<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-18-151-2025</article-id><title-group><article-title>Direct high-precision radon quantification for interpreting high-frequency greenhouse gas measurements</article-title><alt-title>Direct high-precision radon quantification​​​​​​​</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Kikaj</surname><given-names>Dafina</given-names></name>
          <email>dafina.kikaj@npl.co.uk</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Chung</surname><given-names>Edward</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-9445-5844</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Griffiths</surname><given-names>Alan D.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1135-1810</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Chambers</surname><given-names>Scott D.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-2521-959X</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3 aff4">
          <name><surname>Forster</surname><given-names>Grant</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1783-9307</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Wenger</surname><given-names>Angelina</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3 aff4">
          <name><surname>Pickers</surname><given-names>Penelope</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1923-5163</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Rennick</surname><given-names>Chris</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-4993-0156</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>O'Doherty</surname><given-names>Simon</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-4051-6760</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Pitt</surname><given-names>Joseph</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-8660-5136</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Stanley</surname><given-names>Kieran</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3388-0932</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff5">
          <name><surname>Young</surname><given-names>Dickon</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6723-3138</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3 aff8">
          <name><surname>Fleming</surname><given-names>Leigh S.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3114-8740</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Adcock</surname><given-names>Karina</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-8224-5399</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Safi</surname><given-names>Emmal</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff6 aff7">
          <name><surname>Arnold</surname><given-names>Tim</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9097-8907</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>National Physical Laboratory, Teddington, UK</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Australian Nuclear Science and Technology Organisation, Locked Bag 2001, Kirrawee DC NSW 2232, Australia</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Centre for Ocean and Atmospheric Sciences, School of Environmental Sciences, University of East Anglia, Norwich, UK</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>National Centre for Atmospheric Science, University of East Anglia, Norwich, UK</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>School of Chemistry, University of Bristol, Bristol, UK</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>School of GeoSciences, University of Edinburgh, Edinburgh, UK</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>Department of Physical Geography and Ecosystem Sciences, Lund University, Lund, Sweden</institution>
        </aff>
        <aff id="aff8"><label>a</label><institution>now at: GNS Science, Gracefield, Lower Hutt, 5040, New Zealand</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Dafina Kikaj (dafina.kikaj@npl.co.uk)</corresp></author-notes><pub-date><day>13</day><month>January</month><year>2025</year></pub-date>
      
      <volume>18</volume>
      <issue>1</issue>
      <fpage>151</fpage><lpage>175</lpage>
      <history>
        <date date-type="received"><day>29</day><month>March</month><year>2024</year></date>
           <date date-type="rev-request"><day>11</day><month>June</month><year>2024</year></date>
           <date date-type="rev-recd"><day>16</day><month>October</month><year>2024</year></date>
           <date date-type="accepted"><day>30</day><month>October</month><year>2024</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2025 Dafina Kikaj et al.</copyright-statement>
        <copyright-year>2025</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025.html">This article is available from https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d2e266">We present a protocol to improve confidence in reported radon activity concentrations, facilitating direct site-to-site comparisons and integration with co-located greenhouse gas (GHG) measurements within a network of three independently managed observatories in the UK. Translating spot measurements of atmospheric GHG amount fractions into regional flux estimates (“top-down” analysis) is usually performed with atmospheric transport models (ATMs), which calculate the sensitivity of regional emissions to changes in observed GHGs at a finite number of locations. However, the uncertainty of regional emissions is closely linked to ATM uncertainties. Radon, emitted naturally from the land surface, can be used as a tracer of atmospheric transport and mixing to independently evaluate the performance of such models. To accomplish this, the radon measurements need to have a comparable precision to the GHGs at the modelled temporal resolution. Australian Nuclear Science and Technology Organisation (ANSTO) dual-flow-loop two-filter radon detectors provide output every 30 min. The measurement accuracy at this temporal resolution depends on the characterization and removal of instrumental background, the calibration procedure, and response time correction. Consequently, unless these steps are standardized, measurement precision may differ between sites. Here we describe standardized approaches regarding (1) instrument maintenance, (2) quality control of the raw data stream, (3) determination and removal of the instrumental background, (4) calibration methods, and (5) response time correction (by deconvolution). Furthermore, we assign uncertainties for each reported 30 min radon estimate (assuming these steps have been followed) and validate the final result through comparison of diurnal and sub-diurnal radon characteristics with co-located GHG measurements. While derived for a network of UK observatories, the proposed standardized protocol could be equally applied to two-filter dual-flow-loop radon observations across larger networks, such as the Integrated Carbon Observation System (ICOS) or the Global Atmosphere Watch (GAW) baseline network.</p>
  </abstract>
    
<funding-group>
<award-group id="gs1">
<funding-source>Natural Environment Research Council</funding-source>
<award-id>NE/Y001788/1</award-id>
</award-group>
<award-group id="gs2">
<funding-source>UK Research and Innovation</funding-source>
<award-id>NE/R011532/1</award-id>
</award-group>
</funding-group>
</article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d2e278">The Paris Agreement aims to keep this century's mean global temperature rise well below 2 °C and pursue efforts to limit it to 1.5 °C above pre-industrial levels. Meeting this goal requires better understanding of greenhouse gas (GHG) emissions to enable the most efficient mitigation policies to be implemented. Current GHG emission information is dominated by “bottom-up” (prior) estimates derived from aggregated activity data, emission factors, and facility-level measurements (from local to country scale) that rely on reported data and knowledge of natural systems <xref ref-type="bibr" rid="bib1.bibx16 bib1.bibx35 bib1.bibx53" id="paren.1"><named-content content-type="pre">e.g.</named-content></xref>. Since there can be large uncertainties associated with the spatial and temporal variability of these emission factors across sectors, as well as potential biases from sources that are unaccounted for, especially for non-CO<sub>2</sub> GHGs, it is prudent to seek independent verification of the resulting emission estimates. To this end, a distributed network of precise, high-frequency, in situ GHG observations can provide opportunities for independent “top-down” verification of GHG emissions estimate.</p>
      <p id="d2e295">In recent decades many GHG monitoring stations have been developed throughout Europe. The Integrated Carbon Observation System (ICOS) (<uri>https://www.icos-cp.eu/</uri>, last access: 24 March 2024) constitutes Europe's primary research infrastructure for standardized, traceable, high-precision observations of atmospheric GHG amount fractions. This atmospheric monitoring network includes 46 stations across 16 European countries <xref ref-type="bibr" rid="bib1.bibx79 bib1.bibx80" id="paren.2"/> (<uri>https://www.icos-cp.eu/observations/atmosphere/stations</uri>, last access: 25 March 2024). The corresponding UK GHG network is UK DECC (UK Deriving Emissions related to Climate Change), consisting of five stations (Fig. <xref ref-type="fig" rid="Ch1.F1"/>): Mace Head (MHD), a World Meteorological Organization (WMO) Global Atmosphere Watch (GAW) baseline station, Tacolneston (TAC), Ridge Hill (RGL), Bilsdale (BSD), and Heathfield (HFD), each of which having at least one inlet 90 m or more above ground level (a.g.l.) <xref ref-type="bibr" rid="bib1.bibx61 bib1.bibx62" id="paren.3"/>.</p>

      <fig id="Ch1.F1"><label>Figure 1</label><caption><p id="d2e314">Geographical position of UK DECC stations measuring radon activity concentration (TAC, HFD, RGL, and MHD), along with affiliated WAO – an ICOS site. Note that measurements from MHD and RGL, highlighted in grey, are not considered in this study.</p></caption>
        <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f01.png"/>

      </fig>

      <p id="d2e324">The most commonly used top-down method for making GHG emission estimates is through the use of inverse modelling, where high-quality GHG measurements are combined with atmospheric transport models (ATMs) and prior information to make optimal emission estimates <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx5 bib1.bibx6 bib1.bibx8 bib1.bibx25 bib1.bibx48 bib1.bibx50 bib1.bibx51" id="paren.4"/>. Another method is the radon tracer method (RTM), which utilizes simultaneous, co-located observations of <sup>222</sup>Rn (hereafter radon) and a GHG, in combination with an estimated radon source function. Different implementations of this approach allow either local- or regional-scale GHG emission estimates to be made from the same fetch region influencing the radon observations <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx33 bib1.bibx38 bib1.bibx44 bib1.bibx46 bib1.bibx69 bib1.bibx70 bib1.bibx71" id="paren.5"><named-content content-type="pre">e.g.</named-content></xref>.</p>
      <p id="d2e344">Despite recent improvements in the spatio-temporal density of observations and the excellent quality of GHG measurements (relative uncertainties often <inline-formula><mml:math id="M3" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 0.1 %), as well as the mathematical elegance of ATMs <xref ref-type="bibr" rid="bib1.bibx4 bib1.bibx18 bib1.bibx67 bib1.bibx82" id="paren.6"><named-content content-type="pre">e.g.</named-content></xref>, large uncertainties remain in total annual top-down GHG emission estimates (e.g. <inline-formula><mml:math id="M4" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 10 %  for the UK N<sub>2</sub>O emission estimate; UK's National Inventory Report to the United Nations Framework Convection on Climate Change 2022). A key contributor to the overall uncertainty in top-down inverse model estimates of GHG emissions is the ATMs themselves. The challenge of quantifying ATM uncertainty is evident in tasks such as boundary layer height estimation and parameterization of meteorological variables, where errors are related to the resolution of the model <xref ref-type="bibr" rid="bib1.bibx26 bib1.bibx27 bib1.bibx47 bib1.bibx52 bib1.bibx67" id="paren.7"><named-content content-type="pre">e.g.</named-content></xref>. As yet, no optimal method exists to evaluate the discrepancies between a priori and a posteriori emission estimates (bias). Until it is possible to accurately quantify an ATM's uncertainty, full realization of the potential offered by high-quality atmospheric measurements from a comprehensive tower network cannot be achieved. This is a crucial step for improving national inventories and developing policy that the international community should have while strengthening the 2015 Paris Agreement.</p>
      <p id="d2e380">To this end, measurements of the naturally occurring, passive tracer radon could provide a means of evaluating ATM performance. Moreover, subject to the measurement location and sampling height, among other things, radon observations can be a valuable tool for atmospheric baseline monitoring <xref ref-type="bibr" rid="bib1.bibx11" id="paren.8"><named-content content-type="pre">e.g.</named-content></xref>, evaluating the performance of regional or global chemical transport models <xref ref-type="bibr" rid="bib1.bibx12 bib1.bibx82" id="paren.9"><named-content content-type="pre">e.g.</named-content></xref>, or characterizing the atmospheric mixing state <xref ref-type="bibr" rid="bib1.bibx13 bib1.bibx42 bib1.bibx57 bib1.bibx75" id="paren.10"/>. Consequently, efforts to broaden the international radon monitoring network and harmonize the resulting measurements not only stand to improve GHG emissions estimate via atmospheric inversion studies, but also provide a second independent top-down method to estimate local- to regional-scale GHG emissions via the RTM, as well as other research opportunities.</p>
      <p id="d2e396">Radon is the gaseous decay product of <sup>226</sup>Ra (radium), a member of the <sup>238</sup>U (uranium) decay chain, which is ubiquitous all over the Earth's crust. When emitted into the atmosphere, radon experiences the same atmospheric transport and mixing as all other gases released near the surface. Being an inert gas, radon (<sup>222</sup>Rn) does not chemically react with any atmospheric constituents, and its low solubility makes it resistant to dry and wet deposition, leaving radioactive decay (half-life of 3.82 d) as its sole atmospheric sink.  Its half-life, conveniently between the timescales of diurnal and synoptic atmospheric processes, is ideal for characterizing a wide range of meteorological phenomena <xref ref-type="bibr" rid="bib1.bibx24 bib1.bibx41 bib1.bibx74 bib1.bibx81" id="paren.11"/>. It is therefore considered a powerful and convenient tracer at mesoscale, synoptic scales, and global scales for improving, testing, and validating atmospheric models <xref ref-type="bibr" rid="bib1.bibx10 bib1.bibx13 bib1.bibx39 bib1.bibx40 bib1.bibx64 bib1.bibx82" id="paren.12"/>.</p>
      <p id="d2e432">Since its discovery in 1900, radon's unique physical characteristics have  led to its use in studies of vertical mixing and air mass history <xref ref-type="bibr" rid="bib1.bibx19 bib1.bibx73 bib1.bibx77" id="paren.13"/>. Early studies employed a variety of discrete measurement techniques but were often lacking in sensitivity or temporal resolution. The most significant progress in utilizing radon as a relative tracer for vertical mixing and transport near the Earth's surface has been achieved since the 1960s, mainly driven by advancements in continuous measurement techniques. Initially, public health (indoor) applications dominated instrument development, but the large indoor-to-outdoor gradient in radon activity concentrations (henceforth radon concentrations) limited the utility of these instruments in the outdoor environmental atmosphere. The first semi-continuous radon detector was developed in the mid-1960s <xref ref-type="bibr" rid="bib1.bibx65" id="paren.14"/>. While suitable for near-surface inland measurements, this type of detector was not sufficiently sensitive for measurements at coastal or island sites. The capability to measure radon concentrations typical of the remote marine atmosphere began to emerge post-1970 <xref ref-type="bibr" rid="bib1.bibx43 bib1.bibx58 bib1.bibx56 bib1.bibx44" id="paren.15"/>. More recently still, refinement of the original two-filter radon detector <xref ref-type="bibr" rid="bib1.bibx66" id="paren.16"/> by <xref ref-type="bibr" rid="bib1.bibx72" id="text.17"/> greatly improved both the sensitivity and temporal resolution of radon measurements, better aligning them with advances in GHG measurements and modelling resolution. This growing collection of one- and two-filter radon monitors constituted the first of the “research-grade” instruments. Following these developments, the popularity of radon increased as a quantitative tracer in atmospheric modelling <xref ref-type="bibr" rid="bib1.bibx15 bib1.bibx18 bib1.bibx40 bib1.bibx37 bib1.bibx49 bib1.bibx81 bib1.bibx82" id="paren.18"/> and estimation of GHG fluxes on the local to regional scale by the RTM <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx33 bib1.bibx44 bib1.bibx46 bib1.bibx68 bib1.bibx69" id="paren.19"/>.</p>
      <p id="d2e457">Contemporary research-grade radon monitors are based on three fundamentally different measurement techniques: (i) indirect one-filter <inline-formula><mml:math id="M9" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>- or <inline-formula><mml:math id="M10" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>- activity detectors, which directly filter ambient aerosol-bound radon progeny from the atmosphere and count them, assuming equilibrium between atmospheric radon and its progeny <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx45 bib1.bibx44 bib1.bibx58" id="paren.20"/>; (ii) direct two-filter detectors that first remove ambient radon progeny, before filtering out and counting new unattached radon progeny formed inside a large measurement volume under controlled conditions <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx31 bib1.bibx72" id="paren.21"/>; and (iii) direct electrostatic deposition monitors, which also remove ambient progeny and allow new progeny to form inside a small measurement volume but deposit these progeny electrostatically on a detector <xref ref-type="bibr" rid="bib1.bibx32 bib1.bibx56 bib1.bibx71" id="paren.22"/>.</p>
      <p id="d2e484">Continuous, long-term atmospheric radon measurements are currently performed worldwide using the three principles of measurement mentioned above. Maximizing the value and utility of such large datasets across a range of applications requires a traceability chain for calibrations and standardized data processing techniques appropriate to each type of detector. Although there have already been some efforts to compare and harmonize radon measurements across the existing eclectic global network <xref ref-type="bibr" rid="bib1.bibx34 bib1.bibx78 bib1.bibx60" id="paren.23"/>, more attention needs to be given to preparation of a standardized protocol for retrieving the highest-quality, most directly comparable atmospheric radon datasets from each kind of contributing instrument. Due to the distinct measurement principles of each instrument, tailored approaches are necessary to maximize consistency and comparability of datasets. For instance, indirect one-filter detectors require corrections for tube loss, equilibrium (for inlets below 80–100 m a.g.l.), and exclusion of foggy/rainy conditions. While two-filter detectors are highly sensitive and independent of tube length, measurement height, or weather conditions, the larger models (700 and 1500 L) can have a 4 %–8 % uncertainty in individual field calibrations (unless a transfer standard is used) and require response time correction. Meanwhile, electrostatic deposition monitors need to dry their sample air (and/or correct for water vapour) and remove or correct for thoron (<sup>220</sup>Rn). Therefore, to maximize consistency and comparability across various instruments, it is essential to establish a standardized processing procedure for each instrument type. This instrument-specific standardized procedure should be applicable to any atmospheric station measuring radon concentration with that type of instrument and would enable optimal utilization of radon measurements by the atmospheric composition research community, particularly in studies verifying GHG emission estimates.</p>
      <p id="d2e499">To this end, here we present a new protocol for processing measurements made by the fastest (30 min temporal resolution), most sensitive (detection limit <inline-formula><mml:math id="M12" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 0.025 Bq m<sup>−3</sup>), and most widely used radon detectors within global and European atmospheric monitoring networks – the 1500 L “two-filter dual flow-loop” detector, developed by the Australian Nuclear Science and Technology Organisation (ANSTO). In the last 28 years, 50 two-filter radon detectors have been part of campaigns or have been integrated within global and European atmospheric monitoring networks (39 of which are still operational), 11 (4) of which are part of the ICOS (UK DECC) network. Compared to indirect detectors, two-filter detectors provide a measure of radon concentration that is independent of height above ground, distance from land, meteorological conditions (e.g. fog/rain), fetch conditions, ambient aerosol loading, and length or type of sampling tube. Consequently, their calibration traceability is more readily achievable under a wide range of measurement conditions <xref ref-type="bibr" rid="bib1.bibx14" id="paren.24"/>.</p>
      <p id="d2e524">This study utilizes 1 year (September 2020–August 2021) of radon measurements by 1500 L two-filter detectors at the three UK sites with contrasting sample inlet heights: TAC, HFD (UK DECC sites), and Weybourne Atmospheric Observatory (WAO, a UK ICOS and affiliated DECC site). The specific objectives are to (i) outline the expected maintenance protocol for these detectors, (ii) outline a proposed standard processing protocol for near-real-time data use, including calibration, response time correction <xref ref-type="bibr" rid="bib1.bibx31" id="paren.25"/>, standard temperature and pressure (STP) correction, and, optionally, correcting output to dry-air amount fractions; (iii) validate the timing of response-time-corrected radon concentrations using well-defined calibration events; and (iv) assess the precision of the resulting radon signal by comparing it with high-resolution GHG (CO<sub>2</sub>, CH<sub>4</sub>, and N<sub>2</sub>O) amount fraction measurements aggregated to 60 min values.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Measurement sites and instrumentation</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Measurement sites</title>
      <p id="d2e572">This study focuses on atmospheric radon concentration and GHG (CO<sub>2</sub>, CH<sub>4</sub>, and N<sub>2</sub>O) amount fraction measurements made at three sites of the UK DECC network with contrasting inlet heights (TAC, HFD, and WAO; Fig. <xref ref-type="fig" rid="Ch1.F1"/>). Measurements at RGL (51.998° N, 2.540° W) were excluded due to the limited calibration and background measurement history within this study's time frame. Measurements at MHD were also excluded since radon concentrations at this station are conducted with a one-filter detector <xref ref-type="bibr" rid="bib1.bibx7" id="paren.26"/>. Each station in the UK DECC network measures at least CO<sub>2</sub>, CH<sub>4</sub>, N<sub>2</sub>O, and sulfur hexafluoride (SF<sub>6</sub>). However, some also measure carbon monoxide (CO), stable isotopic ratios (<inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">δ</mml:mi><mml:mn mathvariant="normal">13</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>C(CH<sub>4</sub>), <inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">δ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>H(CH<sub>4</sub>)), radiocarbon in atmospheric CO<sub>2</sub> (<inline-formula><mml:math id="M29" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula><sup>14</sup>CO<sub>2</sub>), and the oxygen <inline-formula><mml:math id="M32" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> nitrogen (O<sub>2</sub> <inline-formula><mml:math id="M34" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> N<sub>2</sub>) ratio.</p>
      <p id="d2e751">For the results here, measurements of radon concentration, CO<sub>2</sub>, CH<sub>4</sub>, and N<sub>2</sub>O amount fractions have been aggregated to hourly temporal resolution and reported in local solar time (LST; equivalent to Universal Time Coordinated (UTC) in these locations). The Northern Hemisphere seasonal convention has been adopted (i.e. autumn: September–November; winter: December–February; spring: March–May; summer: June–August).</p>
<sec id="Ch1.S2.SS1.SSS1">
  <label>2.1.1</label><title>Tacolneston (TAC)</title>
      <p id="d2e788">The TAC tall tower (52.518° N, 1.139° E; 56 m above sea level – a.s.l.) is situated southwest of Norwich, 28 km east of Thetford, Norfolk. Sampling inlets are arranged at three heights: 54, 100, and 185 m a.g.l. Since 2012, measurements of CO<sub>2</sub>, CH<sub>4</sub>, N<sub>2</sub>O, CO, and SF<sub>6</sub> amount fractions have been taken at all heights. In 2020, radon concentration started being sampled from 175 m a.g.l. Additional technical details regarding the tower setup can be accessed in <xref ref-type="bibr" rid="bib1.bibx61" id="text.27"/>. As well as being part of the UK DECC network, TAC is part of the Advanced Global Atmospheric Gases and Experiment (AGAGE) network and is a WMO GAW regional site.</p>
</sec>
<sec id="Ch1.S2.SS1.SSS2">
  <label>2.1.2</label><title>Heathfield (HFD)</title>
      <p id="d2e838">The HFD tall tower (50.977° N, 0.231° E; 157 m a.s.l.) is situated in southeast England, 20 km from the coast, surrounded by woodland and agricultural green space. Measurements at this site are being conducted from an existing telecommunication tower. Sampling began in January 2014, and measurements of key GHGs (CO<sub>2</sub>, CH<sub>4</sub>, N<sub>2</sub>O, and SF<sub>6</sub>) are being made from two sampling inlet heights (50 and 100 m a.g.l). Atmospheric radon measurements were introduced in 2020, with an independent inlet at 100 m a.g.l. Further information on technical details of the tower setup can be found in <xref ref-type="bibr" rid="bib1.bibx62" id="text.28"/>.</p>
      <p id="d2e880">HFD is a part of the UK DECC network and is also a WMO GAW regional site. HFD is considered to be a background site of the UK DECC network as the predominant southwesterlies experience little land fetch prior to reaching HFD from the Atlantic Ocean (see Fig. <xref ref-type="fig" rid="Ch1.F1"/>). However, it can also experience high-pollution events since it is relatively close to the conurbation Royal Tunbridge Wells (17 km north-northeast), greater London (40 km north-northeast), and continental Europe (southwest).</p>
</sec>
<sec id="Ch1.S2.SS1.SSS3">
  <label>2.1.3</label><title>Weybourne Atmospheric Observatory (WAO)</title>
      <p id="d2e894">The WAO (52.951° N, 1.122° E; 17 m a.s.l.) is situated on the northern Norfolk coast, approximately 35 km north-northwest of Norwich, 170 km northeast of London, and 200 km east of Birmingham. WAO is an ICOS site, a regional WMO GAW site, and also an affiliated UK DECC site. WAO was established in 1992 <xref ref-type="bibr" rid="bib1.bibx55" id="paren.29"/>, and a wide array of atmospheric gas species (GHG amount fractions, stable isotopic ratio, reactive gases, as well as radon since March 2018) are measured there from a sampling inlet at 10 m a.g.l. Due to its location, WAO receives a variety of air masses from a range of sources including well-mixed background air (Atlantic, Arctic, North Sea) and polluted air (European, UK) <xref ref-type="bibr" rid="bib1.bibx1 bib1.bibx20 bib1.bibx22" id="paren.30"/>.</p>
</sec>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Radon instrument: 1500 L dual-flow-loop two-filter</title>
<sec id="Ch1.S2.SS2.SSS1">
  <label>2.2.1</label><title>Operating principle</title>
      <p id="d2e920">Atmospheric radon concentration is measured at all three sites (HFD, TAC, and WAO) using 1500 L dual-flow-loop two-filter radon detectors, designed and built by ANSTO, which provide half-hourly, high accurately and precision measurements. The principle of operation is described in detail elsewhere <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx31 bib1.bibx66 bib1.bibx72" id="paren.31"/> and is only summarized here. The detector relies on gross <inline-formula><mml:math id="M47" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> counting, making the signal sensitive to other radon isotopes (e.g. <sup>220</sup>Rn, half-life of 55.6 s; actinon: <sup>219</sup>Rn, half-life of 4 s) as well. To eliminate contributions from unwanted radon isotopes (of which the longest-lived is <sup>220</sup>Rn), this system includes a “thoron delay volume” prior to the first filter, which acts to delay the sampled air for <inline-formula><mml:math id="M51" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 min, allowing time for all unwanted radon isotopes to decay to their aerosol progeny. Following this, the sampled air is filtered (by the “primary filter”) to remove the progeny of all radon isotopes and any ambient aerosols before it passes through to the main delay chamber, where a portion of the sampled ambient <sup>222</sup>Rn decays under controlled conditions to produce unattached aerosol progeny. These new unattached progeny (particularly the short-lived <inline-formula><mml:math id="M53" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> emitters <sup>218</sup>Po and <sup>214</sup>Po) are then efficiently collected on a 20 <inline-formula><mml:math id="M56" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m stainless-steel mesh (the second filter). The instrument then reports the number of <inline-formula><mml:math id="M57" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> decays counted each 30 min using silver-activated zinc-sulfide (ZnS(Ag)) scintillation material coupled to a photomultiplier (referred to as the “measurement head”). Output from the photomultiplier is amplified and fed into a discriminator. Total counts above a threshold of 0.5 V are recorded as LLD (lower level of discrimination), and total counts above a threshold of 1.0 V are recorded as ULD (upper level of discrimination). It has been empirically determined that ULD counts essentially represent different forms of noise, so it is the number of counts that lie within the 0.5–1.0 V pulse-height window that are used to calculate the activity concentration of radon (in Bq m<sup>−3</sup>). The time stamp associated with a count represents the end of the measurement period.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS2">
  <label>2.2.2</label><title>Instrument maintenance</title>
      <p id="d2e1039">Although ANSTO two-filter radon monitors are designed to require minimal maintenance, a degree of periodic maintenance is required to minimize ongoing operational costs and ensure consistent optimal performance, a prerequisite for effectively harmonizing measurements across a network. Most crucial to ongoing performance is the detector's measurement head, which contains the second filter and a plastic sheet impregnated with ZnS(Ag) powder. These materials should be replenished every 5 years. The second filter will slowly accumulate lead (<sup>210</sup>Pb, half-life of 22.3 years) and cannot be cleaned. If the background becomes too high (e.g. <inline-formula><mml:math id="M60" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 8–10 counts min<sup>−1</sup>), then the detection limit will deteriorate. The integrity of the ZnS(Ag) powder will also deteriorate over time (faster in very humid environments) and progressively reduce the detector's sensitivity to radon (typically a change of 0.5 %–1.5 % yr<sup>−1</sup>). If the detector is in a high-vibration environment, there should be an annual check that the measurement head is still properly seated in the central pipe (following instructions in the detector's commissioning document). Likewise, if the detector is moved vigorously with the measurement head still inside, the seating of the head in the central pipe should be checked.</p>
      <p id="d2e1082">The next most important maintenance consideration is the detector's calibration system. If a pump is used to flush the radon source (rather than compressed gas), the stability of the delivery flow rate (0.10–0.15 L min<sup>−1</sup>) should be checked every 3–6 months or radon delivery during calibrations may become inconsistent. The desiccant tube attached to the calibration system inlet should be checked and refilled every 3 months to maintain consistent humidity levels. Fluctuations in humidity within the source capsule could potentially affect the radon emanation rate. Conversely, compressed-gas calibration systems only require a replacement of the gas bottle for maintenance very 2 years.</p>
      <p id="d2e1097">To protect the radon detector's sampling pump and extend the life of the primary filter, it is essential to prevent dust from passing too far through the sampling line. Typically, an easily accessible and cost-effective coarse aerosol filter is installed upstream of the pump. Depending on the expected aerosol loading at each site, this pre-filter should be inspected and/or replaced every 6–12 months.</p>
      <p id="d2e1100">The detector should be checked for leaks annually, with the leak rate not exceeding 2 L min<sup>−1</sup>. To prevent near-surface radon-rich air from entering the detection volume due to potential small leaks, it is crucial to maintain an operating overpressure of the detector's main (1500 L) delay volume between 1–2 hPa. Note that if a long exhaust line is fitted to the detector the associated flow impedance may increase the overpressure to between 2–3 hPa. The inlet line (from the base of the sampling tower to the inlet of the detector) should also be checked for leaks annually.</p>
      <p id="d2e1116">The internal clock of the detector's data logger should be synchronized to the networked operating computer quarterly and the logger's internal battery replaced every 5 years. All moving parts of the detector should be replaced every 10 years to avoid mechanical failure, and all electrical components (particularly power supplies) should be replaced every 10 years to prevent electrical noise from developing.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS3">
  <label>2.2.3</label><title>Instrument calibration</title>
      <p id="d2e1127">ANSTO two-filter detectors are too large to be moved periodically and traceably calibrated in a controlled climate chamber, and their high sampling rate (90 L min<sup>−1</sup>) makes it financially and logistically impractical to attempt regular, traceable calibrations directly in situ (which would require a 90 L min<sup>−1</sup> flow of radon-free air for around 8 h, either through a filtration system or a large bank of gas cylinders). The ideal calibration approach would be to transfer a traceable calibration to the operating detector using a mobile calibration transfer device <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx59" id="paren.32"/>. While few such devices are currently available, inquiries about obtaining one can be sent to radon@ansto.gov.au. The compromise usually adopted is to conduct approximate in situ calibrations using a portable radon source while the instrument continues to sample ambient air. The procedure for a single calibration event is described below.</p>
      <p id="d2e1157">All ANSTO two-filter radon detectors in this study are calibrated using passive Pylon 2000A <sup>226</sup>Ra sources <inline-formula><mml:math id="M68" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 49 kBq (Pylon Electronics, <uri>https://pylonelectronics-radon.com/radioactive-sources/</uri>, last access: 24 March 2024; the source strength at each site is reported in Table <xref ref-type="table" rid="App1.Ch1.S1.T3"/>). The timing of calibrations, duration of calibrations, and source flushing times are all user-defined and can slightly change from site to site.</p>
      <p id="d2e1181">Prior to initiating a calibration, the <sup>226</sup>Ra source should be well-flushed, with the exhaust directed to the outside ambient air at a point well removed from the detector sampling location. The optimal flushing time for each calibration setup is assessed by the shape of the calibration curve. The curve should rise monotonically to a near-constant concentration after <inline-formula><mml:math id="M70" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 5 h. If the curve rises steeply, overshoots, and then begins to decrease again, the source was not sufficiently flushed. The flushing time should be determined empirically for each installation and will depend on factors such as the source strength, the flushing flow rate, and the time since the source was last flushed. The flushing flow rate is usually lower (0.08–0.15 L min<sup>−1</sup>) if the source is being flushed with ambient air (to minimize the amount of ambient <sup>222</sup>Rn and <sup>220</sup>Rn introduced to the system) but can be higher (0.15–0.25 L min<sup>−1</sup>) if being flushed with dry, radon-free air (to improve the consistency of radon delivery). A flushing period between 5–10 h is usually sufficient. Once the initial flushing is complete, a calibration is then performed by continuing to pass air through the source, but this time directed into the detector's sampling airstream, for a period of 5 h while the detector continues to operate normally (see Fig. <xref ref-type="fig" rid="Ch1.F2"/>). After injection finishes, it can take up to 6 h for the radon concentration inside the detector to return to ambient values.</p>

      <fig id="Ch1.F2"><label>Figure 2</label><caption><p id="d2e1248">Example calibration peak resulting from a 5 h injection and net calibration peak magnitude derived from linearly estimated ambient radon concentration at the time of peak counts.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f02.png"/>

          </fig>

      <p id="d2e1257">Once the calibration injection has been performed the calibration coefficient, <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi mathvariant="normal">cal</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (counts s<sup>−1</sup> (Bq m<sup>−3</sup>)<sup>−1</sup>), is calculated through the following equation:
              <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M79" display="block"><mml:mrow><mml:msub><mml:mi>c</mml:mi><mml:mi mathvariant="normal">cal</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced close=")" open="("><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">peak</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mrow><mml:mi mathvariant="normal">peak</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">a</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow><mml:mn mathvariant="normal">1800</mml:mn></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">ex</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">source</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mi>s</mml:mi><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">peak</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the count recorded at the 5 h injection, <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mrow><mml:mi mathvariant="normal">peak</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">a</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the estimated ambient count (at the 5 h peak counts), <inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">ex</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (m<sup>3</sup> s<sup>−1</sup>) is the sampling flow rate, <inline-formula><mml:math id="M85" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">source</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (Bq s<sup>−1</sup>) is the radon delivery rate of the <sup>226</sup>Ra calibration source, and <inline-formula><mml:math id="M88" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> is a dimensionless scaling factor.</p>
      <p id="d2e1466">The scaling factor is required to account for the fact that after only 5 h of injection from the source, the radon concentration within the detector will not have completely come to equilibrium due to its logarithmic growth curve. Based on a model of the detector response <xref ref-type="bibr" rid="bib1.bibx31" id="paren.33"/> after 5 h of injection into a 1500 L radon detector sampling at 90 L min<sup>−1</sup> the concentration of radon inside the detector will have reached <inline-formula><mml:math id="M90" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 99.3 % of the equilibrium value. This leads to scaling factor of 1.007 (reciprocal of <inline-formula><mml:math id="M91" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 99.3) for a 1500 L detector. A Python notebook has been written which provides an analytical solution to the model equations and can be used to calculate the scaling factor  <xref ref-type="bibr" rid="bib1.bibx28" id="paren.34"/>​​​​​​​.</p>
      <p id="d2e1501">Assuming that the calibration unit is functioning reliably, the largest source of uncertainty in the field calibration process is in the estimation of <inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mrow><mml:mi mathvariant="normal">peak</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">a</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>. Typically, an assumption is made that ambient radon concentrations change little, and linearly, over the duration of the calibration event (10–11 h; yellow line, Fig. <xref ref-type="fig" rid="Ch1.F2"/>). However, the accuracy of this assumption is influenced by many factors, including timing of the calibration injection within a diurnal cycle, ambient wind speed during the calibration event, air mass fetch conditions, and day length <xref ref-type="bibr" rid="bib1.bibx14" id="paren.35"><named-content content-type="pre">see Fig. 7a in</named-content></xref>. Consequently, at flat inland sites calibrations are best performed during windy conditions and the source injection should be timed to finish around 13:00–14:00 LST, when the boundary layer is deepest and most well-mixed. For coastal or island sites calibrations are best performed under windy conditions with oceanic fetch. Under oceanic fetch conditions the calibration injection duration can be increased to 6 h to reduce the magnitude of the required scaling factor, <inline-formula><mml:math id="M93" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula>. At high mountain sites calibrations are best conducted at night under katabatic flow conditions. Calibrations can be initiated remotely during suitable conditions, or they can be set on a regular schedule, and events occurring during non-ideal conditions can be excluded.</p>
      <p id="d2e1534">To minimize relative uncertainty introduced by the <inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mrow><mml:mi mathvariant="normal">peak</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">a</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> estimation process, the detectors are usually calibrated at a radon concentration that is at least an order of magnitude greater than the expected annual maximum ambient radon concentration at the site. Despite being calibrated at relatively high radon concentrations, the resulting calibrations have been proven to be quite linear down to very low radon concentrations <xref ref-type="bibr" rid="bib1.bibx59" id="paren.36"/>.</p>
      <p id="d2e1556">To this end, consistent, application-specific calibration approaches need to be agreed upon and formalized (a key goal of this study) rather than users at different sites simply applying each monthly calibration coefficient. As previously mentioned, if a calibration transfer device is available <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx59" id="paren.37"/> then a traceable calibration can be transferred to an operating 1500 L detector in situ, over a period of around 2 weeks, without the need for approximate monthly calibrations. In this case, it would only be necessary to calibrate the detector once per year to characterize the slow change in sensitivity over the 5-year period until the measurement head is refreshed. If one portable calibration transfer device was allocated to a network of five 1500 L two-filter radon detectors, the cost would be less than buying individual calibration devices for the five large detectors.</p>
      <p id="d2e1563">In the absence of a calibration transfer device, the next most accurate calibration approach (as described in <xref ref-type="bibr" rid="bib1.bibx14" id="altparen.38"/>) is to develop a linear calibration model for the 5-year period between detector head replacements, since the gradual degradation of the ZnS(Ag) scintillation material is the primary cause of changing detector sensitivity. However, this calibration method can only be applied retrospectively. While the level of calibration accuracy provided by this approach is necessary for deriving consistent vertical radon gradient measurements from tall towers, an alternative calibration approach (with a slightly increased uncertainty) is necessary if the observed radon concentrations need to be used in near-real time (described in Sect. 3.2 and 3.3). Regarding gradient measurements, during the day, when mixing in the atmospheric boundary layer is strongest, radon gradients over the lowest 50 to 100 m of the atmosphere can be as low as 0.1–0.2 Bq m<sup>−3</sup>  <xref ref-type="bibr" rid="bib1.bibx9" id="paren.39"><named-content content-type="pre">e.g.</named-content></xref>. The response time of two-filter radon detectors is too slow for a single detector to be multiplexed for multi-height (gradient or profile) measurements. This means that separate (independently calibrated) detectors are required to measure concentrations at each height. Since daytime radon concentrations over land in the surface layer are typically 1–3 Bq m<sup>−3</sup> and the measurement uncertainty of ANSTO 1500 L detectors is <inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mo>∼</mml:mo></mml:mrow></mml:math></inline-formula> 10 % for radon concentration <xref ref-type="bibr" rid="bib1.bibx34" id="paren.40"><named-content content-type="pre">see</named-content></xref>, it is usually possible to reliably determine such gradients when detectors are appropriated calibrated.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS4">
  <label>2.2.4</label><title>Instrumental background</title>
      <p id="d2e1623">The instrumental background, LLD<sub>bg</sub> (counts per 30 min), of ANSTO two-filter detectors arises from various contributing factors, such as (i) cosmic radiation; (ii) natural radioactivity of surrounding rocks, soils, or building materials; (iii) accumulation of <sup>210</sup>Pb as well as the intrinsic background count rate of the photomultiplier caused by other effects (e.g. photons; <xref ref-type="bibr" rid="bib1.bibx76" id="altparen.41"/>) on the detector's second filter; and (iv) self-generation of radon (by trace amounts of <sup>226</sup>Ra in the detector building materials). The first two factors are small, site-specific, and relatively constant. <sup>210</sup>Pb accumulation gives rise to an increasing <inline-formula><mml:math id="M102" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> count (due to subsequent <sup>210</sup>Po decay). Self-generation of radon inside a detector is also constant (due to the 1600-year half-life of <sup>226</sup>Ra) and typically small, and it varies from build to build of each detector. Considered over multiple years, the detector's background count increases approximately linearly.</p>
      <p id="d2e1691">Ideally, the background should be determined while the detector is operating normally, sampling radon-free air at 90 L min<sup>−1</sup> for a period of at least 10–12 h. However, the necessary supply of radon-free air for regular tests of this kind is logistically and financially impractical. The compromise for field LLD<sub>bg</sub> is to simply shut the sampling system down for a 24 h period. It is advised to conduct these checks every 2 to 3 months. Background measurements are conducted by deactivating blowers in both the external and internal flow loops, as well as closing the detector's inlet solenoid valve for 24 h. This process is divided into three stages. <list list-type="order"><list-item>
      <p id="d2e1717"><italic>Decay (5.5 h)</italic>. This 5.5 h period marks the decay of the short-lived radon progeny on the detector's second filter below detection limits within 5–6 h of the detector shutdown.</p></list-item><list-item>
      <p id="d2e1723"><italic>Background (18.5 h)</italic>. The count reading stabilizes (with a degree of uncertainty) to a constant background level.</p></list-item><list-item>
      <p id="d2e1729"><italic>Recovery (1–2 h)</italic>. Upon reactivating the blowers and opening the detector's inlet solenoid valve, the instrument undergoes several 30 min measurement cycles (1–2 h) to readjust itself and return to the ambient levels.</p></list-item></list></p>
      <p id="d2e1734">During a background check the detector's inlet is blocked to prevent flow through the detector arising from Venturi effects across the inlet line (near the top of the sampling tower). However, the detector's exhaust valve is left open, making it possible for back diffusion of radon to occur into the detector. This is usually only a concern at sites where nocturnal radon concentrations at the detector's location are high. Closing both the inlet and exhaust valves of the detector during a background measurement is not advisable unless the detector is in a temperature-controlled environment or equipped with a pressure relief mechanism. Diurnal temperature variations could lead to pressure fluctuations within the detector, potentially causing leaks. The inlet valve is closed in preference to the exhaust valve during a background check to prevent overpressuring the detector if the powerful external flow loop blower is accidentally restarted before the exhaust valve is opened.</p>
      <p id="d2e1737">If the 18 h background data in step 2 above are observed to gradually decrease, rather than being approximately constant, <sup>220</sup>Rn contamination of the second filter (in the measurement head) is likely. This is indicative of a leak (e.g. in the sampling line or the detector) or an accumulation of <sup>224</sup>Ra-containing dust in the detector's thoron delay volume.</p>
</sec>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Greenhouse gas (GHG) instruments</title>
      <p id="d2e1767">At HFD, continuous, high-frequency (0.2 Hz) CO<sub>2</sub> and CH<sub>4</sub> measurements are made using a G2401 cavity ring-down spectrometer (CRDS; Picarro Inc., USA), while (0.4 Hz) N<sub>2</sub>O measurements are made using G5310 CRDS. At TAC, (0.3 Hz) CO<sub>2</sub> and CH<sub>4</sub> measurements are made using a G2301 CRDS, while (1 Hz) N<sub>2</sub>O measurements are made using an off-axis integrated cavity output spectrometer (OA-ICOS; Los Gatos Research Inc., USA). Sampling occurs alternately at different inlet heights along the tower, resulting in measurements from various heights not being simultaneous. For instance, at HFD air is sampled for about 20 min at 50 m a.g.l., followed by another 40 min of sampling at 100 m a.g.l. with a minute of flushing in between to avoid contributions from the previous level. To address this height switching during sampling, measurements are linearly interpolated to create a continuous hourly time series instead of straightforwardly averaging over an hour. Data are corrected for daily linear instrumental drift using standard gases (natural composition) and for instrumental non-linearity using calibration gases (natural composition). Further information on instrumentation, including flow diagrams, measurement protocol, calibration of standards, and uncertainty estimation, can be found in <xref ref-type="bibr" rid="bib1.bibx61" id="text.42"/> and <xref ref-type="bibr" rid="bib1.bibx62" id="text.43"/>.</p>
      <p id="d2e1831">At WAO, 1 min measurements of CH<sub>4</sub> and N<sub>2</sub>O are made using a commercial Fourier transform infrared spectrometer (FTIR) instrument (ACOEM Spectronus™): a detailed description of the FTIR can be found in <xref ref-type="bibr" rid="bib1.bibx36" id="text.44"/>. The instrument is routinely calibrated with gases provided by the ICOS Flask and Calibration Laboratory (FCL) and amount fractions are traceable to the WMO calibration scales <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx80" id="paren.45"/>. The CO<sub>2</sub> amount fraction is measured every second and averaged to 2 min by a non-dispersive infrared (NDIR) analyser from Siemens Corp. Full details on instrumentation, measurement protocol, and calibration strategy can be found in <xref ref-type="bibr" rid="bib1.bibx1" id="text.46"/>.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Processing of atmospheric radon data: towards a standard protocol</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Detector control and data collection</title>
      <p id="d2e1887">Operation of the ANSTO detectors, their data logger, and calibration units are controlled by Radon Detector Monitor (RDM) software installed on local site computers. For PC operating systems prior to Windows 10, a Visual Basic GUI version of RDM was distributed. For Windows 10 or later, as well as for Linux systems, a Python-based GUI version of RDM has been available since August 2022 (<uri>https://github.com/anstoradonlab/radon-monitor/releases/</uri>, last access: 24 March 2024). RDM is responsible for the collection, display, and storage of all raw detector output (see Fig. <xref ref-type="fig" rid="Ch1.F3"/> and elaborated further in Table <xref ref-type="table" rid="App1.Ch1.S1.T4"/>), and based on user-defined parameters, it maintains full control of scheduled calibration and background events. However, calibrations and backgrounds can also be remotely reconfigured and initiated if the computer has network connectivity.</p>

      <fig id="Ch1.F3" specific-use="star"><label>Figure 3</label><caption><p id="d2e1899">Workflow to calculate the best estimate of radon activity concentration: this flow illustrates the processing steps from measured “raw” detector output through calculated parameters and constants to derive the best estimate of radon activity concentration, as described in detail in Sect. <xref ref-type="sec" rid="Ch1.S3"/>. The parameters which influence the uncertainty derived from the deconvolution process are also highlighted (described in Sect. <xref ref-type="sec" rid="Ch1.S3.SS7"/>).</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f03.png"/>

        </fig>

      <p id="d2e1912">All measurement and diagnostic quantities associated with the radon detector operation are polled by the internal Campbell Scientific CR800 data logger every 10 s, then totalled or averaged every 30 min. Totalized counts include LLD, ULD, and sample flow rate (measured using a domestic gas meter that has a 2.0 L cyclic volume with individual cycles counted optically), while all other parameters are averaged (see Fig. <xref ref-type="fig" rid="Ch1.F3"/>).</p>
      <p id="d2e1918">RDM retrieves data from the logger every 30 min and saves monthly files in two formats: CSV and SQL database files. The CSV files only contain 30 min records of raw measurement and diagnostic quantities, kept small (<inline-formula><mml:math id="M118" display="inline"><mml:mo lspace="0mm">&lt;</mml:mo></mml:math></inline-formula> 140 kB per month) for ease of remote file transfer. The database files contain all 10 s and 30 min raw and diagnostic quantities, full status and operational information from the calibration system, and a complete log of system and error messages (<inline-formula><mml:math id="M119" display="inline"><mml:mo lspace="0mm">&lt;</mml:mo></mml:math></inline-formula> 2 MB per month).</p>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Data quality control, background determination, and calibration</title>
      <p id="d2e1943">The first step of quality control is to check and correct any data time-stamping errors. Issues such as power supply disruptions, logger malfunctions, or communication errors can lead to missed, duplicated, or incomplete data records.</p>
      <p id="d2e1946"><italic>LLD counts</italic>. The internal and external flow rate, ULD, high voltage, and tank pressure are the critical factors that give an indication of whether the LLD count is going to be flagged as valid or invalid. For a given time point, if these parameters vary beyond designated site-specific limits determined to reduce their accuracy, LLD is rejected. LLD values below instrumental background were set to a radon concentration of zero.</p>
      <p id="d2e1951">The ratio of detector volume (e.g. 1500 L) to sampling flow rate (external flow loop; L min<sup>−1</sup>) determines the time that sampled air is delayed inside the detector (during which some of the sampled <sup>222</sup>Rn will decay). The delay time should be between 15–20 min, necessitating a flow rate between 75–100 L min<sup>−1</sup>.</p>
      <p id="d2e1987">The flow rate of the internal flow loop should be sufficient to exchange all the air within the detector through the measurement head in less than 3 min (the half-life of <sup>218</sup>Po). Flow within central pipe of the detector is measured as a velocity (V) with an insertion probe at the centre of the 50 mm inner diameter pipe. Based on the typical velocity profile in a pipe, the actual flow rate is estimated as 80 % of the maximum flow rate (<inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:math></inline-formula>). While a flow rate of around 5.5 m s<sup>−1</sup> is technically sufficient for this purpose, a faster rate is desirable, and values of 6–12 m s<sup>−1</sup> are typically achievable (based on individual blower performance and flow impedance of the measurement head).</p>
      <p id="d2e2035">The main detector volume is kept at a slight positive pressure with respect to ambient (described in more detail in Sect. <xref ref-type="sec" rid="Ch1.S2.SS2.SSS2"/>) to prevent near-surface air from entering the detector should any leaks develop. A large leak would reduce this pressure and a system blockage downstream would increase it. The micro mass flow controller used to estimate this overpressure has a millivolt (mV) output (prone to some calibration drift). An option exists to enter user-defined calibration coefficients for this sensor (ideally updated annually) to retrieve output in Pa, but raw output in the range 2200–2400 mV approximately corresponds to an overpressure of 1.0–1.2 hPa.</p>
      <p id="d2e2040">The sensitivity of the photomultiplier tube in the measurement head changes with the supply voltage. The operating high voltage is unique to each detector counting system and is determined when the detector is commissioned (and rechecked if any of the detector electronics are changed). Once set, this value should not be allowed to change by more than ±10 V without being manually readjusted back to the nominated value.</p>
      <p id="d2e2043">The counting system of two-filter detectors is sensitive to electrical, electromagnetic, and some radio frequency noise. Ideally the detectors should be operated on their own power circuit or through an uninterruptible power supply (UPS), and large electrical motors (e.g. pumps, compressors) should not be operated nearby. These forms of noise typically result in raw counts of a higher voltage than counts due to <inline-formula><mml:math id="M127" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> decay. A voltage discrimination threshold of 1.0 V is set within the counting electronics to distinguish between raw <inline-formula><mml:math id="M128" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> counts from radon progeny (LLD) and noise counts (ULD). Ideally, the ULD counts represent the number of LLD counts that are due to noise. When few noise counts are present (e.g. <inline-formula><mml:math id="M129" display="inline"><mml:mo>≤</mml:mo></mml:math></inline-formula> 1 counts min<sup>−1</sup>; site-specific), net counts (LLD–ULD) can still be representative of the raw radon count. Notably, at TAC, ULD counts consistently ranged between 3–7 counts min<sup>−1</sup> throughout the entire measurement period. It is important to note that this noise originated from the pump of another instrument. Discarding all measurements made it impractical to implement flagging in this context. Nevertheless, ongoing efforts are being made to develop solutions aimed to mitigate the noise, alongside the ongoing evaluation of uncertainties associated with these noise counts.</p>
      <p id="d2e2091">As an example, Table <xref ref-type="table" rid="Ch1.T1"/> summarizes the designated acceptable limits of diagnostic quantities for the HFD 1500 L radon monitor.</p>

<table-wrap id="Ch1.T1"><label>Table 1</label><caption><p id="d2e2099">Quality check parameters for LLD flagging: critical factors (internal and external flow rate, ULD, high voltage, differential pressure) with minimum and maximum values – highlighted through HFD site-specific thresholds.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Parameter</oasis:entry>
         <oasis:entry colname="col2">Min</oasis:entry>
         <oasis:entry colname="col3">Max</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">value</oasis:entry>
         <oasis:entry colname="col3">value</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">External flow (L min<sup>−1</sup>)</oasis:entry>
         <oasis:entry colname="col2">75</oasis:entry>
         <oasis:entry colname="col3">100</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Internal flow (m s<sup>−1</sup>)</oasis:entry>
         <oasis:entry colname="col2">6</oasis:entry>
         <oasis:entry colname="col3">12</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Voltage (V)</oasis:entry>
         <oasis:entry colname="col2">715</oasis:entry>
         <oasis:entry colname="col3">735</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Differential pressure (mV)</oasis:entry>
         <oasis:entry colname="col2">2000</oasis:entry>
         <oasis:entry colname="col3">2600</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Upper limit of discrimination (count (30 min)<sup>−1</sup>)</oasis:entry>
         <oasis:entry colname="col2">0</oasis:entry>
         <oasis:entry colname="col3">35</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e2239">The final considerations for flagging the LLD data are background, calibration, and maintenance events or power failures. The detector is out of operation for the entire 24 h background check, as well as up to 2 h after the detector restarts. The detector is also out of operation for the 5 h source injection period of a calibration, as well as the 6 h period required to flush the enhanced radon out of the detector. During maintenance periods there are higher risks of <sup>220</sup>Rn contamination (if the detector has been opened) or diagnostic parameters being out of range. After power failures it can take the detector 1–2 h to return to normal monitoring conditions. All such periods should be flagged out of the final raw dataset prior to further processing.</p>

      <fig id="Ch1.F4" specific-use="star"><label>Figure 4</label><caption><p id="d2e2253">Instrumental background events for three sites: <bold>(a)</bold> WAO, <bold>(b)</bold> HFD, and <bold>(c)</bold> TAC, covering the period from the initiation of measurements until August 2021. Assigned background events are highlighted (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/> for details of assigned values). Corresponding 6-month fitted instrumental background rates are shown for <bold>(d)</bold> WAO, <bold>(e)</bold> HFD, and <bold>(f)</bold> TAC (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/> for details of fitting).</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f04.png"/>

        </fig>

      <p id="d2e2285"><italic>Instrumental background event</italic>. Once background checks had been initiated as outlined in Sect. <xref ref-type="sec" rid="Ch1.S2.SS2.SSS4"/> and other diagnostic parameters (high voltage and noise; Table <xref ref-type="table" rid="Ch1.T1"/>) were verified to be within acceptable ranges, each background (Fig. <xref ref-type="fig" rid="Ch1.F4"/>a–c) was processed as follows: the initial 6 h of the 24 h period were removed, the last 30 min sample was excluded if the blowers restarted early (due to the small time differences that can happen between the PC clock and the logger clock if they are not regularly synchronized), and a check was made that the remaining data were approximately constant and free of noise counts. The median of these values was then taken to be the background reading.</p>
      <p id="d2e2296">During the measurement period presented here, an important observation is that each of the three sites depicted in Fig. <xref ref-type="fig" rid="Ch1.F4"/>a–c experienced an instance where a background event was not recorded. In each case this missing background event was labelled “assigned background”, for which the method of determination is explained in  Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/>. Typically, instrumental background checks are automated and scheduled quarterly. However, a deviation from this established routine sometimes occurred due to a software crash, leading to a significant gap in the background check process.</p>
      <p id="d2e2303"><italic>Calibration event</italic>. The calibration plan for all radon detectors in this study was for monthly calibrations (scheduled in RDM to occur on the same day of each month) such that the calibration peak (<inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">peak</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) occurred between 13:00–14:00 LST to coincide with a deep, well-mixed boundary layer. Consequently, any calibration events for which <inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">peak</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> did not occur within this time window were rejected. All sites in this study also had regular exposure to “baseline” atmospheric conditions (medium- to long-term oceanic fetch conditions, with low variability in radon concentrations). Consequently, a site-specific threshold value was set for the ambient radon count representing the upper limit of baseline variability (50 counts min<sup>−1</sup>), and any calibration event for which the estimated <inline-formula><mml:math id="M139" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mrow><mml:mi mathvariant="normal">peak</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">a</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> exceeded this value was flagged.</p>

      <fig id="Ch1.F5" specific-use="star"><label>Figure 5</label><caption><p id="d2e2361">Monthly calibration coefficients for three sites: <bold>(a)</bold> WAO, <bold>(b)</bold> HFD, and <bold>(c)</bold> TAC, covering the period from the initiation of measurements until August 2021. Flagged calibration events are highlighted (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/> for exclusion criteria). Corresponding 6-month fitted calibration coefficients are shown for <bold>(d)</bold> WAO, <bold>(e)</bold> HFD, and <bold>(f)</bold> TAC (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/> for details of fitting).</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f05.png"/>

        </fig>

      <p id="d2e2393">Derived monthly calibration factors for all three sites (WAO, HFD, TAC) are presented in Fig. <xref ref-type="fig" rid="Ch1.F5"/>a–c, covering the period from the initiation of measurements until August 2021. At HFD (Fig. <xref ref-type="fig" rid="Ch1.F5"/>b), the first 6 months were flagged due to sampling flow problems caused by a partial blockage of the inlet line. Other causes of flagged calibration events in Fig. <xref ref-type="fig" rid="Ch1.F5"/>a–c were attributed to the threshold exceedance of <inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mrow><mml:mi mathvariant="normal">peak</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">a</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, calibrations occurring at night due to software crashes, and insufficient flushing of the source. For example, the last three calibration events at TAC (Fig. <xref ref-type="fig" rid="Ch1.F5"/>c, June, July and August 2021) were all too high due to a poorly flushed source. The source flushing time at all sites was originally set to 5 h (typical for 20 kBq <sup>226</sup>Ra sources). However, all sources in this study had activities <inline-formula><mml:math id="M142" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 30 kBq <sup>226</sup>Ra (see Table <xref ref-type="table" rid="App1.Ch1.S1.T3"/>) and it was determined that effective flushing of the source capsules required flushing periods lasting 8–12 h at 0.15 L min<sup>−1</sup>. Older-style calibration systems were used in this study (using pumps and needle-valve flow control, not compressed gas and a mass flow controller), so it was important to regularly check and correct the source's flushing.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Data continuity: fitting instrument calibration and background</title>
      <p id="d2e2468">Under normal detector operation, there is no physical basis for short-term deviations from a slow, long-term linear decrease in detector sensitivity (this is controlled by gradual deterioration of consumable materials inside the measurement head). Therefore, such events evident in Fig. 5d–f are more likely a result of uncertainty in the calibration process than real changes in detector performance. This is why the linear model for calibrations described in <xref ref-type="bibr" rid="bib1.bibx14" id="text.47"/>, applied retrospectively, is more accurate. When applying fitting algorithms, as described in the following section, to enable continuous near-real-time access to calibrated radon concentrations, it should be understood that additional uncertainty is introduced. To ensure a continuous time series and to avoid unnecessary step changes, the Savitzky–Golay fitting method is used on successive subsets of calibration coefficients and instrumental background counts. This method involves the following steps. <list list-type="order"><list-item>
      <p id="d2e2476"><italic>Fitting window size</italic>. Calibration and background values are selected within a specific range. This range as a 184 d moving window centred on each of the time stamps.</p></list-item><list-item>
      <p id="d2e2483"><italic>Fitting</italic>. Within the defined window, a curve is fitted through the selected values using a first-order polynomial linear fit based on the data points available in the defined window.</p></list-item><list-item>
      <p id="d2e2489"><italic>Smoothing window size</italic>. The result of the moving fit requires further smoothing. The centre moving average is used as the 184 d moving window centred on each of the time stamps.</p></list-item><list-item>
      <p id="d2e2495"><italic>Smoothing</italic>. The centre moving average is performed on the results of Step 2. This is to smooth out the effect of multiple adjacent data points sharing the same measurements for the fitting, which may result in step changes.</p></list-item><list-item>
      <p id="d2e2501"><italic>Handling edge data</italic>. To ensure a smooth transition at the beginning of the dataset, the data points prior to the first calibration and/or background measurement will be assigned the fitted value from that measurement. Similarly, for the end of the dataset, the fitted value from the last calibration and/or background measurement will be used to fill in the remaining data points.</p></list-item></list> For the purpose of reproducibility, the implemented code is provided in the Supplement.</p>
      <p id="d2e2507">In the rolling fit process, it is crucial to compare the current fitting with the preceding one, particularly in periods of overlap. In this regard, two types of data ranges are recommended: (i) the data range for selecting raw data and performing the fit and (ii) the data range where the fitted data will actually be utilized. Additionally, the effectiveness of the Savitzky–Golay fitting method can be affected by gaps within the defined window. This issue is evident across the three sites, with distinct gaps in background counts observed (see Fig. <xref ref-type="fig" rid="Ch1.F4"/>). To address this, the concept of “assigned” values is introduced. First, data gaps larger than either the defined half-window size for fitting or a predetermined maximum gap are identified. The number of points to be inserted into these gaps is then determined using the ceiling function:
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M145" display="block"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mfenced open="⌈" close="⌉"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="normal">gap</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are the time coordinates at either end of the gap. The resulting  data points to be input are inserted evenly within the gap, with spacing adjusted to the nearest 30 min. The gap is then linearly interpolated between the closest available data points to construct this number of new data points, evenly spaced across the gap to the nearest 30 min. For HFD, gap<sub>max⁡</sub> is set to 93 d.</p>
      <p id="d2e2577">Figures <xref ref-type="fig" rid="Ch1.F4"/>d–f and <xref ref-type="fig" rid="Ch1.F5"/>d–f display fitted instrumental background (<inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">bg</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and the fitted calibration coefficient (<inline-formula><mml:math id="M150" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">cal</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) for three sites: WAO, HFD, and TAC. The fitted coefficients reveal a site-dependent annual reduction in detector sensitivity, varying from 3.2 % to 4.7 %. These reduction percentages are calculated based on the fitted calibration coefficients and represent the decline relative to the preceding year. At WAO, situated along the coast with the lowest source strength (see Table <xref ref-type="table" rid="App1.Ch1.S1.T3"/>) and a sampling inlet, the calibration coefficient experienced a 3.2 % yr<sup>−1</sup> decrease. Similarly, TAC, with the highest sampling inlet, also witnessed sensitivity reductions of 3.3 % yr<sup>−1</sup>, although it recorded the highest background rates among the three sites. The main reason for increased background is the ULD noise, but  other factors may also contribute such as <sup>220</sup>Rn contamination at this site and ingrowth of radon from <sup>226</sup>Ra inside the detector. In contrast, the HFD detector exhibited a notably faster sensitivity decrease of 4.7 %, accompanied by the lowest background counts. The acceleration of reduction in sensitivity and increase in background rate will vary for each instrument, as every batch of materials used for making components has distinct levels of trace contamination of <sup>226</sup>Ra and different consumable materials within the detector head, specifically the ZnS(Ag) scintillation material. However, it is also worth noting that the fitting procedure can make the annual rate of decline appear larger compared to a linear model of calibration sensitivity change. This effect is sometimes more pronounced in certain cases, such as in Fig. <xref ref-type="fig" rid="Ch1.F5"/>d, where edge effects come into play.</p>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Instrument response time correction</title>
      <p id="d2e2670">The operational principle of the two-filter detector, briefly discussed in Sect. <xref ref-type="sec" rid="Ch1.S2.SS2.SSS1"/>, inherently causes a delay in reporting the true LLD signal. Approximately 40 % of the signal is observed 1 h after the radon pulse is delivered <xref ref-type="bibr" rid="bib1.bibx31" id="paren.48"/>. This delay necessitates time response correction, particularly when employing sub-diurnal radon measurements for quantitative analysis or comparison with fast-response instruments like GHG detectors. <xref ref-type="bibr" rid="bib1.bibx31" id="text.49"/> explored methods to correct for the detector's slow response, highlighting the effectiveness of a Bayesian approach using a Markov chain Monte Carlo sampler – a methodology employed here for deconvoluting the radon time series. The aim of deconvolution is to estimate the true signal within the temporal context while preserving the radon concentration levels. The deconvolution is performed on the LLD counts, where all flagged LLD counts are removed prior to this step. Along with LLD counts, the fitted calibration coefficient, and instrumental background, the deconvolution routine also requires several output parameters: both external and internal flow rates, the detector's temperature, and the physical detector's parameters, including its size and the thoron delay volume. The fitted instrumental background values are subtracted from the deconvolved LLD counts (<inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">dec</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>). Following this subtraction, the <inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">dec</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values are then processed to calculate the activity concentration (Bq m<sup>−3</sup>) of <sup>222</sup>Rn, and the equation is as follows.
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M160" display="block"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">222</mml:mn></mml:msup><mml:mi mathvariant="normal">Rn</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced open="(" close=")"><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">dec</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">bg</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mn mathvariant="normal">1800</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">cal</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e2765">For a given time stamp in the time series, the mean of the deconvolution result at that time stamp is reported as the radon concentration of that particular time stamp.</p>
</sec>
<sec id="Ch1.S3.SS5">
  <label>3.5</label><title>Standard reference temperature and pressure correction</title>
      <p id="d2e2777">The last step of data processing involves normalizing the deconvolved concentration of radon to standard reference temperature (<inline-formula><mml:math id="M161" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and pressure (<inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) conditions (Bq m<sup>−3</sup> STP). For our case, we adapted the International Standard Atmosphere (288.15 K and 101 325 Pa). This standard was selected mainly due to its representative average, as 15 °C approximates the average annual ambient temperature of the Earth's surface in temperate regions and makes it easier to  compare across different regions and times of the year. This normalization is achieved through a correction term as follows:
            <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M164" display="block"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">222</mml:mn></mml:msup><mml:mi mathvariant="normal">Rn</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mfenced close=")" open="("><mml:mrow><mml:msub><mml:mi mathvariant="normal">LLD</mml:mi><mml:mi mathvariant="normal">dec</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">bg</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mn mathvariant="normal">1800</mml:mn><mml:mo>×</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">cal</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mfenced open="(" close=")"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">inst</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">inst</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where (<inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">inst</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and (<inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">inst</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) are temperature and pressure inside the detector's main delay volume.</p>
      <p id="d2e2914">This correction removes sensitivity to measurement height, facilitating comparison with modelled activity concentrations, and ensures that observed trends in radon concentration are solely due to environmental variations in mixing ratio brought about by changing air mass fetch and transport times.</p>
      <p id="d2e2917">Regarding the harmonization of radon observations across European and global networks, it should be noted that some atmospheric radon monitors operating within ICOS and other networks (e.g. the HRM; <xref ref-type="bibr" rid="bib1.bibx45" id="altparen.50"/>) automatically implement an STP correction that assumes different pressure and temperature reference values (<inline-formula><mml:math id="M167" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">273.15</mml:mn></mml:mrow></mml:math></inline-formula> K, <inline-formula><mml:math id="M168" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">100</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mn mathvariant="normal">000</mml:mn></mml:mrow></mml:math></inline-formula> Pa). Other monitors (e.g. the ARMON; <xref ref-type="bibr" rid="bib1.bibx32" id="altparen.51"/>) do not measure pressure and temperature directly within the instrument delay volume and can therefore only make approximate STP corrections.</p>
</sec>
<sec id="Ch1.S3.SS6">
  <label>3.6</label><title>Atmospheric water vapour corrections</title>
      <p id="d2e2967">Water is a volatile component of the atmosphere. As such, water vapour can vary rapidly in space and time. Through the dilution effect, these changes can influence observed concentrations of other atmospheric constituents. Some radon monitors in European networks (e.g. the ARMON) dry sampled air prior to analysis. Furthermore, modelled radon values are usually reported as dry-air mole fractions. For harmonization and intercomparison purposes, radon monitors should provide the ability to correct for water vapour effects.</p>
      <p id="d2e2970">ANSTO radon detectors measure the pressure, temperature, and relative humidity (RH) of air in the main delay volume, directly adjacent to the detector measurement head, providing a pathway for water vapour correction if required. However, the process of accurately converting RH into water vapour pressure involves navigating several challenges, including temperature dependencies, measurement accuracy, environmental variability, and assumptions in calculation equations. One commonly used method for this conversion is the Clausius–Clapeyron equations, refined with the Magnus approximation, with constants from <xref ref-type="bibr" rid="bib1.bibx2" id="text.52"/>. The equations are based on certain assumptions and empirical data, which might not reflect all environmental conditions, therefore introducing systematic errors. Another critical aspect to consider is that calibration of the radon detector is not based on dry air (the ambient air is used to flush the source), complicating the direct comparisons.</p>

<table-wrap id="Ch1.T2" specific-use="star"><label>Table 2</label><caption><p id="d2e2979">Comparison of dry and wet air across UK extreme climate conditions: evaluating the need for water vapour correction.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Scenario</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M173" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (hPa)</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M174" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (°C)</oasis:entry>
         <oasis:entry colname="col4">RH (%)</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M175" display="inline"><mml:mrow><mml:msub><mml:mi>e</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (hPa)</oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M176" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M177" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">1053.6</oasis:entry>
         <oasis:entry colname="col3">40.3</oasis:entry>
         <oasis:entry colname="col4">100</oasis:entry>
         <oasis:entry colname="col5">74.93842</oasis:entry>
         <oasis:entry colname="col6">0.9558</oasis:entry>
         <oasis:entry colname="col7">0.8879</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2</oasis:entry>
         <oasis:entry colname="col2">1053.6</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M178" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>27.5</oasis:entry>
         <oasis:entry colname="col4">100</oasis:entry>
         <oasis:entry colname="col5">0.644756</oasis:entry>
         <oasis:entry colname="col6">1.2197</oasis:entry>
         <oasis:entry colname="col7">1.2189</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3</oasis:entry>
         <oasis:entry colname="col2">925.6</oasis:entry>
         <oasis:entry colname="col3">40.3</oasis:entry>
         <oasis:entry colname="col4">100</oasis:entry>
         <oasis:entry colname="col5">74.93842</oasis:entry>
         <oasis:entry colname="col6">0.8397</oasis:entry>
         <oasis:entry colname="col7">0.7717</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4</oasis:entry>
         <oasis:entry colname="col2">925.6</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M179" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>27.5</oasis:entry>
         <oasis:entry colname="col4">100</oasis:entry>
         <oasis:entry colname="col5">0.644756</oasis:entry>
         <oasis:entry colname="col6">1.0715</oasis:entry>
         <oasis:entry colname="col7">1.0707</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5</oasis:entry>
         <oasis:entry colname="col2">1013.2</oasis:entry>
         <oasis:entry colname="col3">15.0</oasis:entry>
         <oasis:entry colname="col4">100</oasis:entry>
         <oasis:entry colname="col5">17.01983</oasis:entry>
         <oasis:entry colname="col6">1.0000</oasis:entry>
         <oasis:entry colname="col7">0.9832</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d2e2982">Note that the wet-air correction factor (<inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) is calculated with the formula <inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:mn mathvariant="normal">273.15</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></inline-formula>. Similarly, the dry-air correction factor (<inline-formula><mml:math id="M171" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) employs the formula <inline-formula><mml:math id="M172" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">stp</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>e</mml:mi><mml:mrow><mml:mi mathvariant="normal">s</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">RH</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:mn mathvariant="normal">273.15</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></inline-formula>.</p></table-wrap-foot></table-wrap>

      <p id="d2e3354">To assess the necessity of correcting water vapour, a simple calculation was carried out to compare the difference between dry (<inline-formula><mml:math id="M180" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and wet (<inline-formula><mml:math id="M181" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) air across a spectrum of UK extreme climate conditions, as indicated in Table <xref ref-type="table" rid="Ch1.T2"/>. The maximum observed discrepancy of 7.1 % indicated the difference in water vapour concentration between dry and wet air in scenarios of the highest temperature and pressure. The discrepancy was minimal (0 %–2 %) for air temperature spanning 0 to 30 °C. Considering the minimal impact of correcting the water vapour and potential for such correction to introduce noise or errors through another layer of data analysis, especially after the deconvolution process, this correction was omitted. However, detector temperature and RH are reported along with radon concentration so that data users can make this correction themselves if necessary.</p>
</sec>
<sec id="Ch1.S3.SS7">
  <label>3.7</label><title>Combined measurement uncertainty</title>
      <p id="d2e3389">The uncertainty associated with the reported radon concentration is derived from the posterior distribution resulting from the deconvolution process. This uncertainty is influenced by the following. <list list-type="bullet"><list-item>
      <p id="d2e3394"><italic>Gross</italic> <inline-formula><mml:math id="M182" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> <italic>counting</italic>. Governed by a Poisson distribution, this uncertainty reflects the statistical variability inherent in counting process.</p></list-item><list-item>
      <p id="d2e3410"><italic>Flow rate variability</italic>. The external flow rate introduces an uncertainty of 2 %. Variations in the external flow rate, especially rapid changes, can significantly affect the response time of the detector. <xref ref-type="bibr" rid="bib1.bibx31" id="text.53"/> demonstrated that the deconvolution tends to over-correct the time series if the external flow rate is halved. The internal flow rate contributes a substantial uncertainty of 20 %. Optimizing the internal flow rate is critical for a few reasons: (i) to account for the rapid decay of radon's first <inline-formula><mml:math id="M183" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>-emitting progeny (<sup>218</sup>Po, half-life of 3.1 min) and (ii) to minimize the time for plate-out of unattached radon progeny on the internal surfaces of the detector. To further reduce opportunities for the plate-out of radon progeny inside the detector, a flow homogenization screen is implemented to reduce strong turbulent mixing inside the detector's main delay volume. This screen ensures a more laminar (plug-like) flow towards the measurement head.</p></list-item><list-item>
      <p id="d2e3435"><italic>Plate-out effect</italic>. An absolute uncertainty of 2 % is given to the plate-out effect.</p></list-item><list-item>
      <p id="d2e3441"><italic>Screening efficiency</italic>. A 5 % absolute uncertainty is associated with the screening efficiency in homogenizing airflow and reducing turbulence.</p></list-item><list-item>
      <p id="d2e3447"><italic>Delay time</italic>. The delay time represents the lag in the system, with an absolute uncertainty of 1 %, and can arise from various sources such as extended inlet lines and synchronization of the data logger. While this delay time does not significantly impact the deconvolution routine, it will become critical when aligning the detector's response time with a large,  brief spike of counts.</p></list-item><list-item>
      <p id="d2e3453"><italic>Field calibration coefficient</italic>. The calibration coefficient, with an overall uncertainty of 5 %, incorporates several aspects: the <sup>226</sup>Ra source accuracy with an absolute uncertainty of 4 % and an additional 1 % uncertainty arising from variation in the radon production rate, scaling factor, and decay constant.</p></list-item></list></p>
      <p id="d2e3467">In addition to the abovementioned uncertainties, there are other significant uncertainties that, although not currently addressed, should be considered in future analyses. These include uncertainties related to STP corrections, which typically stem from the accuracy, calibration, and response time of temperature and pressure sensors. A critical area to address is the uncertainty associated with field calibration of 1500 L detectors, which involves interpolating ambient counts (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS2.SSS3"/>), although this problem can be eliminated by employing a portable calibration transfer standard detector <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx59" id="paren.54"/>. Another improvement in the uncertainty quantification includes instrumental background and calibration events themselves, alongside the “assigned” values (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/>), with the latter having higher uncertainties.</p>
      <p id="d2e3477">For reporting, half of the difference between the 16th and 84th percentile of the deconvolution result for a particular time stamp is taken as the uncertainty of the radon concentration.</p>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Assessing the accuracy of the best radon activity concentration estimate</title>
      <p id="d2e3489">Two approaches are used to evaluate the accuracy of the deconvolved radon concentration. The first approach, under “controlled conditions”, employs calibration events to validate both the absolute achieved concentration and the temporal alignment between estimated and measured radon values. The second approach, based on “real-world conditions”, directly compares estimated radon concentrations with the GHG amount fractions obtained from fast-response detectors.</p>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Validating radon activity concentration estimates under controlled conditions</title>
      <p id="d2e3499">Figure <xref ref-type="fig" rid="Ch1.F6"/>a–b depict calibration events in July 2021 from two locations: HFD and WAO. In each case, radon concentrations (<sup>222</sup>Rn<sub>ini</sub>) were measured following a direct 5 h injection from a <sup>226</sup>Ra source, and then the deconvolution algorithm was applied (<sup>222</sup>Rn).</p>

      <fig id="Ch1.F6" specific-use="star"><label>Figure 6</label><caption><p id="d2e3542">Comparison of initial and best radon concentration estimates (with the 16th–84th percentile range shaded) during a calibration event with a constant-delivery radon concentration in July 2021 at <bold>(a)</bold> HFD and <bold>(b)</bold> WAO, alongside a calibration event with non-constant radon delivery in August 2021 at <bold>(c)</bold> HFD. The orange line shows that the signal reached only 85 % of its target by 09:00 LST. The shaded area represents the ideal square wave.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f06.png"/>

        </fig>

      <p id="d2e3560">Specifically in the case of these events, when the deconvolution algorithm was applied some adjustments were necessary to enhance the algorithm's efficiency. Firstly, because the calibration stream of radon was injected directly into the detector (not at the sampling inlet point), the thoron delay volume value was set to zero. Secondly, since environmental atmospheric radon concentrations do not usually exhibit abrupt changes of the magnitude seen during calibration events, the smoothness constraints of the deconvolution routine were adjusted to accurately track the sudden change in radon concentration as the calibration source is turned on and off.</p>
      <p id="d2e3564">The purpose of the deconvolution algorithm is to correct the delay between the sampled radon concentration and the detected signal, and here we demonstrate that the implementation of the deconvolution algorithm is successful at the HFD and WAO sites. In the case of a defined calibration injection period from a well-flushed source, the target result is essentially a square wave (bearing in mind that the detector reports concentrations at the end of each measurement period and continues to sample ambient air throughout the injection period). As shown in Fig. <xref ref-type="fig" rid="Ch1.F6"/>a–b, despite the source injection being initiated at 08:00 LST at both sites, the signal from both detectors (purple line) had only reached around 85 % of its target value by 09:00 LST. Similarly, after injection stops (13:00 LST at HFD, 14:00 LST at WAO), the signal from each detector takes around 3 h to return to near ambient. By comparison, the deconvolved signal (yellow line) exhibits a full increase in concentration within the first hour (the temporal resolution of these measurements) and shows an almost complete return to ambient concentrations in the hour after injection stops. The observed behaviour of the response-time-corrected data demonstrates the effectiveness of the deconvolution process in recreating sudden, unrealistically large changes in radon concentration, lending credence to the claimed accuracy, precision, and reliability under real-world scenarios.</p>
      <p id="d2e3569">As evident in Fig. <xref ref-type="fig" rid="Ch1.F6"/>a–b, when the deconvolved radon signal from a calibration injection depicts a near-ideal square wave, it usually takes the uncorrected detector output 3 to 5 h to reach a similar activity concentration (based on overlapping uncertainty bounds). Often, something that is more clearly evident in the deconvolved output for calibration injection events are times when the source capsule has not been adequately flushed prior to the start of an injection (see Fig. <xref ref-type="fig" rid="Ch1.F6"/>c). In these cases, a clear “overshoot” of radon concentration is observed, followed by a gradual return to the target concentration over the 5 h injection period as the excess radon is flushed from the detector's main delay volume. These tests of the deconvolution routine on extreme changes under controlled conditions provide confidence in the fidelity of the technique under real-world conditions.</p>
</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Validation of the best estimated radon activity concentration under real-world conditions </title>
      <p id="d2e3584">Changes in air mass fetch, transitioning from terrestrial to oceanic or vice versa, lead to significant variations in atmospheric trace gas constituents. When associated with strong frontal systems, such changes can occur over short timescales – comparable to the 3–5 h it takes a two-filter radon detector to fully respond to a sustained calibration injection.</p>

      <fig id="Ch1.F7" specific-use="star"><label>Figure 7</label><caption><p id="d2e3589">Response of CH<sub>4</sub> and radon (initial and best estimate) to rapid air mass changes in winter: <bold>(a)</bold> HFD and <bold>(b)</bold> WAO. </p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f07.png"/>

        </fig>

      <p id="d2e3613">In Fig. <xref ref-type="fig" rid="Ch1.F7"/>, we illustrate the response of CH<sub>4</sub> as measured by a fast-response analyser (0.4 Hz) to a rapid change in air mass fetch during the winter period (22–23 February 2021) at HFD and WAO. Additionally,  Fig. <xref ref-type="fig" rid="Ch1.F7"/> presents the corresponding radon measurements, both with and without response time correction via deconvolution.</p>
      <p id="d2e3630">Initially, on 22 February, a period of pollution is evident, characterized by elevated radon concentrations and CH<sub>4</sub> amount fractions, attributed to continental influences. However, a rapid transition to baseline conditions for both gases occurs as air masses shift towards cleaner oceanic origins on 23 February. This transition is corroborated by air history maps generated using the Met Office NAME Lagrangian atmospheric dispersion model for each site (not shown here).</p>
      <p id="d2e3643">Analysing the reference CH<sub>4</sub> time series reveals the elimination of the time lag between CH<sub>4</sub> amount fraction and deconvolved radon compared to the initial measurements. Moreover, at both sites, the duration of CH<sub>4</sub> transition from polluted peak to baseline conditions aligns with deconvolved radon measurements.</p>
      <p id="d2e3673">Accurately representing radon concentrations holds significant importance, particularly when radon is used as a quantitative tracer for improving and validating ATMs as well as estimating local to regional GHG fluxes via RTM <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx46" id="paren.55"/>.</p>
      <p id="d2e3679">Trace gases can mix through the depth of the planetary boundary layer (PBL) on timescales of around 1 h <xref ref-type="bibr" rid="bib1.bibx63" id="paren.56"/>. Consequently, before attempting to employ radon to improve understanding of the dilution of atmospheric constituents with surface sources it is crucial that instrument response time is accounted for (see Fig. 10 in <xref ref-type="bibr" rid="bib1.bibx31" id="altparen.57"/>). Here we further demonstrate the effectiveness of the deconvolution technique under real-world conditions by analysing diurnal composites of radon, CH<sub>4</sub>, CO<sub>2</sub>, and N<sub>2</sub>O. The diurnal cycle of trace gases with surface sources is characterized by a morning maximum, when the mixing depth is shallowest, and an afternoon minimum, when convective mixing is deepest. After sunrise, when the nocturnal inversion breaks down and the daytime inversion begins to grow, concentrations are  rapidly reduced from their morning maximum to their afternoon minimum values. In the absence of short-term sinks (e.g. photosynthesis) or temporal changes in source function, all gases should be impacted equally by this dilution.</p>
      <p id="d2e3715">Focusing primarily on the warmer season – summer – is crucial for our analysis because of gases' pronounced diurnal variation in PBL height. This variation offers an ideal testing ground to evaluate the effectiveness of the radon deconvolution tool.</p>

      <fig id="Ch1.F8" specific-use="star"><label>Figure 8</label><caption><p id="d2e3721">Summer diurnal composites of the best estimates of radon activity concentration and GHG amount fractions at TAC, HFD, and WAO for <bold>(a)</bold> radon and CH<sub>4</sub>, <bold>(b)</bold> radon and CO<sub>2</sub>, and <bold>(c)</bold> radon and N<sub>2</sub>O. Composites are based on hourly median values spanning June to August. Shaded areas indicate the 25th to 75th percentile to visualize variability of gases.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f08.png"/>

        </fig>

      <p id="d2e3767">Hourly median summer diurnal composites of the best estimates of radon (deconvolved and STP corrected) and GHGs at TAC, HFD, and WAO are presented in Fig. <xref ref-type="fig" rid="Ch1.F8"/>. At each of these sites, radon and the GHGs were sampled from the same (uppermost) inlet height. However, there was an exception at TAC, where radon was sampled at 175 m a.g.l., while GHGs were sampled slightly higher at 185 m a.g.l.</p>
      <p id="d2e3772">During summer nights, the sampling inlets at TAC (175 and 185 m a.g.l.) and HFD (100 m a.g.l.) are typically positioned above the inversion layer. However, the results presented here are based on seasonal median values, which exclude the most extreme and strongly stable nighttime conditions. As a result, for the plots shown (see  Fig. <xref ref-type="fig" rid="Ch1.F8"/>a–b), the inlet heights are effectively situated just at the top of the inversion layer.</p>
      <p id="d2e3777">The rate of increase in nocturnal median levels of trace gases at these sites is small, and a noticeable increase begins around 05:00 LST (coinciding with sunrise) and peaks at 08:00 LST. Figure <xref ref-type="fig" rid="Ch1.F8"/>a (TAC and HFD) indicates synchronous 08:00 LST peaks in radon and CH<sub>4</sub> at both towers. This behaviour is consistent with the destruction of the inversion layer at some time after 05:00 LST, allowing these gases that had accumulated near the surface to mix upwards slowly, past the sampling inlets (typically at or before 08:00 LST). By contrast, WAO measurements are consistently made well within the nocturnal inversion (10 m a.g.l.), and a distinct pattern of decreasing CH<sub>4</sub> and radon levels is observed after sunrise (WAO: Fig. <xref ref-type="fig" rid="Ch1.F8"/>a).</p>
      <p id="d2e3802">The observation of simultaneous peaks in CH<sub>4</sub> and deconvolved radon across all three sites with contrasting sampling heights is a clear validation of the deconvolution technique, highlighting its ability to accurately represent the significant impact of diurnal atmospheric processes on radon concentrations.</p>
      <p id="d2e3814">The difference in radon concentration peaks compared to CO<sub>2</sub> amount fractions at all sites, however, highlights the unique response of these gases to both physical and biological processes (Fig. <xref ref-type="fig" rid="Ch1.F8"/>b–c). The morning peak of CO<sub>2</sub> is observed to occur 3 h earlier than the radon peak at both TAC and HFD sites. This difference can be attributed to the onset of photosynthetic activity. CO<sub>2</sub>, being continuously released by soil respiration, is more quickly affected by surface air movements and sunlight-triggered processes like photosynthesis. As a result, CO<sub>2</sub> is rapidly absorbed by vegetation, resulting in a notable reduction in atmospheric CO<sub>2</sub> levels. In contrast, radon, CH<sub>4</sub>, and N<sub>2</sub>O are less affected by these immediate factors and thus take longer to mix upward from  accumulation near the surface at a slower rate.</p>
      <p id="d2e3884">It is commonly assumed that mixing within the nocturnal boundary layer is uniform; however, this is not the case. A concentration gradient exists from just below the inversion layer to the surface. This gradient is illustrated in Fig. <xref ref-type="fig" rid="Ch1.F9"/>, which shows CO<sub>2</sub> measurements at both the lowest sampling point at HFD (50 m a.g.l.) and the highest sampling point (100 m a.g.l.). The breakdown of the inversion layer around 05:00 LST facilitates vertical mixing of accumulated CO<sub>2</sub> at 50 m a.g.l., a process clearly depicted in  Fig. <xref ref-type="fig" rid="Ch1.F9"/>, which also affects the readings from the 100 m inlet.</p>

      <fig id="Ch1.F9"><label>Figure 9</label><caption><p id="d2e3911">Diurnal composites of the best estimates of radon activity concentration and CO<sub>2</sub> amount fractions measured at 50 and 100 m a.g.l. at HFD during summer. Composites are based on hourly median values. Shaded areas indicate the 25th to 75th percentile to visualize variability of gases.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/18/151/2025/amt-18-151-2025-f09.png"/>

        </fig>

      <p id="d2e3929">At TAC, the morning peak of N<sub>2</sub>O is observed at 06:00 LST, 2 h earlier than the radon peak at 08:00 LST (see Fig. <xref ref-type="fig" rid="Ch1.F8"/>c). This earlier peak can be attributed to soil microbial activity, particularly during nitrification and denitrification processes that are triggered by rising temperatures and increasing sunlight. In contrast, at the HFD and WAO sites, where the inlet is positioned 85 and 175 m lower than at TAC, N<sub>2</sub>O and radon peaks occur simultaneously. This difference in inlet height significantly affects the mixing dynamics at these locations.</p>
      <p id="d2e3952">At the WAO coastal site, the difference in median peak times between radon and CO<sub>2</sub> is likely driven by their distinct source and sink functions (Fig. <xref ref-type="fig" rid="Ch1.F8"/>b), as well as land–sea breezes. Radon exhibits a relatively constant source and sink function compared to CO<sub>2</sub>. Consequently, the radon concentration observed at 10 m a.g.l. is primarily influenced by atmospheric dynamics, particularly the formation and breakdown of the nocturnal inversion, with the peak typically occurring just before the inversion breaks down. Conversely, CO<sub>2</sub> experiences influences from both dynamics and a temporally variable source and sink function. At WAO, CO<sub>2</sub> peaks earlier than radon because photosynthesis begins immediately when the sun rises, drawing CO<sub>2</sub> out of the nocturnal inversion before convective mixing begins, which typically takes an hour or two to initiate due to the warming up process. However, the shaded areas representing the 25th to 75th percentile range for CO<sub>2</sub> variability suggest that this peak frequently coincides with the radon peak.</p>
</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Recommendations</title>
<sec id="Ch1.S5.SS1">
  <label>5.1</label><title>Instrument maintenance</title>
      <p id="d2e4029">As detailed in Sect. <xref ref-type="sec" rid="Ch1.S2.SS2.SSS2"/> some periodic maintenance of the ANSTO two-filter radon detectors is required. Note that some of this information is also included in the commissioning report for the ANSTO instrument.</p>
      <p id="d2e4034"><italic>Weekly</italic>. <list list-type="bullet"><list-item>
      <p id="d2e4041">Visually check that data are updating half-hourly to ensure continuous logging. This can be done remotely.</p></list-item></list></p>
      <p id="d2e4044"><italic>Monthly</italic>. <list list-type="bullet"><list-item>
      <p id="d2e4051">Synchronize the data logger and PC clocks.</p></list-item><list-item>
      <p id="d2e4055">Verify that scheduled events such as calibrations and backgrounds have occurred. This can also be done remotely.</p></list-item></list></p>
      <p id="d2e4058"><italic>Quarterly</italic>. <list list-type="bullet"><list-item>
      <p id="d2e4066">If not using a compressed-air calibration system, inspect and shake the calibration unit's desiccant tube. Confirm that the injection flow rate is within the range of  0.10–0.15 L min<sup>−1</sup>.</p></list-item></list></p>
      <p id="d2e4082"><italic>Yearly</italic>. <list list-type="bullet"><list-item>
      <p id="d2e4089">Check the detector and inlet system for leaks, with half-yearly checks recommended for detectors located outside.</p></list-item><list-item>
      <p id="d2e4093">Inspect the plumbing of the calibration system.</p></list-item><list-item>
      <p id="d2e4097">Check or replace the coarse aerosol filter on the inlet line.</p></list-item></list></p>
      <p id="d2e4100"><italic>2-yearly</italic>. <list list-type="bullet"><list-item>
      <p id="d2e4107">If using a compressed-air calibration system, replace the gas bottle.</p></list-item></list>
<italic>5-yearly</italic>. <list list-type="bullet"><list-item>
      <p id="d2e4116">Refresh the materials inside the detector head (stainless-steel mesh filter and ZnS(Ag) sheet). If components of the aluminium frame of the head have started to corrode, the head casing should also be replaced. ANSTO can provide this service or instructions for replacement (contact: radon@ansto.gov.au).</p></list-item></list></p>
      <p id="d2e4119"><italic>10-yearly</italic>. <list list-type="bullet"><list-item>
      <p id="d2e4126">Replace all moving and electrical parts, including power supplies. ANSTO can assist with this service or provide instructions.</p></list-item></list></p>
</sec>
<sec id="Ch1.S5.SS2">
  <label>5.2</label><title>Instrument calibration and background</title>
      <p id="d2e4137">By default, the user specifies a schedule for instrument calibration and background checks. From a meteorological perspective, the calibration events will occur randomly. Each year, some calibrations will occur under conditions that closely satisfy the assumptions of the calibration process. Only these events should be retained.</p>
      <p id="d2e4140">Alternatively, background events can still be scheduled on an automatic regular basis, but the calibrations can be remotely triggered every 1–2 months, according to forecast meteorological conditions better meeting the assumptions of the calibration process. Automatic background checks will not account for any self-generation of radon inside the detector by trace amounts of <sup>226</sup>Ra. To ensure continuity in the case of software crashes or other issues, it is recommended to schedule background events to run automatically on a 2-monthly basis.</p>
      <p id="d2e4152">To achieve the lowest possible calibration uncertainty, a mobile calibration transfer standard device can be moved to the site once per year to run in parallel with the 1500 L radon detector for around 2 weeks to transfer a traceable calibration and instrumental background. The transferred background will account for self-generation of radon inside the detector by trace amounts of <sup>226</sup>Ra. Information about the availability of these transfer standard instruments can be obtained by contacting radon@ansto.gov.au.</p>
</sec>
<sec id="Ch1.S5.SS3">
  <label>5.3</label><title>Software</title>
      <p id="d2e4172">For Windows 10 operating systems and higher the Visual Basic version of the RDM control software has been increasingly unstable. For these systems, or to operate the software from a Unix/Linux platform, we recommend moving to the Python-based version of RDM <xref ref-type="bibr" rid="bib1.bibx29" id="paren.58"/>. Additional features of the Python-based control software include access to raw 10 s output of all detector parameters (as well as the 30 min averages), access to a log of all system messages and error messages, and access to a comprehensive log of all operational parameters of the calibration unit (if using a compressed-air Bürkert calibration system).</p>
      <p id="d2e4178">Graphical radon data processing software to perform all procedures described in Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/> on the 30 min instrument output apart from the deconvolution process was developed (available upon request). The software was currently developed and tested under Windows 10 or higher platforms.</p>
</sec>
<sec id="Ch1.S5.SS4">
  <label>5.4</label><title>Quality health workflow</title>
      <p id="d2e4191">A three-stage data quality control regime is recommended. <list list-type="bullet"><list-item>
      <p id="d2e4196"><italic>Monthly</italic>. New data files should be checked for time-stamping errors (missing, partial, or duplicate records) and data flagged if key diagnostic parameters are out of range (Table <xref ref-type="table" rid="Ch1.T1"/>).</p></list-item><list-item>
      <p id="d2e4204"><italic>Quarterly</italic>. Monthly calibrations and quarterly background checks should be processed and reviewed, and if feasible fitting should be conducted.</p></list-item><list-item>
      <p id="d2e4210"><italic>6-month (final data product)</italic>. The 6-month fitted calibration coefficient and instrumental background are reviewed, along with the executing of deconvolution code and STP correction, to derive the best estimate of radon concentration together with associated uncertainties. At this stage, it is recommended that a simultaneous review of data from multiple sites be conducted. This approach enables comprehensive analysis and comparison, facilitating the identification of any anomalies or inconsistencies that may require further investigation.</p></list-item></list></p>
</sec>
<sec id="Ch1.S5.SS5">
  <label>5.5</label><title>Data levels for dissemination</title>
      <p id="d2e4224">Data obtained from ANSTO two-filter radon detectors can be disseminated across various temporal scales, including near-real-time (level 1) and 6-month (level 1) or long-term intervals. Each temporal scale is associated with different relative uncertainties, which should be clearly documented in the metadata. To process raw counts into radon concentrations, aside from response time correction, it is necessary to remove background counts and apply calibration. Both the background count and the calibration coefficient can be modelled, with the accuracy and complexity of these models varying based on the available data.</p>
      <p id="d2e4227">When a detector is first commissioned, initial estimates of the calibration coefficient and instrumental background count are determined. These values serve as constants for deriving near-real-time radon concentrations during the first 6 months of operation. Subsequently, the calibration and background history is reviewed, and fitted values for the next 6 months are derived. To update the calibration coefficient and instrumental background for the subsequent month (e.g. month 7), the last value from the fitting is utilized. It is noteworthy that the commissioning background check may involve thoron contamination and may need to be disregarded. For near-real-time measurements, deconvolution can be run routinely, with the code taking about 1 min to process 1 d of data. Deconvolution is then re-run in post-processing after the finalization of the calibration coefficients and background count rate time series.</p>
      <p id="d2e4230">The availability of level 1 data on a 6-monthly basis is highly desirable for  modellers, particularly for evaluating operational data model integration, in this case employing radon to assess the accuracy of ATMs. Implementing a routine and operational radon approach facilitates the ongoing assessment of the accuracy of these transport models, thereby enhancing the accuracy of GHG emission estimates.</p>
      <p id="d2e4233">After 1 full year of measurements are available, the consistency and seasonality of calibration factors can be assessed and a representative average value calculated for the year. The available background checks can be assessed for consistency and a linear model applied. This year of data should be processed with this information and archived, and this calibration factor and background model should then be used to generate the “near-real-time” data for the subsequent year of measurements. This process is complete after 5 years when the detector's measurement head is replaced, and the process starts again.</p>
      <p id="d2e4237">Data from the UK radon network are stored at the Centre for Environmental Data Analysis (CEDA), while data from the ICOS network may be made accessible through the ICOS portal; additionally, GAW/WMO radon data can be archived and made available at the World Data Centre for Greenhouse Gases (WDCGG).</p>
</sec>
</sec>
<sec id="Ch1.S6" sec-type="conclusions">
  <label>6</label><title>Conclusions</title>
      <p id="d2e4249">In this study, we have developed a comprehensive protocol to enhance the reliability of reported radon activity concentrations for near-real-time applications, enabling their direct comparison to GHG measurements within a monitoring network of three independently managed observatories in the UK.</p>
      <p id="d2e4252">Our protocol emphasizes the importance of achieving radon measurements with accuracy and resolution comparable to GHGs, necessitating specific procedures for quality control, calibration, deconvolution, and uncertainty assignment. Validation of this protocol through meticulous analysis of calibration events and comparison with GHG measurements establishes a foundation for standardizing protocols across networks (ICOS and GAW) using two-filter instruments to measure radon.</p>
      <p id="d2e4255">The critical role of deconvolution in preserving the true signal of radon, particularly for quantitative tracer applications in atmospheric studies, is underscored. Our analysis demonstrates the adaptability of the deconvolution technique across seasonal variations and distinct atmospheric dynamics, ensuring accuracy in tracking GHG trends across all sites and validating ATM outputs. Synchronization of radon peaks with GHGs, especially during summer diurnal variations, further validates the effectiveness of our deconvolution method in real-world conditions, highlighting radon's importance as a tracer in understanding atmospheric mixing.</p>
      <p id="d2e4258">This study offers a robust protocol for radon measurement within GHG monitoring networks and underscores the invaluable role of radon as an independent metric in ATMs. By ensuring the accuracy and comparability of radon measurements, it may contribute to refining GHG emissions estimates and improving understanding of atmospheric processes, and it could be a significant contribution to climate change mitigation and the achievement of the Paris Agreement.</p>
</sec>

      
      </body>
    <back><app-group>

<app id="App1.Ch1.S1">
  <label>Appendix A</label><title/>

<table-wrap id="App1.Ch1.S1.T3"><label>Table A1</label><caption><p id="d2e4274">Site-specific radon source strength (Pylon 2000A <sup>226</sup>Ra).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="2">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Site</oasis:entry>
         <oasis:entry colname="col2">Source strength</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">(kBq)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">TAC</oasis:entry>
         <oasis:entry colname="col2">49.138</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">RGL</oasis:entry>
         <oasis:entry colname="col2">49.197</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">HFD</oasis:entry>
         <oasis:entry colname="col2">49.311</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">WAO</oasis:entry>
         <oasis:entry colname="col2">41.822</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

<table-wrap id="App1.Ch1.S1.T4"><label>Table A2</label><caption><p id="d2e4359">Summary of dual-flow-loop two-filter radon detector outputs, description, and units.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="justify" colwidth="8.5cm"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Detector output</oasis:entry>
         <oasis:entry colname="col2">Description</oasis:entry>
         <oasis:entry colname="col3">Unit</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">(parameters)</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">date</oasis:entry>
         <oasis:entry colname="col2">time stamp represents the end of measurement interval</oasis:entry>
         <oasis:entry colname="col3">dd mm yy hh:mm:ss</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">external_flow</oasis:entry>
         <oasis:entry colname="col2">moves sampled air from intake point, inlet pipe, thoron delay, and primary filter into the detector delay volume and out of exhaust valve</oasis:entry>
         <oasis:entry colname="col3">L min<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">internal_flow</oasis:entry>
         <oasis:entry colname="col2">circulates sampled air from the enclosure containing both blowers, through the flow-homogenizing denim screen, down the length of the delay volume, through the detector head and secondary filter, along the central pipe, and back to the blower enclosure</oasis:entry>
         <oasis:entry colname="col3">m s<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">LLD</oasis:entry>
         <oasis:entry colname="col2">lower level of discrimination</oasis:entry>
         <oasis:entry colname="col3">count (30 min)<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">ULD</oasis:entry>
         <oasis:entry colname="col2">upper level of discrimination</oasis:entry>
         <oasis:entry colname="col3">count (30 min)<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">differential_press</oasis:entry>
         <oasis:entry colname="col2">differential pressure between the detector tank and ambient air</oasis:entry>
         <oasis:entry colname="col3">mV</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">logger_temp</oasis:entry>
         <oasis:entry colname="col2">temperature inside the logger</oasis:entry>
         <oasis:entry colname="col3">°C</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">detector_temp</oasis:entry>
         <oasis:entry colname="col2">temperature inside the detector tank</oasis:entry>
         <oasis:entry colname="col3">°C</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">detector_RH</oasis:entry>
         <oasis:entry colname="col2">relative humidity inside the detector tank</oasis:entry>
         <oasis:entry colname="col3">%</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">detector_press</oasis:entry>
         <oasis:entry colname="col2">absolute pressure inside the detector tank</oasis:entry>
         <oasis:entry colname="col3">hPa</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">voltage</oasis:entry>
         <oasis:entry colname="col2">photomultiplier, high voltage</oasis:entry>
         <oasis:entry colname="col3">V</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">bg_lld</oasis:entry>
         <oasis:entry colname="col2">instrumental background</oasis:entry>
         <oasis:entry colname="col3">count (30 min)<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">cal_coeff</oasis:entry>
         <oasis:entry colname="col2">monthly calibration coefficient</oasis:entry>
         <oasis:entry colname="col3">count s<sup>−1</sup> (Bq m<sup>−3</sup>)<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">bg_lld_inter</oasis:entry>
         <oasis:entry colname="col2">6-month interpolated background</oasis:entry>
         <oasis:entry colname="col3">count (30 min)<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">cal_coeff_inter</oasis:entry>
         <oasis:entry colname="col2">6-month interpolated calibration</oasis:entry>
         <oasis:entry colname="col3">count s<sup>−1</sup> (Bq m<sup>−3</sup>)<sup>−1</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">radon_initial</oasis:entry>
         <oasis:entry colname="col2">calibrated radon activity concentration based on LLD, calibration, and background-interpolated value</oasis:entry>
         <oasis:entry colname="col3">Bq m<sup>−3</sup></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">radon</oasis:entry>
         <oasis:entry colname="col2">deconvolved calibrated radon activity concentration corrected for standard temperature and pressure (best estimate of radon activity concentration)</oasis:entry>
         <oasis:entry colname="col3">Bq m<sup>−3</sup> (STP)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">radon_uncertainty</oasis:entry>
         <oasis:entry colname="col2">combined uncertainties</oasis:entry>
         <oasis:entry colname="col3">Bq m<sup>−3</sup> (STP)</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>


</app>
  </app-group><notes notes-type="codedataavailability"><title>Code and data availability</title>

      <p id="d2e4797">The graphical radon data processing software described in Sect. <xref ref-type="sec" rid="Ch1.S5.SS3"/> is available upon request. The runtime script for the Python-based research package used for this study is available upon request. Software for logging radon detector output (<ext-link xlink:href="https://doi.org/10.5281/zenodo.14504311" ext-link-type="DOI">10.5281/zenodo.14504311</ext-link>, <xref ref-type="bibr" rid="bib1.bibx29" id="altparen.59"/>), for implementing the deconvolution algorithm (<ext-link xlink:href="https://doi.org/10.5281/zenodo.14503937" ext-link-type="DOI">10.5281/zenodo.14503937</ext-link>, <xref ref-type="bibr" rid="bib1.bibx30" id="altparen.60"/>), and for simulating the detector response during calibration cycles (<ext-link xlink:href="https://doi.org/10.5281/zenodo.14504261" ext-link-type="DOI">10.5281/zenodo.14504261</ext-link>, <xref ref-type="bibr" rid="bib1.bibx28" id="altparen.61"/>) is released under open-source licenses and is freely available. The fitting algorithm described in Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/> is available in the Supplement. Radon and GHG data from the UK DECC network sites, Heathfield and Tacolneston, are accessible through the Centre for Environmental Data Analysis (CEDA) at <ext-link xlink:href="https://doi.org/10.5285/bd7164851bcc491b912f9d650fcf7981" ext-link-type="DOI">10.5285/bd7164851bcc491b912f9d650fcf7981</ext-link> <xref ref-type="bibr" rid="bib1.bibx54" id="paren.62"/>. Radon and GHG data from the Weybourne Atmospheric Observatory are available through CEDA at <uri>https://data.ceda.ac.uk/badc/ncas-wao/data/uea-radon-1/20180321_longterm/v1.0</uri> <xref ref-type="bibr" rid="bib1.bibx23" id="paren.63"/> and <uri>https://data.ceda.ac.uk/badc/ncas-wao/data/ncas-ftir-1/20170801_longterm/v3.0</uri> <xref ref-type="bibr" rid="bib1.bibx21" id="paren.64"/>, respectively.</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d2e4842">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/amt-18-151-2025-supplement" xlink:title="zip">https://doi.org/10.5194/amt-18-151-2025-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d2e4851">DK led the research design, performed all data visualizations, and developed the concepts and results. The development of a standardized protocol was a joint effort by DK, EC, SDC, ADG, TA, GF, and AW. Radon measurements and calibration at HFD were conducted by DK, at WAO by GF, and at TAC by AW. EC developed the software for radon quality control, performing data checks and deconvolution across all sites, with support from DK, AW, GF, and ADG. GHG measurement responsibilities were divided as follows: TA, CR, ES, and DK for HFD; GF, LSF, PP, and KA for WAO; and SO'D, JP, DY, KS, and AW for TAC. DK wrote the complete original draft of the paper, with SDC, ADG, PP, AW, EC, JP, CR, and TA contributing to the editing and review process.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d2e4857">At least one of the (co-)authors is a member of the editorial board of <italic>Atmospheric Measurement Techniques</italic>. The peer-review process was guided by an independent editor, and the authors also have no other competing interests to declare.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d2e4866">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.</p>
  </notes><ack><title>Acknowledgements</title><p id="d2e4872">The authors thank Andrew Manning and Alex Etchells (both University of East Anglia) for maintaining the CO<sub>2</sub> measurement system at WAO and Ot Sisoutham of ANSTO for construction and initial testing of all two-filter radon detectors used in this study.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d2e4887">This research has been supported by the NPL Directors' Fund, National Measurement System Funding, and the NERC – Building a Green Future: GEMMA Greenhouse Gas Emissions Measurement and Modelling Advancement project (grant no. NE/Y001788/1). The ANSTO radon detectors for this work and the Picarro G5310 at HFD were purchased with the UKRI NERC grant “Advanced UK Observing Network For Air Quality, Public Heath and Greenhouse Gas Research” (grant no. NE/R011532/1) in 2018, awarded to the University of Edinburgh, University of Bristol, and University of East Anglia.​​​​​​​</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d2e4893">This paper was edited by David Griffith and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Adcock et al.(2023)</label><mixed-citation>Adcock, K. E., Pickers, P. A., Manning, A. C., Forster, G. L., Fleming, L. S., Barningham, T., Wilson, P. A., Kozlova, E. A., Hewitt, M., Etchells, A. J., and Macdonald, A. J.: 12 years of continuous atmospheric O<sub>2</sub>, CO<sub>2</sub> and APO data from Weybourne Atmospheric Observatory in the United Kingdom, Earth Syst. Sci. Data, 15, 5183–5206, <ext-link xlink:href="https://doi.org/10.5194/essd-15-5183-2023" ext-link-type="DOI">10.5194/essd-15-5183-2023</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Alduchov and Eskridge(1996)</label><mixed-citation> Alduchov, O. A. and Eskridge, R. E.: Improved Magnus form approximation of saturation vapor pressure, J. Appl. Meteorol., 35, 601–609, 1996.​​​​​​​</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Arnold et al.(2018)</label><mixed-citation>Arnold, T., Manning, A. J., Kim, J., Li, S., Webster, H., Thomson, D., Mühle, J., Weiss, R. F., Park, S., and O'Doherty, S.: Inverse modelling of CF<sub>4</sub> and NF<sub>3</sub> emissions in East Asia, Atmos. Chem. Phys., 18, 13305–13320, <ext-link xlink:href="https://doi.org/10.5194/acp-18-13305-2018" ext-link-type="DOI">10.5194/acp-18-13305-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Baker et al.(2006)</label><mixed-citation>Baker, D. F., Law, R. M., Gurney, K. R., Rayner, P., Peylin, P., Denning, A. S., Bousquet, P., Bruhwiler, L., Chen, Y.-H., Ciais, P., Fung, I. Y., Heimann, M., John, J., Maki, T., Maksyutov, S., Masarie, K., Prather, M., Pak, B., Taguchi, S., and Zhu, Z.: TransCom 3 inversion intercomparison: Impact of transport model errors on the interannual variability of regional CO<sub>2</sub> fluxes, 1988–2003, Global Biogeochem. Cy., 20, GB1002, <ext-link xlink:href="https://doi.org/10.1029/2004GB002439" ext-link-type="DOI">10.1029/2004GB002439</ext-link>, 2006.​​​​​​​</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Bergamaschi et al.(2015)</label><mixed-citation>Bergamaschi, P., Corazza, M., Karstens, U., Athanassiadou, M., Thompson, R. L., Pison, I., Manning, A. J., Bousquet, P., Segers, A., Vermeulen, A. T., Janssens-Maenhout, G., Schmidt, M., Ramonet, M., Meinhardt, F., Aalto, T., Haszpra, L., Moncrieff, J., Popa, M. E., Lowry, D., Steinbacher, M., Jordan, A., O'Doherty, S., Piacentino, S., and Dlugokencky, E.: Top-down estimates of European CH<sub>4</sub> and N<sub>2</sub>O emissions based on four different inverse models, Atmos. Chem. Phys., 15, 715–736, <ext-link xlink:href="https://doi.org/10.5194/acp-15-715-2015" ext-link-type="DOI">10.5194/acp-15-715-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Bergamaschi et al.(2018)</label><mixed-citation>Bergamaschi, P., Karstens, U., Manning, A. J., Saunois, M., Tsuruta, A., Berchet, A., Vermeulen, A. T., Arnold, T., Janssens-Maenhout, G., Hammer, S., Levin, I., Schmidt, M., Ramonet, M., Lopez, M., Lavric, J., Aalto, T., Chen, H., Feist, D. G., Gerbig, C., Haszpra, L., Hermansen, O., Manca, G., Moncrieff, J., Meinhardt, F., Necki, J., Galkowski, M., O'Doherty, S., Paramonova, N., Scheeren, H. A., Steinbacher, M., and Dlugokencky, E.: Inverse modelling of European CH<sub>4</sub> emissions during 2006–2012 using different inverse models and reassessed atmospheric observations, Atmos. Chem. Phys., 18, 901–920, <ext-link xlink:href="https://doi.org/10.5194/acp-18-901-2018" ext-link-type="DOI">10.5194/acp-18-901-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Biraud et al.(2000)</label><mixed-citation>Biraud, S., Ciais, P., Ramonet, M., Simmonds, P., Kazan, V., Monfray, P., O'Doherty, S., Spain, T. G., and Jennings, S. G.: European greenhouse gas emissions estimated from continuous atmospheric measurements and radon 222 at Mace Head, Ireland, J. Geophys. Res.-Atmos., 105, 1351–1366, <ext-link xlink:href="https://doi.org/10.1029/1999JD900821" ext-link-type="DOI">10.1029/1999JD900821</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Brown et al.(2023)</label><mixed-citation>Brown, P., Cardenas, L., Del Vento, S., Karagianni, E., MacCarthy, J., Mullen, P., Passant, N., Richmond, B., Thistlethwaite, G., Thomson, A., Wakeling, D., and Willis, D.: UK greenhouse gas inventory, 1990 to 2021: annual report for submission under the Framework Convention on Climate Change, Ricardo Energy &amp; Environment, ISBN 9780993397592, 601 pp., <ext-link xlink:href="https://naei.energysecurity.gov.uk/reports/uk-greenhouse-gas-inventory-1990-2022-annual-report-submission-under-framework-convention">https://naei.energysecurity.gov.uk/reports/uk-greenhouse-gas-inventory-1990-2022-annual-report-submission-under-framework-convention</ext-link> (last access: 12 January 2025), 2024.​​​​​​​</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Chambers et al.(2011)</label><mixed-citation>Chambers, S., Williams, A. G., Zahorowski, W., Griffiths, A., and Crawford, J.: Separating remote fetch and local mixing influences on vertical radon measurements in the lower atmosphere, Tellus B, 63, 843–859, <ext-link xlink:href="https://doi.org/10.1111/j.1600-0889.2011.00565.x" ext-link-type="DOI">10.1111/j.1600-0889.2011.00565.x</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Chambers et al.(2015)</label><mixed-citation>Chambers, S. D., Williams, A. G., Crawford, J., and Griffiths, A. D.: On the use of radon for quantifying the effects of atmospheric stability on urban emissions, Atmos. Chem. Phys., 15, 1175–1190, <ext-link xlink:href="https://doi.org/10.5194/acp-15-1175-2015" ext-link-type="DOI">10.5194/acp-15-1175-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Chambers et al.(2016)</label><mixed-citation>Chambers, S. D., Williams, A. G., Conen, F., Griffiths, A. D., Reimann, S., Steinbacher, M., Krummel, P. B., Steele, L. P., Schoot, M. V. V. D., Galbally, I. E., Molloy, S. B., and Barnes, J. E.: Towards a Universal “Baseline” Characterisation of Air Masses for High- and Low-Altitude Observing Stations Using Radon-222, Aerosol Air Qual. Res., 16, 885–899, <ext-link xlink:href="https://doi.org/10.4209/aaqr.2015.06.0391" ext-link-type="DOI">10.4209/aaqr.2015.06.0391</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Chambers et al.(2019a)</label><mixed-citation>Chambers, S. D., Guérette, E.-A., Monk, K., Griffiths, A. D., Zhang, Y., Duc, H., Cope, M., Emmerson, K. M., Chang, L. T., Silver, J. D., Utembe, S., Crawford, J., Williams, A. G., and Keywood, M.: Skill-Testing Chemical Transport Models across Contrasting Atmospheric Mixing States Using Radon-222, Atmosphere, 10, 25, <ext-link xlink:href="https://doi.org/10.3390/atmos10010025" ext-link-type="DOI">10.3390/atmos10010025</ext-link>, 2019a.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Chambers et al.(2019b)</label><mixed-citation>Chambers, S. D., Podstawczyńska, A., Pawlak, W., Fortuniak, K., Williams, A. G., and Griffiths, A. D.: Characterizing the State of the Urban Surface Layer Using Radon-222, J. Geophys. Res.-Atmos., 124, 770–788, <ext-link xlink:href="https://doi.org/10.1029/2018JD029507" ext-link-type="DOI">10.1029/2018JD029507</ext-link>, 2019b.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Chambers et al.(2022)</label><mixed-citation>Chambers, S. D., Griffiths, A. D., Williams, A. G., Sisoutham, O., Morosh, V., Röttger, S., Mertes, F., and Röttger, A.: Portable two-filter dual-flow-loop <sup>222</sup>Rn detector: stand-alone monitor and calibration transfer device, Adv. Geosci., 57, 63–80, <ext-link xlink:href="https://doi.org/10.5194/adgeo-57-63-2022" ext-link-type="DOI">10.5194/adgeo-57-63-2022</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Chevillard et al.(2002)</label><mixed-citation>Chevillard, A., Ciais, P., Karstens, U., Heimann, M., Schmidt, M., Levin, I., Jacob, D., Podzun, R., Kazan, V., Sartorius, H., and Weingartner, E.: Transport of <sup>222</sup>Rn using the regional model REMO: a detailed comparison with measurements over Europe, Tellus B, 54, 850–871, <ext-link xlink:href="https://doi.org/10.3402/tellusb.v54i5.16735" ext-link-type="DOI">10.3402/tellusb.v54i5.16735</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Ciais et al.(2014)</label><mixed-citation>Ciais, P., Dolman, A. J., Bombelli, A., Duren, R., Peregon, A., Rayner, P. J., Miller, C., Gobron, N., Kinderman, G., Marland, G., Gruber, N., Chevallier, F., Andres, R. J., Balsamo, G., Bopp, L., Bréon, F.-M., Broquet, G., Dargaville, R., Battin, T. J., Borges, A., Bovensmann, H., Buchwitz, M., Butler, J., Canadell, J. G., Cook, R. B., DeFries, R., Engelen, R., Gurney, K. R., Heinze, C., Heimann, M., Held, A., Henry, M., Law, B., Luyssaert, S., Miller, J., Moriyama, T., Moulin, C., Myneni, R. B., Nussli, C., Obersteiner, M., Ojima, D., Pan, Y., Paris, J.-D., Piao, S. L., Poulter, B., Plummer, S., Quegan, S., Raymond, P., Reichstein, M., Rivier, L., Sabine, C., Schimel, D., Tarasova, O., Valentini, R., Wang, R., van der Werf, G., Wickland, D., Williams, M., and Zehner, C.: Current systematic carbon-cycle observations and the need for implementing a policy-relevant carbon observing system, Biogeosciences, 11, 3547–3602, <ext-link xlink:href="https://doi.org/10.5194/bg-11-3547-2014" ext-link-type="DOI">10.5194/bg-11-3547-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Crotwell et al.(2017)</label><mixed-citation>Crotwell, A., Steinbacher, M., World Meteorological Organization (WMO)​​​​​​​, and 19th WMO/IAEA Meeting on Carbon Dioxide: 19th WMO/IAEA Meeting on Carbon Dioxide, Other Greenhouse Gases and Related Measurement Techniques (GGMT-2017), Dübendorf, Switzerland, 27–31 August 2017, Tech. rep., WMO, <ext-link xlink:href="https://library.wmo.int/records/item/37000-19th-wmo-iaea-meeting-on-carbon-dioxide-other-greenhouse-gases-and-related-measurement-techniques-ggmt-2017#.Xmdl6Oko9rk">https://library.wmo.int/records/item/37000-19th-wmo-iaea-meeting-on-carbon-dioxide-other-greenhouse-gases-and-related-measurement-techniques-ggmt-2017#.Xmdl6Oko9rk</ext-link> (last access: 20 December 2024), 2017.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Dentener et al.(1999)</label><mixed-citation>Dentener, F., Feichter, J., and Jeuken, A.: Simulation of the transport of <sup>222</sup>Rn using on-line and off-line global models at different horizontal resolutions: a detailed comparison with measurements, Tellus B, 51, 573–602, <ext-link xlink:href="https://doi.org/10.3402/tellusb.v51i3.16440" ext-link-type="DOI">10.3402/tellusb.v51i3.16440</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>Eve(1908)</label><mixed-citation>Eve, A.: LI. On the amount of radium emanation in the atmosphere near the earth's surface, London Edinburgh Philos. Mag. &amp; J. Sci., 16, 622–632, <ext-link xlink:href="https://doi.org/10.1080/14786441008636540" ext-link-type="DOI">10.1080/14786441008636540</ext-link>, 1908.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Fleming et al.(2012)</label><mixed-citation>Fleming, Z. L., Monks, P. S., and Manning, A. J.: Review: Untangling the influence of air-mass history in interpreting observed atmospheric composition, Atmos. Res., 104–105, 1–39, <ext-link xlink:href="https://doi.org/10.1016/j.atmosres.2011.09.009" ext-link-type="DOI">10.1016/j.atmosres.2011.09.009</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Forster(2024)</label><mixed-citation>Forster, G.: Weybourne Atmospheric Observatory, NERC EDS Centre for Environmental Data Analysis [data set], <uri>https://data.ceda.ac.uk/badc/ncas-wao/data/ncas-ftir-1/20170801_longterm/v3.0</uri> (last access: 13 January 2025), 2024.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Forster et al.(2012)</label><mixed-citation>Forster, G. L., Sturges, W. T., Fleming, Z. L., Bandy, B. J., and Emeis, S.: A year of H<sub>2</sub> measurements at Weybourne Atmospheric Observatory, UK, Tellus B, 64, 17771, <ext-link xlink:href="https://doi.org/10.3402/tellusb.v64i0.17771" ext-link-type="DOI">10.3402/tellusb.v64i0.17771</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Forster et al.(2024)</label><mixed-citation>Forster, G., Chung, E., and Kikaj, D.: Weybourne Atmospheric Observatory,  NERC EDS Centre for Environmental Data Analysis [data set], <uri>https://data.ceda.ac.uk/badc/ncas-wao/data/uea-radon-1/20180321_longterm/v1.0</uri> (last access: 13 January 2025), 2024.</mixed-citation></ref>
      <ref id="bib1.bibx24"><label>Galmarini(2006)</label><mixed-citation>Galmarini, S.: One year of <sup>222</sup>Rn concentration in the atmospheric surface layer, Atmos. Chem. Phys., 6, 2865–2886, <ext-link xlink:href="https://doi.org/10.5194/acp-6-2865-2006" ext-link-type="DOI">10.5194/acp-6-2865-2006</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Ganesan et al.(2015)</label><mixed-citation>Ganesan, A. L., Manning, A. J., Grant, A., Young, D., Oram, D. E., Sturges, W. T., Moncrieff, J. B., and O'Doherty, S.: Quantifying methane and nitrous oxide emissions from the UK and Ireland using a national-scale monitoring network, Atmos. Chem. Phys., 15, 6393–6406, <ext-link xlink:href="https://doi.org/10.5194/acp-15-6393-2015" ext-link-type="DOI">10.5194/acp-15-6393-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Geels et al.(2007)</label><mixed-citation>Geels, C., Gloor, M., Ciais, P., Bousquet, P., Peylin, P., Vermeulen, A. T., Dargaville, R., Aalto, T., Brandt, J., Christensen, J. H., Frohn, L. M., Haszpra, L., Karstens, U., Rödenbeck, C., Ramonet, M., Carboni, G., and Santaguida, R.: Comparing atmospheric transport models for future regional inversions over Europe – Part 1: mapping the atmospheric CO<sub>2</sub> signals, Atmos. Chem. Phys., 7, 3461–3479, <ext-link xlink:href="https://doi.org/10.5194/acp-7-3461-2007" ext-link-type="DOI">10.5194/acp-7-3461-2007</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Gerbig et al.(2008)</label><mixed-citation>Gerbig, C., Körner, S., and Lin, J. C.: Vertical mixing in atmospheric tracer transport models: error characterization and propagation, Atmos. Chem. Phys., 8, 591–602, <ext-link xlink:href="https://doi.org/10.5194/acp-8-591-2008" ext-link-type="DOI">10.5194/acp-8-591-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx28"><label>Griffiths(2024a)</label><mixed-citation>Griffiths, A.: anstoradonlab/radcalsim: Radon detector calibration simulator, Zenodo [code], <ext-link xlink:href="https://doi.org/10.5281/zenodo.14504261" ext-link-type="DOI">10.5281/zenodo.14504261</ext-link>, 2024a.</mixed-citation></ref>
      <ref id="bib1.bibx29"><label>Griffiths(2024b)</label><mixed-citation>Griffiths, A.: anstoradonlab/radon-monitor: RDM 10.17.2, Zenodo [code], <ext-link xlink:href="https://doi.org/10.5281/zenodo.14504311" ext-link-type="DOI">10.5281/zenodo.14504311</ext-link>, 2024b.</mixed-citation></ref>
      <ref id="bib1.bibx30"><label>Griffiths(2024c)</label><mixed-citation>Griffiths, A.: anstoradonlab/rdfix: v0.4.1, Zenodo [code], <ext-link xlink:href="https://doi.org/10.5281/zenodo.14503937" ext-link-type="DOI">10.5281/zenodo.14503937</ext-link>, 2024c.</mixed-citation></ref>
      <ref id="bib1.bibx31"><label>Griffiths et al.(2016)</label><mixed-citation>Griffiths, A. D., Chambers, S. D., Williams, A. G., and Werczynski, S.: Increasing the accuracy and temporal resolution of two-filter radon–222 measurements by correcting for the instrument response, Atmos. Meas. Tech., 9, 2689–2707, <ext-link xlink:href="https://doi.org/10.5194/amt-9-2689-2016" ext-link-type="DOI">10.5194/amt-9-2689-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx32"><label>Grossi et al.(2012)</label><mixed-citation>Grossi, C., Arnold, D., Adame, J. A., López-Coto, I., Bolívar, J. P., de la Morena, B. A., and Vargas, A.: Atmospheric <sup>222</sup>Rn concentration and source term at El Arenosillo 100 m meteorological tower in southwest Spain, Radiat. Meas., 47, 149–162, <ext-link xlink:href="https://doi.org/10.1016/j.radmeas.2011.11.006" ext-link-type="DOI">10.1016/j.radmeas.2011.11.006</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx33"><label>Grossi et al.(2018)</label><mixed-citation>Grossi, C., Vogel, F. R., Curcoll, R., Àgueda, A., Vargas, A., Rodó, X., and Morguí, J.-A.: Study of the daily and seasonal atmospheric CH<sub>4</sub> mixing ratio variability in a rural Spanish region using <sup>222</sup>Rn tracer, Atmos. Chem. Phys., 18, 5847–5860, <ext-link xlink:href="https://doi.org/10.5194/acp-18-5847-2018" ext-link-type="DOI">10.5194/acp-18-5847-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx34"><label>Grossi et al.(2020)</label><mixed-citation>Grossi, C., Chambers, S. D., Llido, O., Vogel, F. R., Kazan, V., Capuana, A., Werczynski, S., Curcoll, R., Delmotte, M., Vargas, A., Morguí, J.-A., Levin, I., and Ramonet, M.: Intercomparison study of atmospheric <sup>222</sup>Rn and <sup>222</sup>Rn progeny monitors, Atmos. Meas. Tech., 13, 2241–2255, <ext-link xlink:href="https://doi.org/10.5194/amt-13-2241-2020" ext-link-type="DOI">10.5194/amt-13-2241-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx35"><label>Gurney et al.(2016)</label><mixed-citation>Gurney, K. R., Huang, J., and Coltin, K.: Bias present in US federal agency power plant CO<sub>2</sub> emissions data and implications for the US clean power plan, Environ. Res. Lett., 11, 064005, <ext-link xlink:href="https://doi.org/10.1088/1748-9326/11/6/064005" ext-link-type="DOI">10.1088/1748-9326/11/6/064005</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx36"><label>Hammer et al.(2013)</label><mixed-citation>Hammer, S., Griffith, D. W. T., Konrad, G., Vardag, S., Caldow, C., and Levin, I.: Assessment of a multi-species in situ FTIR for precise atmospheric greenhouse gas observations, Atmos. Meas. Tech., 6, 1153–1170, <ext-link xlink:href="https://doi.org/10.5194/amt-6-1153-2013" ext-link-type="DOI">10.5194/amt-6-1153-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx37"><label>Hirao et al.(2008)</label><mixed-citation>Hirao, S., Yamazawa, H., Moriizumi, J., Yoshioka, K., and Iida, T.: Development and verification of long-range atmospheric Radon-222 transport model, J. Nucl. Sci. Technol., 45, 166–172, <ext-link xlink:href="https://doi.org/10.1080/00223131.2008.10876001" ext-link-type="DOI">10.1080/00223131.2008.10876001</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx38"><label>Hirsch(2007)</label><mixed-citation>Hirsch, A. I.: On using radon-222 and CO<sub>2</sub> to calculate regional-scale CO<sub>2</sub> fluxes, Atmos. Chem. Phys., 7, 3737–3747, <ext-link xlink:href="https://doi.org/10.5194/acp-7-3737-2007" ext-link-type="DOI">10.5194/acp-7-3737-2007</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx39"><label>Israël et al.(1966)</label><mixed-citation>Israël, H., Horbert, M., and Israël, G. W.: Results of continuous measurements of radon and its decay products in the lower atmosphere, Tellus, 18, 639–642, <ext-link xlink:href="https://doi.org/10.3402/tellusa.v18i2-3.9204" ext-link-type="DOI">10.3402/tellusa.v18i2-3.9204</ext-link>, 1966.</mixed-citation></ref>
      <ref id="bib1.bibx40"><label>Jacob et al.(1997)</label><mixed-citation>Jacob, D. J., Prather, M. J., Rasch, P. J., Shia, R.-L., Balkanski, Y. J., Beagley, S. R., Bergmann, D. J., Blackshear, W. T., Brown, M., Chiba, M., Chipperfield, M. P., de Grandpré, J., Dignon, J. E., Feichter, J., Genthon, C., Grose, W. L., Kasibhatla, P. S., Köhler, I., Kritz, M. A., Law, K., Penner, J. E., Ramonet, M., Reeves, C. E., Rotman, D. A., Stockwell, D. Z., Van Velthoven, P. F. J., Verver, G., Wild, O., Yang, H., and Zimmermann, P.: Evaluation and intercomparison of global atmospheric transport models using <sup>222</sup>Rn and other short-lived tracers, J. Geophys. Res.-Atmos., 102, 5953–5970, <ext-link xlink:href="https://doi.org/10.1029/96JD02955" ext-link-type="DOI">10.1029/96JD02955</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bibx41"><label>Kikaj et al.(2019)</label><mixed-citation>Kikaj, D., Vaupotič, J., and Chambers, S. D.: Identifying persistent temperature inversion events in a subalpine basin using radon-222, Atmos. Meas. Tech., 12, 4455–4477, <ext-link xlink:href="https://doi.org/10.5194/amt-12-4455-2019" ext-link-type="DOI">10.5194/amt-12-4455-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx42"><label>Kikaj et al.(2023)</label><mixed-citation>Kikaj, D., Chambers, S. D., Crawford, J., Kobal, M., Gregorič, A., and Vaupotič, J.: Investigating the vertical and spatial extent of radon-based classification of the atmospheric mixing state and impacts on seasonal urban air quality, Sci. Total Environ., 872, 162126, <ext-link xlink:href="https://doi.org/10.1016/j.scitotenv.2023.162126" ext-link-type="DOI">10.1016/j.scitotenv.2023.162126</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx43"><label>Lambert et al.(1970)</label><mixed-citation>Lambert, G., Polian, G., Taupin, D., and Lambert, R.: Existence of periodicity in radon concentrations and in the large-scale circulation at lower altitudes' between 40° and 70° South, J. Geophys. Res., 75, 2341–2345, <ext-link xlink:href="https://doi.org/10.1029/JC075i012p02341" ext-link-type="DOI">10.1029/JC075i012p02341</ext-link>, 1970.</mixed-citation></ref>
      <ref id="bib1.bibx44"><label>Levin(1987)</label><mixed-citation>Levin, I.: Atmospheric CO<sub>2</sub> in continental Europe – an alternative approach to clean air CO<sub>2</sub> data, Tellus B, 39B, 21–28, <ext-link xlink:href="https://doi.org/10.1111/j.1600-0889.1987.tb00267.x" ext-link-type="DOI">10.1111/j.1600-0889.1987.tb00267.x</ext-link>, 1987.</mixed-citation></ref>
      <ref id="bib1.bibx45"><label>Levin et al.(2002)</label><mixed-citation>Levin, I., Born, M., Cuntz, M., Langendörfer, U., Mantsch, S., Naegler, T., Schmidt, M., Varlagin, A., Verclas, S., and Wagenbach, D.: Observations of atmospheric variability and soil exhalation rate of radon-222 at a Russian forest site. Technical approach and deployment for boundary layer studies, Tellus B, 54, 462–475, <ext-link xlink:href="https://doi.org/10.1034/j.1600-0889.2002.01346.x" ext-link-type="DOI">10.1034/j.1600-0889.2002.01346.x</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx46"><label>Levin et al.(2021)</label><mixed-citation>Levin, I., Karstens, U., Hammer, S., DellaColetta, J., Maier, F., and Gachkivskyi, M.: Limitations of the radon tracer method (RTM) to estimate regional greenhouse gas (GHG) emissions – a case study for methane in Heidelberg, Atmos. Chem. Phys., 21, 17907–17926, <ext-link xlink:href="https://doi.org/10.5194/acp-21-17907-2021" ext-link-type="DOI">10.5194/acp-21-17907-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx47"><label>Liu et al.(2011)</label><mixed-citation>Liu, J., Fung, I., Kalnay, E., and Kang, J.-S.: CO<sub>2</sub> transport uncertainties from the uncertainties in meteorological fields, Geophys. Res. Lett., 38, L12808, <ext-link xlink:href="https://doi.org/10.1029/2011GL047213" ext-link-type="DOI">10.1029/2011GL047213</ext-link>, 2011.​​​​​​​</mixed-citation></ref>
      <ref id="bib1.bibx48"><label>Lunt et al.(2021)</label><mixed-citation>Lunt, M. F., Manning, A. J., Allen, G., Arnold, T., Bauguitte, S. J.-B., Boesch, H., Ganesan, A. L., Grant, A., Helfter, C., Nemitz, E., O'Doherty, S. J., Palmer, P. I., Pitt, J. R., Rennick, C., Say, D., Stanley, K. M., Stavert, A. R., Young, D., and Rigby, M.: Atmospheric observations consistent with reported decline in the UK's methane emissions (2013–2020), Atmos. Chem. Phys., 21, 16257–16276, <ext-link xlink:href="https://doi.org/10.5194/acp-21-16257-2021" ext-link-type="DOI">10.5194/acp-21-16257-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx49"><label>Mahowald et al.(1995)</label><mixed-citation>Mahowald, N. M., Rasch, P. J., and Prinn, R. G.: Cumulus parameterizations in chemical transport models, J. Geophys. Res.-Atmos., 100, 26173–26189, <ext-link xlink:href="https://doi.org/10.1029/95JD02606" ext-link-type="DOI">10.1029/95JD02606</ext-link>, 1995.</mixed-citation></ref>
      <ref id="bib1.bibx50"><label>Manning et al.(2011)</label><mixed-citation>Manning, A. J., O'Doherty, S., Jones, A. R., Simmonds, P. G., and Derwent, R. G.: Estimating UK methane and nitrous oxide emissions from 1990 to 2007 using an inversion modeling approach, J. Geophys. Res.-Atmos., 116, D02305, <ext-link xlink:href="https://doi.org/10.1029/2010JD014763" ext-link-type="DOI">10.1029/2010JD014763</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx51"><label>Manning et al.(2021)</label><mixed-citation>Manning, A. J., Redington, A. L., Say, D., O'Doherty, S., Young, D., Simmonds, P. G., Vollmer, M. K., Mühle, J., Arduini, J., Spain, G., Wisher, A., Maione, M., Schuck, T. J., Stanley, K., Reimann, S., Engel, A., Krummel, P. B., Fraser, P. J., Harth, C. M., Salameh, P. K., Weiss, R. F., Gluckman, R., Brown, P. N., Watterson, J. D., and Arnold, T.: Evidence of a recent decline in UK emissions of hydrofluorocarbons determined by the InTEM inverse model and atmospheric measurements, Atmos. Chem. Phys., 21, 12739–12755, <ext-link xlink:href="https://doi.org/10.5194/acp-21-12739-2021" ext-link-type="DOI">10.5194/acp-21-12739-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx52"><label>Munassar et al.(2023)</label><mixed-citation>Munassar, S., Monteil, G., Scholze, M., Karstens, U., Rödenbeck, C., Koch, F.-T., Totsche, K. U., and Gerbig, C.: Why do inverse models disagree? A case study with two European CO<sub>2</sub> inversions, Atmos. Chem. Phys., 23, 2813–2828, <ext-link xlink:href="https://doi.org/10.5194/acp-23-2813-2023" ext-link-type="DOI">10.5194/acp-23-2813-2023</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx53"><label>Nisbet and Weiss(2010)</label><mixed-citation>Nisbet, E. and Weiss, R.: Top-Down Versus Bottom-Up, Science, 328, 1241–1243, <ext-link xlink:href="https://doi.org/10.1126/science.1189936" ext-link-type="DOI">10.1126/science.1189936</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx54"><label>O'Doherty et al.(2024)</label><mixed-citation>O'Doherty, S., Arnold, T., Chung, E., Ganesan, A., Garrard, N., Grant, A., Kikaj, D., Pitt, J., Rennick, C., Safi, E., Say, D., Spain, G., Stanley, K., Stavert, A., Wenger, A., Wisher, A., and Young, D.: Atmospheric trace gas observations from the UK Deriving Emissions linked to Climate Change (DECC) Network and associated data – Version 24.09, NERC EDS Centre for Environmental Data Analysis [data set], <ext-link xlink:href="https://doi.org/10.5285/bd7164851bcc491b912f9d650fcf7981" ext-link-type="DOI">10.5285/bd7164851bcc491b912f9d650fcf7981</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bibx55"><label>Penkett et al.(1999)</label><mixed-citation>Penkett, S. A., Plane, J. M. C., Comes, F. J., Clemitshaw, K. C., and Coe, H.: The Weybourne Atmospheric Observatory, J. Atmos. Chem., 33, 107–110, <ext-link xlink:href="https://doi.org/10.1023/A:1026428102821" ext-link-type="DOI">10.1023/A:1026428102821</ext-link>, 1999.</mixed-citation></ref>
      <ref id="bib1.bibx56"><label>Pereira and Da Silva(1989)</label><mixed-citation>Pereira, E. B. and Da Silva, H. E.: Atmospheric radon measurements by electrostatic precipitation, Nucl. Instrum. Methods Phys. Res. A, 280, 503–505, <ext-link xlink:href="https://doi.org/10.1016/0168-9002(89)90960-1" ext-link-type="DOI">10.1016/0168-9002(89)90960-1</ext-link>, 1989.</mixed-citation></ref>
      <ref id="bib1.bibx57"><label>Perrino et al.(2001)</label><mixed-citation>Perrino, C., Pietrodangelo, A., and Febo, A.: An atmospheric stability index based on radon progeny measurements for the evaluation of primary urban pollution, Atmos. Environ., 35, 5235–5244, <ext-link xlink:href="https://doi.org/10.1016/S1352-2310(01)00349-1" ext-link-type="DOI">10.1016/S1352-2310(01)00349-1</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bibx58"><label>Polian et al.(1986)</label><mixed-citation>Polian, G., Lambert, G., Ardouin, B., and Jegou, A.: Long-range transport of continental radon in subantarctic and antarctic areas, Tellus B, 38, 178–189, <ext-link xlink:href="https://doi.org/10.3402/tellusb.v38i3-4.15126" ext-link-type="DOI">10.3402/tellusb.v38i3-4.15126</ext-link>, 1986.</mixed-citation></ref>
      <ref id="bib1.bibx59"><label>Röttger et al.(2023)</label><mixed-citation>Röttger, S., Röttger, A., Mertes, F., Morosch, V., Ballé, T., and Chambers, S.: Evolution of traceable radon emanation sources from MBq to few Bq, Appl. Radiat. Isot., 196, 110726, <ext-link xlink:href="https://doi.org/10.1016/j.apradiso.2023.110726" ext-link-type="DOI">10.1016/j.apradiso.2023.110726</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx60"><label>Schmithüsen et al.(2017)</label><mixed-citation>Schmithüsen, D., Chambers, S., Fischer, B., Gilge, S., Hatakka, J., Kazan, V., Neubert, R., Paatero, J., Ramonet, M., Schlosser, C., Schmid, S., Vermeulen, A., and Levin, I.: A European-wide <sup>222</sup>radon and <sup>222</sup>radon progeny comparison study, Atmos. Meas. Tech., 10, 1299–1312, <ext-link xlink:href="https://doi.org/10.5194/amt-10-1299-2017" ext-link-type="DOI">10.5194/amt-10-1299-2017</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx61"><label>Stanley et al.(2018)</label><mixed-citation>Stanley, K. M., Grant, A., O'Doherty, S., Young, D., Manning, A. J., Stavert, A. R., Spain, T. G., Salameh, P. K., Harth, C. M., Simmonds, P. G., Sturges, W. T., Oram, D. E., and Derwent, R. G.: Greenhouse gas measurements from a UK network of tall towers: technical description and first results, Atmos. Meas. Tech., 11, 1437–1458, <ext-link xlink:href="https://doi.org/10.5194/amt-11-1437-2018" ext-link-type="DOI">10.5194/amt-11-1437-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx62"><label>Stavert et al.(2019)</label><mixed-citation>Stavert, A. R., O'Doherty, S., Stanley, K., Young, D., Manning, A. J., Lunt, M. F., Rennick, C., and Arnold, T.: UK greenhouse gas measurements at two new tall towers for aiding emissions verification, Atmos. Meas. Tech., 12, 4495–4518, <ext-link xlink:href="https://doi.org/10.5194/amt-12-4495-2019" ext-link-type="DOI">10.5194/amt-12-4495-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx63"><label>Stull(1988)</label><mixed-citation>Stull, R. B.: An introduction to boundary layer meteorology, Kluwer Academic Publishers, <ext-link xlink:href="https://doi.org/10.1007/978-94-009-3027-8" ext-link-type="DOI">10.1007/978-94-009-3027-8</ext-link>, 1988.​​​​​​​</mixed-citation></ref>
      <ref id="bib1.bibx64"><label>Taguchi et al.(2002)</label><mixed-citation>Taguchi, S., Iida, T., and Moriizumi, J.: Evaluation of the atmospheric transport model NIRE-CTM-96 by using measured radon-222 concentrations, Tellus B, 54, 250–268, <ext-link xlink:href="https://doi.org/10.3402/tellusb.v54i3.16664" ext-link-type="DOI">10.3402/tellusb.v54i3.16664</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx65"><label>Taylor and Lucas(1967)</label><mixed-citation>Taylor, J. A. and Lucas, J.: Atmospheric radon monitor, Tech. Rep. ANL-7220, Argonne National Lab., Ill.,  <uri>https://www.osti.gov/biblio/4405995</uri> (last access: 20 December 2024), 1967.</mixed-citation></ref>
      <ref id="bib1.bibx66"><label>Thomas and Leclare(1970)</label><mixed-citation>Thomas, J. W. and Leclare, P. C.: A study of the two-filter method for radon-222, Health Phys., 18, 113–122, <uri>https://journals.lww.com/health-physics/Abstract/1970/02000/A_Study_of_the_Two_filter_Method_for_Radon_222.2.aspx</uri> (last access: 20 December 2024), 1970.​​​​​​​</mixed-citation></ref>
      <ref id="bib1.bibx67"><label>Tolk et al.(2008)</label><mixed-citation>Tolk, L. F., Meesters, A. G. C. A., Dolman, A. J., and Peters, W.: Modelling representation errors of atmospheric CO<sub>2</sub> mixing ratios at a regional scale, Atmos. Chem. Phys., 8, 6587–6596, <ext-link xlink:href="https://doi.org/10.5194/acp-8-6587-2008" ext-link-type="DOI">10.5194/acp-8-6587-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx68"><label>van der Laan et al.(2009)</label><mixed-citation>van der Laan, S., Neubert, R. E. M., and Meijer, H. A. J.: Methane and nitrous oxide emissions in The Netherlands: ambient measurements support the national inventories, Atmos. Chem. Phys., 9, 9369–9379, <ext-link xlink:href="https://doi.org/10.5194/acp-9-9369-2009" ext-link-type="DOI">10.5194/acp-9-9369-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx69"><label>van der Laan et al.(2014)</label><mixed-citation>van der Laan, S., van der Laan-Luijkx, I. T., Zimmermann, L., Conen, F., and Leuenberger, M.: Net CO<sub>2</sub> surface emissions at Bern, Switzerland inferred from ambient observations of CO<sub>2</sub>, <inline-formula><mml:math id="M275" display="inline"><mml:mi mathvariant="italic">δ</mml:mi></mml:math></inline-formula>(O<sub>2</sub>/N<sub>2</sub>), and <sup>222</sup>Rn using a customized radon tracer inversion, J. Geophys. Res.-Atmos., 119, 1580–1591, <ext-link xlink:href="https://doi.org/10.1002/2013JD020307" ext-link-type="DOI">10.1002/2013JD020307</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx70"><label>Vogel et al.(2012)</label><mixed-citation>Vogel, F., Ishizawa, M., Chan, E., Chan, D., Hammer, S., Levin, I., and Worthy, D.: Regional non-CO<sub>2</sub> greenhouse gas fluxes inferred from atmospheric measurements in Ontario, Canada, J. Integr. Environ. Sci., 9, 41–55, <ext-link xlink:href="https://doi.org/10.1080/1943815X.2012.691884" ext-link-type="DOI">10.1080/1943815X.2012.691884</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx71"><label>Wada et al.(2013)</label><mixed-citation>Wada, A., Matsueda, H., Murayama, S., Taguchi, S., Hirao, S., Yamazawa, H., Moriizumi, J., Tsuboi, K., Niwa, Y., and Sawa, Y.: Quantification of emission estimates of CO<sub>2</sub>, CH<sub>4</sub> and CO for East Asia derived from atmospheric radon-222 measurements over the western North Pacific, Tellus B, 65, 18037, <ext-link xlink:href="https://doi.org/10.3402/tellusb.v65i0.18037" ext-link-type="DOI">10.3402/tellusb.v65i0.18037</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx72"><label>Whittlestone and Zahorowski(1998)</label><mixed-citation>Whittlestone, S. and Zahorowski, W.: Baseline radon detectors for shipboard use: Development and deployment in the First Aerosol Characterization Experiment (ACE 1), J. Geophys. Res.-Atmos., 103, 16743–16751, <ext-link xlink:href="https://doi.org/10.1029/98JD00687" ext-link-type="DOI">10.1029/98JD00687</ext-link>, 1998.</mixed-citation></ref>
      <ref id="bib1.bibx73"><label>Wigand and Wenk(1928)</label><mixed-citation>Wigand, A. and Wenk, F.: Der gehalt der luft an radium-emanation, nach messungen bei flugzeugaufstiegen, Ann. Phys., 391, 657–686, <ext-link xlink:href="https://doi.org/10.1002/andp.19283911302" ext-link-type="DOI">10.1002/andp.19283911302</ext-link>, 1928.</mixed-citation></ref>
      <ref id="bib1.bibx74"><label>Williams et al.(2013)</label><mixed-citation>Williams, A. G., Chambers, S., and Griffiths, A.: Bulk mixing and decoupling of the nocturnal stable boundary layer characterized using a ubiquitous natural tracer, Bound.-Lay. Meteorol., 149, 381–402, <ext-link xlink:href="https://doi.org/10.1007/s10546-013-9849-3" ext-link-type="DOI">10.1007/s10546-013-9849-3</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx75"><label>Williams et al.(2016)</label><mixed-citation>Williams, A. G., Chambers, S. D., Conen, F., Reimann, S., Hill, M., Griffiths, A. D., and Crawford, J.: Radon as a tracer of atmospheric influences on traffic-related air pollution in a small inland city, Tellus B, 68, 30967, <ext-link xlink:href="https://doi.org/10.3402/tellusb.v68.30967" ext-link-type="DOI">10.3402/tellusb.v68.30967</ext-link>, 2016.​​​​​​​</mixed-citation></ref>
      <ref id="bib1.bibx76"><label>Wright(2017)</label><mixed-citation>Wright, A. G.: PMT background, in: The Photomultiplier Handbook, edited by: Wright, A. G., Oxford University Press, ISBN 978-0-19-956509-2, <ext-link xlink:href="https://doi.org/10.1093/oso/9780199565092.003.0006" ext-link-type="DOI">10.1093/oso/9780199565092.003.0006</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx77"><label>Wright and Smith(1915)</label><mixed-citation>Wright, J. R. and Smith, O. F.: The variation with meteorological conditions of the amount of radium emanation in the atmosphere, in the soil gas, and in the air exhaled from the surface of the ground, at Manila, Phys. Rev., 5, 459–482, <ext-link xlink:href="https://doi.org/10.1103/PhysRev.5.459" ext-link-type="DOI">10.1103/PhysRev.5.459</ext-link>, 1915.</mixed-citation></ref>
      <ref id="bib1.bibx78"><label>Xia et al.(2010)</label><mixed-citation>Xia, Y., Sartorius, H., Schlosser, C., Stöhlker, U., Conen, F., and Zahorowski, W.: Comparison of one- and two-filter detectors for atmospheric <sup>222</sup>Rn measurements under various meteorological conditions, Atmos. Meas. Tech., 3, 723–731, <ext-link xlink:href="https://doi.org/10.5194/amt-3-723-2010" ext-link-type="DOI">10.5194/amt-3-723-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx79"><label>Yver Kwok et al.(2015)</label><mixed-citation>Yver Kwok, C., Laurent, O., Guemri, A., Philippon, C., Wastine, B., Rella, C. W., Vuillemin, C., Truong, F., Delmotte, M., Kazan, V., Darding, M., Lebègue, B., Kaiser, C., Xueref-Rémy, I., and Ramonet, M.: Comprehensive laboratory and field testing of cavity ring-down spectroscopy analyzers measuring H<sub>2</sub>O, CO<sub>2</sub>, CH<sub>4</sub> and CO, Atmos. Meas. Tech., 8, 3867–3892, <ext-link xlink:href="https://doi.org/10.5194/amt-8-3867-2015" ext-link-type="DOI">10.5194/amt-8-3867-2015</ext-link>, 2015. </mixed-citation></ref>
      <ref id="bib1.bibx80"><label>Yver-Kwok et al.(2021)</label><mixed-citation>Yver-Kwok, C., Philippon, C., Bergamaschi, P., Biermann, T., Calzolari, F., Chen, H., Conil, S., Cristofanelli, P., Delmotte, M., Hatakka, J., Heliasz, M., Hermansen, O., Komínková, K., Kubistin, D., Kumps, N., Laurent, O., Laurila, T., Lehner, I., Levula, J., Lindauer, M., Lopez, M., Mammarella, I., Manca, G., Marklund, P., Metzger, J.-M., Mölder, M., Platt, S. M., Ramonet, M., Rivier, L., Scheeren, B., Sha, M. K., Smith, P., Steinbacher, M., Vítková, G., and Wyss, S.: Evaluation and optimization of ICOS atmosphere station data as part of the labeling process, Atmos. Meas. Tech., 14, 89–116, <ext-link xlink:href="https://doi.org/10.5194/amt-14-89-2021" ext-link-type="DOI">10.5194/amt-14-89-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx81"><label>Zahorowski et al.(2004)</label><mixed-citation>Zahorowski, W., Chambers, S. D., and Henderson-Sellers, A.: Determination of mid-latitude radon-222 flux from the Southern Ocean using atmospheric radon-222 concentration measurements at an island ground station, International Atomic Energy Agency, <uri>https://inis.iaea.org/collection/NCLCollectionStore/_Public/36/003/36003223.pdf?r=1#page=5&amp;zoom=auto,-15,800</uri> (last access: 20 December 2024), 2004.</mixed-citation></ref>
      <ref id="bib1.bibx82"><label>Zhang et al.(2021)</label><mixed-citation>Zhang, B., Liu, H., Crawford, J. H., Chen, G., Fairlie, T. D., Chambers, S., Kang, C.-H., Williams, A. G., Zhang, K., Considine, D. B., Sulprizio, M. P., and Yantosca, R. M.: Simulation of radon-222 with the GEOS-Chem global model: emissions, seasonality, and convective transport, Atmos. Chem. Phys., 21, 1861–1887, <ext-link xlink:href="https://doi.org/10.5194/acp-21-1861-2021" ext-link-type="DOI">10.5194/acp-21-1861-2021</ext-link>, 2021.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Direct high-precision radon quantification for interpreting high-frequency greenhouse gas measurements</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Adcock et al.(2023)</label><mixed-citation>
      
Adcock, K. E., Pickers, P. A., Manning, A. C., Forster, G. L., Fleming, L. S., Barningham, T., Wilson, P. A., Kozlova, E. A., Hewitt, M., Etchells, A. J., and Macdonald, A. J.: 12 years of continuous atmospheric O<sub>2</sub>, CO<sub>2</sub> and APO data from Weybourne Atmospheric Observatory in the United Kingdom, Earth Syst. Sci. Data, 15, 5183–5206, <a href="https://doi.org/10.5194/essd-15-5183-2023" target="_blank">https://doi.org/10.5194/essd-15-5183-2023</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Alduchov and Eskridge(1996)</label><mixed-citation>
      
Alduchov, O. A. and Eskridge, R. E.: Improved Magnus form approximation of saturation vapor pressure, J. Appl. Meteorol., 35, 601–609, 1996.​​​​​​​

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Arnold et al.(2018)</label><mixed-citation>
      
Arnold, T., Manning, A. J., Kim, J., Li, S., Webster, H., Thomson, D., Mühle, J., Weiss, R. F., Park, S., and O'Doherty, S.: Inverse modelling of CF<sub>4</sub> and NF<sub>3</sub> emissions in East Asia, Atmos. Chem. Phys., 18, 13305–13320, <a href="https://doi.org/10.5194/acp-18-13305-2018" target="_blank">https://doi.org/10.5194/acp-18-13305-2018</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Baker et al.(2006)</label><mixed-citation>
      
Baker, D. F., Law, R. M., Gurney, K. R., Rayner, P., Peylin, P., Denning, A. S., Bousquet, P., Bruhwiler, L., Chen, Y.-H., Ciais, P., Fung, I. Y., Heimann, M., John, J., Maki, T., Maksyutov, S., Masarie, K., Prather, M., Pak, B., Taguchi, S., and Zhu, Z.: TransCom 3 inversion intercomparison: Impact of transport model errors on the interannual variability of regional
CO<sub>2</sub> fluxes, 1988–2003, Global Biogeochem. Cy., 20, GB1002,
<a href="https://doi.org/10.1029/2004GB002439" target="_blank">https://doi.org/10.1029/2004GB002439</a>, 2006.​​​​​​​

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Bergamaschi et al.(2015)</label><mixed-citation>
      
Bergamaschi, P., Corazza, M., Karstens, U., Athanassiadou, M., Thompson, R. L., Pison, I., Manning, A. J., Bousquet, P., Segers, A., Vermeulen, A. T., Janssens-Maenhout, G., Schmidt, M., Ramonet, M., Meinhardt, F., Aalto, T., Haszpra, L., Moncrieff, J., Popa, M. E., Lowry, D., Steinbacher, M., Jordan, A., O'Doherty, S., Piacentino, S., and Dlugokencky, E.: Top-down estimates of European CH<sub>4</sub> and N<sub>2</sub>O emissions based on four different inverse models, Atmos. Chem. Phys., 15, 715–736, <a href="https://doi.org/10.5194/acp-15-715-2015" target="_blank">https://doi.org/10.5194/acp-15-715-2015</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Bergamaschi et al.(2018)</label><mixed-citation>
      
Bergamaschi, P., Karstens, U., Manning, A. J., Saunois, M., Tsuruta, A., Berchet, A., Vermeulen, A. T., Arnold, T., Janssens-Maenhout, G., Hammer, S., Levin, I., Schmidt, M., Ramonet, M., Lopez, M., Lavric, J., Aalto, T., Chen, H., Feist, D. G., Gerbig, C., Haszpra, L., Hermansen, O., Manca, G., Moncrieff, J., Meinhardt, F., Necki, J., Galkowski, M., O'Doherty, S., Paramonova, N., Scheeren, H. A., Steinbacher, M., and Dlugokencky, E.: Inverse modelling of European CH<sub>4</sub> emissions during 2006–2012 using different inverse models and reassessed atmospheric observations, Atmos. Chem. Phys., 18, 901–920, <a href="https://doi.org/10.5194/acp-18-901-2018" target="_blank">https://doi.org/10.5194/acp-18-901-2018</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Biraud et al.(2000)</label><mixed-citation>
      
Biraud, S., Ciais, P., Ramonet, M., Simmonds, P., Kazan, V., Monfray, P., O'Doherty, S., Spain, T. G., and Jennings, S. G.: European greenhouse gas emissions estimated from continuous atmospheric measurements and radon 222 at Mace Head, Ireland, J. Geophys. Res.-Atmos., 105, 1351–1366, <a href="https://doi.org/10.1029/1999JD900821" target="_blank">https://doi.org/10.1029/1999JD900821</a>, 2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Brown et al.(2023)</label><mixed-citation>
      
Brown, P., Cardenas, L., Del Vento, S., Karagianni, E., MacCarthy, J., Mullen, P., Passant, N., Richmond, B., Thistlethwaite, G., Thomson, A., Wakeling, D., and Willis, D.: UK greenhouse gas inventory, 1990 to 2021: annual report for submission under the Framework Convention on Climate Change, Ricardo Energy &amp; Environment, ISBN 9780993397592, 601 pp., <a href="https://naei.energysecurity.gov.uk/reports/uk-greenhouse-gas-inventory-1990-2022-annual-report-submission-under-framework-convention" target="_blank">https://naei.energysecurity.gov.uk/reports/uk-greenhouse-gas-inventory-1990-2022-annual-report-submission-under-framework-convention</a> (last access: 12 January 2025), 2024.​​​​​​​

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Chambers et al.(2011)</label><mixed-citation>
      
Chambers, S., Williams, A. G., Zahorowski, W., Griffiths, A., and Crawford, J.: Separating remote fetch and local mixing influences on vertical radon measurements in the lower atmosphere, Tellus B, 63, 843–859, <a href="https://doi.org/10.1111/j.1600-0889.2011.00565.x" target="_blank">https://doi.org/10.1111/j.1600-0889.2011.00565.x</a>, 2011.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Chambers et al.(2015)</label><mixed-citation>
      
Chambers, S. D., Williams, A. G., Crawford, J., and Griffiths, A. D.: On the use of radon for quantifying the effects of atmospheric stability on urban emissions, Atmos. Chem. Phys., 15, 1175–1190, <a href="https://doi.org/10.5194/acp-15-1175-2015" target="_blank">https://doi.org/10.5194/acp-15-1175-2015</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Chambers et al.(2016)</label><mixed-citation>
      
Chambers, S. D., Williams, A. G., Conen, F., Griffiths, A. D., Reimann, S., Steinbacher, M., Krummel, P. B., Steele, L. P., Schoot, M. V. V. D., Galbally, I. E., Molloy, S. B., and Barnes, J. E.: Towards a Universal “Baseline” Characterisation of Air Masses for High- and Low-Altitude Observing Stations Using Radon-222, Aerosol Air
Qual. Res., 16, 885–899, <a href="https://doi.org/10.4209/aaqr.2015.06.0391" target="_blank">https://doi.org/10.4209/aaqr.2015.06.0391</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Chambers et al.(2019a)</label><mixed-citation>
      
Chambers, S. D., Guérette, E.-A., Monk, K., Griffiths, A. D., Zhang, Y., Duc, H., Cope, M., Emmerson, K. M., Chang, L. T., Silver, J. D., Utembe, S., Crawford, J., Williams, A. G., and Keywood, M.: Skill-Testing Chemical Transport Models across Contrasting Atmospheric Mixing States Using Radon-222, Atmosphere, 10, 25, <a href="https://doi.org/10.3390/atmos10010025" target="_blank">https://doi.org/10.3390/atmos10010025</a>, 2019a.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Chambers et al.(2019b)</label><mixed-citation>
      
Chambers, S. D., Podstawczyńska, A., Pawlak, W., Fortuniak, K., Williams, A. G., and Griffiths, A. D.: Characterizing the State of the Urban Surface Layer Using Radon-222, J. Geophys. Res.-Atmos., 124, 770–788, <a href="https://doi.org/10.1029/2018JD029507" target="_blank">https://doi.org/10.1029/2018JD029507</a>, 2019b.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Chambers et al.(2022)</label><mixed-citation>
      
Chambers, S. D., Griffiths, A. D., Williams, A. G., Sisoutham, O., Morosh, V., Röttger, S., Mertes, F., and Röttger, A.: Portable two-filter dual-flow-loop <sup>222</sup>Rn detector: stand-alone monitor and calibration transfer device, Adv. Geosci., 57, 63–80, <a href="https://doi.org/10.5194/adgeo-57-63-2022" target="_blank">https://doi.org/10.5194/adgeo-57-63-2022</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Chevillard et al.(2002)</label><mixed-citation>
      
Chevillard, A., Ciais, P., Karstens, U., Heimann, M., Schmidt, M., Levin, I., Jacob, D., Podzun, R., Kazan, V., Sartorius, H., and Weingartner, E.: Transport of <sup>222</sup>Rn using the regional model REMO: a detailed comparison with measurements over Europe, Tellus B, 54, 850–871, <a href="https://doi.org/10.3402/tellusb.v54i5.16735" target="_blank">https://doi.org/10.3402/tellusb.v54i5.16735</a>, 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Ciais et al.(2014)</label><mixed-citation>
      
Ciais, P., Dolman, A. J., Bombelli, A., Duren, R., Peregon, A., Rayner, P. J., Miller, C., Gobron, N., Kinderman, G., Marland, G., Gruber, N., Chevallier, F., Andres, R. J., Balsamo, G., Bopp, L., Bréon, F.-M., Broquet, G., Dargaville, R., Battin, T. J., Borges, A., Bovensmann, H., Buchwitz, M., Butler, J., Canadell, J. G., Cook, R. B., DeFries, R., Engelen, R., Gurney, K. R., Heinze, C., Heimann, M., Held, A., Henry, M., Law, B., Luyssaert, S., Miller, J., Moriyama, T., Moulin, C., Myneni, R. B., Nussli, C., Obersteiner, M., Ojima, D., Pan, Y., Paris, J.-D., Piao, S. L., Poulter, B., Plummer, S., Quegan, S., Raymond, P., Reichstein, M., Rivier, L., Sabine, C., Schimel, D., Tarasova, O., Valentini, R., Wang, R., van der Werf, G., Wickland, D., Williams, M., and Zehner, C.: Current systematic carbon-cycle observations and the need for implementing a policy-relevant carbon observing system, Biogeosciences, 11, 3547–3602, <a href="https://doi.org/10.5194/bg-11-3547-2014" target="_blank">https://doi.org/10.5194/bg-11-3547-2014</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Crotwell et al.(2017)</label><mixed-citation>
      
Crotwell, A., Steinbacher, M., World Meteorological Organization (WMO)​​​​​​​, and 19th WMO/IAEA Meeting on Carbon Dioxide: 19th WMO/IAEA Meeting on Carbon Dioxide, Other Greenhouse Gases and Related Measurement Techniques (GGMT-2017), Dübendorf, Switzerland, 27–31 August 2017, Tech. rep., WMO, <a href="https://library.wmo.int/records/item/37000-19th-wmo-iaea-meeting-on-carbon-dioxide-other-greenhouse-gases-and-related-measurement-techniques-ggmt-2017#.Xmdl6Oko9rk" target="_blank">https://library.wmo.int/records/item/37000-19th-wmo-iaea-meeting-on-carbon-dioxide-other-greenhouse-gases-and-related-measurement-techniques-ggmt-2017#.Xmdl6Oko9rk</a> (last access: 20 December 2024), 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Dentener et al.(1999)</label><mixed-citation>
      
Dentener, F., Feichter, J., and Jeuken, A.: Simulation of the transport of <sup>222</sup>Rn using on-line and off-line global models at different horizontal resolutions: a detailed comparison with measurements, Tellus B, 51, 573–602, <a href="https://doi.org/10.3402/tellusb.v51i3.16440" target="_blank">https://doi.org/10.3402/tellusb.v51i3.16440</a>, 1999.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Eve(1908)</label><mixed-citation>
      
Eve, A.: LI. On the amount of radium emanation in the atmosphere near the earth's surface, London Edinburgh Philos. Mag. &amp; J. Sci., 16, 622–632, <a href="https://doi.org/10.1080/14786441008636540" target="_blank">https://doi.org/10.1080/14786441008636540</a>, 1908.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Fleming et al.(2012)</label><mixed-citation>
      
Fleming, Z. L., Monks, P. S., and Manning, A. J.: Review: Untangling the influence of air-mass history in interpreting observed atmospheric composition, Atmos. Res., 104–105, 1–39, <a href="https://doi.org/10.1016/j.atmosres.2011.09.009" target="_blank">https://doi.org/10.1016/j.atmosres.2011.09.009</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Forster(2024)</label><mixed-citation>
      
Forster, G.: Weybourne Atmospheric Observatory, NERC EDS Centre for Environmental Data Analysis [data set], <a href="https://data.ceda.ac.uk/badc/ncas-wao/data/ncas-ftir-1/20170801_longterm/v3.0" target="_blank"/> (last access: 13 January 2025), 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Forster et al.(2012)</label><mixed-citation>
      
Forster, G. L., Sturges, W. T., Fleming, Z. L., Bandy, B. J., and Emeis, S.: A year of H<sub>2</sub> measurements at Weybourne Atmospheric Observatory, UK, Tellus B, 64, 17771, <a href="https://doi.org/10.3402/tellusb.v64i0.17771" target="_blank">https://doi.org/10.3402/tellusb.v64i0.17771</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Forster et al.(2024)</label><mixed-citation>
      
Forster, G., Chung, E., and Kikaj, D.: Weybourne Atmospheric Observatory,  NERC EDS Centre for Environmental Data Analysis [data set], <a href="https://data.ceda.ac.uk/badc/ncas-wao/data/uea-radon-1/20180321_longterm/v1.0" target="_blank"/> (last access: 13 January 2025), 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Galmarini(2006)</label><mixed-citation>
      
Galmarini, S.: One year of <sup>222</sup>Rn concentration in the atmospheric surface layer, Atmos. Chem. Phys., 6, 2865–2886, <a href="https://doi.org/10.5194/acp-6-2865-2006" target="_blank">https://doi.org/10.5194/acp-6-2865-2006</a>, 2006.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Ganesan et al.(2015)</label><mixed-citation>
      
Ganesan, A. L., Manning, A. J., Grant, A., Young, D., Oram, D. E., Sturges, W. T., Moncrieff, J. B., and O'Doherty, S.: Quantifying methane and nitrous oxide emissions from the UK and Ireland using a national-scale monitoring network, Atmos. Chem. Phys., 15, 6393–6406, <a href="https://doi.org/10.5194/acp-15-6393-2015" target="_blank">https://doi.org/10.5194/acp-15-6393-2015</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Geels et al.(2007)</label><mixed-citation>
      
Geels, C., Gloor, M., Ciais, P., Bousquet, P., Peylin, P., Vermeulen, A. T., Dargaville, R., Aalto, T., Brandt, J., Christensen, J. H., Frohn, L. M., Haszpra, L., Karstens, U., Rödenbeck, C., Ramonet, M., Carboni, G., and Santaguida, R.: Comparing atmospheric transport models for future regional inversions over Europe – Part 1: mapping the atmospheric CO<sub>2</sub> signals, Atmos. Chem. Phys., 7, 3461–3479, <a href="https://doi.org/10.5194/acp-7-3461-2007" target="_blank">https://doi.org/10.5194/acp-7-3461-2007</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Gerbig et al.(2008)</label><mixed-citation>
      
Gerbig, C., Körner, S., and Lin, J. C.: Vertical mixing in atmospheric tracer transport models: error characterization and propagation, Atmos. Chem. Phys., 8, 591–602, <a href="https://doi.org/10.5194/acp-8-591-2008" target="_blank">https://doi.org/10.5194/acp-8-591-2008</a>, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Griffiths(2024a)</label><mixed-citation>
      
Griffiths, A.: anstoradonlab/radcalsim: Radon detector calibration simulator, Zenodo [code], <a href="https://doi.org/10.5281/zenodo.14504261" target="_blank">https://doi.org/10.5281/zenodo.14504261</a>, 2024a.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Griffiths(2024b)</label><mixed-citation>
      
Griffiths, A.: anstoradonlab/radon-monitor: RDM 10.17.2, Zenodo [code], <a href="https://doi.org/10.5281/zenodo.14504311" target="_blank">https://doi.org/10.5281/zenodo.14504311</a>, 2024b.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Griffiths(2024c)</label><mixed-citation>
      
Griffiths, A.: anstoradonlab/rdfix: v0.4.1, Zenodo [code], <a href="https://doi.org/10.5281/zenodo.14503937" target="_blank">https://doi.org/10.5281/zenodo.14503937</a>, 2024c.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Griffiths et al.(2016)</label><mixed-citation>
      
Griffiths, A. D., Chambers, S. D., Williams, A. G., and Werczynski, S.: Increasing the accuracy and temporal resolution of two-filter radon–222 measurements by correcting for the instrument response, Atmos. Meas. Tech., 9, 2689–2707, <a href="https://doi.org/10.5194/amt-9-2689-2016" target="_blank">https://doi.org/10.5194/amt-9-2689-2016</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>Grossi et al.(2012)</label><mixed-citation>
      
Grossi, C., Arnold, D., Adame, J. A., López-Coto, I., Bolívar, J. P., de la Morena, B. A., and Vargas, A.: Atmospheric <sup>222</sup>Rn concentration and source term at El Arenosillo 100&thinsp;m meteorological tower in southwest Spain, Radiat. Meas., 47, 149–162, <a href="https://doi.org/10.1016/j.radmeas.2011.11.006" target="_blank">https://doi.org/10.1016/j.radmeas.2011.11.006</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Grossi et al.(2018)</label><mixed-citation>
      
Grossi, C., Vogel, F. R., Curcoll, R., Àgueda, A., Vargas, A., Rodó, X., and Morguí, J.-A.: Study of the daily and seasonal atmospheric CH<sub>4</sub> mixing ratio variability in a rural Spanish region using <sup>222</sup>Rn tracer, Atmos. Chem. Phys., 18, 5847–5860, <a href="https://doi.org/10.5194/acp-18-5847-2018" target="_blank">https://doi.org/10.5194/acp-18-5847-2018</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Grossi et al.(2020)</label><mixed-citation>
      
Grossi, C., Chambers, S. D., Llido, O., Vogel, F. R., Kazan, V., Capuana, A., Werczynski, S., Curcoll, R., Delmotte, M., Vargas, A., Morguí, J.-A., Levin, I., and Ramonet, M.: Intercomparison study of atmospheric <sup>222</sup>Rn and <sup>222</sup>Rn progeny monitors, Atmos. Meas. Tech., 13, 2241–2255, <a href="https://doi.org/10.5194/amt-13-2241-2020" target="_blank">https://doi.org/10.5194/amt-13-2241-2020</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Gurney et al.(2016)</label><mixed-citation>
      
Gurney, K. R., Huang, J., and Coltin, K.: Bias present in US federal agency power plant CO<sub>2</sub> emissions data and implications for the US clean power plan, Environ. Res. Lett., 11, 064005,
<a href="https://doi.org/10.1088/1748-9326/11/6/064005" target="_blank">https://doi.org/10.1088/1748-9326/11/6/064005</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>Hammer et al.(2013)</label><mixed-citation>
      
Hammer, S., Griffith, D. W. T., Konrad, G., Vardag, S., Caldow, C., and Levin, I.: Assessment of a multi-species in situ FTIR for precise atmospheric greenhouse gas observations, Atmos. Meas. Tech., 6, 1153–1170, <a href="https://doi.org/10.5194/amt-6-1153-2013" target="_blank">https://doi.org/10.5194/amt-6-1153-2013</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>Hirao et al.(2008)</label><mixed-citation>
      
Hirao, S., Yamazawa, H., Moriizumi, J., Yoshioka, K., and Iida, T.: Development and verification of long-range atmospheric Radon-222 transport model, J. Nucl. Sci. Technol., 45, 166–172,
<a href="https://doi.org/10.1080/00223131.2008.10876001" target="_blank">https://doi.org/10.1080/00223131.2008.10876001</a>, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>Hirsch(2007)</label><mixed-citation>
      
Hirsch, A. I.: On using radon-222 and CO<sub>2</sub> to calculate regional-scale CO<sub>2</sub> fluxes, Atmos. Chem. Phys., 7, 3737–3747, <a href="https://doi.org/10.5194/acp-7-3737-2007" target="_blank">https://doi.org/10.5194/acp-7-3737-2007</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>Israël et al.(1966)</label><mixed-citation>
      
Israël, H., Horbert, M., and Israël, G. W.: Results of continuous measurements of radon and its decay products in the lower atmosphere, Tellus,
18, 639–642, <a href="https://doi.org/10.3402/tellusa.v18i2-3.9204" target="_blank">https://doi.org/10.3402/tellusa.v18i2-3.9204</a>, 1966.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>Jacob et al.(1997)</label><mixed-citation>
      
Jacob, D. J., Prather, M. J., Rasch, P. J., Shia, R.-L., Balkanski, Y. J., Beagley, S. R., Bergmann, D. J., Blackshear, W. T., Brown, M., Chiba, M., Chipperfield, M. P., de Grandpré, J., Dignon, J. E., Feichter, J., Genthon, C., Grose, W. L., Kasibhatla, P. S., Köhler, I., Kritz, M. A., Law, K., Penner, J. E., Ramonet, M., Reeves, C. E., Rotman, D. A., Stockwell, D. Z., Van Velthoven, P. F. J., Verver, G., Wild, O., Yang, H., and Zimmermann, P.: Evaluation and intercomparison of global atmospheric transport models using <sup>222</sup>Rn and other short-lived tracers, J. Geophys. Res.-Atmos., 102, 5953–5970, <a href="https://doi.org/10.1029/96JD02955" target="_blank">https://doi.org/10.1029/96JD02955</a>, 1997.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>Kikaj et al.(2019)</label><mixed-citation>
      
Kikaj, D., Vaupotič, J., and Chambers, S. D.: Identifying persistent temperature inversion events in a subalpine basin using radon-222, Atmos. Meas. Tech., 12, 4455–4477, <a href="https://doi.org/10.5194/amt-12-4455-2019" target="_blank">https://doi.org/10.5194/amt-12-4455-2019</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>Kikaj et al.(2023)</label><mixed-citation>
      
Kikaj, D., Chambers, S. D., Crawford, J., Kobal, M., Gregorič, A., and Vaupotič, J.: Investigating the vertical and spatial extent of radon-based classification of the atmospheric mixing state and impacts on seasonal urban air quality, Sci. Total Environ., 872, 162126, <a href="https://doi.org/10.1016/j.scitotenv.2023.162126" target="_blank">https://doi.org/10.1016/j.scitotenv.2023.162126</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>Lambert et al.(1970)</label><mixed-citation>
      
Lambert, G., Polian, G., Taupin, D., and Lambert, R.: Existence of periodicity in radon concentrations and in the large-scale circulation at lower altitudes' between 40° and 70° South, J. Geophys. Res., 75, 2341–2345, <a href="https://doi.org/10.1029/JC075i012p02341" target="_blank">https://doi.org/10.1029/JC075i012p02341</a>, 1970.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>Levin(1987)</label><mixed-citation>
      
Levin, I.: Atmospheric CO<sub>2</sub> in continental Europe – an alternative approach to clean air CO<sub>2</sub> data, Tellus B, 39B, 21–28, <a href="https://doi.org/10.1111/j.1600-0889.1987.tb00267.x" target="_blank">https://doi.org/10.1111/j.1600-0889.1987.tb00267.x</a>, 1987.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>Levin et al.(2002)</label><mixed-citation>
      
Levin, I., Born, M., Cuntz, M., Langendörfer, U., Mantsch, S., Naegler, T., Schmidt, M., Varlagin, A., Verclas, S., and Wagenbach, D.: Observations of atmospheric variability and soil exhalation rate of radon-222 at a Russian forest site. Technical approach and deployment for boundary layer studies,
Tellus B, 54, 462–475, <a href="https://doi.org/10.1034/j.1600-0889.2002.01346.x" target="_blank">https://doi.org/10.1034/j.1600-0889.2002.01346.x</a>, 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>Levin et al.(2021)</label><mixed-citation>
      
Levin, I., Karstens, U., Hammer, S., DellaColetta, J., Maier, F., and Gachkivskyi, M.: Limitations of the radon tracer method (RTM) to estimate regional greenhouse gas (GHG) emissions – a case study for methane in Heidelberg, Atmos. Chem. Phys., 21, 17907–17926, <a href="https://doi.org/10.5194/acp-21-17907-2021" target="_blank">https://doi.org/10.5194/acp-21-17907-2021</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>Liu et al.(2011)</label><mixed-citation>
      
Liu, J., Fung, I., Kalnay, E., and Kang, J.-S.: CO<sub>2</sub> transport uncertainties from the uncertainties in meteorological fields, Geophys. Res. Lett., 38, L12808, <a href="https://doi.org/10.1029/2011GL047213" target="_blank">https://doi.org/10.1029/2011GL047213</a>, 2011.​​​​​​​

    </mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>Lunt et al.(2021)</label><mixed-citation>
      
Lunt, M. F., Manning, A. J., Allen, G., Arnold, T., Bauguitte, S. J.-B., Boesch, H., Ganesan, A. L., Grant, A., Helfter, C., Nemitz, E., O'Doherty, S. J., Palmer, P. I., Pitt, J. R., Rennick, C., Say, D., Stanley, K. M., Stavert, A. R., Young, D., and Rigby, M.: Atmospheric observations consistent with reported decline in the UK's methane emissions (2013–2020), Atmos. Chem. Phys., 21, 16257–16276, <a href="https://doi.org/10.5194/acp-21-16257-2021" target="_blank">https://doi.org/10.5194/acp-21-16257-2021</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>Mahowald et al.(1995)</label><mixed-citation>
      
Mahowald, N. M., Rasch, P. J., and Prinn, R. G.: Cumulus parameterizations in chemical transport models, J. Geophys. Res.-Atmos., 100, 26173–26189,
<a href="https://doi.org/10.1029/95JD02606" target="_blank">https://doi.org/10.1029/95JD02606</a>, 1995.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>Manning et al.(2011)</label><mixed-citation>
      
Manning, A. J., O'Doherty, S., Jones, A. R., Simmonds, P. G., and Derwent, R. G.: Estimating UK methane and nitrous oxide emissions from 1990 to 2007 using an inversion modeling approach, J. Geophys. Res.-Atmos., 116, D02305,
<a href="https://doi.org/10.1029/2010JD014763" target="_blank">https://doi.org/10.1029/2010JD014763</a>, 2011.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>Manning et al.(2021)</label><mixed-citation>
      
Manning, A. J., Redington, A. L., Say, D., O'Doherty, S., Young, D., Simmonds, P. G., Vollmer, M. K., Mühle, J., Arduini, J., Spain, G., Wisher, A., Maione, M., Schuck, T. J., Stanley, K., Reimann, S., Engel, A., Krummel, P. B., Fraser, P. J., Harth, C. M., Salameh, P. K., Weiss, R. F., Gluckman, R., Brown, P. N., Watterson, J. D., and Arnold, T.: Evidence of a recent decline in UK emissions of hydrofluorocarbons determined by the InTEM inverse model and atmospheric measurements, Atmos. Chem. Phys., 21, 12739–12755, <a href="https://doi.org/10.5194/acp-21-12739-2021" target="_blank">https://doi.org/10.5194/acp-21-12739-2021</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>Munassar et al.(2023)</label><mixed-citation>
      
Munassar, S., Monteil, G., Scholze, M., Karstens, U., Rödenbeck, C., Koch, F.-T., Totsche, K. U., and Gerbig, C.: Why do inverse models disagree? A case study with two European CO<sub>2</sub> inversions, Atmos. Chem. Phys., 23, 2813–2828, <a href="https://doi.org/10.5194/acp-23-2813-2023" target="_blank">https://doi.org/10.5194/acp-23-2813-2023</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>Nisbet and Weiss(2010)</label><mixed-citation>
      
Nisbet, E. and Weiss, R.: Top-Down Versus Bottom-Up, Science, 328,
1241–1243, <a href="https://doi.org/10.1126/science.1189936" target="_blank">https://doi.org/10.1126/science.1189936</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>O'Doherty et al.(2024)</label><mixed-citation>
      
O'Doherty, S., Arnold, T., Chung, E., Ganesan, A., Garrard, N., Grant, A., Kikaj, D., Pitt, J., Rennick, C., Safi, E., Say, D., Spain, G., Stanley, K., Stavert, A., Wenger, A., Wisher, A., and Young, D.: Atmospheric trace gas observations from the UK Deriving Emissions linked to Climate Change (DECC) Network and associated data – Version 24.09, NERC EDS Centre for Environmental Data Analysis [data set], <a href="https://doi.org/10.5285/bd7164851bcc491b912f9d650fcf7981" target="_blank">https://doi.org/10.5285/bd7164851bcc491b912f9d650fcf7981</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>Penkett et al.(1999)</label><mixed-citation>
      
Penkett, S. A., Plane, J. M. C., Comes, F. J., Clemitshaw, K. C., and Coe, H.: The Weybourne Atmospheric Observatory, J. Atmos. Chem., 33, 107–110, <a href="https://doi.org/10.1023/A:1026428102821" target="_blank">https://doi.org/10.1023/A:1026428102821</a>, 1999.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>Pereira and Da Silva(1989)</label><mixed-citation>
      
Pereira, E. B. and Da Silva, H. E.: Atmospheric radon measurements by
electrostatic precipitation, Nucl. Instrum. Methods Phys. Res. A, 280,
503–505, <a href="https://doi.org/10.1016/0168-9002(89)90960-1" target="_blank">https://doi.org/10.1016/0168-9002(89)90960-1</a>, 1989.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>Perrino et al.(2001)</label><mixed-citation>
      
Perrino, C., Pietrodangelo, A., and Febo, A.: An atmospheric stability index based on radon progeny measurements for the evaluation of primary urban pollution, Atmos. Environ., 35, 5235–5244, <a href="https://doi.org/10.1016/S1352-2310(01)00349-1" target="_blank">https://doi.org/10.1016/S1352-2310(01)00349-1</a>, 2001.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>Polian et al.(1986)</label><mixed-citation>
      
Polian, G., Lambert, G., Ardouin, B., and Jegou, A.: Long-range transport of continental radon in subantarctic and antarctic areas, Tellus B, 38, 178–189, <a href="https://doi.org/10.3402/tellusb.v38i3-4.15126" target="_blank">https://doi.org/10.3402/tellusb.v38i3-4.15126</a>, 1986.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib59"><label>Röttger et al.(2023)</label><mixed-citation>
      
Röttger, S., Röttger, A., Mertes, F., Morosch, V., Ballé, T., and Chambers, S.: Evolution of traceable radon emanation sources from MBq to few Bq, Appl. Radiat. Isot., 196, 110726, <a href="https://doi.org/10.1016/j.apradiso.2023.110726" target="_blank">https://doi.org/10.1016/j.apradiso.2023.110726</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib60"><label>Schmithüsen et al.(2017)</label><mixed-citation>
      
Schmithüsen, D., Chambers, S., Fischer, B., Gilge, S., Hatakka, J., Kazan, V., Neubert, R., Paatero, J., Ramonet, M., Schlosser, C., Schmid, S., Vermeulen, A., and Levin, I.: A European-wide <sup>222</sup>radon and <sup>222</sup>radon progeny comparison study, Atmos. Meas. Tech., 10, 1299–1312, <a href="https://doi.org/10.5194/amt-10-1299-2017" target="_blank">https://doi.org/10.5194/amt-10-1299-2017</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib61"><label>Stanley et al.(2018)</label><mixed-citation>
      
Stanley, K. M., Grant, A., O'Doherty, S., Young, D., Manning, A. J., Stavert, A. R., Spain, T. G., Salameh, P. K., Harth, C. M., Simmonds, P. G., Sturges, W. T., Oram, D. E., and Derwent, R. G.: Greenhouse gas measurements from a UK network of tall towers: technical description and first results, Atmos. Meas. Tech., 11, 1437–1458, <a href="https://doi.org/10.5194/amt-11-1437-2018" target="_blank">https://doi.org/10.5194/amt-11-1437-2018</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib62"><label>Stavert et al.(2019)</label><mixed-citation>
      
Stavert, A. R., O'Doherty, S., Stanley, K., Young, D., Manning, A. J., Lunt, M. F., Rennick, C., and Arnold, T.: UK greenhouse gas measurements at two new tall towers for aiding emissions verification, Atmos. Meas. Tech., 12, 4495–4518, <a href="https://doi.org/10.5194/amt-12-4495-2019" target="_blank">https://doi.org/10.5194/amt-12-4495-2019</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib63"><label>Stull(1988)</label><mixed-citation>
      
Stull, R. B.: An introduction to boundary layer meteorology, Kluwer Academic Publishers, <a href="https://doi.org/10.1007/978-94-009-3027-8" target="_blank">https://doi.org/10.1007/978-94-009-3027-8</a>, 1988.​​​​​​​

    </mixed-citation></ref-html>
<ref-html id="bib1.bib64"><label>Taguchi et al.(2002)</label><mixed-citation>
      
Taguchi, S., Iida, T., and Moriizumi, J.: Evaluation of the atmospheric transport model NIRE-CTM-96 by using measured radon-222 concentrations, Tellus B, 54, 250–268, <a href="https://doi.org/10.3402/tellusb.v54i3.16664" target="_blank">https://doi.org/10.3402/tellusb.v54i3.16664</a>, 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib65"><label>Taylor and Lucas(1967)</label><mixed-citation>
      
Taylor, J. A. and Lucas, J.: Atmospheric radon monitor, Tech. Rep. ANL-7220, Argonne National Lab., Ill.,  <a href="https://www.osti.gov/biblio/4405995" target="_blank"/> (last access: 20 December 2024), 1967.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib66"><label>Thomas and Leclare(1970)</label><mixed-citation>
      
Thomas, J. W. and Leclare, P. C.: A study of the two-filter method for radon-222, Health Phys., 18, 113–122, <a href="https://journals.lww.com/health-physics/Abstract/1970/02000/A_Study_of_the_Two_filter_Method_for_Radon_222.2.aspx" target="_blank"/> (last access: 20 December 2024), 1970.​​​​​​​

    </mixed-citation></ref-html>
<ref-html id="bib1.bib67"><label>Tolk et al.(2008)</label><mixed-citation>
      
Tolk, L. F., Meesters, A. G. C. A., Dolman, A. J., and Peters, W.: Modelling representation errors of atmospheric CO<sub>2</sub> mixing ratios at a regional scale, Atmos. Chem. Phys., 8, 6587–6596, <a href="https://doi.org/10.5194/acp-8-6587-2008" target="_blank">https://doi.org/10.5194/acp-8-6587-2008</a>, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib68"><label>van der Laan et al.(2009)</label><mixed-citation>
      
van der Laan, S., Neubert, R. E. M., and Meijer, H. A. J.: Methane and nitrous oxide emissions in The Netherlands: ambient measurements support the national inventories, Atmos. Chem. Phys., 9, 9369–9379, <a href="https://doi.org/10.5194/acp-9-9369-2009" target="_blank">https://doi.org/10.5194/acp-9-9369-2009</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib69"><label>van der Laan et al.(2014)</label><mixed-citation>
      
van der Laan, S., van der Laan-Luijkx, I. T., Zimmermann, L., Conen, F., and Leuenberger, M.: Net CO<sub>2</sub> surface emissions at Bern, Switzerland inferred from ambient observations of CO<sub>2</sub>, <i>δ</i>(O<sub>2</sub>/N<sub>2</sub>), and <sup>222</sup>Rn using a customized radon tracer inversion, J. Geophys. Res.-Atmos., 119, 1580–1591, <a href="https://doi.org/10.1002/2013JD020307" target="_blank">https://doi.org/10.1002/2013JD020307</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib70"><label>Vogel et al.(2012)</label><mixed-citation>
      
Vogel, F., Ishizawa, M., Chan, E., Chan, D., Hammer, S., Levin, I., and Worthy, D.: Regional non-CO<sub>2</sub> greenhouse gas fluxes inferred from atmospheric measurements in Ontario, Canada, J. Integr. Environ. Sci., 9, 41–55, <a href="https://doi.org/10.1080/1943815X.2012.691884" target="_blank">https://doi.org/10.1080/1943815X.2012.691884</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib71"><label>Wada et al.(2013)</label><mixed-citation>
      
Wada, A., Matsueda, H., Murayama, S., Taguchi, S., Hirao, S., Yamazawa, H., Moriizumi, J., Tsuboi, K., Niwa, Y., and Sawa, Y.: Quantification of emission estimates of CO<sub>2</sub>, CH<sub>4</sub> and CO for East Asia derived from atmospheric radon-222 measurements over the western North Pacific, Tellus B, 65, 18037, <a href="https://doi.org/10.3402/tellusb.v65i0.18037" target="_blank">https://doi.org/10.3402/tellusb.v65i0.18037</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib72"><label>Whittlestone and Zahorowski(1998)</label><mixed-citation>
      
Whittlestone, S. and Zahorowski, W.: Baseline radon detectors for shipboard use: Development and deployment in the First Aerosol Characterization
Experiment (ACE 1), J. Geophys. Res.-Atmos., 103, 16743–16751,
<a href="https://doi.org/10.1029/98JD00687" target="_blank">https://doi.org/10.1029/98JD00687</a>, 1998.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib73"><label>Wigand and Wenk(1928)</label><mixed-citation>
      
Wigand, A. and Wenk, F.: Der gehalt der luft an radium-emanation, nach messungen bei flugzeugaufstiegen, Ann. Phys., 391, 657–686,
<a href="https://doi.org/10.1002/andp.19283911302" target="_blank">https://doi.org/10.1002/andp.19283911302</a>, 1928.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib74"><label>Williams et al.(2013)</label><mixed-citation>
      
Williams, A. G., Chambers, S., and Griffiths, A.: Bulk mixing and decoupling of the nocturnal stable boundary layer characterized using a ubiquitous natural tracer, Bound.-Lay. Meteorol., 149,
381–402, <a href="https://doi.org/10.1007/s10546-013-9849-3" target="_blank">https://doi.org/10.1007/s10546-013-9849-3</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib75"><label>Williams et al.(2016)</label><mixed-citation>
      
Williams, A. G., Chambers, S. D., Conen, F., Reimann, S., Hill, M., Griffiths, A. D., and Crawford, J.: Radon as a tracer of atmospheric influences on traffic-related air pollution in a small inland city, Tellus B, 68, 30967, <a href="https://doi.org/10.3402/tellusb.v68.30967" target="_blank">https://doi.org/10.3402/tellusb.v68.30967</a>, 2016.​​​​​​​

    </mixed-citation></ref-html>
<ref-html id="bib1.bib76"><label>Wright(2017)</label><mixed-citation>
      
Wright, A. G.: PMT background, in: The Photomultiplier Handbook, edited by: Wright, A. G., Oxford University Press, ISBN 978-0-19-956509-2,
<a href="https://doi.org/10.1093/oso/9780199565092.003.0006" target="_blank">https://doi.org/10.1093/oso/9780199565092.003.0006</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib77"><label>Wright and Smith(1915)</label><mixed-citation>
      
Wright, J. R. and Smith, O. F.: The variation with meteorological conditions of the amount of radium emanation in the atmosphere, in the soil gas, and in the air exhaled from the surface of the ground, at Manila, Phys. Rev., 5, 459–482, <a href="https://doi.org/10.1103/PhysRev.5.459" target="_blank">https://doi.org/10.1103/PhysRev.5.459</a>,
1915.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib78"><label>Xia et al.(2010)</label><mixed-citation>
      
Xia, Y., Sartorius, H., Schlosser, C., Stöhlker, U., Conen, F., and Zahorowski, W.: Comparison of one- and two-filter detectors for atmospheric <sup>222</sup>Rn measurements under various meteorological conditions, Atmos. Meas. Tech., 3, 723–731, <a href="https://doi.org/10.5194/amt-3-723-2010" target="_blank">https://doi.org/10.5194/amt-3-723-2010</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib79"><label>Yver Kwok et al.(2015)</label><mixed-citation>
      
Yver Kwok, C., Laurent, O., Guemri, A., Philippon, C., Wastine, B., Rella, C. W., Vuillemin, C., Truong, F., Delmotte, M., Kazan, V., Darding, M., Lebègue, B., Kaiser, C., Xueref-Rémy, I., and Ramonet, M.: Comprehensive laboratory and field testing of cavity ring-down spectroscopy analyzers measuring H<sub>2</sub>O, CO<sub>2</sub>, CH<sub>4</sub> and CO, Atmos. Meas. Tech., 8, 3867–3892, <a href="https://doi.org/10.5194/amt-8-3867-2015" target="_blank">https://doi.org/10.5194/amt-8-3867-2015</a>, 2015.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib80"><label>Yver-Kwok et al.(2021)</label><mixed-citation>
      
Yver-Kwok, C., Philippon, C., Bergamaschi, P., Biermann, T., Calzolari, F., Chen, H., Conil, S., Cristofanelli, P., Delmotte, M., Hatakka, J., Heliasz, M., Hermansen, O., Komínková, K., Kubistin, D., Kumps, N., Laurent, O., Laurila, T., Lehner, I., Levula, J., Lindauer, M., Lopez, M., Mammarella, I., Manca, G., Marklund, P., Metzger, J.-M., Mölder, M., Platt, S. M., Ramonet, M., Rivier, L., Scheeren, B., Sha, M. K., Smith, P., Steinbacher, M., Vítková, G., and Wyss, S.: Evaluation and optimization of ICOS atmosphere station data as part of the labeling process, Atmos. Meas. Tech., 14, 89–116, <a href="https://doi.org/10.5194/amt-14-89-2021" target="_blank">https://doi.org/10.5194/amt-14-89-2021</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib81"><label>Zahorowski et al.(2004)</label><mixed-citation>
      
Zahorowski, W., Chambers, S. D., and Henderson-Sellers, A.: Determination of mid-latitude radon-222 flux from the Southern Ocean using atmospheric radon-222 concentration measurements at an island ground station,
International Atomic Energy Agency, <a href="https://inis.iaea.org/collection/NCLCollectionStore/_Public/36/003/36003223.pdf?r=1#page=5&amp;zoom=auto,-15,800" target="_blank"/> (last access: 20 December 2024), 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib82"><label>Zhang et al.(2021)</label><mixed-citation>
      
Zhang, B., Liu, H., Crawford, J. H., Chen, G., Fairlie, T. D., Chambers, S., Kang, C.-H., Williams, A. G., Zhang, K., Considine, D. B., Sulprizio, M. P., and Yantosca, R. M.: Simulation of radon-222 with the GEOS-Chem global model: emissions, seasonality, and convective transport, Atmos. Chem. Phys., 21, 1861–1887, <a href="https://doi.org/10.5194/acp-21-1861-2021" target="_blank">https://doi.org/10.5194/acp-21-1861-2021</a>, 2021.

    </mixed-citation></ref-html>--></article>