<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article"><?xmltex \makeatother\@nolinetrue\makeatletter?>
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-15-2433-2022</article-id><title-group><article-title>Improved calibration procedures for the EM27/SUN<?xmltex \hack{\break}?> spectrometers of the COllaborative Carbon Column<?xmltex \hack{\break}?> Observing Network (COCCON)</article-title><alt-title>Upgrade of calibration procedures for EM27/SUN spectrometers</alt-title>
      </title-group><?xmltex \runningtitle{Upgrade of calibration procedures for EM27/SUN spectrometers}?><?xmltex \runningauthor{C.~Alberti et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Alberti</surname><given-names>Carlos</given-names></name>
          <email>carlos.alberti@kit.edu</email>
        <ext-link>https://orcid.org/0000-0002-1574-5393</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Hase</surname><given-names>Frank</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Frey</surname><given-names>Matthias</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-0664-6817</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Dubravica</surname><given-names>Darko</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Blumenstock</surname><given-names>Thomas</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-4005-900X</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Dehn</surname><given-names>Angelika</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Castracane</surname><given-names>Paolo</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Surawicz</surname><given-names>Gregor</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Harig</surname><given-names>Roland</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5 aff6">
          <name><surname>Baier</surname><given-names>Bianca C.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Bès</surname><given-names>Caroline</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff8">
          <name><surname>Bi</surname><given-names>Jianrong</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff9">
          <name><surname>Boesch</surname><given-names>Hartmut</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff10">
          <name><surname>Butz</surname><given-names>André</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-0593-1608</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff11">
          <name><surname>Cai</surname><given-names>Zhaonan</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff12">
          <name><surname>Chen</surname><given-names>Jia</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6350-6610</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff13">
          <name><surname>Crowell</surname><given-names>Sean M.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-8353-3707</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff14">
          <name><surname>Deutscher</surname><given-names>Nicholas M.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-2906-2577</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff15">
          <name><surname>Ene</surname><given-names>Dragos</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-5266-0930</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff16">
          <name><surname>Franklin</surname><given-names>Jonathan E.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff17">
          <name><surname>García</surname><given-names>Omaira</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-8395-6440</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff14">
          <name><surname>Griffith</surname><given-names>David</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-7986-1924</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff18">
          <name><surname>Grouiez</surname><given-names>Bruno</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff19">
          <name><surname>Grutter</surname><given-names>Michel</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9800-5878</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff18">
          <name><surname>Hamdouni</surname><given-names>Abdelhamid</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff20 aff21">
          <name><surname>Houweling</surname><given-names>Sander</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6189-1009</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff9">
          <name><surname>Humpage</surname><given-names>Neil</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1109-2524</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff22 aff23">
          <name><surname>Jacobs</surname><given-names>Nicole</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff24">
          <name><surname>Jeong</surname><given-names>Sujong</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-4586-4534</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff18">
          <name><surname>Joly</surname><given-names>Lilian</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff14">
          <name><surname>Jones</surname><given-names>Nicholas B.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Jouglet</surname><given-names>Denis</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff25">
          <name><surname>Kivi</surname><given-names>Rigel</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-8828-2759</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff10">
          <name><surname>Kleinschek</surname><given-names>Ralph</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff26">
          <name><surname>Lopez</surname><given-names>Morgan</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1725-3410</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff27">
          <name><surname>Medeiros</surname><given-names>Diogo J.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Morino</surname><given-names>Isamu</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2720-1569</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff28">
          <name><surname>Mostafavipak</surname><given-names>Nasrin</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Müller</surname><given-names>Astrid</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9500-8475</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Ohyama</surname><given-names>Hirofumi</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2109-9874</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff29 aff30">
          <name><surname>Palmer</surname><given-names>Paul I.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1487-0969</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff31">
          <name><surname>Pathakoti</surname><given-names>Mahesh</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff32">
          <name><surname>Pollard</surname><given-names>David F.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9923-2984</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff33">
          <name><surname>Raffalski</surname><given-names>Uwe</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9038-0227</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff26">
          <name><surname>Ramonet</surname><given-names>Michel</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1157-1186</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff34">
          <name><surname>Ramsay</surname><given-names>Robbie</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3121-2562</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff35">
          <name><surname>Sha</surname><given-names>Mahesh Kumar</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1440-1529</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff36">
          <name><surname>Shiomi</surname><given-names>Kei</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1206-8614</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff22">
          <name><surname>Simpson</surname><given-names>William</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-8596-7290</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff19">
          <name><surname>Stremme</surname><given-names>Wolfgang</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-0791-3833</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff37">
          <name><surname>Sun</surname><given-names>Youwen</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3126-3252</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Tanimoto</surname><given-names>Hiroshi</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-5424-9923</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff38">
          <name><surname>Té</surname><given-names>Yao</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-6405-8074</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff39">
          <name><surname>Tsidu</surname><given-names>Gizaw Mengistu</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3076-4696</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff14">
          <name><surname>Velazco</surname><given-names>Voltaire A.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1376-438X</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff40">
          <name><surname>Vogel</surname><given-names>Felix</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-2548-3390</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff41">
          <name><surname>Watanabe</surname><given-names>Masataka</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff42">
          <name><surname>Wei</surname><given-names>Chong</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-0632-4324</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff28">
          <name><surname>Wunch</surname><given-names>Debra</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-4924-0377</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff27">
          <name><surname>Yamasoe</surname><given-names>Marcia</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3066-9146</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff43">
          <name><surname>Zhang</surname><given-names>Lu</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff44">
          <name><surname>Orphal</surname><given-names>Johannes</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Institute of Meteorology and Climate Research (IMK-ASF), Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>National Institute for Environmental Studies (NIES), Tsukuba, Japan</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>European Space Agency/Centre for Earth Observation (ESA/ESRIN),  Frascati, Italy</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Bruker Optics GmbH, Ettlingen, Germany</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>Cooperative Institute for Research in Environmental Sciences  (CIRES),<?xmltex \hack{\break}?> University of Colorado-Boulder, Boulder, CO, USA</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Earth System Research Laboratory Global Monitoring Division, National Oceanic and Atmospheric Administration(NOAA), Boulder, CO, USA</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>Centre National d'Etudes Spatiales (CNES), Paris, France​​​​​​​</institution>
        </aff>
        <aff id="aff8"><label>8</label><institution>Key Laboratory for Semi-Arid Climate Change of the Ministry of Education,<?xmltex \hack{\break}?> College of Atmospheric Sciences, Lanzhou University, Lanzhou, China​​​​​​​</institution>
        </aff>
        <aff id="aff9"><label>9</label><institution>National Centre for Earth Observation, University of Leicester, Leicester, UK</institution>
        </aff>
        <aff id="aff10"><label>10</label><institution>Institut für Umweltphysik, Universität Heidelberg, Heidelberg, Germany</institution>
        </aff>
        <aff id="aff11"><label>11</label><institution>Carbon Neutrality Research Center, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing, China</institution>
        </aff>
        <aff id="aff12"><label>12</label><institution>Environmental Sensing and Modeling, Department of Electrical and Computer Engineering,<?xmltex \hack{\break}?> Technische Universität München, Munich, Germany</institution>
        </aff>
        <aff id="aff13"><label>13</label><institution>College of Atmospheric and Geographic Sciences, University of Oklahoma, Norman, OK, USA</institution>
        </aff>
        <aff id="aff14"><label>14</label><institution>Centre for Atmospheric Chemistry, University of Wollongong, Wollongong, NSW, Australia​​​​​​​</institution>
        </aff>
        <aff id="aff15"><label>15</label><institution>National Institute of R&amp;D for Optoelectronics INOE 2000, Măgurele, Ilfov, Romania</institution>
        </aff>
        <aff id="aff16"><label>16</label><institution>School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA</institution>
        </aff>
        <aff id="aff17"><label>17</label><institution>Izaña Atmospheric Research Centre (IARC), State Meteorological Agency of Spain (AEMet), Santa Cruz de Tenerife, Spain</institution>
        </aff>
        <aff id="aff18"><label>18</label><institution>Groupe de Spectrométrie Moléculaire et Atmosphérique (GSMA), Université de Reims-Champagne Ardenne,<?xmltex \hack{\break}?> UMR CNRS 7331, Moulin de la Housse, BP 1039, 51687 CEDEX 2 Reims, France</institution>
        </aff>
        <aff id="aff19"><label>19</label><institution>Centro de Ciencias de la Atmósfera, Universidad Nacional Autónoma de México, Mexico City, Mexico</institution>
        </aff>
        <aff id="aff20"><label>20</label><institution>SRON Netherlands Institute for Space Research, Utrecht, the Netherlands</institution>
        </aff>
        <aff id="aff21"><label>21</label><institution>Department of Earth Sciences, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands</institution>
        </aff>
        <aff id="aff22"><label>22</label><institution>Department of Chemistry and the Geophysical Institute, University of Alaska Fairbanks, Fairbanks, AK, USA</institution>
        </aff>
        <aff id="aff23"><label>23</label><institution>Cooperative Institute for Research in the Atmosphere (CIRA), Colorado State University, Fort Collins, CO, USA</institution>
        </aff>
        <aff id="aff24"><label>24</label><institution>Department of Environmental Planning, Graduate School of Environmental Studies,<?xmltex \hack{\break}?> Seoul National University, Seoul, Republic of Korea</institution>
        </aff>
        <aff id="aff25"><label>25</label><institution>Space and Earth Observation Centre, Finnish Meteorological Institute, Sodankylä, Finland</institution>
        </aff>
        <aff id="aff26"><label>26</label><institution>Université Paris-Saclay, CEA, CNRS, UVSQ, Laboratoire des Sciences du Climat et de l'Environnement (LSCE/IPSL), Gif-sur-Yvette, France</institution>
        </aff>
        <aff id="aff27"><label>27</label><institution>Departamento de Ciências Atmosféricas, Instituto de Astronomia, Geofísica e Ciências Atmosféricas,<?xmltex \hack{\break}?> Universidade de São Paulo, São Paulo, Brazil</institution>
        </aff>
        <aff id="aff28"><label>28</label><institution>Department of Physics, University of Toronto, Toronto, Canada</institution>
        </aff>
        <aff id="aff29"><label>29</label><institution>School of GeoSciences, University of Edinburgh, Edinburgh, UK</institution>
        </aff>
        <aff id="aff30"><label>30</label><institution>National Centre for Earth Observation, University of Edinburgh, Edinburgh, UK</institution>
        </aff>
        <aff id="aff31"><label>31</label><institution>Earth and Climate Sciences Area (ECSA), National Remote Sensing Centre (NRSC), ISRO, Hyderabad, India</institution>
        </aff>
        <aff id="aff32"><label>32</label><institution>National Institute of Water and Atmospheric Research Ltd (NIWA), Lauder, New Zealand</institution>
        </aff>
        <aff id="aff33"><label>33</label><institution>Swedish Institute of Space Physics, Kiruna, Sweden</institution>
        </aff>
        <aff id="aff34"><label>34</label><institution>NERC Field Spectroscopy Facility, James Hutton Road, Edinburgh, EH9 3FE, UK</institution>
        </aff>
        <aff id="aff35"><label>35</label><institution>Royal Belgian Institute for Space Aeronomy (BIRA-IASB), Brussels, Belgium</institution>
        </aff>
        <aff id="aff36"><label>36</label><institution>Earth Observation Research Center, Japan Aerospace Exploration Agency (JAXA), Tsukuba, Ibaraki, Japan</institution>
        </aff>
        <aff id="aff37"><label>37</label><institution>Anhui Institute of Optics and Fine Mechanics, HFIPS, Chinese Academy of Sciences, Hefei, China</institution>
        </aff>
        <aff id="aff38"><label>38</label><institution>Laboratoire d'Etudes du Rayonnement et de la Matière en Astrophysique et Atmosphères (LERMA-IPSL),<?xmltex \hack{\break}?> Sorbonne Université, Paris, France</institution>
        </aff>
        <aff id="aff39"><label>39</label><institution>Department of Earth and Environmental Sciences, Botswana International University of Science and Technology,<?xmltex \hack{\break}?> Palapye, Botswana​​​​​​​</institution>
        </aff>
        <aff id="aff40"><label>40</label><institution>Climate Research Division, Environment and Climate Change Canada, Toronto, Canada</institution>
        </aff>
        <aff id="aff41"><label>41</label><institution>Research and Development Initiative, Chuo University, Bunkyo-ku, Tokyo, Japan</institution>
        </aff>
        <aff id="aff42"><label>42</label><institution>Shanghai Carbon Data Research Center, Shanghai Advanced Research Institute (SARI),<?xmltex \hack{\break}?> Chinese Academy of Sciences, Shanghai, China</institution>
        </aff>
        <aff id="aff43"><label>43</label><institution>National Satellite Meteorological Center (NSMC), China Meteorological Administration, Beijing, China</institution>
        </aff>
        <aff id="aff44"><label>a</label><institution>now at: Division 4 “Natural and Built Environment”, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Carlos Alberti (carlos.alberti@kit.edu)</corresp></author-notes><pub-date><day>22</day><month>April</month><year>2022</year></pub-date>
      
      <volume>15</volume>
      <issue>8</issue>
      <fpage>2433</fpage><lpage>2463</lpage>
      <history>
        <date date-type="received"><day>21</day><month>November</month><year>2021</year></date>
           <date date-type="accepted"><day>28</day><month>March</month><year>2022</year></date>
           <date date-type="rev-recd"><day>20</day><month>March</month><year>2022</year></date>
           <date date-type="rev-request"><day>9</day><month>December</month><year>2021</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2022 Carlos Alberti et al.</copyright-statement>
        <copyright-year>2022</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022.html">This article is available from https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d1e966">In this study, an extension on the previously reported status of the
COllaborative Carbon Column Observing Network's (COCCON) calibration
procedures incorporating refined methods is presented. COCCON is a global
network of portable Bruker EM27/SUN FTIR spectrometers for deriving
column-averaged atmospheric abundances of greenhouse gases. The original
laboratory open-path lamp measurements for deriving the instrumental line
shape (ILS) of the spectrometer from water vapour lines have been refined
and extended to the secondary detector channel incorporated in the EM27/SUN
spectrometer for detection of carbon monoxide (CO). The refinements
encompass improved spectroscopic line lists for the relevant water lines and
a revision of the laboratory pressure measurements used for the analysis of
the spectra. The new results are found to be in good agreement with those
reported by Frey et al. (2019) and discussed in detail. In addition, a new
calibration cell for ILS measurements was designed, constructed and put into
service. Spectrometers calibrated since January 2020 were tested using both
methods for ILS characterization, open-path (OP) and cell measurements. We
demonstrate that both methods can detect the small variations in ILS
characteristics between different spectrometers, but the results of the cell
method indicate a systematic bias of the OP method. Finally, a revision and
extension of the COCCON network instrument-to-instrument calibration factors
for <inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO and <inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is presented, incorporating 47 new
spectrometers (of 83 in total by now). This calibration is based on the
reference EM27/SUN spectrometer operated by the Karlsruhe Institute of
Technology (KIT) and spectra collected by the collocated TCCON station
Karlsruhe. Variations in the instrumental characteristics of the reference
EM27/SUN from 2014 to 2017 were detected, probably arising from realignment
and the dual-channel upgrade performed in early 2018. These variations are
considered in the evaluation of the instrument-specific calibration factors
in order to keep all tabulated calibration results consistent.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e1000">The activities of modern humans have detectable negative impacts on the
atmosphere, including the release of various trace substances into it,
mainly due to industrialization, to the globalization of the economy and
related transport, and to increasing power generation and land use. Among
them, greenhouse gases (GHGs) directly affect the Earth's radiative balance
because they reduce the thermal infrared emission to space. Due to their
long lifetime, those gases affect the climate for decades or centuries. The
reduction of GHG emissions is thus recognized as an important and urgent
political and societal task. Although there are several species categorized
as GHGs, the gases mainly responsible for the increasing global warming are
carbon dioxide (<inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and methane (<inline-formula><mml:math id="M4" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). The anthropogenic
emissions of <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> from fossil fuel combustion are the main driver of
global warming, which will reach and most likely exceed 1.5 <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>
within the next coming 2 decades (IPCC, 2021). Methods for monitoring and quantifying those gases – thereby
pinning down their sources and sinks as well as their links with various
human activities – are essential for appropriate decision-making to mitigate
climate change. In general, atmospheric concentrations of GHGs are
categorized into in situ and remote sensing techniques; the first of these
techniques offers very high accuracy but faces problems due to its high
sensitivity to emitting sources in the vicinity and to details of the
vertical transport. Ground-based remote sensing techniques using solar
absorption spectroscopy deliver column-averaged atmospheric GHG abundances
but suffer from lower precision and accuracy and lower sensitivity for local
sources. These observations are, however, well suited for the validation of
satellite missions and observations of larger source regions. Currently,
several dedicated GHG satellite missions are in orbit: the Greenhouse Gases
Observing Satellite (GOSAT) and GOSAT-2 (Kuze et al., 2009; Morino
et al., 2011; Yoshida et al., 2013; Suto et al., 2021), the Orbiting Carbon
Observatory-2 (OCO-2) and OCO-3 (Frankenberg et al., 2015; Crisp et al.,
2017; Eldering et al., 2017, 2019), the Copernicus Sentinel-5 Precursor
(S5P) (Veefkind et al., 2012), and the Chinese Carbon Dioxide Observation
Satellite (TanSat) (Liu et al., 2018). The ground-based Total Carbon Column
Observing Network (TCCON) (Wunch et al., 2011) is the most important source
for reference validation data and has been recently supplemented by the
portable EM27/SUN spectrometers managed by the COllaborative Carbon Column
Observing Network (COCCON, Frey et al., 2019). Both networks use
solar-viewing Fourier transform infrared (FTIR) spectrometers. There,
column-averaged atmospheric abundances of GHGs are derived from the observed
near-infrared spectra.</p>
      <p id="d1e1048">The TCCON was established in 2004 to obtain accurate measurements of
column-averaged dry-air mole fractions of <inline-formula><mml:math id="M7" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, CO, <inline-formula><mml:math id="M8" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M9" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> (denoted as Xgas, e.g. <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). The TCCON stations operate high-resolution Fourier transform IFS125HR spectrometers (FTS) manufactured by
Bruker. Nowadays the network has 29 operational sites worldwide (Wunch et
al., 2011). Although these TCCON stations are distributed around the globe,
there are still considerable geographic gaps lacking measurements. The
COCCON network emerged in 2016, based on the low-resolution (0.5 <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)
EM27/SUN FTIR spectrometer developed by KIT in cooperation with Bruker (Gisi
et al., 2012; Hase et al., 2016), which delivers similar precision and
accuracy as TCCON, assuming a careful calibration of each spectrometer.
Several studies have revealed its previously unprecedented high level of
performance and stability (Frey et al., 2015, 2019; Sha et al., 2020). In
addition, the portability of the EM27/SUN spectrometer favours campaign use,
and a series of such campaigns have already successfully been conducted by
various investigators (Hase et al., 2015; Hedelius et al., 2016; Butz et al., 2017; Viatte et al., 2017; Chen et al., 2016, 2020; Kille et al., 2019;
Vogel et al., 2019; Luther et al., 2019; Makarova et al., 2021; Dietrich et al., 2021; Jones et al., 2021).</p>
      <p id="d1e1111">As the number of EM27/SUN spectrometers being deployed across the world
continues to grow, it is essential in order to maintain and further improve
the reliability of the network to keep up with proper quality
assurance/quality control (QC/QA) work and to apply the best available
procedures for instrumental characterization on new units before they go
into operation. In this regard one of the most important parameters that
needs to be specified for a defined FTIR spectrometer prior to the analysis
of its atmospheric measurements is the instrumental line shape (ILS).
Several studies have shown that the real ILS deviates from the ideal one
(e.g. Hase, 2012; Hase et al., 1999; Bernardo and Griffith, 2005), e.g. due to interferometric
misalignment, optical aberrations, or uneven illumination or sensitivity of
the detector element. An out-of-range ILS result points to instrumental
issues which need to be alleviated by realignment or replacement of optical
or mechanical components. A good knowledge of the near-nominal ILS is
imperative for a precise GHG retrieval. Portable spectrometers need to
demonstrate their ability to preserve their ILS characteristics during
transport events and over sufficiently long periods of time. Stable
instrumental characteristics have been demonstrated despite harsh transport
and conditions of operation for periods of up to several years (Frey et al.,
2015).</p>
      <p id="d1e1114">The impacts of various error sources on retrieved gas columns and Xgas
results have been discussed in detail by Tu (2019). The error propagation
of the ILS uncertainty into retrieved gas columns and Xgas results is
dominated by the modulation efficiency amplitude (MEA) parameter, which
describes the deviation of the ILS width from the nominal value. We show the
resulting error propagation for an assumed <inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula> %
error in MEA on the columns and Xgas results in
Fig. 1 (similar to Fig. 3.7 presented by Tu,
2019, but covering a somewhat wider SZA range).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e1130">Variation in the relative difference for dry-air gas and total
column gas amounts as a function of solar zenith angle (SZA), for changes in
the original ILS of <inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula> % of the original ILS
parameters for COCCON's reference unit SN37 on 31 May 2021 at Karlsruhe,
Germany, for carbon dioxide, methane and carbon monoxide, respectively, and
the total column amount for oxygen.</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f01.png"/>

      </fig>

      <p id="d1e1149">As can be seen from the Fig. 1, a 0.5 % MEA increase introduces an
<inline-formula><mml:math id="M14" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> decrease on the order of 0.025 %, while for <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> the
opposite behaviour is observed. <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> shows an increase of
<inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula> % with a very low SZA dependency. In the case of XCO, the
resulting disturbance shows a zero crossing near 40<inline-formula><mml:math id="M18" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> SZA and
reaches a maximum value of <inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula> % change at the highest SZA.</p>
      <p id="d1e1215">In this paper, the open-path (OP) method for ILS calculation of EM27/SUN
spectrometers as described by Frey et al. (2015) is significantly improved
and applied to further spectrometers. Additionally, a new calibration cell
filled with <inline-formula><mml:math id="M20" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> was designed, built and used in addition to the
open-path method since January 2020. The OP improvements are described in
Sect. 2.2; the cell method is described in
Sect. 3. This provides additional redundancy of the ILS characterization
and allows the comparison of both approaches, OP and cell measurement. The
results achieved with the OP and cell methods are described and compared in
Sects. 4 and 5, respectively. We confirm that both methods have the
ability to detect residual instrument-specific deviations from the nominal
ILS. The cell method suggests that there is a bias in the open-path results,
probably generated by incorrect pressure broadening parameters of the
relevant <inline-formula><mml:math id="M21" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> lines. Section 6 is devoted to the discussion of the solar
side-by-side measurements. In Sect. 6.1, we
present the continued long-term trace gas measurements of the reference
EM27/SUN spectrometer used as a fixed point for the instrument-specific gas
calibration factors of the other EM27/SUN units. This time series now spans
7 years. We compare these atmospheric measurements with the trace gas
amounts derived from low-resolution spectra collected with the co-located
125HR spectrometer of the Karlsruhe TCCON station. Variations in the
reference unit's instrumental characteristics connected to realignment and
the dual-channel upgrade performed in early 2018 have been identified. In
Sect. 6.2 we show the results from the
re-evaluation of the open-path measurements and list the instrument-specific
calibration factors for each spectrometer, considering the detected
variations in the reference unit. The resulting survey of instrumental
characteristics is a considerable extension of the work by Frey et al. (2019), as it contains results for 47 new spectrometers. In Sect. 6.3, the
spectral signal-to-noise ratio characteristics for all investigated spectrometers
are summarized. Finally, in Sect. 6.4, the effect of the refined
calibration procedure on the consistency of the <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration is
investigated.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Advancing the open-path method for ILS characterization</title>
      <p id="d1e1266">The method described in Frey et al. (2015), of characterizing the ILS of
low-resolution spectrometers using open-path measurements, is improved and
extended; the method is briefly summarized here along with a description of
the main improvements. The idea of the approach is to use the absorption of
infrared radiation from an external tungsten lamp by strong water vapour
lines along a laboratory path of a few metres. A fit to the spectrum is
performed by adjusting the <inline-formula><mml:math id="M23" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> column, a spectral scaling factor, a
spectrally variable background transmission level and a parameterized ILS.
Two parameters are used for describing deviations from the nominal ILS
shape: the “modulation efficiency amplitude” (MEA) describes a deviation
from the expected ILS width, and the “phase error” (PE) quantifies the
asymmetry of the ILS (Hase et al., 1999). Because the widths of the spectral
lines generated along the open path depend on pressure and temperature,
these parameters need to be recorded for the analysis of the measurements.
The self-broadening of <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> is a non-negligible contribution; therefore,
the absorption path length needs to be known. The <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> partial pressure
is calculated from the retrieved <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> column amount, pressure and
temperature, so the analysis of the spectrum is an iterative procedure
(repeated until convergence to a self-consistent solution is reached).</p>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Procedure and set-up</title>
      <p id="d1e1328">The general set-up is described by Gisi et al. (2012) and Frey et al. (2015)
and illustrated in Fig. 2. At least 2 h
before the first interferograms are collected, the spectrometer is powered
up. Two openings in the spectrometer's shelter are uncovered for allowing
exchange between the air trapped inside the spectrometer and the external
laboratory air. This equilibrates the water vapour mixing ratio inside the
spectrometer with the environment and allows the spectrometer to reach a
stable operating temperature, thereby minimizing spectral drifts of the
He–Ne laser which controls the interferogram sampling. For the radiation
source, a commercial halogen lamp attached to a lens collimator is used. The
lamp bulb is grounded on the outside and is tilted with respect to the
optical axis to minimize channelling artefacts (Blumenstock et al., 2021).
The spectrometer resides on a table, while the lamp is mounted on a tripod
at about 4.20 m (4.0 m for instruments calibrated before January 2020) from the first mirror of the solar tracker attached to the
spectrometer. The position of the lamp is level with the tracker, and the
beam is steered towards the first tracker mirror.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e1333">Set-up of the open-path measurements. The central part of the
illustration schematically shows all the components and the alignment of the
experimental set-up, while in left and right sides photographic close-up
views are presented. The left photograph shows the view in the opposite
direction from the spectrometer towards the lamp unit, while the right
photograph shows a view from the lamp unit (bottom) towards the spectrometer
with its solar tracker (top): the lamp in the bottom part and the instrument
located at a distance of 4.20 m.</p></caption>
          <?xmltex \igopts{width=483.69685pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f02.png"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Updated measurement procedures</title>
      <p id="d1e1350">The main changes with respect to the old method are described in the
following sub-sections.</p>
<sec id="Ch1.S2.SS2.SSS1">
  <label>2.2.1</label><title>Geometry of the set-up</title>
      <p id="d1e1360">In addition to the open-path procedure (January 2020), a cell set-up has now
been implemented for the calibration of the EM27/SUN spectrometers; the
geometrical arrangement previously used was slightly reconfigured to support
both OP and cell measurements. The spectrometer is now oriented in such a
way that the cell can be conveniently located in the infrared beam on top of
the spectrometer housing (see Figs. 2 and 5a and b). This modification results in a
slightly larger distance between the lamp and the first tracking mirror; in
the past that distance was 4.0 m, and it is now 4.2 m.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS2">
  <label>2.2.2</label><title>Distance travelled by the beam inside the instrument</title>
      <p id="d1e1371">We decided to re-check and thereby noticed that the previously assumed
optical path length inside the spectrometer was underestimated. In order to
derive this distance properly, an optical method was applied. The set-up of
the method is illustrated in Fig. 3 and described
as follows: it uses a digital camera J, a finely structured optical target
printed on a piece of paper E' and pocket lamp E” for illumination of the
target. The aim is to optically measure the inaccessible path section from
the instrument entrance window E' until position E, as shown in that
figure.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3" specific-use="star"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e1376">Light path of the beam inside the instrument coming from the lamp
in E” to the camera at the instrument's entrance A'.</p></caption>
            <?xmltex \igopts{width=355.659449pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f03.png"/>

          </fig>

      <p id="d1e1385">For performing the distance measurement, the solar tracker was unmounted to
gain access to the entrance window. The paper target was located at position
E and illuminated with the pocket lamp. The digital camera equipped with a
telescopic lens was positioned directly in front of the entrance window for
observing the target. The target is focused properly, and the focus position
of the lens is maintained while the spectrometer is removed. Next, the
target is arranged at such a distance from the lens that a sharp image is
re-created. This distance can easily be measured geometrically, and we estimate
the accuracy of the method to be better than 5 cm. In order to determine the
complete optical path inside the instrument, the distances E to F and F to
I are measured with a conventional ruler and added to the distance
calculated with the previously explained method.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e1392">Description of the main changes in the path distance used in the
past and the current ones.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Length</oasis:entry>
         <oasis:entry colname="col2">Old</oasis:entry>
         <oasis:entry colname="col3">New (cm)</oasis:entry>
         <oasis:entry colname="col4">Difference <inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:mtext>abs</mml:mtext><mml:mo>(</mml:mo><mml:mtext>new</mml:mtext><mml:mo>-</mml:mo><mml:mtext>old</mml:mtext><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:mtext>old</mml:mtext></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Lamp to first tracking mirror</oasis:entry>
         <oasis:entry colname="col2">400.0</oasis:entry>
         <oasis:entry colname="col3">430.0</oasis:entry>
         <oasis:entry colname="col4">7.5 %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">(note: deliberate adjustment)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">First tracking mirror to spectrometer housing entrance</oasis:entry>
         <oasis:entry colname="col2">38.0</oasis:entry>
         <oasis:entry colname="col3">33.0</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">13.2</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Spectrometer housing entrance to detector</oasis:entry>
         <oasis:entry colname="col2">58.0</oasis:entry>
         <oasis:entry colname="col3">74.0</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">27.6</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1526">In Table 1, the old and new results for the relevant
distances are presented. Note that the distance between lamp and first
tracker mirror has been changed deliberately. The corrected other two
contributions to the total path length, which are used for the proper
calculation of the <inline-formula><mml:math id="M30" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> partial pressure, have been considered in the
reanalysis of the old lamp measurements. For the analysis of the lamp
measurements after mid-January 2020, the updated values as provided in
Table 1 have been used. The effect on the ILS
parameters via the resulting change in <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> partial pressure is small,
but detectable. We discuss this effect in Sect. 4.1.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS3">
  <label>2.2.3</label><title>Measurement procedure</title>
      <p id="d1e1563">Before the collection of measurements, the tracking mirrors (elevation and
azimuth) are carefully adjusted in order to centre the lamp image on the
field stop. The image of the lamp needs to surpass the field stop's
diameter. This procedure is conveniently carried out using the camera, which
is incorporated in the spectrometer for controlling the solar tracking.</p>
</sec>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Data acquisition and improved processing</title>
      <p id="d1e1575">Before the interferograms are recorded (either with or without the cell in
the path), the pre-gain and gain settings of both detectors are checked. The
manufacturer's data acquisition software OPUS is used to perform the
measurements and to process the DC-coupled interferograms. Ten double-sided
full-resolution scans recorded with 10 kHz scan speed are co-added into one
averaged interferogram, and 30 to 40 averaged interferograms of this kind
are recorded in total to achieve a spectral signal-to-noise ratio in the
range of 2000 to 3000; see Sect. 6.3. As the DC
level of the EM27/SUN is slightly variable as a function of optical path
difference, a DC correction is applied (because the solar observations also
undergo a DC correction). The resulting spectra are normalized to about
unity in the spectral range required for the ILS analysis and are stored
with a zero-filling factor of 8 to support the visual inspection of the
spectral fit quality.</p>
<sec id="Ch1.S2.SS3.SSS1">
  <label>2.3.1</label><title>Required auxiliary data</title>
      <p id="d1e1585">In order to correctly derive the <inline-formula><mml:math id="M32" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> column and ILS parameters,
pressure and temperature need to be measured, both inside the instrument and
outside in the laboratory. The temperature inside the spectrometer is
recorded using the sensor built into the spectrometer by the manufacturer.
The temperature of the laboratory air is recorded using digital thermometers
offering 0.8 <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> accuracy (Lutron MHB-382SD data loggers or thermo
hygrometer barometers of type PCE-THB 40 were used). While in the previous
data analysis the pressure readings of the aforementioned portable sensors
were used, we migrated for the analysis of new measurements as well as for
the re-analysis of previous measurements to the pressure record from the
nearby meteorological tall tower. This tower is operated by the Institute
for Meteorology and Climate Research – Department Troposphere (IMK-TRO), see
Kohler et al. (2018). The pressure sensor used at the tower is calibrated
in regular intervals, and the data accuracy is expected to be within 0.5 hPa.
The tower is located at a distance of about 800 m from our laboratory. We
apply a barometric correction to the pressure data measured at the tower, as
the elevation of the laboratory is higher than the location of the pressure
sensor by approximately 11 m.</p>
</sec>
<sec id="Ch1.S2.SS3.SSS2">
  <label>2.3.2</label><title>Data processing</title>
      <p id="d1e1621">For the retrieval of the ILS parameters, the LINEFIT software version 14.8
(Hase et al., 1999) is used. In order to retrieve the <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> column, a
simple two-parameter ILS model is utilized as described in Frey et al. (2015). The main extension in the retrieval set-up is that the ILS is now
characterized for both the primary and the CO channel. Two different
spectral regions are therefore investigated as shown in
Fig. 4. The previously used spectral window covers
7000–7400 <inline-formula><mml:math id="M35" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, and the newly added window covers 5275–5400 <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>.
The latter window resides in the spectral overlap region covered by both
detectors, allowing a check for a possibly degraded ILS of the CO channel
with respect to the primary channel, because in this spectral window the
retrieval of ILS parameters can be performed from both main channel and CO
channel spectra. A dedicated check of the CO channel seems advisable,
because the primary channel is used as the reference for the interferometric
alignment, while the CO channel is only adjusted to match the alignment of
the primary channel. By comparing the ILS parameters retrieved from the same
spectral window, biases introduced by spectroscopic inconsistencies cancel
out. Therefore, according to the new scheme presented here, three sets of
ILS parameters are retrieved, and the two additional retrievals performed in
the new window are introduced for recognizing a potential misalignment of
the CO detector.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e1667">Typical spectra for both channels, obtained with the COCCON
reference instrument SN37 on 19 March 2021. The highlighted regions
<bold>(a)</bold> and <bold>(b)</bold> are the spectral windows used for the ILS retrievals.</p></caption>
            <?xmltex \igopts{width=469.470472pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f04.png"/>

          </fig>

</sec>
<sec id="Ch1.S2.SS3.SSS3">
  <label>2.3.3</label><?xmltex \opttitle{Empirical update of {$\protect\chem{H_{{2}}O}$} spectroscopic data}?><title>Empirical update of <inline-formula><mml:math id="M37" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> spectroscopic data</title>
      <p id="d1e1704">For the previous ILS analysis, the <inline-formula><mml:math id="M38" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> line list provided by HITRAN
version 2008 (including the corrections introduced in 2009) with some minor
empirical adjustments was used. The work presented here uses a considerably
revised line list. The HITRAN 2016 <inline-formula><mml:math id="M39" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> list served as a starting point
for fitting empirical <inline-formula><mml:math id="M40" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> line parameters in the two relevant spectral
regions using a pair of high-resolution open-path spectra recorded with the
Bruker IFS125HR spectrometer of the TCCON station Karlsruhe. The air
conditioning system of the laboratory container housing the spectrometer was
used to adjust the air temperature to 15 and 30 <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>,
respectively. We assume that this span largely covers the conditions of
laboratory ILS measurements. The pair of spectra were then used for a
multi-spectrum fit of empirical <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> line parameters using the LINEFIT
software with a wrapper for adjusting the line parameters. Line intensities,
line positions and broadening parameters were adjusted (the ratios of the
self and foreign broadening parameters were maintained as reported in the
HITRAN line list). The fit residuals of the high-resolution spectra after
the empirical adjustment are shown in Appendix A
(see Figs. A1 and A2); the <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> line list is provided in the Supplement of this work. In order to avoid a significant bias between the
ILS parameters reported by Frey et al. (2019) and the results of the
reanalysis presented here, a global scaling factor was determined and
applied to the new pressure broadening parameters. As expected, the fit
quality of EM27/SUN open-path spectra using the new empirical line list are
significantly improved, as discussed in Sect. 4.1.</p>
</sec>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><?xmltex \opttitle{Use of a cell filled with a {$\protect\chem{C_{{2}}H_{{2}}}$}--air mixture for ILS characterization}?><title>Use of a cell filled with a <inline-formula><mml:math id="M44" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>–air mixture for ILS characterization</title>
      <p id="d1e1812">In addition to the refinements introduced in the open-path method, a new gas
cell was developed and has been used in parallel with the open-path
measurements. This chapter presents the details of the cell.</p>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Cell components</title>
      <p id="d1e1822">This new method developed for measuring the ILS for EM27/SUN instruments
uses a gas cell filled with <inline-formula><mml:math id="M45" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. This gas is a good choice,
because it is easily accessible and easy to handle, and because it offers a
strong absorption band at 6550 <inline-formula><mml:math id="M46" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, a spectral region largely free
from <inline-formula><mml:math id="M47" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> contamination. In the context of calibration work for TCCON,
experience with <inline-formula><mml:math id="M48" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> has already been collected (see Sect. 3.2).
The cell has an effective length of 200 mm and an internal diameter of 30 mm. Wedged fused silica windows are glued to the slightly angled end
surfaces of the cell body. The cell is closed with a Teflon valve stem,
sealing against a Schott Duran valve body. A temperature sensor is attached
to the cell in order to monitor this variable during the experiment. To fix
the cell into the lamp beam at the level of the tracker beam, a simple
support has been built as shown in Fig. 5c. A
cardboard screen is used to limit the heating of the cell body by the lamp.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e1886">The set-up of the cell measurements and the cell components used in
this study are shown in <bold>(a)</bold>, <bold>(b)</bold> and <bold>(c)</bold>, respectively.</p></caption>
          <?xmltex \igopts{width=441.017717pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f05.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Cell content and calibration</title>
      <p id="d1e1912">A different cell, which is pressure-monitored and filled with 300 Pa of pure
<inline-formula><mml:math id="M49" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, is used at the TCCON station Karlsruhe for calibration work
on the sealed HCl cell as used by the TCCON network; this cell and its
application is described in Hase et al. (2013). Inspection of the fit
residuals of high-resolution <inline-formula><mml:math id="M50" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> spectra recorded with the
IFS125HR spectrometer indicates that in particular the line positions of the
HITRAN 2016 line list are slightly imperfect, so the line positions have
been adjusted. This improved empirical <inline-formula><mml:math id="M51" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> line list is also
applied to the low-resolution work presented here. The empirical
<inline-formula><mml:math id="M52" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> line list is distributed with the LINEFIT code and also
provided as a Supplement to this paper.</p>
      <p id="d1e1979">For low-resolution measurements, we require a higher filling pressure, as
pressure broadening is needed to generate absorption lines of sufficient
area. In the Doppler limit, even saturated lines generate a very weak signal
in the convolved spectrum, because such lines are spectrally much narrower
than the ILS of the EM27/SUN spectrometer. Using an available cell body of
200 mm length, a pressure on the order of 100 hPa was found to be a
reasonable choice.</p>
      <p id="d1e1982">After filling of the cell, a pair of high-resolution reference cell spectra
were recorded using the IFS125HR spectrometer at temperatures around 288 and
303 K. From these spectra, the amount of <inline-formula><mml:math id="M53" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> contained in the
cell was retrieved, which also sets the <inline-formula><mml:math id="M54" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> partial pressure for
a given cell temperature. Next, assuming an ideal ILS for the IFS125HR
spectrometer, the relevant cell parameters were retrieved using LINEFIT. The
results for <inline-formula><mml:math id="M55" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> total and partial pressure are provided in
Table 2. While the partial pressure results from the
measured line area follow the ideal gas law, the retrieved total pressure
which minimizes spectral residuals deviates from the ideal gas law. It
should not be regarded as a physical parameter, and it is used to compensate for
various imperfections (reported values of self and foreign pressure
broadening parameters and their temperature dependence, possible air
contamination in the cell, etc.). For adjusting these parameters to other
working temperatures, we apply a linear interpolation in both tabulated
parameters of the total and partial pressure.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e2037">Measured variables in the cell with respect to the IFS125HR
spectrometer at Karlsruhe TCCON station.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M56" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> [K]</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mtext>tot</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> [hPa]</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mtext>part</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> [hPa]</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">288.2</oasis:entry>
         <oasis:entry colname="col2">138.0</oasis:entry>
         <oasis:entry colname="col3">121.8</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">303.2</oasis:entry>
         <oasis:entry colname="col2">147.8</oasis:entry>
         <oasis:entry colname="col3">128.1</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Measurement set-up</title>
      <p id="d1e2128">When the cell is positioned in the open-path set-up, we maintain the
4 m distance between the lamp and spectrometer. This does not bring
in complications, because the <inline-formula><mml:math id="M59" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> lines superimposed to the observed
<inline-formula><mml:math id="M60" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> band are sufficiently weak. Therefore, we can easily go back
and forth between the open-path and cell configuration. The <inline-formula><mml:math id="M61" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
cell introduces a slight beam deviation because the window wedges do not
fully compensate, but the camera incorporated in the EM27/SUN can be
conveniently used for realigning the image of the lamp collimator on the
spectrometer's entrance field stop. After the warm-up phase of the
spectrometer discussed in Sect. 2.1, 10 to 16
interferograms are collected using a 10 kHz scan speed (each interferogram
comprised of 10 co-added scans).</p>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Error budget of the cell measurement for measuring ILS parameters of the EM27/SUN spectrometer</title>
      <p id="d1e2184">With the spectral noise level achieved by applying the measurement procedure
outlined in Sect. 4.3, the propagation of spectral noise into the
retrieved ILS parameters turns out to be a negligible contribution. The
error budget of the ILS parameters is dominated by the knowledge of the gas
cell temperature, which might vary while the measurement is performed and
across the cell body. We assume that the knowledge of cell temperature
during the measurement is on the order of 1 to 2 K. A change in the
temperature by 1 K changes the retrieved modulation efficiency amplitude by
about 0.25 %. The empirical cell pressure parameters described in Sect. 3.2 used for the analysis of cell spectra also suffer from experimental
uncertainty. The IFS125HR spectrometer might deviate slightly from an ideal
spectrometer, and the analysis of the spectra used for the calibration of the
cell parameters suffers from imperfect measurement of cell temperature. In
the subsequent application of the cell, we estimate an uncertainty of the
cell pressure parameters on the order of 0.5 %, which produces a systematic
error contribution of about 0.36 %. Table 3
summarizes the error budget of the cell measurement.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e2190">Estimated error budget of the MEA (modulation efficiency amplitude)
ILS parameter for the <inline-formula><mml:math id="M62" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cell measurement procedure.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="justify" colwidth="140pt"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Error source</oasis:entry>
         <oasis:entry colname="col2">Uncertainty</oasis:entry>
         <oasis:entry colname="col3">Propagation on MEA</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Spectral signal-to-noise ratio</oasis:entry>
         <oasis:entry colname="col2">2000</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Temperature</oasis:entry>
         <oasis:entry colname="col2">1 K</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Empirical cell pressure parameters <?xmltex \hack{\hfill\break}?>(systematic error contribution)</oasis:entry>
         <oasis:entry colname="col2">0.5 %</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mn mathvariant="normal">3.6</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<?xmltex \hack{\newpage}?>
</sec>
<sec id="Ch1.S3.SS5">
  <label>3.5</label><title>Data acquisition and pre-processing and final processing</title>
      <p id="d1e2334">The OPUS software provided by the manufacturer Bruker is used to collect the
interferograms. The settings used for their acquisition are the same as for
the open-path method. Once the interferograms are recorded, they are
pre-processed using OPUS in the same way as explained in the open-path
method; namely a DC correction is included. After generating a spectrum, the
ILS is retrieved using LINEFIT 14.8. Figure 6 shows
an open-path spectrum recorded with the <inline-formula><mml:math id="M66" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cell inserted in the
beam. The <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> band located in the wavenumber range 6450–6630 <inline-formula><mml:math id="M68" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> is utilized for the retrieval of ILS parameters.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e2385">An open-path spectrum recorded with the <inline-formula><mml:math id="M69" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cell
inserted in the beam. The spectrum was recorded using COCCON's EM27/SUN
reference spectrometer SN37. The insert shows a zoom-in of the wavenumber
range used for the retrieval of ILS parameters from <inline-formula><mml:math id="M70" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f06.png"/>

        </fig>

</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Discussion of open-path results</title>
      <p id="d1e2435">In this section, we will discuss the results of the open-path measurements,
achieved by applying the improved and extended methods introduced in Sect. 2. Firstly, we apply the new refined analysis
procedure to the open-path measurements collected by Frey et al. (2019), and
we compare the results of this reanalysis with the previously reported
results. Next, the results derived from the standard spectral window are
compared with results obtained using the micro window in the spectral
overlap region, which is accessible by both detectors. As described in
Sect. 2.3, this additional spectral micro window
was implemented for detecting a potential misalignment of the CO detector
element. This performance test was not included in the previous open-path
recipe. Finally, our best estimate of the instrumental line shape parameters
is provided for all tested spectrometers. The table summarizing the revised
results contains the revised values for those spectrometers investigated in
the study by Frey et al. (2019) and new results for the spectrometers,
which have been calibrated since then.</p>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Reanalysis of previous open-path measurements</title>
      <p id="d1e2445">Figure 7 shows, for all spectrometers treated in the
work of Frey et al. (2019), the old and newly derived modulation efficiency
amplitudes (MEAs), the phase errors (PEs), the new-minus-old differences for
both quantities and the empirical standard deviation of the spectral
residuals. The use of the revised <inline-formula><mml:math id="M71" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> line list significantly reduced
the spectral residuals. Figure 8 shows an excellent
correlation between old and new MEA and PE (<inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.95</mml:mn></mml:mrow></mml:math></inline-formula>) results.
Figure 9a shows that due to the
empirical calibration of the <inline-formula><mml:math id="M73" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> broadening parameters mentioned in
Sect. 2, only a small bias in MEA is seen, the mean of the new MEA results
being higher by 0.04 %. Figure 8b indicates a significant
reduction of PE values; so probably part of the previously diagnosed ILS
asymmetry was introduced by systematic spectral residuals created by the
HITRAN 2008 line parameters. Overall, the revised analysis recipe confirms
the results by Frey et al. (2019), as spectrometers showing suspiciously
high or low values of MEA or PE versus the average behaviour retain their
characteristics. Although we are confident that the new method, using an
improved line list, a correction of the optical distance (and thereby
<inline-formula><mml:math id="M74" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> self-broadening effects) and more reliable data for the total
pressure, is superior to the original method, the overall effect is only a
gradual improvement. The reanalysis of the old spectra is important mainly
in order to avoid a systematic bias of reported ILS parameters between
previous and current calibrations.</p>

      <?xmltex \floatpos{p}?><fig id="Ch1.F7" specific-use="star"><?xmltex \currentcnt{7}?><?xmltex \def\figurename{Figure}?><label>Figure 7</label><caption><p id="d1e2504">Comparison between the old published values (blue star) and the
improved ones (black dotes). The MEA, PE and new-minus-old difference
for each spectrometer. The bottom panel shows the resulting empirical
standard deviation of the spectral fit for the old and the new methods,
respectively.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f07.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><?xmltex \def\figurename{Figure}?><label>Figure 8</label><caption><p id="d1e2515"><bold>(a)</bold> Correlation between the MEA obtained with the new and
the old methods for the shortwave standard micro window (SSW). <bold>(b)</bold>
Correlation between the PE obtained with the new and the old methods. The
colour bar represents the serial number (SN) of the instruments.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f08.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9" specific-use="star"><?xmltex \currentcnt{9}?><?xmltex \def\figurename{Figure}?><label>Figure 9</label><caption><p id="d1e2532">Box-and-whisker plots showing the statistics of the original data
analysis by Frey et al. (2019) and the reanalysis: median, mean, scatter and
interquartile range are presented. <bold>(a)</bold> MEA. <bold>(b)</bold> PE.</p></caption>
          <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f09.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Open-path results for all spectrometers</title>
      <p id="d1e2555">In this section, the ILS parameters for all spectrometers as retrieved with
the improved analysis procedure are presented. The left panel of
Fig. 10 provides a graphical overview of these new
results, including the reanalysis results for the spectrometers already
investigated by Frey et al. (2019). In total 47 new spectrometers were
investigated. As can be seen from the figure, the results for new
spectrometers are in line with the previous work, but the occurrence of
outliers seems reduced (the clearly deviating behaviour of spectrometers 75
and 76 uncovered by the calibration work was later diagnosed to be caused by
misassembled detector baseplates). Presumably, this reflects the gain of
expert knowledge in the fabrication of the EM27/SUN spectrometer type and in
the acceptance and calibration procedures. We suppose that the continued
efforts for quality assurance presented in this work contribute to the high
level of consistency achieved in the spectrometers' characteristics that is
apparent today. Table S1 in the Supplement collects the ILS
results for all spectrometers.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10" specific-use="star"><?xmltex \currentcnt{10}?><?xmltex \def\figurename{Figure}?><label>Figure 10</label><caption><p id="d1e2560">Main results for the main <bold>(a, c, e, g)</bold> and CO detector channels
<bold>(b, d, f, h)</bold> resulting from the revised open-path method. The modulation
efficiency, phase error, rms and relative difference for the first channel
by using SSW and OVR are shown in <bold>(a)</bold>, <bold>(c)</bold>, <bold>(e)</bold> and <bold>(g)</bold>, respectively, while the
modulation efficiency, phase error, rms and relative difference for the
first and second channels using SSW and OVR are presented in <bold>(b)</bold>, <bold>(d)</bold>, <bold>(f)</bold> and <bold>(h)</bold>,
respectively.</p></caption>
          <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f10.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS3">
  <label>4.3</label><title>Testing the alignment of the CO channel</title>
      <p id="d1e2608">The addition of a further spectral window to the open-path analysis in the
spectral overlap region covered by both the main and the CO channel allows
the extension of the open-path ILS analysis to the CO channel. The CO
channel is an extension of the original design of the EM27/SUN (Hase et al.,
2016). CO is an air pollutant and also useful for the source apportionment
of <inline-formula><mml:math id="M75" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emissions. CO is measured by space sensors as Measurement of
Pollution in the Troposphere (MOPITT) (Drummond et al., 2010; Drummond and Mand,
1996) and the TROPOspheric Monitoring Instrument (TROPOMI) (Veefkind et al.,
2012). Today, all EM27/SUN spectrometers incorporate both detector channels.
Therefore, it is desirable to include a procedure in the calibration which
recognizes the potential for a significant misalignment of the CO detector
element with respect to the main detector. Such a misalignment of the CO
detector would generate (1) deviating ILS parameters and (2) a deviating
spectral scaling factor.</p>
      <p id="d1e2622">In this section we compare the consistency of spectral fits in the standard
spectral window (SSW) and in the overlap region (OVR) using the spectra
recorded with the main detector. We compare the retrieved ILS parameters
(MEA and PE) and spectral scaling factors. In Sect. 4.3.1, we investigate the consistency of ILS results
between the SSW and OVR windows using spectra recorded with the main
detector channel.</p>
      <p id="d1e2625">In Sect. 4.3.2, we discuss the results from the
OVR region, this time using spectra recorded with the CO detector instead of
the main detector.</p><?xmltex \hack{\newpage}?>
<sec id="Ch1.S4.SS3.SSS1">
  <label>4.3.1</label><title>Consistency of spectral fitting in the standard spectral window and the overlap region</title>
      <p id="d1e2637">Figure 11 (top panel) compares the MEA and PE of
retrievals performed in the SSW and in the OVR using the main detector. The
results show good agreement (MEA: <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.78</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:mtext>PE</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.95</mml:mn></mml:mrow></mml:math></inline-formula>). It is very
interesting to observe that the regression line has a slope significantly
below <inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>. Since parameters such as MEA and PE measure fractional wave front
errors, their deviations from the nominal value are indeed expected to
increase with increasing wavenumber. The wavenumber ratio between OVR and
SSW is 0.74, while the slope of the MEA regression line is 0.63, which would
support the assumption of a steeper-than-linear wavenumber dependence of the
MEA parameter (<inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:msup><mml:mi mathvariant="italic">ν</mml:mi><mml:mn mathvariant="normal">1.5</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>). The PE results are compatible with the
assumption of a linear wavenumber dependence.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11" specific-use="star"><?xmltex \currentcnt{11}?><?xmltex \def\figurename{Figure}?><label>Figure 11</label><caption><p id="d1e2694">Correlation plots between the MEAs <bold>(a, c, e)</bold> and PEs <bold>(b, d, f)</bold>. <bold>(a, b)</bold> The first channel in the SSW and in the OVR region, <bold>(c, d)</bold> the first channel in the SSW and the second channel in the OVR region, and <bold>(e, f)</bold> the first channel in the OVR and the second channel
in the OVR region. Additionally, the obvious outliers are labelled in
order to assess them.</p></caption>
            <?xmltex \igopts{width=384.112205pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f11.png"/>

          </fig>

      <p id="d1e2718"><?xmltex \hack{\newpage}?>As can be seen from Fig. 12, there is a small bias
of 0.3 % in MEA between the primary channel results deduced from the SSW
and OVR spectral regions: the values retrieved in the OVR are slightly
higher than those from the SSW. The PE retrieved in the OVR is significantly
smaller, which might indicate that the revised spectroscopic description of
the SSW spectral window – although the new line list reduced the retrieved
PE by a factor of 2 (see Sect. 4.1) – still simulates a spurious PE
bias. The spectral fit quality in the SSW and OVR regions is quite
comparable for the primary channel (Fig. 11, bottom panels), while the OVR
spectral fits to the measurements recorded with the CO detector indicate a
somewhat higher noise level.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12"><?xmltex \currentcnt{12}?><?xmltex \def\figurename{Figure}?><label>Figure 12</label><caption><p id="d1e2725">Box plots comparison for the three-wavenumber ranges used with
the open-path method showing the MEAs, PEs and rms.</p></caption>
            <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f12.png"/>

          </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F13" specific-use="star"><?xmltex \currentcnt{13}?><?xmltex \def\figurename{Figure}?><label>Figure 13</label><caption><p id="d1e2736">Instrumental variation in the spectral scaling factors in each of
the spectral windows used and for both channels.</p></caption>
            <?xmltex \igopts{width=441.017717pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f13.png"/>

          </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F14" specific-use="star"><?xmltex \currentcnt{14}?><?xmltex \def\figurename{Figure}?><label>Figure 14</label><caption><p id="d1e2747">Correlations between the scaling factors derived from OVR and SSW
spectral windows using the main channel spectra <bold>(a)</bold> and using CO
channel results for the OVR spectral window <bold>(b)</bold>.</p></caption>
            <?xmltex \igopts{width=441.017717pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f14.png"/>

          </fig>

      <p id="d1e2762">Figure 13 summarizes the results for the spectral
scaling factors for both spectral windows as resulting from the LINEFIT
fits. Figure 14a compares the spectral
scaling factors of OVR and SSW fits as deduced from main detector spectra.
As one would expect, the slope is near <inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>, and the correlation is very
high.</p>
</sec>
<sec id="Ch1.S4.SS3.SSS2">
  <label>4.3.2</label><title>Evaluation of the CO detector alignment using the spectral overlap region</title>
      <p id="d1e2785">Figure 11 (middle and lower panels) shows the MEA and
PE correlations as deduced from the main detector and the CO detector,
respectively. Figure 11, middle panel, shows the
correlation of MEA between the CO detector (OVR) and main detector (SSW).
While the shallower slope is comparable with the results reported in Sect. 4.3.1, the correlation between the two different
detectors is significantly poorer. There are several outliers from the MEA
regression line: these are spectrometers 39, 42, 53, 75, and 110. In the
PE regression, the five results furthest from the regression line are
50, 94, 110, 111 and 143.</p>
      <p id="d1e2788">Figure 14b compares the spectral
scaling factors of OVR fits for the two CO and main detectors. While the
slope is in excellent agreement with the results derived from the main
detector, there is more scatter (<inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.95</mml:mn></mml:mrow></mml:math></inline-formula>). The results for
spectrometers 39 and 41 are furthest from the regression line.</p>
      <p id="d1e2806">In summary, although the correlation of ILS parameters and spectral scaling
factors is noisier between the main and CO detectors, only one consistent
outlier appears, which is spectrometer SN39. Altogether the applied OVR
tests do not detect unacceptable misalignments of the CO detector. The
relative spectral detuning of SN39 between SSW and OVR is on the order of
<inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, which, by applying <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>v</mml:mi></mml:mrow><mml:mi>v</mml:mi></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">2</mml:mn></mml:mfrac></mml:mstyle><mml:msup><mml:mi mathvariant="italic">α</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>
using <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mi mathvariant="italic">α</mml:mi><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn></mml:mrow></mml:math></inline-formula> mrad, is equivalent to about one-seventh of the apparent
solar diameter. Here <inline-formula><mml:math id="M85" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> denotes the maximum inclination of a ray
still accepted by the interferometer. The effect of a misadjusted field stop
on spectral scale is discussed by Kauppinen and Saarinen (1992). The
majority of spectral detuning results are located within <inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, equivalent to an angular misalignment of <inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">14</mml:mn></mml:mrow></mml:math></inline-formula> of the apparent
solar diameter, which is in reasonable agreement with the expected alignment
precision of the CO detector. Because the air mass reference is deduced from
the oxygen band observed in the main channel, such a misalignment introduces
an error in the XCO data. If we assume a misalignment of <inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> of the
apparent solar disc diameter along the vertical, the resulting relative
error in XCO at an 80<inline-formula><mml:math id="M89" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> solar zenith angle amounts to 0.5 %.</p>
</sec>
</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><?xmltex \opttitle{Discussion of {$\protect\chem{C_{{2}}H_{{2}}}$} cell results}?><title>Discussion of <inline-formula><mml:math id="M90" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cell results</title>
      <p id="d1e2956">In Sect. 3, the construction and calibration of a
cell filled with <inline-formula><mml:math id="M91" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are described. Here, we compare in detail the
results obtained from the open-path measurements (OP) using the <inline-formula><mml:math id="M92" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>
lines forming in the laboratory air with those obtained with the cell
method. Because the cell measurements were implemented in the beginning of
2020, only for spectrometers tested afterwards are cell results available. The
comparison is based on the standard <inline-formula><mml:math id="M93" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> window covering 7000–7400 <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> discussed in Sect. 2 and the
<inline-formula><mml:math id="M95" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> spectral window covering 6450–6630 <inline-formula><mml:math id="M96" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> discussed in
Sect. 3, so spectra recorded with the main
detector are used.</p>
<sec id="Ch1.S5.SS1">
  <label>5.1</label><title>Intercomparison of repeated open-path and cell measurements using the reference spectrometer</title>
      <p id="d1e3053">In order to investigate the stability of both methods, OP and cell
measurements were taken repeatedly under different laboratory conditions
using the COCCON reference instrument SN37. On a total of 16 d,
measurements were performed during February and March 2021. For each daily
set of measurements, included sequential OP and cell measurements were taken
within 45 min to ensure the laboratory conditions were comparable. We
collected 15 interferograms for the cell test and 30 for the OP method.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F15" specific-use="star"><?xmltex \currentcnt{15}?><?xmltex \def\figurename{Figure}?><label>Figure 15</label><caption><p id="d1e3058">Time series of the MEAs, PEs, <inline-formula><mml:math id="M97" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> retrieved column and
difference between the MEAs retrieved with OP and cell method for the COCCON
reference instrument SN37 (<bold>a</bold>, <bold>b</bold>, <bold>c</bold> and <bold>d</bold>, respectively).</p></caption>
          <?xmltex \igopts{width=355.659449pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f15.png"/>

        </fig>

      <p id="d1e3095">Figure 15 shows the internal variability of the
results. Both methods seem to offer similar repeatability. While we do not
see a clear advantage of the cell approach from the comparison in this
regard, we need to acknowledge the fact that the <inline-formula><mml:math id="M98" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> line widths
are properly calibrated. If we assume that the TCCON spectrometer used to
calibrate the empirical <inline-formula><mml:math id="M99" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cell parameters can be regarded as an
ideal reference (see Sect. 3.2), this finding
suggests that the OP MEA results indeed suffer from a systematic low bias of
about 0.015 (1.5 %) and that the ILS performance of the EM27/SUN is on
average closer to the nominal expectation than indicated by the OP
measurements (see Fig. 16). This adjustment will
be included in a future version of the PROFFAST software used by COCCON for
the analysis of atmospheric spectra. The current version of the code uses
the MEA values resulting from the OP measurements, so the currently
incorporated values of the air-mass-independent and air-mass-dependent
calibrations are partly mitigating the bias in MEA.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F16"><?xmltex \currentcnt{16}?><?xmltex \def\figurename{Figure}?><label>Figure 16</label><caption><p id="d1e3133">Same as Fig. 9 but for the sensitivity
study for the COCCON reference instrument SN37. Left part of the display:
open-path results; right part: cell results.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f16.png"/>

        </fig>

      <p id="d1e3142">Even though the cell method does not provide a significant improvement in
the determination of MEA and PE values, we plan to maintain the cell
measurements in the calibration procedure. That the cell measurement
delivers a column value, which can be measured with excellent precision and
provides an invariant for the comparison of different spectrometers, seems a
useful addition. The relative 1-sigma standard deviation of the
<inline-formula><mml:math id="M100" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column indicated by the repeated measurements is 0.0008 %
(individual column results are shown in Fig. 15c).</p>
</sec>
<sec id="Ch1.S5.SS2">
  <label>5.2</label><title>Intercomparison of cell results with open-path results</title>
      <p id="d1e3169">This section summarizes the main results of the ILS characterization for the
first channel by using the OP and the cell method for the spectrometers
tested since 2020 (see Figs. 17–19).
Figure 17 shows the instrumental variation in the MEA
and PE, <inline-formula><mml:math id="M101" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column, and rms according to both methods. The MEA
retrieved with the cell method is higher and closer to the ideal ILS in
comparison with the OP method, which supports the finding discussed in the
previous section that the cell method retrieves <inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn></mml:mrow></mml:math></inline-formula> %
higher MEA values. The <inline-formula><mml:math id="M103" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> columns do show more scatter between
different spectrometers than the repeated measurements performed using the
reference spectrometer, but still is very low, at a level of 0.0003 %.
Figure 18 shows the correlation between the OP and
the cell MEA and PE results, and Fig. 19 shows a
statistical comparison. We find a reasonable correlation, which indicates
that despite the tendency that the spectrometers become more uniform in
their characteristics, we are still able to detect – using the described
laboratory procedures – actual variations in the MEA and PE values. The
sensitivities differ between the methods: while the slope of the MEA
regression line is compatible with our assumption of a <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:msup><mml:mi mathvariant="italic">ν</mml:mi><mml:mn mathvariant="normal">1.5</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> wavenumber dependence of the MEA parameter (see
discussion in Sect. 4.3.2), the slope of the PE
regression line is surprisingly steep, as we would expect PE to be
proportional to wavenumber. However, the spectral scenes are quite
different; the <inline-formula><mml:math id="M105" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> lines offer a significantly smaller width than
the <inline-formula><mml:math id="M106" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> lines. Therefore, the ILS deviations associated with
contributions emerging from larger optical path difference (OPD) will gain
importance in the <inline-formula><mml:math id="M107" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> spectral fitting. The assumption of a
constant PE might be too coarse and therefore introduces the observed
discrepancy between the two methods. When regarded from this perspective,
the continuation of the <inline-formula><mml:math id="M108" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> measurements in addition to OP might
also become useful for introducing further refinements of the ILS model in
the future. Figure 19 summarizes the performance of
both methods.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F17" specific-use="star"><?xmltex \currentcnt{17}?><?xmltex \def\figurename{Figure}?><label>Figure 17</label><caption><p id="d1e3291">The modulation efficiency as a function of the instrumental SN,
phase error, <inline-formula><mml:math id="M109" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column, rms of the spectral fit and the relative
difference between the open-path method and the cell method are presented in <bold>(a)</bold>,
<bold>(b)</bold>, <bold>(c)</bold>, <bold>(d)</bold> and <bold>(e)</bold>, respectively.</p></caption>
          <?xmltex \igopts{width=355.659449pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f17.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F18" specific-use="star"><?xmltex \currentcnt{18}?><?xmltex \def\figurename{Figure}?><label>Figure 18</label><caption><p id="d1e3334">Correlations between the MEAs obtained with the OP and cell
methods for the first channel.</p></caption>
          <?xmltex \igopts{width=355.659449pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f18.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F19"><?xmltex \currentcnt{19}?><?xmltex \def\figurename{Figure}?><label>Figure 19</label><caption><p id="d1e3346">MEA and rms statistical results from the ILS retrievals by using
the OP and the cell methods for the first channel of the available
instruments (left part of the display: open path; right part: cell).</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f19.png"/>

        </fig>

</sec>
</sec>
<sec id="Ch1.S6">
  <label>6</label><title>Discussion of solar side-by-side calibration measurements</title>
<sec id="Ch1.S6.SS1">
  <label>6.1</label><title>Long-term stability of reference unit</title>
      <p id="d1e3371">In this section the historic time series of the COCCON reference instrument
SN37 is assessed by comparing the main target gases: <inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO,
<inline-formula><mml:math id="M111" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> with the results obtained from the high-resolution
spectrometer IFS125HR located at KIT Campus North (<inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:mn mathvariant="normal">49</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">06</mml:mn><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">00.8</mml:mn><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> N,
<inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">26</mml:mn><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">18.6</mml:mn><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> E, 112 m a.s.l.). This spectrometer contributes to the
TCCON network. Two different kinds of measurements were collected with the
IFS125HR spectrometer: standard TCCON measurements using a spectral
resolution equivalent to max. OPD of 45 cm and double-sided low-resolution
spectra for mimicking the EM27/SUN observations (maximum OPD 1.8 cm). The
COCCON and the low-resolution data recorded with the IFS125HR were analysed
using PROFFAST, while the high-resolution spectra were used for generating
the official TCCON product using the GGG software suite version 2014 (Wunch
et al., 2015). Because it provides a very sensitive indication for
instrumental drifts and operation problems, we also investigate results
for <inline-formula><mml:math id="M115" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> here. This quantity compares the spectroscopically determined dry-air column as extrapolated from the observed vertical column of <inline-formula><mml:math id="M116" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
<inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:msub><mml:mtext>VC</mml:mtext><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> with the dry-air column calculated from ground pressure and
spectroscopically observed water vapour column <inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:msub><mml:mtext>VC</mml:mtext><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, as given
in Eq. (1).
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M119" display="block"><mml:mrow><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">0.2095</mml:mn><mml:mrow><mml:msub><mml:mtext>VC</mml:mtext><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>⋅</mml:mo><mml:mover accent="true"><mml:mi mathvariant="italic">μ</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:mfenced open="(" close=")"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi>S</mml:mi></mml:msub></mml:mrow><mml:mi>g</mml:mi></mml:mfrac></mml:mstyle><mml:mo>-</mml:mo><mml:msub><mml:mtext>VC</mml:mtext><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>⋅</mml:mo><mml:mi mathvariant="italic">μ</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mrow></mml:mfenced></mml:mrow></mml:math></disp-formula></p>
<sec id="Ch1.S6.SS1.SSS1">
  <label>6.1.1</label><title>PROFFAST code and COCCON reference EM27/SUN spectrometer</title>
      <p id="d1e3594">The initial development and further improvements of the PROFFAST code are
supported by the European Space Agency (ESA) in the framework of the
COCCON-PROCEEDS project. The code aims at efficient analysis of greenhouse
gases from ground-based near-infrared solar absorption spectra. Together
with the pre-processing code PREPROCESS, it forms the data analysis chain of
COCCON. The code is open source and freely available. It performs least-squares fitting of the spectra by adjusting scaling factors on the a priori
profiles of the trace gases and auxiliary parameters. It is important in the
context of this work that PROFFAST is capable of taking into account the ILS
parameters as determined by the open-path measurements. If this information
is neglected, additional scatter between the atmospheric trace gas results
achieved with different spectrometers would result, and different
gas-specific empirical calibration factors would result from the
side-by-side solar observations for each spectrometer (these factors are
reported in Sect. 6.2). Additional information on the code is provided by
Frey et al. (2021) and Sha et al. (2020).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F20" specific-use="star"><?xmltex \currentcnt{20}?><?xmltex \def\figurename{Figure}?><label>Figure 20</label><caption><p id="d1e3599">Time series of <inline-formula><mml:math id="M120" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO, XCH4, <inline-formula><mml:math id="M121" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M122" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
measured with the COCCON reference instrument (blue), from the TCCON station
Karlsruhe (derived from high-resolution IFS125-HR spectra using GGG2014,
red) and derived from low-resolution IFS125-HR spectra (black). The
low-resolution measurements were processed with PROFFAST.</p></caption>
            <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f20.png"/>

          </fig>

      <p id="d1e3643">The EM27/SUN spectrometer SN37 has served as the COCCON reference
spectrometer since 2014. The spectrometer participated in the Berlin
campaign (Hase et at., 2015) and was upgraded with the CO channel in early
2018. Figure 20 presents the time series of
<inline-formula><mml:math id="M123" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO, <inline-formula><mml:math id="M124" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M125" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M126" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> covering 2015 to the end of
2020. Shown are the official TCCON data generated with the GGG2014 software
suite and data derived from the low-resolution spectra recorded with the
IFS125HR spectrometer and the COCCON reference spectrometer, respectively,
using the PROFFAST code. For the target gases, no obvious drifts are
noticeable between the different data sets. The bias in <inline-formula><mml:math id="M127" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> between
the TCCON and low-resolution data is due to the trivial fact that <inline-formula><mml:math id="M128" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
is not generated as a calibrated quantity by GGG2014, while PROFFAST
attempts a normalization to unity. However, there is a change of <inline-formula><mml:math id="M129" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>
apparent in the COCCON reference data during the first 4 years, which we
investigate further in the next section. We will show that these changes are
small enough not to detectably affect the results of the target gases apart
from <inline-formula><mml:math id="M130" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S6.SS1.SSS2">
  <label>6.1.2</label><?xmltex \opttitle{Changes of {$\protect\chem{X_{\text{AIR}}}$} in time series of reference spectrometer}?><title>Changes of <inline-formula><mml:math id="M131" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> in time series of reference spectrometer</title>
      <p id="d1e3757">Figure 22 shows the variations in <inline-formula><mml:math id="M132" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> of the
COCCON reference unit with respect to the low-resolution IFS125HR data. At
least two step changes appear, at the end of 2015 and at the end of 2017.
Since 2018, the results appear stable. The step change at the end of 2017 is very
likely associated with the CO channel upgrade of the spectrometer, while the
earlier event might be associated with a realignment of the spectrometer
performed in the winter period after participation of the unit in the Berlin
campaign between June and July 2014 (Hase et al., 2015). The analysis of
atmospheric spectra collected with the reference unit was performed twice:
in one analysis, it was assumed that the ILS is time independent (the ILS
parameters used for the analysis were derived from averaging the parameters
from all available ILS measurements performed with the reference
spectrometer). In the other analysis, yearly values for the ILS parameters
were applied as deduced from the available open-path measurements. With the
exception of 2015, the <inline-formula><mml:math id="M133" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> results appear more consistent if
time-dependent ILS parameters are used for the data analysis. In 2015, only
a single ILS measurement was performed and might for some reason be of
inferior quality. A reanalysis of the open-path spectra uncovered at least
the use of an erroneous ground pressure value in the original analysis of
this measurement reported by Frey et al. (2019) and resulted in less
anomalous values for the ILS parameters. The revised set of values (<inline-formula><mml:math id="M134" display="inline"><mml:mrow><mml:mtext>MEA</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.98417</mml:mn></mml:mrow></mml:math></inline-formula> and 0.98430 and <inline-formula><mml:math id="M135" display="inline"><mml:mrow><mml:mtext>PE</mml:mtext><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.00061</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M136" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.00068 instead of <inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:mtext>MEA</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.98555</mml:mn></mml:mrow></mml:math></inline-formula> and 0.98940 and <inline-formula><mml:math id="M138" display="inline"><mml:mrow><mml:mtext>PE</mml:mtext><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.00086</mml:mn></mml:mrow></mml:math></inline-formula> and 0.08658) has been used in the
current analysis for the 2014 and 2015 period, but the MEA value is still
suspiciously high. The OP procedures were less refined in the beginning
(e.g. no venting of the spectrometer was performed), so the measurements are
less reliable than current OP measurements.</p>
      <p id="d1e3842">The consideration of the variable ILS brings the <inline-formula><mml:math id="M139" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> results from 2016
and 2017 in better agreement with the more recent results, with only the
2014 to 2015 period remaining as an outlier. We therefore conclude that the
assumption that real ILS changes occurred in the early years due to
instrumental interventions and upgrades is the best choice. The results
shown in Figs. 20, 21 and 23 all refer to the analysis run
using the variable ILS parameters.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F21" specific-use="star"><?xmltex \currentcnt{21}?><?xmltex \def\figurename{Figure}?><label>Figure 21</label><caption><p id="d1e3858">Correlations between <inline-formula><mml:math id="M140" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO, <inline-formula><mml:math id="M141" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M142" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>
between the ones retrieved by using the COCCON reference and the IFS125-LR
low-resolution data (left panels) and between COCCON reference and TCCON
station (right panels).</p></caption>
            <?xmltex \igopts{width=409.719685pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f21.png"/>

          </fig>

      <?xmltex \floatpos{p}?><fig id="Ch1.F22" specific-use="star"><?xmltex \currentcnt{22}?><?xmltex \def\figurename{Figure}?><label>Figure 22</label><caption><p id="d1e3905">Correlations for the retrieved <inline-formula><mml:math id="M143" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> by using the instrument
SN37 and IFS125-LR. Panel <bold>(a)</bold> shows the results of the analysis of
atmospheric spectra under the assumption of a constant ILS, and <bold>(b)</bold>
shows the results under the assumption of a variable ILS (ILS parameters
adjusted on a yearly basis).</p></caption>
            <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f22.png"/>

          </fig>

      <?xmltex \floatpos{p}?><fig id="Ch1.F23" specific-use="star"><?xmltex \currentcnt{23}?><?xmltex \def\figurename{Figure}?><label>Figure 23</label><caption><p id="d1e3933">Correlations between the species: <inline-formula><mml:math id="M144" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO, <inline-formula><mml:math id="M145" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math id="M146" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> retrieved with the COCCON reference instrument and the TCCON
instrument in low-resolution measurement mode in each row (top-down),
respectively, treated separately by year from 2015 to 2020 in each column for
each species.</p></caption>
            <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f23.png"/>

          </fig>

      <p id="d1e3977">Figures 21 and 23
investigate the correlation of the retrieved dry-air mole fractions between
the reference spectrometer and the data derived from IFS125-LR measurements.
While no significant changes are detectable for <inline-formula><mml:math id="M147" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO and
<inline-formula><mml:math id="M148" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, the <inline-formula><mml:math id="M149" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> regression line in Fig. 21 is shallower than the <inline-formula><mml:math id="M150" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> line. Figure 23
investigates the correlation year by year. Again, the changes for <inline-formula><mml:math id="M151" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
become apparent. We therefore assume for the <inline-formula><mml:math id="M152" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> time series from
the COCCON reference unit the existence of a non-negligible drift over the
first years. We assume that the reference spectrometer has reached a stable
configuration since 2018, and during this period we use the <inline-formula><mml:math id="M153" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
side-by-side results without further corrections. Before this period, we
derive from Fig. 23 the existence of a low bias of
the reference unit and therefore apply a low <inline-formula><mml:math id="M154" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> bias of
the reference unit of 0.0001 during 2017, 0.0002 in 2016, and 0.00135 in 2015
(relative detuning of <inline-formula><mml:math id="M155" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration). The instrument-specific
<inline-formula><mml:math id="M156" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration factors provided in Sect. 6.2 and in Table S2 in the Supplement
take these corrections of the reference unit into account.</p>
      <p id="d1e4094">The variable bias of the reference unit's <inline-formula><mml:math id="M157" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> despite the fact that a
time-dependent ILS is used in the data analysis might indicate that the ILS
model currently used by PROFFAST is too simple or that the assumptions made
on the wavenumber dependence of the ILS parameters are incorrect (the
current version of PROFFAST assumes a linear wavenumber dependence for MEA
and PE while the open-path analysis suggests a quadratic dependence for MEA;
see Sect. 4.3.1) or that additional influencing
factors are affecting the trace gas results.</p>
</sec>
</sec>
<sec id="Ch1.S6.SS2">
  <label>6.2</label><title>Empirical XGAS calibration factors for all tested spectrometers</title>
      <p id="d1e4117">To harmonize the retrieved species when using any COCCON spectrometer,
empirical instrument-specific calibration factors for <inline-formula><mml:math id="M158" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO,
<inline-formula><mml:math id="M159" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M160" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> are calculated from the side-by-side solar
measurements with the reference spectrometer SN37. The instruments are
set up on the seventh floor at the Meteorology and Climate Research –
Atmospheric Trace Gases and Remote Sensing (IMK-ASF) building located at KIT
Campus North (<inline-formula><mml:math id="M161" display="inline"><mml:mrow><mml:mn mathvariant="normal">49</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">05</mml:mn><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">38.7</mml:mn><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> N, <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">26</mml:mn><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mn mathvariant="normal">11.5</mml:mn><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> E, 134 m a.s.l.).
After the measurements are taken, the data are processed using the PROFFAST
software. In this processing, the ILS parameters derived previously from OP
measurements are included for both spectrometers, the spectrometer under
test and the reference unit. Ideally, the resulting gas abundances measured
by the spectrometers would be found to be identical. The residual biases
give rise to instrument-specific empirical calibration factors that are
reported in the following for each spectrometer and target gas. These
empirical adjustments consider all remaining instrumental imperfections
which are not properly quantified in the calibration process or not properly
reflected in the trace gas analysis.</p>
      <p id="d1e4205"><?xmltex \hack{\newpage}?>The correction factors are defined in Eq. (2), where
the <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msubsup><mml:mi>K</mml:mi><mml:mtext>gas</mml:mtext><mml:mtext>SN</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula> is the correction factor and <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:msubsup><mml:mi>X</mml:mi><mml:mtext>gas</mml:mtext><mml:mtext>no-corr</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula> is the
dry-air amount of a defined gas without any correction for a defined gas and
instrument. The correction factors are calculated by comparing a defined gas
retrieved with any EM27/SUN instrument with the reference instrument; a
linear fit forced to zero intercept is performed, and then the slope is taken
as its value.
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M165" display="block"><mml:mrow><mml:msubsup><mml:mi>X</mml:mi><mml:mtext>gas</mml:mtext><mml:mtext>corr</mml:mtext></mml:msubsup><mml:mo>=</mml:mo><mml:msubsup><mml:mi>K</mml:mi><mml:mtext>gas</mml:mtext><mml:mtext>SN</mml:mtext></mml:msubsup><mml:mo>⋅</mml:mo><mml:msubsup><mml:mi>X</mml:mi><mml:mtext>gas</mml:mtext><mml:mtext>no-corr</mml:mtext></mml:msubsup></mml:mrow></mml:math></disp-formula></p>

      <?xmltex \floatpos{p}?><fig id="Ch1.F24" specific-use="star"><?xmltex \currentcnt{24}?><?xmltex \def\figurename{Figure}?><label>Figure 24</label><caption><p id="d1e4267">Correction factors for <inline-formula><mml:math id="M166" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M167" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO and <inline-formula><mml:math id="M168" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>
from left to right, respectively, calculated for all EM27/SUN spectrometers.
The error bar represents the standard deviation, and it is shown only for the
instruments with more than one side-by-side measurement in Karlsruhe. The
dashed line represents the ideal value “1.0” (practically realized by the
COCCON reference spectrometer SN37).</p></caption>
          <?xmltex \igopts{width=495.077953pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f24.png"/>

        </fig>

      <p id="d1e4312">Figure 24 shows and lists the empirical calibration
factors for <inline-formula><mml:math id="M169" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M170" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, XCO and <inline-formula><mml:math id="M171" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> for each spectrometer
investigated. Several spectrometers were calibrated repeatedly, in such
cases the values are mean values (the individual results are provided in
Table S2 in the Supplement). The table also provides the
<inline-formula><mml:math id="M172" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> value for each spectrometer. While the Xgas values are derived
from the measurements taken with the spectrometer under test and the
reference unit, the <inline-formula><mml:math id="M173" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> result is independent of the reference unit.</p>
      <p id="d1e4372">Figure 24 provides a graphical overview of the
tabulated values. The 1-sigma error bars are shown if several calibrations
were performed on a spectrometer. Similar to what has been observed and
discussed before for the ILS parameters (see Sect. 5.1), a trend towards improved consistency of the
calibration factors is suggested, especially for <inline-formula><mml:math id="M174" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M175" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.
XCO is a very weak absorber, and therefore the scatter is largely dominated
by residual channelling (Blumenstock et al., 2021), which continues to show
variable characteristics between individual spectrometers.</p>
</sec>
<sec id="Ch1.S6.SS3">
  <label>6.3</label><title>Spectral signal-to-noise ratio of the EM27/SUN spectrometers</title>
      <p id="d1e4405">In order to assess the distribution of the spectral signal-to-noise ratio
(SNR) of different instruments, these values were calculated for both solar
and laboratory spectra. For both cases the SNR is calculated for several
spectral windows covering both detector channels. The procedure applied is
based on the formula described in the Bruker OPUS © software manual (Bruker, 2017); the SNR is calculated from the ratio of two consecutively measured
spectra. A wavenumber region largely free of absorption gases lines is
selected. A parabola is fitted to the ratio spectrum in the investigated
spectral window and serves as a nominal signal. The rms of the fit residuals
is calculated. This rms value is divided by <inline-formula><mml:math id="M176" display="inline"><mml:msqrt><mml:mn mathvariant="normal">2</mml:mn></mml:msqrt></mml:math></inline-formula> to deliver the SNR of
a single spectrum (because a pair of spectra is used in the procedure). The
wavenumber ranges used for each kind of measurements in each channel are
provided in Table 4. It is important to mention that
for the evaluation of the SNR in solar measurements, two spectra recorded
during noontime were selected in order to minimize the variability of the
solar zenith angle and to use spectra recorded when solar intensity is
maximal. For both solar and laboratory open-path spectra, 10 scans recorded
with 10 kHz scan speed were coadded (total integration time 1 min).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e4419">Description of the wavenumber region utilized for each channel and
for each kind of measurement.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Type of</oasis:entry>
         <oasis:entry colname="col2">Instrument's</oasis:entry>
         <oasis:entry colname="col3">Wavenumber range</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">measurements</oasis:entry>
         <oasis:entry colname="col2">channel</oasis:entry>
         <oasis:entry colname="col3">used [<inline-formula><mml:math id="M177" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>]</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Solar</oasis:entry>
         <oasis:entry colname="col2">First</oasis:entry>
         <oasis:entry colname="col3">6515–6415</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Second</oasis:entry>
         <oasis:entry colname="col3">4500–4400</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">OP at laboratory</oasis:entry>
         <oasis:entry colname="col2">First</oasis:entry>
         <oasis:entry colname="col3">6200–6000</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Second</oasis:entry>
         <oasis:entry colname="col3">4500–4300</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F25" specific-use="star"><?xmltex \currentcnt{25}?><?xmltex \def\figurename{Figure}?><label>Figure 25</label><caption><p id="d1e4525">Instrumental distribution of the SNR for both channels with both
kinds of measurements: solar and OP in the laboratory.</p></caption>
          <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f25.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F26" specific-use="star"><?xmltex \currentcnt{26}?><?xmltex \def\figurename{Figure}?><label>Figure 26</label><caption><p id="d1e4537">Correlations of the SNR obtained in channels 1 and 2, for the
solar and OP measurements in <bold>(a)</bold> and <bold>(b)</bold>,
respectively. In <bold>(a)</bold> the colour code represents the month of the
year when the solar measurements were carried out, for demonstrating the
absence of an obvious seasonal signal in the SNR characteristics. In <bold>(b)</bold>, the colour code represents the instrument's serial number
because these measurements are carried out under controlled laboratory
conditions by using a lamp as a light source. There might be a slight tendency
towards higher SNR in recently built spectrometers.</p></caption>
          <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f26.png"/>

        </fig>

      <p id="d1e4558">In Fig. 25, the SNR values in the selected
spectral regions and both kinds of measurements – open-path and solar –
are presented. For the solar measurements higher scatter of the SNR is found
in comparison with the OP laboratory measurements, which are more consistent.
The SNR values of the solar measurements show a much stronger correlation
between the two channels than the SNR values of the open-path measurements
(see Fig. 26). This higher level of correlation is
expected if the variable SNR is due to variable weather conditions.
Therefore, the SNR values deduced from the open-path measurements are better
suited as an indicator of the SNR performance of each spectrometer. However,
even for the laboratory measurements we expect some artificial variability,
as the preamplifier stages are not identical. As a consequence different
pre-gain and gain settings were used for optimally exploitation of the analog-to-digital converter (ADC)
range. Nevertheless, we can conclude that the SNR typically achieved by the
EM27/SUN in a solar spectrum spans the 3000 to 10 000 <inline-formula><mml:math id="M178" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> range,
and the SNR of a laboratory open-path spectrum is in the 2000 to 4000 <inline-formula><mml:math id="M179" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>  range for the main channel and 1000 to 3000 <inline-formula><mml:math id="M180" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for the CO channel.</p>
</sec>
<sec id="Ch1.S6.SS4">
  <label>6.4</label><?xmltex \opttitle{Effects of improved calibration procedures on {$\protect\chem{XCO_{{2}}}$} calibration}?><title>Effects of improved calibration procedures on <inline-formula><mml:math id="M181" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration</title>
      <p id="d1e4623">Ideally, the explicit description of the instrumental characteristics from
the nominal behaviour as resulting from the calibration procedure would
remove any discrepancy between Xgas results derived from different EM27/SUN
spectrometers. Instrument-specific calibration factors for each gas as
provided in Table S2 in the Supplement would not be
required (they would have identical values across different spectrometers).
In practice, this is not achievable; instead, the values should be reported
and used in the retrieval work. This is due to the fact that (1) the use of
instrument-specific ILS parameters very likely does not cover all kinds of
possible instrumental imperfections and (2) the ILS description resulting
from the calibration procedure itself has limited accuracy.</p>
      <p id="d1e4626">This opens up a way to test for verifying progress made in the calibration
procedure; as such, progress is expected to make the resulting XGAS
calibration factors more uniform across different spectrometers. However,
the quality of the XCO calibration is limited by other factors not treated
in this work: the main impact factor being weak channelling in the spectra
(Blumenstock et al., 2021), because CO is a very weak absorber. In case of
<inline-formula><mml:math id="M182" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, we unfortunately face the drift of the reference spectrometer
calibration during the early years; see Sect. 6.1. Therefore, the instrument-specific <inline-formula><mml:math id="M183" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration factor appears to be the best available diagnostic. Table 5 provides the scatter of the gas-specific
calibration factor for <inline-formula><mml:math id="M184" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> between different spectrometers following
three different recipes: (1) assuming nominal ILS parameters, (2) using the
ILS parameters of the previous work by Frey et al. (2019) and (3) using the
ILS results obtained in this study. The numbers indicate that either method
developing instrument-specific ILS parameters delivers more consistent
calibration factors than the “nominal ILS” assumption, and the refined
calibration approach creates the least amount of scatter.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T5"><?xmltex \currentcnt{5}?><label>Table 5</label><caption><p id="d1e4665">Impact of ILS parameters on <inline-formula><mml:math id="M185" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration factors (this
statistic encompasses the subset of spectrometers that has been treated in
the study by Frey et al., 2019).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Procedure</oasis:entry>
         <oasis:entry colname="col2">Empirical standard deviation of</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M186" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration factors</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">between different spectrometers</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Nominal ILS</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M187" display="inline"><mml:mrow><mml:mn mathvariant="normal">9.49839</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">ILS results from</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M188" display="inline"><mml:mrow><mml:mn mathvariant="normal">8.56409</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Frey et al. (2019)</oasis:entry>
         <oasis:entry colname="col2"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">ILS results from this work</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M189" display="inline"><mml:mrow><mml:mn mathvariant="normal">7.16057</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
</sec>
<sec id="Ch1.S7" sec-type="conclusions">
  <label>7</label><title>Summary and outlook</title>
      <p id="d1e4821">The analysis of the open-path measurements for deriving the ILS parameters
of EM27/SUN FTIR spectrometers was improved, and all previous laboratory
open-path measurements for the determination of ILS parameters were
reanalysed. The revised empirical <inline-formula><mml:math id="M190" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> line list allows for a
significant reduction of fit residuals. The addition of a second spectral
window, which can be observed in both channels of the EM27/SUN spectrometer,
allows us to identify and quantify significant CO detector misalignments. We
recommend the application of this new refined procedure for characterizing
the ILS parameters of the EM27/SUN FTIR spectrometer from open-path
measurements.</p>
      <p id="d1e4837">In addition to the open-path measurements, a cell filled with <inline-formula><mml:math id="M191" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
was constructed and put into service. The cell measurement can be performed
in sequence with the open-path measurement without significant additional
effort. It offers similar sensitivity to the ILS parameters and adds redundancy
to the calibration process, and the <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> column is expected to be
invariant for all EM27/SUN spectrometers. We find an excellent agreement of
the retrieved column amount between different spectrometers (1-sigma scatter
on the order of 0.01 %; see Fig. 15c). Based
on these encouraging results, we plan to circulate <inline-formula><mml:math id="M193" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">C</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cells for
demonstrating the level of temporal stability of individual spectrometers
and the level of instrument-to-instrument consistency across the network.</p>
      <p id="d1e4888">The stability of the COCCON reference spectrometer was investigated, and
variations in <inline-formula><mml:math id="M194" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mtext>AIR</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> were found in the 2015–2017 period. This
variability has a non-negligible impact on the <inline-formula><mml:math id="M195" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration results
during this period of up to 0.14 %. All previous side-by-side measurements
reported by Frey et al. (2019) were reanalysed, using the revised ILS
parameters and incorporating the correction of the <inline-formula><mml:math id="M196" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> calibration
factors for the 2015–2017 period.</p>
      <p id="d1e4924">Forty-seven new spectrometers were calibrated before going into operation,
and several previously investigated spectrometers were recalibrated. The
resulting ILS parameters and empirical calibration factors for each target
gas are reported. We finally investigated the typical spectral SNR achieved
by the EM27/SUN spectrometer in solar and open-path measurements.</p>
      <p id="d1e4928">We notice a tendency towards improved, more consistent performance of recent
EM27/SUN spectrometers. We believe that the continued refinement and
continuous application of the quality assurance procedures performed by
COCCON in cooperation with the manufacturer of the spectrometers, Bruker,
support this tendency.</p><?xmltex \hack{\clearpage}?>
</sec>

      
      </body>
    <back><app-group>

<app id="App1.Ch1.S1">
  <?xmltex \currentcnt{A}?><label>Appendix A</label><title/>

      <?xmltex \floatpos{h!}?><fig id="App1.Ch1.S1.F27"><?xmltex \currentcnt{A1}?><?xmltex \def\figurename{Figure}?><label>Figure A1</label><caption><p id="d1e4944"><inline-formula><mml:math id="M197" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> spectroscopic lines used for this ILS calibration study.
The fits (multi-spectrum fit performed) using HITRAN 2016 and the new
empirical COCCON line list are presented in <bold>(a, b)</bold> and
<bold>(c, d)</bold>,
respectively. The measured spectra were taken with the IFS125HR at KIT
Karlsruhe, at 15 <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>. The spectral residuals shown are multiplied
by 5 in order to be visible.</p></caption>
        <?xmltex \hack{\hsize\textwidth}?>
        <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f27.png"/>

      </fig>

<?xmltex \hack{\clearpage}?><?xmltex \floatpos{h!}?><fig id="App1.Ch1.S1.F28"><?xmltex \currentcnt{A2}?><?xmltex \def\figurename{Figure}?><label>Figure A2</label><caption><p id="d1e4988">Same as Fig. A1, but the measured spectra were taken with the
IFS125HR at KIT Karlsruhe, at 30 <inline-formula><mml:math id="M199" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>.</p></caption>
        <?xmltex \hack{\hsize\textwidth}?>
        <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://amt.copernicus.org/articles/15/2433/2022/amt-15-2433-2022-f28.png"/>

      </fig>

</app>
  </app-group><notes notes-type="codeavailability"><title>Code availability</title>

      <p id="d1e5015">Linefit v14.8 used for the ILS characterization
can be obtained by contacting Frank Hase (frank.hase@kit.edu).
The PROFFAST software is freely available using the following link:
<uri>https://www.imk-asf.kit.edu/english/3225.php</uri> (last access: 14 April 2022; KIT-IMK-ASF, 2022).</p>
  </notes><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e5024">All the data used for this study can be directly
requested from the author: Carlos Alberti (carlos.alberti@kit.edu).</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e5027">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-15-2433-2022-supplement" xlink:title="pdf">https://doi.org/10.5194/amt-15-2433-2022-supplement</inline-supplementary-material>.<?xmltex \hack{\newpage}?></p></supplementary-material>
        </app-group><?xmltex \hack{~\\[133mm]}?><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e5039">CA and FH developed the experimental set-up
and data analysis procedures and carried out the measurements. CA performed
the data analysis and wrote the paper with support from FH. FH built
and calibrated the cell. MF performed the laboratory measurements from the
older instruments and proofread a previous version of the article. DD processed the EM27/SUN
spectrometer reference unit and the IFS125-LR data set. TB contributed to
the calibration effort, proofread and helped to improve the
paper. AD monitors, steers and regularly reviews the calibration
efforts undertaken for COCCON. GS and RH have contributed to the calibration
effort by helping to diagnose and solve any device problem found. JO has
continuously supported and encouraged the success of the COCCON project and
contributed to the calibration efforts and improving the paper. All
further co-authors collaborated on the calibration efforts and helped to
improve the paper.</p>
  </notes><?xmltex \hack{\newpage}?><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e5046">The contact author has declared that neither they nor their co-authors have any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e5052">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.</p>
  </notes><ack><title>Acknowledgement</title><p id="d1e5058">We thank Martin Kohler for providing the meteorological data sets from IMK-TRO's tower. Dragos Ene wants to acknowledge the Romanian National Core Program (contract no. 18N/2019) for funding his activities. Diogo J. Medeiros acknowledges the São Paulo Research Foundation (FAPESP) for financial support (grant 2019/27079-2). The Wollongong team want to acknowledge  the Australian Research Council (ARC) for supporting their activities under the grants DP160101598 and LE0668470.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e5063">This research has been supported by the European Space Agency (COCCON-PROCEEDS, grant no. 4000121212/17/I-EF; QA4EOQA4EO, grant no. 4000128426/19/NL/FF/ab; and FRM4GHG 2.0, grant no. 4000136108/21/I-DT-lr).<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>The article processing charges for this open-access <?xmltex \notforhtml{\newline}?>publication were covered by the Karlsruhe Institute<?xmltex \notforhtml{\newline}?> of Technology (KIT).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e5076">This paper was edited by Rebecca Washenfelder and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><?label 3?><mixed-citation>
Bernardo, C. and Griffith, D. W. T.: Fourier transform spectrometer instrument lineshape (ILS) retrieval by Fourier deconvolution, J. Quant. Spectrosc. Ra., 95, 141–150, 2005.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><?label 1?><mixed-citation>Blumenstock, T., Hase, F., Keens, A., Czurlok, D., Colebatch, O., Garcia, O., Griffith, D. W. T., Grutter, M., Hannigan, J. W., Heikkinen, P., Jeseck, P., Jones, N., Kivi, R., Lutsch, E., Makarova, M., Imhasin, H. K., Mellqvist, J., Morino, I., Nagahama, T., Notholt, J., Ortega, I., Palm, M., Raffalski, U., Rettinger, M., Robinson, J., Schneider, M., Servais, C., Smale, D., Stremme, W., Strong, K., Sussmann, R., Té, Y., and Velazco, V. A.: Characterization and potential for reducing optical resonances in Fourier transform infrared spectrometers of the Network for the Detection of Atmospheric Composition Change (NDACC), Atmos. Meas. Tech., 14, 1239–1252, <ext-link xlink:href="https://doi.org/10.5194/amt-14-1239-2021" ext-link-type="DOI">10.5194/amt-14-1239-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><?label 2?><mixed-citation>
Bruker: OPUS/IR Reference Manual version 7.0, Bruker Optik GmbH, Ettlingen,
2017.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><?label 2?><mixed-citation>Butz, A., Dinger, A. S., Bobrowski, N., Kostinek, J., Fieber, L., Fischerkeller, C., Giuffrida, G. B., Hase, F., Klappenbach, F., Kuhn, J., Lübcke, P., Tirpitz, L., and Tu, Q.: Remote sensing of volcanic CO<inline-formula><mml:math id="M200" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, HF, HCl, SO<inline-formula><mml:math id="M201" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, and BrO in the downwind plume of Mt. Etna, Atmos. Meas. Tech., 10, 1–14, <ext-link xlink:href="https://doi.org/10.5194/amt-10-1-2017" ext-link-type="DOI">10.5194/amt-10-1-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><?label 4?><mixed-citation>Chen, J., Viatte, C., Hedelius, J. K., Jones, T., Franklin, J. E., Parker, H., Gottlieb, E. W., Wennberg, P. O., Dubey, M. K., and Wofsy, S. C.: Differential column measurements using compact solar-tracking spectrometers, Atmos. Chem. Phys., 16, 8479–8498, <ext-link xlink:href="https://doi.org/10.5194/acp-16-8479-2016" ext-link-type="DOI">10.5194/acp-16-8479-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><?label 5?><mixed-citation>Chen, J., Dietrich, F., Maazallahi, H., Forstmaier, A., Winkler, D., Hofmann, M. E. G., Denier van der Gon, H., and Röckmann, T.: Methane emissions from the Munich Oktoberfest, Atmos. Chem. Phys., 20, 3683–3696, <ext-link xlink:href="https://doi.org/10.5194/acp-20-3683-2020" ext-link-type="DOI">10.5194/acp-20-3683-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><?label 7?><mixed-citation>Crisp, D., Pollock, H. R., Rosenberg, R., Chapsky, L., Lee, R. A. M., Oyafuso, F. A., Frankenberg, C., O'Dell, C. W., Bruegge, C. J., Doran, G. B., Eldering, A., Fisher, B. M., Fu, D., Gunson, M. R., Mandrake, L., Osterman, G. B., Schwandner, F. M., Sun, K., Taylor, T. E., Wennberg, P. O., and Wunch, D.: The on-orbit performance of the Orbiting Carbon Observatory-2 (OCO-2) instrument and its radiometrically calibrated products, Atmos. Meas. Tech., 10, 59–81, <ext-link xlink:href="https://doi.org/10.5194/amt-10-59-2017" ext-link-type="DOI">10.5194/amt-10-59-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><?label 6?><mixed-citation>Dietrich, F., Chen, J., Voggenreiter, B., Aigner, P., Nachtigall, N., and Reger, B.: MUCCnet: Munich Urban Carbon Column network, Atmos. Meas. Tech., 14, 1111–1126, <ext-link xlink:href="https://doi.org/10.5194/amt-14-1111-2021" ext-link-type="DOI">10.5194/amt-14-1111-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><?label 9?><mixed-citation>Drummond, J. R. and Mand, G. S.: The Measurements of Pollution in the Troposphere (MOPITT) Instrument: Overall Performance and Calibration Requirements, J. Atmos. Ocean. Tech., 13, 314–320, <ext-link xlink:href="https://doi.org/10.1175/1520-0426(1996)013&lt;0314:TMOPIT&gt;2.0.CO;2" ext-link-type="DOI">10.1175/1520-0426(1996)013&lt;0314:TMOPIT&gt;2.0.CO;2</ext-link>, 1996.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><?label 8?><mixed-citation>Drummond, J. R., Zou, J., Nichitiu, F., Kar, J., Deschambaut, R., and Hackett, J.: A review of 9-year performance and operation of the MOPITT instrument, Adv. Space Res., 45, 760–774, <ext-link xlink:href="https://doi.org/10.1016/j.asr.2009.11.019" ext-link-type="DOI">10.1016/j.asr.2009.11.019</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><?label 10?><mixed-citation>Eldering, A., O'Dell, C. W., Wennberg, P. O., Crisp, D., Gunson, M. R., Viatte, C., Avis, C., Braverman, A., Castano, R., Chang, A., Chapsky, L., Cheng, C., Connor, B., Dang, L., Doran, G., Fisher, B., Frankenberg, C., Fu, D., Granat, R., Hobbs, J., Lee, R. A. M., Mandrake, L., McDuffie, J., Miller, C. E., Myers, V., Natraj, V., O'Brien, D., Osterman, G. B., Oyafuso, F., Payne, V. H., Pollock, H. R., Polonsky, I., Roehl, C. M., Rosenberg, R., Schwandner, F., Smyth, M., Tang, V., Taylor, T. E., To, C., Wunch, D., and Yoshimizu, J.: The Orbiting Carbon Observatory-2: first 18 months of science data products, Atmos. Meas. Tech., 10, 549–563, <ext-link xlink:href="https://doi.org/10.5194/amt-10-549-2017" ext-link-type="DOI">10.5194/amt-10-549-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><?label 11?><mixed-citation>Eldering, A., Taylor, T. E., O'Dell, C. W., and Pavlick, R.: The OCO-3 mission: measurement objectives and expected performance based on 1 year of simulated data, Atmos. Meas. Tech., 12, 2341–2370, <ext-link xlink:href="https://doi.org/10.5194/amt-12-2341-2019" ext-link-type="DOI">10.5194/amt-12-2341-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><?label 12?><mixed-citation>Frankenberg, C., Pollock, R., Lee, R. A. M., Rosenberg, R., Blavier, J.-F., Crisp, D., O'Dell, C. W., Osterman, G. B., Roehl, C., Wennberg, P. O., and Wunch, D.: The Orbiting Carbon Observatory (OCO-2): spectrometer performance evaluation using pre-launch direct sun measurements, Atmos. Meas. Tech., 8, 301–313, <ext-link xlink:href="https://doi.org/10.5194/amt-8-301-2015" ext-link-type="DOI">10.5194/amt-8-301-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><?label 15?><mixed-citation>Frey, M., Hase, F., Blumenstock, T., Groß, J., Kiel, M., Mengistu Tsidu, G., Schäfer, K., Sha, M. K., and Orphal, J.: Calibration and instrumental line shape characterization of a set of portable FTIR spectrometers for detecting greenhouse gas emissions, Atmos. Meas. Tech., 8, 3047–3057, <ext-link xlink:href="https://doi.org/10.5194/amt-8-3047-2015" ext-link-type="DOI">10.5194/amt-8-3047-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><?label 13?><mixed-citation>Frey, M., Sha, M. K., Hase, F., Kiel, M., Blumenstock, T., Harig, R., Surawicz, G., Deutscher, N. M., Shiomi, K., Franklin, J. E., Bösch, H., Chen, J., Grutter, M., Ohyama, H., Sun, Y., Butz, A., Mengistu Tsidu, G., Ene, D., Wunch, D., Cao, Z., Garcia, O., Ramonet, M., Vogel, F., and Orphal, J.: Building the COllaborative Carbon Column Observing Network (COCCON): long-term stability and ensemble performance of the EM27/SUN Fourier transform spectrometer, Atmos. Meas. Tech., 12, 1513–1530, <ext-link xlink:href="https://doi.org/10.5194/amt-12-1513-2019" ext-link-type="DOI">10.5194/amt-12-1513-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><?label 15?><mixed-citation>Frey, M. M., Hase, F., Blumenstock, T., Dubravica, D., Groß, J., Göttsche, F., Handjaba, M., Amadhila, P., Mushi, R., Morino, I., Shiomi, K., Sha, M. K., de Mazière, M., and Pollard, D. F.: Long-term column-averaged greenhouse gas observations using a COCCON spectrometer at the high-surface-albedo site in Gobabeb, Namibia, Atmos. Meas. Tech., 14, 5887–5911, <ext-link xlink:href="https://doi.org/10.5194/amt-14-5887-2021" ext-link-type="DOI">10.5194/amt-14-5887-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><?label 16?><mixed-citation>Gisi, M., Hase, F., Dohe, S., Blumenstock, T., Simon, A., and Keens, A.: <inline-formula><mml:math id="M202" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>-measurements with a tabletop FTS using solar absorption spectroscopy, Atmos. Meas. Tech., 5, 2969–2980, <ext-link xlink:href="https://doi.org/10.5194/amt-5-2969-2012" ext-link-type="DOI">10.5194/amt-5-2969-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><?label 20?><mixed-citation>Hase, F.: Improved instrumental line shape monitoring for the ground-based, high-resolution FTIR spectrometers of the Network for the Detection of Atmospheric Composition Change, Atmos. Meas. Tech., 5, 603–610, <ext-link xlink:href="https://doi.org/10.5194/amt-5-603-2012" ext-link-type="DOI">10.5194/amt-5-603-2012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><?label 21?><mixed-citation>Hase, F., Blumenstock, T., and Paton-Walsh, C.: Analysis of the instrumental line shape of high-resolution Fourier transform IR spectrometers with gas cell measurements and new retrieval software, Appl. Opt., 38, 3417–3422, <ext-link xlink:href="https://doi.org/10.1364/AO.38.003417" ext-link-type="DOI">10.1364/AO.38.003417</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><?label 19?><mixed-citation>Hase, F., Drouin, B. J., Roehl, C. M., Toon, G. C., Wennberg, P. O., Wunch, D., Blumenstock, T., Desmet, F., Feist, D. G., Heikkinen, P., De Mazière, M., Rettinger, M., Robinson, J., Schneider, M., Sherlock, V., Sussmann, R., Té, Y., Warneke, T., and Weinzierl, C.: Calibration of sealed HCl cells used for TCCON instrumental line shape monitoring, Atmos. Meas. Tech., 6, 3527–3537, <ext-link xlink:href="https://doi.org/10.5194/amt-6-3527-2013" ext-link-type="DOI">10.5194/amt-6-3527-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><?label 18?><mixed-citation>Hase, F., Frey, M., Blumenstock, T., Groß, J., Kiel, M., Kohlhepp, R., Mengistu Tsidu, G., Schäfer, K., Sha, M. K., and Orphal, J.: Application of portable FTIR spectrometers for detecting greenhouse gas emissions of the major city Berlin, Atmos. Meas. Tech., 8, 3059–3068, <ext-link xlink:href="https://doi.org/10.5194/amt-8-3059-2015" ext-link-type="DOI">10.5194/amt-8-3059-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><?label 17?><mixed-citation>Hase, F., Frey, M., Kiel, M., Blumenstock, T., Harig, R., Keens, A., and Orphal, J.: Addition of a channel for XCO observations to a portable FTIR spectrometer for greenhouse gas measurements, Atmos. Meas. Tech., 9, 2303–2313, <ext-link xlink:href="https://doi.org/10.5194/amt-9-2303-2016" ext-link-type="DOI">10.5194/amt-9-2303-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><?label 22?><mixed-citation>Hedelius, J. K., Viatte, C., Wunch, D., Roehl, C. M., Toon, G. C., Chen, J., Jones, T., Wofsy, S. C., Franklin, J. E., Parker, H., Dubey, M. K., and Wennberg, P. O.: Assessment of errors and biases in retrievals of <inline-formula><mml:math id="M203" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M204" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M205" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mi mathvariant="normal">CO</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">X</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> from a 0.5 <inline-formula><mml:math id="M207" display="inline"><mml:mrow class="unit"><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> resolution solar-viewing spectrometer, Atmos. Meas. Tech., 9, 3527–3546, <ext-link xlink:href="https://doi.org/10.5194/amt-9-3527-2016" ext-link-type="DOI">10.5194/amt-9-3527-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><?label 32?><mixed-citation>
IPCC: Climate Change 2021: The Physical Science Basis. Contribution of Working Group I to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change, edited by: Masson-Delmotte, V., Zhai, P., Pirani, A., Connors, S. L., Péan, C., Berger, S., Caud, N., Chen, Y., Goldfarb, L., Gomis, M. I., Huang, M., Leitzell, K., Lonnoy, E., Matthews, J. B. R., Maycock, T. K., Waterfield, T., Yelekçi, O., Yu, R., and Zhou, B., Cambridge University Press, in press, 2021.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><?label 24?><mixed-citation>Jones, T. S., Franklin, J. E., Chen, J., Dietrich, F., Hajny, K. D., Paetzold, J. C., Wenzel, A., Gately, C., Gottlieb, E., Parker, H., Dubey, M., Hase, F., Shepson, P. B., Mielke, L. H., and Wofsy, S. C.: Assessing urban methane emissions using column-observing portable Fourier transform infrared (FTIR) spectrometers and a novel Bayesian inversion framework, Atmos. Chem. Phys., 21, 13131–13147, <ext-link xlink:href="https://doi.org/10.5194/acp-21-13131-2021" ext-link-type="DOI">10.5194/acp-21-13131-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><?label 23?><mixed-citation>
Kauppinen, J. and Saarinen, P.: Line-shape distortions in misaligned cube corner interferometers, Appl. Opt., 31, 69–74, 1992.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><?label 25?><mixed-citation>Kille, N., Chiu, R., Frey, M., Hase, F., Sha, M. K., Blumenstock, T., Hannigan, J. W., Orphal, J., Bon, D., and Volkamer, R.: Separation of Methane Emissions From Agricultural and Natural Gas Sources in the Colorado Front Range, Geophys. Res. Lett., 46, 3990–3998, <ext-link xlink:href="https://doi.org/10.1029/2019GL082132" ext-link-type="DOI">10.1029/2019GL082132</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><?label 25?><mixed-citation>KIT-IMK-ASF: PROFFAST software, Institute of Meteorology and Climate Research – Atmosphereic Trace Gases and Remote Sensing (IMK-ASF) [code], <uri>https://www.imk-asf.kit.edu/english/3225.php</uri>, last access: 14 April 2022.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><?label 26?><mixed-citation>Kohler, M., Metzger, J., and Kalthoff, N.: Trends in
temperature and wind speed from 40 years of observations at a 200 m
high meteorological tower in Southwest Germany, Int. J. Climatol.,
38, 23–34, <ext-link xlink:href="https://doi.org/10.1002/joc.5157" ext-link-type="DOI">10.1002/joc.5157</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><?label 27?><mixed-citation>Kuze, A., Suto, H., Nakajima, M., and Hamazaki, T.: Thermal and near infrared sensor for carbon observation Fourier-transform spectrometer on the Greenhouse Gases Observing Satellite for greenhouse gases monitoring, Appl. Opt., 48, 6716–6733, <ext-link xlink:href="https://doi.org/10.1364/AO.48.006716" ext-link-type="DOI">10.1364/AO.48.006716</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><?label 28?><mixed-citation>Liu, Y., Wang, J., Yao, L., Chen, X., Cai, Z., Yang, D., Yin, Z., Gu, S., Tian, L., Lu, N., and Lyu, D.: The TanSat mission:434 preliminary global observations, Sci. Bull., 63, 1200–1207, <ext-link xlink:href="https://doi.org/10.1016/j.scib.2018.08.004" ext-link-type="DOI">10.1016/j.scib.2018.08.004</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><?label 30?><mixed-citation>Luther, A., Kleinschek, R., Scheidweiler, L., Defratyka, S., Stanisavljevic, M., Forstmaier, A., Dandocsi, A., Wolff, S., Dubravica, D., Wildmann, N., Kostinek, J., Jöckel, P., Nickl, A.-L., Klausner, T., Hase, F., Frey, M., Chen, J., Dietrich, F., Nȩcki, J., Swolkień, J., Fix, A., Roiger, A., and Butz, A.: Quantifying <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> emissions from hard coal mines using mobile sun-viewing Fourier transform spectrometry, Atmos. Meas. Tech., 12, 5217–5230, <ext-link xlink:href="https://doi.org/10.5194/amt-12-5217-2019" ext-link-type="DOI">10.5194/amt-12-5217-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><?label 31?><mixed-citation>Makarova, M. V., Alberti, C., Ionov, D. V., Hase, F., Foka, S. C., Blumenstock, T., Warneke, T., Virolainen, Y. A., Kostsov, V. S., Frey, M., Poberovskii, A. V., Timofeyev, Y. M., Paramonova, N. N., Volkova, K. A., Zaitsev, N. A., Biryukov, E. Y., Osipov, S. I., Makarov, B. K., Polyakov, A. V., Ivakhov, V. M., Imhasin, H. Kh., and Mikhailov, E. F.: Emission Monitoring Mobile Experiment (EMME): an overview and first results of the St. Petersburg megacity campaign 2019, Atmos. Meas. Tech., 14, 1047–1073, <ext-link xlink:href="https://doi.org/10.5194/amt-14-1047-2021" ext-link-type="DOI">10.5194/amt-14-1047-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><?label 33?><mixed-citation>Morino, I., Uchino, O., Inoue, M., Yoshida, Y., Yokota, T., Wennberg, P. O., Toon, G. C., Wunch, D., Roehl, C. M., Notholt, J., Warneke, T., Messerschmidt, J., Griffith, D. W. T., Deutscher, N. M., Sherlock, V., Connor, B., Robinson, J., Sussmann, R., and Rettinger, M.: Preliminary validation of column-averaged volume mixing ratios of carbon dioxide and methane retrieved from GOSAT short-wavelength infrared spectra, Atmos. Meas. Tech., 4, 1061–1076, <ext-link xlink:href="https://doi.org/10.5194/amt-4-1061-2011" ext-link-type="DOI">10.5194/amt-4-1061-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><?label 34?><mixed-citation>Sha, M. K., De Mazière, M., Notholt, J., Blumenstock, T., Chen, H., Dehn, A., Griffith, D. W. T., Hase, F., Heikkinen, P., Hermans, C., Hoffmann, A., Huebner, M., Jones, N., Kivi, R., Langerock, B., Petri, C., Scolas, F., Tu, Q., and Weidmann, D.: Intercomparison of low- and high-resolution infrared spectrometers for ground-based solar remote sensing measurements of total column concentrations of <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and CO, Atmos. Meas. Tech., 13, 4791–4839, <ext-link xlink:href="https://doi.org/10.5194/amt-13-4791-2020" ext-link-type="DOI">10.5194/amt-13-4791-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><?label 35?><mixed-citation>Suto, H., Kataoka, F., Kikuchi, N., Knuteson, R. O., Butz, A., Haun, M., Buijs, H., Shiomi, K., Imai, H., and Kuze, A.: Thermal and near-infrared sensor for carbon observation Fourier transform spectrometer-2 (TANSO-FTS-2) on the Greenhouse gases Observing SATellite-2 (GOSAT-2) during its first year in orbit, Atmos. Meas. Tech., 14, 2013–2039, <ext-link xlink:href="https://doi.org/10.5194/amt-14-2013-2021" ext-link-type="DOI">10.5194/amt-14-2013-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><?label 36?><mixed-citation>Tu, Q.: Observation of atmospheric greenhouse gas abundances on regional scales in boreal areas using portable FTIR Spectrometers, Dissertation, Karlsruhe Institute for Technolgy (KIT), Germany, <ext-link xlink:href="https://doi.org/10.5445/IR/1000095901" ext-link-type="DOI">10.5445/IR/1000095901</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><?label 37?><mixed-citation>Veefkind, J. P., Aben, I., McMullan, K., Förster, H., de Vries, J., Otter, G., Claas, J., Eskes, H. J., de Haan, J. F., Kleipool, Q., van Weele, M., Hasekamp, O., Hoogeveen, R., Landgraf, J., Snel, R., Tol, P., Ingmann, P., Voors, R., Kruizinga, B., Vink, R., Visser, H., and Levelt, P. F.: TROPOMI on the ESA Sentinel-5 Precursor: A GMES mission for global observations of the atmospheric composition for climate, air quality and ozone layer applications, Remote Sens. Environ., 120, 70–83, <ext-link xlink:href="https://doi.org/10.1016/j.rse.2011.09.027" ext-link-type="DOI">10.1016/j.rse.2011.09.027</ext-link>, 2012.
</mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib39"><label>39</label><?label 38?><mixed-citation>Viatte, C., Lauvaux, T., Hedelius, J. K., Parker, H., Chen, J., Jones, T., Franklin, J. E., Deng, A. J., Gaudet, B., Verhulst, K., Duren, R., Wunch, D., Roehl, C., Dubey, M. K., Wofsy, S., and Wennberg, P. O.: Methane emissions from dairies in the Los Angeles Basin, Atmos. Chem. Phys., 17, 7509–7528, <ext-link xlink:href="https://doi.org/10.5194/acp-17-7509-2017" ext-link-type="DOI">10.5194/acp-17-7509-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><?label 39?><mixed-citation>Vogel, F. R., Frey, M., Staufer, J., Hase, F., Broquet, G., Xueref-Remy, I., Chevallier, F., Ciais, P., Sha, M. K., Chelin, P., Jeseck, P., Janssen, C., Té, Y., Groß, J., Blumenstock, T., Tu, Q., and Orphal, J.: <inline-formula><mml:math id="M211" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in an emission hot-spot region: the COCCON Paris campaign 2015, Atmos. Chem. Phys., 19, 3271–3285, <ext-link xlink:href="https://doi.org/10.5194/acp-19-3271-2019" ext-link-type="DOI">10.5194/acp-19-3271-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><?label 40?><mixed-citation>Wunch, D., Toon, G. C., Blavier, J.-F. L., Washenfelder, R. A., Notholt, J., Connor, B. J., Griffith, D. W. T., Sherlock, V., and Wennberg, P. O.: The Total Carbon Column Observing Network, Philos. T. Roy. Soc. A, 369, 2087–2112, <ext-link xlink:href="https://doi.org/10.1098/rsta.2010.0240" ext-link-type="DOI">10.1098/rsta.2010.0240</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><?label 41?><mixed-citation>Wunch, D., Toon, G., Sherlock, V., Deutscher, N. M., Liu, C., Feist, D. G., and Wennberg, P. O.: The Total Carbon Column Observing Network's GGG2014 Data Version, CaltechDATA [data set], <uri>https://doi.org/10.14291/tccon.ggg2014.documentation.R0/1221662</uri>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><?label 42?><mixed-citation>Yoshida, Y., Kikuchi, N., Morino, I., Uchino, O., Oshchepkov, S., Bril, A., Saeki, T., Schutgens, N., Toon, G. C., Wunch, D., Roehl, C. M., Wennberg, P. O., Griffith, D. W. T., Deutscher, N. M., Warneke, T., Notholt, J., Robinson, J., Sherlock, V., Connor, B., Rettinger, M., Sussmann, R., Ahonen, P., Heikkinen, P., Kyrö, E., Mendonca, J., Strong, K., Hase, F., Dohe, S., and Yokota, T.: Improvement of the retrieval algorithm for GOSAT SWIR <inline-formula><mml:math id="M212" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M213" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">XCH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and their validation using TCCON data, Atmos. Meas. Tech., 6, 1533–1547, <ext-link xlink:href="https://doi.org/10.5194/amt-6-1533-2013" ext-link-type="DOI">10.5194/amt-6-1533-2013</ext-link>, 2013.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Improved calibration procedures for the EM27/SUN spectrometers of the COllaborative Carbon Column Observing Network (COCCON)</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Bernardo, C. and Griffith, D. W. T.: Fourier transform spectrometer instrument lineshape (ILS) retrieval by Fourier deconvolution, J. Quant. Spectrosc. Ra., 95, 141–150, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Blumenstock, T., Hase, F., Keens, A., Czurlok, D., Colebatch, O., Garcia, O., Griffith, D. W. T., Grutter, M., Hannigan, J. W., Heikkinen, P., Jeseck, P., Jones, N., Kivi, R., Lutsch, E., Makarova, M., Imhasin, H. K., Mellqvist, J., Morino, I., Nagahama, T., Notholt, J., Ortega, I., Palm, M., Raffalski, U., Rettinger, M., Robinson, J., Schneider, M., Servais, C., Smale, D., Stremme, W., Strong, K., Sussmann, R., Té, Y., and Velazco, V. A.: Characterization and potential for reducing optical resonances in Fourier transform infrared spectrometers of the Network for the Detection of Atmospheric Composition Change (NDACC), Atmos. Meas. Tech., 14, 1239–1252, <a href="https://doi.org/10.5194/amt-14-1239-2021" target="_blank">https://doi.org/10.5194/amt-14-1239-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Bruker: OPUS/IR Reference Manual version 7.0, Bruker Optik GmbH, Ettlingen,
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Butz, A., Dinger, A. S., Bobrowski, N., Kostinek, J., Fieber, L., Fischerkeller, C., Giuffrida, G. B., Hase, F., Klappenbach, F., Kuhn, J., Lübcke, P., Tirpitz, L., and Tu, Q.: Remote sensing of volcanic CO<sub>2</sub>, HF, HCl, SO<sub>2</sub>, and BrO in the downwind plume of Mt. Etna, Atmos. Meas. Tech., 10, 1–14, <a href="https://doi.org/10.5194/amt-10-1-2017" target="_blank">https://doi.org/10.5194/amt-10-1-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Chen, J., Viatte, C., Hedelius, J. K., Jones, T., Franklin, J. E., Parker, H., Gottlieb, E. W., Wennberg, P. O., Dubey, M. K., and Wofsy, S. C.: Differential column measurements using compact solar-tracking spectrometers, Atmos. Chem. Phys., 16, 8479–8498, <a href="https://doi.org/10.5194/acp-16-8479-2016" target="_blank">https://doi.org/10.5194/acp-16-8479-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Chen, J., Dietrich, F., Maazallahi, H., Forstmaier, A., Winkler, D., Hofmann, M. E. G., Denier van der Gon, H., and Röckmann, T.: Methane emissions from the Munich Oktoberfest, Atmos. Chem. Phys., 20, 3683–3696, <a href="https://doi.org/10.5194/acp-20-3683-2020" target="_blank">https://doi.org/10.5194/acp-20-3683-2020</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Crisp, D., Pollock, H. R., Rosenberg, R., Chapsky, L., Lee, R. A. M., Oyafuso, F. A., Frankenberg, C., O'Dell, C. W., Bruegge, C. J., Doran, G. B., Eldering, A., Fisher, B. M., Fu, D., Gunson, M. R., Mandrake, L., Osterman, G. B., Schwandner, F. M., Sun, K., Taylor, T. E., Wennberg, P. O., and Wunch, D.: The on-orbit performance of the Orbiting Carbon Observatory-2 (OCO-2) instrument and its radiometrically calibrated products, Atmos. Meas. Tech., 10, 59–81, <a href="https://doi.org/10.5194/amt-10-59-2017" target="_blank">https://doi.org/10.5194/amt-10-59-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Dietrich, F., Chen, J., Voggenreiter, B., Aigner, P., Nachtigall, N., and Reger, B.: MUCCnet: Munich Urban Carbon Column network, Atmos. Meas. Tech., 14, 1111–1126, <a href="https://doi.org/10.5194/amt-14-1111-2021" target="_blank">https://doi.org/10.5194/amt-14-1111-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Drummond, J. R. and Mand, G. S.: The Measurements of Pollution in the Troposphere (MOPITT) Instrument: Overall Performance and Calibration Requirements, J. Atmos. Ocean. Tech., 13, 314–320, <a href="https://doi.org/10.1175/1520-0426(1996)013&lt;0314:TMOPIT&gt;2.0.CO;2" target="_blank">https://doi.org/10.1175/1520-0426(1996)013&lt;0314:TMOPIT&gt;2.0.CO;2</a>, 1996.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Drummond, J. R., Zou, J., Nichitiu, F., Kar, J., Deschambaut, R., and Hackett, J.: A review of 9-year performance and operation of the MOPITT instrument, Adv. Space Res., 45, 760–774, <a href="https://doi.org/10.1016/j.asr.2009.11.019" target="_blank">https://doi.org/10.1016/j.asr.2009.11.019</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Eldering, A., O'Dell, C. W., Wennberg, P. O., Crisp, D., Gunson, M. R., Viatte, C., Avis, C., Braverman, A., Castano, R., Chang, A., Chapsky, L., Cheng, C., Connor, B., Dang, L., Doran, G., Fisher, B., Frankenberg, C., Fu, D., Granat, R., Hobbs, J., Lee, R. A. M., Mandrake, L., McDuffie, J., Miller, C. E., Myers, V., Natraj, V., O'Brien, D., Osterman, G. B., Oyafuso, F., Payne, V. H., Pollock, H. R., Polonsky, I., Roehl, C. M., Rosenberg, R., Schwandner, F., Smyth, M., Tang, V., Taylor, T. E., To, C., Wunch, D., and Yoshimizu, J.: The Orbiting Carbon Observatory-2: first 18 months of science data products, Atmos. Meas. Tech., 10, 549–563, <a href="https://doi.org/10.5194/amt-10-549-2017" target="_blank">https://doi.org/10.5194/amt-10-549-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Eldering, A., Taylor, T. E., O'Dell, C. W., and Pavlick, R.: The OCO-3 mission: measurement objectives and expected performance based on 1 year of simulated data, Atmos. Meas. Tech., 12, 2341–2370, <a href="https://doi.org/10.5194/amt-12-2341-2019" target="_blank">https://doi.org/10.5194/amt-12-2341-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Frankenberg, C., Pollock, R., Lee, R. A. M., Rosenberg, R., Blavier, J.-F., Crisp, D., O'Dell, C. W., Osterman, G. B., Roehl, C., Wennberg, P. O., and Wunch, D.: The Orbiting Carbon Observatory (OCO-2): spectrometer performance evaluation using pre-launch direct sun measurements, Atmos. Meas. Tech., 8, 301–313, <a href="https://doi.org/10.5194/amt-8-301-2015" target="_blank">https://doi.org/10.5194/amt-8-301-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Frey, M., Hase, F., Blumenstock, T., Groß, J., Kiel, M., Mengistu Tsidu, G., Schäfer, K., Sha, M. K., and Orphal, J.: Calibration and instrumental line shape characterization of a set of portable FTIR spectrometers for detecting greenhouse gas emissions, Atmos. Meas. Tech., 8, 3047–3057, <a href="https://doi.org/10.5194/amt-8-3047-2015" target="_blank">https://doi.org/10.5194/amt-8-3047-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Frey, M., Sha, M. K., Hase, F., Kiel, M., Blumenstock, T., Harig, R., Surawicz, G., Deutscher, N. M., Shiomi, K., Franklin, J. E., Bösch, H., Chen, J., Grutter, M., Ohyama, H., Sun, Y., Butz, A., Mengistu Tsidu, G., Ene, D., Wunch, D., Cao, Z., Garcia, O., Ramonet, M., Vogel, F., and Orphal, J.: Building the COllaborative Carbon Column Observing Network (COCCON): long-term stability and ensemble performance of the EM27/SUN Fourier transform spectrometer, Atmos. Meas. Tech., 12, 1513–1530, <a href="https://doi.org/10.5194/amt-12-1513-2019" target="_blank">https://doi.org/10.5194/amt-12-1513-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Frey, M. M., Hase, F., Blumenstock, T., Dubravica, D., Groß, J., Göttsche, F., Handjaba, M., Amadhila, P., Mushi, R., Morino, I., Shiomi, K., Sha, M. K., de Mazière, M., and Pollard, D. F.: Long-term column-averaged greenhouse gas observations using a COCCON spectrometer at the high-surface-albedo site in Gobabeb, Namibia, Atmos. Meas. Tech., 14, 5887–5911, <a href="https://doi.org/10.5194/amt-14-5887-2021" target="_blank">https://doi.org/10.5194/amt-14-5887-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Gisi, M., Hase, F., Dohe, S., Blumenstock, T., Simon, A., and Keens, A.: XCO<sub>2</sub>-measurements with a tabletop FTS using solar absorption spectroscopy, Atmos. Meas. Tech., 5, 2969–2980, <a href="https://doi.org/10.5194/amt-5-2969-2012" target="_blank">https://doi.org/10.5194/amt-5-2969-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Hase, F.: Improved instrumental line shape monitoring for the ground-based, high-resolution FTIR spectrometers of the Network for the Detection of Atmospheric Composition Change, Atmos. Meas. Tech., 5, 603–610, <a href="https://doi.org/10.5194/amt-5-603-2012" target="_blank">https://doi.org/10.5194/amt-5-603-2012</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Hase, F., Blumenstock, T., and Paton-Walsh, C.: Analysis of the instrumental line shape of high-resolution Fourier transform IR spectrometers with gas cell measurements and new retrieval software, Appl. Opt., 38, 3417–3422, <a href="https://doi.org/10.1364/AO.38.003417" target="_blank">https://doi.org/10.1364/AO.38.003417</a>, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Hase, F., Drouin, B. J., Roehl, C. M., Toon, G. C., Wennberg, P. O., Wunch, D., Blumenstock, T., Desmet, F., Feist, D. G., Heikkinen, P., De Mazière, M., Rettinger, M., Robinson, J., Schneider, M., Sherlock, V., Sussmann, R., Té, Y., Warneke, T., and Weinzierl, C.: Calibration of sealed HCl cells used for TCCON instrumental line shape monitoring, Atmos. Meas. Tech., 6, 3527–3537, <a href="https://doi.org/10.5194/amt-6-3527-2013" target="_blank">https://doi.org/10.5194/amt-6-3527-2013</a>, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Hase, F., Frey, M., Blumenstock, T., Groß, J., Kiel, M., Kohlhepp, R., Mengistu Tsidu, G., Schäfer, K., Sha, M. K., and Orphal, J.: Application of portable FTIR spectrometers for detecting greenhouse gas emissions of the major city Berlin, Atmos. Meas. Tech., 8, 3059–3068, <a href="https://doi.org/10.5194/amt-8-3059-2015" target="_blank">https://doi.org/10.5194/amt-8-3059-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Hase, F., Frey, M., Kiel, M., Blumenstock, T., Harig, R., Keens, A., and Orphal, J.: Addition of a channel for XCO observations to a portable FTIR spectrometer for greenhouse gas measurements, Atmos. Meas. Tech., 9, 2303–2313, <a href="https://doi.org/10.5194/amt-9-2303-2016" target="_blank">https://doi.org/10.5194/amt-9-2303-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation> Hedelius, J. K., Viatte, C., Wunch, D., Roehl, C. M., Toon, G. C., Chen, J., Jones, T., Wofsy, S. C., Franklin, J. E., Parker, H., Dubey, M. K., and Wennberg, P. O.: Assessment of errors and biases in retrievals of X<sub>CO<sub>2</sub></sub>, X<sub>CH<sub>4</sub></sub>, X<sub>CO</sub>, and X<sub>N<sub>2</sub>O</sub> from a 0.5&thinsp;cm<sup>−1</sup> resolution solar-viewing spectrometer, Atmos. Meas. Tech., 9, 3527–3546, <a href="https://doi.org/10.5194/amt-9-3527-2016" target="_blank">https://doi.org/10.5194/amt-9-3527-2016</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
IPCC: Climate Change 2021: The Physical Science Basis. Contribution of Working Group I to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change, edited by: Masson-Delmotte, V., Zhai, P., Pirani, A., Connors, S. L., Péan, C., Berger, S., Caud, N., Chen, Y., Goldfarb, L., Gomis, M. I., Huang, M., Leitzell, K., Lonnoy, E., Matthews, J. B. R., Maycock, T. K., Waterfield, T., Yelekçi, O., Yu, R., and Zhou, B., Cambridge University Press, in press, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Jones, T. S., Franklin, J. E., Chen, J., Dietrich, F., Hajny, K. D., Paetzold, J. C., Wenzel, A., Gately, C., Gottlieb, E., Parker, H., Dubey, M., Hase, F., Shepson, P. B., Mielke, L. H., and Wofsy, S. C.: Assessing urban methane emissions using column-observing portable Fourier transform infrared (FTIR) spectrometers and a novel Bayesian inversion framework, Atmos. Chem. Phys., 21, 13131–13147, <a href="https://doi.org/10.5194/acp-21-13131-2021" target="_blank">https://doi.org/10.5194/acp-21-13131-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Kauppinen, J. and Saarinen, P.: Line-shape distortions in misaligned cube corner interferometers, Appl. Opt., 31, 69–74, 1992.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Kille, N., Chiu, R., Frey, M., Hase, F., Sha, M. K., Blumenstock, T., Hannigan, J. W., Orphal, J., Bon, D., and Volkamer, R.: Separation of Methane Emissions From Agricultural and Natural Gas Sources in the Colorado Front Range, Geophys. Res. Lett., 46, 3990–3998, <a href="https://doi.org/10.1029/2019GL082132" target="_blank">https://doi.org/10.1029/2019GL082132</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
KIT-IMK-ASF: PROFFAST software, Institute of Meteorology and Climate Research – Atmosphereic Trace Gases and Remote Sensing (IMK-ASF) [code], <a href="https://www.imk-asf.kit.edu/english/3225.php" target="_blank"/>, last access: 14 April 2022.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Kohler, M., Metzger, J., and Kalthoff, N.: Trends in
temperature and wind speed from 40 years of observations at a 200&thinsp;m
high meteorological tower in Southwest Germany, Int. J. Climatol.,
38, 23–34, <a href="https://doi.org/10.1002/joc.5157" target="_blank">https://doi.org/10.1002/joc.5157</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation> Kuze, A., Suto, H., Nakajima, M., and Hamazaki, T.: Thermal and near infrared sensor for carbon observation Fourier-transform spectrometer on the Greenhouse Gases Observing Satellite for greenhouse gases monitoring, Appl. Opt., 48, 6716–6733, <a href="https://doi.org/10.1364/AO.48.006716" target="_blank">https://doi.org/10.1364/AO.48.006716</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation> Liu, Y., Wang, J., Yao, L., Chen, X., Cai, Z., Yang, D., Yin, Z., Gu, S., Tian, L., Lu, N., and Lyu, D.: The TanSat mission:434 preliminary global observations, Sci. Bull., 63, 1200–1207, <a href="https://doi.org/10.1016/j.scib.2018.08.004" target="_blank">https://doi.org/10.1016/j.scib.2018.08.004</a>, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation> Luther, A., Kleinschek, R., Scheidweiler, L., Defratyka, S., Stanisavljevic, M., Forstmaier, A., Dandocsi, A., Wolff, S., Dubravica, D., Wildmann, N., Kostinek, J., Jöckel, P., Nickl, A.-L., Klausner, T., Hase, F., Frey, M., Chen, J., Dietrich, F., Nȩcki, J., Swolkień, J., Fix, A., Roiger, A., and Butz, A.: Quantifying CH<sub>4</sub> emissions from hard coal mines using mobile sun-viewing Fourier transform spectrometry, Atmos. Meas. Tech., 12, 5217–5230, <a href="https://doi.org/10.5194/amt-12-5217-2019" target="_blank">https://doi.org/10.5194/amt-12-5217-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation> Makarova, M. V., Alberti, C., Ionov, D. V., Hase, F., Foka, S. C., Blumenstock, T., Warneke, T., Virolainen, Y. A., Kostsov, V. S., Frey, M., Poberovskii, A. V., Timofeyev, Y. M., Paramonova, N. N., Volkova, K. A., Zaitsev, N. A., Biryukov, E. Y., Osipov, S. I., Makarov, B. K., Polyakov, A. V., Ivakhov, V. M., Imhasin, H. Kh., and Mikhailov, E. F.: Emission Monitoring Mobile Experiment (EMME): an overview and first results of the St. Petersburg megacity campaign 2019, Atmos. Meas. Tech., 14, 1047–1073, <a href="https://doi.org/10.5194/amt-14-1047-2021" target="_blank">https://doi.org/10.5194/amt-14-1047-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation> Morino, I., Uchino, O., Inoue, M., Yoshida, Y., Yokota, T., Wennberg, P. O., Toon, G. C., Wunch, D., Roehl, C. M., Notholt, J., Warneke, T., Messerschmidt, J., Griffith, D. W. T., Deutscher, N. M., Sherlock, V., Connor, B., Robinson, J., Sussmann, R., and Rettinger, M.: Preliminary validation of column-averaged volume mixing ratios of carbon dioxide and methane retrieved from GOSAT short-wavelength infrared spectra, Atmos. Meas. Tech., 4, 1061–1076, <a href="https://doi.org/10.5194/amt-4-1061-2011" target="_blank">https://doi.org/10.5194/amt-4-1061-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation> Sha, M. K., De Mazière, M., Notholt, J., Blumenstock, T., Chen, H., Dehn, A., Griffith, D. W. T., Hase, F., Heikkinen, P., Hermans, C., Hoffmann, A., Huebner, M., Jones, N., Kivi, R., Langerock, B., Petri, C., Scolas, F., Tu, Q., and Weidmann, D.: Intercomparison of low- and high-resolution infrared spectrometers for ground-based solar remote sensing measurements of total column concentrations of CO<sub>2</sub>, CH<sub>4</sub>, and CO, Atmos. Meas. Tech., 13, 4791–4839, <a href="https://doi.org/10.5194/amt-13-4791-2020" target="_blank">https://doi.org/10.5194/amt-13-4791-2020</a>, 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation> Suto, H., Kataoka, F., Kikuchi, N., Knuteson, R. O., Butz, A., Haun, M., Buijs, H., Shiomi, K., Imai, H., and Kuze, A.: Thermal and near-infrared sensor for carbon observation Fourier transform spectrometer-2 (TANSO-FTS-2) on the Greenhouse gases Observing SATellite-2 (GOSAT-2) during its first year in orbit, Atmos. Meas. Tech., 14, 2013–2039, <a href="https://doi.org/10.5194/amt-14-2013-2021" target="_blank">https://doi.org/10.5194/amt-14-2013-2021</a>, 2021.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation> Tu, Q.: Observation of atmospheric greenhouse gas abundances on regional scales in boreal areas using portable FTIR Spectrometers, Dissertation, Karlsruhe Institute for Technolgy (KIT), Germany, <a href="https://doi.org/10.5445/IR/1000095901" target="_blank">https://doi.org/10.5445/IR/1000095901</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation> Veefkind, J. P., Aben, I., McMullan, K., Förster, H., de Vries, J., Otter, G., Claas, J., Eskes, H. J., de Haan, J. F., Kleipool, Q., van Weele, M., Hasekamp, O., Hoogeveen, R., Landgraf, J., Snel, R., Tol, P., Ingmann, P., Voors, R., Kruizinga, B., Vink, R., Visser, H., and Levelt, P. F.: TROPOMI on the ESA Sentinel-5 Precursor: A GMES mission for global observations of the atmospheric composition for climate, air quality and ozone layer applications, Remote Sens. Environ., 120, 70–83, <a href="https://doi.org/10.1016/j.rse.2011.09.027" target="_blank">https://doi.org/10.1016/j.rse.2011.09.027</a>, 2012.

</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation> Viatte, C., Lauvaux, T., Hedelius, J. K., Parker, H., Chen, J., Jones, T., Franklin, J. E., Deng, A. J., Gaudet, B., Verhulst, K., Duren, R., Wunch, D., Roehl, C., Dubey, M. K., Wofsy, S., and Wennberg, P. O.: Methane emissions from dairies in the Los Angeles Basin, Atmos. Chem. Phys., 17, 7509–7528, <a href="https://doi.org/10.5194/acp-17-7509-2017" target="_blank">https://doi.org/10.5194/acp-17-7509-2017</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation> Vogel, F. R., Frey, M., Staufer, J., Hase, F., Broquet, G., Xueref-Remy, I., Chevallier, F., Ciais, P., Sha, M. K., Chelin, P., Jeseck, P., Janssen, C., Té, Y., Groß, J., Blumenstock, T., Tu, Q., and Orphal, J.: XCO<sub>2</sub> in an emission hot-spot region: the COCCON Paris campaign 2015, Atmos. Chem. Phys., 19, 3271–3285, <a href="https://doi.org/10.5194/acp-19-3271-2019" target="_blank">https://doi.org/10.5194/acp-19-3271-2019</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation> Wunch, D., Toon, G. C., Blavier, J.-F. L., Washenfelder, R. A., Notholt, J., Connor, B. J., Griffith, D. W. T., Sherlock, V., and Wennberg, P. O.: The Total Carbon Column Observing Network, Philos. T. Roy. Soc. A, 369, 2087–2112, <a href="https://doi.org/10.1098/rsta.2010.0240" target="_blank">https://doi.org/10.1098/rsta.2010.0240</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Wunch, D., Toon, G., Sherlock, V., Deutscher, N. M., Liu, C., Feist, D. G., and Wennberg, P. O.: The Total Carbon Column Observing Network's GGG2014 Data Version, CaltechDATA [data set], <a href="https://doi.org/10.14291/tccon.ggg2014.documentation.R0/1221662" target="_blank"/>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation> Yoshida, Y., Kikuchi, N., Morino, I., Uchino, O., Oshchepkov, S., Bril, A., Saeki, T., Schutgens, N., Toon, G. C., Wunch, D., Roehl, C. M., Wennberg, P. O., Griffith, D. W. T., Deutscher, N. M., Warneke, T., Notholt, J., Robinson, J., Sherlock, V., Connor, B., Rettinger, M., Sussmann, R., Ahonen, P., Heikkinen, P., Kyrö, E., Mendonca, J., Strong, K., Hase, F., Dohe, S., and Yokota, T.: Improvement of the retrieval algorithm for GOSAT SWIR XCO<sub>2</sub> and XCH<sub>4</sub> and their validation using TCCON data, Atmos. Meas. Tech., 6, 1533–1547, <a href="https://doi.org/10.5194/amt-6-1533-2013" target="_blank">https://doi.org/10.5194/amt-6-1533-2013</a>, 2013.
</mixed-citation></ref-html>--></article>
