<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article"><?xmltex \makeatother\@nolinetrue\makeatletter?>
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-17-1419-2024</article-id><title-group><article-title>Polarization upgrade of specMACS: calibration and characterization of the 2D RGB  polarization-resolving cameras</article-title><alt-title>Calibration of the polarization-resolving cameras of specMACS</alt-title>
      </title-group><?xmltex \runningtitle{Calibration of the polarization-resolving cameras of specMACS}?><?xmltex \runningauthor{A. Weber et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Weber</surname><given-names>Anna</given-names></name>
          <email>weber.ann@physik.uni-muenchen.de</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff3">
          <name><surname>Kölling</surname><given-names>Tobias</given-names></name>
          
        <ext-link>https://orcid.org/0009-0007-8742-2706</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Pörtge</surname><given-names>Veronika</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9019-6294</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Baumgartner</surname><given-names>Andreas</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-8495-5407</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2 aff4">
          <name><surname>Rammeloo</surname><given-names>Clemens</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2454-1306</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Zinner</surname><given-names>Tobias</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Mayer</surname><given-names>Bernhard</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Meteorologisches Institut, Ludwig-Maximilians-Universität München, Munich, Germany</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Deutsches Zentrum für Luft- und Raumfahrt, Institut für Methodik der Fernerkundung, Oberpfaffenhofen, Germany</institution>
        </aff>
        <aff id="aff3"><label>a</label><institution>now at: Max Planck Institute for Meteorology, Hamburg, Germany</institution>
        </aff>
        <aff id="aff4"><label>b</label><institution>now at: National Physical Laboratory, Teddington, United Kingdom</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Anna Weber (weber.ann@physik.uni-muenchen.de)</corresp></author-notes><pub-date><day>7</day><month>March</month><year>2024</year></pub-date>
      
      <volume>17</volume>
      <issue>5</issue>
      <fpage>1419</fpage><lpage>1439</lpage>
      <history>
        <date date-type="received"><day>27</day><month>September</month><year>2023</year></date>
           <date date-type="rev-request"><day>1</day><month>November</month><year>2023</year></date>
           <date date-type="rev-recd"><day>17</day><month>January</month><year>2024</year></date>
           <date date-type="accepted"><day>19</day><month>January</month><year>2024</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2024 Anna Weber et al.</copyright-statement>
        <copyright-year>2024</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024.html">This article is available from https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d1e155">The spectrometer of the Munich Aerosol Cloud Scanner (specMACS) is a high-spatial-resolution hyperspectral and polarized imaging system. It is operated from a nadir-looking perspective aboard the German <italic>High Altitude and LOng range</italic> (<italic>HALO</italic>) research aircraft and is mainly used for the remote sensing of clouds. In 2019, its two hyperspectral line cameras, which are sensitive to the wavelength range between 400 and 2500 nm, were complemented by two 2D RGB polarization-resolving cameras. The polarization-resolving cameras have a large field of view and allow for multi-angle polarimetric imaging with high angular and spatial resolution. This paper introduces the polarization-resolving cameras and provides a full characterization and calibration of them. We performed a geometric calibration and georeferencing of the two cameras. In addition, a radiometric calibration using laboratory calibration measurements was carried out. The radiometric calibration includes the characterization of the dark signal, linearity, and noise as well as the measurement of the spectral response functions, a polarization calibration, vignetting correction, and absolute radiometric calibration. With the calibration, georeferenced, absolute calibrated Stokes vectors rotated into the scattering plane can be computed from raw data. We validated the calibration results by comparing observations of the sunglint, which is a known target, with radiative transfer simulations of the sunglint.</p>
  </abstract>
    
<funding-group>
<award-group id="gs1">
<funding-source>Deutsche Forschungsgemeinschaft</funding-source>
<award-id>442667104</award-id>
</award-group>
</funding-group>
</article-meta>
  </front>
<body>
      

      <?xmltex \hack{\newpage}?>
<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e175">The remote sensing of clouds and aerosols with polarization measurements has been a very active field of research over the past years. Polarized radiance has the advantage that it is dominated by single scattering <xref ref-type="bibr" rid="bib1.bibx33" id="paren.1"/> and the contribution from multiple scattering is filtered out. Hence, retrievals based on polarization measurements are less influenced by 3D radiative effects compared to conventional spectral approaches. Multi-angle polarimetric observations allow for improved retrievals and contain additional polarization information which can be used for new retrievals. For example, <xref ref-type="bibr" rid="bib1.bibx30" id="text.2"/> and <xref ref-type="bibr" rid="bib1.bibx56" id="text.3"/> developed retrievals of the cloud thermodynamic phase from multi-angle polarimetric observations. Moreover, ice crystal asymmetry was derived from polarization by <xref ref-type="bibr" rid="bib1.bibx63" id="text.4"/>, and retrievals of cloud droplet size distribution from cloudbow observations have been developed by <xref ref-type="bibr" rid="bib1.bibx7" id="text.5"/>, <xref ref-type="bibr" rid="bib1.bibx1" id="text.6"/>, <xref ref-type="bibr" rid="bib1.bibx48" id="text.7"/>, and <xref ref-type="bibr" rid="bib1.bibx52" id="text.8"/> to name a few examples for retrievals of cloud properties from polarization measurements. Besides that, polarization measurements have also been used to derive aerosol properties <xref ref-type="bibr" rid="bib1.bibx16" id="paren.9"/>.</p>
      <p id="d1e206">There are a number of spaceborne and airborne remote sensing instruments with polarization capabilities such as the POLDER instrument <xref ref-type="bibr" rid="bib1.bibx13" id="paren.10"/>, RSP <xref ref-type="bibr" rid="bib1.bibx8" id="paren.11"/>, AirHARP <xref ref-type="bibr" rid="bib1.bibx45" id="paren.12"/>, SPEX airborne <xref ref-type="bibr" rid="bib1.bibx58" id="paren.13"/>, and AirMSPI <?pagebreak page1420?><xref ref-type="bibr" rid="bib1.bibx14" id="paren.14"/> which have successfully applied various polarization-based retrievals. The spectrometer of the Munich Aerosol Cloud Scanner (specMACS) originally consisted of two hyperspectral cameras in the visible and near-infrared wavelength range <xref ref-type="bibr" rid="bib1.bibx22" id="paren.15"/>. Data of the hyperspectral cameras have for example been used to retrieve profiles of the cloud droplet effective radius <xref ref-type="bibr" rid="bib1.bibx23" id="paren.16"/> and cloud geometry from oxygen-A-band observations <xref ref-type="bibr" rid="bib1.bibx67" id="paren.17"/>. Before the EUREC<inline-formula><mml:math id="M1" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A field campaign <xref ref-type="bibr" rid="bib1.bibx60" id="paren.18"/> in 2019, they were complemented by two 2D RGB polarization-resolving cameras with a large field of view and high angular and spatial resolution. With that, specMACS became a hyperspectral and polarized imaging system. Hyperspectral and polarization-resolving cameras are operated on the same platform, allowing for combined and improved retrievals of cloud properties. In this paper, the polarization-resolving cameras will be introduced.</p>
      <p id="d1e246">In general, any digital imaging sensor has imperfections and non-uniformities due to manufacturing and sensor electronics, which have to be assessed and characterized by calibration. In addition, an absolute calibration is necessary for certain retrievals. The polarization-resolving cameras of specMACS can be classified as division-of-focal-plane polarimeters. There are a variety of different calibration techniques for division-of-focal-plane polarimeters, which have been reviewed by <xref ref-type="bibr" rid="bib1.bibx28 bib1.bibx29" id="text.19"/>. <xref ref-type="bibr" rid="bib1.bibx43" id="text.20"/> for example calibrated the monochrome version of the polarization-resolving cameras from the same manufacturer as our cameras; however they did not provide an absolute calibration. <xref ref-type="bibr" rid="bib1.bibx57" id="text.21"/> calibrated a camera with the same sensor, but the assumptions they made are not applicable to the specific instrument setup of specMACS, since the specMACS setup includes not only lenses but also a window in front of the cameras. We performed a complete characterization and calibration of the polarization-resolving cameras with a geometric calibration as well as a radiometric calibration. The radiometric calibration includes a dark-signal and noise characterization, a linearity analysis, vignetting correction, polarization calibration, spectral calibration, and absolute radiometric calibration. With that, we can compute georeferenced, absolute calibrated Stokes vectors, which are rotated into the scattering plane. Here, the scattering plane is the plane containing the direction of the incoming solar radiation and the viewing direction for every pixel. We completed the calibration measurements at the Calibration Home Base <xref ref-type="bibr" rid="bib1.bibx15" id="paren.22"/> and present our calibration methods and results in this paper. Finally, we applied the calibration results to measurement data of the sunglint, which is formed by the reflection of sunlight on water surfaces. The sunglint is a known target, so we could validate the calibration results by comparing the calibrated measurements with radiative transfer simulations of the sunglint.</p>
      <p id="d1e261">The paper is organized as follows. First, an instrument description is given, followed by the geometric calibration methods and results in Sect. <xref ref-type="sec" rid="Ch1.S3"/> and the radiometric calibration of the polarization-resolving cameras in Sect. <xref ref-type="sec" rid="Ch1.S4"/>. In Sect. <xref ref-type="sec" rid="Ch1.S5"/>, the calibration is applied to measurement data and compared with radiative transfer simulations of the sunglint in order to validate the calibration. Finally, the results are summed up.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Instrument description</title>
      <p id="d1e278">The spectrometer of the Munich Aerosol Cloud Scanner (specMACS) is a hyperspectral and polarized imaging system developed and operated by the Meteorological Institute of the Ludwig-Maximilians-Universität München <xref ref-type="bibr" rid="bib1.bibx22" id="paren.23"/>. It is mainly used for the remote sensing of cloud macro- and microphysical properties.</p>
      <p id="d1e284">Originally, specMACS consisted of two hyperspectral cameras, so-called VNIR and SWIR, which are sensitive to the wavelength range from 400 to 1000 and from 1000 to 2500 nm, respectively. Both cameras were characterized and calibrated by <xref ref-type="bibr" rid="bib1.bibx22" id="text.24"/> for the first time in 2014. Together with the calibration of the polarization-resolving cameras in 2021, the calibration of the VNIR camera was repeated and showed no changes beyond the measurement uncertainties. The calibration measurements of the SWIR camera could not be repeated in 2021, since the camera had to be sent to the manufacturer for repair.</p>
      <p id="d1e290">In the past, specMACS was operated in a ground-based setup before it was integrated into the German <italic>High Altitude and LOng range</italic> (<italic>HALO</italic>) research aircraft <xref ref-type="bibr" rid="bib1.bibx42" id="paren.25"/>, first looking through the aircraft side window. Since 2016, specMACS has operated from a nadir-looking perspective in the rear of the fuselage of the <italic>HALO</italic> research aircraft. For that, the cameras were mounted into a pressurized housing with temperature stabilization and humidity control, and a 2 cm thick quartz glass window (Heraeus Herasil 102) in front of the cameras.</p>
      <?pagebreak page1421?><p id="d1e305">In 2019 for the EUREC<inline-formula><mml:math id="M2" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A field campaign <xref ref-type="bibr" rid="bib1.bibx60" id="paren.26"/>, the hyperspectral cameras were complemented by two 2D RGB polarization-resolving cameras, so-called polLL and polLR (polarization camera looking to the lower left (LL) and lower right (LR) relative to the flight direction, previously called polA and polB in <xref ref-type="bibr" rid="bib1.bibx52" id="altparen.27"/>). Both cameras are LUCID Vision Phoenix 5.0 MP Polarization Model cameras <xref ref-type="bibr" rid="bib1.bibx44" id="paren.28"/> with Sony's IMX250MYR sensor <xref ref-type="bibr" rid="bib1.bibx59" id="paren.29"/>. They measure in a synchronized manner with an acquisition frequency of 8 Hz and have an auto-exposure control system similar to the one described in <xref ref-type="bibr" rid="bib1.bibx22" id="text.30"/>. The sensor of a single camera has 2448 <inline-formula><mml:math id="M3" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 2048 px. It comprises a combination of a color filter array and a polarizer filter array and can be classified as a division-of-focal-plane polarimeter. The color filter array consists of a Bayer pattern of red, green, and blue color channels, and the polarizer filter array consists of four different on-chip directional polarizers with 0, 45, 90, and 135° polarization directions. A block of 4 <inline-formula><mml:math id="M4" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 4 px forms a super-pixel, whose pixel layout is visualized in Fig. <xref ref-type="fig" rid="Ch1.F1"/>. A super-pixel can be subdivided into blocks of 2 <inline-formula><mml:math id="M5" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 2 px for each color with the four different polarizers on each pixel. The on-chip directional polarizers are placed below the on-chip microlenses to reduce the distance between the polarizers and the photodiodes. With this specific sensor layout, simultaneous measurements of 0, 45, 90, and 135° polarization directions are possible and Stokes vectors can be calculated. The Stokes vector provides a full characterization of electromagnetic radiation and a quantitative description of polarization. It can be computed with (e.g., <xref ref-type="bibr" rid="bib1.bibx34" id="altparen.31"/>)
          <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M6" display="block"><mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mo>=</mml:mo><mml:mfenced open="(" close=")"><mml:mtable class="matrix" columnalign="center" framespacing="0em"><mml:mtr><mml:mtd><mml:mi>I</mml:mi></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mi>Q</mml:mi></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mi>U</mml:mi></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mi>V</mml:mi></mml:mtd></mml:mtr></mml:mtable></mml:mfenced><mml:mo>=</mml:mo><mml:mfenced close=")" open="("><mml:mtable class="matrix" columnalign="center" framespacing="0em"><mml:mtr><mml:mtd><mml:mrow><mml:mfenced open="(" close=")"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">45</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">135</mml:mn></mml:msub></mml:mrow></mml:mfenced><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">45</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">135</mml:mn></mml:msub></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:mi mathvariant="normal">right</mml:mi><mml:mtext>-</mml:mtext><mml:mi mathvariant="normal">handed</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:mi mathvariant="normal">left</mml:mi><mml:mtext>-</mml:mtext><mml:mi mathvariant="normal">handed</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:mfenced><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
        The polarization-resolving cameras can measure the <inline-formula><mml:math id="M7" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M8" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math id="M9" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> component of the Stokes vector. <inline-formula><mml:math id="M10" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> is the total intensity, and <inline-formula><mml:math id="M11" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M12" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> specify linear polarization. <inline-formula><mml:math id="M13" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula> describes circular polarization and is negligible in the atmosphere (e.g., <xref ref-type="bibr" rid="bib1.bibx34 bib1.bibx19" id="altparen.32"/>). The disadvantage of the filter array is that the measurements suffer from sparsity and instantaneous-field-of-view errors. These errors can however be reduced by applying interpolation strategies <xref ref-type="bibr" rid="bib1.bibx55 bib1.bibx62 bib1.bibx25" id="paren.33"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e544">Pixel layout of a super-pixel with the color and polarization filter array.</p></caption>
        <?xmltex \igopts{width=113.811024pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f01.png"/>

      </fig>

      <p id="d1e553">Each of the cameras is combined with a Cinegon <inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.8</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4.8</mml:mn></mml:mrow></mml:math></inline-formula> lens by Schneider-Kreuznach. The aperture is optimized for the operation on board the <italic>HALO</italic> research aircraft and set to a fixed value of 5.6. The two polarization-resolving cameras are installed with partially overlapping fields of view as shown in Fig. <xref ref-type="fig" rid="Ch1.F2"/>. This allows for a large overall field of view without the distortions of a fish-eye camera. A single camera has a field of view of 91° in the along-track direction and 78° in the across-track direction, and the maximum combined field of view is about 91° along-track and 117° across-track. The window in front of the cameras is tilted by 12° in the flight direction relative to the base plate of the instrument (see Fig. <xref ref-type="fig" rid="Ch1.F2"/>). A detailed description of the camera geometry is given in the following section. The specifications of the polarization-resolving cameras are summarized in Table <xref ref-type="table" rid="Ch1.T1"/>. Example measurements of the polarization-resolving cameras are shown in <xref ref-type="bibr" rid="bib1.bibx52" id="text.34"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e583"><bold>(a, b)</bold> Installation geometry of the two polarization-resolving cameras. The window in front of the cameras is shown in light blue, the dashed lines indicate the field of view of the cameras. <bold>(c)</bold> Observation geometry (panel from Fig. 3 in <xref ref-type="bibr" rid="bib1.bibx52" id="altparen.35"/>; citation in the panel refers to <xref ref-type="bibr" rid="bib1.bibx40" id="altparen.36"/>).</p></caption>
        <?xmltex \igopts{width=384.112205pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f02.png"/>

      </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e606">Specifications of the polarization-resolving cameras.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Lenses</oasis:entry>
         <oasis:entry colname="col2">Cinegon <inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.8</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">4.8</mml:mn></mml:mrow></mml:math></inline-formula> by</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Schneider-Kreuznach</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Focal length</oasis:entry>
         <oasis:entry colname="col2">4.8 mm</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Aperture</oasis:entry>
         <oasis:entry colname="col2">1.8–8 (set to 5.6)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Along-track field of view</oasis:entry>
         <oasis:entry colname="col2">91°</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Across-track field of view</oasis:entry>
         <oasis:entry colname="col2">78°</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Cameras</oasis:entry>
         <oasis:entry colname="col2">Phoenix 5.0 MP Polarization</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Model</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Sensor</oasis:entry>
         <oasis:entry colname="col2">Sony IMX250MYR CMOS</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Shutter type</oasis:entry>
         <oasis:entry colname="col2">Global</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Sensor resolution</oasis:entry>
         <oasis:entry colname="col2">5.0 MP</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Sensor pixels</oasis:entry>
         <oasis:entry colname="col2">2448 <inline-formula><mml:math id="M16" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 2048</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Pixel size</oasis:entry>
         <oasis:entry colname="col2">3.45<inline-formula><mml:math id="M17" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M18" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 3.45<inline-formula><mml:math id="M19" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Maximum frame rate</oasis:entry>
         <oasis:entry colname="col2">22 Hz</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Bit depth</oasis:entry>
         <oasis:entry colname="col2">12 bit (scaled to 16 bit)</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Dynamic range maximum</oasis:entry>
         <oasis:entry colname="col2">65 535 DN</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Combined field of view</oasis:entry>
         <oasis:entry colname="col2">91° <inline-formula><mml:math id="M20" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 117°</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><?xmltex \gdef\@currentlabel{1}?></table-wrap>

      <p id="d1e829">Applications of the data of the two polarization-resolving cameras so far have been the stereographic retrieval of 3D cloud geometry (<xref ref-type="bibr" rid="bib1.bibx40" id="altparen.37"/>, who do not use polarization information) and the retrieval of cloud droplet size distribution from polarized observations of the cloudbow <xref ref-type="bibr" rid="bib1.bibx52" id="paren.38"/>. While flying above a scene, certain (cloud) targets are sampled from different viewing angles (see Fig. <xref ref-type="fig" rid="Ch1.F2"/>c, figure from <xref ref-type="bibr" rid="bib1.bibx52" id="altparen.39"/>). This allows for the stereographic reconstruction of the target locations in three-dimensional space from which the 3D cloud geometry is derived. But it also provides multi-angle polarimetric information which can be used for retrievals like the derivation of cloud droplet size distribution by <xref ref-type="bibr" rid="bib1.bibx52" id="text.40"/>.</p>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Geometric calibration</title>
      <p id="d1e854">Both applications of the polarization-resolving cameras need an accurate geometric calibration for the correct localization of the targets. The geometric calibration consists of two steps. First, the camera model has to be defined and camera intrinsics and distortion coefficients have to be determined. Second, the exact location and orientation of the cameras in a fixed 3D world coordinate system have to be found in order to obtain georeferenced data.</p>
      <p id="d1e857">The camera model describes the transformation from world coordinates to pixel coordinates. It relates every pixel to its viewing direction, including distortions, e.g., due to lenses along the optical path. The parameters of the camera model include camera intrinsic parameters, distortion<?pagebreak page1422?> coefficients, and extrinsic parameters and can for example be computed with the chessboard calibration method <xref ref-type="bibr" rid="bib1.bibx66 bib1.bibx35" id="paren.41"/>. Multiple views of known targets like the corners of a chessboard can be used to fit the camera model and solve for the model parameters. Chessboard corners are the intersections of straight lines that are easily detectable and allow the model to be fitted up to subpixel accuracy.</p>
      <p id="d1e863">We performed the geometric camera calibration using the OpenCV library <xref ref-type="bibr" rid="bib1.bibx6" id="paren.42"/> and proceeded similarly to <xref ref-type="bibr" rid="bib1.bibx40" id="text.43"/>. But we applied OpenCV's rational camera model instead of the thin prism model. In total, we used 249 images of a chessboard with 9 <inline-formula><mml:math id="M21" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 6 corners with a 65 mm <inline-formula><mml:math id="M22" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 65 mm square size on an aluminum composite panel for the polLL camera and 212 images of the same chessboard for the polLR camera. Figure <xref ref-type="fig" rid="Ch1.F3"/> shows an example image of the chessboard measured by the polLR camera. The images were taken such that the chessboard corners were distributed over the entire field of view. All measurements were done with the cameras assembled inside the housing with the window in front of them as during aircraft operation. Due to the large field of view of the cameras and the consequential large incident angles on the window and its thickness of 2 cm, the window introduces a shift of the viewing directions. This shift results in an additional angle- and distance-dependent distortion of the detected chessboard corners. It cannot easily be included in the camera model, since it does not change the direction itself. In order to reduce the impact of the shift, we took the chessboard images with the chessboard at a few meters distance from the instrument – as far away as possible to minimize the impact of the window but close enough to detect all corners correctly. The mean root mean square reprojection error of the best-fit camera model of the polLL and polLR camera amounted to 0.18 and 0.20 px, respectively. The field of view of a single camera amounted to 91° <inline-formula><mml:math id="M23" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 78° (along-track <inline-formula><mml:math id="M24" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> across-track) and the maximum combined field of view to 91° <inline-formula><mml:math id="M25" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 117°, corresponding to a maximum combined swath of about 20 km <inline-formula><mml:math id="M26" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 33 km at a typical flight altitude of 10 km. In addition, the mean angular resolution is 0.04° in the along-track and across-track directions or about 10 m at a typical flight altitude of 10 km and a target at ground height. With the acquisition frequency of 8 Hz, the polarization-resolving cameras provide data with high angular resolution for angular sampling at a typical flight speed of 200 m s<inline-formula><mml:math id="M27" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, which corresponds to an angular resolution of up to 0.14° for a target at 10 km distance.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e932">Chessboard image taken by the polLR camera. The red circles indicate the detected chessboard corners.</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f03.png"/>

      </fig>

      <p id="d1e941">In the second step, the camera position and orientation for georeferencing had to be determined. Precise information about aircraft position (latitude, longitude, and altitude of the aircraft) and attitude (roll, pitch, and yaw angles) is available from the Basic HALO Measurement and Sensor System (BAHAMAS). BAHAMAS includes an inertial measurement unit, which is GPS-referenced with data from a global navigation satellite system <xref ref-type="bibr" rid="bib1.bibx27" id="paren.44"/>. The data are acquired with a rate of 100 Hz. After post-processing, the accuracy of the BAHAMAS data is 0.05 m for position data, 0.003° for roll and pitch angles, and 0.007 ° for true heading <xref ref-type="bibr" rid="bib1.bibx27" id="paren.45"/>. However, the BAHAMAS sensor is located at the front part of the aircraft, while the specMACS instrument is integrated in the boiler room in the rear part.<?pagebreak page1423?> Because of that, we expect the accuracy of the BAHAMAS attitude data for the specMACS instrument to be reduced because of bending and stretching of the aircraft fuselage during a flight. The orientation and position of the polarization-resolving cameras relative to the aircraft were determined with the method described by <xref ref-type="bibr" rid="bib1.bibx39" id="text.46"/>. An initial guess of the camera position and orientation is provided from the design documents. We then optimized the rotation angles by projecting specMACS measurements onto satellite images and matching features such as coastlines, lakes, or big roads. This was done once for every measurement campaign, since the instrument could be slightly misaligned after each integration into the aircraft. We optimized the orientation angles up to differences of 0.05°, which corresponds to a shift of 8.7 m at the ground for a flight altitude of 10 km.</p>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Radiometric characterization</title>
      <p id="d1e962">Besides the geometric calibration, we also characterized the cameras radiometrically. The output of each pixel is given as a digital number (DN). In order to convert this digital number into an absolute radiometric signal, the sensor needs to be calibrated.  This calibration includes the investigation of inter-pixel variations due to imperfections of the sensor material as well as other influences from the sensor electronics and optical components. In general, the sensor signal <inline-formula><mml:math id="M28" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> can be expressed as
          <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M29" display="block"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:mi mathvariant="script">N</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
        with the radiometric signal <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, the dark signal of the sensor <inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, and the sensor noise <inline-formula><mml:math id="M32" display="inline"><mml:mi mathvariant="script">N</mml:mi></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx22" id="paren.47"/>. The different components of the sensor signal will be characterized in the following sections. The calibration measurements were performed at the Calibration Home Base (CHB; <xref ref-type="bibr" rid="bib1.bibx15 bib1.bibx26" id="altparen.48"/>) of the Remote Sensing Technology Institute of the German Aerospace Center (DLR) in Oberpfaffenhofen in November 2021. All measurements were taken with the cameras mounted inside the housing as during aircraft operation. For radiometric measurements, we used the large integrating sphere (LIS) of the CHB, which is suited for the calibration of instruments with a large field of view. The LIS has a diameter of 1.65 m and an exit port of up to 55 cm, and its intensity can be changed using different combinations of its 18 different lamps. Only pixels illuminated by the lower hemisphere of the LIS were included in the analysis of the radiometric calibration data because the coating of the lower hemisphere was newer than the coating of the upper hemisphere, and due to the large field of view of the cameras, the edge between both hemispheres was visible in the calibration data. If not stated otherwise, all properties are given pixel-wise. Angle brackets denote a temporal average, and spatial averages are indicated by an overbar.</p>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Dark signal</title>
      <p id="d1e1043">The dark signal <inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is a pixel-dependent offset signal that the sensor measures when no light penetrates the camera. It can directly be measured from an averaged dark frame, <inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:mo>〈</mml:mo><mml:mi>S</mml:mi><mml:mo>〉</mml:mo><mml:mo>=</mml:mo><mml:mo>〈</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:mi mathvariant="script">N</mml:mi><mml:mo>〉</mml:mo></mml:mrow></mml:math></inline-formula>, since <inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula> if no light enters the camera and  <inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:mo>〈</mml:mo><mml:mi mathvariant="script">N</mml:mi><mml:mo>〉</mml:mo><mml:mo>→</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>. The dark signal can be split into two components and is generally dependent on exposure time <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and temperature <inline-formula><mml:math id="M38" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula>:
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M39" display="block"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>i</mml:mi><mml:mi mathvariant="normal">dc</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">read</mml:mi></mml:msub><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          The dark current <inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:msub><mml:mi>i</mml:mi><mml:mi mathvariant="normal">dc</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is caused by thermally generated electrons whose generation rate increases with increasing temperature.  The read-out offset <inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">read</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> originates from the A/D converters within the sensor. In contrast to the hyperspectral cameras, the polarization-resolving cameras do not have external shutters, which means that no dark signal can be characterized during measurement periods. Because of that, we estimate the dark signal for any measurement during field campaigns from the laboratory characterization.</p>
      <p id="d1e1208">For the analysis of the spatial structure of the dark signal, we averaged in total 5000 dark frames. The measurements were taken with an exposure time of 5 ms and at constant temperature. Results of this analysis are shown in Fig. <xref ref-type="fig" rid="Ch1.F4"/>. Mean and standard deviations of the dark signal across the sensor pixels of the polLL and polLR camera amounted to 17.08 <inline-formula><mml:math id="M42" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 1.19 and 17.04 <inline-formula><mml:math id="M43" display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 2.43 DN, respectively. These dark-signal levels correspond to 0.026 % of the digital-number range, which has a dynamic range maximum of 65 535 DN. For typical signal levels of 30 000 DN, the dark signal accounts for 0.057 % of the total signal. In addition, we investigated the temperature dependence of the dark signal (see Fig. <xref ref-type="fig" rid="Ch1.F5"/>). During two measurement series, the temperature varied from about 35 to 38 and 34 to 37 °C. The temperature was measured by the data logger of the instrument inside the housing and is used as a proxy for the temperature of the sensors. From the analysis, we found dark-signal drifts of 0.016 and 0.012 DN K<inline-formula><mml:math id="M44" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the polLL and polLR camera, respectively. Temperature variations during a research flight are usually greatest during takeoff and amount to up to 10 K until the aircraft reaches its cruising level and the temperature is stabilized at 25 °C for the remainder of the flight. Thus, the total dark-signal drift due to temperature variations during a research flight is 0.16 and 0.12 DN for polLL and polLR. Lastly, we analyzed the dependence of the dark signal on exposure time. We performed dark-signal measurements by averaging over 50 frames for exposure times between 0.05 and 100 ms at constant temperature. Figure <xref ref-type="fig" rid="Ch1.F6"/> shows slightly increasing dark-signal levels with exposure time. The total dark-signal drift due to varying exposure time is 0.23 and 0.22 DN for the polLL and polLR camera. Typical exposure times during aircraft operation are below 10 ms.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e1246">Spatial distribution of the dark signal averaged over 100 dark measurements with 50 frames each at an exposure time of 5 ms and constant temperature for the polLL camera <bold>(a)</bold> and polLR camera <bold>(b)</bold>.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f04.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5" specific-use="star"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e1264">Temperature dependence of the dark signal averaged over 50 frames for each temperature at an exposure time of 5 ms for the polLL camera <bold>(a)</bold> and polLR camera <bold>(b)</bold>. The dashed red curves indicate the temperature variations; the solid blue curves show the mean dark signal.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f05.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e1281">Exposure time dependence of the dark signal averaged over 50 frames at constant temperature for the polLL camera <bold>(a)</bold> and polLR camera <bold>(b)</bold>. The different lines show the different color and polarization channels.</p></caption>
          <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f06.png"/>

        </fig>

      <p id="d1e1296">In summary, the dark-signal level of both cameras is very small with only minor spatial variations and variations with exposure time and negligible temperature dependence. <?pagebreak page1424?> Thus, we use constant values of 17.08 and 17.04 DN for all channels of the polLL and polLR camera, respectively, for the dark-signal correction. The total standard deviation of the dark signal including spatial variations, temperature variations, and variations with exposure time is 1.22 and 2.44 DN for polLL and polLR. For typical signal levels of 30 000 DN, the total dark-signal drift corresponds to 0.004 % and 0.008 % of the signal.</p>
</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Linearity</title>
      <p id="d1e1307">Furthermore, we investigated the linearity of the sensors following <xref ref-type="bibr" rid="bib1.bibx24" id="text.49"/>. According to <xref ref-type="bibr" rid="bib1.bibx22" id="text.50"/>, the radiometric signal measured by a perfectly linear sensor with absolute radiometric response <inline-formula><mml:math id="M45" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> should depend linearly on input radiance <inline-formula><mml:math id="M46" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> and exposure time <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>:
            <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M48" display="block"><mml:mrow><mml:mover accent="true"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow><mml:mo mathvariant="normal" stretchy="true">̃</mml:mo></mml:mover><mml:mo>=</mml:mo><mml:mi>R</mml:mi><mml:mi>L</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          with the normalized signal or photocurrent <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mi>R</mml:mi><mml:mi>L</mml:mi></mml:mrow></mml:math></inline-formula>. A deviation between the observed signal <inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and the signal expected from a perfectly linear sensor <inline-formula><mml:math id="M51" display="inline"><mml:mover accent="true"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow><mml:mo mathvariant="normal" stretchy="true">̃</mml:mo></mml:mover></mml:math></inline-formula> is known as photoresponse non-linearity. To examine the linearity of the polarization-resolving cameras, we took measurements with different exposure times above the large integrating sphere assuming that the exposure time is linear. We measured 1000 frames with an acquisition rate of 8 Hz for each exposure time and averaged them. The output of the LIS has a standard deviation <inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula> % over a time period of 330 s and can thus be considered temporarily stable for the duration of the measurements <xref ref-type="bibr" rid="bib1.bibx3" id="paren.51"/>. We analyzed the linearity of the signal with exposure time for two different output intensities of the LIS in order to cover a large range of exposure times. The second intensity was about 12 % of the first intensity. Figure <xref ref-type="fig" rid="Ch1.F7"/> shows the average radiometric signal <inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:mo>〈</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>〉</mml:mo></mml:mrow></mml:math></inline-formula> as a function of exposure time for all different channels of the polLL and polLR camera for both intensities. The mean deviation of the observed signal from the perfectly linear signal of an ideal sensor was determined from a linear fit to the data. Its values are given for every channel in the figure and are generally larger for the measurements at smaller exposure times and higher LIS intensity (panels a and c). The mean deviations across all pixels of a certain color are 0.68 %, 0.70 %, and 0.96 % for the red, green, and blue color channel of the polLL camera and 0.45 %, 0.45 %, and 0.93 % for the polLR camera.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7" specific-use="star"><?xmltex \currentcnt{7}?><?xmltex \def\figurename{Figure}?><label>Figure 7</label><caption><p id="d1e1459">Linearity of the mean radiometric signal <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with exposure time for the different channels of the polLL camera <bold>(a, b)</bold> and the polLR camera <bold>(c, d)</bold> for two different intensities of the large integrating sphere. The dots indicate the observed signal; the lines are a linear fit assuming a perfectly linear sensor. The deviation of the observed signal of each channel from the linear model is given in the legends.</p></caption>
          <?xmltex \igopts{width=412.564961pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f07.png"/>

        </fig>

</sec>
<?pagebreak page1425?><sec id="Ch1.S4.SS3">
  <label>4.3</label><title>Noise</title>
      <p id="d1e1493">Noise in general consists of signal noise (photon shot noise) and dark noise. Dark noise is, analogously to the dark signal, composed of dark current noise due to statistical fluctuations of thermally generated electrons and read noise from the electronic read-out process. Photon shot noise originates from the temporally random distribution of photons arriving at the detector. The number of photons measured during a certain time interval can be described by a Poisson distribution. The standard deviation of a Poisson distribution with expectation value <inline-formula><mml:math id="M55" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> is proportional to <inline-formula><mml:math id="M56" display="inline"><mml:msqrt><mml:mi>N</mml:mi></mml:msqrt></mml:math></inline-formula>. Thus, the photon shot noise is directly proportional to the square root of the number <inline-formula><mml:math id="M57" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> of photoelectrons and the conversion gain <inline-formula><mml:math id="M58" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula>, and the total noise <inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="script">N</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> can be written as
            <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M60" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="script">N</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">shot</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:msqrt><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msup><mml:mi>k</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mi>N</mml:mi><mml:mo>+</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">r</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:msqrt><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">shot</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the photon shot noise and <inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the read noise <xref ref-type="bibr" rid="bib1.bibx37" id="paren.52"/>. For a linear sensor, the measured signal is directly proportional to the number of photons <inline-formula><mml:math id="M63" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula>. To analyze<?pagebreak page1426?> the noise characteristics of the polarization-resolving cameras, we computed the pixel-wise standard deviation across 1000 frames, which were taken above the LIS for different exposure times and two different output intensities of the LIS in order to cover a large enough signal range. Then, we calculated two-dimensional histograms of variance and noise as a function of averaged, dark-signal-corrected signal and fitted the Poisson model to them. This was done separately for every color and polarization channel. Figure <xref ref-type="fig" rid="Ch1.F8"/> displays the results for the r90 channel of the polLL and polLR camera. For a typical signal level of 30 000 DN, the noise is around 400 DN or 1.3 %. All other channels show similar results. The noise characteristics of both cameras are well captured by the Poisson model. Panels (a) and (c) show the expected linear relationship between the variance and the signal, while the noise scales with the square root of the signal in panels (b) and (d). Deviations from the Poisson model would be an indication of sensor non-linearities or non-Poisson noise.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><?xmltex \def\figurename{Figure}?><label>Figure 8</label><caption><p id="d1e1627">Noise characteristics of the r90 channel of the polLL camera <bold>(a, b)</bold> and the polLR camera <bold>(c, d)</bold>. Panels <bold>(a)</bold> and <bold>(c)</bold> show two-dimensional histograms of the variance as a function of average dark-signal-corrected signal and panels <bold>(b)</bold> and <bold>(d)</bold> the noise. The solid black lines denote the least-squares fit of the Poisson model given by the equation in the respective panel.</p></caption>
          <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f08.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS4">
  <label>4.4</label><title>Spectral response</title>
      <p id="d1e1664">The polarization-resolving cameras have a color filter array with red, green, and blue color channels. Measurements of the spectral response functions were performed using the Oriel MS257 monochromator of the CHB in the monochromator setup. The wavelength uncertainty in the monochromator is <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula> nm in the relevant wavelength range with a spectral bandwidth smaller than 0.54 nm and a relative radiometric uncertainty between 0.6 % and 0.9 % <xref ref-type="bibr" rid="bib1.bibx4 bib1.bibx5" id="paren.53"/>. We performed measurements for wavelengths between 370 and 750 nm in steps of 5 nm at an exposure time of 5 ms for both cameras. At every wavelength 50 frames were taken and averaged. Since the monochromator illuminates only a few pixels (about <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:mo>×</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula>), we performed measurements at seven different positions in the across-track direction and three different positions in the along-track direction in order to cover a certain number of pixels distributed across the sensor. We subtracted dark measurements from the data, corrected for the monochromator intensity, and normalized the spectral response functions to 1. Figure <xref ref-type="fig" rid="Ch1.F9"/> shows the resulting mean spectral response functions across all measured pixels for every channel of the polLL and polLR camera. The uncertainties include the standard deviation across the different pixels and the monochromator uncertainties. In general, there are only very small differences between the spectral response functions for the different polarization directions of each color. Center wavelengths and full width at half maximum (FWHM) were determined from a Gaussian fit for the red, green1, green2, and blue color channels. We obtained values of 621 nm (FWHM <inline-formula><mml:math id="M66" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 66 nm), 548 nm (118 nm), 545 nm (117 nm), and 468 nm (87 nm) for the center wavelengths of the polLL camera and 621 nm (67 nm), 548 nm (119 nm), 545 nm (117 nm), and 468 nm (87 nm) for polLR.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9" specific-use="star"><?xmltex \currentcnt{9}?><?xmltex \def\figurename{Figure}?><label>Figure 9</label><caption><p id="d1e1703">Relative spectral response function with uncertainty for the different color and polarization channels of the polLL camera <bold>(a)</bold> and polLR camera <bold>(b)</bold>.</p></caption>
          <?xmltex \igopts{width=398.338583pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f09.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS5">
  <label>4.5</label><title>Polarization calibration</title>
      <p id="d1e1726">In addition to general digital imaging errors, polarimeters have additional inaccuracies due to imperfections of the polarizers. Transmission, diattenuation, and orientation of the single on-chip directional polarizers can vary across the sensor due to misalignments and non-uniformities from manufacturing. These variations have to be compensated for by polarization calibration in order to correctly reconstruct the polarization signal from the measurements. There are a variety of different calibration techniques such as single-pixel calibration <xref ref-type="bibr" rid="bib1.bibx53" id="paren.54"/>, super-pixel calibration <xref ref-type="bibr" rid="bib1.bibx53 bib1.bibx43" id="paren.55"/>, and more complex calibration techniques based on super-pixel calibration (e.g., <xref ref-type="bibr" rid="bib1.bibx9 bib1.bibx65" id="altparen.56"/>). <xref ref-type="bibr" rid="bib1.bibx28 bib1.bibx29" id="text.57"/> reviewed different calibration methods for division-of-focal-plane polarimeters. They found that the super-pixel calibration method performs well and that more complex calibration methods do not improve the calibration results significantly. Hence, we also applied the super-pixel calibration method. In general, the transformation of an incident Stokes vector <inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:mi>I</mml:mi><mml:mo>,</mml:mo><mml:mi>Q</mml:mi><mml:mo>,</mml:mo><mml:mi>U</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mi>T</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula> into the measured intensities <inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">45</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">135</mml:mn></mml:msub><mml:msup><mml:mo>)</mml:mo><mml:mi>T</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula> can be described by
            <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M69" display="block"><mml:mrow><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="bold">A</mml:mi><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mo>+</mml:mo><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">45</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">135</mml:mn></mml:msub></mml:mrow></mml:mfenced><mml:mi>T</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula> is the dark signal, which was already characterized in Sect. <xref ref-type="sec" rid="Ch1.S4.SS1"/>, and <inline-formula><mml:math id="M71" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> is the so-called transfer matrix. The aim of the polarization calibration is to determine the transfer matrix <inline-formula><mml:math id="M72" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula>. We did this following two approaches. First, we introduced a theoretical polarization camera model for the transfer matrices for the entire sensor. Second, we used laboratory calibration measurements to compute transfer matrices and validate the model.</p>
      <p id="d1e1890">Since the super-pixel method combines pixels with all four different polarizers in a <inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>×</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> px neighborhood, it suffers from instantaneous-field-of-view errors. However, these errors can be reduced by interpolation <xref ref-type="bibr" rid="bib1.bibx55 bib1.bibx62 bib1.bibx25" id="paren.58"/>. Thus, we interpolated the measurements using a bilinear interpolation method in order to obtain measurements of all four polarization directions and all colors at every pixel before we applied the super-pixel calibration to every pixel. To avoid artifacts from extrapolation, we excluded the outermost super-pixel. The bilinear interpolation allows for very fast data analysis. It performs well in scenes without sharp edges, which we typically encounter in our application to the remote sensing of clouds. In the future, improved interpolation methods adapted to the combination of color and polarization filter arrays like the methods by <xref ref-type="bibr" rid="bib1.bibx49" id="text.59"/> or <xref ref-type="bibr" rid="bib1.bibx51" id="text.60"/> could be applied.</p><?xmltex \hack{\newpage}?>
<?pagebreak page1427?><sec id="Ch1.S4.SS5.SSS1">
  <label>4.5.1</label><title>Theoretical polarization camera model</title>
      <p id="d1e1922">First, we present the theoretical polarization camera model. The transfer matrix of an ideal sensor follows from Eq. (<xref ref-type="disp-formula" rid="Ch1.E1"/>):
              <disp-formula id="Ch1.E7" content-type="numbered"><label>7</label><mml:math id="M74" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="bold">A</mml:mi><mml:mi mathvariant="bold">ideal</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">2</mml:mn></mml:mfrac></mml:mstyle><mml:mfenced open="(" close=")"><mml:mtable class="matrix" columnalign="center center center" framespacing="0em"><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">1</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">1</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:mfenced><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
            Manufacturing imperfections lead to a deviation of the pixel transfer matrices from the ideal matrix and to variations between the pixels. <xref ref-type="bibr" rid="bib1.bibx43" id="text.61"/> calibrated the monochromatic version of the polarization-resolving cameras from the same manufacturer.  They focused on the central pixels of the sensor and found that the transfer matrices are consistent across this sensor region and a single matrix can be applied to all pixels. In addition, the deviation between the measured matrices and the ideal matrix was small for the central pixel region with small incident angles which they considered.</p>
      <?pagebreak page1428?><p id="d1e2000">The polarization-resolving cameras of specMACS are integrated into a housing with a window. This window can change the polarization state of the light passing through it and therefore must be considered in the polarization calibration. Its impact on the polarization can be described by the Mueller matrix of a linear diattenuator <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">M</mml:mi><mml:mi mathvariant="bold">window</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, which is given in <xref ref-type="bibr" rid="bib1.bibx2" id="text.62"/>. The matrix depends on the incident angles on the window as well as the refractive index of the window and is computed for every pixel and every color. The refractive index for every color is obtained by integrating the wavelength-dependent refractive index of the window with the spectral response functions of the cameras. Moreover, the incident angles can be calculated using the geometric calibration. Figure <xref ref-type="fig" rid="Ch1.F10"/> shows the 1,1 and 1,2 components of <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">M</mml:mi><mml:mi mathvariant="bold">window</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for the red channel of both cameras. The 1,1 component describes the total transmission through the window, which is slightly reduced towards the corners with increasing incident angles on the window. <inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mrow><mml:mi mathvariant="normal">window</mml:mi><mml:mo>,</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> specifies the impact of the window on the polarization.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10" specific-use="star"><?xmltex \currentcnt{10}?><?xmltex \def\figurename{Figure}?><label>Figure 10</label><caption><p id="d1e2053">The 1,1  and 1,2 components of the Mueller matrix describing the window for the red channel of the polLL and polLR camera.</p></caption>
            <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f10.png"/>

          </fig>

      <p id="d1e2063">In total, the transfer matrix is calculated with
              <disp-formula id="Ch1.E8" content-type="numbered"><label>8</label><mml:math id="M78" display="block"><mml:mrow><mml:mi mathvariant="bold">A</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="bold">A</mml:mi><mml:mi mathvariant="bold">ideal</mml:mi></mml:msub><mml:msub><mml:mi mathvariant="bold">M</mml:mi><mml:mi mathvariant="bold">window</mml:mi></mml:msub><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
            This transfer matrix does not include the lenses in front of the cameras. Since the lenses are in reality a combination of lenses whose exact design is not known to us, it was not possible to include a theoretical Mueller matrix for the lenses as well. According to <xref ref-type="bibr" rid="bib1.bibx43" id="text.63"/>, the choice of the camera lens has only little influence on the transfer matrices for the central pixel region of the camera where the incident angles of the rays are small. Thus, we assume that our theoretical model of the transfer matrices is a good approximation. However, lenses can introduce polarization aberrations, especially for larger incident angles towards the corner regions <xref ref-type="bibr" rid="bib1.bibx10" id="paren.64"/>. This effect is not included in the theoretical polarization calibration model. Because of that, we validated the theoretical model with a laboratory polarization calibration.</p>
</sec>
<sec id="Ch1.S4.SS5.SSS2">
  <label>4.5.2</label><title>Laboratory polarization calibration</title>
      <p id="d1e2104">For the laboratory polarization calibration, we performed calibration measurements with the polarizer setup of the CHB. A linear polarizer (Moxtek UBB01A) was mounted at a motorized rotation stage between specMACS and the large integrating sphere. This rotatable polarizer has a contrast ratio larger than 1000 for incident angles up to <inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula>°. With respect to the measurement precision of the polarization cameras, we thus considered the calibration light source as perfectly linearly polarized. We rotated the polarizer from  <inline-formula><mml:math id="M80" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>180 to 180° in steps of 15° and took 50 frames per angle, which we averaged. Due to the large field of view of the polarization-resolving cameras and the limited size of the polarizer, only a small part of the sensor was illuminated by the LIS with the polarizer. In order to cover at least large parts of the field of view, we tilted the entire instrument and took measurements for 32 different tilt angles in along-track and across-track direction and in nadir direction. Consequently, we achieved polarization measurements for 28.8 % of the pixels of the polLL camera and 29.6 % of the pixels of the polLR camera. Because of the size and the large weight of the specMACS instrument including the complete aircraft housing and environment control, tilting the instrument is very difficult, and it was not possible to obtain measurements for the entire field of view. The intensity of the sphere was monitored and stayed constant during the measurements.</p>
      <p id="d1e2124">We evaluated the polarization calibration measurements using the super-pixel calibration method. Since the output of the LIS after passing the polarizer was not known, we used normalized quantities similarly to <xref ref-type="bibr" rid="bib1.bibx43" id="text.65"/>:
              <disp-formula id="Ch1.E9" content-type="numbered"><label>9</label><mml:math id="M81" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mi mathvariant="bold">A</mml:mi><mml:msub><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            with the normalized intensities <inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">2</mml:mn><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">45</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">135</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mi mathvariant="bold-italic">I</mml:mi></mml:mrow></mml:math></inline-formula>, the normalized dark signal <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">2</mml:mn><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">45</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">90</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">135</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mi mathvariant="bold-italic">d</mml:mi></mml:mrow></mml:math></inline-formula>, and the normalized incoming Stokes vector
              <disp-formula id="Ch1.E10" content-type="numbered"><label>10</label><mml:math id="M84" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mfenced open="(" close=")"><mml:mtable class="matrix" columnalign="center" framespacing="0em"><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mrow><mml:mi>cos⁡</mml:mi><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">ϕ</mml:mi></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mrow><mml:mi>sin⁡</mml:mi><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">ϕ</mml:mi></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:mfenced><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
            Here, <inline-formula><mml:math id="M85" display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula> is the polarization angle of the rotatable linear polarizer. With that, <inline-formula><mml:math id="M86" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> could be fitted from the measured dark signal <inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and intensities <inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for every pixel using Eq. (<xref ref-type="disp-formula" rid="Ch1.E9"/>).</p>
      <p id="d1e2330">The Stokes vector and the transfer matrix are always defined relative to a reference plane. In connection with the polarization calibration, we distinguish three different reference systems. The laboratory reference system is defined by the plane containing the 0° axis of the linear polarizer between the large integrating sphere and the instrument and the normal of this polarizer. Moreover, the reference plane for the camera reference system for each camera is given by the <inline-formula><mml:math id="M89" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula>–<inline-formula><mml:math id="M90" display="inline"><mml:mi>z</mml:mi></mml:math></inline-formula> plane of the camera coordinate system with the <inline-formula><mml:math id="M91" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis parallel to the 0° direction of the polarizers on the sensor and the <inline-formula><mml:math id="M92" display="inline"><mml:mi>z</mml:mi></mml:math></inline-formula> axis normal to the focal plane array of the camera. Finally, the Stokes vectors can be rotated from the camera reference system into the scattering plane. The scattering plane is the plane containing the vector of the incoming solar radiation and the viewing direction of each pixel. Sketches visualizing the different reference systems can for example be found in <xref ref-type="bibr" rid="bib1.bibx21" id="text.66"/>. The transformation from the camera coordinate system to the scattering plane is known from the geometric calibration and varies between different observation geometries with different vectors of the incoming solar radiation. Thus, with the laboratory polarization calibration, we aim to compute the transfer matrices in the camera reference system.</p>
      <p id="d1e2364">For that, we defined the polarizer angles <inline-formula><mml:math id="M93" display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula> for the incoming Stokes vectors <inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> relative to the 0° axis of the linear polarizer between the large integrating sphere and the instrument and computed the transfer matrices first in the laboratory reference frame with the normalized super-pixel method described above. Therefore, we combined the laboratory measurements for different tilt angles into one laboratory reference system and solved Eq. (<xref ref-type="disp-formula" rid="Ch1.E9"/>) in a least-squares sense similarly to <xref ref-type="bibr" rid="bib1.bibx57" id="text.67"/> for the transfer matrices using the measured intensities and dark signal as well<?pagebreak page1429?> as the incoming Stokes vectors computed from the polarizer angles <inline-formula><mml:math id="M95" display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>. We only included illuminated pixels with viewing directions within <inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula>° perpendicular to the polarizer where the polarizer can be considered perfect. In addition, we excluded pixels with dirt or reflections on the window. With the resulting transfer matrices, Stokes vectors in the laboratory reference frame can be computed from measured intensities.</p>
      <p id="d1e2409">In a second step, we transformed the obtained transfer matrices from the laboratory reference system into the camera reference system. The direct determination of the rotation from the laboratory to the camera reference frame through the identification of the polarizer orientation visible in the measurements was not possible due to the angle-dependent shift introduced by the window, which is relevant at small distances. However, for single scattering, the <inline-formula><mml:math id="M97" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> component of the Stokes vector is zero in the scattering plane due to symmetries. We used this fact to find the rotation from the laboratory to the camera reference frame using measurements taken during the EUREC<inline-formula><mml:math id="M98" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A campaign <xref ref-type="bibr" rid="bib1.bibx60" id="paren.68"/> by minimizing <inline-formula><mml:math id="M99" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> along the scattering plane. Contributions from multiple scattering can in principle cause deviations of <inline-formula><mml:math id="M100" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> from zero. To minimize the influence of multiple scattering, we chose measurements from EUREC<inline-formula><mml:math id="M101" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A without clouds and with a minimum amount of aerosol. We applied the computed transfer matrices to measurement data from the EUREC<inline-formula><mml:math id="M102" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A campaign to compute Stokes vectors in the laboratory reference frame. Then, we rotated the obtained Stokes vectors with a single rotation matrix first from the laboratory into the camera reference system and next for every pixel from the camera reference system into the scattering plane. Since the transformation from the camera reference system to the scattering plane is known, we could optimize for the rotation from the laboratory to the camera reference system by minimizing the absolute value of <inline-formula><mml:math id="M103" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> along the scattering plane. With that, we obtained transfer matrices in the camera reference system for every measured pixel by applying this rotation matrix to the transfer matrices in the laboratory reference system obtained during the first step.</p>
      <?pagebreak page1430?><p id="d1e2471">The mean and standard deviation of <inline-formula><mml:math id="M104" display="inline"><mml:mi mathvariant="bold">A</mml:mi></mml:math></inline-formula> across all measured sensor pixels for the red channel of the polLL and polLR camera are
              <disp-formula id="Ch1.E11" content-type="numbered"><label>11</label><mml:math id="M105" display="block"><mml:mtable rowspacing="0.2ex" class="split" displaystyle="true" columnalign="right left"><mml:mtr><mml:mtd><mml:mrow><mml:msub><mml:mi mathvariant="bold">A</mml:mi><mml:mrow><mml:mi mathvariant="normal">polLL</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">red</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">2</mml:mn></mml:mfrac></mml:mstyle><mml:mfenced close=")" open="("><mml:mtable class="matrix" columnalign="center center center" framespacing="0em"><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.988</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.972</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.012</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1.010</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.021</mml:mn></mml:mrow></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.986</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.991</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.976</mml:mn></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.014</mml:mn></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1.006</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.025</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.984</mml:mn></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:mfenced></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:mo>±</mml:mo><mml:mfenced open="(" close=")"><mml:mtable class="matrix" columnalign="center center center" framespacing="0em"><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.012</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.008</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.058</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.005</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.059</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.007</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.012</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.005</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.057</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.006</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.060</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.007</mml:mn></mml:mtd></mml:mtr></mml:mtable></mml:mfenced></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
            and
              <disp-formula id="Ch1.E12" content-type="numbered"><label>12</label><mml:math id="M106" display="block"><mml:mtable class="split" rowspacing="0.2ex" displaystyle="true" columnalign="right left"><mml:mtr><mml:mtd><mml:mrow><mml:msub><mml:mi mathvariant="bold">A</mml:mi><mml:mrow><mml:mi mathvariant="normal">polLR</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">red</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mn mathvariant="normal">2</mml:mn></mml:mfrac></mml:mstyle><mml:mfenced open="(" close=")"><mml:mtable class="matrix" columnalign="center center center" framespacing="0em"><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.989</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.972</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.019</mml:mn></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1.007</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.019</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.993</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.991</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.978</mml:mn></mml:mrow></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.016</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">1.010</mml:mn></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.012</mml:mn></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.991</mml:mn></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:mfenced></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:mo>±</mml:mo><mml:mfenced open="(" close=")"><mml:mtable class="matrix" columnalign="center center center" framespacing="0em"><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.010</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.008</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.057</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.005</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.060</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.007</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.010</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.005</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.059</mml:mn></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mn mathvariant="normal">0.005</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.059</mml:mn></mml:mtd><mml:mtd><mml:mn mathvariant="normal">0.007</mml:mn></mml:mtd></mml:mtr></mml:mtable></mml:mfenced><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
            Other channels gave similar results. These transfer matrices include the impact of the entire optical system on the polarization including the window and the lenses. Since we used normalized intensities, they do not contain variations in absolute transmission across the sensor and absolute radiometric pixel response non-uniformity, which can be calibrated separately with a flat-field calibration. The deviation of the computed transfer matrices from the ideal matrix is small, as is the standard deviation of the transfer matrices across the sensor pixels. This indicates that the assumption of the ideal transfer matrix in the theoretical polarization model does not introduce large calibration errors.</p>
      <p id="d1e2746">A first quality check of the super-pixel polarization calibration is the reconstruction error, which is the relative deviation of the reconstructed Stokes vectors <inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mrow><mml:mi mathvariant="normal">n</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">r</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="bold">A</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="bold">1</mml:mn></mml:mrow></mml:msup><mml:mfenced close=")" open="("><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> using the measured intensities and the computed inverse transfer matrix from the incoming Stokes vectors <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. The mean reconstruction error across all pixels was negligible for the <inline-formula><mml:math id="M109" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> component of the Stokes vector for both cameras. For the <inline-formula><mml:math id="M110" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> component it amounted to <inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.37</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.60</mml:mn><mml:mo>)</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> for the red channel of the polLL camera, <inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.25</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.42</mml:mn><mml:mo>)</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> for  the red channel of the polLR camera, and values on the same order of magnitude for the other color channels of both cameras. In addition, we computed the relative calibration error introduced by <xref ref-type="bibr" rid="bib1.bibx43" id="text.69"/> for the red, green, and blue color channels of the polLL and polLR cameras. The error is defined as
              <disp-formula id="Ch1.E13" content-type="numbered"><label>13</label><mml:math id="M113" display="block"><mml:mrow><mml:mtext>Err</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">2</mml:mn><mml:msqrt><mml:mn mathvariant="normal">3</mml:mn></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>‖</mml:mo><mml:mi mathvariant="bold">A</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mi mathvariant="bold">A</mml:mi><mml:mi mathvariant="bold">ideal</mml:mi></mml:msub><mml:msub><mml:mo>‖</mml:mo><mml:mi mathvariant="normal">F</mml:mi></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mo>‖</mml:mo><mml:mspace linebreak="nobreak" width="0.25em"/><mml:msub><mml:mo>‖</mml:mo><mml:mi mathvariant="normal">F</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the Frobenius norm. It gives the upper limit of the error which is made when a polarization-resolving camera is used uncalibrated by applying the ideal transfer matrix and if the light is totally linearly polarized.  For partially polarized light, the error is smaller <xref ref-type="bibr" rid="bib1.bibx43" id="paren.70"/>. The relative calibration error of the mean transfer matrix for the red, green, and blue color channel amounts to 3.5 %, 3.5 %, and 4.6 % for the polLL camera and 3.1 %, 3.1 %, and 4.0 % for the polLR camera. These small errors indicate that the cameras are close to ideal cameras concerning polarization and that the error introduced by using the ideal transfer matrix instead of the transfer matrices obtained from the laboratory polarization calibration is small. The polarization calibration error when using the theoretical polarization camera model introduced in the previous section is expected to be even smaller, since the model additionally includes the window. Moreover, polarization measurements of clouds are usually only partially polarized, leading to a reduced relative polarization calibration error. Hence, the polarization calibration results from the theoretical model covering the entire field of view will be used in the following.</p><?xmltex \hack{\newpage}?>
</sec>
</sec>
<sec id="Ch1.S4.SS6">
  <label>4.6</label><title>Vignetting correction</title>
      <p id="d1e2922">Vignetting describes the intensity fall-off from pixels in the center towards pixels at the edges of the sensor. On the one hand, the brightness of off-axis image points is naturally reduced due to the geometry of the optical system. On the other hand, optical vignetting is caused by optical components like lenses. Off-axis incident light is blocked by physical components like the aperture and the edge of a lens, leading to an intensity decrease for rays with larger angles towards the sensor edges <xref ref-type="bibr" rid="bib1.bibx31 bib1.bibx2" id="paren.71"/>. Vignetting can be corrected for by applying a flat-field model <inline-formula><mml:math id="M115" display="inline"><mml:mi>F</mml:mi></mml:math></inline-formula>, which approximates the vignetting functions. The flat-field-corrected signal can be computed from the radiometric signal with
            <disp-formula id="Ch1.E14" content-type="numbered"><label>14</label><mml:math id="M116" display="block"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">F</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:mi>F</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          We used the parabolic vignetting model by <xref ref-type="bibr" rid="bib1.bibx41" id="text.72"/>, defined as
            <disp-formula id="Ch1.E15" content-type="numbered"><label>15</label><mml:math id="M117" display="block"><mml:mrow><mml:mi>F</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi>a</mml:mi><mml:mi>x</mml:mi></mml:msub><mml:msup><mml:mi>x</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msub><mml:mi>b</mml:mi><mml:mi>x</mml:mi></mml:msub><mml:mi>x</mml:mi><mml:mo>+</mml:mo><mml:msub><mml:mi>a</mml:mi><mml:mi>y</mml:mi></mml:msub><mml:msup><mml:mi>y</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msub><mml:mi>b</mml:mi><mml:mi>y</mml:mi></mml:msub><mml:mi>y</mml:mi><mml:mo>+</mml:mo><mml:mi>c</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          since it showed a better agreement with the observed vignetting compared to typical radial models for <inline-formula><mml:math id="M118" display="inline"><mml:mi>F</mml:mi></mml:math></inline-formula>. Here, <inline-formula><mml:math id="M119" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M120" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> are the pixel coordinates. All other parameters have to be determined from measurements of a uniformly illuminated scene. For that, we performed flat-field measurements using the LIS. We computed Stokes vectors from the dark-signal-corrected intensities with the transfer matrices from the polarization calibration and used the normalized <inline-formula><mml:math id="M121" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> component of the Stokes vector to fit the flat-field model for every color channel separately. Again, only the lower hemisphere of the LIS was included in the analysis, and pixels with reflections and dirt on the window were excluded. Figures <xref ref-type="fig" rid="Ch1.F11"/> and <xref ref-type="fig" rid="Ch1.F12"/> display the results of the red channel for the polLL and polLR camera, respectively. All other channels showed a similar behavior. The mean deviation between the model and the measurements for the red, green, and blue channel is <inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mn mathvariant="normal">0.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.2</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> %, <inline-formula><mml:math id="M123" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mn mathvariant="normal">0.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.3</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> %, and <inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mn mathvariant="normal">0.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.4</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> % for polLL and <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mn mathvariant="normal">0.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.3</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> %, <inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.3</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> %, and <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mn mathvariant="normal">0.0</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.3</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> % for polLR. Due to the large field of view of the instrument compared to the size of the LIS and the large size and weight of the instrument, it was not possible to perform flat-field measurements covering the entire field of view of the cameras with the calibration setup at the CHB. Because of that, the model was chosen for the vignetting correction in order to obtain a vignetting correction for the entire field of view despite some non-negligible residuals between the vignetting model and the flat-field measurements. The residuals include inhomogeneities of the LIS as well as deviations of the photoresponse non-uniformity of the cameras from the vignetting model. For future calibrations, flat-field measurements covering the entire field of view could be taken and directly be used for a more accurate flat-field correction which, for example, also includes pixel-to-pixel variations. In addition, possible inhomogeneities of the LIS could be accounted for by<?pagebreak page1431?> taking several measurements while rotating the tilted instrument above the LIS.</p>

      <?xmltex \floatpos{p}?><fig id="Ch1.F11" specific-use="star"><?xmltex \currentcnt{11}?><?xmltex \def\figurename{Figure}?><label>Figure 11</label><caption><p id="d1e3153">Flat-field model results for the red channel of the polLL camera. <bold>(a)</bold> Mean normalized, dark-signal-corrected total intensity. <bold>(b)</bold> Part of measurement in panel <bold>(a)</bold> used in the vignetting correction (removed LIS upper hemisphere, reflections, and dirt-affected areas). <bold>(c)</bold> Vignetting model fitted to the measurements. <bold>(d)</bold> Relative difference between vignetting model and measurements.</p></caption>
          <?xmltex \igopts{width=355.659449pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f11.png"/>

        </fig>

      <?xmltex \floatpos{p}?><fig id="Ch1.F12" specific-use="star"><?xmltex \currentcnt{12}?><?xmltex \def\figurename{Figure}?><label>Figure 12</label><caption><p id="d1e3179">Flat-field model results for the red channel of the polLR camera. <bold>(a)</bold> Mean normalized, dark-signal-corrected total intensity. <bold>(b)</bold> Part of measurement in panel <bold>(a)</bold> used in the vignetting correction (removed LIS upper hemisphere, reflections, and dirt-affected areas). <bold>(c)</bold> Vignetting model fitted to the measurements. <bold>(d)</bold> Relative difference between vignetting model and measurements.</p></caption>
          <?xmltex \igopts{width=355.659449pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f12.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS7">
  <label>4.7</label><title>Absolute radiometric response</title>
      <p id="d1e3211">Finally, the dark-signal-corrected, exposure-time-normalized, and flat-field-corrected Stokes vectors have to be converted into absolute radiances. In general, the absolute radiance <inline-formula><mml:math id="M128" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> in mW m<inline-formula><mml:math id="M129" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> nm<inline-formula><mml:math id="M130" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> sr<inline-formula><mml:math id="M131" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> is computed from the normalized signal <inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> in DN s<inline-formula><mml:math id="M133" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> with the absolute radiometric response <inline-formula><mml:math id="M134" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx22" id="paren.73"/>:
            <disp-formula id="Ch1.E16" content-type="numbered"><label>16</label><mml:math id="M135" display="block"><mml:mrow><mml:mi>L</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mi>R</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>⋅</mml:mo><mml:msub><mml:mi>s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          Here, the normalized signal is given by the exposure-time-normalized and vignetting-corrected Stokes vector
            <disp-formula id="Ch1.E17" content-type="numbered"><label>17</label><mml:math id="M136" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:mfenced close=")" open="("><mml:mrow><mml:mi>F</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          with <inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="bold">A</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="bold">1</mml:mn></mml:mrow></mml:msup><mml:mo>(</mml:mo><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. In order to determine the absolute radiometric response, we again used measurements of the LIS. We averaged 1000 frames and computed the exposure-time-normalized, vignetting-corrected Stokes vectors. The measured output spectrum of the LIS was integrated with the spectral response functions to obtain radiance values <inline-formula><mml:math id="M138" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> for every color channel. Then, we computed the absolute radiometric response <inline-formula><mml:math id="M139" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> using only the <inline-formula><mml:math id="M140" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> component of the normalized Stokes vectors <inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mrow><mml:mi mathvariant="normal">n</mml:mi><mml:mo>,</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>:
            <disp-formula id="Ch1.E18" content-type="numbered"><label>18</label><mml:math id="M142" display="block"><mml:mrow><mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>s</mml:mi><mml:mrow><mml:mi mathvariant="normal">n</mml:mi><mml:mo>,</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:msub></mml:mrow><mml:mi>L</mml:mi></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          Assuming that the photoresponse non-uniformity had already been accounted for by applying the vignetting correction, we computed a single absolute radiometric response for all pixels of a color channel by taking the mean across all pixels of the channel. Table <xref ref-type="table" rid="Ch1.T2"/> summarizes the resulting values of and uncertainties in the absolute radiometric response <inline-formula><mml:math id="M143" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> for the red, green, and blue color channels of the polLL and polLR camera. The relative uncertainties in the absolute radiometric response are 1.6 %, 2.2 %, and 3.0 % for the red, green, and blue channels of the polLL camera and 1.6 %, 1.9 %, and 3.3 % for the polLR camera. These uncertainties include the standard deviation of <inline-formula><mml:math id="M144" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> across all pixels, the uncertainty in the output of the LIS <xref ref-type="bibr" rid="bib1.bibx54" id="paren.74"/> as well as the spatial non-uniformity of the LIS, and the uncertainty in the spectral response functions. The photoresponse non-uniformity remaining after the vignetting correction is contained in the standard deviation of <inline-formula><mml:math id="M145" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> across all pixels. The systematic difference between the absolute radiometric response of the two cameras could come from the manual aperture setting.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e3475">Absolute radiometric response <inline-formula><mml:math id="M146" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> for the different color channels of the polLL and polLR camera in DN s<inline-formula><mml:math id="M147" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (mW m<inline-formula><mml:math id="M148" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> nm<inline-formula><mml:math id="M149" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> sr<inline-formula><mml:math id="M150" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)<inline-formula><mml:math id="M151" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> with uncertainties.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Red</oasis:entry>
         <oasis:entry colname="col3">Green</oasis:entry>
         <oasis:entry colname="col4">Blue</oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">polLL</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:mn mathvariant="normal">44</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mn mathvariant="normal">120</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">706</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:mn mathvariant="normal">60</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mn mathvariant="normal">823</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1367</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M154" display="inline"><mml:mrow><mml:mn mathvariant="normal">31</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">607</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">950</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">polLR</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M155" display="inline"><mml:mrow><mml:mn mathvariant="normal">46</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">549</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">766</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:mn mathvariant="normal">65</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">471</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1247</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:mn mathvariant="normal">34</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">559</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1137</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"/>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><?xmltex \gdef\@currentlabel{2}?></table-wrap>

      <p id="d1e3696">In summary, absolute calibrated Stokes vectors in the camera reference system can be calculated from the interpolated measured intensities via
            <disp-formula id="Ch1.E19" content-type="numbered"><label>19</label><mml:math id="M158" display="block"><mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="bold">A</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="bold">1</mml:mn></mml:mrow></mml:msup><mml:mo>(</mml:mo><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="bold-italic">d</mml:mi><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:mo>(</mml:mo><mml:mi>R</mml:mi><mml:mi>F</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          For further application of the measured polarization data to retrievals like the retrieval by <xref ref-type="bibr" rid="bib1.bibx52" id="text.75"/>, the Stokes vector of each pixel is rotated into its scattering plane with the Mueller rotation matrix <inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold">M</mml:mi><mml:mi mathvariant="bold">rot</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (e.g., <xref ref-type="bibr" rid="bib1.bibx50" id="altparen.76"/>):
            <disp-formula id="Ch1.E20" content-type="numbered"><label>20</label><mml:math id="M160" display="block"><mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="bold">M</mml:mi><mml:mi mathvariant="bold">rot</mml:mi></mml:msub><mml:msup><mml:mi mathvariant="bold">A</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="bold">1</mml:mn></mml:mrow></mml:msup><mml:mfenced close=")" open="("><mml:mrow><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="bold-italic">d</mml:mi></mml:mrow></mml:mfenced><mml:mo>/</mml:mo><mml:mfenced open="(" close=")"><mml:mrow><mml:mi>R</mml:mi><mml:mi>F</mml:mi><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S4.SS8">
  <label>4.8</label><title>Total radiometric uncertainty</title>
      <?pagebreak page1433?><p id="d1e3817">The estimation of the total radiometric uncertainty was achieved similarly to <xref ref-type="bibr" rid="bib1.bibx22" id="text.77"/> by applying Gaussian error propagation. The uncertainty in the radiometric signal <inline-formula><mml:math id="M161" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (here <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="bold-italic">d</mml:mi></mml:mrow></mml:math></inline-formula>) is given by the uncertainties in the dark signal  <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and the instantaneous noise of the signal <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="script">N</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>:
            <disp-formula id="Ch1.E21" content-type="numbered"><label>21</label><mml:math id="M165" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">d</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">exp</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="script">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:msqrt><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          The uncertainty in the dark signal consists of the dark-signal drift due to the temperature and exposure time dependence and the standard deviation of the dark signal across all sensor pixels as discussed in Sect. <xref ref-type="sec" rid="Ch1.S4.SS1"/>. The noise is a function of the signal and given in Sect. <xref ref-type="sec" rid="Ch1.S4.SS3"/>. Next, the uncertainty in the normalized and vignetting-corrected Stokes vectors can be computed. It consists of the uncertainty in the radiometric signal <inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, the uncertainty due to the sensor non-linearity discussed in Sect. <xref ref-type="sec" rid="Ch1.S4.SS2"/>, the uncertainty in the polarization calibration in Sect. <xref ref-type="sec" rid="Ch1.S4.SS5"/>, and the uncertainty in the vignetting correction in Sect. <xref ref-type="sec" rid="Ch1.S4.SS6"/>. The uncertainty in the polarization calibration is composed of the uncertainty in the transfer matrices <inline-formula><mml:math id="M167" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and a rotation uncertainty in the Stokes vectors <inline-formula><mml:math id="M168" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">rot</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> due to the uncertainty in the geometric calibration when rotating the Stokes vectors into the scattering plane.
            <disp-formula id="Ch1.E22" content-type="numbered"><label>22</label><mml:math id="M169" display="block"><mml:mrow><?xmltex \hack{\hbox\bgroup\fontsize{8.4}{8.4}\selectfont$\displaystyle}?><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">nonlin</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">A</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">rot</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">F</mml:mi></mml:msub></mml:mrow><mml:mi>F</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt><?xmltex \hack{$\egroup}?></mml:mrow></mml:math></disp-formula>
          We estimated the upper limit of the uncertainty in the transfer matrices with the deviation of the laboratory transfer matrices from the ideal transfer matrix using the error defined by <xref ref-type="bibr" rid="bib1.bibx43" id="text.78"/>. This is a very conservative estimate of the upper limit, since we included the impact of the window in the transfer matrices and our transfer matrices are thus more accurate than the ideal transfer matrix alone. Additionally, typical observations of clouds are only partially polarized, leading to a smaller relative polarization calibration error. The rotation error is zero for the <inline-formula><mml:math id="M170" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> component of the Stokes vector, since the total intensity is invariant under rotations, but it is non-zero for <inline-formula><mml:math id="M171" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula>. Finally, the total radiometric uncertainty is given by the combination of the uncertainty in the normalized Stokes vectors and the absolute radiometric response:
            <disp-formula id="Ch1.E23" content-type="numbered"><label>23</label><mml:math id="M172" display="block"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="bold-italic">S</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">R</mml:mi></mml:msub></mml:mrow><mml:mi>R</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          The uncertainty estimation was done for every color channel. Typical values of the total radiometric uncertainty for the <inline-formula><mml:math id="M173" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M174" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> components of the Stokes vector are given in Table <xref ref-type="table" rid="Ch1.T3"/>. The largest contribution to the total radiometric uncertainty is due to the polarization calibration. In general, total radiometric uncertainty is larger towards the corner regions and smaller in the center of the image. Due to the larger incident angles, the impact of the lenses as well as the window on polarization increases towards the corners, leading to an increased uncertainty in the polarization calibration compared to the center region.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e4200">Relative radiometric uncertainty <inline-formula><mml:math id="M175" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula> and absolute radiometric uncertainty <inline-formula><mml:math id="M176" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="bold-italic">S</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula> of the red, green, and blue color channels of the polLL and polLR cameras for a typical signal level of 30 000 DN and a typical value of the degree of linear polarization (DOLP) of 0.5 as in the cloudbow region.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="center"/>
     <oasis:thead>
       <oasis:row rowsep="1">

         <oasis:entry colname="col1"/>

         <oasis:entry colname="col2"/>

         <oasis:entry colname="col3"/>

         <oasis:entry colname="col4">Red</oasis:entry>

         <oasis:entry colname="col5">Green</oasis:entry>

         <oasis:entry colname="col6">Blue</oasis:entry>

       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>

         <oasis:entry rowsep="1" colname="col1" morerows="3">polLL</oasis:entry>

         <oasis:entry rowsep="1" colname="col2" morerows="1">Relative radiometric uncertainty <inline-formula><mml:math id="M177" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M178" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">3.8 %</oasis:entry>

         <oasis:entry colname="col5">3.8 %</oasis:entry>

         <oasis:entry colname="col6">4.9 %</oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry colname="col3"><inline-formula><mml:math id="M179" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">3.8 %</oasis:entry>

         <oasis:entry colname="col5">3.9 %</oasis:entry>

         <oasis:entry colname="col6">4.9 %</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry rowsep="1" colname="col2" morerows="1">Absolute radiometric uncertainty <inline-formula><mml:math id="M180" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="bold-italic">S</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M181" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">4.1 %</oasis:entry>

         <oasis:entry colname="col5">4.4 %</oasis:entry>

         <oasis:entry colname="col6">5.7 %</oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry colname="col3"><inline-formula><mml:math id="M182" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">4.1 %</oasis:entry>

         <oasis:entry colname="col5">4.5 %</oasis:entry>

         <oasis:entry colname="col6">5.8 %</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1" morerows="3">polLR</oasis:entry>

         <oasis:entry rowsep="1" colname="col2" morerows="1">Relative radiometric uncertainty <inline-formula><mml:math id="M183" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="bold-italic">s</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M184" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">3.4 %</oasis:entry>

         <oasis:entry colname="col5">3.4 %</oasis:entry>

         <oasis:entry colname="col6">4.4 %</oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry colname="col3"><inline-formula><mml:math id="M185" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">3.5 %</oasis:entry>

         <oasis:entry colname="col5">3.5 %</oasis:entry>

         <oasis:entry colname="col6">4.4 %</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col2" morerows="1">Absolute radiometric uncertainty <inline-formula><mml:math id="M186" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="bold-italic">S</mml:mi></mml:msub></mml:mrow><mml:mi mathvariant="bold-italic">S</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M187" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">3.8 %</oasis:entry>

         <oasis:entry colname="col5">3.9 %</oasis:entry>

         <oasis:entry colname="col6">5.5 %</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M188" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4">3.8 %</oasis:entry>

         <oasis:entry colname="col5">4.0 %</oasis:entry>

         <oasis:entry colname="col6">5.5 %</oasis:entry>

       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><?xmltex \gdef\@currentlabel{3}?></table-wrap>

      <p id="d1e4537">Another important quantity for polarization applications is the degree of linear polarization which can be computed from the Stokes vector with DOLP <inline-formula><mml:math id="M189" display="inline"><mml:mrow><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msup><mml:mi>Q</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mi>U</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt><mml:mo>/</mml:mo><mml:mi>I</mml:mi></mml:mrow></mml:math></inline-formula>. Its relative uncertainty was computed via Gaussian error  propagation from the uncertainties above. For Stokes vectors rotated into the scattering plane, the <inline-formula><mml:math id="M190" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> component of the Stokes vector is much smaller than <inline-formula><mml:math id="M191" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula>. Thus, neglecting the <inline-formula><mml:math id="M192" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> component, the relative uncertainty in the DOLP can be calculated with <inline-formula><mml:math id="M193" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">DOLP</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mtext>DOLP</mml:mtext><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>I</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mi>I</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>Q</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mi>Q</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt></mml:mrow></mml:math></inline-formula>.  Since the degree of linear polarization is invariant under rotations and independent of the absolute radiometric response, its uncertainty was computed from the relative radiometric uncertainties in <inline-formula><mml:math id="M194" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M195" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> in Eq. (<xref ref-type="disp-formula" rid="Ch1.E22"/>), neglecting the uncertainty in the absolute radiometric calibration and the rotation error. It amounts to 5.4 %, 5.4 %, and 6.9 % for the red, green, and blue channels of polLL and 4.8 %, 4.9 %, and 6.2 % for polLR for the same typical signal level and DOLP as in Table <xref ref-type="table" rid="Ch1.T3"/>. The uncertainties in the DOLP are large compared to other polarimetric instruments like RSP, AirHARP, or AirMSPI  <xref ref-type="bibr" rid="bib1.bibx38 bib1.bibx14" id="paren.79"/>. However, the uncertainties in the transfer matrices are a very conservative estimate, as discussed above. A substantial part of this error might actually be due to the difficult calibration procedure, and therefore the instrument error might be over-estimated, but we have no means to decide if this is the case. In addition, <xref ref-type="bibr" rid="bib1.bibx43" id="text.80"/>, who calibrated the monochromatic version of the same sensor, found maximum measurement errors of 3 % to 8 % for the DOLP even though they focused on the central pixel region where the errors are expected to be smaller. In general, the uncertainties could be reduced by a more accurate laboratory calibration with a setup that allows for taking polarization and flat-field calibration measurements for the entire field of view of the cameras.</p>
</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Validation</title>
      <p id="d1e4674">Finally, we applied the calibration to measurement data to compute georeferenced, absolute calibrated Stokes vectors rotated into the scattering plane. Moreover, the results are compared to simulations in order to validate the calibration. The sunglint originates from specular reflection of sunlight on the rough ocean surface. Observations of the sunglint are very well suited for a validation of the calibration with simulations, since it is a known target. Sunglint observations have for example been used for the in-flight calibration of POLDER <xref ref-type="bibr" rid="bib1.bibx61" id="paren.81"/>. Figure <xref ref-type="fig" rid="Ch1.F13"/>a–d show an example sunglint observation of the polLR camera measured on 22 January 2020 at 16:20 UTC west of Barbados above the tropical Atlantic Ocean during the EUREC<inline-formula><mml:math id="M196" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A field campaign. The sunglint is visible as a maximum in the total intensity in panel (a) and minimum in <inline-formula><mml:math id="M197" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> in panel (c) around the specular direction. The <inline-formula><mml:math id="M198" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> component in panel (d) is much smaller than <inline-formula><mml:math id="M199" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula>, as is expected for Stokes vectors rotated into the scattering plane.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F13" specific-use="star"><?xmltex \currentcnt{13}?><?xmltex \def\figurename{Figure}?><label>Figure 13</label><caption><p id="d1e4715"><bold>(a–d)</bold> Example sunglint observation of the green channel of the polLR camera on 22 January 2020 at 16:20 UTC. <bold>(e–h)</bold> Sunglint simulation corresponding to the observation in panels <bold>(a)</bold>–<bold>(d)</bold>. <bold>(i–l)</bold> Absolute difference in the sunglint observation and simulation in panels <bold>(a)</bold>–<bold>(d)</bold> and <bold>(e)</bold>–<bold>(h)</bold>. Mean and standard deviation of the absolute differences are given in the respective titles. <bold>(a, e, i)</bold> Total intensity. <bold>(b, f, j)</bold> Degree of linear polarization, <bold>(c, g, k)</bold> <inline-formula><mml:math id="M200" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> component of the Stokes vector. <bold>(d, h, l)</bold> <inline-formula><mml:math id="M201" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> component of the Stokes vector. The dashed lines indicate scattering angles.</p></caption>
        <?xmltex \igopts{width=455.244094pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/1419/2024/amt-17-1419-2024-f13.jpg"/>

      </fig>

      <p id="d1e4778">We performed polarized simulations of this specific observation with libRadtran <xref ref-type="bibr" rid="bib1.bibx47 bib1.bibx20" id="paren.82"/> and the Monte Carlo solver MYSTIC <xref ref-type="bibr" rid="bib1.bibx46 bib1.bibx18" id="paren.83"/>. For the ocean surface, we used the bidirectional reflectance distribution function (BRDF) by <xref ref-type="bibr" rid="bib1.bibx11 bib1.bibx12" id="text.84"/>, which we extended to polarization by considering the polarization-dependent Fresnel reflectivities. The sunglint shape and maximum intensity depend on wind speed and wind direction. The wind speed affects the width of the sunglint and can be fitted to measurements. For that, we performed several simulations for different wind speeds and determined the best-fit wind speed by a least-squares fit to the observation data along the scattering plane. Wind direction was taken from data of the <italic>METEOR</italic> ship, which was measuring close to the location of the <italic>HALO</italic> aircraft at the time of the observation. Since the measurement was taken above the tropical Atlantic Ocean, we assumed the tropical maritime aerosol mixture from the OPAC library <xref ref-type="bibr" rid="bib1.bibx36" id="paren.85"/> and derived aerosol mass concentrations for the mixture from data of the WALES lidar <xref ref-type="bibr" rid="bib1.bibx64" id="paren.86"/>, which was also measuring on board <italic>HALO</italic> using the method by <xref ref-type="bibr" rid="bib1.bibx32" id="text.87"/>. We chose an example observation with only small amounts of aerosol to reduce the uncertainty due to uncertainties in the retrieval and measurements of aerosol mass concentrations. In order to obtain simulations for the different color channels, we simulated a spectrum and integrated it with the spectral response functions derived during the laboratory calibration. To exclude situations with cirrus clouds above the <italic>HALO</italic> aircraft during the observation, the BACARDI cloud flag <xref ref-type="bibr" rid="bib1.bibx17" id="paren.88"/> was used. An undetected cirrus cloud between the<?pagebreak page1434?> sun and the aircraft would lead to a reduced sunglint intensity and discrepancies between observations and simulations.</p>
      <p id="d1e4816">Simulation results for the observation in Fig. <xref ref-type="fig" rid="Ch1.F13"/>a–d are shown in Fig. <xref ref-type="fig" rid="Ch1.F13"/>e–h.  In general, the simulation and observation agree well. Both simulated and observed Stokes vectors are rotated into the scattering plane for comparison. The <inline-formula><mml:math id="M202" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> component is much larger than the <inline-formula><mml:math id="M203" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> component, as is expected from symmetries. Differences between the observation and the simulation and their mean and standard deviation across all pixels can be seen in Fig. <xref ref-type="fig" rid="Ch1.F13"/>i–l. The mean absolute difference between the observation and simulation is smaller than 0.7 mW m<inline-formula><mml:math id="M204" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> nm<inline-formula><mml:math id="M205" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> sr<inline-formula><mml:math id="M206" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for all Stokes vector components. Mean relative differences in the <inline-formula><mml:math id="M207" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M208" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> components are <inline-formula><mml:math id="M209" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>1.1 % and 3.0 %, respectively. Thus, the observation and simulation agree within the expected uncertainties. The small-scale structures which are visible in the sunglint observations are due to the orientation of single waves on the ocean surface, which, of course, is not represented in the simulation. The <inline-formula><mml:math id="M210" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> component of the measured Stokes vectors is smaller than the simulations around the sunglint maximum, and the <inline-formula><mml:math id="M211" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> component in the same region is larger in the measurements compared to the simulations while the differences between simulated and observed <inline-formula><mml:math id="M212" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M213" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> components are small outside the sunglint; see Fig. <xref ref-type="fig" rid="Ch1.F13"/>i and k. This can be explained by the uncertainty in the wind speed and wind direction for the ocean BRDF in the simulations, since they affect the sunglint maximum intensity. An error in the absolute radiometric calibration would lead to differences across the entire field of view also outside the sunglint. The degree of linear polarization shows in general only small differences of <inline-formula><mml:math id="M214" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.03</mml:mn></mml:mrow></mml:math></inline-formula> with the largest values towards the corners. Since the degree of linear polarization is independent of the absolute calibration, the deviations between measurements and simulations are due to the uncertainty in the polarization calibration or a deviation of the assumed atmospheric constituents in the simulation from the observed ones which affect the polarization in the simulations. The differences could for example be explained by a small polarization impact of the lens in front of the camera or of the on-chip microlenses, which are not included in the theoretical polarization calibration. A more accurate laboratory calibration of the entire field of view including the corners would be necessary to quantify their impact. Due to the size and weight of the instrument, it was not possible to take calibration measurements for the corner regions with the setup at the CHB. In addition, deviations of the assumed aerosol properties from the measured ones could have an impact. The larger deviations of <inline-formula><mml:math id="M215" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> from zero in the observations compared to the simulations can also be explained by the uncertainty in the polarization calibration and the aerosol properties with the polarization calibration being the dominant factor. In addition, uncertainties in the geometric calibration lead to uncertainties in the rotation into the scattering plane, which could cause deviations from zero. However in summary, the observation and simulation agree within the expected uncertainties. For more accurate results, a laboratory polarization calibration for the entire field of view is necessary to include the polarization impact of all optical components. Moreover, the spatial field of the dark signal could be used instead of a single value for the dark-signal correction to further reduce the calibration uncertainties for retrievals of, e.g., aerosol or land properties with very small signal levels. In addition to the validation of the laboratory calibration, the sunglint observations and simulations could also be used for an in-flight calibration, which is very useful to continuously monitor the stability of the cameras between laboratory calibrations.</p>
</sec>
<sec id="Ch1.S6" sec-type="conclusions">
  <label>6</label><title>Summary</title>
      <p id="d1e4956">In this paper, we introduced the polarization upgrade of specMACS. In 2019, before the EUREC<inline-formula><mml:math id="M216" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A field campaign, the hyperspectral cameras of specMACS were complemented by two 2D RGB polarization-resolving cameras. The two polarization-resolving cameras have a large combined field of view of about 91° <inline-formula><mml:math id="M217" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 117° (along-track <inline-formula><mml:math id="M218" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> across-track) and high angular and spatial resolution. We performed a complete<?pagebreak page1435?> calibration and characterization of the polarization-resolving cameras and repeated the calibration of the VNIR spectrometer from <xref ref-type="bibr" rid="bib1.bibx22" id="text.89"/>. To this end, we conducted calibration measurements at the Calibration Home Base. Concerning the VNIR camera, we did not find significant differences between the calibration from 2016 and the new calibration.</p>
      <p id="d1e4985">With the calibration of the polarization-resolving cameras, we obtain georeferenced, absolute calibrated Stokes vectors rotated into the scattering plane from the raw data. The geometric calibration of the polarization-resolving cameras included a chessboard calibration for the determination of the camera model as well as a method for georeferencing. In addition, we completed a radiometric calibration of the two cameras. The dark signal was characterized to account for 0.057 % of the signal for typical signal levels with a small spatial variability across the sensor pixels, exposure time dependency, and temperature dependency of in total 0.004 % and 0.008 %. Moreover, the noise characteristics were captured well by the Poisson model and the non-linearity of the sensor was found to be below 1 %. Furthermore, we computed the spectral response for every channel from<?pagebreak page1436?> calibration measurements and performed a polarization calibration. For the polarization calibration, we used a theoretical camera model, which we validated with a laboratory calibration. Flat-field measurements were made and evaluated to obtain a vignetting correction. Finally, we carried out an absolute radiometric calibration of the cameras and calculated the total radiometric uncertainty, which ranges between 3.8 % and 5.8 % for the different channels of the two cameras for typical signal levels. The uncertainty is dominated by the uncertainty in the polarization calibration and increases from the center of the sensor towards the corners.</p>
      <p id="d1e4988">Afterwards, we applied the calibration to measurement data from the EUREC<inline-formula><mml:math id="M219" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A campaign and validated it with simulations. For that, we used observations of the sunglint, which is a well-characterized target and compared the observations to polarized radiative transfer simulations of the same measurement scene. This method could also be used for an in-flight calibration of the polarization-resolving cameras to continuously monitor the stability of the sensor in between laboratory calibrations. We found agreement between observations and simulations within the characterized accuracy and thus validated our calibration.</p>
</sec>

      
      </body>
    <back><notes notes-type="codedataavailability"><title>Code and data availability</title>

      <p id="d1e5004">The data and code used in this study are available upon request from the corresponding author.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e5010">TK, TZ, and BM realized the polarization upgrade of specMACS. TK developed the data acquisition software for the polarization-resolving cameras, the data file format, and the methods for geometric camera calibration. VP, AB, CR, and AW performed the calibration measurements. AB and CR processed the data of the utilities of the CHB. AW evaluated the calibration data and wrote the manuscript with input from all co-authors.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e5016">At least one of the (co-)authors is a member of the editorial board of <italic>Atmospheric Measurement Techniques</italic>. The peer-review process was guided by an independent editor, and the authors also have no other competing interests to declare.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e5025">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e5031">We would like to thank Markus Rapp (Institute for Atmospheric Physics, DLR Oberpfaffenhofen) for financing the calibration measurements at the Calibration Home Base. In addition, we thank Martin Wirth for providing the WALES lidar data for the sunglint simulation, Stefan Koppenhofer for his support during the laboratory calibration, and Claudia Emde for valuable explanations concerning polarization.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e5037">This research has been supported by the Deutsche Forschungsgemeinschaft (project SPP 1294, grant no. 442667104).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e5043">This paper was edited by Alyn Lambert and reviewed by Connor Lane and Brent McBride.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><?xmltex \def\ref@label{{Alexandrov et al.(2012)}}?><label>Alexandrov et al.(2012)</label><?label alexandrov2012?><mixed-citation>Alexandrov, M. D., Cairns, B., Emde, C., Ackerman, A. S., and van  Diedenhoven, B.: Accuracy assessments of cloud droplet size retrievals from  polarized reflectance measurements by the research scanning polarimeter,  Remote Sens. Environ., 125, 92–111, <ext-link xlink:href="https://doi.org/10.1016/j.rse.2012.07.012" ext-link-type="DOI">10.1016/j.rse.2012.07.012</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx2"><?xmltex \def\ref@label{{Bass et al.(2010)}}?><label>Bass et al.(2010)</label><?label bass2010a?><mixed-citation> Bass, M., DeCusatis, C. M., Enoch, J. M., Lakshminarayanan, V., Li, G.,  MacDonald, C., Mahajan, V. N., and Stryland, E. V.: Handbook of Optics Volume  I Geometrical and Physical Optics, Polarized Light, Components and  Instruments, 3rd edn., McGraw-Hill, Inc., ISBN 978-0-07-162925-6, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx3"><?xmltex \def\ref@label{{Baumgartner(2013)}}?><label>Baumgartner(2013)</label><?label baumgartner2013?><mixed-citation>Baumgartner, A.: Characterization of Integrating Sphere Homogeneity with an  Uncalibrated Imaging Spectrometer, in: Proc. WHISPERS 2013, Gainsville, Florida, USA, 25–28 June 2013, 1–4, <uri>https://elib.dlr.de/83300/</uri> (last access: 27 February 2024), 2013.</mixed-citation></ref>
      <ref id="bib1.bibx4"><?xmltex \def\ref@label{{Baumgartner(2019)}}?><label>Baumgartner(2019)</label><?label baumgartner2019?><mixed-citation>Baumgartner, A.: Grating monochromator wavelength calibration using an echelle grating wavelength meter, Opt. Express, 27, 13596–13610,  <ext-link xlink:href="https://doi.org/10.1364/OE.27.013596" ext-link-type="DOI">10.1364/OE.27.013596</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx5"><?xmltex \def\ref@label{{Baumgartner(2022)}}?><label>Baumgartner(2022)</label><?label baumgartner2021?><mixed-citation>Baumgartner, A.: Traceable Imaging Spectrometer Calibration and Transformation of Geometric and Spectral Pixel Properties, PhD thesis, Universität Osnabrück, <ext-link xlink:href="https://doi.org/10.48693/38" ext-link-type="DOI">10.48693/38</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx6"><?xmltex \def\ref@label{{Bradski(2000)}}?><label>Bradski(2000)</label><?label opencv_library?><mixed-citation> Bradski, G.: The OpenCV Library, Dr. Dobb's Journal of Software Tools, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx7"><?xmltex \def\ref@label{{Bréon and Goloub(1998)}}?><label>Bréon and Goloub(1998)</label><?label breon1998?><mixed-citation>Bréon, F.-M. and Goloub, P.: Cloud droplet effective radius from spaceborne  polarization measurements, Geophys. Res. Lett., 25, 1879–1882, <ext-link xlink:href="https://doi.org/10.1029/98GL01221" ext-link-type="DOI">10.1029/98GL01221</ext-link>, 1998.</mixed-citation></ref>
      <ref id="bib1.bibx8"><?xmltex \def\ref@label{{Cairns et al.(1999)}}?><label>Cairns et al.(1999)</label><?label cairns1999?><mixed-citation>Cairns, B., Russell, E. E., and Travis, L. D.: Research Scanning Polarimeter:  calibration and ground-based measurements, in: Polarization: Measurement,  Analysis, and Remote Sensing II, edited by: Goldstein, D. H. and Chenault,  D. B., International Society for Optics and Photonics, SPIE, 3754 186–196, <ext-link xlink:href="https://doi.org/10.1117/12.366329" ext-link-type="DOI">10.1117/12.366329</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bibx9"><?xmltex \def\ref@label{{Chen et al.(2015)Chen, Wang, and Liang}}?><label>Chen et al.(2015)Chen, Wang, and Liang</label><?label chen2015?><mixed-citation>Chen, Z., Wang, X., and Liang, R.: Calibration method of microgrid polarimeters with image interpolation, Appl. Optics, 54, 995–1001,  <ext-link xlink:href="https://doi.org/10.1364/AO.54.000995" ext-link-type="DOI">10.1364/AO.54.000995</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx10"><?xmltex \def\ref@label{{Chipman et al.(2018)}}?><label>Chipman et al.(2018)</label><?label chipman2018?><mixed-citation>Chipman, R., Lam, W. S. T., and Young, G.: Polarized Light and Optical Systems, 1st edn., CRC Press, <ext-link xlink:href="https://doi.org/10.1201/9781351129121" ext-link-type="DOI">10.1201/9781351129121</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx11"><?xmltex \def\ref@label{{Cox and Munk(1954a)}}?><label>Cox and Munk(1954a)</label><?label cox1954?><mixed-citation>Cox, C. and Munk, W.: Measurement of the Roughness of the Sea Surface from  Photographs of the Sun's Glitter, J. Opt. Soc. Am., 44, 838–850,  <ext-link xlink:href="https://doi.org/10.1364/JOSA.44.000838" ext-link-type="DOI">10.1364/JOSA.44.000838</ext-link>, 1954a.</mixed-citation></ref>
      <ref id="bib1.bibx12"><?xmltex \def\ref@label{{Cox and Munk(1954b)}}?><label>Cox and Munk(1954b)</label><?label cox1954b?><mixed-citation> Cox, C. and Munk, W.: Statistics of the sea surface derived from sun glitter,  J. Mar. Res., 13, 198–227, 1954b.</mixed-citation></ref>
      <?pagebreak page1437?><ref id="bib1.bibx13"><?xmltex \def\ref@label{{Deschamps et al.(1994)}}?><label>Deschamps et al.(1994)</label><?label deschamps1994?><mixed-citation>Deschamps, P.-Y., Breon, F.-M., Leroy, M., Podaire, A., Bricaud, A., Buriez,  J.-C., and Seze, G.: The POLDER mission: instrument characteristics and  scientific objectives, IEEE T. Geosci. Remote, 32, 598–615, <ext-link xlink:href="https://doi.org/10.1109/36.297978" ext-link-type="DOI">10.1109/36.297978</ext-link>, 1994.</mixed-citation></ref>
      <ref id="bib1.bibx14"><?xmltex \def\ref@label{{Diner et al.(2013)}}?><label>Diner et al.(2013)</label><?label diner2013?><mixed-citation>Diner, D. J., Xu, F., Garay, M. J., Martonchik, J. V., Rheingans, B. E., Geier, S., Davis, A., Hancock, B. R., Jovanovic, V. M., Bull, M. A., Capraro, K., Chipman, R. A., and McClain, S. C.: The Airborne Multiangle SpectroPolarimetric Imager (AirMSPI): a new tool for aerosol and cloud remote sensing, Atmos. Meas. Tech., 6, 2007–2025, <ext-link xlink:href="https://doi.org/10.5194/amt-6-2007-2013" ext-link-type="DOI">10.5194/amt-6-2007-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx15"><?xmltex \def\ref@label{{DLR Remote Sensing Technology Institute(2016)}}?><label>DLR Remote Sensing Technology Institute(2016)</label><?label chb?><mixed-citation>DLR Remote Sensing Technology Institute: The Calibration Home Base for  Imaging Spectrometers, Journal of large-scale research facilities, 2, A82,  <ext-link xlink:href="https://doi.org/10.17815/jlsrf-2-137" ext-link-type="DOI">10.17815/jlsrf-2-137</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx16"><?xmltex \def\ref@label{{Dubovik et al.(2019)}}?><label>Dubovik et al.(2019)</label><?label dubovik2019?><mixed-citation>Dubovik, O., Li, Z., Mishchenko, M. I., Tanré, D., Karol, Y., Bojkov, B.,  Cairns, B., Diner, D. J., Espinosa, W. R., Goloub, P., Gu, X., Hasekamp, O.,  Hong, J., Hou, W., Knobelspiesse, K. D., Landgraf, J., Li, L., Litvinov, P.,  Liu, Y., Lopatin, A., Marbach, T., Maring, H., Martins, V., Meijer, Y.,  Milinevsky, G., Mukai, S., Parol, F., Qiao, Y., Remer, L., Rietjens, J.,  Sano, I., Stammes, P., Stamnes, S., Sun, X., Tabary, P., Travis, L. D.,  Waquet, F., Xu, F., Yan, C., and Yin, D.: Polarimetric remote sensing of  atmospheric aerosols: Instruments, methodologies, results, and perspectives,  J. Quant. Spectrosc. Ra., 224, 474–511, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2018.11.024" ext-link-type="DOI">10.1016/j.jqsrt.2018.11.024</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx17"><?xmltex \def\ref@label{{Ehrlich et al.(2021)}}?><label>Ehrlich et al.(2021)</label><?label ehrlich2021?><mixed-citation>Ehrlich, A., Wolf, K., Luebke, A., Zoeger, M., and Giez, A.: Broadband solar  and terrestrial, upward and downward irradiance measured by BACARDI on HALO  during the EUREC4A Field Campaign, Aeris [data set], <ext-link xlink:href="https://doi.org/10.25326/160" ext-link-type="DOI">10.25326/160</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx18"><?xmltex \def\ref@label{{Emde et al.(2010)}}?><label>Emde et al.(2010)</label><?label emde2010?><mixed-citation>Emde, C., Buras, R., Mayer, B., and Blumthaler, M.: The impact of aerosols on polarized sky radiance: model development, validation, and applications, Atmos. Chem. Phys., 10, 383–396, <ext-link xlink:href="https://doi.org/10.5194/acp-10-383-2010" ext-link-type="DOI">10.5194/acp-10-383-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx19"><?xmltex \def\ref@label{{Emde et al.(2015)}}?><label>Emde et al.(2015)</label><?label emde2015?><mixed-citation>Emde, C., Barlakas, V., Cornet, C., Evans, F., Korkin, S., Ota, Y., Labonnote, L. C., Lyapustin, A., Macke, A., Mayer, B., and Wendisch, M.: IPRT polarized radiative transfer model intercomparison project – Phase A, J.  Quant. Spectrosc. Ra., 164, 8–36, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2015.05.007" ext-link-type="DOI">10.1016/j.jqsrt.2015.05.007</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx20"><?xmltex \def\ref@label{{Emde et al.(2016)}}?><label>Emde et al.(2016)</label><?label libradtran2016?><mixed-citation>Emde, C., Buras-Schnell, R., Kylling, A., Mayer, B., Gasteiger, J., Hamann, U., Kylling, J., Richter, B., Pause, C., Dowling, T., and Bugliaro, L.: The libRadtran software package for radiative transfer calculations (version 2.0.1), Geosci. Model Dev., 9, 1647–1672, <ext-link xlink:href="https://doi.org/10.5194/gmd-9-1647-2016" ext-link-type="DOI">10.5194/gmd-9-1647-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx21"><?xmltex \def\ref@label{{Eshelman et al.(2019)}}?><label>Eshelman et al.(2019)</label><?label eshelman2019?><mixed-citation>Eshelman, L. M., Tauc, M. J., and Shaw, J. A.: All-sky polarization imaging of cloud thermodynamic phase, Opt. Express, 27, 3528–3541,  <ext-link xlink:href="https://doi.org/10.1364/OE.27.003528" ext-link-type="DOI">10.1364/OE.27.003528</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx22"><?xmltex \def\ref@label{{Ewald et al.(2016)}}?><label>Ewald et al.(2016)</label><?label ewald2016?><mixed-citation>Ewald, F., Kölling, T., Baumgartner, A., Zinner, T., and Mayer, B.: Design and characterization of specMACS, a multipurpose hyperspectral cloud and sky imager, Atmos. Meas. Tech., 9, 2015–2042, <ext-link xlink:href="https://doi.org/10.5194/amt-9-2015-2016" ext-link-type="DOI">10.5194/amt-9-2015-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx23"><?xmltex \def\ref@label{{Ewald et al.(2019)}}?><label>Ewald et al.(2019)</label><?label ewald2019?><mixed-citation>Ewald, F., Zinner, T., Kölling, T., and Mayer, B.: Remote sensing of cloud droplet radius profiles using solar reflectance from cloud sides – Part 1: Retrieval development and characterization, Atmos. Meas. Tech., 12, 1183–1206, <ext-link xlink:href="https://doi.org/10.5194/amt-12-1183-2019" ext-link-type="DOI">10.5194/amt-12-1183-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx24"><?xmltex \def\ref@label{{Forster et al.(2020)}}?><label>Forster et al.(2020)</label><?label forster2020?><mixed-citation>Forster, L., Seefeldner, M., Baumgartner, A., Kölling, T., and Mayer, B.: Ice crystal characterization in cirrus clouds II: radiometric characterization of HaloCam for the quantitative analysis of halo displays, Atmos. Meas. Tech., 13, 3977–3991, <ext-link xlink:href="https://doi.org/10.5194/amt-13-3977-2020" ext-link-type="DOI">10.5194/amt-13-3977-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx25"><?xmltex \def\ref@label{{Gao and Gruev(2011)}}?><label>Gao and Gruev(2011)</label><?label gao2011?><mixed-citation>Gao, S. and Gruev, V.: Bilinear and bicubic interpolation methods for division of focal plane polarimeters, Opt. Express, 19, 26161–26173,  <ext-link xlink:href="https://doi.org/10.1364/OE.19.026161" ext-link-type="DOI">10.1364/OE.19.026161</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx26"><?xmltex \def\ref@label{{Gege et al.(2009)}}?><label>Gege et al.(2009)</label><?label gege2009?><mixed-citation>Gege, P., Fries, J., Haschberger, P., Schötz, P., Schwarzer, H., Strobl, P.,  Suhr, B., Ulbrich, G., and Jan Vreeling, W.: Calibration facility for  airborne imaging spectrometers, ISPRS J. Photogramm., 64, 387–397, <ext-link xlink:href="https://doi.org/10.1016/j.isprsjprs.2009.01.006" ext-link-type="DOI">10.1016/j.isprsjprs.2009.01.006</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx27"><?xmltex \def\ref@label{{Giez et al.(2021)}}?><label>Giez et al.(2021)</label><?label giez2021?><mixed-citation>Giez, A., Mallaun, C., Nenakhov, V., and Zöger, M.: Calibration of a Nose  Boom Mounted Airflow Sensor on an Atmospheric Research Aircraft by Inflight  Maneuvers, Tech. rep.,  Deutsches Zentrum für Luft- und Raumfahrt (DLR), <uri>https://elib.dlr.de/145969/</uri> (last access: 23 November 2022), 2021.</mixed-citation></ref>
      <ref id="bib1.bibx28"><?xmltex \def\ref@label{{Giménez et al.(2019)}}?><label>Giménez et al.(2019)</label><?label gimenez2019?><mixed-citation>Giménez, Y., Lapray, P.-J., Foulonneau, A., and Bigué, L.: Calibration  for polarization filter array cameras: recent advances, in: Fourteenth International Conference on Quality Control by Artificial Vision, SPIE, 1117216, <ext-link xlink:href="https://doi.org/10.1117/12.2521752" ext-link-type="DOI">10.1117/12.2521752</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx29"><?xmltex \def\ref@label{{Giménez et al.(2020)}}?><label>Giménez et al.(2020)</label><?label gimenez2020?><mixed-citation>Giménez, Y., Lapray, P.-J., Foulonneau, A., and Bigué, L.: Calibration algorithms for polarization filter array camera: survey and evaluation, J. Electron. Imaging, 29, 041011, <ext-link xlink:href="https://doi.org/10.1117/1.JEI.29.4.041011" ext-link-type="DOI">10.1117/1.JEI.29.4.041011</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx30"><?xmltex \def\ref@label{{Goloub et al.(2000)}}?><label>Goloub et al.(2000)</label><?label goloub2000?><mixed-citation>Goloub, P., Herman, M., Chepfer, H., Riedi, J., Brogniez, G., Couvert, P., and Séze, G.: Cloud thermodynamical phase classification from the POLDER  spaceborne instrument, J. Geophys. Res.-Atmos., 105, 14747–14759, <ext-link xlink:href="https://doi.org/10.1029/1999JD901183" ext-link-type="DOI">10.1029/1999JD901183</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx31"><?xmltex \def\ref@label{{Gross(2011)}}?><label>Gross(2011)</label><?label gross2011?><mixed-citation> Gross, H.: Handbook of Optical Systems: Fundamentals of Technical Optics, 1st edn., 2nd repr. edn., Wiley-VCH, Vol. 1, ISBN 978-3-527-40377-6, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx32"><?xmltex \def\ref@label{{Gutleben(2020)}}?><label>Gutleben(2020)</label><?label gutleben2020?><mixed-citation>Gutleben, M.: Long-range-transported Saharan air layers and their radiative  effects determined by airborne lidar measurements, PhD thesis,  Ludwig-Maximilians-Universität München,  <uri>http://nbn-resolving.de/urn:nbn:de:bvb:19-277095</uri> (last access: 12 April 2021), 2020.</mixed-citation></ref>
      <ref id="bib1.bibx33"><?xmltex \def\ref@label{{Hansen(1971)}}?><label>Hansen(1971)</label><?label hansen1971?><mixed-citation> Hansen, J. E.: Multiple scattering of polarized light in planetary atmospheres part II. Sunlight reflected by terrestrial water clouds, J. Atmos. Sci., 28, 1400–1426, 1971.</mixed-citation></ref>
      <ref id="bib1.bibx34"><?xmltex \def\ref@label{{Hansen and Travis(1974)}}?><label>Hansen and Travis(1974)</label><?label hansen1974?><mixed-citation>Hansen, J. E. and Travis, L. D.: Light scattering in planetary atmospheres,  Space Sci. Rev., 16, 527–610, <ext-link xlink:href="https://doi.org/10.1007/BF00168069" ext-link-type="DOI">10.1007/BF00168069</ext-link>, 1974.</mixed-citation></ref>
      <ref id="bib1.bibx35"><?xmltex \def\ref@label{{Heikkila and Silven(1997)}}?><label>Heikkila and Silven(1997)</label><?label heikkila1997?><mixed-citation>Heikkila, J. and Silven, O.: A four-step camera calibration procedure with  implicit image correction, in: Proceedings of IEEE Computer Society  Conference on Computer Vision and Pattern Recognition,  San Juan, PR, USA,  17–19 June 1997, IEEE, 1106–1112,  <ext-link xlink:href="https://doi.org/10.1109/CVPR.1997.609468" ext-link-type="DOI">10.1109/CVPR.1997.609468</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bibx36"><?xmltex \def\ref@label{{Hess et al.(1998)}}?><label>Hess et al.(1998)</label><?label hess1998?><mixed-citation> Hess, M., Koepke, P., and Schult, I.: Optical properties of aerosols and  clouds: the software package OPAC, B. Am. Meteorol. Soc., 79, 831–844, 1998.</mixed-citation></ref>
      <ref id="bib1.bibx37"><?xmltex \def\ref@label{{Janesick(2007)}}?><label>Janesick(2007)</label><?label janesick2007?><mixed-citation> Janesick, J. R.: Photon Transfer, Society of Photo-Optical Instrumentation  Engineers, ISBN 9780819467225, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx38"><?xmltex \def\ref@label{{Knobelspiesse et al.(2019)}}?><label>Knobelspiesse et al.(2019)</label><?label knobelspiesse2019?><mixed-citation>Knobelspiesse, K., Tan, Q., Bruegge, C., Cairns, B., Chowdhary, J., van  Diedenhoven, B., Diner, D., Ferrare, R., van Harten, G., Jovanovic, V.,  Ottaviani, M., Redemann, J., Seidel, F., and Sinclair, K.: Intercomparison of  airborne multi-angle polarimeter observations from the Polarimeter Definition  Experiment, Appl. Optics, 58, 650–669, <ext-link xlink:href="https://doi.org/10.1364/AO.58.000650" ext-link-type="DOI">10.1364/AO.58.000650</ext-link>, 2019.</mixed-citation></ref>
      <?pagebreak page1438?><ref id="bib1.bibx39"><?xmltex \def\ref@label{{K{\"{o}}lling(2020)}}?><label>Kölling(2020)</label><?label koelling2020?><mixed-citation>Kölling, T.: Cloud geometry for passive remote sensing, PhD thesis,  Ludwig-Maximilians-Universität München, <uri>http://nbn-resolving.de/urn:nbn:de:bvb:19-261616</uri> (last access: 13 April 2021), 2020.</mixed-citation></ref>
      <ref id="bib1.bibx40"><?xmltex \def\ref@label{{Kölling et al.(2019)}}?><label>Kölling et al.(2019)</label><?label koelling2019?><mixed-citation>Kölling, T., Zinner, T., and Mayer, B.: Aircraft-based stereographic reconstruction of 3-D cloud geometry, Atmos. Meas. Tech., 12, 1155–1166, <ext-link xlink:href="https://doi.org/10.5194/amt-12-1155-2019" ext-link-type="DOI">10.5194/amt-12-1155-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx41"><?xmltex \def\ref@label{{Kordecki et al.(2016)}}?><label>Kordecki et al.(2016)</label><?label kordecki2016?><mixed-citation>Kordecki, A., Palus, H., and Bal, A.: Practical vignetting correction method  for digital camera with measurement of surface luminance distribution, Signal Image Video P., 10, 1417–1424, <ext-link xlink:href="https://doi.org/10.1007/s11760-016-0941-2" ext-link-type="DOI">10.1007/s11760-016-0941-2</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx42"><?xmltex \def\ref@label{{Krautstrunk and Giez(2012)}}?><label>Krautstrunk and Giez(2012)</label><?label halo?><mixed-citation>Krautstrunk, M. and Giez, A.: The Transition From FALCON to HALO Era Airborne  Atmospheric Research, Springer Berlin Heidelberg, Berlin, Heidelberg, 609–624, ISBN 978-3-642-30183-4, <ext-link xlink:href="https://doi.org/10.1007/978-3-642-30183-4_37" ext-link-type="DOI">10.1007/978-3-642-30183-4_37</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx43"><?xmltex \def\ref@label{{Lane et al.(2022)}}?><label>Lane et al.(2022)</label><?label lane2022?><mixed-citation>Lane, C., Rode, D., and Rösgen, T.: Calibration of a polarization image  sensor and investigation of influencing factors, Appl. Optics, 61, C37–C45, <ext-link xlink:href="https://doi.org/10.1364/AO.437391" ext-link-type="DOI">10.1364/AO.437391</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx44"><?xmltex \def\ref@label{{{LUCID Vision Labs Inc.}(2023)}}?><label>LUCID Vision Labs Inc.(2023)</label><?label lucidvision?><mixed-citation>LUCID Vision Labs Inc.: Phoenix 5.0 MP Polarization Model (IMX250MZR/MYR), <uri>https://thinklucid.com/product/phoenix-5-0-mp-polarized-model/</uri> (last access: 17 July 2023), 2023.</mixed-citation></ref>
      <ref id="bib1.bibx45"><?xmltex \def\ref@label{{Martins et al.(2018)}}?><label>Martins et al.(2018)</label><?label martins2018?><mixed-citation>Martins, J. V., Fernandez-Borda, R., McBride, B., Remer, L., and Barbosa, H.  M. J.: The Harp Hype Ran Gular Imaging Polarimeter and the Need for Small  Satellite Payloads with High Science Payoff for Earth Science Remote Sensing,  in: IGARSS 2018 – 2018 IEEE International Geoscience and Remote Sensing  Symposium, Valencia, Spain, 22–27 July 2018, IEEE, 6304–6307, <ext-link xlink:href="https://doi.org/10.1109/IGARSS.2018.8518823" ext-link-type="DOI">10.1109/IGARSS.2018.8518823</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx46"><?xmltex \def\ref@label{{Mayer(2009)}}?><label>Mayer(2009)</label><?label mystic?><mixed-citation>Mayer, B.: Radiative transfer in the cloudy atmosphere, EPJ Web Conf., 1, 75–99, <ext-link xlink:href="https://doi.org/10.1140/epjconf/e2009-00912-1" ext-link-type="DOI">10.1140/epjconf/e2009-00912-1</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx47"><?xmltex \def\ref@label{{Mayer and Kylling(2005)}}?><label>Mayer and Kylling(2005)</label><?label libradtran2005?><mixed-citation>Mayer, B. and Kylling, A.: Technical note: The libRadtran software package for radiative transfer calculations - description and examples of use, Atmos. Chem. Phys., 5, 1855–1877, <ext-link xlink:href="https://doi.org/10.5194/acp-5-1855-2005" ext-link-type="DOI">10.5194/acp-5-1855-2005</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bibx48"><?xmltex \def\ref@label{{McBride et al.(2020)}}?><label>McBride et al.(2020)</label><?label mcbride2020?><mixed-citation>McBride, B. A., Martins, J. V., Barbosa, H. M. J., Birmingham, W., and Remer, L. A.: Spatial distribution of cloud droplet size properties from Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) measurements, Atmos. Meas. Tech., 13, 1777–1796, <ext-link xlink:href="https://doi.org/10.5194/amt-13-1777-2020" ext-link-type="DOI">10.5194/amt-13-1777-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx49"><?xmltex \def\ref@label{{Mihoubi et al.(2018)}}?><label>Mihoubi et al.(2018)</label><?label mihoubi2018?><mixed-citation>Mihoubi, S., Lapray, P.-J., and Bigué, L.: Survey of Demosaicking Methods for  Polarization Filter Array Images, Sensors, 18, <ext-link xlink:href="https://doi.org/10.3390/s18113688" ext-link-type="DOI">10.3390/s18113688</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx50"><?xmltex \def\ref@label{{Mishchenko et al.(2002)}}?><label>Mishchenko et al.(2002)</label><?label mishchenko2002?><mixed-citation> Mishchenko, M., Travis, L., and Lacis, A.: Scattering, Absorption, and Emission of Light by Small Particles, Cambridge University Press, Cambridge, UK, ISBN 0 521 78252 X, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx51"><?xmltex \def\ref@label{{Morimatsu et al.(2020)}}?><label>Morimatsu et al.(2020)</label><?label morimatsu2020?><mixed-citation>Morimatsu, M., Monno, Y., Tanaka, M., and Okutomi, M.: Monochrome And Color  Polarization Demosaicking Using Edge-Aware Residual Interpolation, in: 2020  IEEE International Conference on Image Processing (ICIP), Abu Dhabi, United Arab Emirates, 25–28 October 2020​​​​​​​, IEEE, 2571–2575,  <ext-link xlink:href="https://doi.org/10.1109/ICIP40778.2020.9191085" ext-link-type="DOI">10.1109/ICIP40778.2020.9191085</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx52"><?xmltex \def\ref@label{{Pörtge et al.(2023)}}?><label>Pörtge et al.(2023)</label><?label poertge2023?><mixed-citation>Pörtge, V., Kölling, T., Weber, A., Volkmer, L., Emde, C., Zinner, T., Forster, L., and Mayer, B.: High-spatial-resolution retrieval of cloud droplet size distribution from polarized observations of the cloudbow, Atmos. Meas. Tech., 16, 645–667, <ext-link xlink:href="https://doi.org/10.5194/amt-16-645-2023" ext-link-type="DOI">10.5194/amt-16-645-2023</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx53"><?xmltex \def\ref@label{{Powell and Gruev(2013)}}?><label>Powell and Gruev(2013)</label><?label powell2013?><mixed-citation> Powell, S. B. and Gruev, V.: Calibration methods for division-of-focal-plane  polarimeters, Opt. Express, 21, 21039–21055, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx54"><?xmltex \def\ref@label{{Rammeloo and Baumgartner(2023)}}?><label>Rammeloo and Baumgartner(2023)</label><?label rammeloo2023?><mixed-citation>Rammeloo, C. and Baumgartner, A.: Spectroradiometer Calibration for Radiance  Transfer Measurements, Sensors, 23, 2339, <ext-link xlink:href="https://doi.org/10.3390/s23042339" ext-link-type="DOI">10.3390/s23042339</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx55"><?xmltex \def\ref@label{{Ratliff et al.(2009)}}?><label>Ratliff et al.(2009)</label><?label ratliff2009?><mixed-citation>Ratliff, B. M., LaCasse, C. F., and Tyo, J. S.: Interpolation strategies for  reducing IFOV artifacts in microgrid polarimeter imagery, Opt. Express, 17,  9112–9125, <ext-link xlink:href="https://doi.org/10.1364/OE.17.009112" ext-link-type="DOI">10.1364/OE.17.009112</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx56"><?xmltex \def\ref@label{{Riedi et al.(2010)}}?><label>Riedi et al.(2010)</label><?label riedi2010?><mixed-citation>Riedi, J., Marchant, B., Platnick, S., Baum, B. A., Thieuleux, F., Oudard, C., Parol, F., Nicolas, J.-M., and Dubuisson, P.: Cloud thermodynamic phase inferred from merged POLDER and MODIS data, Atmos. Chem. Phys., 10, 11851–11865, <ext-link xlink:href="https://doi.org/10.5194/acp-10-11851-2010" ext-link-type="DOI">10.5194/acp-10-11851-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx57"><?xmltex \def\ref@label{{Rodriguez et al.(2022)}}?><label>Rodriguez et al.(2022)</label><?label rodriguez2022?><mixed-citation>Rodriguez, J., Lew-Yan-Voon, L., Martins, R., and Morel, O.: A Practical  Calibration Method for RGB Micro-Grid Polarimetric Cameras, IEEE Robotics and  Automation Letters, 7, 9921–9928, <ext-link xlink:href="https://doi.org/10.1109/LRA.2022.3192655" ext-link-type="DOI">10.1109/LRA.2022.3192655</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx58"><?xmltex \def\ref@label{{Smit et al.(2019)}}?><label>Smit et al.(2019)</label><?label smit2019?><mixed-citation>Smit, J. M., Rietjens, J. H. H., van Harten, G., Noia, A. D., Laauwen, W.,  Rheingans, B. E., Diner, D. J., Cairns, B., Wasilewski, A., Knobelspiesse,  K. D., Ferrare, R., and Hasekamp, O. P.: SPEX airborne spectropolarimeter  calibration and performance, Appl. Optics, 58, 5695–5719,  <ext-link xlink:href="https://doi.org/10.1364/AO.58.005695" ext-link-type="DOI">10.1364/AO.58.005695</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx59"><?xmltex \def\ref@label{{Sony Semiconductor Solutions Corporation(2023)}}?><label>Sony Semiconductor Solutions Corporation(2023)</label><?label sony?><mixed-citation>Sony Semiconductor Solutions Corporation: Polarization Image Sensor, <uri>https://www.sony-semicon.com/en/products/is/industry/polarization.html</uri> (last access: 17 July 2023), 2023.</mixed-citation></ref>
      <ref id="bib1.bibx60"><?xmltex \def\ref@label{{Stevens et al.(2021)}}?><label>Stevens et al.(2021)</label><?label eurec4a?><mixed-citation>Stevens, B., Bony, S., Farrell, D., Ament, F., Blyth, A., Fairall, C., Karstensen, J., Quinn, P. K., Speich, S., Acquistapace, C., Aemisegger, F., Albright, A. L., Bellenger, H., Bodenschatz, E., Caesar, K.-A., Chewitt-Lucas, R., de Boer, G., Delanoë, J., Denby, L., Ewald, F., Fildier, B., Forde, M., George, G., Gross, S., Hagen, M., Hausold, A., Heywood, K. J., Hirsch, L., Jacob, M., Jansen, F., Kinne, S., Klocke, D., Kölling, T., Konow, H., Lothon, M., Mohr, W., Naumann, A. K., Nuijens, L., Olivier, L., Pincus, R., Pöhlker, M., Reverdin, G., Roberts, G., Schnitt, S., Schulz, H., Siebesma, A. P., Stephan, C. C., Sullivan, P., Touzé-Peiffer, L., Vial, J., Vogel, R., Zuidema, P., Alexander, N., Alves, L., Arixi, S., Asmath, H., Bagheri, G., Baier, K., Bailey, A., Baranowski, D., Baron, A., Barrau, S., Barrett, P. A., Batier, F., Behrendt, A., Bendinger, A., Beucher, F., Bigorre, S., Blades, E., Blossey, P., Bock, O., Böing, S., Bosser, P., Bourras, D., Bouruet-Aubertot, P., Bower, K., Branellec, P., Branger, H., Brennek, M., Brewer, A., Brilouet , P.-E., Brügmann, B., Buehler, S. A., Burke, E., Burton, R., Calmer, R., Canonici, J.-C., Carton, X., Cato Jr., G., Charles, J. A., Chazette, P., Chen, Y., Chilinski, M. T., Choularton, T., Chuang, P., Clarke, S., Coe, H., Cornet, C., Coutris, P., Couvreux, F., Crewell, S., Cronin, T., Cui, Z., Cuypers, Y., Daley, A., Damerell, G. M., Dauhut, T., Deneke, H., Desbios, J.-P., Dörner, S., Donner, S., Douet, V., Drushka, K., Dütsch, M., Ehrlich, A., Emanuel, K., Emmanouilidis, A., Etienne, J.-C., Etienne-Leblanc, S., Faure, G., Feingold, G., Ferrero, L., Fix, A., Flamant, C., Flatau, P. J., Foltz, G. R., Forster, L., Furtuna, I., Gadian, A., Galewsky, J., Gallagher, M., Gallimore, P., Gaston, C., Gentemann, C., Geyskens, N., Giez, A., Gollop, J., Gouirand, I., Gourbeyre, C., de Graaf, D., de Groot, G. E., Grosz, R., Güttler, J., Gutleben, M., Hall, K., Harris, G., Helfer, K. C., Henze, D., Herbert, C., Holanda, B., Ibanez-Landeta, A., Intrieri, J., Iyer, S., Jul<?pagebreak page1439?>ien, F., Kalesse, H., Kazil, J., Kellman, A., Kidane, A. T., Kirchner, U., Klingebiel, M., Körner, M., Kremper, L. A., Kretzschmar, J., Krüger, O., Kumala, W., Kurz, A., L'Hégaret, P., Labaste, M., Lachlan-Cope, T., Laing, A., Landschützer, P., Lang, T., Lange, D., Lange, I., Laplace, C., Lavik, G., Laxenaire, R., Le Bihan, C., Leandro, M., Lefevre, N., Lena, M., Lenschow, D., Li, Q., Lloyd, G., Los, S., Losi, N., Lovell, O., Luneau, C., Makuch, P., Malinowski, S., Manta, G., Marinou, E., Marsden, N., Masson, S., Maury, N., Mayer, B., Mayers-Als, M., Mazel, C., McGeary, W., McWilliams, J. C., Mech, M., Mehlmann, M., Meroni, A. N., Mieslinger, T., Minikin, A., Minnett, P., Möller, G., Morfa Avalos, Y., Muller, C., Musat, I., Napoli, A., Neuberger, A., Noisel, C., Noone, D., Nordsiek, F., Nowak, J. L., Oswald, L., Parker, D. J., Peck, C., Person, R., Philippi, M., Plueddemann, A., Pöhlker, C., Pörtge, V., Pöschl, U., Pologne, L., Posyniak, M., Prange, M., Quiñones Meléndez, E., Radtke, J., Ramage, K., Reimann, J., Renault, L., Reus, K., Reyes, A., Ribbe, J., Ringel, M., Ritschel, M., Rocha, C. B., Rochetin, N., Röttenbacher, J., Rollo, C., Royer, H., Sadoulet, P., Saffin, L., Sandiford, S., Sandu, I., Schäfer, M., Schemann, V., Schirmacher, I., Schlenczek, O., Schmidt, J., Schröder, M., Schwarzenboeck, A., Sealy, A., Senff, C. J., Serikov, I., Shohan, S., Siddle, E., Smirnov, A., Späth, F., Spooner, B., Stolla, M. K., Szkółka, W., de Szoeke, S. P., Tarot, S., Tetoni, E., Thompson, E., Thomson, J., Tomassini, L., Totems, J., Ubele, A. A., Villiger, L., von Arx, J., Wagner, T., Walther, A., Webber, B., Wendisch, M., Whitehall, S., Wiltshire, A., Wing, A. A., Wirth, M., Wiskandt, J., Wolf, K., Worbes, L., Wright, E., Wulfmeyer, V., Young, S., Zhang, C., Zhang, D., Ziemen, F., Zinner, T., and Zöger, M.: EUREC<inline-formula><mml:math id="M220" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:math></inline-formula>A, Earth Syst. Sci. Data, 13, 4067–4119, <ext-link xlink:href="https://doi.org/10.5194/essd-13-4067-2021" ext-link-type="DOI">10.5194/essd-13-4067-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx61"><?xmltex \def\ref@label{{Toubbe et al.(1999)}}?><label>Toubbe et al.(1999)</label><?label toubbe1999?><mixed-citation>Toubbe, B., Bailleul, T., Deuze, J., Goloub, P., Hagolle, O., and Herman, M.:  In-flight calibration of the POLDER polarized channels using the Sun's  glitter, IEEE T. Geosci. Remote, 37, 513–524, <ext-link xlink:href="https://doi.org/10.1109/36.739104" ext-link-type="DOI">10.1109/36.739104</ext-link>, 1999. </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx62"><?xmltex \def\ref@label{{Tyo et al.(2009)}}?><label>Tyo et al.(2009)</label><?label tyo2009?><mixed-citation>Tyo, J. S., LaCasse, C. F., and Ratliff, B. M.: Total elimination of sampling  errors in polarization imagery obtained with integrated microgrid  polarimeters, Opt. Lett., 34, 3187–3189, <ext-link xlink:href="https://doi.org/10.1364/OL.34.003187" ext-link-type="DOI">10.1364/OL.34.003187</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx63"><?xmltex \def\ref@label{{van Diedenhoven et al.(2013)}}?><label>van Diedenhoven et al.(2013)</label><?label vandiedenhoven2013?><mixed-citation>van Diedenhoven, B., Cairns, B., Fridlind, A. M., Ackerman, A. S., and Garrett, T. J.: Remote sensing of ice crystal asymmetry parameter using multi-directional polarization measurements – Part 2: Application to the Research Scanning Polarimeter, Atmos. Chem. Phys., 13, 3185–3203, <ext-link xlink:href="https://doi.org/10.5194/acp-13-3185-2013" ext-link-type="DOI">10.5194/acp-13-3185-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx64"><?xmltex \def\ref@label{{Wirth et al.(2009)}}?><label>Wirth et al.(2009)</label><?label wirth2009?><mixed-citation>Wirth, M., Fix, A., Mahnke, P., Schwarzer, H., Schrandt, F., and Ehret, G.: The airborne multi-wavelength water vapor differential absorption LIDAR  WALES: system design and performance, Appl. Phys. B-Lasers O., 96, 201–213, <ext-link xlink:href="https://doi.org/10.1007/s00340-009-3365-7" ext-link-type="DOI">10.1007/s00340-009-3365-7</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx65"><?xmltex \def\ref@label{{Zhang et al.(2016)}}?><label>Zhang et al.(2016)</label><?label zhang2016?><mixed-citation>Zhang, J., Luo, H., Hui, B., and Chang, Z.: Non-uniformity correction for  division of focal plane polarimeters with a calibration method, Appl. Optics,  55, 7236–7240, <ext-link xlink:href="https://doi.org/10.1364/AO.55.007236" ext-link-type="DOI">10.1364/AO.55.007236</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx66"><?xmltex \def\ref@label{{Zhang(2000)}}?><label>Zhang(2000)</label><?label zhang2000?><mixed-citation>Zhang, Z.: A flexible new technique for camera calibration, IEEE T. Pattern Anal., 22, 1330–1334, <ext-link xlink:href="https://doi.org/10.1109/34.888718" ext-link-type="DOI">10.1109/34.888718</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx67"><?xmltex \def\ref@label{{Zinner et al.(2019)}}?><label>Zinner et al.(2019)</label><?label zinner2019?><mixed-citation>Zinner, T., Schwarz, U., Kölling, T., Ewald, F., Jäkel, E., Mayer, B., and Wendisch, M.: Cloud geometry from oxygen-A-band observations through an aircraft side window, Atmos. Meas. Tech., 12, 1167–1181, <ext-link xlink:href="https://doi.org/10.5194/amt-12-1167-2019" ext-link-type="DOI">10.5194/amt-12-1167-2019</ext-link>, 2019.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Polarization upgrade of specMACS: calibration and characterization of the 2D RGB  polarization-resolving cameras</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Alexandrov et al.(2012)</label><mixed-citation>
      
Alexandrov, M. D., Cairns, B., Emde, C., Ackerman, A. S., and van  Diedenhoven, B.: Accuracy assessments of cloud droplet size retrievals from  polarized reflectance measurements by the research scanning polarimeter,  Remote Sens. Environ., 125, 92–111, <a href="https://doi.org/10.1016/j.rse.2012.07.012" target="_blank">https://doi.org/10.1016/j.rse.2012.07.012</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Bass et al.(2010)</label><mixed-citation>
      
Bass, M., DeCusatis, C. M., Enoch, J. M., Lakshminarayanan, V., Li, G.,  MacDonald, C., Mahajan, V. N., and Stryland, E. V.: Handbook of Optics Volume  I Geometrical and Physical Optics, Polarized Light, Components and  Instruments, 3rd edn., McGraw-Hill, Inc., ISBN&thinsp;978-0-07-162925-6, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Baumgartner(2013)</label><mixed-citation>
      
Baumgartner, A.: Characterization of Integrating Sphere Homogeneity with an  Uncalibrated Imaging Spectrometer, in: Proc. WHISPERS 2013, Gainsville, Florida, USA, 25–28 June 2013, 1–4, <a href="https://elib.dlr.de/83300/" target="_blank"/> (last access: 27 February 2024), 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Baumgartner(2019)</label><mixed-citation>
      
Baumgartner, A.: Grating monochromator wavelength calibration using an echelle grating wavelength meter, Opt. Express, 27, 13596–13610,  <a href="https://doi.org/10.1364/OE.27.013596" target="_blank">https://doi.org/10.1364/OE.27.013596</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Baumgartner(2022)</label><mixed-citation>
      
Baumgartner, A.: Traceable Imaging Spectrometer Calibration and Transformation of Geometric and Spectral Pixel Properties, PhD thesis, Universität Osnabrück, <a href="https://doi.org/10.48693/38" target="_blank">https://doi.org/10.48693/38</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Bradski(2000)</label><mixed-citation>
      
Bradski, G.: The OpenCV Library, Dr. Dobb's Journal of Software Tools, 2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Bréon and Goloub(1998)</label><mixed-citation>
      
Bréon, F.-M. and Goloub, P.: Cloud droplet effective radius from spaceborne  polarization measurements, Geophys. Res. Lett., 25, 1879–1882, <a href="https://doi.org/10.1029/98GL01221" target="_blank">https://doi.org/10.1029/98GL01221</a>, 1998.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Cairns et al.(1999)</label><mixed-citation>
      
Cairns, B., Russell, E. E., and Travis, L. D.: Research Scanning Polarimeter:  calibration and ground-based measurements, in: Polarization: Measurement,  Analysis, and Remote Sensing II, edited by: Goldstein, D. H. and Chenault,  D. B., International Society for Optics and Photonics, SPIE, 3754 186–196, <a href="https://doi.org/10.1117/12.366329" target="_blank">https://doi.org/10.1117/12.366329</a>, 1999.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Chen et al.(2015)Chen, Wang, and Liang</label><mixed-citation>
      
Chen, Z., Wang, X., and Liang, R.: Calibration method of microgrid polarimeters with image interpolation, Appl. Optics, 54, 995–1001,  <a href="https://doi.org/10.1364/AO.54.000995" target="_blank">https://doi.org/10.1364/AO.54.000995</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Chipman et al.(2018)</label><mixed-citation>
      
Chipman, R., Lam, W. S. T., and Young, G.: Polarized Light and Optical Systems, 1st edn., CRC Press, <a href="https://doi.org/10.1201/9781351129121" target="_blank">https://doi.org/10.1201/9781351129121</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Cox and Munk(1954a)</label><mixed-citation>
      
Cox, C. and Munk, W.: Measurement of the Roughness of the Sea Surface from  Photographs of the Sun's Glitter, J. Opt. Soc. Am., 44, 838–850,  <a href="https://doi.org/10.1364/JOSA.44.000838" target="_blank">https://doi.org/10.1364/JOSA.44.000838</a>, 1954a.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Cox and Munk(1954b)</label><mixed-citation>
      
Cox, C. and Munk, W.: Statistics of the sea surface derived from sun glitter,  J. Mar. Res., 13, 198–227, 1954b.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Deschamps et al.(1994)</label><mixed-citation>
      
Deschamps, P.-Y., Breon, F.-M., Leroy, M., Podaire, A., Bricaud, A., Buriez,  J.-C., and Seze, G.: The POLDER mission: instrument characteristics and  scientific objectives, IEEE T. Geosci. Remote, 32, 598–615, <a href="https://doi.org/10.1109/36.297978" target="_blank">https://doi.org/10.1109/36.297978</a>, 1994.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Diner et al.(2013)</label><mixed-citation>
      
Diner, D. J., Xu, F., Garay, M. J., Martonchik, J. V., Rheingans, B. E., Geier, S., Davis, A., Hancock, B. R., Jovanovic, V. M., Bull, M. A., Capraro, K., Chipman, R. A., and McClain, S. C.: The Airborne Multiangle SpectroPolarimetric Imager (AirMSPI): a new tool for aerosol and cloud remote sensing, Atmos. Meas. Tech., 6, 2007–2025, <a href="https://doi.org/10.5194/amt-6-2007-2013" target="_blank">https://doi.org/10.5194/amt-6-2007-2013</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>DLR Remote Sensing Technology Institute(2016)</label><mixed-citation>
      
DLR Remote Sensing Technology Institute: The Calibration Home Base for  Imaging Spectrometers, Journal of large-scale research facilities, 2, A82,  <a href="https://doi.org/10.17815/jlsrf-2-137" target="_blank">https://doi.org/10.17815/jlsrf-2-137</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Dubovik et al.(2019)</label><mixed-citation>
      
Dubovik, O., Li, Z., Mishchenko, M. I., Tanré, D., Karol, Y., Bojkov, B.,  Cairns, B., Diner, D. J., Espinosa, W. R., Goloub, P., Gu, X., Hasekamp, O.,  Hong, J., Hou, W., Knobelspiesse, K. D., Landgraf, J., Li, L., Litvinov, P.,  Liu, Y., Lopatin, A., Marbach, T., Maring, H., Martins, V., Meijer, Y.,  Milinevsky, G., Mukai, S., Parol, F., Qiao, Y., Remer, L., Rietjens, J.,  Sano, I., Stammes, P., Stamnes, S., Sun, X., Tabary, P., Travis, L. D.,  Waquet, F., Xu, F., Yan, C., and Yin, D.: Polarimetric remote sensing of  atmospheric aerosols: Instruments, methodologies, results, and perspectives,  J. Quant. Spectrosc. Ra., 224, 474–511, <a href="https://doi.org/10.1016/j.jqsrt.2018.11.024" target="_blank">https://doi.org/10.1016/j.jqsrt.2018.11.024</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Ehrlich et al.(2021)</label><mixed-citation>
      
Ehrlich, A., Wolf, K., Luebke, A., Zoeger, M., and Giez, A.: Broadband solar  and terrestrial, upward and downward irradiance measured by BACARDI on HALO  during the EUREC4A Field Campaign, Aeris [data set], <a href="https://doi.org/10.25326/160" target="_blank">https://doi.org/10.25326/160</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Emde et al.(2010)</label><mixed-citation>
      
Emde, C., Buras, R., Mayer, B., and Blumthaler, M.: The impact of aerosols on polarized sky radiance: model development, validation, and applications, Atmos. Chem. Phys., 10, 383–396, <a href="https://doi.org/10.5194/acp-10-383-2010" target="_blank">https://doi.org/10.5194/acp-10-383-2010</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Emde et al.(2015)</label><mixed-citation>
      
Emde, C., Barlakas, V., Cornet, C., Evans, F., Korkin, S., Ota, Y., Labonnote, L. C., Lyapustin, A., Macke, A., Mayer, B., and Wendisch, M.: IPRT polarized radiative transfer model intercomparison project – Phase A, J.  Quant. Spectrosc. Ra., 164, 8–36, <a href="https://doi.org/10.1016/j.jqsrt.2015.05.007" target="_blank">https://doi.org/10.1016/j.jqsrt.2015.05.007</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Emde et al.(2016)</label><mixed-citation>
      
Emde, C., Buras-Schnell, R., Kylling, A., Mayer, B., Gasteiger, J., Hamann, U., Kylling, J., Richter, B., Pause, C., Dowling, T., and Bugliaro, L.: The libRadtran software package for radiative transfer calculations (version 2.0.1), Geosci. Model Dev., 9, 1647–1672, <a href="https://doi.org/10.5194/gmd-9-1647-2016" target="_blank">https://doi.org/10.5194/gmd-9-1647-2016</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Eshelman et al.(2019)</label><mixed-citation>
      
Eshelman, L. M., Tauc, M. J., and Shaw, J. A.: All-sky polarization imaging of cloud thermodynamic phase, Opt. Express, 27, 3528–3541,  <a href="https://doi.org/10.1364/OE.27.003528" target="_blank">https://doi.org/10.1364/OE.27.003528</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Ewald et al.(2016)</label><mixed-citation>
      
Ewald, F., Kölling, T., Baumgartner, A., Zinner, T., and Mayer, B.: Design and characterization of specMACS, a multipurpose hyperspectral cloud and sky imager, Atmos. Meas. Tech., 9, 2015–2042, <a href="https://doi.org/10.5194/amt-9-2015-2016" target="_blank">https://doi.org/10.5194/amt-9-2015-2016</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Ewald et al.(2019)</label><mixed-citation>
      
Ewald, F., Zinner, T., Kölling, T., and Mayer, B.: Remote sensing of cloud droplet radius profiles using solar reflectance from cloud sides – Part 1: Retrieval development and characterization, Atmos. Meas. Tech., 12, 1183–1206, <a href="https://doi.org/10.5194/amt-12-1183-2019" target="_blank">https://doi.org/10.5194/amt-12-1183-2019</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Forster et al.(2020)</label><mixed-citation>
      
Forster, L., Seefeldner, M., Baumgartner, A., Kölling, T., and Mayer, B.: Ice crystal characterization in cirrus clouds II: radiometric characterization of HaloCam for the quantitative analysis of halo displays, Atmos. Meas. Tech., 13, 3977–3991, <a href="https://doi.org/10.5194/amt-13-3977-2020" target="_blank">https://doi.org/10.5194/amt-13-3977-2020</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Gao and Gruev(2011)</label><mixed-citation>
      
Gao, S. and Gruev, V.: Bilinear and bicubic interpolation methods for division of focal plane polarimeters, Opt. Express, 19, 26161–26173,  <a href="https://doi.org/10.1364/OE.19.026161" target="_blank">https://doi.org/10.1364/OE.19.026161</a>, 2011.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Gege et al.(2009)</label><mixed-citation>
      
Gege, P., Fries, J., Haschberger, P., Schötz, P., Schwarzer, H., Strobl, P.,  Suhr, B., Ulbrich, G., and Jan Vreeling, W.: Calibration facility for  airborne imaging spectrometers, ISPRS J. Photogramm., 64, 387–397, <a href="https://doi.org/10.1016/j.isprsjprs.2009.01.006" target="_blank">https://doi.org/10.1016/j.isprsjprs.2009.01.006</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Giez et al.(2021)</label><mixed-citation>
      
Giez, A., Mallaun, C., Nenakhov, V., and Zöger, M.: Calibration of a Nose  Boom Mounted Airflow Sensor on an Atmospheric Research Aircraft by Inflight  Maneuvers, Tech. rep.,  Deutsches Zentrum für Luft- und Raumfahrt (DLR), <a href="https://elib.dlr.de/145969/" target="_blank"/> (last access: 23 November 2022), 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Giménez et al.(2019)</label><mixed-citation>
      
Giménez, Y., Lapray, P.-J., Foulonneau, A., and Bigué, L.: Calibration  for polarization filter array cameras: recent advances, in: Fourteenth International Conference on Quality Control by Artificial Vision, SPIE, 1117216, <a href="https://doi.org/10.1117/12.2521752" target="_blank">https://doi.org/10.1117/12.2521752</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Giménez et al.(2020)</label><mixed-citation>
      
Giménez, Y., Lapray, P.-J., Foulonneau, A., and Bigué, L.: Calibration algorithms for polarization filter array camera: survey and evaluation, J. Electron. Imaging, 29, 041011, <a href="https://doi.org/10.1117/1.JEI.29.4.041011" target="_blank">https://doi.org/10.1117/1.JEI.29.4.041011</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Goloub et al.(2000)</label><mixed-citation>
      
Goloub, P., Herman, M., Chepfer, H., Riedi, J., Brogniez, G., Couvert, P., and Séze, G.: Cloud thermodynamical phase classification from the POLDER  spaceborne instrument, J. Geophys. Res.-Atmos., 105, 14747–14759, <a href="https://doi.org/10.1029/1999JD901183" target="_blank">https://doi.org/10.1029/1999JD901183</a>, 2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Gross(2011)</label><mixed-citation>
      
Gross, H.: Handbook of Optical Systems: Fundamentals of Technical Optics, 1st edn., 2nd repr. edn., Wiley-VCH, Vol. 1, ISBN&thinsp;978-3-527-40377-6, 2011.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>Gutleben(2020)</label><mixed-citation>
      
Gutleben, M.: Long-range-transported Saharan air layers and their radiative  effects determined by airborne lidar measurements, PhD thesis,  Ludwig-Maximilians-Universität München,  <a href="http://nbn-resolving.de/urn:nbn:de:bvb:19-277095" target="_blank"/> (last access: 12 April 2021), 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Hansen(1971)</label><mixed-citation>
      
Hansen, J. E.: Multiple scattering of polarized light in planetary atmospheres part II. Sunlight reflected by terrestrial water clouds, J. Atmos. Sci., 28, 1400–1426, 1971.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Hansen and Travis(1974)</label><mixed-citation>
      
Hansen, J. E. and Travis, L. D.: Light scattering in planetary atmospheres,  Space Sci. Rev., 16, 527–610, <a href="https://doi.org/10.1007/BF00168069" target="_blank">https://doi.org/10.1007/BF00168069</a>, 1974.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Heikkila and Silven(1997)</label><mixed-citation>
      
Heikkila, J. and Silven, O.: A four-step camera calibration procedure with  implicit image correction, in: Proceedings of IEEE Computer Society  Conference on Computer Vision and Pattern Recognition,  San Juan, PR, USA,  17–19 June 1997, IEEE, 1106–1112,  <a href="https://doi.org/10.1109/CVPR.1997.609468" target="_blank">https://doi.org/10.1109/CVPR.1997.609468</a>, 1997.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>Hess et al.(1998)</label><mixed-citation>
      
Hess, M., Koepke, P., and Schult, I.: Optical properties of aerosols and  clouds: the software package OPAC, B. Am. Meteorol. Soc., 79, 831–844, 1998.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>Janesick(2007)</label><mixed-citation>
      
Janesick, J. R.: Photon Transfer, Society of Photo-Optical Instrumentation  Engineers, ISBN&thinsp;9780819467225, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>Knobelspiesse et al.(2019)</label><mixed-citation>
      
Knobelspiesse, K., Tan, Q., Bruegge, C., Cairns, B., Chowdhary, J., van  Diedenhoven, B., Diner, D., Ferrare, R., van Harten, G., Jovanovic, V.,  Ottaviani, M., Redemann, J., Seidel, F., and Sinclair, K.: Intercomparison of  airborne multi-angle polarimeter observations from the Polarimeter Definition  Experiment, Appl. Optics, 58, 650–669, <a href="https://doi.org/10.1364/AO.58.000650" target="_blank">https://doi.org/10.1364/AO.58.000650</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>Kölling(2020)</label><mixed-citation>
      
Kölling, T.: Cloud geometry for passive remote sensing, PhD thesis,  Ludwig-Maximilians-Universität München,
<a href="http://nbn-resolving.de/urn:nbn:de:bvb:19-261616" target="_blank"/> (last access: 13 April 2021), 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>Kölling et al.(2019)</label><mixed-citation>
      
Kölling, T., Zinner, T., and Mayer, B.: Aircraft-based stereographic reconstruction of 3-D cloud geometry, Atmos. Meas. Tech., 12, 1155–1166, <a href="https://doi.org/10.5194/amt-12-1155-2019" target="_blank">https://doi.org/10.5194/amt-12-1155-2019</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>Kordecki et al.(2016)</label><mixed-citation>
      
Kordecki, A., Palus, H., and Bal, A.: Practical vignetting correction method  for digital camera with measurement of surface luminance distribution, Signal Image Video P., 10, 1417–1424, <a href="https://doi.org/10.1007/s11760-016-0941-2" target="_blank">https://doi.org/10.1007/s11760-016-0941-2</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>Krautstrunk and Giez(2012)</label><mixed-citation>
      
Krautstrunk, M. and Giez, A.: The Transition From FALCON to HALO Era Airborne  Atmospheric Research, Springer Berlin Heidelberg, Berlin, Heidelberg, 609–624, ISBN&thinsp;978-3-642-30183-4, <a href="https://doi.org/10.1007/978-3-642-30183-4_37" target="_blank">https://doi.org/10.1007/978-3-642-30183-4_37</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>Lane et al.(2022)</label><mixed-citation>
      
Lane, C., Rode, D., and Rösgen, T.: Calibration of a polarization image  sensor and investigation of influencing factors, Appl. Optics, 61, C37–C45,
<a href="https://doi.org/10.1364/AO.437391" target="_blank">https://doi.org/10.1364/AO.437391</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>LUCID Vision Labs Inc.(2023)</label><mixed-citation>
      
LUCID Vision Labs Inc.: Phoenix 5.0 MP Polarization Model (IMX250MZR/MYR),
<a href="https://thinklucid.com/product/phoenix-5-0-mp-polarized-model/" target="_blank"/> (last access: 17 July 2023), 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>Martins et al.(2018)</label><mixed-citation>
      
Martins, J. V., Fernandez-Borda, R., McBride, B., Remer, L., and Barbosa, H.  M. J.: The Harp Hype Ran Gular Imaging Polarimeter and the Need for Small  Satellite Payloads with High Science Payoff for Earth Science Remote Sensing,  in: IGARSS 2018 – 2018 IEEE International Geoscience and Remote Sensing  Symposium, Valencia, Spain, 22–27 July 2018, IEEE, 6304–6307, <a href="https://doi.org/10.1109/IGARSS.2018.8518823" target="_blank">https://doi.org/10.1109/IGARSS.2018.8518823</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>Mayer(2009)</label><mixed-citation>
      
Mayer, B.: Radiative transfer in the cloudy atmosphere, EPJ Web Conf., 1, 75–99, <a href="https://doi.org/10.1140/epjconf/e2009-00912-1" target="_blank">https://doi.org/10.1140/epjconf/e2009-00912-1</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>Mayer and Kylling(2005)</label><mixed-citation>
      
Mayer, B. and Kylling, A.: Technical note: The libRadtran software package for radiative transfer calculations - description and examples of use, Atmos. Chem. Phys., 5, 1855–1877, <a href="https://doi.org/10.5194/acp-5-1855-2005" target="_blank">https://doi.org/10.5194/acp-5-1855-2005</a>, 2005.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>McBride et al.(2020)</label><mixed-citation>
      
McBride, B. A., Martins, J. V., Barbosa, H. M. J., Birmingham, W., and Remer, L. A.: Spatial distribution of cloud droplet size properties from Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) measurements, Atmos. Meas. Tech., 13, 1777–1796, <a href="https://doi.org/10.5194/amt-13-1777-2020" target="_blank">https://doi.org/10.5194/amt-13-1777-2020</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>Mihoubi et al.(2018)</label><mixed-citation>
      
Mihoubi, S., Lapray, P.-J., and Bigué, L.: Survey of Demosaicking Methods for  Polarization Filter Array Images, Sensors, 18, <a href="https://doi.org/10.3390/s18113688" target="_blank">https://doi.org/10.3390/s18113688</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>Mishchenko et al.(2002)</label><mixed-citation>
      
Mishchenko, M., Travis, L., and Lacis, A.: Scattering, Absorption, and Emission of Light by Small Particles, Cambridge University Press, Cambridge, UK, ISBN&thinsp;0&thinsp;521&thinsp;78252&thinsp;X, 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>Morimatsu et al.(2020)</label><mixed-citation>
      
Morimatsu, M., Monno, Y., Tanaka, M., and Okutomi, M.: Monochrome And Color  Polarization Demosaicking Using Edge-Aware Residual Interpolation, in: 2020  IEEE International Conference on Image Processing (ICIP), Abu Dhabi, United Arab Emirates, 25–28 October 2020​​​​​​​, IEEE, 2571–2575,  <a href="https://doi.org/10.1109/ICIP40778.2020.9191085" target="_blank">https://doi.org/10.1109/ICIP40778.2020.9191085</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>Pörtge et al.(2023)</label><mixed-citation>
      
Pörtge, V., Kölling, T., Weber, A., Volkmer, L., Emde, C., Zinner, T., Forster, L., and Mayer, B.: High-spatial-resolution retrieval of cloud droplet size distribution from polarized observations of the cloudbow, Atmos. Meas. Tech., 16, 645–667, <a href="https://doi.org/10.5194/amt-16-645-2023" target="_blank">https://doi.org/10.5194/amt-16-645-2023</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>Powell and Gruev(2013)</label><mixed-citation>
      
Powell, S. B. and Gruev, V.: Calibration methods for division-of-focal-plane  polarimeters, Opt. Express, 21, 21039–21055, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>Rammeloo and Baumgartner(2023)</label><mixed-citation>
      
Rammeloo, C. and Baumgartner, A.: Spectroradiometer Calibration for Radiance  Transfer Measurements, Sensors, 23, 2339, <a href="https://doi.org/10.3390/s23042339" target="_blank">https://doi.org/10.3390/s23042339</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>Ratliff et al.(2009)</label><mixed-citation>
      
Ratliff, B. M., LaCasse, C. F., and Tyo, J. S.: Interpolation strategies for  reducing IFOV artifacts in microgrid polarimeter imagery, Opt. Express, 17,  9112–9125, <a href="https://doi.org/10.1364/OE.17.009112" target="_blank">https://doi.org/10.1364/OE.17.009112</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>Riedi et al.(2010)</label><mixed-citation>
      
Riedi, J., Marchant, B., Platnick, S., Baum, B. A., Thieuleux, F., Oudard, C., Parol, F., Nicolas, J.-M., and Dubuisson, P.: Cloud thermodynamic phase inferred from merged POLDER and MODIS data, Atmos. Chem. Phys., 10, 11851–11865, <a href="https://doi.org/10.5194/acp-10-11851-2010" target="_blank">https://doi.org/10.5194/acp-10-11851-2010</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>Rodriguez et al.(2022)</label><mixed-citation>
      
Rodriguez, J., Lew-Yan-Voon, L., Martins, R., and Morel, O.: A Practical  Calibration Method for RGB Micro-Grid Polarimetric Cameras, IEEE Robotics and  Automation Letters, 7, 9921–9928, <a href="https://doi.org/10.1109/LRA.2022.3192655" target="_blank">https://doi.org/10.1109/LRA.2022.3192655</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>Smit et al.(2019)</label><mixed-citation>
      
Smit, J. M., Rietjens, J. H. H., van Harten, G., Noia, A. D., Laauwen, W.,  Rheingans, B. E., Diner, D. J., Cairns, B., Wasilewski, A., Knobelspiesse,  K. D., Ferrare, R., and Hasekamp, O. P.: SPEX airborne spectropolarimeter  calibration and performance, Appl. Optics, 58, 5695–5719,  <a href="https://doi.org/10.1364/AO.58.005695" target="_blank">https://doi.org/10.1364/AO.58.005695</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib59"><label>Sony Semiconductor Solutions Corporation(2023)</label><mixed-citation>
      
Sony Semiconductor Solutions Corporation: Polarization Image Sensor,
<a href="https://www.sony-semicon.com/en/products/is/industry/polarization.html" target="_blank"/> (last access: 17 July 2023), 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib60"><label>Stevens et al.(2021)</label><mixed-citation>
      
Stevens, B., Bony, S., Farrell, D., Ament, F., Blyth, A., Fairall, C., Karstensen, J., Quinn, P. K., Speich, S., Acquistapace, C., Aemisegger, F., Albright, A. L., Bellenger, H., Bodenschatz, E., Caesar, K.-A., Chewitt-Lucas, R., de Boer, G., Delanoë, J., Denby, L., Ewald, F., Fildier, B., Forde, M., George, G., Gross, S., Hagen, M., Hausold, A., Heywood, K. J., Hirsch, L., Jacob, M., Jansen, F., Kinne, S., Klocke, D., Kölling, T., Konow, H., Lothon, M., Mohr, W., Naumann, A. K., Nuijens, L., Olivier, L., Pincus, R., Pöhlker, M., Reverdin, G., Roberts, G., Schnitt, S., Schulz, H., Siebesma, A. P., Stephan, C. C., Sullivan, P., Touzé-Peiffer, L., Vial, J., Vogel, R., Zuidema, P., Alexander, N., Alves, L., Arixi, S., Asmath, H., Bagheri, G., Baier, K., Bailey, A., Baranowski, D., Baron, A., Barrau, S., Barrett, P. A., Batier, F., Behrendt, A., Bendinger, A., Beucher, F., Bigorre, S., Blades, E., Blossey, P., Bock, O., Böing, S., Bosser, P., Bourras, D., Bouruet-Aubertot, P., Bower, K., Branellec, P., Branger, H., Brennek, M., Brewer, A., Brilouet , P.-E., Brügmann, B., Buehler, S. A., Burke, E., Burton, R., Calmer, R., Canonici, J.-C., Carton, X., Cato Jr., G., Charles, J. A., Chazette, P., Chen, Y., Chilinski, M. T., Choularton, T., Chuang, P., Clarke, S., Coe, H., Cornet, C., Coutris, P., Couvreux, F., Crewell, S., Cronin, T., Cui, Z., Cuypers, Y., Daley, A., Damerell, G. M., Dauhut, T., Deneke, H., Desbios, J.-P., Dörner, S., Donner, S., Douet, V., Drushka, K., Dütsch, M., Ehrlich, A., Emanuel, K., Emmanouilidis, A., Etienne, J.-C., Etienne-Leblanc, S., Faure, G., Feingold, G., Ferrero, L., Fix, A., Flamant, C., Flatau, P. J., Foltz, G. R., Forster, L., Furtuna, I., Gadian, A., Galewsky, J., Gallagher, M., Gallimore, P., Gaston, C., Gentemann, C., Geyskens, N., Giez, A., Gollop, J., Gouirand, I., Gourbeyre, C., de Graaf, D., de Groot, G. E., Grosz, R., Güttler, J., Gutleben, M., Hall, K., Harris, G., Helfer, K. C., Henze, D., Herbert, C., Holanda, B., Ibanez-Landeta, A., Intrieri, J., Iyer, S., Julien, F., Kalesse, H., Kazil, J., Kellman, A., Kidane, A. T., Kirchner, U., Klingebiel, M., Körner, M., Kremper, L. A., Kretzschmar, J., Krüger, O., Kumala, W., Kurz, A., L'Hégaret, P., Labaste, M., Lachlan-Cope, T., Laing, A., Landschützer, P., Lang, T., Lange, D., Lange, I., Laplace, C., Lavik, G., Laxenaire, R., Le Bihan, C., Leandro, M., Lefevre, N., Lena, M., Lenschow, D., Li, Q., Lloyd, G., Los, S., Losi, N., Lovell, O., Luneau, C., Makuch, P., Malinowski, S., Manta, G., Marinou, E., Marsden, N., Masson, S., Maury, N., Mayer, B., Mayers-Als, M., Mazel, C., McGeary, W., McWilliams, J. C., Mech, M., Mehlmann, M., Meroni, A. N., Mieslinger, T., Minikin, A., Minnett, P., Möller, G., Morfa Avalos, Y., Muller, C., Musat, I., Napoli, A., Neuberger, A., Noisel, C., Noone, D., Nordsiek, F., Nowak, J. L., Oswald, L., Parker, D. J., Peck, C., Person, R., Philippi, M., Plueddemann, A., Pöhlker, C., Pörtge, V., Pöschl, U., Pologne, L., Posyniak, M., Prange, M., Quiñones Meléndez, E., Radtke, J., Ramage, K., Reimann, J., Renault, L., Reus, K., Reyes, A., Ribbe, J., Ringel, M., Ritschel, M., Rocha, C. B., Rochetin, N., Röttenbacher, J., Rollo, C., Royer, H., Sadoulet, P., Saffin, L., Sandiford, S., Sandu, I., Schäfer, M., Schemann, V., Schirmacher, I., Schlenczek, O., Schmidt, J., Schröder, M., Schwarzenboeck, A., Sealy, A., Senff, C. J., Serikov, I., Shohan, S., Siddle, E., Smirnov, A., Späth, F., Spooner, B., Stolla, M. K., Szkółka, W., de Szoeke, S. P., Tarot, S., Tetoni, E., Thompson, E., Thomson, J., Tomassini, L., Totems, J., Ubele, A. A., Villiger, L., von Arx, J., Wagner, T., Walther, A., Webber, B., Wendisch, M., Whitehall, S., Wiltshire, A., Wing, A. A., Wirth, M., Wiskandt, J., Wolf, K., Worbes, L., Wright, E., Wulfmeyer, V., Young, S., Zhang, C., Zhang, D., Ziemen, F., Zinner, T., and Zöger, M.: EUREC<sup>4</sup>A, Earth Syst. Sci. Data, 13, 4067–4119, <a href="https://doi.org/10.5194/essd-13-4067-2021" target="_blank">https://doi.org/10.5194/essd-13-4067-2021</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib61"><label>Toubbe et al.(1999)</label><mixed-citation>
      
Toubbe, B., Bailleul, T., Deuze, J., Goloub, P., Hagolle, O., and Herman, M.:  In-flight calibration of the POLDER polarized channels using the Sun's  glitter, IEEE T. Geosci. Remote, 37, 513–524, <a href="https://doi.org/10.1109/36.739104" target="_blank">https://doi.org/10.1109/36.739104</a>, 1999.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib62"><label>Tyo et al.(2009)</label><mixed-citation>
      
Tyo, J. S., LaCasse, C. F., and Ratliff, B. M.: Total elimination of sampling  errors in polarization imagery obtained with integrated microgrid  polarimeters, Opt. Lett., 34, 3187–3189, <a href="https://doi.org/10.1364/OL.34.003187" target="_blank">https://doi.org/10.1364/OL.34.003187</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib63"><label>van Diedenhoven et al.(2013)</label><mixed-citation>
      
van Diedenhoven, B., Cairns, B., Fridlind, A. M., Ackerman, A. S., and Garrett, T. J.: Remote sensing of ice crystal asymmetry parameter using multi-directional polarization measurements – Part 2: Application to the Research Scanning Polarimeter, Atmos. Chem. Phys., 13, 3185–3203, <a href="https://doi.org/10.5194/acp-13-3185-2013" target="_blank">https://doi.org/10.5194/acp-13-3185-2013</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib64"><label>Wirth et al.(2009)</label><mixed-citation>
      
Wirth, M., Fix, A., Mahnke, P., Schwarzer, H., Schrandt, F., and Ehret, G.: The airborne multi-wavelength water vapor differential absorption LIDAR  WALES: system design and performance, Appl. Phys. B-Lasers O., 96, 201–213, <a href="https://doi.org/10.1007/s00340-009-3365-7" target="_blank">https://doi.org/10.1007/s00340-009-3365-7</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib65"><label>Zhang et al.(2016)</label><mixed-citation>
      
Zhang, J., Luo, H., Hui, B., and Chang, Z.: Non-uniformity correction for  division of focal plane polarimeters with a calibration method, Appl. Optics,  55, 7236–7240, <a href="https://doi.org/10.1364/AO.55.007236" target="_blank">https://doi.org/10.1364/AO.55.007236</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib66"><label>Zhang(2000)</label><mixed-citation>
      
Zhang, Z.: A flexible new technique for camera calibration, IEEE T. Pattern Anal., 22, 1330–1334, <a href="https://doi.org/10.1109/34.888718" target="_blank">https://doi.org/10.1109/34.888718</a>, 2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib67"><label>Zinner et al.(2019)</label><mixed-citation>
      
Zinner, T., Schwarz, U., Kölling, T., Ewald, F., Jäkel, E., Mayer, B., and Wendisch, M.: Cloud geometry from oxygen-A-band observations through an aircraft side window, Atmos. Meas. Tech., 12, 1167–1181, <a href="https://doi.org/10.5194/amt-12-1167-2019" target="_blank">https://doi.org/10.5194/amt-12-1167-2019</a>, 2019.

    </mixed-citation></ref-html>--></article>