Swisens, personal communication,  May 2021). This improves counting statistics for large particles which are found at low number concentrations (typically <inline-formula><mml:math id="M38" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 5 <inline-formula><mml:math id="M39" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) in ambient air. At the same time, the virtual impactor filters out small particles (<inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>), thus reducing the risk of coincidence losses. The quality of the images allows a first-level visual verification of particle classification, for example, between pollen and non-pollen, or even in certain cases the identification of easily distinguishable pollen taxa. The Poleno has to date been used only for research purposes, with up to eight different pollen taxa being identified <xref ref-type="bibr" rid="bib1.bibx27" id="paren.25"/>, although it is currently being implemented across the Swiss operational pollen monitoring network. The Poleno  employed in the present study was used as received from the factory.</p>
<sec id="Ch1.S2.SS4.SSS1">
  <label>2.4.1</label><title>Poleno particle size determination</title>
      <p id="d1e865">The manufacturer does not provide a standardised method to determine particle size. We applied two methods to determine particle diameter. The first method is based on the two holographic images taken of each particle. The average area of the particle is calculated from the two images by counting all pixels that make up the particle. Then, assuming that the particles are spherical, the diameter is computed and converted from pixels to micrometres using the resolution of the holographic images (0.6 <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>/pixel). This method is applicable only for particles with diameter of 10 <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> and larger; smaller particles cannot be measured with this method because of limitations in the reconstruction software used at the time.
For small particles, a second method, using the forward-scattering signal from the trigger laser, is applied. This is done in three steps: the part of the raw signal up to a value of 800 is kept, and then a high-pass filter is applied to remove the base of the signal. A cut-off at a value of 7880 is used, which is roughly equivalent to the median of the first part of the signal for 1 <inline-formula><mml:math id="M44" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles. Thereafter, the integral of the remaining signal is computed, and the equation <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:mi>d</mml:mi><mml:mo>=</mml:mo><mml:mi>a</mml:mi><mml:msup><mml:mi>I</mml:mi><mml:mi>b</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula> using the median of the scattered light integral (<inline-formula><mml:math id="M46" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>) for each particle diameter (<inline-formula><mml:math id="M47" display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula>) is fitted, where <inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:mi>a</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">630</mml:mn></mml:mfrac></mml:mstyle></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:mi>b</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.61</mml:mn></mml:mrow></mml:math></inline-formula> (with <inline-formula><mml:math id="M50" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M51" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula> having been determined empirically from the presented data).</p>
</sec>
</sec>
<sec id="Ch1.S2.SS5">
  <label>2.5</label><title>Experimental set-up</title>
      <?pagebreak page7697?><p id="d1e982">Eight different types of PSL particles were used to test a range of sizes and fluorescence. Non-fluorescent particles from 0.5 to 10 <inline-formula><mml:math id="M52" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> were tested as well as red, blue, and plum purple fluorescent particles (see Table <xref ref-type="table" rid="Ch1.T1"/> for further details). The fluorescent particles were chosen to correspond to the detection wavelengths of each of the systems tested. PSL particles with diameters up to 2 <inline-formula><mml:math id="M53" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> were generated by nebulising suspensions, while larger particles (i.e. 5 and 10 <inline-formula><mml:math id="M54" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>) were generated from dry powder using a fluidised bed generator (3400A, TSI Inc., USA). Although necessary for a comprehensive calibration of bioaersol monitors, no standardised method currently exists to produce accurate concentrations of PSL particles of diameter <inline-formula><mml:math id="M55" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 10 <inline-formula><mml:math id="M56" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e1038">PSL sphere types and nominal diameters, <inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">nom</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, used in this study.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">PSL type</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">nom</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M61" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3">Provider</oasis:entry>
         <oasis:entry colname="col4">Catalogue no.</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Non-fluorescent</oasis:entry>
         <oasis:entry colname="col2">0.5</oasis:entry>
         <oasis:entry colname="col3">Thermo Scientific</oasis:entry>
         <oasis:entry colname="col4">3500A</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Non-fluorescent</oasis:entry>
         <oasis:entry colname="col2">0.9</oasis:entry>
         <oasis:entry colname="col3">Duke Scientific Corporation</oasis:entry>
         <oasis:entry colname="col4">1900A</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Non-fluorescent</oasis:entry>
         <oasis:entry colname="col2">1.0</oasis:entry>
         <oasis:entry colname="col3">JSR Corporation</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Plum purple</oasis:entry>
         <oasis:entry colname="col2">2.07</oasis:entry>
         <oasis:entry colname="col3">Bangs Laboratories, Inc.</oasis:entry>
         <oasis:entry colname="col4">FSPP005</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Fluorescent red</oasis:entry>
         <oasis:entry colname="col2">2.0</oasis:entry>
         <oasis:entry colname="col3">Thermo Scientific</oasis:entry>
         <oasis:entry colname="col4">R0200</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Fluorescent blue</oasis:entry>
         <oasis:entry colname="col2">2.1</oasis:entry>
         <oasis:entry colname="col3">Thermo Scientific</oasis:entry>
         <oasis:entry colname="col4">B0200</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Non-fluorescent</oasis:entry>
         <oasis:entry colname="col2">5.0</oasis:entry>
         <oasis:entry colname="col3">Microbeads AS</oasis:entry>
         <oasis:entry colname="col4">CS5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Non-fluorescent</oasis:entry>
         <oasis:entry colname="col2">10.0</oasis:entry>
         <oasis:entry colname="col3">Microbeads AS</oasis:entry>
         <oasis:entry colname="col4">CA10</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e1052">According to the PSL manufacturers, the refractive index of the non-fluorescent and the red and blue fluorescent particles was 1.59 (589 <inline-formula><mml:math id="M58" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, 25 <inline-formula><mml:math id="M59" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>). No information was available regarding the refractive index of the plum purple PSL particles.</p></table-wrap-foot></table-wrap>

      <p id="d1e1251">The number concentration measurements were carried out for each PSL by connecting the DUTs to the sampling outlet of the primary standard described in Sect. <xref ref-type="sec" rid="Ch1.S2.SS1"/>. The nominal particle concentration was set to 0.5–2 <inline-formula><mml:math id="M62" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> with the DUTs sampling the airflow at the same time as the reference OPC. Once the reference concentration was stabilised, one measurement sequence was carried out for each particle size. Each sequence lasted  20 min, yielding around twenty 1 min concentration values per measurement sequence. Averages for both the reference and DUT were computed from the 1 min resolution time series.
The OPC yielded the reference particle number concentration, <inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, with relative expanded uncertainties of 6 %–7 % (coverage factor <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>, 95 % confidence level).
For the measurements with the Rapid-E and WIBS-NEO no dilution of the test PSL aerosol was required. However, for the Poleno, which uses a virtual impactor designed to concentrate particles larger than approximately 5 <inline-formula><mml:math id="M65" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, the device has an upper concentration threshold of about 300 000 <inline-formula><mml:math id="M66" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (0.3 <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>), requiring the use of a dilution system. The commercial dilution unit HDS 561 (Topas GmbH, Germany), which can produce high dilution rates and is suitable for particle counters with high-volume flow, was placed upstream of the Poleno when sampling the 10 <inline-formula><mml:math id="M68" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> PSL particles.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Particle number concentration</title>
<sec id="Ch1.S3.SS1.SSS1">
  <label>3.1.1</label><title>Counting efficiency</title>
      <p id="d1e1365">The counting efficiency, <inline-formula><mml:math id="M69" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, is calculated as <inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msub><mml:mi>E</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">DUT</mml:mi></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula>, with <inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">DUT</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">DUT</mml:mi></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">ref</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, where <inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">DUT</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">ref</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> are the number concentrations measured by the DUT and the reference optical particle counter, respectively, and <inline-formula><mml:math id="M74" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> being the total number of measurements (typically 25). Because of the higher flow rates and therefore higher particle counts registered by the DUT compared to the reference counter, the statistical uncertainties in <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are expected to be small (<inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> %). It must be noted, however, that bioaerosol monitors can also suffer from large systematic errors, for instance, due to uncertainties in the aerosol flow rate, coincidence losses, impaction losses in the sampling system, misalignment of the laser beam, and size-dependent particle losses in the concentrator. These systematic errors are in practice much larger than the statistical uncertainty in <inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> or the uncertainty in <inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (6 %–7 %).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e1530">Average particle concentrations measured by the three devices tested (<inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>), the reference optical particle counter (<inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>), and counting efficiency of the devices tested (<inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>). <inline-formula><mml:math id="M82" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> denotes the expanded uncertainty (95 % confidence level) of the counting efficiency. </p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.85}[.85]?><oasis:tgroup cols="10">
     <oasis:colspec colnum="1" colname="col1" align="left" colsep="1"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right" colsep="1"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right" colsep="1"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:colspec colnum="9" colname="col9" align="right"/>
     <oasis:colspec colnum="10" colname="col10" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">DUT</oasis:entry>
         <oasis:entry namest="col2" nameend="col4" align="center" colsep="1">Poleno </oasis:entry>
         <oasis:entry namest="col5" nameend="col7" align="center" colsep="1">Rapid-E </oasis:entry>
         <oasis:entry namest="col8" nameend="col10" align="center">WIBS-NEO </oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M90" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">nom</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M91" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M93" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M95" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub><mml:mo>±</mml:mo><mml:mi>U</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M98" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M99" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M100" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub><mml:mo>±</mml:mo><mml:mi>U</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M103" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M105" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">DUT</mml:mi></mml:msub><mml:mo>±</mml:mo><mml:mi>U</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M107" display="inline"><mml:mn mathvariant="normal">0.5</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M108" display="inline"><mml:mn mathvariant="normal">0.87</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:msup><mml:mn mathvariant="normal">0</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M111" display="inline"><mml:mn mathvariant="normal">0.76</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:msup><mml:mn mathvariant="normal">0</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M114" display="inline"><mml:mn mathvariant="normal">0.92</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M115" display="inline"><mml:mn mathvariant="normal">0.51</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.54</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M117" display="inline"><mml:mn mathvariant="normal">0.9</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">–<inline-formula><mml:math id="M118" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">–<inline-formula><mml:math id="M119" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">–<inline-formula><mml:math id="M120" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">–<inline-formula><mml:math id="M121" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">–<inline-formula><mml:math id="M122" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">–<inline-formula><mml:math id="M123" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M124" display="inline"><mml:mn mathvariant="normal">1.27</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M125" display="inline"><mml:mn mathvariant="normal">1.13</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.90</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M127" display="inline"><mml:mn mathvariant="normal">1.0</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M128" display="inline"><mml:mn mathvariant="normal">0.88</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M129" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:msup><mml:mn mathvariant="normal">3.32</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M130" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">3.81</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.47</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M131" display="inline"><mml:mn mathvariant="normal">0.97</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:msup><mml:mn mathvariant="normal">0</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8">–<inline-formula><mml:math id="M134" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9">–<inline-formula><mml:math id="M135" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10">–<inline-formula><mml:math id="M136" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M137" display="inline"><mml:mn mathvariant="normal">2.07</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M138" display="inline"><mml:mn mathvariant="normal">1.14</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M139" display="inline"><mml:mn mathvariant="normal">0.93</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.82</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.14</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M141" display="inline"><mml:mn mathvariant="normal">1.14</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M142" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:msup><mml:mn mathvariant="normal">0.03</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M144" display="inline"><mml:mn mathvariant="normal">1.33</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M145" display="inline"><mml:mn mathvariant="normal">1.09</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.82</mml:mn><mml:mo>±</mml:mo><mml:msup><mml:mn mathvariant="normal">0.12</mml:mn><mml:mi mathvariant="normal">e</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M147" display="inline"><mml:mn mathvariant="normal">2.0</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M148" display="inline"><mml:mn mathvariant="normal">1.54</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M149" display="inline"><mml:mn mathvariant="normal">1.50</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M150" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.98</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.13</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M151" display="inline"><mml:mn mathvariant="normal">1.09</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:msup><mml:mn mathvariant="normal">0.05</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M154" display="inline"><mml:mn mathvariant="normal">1.79</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M155" display="inline"><mml:mn mathvariant="normal">1.11</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.61</mml:mn><mml:mo>±</mml:mo><mml:msup><mml:mn mathvariant="normal">0.09</mml:mn><mml:mi mathvariant="normal">e</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M157" display="inline"><mml:mn mathvariant="normal">2.1</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M158" display="inline"><mml:mn mathvariant="normal">1.02</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M159" display="inline"><mml:mn mathvariant="normal">0.95</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M160" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.95</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.18</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M161" display="inline"><mml:mn mathvariant="normal">0.70</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:msup><mml:mn mathvariant="normal">0.005</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M164" display="inline"><mml:mn mathvariant="normal">1.26</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M165" display="inline"><mml:mn mathvariant="normal">1.03</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.83</mml:mn><mml:mo>±</mml:mo><mml:msup><mml:mn mathvariant="normal">0.12</mml:mn><mml:mn mathvariant="normal">5</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M167" display="inline"><mml:mn mathvariant="normal">5.0</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M168" display="inline"><mml:mn mathvariant="normal">2.19</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">17.43</mml:mn><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:mn mathvariant="normal">7.85</mml:mn><mml:mo>±</mml:mo><mml:msup><mml:mn mathvariant="normal">0.38</mml:mn><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M171" display="inline"><mml:mn mathvariant="normal">2.39</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M172" display="inline"><mml:mn mathvariant="normal">0.98</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M173" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.42</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M174" display="inline"><mml:mn mathvariant="normal">1.50</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M175" display="inline"><mml:mn mathvariant="normal">0.86</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.57</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.08</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M177" display="inline"><mml:mn mathvariant="normal">10.0</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M178" display="inline"><mml:mn mathvariant="normal">1.87</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M179" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">214.65</mml:mn><mml:mrow><mml:mi mathvariant="normal">c</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">d</mml:mi></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M180" display="inline"><mml:mrow><mml:mn mathvariant="normal">123.79</mml:mn><mml:mo>±</mml:mo><mml:msup><mml:mn mathvariant="normal">15.53</mml:mn><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M181" display="inline"><mml:mn mathvariant="normal">1.69</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M182" display="inline"><mml:mn mathvariant="normal">0.94</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M183" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.58</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.06</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col8"><inline-formula><mml:math id="M184" display="inline"><mml:mn mathvariant="normal">0.99</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M185" display="inline"><mml:mn mathvariant="normal">0.04</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M186" display="inline"><mml:mrow><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table><?xmltex \begin{scaleboxenv}{.85}[.85]?><table-wrap-foot><p id="d1e1573">
<inline-formula><mml:math id="M83" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula> The particle size is below or at the detection limit of the instrument.
<inline-formula><mml:math id="M84" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula> The measurement sequence was defective or not performed.
<inline-formula><mml:math id="M85" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula> Particle concentrator enhances the concentration of particles larger than 5 <inline-formula><mml:math id="M86" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. Thus counting efficiency values larger than 1 is possible. The enhancement factor is particle-size-dependent and has a theoretical maximum of 1000.
<inline-formula><mml:math id="M87" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">d</mml:mi></mml:msup></mml:math></inline-formula> Measurements were performed using a dilutor with a dilution factor of <inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:mn mathvariant="normal">55</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS5"/> for further details.)
<inline-formula><mml:math id="M89" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">e</mml:mi></mml:msup></mml:math></inline-formula> The suspensions of the fluorescent PSL particles contained a considerable number of additives, giving rise to a large peak of residue particles, which slightly overlapped with the peak of the PSL particles. It is also possible that the PSL particles have a thin organic coating due to the additives. In that case, the PSL diameter after nebulisation of the PSL suspension will be slightly larger than the geometric diameter reported by the manufacturers. The measurement uncertainties have been increased to account for a possible bias in the determination of the counting efficiency.</p></table-wrap-foot><?xmltex \end{scaleboxenv}?></table-wrap>

      <p id="d1e2794">For small particles, the counting efficiency of the WIBS-NEO increases with particle diameter from 54 % for 0.5 <inline-formula><mml:math id="M187" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> to a maximum of 90 % for particles with 0.9 <inline-formula><mml:math id="M188" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter (Table <xref ref-type="table" rid="Ch1.T2"/>). This is in line with the results of <xref ref-type="bibr" rid="bib1.bibx10" id="text.26"/>, who found counting efficiencies of 50 % and 100 % for particles 489  and 690 <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> in diameter, respectively. Beyond the peak at 0.9 <inline-formula><mml:math id="M190" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, the counting efficiency tends to drop with increasing particle diameters (61 %–83 % at 2 <inline-formula><mml:math id="M191" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> and 57 % for 5 <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles; Table <xref ref-type="table" rid="Ch1.T2"/>). The WIBS-NEO appears to reach an upper detection limit for particles larger than 10 <inline-formula><mml:math id="M193" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, detecting just 4 % of the particles with a diameter of 10 <inline-formula><mml:math id="M194" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> compared to the reference counter. This observed drop in the detection rate for bigger particles is somewhat surprising since the WIBS-NEO is expected to be able to detect particles up to 30 <inline-formula><mml:math id="M195" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. Although the exact reasons for this behaviour are unclear, it cannot be ruled out that the specific WIBS-NEO used in our study required a technical service by the manufacturer.</p>
      <p id="d1e2895">The Rapid-E shows a maximum counting efficiency of 58 % for the 10 <inline-formula><mml:math id="M196" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> PSL, while at 5 <inline-formula><mml:math id="M197" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter 42 % of the particles are detected. The lower detection limit was found to be around 2 <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, where only 1 % to 4 % of the particles are detected. At 1 <inline-formula><mml:math id="M199" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter, almost no PSLs are detected by the Rapid-E (Table <xref ref-type="table" rid="Ch1.T2"/>).</p>
      <p id="d1e2940">The Poleno does not detect particles with 0.5 <inline-formula><mml:math id="M200" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter and appears to have its lower detection limit at approximately 1 <inline-formula><mml:math id="M201" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, where the counting efficiency is 3.81 (Table <xref ref-type="table" rid="Ch1.T2"/>). This increased counting efficiency is potentially because the trigger laser was set too sensitively, resulting in noise being counted as particles during the 1 <inline-formula><mml:math id="M202" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> measurement sequence. At 2 <inline-formula><mml:math id="M203" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> the Poleno performs well, with a counting efficiency ranging from 82 %–98 %. However an effect of the concentrator on the measurements for particles at 2 <inline-formula><mml:math id="M204" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter cannot be ruled out.
Note that the counting efficiency of the Poleno strongly depends on the performance of the virtual impactor, also at small particle sizes. Small shifts in the cut-off curve of the impactor can have a large effect on the counting efficiency, for example, at 2 <inline-formula><mml:math id="M205" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. For larger particles, the concentration measured by the Poleno is strongly enhanced due to the concentrator unit. It is expected that the plateau values of the concentrator's enrichment curve are quite robust and could be used to correct concentration values with reasonably small uncertainty. However, the plateau efficiency could not be determined with the tested PSL diameters. For particles with 5 <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter a concentration factor of 7.85 and for the particles with 10 <inline-formula><mml:math id="M207" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter a factor of 123.79 was observed, which is still far below the theoretical maximal enhancement factor of 1000. This indicates that both tested diameters (5 and 10 <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>) are on the lower end of the cut-off curve (Fig. <xref ref-type="fig" rid="Ch1.F2"/>b). It is therefore not recommended to use the values in Table <xref ref-type="table" rid="Ch1.T2"/> to correct the concentration of the Poleno measurements within this size range.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e3043">Counting efficiency for the three devices at different particle sizes. The value at 2 <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter is the mean value of the three measurement sequences at 2.0, 2.07, and 2.1 <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> (i.e. red, plum purple, and blue, respectively).</p></caption>
            <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f02.png"/>

          </fig>

</sec>
<?pagebreak page7698?><sec id="Ch1.S3.SS1.SSS2">
  <label>3.1.2</label><title>Uncertainty and stability</title>
      <p id="d1e3080">A counting efficiency that is too low or high does not mean that a particular device is unable to provide valuable measurements in practice. If the counting efficiency is well known and stable, a scaling curve over the relevant size range can be determined for each instrument. To evaluate whether measurements are indeed scalable, we compute the root mean square error deviation (RMSD) between the scaled reference and DUT counts. The RMSD is a combination of the uncertainties from the reference and DUT measurements as well as from other potential uncertainties related to the experimental set-up. Since we cannot precisely assign the error to each of the potential sources we assume that the DUT is the only source of error, and thus we can interpret the RMSD as an upper bound of the error for each instrument. The lower the RMSD the better the measurements are suited for scaling without significantly increasing the uncertainty. The RMSDs for the different measurement sequences with all particle diameters are given in Table <xref ref-type="table" rid="Ch1.T3"/>.</p>

<?xmltex \floatpos{p}?><table-wrap id="Ch1.T3"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e3088">Root mean square deviation (RMSD) between the scaled DUT and the scaled reference concentration measurements. Both time series where scaled by dividing with their own average before computing the RMSD.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry rowsep="1" namest="col2" nameend="col4" align="center">RMSD (%) </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M214" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">nom</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M215" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">Poleno</oasis:entry>
         <oasis:entry colname="col3">Rapid-E</oasis:entry>
         <oasis:entry colname="col4">WIBS-NEO</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">0.5</oasis:entry>
         <oasis:entry colname="col2">–<inline-formula><mml:math id="M216" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">–<inline-formula><mml:math id="M217" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.11</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">0.9</oasis:entry>
         <oasis:entry colname="col2">–<inline-formula><mml:math id="M218" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">–<inline-formula><mml:math id="M219" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.10</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1.0</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M220" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">0.27</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M221" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">0.89</mml:mn><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M222" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2.07</oasis:entry>
         <oasis:entry colname="col2">0.36</oasis:entry>
         <oasis:entry colname="col3">0.29</oasis:entry>
         <oasis:entry colname="col4">0.14</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2.0</oasis:entry>
         <oasis:entry colname="col2">0.30</oasis:entry>
         <oasis:entry colname="col3">0.26</oasis:entry>
         <oasis:entry colname="col4">0.13</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2.1</oasis:entry>
         <oasis:entry colname="col2">0.39</oasis:entry>
         <oasis:entry colname="col3">0.25</oasis:entry>
         <oasis:entry colname="col4">0.11</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5.0</oasis:entry>
         <oasis:entry colname="col2">0.12</oasis:entry>
         <oasis:entry colname="col3">0.26</oasis:entry>
         <oasis:entry colname="col4">0.25</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">10.0</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M223" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">0.20</mml:mn><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">0.29</oasis:entry>
         <oasis:entry colname="col4">0.25</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e3091"><inline-formula><mml:math id="M211" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula> The particle size is below or at the detection limit of the instrument. <inline-formula><mml:math id="M212" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula> Measurements were performed using a dilutor with a dilution factor of <inline-formula><mml:math id="M213" display="inline"><mml:mrow><mml:mn mathvariant="normal">55</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS5"/> for further details.).</p></table-wrap-foot></table-wrap>

      <?pagebreak page7699?><p id="d1e3373">Out of the three devices tested, the WIBS-NEO is the only one able to perform robust measurements for particles with diameters from 0.5 to 2 <inline-formula><mml:math id="M224" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> (RMSD between 10 % and 14 %). For particles with larger diameters, the RMSD increases to 25 % for the 5 and 10 <inline-formula><mml:math id="M225" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> PSL (Fig. <xref ref-type="fig" rid="Ch1.F3"/>).
The Rapid-E shows an RMSD of 25 %–29 % for particles with diameters between 2 and 10 <inline-formula><mml:math id="M226" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. For the 1 <inline-formula><mml:math id="M227" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles the RMSD of 89 % indicates that the measurements are noisy and thus below the detection limit of the device.
The Poleno shows relatively high RMSD values of 30 %–39 % for the 2 <inline-formula><mml:math id="M228" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles but a lower RMSD of 12 % for the 5 <inline-formula><mml:math id="M229" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles. At 10 <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, the RMSD is slightly higher, at 20 %.</p>
      <p id="d1e3450">Note that all values are based on relatively small statistical samples (<inline-formula><mml:math id="M231" display="inline"><mml:mrow><mml:mo>≤</mml:mo><mml:mn mathvariant="normal">30</mml:mn></mml:mrow></mml:math></inline-formula> measurement points). It also has to be mentioned that the scaling factor can be very sensitive to particle size. In such a case, the capability of determining the particle size becomes an important uncertainty factor when scaling the concentrations.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e3465">Root mean square deviation between normalised DUT and reference measurements. The value for 2 <inline-formula><mml:math id="M232" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> is the mean value of the three measurement sequences with similar diameter (2.07, 2, and 2.1 <inline-formula><mml:math id="M233" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>).</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f03.png"/>

          </fig>

<?xmltex \hack{\newpage}?>
</sec>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Particle size determination</title>
      <p id="d1e3505">Each of the devices tested produces a scattering signal which can be used to estimate the particle size. While the devices are not specifically designed to do so, the measurements provide an indication of how accurate the optical detection of particles is. If the size distribution, measured for a specific PSL size, shows a well-defined peak this gives an indication that the DUT is able to detect particles of that size accurately.</p>
<sec id="Ch1.S3.SS2.SSS1">
  <label>3.2.1</label><title>Droplet Measurement Technologies WIBS-NEO</title>
      <p id="d1e3515">The WIBS-NEO has well-distinguished peaks at 0.9, 1, 5, and 10 <inline-formula><mml:math id="M234" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> (Fig. <xref ref-type="fig" rid="Ch1.F4"/>b and d) and thus appears to provide precise sizing for each particle within this size range. Deviations in (geometric) mean optical diameter measured for a certain PSL sample from nominal geometric diameter are small and within uncertainty in optical sizing methods. The measurement at 0.5 <inline-formula><mml:math id="M235" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> shown in Fig. <xref ref-type="fig" rid="Ch1.F4"/>a may be truncated at the small size end due to the lower size detection limit of the WIBS (see also  counting efficiency results in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1.SSS1"/>). Interestingly, the different types of PSL particles tested appear to impact the measurements to a certain extent. In particular, for the 2 <inline-formula><mml:math id="M236" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles, the red PSLs show a peak at 3.3 <inline-formula><mml:math id="M237" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, while the plum purple and blue PSL peaks are closer to the actual particle optical diameters of 2.3 and 2.2 <inline-formula><mml:math id="M238" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, respectively (Fig. <xref ref-type="fig" rid="Ch1.F4"/>c). The variation in measured (geometric) mean diameters for the three different PSL samples with nominal geometric diameters between 2.0 and 2.1 <inline-formula><mml:math id="M239" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> is considerably greater than the expected optical sizing precision. In particular the red PSLs appear at around 1.6 times the nominal size. This suggests a larger scattering cross-section of the red PSLs compared to the blue and plume purple PSLs at the wavelength of the sizing laser (635 nm).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e3589">Size distribution estimated by the WIBS-NEO for different PSL particles with diameters ranging from 0.5–10 <inline-formula><mml:math id="M240" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>.</p></caption>
            <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f04.png"/>

          </fig>

</sec>
<sec id="Ch1.S3.SS2.SSS2">
  <label>3.2.2</label><title>Plair Rapid-E</title>
      <p id="d1e3616">The Rapid-E was unable to detect 1 <inline-formula><mml:math id="M241" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles and does not show a distinct peak for any of the 2 <inline-formula><mml:math id="M242" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> PSLs either.<?pagebreak page7700?> For these particles the size distribution curve shows no clean peak (Fig. <xref ref-type="fig" rid="Ch1.F5"/>a), indicating that the detection limit is likely above 2 <inline-formula><mml:math id="M243" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> for this device. The peak for the 5 <inline-formula><mml:math id="M244" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles is well defined and therefore indicates that the Rapid-E is able to accurately detect particles in this size. For the size distribution of the 10 <inline-formula><mml:math id="M245" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter particles, a first narrow peak just below 5 <inline-formula><mml:math id="M246" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> and a second broader peak at 10 <inline-formula><mml:math id="M247" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> with a large tail towards smaller diameters can be observed in Fig. <xref ref-type="fig" rid="Ch1.F5"/>b. The large tail towards lower sizes could be an indication of a misalignment of the laser.
The discontinuity of the size distributions at 5 <inline-formula><mml:math id="M248" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> in Fig. <xref ref-type="fig" rid="Ch1.F5"/>b is a direct consequence of using an intensity-to-particle relationship with a discontinuous first derivative (Fig. <xref ref-type="fig" rid="Ch1.F7"/>, Algorithm 1 in Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>). This suggests potential for improving the sizing method for particles with diameters smaller than 10 <inline-formula><mml:math id="M249" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>, but this was not within the scope of this study.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e3723">Size distribution estimated by the Plair Rapid-E for different PSL particles with diameters ranging from 2–10 <inline-formula><mml:math id="M250" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>.</p></caption>
            <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f05.png"/>

          </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e3744">Size distribution estimated by the Swisens Poleno for different PSL particles with diameters ranging from 1–10 <inline-formula><mml:math id="M251" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. The estimates were computed based on the trigger laser signal, except for the “10 <inline-formula><mml:math id="M252" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> (IMG)” curve in <bold>(d)</bold>, where the image-based method was used.</p></caption>
            <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f06.png"/>

          </fig>

</sec>
<sec id="Ch1.S3.SS2.SSS3">
  <label>3.2.3</label><title>Swisens Poleno</title>
      <p id="d1e3784">The Swisens Poleno is unable to detect 0.5 <inline-formula><mml:math id="M253" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter particles. For the 1 <inline-formula><mml:math id="M254" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter PSL particles, the size distribution shows a  well-defined peak at 1.05 <inline-formula><mml:math id="M255" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> (Fig. <xref ref-type="fig" rid="Ch1.F6"/>a), indicating that the device is able to distinguish particles in this size range well. At 2 <inline-formula><mml:math id="M256" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter (Fig. <xref ref-type="fig" rid="Ch1.F6"/>b), the size distributions show well-defined peaks for the red, plum-purple, and blue particles, with slight differences in positioning around 2 <inline-formula><mml:math id="M257" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. The 5 <inline-formula><mml:math id="M258" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> size distributions show a well-defined peak, although the size is slightly overestimated (Fig. <xref ref-type="fig" rid="Ch1.F6"/>c). The 10 <inline-formula><mml:math id="M259" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particle size distribution also shows a well-defined peak, but again the size is overestimated at about 10.7 <inline-formula><mml:math id="M260" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>. The shoulder of the 5 and 10 <inline-formula><mml:math id="M261" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> size distributions at smaller particle sizes may indicate the need to realign the laser and particle beams and/or the detection optics. When comparing the two methods of particle size estimation used for the Poleno device (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS4.SSS1"/>), the method based on the holographic images results in a very clean and sharp peak compared to the trigger signal method (Fig. <xref ref-type="fig" rid="Ch1.F6"/>d). This suggests that the image-based method should be used for the Poleno device for large particles.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><?xmltex \currentcnt{7}?><?xmltex \def\figurename{Figure}?><label>Figure 7</label><caption><p id="d1e3891">The relationship between light-scattering intensity and particle size for the Plair Rapid-E as recommended by the manufacturer. Note that two different equations are used to calculate size for particles smaller and larger than 5 <inline-formula><mml:math id="M262" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> in diameter, respectively.</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f07.png"/>

          </fig>

</sec>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Fluorescence measurements</title>
      <p id="d1e3919">The fluorescent response after excitation at different wavelengths is evaluated on the DUT's using three different PSL particles (blue, plum purple, and red) with 2 <inline-formula><mml:math id="M263" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter. These measurements were then compared to reference data from the Max Planck Institute for Chemistry <xref ref-type="bibr" rid="bib1.bibx18" id="paren.27"/>. The intensity values obtained from the devices tested were scaled to the reference curve with high spectral resolution. The peaks due to first- and second-order elastic scattering were removed from the reference data as well as from each device tested (e.g. for excitation at <inline-formula><mml:math id="M264" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">365</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M265" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, the peaks at <inline-formula><mml:math id="M266" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">365</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M267" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> and at <inline-formula><mml:math id="M268" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">730</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M269" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> were removed).</p>
      <p id="d1e3998">Since the WIBS-NEO only detects signals in two channels (310–400 and 420–650 <inline-formula><mml:math id="M270" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>) a maximum of two data points per excitation wavelength are obtained. One of these points is used to scale to the reference values, so only one value remains to evaluate the signal. No meaningful analysis is thus<?pagebreak page7701?> possible, and no further assessment was performed for this device for fluorescence.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><?xmltex \def\figurename{Figure}?><label>Figure 8</label><caption><p id="d1e4011">Comparison of the Rapid-E fluorescence measurements (DUT) with the reference measurements from <xref ref-type="bibr" rid="bib1.bibx19" id="text.28"/> for <bold>(a)</bold> plum purple PSL particles with expected peak at 422 <inline-formula><mml:math id="M271" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, <bold>(b)</bold> blue PSL particles with expected peak at 447 <inline-formula><mml:math id="M272" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, and <bold>(c)</bold> red PSL particles with expected peak at 582 <inline-formula><mml:math id="M273" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>. All measurements are scaled to a maximum value of 1.</p></caption>
          <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f08.png"/>

        </fig>

<sec id="Ch1.S3.SS3.SSS1">
  <label>3.3.1</label><title>Plair Rapid-E</title>
      <p id="d1e4065">The Rapid-E's fluorescence spectra correspond relatively well with those from the reference data (Fig. <xref ref-type="fig" rid="Ch1.F8"/>). For the plum purple PSL particles (<inline-formula><mml:math id="M274" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">425</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M275" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>) both the reference and Rapid-E exhibit a broad peak in the range <inline-formula><mml:math id="M276" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">400</mml:mn></mml:mrow></mml:math></inline-formula>–450 <inline-formula><mml:math id="M277" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, with the Rapid-E slightly shifted towards longer wavelengths. For the blue PSL particles (<inline-formula><mml:math id="M278" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">447</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M279" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>) the opposite is true, with the Rapid-E signal slightly shifted towards shorter wavelengths and with a significant tail in this direction. The red PSL particles (<inline-formula><mml:math id="M280" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">579</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M281" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>) show a less defined peak in the expected range (around 580 <inline-formula><mml:math id="M282" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>), but there is a strong signal from 400–450 <inline-formula><mml:math id="M283" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>, where no peak is seen in the reference data.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e4170">Number and percentage of particles with “almost correct” fluorescence peak position measured by the Rapid-E. Two cases are distinguished: <inline-formula><mml:math id="M284" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>10 and <inline-formula><mml:math id="M285" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>20 <inline-formula><mml:math id="M286" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> deviation from the reference peak wavelength. </p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left" colsep="1"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right" colsep="1"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:thead>
       <oasis:row>

         <oasis:entry rowsep="1" colname="col1" morerows="1">Group</oasis:entry>

         <oasis:entry rowsep="1" colname="col2" morerows="1" align="right">Total particles</oasis:entry>

         <oasis:entry rowsep="1" colname="col3" morerows="1" align="right">Reference peak [<inline-formula><mml:math id="M287" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>]</oasis:entry>

         <oasis:entry rowsep="1" namest="col4" nameend="col5" align="center" colsep="1">Measured peak [<inline-formula><mml:math id="M288" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula>] </oasis:entry>

         <oasis:entry rowsep="1" namest="col6" nameend="col7" align="center">Particles with correct peak </oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry colname="col4">Tolerance</oasis:entry>

         <oasis:entry colname="col5">Selected peak</oasis:entry>

         <oasis:entry colname="col6">Number</oasis:entry>

         <oasis:entry colname="col7">Percentage</oasis:entry>

       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>

         <oasis:entry colname="col1" morerows="1">Plum purple</oasis:entry>

         <oasis:entry colname="col2" morerows="1" align="right">1571</oasis:entry>

         <oasis:entry colname="col3" morerows="1" align="right">425</oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M289" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>10</oasis:entry>

         <oasis:entry colname="col5">422</oasis:entry>

         <oasis:entry colname="col6">299</oasis:entry>

         <oasis:entry colname="col7">19.0</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M290" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>20</oasis:entry>

         <oasis:entry colname="col5">408, 422, 437</oasis:entry>

         <oasis:entry colname="col6">761</oasis:entry>

         <oasis:entry colname="col7">48.44</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1" morerows="1">Red</oasis:entry>

         <oasis:entry colname="col2" morerows="1" align="right">2766</oasis:entry>

         <oasis:entry colname="col3" morerows="1" align="right">579</oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M291" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>10</oasis:entry>

         <oasis:entry colname="col5">582</oasis:entry>

         <oasis:entry colname="col6">110</oasis:entry>

         <oasis:entry colname="col7">3.98</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M292" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>20</oasis:entry>

         <oasis:entry colname="col5">567, 582, 596</oasis:entry>

         <oasis:entry colname="col6">407</oasis:entry>

         <oasis:entry colname="col7">14.71</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1" morerows="1">Blue</oasis:entry>

         <oasis:entry colname="col2" morerows="1" align="right">274</oasis:entry>

         <oasis:entry colname="col3" morerows="1" align="right">447</oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M293" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>10</oasis:entry>

         <oasis:entry colname="col5">437, 451</oasis:entry>

         <oasis:entry colname="col6">86</oasis:entry>

         <oasis:entry colname="col7">30.66</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M294" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>20</oasis:entry>

         <oasis:entry colname="col5">437, 451, 466</oasis:entry>

         <oasis:entry colname="col6">102</oasis:entry>

         <oasis:entry colname="col7">36.96</oasis:entry>

       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e4427">Table <xref ref-type="table" rid="Ch1.T4"/> shows the percentage of particles measured by the Rapid-E with peak fluorescence emission at the correct wavelength. Despite the spectra not showing peaks at the expected wavelengths, a notable number of measured particles show maximum fluorescence at these wavelengths.</p>
</sec>
<?pagebreak page7702?><sec id="Ch1.S3.SS3.SSS2">
  <label>3.3.2</label><title>Swisens Poleno</title>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9" specific-use="star"><?xmltex \currentcnt{9}?><?xmltex \def\figurename{Figure}?><label>Figure 9</label><caption><p id="d1e4442">Comparison of the reference (REF) fluorescence measurements from <xref ref-type="bibr" rid="bib1.bibx19" id="text.29"/>  to the measurements with the Poleno instrument (DUT). All measurements are scaled to a maximum value of 1.</p></caption>
            <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-f09.png"/>

          </fig>

      <p id="d1e4454">The reference data, when averaged for the different Poleno windows, are very similar for all excitation wavelengths once the first- and second-order elastic scattering peaks have been removed (Fig. <xref ref-type="fig" rid="Ch1.F9"/>). Overall, the Poleno compares well with the reference data for the three different PSLs tested. The limited spectral resolution of the device does not allow the same level of comparison as the Rapid-E; however, the available measurement points are all close to the reference data. Note that the values for the 335–380 <inline-formula><mml:math id="M295" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> detection window are discarded as a result of the first-order elastic scattering, so no points are shown for this wavelength range.</p><?xmltex \hack{\newpage}?>
</sec>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e4478">Three commercially available bioaerosol monitors were tested for their ability to detect and count particles at different sizes and for the accuracy of their fluorescence measurements. A range of different polystyrene (PSL) particles were tested in a state-of-the-art calibration facility at the Federal Institute for Metrology (METAS).</p>
      <p id="d1e4481">The DMT WIBS-NEO showed very good counting efficiency for particles with diameters of 1 <inline-formula><mml:math id="M296" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>; however, as particle size increases its detection performance was shown to drop considerably. This result was somewhat unexpected, and this issue remains to be investigated in more depth. The Plair Rapid-E was shown to be better suited for detecting larger particles, with detection performance increasing with particle size. The counting efficiency of the Poleno detection system could not be accurately estimated since the integrated virtual impactor unit was found to work at the lower end of the cut-off curve for the tested particle sizes. In order to determine the plateau efficiency of the virtual impactor unit, further measurements with larger particle sizes are necessary.</p>
      <?pagebreak page7704?><p id="d1e4494">The RMSD analysis of the different measurement sequences confirms that the WIBS-NEO performs best for smaller particles (<inline-formula><mml:math id="M297" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M298" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>). Only the measurement sequence from the Poleno at 5 <inline-formula><mml:math id="M299" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> and possibly at 10 <inline-formula><mml:math id="M300" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> showed similarly low RMSD values (10 %–20 %). The particle size determination of the WIBS-NEO agreed with the reference, with well-shaped particle size distribution curves for all tested particles. However, for the fluorescent 2 <inline-formula><mml:math id="M301" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> particles, the red particles were estimated to be considerably larger than the blue and plum purple particles. Whether this is an effect of a stronger scattering response due to the particle colour or an effect of the particle being coated in additives and becoming physically bigger is speculative at this point and should be investigated further. For the Rapid-E device, the algorithm for determining particle size delivered by the manufacturer led to some artefacts in the size distribution curve. This method could be improved to obtain more robust results since the measurements are likely to be sufficient to do so. Finally, two methods of size determination were tested for the Poleno device. It was shown that the image-based approach works better than the scattering signal one; however, it can only be applied to larger particles.</p>
      <p id="d1e4549">Results show that the detection limit of the WIBS-NEO is below 0.5 <inline-formula><mml:math id="M302" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter, the smallest particle size tested here. In contrast, the minimum detection limits for the other two instruments appear to be between 0.5  and 1 <inline-formula><mml:math id="M303" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> in diameter for the Poleno and between 2  and 5 <inline-formula><mml:math id="M304" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> diameter for the Rapid-E. More studies are needed to investigate the unit-to-unit variability in the Poleno, Rapid-E, and WIBS-NEO bioaerosol monitors. It is known that inadequate maintenance can affect both the sizing accuracy and the counting efficiency of light-scattering instruments <xref ref-type="bibr" rid="bib1.bibx30" id="paren.30"/>.</p>
      <p id="d1e4586">The Rapid-E fluorescence measurements compare well with the reference data, even tough the signal-to-noise ratio seems to be elevated for the red PSL particles. The Poleno device aligns well with the reference data and shows a very good correlation. Nevertheless, the coarse spectral resolution of the Poleno does not allow as precise a comparison as for the Rapid-E. A validation of the WIBS-NEO fluorescence observations was not possible because of the very low spectral resolution of the device. In future the stability of the fluorescence measurements in time and amongst different devices of the same type should be tested.</p>
      <p id="d1e4589">Our results show that the three devices tested all have different strengths and weaknesses which need to be taken into account when considering an instrument for a specific application. In terms of pollen monitoring, it would be relevant to test even larger particles (e.g. 20 <inline-formula><mml:math id="M305" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula>), particularly since the Rapid-E and Poleno were developed to detect airborne pollen, which typically has diameters ranging from 10–100 <inline-formula><mml:math id="M306" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> in size. At present, no methods exist to produce accurate concentrations of PSL particles of this size nor, of even greater interest, of fresh pollen particles. These challenges remain to be resolved to allow standardised calibration of bioaerosol monitors for their target particle size and thus to more fully understand what is present under real atmospheric conditions.</p>
</sec>

      
      </body>
    <back><app-group>

<app id="App1.Ch1.S1">
  <?xmltex \currentcnt{A}?><label>Appendix A</label><title>Algorithms</title>
      <p id="d1e4624"><?xmltex \igopts{width=241.848425pt}?><inline-graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-g01.png"/><?xmltex \hack{\\}?><?xmltex \hack{\newpage}?><?xmltex \igopts{width=241.848425pt}?><inline-graphic xlink:href="https://amt.copernicus.org/articles/14/7693/2021/amt-14-7693-2021-g02.png"/></p>
</app>
  </app-group><notes notes-type="codedataavailability"><title>Code and data availability</title>

      <p id="d1e4640">Data and algorithms presented in this paper are experimental and subject to further development. They are available for research purposes on request to the authors of the paper.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e4646">KA, BenC, FT, and KV designed and carried out the experiments. KA, KV, JM, DO, BS, AM, GL, BerC, and FT contributed to the data analysis. All authors contributed to the interpretation of the results and to writing this paper.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e4652">The contact author has declared that neither they nor their co-authors have any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e4658">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e4664">This work is a contribution to the EUMETNET AutoPollen Programme.
Part of this work was carried out within the Aeromet 2 project, which has received funding from the EMPIR programme. The EMPIR programme is co-financed by the participating states and from the European Union's Horizon 2020 research and innovation programme.
Branko Sikoparija acknowledges financial support from the Ministry of Education, Science and Technological Development of the Republic of Serbia and the BREATHE project funded by the Science Fund of the Republic of Serbia.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e4669">This research has been supported by the European Metrology Programme for Innovation and Research through the grant agreement 19ENV08 AEROMET
II; the Ministarstvo Prosvete, Nauke i Tehnološkog Razvoja (grant no.<?pagebreak page7705?> 451-03-9/2021-14/200358); and the Science Fund of the Republic of Serbia (grant no. 6039613).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e4675">This paper was edited by Zamin A. Kanji and reviewed by Ghislain Motos and one anonymous referee.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><?xmltex \def\ref@label{{Buters et~al.(2018)Buters, Antunes, Galveias, Bergmann, Thibaudon,
Gal{\'{a}}n et~al.}}?><label>Buters et al.(2018)Buters, Antunes, Galveias, Bergmann, Thibaudon,
Galán et al.</label><?label buters2018pollen?><mixed-citation>Buters, J., Antunes, C., Galveias, A., Bergmann, K., Thibaudon, M., Galán,
C., Galán, C., Schmidt Weber, C., and Oteros, J.: Pollen and spore monitoring in the world, Clin.
Transl. Allergy, 8, <ext-link xlink:href="https://doi.org/10.1186/s13601-018-0197-8" ext-link-type="DOI">10.1186/s13601-018-0197-8</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx2"><?xmltex \def\ref@label{{Calvo et~al.(2018)Calvo, Baumgardner, Castro, Fernández-González,
Vega-Maray, Valencia-Barrera, Oduber, Blanco-Alegre, and Fraile}}?><label>Calvo et al.(2018)Calvo, Baumgardner, Castro, Fernández-González,
Vega-Maray, Valencia-Barrera, Oduber, Blanco-Alegre, and Fraile</label><?label calvo2018?><mixed-citation>Calvo, A., Baumgardner, D., Castro, A., Fernández-González, D., Vega-Maray,
A., Valencia-Barrera, R., Oduber, F., Blanco-Alegre, C., and Fraile, R.:
Daily behavior of urban Fluorescing Aerosol Particles in northwest Spain,
Atmos. Environ., 184, 262–277,
<ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2018.04.027" ext-link-type="DOI">10.1016/j.atmosenv.2018.04.027</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx3"><?xmltex \def\ref@label{{Chappuis et~al.(2019)Chappuis, Tummon, Clot, Konzelmann, Calpini, and
Crouzy}}?><label>Chappuis et al.(2019)Chappuis, Tummon, Clot, Konzelmann, Calpini, and
Crouzy</label><?label Chappuis2019AutomaticPM?><mixed-citation>
Chappuis, C., Tummon, F., Clot, B., Konzelmann, T., Calpini, B., and Crouzy,
B.: Automatic pollen monitoring: first insights from hourly data,
Aerobiologia, 36, 159–170, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx4"><?xmltex \def\ref@label{{Crouzy et~al.(2016)Crouzy, M., Konzelmann, Calpini, and
Clot}}?><label>Crouzy et al.(2016)Crouzy, M., Konzelmann, Calpini, and
Clot</label><?label paper1?><mixed-citation>
Crouzy, B., M., S., Konzelmann, T., Calpini, B., and Clot, B.: All-optical
automatic pollen indentification: Towards an operational system, Atmos.
Environ., 140, 202–212, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx5"><?xmltex \def\ref@label{{D'Amato et~al.(2007)D'Amato, Cecchi, Bonini, Nunes, Annesi-Maesano,
Behrendt, Liccardi, Popov, and Van~Cauwenberge}}?><label>D'Amato et al.(2007)D'Amato, Cecchi, Bonini, Nunes, Annesi-Maesano,
Behrendt, Liccardi, Popov, and Van Cauwenberge</label><?label damato2?><mixed-citation>D'Amato, G., Cecchi, L., Bonini, S., Nunes, C., Annesi-Maesano, I., Behrendt,
H., Liccardi, G., Popov, T., and Van Cauwenberge, P.: Allergenic pollen and
pollen allergy in Europe, Allergy, 62, 976–990,
<ext-link xlink:href="https://doi.org/10.1111/j.1398-9995.2007.01393.x" ext-link-type="DOI">10.1111/j.1398-9995.2007.01393.x</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx6"><?xmltex \def\ref@label{{Foot et~al.(2008)Foot, Kaye, Stanley, Barrington, Gallagher, and
Gabey}}?><label>Foot et al.(2008)Foot, Kaye, Stanley, Barrington, Gallagher, and
Gabey</label><?label foot2008low?><mixed-citation>
Foot, V. E., Kaye, P. H., Stanley, W. R., Barrington, S. J., Gallagher, M., and
Gabey, A.: Low-cost real-time multiparameter bio-aerosol sensors, in:
Optically Based Biological and Chemical Detection for Defence IV,International Society for Optics and Photonics, vol. 7116,
p. 71160I, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx7"><?xmltex \def\ref@label{{Forde et~al.(2019)Forde, Gallagher, Walker, Foot, Attwood, Granger,
Sarda-Estève, Stanley, Kaye, and Topping}}?><label>Forde et al.(2019)Forde, Gallagher, Walker, Foot, Attwood, Granger,
Sarda-Estève, Stanley, Kaye, and Topping</label><?label forde2019?><mixed-citation>Forde, E., Gallagher, M., Walker, M., Foot, V., Attwood, A., Granger, G.,
Sarda-Estève, R., Stanley, W., Kaye, P., and Topping, D.: Intercomparison of
Multiple UV-LIF Spectrometers Using the Aerosol Challenge Simulator,
Atmosphere, 10, 797, <ext-link xlink:href="https://doi.org/10.3390/atmos10120797" ext-link-type="DOI">10.3390/atmos10120797</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx8"><?xmltex \def\ref@label{{Gabey et~al.(2010)Gabey, Gallagher, Whitehead, Dorsey, Kaye, and
Stanley}}?><label>Gabey et al.(2010)Gabey, Gallagher, Whitehead, Dorsey, Kaye, and
Stanley</label><?label gabey2010measurements?><mixed-citation>Gabey, A. M., Gallagher, M. W., Whitehead, J., Dorsey, J. R., Kaye, P. H., and Stanley, W. R.: Measurements and comparison of primary biological aerosol above and below a tropical forest canopy using a dual channel fluorescence spectrometer, Atmos. Chem. Phys., 10, 4453–4466, <ext-link xlink:href="https://doi.org/10.5194/acp-10-4453-2010" ext-link-type="DOI">10.5194/acp-10-4453-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx9"><?xmltex \def\ref@label{{Gal\'{a}n et~al.(2014)Gal\'{a}n, Smith, Thibaudon, Frenguelli, Oteros,
Gehrig, Berger, Clot, and Brandao}}?><label>Galán et al.(2014)Galán, Smith, Thibaudon, Frenguelli, Oteros,
Gehrig, Berger, Clot, and Brandao</label><?label minimal?><mixed-citation>Galán, C., Smith, M., Thibaudon, M., Frenguelli, G., Oteros, J., Gehrig, R.,
Berger, U., Clot, B., and Brandao, R.: Pollen monitoring: minimum
requirements and reproducibility of analysis, Aerobiologia, 30, 385–395,
<ext-link xlink:href="https://doi.org/10.1007/s10453-014-9335-5" ext-link-type="DOI">10.1007/s10453-014-9335-5</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx10"><?xmltex \def\ref@label{{Healy et~al.(2012)Healy, O’Connor, and
Sodeau}}?><label>Healy et al.(2012)Healy, O’Connor, and
Sodeau</label><?label healy2012measurement?><mixed-citation>
Healy, D. A., O’Connor, D. J., and Sodeau, J. R.: Measurement of the particle
counting efficiency of the “Waveband Integrated Bioaerosol Sensor” model
number 4 (WIBS-4), J. Aerosol Scie., 47, 94–99, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx11"><?xmltex \def\ref@label{{Hernandez et~al.(2016)Hernandez, Perring, McCabe, Kok, Granger, and
Baumgardner}}?><label>Hernandez et al.(2016)Hernandez, Perring, McCabe, Kok, Granger, and
Baumgardner</label><?label discussion2?><mixed-citation>Hernandez, M., Perring, A. E., McCabe, K., Kok, G., Granger, G., and Baumgardner, D.: Chamber catalogues of optical and fluorescent signatures distinguish bioaerosol classes, Atmos. Meas. Tech., 9, 3283–3292, <ext-link xlink:href="https://doi.org/10.5194/amt-9-3283-2016" ext-link-type="DOI">10.5194/amt-9-3283-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx12"><?xmltex \def\ref@label{{Hirst(1952)}}?><label>Hirst(1952)</label><?label hirst?><mixed-citation>Hirst, J. M.: An automatic volumetric spore trap, Ann. Appl. Biol.,
39, 257–265, <ext-link xlink:href="https://doi.org/10.1111/j.1744-7348.1952.tb00904.x" ext-link-type="DOI">10.1111/j.1744-7348.1952.tb00904.x</ext-link>, 1952.</mixed-citation></ref>
      <ref id="bib1.bibx13"><?xmltex \def\ref@label{{Horender et~al.(2019)Horender, Auderset, and Vasilatou}}?><label>Horender et al.(2019)Horender, Auderset, and Vasilatou</label><?label metal?><mixed-citation>Horender, S., Auderset, K., and Vasilatou, K.: Facility for calibration of
optical and condensation particle counters based on a turbulent aerosol
mixing tube and a reference optical particle counter, Rev. Sci.
Instrum., 90, 075111, <ext-link xlink:href="https://doi.org/10.1063/1.5095853" ext-link-type="DOI">10.1063/1.5095853</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx14"><?xmltex \def\ref@label{{Huffman et~al.(2019)Huffman, Perring, Savage, Clot, Crouzy, Tummon,
Shoshanim, Damit, Schneider, Sivaprakasam, Zawadowicz, Crawford, Gallagher,
Topping, Doughty, Hill, and Pan}}?><label>Huffman et al.(2019)Huffman, Perring, Savage, Clot, Crouzy, Tummon,
Shoshanim, Damit, Schneider, Sivaprakasam, Zawadowicz, Crawford, Gallagher,
Topping, Doughty, Hill, and Pan</label><?label intro2?><mixed-citation>Huffman, J. A., Perring, A. E., Savage, N. J., Clot, B., Crouzy, B., Tummon,
F., Shoshanim, O., Damit, B., Schneider, J., Sivaprakasam, V., Zawadowicz,
M. A., Crawford, I., Gallagher, M., Topping, D., Doughty, D. C., Hill, S. C.,
and Pan, Y.: Real-time sensing of bioaerosols: Review and current
perspectives, Aerosol Sci. Tech., 54, 465–495,
<ext-link xlink:href="https://doi.org/10.1080/02786826.2019.1664724" ext-link-type="DOI">10.1080/02786826.2019.1664724</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx15"><?xmltex \def\ref@label{{Hughes et~al.(2020)Hughes, Mampage, Jones, Liu, and
Stone}}?><label>Hughes et al.(2020)Hughes, Mampage, Jones, Liu, and
Stone</label><?label hughes2020?><mixed-citation>Hughes, D. D., Mampage, C. B. A., Jones, L. M., Liu, Z., and Stone, E. A.:
Characterization of Atmospheric Pollen Fragments during Springtime
Thunderstorms, Environ. Sci. Tech. Let., 7, 409–414,
<ext-link xlink:href="https://doi.org/10.1021/acs.estlett.0c00213" ext-link-type="DOI">10.1021/acs.estlett.0c00213</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx16"><?xmltex \def\ref@label{{Jaeger(2006)}}?><label>Jaeger(2006)</label><?label jaeger2006trouble?><mixed-citation>
Jaeger, S.: The trouble with threshold values for allergy forecasts,
Aerobiological Monographs, Towards a comprehensive vision, edited by: Clot,
B., Comtois, P., and Escamilla-Garcia, B., MeteoSwiss (CH) and University of Montreal (CA), 233–245, ISBN: 978-2-8399-0466-7, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx17"><?xmltex \def\ref@label{{Kiselev et~al.(2013)Kiselev, Bonacina, and Wolf}}?><label>Kiselev et al.(2013)Kiselev, Bonacina, and Wolf</label><?label patent_r?><mixed-citation>Kiselev, D., Bonacina, L., and Wolf, J.-P.: A flash-lamp based device for
fluorescence detection and identification of individual pollen grains, Rev. Sci. Instrum., 84, 033302,
<ext-link xlink:href="https://doi.org/10.1063/1.4793792" ext-link-type="DOI">10.1063/1.4793792</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx18"><?xmltex \def\ref@label{{K{\"{o}}nemann et~al.(2018)K{\"{o}}nemann, Savage, Huffman, and
P{\"{o}}hlker}}?><label>Könemann et al.(2018)Könemann, Savage, Huffman, and
Pöhlker</label><?label konemann2018characterization?><mixed-citation>Könemann, T., Savage, N. J., Huffman, J. A., and Pöhlker, C.: Characterization of steady-state fluorescence properties of polystyrene latex spheres using off- and online spectroscopic methods, Atmos. Meas. Tech., 11, 3987–4003, <ext-link xlink:href="https://doi.org/10.5194/amt-11-3987-2018" ext-link-type="DOI">10.5194/amt-11-3987-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx19"><?xmltex \def\ref@label{{K{\"{o}}nemann et~al.(2019)}}?><label>Könemann et al.(2019)</label><?label konemann2019spectral?><mixed-citation>Könemann, T., Savage, N., Klimach, T., Walter, D., Fröhlich-Nowoisky, J., Su, H., Pöschl, U., Huffman, J. A., and Pöhlker, C.: Spectral Intensity Bioaerosol Sensor (SIBS): an instrument for spectrally resolved fluorescence detection of single particles in real time, Atmos. Meas. Tech., 12, 1337–1363, <ext-link xlink:href="https://doi.org/10.5194/amt-12-1337-2019" ext-link-type="DOI">10.5194/amt-12-1337-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx20"><?xmltex \def\ref@label{{L{\"{o}}ndahl(2014)}}?><label>Löndahl(2014)</label><?label Loendahl2014?><mixed-citation>Löndahl, J.: Physical and Biological Properties of Bioaerosols,
Springer New York, New York, NY, 33–48, <ext-link xlink:href="https://doi.org/10.1007/978-1-4419-5582-1_3" ext-link-type="DOI">10.1007/978-1-4419-5582-1_3</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx21"><?xmltex \def\ref@label{{O'Connor et~al.(2014)O'Connor, Healy, Hellebust, Buters, and
Sodeau}}?><label>O'Connor et al.(2014)O'Connor, Healy, Hellebust, Buters, and
Sodeau</label><?label oconnor2014?><mixed-citation>O'Connor, D. J., Healy, D. A., Hellebust, S., Buters, J. T. M., and Sodeau,
J. R.: Using the WIBS-4 (Waveband Integrated Bioaerosol Sensor) Technique for
the On-Line Detection of Pollen Grains, Aerosol Sci. Tech., 48, 341–349,
<ext-link xlink:href="https://doi.org/10.1080/02786826.2013.872768" ext-link-type="DOI">10.1080/02786826.2013.872768</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx22"><?xmltex \def\ref@label{{Perring et~al.(2015{\natexlab{a}})Perring, Schwarz, Baumgardner,
Hernandez, Spracklen, Heald, Gao, Kok, McMeeking, McQuaid, and Fahey}}?><label>Perring et al.(2015a)Perring, Schwarz, Baumgardner,
Hernandez, Spracklen, Heald, Gao, Kok, McMeeking, McQuaid, and Fahey</label><?label JGRA?><mixed-citation>Perring, A. E., Schwarz, J. P., Baumgardner, D., Hernandez, M. T., Spracklen,
D. V., Heald, C. L., Gao, R. S., Kok, G., McMeeking, G. R., McQuaid, J. B.,
and Fahey, D. W.: Airborne observations of regional variation in fluorescent
aerosol across the United States, J. Geophys. Res.-Atmos., 120, 1153–1170, <ext-link xlink:href="https://doi.org/10.1002/2014JD022495" ext-link-type="DOI">10.1002/2014JD022495</ext-link>,
2015a.</mixed-citation></ref>
      <ref id="bib1.bibx23"><?xmltex \def\ref@label{{Perring et~al.(2015{\natexlab{b}})Perring, Schwarz, Baumgardner,
Hernandez, Spracklen, Heald, Gao, Kok, McMeeking, McQuaid, and
Fahey}}?><label>Perring et al.(2015b)Perring, Schwarz, Baumgardner,
Hernandez, Spracklen, Heald, Gao, Kok, McMeeking, McQuaid, and
Fahey</label><?label perring2015?><mixed-citation>Perring, A. E., Schwarz, J. P., Baumgardner, D., Hernandez, M. T., Spracklen,
D. V.<?pagebreak page7706?>, Heald, C. L., Gao, R. S., Kok, G., McMeeking, G. R., McQuaid, J. B.,
and Fahey, D. W.: Airborne observations of regional variation in fluorescent
aerosol across the United States, J. Geophys. Res.-Atmos., 120, 1153–1170, <ext-link xlink:href="https://doi.org/10.1002/2014JD022495" ext-link-type="DOI">10.1002/2014JD022495</ext-link>,
2015b.</mixed-citation></ref>
      <ref id="bib1.bibx24"><?xmltex \def\ref@label{{Ring et~al.(2001)Ring, Kr\"{a}mer, Sch\"{a}fer, and Behrent}}?><label>Ring et al.(2001)Ring, Krämer, Schäfer, and Behrent</label><?label ring?><mixed-citation>Ring, J., Krämer, U., Schäfer, T., and Behrent, H.: Why are allergies
increasing?, Curr. Opin. Immunol., 13, 701–708,
<ext-link xlink:href="https://doi.org/10.1016/S0952-7915(01)00282-5" ext-link-type="DOI">10.1016/S0952-7915(01)00282-5</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bibx25"><?xmltex \def\ref@label{{Ruske et~al.(2018)Ruske, Topping, Foot, Morse, and
Gallagher}}?><label>Ruske et al.(2018)Ruske, Topping, Foot, Morse, and
Gallagher</label><?label ruske2018_ML_WIBS?><mixed-citation>Ruske, S., Topping, D. O., Foot, V. E., Morse, A. P., and Gallagher, M. W.: Machine learning for improved data analysis of biological aerosol using the WIBS, Atmos. Meas. Tech., 11, 6203–6230, <ext-link xlink:href="https://doi.org/10.5194/amt-11-6203-2018" ext-link-type="DOI">10.5194/amt-11-6203-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx26"><?xmltex \def\ref@label{{\v{S}auliene et~al.(2019)\v{S}auliene, \v{S}ukiene, Daunys, Valiulis,
Vaitkevi\v{c}ius, Matavulj, Brdar, Panic, Sikoparija, Clot, Crouzy, and
Sofiev}}?><label>Šauliene et al.(2019)Šauliene, Šukiene, Daunys, Valiulis,
Vaitkevičius, Matavulj, Brdar, Panic, Sikoparija, Clot, Crouzy, and
Sofiev</label><?label sauliene2019?><mixed-citation>Šaulienė, I., Šukienė, L., Daunys, G., Valiulis, G., Vaitkevičius, L., Matavulj, P., Brdar, S., Panic, M., Sikoparija, B., Clot, B., Crouzy, B., and Sofiev, M.: Automatic pollen recognition with the Rapid-E particle counter: the first-level procedure, experience and next steps, Atmos. Meas. Tech., 12, 3435–3452, <ext-link xlink:href="https://doi.org/10.5194/amt-12-3435-2019" ext-link-type="DOI">10.5194/amt-12-3435-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx27"><?xmltex \def\ref@label{{Sauvageat et~al.(2020)Sauvageat, Zeder, Auderset, Calpini, Clot,
Crouzy, Konzelmann, Lieberherr, Tummon, and Vasilatou}}?><label>Sauvageat et al.(2020)Sauvageat, Zeder, Auderset, Calpini, Clot,
Crouzy, Konzelmann, Lieberherr, Tummon, and Vasilatou</label><?label sauvageat2020real?><mixed-citation>Sauvageat, E., Zeder, Y., Auderset, K., Calpini, B., Clot, B., Crouzy, B., Konzelmann, T., Lieberherr, G., Tummon, F., and Vasilatou, K.: Real-time pollen monitoring using digital holography, Atmos. Meas. Tech., 13, 1539–1550, <ext-link xlink:href="https://doi.org/10.5194/amt-13-1539-2020" ext-link-type="DOI">10.5194/amt-13-1539-2020</ext-link>, 2020.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx28"><?xmltex \def\ref@label{{Savage et~al.({2017})Savage, Krentz, Koenemann, Han, Mainelis,
Poehlker, and Huffman}}?><label>Savage et al.(2017)Savage, Krentz, Koenemann, Han, Mainelis,
Poehlker, and Huffman</label><?label intro5?><mixed-citation>Savage, N. J., Krentz, C. E., Könemann, T., Han, T. T., Mainelis, G., Pöhlker, C., and Huffman, J. A.: Systematic characterization and fluorescence threshold strategies for the wideband integrated bioaerosol sensor (WIBS) using size-resolved biological and interfering particles, Atmos. Meas. Tech., 10, 4279–4302, <ext-link xlink:href="https://doi.org/10.5194/amt-10-4279-2017" ext-link-type="DOI">10.5194/amt-10-4279-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx29"><?xmltex \def\ref@label{{Te{\v{s}}endi{\'{c}} et~al.(2020)Te{\v{s}}endi{\'{c}},
Boberi{\'{c}}~Krsti{\'{c}}ev, Matavulj, Brdar, Pani{\'{c}}, Mini{\'{c}}, and
{\v{S}}ikoparija}}?><label>Tešendić et al.(2020)Tešendić,
Boberić Krstićev, Matavulj, Brdar, Panić, Minić, and
Šikoparija</label><?label tevsendic2020realforall?><mixed-citation>Tešendić, D., Boberić Krstićev, D., Matavulj, P., Brdar, S.,
Panić, M., Minić, V., and Šikoparija, B.: RealForAll: real-time
system for automatic detection of airborne pollen, Enterprise Information
Systems, Taylor &amp; Francis, 1–17,  <ext-link xlink:href="https://doi.org/10.1080/17517575.2020.1793391" ext-link-type="DOI">10.1080/17517575.2020.1793391</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx30"><?xmltex \def\ref@label{{Vasilatou et~al.(2021)Vasilatou, Wälchli, Koust, Horender, Iida,
Sakurai, Schneider, Spielvogel, Wu, and Auderset}}?><label>Vasilatou et al.(2021)Vasilatou, Wälchli, Koust, Horender, Iida,
Sakurai, Schneider, Spielvogel, Wu, and Auderset</label><?label VASILATOU2021105818?><mixed-citation>Vasilatou, K., Wälchli, C., Koust, S., Horender, S., Iida, K., Sakurai, H.,
Schneider, F., Spielvogel, J., Wu, T. Y., and Auderset, K.: Calibration of
optical particle size spectrometers against a primary standard: Counting
efficiency profile of the TSI Model 3330 OPS and Grimm 11-D monitor in the
particle size range from 300 nm to 10 <inline-formula><mml:math id="M307" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m, J. Aerosol Sci., 157,
105818, <ext-link xlink:href="https://doi.org/10.1016/j.jaerosci.2021.105818" ext-link-type="DOI">10.1016/j.jaerosci.2021.105818</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx31"><?xmltex \def\ref@label{{W{\"{u}}thrich et~al.(1995)W{\"{u}}thrich, Schindler, Leuenberger, and
Ackermann-Liebrich}}?><label>Wüthrich et al.(1995)Wüthrich, Schindler, Leuenberger, and
Ackermann-Liebrich</label><?label swiss?><mixed-citation>
Wüthrich, B., Schindler, C., Leuenberger, P., and Ackermann-Liebrich, U.:
Prevalence of atopy and pollinosis in the adult population of Switzerland
(SAPALDIA study), Int. Arch. Allergy  Imm., 106,
149–156, 1995.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Assessment of real-time bioaerosol particle counters using reference chamber experiments</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Buters et al.(2018)Buters, Antunes, Galveias, Bergmann, Thibaudon,
Galán et al.</label><mixed-citation>
Buters, J., Antunes, C., Galveias, A., Bergmann, K., Thibaudon, M., Galán,
C., Galán, C., Schmidt Weber, C., and Oteros, J.: Pollen and spore monitoring in the world, Clin.
Transl. Allergy, 8, <a href="https://doi.org/10.1186/s13601-018-0197-8" target="_blank">https://doi.org/10.1186/s13601-018-0197-8</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Calvo et al.(2018)Calvo, Baumgardner, Castro, Fernández-González,
Vega-Maray, Valencia-Barrera, Oduber, Blanco-Alegre, and Fraile</label><mixed-citation>
Calvo, A., Baumgardner, D., Castro, A., Fernández-González, D., Vega-Maray,
A., Valencia-Barrera, R., Oduber, F., Blanco-Alegre, C., and Fraile, R.:
Daily behavior of urban Fluorescing Aerosol Particles in northwest Spain,
Atmos. Environ., 184, 262–277,
<a href="https://doi.org/10.1016/j.atmosenv.2018.04.027" target="_blank">https://doi.org/10.1016/j.atmosenv.2018.04.027</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Chappuis et al.(2019)Chappuis, Tummon, Clot, Konzelmann, Calpini, and
Crouzy</label><mixed-citation>
Chappuis, C., Tummon, F., Clot, B., Konzelmann, T., Calpini, B., and Crouzy,
B.: Automatic pollen monitoring: first insights from hourly data,
Aerobiologia, 36, 159–170, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Crouzy et al.(2016)Crouzy, M., Konzelmann, Calpini, and
Clot</label><mixed-citation>
Crouzy, B., M., S., Konzelmann, T., Calpini, B., and Clot, B.: All-optical
automatic pollen indentification: Towards an operational system, Atmos.
Environ., 140, 202–212, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>D'Amato et al.(2007)D'Amato, Cecchi, Bonini, Nunes, Annesi-Maesano,
Behrendt, Liccardi, Popov, and Van Cauwenberge</label><mixed-citation>
D'Amato, G., Cecchi, L., Bonini, S., Nunes, C., Annesi-Maesano, I., Behrendt,
H., Liccardi, G., Popov, T., and Van Cauwenberge, P.: Allergenic pollen and
pollen allergy in Europe, Allergy, 62, 976–990,
<a href="https://doi.org/10.1111/j.1398-9995.2007.01393.x" target="_blank">https://doi.org/10.1111/j.1398-9995.2007.01393.x</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Foot et al.(2008)Foot, Kaye, Stanley, Barrington, Gallagher, and
Gabey</label><mixed-citation>
Foot, V. E., Kaye, P. H., Stanley, W. R., Barrington, S. J., Gallagher, M., and
Gabey, A.: Low-cost real-time multiparameter bio-aerosol sensors, in:
Optically Based Biological and Chemical Detection for Defence IV,International Society for Optics and Photonics, vol. 7116,
p. 71160I, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Forde et al.(2019)Forde, Gallagher, Walker, Foot, Attwood, Granger,
Sarda-Estève, Stanley, Kaye, and Topping</label><mixed-citation>
Forde, E., Gallagher, M., Walker, M., Foot, V., Attwood, A., Granger, G.,
Sarda-Estève, R., Stanley, W., Kaye, P., and Topping, D.: Intercomparison of
Multiple UV-LIF Spectrometers Using the Aerosol Challenge Simulator,
Atmosphere, 10, 797, <a href="https://doi.org/10.3390/atmos10120797" target="_blank">https://doi.org/10.3390/atmos10120797</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Gabey et al.(2010)Gabey, Gallagher, Whitehead, Dorsey, Kaye, and
Stanley</label><mixed-citation>
Gabey, A. M., Gallagher, M. W., Whitehead, J., Dorsey, J. R., Kaye, P. H., and Stanley, W. R.: Measurements and comparison of primary biological aerosol above and below a tropical forest canopy using a dual channel fluorescence spectrometer, Atmos. Chem. Phys., 10, 4453–4466, <a href="https://doi.org/10.5194/acp-10-4453-2010" target="_blank">https://doi.org/10.5194/acp-10-4453-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Galán et al.(2014)Galán, Smith, Thibaudon, Frenguelli, Oteros,
Gehrig, Berger, Clot, and Brandao</label><mixed-citation>
Galán, C., Smith, M., Thibaudon, M., Frenguelli, G., Oteros, J., Gehrig, R.,
Berger, U., Clot, B., and Brandao, R.: Pollen monitoring: minimum
requirements and reproducibility of analysis, Aerobiologia, 30, 385–395,
<a href="https://doi.org/10.1007/s10453-014-9335-5" target="_blank">https://doi.org/10.1007/s10453-014-9335-5</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Healy et al.(2012)Healy, O’Connor, and
Sodeau</label><mixed-citation>
Healy, D. A., O’Connor, D. J., and Sodeau, J. R.: Measurement of the particle
counting efficiency of the “Waveband Integrated Bioaerosol Sensor” model
number 4 (WIBS-4), J. Aerosol Scie., 47, 94–99, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Hernandez et al.(2016)Hernandez, Perring, McCabe, Kok, Granger, and
Baumgardner</label><mixed-citation>
Hernandez, M., Perring, A. E., McCabe, K., Kok, G., Granger, G., and Baumgardner, D.: Chamber catalogues of optical and fluorescent signatures distinguish bioaerosol classes, Atmos. Meas. Tech., 9, 3283–3292, <a href="https://doi.org/10.5194/amt-9-3283-2016" target="_blank">https://doi.org/10.5194/amt-9-3283-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Hirst(1952)</label><mixed-citation>
Hirst, J. M.: An automatic volumetric spore trap, Ann. Appl. Biol.,
39, 257–265, <a href="https://doi.org/10.1111/j.1744-7348.1952.tb00904.x" target="_blank">https://doi.org/10.1111/j.1744-7348.1952.tb00904.x</a>, 1952.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Horender et al.(2019)Horender, Auderset, and Vasilatou</label><mixed-citation>
Horender, S., Auderset, K., and Vasilatou, K.: Facility for calibration of
optical and condensation particle counters based on a turbulent aerosol
mixing tube and a reference optical particle counter, Rev. Sci.
Instrum., 90, 075111, <a href="https://doi.org/10.1063/1.5095853" target="_blank">https://doi.org/10.1063/1.5095853</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Huffman et al.(2019)Huffman, Perring, Savage, Clot, Crouzy, Tummon,
Shoshanim, Damit, Schneider, Sivaprakasam, Zawadowicz, Crawford, Gallagher,
Topping, Doughty, Hill, and Pan</label><mixed-citation>
Huffman, J. A., Perring, A. E., Savage, N. J., Clot, B., Crouzy, B., Tummon,
F., Shoshanim, O., Damit, B., Schneider, J., Sivaprakasam, V., Zawadowicz,
M. A., Crawford, I., Gallagher, M., Topping, D., Doughty, D. C., Hill, S. C.,
and Pan, Y.: Real-time sensing of bioaerosols: Review and current
perspectives, Aerosol Sci. Tech., 54, 465–495,
<a href="https://doi.org/10.1080/02786826.2019.1664724" target="_blank">https://doi.org/10.1080/02786826.2019.1664724</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Hughes et al.(2020)Hughes, Mampage, Jones, Liu, and
Stone</label><mixed-citation>
Hughes, D. D., Mampage, C. B. A., Jones, L. M., Liu, Z., and Stone, E. A.:
Characterization of Atmospheric Pollen Fragments during Springtime
Thunderstorms, Environ. Sci. Tech. Let., 7, 409–414,
<a href="https://doi.org/10.1021/acs.estlett.0c00213" target="_blank">https://doi.org/10.1021/acs.estlett.0c00213</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Jaeger(2006)</label><mixed-citation>
Jaeger, S.: The trouble with threshold values for allergy forecasts,
Aerobiological Monographs, Towards a comprehensive vision, edited by: Clot,
B., Comtois, P., and Escamilla-Garcia, B., MeteoSwiss (CH) and University of Montreal (CA), 233–245, ISBN: 978-2-8399-0466-7, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Kiselev et al.(2013)Kiselev, Bonacina, and Wolf</label><mixed-citation>
Kiselev, D., Bonacina, L., and Wolf, J.-P.: A flash-lamp based device for
fluorescence detection and identification of individual pollen grains, Rev. Sci. Instrum., 84, 033302,
<a href="https://doi.org/10.1063/1.4793792" target="_blank">https://doi.org/10.1063/1.4793792</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Könemann et al.(2018)Könemann, Savage, Huffman, and
Pöhlker</label><mixed-citation>
Könemann, T., Savage, N. J., Huffman, J. A., and Pöhlker, C.: Characterization of steady-state fluorescence properties of polystyrene latex spheres using off- and online spectroscopic methods, Atmos. Meas. Tech., 11, 3987–4003, <a href="https://doi.org/10.5194/amt-11-3987-2018" target="_blank">https://doi.org/10.5194/amt-11-3987-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Könemann et al.(2019)</label><mixed-citation>
Könemann, T., Savage, N., Klimach, T., Walter, D., Fröhlich-Nowoisky, J., Su, H., Pöschl, U., Huffman, J. A., and Pöhlker, C.: Spectral Intensity Bioaerosol Sensor (SIBS): an instrument for spectrally resolved fluorescence detection of single particles in real time, Atmos. Meas. Tech., 12, 1337–1363, <a href="https://doi.org/10.5194/amt-12-1337-2019" target="_blank">https://doi.org/10.5194/amt-12-1337-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Löndahl(2014)</label><mixed-citation>
Löndahl, J.: Physical and Biological Properties of Bioaerosols,
Springer New York, New York, NY, 33–48, <a href="https://doi.org/10.1007/978-1-4419-5582-1_3" target="_blank">https://doi.org/10.1007/978-1-4419-5582-1_3</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>O'Connor et al.(2014)O'Connor, Healy, Hellebust, Buters, and
Sodeau</label><mixed-citation>
O'Connor, D. J., Healy, D. A., Hellebust, S., Buters, J. T. M., and Sodeau,
J. R.: Using the WIBS-4 (Waveband Integrated Bioaerosol Sensor) Technique for
the On-Line Detection of Pollen Grains, Aerosol Sci. Tech., 48, 341–349,
<a href="https://doi.org/10.1080/02786826.2013.872768" target="_blank">https://doi.org/10.1080/02786826.2013.872768</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Perring et al.(2015a)Perring, Schwarz, Baumgardner,
Hernandez, Spracklen, Heald, Gao, Kok, McMeeking, McQuaid, and Fahey</label><mixed-citation>
Perring, A. E., Schwarz, J. P., Baumgardner, D., Hernandez, M. T., Spracklen,
D. V., Heald, C. L., Gao, R. S., Kok, G., McMeeking, G. R., McQuaid, J. B.,
and Fahey, D. W.: Airborne observations of regional variation in fluorescent
aerosol across the United States, J. Geophys. Res.-Atmos., 120, 1153–1170, <a href="https://doi.org/10.1002/2014JD022495" target="_blank">https://doi.org/10.1002/2014JD022495</a>,
2015a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Perring et al.(2015b)Perring, Schwarz, Baumgardner,
Hernandez, Spracklen, Heald, Gao, Kok, McMeeking, McQuaid, and
Fahey</label><mixed-citation>
Perring, A. E., Schwarz, J. P., Baumgardner, D., Hernandez, M. T., Spracklen,
D. V., Heald, C. L., Gao, R. S., Kok, G., McMeeking, G. R., McQuaid, J. B.,
and Fahey, D. W.: Airborne observations of regional variation in fluorescent
aerosol across the United States, J. Geophys. Res.-Atmos., 120, 1153–1170, <a href="https://doi.org/10.1002/2014JD022495" target="_blank">https://doi.org/10.1002/2014JD022495</a>,
2015b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Ring et al.(2001)Ring, Krämer, Schäfer, and Behrent</label><mixed-citation>
Ring, J., Krämer, U., Schäfer, T., and Behrent, H.: Why are allergies
increasing?, Curr. Opin. Immunol., 13, 701–708,
<a href="https://doi.org/10.1016/S0952-7915(01)00282-5" target="_blank">https://doi.org/10.1016/S0952-7915(01)00282-5</a>, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Ruske et al.(2018)Ruske, Topping, Foot, Morse, and
Gallagher</label><mixed-citation>
Ruske, S., Topping, D. O., Foot, V. E., Morse, A. P., and Gallagher, M. W.: Machine learning for improved data analysis of biological aerosol using the WIBS, Atmos. Meas. Tech., 11, 6203–6230, <a href="https://doi.org/10.5194/amt-11-6203-2018" target="_blank">https://doi.org/10.5194/amt-11-6203-2018</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Šauliene et al.(2019)Šauliene, Šukiene, Daunys, Valiulis,
Vaitkevičius, Matavulj, Brdar, Panic, Sikoparija, Clot, Crouzy, and
Sofiev</label><mixed-citation>
Šaulienė, I., Šukienė, L., Daunys, G., Valiulis, G., Vaitkevičius, L., Matavulj, P., Brdar, S., Panic, M., Sikoparija, B., Clot, B., Crouzy, B., and Sofiev, M.: Automatic pollen recognition with the Rapid-E particle counter: the first-level procedure, experience and next steps, Atmos. Meas. Tech., 12, 3435–3452, <a href="https://doi.org/10.5194/amt-12-3435-2019" target="_blank">https://doi.org/10.5194/amt-12-3435-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Sauvageat et al.(2020)Sauvageat, Zeder, Auderset, Calpini, Clot,
Crouzy, Konzelmann, Lieberherr, Tummon, and Vasilatou</label><mixed-citation>
Sauvageat, E., Zeder, Y., Auderset, K., Calpini, B., Clot, B., Crouzy, B., Konzelmann, T., Lieberherr, G., Tummon, F., and Vasilatou, K.: Real-time pollen monitoring using digital holography, Atmos. Meas. Tech., 13, 1539–1550, <a href="https://doi.org/10.5194/amt-13-1539-2020" target="_blank">https://doi.org/10.5194/amt-13-1539-2020</a>, 2020.

</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Savage et al.(2017)Savage, Krentz, Koenemann, Han, Mainelis,
Poehlker, and Huffman</label><mixed-citation>
Savage, N. J., Krentz, C. E., Könemann, T., Han, T. T., Mainelis, G., Pöhlker, C., and Huffman, J. A.: Systematic characterization and fluorescence threshold strategies for the wideband integrated bioaerosol sensor (WIBS) using size-resolved biological and interfering particles, Atmos. Meas. Tech., 10, 4279–4302, <a href="https://doi.org/10.5194/amt-10-4279-2017" target="_blank">https://doi.org/10.5194/amt-10-4279-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Tešendić et al.(2020)Tešendić,
Boberić Krstićev, Matavulj, Brdar, Panić, Minić, and
Šikoparija</label><mixed-citation>
Tešendić, D., Boberić Krstićev, D., Matavulj, P., Brdar, S.,
Panić, M., Minić, V., and Šikoparija, B.: RealForAll: real-time
system for automatic detection of airborne pollen, Enterprise Information
Systems, Taylor &amp; Francis, 1–17,  <a href="https://doi.org/10.1080/17517575.2020.1793391" target="_blank">https://doi.org/10.1080/17517575.2020.1793391</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Vasilatou et al.(2021)Vasilatou, Wälchli, Koust, Horender, Iida,
Sakurai, Schneider, Spielvogel, Wu, and Auderset</label><mixed-citation>
Vasilatou, K., Wälchli, C., Koust, S., Horender, S., Iida, K., Sakurai, H.,
Schneider, F., Spielvogel, J., Wu, T. Y., and Auderset, K.: Calibration of
optical particle size spectrometers against a primary standard: Counting
efficiency profile of the TSI Model 3330 OPS and Grimm 11-D monitor in the
particle size range from 300&thinsp;nm to 10&thinsp;µm, J. Aerosol Sci., 157,
105818, <a href="https://doi.org/10.1016/j.jaerosci.2021.105818" target="_blank">https://doi.org/10.1016/j.jaerosci.2021.105818</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Wüthrich et al.(1995)Wüthrich, Schindler, Leuenberger, and
Ackermann-Liebrich</label><mixed-citation>
Wüthrich, B., Schindler, C., Leuenberger, P., and Ackermann-Liebrich, U.:
Prevalence of atopy and pollinosis in the adult population of Switzerland
(SAPALDIA study), Int. Arch. Allergy  Imm., 106,
149–156, 1995.
</mixed-citation></ref-html>--></article>