<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-17-2415-2024</article-id><title-group><article-title>Response of protonated, adduct, and fragmented ions in<?xmltex \hack{\break}?> Vocus proton-transfer-reaction time-of-flight mass<?xmltex \hack{\break}?> spectrometer (PTR-ToF-MS)</article-title><alt-title>Vocus proton-transfer-reaction time-of-flight mass spectrometer</alt-title>
      </title-group><?xmltex \runningtitle{Vocus proton-transfer-reaction time-of-flight mass spectrometer}?><?xmltex \runningauthor{F. Li et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff2">
          <name><surname>Li</surname><given-names>Fangbing</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Huang</surname><given-names>Dan Dan</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-2878-7469</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff2">
          <name><surname>Tian</surname><given-names>Linhui</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Yuan</surname><given-names>Bin</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3041-0329</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Tan</surname><given-names>Wen</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Zhu</surname><given-names>Liang</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Ye</surname><given-names>Penglin</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6">
          <name><surname>Worsnop</surname><given-names>Douglas</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff2">
          <name><surname>Hoi</surname><given-names>Ka In</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff2">
          <name><surname>Mok</surname><given-names>Kai Meng</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1 aff2">
          <name><surname>Li</surname><given-names>Yong Jie</given-names></name>
          <email>yongjieli@um.edu.mo</email>
        </contrib>
        <aff id="aff1"><label>1</label><institution>Department of Civil and Environmental Engineering, Faculty of Science and Technology,<?xmltex \hack{\break}?> University of Macau, Macao SAR, China</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Department of Ocean Science and Technology, and Centre for Regional Oceans, Faculty of Science and Technology, University of Macau, Macao SAR, China</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>State Environmental Protection Key Laboratory of Cause and Prevention of Urban Air Pollution Complex,<?xmltex \hack{\break}?> Shanghai Academy of Environmental Sciences, Shanghai, China</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>Institute for Environment and Climate Research, Jinan University, Guangzhou 510632, China</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>Tofwerk AG, Nanjing, China</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Aerodyne Research, Inc., Billerica, Massachusetts 01821, United States</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Yong Jie Li (yongjieli@um.edu.mo)</corresp></author-notes><pub-date><day>23</day><month>April</month><year>2024</year></pub-date>
      
      <volume>17</volume>
      <issue>8</issue>
      <fpage>2415</fpage><lpage>2427</lpage>
      <history>
        <date date-type="received"><day>3</day><month>January</month><year>2024</year></date>
           <date date-type="rev-request"><day>12</day><month>January</month><year>2024</year></date>
           <date date-type="rev-recd"><day>28</day><month>February</month><year>2024</year></date>
           <date date-type="accepted"><day>28</day><month>February</month><year>2024</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2024 Fangbing Li et al.</copyright-statement>
        <copyright-year>2024</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024.html">This article is available from https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d1e214">Volatile organic compounds (VOCs) affect secondary pollutant formation via active chemistry. Proton-transfer-reaction mass spectrometry (PTR-MS) is one of the most important techniques to study the highly variable spatial and temporal characteristics of VOCs. The response of protonated, adduct, and fragmented ions in PTR-MS in changing instrument settings and varying relative humidity (RH) requires rigorous characterization. Herein, we present dedicatedly designed laboratory experiments conducted to investigate the response of these ions for 21 VOCs, including 12 oxygenated VOCs and 2 nitriles, using the recently developed Vocus PTR-MS. Our results show that the focusing ion–molecule reactor (FIMR) axial voltage increases sensitivity by 3 to 4 orders of magnitude but does not significantly change the fractions of protonated ions. Reducing the FIMR pressure, however, substantially increases fragmentation. Applying a high radio frequency (RF) amplitude radially to the FIMR can enhance sensitivity by 1 to 2 orders of magnitude without affecting the protonated ion fractions. The change in big segmented quadrupole (BSQ) amplitude mainly affects sensitivity and protonated ion fraction by modifying ion transmission. The relationship between sensitivity and proton-transfer reaction rate constant is complicated by the influences from both ion transmission and protonated ion fraction. The protonated ions of most VOCs studied (19 out of 21) show less than 15 % variations in sensitivity as RH increases from <inline-formula><mml:math id="M1" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5% to <inline-formula><mml:math id="M2" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 %, except for some long-chain aldehydes which show a positive RH variation of up to 30 %. Our results suggest that the Vocus PTR-MS can reliably quantify the majority of VOCs under ambient conditions with varying RH. However, caution is advised for small oxygenates such as formaldehyde and methanol due to their low sensitivity and for long-chain aldehydes due to their slight RH dependence and fragmentation.</p>
  </abstract>
    
<funding-group>
<award-group id="gs1">
<funding-source>Fundo para o Desenvolvimento das Ciências e da Tecnologia</funding-source>
<award-id>FDCT0031/2023/AFJ</award-id>
</award-group>
<award-group id="gs2">
<funding-source>Universidade de Macau</funding-source>
<award-id>MYRG2022-00027-FST</award-id>
</award-group>
</funding-group>
</article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e240">Atmospheric volatile organic compounds (VOCs) affect atmospheric chemistry by forming secondary pollutants such as tropospheric O<inline-formula><mml:math id="M3" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> (Shao et al., 2016) and secondary organic aerosols (SOA) (Shrivastava et al., 2017). In addition to their low mixing ratios (parts per billion by volume, ppbv, or even lower), the spatial and temporal variabilities in atmospheric<?pagebreak page2416?> VOCs pose another analytical challenge to the study of their atmospheric occurrence, sources, and fates. Mass spectrometry (MS) techniques based on ion-molecule reactions (Ŝpaněl and Smith, 1996) or specifically proton-transfer reactions (Hansel et al., 1995; Lindinger et al., 1998) in a selected ion flow tube (SIFT) have been developed to provide fast-responding measurements of VOCs. These techniques, especially the proton-transfer-reaction MS (PTR-MS), have been widely used in VOC measurements in outdoor and indoor environments (Salazar Gómez et al., 2021; Sekimoto and Koss, 2021; Pagonis et al., 2019; Pleil et al., 2019; Claflin et al., 2021; Schripp et al., 2014; Jensen et al., 2021).</p>
      <p id="d1e252">Quantification of VOCs (denoted as M) by PTR-MS relies heavily on their proton-transfer reactions with the hydronium ion H<inline-formula><mml:math id="M4" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M5" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (Reaction R1). In early SIFT-MS studies where reagent ions include a multitude of H<inline-formula><mml:math id="M6" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M7" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>(H<inline-formula><mml:math id="M8" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O)<inline-formula><mml:math id="M9" display="inline"><mml:msub><mml:mi/><mml:mi>n</mml:mi></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>, 1, 2, 3, etc.) ion series (Ŝpaněl and Smith, 2000), proton-transfer reactions with more hydrated (<inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>≥</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>) hydronium ions (Reaction R2a) are also important for species with proton affinity (PA) larger than water clusters. In addition, ligand-switching reactions (Reaction R2b) and association reactions (Reaction R3, with N being N<inline-formula><mml:math id="M12" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> or O<inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are also common, leading to [MH<inline-formula><mml:math id="M14" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M15" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M16" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> instead of MH<inline-formula><mml:math id="M17" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>. Under these circumstances, the quantification of VOCs might be heavily influenced by the water vapor concentration or relative humidity (RH) of the sample. For instance, acetone concentrations in exhaled air were overestimated by 13 % even using both protonated (MH<inline-formula><mml:math id="M18" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and water adduct ([MH<inline-formula><mml:math id="M19" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M20" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M21" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> ions for quantification when water vapor varied in the range of (1–10) <inline-formula><mml:math id="M22" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 10<inline-formula><mml:math id="M23" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">12</mml:mn></mml:msup></mml:math></inline-formula> molecules cm<inline-formula><mml:math id="M24" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Ŝpaněl and Smith, 2000). A later study (Smith et al., 2001) showed that quantification of other oxygenated VOCs (OVOCs) such as ethyl acetate, diethyl ether, methanol, ethanol, and propanol by SIFT-MS also suffered from RH dependence to various degrees. 
          <disp-formula id="Ch1.R1" content-type="numbered reaction"><label>R1</label><mml:math id="M25" display="block"><mml:mrow><mml:mi mathvariant="normal">M</mml:mi><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow><mml:mo>→</mml:mo><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mrow></mml:math></disp-formula>
        <?xmltex \hack{\vspace{-8mm}}?><?xmltex \setcounter{equation}{1}?>

              <disp-formula id="Ch1.R2" specific-use="gather" content-type="subnumberedsingle reaction"><mml:math id="M26" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.R2.3"><mml:mtd><mml:mtext>R2a</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi mathvariant="normal">M</mml:mi><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow><mml:msub><mml:mfenced open="(" close=")"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mfenced><mml:mi>n</mml:mi></mml:msub><mml:mo>→</mml:mo><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:msub><mml:mfenced open="(" close=")"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mfenced><mml:mrow><mml:mi>n</mml:mi><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.R2.4"><mml:mtd><mml:mtext>R2b</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi mathvariant="normal">M</mml:mi><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow><mml:msub><mml:mfenced open="(" close=")"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mfenced><mml:mi>n</mml:mi></mml:msub><mml:mo>→</mml:mo><mml:msup><mml:mfenced close="]" open="["><mml:mrow><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mrow></mml:mfenced><mml:mo>+</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:msub><mml:mfenced open="(" close=")"><mml:mrow><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mfenced><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

          <?xmltex \hack{\vspace{-8mm}}?>
          <disp-formula id="Ch1.R5" content-type="numbered reaction"><label>R3</label><mml:math id="M27" display="block"><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:mi mathvariant="normal">N</mml:mi></mml:mrow><mml:mo>→</mml:mo><mml:msup><mml:mfenced close="]" open="["><mml:mrow><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mrow></mml:mfenced><mml:mo>+</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:mi mathvariant="normal">N</mml:mi></mml:mrow></mml:math></disp-formula>
        ​​​​​​​For PTR-MS that normally uses the MH<inline-formula><mml:math id="M28" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> for quantification, RH dependence was also widely reported. For instance, Warneke et al. (2001) reported that the sensitivity of benzene in PTR-MS decreased significantly with the increase in RH, while Steinbacher et al. (2004) suggested a slight decrease with the increase in RH. Quantification of biogenic volatile organic compounds (BVOCs) was also reported to be slightly affected by RH (Kari et al., 2018). The RH dependence stems from the change in reagent ion distribution, i.e., among H<inline-formula><mml:math id="M29" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M30" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and H<inline-formula><mml:math id="M31" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M32" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>(H<inline-formula><mml:math id="M33" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O)<inline-formula><mml:math id="M34" display="inline"><mml:msub><mml:mi/><mml:mi>n</mml:mi></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>≥</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>), which can lead to the overestimation or underestimation of VOCs if such a dependence is strong because ambient RH is deemed highly variable. Therefore, RH-dependent calibrations for VOC measurements using PTR-MS were normally recommended (de Gouw and Warneke, 2007; Inomata et al., 2008; Sinha et al., 2009; Vlasenko et al., 2010; Cui et al., 2016; Michoud et al., 2018).</p>
      <p id="d1e763">Another complication in VOC measurements using SIFT-MS or PTR-MS is that, due to the nucleophilicity of the oxygen atom, protonated OVOCs dehydrate and form fragmented ions (Reaction R4). This reaction often occurs in heavy alcohols, aldehydes, and carboxylic acids (Španěl et al., 1997; Ŝpaněl and Smith, 1998; Hartungen et al., 2004; Baasandorj et al., 2015).
          <disp-formula id="Ch1.R6" content-type="numbered reaction"><label>R4</label><mml:math id="M36" display="block"><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup><mml:mo>→</mml:mo><mml:msup><mml:mfenced close="]" open="["><mml:mrow><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>-</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mrow></mml:mfenced><mml:mo>+</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:mrow></mml:math></disp-formula>
        In addition, cleavage on the C–C bond of the protonated ion (R5) is also possible, especially for alkyl-substituted VOCs under high-energy conditions (e.g., a high <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio, which is the reduced electric field parameter with <inline-formula><mml:math id="M38" display="inline"><mml:mi>E</mml:mi></mml:math></inline-formula> being the electric field and <inline-formula><mml:math id="M39" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> the number density of the gas in the drift tube).
          <disp-formula id="Ch1.R7" content-type="numbered reaction"><label>R5</label><mml:math id="M40" display="block"><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup><mml:mo>→</mml:mo><mml:msup><mml:mfenced close="]" open="["><mml:mrow><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mrow class="chem"><mml:mi mathvariant="normal">C</mml:mi></mml:mrow><mml:mi>x</mml:mi></mml:msub><mml:msub><mml:mrow class="chem"><mml:mi mathvariant="normal">H</mml:mi></mml:mrow><mml:mi>y</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mo>+</mml:mo></mml:msup><mml:mo>+</mml:mo><mml:msub><mml:mrow class="chem"><mml:mi mathvariant="normal">C</mml:mi></mml:mrow><mml:mi>x</mml:mi></mml:msub><mml:msub><mml:mrow class="chem"><mml:mi mathvariant="normal">H</mml:mi></mml:mrow><mml:mi>y</mml:mi></mml:msub></mml:mrow></mml:math></disp-formula>
        For instance, at an <inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio of 120 townsend (Td), substituted monocyclic aromatic compounds such as ethylbenzene and propylbenzene start to fragment into a benzenium ion (C<inline-formula><mml:math id="M42" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M43" display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mn mathvariant="normal">7</mml:mn><mml:mo>+</mml:mo></mml:msubsup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (de Gouw et al., 2003; Gueneron et al., 2015).</p>
      <p id="d1e916">A newly designed focusing ion-molecule reactor (FIMR) was used for PTR-MS, termed Vocus PTR-MS, and has been shown to have little RH dependence for the protonated ion because of the high concentration of water vapor introduced into the FIMR (Krechmer et al., 2018). The concentration of hydronium ion (H<inline-formula><mml:math id="M44" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> in the FIMR is high enough to be maintained at a constant level and dominate over other side reactions, thereby minimizing the RH dependence for VOC measurement. Yet, the formation of adduct ions and fragmented ions in Vocus PTR-MS as a function of RH has not been fully scrutinized, hindering a complete understanding of the ion chemistry in the Vocus PTR-MS and potential cross interference when measuring ambient air with complex VOC mixtures. Herein, we conducted experiments on the effects of instrument settings and RH variations on the quantification of 21 VOCs, including 12 OVOCs and 2 nitriles, using a Vocus PTR-MS. The responses of protonated ions (MH<inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, adduct ions ([MH<inline-formula><mml:math id="M47" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M48" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and fragmented ions ([MH–H<inline-formula><mml:math id="M50" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M51" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> or [MH<inline-formula><mml:math id="M52" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M53" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M54" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> to these VOCs were investigated as a function of instrument setting and RH. Results are interpreted based on the PA values and/or proton-transfer reaction rate constants (<inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Some caveats to using the Vocus PTR-MS to measure VOCs, especially OVOCs, are also provided.</p><?xmltex \hack{\newpage}?>
</sec>
<?pagebreak page2417?><sec id="Ch1.S2">
  <label>2</label><title>Methodology</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Instrument settings</title>
      <p id="d1e1066">Experiments were performed with a Vocus proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS, Vocus 2R, TOFWERK AG, Thun, Switzerland), hereinafter referred to as Vocus. The Vocus consists of (i) a discharge ion source, (ii) a focusing ion-molecule reactor (FIMR), (iii) a big segmented quadrupole (BSQ), (iv) a series of direct current (DC) optics that further focus and accelerate the primary beam (PB), and (v) a time-of-flight (ToF) mass analyzer (Krechmer et al., 2018). The ion source is a plasma discharge composed of two conical surfaces. Water vapor is supplied by purging 20 to 30 mL of Milli-Q water and is ionized by plasma discharge. The reagent ions pass through a ring offset from the central axis so that the photons generated by the discharge cannot enter. The drift tube was improved by replacing the stacked ring electrodes of the traditional PTR-MS with a FIMR, which is a glass tube with a resistive coating on the inner surface, and a quadrupole with a radio frequency (RF) electric field was applied. The FIMR increases ion transmission by a factor of 7 to 9 and sensitivity by more than 1 order of magnitude (Krechmer et al., 2018). Moreover, the mean kinetic energy of H<inline-formula><mml:math id="M57" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M58" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> is increased by 3 times, and the formation of more hydrated hydronium ions is reduced, suppressing RH dependence for most VOCs measured  (Krechmer et al., 2018). Meanwhile, the mean kinetic energy of VOCs measured is not significantly increased, thereby minimizing fragmentation (Krechmer et al., 2018). The ToF mass analyzer offers a mass-resolving power of 12 000 at a mass-to-charge ratio (<inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of 107 thomson (Th).</p>
      <p id="d1e1101">In our experiments, sample air was drawn into the instrument using perfluoroalkoxy (PFA) Teflon tubing of <inline-formula><mml:math id="M60" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 0.5 m length and 1/4 in. outer diameter, with a flow rate of 0.5 L min<inline-formula><mml:math id="M61" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Most of the sample air was directed to the exhaust, while the actual flow into the FIMR was around 0.15 L min<inline-formula><mml:math id="M62" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. In typical experiments, the FIMR was operated at a pressure of 2.0 mbar and a temperature of 373.15 K. The axial and radial voltages were normally set to 625 and 500 V, respectively, unless stated otherwise.</p>
      <p id="d1e1135">We also performed experiments by varying the instrument settings such as the FIMR axial voltage (<inline-formula><mml:math id="M63" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>) and pressure (<inline-formula><mml:math id="M64" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>), both of which affect the <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio, as well as RF and BSQ amplitudes to investigate how protonated, adduct, and fragmented ions respond to those changes. These experiments were performed under dry (RH <inline-formula><mml:math id="M66" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 %) conditions, and the concentrations were approximately 12 ppbv for most VOCs (except for <inline-formula><mml:math id="M67" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene at about 1.2 ppbv). The instrument settings were varied by (1) changing the FIMR axial voltage from 260 to 700 V, (2) changing the pressure in the FIMR from 1.5 to 3.5 mbar, (3) changing the RF amplitude from 13 to 500 V (with <inline-formula><mml:math id="M68" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula> of 2.0 or 3.5 mbar), and (4) changing the BSQ voltage from 50 to 300 V (with <inline-formula><mml:math id="M69" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula> of 2.0 or 3.5 mbar). The other instrument settings were fixed as the default values while changing the tested ones. Specifically, the RF amplitude was at 500 V and the BSQ amplitude was at 300 V when changing <inline-formula><mml:math id="M70" display="inline"><mml:mi>E</mml:mi></mml:math></inline-formula> (i.e., <inline-formula><mml:math id="M71" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>) and <inline-formula><mml:math id="M72" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> (i.e., <inline-formula><mml:math id="M73" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>), and an <inline-formula><mml:math id="M74" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio of 142 Td was used when changing RF and BSQ amplitudes (Table S1 in the Supplement).</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Experimental setup</title>
      <p id="d1e1242">The VOCs (Table S2 and Fig. 1) in mixtures from two cylinders were separately delivered to the dilution and/or RH control setup (Fig. S1). Dilution air was generated from a zero-air generator (Environics series 7000, Environics Analytics Group Ltd., Canada). Gas cylinder I (Table 1, Apel-Riemer Environmental Inc., United States; valid for 12 months) contains mainly hydrocarbons, while gas cylinder II (Table 1, Linde Gas, United States; valid for 12 months) contains mainly OVOCs and nitriles. Most VOCs in the cylinders are at approximately 1000 ppbv, except for <inline-formula><mml:math id="M75" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene, which is at approximately 100 ppbv. Table S2 shows their Chemical Abstracts Service (CAS) numbers and <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values of the protonated ions (MH<inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, as well as PA and <inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values. According to their functional groups, the 21 VOCs are grouped into nine categories, and Fig. 1 shows their structures. Note that although <inline-formula><mml:math id="M79" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-butanal and methyl ethyl ketone are isomers, they are in different cylinders and measured separately and thus will not interfere with each other.</p>
      <p id="d1e1294">Dry experiments were performed by diluting the VOCs from the cylinders with dry zero air with seven concentrations from 0 to approximately 22 ppbv (or approximately 2 ppbv for <inline-formula><mml:math id="M80" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene). For each concentration step, measurements lasted for about half an hour for gas cylinder I with hydrocarbons but about 2 h for gas cylinder II with OVOCs and nitriles. The 2 h stabilization time for cylinder II, which contained mainly OVOCs and nitriles, should be sufficient because even with half-an-hour stabilization time for cylinder I, the overlapping species acetone and acetaldehyde showed deviations of less than <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn></mml:mrow></mml:math></inline-formula> % in sensitivity. Other measures, such as minimizing the length of the Teflon tube at the inlet (less than 30 cm), were also undertaken to allow the fast establishment of equilibrium-state concentrations for OVOCs. In RH-dependent experiments (Fig. S1), dilution was made by RH-conditioned air produced from a humidity generator (OHG-4, Owlstone, United States). The accuracy of the RH sensor (RH-USB Probe, Omega) is within 4 % of RH. Nine RH ramping steps from <inline-formula><mml:math id="M82" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 % to <inline-formula><mml:math id="M83" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 % with approximately 10 % intervals were used, and the VOCs were set with four concentrations from 0 to approximately 12 ppbv (or approximately 1.2 ppbv for <inline-formula><mml:math id="M84" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene). After the initial equilibration of 0.5 h under dry conditions (RH <inline-formula><mml:math id="M85" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 %), each RH ramping lasted for 15 min. Triplicate experiments were performed for the highest concentration.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e1345">Names, structures, and grouping of the 21 VOCs in this study. These VOCs were prepared in two gas standard cylinders (I and II) with mixing ratios of <inline-formula><mml:math id="M86" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1000 ppbv (<inline-formula><mml:math id="M87" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 100 ppbv for <inline-formula><mml:math id="M88" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene) balanced by N<inline-formula><mml:math id="M89" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>. Acetaldehyde and acetone are present in both gas standard cylinders, with concentrations differing by <inline-formula><mml:math id="M90" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 5 %. <inline-formula><mml:math id="M91" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-Butanal and methyl ethyl ketone are isomers but are in different gas standard cylinders.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024-f01.png"/>

        </fig>

<?xmltex \hack{\newpage}?>
</sec>
<?pagebreak page2418?><sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Data analysis</title>
      <p id="d1e1409">The Vocus data were analyzed with the manufacturer-supplied software package Tofware (v3.2.3) based on IGOR Pro (WaveMetrics). Peak fitting was performed using Tofware routines and the measured <inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values of the pronated ions (MH<inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are shown in Table S2 together with their exact <inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values. In addition to MH<inline-formula><mml:math id="M95" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, we also looked for adduct ions ([MH<inline-formula><mml:math id="M96" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M97" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and fragmented ions ([MH<inline-formula><mml:math id="M99" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M100" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M101" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> or [MH<inline-formula><mml:math id="M102" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M103" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M104" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, since those ions are also anticipated for VOCs, especially OVOCs, in PTR-MS measurements (Pagonis et al., 2019). Although the VOCs were in mixtures and showed ensemble mass spectra, we constructed the mass spectrum for each VOC by plotting their identified adduct or fragmented ions alongside the protonated ions, as shown in Figs. S2–S4 in the Supplement. Their percentage contributions are presented in Fig. 2 and numerically in Table S4.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e1551">The average signal percentages of protonated, adduct, and fragmented ions at a concentration of <inline-formula><mml:math id="M106" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 12 ppbv (<inline-formula><mml:math id="M107" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 1.2 ppbv for <inline-formula><mml:math id="M108" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene).</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024-f02.png"/>

        </fig>

      <p id="d1e1581">For both dry and RH-dependent experiments from the 1 min averages from 1 Hz data sets, the last five points were averaged to obtain stable signals. Figure S5 shows the time series of selected hydrocarbons (groups A1 and A2, aromatic hydrocarbons and terpenoids, Fig. S5a) and OVOCs (groups B2 and B5, long-chain and aromatic aldehydes, Fig. S5b) during dry experiments with concentration stepping. Figure S6 shows the time series of protonated ions (MH<inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, adduct ions ([MH<inline-formula><mml:math id="M110" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M111" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and fragmented ions ([MH–H<inline-formula><mml:math id="M113" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M114" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and/or [MH<inline-formula><mml:math id="M115" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M116" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M117" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M118" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>) for <inline-formula><mml:math id="M119" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-butanal, pentanal, and hexaldehyde, whose adduct and fragmented ions contributed substantially to the total signals (Fig. 2 and Table S4). Some dealkylated fragments ([MH<inline-formula><mml:math id="M120" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M121" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M122" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M123" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of long-chain aldehydes (e.g., <inline-formula><mml:math id="M124" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-butanal and pentanal) might overlap with the protonated ions ([MH]<inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of unsaturated aldehydes (i.e., acrolein and methacrolein). Since the intensities of the former are expected to be low by analogy with that of hexaldehyde (<inline-formula><mml:math id="M126" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 2 %, Fig. 2), however, the ions at those <inline-formula><mml:math id="M127" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>/<inline-formula><mml:math id="M128" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> values are only considered to be the protonated ions of unsaturated aldehydes (the latter).</p>
      <p id="d1e1764">Similarly to RH-dependent experiments, the duration of each instrument setting experiment was 15 min. The signal intensities, as well as the relative proportions of MH<inline-formula><mml:math id="M129" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, [MH <inline-formula><mml:math id="M130" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> H<inline-formula><mml:math id="M131" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M132" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, and [MH <inline-formula><mml:math id="M133" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> H<inline-formula><mml:math id="M134" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M135" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (and/or [MH <inline-formula><mml:math id="M136" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula> C<inline-formula><mml:math id="M137" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M138" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M139" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>), were presented in Figs. S7 to S10 for two representative hydrocarbons (<inline-formula><mml:math id="M140" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-pinene and 1,2,4-trimethylbenzene) and two OVOCs (acetone and hexaldehyde). These measurements were conducted across varying axial voltages and pressures (both factors that influence the <inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio) within the FIMR, as well as with adjustments to the RF amplitude and BSQ amplitude. The reduced electric field parameter (<inline-formula><mml:math id="M142" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio) was estimated by comparing the signal fraction of fragment of <inline-formula><mml:math id="M143" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-pinene in Materić et al. (2017), in which detailed examination of fragment signal fraction at different <inline-formula><mml:math id="M144" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio was performed (Fig. S11).</p>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><title>Sensitivity estimation</title>
      <p id="d1e1920">The formation of the protonated ion MH<inline-formula><mml:math id="M145" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> via Reaction (R1) is desirable for quantification of VOCs, which is described by the kinetics of the proton-transfer reaction (de Gouw and Warneke, 2007; Yuan et al., 2017): 
            <disp-formula id="Ch1.E8" content-type="numbered"><label>1</label><mml:math id="M146" display="block"><mml:mrow><mml:mfenced close="]" open="["><mml:mrow><mml:msup><mml:mrow class="chem"><mml:mi mathvariant="normal">MH</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:mfenced><mml:mo>=</mml:mo><mml:msub><mml:mfenced close="]" open="["><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mfenced open="(" close=")"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mi>k</mml:mi><mml:mo>[</mml:mo><mml:mi mathvariant="normal">M</mml:mi><mml:mo>]</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msup></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where [MH<inline-formula><mml:math id="M147" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>] is the number concentration of the protonated ion and [H<inline-formula><mml:math id="M148" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M149" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>]<inline-formula><mml:math id="M150" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:math></inline-formula> that of the initial hydronium ion, <inline-formula><mml:math id="M151" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> is the rate constant of R1 (<inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, [<inline-formula><mml:math id="M153" display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>] is the number concentration of the target VOCs in the sample air, and <inline-formula><mml:math id="M154" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> is the reaction time in the FIMR. Two conditions allow simplification of Eq. (1) to Eq. (2) below for the easy quantification of VOCs: (1) the term <inline-formula><mml:math id="M155" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula>[M]<inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> is much smaller than 1, such that R1 can be considered essentially first-order, and (2) H<inline-formula><mml:math id="M157" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M158" display="inline"><mml:msup><mml:mi/><mml:mo>+<?pagebreak page2419?></mml:mo></mml:msup></mml:math></inline-formula> is not significantly depleted and remains more or less constant after the FIMR. Compared with traditional ion sources, the Vocus ion source produces sufficient H<inline-formula><mml:math id="M159" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M160" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (Krechmer et al., 2018). Ambient levels of ppbv (or less) for [<inline-formula><mml:math id="M161" display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula>] (<inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">10</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> molecule cm<inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> generally fulfill such requirements, given that <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is on the order of 10<inline-formula><mml:math id="M165" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> cm<inline-formula><mml:math id="M166" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> molecule<inline-formula><mml:math id="M167" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> s<inline-formula><mml:math id="M168" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and <inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> is on the order of 10<inline-formula><mml:math id="M170" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> s (Ellis and Mayhew, 2014). Therefore,
            <disp-formula id="Ch1.E9" content-type="numbered"><label>2</label><mml:math id="M171" display="block"><mml:mrow><mml:mfenced close="]" open="["><mml:mrow><mml:msup><mml:mrow class="chem"><mml:mi mathvariant="normal">MH</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:mfenced><mml:mo>=</mml:mo><mml:mfenced open="[" close="]"><mml:mrow><mml:msup><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:mfenced><mml:mi>k</mml:mi><mml:mfenced close="]" open="["><mml:mi>M</mml:mi></mml:mfenced><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where [H<inline-formula><mml:math id="M172" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M173" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>] is the number concentration of hydronium ions after the FIMR (i.e., being detected in the mass spectrometer). Then,
            <disp-formula id="Ch1.E10" content-type="numbered"><label>3</label><mml:math id="M174" display="block"><mml:mrow><mml:mfenced open="[" close="]"><mml:mi>M</mml:mi></mml:mfenced><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:msup><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mi>k</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M175" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:msup><mml:mrow class="chem"><mml:mi mathvariant="normal">MH</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:msup><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> are signal intensities of the protonated ion and the hydronium ion, respectively.</p>
      <p id="d1e2382">In general, the sensitivity (<inline-formula><mml:math id="M177" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>) of PTR-MS for quantification of VOCs is defined as the ratio between the signal intensity <inline-formula><mml:math id="M178" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> normalized by 10<inline-formula><mml:math id="M179" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">6</mml:mn></mml:msup></mml:math></inline-formula> cps (counts per second) of <inline-formula><mml:math id="M180" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and 1 ppbv (10<inline-formula><mml:math id="M181" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> mol mol<inline-formula><mml:math id="M182" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of VOCs, i.e.,
            <disp-formula id="Ch1.E11" content-type="numbered"><label>4</label><mml:math id="M183" display="block"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mrow><mml:msup><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">6</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mfenced close="]" open="["><mml:mi>M</mml:mi></mml:mfenced></mml:mrow><mml:mi>N</mml:mi></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">9</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M184" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> is the number density of air (N in Reaction R3) in the FIMR. The sensitivity <inline-formula><mml:math id="M185" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> is thus expressed as a normalized signal per ppbv, having a unit of ncps ppbv<inline-formula><mml:math id="M186" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Combining Eqs. (3) and (4) yields
            <disp-formula id="Ch1.E12" content-type="numbered"><label>5</label><mml:math id="M187" display="block"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>×</mml:mo><mml:mi>N</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>×</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where 10<inline-formula><mml:math id="M188" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>×</mml:mo><mml:mi>N</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> is specific to the instrument settings. Equation (5) dictates that <inline-formula><mml:math id="M189" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> should have a linear relationship with the proton-transfer reaction rate constant (<inline-formula><mml:math id="M190" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> if the instrument settings are fixed and can be utilized to predict <inline-formula><mml:math id="M191" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> if <inline-formula><mml:math id="M192" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values are known (Ellis and Mayhew, 2014).</p>
      <p id="d1e2648">In reality, however, the quantification of VOCs using MH<inline-formula><mml:math id="M193" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> from PTR-MS measurements is complicated by (1) formation of adduct (e.g., with H<inline-formula><mml:math id="M194" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O) and fragmented (e.g., dehydration) ions and (2) discriminated transmission for MH<inline-formula><mml:math id="M195" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions with different <inline-formula><mml:math id="M196" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values  (de Gouw and Warneke, 2007; Yuan et al., 2017). The fraction of MH<inline-formula><mml:math id="M197" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> in all related ions (<inline-formula><mml:math id="M198" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and the relative transmission efficiency (<inline-formula><mml:math id="M199" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mi mathvariant="normal">O</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are used to account for these two effects, respectively.
            <disp-formula id="Ch1.E13" content-type="numbered"><label>6</label><mml:math id="M200" display="block"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>×</mml:mo><mml:mi>N</mml:mi><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:msup><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:msub><mml:mo>×</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:math></disp-formula>
          In our study, the sensitivity is expressed as the slope of signal intensity (in counts per second, cps) vs. concentration (in ppbv) having a unit of cps ppbv<inline-formula><mml:math id="M201" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (Fig. S12). Signal normalization to H<inline-formula><mml:math id="M202" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M203" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (ncps) was not adopted because the signal of H<inline-formula><mml:math id="M204" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M205" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (<inline-formula><mml:math id="M206" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">19</mml:mn></mml:mrow></mml:math></inline-formula> Th) was substantially suppressed with low transmission (see below) for those ions with small <inline-formula><mml:math id="M207" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values (but too-high intensities) to minimize ion currents.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Effects of instrumental settings on the ion signals</title>
      <p id="d1e2915">An increase in the <inline-formula><mml:math id="M208" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio from 48 to 142 Td manifested by the increases in the FIMR axial voltage (<inline-formula><mml:math id="M209" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>, with front from 226 to 666 V and back keeping at 34 V) led to drastic increases in MH<inline-formula><mml:math id="M210" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> signal intensity by 3 to 4 orders of magnitude for all VOCs studied (Fig. 3a). Such increases were also observed for adduct and fragmented ions (Figs. S7–S10), albeit to different extents. It has been shown that increasing the axial voltage in the FIMR can substantially increase protonated ion signals mainly due to three reasons (Krechmer et al., 2018; de Gouw and Warneke, 2007). First, a high FIMR axial voltage can accelerate the ions and thus reduce their residence time, thereby preventing diffusional loss. Second, the high voltage in the FIMR significantly increases the concentration of all reagent ions (Fig. S13). Lastly, at high voltages, reactions between some OVOCs (such as acetone) and H<inline-formula><mml:math id="M211" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M212" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> lead to more protonated ions (MH<inline-formula><mml:math id="M213" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> instead of adduct ions ([MH<inline-formula><mml:math id="M214" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M215" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M216" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> through ligand-switching reactions (Reaction R2b). This last result was believed to be less significant for species that do not readily react with H<inline-formula><mml:math id="M217" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M218" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>(H<inline-formula><mml:math id="M219" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O)<inline-formula><mml:math id="M220" display="inline"><mml:msub><mml:mi/><mml:mi>n</mml:mi></mml:msub></mml:math></inline-formula> (such as aromatics and terpenoids).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e3044">The ratio of the logarithm of intensity (panels <bold>a</bold>, <bold>b</bold>, and <bold>c</bold>) and the difference in fractional signal of the protonated ion (MH<inline-formula><mml:math id="M221" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> among all ions (panels <bold>d</bold>, <bold>e</bold>, and <bold>f</bold>) when changing axial voltage (<inline-formula><mml:math id="M222" display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>) or FIMR pressure (<inline-formula><mml:math id="M223" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>) (panels <bold>a</bold> and <bold>d</bold>), RF amplitude (panels <bold>b</bold> and <bold>e</bold>), and BSQ amplitude (panels <bold>c</bold> and <bold>f</bold>). The ratios were taken after taking the logarithm of the signal intensities of MH<inline-formula><mml:math id="M224" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> on the right-hand side of the instrument setting (after the arrow) to that on the left-hand side of the instrument setting stated in the panel label; likewise, the fractional differences are the fractions of the MH<inline-formula><mml:math id="M225" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> signal among the protonated, fragmented, and adduct signals under these two instrument settings.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024-f03.png"/>

        </fig>

      <?pagebreak page2420?><p id="d1e3135">To investigate whether the desired MH<inline-formula><mml:math id="M226" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> is indeed more favorably formed by suppressing Reaction (R2b) under high axial voltages, we plot the differences in the signal fractions of MH<inline-formula><mml:math id="M227" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> between axial voltages of 666 V and 226 V (Fig. 3d). The results show that about one-third of the 21 VOCs do not have significant differences in the signal fractions: most VOCs in this one-third have MH<inline-formula><mml:math id="M228" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> as the sole or dominating ion observed (cf. Fig. 2). Meanwhile, about one-third of the VOCs show negative differences (i.e., decreasing MH<inline-formula><mml:math id="M229" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> fractions) of up to 0.2, including the two hydrocarbons and two OVOCs shown in panel d of Figs. S7–S10. The remaining one-third of the VOCs show positive differences (i.e., increasing MH<inline-formula><mml:math id="M230" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> fractions) of up to 0.3, mainly for unsaturated or aromatic aldehydes, as well as nitriles (Fig. 3d). A closer inspection of the fractional changes as axial voltage increases for acetone (Fig. S9d) and hexaldehyde (Fig. S10d) reveals that the fractions of both MH<inline-formula><mml:math id="M231" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and [MH<inline-formula><mml:math id="M232" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M233" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M234" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> decrease, while those of fragmented ions ([MH<inline-formula><mml:math id="M235" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M236" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M237" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and/or [MH<inline-formula><mml:math id="M238" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M239" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M240" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M241" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> increase. The relative decreases in the signal fractions of MH<inline-formula><mml:math id="M242" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (8 % for acetone and 51 % for hexaldehyde) are, however, much lower than those of [MH<inline-formula><mml:math id="M243" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M244" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M245" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (57 % for acetone and 80 % for hexaldehyde). These observations suggest that while fractions of both MH<inline-formula><mml:math id="M246" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and [MH<inline-formula><mml:math id="M247" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M248" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M249" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> decrease, the decreases in the adduct ion ([MH<inline-formula><mml:math id="M250" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M251" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M252" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are more significant. This supports the third explanation above that more H<inline-formula><mml:math id="M253" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M254" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (instead of H<inline-formula><mml:math id="M255" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M256" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>(H<inline-formula><mml:math id="M257" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O)<inline-formula><mml:math id="M258" display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi>n</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> at higher axial voltages react with these OVOCs. However, as the voltage increases, all ion signals increase (Figs. S7a–S10a). This observation illustrates that the ion acceleration and diffusion prevention should be the primary cause of signal enhancement at high axial voltages. Nevertheless, the signal fractions of the MH<inline-formula><mml:math id="M259" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> do not change substantially (within 30 %) as the FIMR axial voltage increases, making quantification reliable even for species with high signal contributions from adduct and fragmented ions (e.g., long-chain aldehydes, group B2; cf. Fig. 2).</p>
      <p id="d1e3447">The increase in <inline-formula><mml:math id="M260" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio by decreasing the FIMR pressure from 3.5 to 1.5 mbar increases signal intensities (Fig. S14a) of MH<inline-formula><mml:math id="M261" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> by less than 1 order of magnitude or even decreases those for some OVOCs such as long-chain aldehydes. The changes in the signal fractions of MH<inline-formula><mml:math id="M262" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (Fig. S14d), on the other hand, are more than those when changing axial voltages, especially for ketones, unsaturated aldehydes, aromatic aldehydes, and nitriles. The increase in pressure in the PTR reactor also favors the formation of reagent clusters H<inline-formula><mml:math id="M263" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M264" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>(H<inline-formula><mml:math id="M265" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O)<inline-formula><mml:math id="M266" display="inline"><mml:msub><mml:mi/><mml:mi>n</mml:mi></mml:msub></mml:math></inline-formula>, which leads to the formation of adduct ions (Wang et al., 2020). For OVOCs (acetone and hexaldehyde), the fractions of MH<inline-formula><mml:math id="M267" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> increase when FIMR pressure decreases from 3.5 to 2.5 mbar (<inline-formula><mml:math id="M268" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio from 162 to 95), which is accompanied by significant decreases in the adduct ion [MH<inline-formula><mml:math id="M269" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M270" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M271" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (Figs. S9j and S10j). This observation suggests less formation of adduct ions at lower FIMR pressures. A further decrease in FIMR pressure to 1.5 mbar, however, results in slight decreases in MH<inline-formula><mml:math id="M272" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> fractions in lieu of increases in fragmented ions [MH<inline-formula><mml:math id="M273" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M274" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M275" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and [MH<inline-formula><mml:math id="M276" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M277" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M278" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M279" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (Figs. S9j and S10j); for hydrocarbons <inline-formula><mml:math id="M280" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-pinene and 1,2,4-trimethylbenzene (Figs. S7j and S8j) that only have MH<inline-formula><mml:math id="M281" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and [MH<inline-formula><mml:math id="M282" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M283" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M284" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M285" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, continuous decreases in MH<inline-formula><mml:math id="M286" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> fractions and increases in [MH<inline-formula><mml:math id="M287" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M288" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M289" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M290" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> are observed for the whole range of FIMR pressure tested (3.5 to 1.5 mbar). A recent study using Vocus PTR-MS to measure organic peroxides also observed that less fragmented ions were formed under higher FIMR pressure (Li et al., 2022) presumably due to the efficient transfer of excess kinetic energy by frequent collisions at higher pressures. A medium FIMR pressure of 2.0 mbar was chosen to have relatively low fractions of both adduct ions ([MH<inline-formula><mml:math id="M291" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M292" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M293" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and fragmented ions ([MH<inline-formula><mml:math id="M294" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M295" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M296" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and [MH<inline-formula><mml:math id="M297" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M298" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M299" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M300" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e3819">The radial RF electric field in the FIMR is unique for the Vocus PTR-MS, which can (1) collimate the ions towards the central axis (especially heavier ions) and (2) increase the kinetic energy of the ions (especially for lighter ions) (Krechmer et al., 2018). These effects led to signals 1 to 1.5 orders of magnitude higher for MH<inline-formula><mml:math id="M301" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> at 2.0 mbar of FIMR pressure (Fig. 3b) and 1.5 to 2 orders of magnitude higher at 3.5 mbar (Fig. S14b) when the RF amplitude was changed from 13 to 500 V. The additional enhancement of signal intensity at a higher FIMR pressure (i.e., 3.5 mbar compared to 2.0 mbar) can be attributed to a longer residence time of the reagent ions (Krechmer et al., 2018). The more pronounced increase in kinetic energy for lighter ions (e.g., H<inline-formula><mml:math id="M302" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M303" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> than heavier ions (i.e., clusters H<inline-formula><mml:math id="M304" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M305" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>(H<inline-formula><mml:math id="M306" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O)<inline-formula><mml:math id="M307" display="inline"><mml:msub><mml:mi/><mml:mi>n</mml:mi></mml:msub></mml:math></inline-formula>) might imply the favorable formation of the protonated ion MH<inline-formula><mml:math id="M308" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> rather than adduct ions. The fractions of MH<inline-formula><mml:math id="M309" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> for different RF amplitudes do not change significantly (within <inline-formula><mml:math id="M310" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.2</mml:mn></mml:mrow></mml:math></inline-formula>) at either 2.0 mbar (Fig. 3e) or 3.5 mbar (Fig. S14e). This observation suggests that adding the RF can increase signal intensities by 1–2 orders of magnitude but does not affect the fractional signal for MH<inline-formula><mml:math id="M311" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, making it beneficial for accurate quantification.</p>
      <?pagebreak page2421?><p id="d1e3926">The BSQ amplitude above 100 V does not change the signal intensities significantly (Figs. 3c and S14c, as well as Fig. S7–S10). The BSQ ion guide provides a high-pass band filter to reduce the number of ions (thus signal intensity) of low <inline-formula><mml:math id="M312" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>/<inline-formula><mml:math id="M313" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> values (especially for reagent ions, H<inline-formula><mml:math id="M314" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M315" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, with high ion currents), preventing the fast degradation of the microchannel plate (MCP) detector (Krechmer et al., 2018). As will be discussed below, this high-pass band filter leads to lower ion transmission efficiency (<inline-formula><mml:math id="M316" display="inline"><mml:mo lspace="0mm">&lt;</mml:mo></mml:math></inline-formula> 1) for ions with smaller <inline-formula><mml:math id="M317" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values. Therefore, the signal reduction when the BSQ amplitude increases from 100 to 300 V is more obvious for small analytes such as formaldehyde, acetonitrile, and methanol (Figs. 3c and S14c). For other analytes whose fragmented ions have <inline-formula><mml:math id="M318" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values of less than 60 Th, the signal fractions of MH<inline-formula><mml:math id="M319" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> would also be affected (Figs. 3f and S14f). For example, the intensities of fragmented ions [MH<inline-formula><mml:math id="M320" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M321" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M322" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (CH<inline-formula><mml:math id="M323" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>CCH<inline-formula><mml:math id="M324" display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M325" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">41</mml:mn></mml:mrow></mml:math></inline-formula> Th) and [MH<inline-formula><mml:math id="M326" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M327" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M328" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M329" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (CH<inline-formula><mml:math id="M330" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>CO<inline-formula><mml:math id="M331" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, <inline-formula><mml:math id="M332" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">43</mml:mn></mml:mrow></mml:math></inline-formula> Th) for acetone had substantial decreases when BSQ amplitude was higher than 200 V (Figs. S9c and S10). The protonated ion MH<inline-formula><mml:math id="M333" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (CH<inline-formula><mml:math id="M334" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>COCH<inline-formula><mml:math id="M335" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M336" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, <inline-formula><mml:math id="M337" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">59</mml:mn></mml:mrow></mml:math></inline-formula> Th) and adduct ion (CH<inline-formula><mml:math id="M338" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>COCH<inline-formula><mml:math id="M339" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M340" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M341" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, <inline-formula><mml:math id="M342" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">77</mml:mn></mml:mrow></mml:math></inline-formula> Th), however, remained less unaffected. This effect leads to noticeable changes in the signal fractions of MH<inline-formula><mml:math id="M343" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (maximum 0.4) for small analytes such as ketones, unsaturated aldehydes, nitriles, and methanol (Figs. 3f and S14f) as the BSQ amplitude changes from 100 to 300 V.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Sensitivity and transmission of protonated ions</title>
      <p id="d1e4257">We calculated the sensitivity and transmission of the protonated ions (MH<inline-formula><mml:math id="M344" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> for the 21 VOCs studied when the instrument was under the optimized conditions. Table 1 shows the sensitivities (cps ppbv<inline-formula><mml:math id="M345" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> as slopes of MH<inline-formula><mml:math id="M346" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> signals vs. mixing ratios (average value from 0 to 22 ppbv under dry conditions, except for <inline-formula><mml:math id="M347" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene to 2 ppbv) and the limit of detection (LOD, 3<inline-formula><mml:math id="M348" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Panels a and b in Fig. 4 show the sensitivity vs. <inline-formula><mml:math id="M349" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for all 21 VOCs, while panels c and d show the transmission efficiencies calculated from the division of the sensitivity vs. <inline-formula><mml:math id="M350" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> ratio for each VOC by the slope fitted in Fig. 4a and b.</p>
      <p id="d1e4336">Except for formaldehyde (A2-1) and methanol (C2-1), whose MH<inline-formula><mml:math id="M351" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions have <inline-formula><mml:math id="M352" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values much lower than 60 Th, and <inline-formula><mml:math id="M353" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene (A2-3), which came with a very low concentration range, most VOCs had sensitivities above 1000 cps ppbv<inline-formula><mml:math id="M354" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. In addition to its low <inline-formula><mml:math id="M355" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values that limit the transmission, the backward reaction is also an important reason for the low sensitivity. For instance, formaldehyde has a low PA value (712.5 kJ mol<inline-formula><mml:math id="M356" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> that is not much higher than that of water (691.0 kJ mol<inline-formula><mml:math id="M357" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and has been shown to have a high tendency of backward reaction of Reaction (R1) (Inomata et al., 2008; Vlasenko et al., 2010; Warneke et al., 2011). The two compounds in group B5 (aromatic aldehydes), benzaldehyde and <inline-formula><mml:math id="M358" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-tolualdehyde, had the highest sensitivities of <inline-formula><mml:math id="M359" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 12 000 cps ppbv<inline-formula><mml:math id="M360" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. This might be due to their high PA values (<inline-formula><mml:math id="M361" display="inline"><mml:mo lspace="0mm">&gt;</mml:mo></mml:math></inline-formula> 830 kJ mol<inline-formula><mml:math id="M362" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, which are among the highest except for those of terpenoids (Table S2).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e4474">Sensitivity (slope), intercept, and limit of detection (LOD) based on 3 standard deviations (<inline-formula><mml:math id="M363" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and cylinder numbers (no.). Results were obtained from measurements of 0–22 ppbv for all VOCs except for <inline-formula><mml:math id="M364" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene (up to <inline-formula><mml:math id="M365" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 2 ppbv). The cylinder numbers for the VOCs studied are also shown here.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Cylinder</oasis:entry>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5">Sensitivity</oasis:entry>
         <oasis:entry colname="col6">3<inline-formula><mml:math id="M370" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> LOD</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Group<inline-formula><mml:math id="M371" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Name</oasis:entry>
         <oasis:entry colname="col3">no.</oasis:entry>
         <oasis:entry colname="col4">Label</oasis:entry>
         <oasis:entry colname="col5">(cps ppbv<inline-formula><mml:math id="M372" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">(pptv), 5 s</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">A1</oasis:entry>
         <oasis:entry colname="col2">Benzene</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">A1-1</oasis:entry>
         <oasis:entry colname="col5">2596</oasis:entry>
         <oasis:entry colname="col6">35</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Toluene</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">A1-2</oasis:entry>
         <oasis:entry colname="col5">5724</oasis:entry>
         <oasis:entry colname="col6">2</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">m-Xylene</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">A1-3</oasis:entry>
         <oasis:entry colname="col5">8669</oasis:entry>
         <oasis:entry colname="col6">3</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">1,2,4-Trimethylbenzene</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">A1-4</oasis:entry>
         <oasis:entry colname="col5">8951</oasis:entry>
         <oasis:entry colname="col6">1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">A2</oasis:entry>
         <oasis:entry colname="col2">Isoprene</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">A2-1</oasis:entry>
         <oasis:entry colname="col5">2140</oasis:entry>
         <oasis:entry colname="col6">16</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M373" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-Pinene</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">A2-2</oasis:entry>
         <oasis:entry colname="col5">4046</oasis:entry>
         <oasis:entry colname="col6">2</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M374" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-Caryophyllene</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">A2-3</oasis:entry>
         <oasis:entry colname="col5">723</oasis:entry>
         <oasis:entry colname="col6">1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">B1</oasis:entry>
         <oasis:entry colname="col2">Formaldehyde</oasis:entry>
         <oasis:entry colname="col3">II</oasis:entry>
         <oasis:entry colname="col4">B1-1</oasis:entry>
         <oasis:entry colname="col5">– <inline-formula><mml:math id="M375" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">– <inline-formula><mml:math id="M376" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Acetaldehyde</oasis:entry>
         <oasis:entry colname="col3">I&amp;II</oasis:entry>
         <oasis:entry colname="col4">B1-2</oasis:entry>
         <oasis:entry colname="col5">2096<inline-formula><mml:math id="M377" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">283</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">B2</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M378" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-Butanal</oasis:entry>
         <oasis:entry colname="col3">II</oasis:entry>
         <oasis:entry colname="col4">B2-1</oasis:entry>
         <oasis:entry colname="col5">1114</oasis:entry>
         <oasis:entry colname="col6">343</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Pentanal</oasis:entry>
         <oasis:entry colname="col3">II</oasis:entry>
         <oasis:entry colname="col4">B2-2</oasis:entry>
         <oasis:entry colname="col5">1465</oasis:entry>
         <oasis:entry colname="col6">63</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Hexaldehyde</oasis:entry>
         <oasis:entry colname="col3">II</oasis:entry>
         <oasis:entry colname="col4">B2-3</oasis:entry>
         <oasis:entry colname="col5">1595</oasis:entry>
         <oasis:entry colname="col6">35</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">B3</oasis:entry>
         <oasis:entry colname="col2">Acetone</oasis:entry>
         <oasis:entry colname="col3">I&amp;II</oasis:entry>
         <oasis:entry colname="col4">B3-1</oasis:entry>
         <oasis:entry colname="col5">9932<inline-formula><mml:math id="M379" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">127</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Methyl ethyl ketone</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">B3-3</oasis:entry>
         <oasis:entry colname="col5">9636</oasis:entry>
         <oasis:entry colname="col6">51</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">B4</oasis:entry>
         <oasis:entry colname="col2">Acrolein</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">B4-1</oasis:entry>
         <oasis:entry colname="col5">7224</oasis:entry>
         <oasis:entry colname="col6">16</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Methacrolein</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">B4-2</oasis:entry>
         <oasis:entry colname="col5">6090</oasis:entry>
         <oasis:entry colname="col6">13</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">B5</oasis:entry>
         <oasis:entry colname="col2">Benzaldehyde</oasis:entry>
         <oasis:entry colname="col3">II</oasis:entry>
         <oasis:entry colname="col4">B5-1</oasis:entry>
         <oasis:entry colname="col5">16 089</oasis:entry>
         <oasis:entry colname="col6">1</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M380" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>-Tolualdehyde</oasis:entry>
         <oasis:entry colname="col3">II</oasis:entry>
         <oasis:entry colname="col4">B5-2</oasis:entry>
         <oasis:entry colname="col5">12 893</oasis:entry>
         <oasis:entry colname="col6">1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">C1</oasis:entry>
         <oasis:entry colname="col2">Acetonitrile</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">C1-1</oasis:entry>
         <oasis:entry colname="col5">1511</oasis:entry>
         <oasis:entry colname="col6">6</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Acrylonitrile</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">C1-2</oasis:entry>
         <oasis:entry colname="col5">9275</oasis:entry>
         <oasis:entry colname="col6">1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">C2</oasis:entry>
         <oasis:entry colname="col2">Methanol</oasis:entry>
         <oasis:entry colname="col3">I</oasis:entry>
         <oasis:entry colname="col4">C2-1</oasis:entry>
         <oasis:entry colname="col5">–<inline-formula><mml:math id="M381" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">–<inline-formula><mml:math id="M382" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e4501">
<inline-formula><mml:math id="M366" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula> A1: aromatic hydrocarbons, A2: terpenoids, B1: small aldehydes; B2: long-chain aldehydes, B3: ketones, B4: unsaturated aldehydes, B5: aromatic aldehydes, C1: nitriles, C2: methanol. <inline-formula><mml:math id="M367" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula> The average value from gas cylinders I and II, with a deviation of less than <inline-formula><mml:math id="M368" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn></mml:mrow></mml:math></inline-formula> %.; <inline-formula><mml:math id="M369" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula> low sensitivity and high LOD due to low transmission.</p></table-wrap-foot><?xmltex \gdef\@currentlabel{1}?></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e5163">Sensitivity as a function of <inline-formula><mml:math id="M383" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for <bold>(a)</bold> MH<inline-formula><mml:math id="M384" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> and <bold>(b)</bold> all ions. Linear fitting was performed only for MH<inline-formula><mml:math id="M385" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> sensitivity. Species included in the fitting were those with <inline-formula><mml:math id="M386" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> value <inline-formula><mml:math id="M387" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 60 Th (Table S2) and signal percentage of MH<inline-formula><mml:math id="M388" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (<inline-formula><mml:math id="M389" display="inline"><mml:mrow><mml:msubsup><mml:mi>f</mml:mi><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msubsup><mml:mo>)</mml:mo><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">75</mml:mn></mml:mrow></mml:math></inline-formula> % (Table 1). The grey-shaded area is bounded by 0.5 <inline-formula><mml:math id="M390" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> slope 2 <inline-formula><mml:math id="M391" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> slope. The fitted curve in panel <bold>(b)</bold> is the same as in panel <bold>(a)</bold> and is for reference only. Panels <bold>(c)</bold> and <bold>(d)</bold> are transmission curves from MH<inline-formula><mml:math id="M392" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> only and from the sum of all ions, respectively. The sigmoidal curve for MH<inline-formula><mml:math id="M393" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (same for <bold>c</bold> and <bold>d</bold>) was fitted from species except for <inline-formula><mml:math id="M394" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene, <inline-formula><mml:math id="M395" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-pinene, <inline-formula><mml:math id="M396" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-butanal, pentanal, and hexaldehyde, whose fragmentation was significant. Note that only the <inline-formula><mml:math id="M397" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values of MH<inline-formula><mml:math id="M398" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> were used on the <inline-formula><mml:math id="M399" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axes of panel <bold>(c)</bold> and <bold>(d)</bold>, although panel <bold>(d)</bold> contains information for adduct and fragmented ions that have <inline-formula><mml:math id="M400" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values different from that of MH<inline-formula><mml:math id="M401" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, which does not consider the differences in <inline-formula><mml:math id="M402" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values of adduct and fragmented ions.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024-f04.png"/>

        </fig>

      <?pagebreak page2422?><p id="d1e5400">It was shown that the sensitivities for different VOCs in PTR-MS can be calculated from the kinetics of the proton-transfer reactions (Warneke et al., 2003; Sekimoto et al., 2017; Cappellin et al., 2012). For Vocus, Krechmer et al. (2018) also pointed out that the relationship between sensitivity and <inline-formula><mml:math id="M403" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> can be established and used to calculate the sensitivity for other compounds. We herein compare the relationship between sensitivity and <inline-formula><mml:math id="M404" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. 4a). In our data, the uncertainties for sensitivity were conservatively taken as the maximum percentage uncertainty (5.3 %) of fitted slopes. Values of <inline-formula><mml:math id="M405" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> were calculated as averages of both modeled and experimental results found in the literature (Table S3), with uncertainties propagated from an estimated percentage error of 15 % for both modeled  (Zhao and Zhang, 2004) and experimental values. The anticipated linear relationship of sensitivity vs. <inline-formula><mml:math id="M406" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is not easily visible, most likely due to the formation of fragments/adducts for some VOCs and low transmission efficiencies for others. However, a relatively improved linear relationship was found if we limit the VOCs to <inline-formula><mml:math id="M407" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values for MH<inline-formula><mml:math id="M408" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">60</mml:mn></mml:mrow></mml:math></inline-formula> Th and a fraction of MH<inline-formula><mml:math id="M409" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion in all ions (including adduct/fragmented ions) larger than 75 % (cf. Fig. 2). With these limitations, the fitted linear line gives a slope of (<inline-formula><mml:math id="M410" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.8</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.3</mml:mn></mml:mrow></mml:math></inline-formula>) <inline-formula><mml:math id="M411" display="inline"><mml:mrow><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">12</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> cps ppbv<inline-formula><mml:math id="M412" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> molec s cm<inline-formula><mml:math id="M413" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, approximately 38 % lower than that [(<inline-formula><mml:math id="M414" display="inline"><mml:mrow><mml:mn mathvariant="normal">4.5</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.4</mml:mn></mml:mrow></mml:math></inline-formula>) <inline-formula><mml:math id="M415" display="inline"><mml:mrow><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">12</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> cps ppbv<inline-formula><mml:math id="M416" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> molec s cm<inline-formula><mml:math id="M417" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>] of Krechmer et al. (2018). Pearson's <inline-formula><mml:math id="M418" display="inline"><mml:mi>R</mml:mi></mml:math></inline-formula> (<inline-formula><mml:math id="M419" display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mi mathvariant="normal">Pr</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is 0.77. A grey area is also shown by two lines of 2 <inline-formula><mml:math id="M420" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> slope and 0.5 <inline-formula><mml:math id="M421" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> slope, which includes approximately half (10) of the VOCs studied. Those that fall outside of the grey area and into the lower region are mainly compounds in groups B2 (long-chain aldehydes, purple), C1 and C2 (nitriles or methanol, black), B1 (small aldehydes, red), and A2 (terpenoids, green). Using the total signals of all ions (protonated, adduct, and fragmented), Fig. 4b shows the improvements for compounds in group B2 only, while others (especially those in C1, C2, and B1) do not move up to the grey area.</p>
      <p id="d1e5617">We also calculated the transmission efficiencies (Fig. 4c and d) from the division of the sensitivity vs. <inline-formula><mml:math id="M422" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> ratio for each VOC by the slope fitted in Fig. 4a. It is shown that compounds in groups B1, C1, and C2 are mainly on the rising range of the sigmoidal curve, while the three long-chain aldehydes in group B2 (purple) are well below the curve if only MH<inline-formula><mml:math id="M423" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions were used; these three long-chain aldehydes move up to transmission <inline-formula><mml:math id="M424" display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula> when all ions are considered (Fig. 4d). Of particular interest is the compound <inline-formula><mml:math id="M425" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-pinene, whose transmission was <inline-formula><mml:math id="M426" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 0.5 when only the MH<inline-formula><mml:math id="M427" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion was used but increases to about 1.5 when the fragmented ion was considered. Note that in Fig. 4d, the <inline-formula><mml:math id="M428" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> value of MH<inline-formula><mml:math id="M429" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> was used for the <inline-formula><mml:math id="M430" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> axis for the summed ion signals, which might lead to certain bias as the fragmented and adduct ions have different <inline-formula><mml:math id="M431" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> values. Nevertheless, the above analysis suggests that both the formation  and transmission of adduct/fragmented ions affect the relationship between sensitivity and <inline-formula><mml:math id="M432" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, requiring precaution when using predicted sensitivity directly from <inline-formula><mml:math id="M433" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. In addition, one needs to be cautious regarding the prediction of transmission efficiency with <inline-formula><mml:math id="M434" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>Q</mml:mi></mml:mrow></mml:math></inline-formula> greater than 150.</p>
</sec>
<?pagebreak page2423?><sec id="Ch1.S3.SS3">
  <label>3.3</label><title>RH dependence of ion signals</title>
      <p id="d1e5757">One of the most important causes of RH dependence is that the distribution of reagent ions might vary with ambient RH, especially when the abundance of H<inline-formula><mml:math id="M435" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M436" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> in the PTR reactor is not high. While the Vocus has been shown to have abundant H<inline-formula><mml:math id="M437" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M438" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>  (Krechmer et al., 2018), whether it can substantially minimize RH dependence for most VOCs deserves scrutiny. Figure 5a–h show the relative sensitivity defined as the relative change in sensitivity of MH<inline-formula><mml:math id="M439" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion vs. VOC concentration under different RH conditions. Among the nine groups of VOCs studied, seven groups show almost flat relative sensitivities within the RH range of <inline-formula><mml:math id="M440" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 % to <inline-formula><mml:math id="M441" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 % (298 K), with the exception of long-chain aldehydes (group B2) that show increasing sensitivities as RH increases (Fig. 5d) and methanol (group C2) showing large variations (Fig. 5h). Some other compounds, such as <inline-formula><mml:math id="M442" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-caryophyllene (A2-3, Fig. 5b) and formaldehyde (B1-1, Fig. 5c), also show either relatively large uncertainties or fluctuations, which can be ascribed to their low intensities (cf. Table 1).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e5829">The dependence of the MH<inline-formula><mml:math id="M443" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> signals on RH for the VOCs studied. Panels <bold>(a)</bold>–<bold>(h)</bold> illustrate the relative sensitivity calculated as the slope (sensitivity) under all conditions compared to that under the dry (RH <inline-formula><mml:math id="M444" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 5 %) condition. Panel <bold>(i)</bold> shows the percent change in relative sensitivity per 10 % RH increase. See Figs. S15–S17 for other ion signals.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024-f05.png"/>

        </fig>

      <p id="d1e5863">Figure 5i shows the RH dependence of the MH<inline-formula><mml:math id="M445" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions, defined as the percentage change in sensitivity per 10 % RH increase, for all 21 VOCs studied. Aromatic hydrocarbons (group A1) show negative RH dependence as in previous studies using PTR-MS with a drift tube (Warneke et al., 2001; Steinbacher et al., 2004). While previous studies reported decreases in benzene sensitivity by 16 %–56 % from dry to humid conditions (up to 100 % RH), our results show a decrease of less than 1.1 % per 10 % RH increase (i.e., <inline-formula><mml:math id="M446" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 11 % in the whole RH range) with a somewhat narrower RH range (up to <inline-formula><mml:math id="M447" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 % RH). In addition, two out of the three terpenoids (group A2) also show slightly negative RH dependence, and the other one (<inline-formula><mml:math id="M448" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-pinene) shows very small positive RH dependence (Fig. 5i). These hydrocarbons (aromatics and terpenoids) in groups A1 and A2 have relatively low <inline-formula><mml:math id="M449" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values (mostly <inline-formula><mml:math id="M450" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M451" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.5</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math id="M452" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> molec<inline-formula><mml:math id="M453" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> s<inline-formula><mml:math id="M454" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, Table S3), and their RH dependence shows a fairly strong correlation with the PA value (Fig. 6a, purple circles and squares). This observation suggests that there might be a thermodynamic reason behind the noticeable decrease in sensitivity for hydrocarbons such as benzene as RH increases. Since hydrocarbons such as benzene and toluene do not readily react with H<inline-formula><mml:math id="M455" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M456" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>(H<inline-formula><mml:math id="M457" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O) (Warneke et al., 2001), Reaction (R1) is the main reaction required to form MH<inline-formula><mml:math id="M458" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>. As water vapor concentration increases at high RH, the reverse reaction of Reaction (R1) might be important for compounds with low PA and low <inline-formula><mml:math id="M459" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values (Inomata et al., 2008).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e6017">The RH dependence of the MH<inline-formula><mml:math id="M460" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion plotted against PA, color-coded by <bold>(a)</bold> <inline-formula><mml:math id="M461" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <bold>(b)</bold> <inline-formula><mml:math id="M462" display="inline"><mml:mrow><mml:msubsup><mml:mi>f</mml:mi><mml:mi mathvariant="normal">MH</mml:mi><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/17/2415/2024/amt-17-2415-2024-f06.png"/>

        </fig>

      <?pagebreak page2424?><p id="d1e6065">Long-chain aldehydes (group B2) have the largest RH dependence of 1 %–4 % positive deviation per 10 % RH increase for the MH<inline-formula><mml:math id="M463" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions. The RH dependence of the [MH<inline-formula><mml:math id="M464" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M465" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M466" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions (Fig. S15g) is much higher (1.4 %–8.5 % positive deviation per 10 % RH increase). Interestingly, the trends of RH dependence for the MH<inline-formula><mml:math id="M467" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions and that for the [MH<inline-formula><mml:math id="M468" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M469" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M470" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions for long-chain aldehydes are exactly opposite (Figs. 5i and S15g); i.e., pentanal <inline-formula><mml:math id="M471" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M472" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-butanal <inline-formula><mml:math id="M473" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> hexaldehyde. The reason behind this observation is out of the scope of this study. The dominating [MH<inline-formula><mml:math id="M474" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M475" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M476" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions for long-chain aldehydes (Fig. 2), however, show much less (<inline-formula><mml:math id="M477" display="inline"><mml:mo lspace="0mm">±</mml:mo></mml:math></inline-formula> 1 % per 10 % RH increase) RH dependence (Fig. S16i). Other carbonyl compounds (groups B1, B3, B4, and B5) also show positive deviations as RH increases (less than 1.5 % increase in sensitivity per 10 % RH increase), albeit to various degrees (Fig. 5i). Similarly to long-chain aldehydes, the [MH<inline-formula><mml:math id="M478" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M479" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M480" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions also show a large positive deviation (Fig. S16g), and [MH<inline-formula><mml:math id="M481" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M482" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M483" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions show little RH dependence (Fig. S16e). These carbonyl compounds (except formaldehyde) have medium PA values (Fig. 6a). If we exclude formaldehyde (with an extremely low PA value, the upward-pointing triangle to the far left in Fig. 6b) and long-chain aldehydes (low percentages of MH<inline-formula><mml:math id="M484" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions, <inline-formula><mml:math id="M485" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 25 %, downward-pointing triangles in Fig. 6b), the RH dependence of other carbonyl compounds shows a slightly decreasing trend of RH dependence vs. PA values (Fig. 6b, upward-pointing triangles, left-pointing triangles, right-pointing triangles, and double triangles). These observations might hint at the relationships between the RH dependence of carbonyl compounds and reagent ion distribution as well as the reaction direction for Reactions (R1)–(R4), which is different from those for pure hydrocarbons (groups A1 and A2). Finally, the RH dependence of MH<inline-formula><mml:math id="M486" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> for compounds in groups C1 (nitriles) and C2 (methanol) is within <inline-formula><mml:math id="M487" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>1 % per 10 % RH increase (Fig. 5i).</p>
      <p id="d1e6275">Overall, in the whole RH range studied (<inline-formula><mml:math id="M488" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 5 % to <inline-formula><mml:math id="M489" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 %), the RH dependence of MH<inline-formula><mml:math id="M490" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions for the 21 VOCs studied is less than 30 %, with most compounds (except group B2, long-chain aldehydes) less than 15 %. For [MH<inline-formula><mml:math id="M491" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M492" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M493" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions (mainly for carbonyl compounds), strong RH dependence was observed (Fig. S15) at 1.4 %–8.5 % per 10 % RH increase or 8.9 %–63.2 % from <inline-formula><mml:math id="M494" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 % to <inline-formula><mml:math id="M495" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 % RH. The dehydrated ions ([MH<inline-formula><mml:math id="M496" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M497" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M498" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, however, show the smallest RH dependence (<inline-formula><mml:math id="M499" display="inline"><mml:mo lspace="0mm">±</mml:mo></mml:math></inline-formula> 1 % per 10 % RH increase) among all the ions (Fig. S16). Fragmented ions with decarbonization ([MH<inline-formula><mml:math id="M500" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>C<inline-formula><mml:math id="M501" display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>H<inline-formula><mml:math id="M502" display="inline"><mml:msub><mml:mi/><mml:mi>y</mml:mi></mml:msub></mml:math></inline-formula>]<inline-formula><mml:math id="M503" display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> show a mainly negative RH dependence of generally less than 3 % per 10 % RH increase (Fig. S17).</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e6423">We investigated the response of protonated, adduct, and fragmented ions of 21 atmospherically relevant VOCs in a Vocus PTR-MS as instrument settings and RH conditions vary. For the two ways of increasing the <inline-formula><mml:math id="M504" display="inline"><mml:mrow><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula> ratio, increasing the FIMR axial voltage can substantially (by 3 to 4 orders of magnitude) increase sensitivity but does not change the fractions of the MH<inline-formula><mml:math id="M505" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions (mostly within 30 %); reducing the FIMR pressure, however, does not enhance sensitivity much but can lead to more substantial fragmentation. Therefore, a high FIMR axial voltage of 600–700 V and a medium pressure of around 2.0 mbar are recommended. Increasing the RF amplitude of the FIMR can increase sensitivity by 1 to 1.5 orders of magnitude at 2.0 mbar and 1.5 to 2 orders of magnitude at 3.5 mbar, and it does not change the MH<inline-formula><mml:math id="M506" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion fractions (within 20 %). Therefore, a high RF amplitude of 500 V is recommended. Increasing the BSQ amplitude does not increase the sensitivity much but changes the MH<inline-formula><mml:math id="M507" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion fractions of small ions substantially by changing the transmission efficiency. The choice of this instrument setting mainly relies on which ions (i.e., those reagent ions with an abundance that is too high) one wishes to filter out. Our selected setting is 300 V, which gives a 50 % transmission at about 55 Th.</p>
      <p id="d1e6465">The relationship between sensitivity and <inline-formula><mml:math id="M508" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is strongly affected by two factors, including whether the MH<inline-formula><mml:math id="M509" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion has a high transmission efficiency and whether the MH<inline-formula><mml:math id="M510" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ion is the dominating ion. When both conditions are met, a fairly strong correlation (<inline-formula><mml:math id="M511" display="inline"><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mi mathvariant="normal">Pr</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.77</mml:mn></mml:mrow></mml:math></inline-formula>) was observed for the VOCs studied. The transmission curve also more reasonably resembles the sigmoid function only if all the ions (protonated, adduct, and fragmented) are considered. The low transmission efficiencies of formaldehyde and methanol result in extremely low sensitivities of these two small OVOCs, although a low PA value is another reason for the former.</p>
      <p id="d1e6512">As RH increases from <inline-formula><mml:math id="M512" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 % to <inline-formula><mml:math id="M513" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 85 %, the MH<inline-formula><mml:math id="M514" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions for 19 out of the 21 VOCs studied have sensitivity variation of less than 15 %, but long-chain aldehydes have a positive RH dependence of up to 30 %. The RH dependence of [MH<inline-formula><mml:math id="M515" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M516" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M517" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions for long-chain aldehydes is stronger, while that of the dominating [MH<inline-formula><mml:math id="M518" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>H<inline-formula><mml:math id="M519" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O]<inline-formula><mml:math id="M520" display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> ions is limited. Therefore, the signal distributions among protonated, adduct, and fragmented ions are also affected by RH variation. Together with their relatively high background signals (especially for <inline-formula><mml:math id="M521" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-butanal, Fig. S5b), quantification of long-chain aldehydes in the ambient environment using Vocus requires special attention. It is also worth noting that hydrocarbons generally show a slightly negative RH dependence, probably due to their relatively low <inline-formula><mml:math id="M522" display="inline"><mml:mrow><mml:msub><mml:mi>k</mml:mi><mml:mi mathvariant="normal">ptr</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values, although such RH dependence does not affect quantification significantly; their RH dependence shares a fairly strong correlation with their PA values, hinting at a thermodynamic reason behind this trend.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e6612">The time series of RH experiments and the instrument setting experiment are freely available: <uri>https://zenodo.org/records/10947779</uri> (Li et al., 2024).</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e6618">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-17-2415-2024-supplement" xlink:title="pdf">https://doi.org/10.5194/amt-17-2415-2024-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e6627">YJL and FL conceived the ideas and designed the methodology. FL conducted the experiments. YJL and FL analyzed the data and drafted the manuscript. DDH, LT, BY, WT, LZ, PY, DW, KIH, and KMM provided significant input during the revision of the manuscript. YJL and KMM acquired financial support for the project. All authors contributed critically to the drafts and gave final approval for publication.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e6633">At least one of the (co-)authors is a member of the editorial board of <italic>Atmospheric Measurement Techniques</italic>. The peer-review process was guided by an independent editor, and the authors also have no other competing interests to declare.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e6642">Publisher’s note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e6648">This work was supported by funding support from the Science and Technology Development Fund, Macau SAR (file no. FDCT 0031/2023/AFJ), and a multiyear research grant (no. MYRG2022-00027-FST) from the University of Macau.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e6653">This research has been supported by the Fundo para o Desenvolvimento das Ciências e da Tecnologia (grant no. FDCT 0031/2023/AFJ) and the Universidade de Macau (grant no. MYRG2022-00027-FST).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e6659">This paper was edited by Hendrik Fuchs and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><?label 1?><mixed-citation>Baasandorj, M., Millet, D. B., Hu, L., Mitroo, D., and Williams, B. J.: Measuring acetic and formic acid by proton-transfer-reaction mass spectrometry: sensitivity, humidity dependence, and quantifying interferences, Atmos. Meas. Tech., 8, 1303–1321, <ext-link xlink:href="https://doi.org/10.5194/amt-8-1303-2015" ext-link-type="DOI">10.5194/amt-8-1303-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><?label 1?><mixed-citation>Cappellin, L., Karl, T., Probst, M., Ismailova, O., Winkler, P. M., Soukoulis, C., Aprea, E., Märk, T. D., Gasperi, F., and Biasioli, F.: On Quantitative Determination of Volatile Organic Compound Concentrations Using Proton Transfer Reaction Time-of-Flight Mass Spectrometry, Environ. Sci. Technol., 46, 2283–2290, <ext-link xlink:href="https://doi.org/10.1021/es203985t" ext-link-type="DOI">10.1021/es203985t</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><?label 1?><mixed-citation>Claflin, M. S., Pagonis, D., Finewax, Z., Handschy, A. V., Day, D. A., Brown, W. L., Jayne, J. T., Worsnop, D. R., Jimenez, J. L., Ziemann, P. J., de Gouw, J., and Lerner, B. M.: An in situ gas chromatograph with automatic detector switching between PTR- and EI-TOF-MS: isomer-resolved measurements of indoor air, Atmos. Meas. Tech., 14, 133–152, <ext-link xlink:href="https://doi.org/10.5194/amt-14-133-2021" ext-link-type="DOI">10.5194/amt-14-133-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><?label 1?><mixed-citation>Cui, L., Zhang, Z., Huang, Y., Lee, S. C., Blake, D. R., Ho, K. F., Wang, B., Gao, Y., Wang, X. M., and Louie, P. K. K.: Measuring OVOCs and VOCs by PTR-MS in an urban roadside microenvironment of Hong Kong: relative humidity and temperature dependence, and field intercomparisons, Atmos. Meas. Tech., 9, 5763–5779, <ext-link xlink:href="https://doi.org/10.5194/amt-9-5763-2016" ext-link-type="DOI">10.5194/amt-9-5763-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><?label 1?><mixed-citation>de Gouw, J. and Warneke, C.: Measurements of volatile organic compounds in the earths atmosphere using proton-transfer-reaction mass spectrometry, Mass Spectrom. Rev., 26, 223–257, <ext-link xlink:href="https://doi.org/10.1002/mas.20119" ext-link-type="DOI">10.1002/mas.20119</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><?label 1?><mixed-citation>de Gouw, J. A., Goldan, P. D., Warneke, C., Kuster, W. C., Roberts, J. M., Marchewka, M., Bertman, S. B., Pszenny, A. A. P., and Keene, W. C.: Validation of proton transfer reaction-mass spectrometry (PTR-MS) measurements of gas-phase organic compounds in the atmosphere during the New England Air Quality Study (NEAQS) in 2002, J. Geophys. Res.-Atmos., 108, 4682,  <ext-link xlink:href="https://doi.org/10.1029/2003JD003863" ext-link-type="DOI">10.1029/2003JD003863</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><?label 1?><mixed-citation>Ellis, A. M. and Mayhew, C. A.: Chemical Ionization: Chemistry, Thermodynamics and Kinetics, in: Proton Transfer Reaction Mass Spectrometry, Wiley, 25–48, <ext-link xlink:href="https://doi.org/10.1002/9781118682883.ch2" ext-link-type="DOI">10.1002/9781118682883.ch2</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><?label 1?><mixed-citation>Gueneron, M., Erickson, M. H., VanderSchelden, G. S., and Jobson, B. T.: PTR-MS fragmentation patterns of gasoline hydrocarbons, Int. J. Mass Spectrom., 379, 97–109, <ext-link xlink:href="https://doi.org/10.1016/j.ijms.2015.01.001" ext-link-type="DOI">10.1016/j.ijms.2015.01.001</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><?label 1?><mixed-citation>Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., and Lindinger, W.: Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level, Int. J. Mass Spectrom. Ion Process., 149–150, 609–619, <ext-link xlink:href="https://doi.org/10.1016/0168-1176(95)04294-U" ext-link-type="DOI">10.1016/0168-1176(95)04294-U</ext-link>, 1995.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><?label 1?><mixed-citation>Hartungen, E. v., Wisthaler, A., Mikoviny, T., Jaksch, D., Boscaini, E., Dunphy, P. J., and Märk, T. D.: Proton-transfer-reaction mass spectrometry (PTR-MS) of carboxylic acids: Determination of Henry's law constants and axillary odour investigations, Int. J. Mass Spectrom., 239, 243–248, <ext-link xlink:href="https://doi.org/10.1016/j.ijms.2004.09.009" ext-link-type="DOI">10.1016/j.ijms.2004.09.009</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><?label 1?><mixed-citation>Inomata, S., Tanimoto, H., Kameyama, S., Tsunogai, U., Irie, H., Kanaya, Y., and Wang, Z.: Technical Note: Determination of formaldehyde mixing ratios in air with PTR-MS: laboratory experiments and field measurements, Atmos. Chem. Phys., 8, 273–284, <ext-link xlink:href="https://doi.org/10.5194/acp-8-273-2008" ext-link-type="DOI">10.5194/acp-8-273-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><?label 1?><mixed-citation>Jensen, A., Liu, Z., Tan, W., Dix, B., Chen, T., Koss, A., Zhu, L., Li, L., and de Gouw, J.: Measurements of Volatile Organic Compounds During the COVID-19 Lockdown in Changzhou, China, Geophys. Res. Lett., 48, e2021GL095560, <ext-link xlink:href="https://doi.org/10.1029/2021GL095560" ext-link-type="DOI">10.1029/2021GL095560</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><?label 1?><mixed-citation>Kari, E., Miettinen, P., Yli-Pirilä, P., Virtanen, A., and Faiola, C. L.: PTR-ToF-MS product ion distributions and humidity-dependence of biogenic volatile organic compounds, Int. J. Mass Spectrom., 430, 87–97, <ext-link xlink:href="https://doi.org/10.1016/j.ijms.2018.05.003" ext-link-type="DOI">10.1016/j.ijms.2018.05.003</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><?label 1?><mixed-citation>Krechmer, J., Lopez-Hilfiker, F., Koss, A., Hutterli, M., Stoermer, C., Deming, B., Kimmel, J., Warneke, C., Holzinger, R., Jayne, J., Worsnop, D., Fuhrer, K., Gonin, M., and de Gouw, J.: Evaluation of a New Reagent-Ion Source and Focusing Ion–Molecule Reactor for Use in Proton-Transfer-Reaction Mass Spectrometry, Anal. Chem., 90, 12011–12018, <ext-link xlink:href="https://doi.org/10.1021/acs.analchem.8b02641" ext-link-type="DOI">10.1021/acs.analchem.8b02641</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><?label 1?><mixed-citation>Li, F., Huang, D. D., Tian, L., Bin, Y., Wen, T., Zhu, L., Ye, P., Worsnop, D., Hoi, K. I., Mok, K. M., and Li, Y. J.: Response of protonated, adduct, and fragmented ions in Vocus proton-transfer-reaction time-of-flight mass (PTR-ToF-MS) spectrometer, Zenodo [data set], <uri>https://zenodo.org/records/10947779</uri>​​​​​​​ (last access: 23 April 2024), 2024.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><?label 1?><mixed-citation>Li, H., Almeida, T. G., Luo, Y., Zhao, J., Palm, B. B., Daub, C. D., Huang, W., Mohr, C., Krechmer, J. E., Kurtén, T., and Ehn, M.: Fragmentation insid<?pagebreak page2426?>e proton-transfer-reaction-based mass spectrometers limits the detection of ROOR and ROOH peroxides, Atmos. Meas. Tech., 15, 1811–1827, <ext-link xlink:href="https://doi.org/10.5194/amt-15-1811-2022" ext-link-type="DOI">10.5194/amt-15-1811-2022</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><?label 1?><mixed-citation>Lindinger, W., Hansel, A., and Jordan, A.: On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research, Int. J. Mass Spectrom. Ion Process., 173, 191–241, <ext-link xlink:href="https://doi.org/10.1016/S0168-1176(97)00281-4" ext-link-type="DOI">10.1016/S0168-1176(97)00281-4</ext-link>, 1998.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><?label 1?><mixed-citation>Materić, D., Lanza, M., Sulzer, P., Herbig, J., Bruhn, D., Gauci, V., Mason, N., and and Turner, C.: Selective reagent ion-time of flight-mass spectrometry study of six common monoterpenes, Int. J. Mass Spectrom., 421, 40–50, <ext-link xlink:href="https://doi.org/10.1016/j.ijms.2017.06.003" ext-link-type="DOI">10.1016/j.ijms.2017.06.003</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><?label 1?><mixed-citation>Michoud, V., Sauvage, S., Léonardis, T., Fronval, I., Kukui, A., Locoge, N., and Dusanter, S.: Field measurements of methylglyoxal using proton transfer reaction time-of-flight mass spectrometry and comparison to the DNPH–HPLC–UV method, Atmos. Meas. Tech., 11, 5729–5740, <ext-link xlink:href="https://doi.org/10.5194/amt-11-5729-2018" ext-link-type="DOI">10.5194/amt-11-5729-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><?label 1?><mixed-citation>Pagonis, D., Sekimoto, K., and de Gouw, J.: A Library of Proton-Transfer Reactions of H<inline-formula><mml:math id="M523" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M524" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> Ions Used for Trace Gas Detection, J. Am. Soc. Mass. Spectr., 30, 1330–1335, <ext-link xlink:href="https://doi.org/10.1007/s13361-019-02209-3" ext-link-type="DOI">10.1007/s13361-019-02209-3</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><?label 1?><mixed-citation>Pleil, J. D., Hansel, A., and Beauchamp, J.: Advances in proton transfer reaction mass spectrometry (PTR-MS): applications in exhaled breath analysis, food science, and atmospheric chemistry, J. Breath Res., 13, 039002, <ext-link xlink:href="https://doi.org/10.1088/1752-7163/ab21a7" ext-link-type="DOI">10.1088/1752-7163/ab21a7</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><?label 1?><mixed-citation>Salazar Gómez, J. I., Sojka, M., Klucken, C., Schlögl, R., and Ruland, H.: Determination of trace compounds and artifacts in nitrogen background measurements by proton transfer reaction time-of-flight  under dry and humid conditions, J. Mass. Spectrom., 56, e4777, <ext-link xlink:href="https://doi.org/10.1002/jms.4777" ext-link-type="DOI">10.1002/jms.4777</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><?label 1?><mixed-citation>Schripp, T., Etienne, S., Fauck, C., Fuhrmann, F., Märk, L., and Salthammer, T.: Application of proton-transfer-reaction-mass-spectrometry for Indoor Air Quality research, Indoor Air, 24, 178–189, <ext-link xlink:href="https://doi.org/10.1111/ina.12061" ext-link-type="DOI">10.1111/ina.12061</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><?label 1?><mixed-citation>Sekimoto, K., Li, S.-M., Yuan, B., Koss, A., Coggon, M., Warneke, C., and de Gouw, J.: Calculation of the sensitivity of proton-transfer-reaction mass spectrometry (PTR-MS) for organic trace gases using molecular properties, Int. J. Mass Spectrom., 421, 71–94, <ext-link xlink:href="https://doi.org/10.1016/j.ijms.2017.04.006" ext-link-type="DOI">10.1016/j.ijms.2017.04.006</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><?label 1?><mixed-citation>Sekimoto, K. and Koss, A. R.: Modern mass spectrometry in atmospheric sciences: Measurement of volatile organic compounds in the troposphere using proton-transfer-reaction mass spectrometry, J. Mass Spectrom., 56, <ext-link xlink:href="https://doi.org/10.1002/jms.4619" ext-link-type="DOI">10.1002/jms.4619</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><?label 1?><mixed-citation>Shao, P., An, J., Xin, J., Wu, F., Wang, J., Ji, D., and Wang, Y.: Source apportionment of VOCs and the contribution to photochemical ozone formation during summer in the typical industrial area in the Yangtze River Delta, China, Atmos. Res., 176–177, 64–74, <ext-link xlink:href="https://doi.org/10.1016/j.atmosres.2016.02.015" ext-link-type="DOI">10.1016/j.atmosres.2016.02.015</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><?label 1?><mixed-citation>Shrivastava, M., Cappa, C. D., Fan, J., Goldstein, A. H., Guenther, A. B., Jimenez, J. L., Kuang, C., Laskin, A., Martin, S. T., Ng, N. L., Petaja, T., Pierce, J. R., Rasch, P. J., Roldin, P., Seinfeld, J. H., Shilling, J., Smith, J. N., Thornton, J. A., Volkamer, R., Wang, J., Worsnop, D. R., Zaveri, R. A., Zelenyuk, A., and Zhang, Q.: Recent advances in understanding secondary organic aerosol: Implications for global climate forcing, Rev. Geophys., 55, 509–559, <ext-link xlink:href="https://doi.org/10.1002/2016RG000540" ext-link-type="DOI">10.1002/2016RG000540</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><?label 1?><mixed-citation>Sinha, V., Custer, T. G., Kluepfel, T., and Williams, J.: The effect of relative humidity on the detection of pyrrole by PTR-MS for OH reactivity measurements, Int. J. Mass Spectrom., 282, 108–111, <ext-link xlink:href="https://doi.org/10.1016/j.ijms.2009.02.019" ext-link-type="DOI">10.1016/j.ijms.2009.02.019</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><?label 1?><mixed-citation>Smith, D., Diskin, A., Ji, Y. F., and Spanel, P.: Concurrent use of H3O<inline-formula><mml:math id="M525" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>, NO<inline-formula><mml:math id="M526" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>, and O-2(<inline-formula><mml:math id="M527" display="inline"><mml:mrow><mml:mo>+</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> precursor ions for the detection and quantification of diverse trace gases in the presence of air and breath by selected ion-flow tube mass spectrometry, Int. J. Mass Spectrom., 209, 81–97, <ext-link xlink:href="https://doi.org/10.1016/S1387-3806(01)00478-X" ext-link-type="DOI">10.1016/S1387-3806(01)00478-X</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><?label 1?><mixed-citation>Ŝpaněl, P.  and Smith, D.: SIFT studies of the reactions of H<inline-formula><mml:math id="M528" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M529" display="inline"><mml:msub><mml:mi/><mml:mo>+</mml:mo></mml:msub></mml:math></inline-formula>, NO<inline-formula><mml:math id="M530" display="inline"><mml:msub><mml:mi/><mml:mo>+</mml:mo></mml:msub></mml:math></inline-formula> and O<inline-formula><mml:math id="M531" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msub></mml:math></inline-formula> with a series of volatile carboxylic acids and esters, Int. J. Mass Spectrom. Ion Process., 172, 137–147, <ext-link xlink:href="https://doi.org/10.1016/S0168-1176(97)00246-2" ext-link-type="DOI">10.1016/S0168-1176(97)00246-2</ext-link>, 1998.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><?label 1?><mixed-citation>Ŝpaněl, P. and Smith, D.: Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath, Med. Biol. Eng. Comput., 34, 409–419, <ext-link xlink:href="https://doi.org/10.1007/BF02523843" ext-link-type="DOI">10.1007/BF02523843</ext-link>, 1996.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><?label 1?><mixed-citation>Ŝpaněl, P., Ji, Y., and Smith, D.: SIFT studies of the reactions of H<inline-formula><mml:math id="M532" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M533" display="inline"><mml:msub><mml:mi/><mml:mo>+</mml:mo></mml:msub></mml:math></inline-formula>, NO<inline-formula><mml:math id="M534" display="inline"><mml:msub><mml:mi/><mml:mo>+</mml:mo></mml:msub></mml:math></inline-formula> and O<inline-formula><mml:math id="M535" display="inline"><mml:msub><mml:mi/><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:mrow></mml:msub></mml:math></inline-formula> with a series of aldehydes and ketones, Int. J. Mass Spectrom. Ion Process., 165–166, 25–37, <ext-link xlink:href="https://doi.org/10.1016/S0168-1176(97)00166-3" ext-link-type="DOI">10.1016/S0168-1176(97)00166-3</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><?label 1?><mixed-citation>Ŝpaněl, P.  and Smith, D.: Influence of water vapour on selected ion flow tube mass spectrometric analyses of trace gases in humid air and breath, Rapid Commun. Mass Spectrom., 14, 1898–1906, <ext-link xlink:href="https://doi.org/10.1002/1097-0231(20001030)14:20&lt;1898::AID-RCM110&gt;3.0.CO;2-G" ext-link-type="DOI">10.1002/1097-0231(20001030)14:20&lt;1898::AID-RCM110&gt;3.0.CO;2-G</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><?label 1?><mixed-citation>Steinbacher, M., Dommen, J., Ammann, C., Spirig, C., Neftel, A., and Prevot, A. S. H.: Performance characteristics of a proton-transfer-reaction mass spectrometer (PTR-MS) derived from laboratory and field measurements, Int. J. Mass Spectrom., 239, 117–128, <ext-link xlink:href="https://doi.org/10.1016/j.ijms.2004.07.015" ext-link-type="DOI">10.1016/j.ijms.2004.07.015</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><?label 1?><mixed-citation>Vlasenko, A., Macdonald, A. M., Sjostedt, S. J., and Abbatt, J. P. D.: Formaldehyde measurements by Proton transfer reaction – Mass Spectrometry (PTR-MS): correction for humidity effects, Atmos. Meas. Tech., 3, 1055–1062, <ext-link xlink:href="https://doi.org/10.5194/amt-3-1055-2010" ext-link-type="DOI">10.5194/amt-3-1055-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><?label 1?><mixed-citation>Wang, Y., Yang, G., Lu, Y., Liu, Y., Chen, J., and Wang, L.: Detection of gaseous dimethylamine using vocus proton-transfer-reaction time-of-flight mass spectrometry, Atmos. Environ., 243, 117875, <ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2020.117875" ext-link-type="DOI">10.1016/j.atmosenv.2020.117875</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><?label 1?><mixed-citation>Warneke, C., van der Veen, C., Luxembourg, S., de Gouw, J. A., and Kok, A.: Measurements of benzene and toluene in ambient air using proton-transfer-reaction mass spectrometry: calibration, humidity dependence, and field intercomparison, Int. J. Mass Spectrom., 207, 167–182, <ext-link xlink:href="https://doi.org/10.1016/S1387-3806(01)00366-9" ext-link-type="DOI">10.1016/S1387-3806(01)00366-9</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><?label 1?><mixed-citation>Warneke, C., De Gouw, J. A., Kuster, W. C., Goldan, P. D., and Fall, R.: Validation of atmospheric VOC measurements by proton-transfer-reaction mass spectrometry using a gas-chromatographic preseparation method, Environ. Sci. Technol., 37, 2494–2501, <ext-link xlink:href="https://doi.org/10.1021/es026266i" ext-link-type="DOI">10.1021/es026266i</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><?label 1?><mixed-citation>Warneke, C., Veres, P., Holloway, J. S., Stutz, J., Tsai, C., Alvarez, S., Rappenglueck, B., Fehsenfeld, F. C., Graus, M., Gilman, J. B., and de Gouw, J. A.: Airborne formaldehyd<?pagebreak page2427?>e measurements using PTR-MS: calibration, humidity dependence, inter-comparison and initial results, Atmos. Meas. Tech., 4, 2345–2358, <ext-link xlink:href="https://doi.org/10.5194/amt-4-2345-2011" ext-link-type="DOI">10.5194/amt-4-2345-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><?label 1?><mixed-citation>Yuan, B., Koss, A. R., Warneke, C., Coggon, M., Sekimoto, K., and de Gouw, J. A.: Proton-Transfer-Reaction Mass Spectrometry: Applications in Atmospheric Sciences, Chem. Rev., 117, 13187–13229, <ext-link xlink:href="https://doi.org/10.1021/acs.chemrev.7b00325" ext-link-type="DOI">10.1021/acs.chemrev.7b00325</ext-link>, 2017. </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib41"><label>41</label><?label 1?><mixed-citation>Zhao, J. and Zhang, R.: Proton transfer reaction rate constants between hydronium ion (H<inline-formula><mml:math id="M536" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math id="M537" display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula>) and volatile organic compounds, Atmos. Environ., 38, 2177–2185, <ext-link xlink:href="https://doi.org/10.1016/j.atmosenv.2004.01.019" ext-link-type="DOI">10.1016/j.atmosenv.2004.01.019</ext-link>, 2004.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Response of protonated, adduct, and fragmented ions in Vocus proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS)</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
      
Baasandorj, M., Millet, D. B., Hu, L., Mitroo, D., and Williams, B. J.: Measuring acetic and formic acid by proton-transfer-reaction mass spectrometry: sensitivity, humidity dependence, and quantifying interferences, Atmos. Meas. Tech., 8, 1303–1321, <a href="https://doi.org/10.5194/amt-8-1303-2015" target="_blank">https://doi.org/10.5194/amt-8-1303-2015</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
      
Cappellin, L., Karl, T., Probst, M., Ismailova, O., Winkler, P. M.,
Soukoulis, C., Aprea, E., Märk, T. D., Gasperi, F., and Biasioli, F.: On
Quantitative Determination of Volatile Organic Compound Concentrations Using
Proton Transfer Reaction Time-of-Flight Mass Spectrometry, Environ.
Sci. Technol., 46, 2283–2290, <a href="https://doi.org/10.1021/es203985t" target="_blank">https://doi.org/10.1021/es203985t</a>,
2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
      
Claflin, M. S., Pagonis, D., Finewax, Z., Handschy, A. V., Day, D. A., Brown, W. L., Jayne, J. T., Worsnop, D. R., Jimenez, J. L., Ziemann, P. J., de Gouw, J., and Lerner, B. M.: An in situ gas chromatograph with automatic detector switching between PTR- and EI-TOF-MS: isomer-resolved measurements of indoor air, Atmos. Meas. Tech., 14, 133–152, <a href="https://doi.org/10.5194/amt-14-133-2021" target="_blank">https://doi.org/10.5194/amt-14-133-2021</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
      
Cui, L., Zhang, Z., Huang, Y., Lee, S. C., Blake, D. R., Ho, K. F., Wang, B., Gao, Y., Wang, X. M., and Louie, P. K. K.: Measuring OVOCs and VOCs by PTR-MS in an urban roadside microenvironment of Hong Kong: relative humidity and temperature dependence, and field intercomparisons, Atmos. Meas. Tech., 9, 5763–5779, <a href="https://doi.org/10.5194/amt-9-5763-2016" target="_blank">https://doi.org/10.5194/amt-9-5763-2016</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
      
de Gouw, J. and Warneke, C.: Measurements of volatile organic compounds in
the earths atmosphere using proton-transfer-reaction mass spectrometry, Mass
Spectrom. Rev., 26, 223–257, <a href="https://doi.org/10.1002/mas.20119" target="_blank">https://doi.org/10.1002/mas.20119</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
      
de Gouw, J. A., Goldan, P. D., Warneke, C., Kuster, W. C., Roberts, J. M.,
Marchewka, M., Bertman, S. B., Pszenny, A. A. P., and Keene, W. C.:
Validation of proton transfer reaction-mass spectrometry (PTR-MS)
measurements of gas-phase organic compounds in the atmosphere during the New
England Air Quality Study (NEAQS) in 2002, J. Geophys. Res.-Atmos., 108, 4682,  <a href="https://doi.org/10.1029/2003JD003863" target="_blank">https://doi.org/10.1029/2003JD003863</a>, 2003.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
      
Ellis, A. M. and Mayhew, C. A.: Chemical Ionization: Chemistry,
Thermodynamics and Kinetics, in: Proton Transfer Reaction Mass Spectrometry, Wiley,
25–48, <a href="https://doi.org/10.1002/9781118682883.ch2" target="_blank">https://doi.org/10.1002/9781118682883.ch2</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
      
Gueneron, M., Erickson, M. H., VanderSchelden, G. S., and Jobson, B. T.:
PTR-MS fragmentation patterns of gasoline hydrocarbons, Int.
J. Mass Spectrom., 379, 97–109,
<a href="https://doi.org/10.1016/j.ijms.2015.01.001" target="_blank">https://doi.org/10.1016/j.ijms.2015.01.001</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
      
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., and
Lindinger, W.: Proton transfer reaction mass spectrometry: on-line trace gas
analysis at the ppb level, Int. J. Mass Spectrom.
Ion Process., 149–150, 609–619,
<a href="https://doi.org/10.1016/0168-1176(95)04294-U" target="_blank">https://doi.org/10.1016/0168-1176(95)04294-U</a>, 1995.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
      
Hartungen, E. v., Wisthaler, A., Mikoviny, T., Jaksch, D., Boscaini, E.,
Dunphy, P. J., and Märk, T. D.: Proton-transfer-reaction mass
spectrometry (PTR-MS) of carboxylic acids: Determination of Henry's law
constants and axillary odour investigations, Int. J. Mass
Spectrom., 239, 243–248, <a href="https://doi.org/10.1016/j.ijms.2004.09.009" target="_blank">https://doi.org/10.1016/j.ijms.2004.09.009</a>,
2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
      
Inomata, S., Tanimoto, H., Kameyama, S., Tsunogai, U., Irie, H., Kanaya, Y., and Wang, Z.: Technical Note: Determination of formaldehyde mixing ratios in air with PTR-MS: laboratory experiments and field measurements, Atmos. Chem. Phys., 8, 273–284, <a href="https://doi.org/10.5194/acp-8-273-2008" target="_blank">https://doi.org/10.5194/acp-8-273-2008</a>, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
      
Jensen, A., Liu, Z., Tan, W., Dix, B., Chen, T., Koss, A., Zhu, L., Li, L.,
and de Gouw, J.: Measurements of Volatile Organic Compounds During the
COVID-19 Lockdown in Changzhou, China, Geophys. Res. Lett., 48,
e2021GL095560, <a href="https://doi.org/10.1029/2021GL095560" target="_blank">https://doi.org/10.1029/2021GL095560</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
      
Kari, E., Miettinen, P., Yli-Pirilä, P., Virtanen, A., and Faiola, C.
L.: PTR-ToF-MS product ion distributions and humidity-dependence of biogenic
volatile organic compounds, Int. J. Mass Spectrom., 430,
87–97, <a href="https://doi.org/10.1016/j.ijms.2018.05.003" target="_blank">https://doi.org/10.1016/j.ijms.2018.05.003</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
      
Krechmer, J., Lopez-Hilfiker, F., Koss, A., Hutterli, M., Stoermer, C.,
Deming, B., Kimmel, J., Warneke, C., Holzinger, R., Jayne, J., Worsnop, D.,
Fuhrer, K., Gonin, M., and de Gouw, J.: Evaluation of a New Reagent-Ion
Source and Focusing Ion–Molecule Reactor for Use in
Proton-Transfer-Reaction Mass Spectrometry, Anal. Chem., 90, 12011–12018,
<a href="https://doi.org/10.1021/acs.analchem.8b02641" target="_blank">https://doi.org/10.1021/acs.analchem.8b02641</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
      
Li, F., Huang, D. D., Tian, L., Bin, Y., Wen, T., Zhu, L., Ye, P., Worsnop, D., Hoi, K. I., Mok, K. M., and Li, Y. J.: Response of protonated, adduct, and fragmented ions in Vocus proton-transfer-reaction time-of-flight mass (PTR-ToF-MS) spectrometer, Zenodo [data set], <a href="https://zenodo.org/records/10947779" target="_blank"/>​​​​​​​ (last access: 23 April 2024), 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
      
Li, H., Almeida, T. G., Luo, Y., Zhao, J., Palm, B. B., Daub, C. D., Huang, W., Mohr, C., Krechmer, J. E., Kurtén, T., and Ehn, M.: Fragmentation inside proton-transfer-reaction-based mass spectrometers limits the detection of ROOR and ROOH peroxides, Atmos. Meas. Tech., 15, 1811–1827, <a href="https://doi.org/10.5194/amt-15-1811-2022" target="_blank">https://doi.org/10.5194/amt-15-1811-2022</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
      
Lindinger, W., Hansel, A., and Jordan, A.: On-line monitoring of volatile
organic compounds at pptv levels by means of proton-transfer-reaction mass
spectrometry (PTR-MS) medical applications, food control and environmental
research, Int. J. Mass Spectrom. Ion Process., 173,
191–241, <a href="https://doi.org/10.1016/S0168-1176(97)00281-4" target="_blank">https://doi.org/10.1016/S0168-1176(97)00281-4</a>, 1998.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
      
Materić, D., Lanza, M., Sulzer, P., Herbig, J., Bruhn, D., Gauci, V.,
Mason, N., and and Turner, C.: Selective reagent ion-time of flight-mass
spectrometry study of six common monoterpenes, Int. J. Mass
Spectrom., 421, 40–50, <a href="https://doi.org/10.1016/j.ijms.2017.06.003" target="_blank">https://doi.org/10.1016/j.ijms.2017.06.003</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
      
Michoud, V., Sauvage, S., Léonardis, T., Fronval, I., Kukui, A., Locoge, N., and Dusanter, S.: Field measurements of methylglyoxal using proton transfer reaction time-of-flight mass spectrometry and comparison to the DNPH–HPLC–UV method, Atmos. Meas. Tech., 11, 5729–5740, <a href="https://doi.org/10.5194/amt-11-5729-2018" target="_blank">https://doi.org/10.5194/amt-11-5729-2018</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
      
Pagonis, D., Sekimoto, K., and de Gouw, J.: A Library of Proton-Transfer
Reactions of H<sub>3</sub>O+ Ions Used for Trace Gas Detection, J. Am. Soc. Mass. Spectr.,
30, 1330–1335, <a href="https://doi.org/10.1007/s13361-019-02209-3" target="_blank">https://doi.org/10.1007/s13361-019-02209-3</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
      
Pleil, J. D., Hansel, A., and Beauchamp, J.: Advances in proton transfer
reaction mass spectrometry (PTR-MS): applications in exhaled breath
analysis, food science, and atmospheric chemistry, J. Breath Res., 13, 039002,
<a href="https://doi.org/10.1088/1752-7163/ab21a7" target="_blank">https://doi.org/10.1088/1752-7163/ab21a7</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
      
Salazar Gómez, J. I., Sojka, M., Klucken, C., Schlögl, R., and
Ruland, H.: Determination of trace compounds and artifacts in nitrogen
background measurements by proton transfer reaction time-of-flight  under dry and humid conditions, J. Mass. Spectrom., 56, e4777,
<a href="https://doi.org/10.1002/jms.4777" target="_blank">https://doi.org/10.1002/jms.4777</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
      
Schripp, T., Etienne, S., Fauck, C., Fuhrmann, F., Märk, L., and
Salthammer, T.: Application of proton-transfer-reaction-mass-spectrometry
for Indoor Air Quality research, Indoor Air, 24, 178–189,
<a href="https://doi.org/10.1111/ina.12061" target="_blank">https://doi.org/10.1111/ina.12061</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
      
Sekimoto, K., Li, S.-M., Yuan, B., Koss, A., Coggon, M., Warneke, C., and de
Gouw, J.: Calculation of the sensitivity of proton-transfer-reaction mass
spectrometry (PTR-MS) for organic trace gases using molecular properties,
Int. J. Mass Spectrom., 421, 71–94,
<a href="https://doi.org/10.1016/j.ijms.2017.04.006" target="_blank">https://doi.org/10.1016/j.ijms.2017.04.006</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
      
Sekimoto, K. and Koss, A. R.: Modern mass spectrometry in atmospheric
sciences: Measurement of volatile organic compounds in the troposphere using
proton-transfer-reaction mass spectrometry, J. Mass Spectrom., 56,
<a href="https://doi.org/10.1002/jms.4619" target="_blank">https://doi.org/10.1002/jms.4619</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
      
Shao, P., An, J., Xin, J., Wu, F., Wang, J., Ji, D., and Wang, Y.: Source
apportionment of VOCs and the contribution to photochemical ozone formation
during summer in the typical industrial area in the Yangtze River Delta,
China, Atmos. Res., 176–177, 64–74,
<a href="https://doi.org/10.1016/j.atmosres.2016.02.015" target="_blank">https://doi.org/10.1016/j.atmosres.2016.02.015</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
      
Shrivastava, M., Cappa, C. D., Fan, J., Goldstein, A. H., Guenther, A. B.,
Jimenez, J. L., Kuang, C., Laskin, A., Martin, S. T., Ng, N. L., Petaja, T.,
Pierce, J. R., Rasch, P. J., Roldin, P., Seinfeld, J. H., Shilling, J.,
Smith, J. N., Thornton, J. A., Volkamer, R., Wang, J., Worsnop, D. R.,
Zaveri, R. A., Zelenyuk, A., and Zhang, Q.: Recent advances in understanding
secondary organic aerosol: Implications for global climate forcing, Rev.
Geophys., 55, 509–559, <a href="https://doi.org/10.1002/2016RG000540" target="_blank">https://doi.org/10.1002/2016RG000540</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
      
Sinha, V., Custer, T. G., Kluepfel, T., and Williams, J.: The effect of
relative humidity on the detection of pyrrole by PTR-MS for OH reactivity
measurements, Int. J. Mass Spectrom., 282, 108–111,
<a href="https://doi.org/10.1016/j.ijms.2009.02.019" target="_blank">https://doi.org/10.1016/j.ijms.2009.02.019</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
      
Smith, D., Diskin, A., Ji, Y. F., and Spanel, P.: Concurrent use of H3O+,
NO+, and O-2(+) precursor ions for the detection and quantification of
diverse trace gases in the presence of air and breath by selected ion-flow
tube mass spectrometry, Int. J. Mass Spectrom., 209,
81–97, <a href="https://doi.org/10.1016/S1387-3806(01)00478-X" target="_blank">https://doi.org/10.1016/S1387-3806(01)00478-X</a>, 2001.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
      
Ŝpaněl, P.  and Smith, D.: SIFT studies of the reactions of H<sub>3</sub>O<sub>+</sub>,
NO<sub>+</sub> and O<sub>+2</sub> with a series of volatile carboxylic acids and esters,
Int. J. Mass Spectrom. Ion Process., 172, 137–147,
<a href="https://doi.org/10.1016/S0168-1176(97)00246-2" target="_blank">https://doi.org/10.1016/S0168-1176(97)00246-2</a>, 1998.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
      
Ŝpaněl, P. and Smith, D.: Selected ion flow tube: a technique for
quantitative trace gas analysis of air and breath, Med. Biol.
Eng. Comput., 34, 409–419, <a href="https://doi.org/10.1007/BF02523843" target="_blank">https://doi.org/10.1007/BF02523843</a>,
1996.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
      
Ŝpaněl, P., Ji, Y., and Smith, D.: SIFT studies of the reactions of
H<sub>3</sub>O<sub>+</sub>, NO<sub>+</sub> and O<sub>2+</sub> with a series of aldehydes and ketones,
Int. J. Mass Spectrom. Ion Process., 165–166,
25–37, <a href="https://doi.org/10.1016/S0168-1176(97)00166-3" target="_blank">https://doi.org/10.1016/S0168-1176(97)00166-3</a>, 1997.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
      
Ŝpaněl, P.  and Smith, D.: Influence of water vapour on selected ion flow
tube mass spectrometric analyses of trace gases in humid air and breath,
Rapid Commun. Mass Spectrom., 14, 1898–1906,
<a href="https://doi.org/10.1002/1097-0231(20001030)14:20&lt;1898::AID-RCM110&gt;3.0.CO;2-G" target="_blank">https://doi.org/10.1002/1097-0231(20001030)14:20&lt;1898::AID-RCM110&gt;3.0.CO;2-G</a>, 2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
      
Steinbacher, M., Dommen, J., Ammann, C., Spirig, C., Neftel, A., and Prevot,
A. S. H.: Performance characteristics of a proton-transfer-reaction mass
spectrometer (PTR-MS) derived from laboratory and field measurements,
Int. J. Mass Spectrom., 239, 117–128,
<a href="https://doi.org/10.1016/j.ijms.2004.07.015" target="_blank">https://doi.org/10.1016/j.ijms.2004.07.015</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
      
Vlasenko, A., Macdonald, A. M., Sjostedt, S. J., and Abbatt, J. P. D.: Formaldehyde measurements by Proton transfer reaction – Mass Spectrometry (PTR-MS): correction for humidity effects, Atmos. Meas. Tech., 3, 1055–1062, <a href="https://doi.org/10.5194/amt-3-1055-2010" target="_blank">https://doi.org/10.5194/amt-3-1055-2010</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
      
Wang, Y., Yang, G., Lu, Y., Liu, Y., Chen, J., and Wang, L.: Detection of
gaseous dimethylamine using vocus proton-transfer-reaction time-of-flight
mass spectrometry, Atmos. Environ., 243, 117875,
<a href="https://doi.org/10.1016/j.atmosenv.2020.117875" target="_blank">https://doi.org/10.1016/j.atmosenv.2020.117875</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
      
Warneke, C., van der Veen, C., Luxembourg, S., de Gouw, J. A., and Kok, A.:
Measurements of benzene and toluene in ambient air using
proton-transfer-reaction mass spectrometry: calibration, humidity
dependence, and field intercomparison, Int. J. Mass
Spectrom., 207, 167–182, <a href="https://doi.org/10.1016/S1387-3806(01)00366-9" target="_blank">https://doi.org/10.1016/S1387-3806(01)00366-9</a>,
2001.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
      
Warneke, C., De Gouw, J. A., Kuster, W. C., Goldan, P. D., and Fall, R.:
Validation of atmospheric VOC measurements by proton-transfer-reaction mass
spectrometry using a gas-chromatographic preseparation method, Environ. Sci.
Technol., 37, 2494–2501, <a href="https://doi.org/10.1021/es026266i" target="_blank">https://doi.org/10.1021/es026266i</a>, 2003.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
      
Warneke, C., Veres, P., Holloway, J. S., Stutz, J., Tsai, C., Alvarez, S., Rappenglueck, B., Fehsenfeld, F. C., Graus, M., Gilman, J. B., and de Gouw, J. A.: Airborne formaldehyde measurements using PTR-MS: calibration, humidity dependence, inter-comparison and initial results, Atmos. Meas. Tech., 4, 2345–2358, <a href="https://doi.org/10.5194/amt-4-2345-2011" target="_blank">https://doi.org/10.5194/amt-4-2345-2011</a>, 2011.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
      
Yuan, B., Koss, A. R., Warneke, C., Coggon, M., Sekimoto, K., and de Gouw,
J. A.: Proton-Transfer-Reaction Mass Spectrometry: Applications in
Atmospheric Sciences, Chem. Rev., 117, 13187–13229,
<a href="https://doi.org/10.1021/acs.chemrev.7b00325" target="_blank">https://doi.org/10.1021/acs.chemrev.7b00325</a>, 2017.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
      
Zhao, J. and Zhang, R.: Proton transfer reaction rate constants between
hydronium ion (H<sub>3</sub>O+) and volatile organic compounds, Atmos.
Environ., 38, 2177–2185, <a href="https://doi.org/10.1016/j.atmosenv.2004.01.019" target="_blank">https://doi.org/10.1016/j.atmosenv.2004.01.019</a>,
2004.

    </mixed-citation></ref-html>--></article>