Methodology and uncertainty estimation for measurements of methane leakage in a manufactured house
Michael F. Link
Rileigh Robertson
Tyler Boyle
Dustin Poppendieck
Methane emissions from natural gas appliances and infrastructure within buildings have historically not been captured in greenhouse gas inventories, leading to under-estimates, especially in urban areas. Recent measurements of these post-meter emissions have indicated non-negligible emissions within residences, with impacts on both indoor air quality and climate. As a result, methane losses from residential buildings have been included in the latest US national inventory, with emission factors determined from a single study of homes in California. To facilitate future additional studies investigating building methane emissions, we conducted a controlled experiment to document a methodology for such measurements and estimated associated uncertainties. We determined whole-house methane emission rates with a mass balance approach using near-simultaneous measurements of indoor and outdoor methane mole fractions at a manufactured house. We quantified the uncertainty in whole-house methane emission rates by varying the forced outdoor air ventilation rate of the manufactured house, measuring the outdoor air change rate using both sulfur hexafluoride and carbon dioxide tracers, and performing methane injections at prescribed rates. We found that the whole-house quiescent methane emission rate (i.e., emission rate when all gas appliances were off) in the manufactured house averaged 0.33 g d−1 with methodological errors in the calculated emission rates of approximately 19 % (root-mean-square deviation). We also measured the quiescent leakage from the manufactured house over 3 months to find 26 % (1σ) variability in emissions over two seasons. Our findings can be used to inform plans for future studies quantifying indoor methane losses downstream of residential meters using similar methods. Such quantification studies are sorely needed to better understand building methane emissions and their drivers to inform inventories and plan mitigation strategies.
- Article
(2561 KB) - Full-text XML
- BibTeX
- EndNote
Methane is the second largest contributor to climate warming after carbon dioxide (CO2), with a global warming potential (ability to trap heat in the atmosphere) 27 to 30 times greater than that of CO2 on a 100-year basis or 80 to 83 times greater on a 20-year basis (IPCC, 2021). Methane also plays a role as a precursor to tropospheric ozone (Mar et al., 2022). Nearly half of all residences in the United States use natural gas, whose chief constituent is methane, for one or more appliances within the dwelling (AGA, 2021; EIA, 2023). Leakage of natural gas from appliances and pipes within residential dwellings, in addition to being a concern for indoor air quality, leads to emissions that exfiltrate to the outdoor air. Assessing future global warming impacts of methane requires accurate accounting for fugitive gas leaks and losses in distribution systems. Historically, there have been two methods for calculating these leakages on a regional scale: top down (e.g., using atmospheric methane concentrations to estimate regional emissions) and bottom up (e.g., multiplying the average leakage from a pipe section by the total length of pipes in a region). Recent top-down estimates of methane emissions from urban areas are larger than accounted for using bottom-up methods (Plant et al., 2019; Yadav et al., 2023; Lopez-Coto et al., 2020; Sargent et al., 2021). Historically, bottom-up methane emission inventories have not accounted for natural gas losses downstream of residential gas meters, possibly contributing to this discrepancy between top-down and bottom-up estimates in urban areas. Recent studies at both the appliance and whole-house level have shown that quiescent leakage of gas during periods with appliances off, emissions during on/off cycling of appliances, and emissions during appliance use (including from potential inefficient combustion) can account for a significant portion of a region's total methane emissions (Lebel et al., 2022; Merrin and Francisco, 2019; Saint-Vincent and Pekney, 2020). Measurements of emissions from 75 homes in California indicated that typical homes have quiescent methane emission rates (including emissions from pilot lights) of < 1 g d−1 but with some as high as 10 g d−1, with total emissions from residential natural gas, i.e., including both quiescent emissions and emissions from steady operation of appliances, accounting for approximately 15 % of California's natural gas emissions (Fischer et al., 2018). Consequently, the US Environmental Protection Agency (EPA) recently included quiescent residential emissions of methane in its 2022 inventory, using values from the Fischer et at. (2018) study (EPA, 2022).
Historically most indoor emission rate studies have been targeted at quantifying emissions of formaldehyde and subsets of volatile organic compounds (VOCs). The most common approach for determining emission rates for various chemicals indoors is measuring the emissions of individual sources using environmental chambers and then using models to extrapolate to the individual source emission rates in an entire building (Kelly et al., 1999; Liang et al., 2012; Mølhave et al., 1996). One drawback of this approach is the difficulty in ensuring the models account for all potential emission sources. Additionally, measuring emissions in environmental chambers can be labor-intensive, time-consuming, and expensive. Another approach to quantifying whole-house emission rates for various chemicals is the mass balance method (Hodgson et al., 2002; Offermann and Hodgson, 2011; Liang and Yang, 2013; Li et al., 2019). For methane this approach can quantify the sum of all leaks in the entire volume of the house. The methane emission rate is determined by comparing the concentration of the chemical indoors and outdoors while knowing the outdoor air change rate (ACR) of the house. To the best of our knowledge, Fischer et al. (2018) is the only study to have quantified whole-house methane emissions, using blower door and tracer decay tests to determine the ACR in a mass balance approach. More recently, Nicholas et al. (2023) measured indoor methane leaks using a closed-chamber method, demonstrating the method's accuracy in a study of 20 buildings in greater Boston, Massachusetts, USA. In this method, the basement of the building was sealed off and a mass balance equation applied assuming an ACR of zero (i.e., that no methane exited the closed space).
A common method for calculating the ACR in a residence is tracer decay analysis using either sulfur hexafluoride (SF6) or CO2 as the trace gas (ASTM, 2023). Each tracer has its advantages and disadvantages. CO2 has a measurable, varying outdoor background concentration, while outdoor SF6 concentrations are sufficiently small relative to the high concentrations injected such that they can be neglected for the ACR determination. SF6 analysis requires laboratory-grade analytical equipment, while less-expensive commercial CO2 sensors are readily available. Due to instrument detection limits and background CO2 concentrations, the number of moles of CO2 required for a tracer test is over 3 orders of magnitude higher than for SF6; however, the global warming potential of SF6 is over 24 000 times greater than that of CO2 (IPCC, 2021). Thus, under typical instrument detection limits CO2 as a tracer has a smaller global warming impact than SF6. A few studies have quantified the uncertainty in tracer decay ACR measurements using each of these tracers. For example, Poppendieck et al. (2015) injected SF6 as a tracer and estimated a 10 % measurement error in the ACR, while Huangfu et al. (2020) used CO2 injections to calculate ACRs with an estimated uncertainty of 20 %.
Here we demonstrate a mass balance method for estimating whole-house methane emission rates using a tracer decay ACR measurement and determine the uncertainty associated with the method. The 3.5-month study was performed in the National Institute of Standards and Technology (NIST) manufactured house (Nabinger and Persily, 2008; Nabinger et al., 2010). We note that while only 5.5 % of US housing units are manufactured houses (i.e., mobile homes) such as this one, over 61 % are one-unit detached homes (US Census American Community Survey, 2023); the methodology described here is relevant to detached houses in which mixing can be ensured or imposed through mechanical systems. In our study, we first compared the whole-house ACR estimated using either CO2 or SF6 as a tracer while varying the operation of the forced outdoor air ventilation system of the manufactured house (i.e., exhaust and whole-house fans). Then, we injected methane at specified known flow rates and quantified the error in the mass balance calculation of the overall house methane emission rate. Finally, we calculated quiescent whole-house methane emission rates (i.e., with no injections or operation of appliances) daily over several months, analyzing their variability to determine how representative one measurement is of long-term emissions. Our experimental goal was to develop an easily deployable and scalable means of measuring building emission rates while documenting possible sources of error and associated uncertainties.
We performed the experiments described above in a manufactured house (also called a mobile home in the United States) on the NIST campus in Gaithersburg, Maryland, between October 2023 and January 2024. The one-story house has three bedrooms and two bathrooms, a floor area of 133 m2, and a volume of 324 m3. The house is equipped with a gas stove and exhaust fan in the kitchen, a gas furnace, and a whole-house exhaust fan (Fig. 1). Neither the stove nor the furnace has a pilot light. The exhaust fans allowed control of the ACR in the house between 0.2 and 2.5 h−1. All tests were performed with all windows and doors closed. A single heating, ventilation, and air conditioning (HVAC) return was located at the HVAC unit, with supply air distributed throughout the house. The HVAC fan (fan speed 2000 m3 h−1) was operating throughout the experiment to ensure well-mixed conditions within the house. Instrumentation measured indoor and outdoor methane and CO2 and indoor SF6 (outdoor SF6 concentrations were indistinguishable from background). These measurements allowed for the determination of the ACR in the house as well as the indoor emissions of methane.
2.1 Instrumentation for trace gas sampling
Mole fractions of CO2 and methane were measured at approximately 2.5 s intervals by a cavity ring-down spectrometric (CRDS) analyzer and are reported here in micromoles per mole (µmol mol−1), often also referred to as parts per million (ppm). A valve automatically switched between two different perfluoroalkoxy (PFA) 0.95 cm (3/8 in) outer-diameter inlet lines at 5 min intervals. One inlet drew outdoor air from a 1.5 m mast located 2.4 m outside the house, and the other drew air from inside the house, at locations indicated in Fig. 1. Both lines were connected to particulate filters (polytetrafluoroethylene (PTFE), 47 mm diameter, 0.45 µm pore size) at their inlets. A flush pump pulled air at 10 L min−1 through the appropriate inlet line. Several additional instruments were simultaneously drawing air from the common side of the valve upstream of the flush pump, including the CRDS analyzer, which was set to a flow rate of approximately 70 mL min−1. SF6 was measured inside the house using a time-of-flight proton-transfer mass spectrometer (PTR-MS). SF6 was quantified from the SF3O+ ion signal. The PTR-MS sampled SF6 through 8 mm (inner-diameter) PFA tubing with an inlet flow rate of 120 mL min−1 from a line that was flushed at 15 L min−1.
Indoor and outdoor temperature and heating and cooling activity in the house were logged by a smart thermostat. Indoor air temperatures were used to calculate air number densities. Differential pressure measurements indicated that the difference between indoor and outdoor pressures never exceeded 10 Pa, so the outdoor pressure from a weather station at the Montgomery County Airpark 6.8 km away (NOAA, 2024) was used for both indoor and outdoor molar calculations. We also used wind speed data from this same station in Sect. 3.1 to look for correlations between ventilation rates and wind speed. While the HVAC fan was on for all experiments, the gas heating furnace was turned off for the tracer experiments, which ended in October. The gas heating was turned on in late December, cycling on and off to maintain a minimum temperature set point during some of the quiescent emissions measurements. The duration that the heating element of the furnace was running was logged by the thermostat. The electrically powered whole-house air conditioning system was active during most of the experiments when the heating element was not used.
2.2 Injections of methane, CO2, and SF6
Methane, CO2, and SF6 were injected from standard cylinders using mass flow controllers, controlled by a custom automated system, into the house during the measurement campaign. For the ACR calculations, a mixture of 5 % SF6 (volume fraction) in nitrogen was injected at rate of 90 mL min−1 for 2 min, achieving mole fractions of approximately 30 nmol mol−1. Pure CO2 (99.9 % mole fraction) was injected at approximately 5 L min−1 for 1 h, typically achieving mole fractions between 100 and 600 µmol mol−1 above outdoor values. Both CO2 and SF6 were injected into the HVAC air intake so that they were dispersed though the vents throughout the house; previous research in this house has shown that the tracers injected this way disperse (sufficiently for the ACR calculation) within 10 min. When both CO2 and SF6 were injected on the same day, injections were set up to end at the same time to achieve the best comparison between ACR calculated using the two tracers. During the methane tracer experiments, methane was injected at a constant rate for a 24 h period at a location near the HVAC system (Fig. 1) but not into the HVAC intake. Methane measurements for the experiments were made well after injection began (at least 3 h) and after near-steady-state had been achieved in the concentrations; we assume it was sufficiently well-mixed in the volume by the HVAC fan system by that time. The volumetric flow rate of methane from the mass flow controller was calibrated using a volumetric flow meter (manufacturer-accredited by ISO and NIST) over a range to include the methane flow rates used for the injection experiments.
2.3 Processing of raw mole fraction data
CO2 and methane mole fraction measurements from the CRDS analyzer were initially processed as described below. The analyzer recorded data at a resolution of 2.5 s. The values were separated into indoor and outdoor time series using the timing of the valve switching (every 5 min), which was logged separately. The first 60 s after and last 30 s prior to each valve switching event were removed to account for analyzer response time and any discrepancies in timing. For both indoor and outdoor data, the remaining measurements for each sample period were averaged. The indoor and outdoor 5 min means were then interpolated in time so that for each 5 min interval there was a corresponding indoor and outdoor value (i.e., using the mean of the adjacent measurements to fill the missing intervals for each). The outdoor methane measurements exhibited some high-variability time periods during which plumes of methane traveled past the inlet line for periods shorter than 5 min, so these measurements were then smoothed using a 1 h rolling average to eliminate high-frequency variability.
The water vapor levels inside and outside the house were different, especially during sampling in December and January. Hence, the reported dry-air mole fractions were converted to wet-air mole fractions for mass balance calculations. The internal CRDS water-vapor-corrected value for CO2 and methane mole fractions includes a correction for both the dilution and spectroscopic influences on the measurement (Rella et al., 2013); thus we used the reported dry-water-corrected values and then calculated the dilution only to obtain the true wet-air mole fractions following Eq. (1):
where XH2O is the mole fraction of water vapor as measured by the CRDS instrument, XC,dry is the dry-air mole fraction of either methane or CO2, and XC,wet is the dilution-corrected wet-air mole fraction (XC,wet is simplified to X in subsequent equations). The initial data processing described above resulted in a time series at 5 min intervals of indoor, outdoor, and smoothed outdoor values that were used in subsequent analyses of methane and CO2. Figure 2 shows an example of the raw time series data along with the resulting processed data from 8–11 October 2023, a period with three different methane injection rates along with daily CO2 injection spikes for the ACR determination.
2.4 Mass balance
To estimate either the ACR or emission rate in the house volume, we used a mass balance approach, retaining molar units without assuming constant density across indoor and outdoor air. The governing equation for a mass balance of an inert tracer (methane, CO2, or SF6 in this study) in an indoor volume is (Nazaroff and Cass, 1986)
where ER(t) (g h−1) is the emission rate into the house at time t; MW is the molar mass (g mol−1) of the trace gas in question; and nair represents the moles of air inside the house volume, calculated assuming an ideal gas as , where P and T are the pressure and temperature inside the house, respectively; V is the volume of the house; and R=8.314 J (mol K)−1 is the ideal gas constant. X(t) is the mole fraction (moles of tracer per mole of air) within the volume, Xo(t) is the mole fraction outside (both functions of time t), and ACR is the air change rate in the house (h−1), or , where is the molar flow rate of air (mol h−1) into or out of the volume (assumed equal).
Note that mole fraction is used in Eq. (2) rather than a mass per volume concentration, as indicated in previous work (e.g., Lebel et al., 2022). This is necessary to account for the variation in temperatures between inside and outside during the fall and winter seasons, causing the volume flow rate into and out of the house not to be equivalent. Not accounting for temperature changes during large differences between indoor and outdoor temperatures can lead to errors of up to 100 % in calculating small emission rates (such as our measured quiescent methane emission rates of < 0.5 g d−1) using this method. Similarly, as noted in Sect. 2.3, the wet-air mole fraction of methane or CO2, rather than the dry-air mole fraction, was used to account for differences in water vapor between inside and outside, which also could impact the calculation. In both cases, the errors introduced by not using the above methods are largest when the mole fraction difference between indoors and outdoors is smallest because small errors in the mole fraction differences have a large relative impact on the calculated emission rate. These effects are negligible when using Eq. (2) for the ACR calculation, as the indoor–outdoor mole fraction differences are very large by design during those measurements.
2.5 Air change rate calculation
ACRs were calculated following ASTM tracer decay method E741 (ASTM, 2023) using either CO2 (ACR) or SF6 (ACRSF6) as the tracer. It was assumed the air in the house was well-mixed due to the continuous operation of the HVAC recirculation fan, based on preliminary measurements of the tracers at multiple locations in the house. After injecting the tracer such that X≫X0 and then ceasing all emissions so that ER(t)=0, the decay of X inside the volume is expressed as
Solving this first-order differential equation with the assumption that Xo is constant over the time period gives
where A is the natural log of the peak mole fraction difference, a constant. For our experiments, SF6 and/or CO2 were injected into the house (see Sect. 2.2) for a defined period of time. This allowed mole fractions to decay with no disturbance in the house (i.e., no personnel) resulting in no indoor sources of CO2. The period for the decay calculation began 10 min after the peak tracer mole fraction was measured to avoid noisy values or sharp transitions that may occur right after the injection ended. The end of the calculation period was determined as either the time at which (X−Xo) dropped to 33 % of its peak value or 1 h, whichever was greater. Xo, the outdoor mole fraction, was assumed to be zero for SF6. For CO2 calculations, we used a constant Xo in Eq. (4) that was the average of the outdoor smoothed mole fractions over the decay time. Following Eq. (4), the ACR was determined as the slope of the regression of the natural log of the difference between the indoor time-varying mole fraction and the constant outdoor mole fraction (or zero in the case of SF6) with time (Fig. 3).
2.6 Methane emission rate calculations
We calculated whole-house methane emission rate (ER(t) in Eq. 2) using two different experiments. For the first experiment, methane was injected at measured rates (using a flow controller, as described in Sect. 2.2) and at different ACRs, which were controlled by either turning all mechanical ventilation off, turning on only the stove exhaust fan, or turning on the whole-house ventilation system. The goal of this experiment was to evaluate how well the mass-balance-calculated emission rate (ERinjection,MB) based on Eq. (2) could replicate the emission rate as measured by the mass flow controller (ERinjection,MF) and to quantify an error associated with the method as applied here. The second experiment consisted of a longer-term analysis of the baseline quiescent emission rate (ERquiescent), i.e., the methane emitted from the house's gas infrastructure when there was no methane injection. The goal of this experiment was to determine how much ERquiescent varied over time, thus constraining how well a single measurement of the emission rate may represent a long-term average. We note that the average ERquiescent from the second experiment was subtracted from the total ER in the first experiment to determine ERinjection,MB.
Equation (2) was used to determine the methane emission rate from the house during both the methane injection (ERinjection,MB) and the quiescent experiments (ERquiescent,MB), using the ACR values that aligned closest in time with the methane measurement. Typically, the tracer gas decay time period for the ACR calculation overlapped with the period over which the methane emission rate was calculated, with start times for the tracer decay period always within 3.5 h of the start time of the methane emission rate calculation period. For a few days at the beginning of the experiment, the calculation was performed in the early morning (00:00 to 08:00 LT, local time) to avoid interference from researchers in the house during the day but was later changed to the local afternoon (13:00 to 19:00 LT), while also ensuring no personnel entered the house during those times. We found that conducting the experiment in the afternoon led to lower uncertainty in the outdoor mole fractions, as the outdoor mole fractions exhibited less variability during the afternoon when the atmosphere outside the house was more well-mixed due to atmospheric boundary layer dynamics. Figure 2 illustrates an example of two early morning periods with very high outdoor methane variability, while afternoon outdoor values were significantly more stable. Along with the ACR from a given day, each term on the right-hand side of Eq. (2) was averaged over the determined time period to calculate an average methane emission rate.
One uncertainty in the emission rate estimation method is the volume to use in the calculation. Excluding the HVAC closet and interior wall cavities, the house volume is 311 m3. If these volumes are added, the volume is 324 m3 (Fig. 1). The total volume measurement of the house including the exterior walls (excluding the attic and crawl space) is 340 m3. The emission rate calculation depends linearly on the volume of the space (as nair is the number of moles of air inside the house volume). Hence, depending on the volume chosen for the mass balance the emission rate could vary by 10 %. For this work we used a volume of 324 m3. We also note that this methodology may not capture all emissions that have made it into hidden spaces: wall cavities, crawl spaces, attics, and other spaces not directly connected to the living volume. To capture the emissions in such spaces using this methodology, either the volume of the house would need to be negatively pressurized relative to the hidden spaces or the hidden spaces would need to be connected (opened) to the main volume of the house with adequate mixing through the entire volume to ensure uniform concentrations.
3.1 Air change rate calculation
Air change rates (ACRs) were varied by changing the mechanical ventilation in the manufactured house. Without mechanical ventilation the ACR ranged between 0.1 and 0.5 h−1. Turning on the exhaust fan above the gas stove increased the ACR to between 0.6 and 0.8 h−1. Adding the whole-house fan to the gas stove exhaust fan further increased the ACR to between 2.2 and 2.5 h−1. A comparison between the ACRs determined from the two different tracers shows most differences to be less than 20 % with a mean absolute difference of 8.1 %. Generally, larger percent differences occurred at low ACRs where small absolute differences made a large impact (Fig. 4). At the highest ACRs (over 2 h−1) we found that using CO2 as the tracer resulted in lower ACRs (4% lower on average) than using SF6.
Nabinger et al. (2010) measured the ACR in the NIST manufactured house, finding that when no mechanical ventilation was operating, the ACR was a function of both the indoor–outdoor temperature difference and wind speed. We also found that without any mechanical ventilation, the ACR showed a positive correlation with both the indoor–outdoor temperature difference (R2=0.44) and wind speed at the nearby airport (R2=0.41). For the entire measurement period (using the daily SF6-calculated ACR under the conditions of no mechanical ventilation, N=48), the ACR was 0.27 h−1 with a standard deviation of 0.09 h−1, thus demonstrating a 32 % variability over indoor–outdoor temperature differences ranging from 0 to 20 °C and wind speeds between 0 and 9 m s−1. We did not observe correlations with temperature difference or wind when either the stove exhaust fan or whole-house fan was turned on (similarly to Nabinger et al., 2010). These results indicate that it is important to measure the ACR over the same time period as the emission rate because assuming a constant ACR could lead to significant error in the emission rate calculations.
3.2 Methane emission rate uncertainty estimated using injection experiments
In the first experiment, we compared methane emission rates calculated using the mass balance approach (Eq. 2, ERinjection,MB) with emission rates from mass-flow-controller measurements of injected methane (ERinjection,MF). To determine ERinjection,MB, the quiescent emission rate (ERquiescent,MB) was subtracted from the total emission calculated using the mass balance (ERtotal,MB):
Here we subtracted the mean ERquiescent,MB of the 35 measurements from experiments with no injection and all gas appliances turned off (0.014 g h−1 ± 0.004 g h−1 (1σ); results further described in Sect. 3.3). ERinjection,MB generally showed 1:1 agreement with ERinjection,MF with a slight under-estimation at low ACRs (dark blue data, Fig. 5).
We evaluated ERinjection,MB from both ACR and ACRSF6 separately against ERinjection,MF, using bias (the mean emission rate difference (ERinjection,MB – ERinjection,MF)), standard deviation of offsets (SD), and root-mean-square deviation (RMSD), as a percentage of ERinjection,MB (Table 1). These statistics, when evaluated separately for low and high ACRs, indicate that experiments at lower ACRs show a higher relative bias. When considering only higher ACRs, the errors are lower than at low ACRs, with RMSDs between 10 % and 14 %.
3.3 Quiescent whole-house emissions over time
We determined the whole-house emission rates (ERquiescent, with no gas appliances on and no methane injection) over a 3.5-month period. We present emission rates using the SF6-derived ACR, as those were consistently available for the 3.5-month duration. The average ERquiescent over all 35 test days with no heating was 0.33 g d−1 (0.014 g h−1) with a standard deviation of 0.08 g d−1 (0.004 g h−1). Emission rates did not show any trend across the test period (Fig. 6). We found no correlation of ERquiescent with outdoor temperature (which ranged from 0 °C to 26 °C during the experiments), indoor temperature, or ambient pressure.
The electric house HVAC system was in operation for the entire study, with the heating system disabled for most of the study, including for all the tracer injection experiments. For several days in late December and early January, however, the house natural gas heating system was enabled with the thermostat set to maintain a constant temperature of 20 °C (select days set at 22 °C). The number of minutes that the heat was on was logged, and emissions during time periods with the heat active (triangles in Fig. 6) were omitted from the mean ERquiescent calculation. Two of the three experiments conducted with the heat on show slightly higher emission rates than average, but one does not, and their magnitude does not correlate with the amount of time the heat was running. ERquiescent values for days during which the heat turned on during the 24 h prior to the experiment (plus symbols in Fig. 6) but not during the methane measurement itself do not appear to be impacted by the heating system, so they are included in the mean. Future experiments could be designed specifically to investigate the impact of the furnace on the whole-house emission rate, including the relationship between ERquiescent and how long the heat was running, how much gas was consumed, and how many times the furnace cycled on or off.
In this study, we used the NIST manufactured house to investigate methane emission rate measurements in a residential building. We measured air change rates (ACRs) using two different tracers in a decay method, used a tracer injection method to quantify errors in whole-house methane emission rate calculations, and measured quiescent methane emissions over a 3.5-month period to examine variability. Here we discuss our results, some likely sources of error, and recommendations for future studies.
One major drawback to measuring emissions using the mass balance method described here is that there is an assumption of emissions occurring within an enclosed envelope of known volume. Emissions occurring in crawl spaces, attics, and other areas that are not well-mixed relative to the rest of the house may not be captured, depending on varying differential pressures between the space and the sampled volume. Relatedly, the mass balance method assumes that the mixing within the enclosed space is perfect. For these experiments, we used an HVAC system fan that circulates tracers throughout the space, making this a reasonable assumption. However, that may not be the case in other houses. We also note that the requirement of a well-mixed volume prohibits the use of this method on high-rise buildings, such as multi-family complexes. Interzonal mixing (i.e., mixing between apartments or hallways) may make major contributions to the chemical composition of indoor air in any given space (e.g., an apartment) within a high-rise. This method would not work over the entire multi-unit high-rise because of the possible heterogeneous distribution of emission sources and non-uniform concentrations across different zones. However, if individual well-mixed zones can be pressurized relative to other units, this approach may still yield individual-zone (not whole-building) emission rates. In addition, the actual mixed volume must be known, as it is used directly in the emission rate calculation, so uncertainty in the volume measurement propagates directly to the results.
Several sources of uncertainty impact the measured mole fractions and their differences between indoor and outdoor air. One of the largest parameters impacting mole fraction uncertainty in our test is the variability in the outdoor methane mole fraction. Our experiment was sometimes conducted during periods of high outdoor methane variability, likely caused from leakage in the natural gas infrastructure on the NIST campus. Similar conditions are likely to be found in dense residential and urban areas that are surrounded by methane emissions sources. Performing experiments during the daytime when these emissions were more uniformly mixed around the house reduced the variability and therefore the uncertainty in the methane mole fraction infiltrating the house. Our emission rate testing also illustrated that accounting for temperature and humidity differences between indoor and outdoor air is important when estimating emission rates from small differences between indoor and outdoor air mole fractions. We also found that when using a high-precision CRDS instrument (1σ precision below 0.001 µmol mol−1 at 0.5 Hz), analyzer precision is not a significant factor in the error in the emission rate. However, if using lower-precision instruments, instrument precision and possible drift over experimental timescales should be considered in the analysis. The uncertainties described above are most significant when methane enhancements inside the house are small; larger methane enhancements inside (due to low ACR and/or high emission rates) would reduce the impact of uncertainties on the mole fractions.
We found that using CO2 as a tracer for the ACR calculation was nearly equivalent to using SF6, with ACRs agreeing within 8 % on average. During ACR tracer decay measurements, care should be taken to eliminate or at least minimize any additional ventilation of the house, such as personnel entering or exiting the spaces or opening any doors or windows. Additional caution must be exercised when using CO2 to eliminate interference from other CO2 sources (such as occupants or combustion in the house) and to inject enough CO2 to achieve a large signal relative to outside variability. Over the course of the 3.5-month study, the ACR in the manufactured house with no mechanical exhaust was variable (32 %) under the conditions of no mechanical ventilation. Therefore, timing the ACR measurement, especially for buildings without mechanical ventilation, should be as close as possible and during similar conditions to the emission rate measurement to help prevent variability in ACR from introducing error in the calculated emission.
Unlike the ACR, ERquiescent could not be measured simultaneously with the injected methane, as the mass balance method necessarily measures the total methane emission into the house. Thus, ERquiescent had to be subtracted from the total measured emission rate which included both the methane injection and the quiescent house emissions. We subtracted the average ERquiescent measured during the entire experiment from the total emission rate measured in each methane injection experiment, so day-to-day variability in ERquiescent contributed to error in the calculation.
Our measurements of whole-house quiescent methane emission rates in the manufactured house averaged 0.33 g d−1, similar to the mean of 0.5 g d−1 found by Fischer et al. (2018) in a study of 75 California single-family homes. Variability in this study from day to day was 0.08 g d−1 (standard deviation), or 26 % of the quiescent emission rate, similar to the 19 % estimated uncertainty from the methane injection experiments, indicating that this temporal variability is not distinguishable from our expected methodological error.
Our methane tracer injection results showed RMSD of 19 % on calculated emission rates, averaged over a range of ACRs and injected emissions. Errors were higher when ACRs were between 0.2 and 0.3 h−1 and not correlated to the magnitude of the indoor–outdoor methane differences. Specifically, emission rates calculated under the low-ACR conditions (0.2 to 0.3 h−1) were generally biased low over a range of emission rates. It is possible that the ACR calculated using the tracer decay method exhibited a low bias at lower ACRs, warranting further investigation. In general, while typical US single-family homes exhibit ACRs between 0.2 and 1 h−1 (Nazaroff, 2021; Reichman et al., 2017), newer homes are often built with reduced ACRs to achieve space heating and cooling efficiencies and reduce energy use. Given our results, when making measurements in spaces with low ACRs, it may be useful to turn on some mechanical ventilation for the test period. Higher ACRs also allow the methane mole fraction to come to equilibrium faster, which may make the testing quicker, but care should be taken if overall indoor enhancements are small because other errors have a larger relative impact when enhancements are small (as discussed above), and instrument detection limits may be approached. If possible, conducting methane injection tests prior to measuring emission rates from different houses would give the best estimate of uncertainty for each test given the different conditions likely to be encountered in a real-world experiment.
Additional measurements of whole-house emission rates of methane including from houses with different characteristics (i.e., age, location, and size) would be helpful to supplement the research performed here and to better inform national inventories (Karion et al., 2024). Future work could analyze the effects of gas appliance usage such as gas furnaces or stoves on whole-house emission rates. The average emission rates would likely increase with the use of these appliances (Lebel et al., 2022, 2020); hence investigating the relationship would be informative. Relationships relative to gas usage especially could shed light on recent top-down methane studies showing a relationship between emissions and monthly natural gas use over an entire urban area (Sargent et al., 2021; Zeng et al., 2023; Karion et al., 2023).
Weather data are available from NOAA (2024). Housing data are available from the US Census American Community Survey (2023). All other data and code used in this study are available by request to Anna Karion (anna.karion@nist.gov).
AK, DP, and MFL designed the experiments, and MFL, RR, AK, and TB carried them out. AK prepared the manuscript with contributions from all co-authors.
The contact author has declared that none of the authors has any competing interests.
Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.
The authors thank Lisa Ng and Kimberly Mueller (NIST) and the two external reviewers for their helpful comments.
This research has been supported by the NIST Greenhouse Gas Measurements Program and the NIST Engineering Laboratory.
This paper was edited by Albert Presto and reviewed by Hossein Maazallahi and one anonymous referee.
AGA: Gas Facts: Appliance and Housing Data, AGA (American Gas Association) [data set], https://www.aga.org/research-policy/resource-library/gas-facts-appliance-and-housing-data/, (last access: 25 April 2024), 2021.
ASTM: E 741 Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution, https://doi.org/10.1520/E0741-23, 2023.
EIA: Natural gas explained: Use of natural gas, https://www.eia.gov/energyexplained/natural-gas/use-of-natural-gas.php (last access: 25 April 2024), 2024.
EPA: Inventory of U.S. Greenhouse Gas Emissions and Sinks 1990–2020: Updates for Post-Meter Emissions, https://www.epa.gov/system/files/documents/2022-04/2022_ghgi_update_-_meter.pdf (last access: 14 December 2024), 2022.
Fischer, M. L., Chan, W. R., Delp, W., Jeong, S., Rapp, V., and Zhu, Z.: An Estimate of Natural Gas Methane Emissions from California Homes, Environ. Sci. Technol., 52, 10205–10213, https://doi.org/10.1021/acs.est.8b03217, 2018.
Hodgson, A. T., Beal, D., and McIlvaine, J. E.: Sources of formaldehyde, other aldehydes and terpenes in a new manufactured house, Indoor Air, 12, 235–242, https://doi.org/10.1034/j.1600-0668.2002.01129.x, 2002.
Huangfu, Y., Lima, N. M., O'Keeffe, P. T., Kirk, W. M., Lamb, B. K., Walden, V. P., and Jobson, B. T.: Whole-House Emission Rates and Loss Coefficients of Formaldehyde and Other Volatile Organic Compounds as a Function of the Air Change Rate, Environ. Sci. Technol., 54, 2143–2151, https://doi.org/10.1021/acs.est.9b05594, 2020.
IPCC: Climate Change 2021: The Physical Science Basis, Contribution of Working Group I to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change, Cambridge University Press, Cambridge, United Kingdom and New York, NY, USA, https://doi.org/10.1017/9781009157896, 2021.
Karion, A., Ghosh, S., Lopez-Coto, I., Mueller, K., Gourdji, S., Pitt, J., and Whetstone, J.: Methane Emissions Show Recent Decline but Strong Seasonality in Two US Northeastern Cities, Environ. Sci. Technol., 57, 19565–19574, https://doi.org/10.1021/acs.est.3c05050, 2023.
Karion, A., Shepson, P., Butcher, T., Commane, R., Fernandez, J. M., Ferrara, T., Hajny, K., Jackson, R., Lamb, B., Lopez-Coto, I., Magavi, Z., McDonald, B., Merrin, Z., Miller, S., Mueller, K., Murray, L., Pitt, J., Trieste, R., Trojanowski, R., and von Fischer, J.: Workshop on Quantifying Methane Emissions Across Natural Gas Infrastructure in Urban Environments, https://doi.org/10.6028/NIST.SP.1500-22, 2024.
Kelly, T. J., Smith, D. L., and Satola, J.: Emission Rates of Formaldehyde from Materials and Consumer Products Found in California Homes, Environ. Sci. Technol., 33, 81–88, https://doi.org/10.1021/es980592+, 1999.
Lebel, E. D., Finnegan, C. J., Ouyang, Z., and Jackson, R. B.: Methane and NOx Emissions from Natural Gas Stoves, Cooktops, and Ovens in Residential Homes, Environ. Sci. Technol., 56, 2529–2539, https://doi.org/10.1021/acs.est.1c04707, 2022.
Lebel, E. D., Lu, H. S., Speizer, S. A., Finnegan, C. J., and Jackson, R. B.: Quantifying Methane Emissions from Natural Gas Water Heaters, Environ. Sci. Technol., 54, 5737–5745, https://doi.org/10.1021/acs.est.9b07189, 2020.
Li, B., Cheng, Z., Yao, R., Wang, H., Yu, W., Bu, Z., Xiong, J., Zhang, T., Essah, E., Luo, Z., Shahrestani, M., and Kipen, H.: An investigation of formaldehyde concentration in residences and the development of a model for the prediction of its emission rates, Build. Environ., 147, 540–550, https://doi.org/10.1016/j.buildenv.2018.10.045, 2019.
Liang, W. and Yang, X.: Indoor formaldehyde in real buildings: Emission source identification, overall emission rate estimation, concentration increase and decay patterns, Build. Environ., 69, 114–120, https://doi.org/10.1016/j.buildenv.2013.08.009, 2013.
Liang, W., Gao, P., Guan, J., and Yang, X.: Modeling volatile organic compound (VOC) concentrations due to material emissions in a real residential unit. Part I: Methodology and a preliminary case study, Building Simulation, 5, 351–357, https://doi.org/10.1007/s12273-012-0083-6, 2012.
Lopez-Coto, I., Ren, X., Salmon, O. E., Karion, A., Shepson, P. B., Dickerson, R. R., Stein, A., Prasad, K., and Whetstone, J. R.: Wintertime CO2, CH4, and CO Emissions Estimation for the Washington, DC–Baltimore Metropolitan Area Using an Inverse Modeling Technique, Environ. Sci. Technol., 54, 2606–2614, https://doi.org/10.1021/acs.est.9b06619, 2020.
Mar, K. A., Unger, C., Walderdorff, L., and Butler, T.: Beyond CO2 equivalence: The impacts of methane on climate, ecosystems, and health, Environ. Sci. Pol., 134, 127–136, https://doi.org/10.1016/j.envsci.2022.03.027, 2022.
Merrin, Z. and Francisco, P. W.: Unburned Methane Emissions from Residential Natural Gas Appliances, Environ. Sci. Technol., 53, 5473–5482, https://doi.org/10.1021/acs.est.8b05323, 2019.
Mølhave, L., Sparks, L. E., Wolkoff, P., Clausen, P. A., Nielsen, P. A., and Bergsø, N. C.: The Danish Twin Apartment Study – Part II: Mathematical modeling of the relative strength of sources of indoor air pollution, Indoor Air, 6, 18–30, https://doi.org/10.1111/j.1600-0668.1996.t01-3-00003.x, 1996.
Nabinger, S. and Persily, A.: Airtightness, ventilation, and energy consumption in a manufactured house: pre-retrofit results, National Institute of Standards and Technology, Gaithersburg, MD, https://doi.org/10.6028/NIST.IR.7478, 2008.
Nabinger, S., Persily, A., and Dols, W.: Impacts of Airtightening Retrofits on Ventilation Rates and Energy Consumption in a Manufactured Home, Technical Note (NIST TN), National Institute of Standards and Technology, Gaithersburg, MD, 32 pp., https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=906322 (last access: 14 December 2024), 2010.
Nazaroff, W. W.: Residential air-change rates: A critical review, Indoor Air, 31, 282–313, https://doi.org/10.1111/ina.12785, 2021.
Nazaroff, W. W. and Cass, G. R.: Mathematical modeling of chemically reactive pollutants in indoor air, Environ. Sci. Technol., 20, 924–934, https://doi.org/10.1021/es00151a012, 1986.
Nicholas, D., Ackley, R., and Phillips, N. G.: A simple method to measure methane emissions from indoor gas leaks, PLOS ONE, 18, e0295055, https://doi.org/10.1371/journal.pone.0295055, 2023.
NOAA: 5-Minute Surface Weather Observations from the Automated Surface Observing Systems (ASOS) Network, Iowa State University [data set], https://mesonet.agron.iastate.edu/request/download.phtml?network=MD_ASOS (last access: 3 October 2024), 2024.
Offermann, F., and Hodgson, A.: Emission Rates of Volatile Organic Compounds in New Homes, Indoor Air, Austin, TX, https://www.researchgate.net/publication/312579181_Emission_Rates_of_Volatile_Organic_Compounds_in_New_Homes (last access: 14 December 2024) 2011.
Plant, G., Kort, E. A., Floerchinger, C., Gvakharia, A., Vimont, I., and Sweeney, C.: Large Fugitive Methane Emissions From Urban Centers Along the U.S. East Coast, Geophys. Res. Lett., 46, 8500-8507, https://doi.org/10.1029/2019GL082635, 2019.
Poppendieck, D. G., Ng, L. C., Persily, A. K., and Hodgson, A. T.: Long term air quality monitoring in a net-zero energy residence designed with low emitting interior products, Build. Environ., 94, 33–42, https://doi.org/10.1016/j.buildenv.2015.07.001, 2015.
Reichman, R., Shirazi, E., Colliver, D. G., and Pennell, K. G.: US residential building air exchange rates: new perspectives to improve decision making at vapor intrusion sites, Environ. Sci.-Proc. Imp., 19, 87–100, https://doi.org/10.1039/C6EM00504G, 2017.
Rella, C. W., Chen, H., Andrews, A. E., Filges, A., Gerbig, C., Hatakka, J., Karion, A., Miles, N. L., Richardson, S. J., Steinbacher, M., Sweeney, C., Wastine, B., and Zellweger, C.: High accuracy measurements of dry mole fractions of carbon dioxide and methane in humid air, Atmos. Meas. Tech., 6, 837–860, https://doi.org/10.5194/amt-6-837-2013, 2013.
Saint-Vincent, P. M. B. and Pekney, N. J.: Beyond-the-Meter: Unaccounted Sources of Methane Emissions in the Natural Gas Distribution Sector, Environ. Sci. Technol., 54, 39–49, https://doi.org/10.1021/acs.est.9b04657, 2020.
Sargent, M. R., Floerchinger, C., McKain, K., Budney, J., Gottlieb, E. W., Hutyra, L. R., Rudek, J., and Wofsy, S. C.: Majority of US urban natural gas emissions unaccounted for in inventories, P. Natl. Acad. Sci. USA, 118, e2105804118, https://doi.org/10.1073/pnas.2105804118, 2021.
US Census American Community Survey: Table DP04, Selected Housing Characteristics [data set], https://data.census.gov/table?q=DP04 (last access: 4 October 2024), 2023.
Yadav, V., Verhulst, K., Duren, R., Thorpe, A., Kim, J., Keeling, R., Weiss, R., Cusworth, D., Mountain, M., Miller, C., and Whetstone, J.: A declining trend of methane emissions in the Los Angeles basin from 2015 to 2020, Environ. Res. Lett., 18, 034004, https://doi.org/10.1088/1748-9326/acb6a9, 2023.
Zeng, Z.-C., Pongetti, T., Newman, S., Oda, T., Gurney, K., Palmer, P. I., Yung, Y. L., and Sander, S. P.: Decadal decrease in Los Angeles methane emissions is much smaller than bottom-up estimates, Nat. Commun., 14, 5353, https://doi.org/10.1038/s41467-023-40964-w, 2023.