<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-19-6037-2026</article-id><title-group><article-title>Spectral versus co-spectral correction of eddy-covariance fluxes: a multi-site assessment across the ICOS network</article-title><alt-title>Spectral vs. co-spectral correction of EC fluxes</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Faurès</surname><given-names>Ariane</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Fratini</surname><given-names>Gerardo</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Nicolini</surname><given-names>Giacomo</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-9800-3351</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Papale</surname><given-names>Dario</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-5170-8648</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Sabbatini</surname><given-names>Simone</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-2950-8911</ext-link></contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Heinesch</surname><given-names>Bernard</given-names></name>
          <email>bernard.heinesch@uliege.be</email>
        <ext-link>https://orcid.org/0000-0001-7594-6341</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>Biosystems Dynamics and Exchanges, TERRA Teaching and Research Center, Gembloux Agro-Bio Tech, University of Liege, Gembloux, Belgium</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>CMCC Foundation – Euro-Mediterranean Center on Climate Change – IAFES Division, Viterbo, Italy</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Department for innovation in biological, agro-food and forest systems (DIBAF), University of Tuscia, Viterbo, Italy</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Bernard Heinesch (bernard.heinesch@uliege.be)</corresp></author-notes><pub-date><day>24</day><month>September</month><year>2026</year></pub-date>
      
      <volume>19</volume>
      <issue>18</issue>
      <fpage>6037</fpage><lpage>6074</lpage>
      <history>
        <date date-type="received"><day>12</day><month>June</month><year>2026</year></date>
           <date date-type="rev-request"><day>7</day><month>July</month><year>2026</year></date>
           <date date-type="rev-recd"><day>29</day><month>August</month><year>2026</year></date>
           <date date-type="accepted"><day>7</day><month>September</month><year>2026</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2026 Ariane Faurès et al.</copyright-statement>
        <copyright-year>2026</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026.html">This article is available from https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d2e144">Accurate correction of high-frequency attenuation remains a critical challenge in eddy-covariance measurements of turbulent gas fluxes. Experimental correction approaches based on either power spectra or co-spectra are widely used, yet their relative behaviour and implications for flux estimates have not been systematically assessed across sites and atmospheric conditions.</p>

      <p id="d2e147">This study presents a multi-site comparison of these two approaches using one year of <inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M2" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> flux data from 38 ecosystem stations of the Integrated Carbon Observation System (ICOS) equipped with a standardized enclosed-path gas analyser setup. To support reproducibility and facilitate future methodological intercomparisons, we additionally provide an open-source and configurable software tool implementing both correction approaches.</p>

      <p id="d2e174">Overall, the ICOS setup exhibited limited high-frequency attenuation, with correction factors generally below 1.2 for <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and occasionally approaching 2 for <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> under humid conditions. For <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, differences between methods remained small after standard turbulence filtering, with cumulative flux differences typically below 2 %. In contrast, <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> corrections showed larger discrepancies, frequently reaching 5 %–10 % on cumulative fluxes. The largest differences occurred under stable atmospheric conditions, at low measurement heights, and under strong attenuation. Results indicate that <inline-formula><mml:math id="M7" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> attenuation is dominated by sensor-separation effects, whereas <inline-formula><mml:math id="M8" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> attenuation is primarily controlled by adsorption–desorption processes within the sampling system.</p>

      <p id="d2e250">The comparison highlights methodological limitations of both approaches. Both methods rely on assumptions regarding spectral similarity, but departures from these assumptions were found to affect gas spectra much more strongly than co-spectra, particularly for <inline-formula><mml:math id="M9" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> under humid conditions. In addition, spectral corrections were frequently affected by high-frequency noise and required dedicated denoising procedures, while sensor-separation effects had to be introduced through analytical formulations. Overall, the co-spectral approach provided more robust and physically consistent results across sites and atmospheric conditions.</p>

      <p id="d2e266">A comparison with fluxes produced by the ICOS Ecosystem Thematic Centre revealed systematic differences that were often larger than those observed between the spectral and co-spectral approaches themselves, especially for <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>. These results demonstrate the effectiveness of setup standardisation across the ICOS network while identifying high-frequency attenuation correction as a remaining source of uncertainty. They also highlight the need for a broader reassessment of this processing step within the ICOS flux-processing pipeline.</p>
  </abstract>
    
<funding-group>
<award-group id="gs1">
<funding-source>Service Public de Wallonie</funding-source>
<award-id>1217769</award-id>
</award-group>
</funding-group>
</article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d2e291">The eddy-covariance (EC) method is the standard micro-meteorological technique to measure energy, momentum and gas turbulent exchanges between the land surface and the atmosphere. By measuring gas concentrations and wind components at high frequency (typically 10–20 Hz), it allows a direct and non-invasive estimation of fluxes at the ecosystem-parcel scale <xref ref-type="bibr" rid="bib1.bibx4 bib1.bibx5" id="paren.1"/>. Despite its widespread application and the continuous technological advances improving the reliability of the instruments, the EC method is still bound to some technical limitations. One major and well-known source of bias is the correction of spectral attenuation of the measured signal, which, if not correctly accounted for, causes a systematic underestimation of the fluxes. Commonly analysed in the frequency domain, attenuation can affect both low- and high-frequency end of the signal spectrum <xref ref-type="bibr" rid="bib1.bibx28 bib1.bibx3 bib1.bibx23 bib1.bibx24" id="paren.2"/>. Signal loss in the high frequencies (low-pass attenuation) results from the physical characteristics of the sampling system like limited sampling time, line averaging, sensor separation and, for (en)closed-path gas analysers, air sampling through tubes and filters. Depending on the setup, the site characteristics, and atmospheric conditions, it can range from a few percent to several tens of percent of the actual flux, and a reliable quantification and correction of this attenuation is a major issue for the flux community <xref ref-type="bibr" rid="bib1.bibx24" id="paren.3"/>.</p>
      <p id="d2e303">Careful instrumentation and mounting set-up choices can reduce signal losses. This is the case with the enclosed-path <inline-formula><mml:math id="M11" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> gas analyser from LI-COR Biosciences Inc. (Lincoln, NE, USA), which has been designed to combine the benefits of open-path and closed-path analysers so that, thanks to its compact size, it can be deployed with a short intake tube (typically <inline-formula><mml:math id="M12" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 1 m), thus reducing losses due to damping of fluctuations in the air sampling tube. This type of instrument is dictated within certain flux tower networks, such as the European ICOS network <xref ref-type="bibr" rid="bib1.bibx12" id="paren.4"><named-content content-type="pre">Integrated Carbon Observation System,</named-content></xref> and the American NEON network (National Ecological Observatory Network, <uri>https://www.neonscience.org</uri>, last access: 20 September 2026). Despite these efforts, spectral corrections are still needed.</p>
      <p id="d2e341">Multiple methods have been developed to quantify and correct the low-pass filtering effect of EC systems. They are commonly categorised as analytical (based on theoretical considerations) or experimental (based on in situ measurements) <xref ref-type="bibr" rid="bib1.bibx24" id="paren.5"/>. Both approaches aim at describing the EC filtering effect through a transfer function <xref ref-type="bibr" rid="bib1.bibx28" id="paren.6"/>, and the flux attenuation through its application to an unattenuated co-spectrum. The analytical method defines the total transfer function as a convolution of individual transfer functions describing each cause of attenuation individually <xref ref-type="bibr" rid="bib1.bibx28 bib1.bibx27 bib1.bibx23" id="paren.7"/>, and is commonly used for anemometer or open-path gas analyser fluxes <xref ref-type="bibr" rid="bib1.bibx24" id="paren.8"/>. Recognition of other sources of spectral losses in more complex EC systems, such as the presence of particle filter(s) and rain caps in the gas sampling system, is necessary. The same applies to the non-neutral spectral characteristics of some gases in (en)closed-path analysers, which are associated with the adsorption and desorption of water molecules in the tube and influenced by air relative humidity. For these sources of flux loss, either no transfer function expressions are available, or the relevant transfer functions depend on aspects that are difficult to parameterise, such as the evolution of tube dirtiness. In all these cases, an experimental approach is recommended <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx21" id="paren.9"/>. In this approach, the transfer function is computed as the ratio of either power spectra or co-spectra of target gas concentration to sonic temperature. The sonic temperature is assumed to be the unattenuated reference, and thus the sensible heat co-spectrum is used for the correction factor estimation <xref ref-type="bibr" rid="bib1.bibx3" id="paren.10"/>.</p>
      <p id="d2e363">The use of power concentration spectra or co-spectra of concentration and vertical wind speed is an important and debated choice. Various studies support the use of power concentration spectra <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx13 bib1.bibx30" id="paren.11"/>. The main arguments are that the inclusion of the vertical wind speed signal does not add any relevant information on the gas spectral attenuation and introduces the need to additionally account for a phase shift which is generally difficult to determine <xref ref-type="bibr" rid="bib1.bibx17" id="paren.12"/>. The power spectra approach is used in the popular EddyPro software package (LI-COR Biosciences, Lincoln, NE, USA), and recommended and applied in the ICOS methodology <xref ref-type="bibr" rid="bib1.bibx40" id="paren.13"/>. However, others defend the use of co-spectra <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx21 bib1.bibx22 bib1.bibx44" id="paren.14"/>, mainly because they are not affected by high-frequency noise and do not require an additional correction term for sensor separation.</p>
      <p id="d2e379">While site-, gas- or instrument-specific studies have been performed to assess the best spectral correction procedure and options <xref ref-type="bibr" rid="bib1.bibx44 bib1.bibx34 bib1.bibx2 bib1.bibx41 bib1.bibx38" id="paren.15"/>, no systematic comparison of spectral vs. co-spectral approach has been done so far.</p>
      <p id="d2e385">In this study we propose a multi-site, data-driven comparison among spectral and co-spectral correction approaches. We based our analysis on the experimental setup adopted in the ICOS network at Class 1 and Class 2 ecosystem stations. We (i) highlight the conditions in which the methods diverge; (ii) quantify and (iii) assess the differences, (iv) highlight the best practices. By doing so, we also give an overall picture of the importance of high-frequency losses for the ICOS EC setup and of the effectiveness of the setup standardisation. Finally, we compare our spectral corrections to the one implemented within the ICOS processing pipeline delivering flux products widely used by the community.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Materials and methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Sites and datasets</title>
      <p id="d2e403">The data used in this study came from 38 ICOS Class 1 and 2 stations measuring <inline-formula><mml:math id="M13" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M14" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> fluxes (Table <xref ref-type="table" rid="TF1"/>). The analysis was based on the 2024 data, the latest dataset available when most of the analyses for this paper were performed. The EC setup is standard at all ICOS sites and it is composed of a LI-7200(RS) (LI-COR Biosciences Inc., Lincoln, NE, USA) infrared gas analyser (IRGA) and one Gill HS-50 or HS-100 (Gill Instruments Ltd., Lymington, UK) 3-D sonic anemometer <xref ref-type="bibr" rid="bib1.bibx36" id="paren.16"/>. All sites were equipped with a standard LI-COR heated 0.73 m-long sampling line of 5.33 mm of inner diameter, a LI-COR rain cap and a 2 <inline-formula><mml:math id="M15" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">m</mml:mi></mml:mrow></mml:math></inline-formula> inlet filter (Swagelok Company, Solon, OH, USA). The flow rate was fixed at each site, at a value between 10 and 16 <inline-formula><mml:math id="M16" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> according to site specifications. The only exception was FR-Gri that switched several times between 12 and 15 <inline-formula><mml:math id="M17" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> until the end of April, after which the flow rate was fixed at 12 <inline-formula><mml:math id="M18" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. The acquisition rate was 20 Hz for 29 sites and 10 Hz for the remaining 9. According to ICOS instructions <xref ref-type="bibr" rid="bib1.bibx39" id="paren.17"/>, the horizontal and vertical distances between the center of the anemometer sensing volume and the center of the sphere that encloses the IRGA raincap should be in the range <inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:mn mathvariant="normal">23.5</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">31</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:mn mathvariant="normal">0</mml:mn><mml:mo>/</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula> cm, respectively. In practice, few exceptions to this rule are encountered (Fig. <xref ref-type="fig" rid="F1"/>).</p>

      <fig id="F1" specific-use="star"><label>Figure 1</label><caption><p id="d2e531">Overview of sites' principal metadata. Panel <bold>(a)</bold> shows the distances between the IRGA and the SA. The vertical separations (rsz in purple) indicate whether the inlet of the IRGA was above (positive) or below    (negative) the centre of the sampling path of the SA. Measurement height and height above zero-plane (<inline-formula><mml:math id="M21" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula>) are displayed in panel <bold>(b)</bold>. The dashed line denotes the <inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> threshold to define high- and    low-measurement-height sites, above and below it, respectively.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f01.png"/>

        </fig>

      <p id="d2e570">The measurement heights across the 38 sites varied over a wide range, reflecting the diversity of ecosystems measured, from peatlands and shrublands to croplands and grasslands, and up to forests (Fig. <xref ref-type="fig" rid="F1"/> and Table <xref ref-type="table" rid="TF1"/>). Stations were classified into two categories, according to their height above the displacement plane (<inline-formula><mml:math id="M23" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula>). After visual inspection of <inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> values and cross-checking with the characterisation of the ecosystem type, a clear distinction emerged between forests, with <inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> above 7 m, and other ecosystems, where <inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> was below 7 m (maximum 4 m). Those two categories were defined as high- and low-measurement-height sites, respectively (HMH and LMH).</p>
      <p id="d2e627">The half-hourly fluxes uncorrected for frequency losses, data quality tests, as well as binned spectra and co-spectra used throughout this study, were computed by the ICOS Ecosystem Thematic Center (ETC), through the standard ICOS pipeline <xref ref-type="bibr" rid="bib1.bibx40 bib1.bibx43" id="paren.18"/>, using EddyPro (version 7.0.9), leading to the 2025 archive product <xref ref-type="bibr" rid="bib1.bibx18" id="paren.19"/>. To compute the fluxes, the following main processing steps were performed: block average to compute the fluctuations around the mean and covariance maximisation to correct for time-lag. Spectra and co-spectra were computed for each half-hour using the Fourier transform and smoothed using fifty exponentially spaced frequency bins.</p>
      <p id="d2e636">The frequency losses were corrected for using either our own implementation, described in the following section, or the standard ICOS pipeline that relies on correction of high-pass attenuations according to <xref ref-type="bibr" rid="bib1.bibx26" id="text.20"/> and correction for low-pass attenuations according to <xref ref-type="bibr" rid="bib1.bibx13" id="text.21"/>, including cross-wind and vertical sensor separation by <xref ref-type="bibr" rid="bib1.bibx15" id="text.22"/> and correction for the anemometer path averaging and time response <xref ref-type="bibr" rid="bib1.bibx28" id="paren.23"/>.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Spectral analysis and correction</title>
      <p id="d2e659">The general principles of an experimental spectral correction procedure are presented in Fig. <xref ref-type="fig" rid="F2"/>. They are generally well established, and follow for both spectral and co-spectral approaches the same steps. The main gas- and method-specific options and parametrizations, which are user-defined, are also highlighted (orange, blue and magenta elements in Fig. <xref ref-type="fig" rid="F2"/>).</p>

      <fig id="F2" specific-use="star"><label>Figure 2</label><caption><p id="d2e668">Flowchart of an experimental spectral correction procedure. On the left side, the general procedure to compute the system cut-off frequency. On the right side, the computation of correction factors to be applied to    half-hourly data to obtain spectrally-corrected fluxes. For both parts, in addition to the main branch, details on potentially impactful parametrisation options (orange), optional procedures (blue), and gas-specific dependencies    (<inline-formula><mml:math id="M27" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> on relative humidity, magenta) are presented. LUT stands for “look-up table” and other acronyms are introduced in the main text.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f02.png"/>

        </fig>

      <p id="d2e690">Only high-frequency spectral losses were considered here. The analysis was performed in the frequency domain, using the (co-)spectra to assess the high-frequency attenuation and compute the flux correction factors. The approach used in this work relied on the use of meteorological data classes and average values. Based on the theorised dependencies found in the literature <xref ref-type="bibr" rid="bib1.bibx28 bib1.bibx27 bib1.bibx3" id="paren.24"/>, wind speed classes were used for both gases and computation steps, namely cut-off frequency (cof) and correction factor (CF) estimation. For <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> only, an additional classification based on relative humidity (RH) was applied, as spectral attenuations of water fluxes have been shown to be driven by the adsorption and desorption processes of water molecules in the sampling tube of the IRGA that varies with RH <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx21" id="paren.25"/>. Finally, for the specific purpose of investigating the theorised dependence of sensor separation CFs to wind direction <xref ref-type="bibr" rid="bib1.bibx15" id="paren.26"/> and for <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> only, an additional assessment by wind direction classes was performed. In all  three cases, a fixed number of classes containing an equal number of data points was used.</p>
      <p id="d2e727">As an initial filtering step common to both cut-off frequency and correction factor computations, only data for which wind speed (WS), wind direction (WD), dimensionless stability parameter (<inline-formula><mml:math id="M30" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>z</mml:mi><mml:mi>L</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula>), sensible heat flux (<inline-formula><mml:math id="M31" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>), tracer flux (<inline-formula><mml:math id="M32" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> or <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> accordingly) and, for <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> only, RH were available were retained. In addition, considering the horizontal geometry of the sonic anemometer used in ICOS, an additional site-specific wind direction filter was applied to remove data affected by flow distortion caused by the horizontal boom supporting the sonic transducers.</p>
<sec id="Ch1.S2.SS2.SSS1">
  <label>2.2.1</label><title>Cut-off frequency computation</title>
      <p id="d2e792">The EC system signal attenuation in the high frequency range can be described with a first-order low-pass filter <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx8" id="paren.27"/>. This transfer function (TF) can be estimated empirically from the ratio of the attenuated to ideal (co-)spectra. Assuming spectral similarity <xref ref-type="bibr" rid="bib1.bibx32" id="paren.28"/>, the equations can be written as:

                  <disp-formula specific-use="gather" content-type="numbered"><mml:math id="M35" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E1"><mml:mtd><mml:mtext>1</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mtext>TF</mml:mtext><mml:mtext>cs</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mtext>CO</mml:mtext><mml:mrow><mml:mi mathvariant="normal">w</mml:mi><mml:mo>,</mml:mo><mml:mover accent="true"><mml:mi mathvariant="italic">χ</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mtext>CO</mml:mtext><mml:mrow><mml:mi mathvariant="normal">w</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">T</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>w</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mi>T</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>w</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mover accent="true"><mml:mi mathvariant="italic">χ</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E2"><mml:mtd><mml:mtext>2</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mtext>TF</mml:mtext><mml:mtext>ps</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mover accent="true"><mml:mi mathvariant="italic">χ</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">T</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mover accent="true"><mml:mi mathvariant="italic">χ</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            where CO<sub>w,T</sub> and <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are, respectively, the sensible heat co-spectra and sonic temperature spectra, considered as ideal (not affected by attenuation), and CO<sub>w,<italic>χ</italic>^</sub> and <inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mover accent="true"><mml:mi mathvariant="italic">χ</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover></mml:msub></mml:mrow></mml:math></inline-formula> the attenuated (co-)spectrum. Both spectra and co-spectra are normalised by their respective (co)variance (<inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">T</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mover accent="true"><mml:mi mathvariant="italic">χ</mml:mi><mml:mo mathvariant="normal" stretchy="false">^</mml:mo></mml:mover><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M42" display="inline"><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>w</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mi>T</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>, <inline-formula><mml:math id="M43" display="inline"><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>w</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mover accent="true"><mml:mi mathvariant="italic">χ</mml:mi><mml:mo stretchy="false" mathvariant="normal">^</mml:mo></mml:mover><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>). As these might also be affected by high-frequency losses, an additional normalisation factor (<inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) is included to ensure spectral similarity <xref ref-type="bibr" rid="bib1.bibx17" id="paren.29"/>.</p>
      <p id="d2e1085">In order to establish the TFs and relative cofs describing each system, only best-quality (co-)spectra were selected, filtering for fluxes and quality flag thresholds as reported in Table <xref ref-type="table" rid="T1"/>. Then, normalized (co-)spectra above a plausibility threshold of 250 were discarded. A final outlier screening discarded any half-hour (co-)spectrum for which, within the 0.005–0.1 Hz band, at least 15 % of frequency bins lay outside pointwise log10-based IQR bounds (<inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:mi>Q</mml:mi><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2.5</mml:mn><mml:mo>×</mml:mo><mml:mtext>IQR</mml:mtext></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:mi>Q</mml:mi><mml:mn mathvariant="normal">3</mml:mn><mml:mo>+</mml:mo><mml:mn mathvariant="normal">2.5</mml:mn><mml:mo>×</mml:mo><mml:mtext>IQR</mml:mtext></mml:mrow></mml:math></inline-formula>) computed across the ensemble.</p>
      <p id="d2e1126">The filtered (co-)spectra were split into constant-size classes of WS, and RH for <inline-formula><mml:math id="M47" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> only. The WS classification accounts for a possible dependence of the cof on WS, which arises from the sensor separation term <xref ref-type="bibr" rid="bib1.bibx28" id="paren.30"/>. In theory, this effect should appear only in the co-spectral approach, since it integrates all attenuation sources into the cof. In contrast, the spectral approach applies the sensor separation effect later, at the CF level (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS2.SSS2"/>). The RH classification accounts for the known dependence of cof on air humidity in the sampling tube and filters, which arises from the adsorption–desorption of water molecules on surfaces <xref ref-type="bibr" rid="bib1.bibx17" id="paren.31"/>. At this point, a quality check was performed, so that if less than 2 (co-)spectra per class were present, the procedure was stopped.</p>
      <p id="d2e1150">Then, (co-)spectra in each class were averaged, resulting in one ideal and one attenuated (co-)spectrum per class.  At this stage, only for the spectral approach was the presence of high-frequency noise in the mean real spectra assessed. When present, noise was removed using the procedure developed by <xref ref-type="bibr" rid="bib1.bibx2" id="text.32"/>, and a noise-free version of the spectra was produced. The details of the denoising procedure are reported in Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>, including some modifications to the original one which showed limitations in multi-site applications.</p>
      <p id="d2e1159">Next, the empirical TF was computed for each class as the ratio of real to ideal normalised (co-)spectra averages (Eqs. <xref ref-type="disp-formula" rid="Ch1.E1"/> and <xref ref-type="disp-formula" rid="Ch1.E2"/>). The spread of the data in the frequency range at which no attenuation occurred, where the ratio was expected to result in a plateau, was checked. After preliminary analysis and visual inspection, the plateau check range was set at 0.021–0.34 Hz. If the coefficient of variation of the data exceeded 1, the TF of that class was discarded for poor quality.</p>
      <p id="d2e1166">A Lorentzian equation was fitted to the valid experimental TFs. For  co-spectral TFs, the Lorentzian was modified according to <xref ref-type="bibr" rid="bib1.bibx34" id="text.33"/> (P21 hereafter), to account for the impact of the phase shift induced by the time-lag covariance maximisation correction on the data:

                  <disp-formula specific-use="gather" content-type="numbered"><mml:math id="M48" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E3"><mml:mtd><mml:mtext>3</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mtext>TF</mml:mtext><mml:mtext>ps</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>f</mml:mi><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E4"><mml:mtd><mml:mtext>4</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mtext>TF</mml:mtext><mml:mtext>cs(P21)</mml:mtext></mml:msub><mml:mo>≈</mml:mo><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:msqrt><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>f</mml:mi><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>
      <p id="d2e1262">Equations (<xref ref-type="disp-formula" rid="Ch1.E3"/>) and (<xref ref-type="disp-formula" rid="Ch1.E4"/>) define the two functions, where ps stands for power spectra, cs for co-spectra, <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the additional normalisation factor, <inline-formula><mml:math id="M50" display="inline"><mml:mi>f</mml:mi></mml:math></inline-formula> [Hz] represents the natural frequency and <inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> [Hz] the characteristic frequency parameter.</p>
      <p id="d2e1298">For the classic Lorentzian approach (Eq. <xref ref-type="disp-formula" rid="Ch1.E3"/>), the cof corresponds to the half-power frequency, at which the TF equals 0.5. In the modified Lorentzian formulation of Peltola (Eq. <xref ref-type="disp-formula" rid="Ch1.E4"/>), the TF equals <inline-formula><mml:math id="M52" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">1</mml:mn><mml:msqrt><mml:mn mathvariant="normal">2</mml:mn></mml:msqrt></mml:mfrac></mml:mstyle></mml:math></inline-formula> at <inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:mi>f</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, and therefore the half-power cut-off frequency is reached at <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:mi>f</mml:mi><mml:mo>=</mml:mo><mml:msqrt><mml:mn mathvariant="normal">3</mml:mn></mml:msqrt><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. Nevertheless, the notation <inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and the acronym cof were retained for consistency with Eq. (<xref ref-type="disp-formula" rid="Ch1.E3"/>) and with the subsequent CF computations. Because of these different definitions, direct comparison of the fitted <inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> parameters was not possible, and the corresponding half-power cut-off frequency was additionally computed and shown for the co-spectral approach, although it was not used for the computation of CFs.</p>
      <p id="d2e1375">Equation (<xref ref-type="disp-formula" rid="Ch1.E4"/>), while being only an approximation of the true transfer function, was considered (fortuitously) approximately correct in the relevant frequency range by <xref ref-type="bibr" rid="bib1.bibx34" id="text.34"/>, diverging from the true TF only under very strong attenuation.</p>
      <p id="d2e1383">The fitting range, chosen after some preliminary analysis and visual inspection, was set for all cases between 0.021 and 10 Hz. This procedure resulted in one cof per WS (and RH) class.</p>
</sec>
<sec id="Ch1.S2.SS2.SSS2">
  <label>2.2.2</label><title>Correction factor computation and fluxes correction</title>
      <p id="d2e1394">The correction factors (CFs) can be computed as the ratio of the unattenuated and the measured flux. Using the properties of co-spectra integrals, and assuming spectral similarity, this can be written as:

              <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M57" display="block"><mml:mrow><mml:mtext>CF</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msubsup><mml:mo>∫</mml:mo><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mo>min⁡</mml:mo></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:msubsup><mml:msub><mml:mtext>CO</mml:mtext><mml:mrow><mml:mi mathvariant="normal">w</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">T</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">d</mml:mi><mml:mi>f</mml:mi></mml:mrow><mml:mrow><mml:msubsup><mml:mo>∫</mml:mo><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mo>min⁡</mml:mo></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:msubsup><mml:msub><mml:mtext>CO</mml:mtext><mml:mrow><mml:mi mathvariant="normal">w</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">T</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:msqrt><mml:mrow><mml:mtext>TF</mml:mtext><mml:mo>(</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:msqrt><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">d</mml:mi><mml:mi>f</mml:mi></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula>

            where <inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:msub><mml:mtext>CO</mml:mtext><mml:mrow><mml:mi mathvariant="normal">w</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">T</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the sensible heat co-spectrum (ideal), TF is the system transfer function as defined in Eqs. (<xref ref-type="disp-formula" rid="Ch1.E3"/>) or (<xref ref-type="disp-formula" rid="Ch1.E4"/>) and their product the attenuated co-spectrum. The lower (<inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mo>min⁡</mml:mo></mml:msub></mml:mrow></mml:math></inline-formula>) and upper (<inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mo>max⁡</mml:mo></mml:msub></mml:mrow></mml:math></inline-formula>) integration limits are determined by the flux averaging interval and half the acquisition frequency (Nyquist frequency), respectively. The use of the square root for the TF is according to <xref ref-type="bibr" rid="bib1.bibx13" id="text.35"/> for the spectral approach, and <xref ref-type="bibr" rid="bib1.bibx34" id="text.36"/> for the co-spectral approach.</p>
      <p id="d2e1545">The computation was performed separately for unstable (<inline-formula><mml:math id="M61" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>z</mml:mi><mml:mi>L</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula> <inline-formula><mml:math id="M62" display="inline"><mml:mo>&lt;</mml:mo></mml:math></inline-formula> 0) and stable (<inline-formula><mml:math id="M63" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>z</mml:mi><mml:mi>L</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula> <inline-formula><mml:math id="M64" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 0) conditions, to account for differences in the position and shape of the reference co-spectra according to the stability regime <xref ref-type="bibr" rid="bib1.bibx19" id="paren.37"/>. First, only good-quality sensible heat co-spectra were selected. Filtering was based on <inline-formula><mml:math id="M65" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> flux value and the quality flags, with different thresholds depending on the stability regime, as reported in Table <xref ref-type="table" rid="T1"/>. For each remaining half-hour, a CF was computed. In order to do so, the TF was first constructed with the cof corresponding to the (RH and) WS of the given half-hour. The CF was then computed according to Eq. (<xref ref-type="disp-formula" rid="Ch1.E5"/>) for each valid averaging period.</p>
      <p id="d2e1599">The full series of half-hourly CF was sorted into (RH and) WS constant-size classes. An outlier removal procedure was applied to avoid bias from extreme values, and then CFs in each class were averaged, resulting in one CF per (RH and) WS class and stability regime.</p>
      <p id="d2e1602">Finally, to account for the fact that the experimentally derived spectral correction factors (CF<sub>sp</sub>) do not include losses associated with spatial separation between the sensing volume of the sonic anemometer and the air sampling inlet, an additional sensor separation term was introduced following <xref ref-type="bibr" rid="bib1.bibx15" id="text.38"/> (Eqs. 16 and 28). Only the cross-wind and vertical components of this correction were considered, as the along-wind displacement is already accounted for through time-lag  compensation. The influence of atmospheric stability, measurement height, and wind direction – the three main controlling factors – on the vertical and cross-wind components of CF<sub>HL09</sub> is illustrated in Appendix <xref ref-type="sec" rid="App1.Ch1.S5"/>. Notably, this correction is independent of gas identity. This procedure yields an additional multiplicative factor that can be applied to the CF<sub>sp</sub>, leading to the total spectral correction expressed as:

              <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M69" display="block"><mml:mrow><mml:msub><mml:mtext>CF</mml:mtext><mml:mtext>sp,tot</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mtext>CF</mml:mtext><mml:mtext>sp</mml:mtext></mml:msub><mml:mo>×</mml:mo><mml:msub><mml:mtext>CF</mml:mtext><mml:mtext>HL09</mml:mtext></mml:msub></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e1663">The entirety of the available fluxes and the meteorological dataset was considered. For both spectral and co-spectral approaches, each half-hour flux was corrected with the CF corresponding to its stability, (RH) and WS conditions, as: <inline-formula><mml:math id="M70" display="inline"><mml:mi>F</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M71" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mtext>unc</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math id="M73" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> CF.</p>
      <p id="d2e1698">The entire spectral analysis and correction procedure was performed using the “<italic>freqcor</italic>” python tool version 1.3.0, which was developed for the purpose of this paper and is publicly available (see section “Code and data availability”).</p>
      <p id="d2e1704">The impact of the two spectral correction approaches on <inline-formula><mml:math id="M74" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M75" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> fluxes (the latter expressed as latent heat flux) was assessed for both their half-hourly fluxes and their cumulative yearly fluxes. To this end, only fluxes measured during periods with good quality and sufficient turbulent conditions were kept. The removal of measurements during periods that violate a number of assumptions underlying the eddy covariance method is a standard procedure in flux processing. In line with common filtering practices, only fluxes meeting the quality criteria reported in Table <xref ref-type="table" rid="T1"/> and corresponding to half-hours with <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> above the site-specific threshold were considered. To avoid adding too much complexity, the missing periods were not gap-filled, and therefore the shown cumulative fluxes should not be interpreted as the true cumulative net ecosystem exchange or water exchange. This was not found to be critical since only relative yearly summed flux differences between methods were used.</p>

<table-wrap id="T1"><label>Table 1</label><caption><p id="d2e1747">Filtering thresholds for different steps of the spectral correction procedure. For cut-off frequency (cof) estimation, the half-hour was filtered if any of the fluxes were lower, in absolute value, than the threshold. When computing correction factors (CF) the half-hours were filtered if the sensible heat flux was smaller (unstable) or bigger (stable) than the thresholds. Quality flags used were the global flag resulting from  <xref ref-type="bibr" rid="bib1.bibx43" id="text.39"/> statistical tests (“DATA_FLAG” in the ICOS L2 product) and the SSITC flag. While stationarity and integral turbulence characteristics were already accounted for within the global flag through related statistical metrics, they were represented differently in SSITC. Including the SSITC flag therefore provided a more conservative filtering approach. Only best-quality data, for which both flags were 0 for all variables, were selected.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Flux thresholds</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M79" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><italic>LE</italic></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M81" display="inline"><mml:mo>[</mml:mo></mml:math></inline-formula>min <inline-formula><mml:math id="M82" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula> max<inline-formula><mml:math id="M83" display="inline"><mml:mo>]</mml:mo></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M84" display="inline"><mml:mo>[</mml:mo></mml:math></inline-formula><inline-formula><mml:math id="M85" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">W</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M86" display="inline"><mml:mo>]</mml:mo></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M87" display="inline"><mml:mo>[</mml:mo></mml:math></inline-formula><inline-formula><mml:math id="M88" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M89" display="inline"><mml:mo>]</mml:mo></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M90" display="inline"><mml:mo>[</mml:mo></mml:math></inline-formula><inline-formula><mml:math id="M91" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">W</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula><inline-formula><mml:math id="M92" display="inline"><mml:mo>]</mml:mo></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">cof</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:mn mathvariant="normal">50</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1000</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">5</mml:mn><mml:mo>*</mml:mo></mml:msup><mml:mo>/</mml:mo><mml:mn mathvariant="normal">100</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M95" display="inline"><mml:mrow><mml:mn mathvariant="normal">30</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1000</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CF<sub>unstable</sub></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:mn mathvariant="normal">30</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1000</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M98" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M99" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">CF<sub>stable</sub></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:mn mathvariant="normal">0</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1000</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M102" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M103" display="inline"><mml:mo>/</mml:mo></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Quality flags</oasis:entry>
         <oasis:entry namest="col2" nameend="col4">All variables and computation steps </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Flag Vitale</oasis:entry>
         <oasis:entry namest="col2" nameend="col4">0 </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Flag SSITC</oasis:entry>
         <oasis:entry namest="col2" nameend="col4">0 </oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d2e1753"><sup>*</sup> Lowered to 2 <inline-formula><mml:math id="M78" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> in an additional run using 8 classes of wind direction, in order to include more data per site.  </p></table-wrap-foot></table-wrap>

</sec>
<sec id="Ch1.S2.SS2.SSS3">
  <label>2.2.3</label><title>Automation and standardisation</title>
      <p id="d2e2138">The spectral analysis and correction procedure described above was developed with the objective of having a unified, automated and standardised approach that could be applied across multiple sites. This turned out to be a challenge, as there were several non-fundamental choices that required the selection of fixed thresholds to be used throughout the procedure. Here, informed decisions were taken after visual inspection of the results of all sites. Thresholds for quality filtering (flux thresholds, quality tests) and fitting ranges, unified across all sites, were chosen to maximise the quality of the data used for the analysis. As a consequence of these choices, one site did not retain a sufficient amount of data to perform the cof analysis, which relies on the most restrictive data selection criteria. This concerned the SE-Deg site for <inline-formula><mml:math id="M104" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, where the <inline-formula><mml:math id="M105" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> fluxes only rarely exceeded the selected threshold.</p>
      <p id="d2e2163">Beyond methodological and process-specific considerations, spectral attenuations also depend on technical, setup-related elements such as flow rate, sampling line heating, filter cleanliness and measurement height above the canopy (see <xref ref-type="bibr" rid="bib1.bibx40" id="altparen.40"/> for more details). Changes in any of these parameters should be accounted for and assessed with a separate spectral analysis time window. For the purpose of this work, we considered that these values remained constant throughout the period analysed. While this was the case for the flow rate and line heating (see above), this cannot be strictly guaranteed for filter cleanliness despite regular filter changes. <inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> might also be subject to changes due to plant development of fast-growing vegetation but this effect is mitigated by regular adjustment of the measurement height according to the ICOS instructions <xref ref-type="bibr" rid="bib1.bibx39" id="paren.41"/>.</p>
</sec>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>CO<sub>2</sub></title>
      <p id="d2e2210">Both normalised average temperature and <inline-formula><mml:math id="M108" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> concentration spectra and normalised average co-spectra of sensible heat flux and <inline-formula><mml:math id="M109" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux for all sites were generally well defined, matched quite well in the medium frequencies and showed the expected behaviour in the high frequencies (Figs. <xref ref-type="fig" rid="FB1"/> and <xref ref-type="fig" rid="FB2"/>). For some sites, especially of the HMH group (black titles in Fig. <xref ref-type="fig" rid="FB2"/>), the presence of white noise on the average gas spectra was observed at a very high frequency, requiring the application of the denoising procedure (Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>). This procedure was performed for at least one class of WS at 21 sites (3 out of the 14 LMH, and 18 out of the 23 HMH). Overall, the spectra and co-spectra were of high quality, allowing a robust determination of TFs and associated cofs.</p>
<sec id="Ch1.S3.SS1.SSS1">
  <label>3.1.1</label><title>Cut-off frequencies</title>
      <p id="d2e2251">The ICOS EC setup shows very good spectral performance, with cofs for <inline-formula><mml:math id="M110" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> generally above 1 Hz (Fig. <xref ref-type="fig" rid="F3"/>). The setup being standardised, cofs are expected to fall in the same range for all sites. This is overall the case, with e.g. the mean, standard deviation and  interquartile range of half-power cofs for the cospectra (no P21) case of 2.1, 0.56 and 0.82 Hz at a WS of 3 <inline-formula><mml:math id="M111" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, and results from both co-spectral and spectral methods showing consistent behaviour, further highlighting the effectiveness of the ICOS setup standardisation.</p>

      <fig id="F3" specific-use="star"><label>Figure 3</label><caption><p id="d2e2286">Spectral and co-spectral <inline-formula><mml:math id="M112" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cut-off frequencies as a function of wind speed class average. The red  bold titles represent the low-measurement-height sites. This distinction is only presented for symmetry with the rest of the document, as cofs are independent of this parameter. Green lines are the results of fitting the classic Lorentzian to the co-spectral-computed TF, and are presented to ease the comparison with the spectral data (red). Blue cof result from the Peltola-modified fit and are used in the rest of the  procedure.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f03.png"/>

          </fig>

      <p id="d2e2306">The co-spectral cofs showed a small positive dependence on WS. This is related to their inclusion of the sensor separation effect. In fact, high-frequency losses for sensor separation are expected to decrease with increasing WS, which translates into an increase of cof value.</p>
      <p id="d2e2310">The spectral cofs are systematically higher than their co-spectral counterparts, consistent with the exclusion of sensor separation from the spectral approach at this stage, and indicating that spectral losses from other sources are minimal with the ICOS setup. The multiple occurrences of spectral cofs outside the displayed range, particularly at low WSs, reflect the difficulty of fitting a TF in these conditions: very little to no loss at high frequency associated with minimal high frequency content yield unstable fit results, always associated with extremely high cofs. The decreasing trend of spectral cofs with WS is therefore likely an artefact. However, this has little practical consequence, as such values correspond to near-zero attenuation and CFs close to 1. The stability of the fit improves at higher WS, where greater high-frequency spectral content results in a better-defined and more robustly fitted TF.</p>
</sec>
<sec id="Ch1.S3.SS1.SSS2">
  <label>3.1.2</label><title>Correction factors</title>
      <p id="d2e2322">The fully empirical CFs for <inline-formula><mml:math id="M113" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are overall low, resulting in a correction of typically less than 20 % (mean median/interquartile range of <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.054</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.020</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.010</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.003</mml:mn></mml:mrow></mml:math></inline-formula> in the unstable case for LMH and HMH, respectively, Fig. <xref ref-type="fig" rid="F4"/>). This result confirms the efficiency of the ICOS setup in terms of spectral losses, already highlighted with the cof results.</p>

      <fig id="F4" specific-use="star"><label>Figure 4</label><caption><p id="d2e2364">Spectral and co-spectral <inline-formula><mml:math id="M116" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> correction factors as a function of wind speed. Data are shown separately for unstable (squares) and stable (triangles) conditions. For the spectral approach, the orange lines show the final CFs including the sensor separation term. The shaded area around the lines corresponds to <inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> SD around the mean. The red bold titles represent the low-measurement-height sites.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f04.png"/>

          </fig>

      <p id="d2e2394">Co-spectral CFs (i.e. co-spectra computed using the co-spectral approach) are larger than spectral ones when the latter do not include the sensor separation term (Fig. <xref ref-type="fig" rid="F4"/>, blue and red lines, respectively). This pattern is consistent across sites, in line with the cof results, and is a consequence of the inclusion of the sensor separation term in the co-spectral approach only. The addition of the theoretical sensor separation  term to CF<sub>sp</sub> (yellow lines in Fig. <xref ref-type="fig" rid="F4"/>) results in higher total CFs for the spectral than for the co-spectral approach, at least for LMH, making the sensor separation term the dominant contribution to the correction for this gas and setup, especially at low WSs.</p>
      <p id="d2e2411">A marked dependence to <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula>, stability and WS is observed for both approaches. LMH (red bold titles in Fig. <xref ref-type="fig" rid="F4"/>) have larger CFs than higher sites. This is expected, as low sites, with more content in high frequencies, lose more signal than the high ones for the same cof (lateral shift of the reference co-spectra peak to higher frequencies for LMH). The <inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> dependence is also explicitly included in the sensor separation theoretical equation (Appendix <xref ref-type="sec" rid="App1.Ch1.S5"/>). Amplified differences between the spectral and co-spectral CFs for LMH are observed.</p>
      <p id="d2e2442">Stable atmospheric conditions show higher CFs than unstable conditions for both approaches. The dependence on atmospheric stability is explicitly expressed in the theoretical sensor separation equation (Appendix <xref ref-type="sec" rid="App1.Ch1.S5"/>), and taken into account in the empirical approach by computing CF separately for stable and unstable conditions. The effect is minor for the fully empirical CFs (co-spectra), with some larger differences visible at very low WSs, generally linked to very stable conditions. However, the full spectral approach shows a strong dependence on the stability parameter for stable conditions (dashed yellow line in Fig. <xref ref-type="fig" rid="F4"/>), leading to larger differences between the methods in such conditions.</p>
      <p id="d2e2449">Finally, both methods show a trend of increasing CF values with WS.</p>
</sec>
<sec id="Ch1.S3.SS1.SSS3">
  <label>3.1.3</label><title>Fluxes</title>
      <p id="d2e2461">First, there are very small to no differences between the half-hourly fluxes corrected by the two methods for HMH (mean median/interquartile range of <inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula> and  <inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:mrow></mml:math></inline-formula> for negative and positive fluxes, respectively), and very small ones for LMH (mean median/interquartile range of <inline-formula><mml:math id="M123" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.08</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.27</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.09</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:mrow></mml:math></inline-formula>) (Fig. <xref ref-type="fig" rid="F5"/>, Table <xref ref-type="table" rid="T2"/>). This reflects the results of unstable CFs, which is expected as <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> filtering was applied and largely removes stable data. Then, when differences are present, they confirm the CF results in their sign, with spectral fluxes generally being bigger (in absolute values) than co-spectral ones.</p>

      <fig id="F5" specific-use="star"><label>Figure 5</label><caption><p id="d2e2582">Boxplot of <inline-formula><mml:math id="M126" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> half-hourly flux differences between the two spectral correction methods, separately for negative and positive fluxes (top) and same figure for the differences between this paper spectral correction method and the ICOS one (bottom). Only quality and <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> filtered fluxes were selected. Box frame <inline-formula><mml:math id="M128" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 25 %–75 % interquartile range (IQR), bold line <inline-formula><mml:math id="M129" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> median, whiskers <inline-formula><mml:math id="M130" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1.5 <inline-formula><mml:math id="M131" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> IQR. The red bold labels represent the low-measurement-height sites. Note the  different scales on the <inline-formula><mml:math id="M132" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axes.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f05.png"/>

          </fig>

      <p id="d2e2649">These half-hour flux differences translate into relative cumulative flux differences of maximum 4.8 %, with 21 sites out of 23 under 1 % for HMH, and maximum 2.1 %, with 8 sites out of 14 under 1.5 % for LMH (Fig. <xref ref-type="fig" rid="F6"/>, Table <xref ref-type="table" rid="T2"/> and Appendix <xref ref-type="sec" rid="App1.Ch1.S3"/>). Note that cumulative <inline-formula><mml:math id="M133" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> fluxes undergo an offsetting process due to the presence of both negative and positive values, which can result in partial neutralisation of differences between methods.</p>

      <fig id="F6" specific-use="star"><label>Figure 6</label><caption><p id="d2e2672">Percentage differences in <inline-formula><mml:math id="M134" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M135" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> cumulated fluxes between the two spectral correction methods and same figure for the differences between this paper spectral correction method and the ICOS    one. The absolute cumulative fluxes were used. The red bold titles represent the low-measurement-height sites.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f06.png"/>

          </fig>

      <p id="d2e2705">Because the ICOS pipeline for frequency corrections relies on a spectral approach, the corrected fluxes are expected to match those obtained using the spectral method implemented in this study. However, this is generally not the case, with differences between the ICOS pipeline and the spectral method implemented here typically larger than for the co-spectral-spectral pair (Figs. <xref ref-type="fig" rid="F5"/> and <xref ref-type="fig" rid="F6"/>). For example, the IQR of the cumulative flux differences reached 5.2 % for LMH (Table <xref ref-type="table" rid="T2"/>). Possible causes of these differences are identified and discussed in Sect. <xref ref-type="sec" rid="Ch1.S4.SS4"/>.</p>

<table-wrap id="T2" specific-use="star"><label>Table 2</label><caption><p id="d2e2719">Summary statistics for <inline-formula><mml:math id="M136" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <italic>LE</italic> flux corrections differences between the two spectral correction methods (<inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:mtext>spectra</mml:mtext><mml:mo>-</mml:mo><mml:mtext>co-spectra</mml:mtext></mml:mrow></mml:math></inline-formula>). In each case the mean median/interquartile range of the metric are provided.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Metric</oasis:entry>
         <oasis:entry colname="col2">Category</oasis:entry>
         <oasis:entry colname="col3">LMH</oasis:entry>
         <oasis:entry colname="col4">HMH</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row rowsep="1">
         <oasis:entry namest="col1" nameend="col4"><inline-formula><mml:math id="M138" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Half-hourly flux difference (<inline-formula><mml:math id="M139" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">Negative fluxes</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.28</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Positive fluxes</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M142" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.02</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.07</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.02</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Relative cumulative flux difference (%)</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M144" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">Δ</mml:mi><mml:mtext>This study</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.3</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1.4</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">Δ</mml:mi><mml:mtext>ETC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.6</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">5.2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.5</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1.3</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry namest="col1" nameend="col4"><italic>LE</italic></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Half-hourly flux difference (<inline-formula><mml:math id="M150" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">W</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">All fluxes</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M151" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.69</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1.03</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.52</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.58</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Relative cumulative flux difference (%)</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">Δ</mml:mi><mml:mtext>This study</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M154" display="inline"><mml:mrow><mml:mn mathvariant="normal">4.5</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3.5</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M155" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2.5</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2.5</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M156" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="normal">Δ</mml:mi><mml:mtext>ETC</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">10.7</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">5.3</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M158" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">7.4</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">6.2</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>H<sub>2</sub>O</title>
      <p id="d2e3166">Normalised average spectra and co-spectra for <inline-formula><mml:math id="M160" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> are generally well-defined and not noisy (Figs. <xref ref-type="fig" rid="FB3"/> and <xref ref-type="fig" rid="FB4"/>). However, <inline-formula><mml:math id="M161" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> spectra show an unexpected behaviour at low frequencies, where they are systematically higher than the ideal ones. The two curves then cross, with the real spectra decreasing faster than the ideal in higher frequencies. It results in a TF that continuously decreases with increasing frequency, without having the typical plateau that precedes the fall linked to spectral losses (not shown). This behaviour is present for all sites for spectra and sometimes for co-spectra as well. It generally worsens with increasing RH values and makes it more challenging to perform a robust fitting procedure, as the Lorentzian equation expects a no-filter zone before the fall with the increasing frequency. This behaviour is acknowledged here, although the Lorentzian formulation is still used for fitting, as it represents the most widely adopted approach, consistent with the <inline-formula><mml:math id="M162" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> case. Moreover, similar deviations from the idealised TF have been reported in a range of atmospheric conditions and are not specific to the ICOS sites and set-up considered here. A more detailed discussion on this aspect is provided in Sect. <xref ref-type="sec" rid="Ch1.S4.SS2"/>.</p>
      <p id="d2e3213">Moreover, as it was the case for <inline-formula><mml:math id="M163" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, several occurrences of white noise are visible on real spectra at high frequency, which implies that the denoising procedure was necessary before cof computation. Indeed it was found that denoising was activated for at least one RH class in 32 sites (10 out of 15 and 22 out of 23 LMH and HMH respectively), with more occurrences observed for high RH and WS classes.</p>
<sec id="Ch1.S3.SS2.SSS1">
  <label>3.2.1</label><title>Cut-off frequencies</title>
      <p id="d2e3235">The dependence of cof to both RH and WS was investigated through a double classification in RH and then WS classes. The former was found to be dominant, with the variability inside each RH class being quite low, as shown by the small error bars in Fig. <xref ref-type="fig" rid="F7"/>. The expected dependence of cof to RH is met for all stations (Fig. <xref ref-type="fig" rid="F7"/>) and is modelled as a negative exponential function, with satisfactory fit results as presented in Appendix <xref ref-type="sec" rid="App1.Ch1.S4"/>. Overall, the same order of magnitude is found across sites, with cof generally well below 1 Hz for dry conditions and decreasing to 0.1 Hz for high humidity conditions. There is a general coherence in the cof results among sites for similar humidity conditions (e.g. mean median/interquartile range of <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.236</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.036</mml:mn></mml:mrow></mml:math></inline-formula> Hz at 60 % of RH for all sites and with the cospectral P21 approach), supporting once again the effectiveness of the standard ICOS setup standardisation. The values found are lower than for <inline-formula><mml:math id="M165" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, which is in line with the higher spectral losses impacting <inline-formula><mml:math id="M166" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> measurements linked to the adsorption/desorption processes affecting the water molecules in the sampling tube.</p>
      <p id="d2e3281">As expected, co-spectral cof (from P21 fitting) are generally lower than spectral ones, but compared to <inline-formula><mml:math id="M167" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> they are much more similar between the two methods, suggesting that the main sources of spectral losses are common to both approaches. It is observed that co-spectral cofs fitted with the non-modified Lorentzian are systematically higher than the spectral values. This outcome is likely linked to the inability of the non-modified Lorentzian to account for the low-pass filtering induced by the time-lag estimation method used, which results in a systematic underestimation of the attenuation <xref ref-type="bibr" rid="bib1.bibx34" id="paren.42"/>.</p>
      <p id="d2e3298">The absence of extreme relative humidity values is true for all sites, with the highest RH class mean rarely exceeding 90 %. This result is inherent to the use of flux filtering thresholds that remove periods with small <italic>LE</italic> fluxes, generally corresponding to high humidity conditions and to the use of equal population bins. In practice, cof found for the highest RH classes are generally stabilised (Fig. <xref ref-type="fig" rid="F7"/>), suggesting that the error on the true cof for unaccounted high humidity conditions would be minor. Moreover, <italic>LE</italic> fluxes at high RH are generally small, which minimises the impact of this bias on the final results.</p>

      <fig id="F7" specific-use="star"><label>Figure 7</label><caption><p id="d2e3312">Spectral and co-spectral <inline-formula><mml:math id="M168" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> cof as a function of relative humidity. Each data point is computed as the average across the 4 WS classes in each RH class. The error bars represent the standard deviation of the wind-speed-class means within each RH class, thus illustrating the variability within each RH class across different WSs. The red bold titles represent the low-measurement-height sites.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f07.png"/>

          </fig>

</sec>
<sec id="Ch1.S3.SS2.SSS2">
  <label>3.2.2</label><title>Correction factors</title>
      <p id="d2e3343">In line with the cofs found, <inline-formula><mml:math id="M169" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> CF values are higher than for <inline-formula><mml:math id="M170" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and both co-spectral and spectral methods yield very similar results (blue and red lines in Fig. <xref ref-type="fig" rid="F8"/>). Because of the higher relative importance of other sources of spectral losses, the addition of the sensor separation term has a relatively minor impact on <inline-formula><mml:math id="M171" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> correction and does not alter the spectral results.</p>
      <p id="d2e3385">In accordance with <inline-formula><mml:math id="M172" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> results, the highest CFs are found in LMH. It also appears more clearly that co-spectral CFs for HMH are bigger than the final spectral ones, which is a consequence of both the small cof (Fig. <xref ref-type="fig" rid="F7"/>) and the low sensor separation term values that have almost no effect on spectral CF.</p>
      <p id="d2e3401">The impact of stability conditions is more marked for <inline-formula><mml:math id="M173" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, and results in a systematically higher CF for stable conditions than unstable, for all methods. Combined with the <inline-formula><mml:math id="M174" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> effect, the highest differences between stable and unstable results appear in the LMH. The low cof values explain the importance of this effect for <inline-formula><mml:math id="M175" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, for which even a small change in the co-spectrum position can lead to significant differences in signal loss.</p>
      <p id="d2e3442">Consistent with <inline-formula><mml:math id="M176" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> results, a CF dependence to WS is found for both methods and stability conditions (in Fig. <xref ref-type="fig" rid="F8"/> for RH values between 55 % and 65 %). However, it is amplified by the fact that the <inline-formula><mml:math id="M177" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> cof does not appear to depend on WS, so that a constant (small) cof is applied to the shifting co-spectrum, thus yielding higher CFs. The additional dependence on RH, already observed in the cof results, is confirmed (Figs. <xref ref-type="fig" rid="FD2"/> and <xref ref-type="fig" rid="FD3"/>) for both methods.</p>

      <fig id="F8" specific-use="star"><label>Figure 8</label><caption><p id="d2e3478">Spectral and co-spectral <inline-formula><mml:math id="M178" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> correction factors as a function of wind speed, for relative humidity between 45 % and 55 %. Data are shown separately for unstable (squares) and stable (triangles) conditions. For the spectral approach, the orange lines show the final CFs including the sensor separation term. The shaded area around the lines corresponds to <inline-formula><mml:math id="M179" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> SD around the mean, a spread that's linked to the additional dependence of water CF to RH. The red bold titles represent the low-measurement-height sites.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f08.png"/>

          </fig>

</sec>
<sec id="Ch1.S3.SS2.SSS3">
  <label>3.2.3</label><title>Fluxes</title>
      <p id="d2e3518">As for <inline-formula><mml:math id="M180" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, the impact of the CFs on the final fluxes is assessed on the latent heat (<italic>LE</italic>) half-hourly fluxes (Fig. <xref ref-type="fig" rid="F9"/>). The mean median/interquartile ranges of the flux difference between the spectra and the co-spectra values are <inline-formula><mml:math id="M181" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.69</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1.03</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M182" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.52</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">0.58</mml:mn></mml:mrow></mml:math></inline-formula> W m<sup>−2</sup> only for LMH and HMH, respectively (Table <xref ref-type="table" rid="T2"/>). However, they reach <inline-formula><mml:math id="M184" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.48</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2.48</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M185" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.14</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">1.42</mml:mn></mml:mrow></mml:math></inline-formula> W m<sup>−2</sup> when selecting only the daytime fluxes (not shown).</p>
      <p id="d2e3616">The relative cumulative flux differences were bigger than for <inline-formula><mml:math id="M187" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, reaching 4.5 % for LMH and <inline-formula><mml:math id="M188" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>2.5 % for HMH (Table <xref ref-type="table" rid="T2"/>, Fig. <xref ref-type="fig" rid="F6"/> and Appendix <xref ref-type="sec" rid="App1.Ch1.S3"/>) and with 3 sites reaching values higher than 7 % and only 15 sites out of 38 having differences lower than 2 % (Fig. <xref ref-type="fig" rid="FC2"/>). It should be noted that, water fluxes being mainly positive, no compensation effect is present, and differences on cumulative sums are fairly representative of the half-hourly differences (confirmed by half-hourly linear regression results, not shown). The LMH and HMH-logic is less marked but consistent with the previous results. In particular, as observed for CFs, in LMH spectral-corrected fluxes are higher than the co-spectral ones, while the opposite is true for HMH.</p>
      <p id="d2e3646">In line with <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, the ICOS-computed <inline-formula><mml:math id="M190" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> fluxes are expected to match the spectral-corrected fluxes, which is however not the case, with differences largely exceeding the inter-method comparison (Fig. <xref ref-type="fig" rid="F6"/> and Appendix <xref ref-type="sec" rid="App1.Ch1.S3"/>). For example, the median and IQR of cumulated flux differences reached <inline-formula><mml:math id="M191" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>10.7 % and 5.3 % for LMH, respectively (Table <xref ref-type="table" rid="T2"/>).</p>

      <fig id="F9" specific-use="star"><label>Figure 9</label><caption><p id="d2e3691">Boxplot of <italic>LE</italic> half-hourly flux differences between the two spectral correction methods (top) and same figure for the differences between this paper spectral correction method and the ICOS one (bottom). Only quality, <inline-formula><mml:math id="M192" display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:mrow></mml:math></inline-formula> filtered and daytime fluxes were selected. Box frame <inline-formula><mml:math id="M193" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 25 %–75 % interquartile range (IQR), bold line <inline-formula><mml:math id="M194" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> median, whiskers <inline-formula><mml:math id="M195" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1.5 <inline-formula><mml:math id="M196" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> IQR. The red bold labels represent the low-measurement-height sites. Note the different scales on the <inline-formula><mml:math id="M197" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axes.</p></caption>
            <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f09.png"/>

          </fig>

</sec>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Sensor separation term</title>
      <p id="d2e3758">The impact of the sensor separation term has been highlighted in the gas-specific CF results (Sect. <xref ref-type="sec" rid="Ch1.S3.SS1.SSS2"/> and <xref ref-type="sec" rid="Ch1.S3.SS2.SSS2"/>). This factor is identical for any gas for a given setup and atmospheric condition. Therefore, its relative contribution depends on the importance of other sources of spectral loss, which are minimal for <inline-formula><mml:math id="M198" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> but more substantial for <inline-formula><mml:math id="M199" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, making the sensor separation term the main contribution to the total CF for <inline-formula><mml:math id="M200" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. <xref ref-type="fig" rid="FE2"/>).</p>
      <p id="d2e3803">The wind direction effect is proper to the sensor separation term, as no other source of spectral loss depends on it, and its impact on CFs is therefore further assessed for both methods. The focus is on <inline-formula><mml:math id="M201" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> results, as for <inline-formula><mml:math id="M202" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> the RH effect was found to dominate over any other dependency.</p>
      <p id="d2e3830">To isolate the wind direction effect, 8 classes of WD were used to compute cofs and CFs for both approaches, selecting unstable conditions and data with WSs between 2 and 3 <inline-formula><mml:math id="M203" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (Fig. <xref ref-type="fig" rid="F10"/>). Because of this additional data filtering, some station datasets had not enough data for a robust computation and were excluded from the analysis. In these conditions, the directional effect dominates the full spectral CF, as expected. Interestingly, a trend with wind direction is observed in the co-spectral results as well, experimentally confirming the model assumption. The magnitude of co-spectral CF is systematically smaller than the theoretical one, but generally in phase with the expected minimum and maximum zones (Fig. <xref ref-type="fig" rid="F10"/>).</p>

      <fig id="F10" specific-use="star"><label>Figure 10</label><caption><p id="d2e3857"><inline-formula><mml:math id="M204" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> co-spectral and spectral correction factors as a function of wind direction, grouped in equal-number-of-points bins. Data are filtered for unstable conditions and wind speeds from 2–3 <inline-formula><mml:math id="M205" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">m</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>. The red bold titles represent the low- measurement-height sites.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f10.png"/>

        </fig>

      <p id="d2e3893">Finally, a systematic pattern of WSs with wind direction is observed across sites (not shown), which results in a cross-dependence that makes it harder to determine which term is the main driver of the CF dependence.</p>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Discussion</title>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Limited but still significant and systematic differences between correction methods</title>
      <p id="d2e3912">The comparison of spectral and co-spectral approaches has been presented through the impact on cut-off frequencies, correction factors, half-hourly fluxes and, finally, cumulative fluxes (not gap-filled). The results show that the differences between the methods for <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> fluxes are systematic, the spectral method having higher CFs and thus amplifying the fluxes. The difference is always very low for HMH due to limited high-frequency signal content and therefore overall very low CFs. It is higher, but still limited, for LMH sites, the worst case being only 0.04 <inline-formula><mml:math id="M207" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for mean median negative fluxes (Table <xref ref-type="table" rid="T2"/>) and the impact on cumulative fluxes is only on average of 1.3 %. It can, however, reach higher values for specific stations (e.g. up to 0.56 <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for IT-BCi, and 4.8 % on cumulative fluxes).</p>
      <p id="d2e3984">The differences get worse for LE, with the spectral correction overestimating the co-spectral one by 2.48 <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">W</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> on average for LMH half-hourly fluxes and by 4.5 % on cumulated fluxes. The overestimation is even reaching 5 %–10 % for 9 out of 38 sites (Fig. <xref ref-type="fig" rid="F6"/>).</p>
      <p id="d2e4006">The same order of magnitude for differences was found by <xref ref-type="bibr" rid="bib1.bibx35" id="text.43"/> in their single site study and here the differences are investigated in terms of dependencies, magnitude and causes, and placed in the larger framework of spectral correction approaches assumptions and limitations.</p>
</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Methodological differences and underlying causes</title>
      <p id="d2e4020">There are fundamental differences in the theory underlying the spectral and co-spectral methods to be considered and discussed.</p>
      <p id="d2e4023">The results across all sites confirm a strong dependence of the CF on the cof, which stresses the importance of correctly characterising the system attenuation behaviour, before combining it with the spectral content to get the CFs. Its computation depends on the quality of the (co-)spectra used to derive the empirical TF, as well as on the choice of the TF to be fitted to the data.</p>
      <p id="d2e4026">The use of Eqs. (<xref ref-type="disp-formula" rid="Ch1.E1"/>) and (<xref ref-type="disp-formula" rid="Ch1.E2"/>) to derive the TF relies on the assumption of spectral similarity in the low frequencies. This hypothesis is generally accepted and widely used in similar correction procedures, in particular when the half-hourly variability that could undermine its validity is levelled out by the use of averages over very specific atmospheric conditions <xref ref-type="bibr" rid="bib1.bibx7" id="paren.44"/>. While well observed for <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, including in this work, multiple works have highlighted an apparent lack of spectral similarity between <inline-formula><mml:math id="M211" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> and temperature spectra <xref ref-type="bibr" rid="bib1.bibx44" id="paren.45"/>. The observed shapes of the <inline-formula><mml:math id="M212" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> spectral averages used in our work follow those findings (Fig. <xref ref-type="fig" rid="FB4"/>), with a lack of spectral similarity in the lower frequencies that appears to worsen with increasing RH (and thus attenuation, not shown), and is more marked for spectra than co-spectra (Appendix <xref ref-type="sec" rid="App1.Ch1.S2"/>). Such dissimilarity has been investigated in various studies and was found to be systematic for water vapour fluxes at low frequencies due to different transport processes affecting the two variables <xref ref-type="bibr" rid="bib1.bibx1" id="paren.46"/>. Besides, in their work, <xref ref-type="bibr" rid="bib1.bibx44" id="text.47"/> link a similar behaviour of gas spectra in the low frequencies to the presence of red noise (i.e., noise dominated by slow, correlated variations at low frequencies). In either case, this result challenges the validity of using spectra for the correction of water vapour attenuation, and the results should be interpreted keeping this limitation in mind.</p>
      <p id="d2e4087">The attenuation is approximated by a first-order filter in the shape of a Lorentzian (Eq. <xref ref-type="disp-formula" rid="Ch1.E3"/>). Although widely used in the literature <xref ref-type="bibr" rid="bib1.bibx42 bib1.bibx11 bib1.bibx13" id="paren.48"/>, many argue that this simple response function does not reflect the complexity of the EC system, and therefore cannot correctly describe its whole damping behaviour <xref ref-type="bibr" rid="bib1.bibx35 bib1.bibx44 bib1.bibx7" id="paren.49"/>. This is particularly true for <inline-formula><mml:math id="M213" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, for which other shapes of TFs (e.g. Gaussian) have been suggested <xref ref-type="bibr" rid="bib1.bibx6" id="paren.50"/>. Similarly, the inclusion of a square root in the TF definition is still debated <xref ref-type="bibr" rid="bib1.bibx7" id="paren.51"/>, and in particular is included in the co-spectral approach based on work relying on a Lorentzian TF shape <xref ref-type="bibr" rid="bib1.bibx34" id="paren.52"/>. The choice of TF shapes and the impact it can have on the spectral-co-spectral comparison is hard to predict and should therefore be tested systematically for both methods and gases.</p>
      <p id="d2e4122">In addition to these general considerations, there are method-specific effects that should be acknowledged. Firstly, the co-spectral approach requires a proper time-lag estimation, the recognition of the low-pass-filtering-induced time lag and consequent phase-shift, and the inclusion of this effect in both the cof and CF estimations. It is included in this work through the use of <inline-formula><mml:math id="M214" display="inline"><mml:msqrt><mml:mtext>TF</mml:mtext></mml:msqrt></mml:math></inline-formula> (in both Eqs. <xref ref-type="disp-formula" rid="Ch1.E4"/> and <xref ref-type="disp-formula" rid="Ch1.E5"/>), which is however an approximation that could fail under very strong attenuations <xref ref-type="bibr" rid="bib1.bibx34" id="paren.53"/>. Co-spectral data are also generally considered noisier and more sensitive to contamination from bad measurements than spectral data, since they depend on two variables <xref ref-type="bibr" rid="bib1.bibx17" id="paren.54"/>. We observed that thanks to very selective high-quality filtering of the data, this risk can be minimised, resulting in good quality, noise-free co-spectra (Figs. <xref ref-type="fig" rid="FB1"/> and <xref ref-type="fig" rid="FB3"/>). In rare instances where lower-quality data pass all screenings, the impact generally depends on total attenuation. In our analysis, it resulted in co-spectral outputs being more impacted than spectral ones for <inline-formula><mml:math id="M215" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. This is because the spectral cofs, not including the sensor separation effect, are so high that a lower resolution of the TF has little to no impact, whereas this is not the case for co-spectra.</p>
      <p id="d2e4159">On the other hand, the presence of noise is observed for spectra, mostly in the highest frequencies when the real signal is low (Figs. <xref ref-type="fig" rid="FB2"/> and <xref ref-type="fig" rid="FB4"/>). Using an automatic procedure (described in Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>), noise was found and removed at 58 % and 84 % of sites for <inline-formula><mml:math id="M216" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M217" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, respectively. In line with similar observations <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx2 bib1.bibx44" id="paren.55"/>, these results confirm that denoising plays a central role in the spectral method, and that addressing the limitations of the current procedure (e.g. assumption of white noise) and stabilising a robust approach are necessary <xref ref-type="bibr" rid="bib1.bibx2" id="paren.56"/>.</p>
      <p id="d2e4199">Finally, we showed that <inline-formula><mml:math id="M218" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> attenuation is dominated by the sensor separation effect, the theoretical term that corrects for this effect constituting on average 89 % of the total spectral CF (across sites and for unstable conditions) (Fig. <xref ref-type="fig" rid="FE2"/>). For the spectral approach, this means that the final CF rely heavily on the theoretical equation defining this specific term. This is questionable for an approach that is initially intended to be mainly experimental. In these conditions, the applicability of the chosen theoretical approach to define the sensor separation CF should be addressed. The method developed by <xref ref-type="bibr" rid="bib1.bibx15" id="text.57"/> uses an exponential model to estimate the attenuation as a function of the co-spectral peak frequency (parameterised according to stability) and the distance between the sensors (depending on wind direction). If the modelled peak frequency does not reflect the turbulent characteristics of the site, the estimated attenuation could be biased <xref ref-type="bibr" rid="bib1.bibx22" id="paren.58"/>. Here, a comparison with the co-spectra results revealed that CF<sub>HL09</sub> are far more sensitive to atmospheric stability than the experimental CF, reaching unrealistically high values under stable conditions (Fig. <xref ref-type="fig" rid="F4"/>). This is consistent with findings from other studies <xref ref-type="bibr" rid="bib1.bibx22 bib1.bibx35" id="paren.59"/>, and whilst the consequences on the fluxes surviving the traditional flux filtering are minimised (the <inline-formula><mml:math id="M220" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> filtering removes most stable conditions), it is considered methodologically questionable. Moreover, a dependence of co-spectral CF on wind direction was found, generally in phase but with a smaller amplitude than the modelled behaviour (Fig. <xref ref-type="fig" rid="F10"/>). This result experimentally confirms the theoretical framework, though only partially its application, and validates the co-spectral method in its ability to account for all sources of attenuation. It further suggests that explicitly including the directional effect in the co-spectral approach could improve CF computation. However, in practice, this is not always feasible: the additional classification, combined with site-specific wind roses, would further fragment the dataset, potentially leaving insufficient data to reliably apply the procedure. Given this limitation – and considering that a dependence between WD and WS is also observed (Fig. <xref ref-type="fig" rid="FE3"/>), and that WS distribution at a given site is typically broader and more uniform than that of wind direction – WS classification alone is deemed sufficient for the co-spectral approach.</p>
      <p id="d2e4254">Common to the two approaches is the choice of the reference co-spectrum. Here, the fully empirical method is used, and therefore the measured sensible heat co-spectrum is considered ideal. However, it should be noted that what to use as an unattenuated reference is an ongoing discussion in the literature, with works suggesting that the empirical choice is not the wisest and that theory-based parametrisations of ideal co-spectra should be used <xref ref-type="bibr" rid="bib1.bibx41" id="paren.60"/>.</p>
      <p id="d2e4260">All the limitations presented above can lead to uncertainties at different levels of the correction procedure. The errors linked to this effect are systematic, and an estimation of the sources and magnitude of those uncertainties at each step of the correction procedure is therefore necessary to assess the significance of the differences found.</p>
      <p id="d2e4263">Overall, our results show spectra characterised by a lack of spectral similarity in the low frequencies for <inline-formula><mml:math id="M221" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, increasing with RH, and by the presence of (assumed) white noise in the high frequencies, also for strong attenuations mostly. Even if the latter is accounted for with an ad hoc procedure, both contribute to increase the uncertainty in the TF definition and cof computation. On the other hand, concerns related to the quality of the co-spectral data are minimised, leading to stable results across sites. In this context, and for the very specific ICOS standard setup measuring <inline-formula><mml:math id="M222" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M223" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, we recommend using the co-spectral approach.</p>
</sec>
<sec id="Ch1.S4.SS3">
  <label>4.3</label><title>Dependence on gas and atmospheric conditions</title>
      <p id="d2e4311">Differences between methods were found to be more important for <inline-formula><mml:math id="M224" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> than for <inline-formula><mml:math id="M225" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, at least on cumulative fluxes (Table <xref ref-type="table" rid="T2"/> and Figs. <xref ref-type="fig" rid="FC1"/> and <xref ref-type="fig" rid="FC2"/>). In this specific metric, the absence of positive/negative offset effects compared to <inline-formula><mml:math id="M226" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> can play a role. But more important differences between methods can already be found on CFs (Figs. <xref ref-type="fig" rid="F4"/> and <xref ref-type="fig" rid="F8"/>). This is also due to higher CFs for <inline-formula><mml:math id="M227" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>. While <inline-formula><mml:math id="M228" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux attenuation is dominated by the sensor separation effect, adsorption and desorption of water molecules on the sampling tube seem to dominate the high-frequency losses for <inline-formula><mml:math id="M229" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> (Fig. <xref ref-type="fig" rid="F7"/>). This phenomenon results in a strong dependence to atmospheric RH and overall larger attenuations than for <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, both observations in line with the existing literature <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx21 bib1.bibx6 bib1.bibx13" id="paren.61"/>. For the spectral approach, these effects translate in a decreased relative dependence of the final spectral-computed CF to sensor separation (Fig. <xref ref-type="fig" rid="FE2"/>).</p>
      <p id="d2e4416">For both gases, differences between methods increase with stability and WS, and decrease with measurement height (Figs. <xref ref-type="fig" rid="F4"/> and <xref ref-type="fig" rid="F8"/>). It is known that these variables are linked to a shift of the reference co-spectrum peak towards the higher frequencies (for an increase in <inline-formula><mml:math id="M231" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>z</mml:mi><mml:mi>L</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula> and WS and a decrease in <inline-formula><mml:math id="M232" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula>) <xref ref-type="bibr" rid="bib1.bibx19 bib1.bibx10" id="paren.62"/>, which yields greater CFs for the same cof and therefore an amplification of the differences between methods.</p>
      <p id="d2e4449">Atmospheric stability, and in particular the occurrences of stable  conditions, play an important role through a double effect. Firstly, the shift of the reference co-spectrum and its consequences mentioned above are observed on both methods and gases, but the level of the impact on the CFs and then fluxes depends on the cof value – the smaller the cof, the larger the impact of a shift towards the high-frequency range. Secondly, for the spectral approach only, a direct effect arises from the theoretical sensor separation term, which is highly sensitive to <inline-formula><mml:math id="M233" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>z</mml:mi><mml:mi>L</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula> under stable conditions. This leads to systematically large final CFs at low WSs, typically associated with stable episodes (Figs. <xref ref-type="fig" rid="F4"/> and <xref ref-type="fig" rid="F8"/>) and that cannot be reproduced by the fully experimental co-spectral approach.</p>
      <p id="d2e4467">The analysis of the impact of spectral corrections on fluxes is performed on <inline-formula><mml:math id="M234" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-filtered fluxes. The filtering is applied to reflect the standard EC-flux post-processing pipeline that requires the removal of non-representative fluxes prior to their gapfilling <xref ref-type="bibr" rid="bib1.bibx37 bib1.bibx33" id="paren.63"/>. In practice, the removal of conditions considered as not fully turbulent largely filters stable conditions <xref ref-type="bibr" rid="bib1.bibx3" id="paren.64"/>. Therefore, one major source of differences is removed, and, in the end, the impact of stable conditions on the final fluxes is minor (Figs. <xref ref-type="fig" rid="FC1"/> and <xref ref-type="fig" rid="FC2"/>).</p>
      <p id="d2e4492">In line with the work by <xref ref-type="bibr" rid="bib1.bibx38" id="text.65"/>, higher measurement heights above displacement level (<inline-formula><mml:math id="M235" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula>) yield lower CFs, which is again attributed to the shift of the reference co-spectrum towards higher frequencies. This effect is so important that, for stations that were categorised as “high-measurement-height sites” (23 out of 38), and that in practice cover all forest stations, CFs are so low that the high-frequency loss correction could probably be simply skipped and differences between methods for <inline-formula><mml:math id="M236" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are so low that they cannot be appreciated (Fig. <xref ref-type="fig" rid="FC1"/>). The situation is slightly different for <inline-formula><mml:math id="M237" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, where if the impact of <inline-formula><mml:math id="M238" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>-</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> is clear on CF results (Fig. <xref ref-type="fig" rid="F8"/>), it is less so on (cumulative) fluxes (Figs. <xref ref-type="fig" rid="F9"/> and <xref ref-type="fig" rid="FC2"/>), where differences between methods are enhanced by the larger magnitude of the CFs, including for HMH. These results highlight the importance of installing EC systems at the highest possible position, subject to considerations on the extension of the footprint in the target surface <xref ref-type="bibr" rid="bib1.bibx29 bib1.bibx36" id="paren.66"/>, and at the same time stresses the importance of an accurate correction procedure for towers measuring close to the canopy.</p>
      <p id="d2e4558">In this work, a WS classification is applied at the cof level to account for the dependence of cof on WS induced by sensor separation, as theorised by <xref ref-type="bibr" rid="bib1.bibx28" id="text.67"/>. Although this expected dependence is typically not accounted for in the literature, it is systematically observed for <inline-formula><mml:math id="M239" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in our dataset, where the co-spectral cof increases with WS (Fig. <xref ref-type="fig" rid="F3"/>). This behaviour is consistent with the dominance of the sensor separation term in the overall correction. The resulting dependence of CFs on WS reflects the interplay of two competing effects. On the one hand, the sensor separation contribution is not expected to introduce a strong WS dependence, as the shift of the reference co-spectrum peak to higher frequencies is offset by the corresponding adjustment in cof. On the other hand, other sources of spectral losses, associated with a constant cof, should lead to a positive relationship between CF and WS. In the co-spectral approach, these two effects are accounted for simultaneously, yielding the observed trend. For the spectral approach, the separation of these contributions would suggest a stronger dependence of the non-sensor-separation term on WS (red lines in Fig. <xref ref-type="fig" rid="F4"/>), which is not observed. However, this apparent discrepancy can be explained by the very high cof values characterising the spectral method. Such high cofs result in CFs close to unity, making any dependence on WS difficult to detect. Unlike for cofs, this dependence of CFs on WS is consistent with standard practices in the literature, where explicit parameterisations are commonly implemented in flux correction approaches <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx13" id="paren.68"/>.</p>
      <p id="d2e4582">In contrast, for <inline-formula><mml:math id="M240" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, the application of a WS classification proves unnecessary. No clear relationship between cof and WS is observed for either method (Fig. <xref ref-type="fig" rid="F7"/>). Instead, spectral losses are dominated by the effect of RH, even when using an enclosed-path analyser with a relatively short tube.</p>
</sec>
<sec id="Ch1.S4.SS4">
  <label>4.4</label><title>Effectiveness of the standardised use of the enclosed-path gas analyser and comparison with ICOS flux data</title>
      <p id="d2e4608">One important finding emerging from the analysis is the efficiency of the ICOS setup in terms of limiting high-frequency losses. Regardless of the method, CFs of half-hourly fluxes are overall below 1.2 and mostly below 1.1 for unstable conditions (20 % to 10 % correction respectively) for <inline-formula><mml:math id="M241" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (Fig. <xref ref-type="fig" rid="F4"/>), and reach a maximum of 2 for <inline-formula><mml:math id="M242" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> for conditions with high RH and strong winds (Fig. <xref ref-type="fig" rid="F8"/>, and more in detail in Fig. <xref ref-type="fig" rid="FD3"/>). These results are in line with other values reported in the literature for the LI-7200 <xref ref-type="bibr" rid="bib1.bibx13 bib1.bibx35 bib1.bibx34" id="paren.69"/>. They also confirm the superior performance of the enclosed-path analyser compared to closed-path systems for <inline-formula><mml:math id="M243" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in terms of spectral losses. The improvement is less obvious for <inline-formula><mml:math id="M244" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, comparison of obtained cofs for <inline-formula><mml:math id="M245" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> between our study and closed-path studies on DK-Sor, FI-Hyy and BE-Lon respectively <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx21 bib1.bibx6" id="paren.70"/> showing no major differences. Moreover, high-frequency attenuations are shown to be overall coherent across sites (Figs. <xref ref-type="fig" rid="F3"/> and <xref ref-type="fig" rid="F7"/>), which highlights the effectiveness of the ICOS standardisation. This is particularly relevant in the context of an expanding network of stations whose main objective is delivering very high-quality data, as the choice of standard instruments for the EC systems facilitates inter-site comparisons and the consequent generalisation of potential findings at the network level directly. However, despite the technical improvements, the spectral correction is still a necessary step in the computation of final fluxes, as its inclusion can have an impact on the discussion around major unsolved topics concerning EC fluxes such as energy balance un-closure and reliability of long-term carbon budgets <xref ref-type="bibr" rid="bib1.bibx25 bib1.bibx31 bib1.bibx20" id="paren.71"/>.</p>
      <p id="d2e4693">While relying on the ICOS-ETC products for input data, the frequency-loss correction procedure performed in this work is independent from the ICOS processing pipeline <xref ref-type="bibr" rid="bib1.bibx40" id="paren.72"/>. This allowed us to build a customisable approach, not bounded to the options selected at the network level, where we could choose, based on an extensive literature review, some of the most up-to-date approaches to correct for high-frequency losses. Nevertheless, it remains interesting to compare our results with a recent ICOS network data release <xref ref-type="bibr" rid="bib1.bibx18" id="paren.73"/>, considered a benchmark of high quality and standardisation and as such widely used around the world (<ext-link xlink:href="https://doi.org/10.18160/S6HM-CP8Q" ext-link-type="DOI">10.18160/S6HM-CP8Q</ext-link> for download statistics of the multi-sites archive, <inline-formula><mml:math id="M246" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 1000 on 1 May 2026).</p>
      <p id="d2e4712">It was shown that differences in cumulative fluxes between our spectral approach and ICOS results are present, mostly higher than the differences between the two correction methods, and systematically leaning towards greater values (in absolute terms) for ICOS-ETC fluxes. For cumulative <inline-formula><mml:math id="M247" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> fluxes, they are significant at LMH, with 6 sites out of 14 showing differences higher than 4 % and smaller for HMH (5 out of 23 sites with differences higher than 4 %) (Fig. <xref ref-type="fig" rid="FC1"/>). For cumulative <inline-formula><mml:math id="M248" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> fluxes, differences are larger, with 11 out of 15 LMH and 9 out of 23 HMH showing differences higher than 10 %, with a total of 6 cases of very large differences (higher than 20 %) (Figs. <xref ref-type="fig" rid="F6"/> and <xref ref-type="fig" rid="FC2"/>).</p>
      <p id="d2e4745">The impact on the fluxes is a direct consequence of the divergences between the CFs from the two approaches (not shown). These differences reflect differences between the spectral correction approaches: first an additional theoretical equation is applied to ICOS data to correct for low-frequency losses <xref ref-type="bibr" rid="bib1.bibx26" id="paren.74"/>. Another equation is then applied in the high-frequency losses procedure to account for the anemometer losses for path averaging and time response <xref ref-type="bibr" rid="bib1.bibx28" id="paren.75"/>. Then, for the sensor separation term, the Eq. (13) from the reference paper of <xref ref-type="bibr" rid="bib1.bibx15" id="paren.76"/> is used instead of Eq. (16) in the present paper. All of this results in higher CF values. Then, thresholds for flux filtering and TF fitting range are different, and the denoising procedure is applied using a fixed frequency threshold. Moreover, the use of the <inline-formula><mml:math id="M249" display="inline"><mml:msqrt><mml:mtext>TF</mml:mtext></mml:msqrt></mml:math></inline-formula> to describe the attenuation of sensible heat co-spectra and compute CFs (Eq. <xref ref-type="disp-formula" rid="Ch1.E5"/>) in the spectral procedure is supported by the latest works <xref ref-type="bibr" rid="bib1.bibx34 bib1.bibx7" id="paren.77"/>, but in contradiction with the ICOS pipeline <xref ref-type="bibr" rid="bib1.bibx40" id="paren.78"/> and EddyPro latest version <xref ref-type="bibr" rid="bib1.bibx16" id="paren.79"><named-content content-type="pre">see</named-content></xref>. This choice has a direct effect on the CF values, and has been shown to cause a bias of up to 10 % on fluxes by <xref ref-type="bibr" rid="bib1.bibx34" id="text.80"/>. A more detailed investigation was considered beyond the scope of our work. However, these results highlight the need for further investigation of the causes and the assessment of the impact of the different minor choices on the results.</p>
      <p id="d2e4783">In this context, it is important to point out that one major challenge faced by networks is the need for a procedure as automated and standard as possible, minimising manual processing and its associated subjectivity and workload. Thanks to the standardisation of the experimental set-up across sites, visual inspection and manual checks nevertheless made it possible to define consistent choices that could be applied uniformly to all sites. However, these steps still rely on user-defined decisions and therefore remain a source of subjectivity, whereas they should ideally be replaced by robust automated procedures. Moreover, performing the analysis on a multi-site dataset spanning a wide range of meteorological conditions and ecosystems made it possible to highlight both the difficulties and the limitations of a fully automated approach, as well as the key areas requiring further development. In particular, additional efforts should be made: to improve the filtering procedure by replacing the current uniform flux thresholds with criteria based on the signal-to-noise ratio, thereby allowing the inclusion of sites exhibiting small but well-resolved gas exchanges; to further develop the denoising procedure, for which the method by <xref ref-type="bibr" rid="bib1.bibx2" id="text.81"/> should be tested and validated on a multi-site dataset; and to develop a robust method for fitting threshold selection.</p>
</sec>
<sec id="Ch1.S4.SS5">
  <label>4.5</label><title>Extension to other set-ups</title>
      <p id="d2e4798">This study was limited to enclosed-path gas analysers, and therefore its conclusions are limited to this configuration. Other set-ups do exist, involving open-path or closed-path gas analysers, the latter being often used for other gases than <inline-formula><mml:math id="M250" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, in particular <inline-formula><mml:math id="M251" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M252" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> where also <inline-formula><mml:math id="M253" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> is measured. For EC systems based on open-path analysers, high-frequency attenuation are intrinsically small, limiting the importance of the specific correction method. For closed-path systems, however, especially when long sampling tubes and limited flow rates are involved, the potential differences between spectral and co-spectral approaches to correcting high-frequency losses could be important and have not been addressed here. Differences related to sensor separation are expected to be more limited, even for non <inline-formula><mml:math id="M254" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, because the increasing importance of tube effects may overwhelm the sensor-separation effect, as observed for <inline-formula><mml:math id="M255" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> in the present study. On the other hand, noise removal, which is already potentially problematic with enclosed-path analysers and is specific to the spectral approach, could become more critical as stronger tube-related attenuation increases the likelihood of noise at the high-frequency end of the spectra. A similar multi-site study, facilitated by the availability of a standardised dataset based on such analyser configurations, would therefore be valuable.</p>
</sec>
</sec>
<sec id="Ch1.S5" sec-type="conclusions">
  <label>5</label><title>Conclusions</title>
      <p id="d2e4886">We analysed and compared spectral and co-spectral empirical approaches to correct for high-frequency losses affecting eddy covariance measured fluxes. The two methods coexist in the literature, but a systematic, multi-site comparison was lacking until now. We focused our analysis on the enclosed-path gas analyser, widely used in global networks like ICOS for measuring <inline-formula><mml:math id="M256" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M257" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d2e4913">We showed that the correction factors are ranging from 1–1.2 for <inline-formula><mml:math id="M258" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and from 1–2 for <inline-formula><mml:math id="M259" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, and consistent across sites. This highlighted the overall good spectral performance of the enclosed path analyser, at least for <inline-formula><mml:math id="M260" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, as well as the effectiveness of the choice of setup standardisation. Nevertheless, we found that differences between the methods exist, and that they depend on atmospheric stability, measurement height and attenuation level. The biggest differences were found for stable conditions, low-measurement-height sites (LMH) and <inline-formula><mml:math id="M261" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, corresponding to situations with the largest contribution of small-scale eddies to the flux and the largest attenuations. We assessed the impact of the two correction methods on quality and <inline-formula><mml:math id="M262" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-filtered fluxes, which mimics the standard post-processing filtering and rejects most stable conditions. We found that LMH sites (crops, grasslands, non-forested peatlands) have the highest differences, with absolute differences on half-hourly <inline-formula><mml:math id="M263" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (LE) fluxes that were on average of 0.04 <inline-formula><mml:math id="M264" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">mol</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (2.48 <inline-formula><mml:math id="M265" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">W</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">m</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) and with relative differences on cumulative <inline-formula><mml:math id="M266" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (<italic>LE</italic>) fluxes that were under 2 % (5 %), the spectral correction enhancing more the fluxes than the co-spectral one.</p>
      <p id="d2e5046">We highlighted the importance of the sensor separation effect, and found that the use of its theoretical formulation in the spectral approach leads to unrealistic values in stable conditions. Moreover, when using spectra, we observed that a robust denoising procedure was necessary, and additionally that spectral similarity often failed, especially for <inline-formula><mml:math id="M267" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>. Because of these reasons, we suggest prioritising the co-spectral approach with this specific experimental setup.</p>
      <p id="d2e5062">Comparison of our spectral-corrected fluxes with those delivered by the ICOS network showed more important differences, reaching on average 1.6 % and 10.7 % for <inline-formula><mml:math id="M268" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M269" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, respectively, with some stations showing differences that can reach 10.3 % and 32.1 %, respectively, calling for a revisiting of those corrections at the network level.</p>
      <p id="d2e5090">Finally, we highlighted the challenges involved in developing a fully automated approach, while emphasizing its importance for network-scale processing pipelines. We therefore recommend that further research be dedicated to this topic. To support future developments, the attenuation analysis and correction code has been made openly available to the community. The code is designed to be broadly applicable across  experimental setups and trace gases, while remaining easy to configure. As such, it provides a flexible framework for investigating (co-)spectral  corrections, which remain among the most challenging aspects of turbulent flux calculations.</p>
</sec>

      
      </body>
    <back><app-group>

<app id="App1.Ch1.S1">
  <label>Appendix A</label><title>Denoising procedure for spectral approach</title>
      <p id="d2e5104">The denoising procedure applied to average spectra before computing the transfer function follows the work of <xref ref-type="bibr" rid="bib1.bibx2" id="text.82"/> (A21 hereafter). They developed a TF equation (Eq. 6 in their paper) that explicitly includes a term for the white noise affecting the high frequencies:

          <disp-formula id="App1.Ch1.S1.E7" content-type="numbered"><label>A1</label><mml:math id="M270" display="block"><mml:mrow><mml:mi>f</mml:mi><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="italic">χ</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="italic">χ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mi>f</mml:mi><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">T</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>f</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi mathvariant="normal">T</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:mfrac></mml:mstyle><mml:msub><mml:mi>F</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>+</mml:mo><mml:mo>(</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">π</mml:mi><mml:mi>f</mml:mi><mml:mi mathvariant="italic">τ</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>+</mml:mo><mml:mtext>fb</mml:mtext><mml:mspace linebreak="nobreak" width="0.33em"/><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        where <inline-formula><mml:math id="M271" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula> <inline-formula><mml:math id="M272" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math id="M273" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mi mathvariant="italic">π</mml:mi><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula> is the filter time constant (in seconds) and fb is the linear term that accounts for the presence of white noise in the high frequencies. <xref ref-type="bibr" rid="bib1.bibx2" id="text.83"/> use the equation to directly compute the system cof while taking into account the high-frequency noise. Their procedure is supposed to be parameter-free, facilitating automation of the processing chain. In our work, however, we found that this approach gave unexpected results in some cases with low high-frequency noise. Therefore, an additional noise assessment step is performed, so that denoising is applied only if the presence of noise is significant. In practice, according to the acquisition frequency, the noise check is done starting at 5 or 3 Hz, for 20 or 10 Hz acquisitions respectively. In log-log scale, a linear regression is performed on the attenuated power spectrum data points that are after the corresponding threshold. Only if the slope of the linear regression is higher than 0.2 is the denoising procedure performed.</p>
      <p id="d2e5239">Multi-site comparison of the cof results from the A21 unified procedure and from the procedure developed for this work (on denoised data) showed systematic differences between the two methods. Because the denoising procedure only concerns spectra, and because it is only applied in some cases (after noise-significance check), the systematic differences resulted in an additional class uncertainty difficult to account for. Therefore, it was decided to split the procedure into two steps, so that the actual fitting and cof computation procedure is coherent throughout all the work, for all sites, methods and gases. In practice, first, Eq. (<xref ref-type="disp-formula" rid="App1.Ch1.S1.E7"/>) is fitted to the data. The fitting range of the equation is 0.021–10 Hz (the same as the global procedure). The fit results are: a cof, a normalisation factor, a noise slope and intercept with the <inline-formula><mml:math id="M274" display="inline"><mml:mi>y</mml:mi></mml:math></inline-formula> axis. Then, only the noise-related parameters are used, to remove noise from the initial spectrum. The resulting denoised spectrum is returned and is used in the classic global procedure to compute a final cof.</p>
      <p id="d2e5251">Overall, noise was detected on 21 out of 37 sites for <inline-formula><mml:math id="M275" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and in particular for HMH, where the decreased real content in the higher frequencies allows the emergence of noise. For <inline-formula><mml:math id="M276" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, in line with an increased spectral attenuation, noise removal was activated for 32 sites out of 38, on multiple classes for each site. It was not always a white noise but the <xref ref-type="bibr" rid="bib1.bibx2" id="text.84"/> procedure, which is restricted to the white noise case, was still applied in the absence of an alternative. We conclude that further work is needed on the denoising aspects if the spectral procedure were to be preferred.</p>
</app>

<app id="App1.Ch1.S2">
  <label>Appendix B</label><title>(co-)spectra averages</title>
      <p id="d2e5290">Example co-spectra of kinematic sensible heat (<inline-formula><mml:math id="M277" display="inline"><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>w</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mi>T</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>) and <inline-formula><mml:math id="M278" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux (<inline-formula><mml:math id="M279" display="inline"><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>w</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mi>c</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>) or <inline-formula><mml:math id="M280" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> flux (<inline-formula><mml:math id="M281" display="inline"><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>w</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mi>h</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>) and of spectra of sonic temperature (<inline-formula><mml:math id="M282" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula>) and <inline-formula><mml:math id="M283" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratio (<inline-formula><mml:math id="M284" display="inline"><mml:mi>c</mml:mi></mml:math></inline-formula>) or <inline-formula><mml:math id="M285" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> mixing ratio (<inline-formula><mml:math id="M286" display="inline"><mml:mi>h</mml:mi></mml:math></inline-formula>) are shown in Figs. <xref ref-type="fig" rid="FB1"/>–<xref ref-type="fig" rid="FB4"/>. For illustration purposes, the median (RH and) WS class is selected for each site. The (co-)spectra presented have already been filtered so that only best-quality data remain. They are then used to compute TFs and cofs. For spectra only, it should be noted that an additional step of noise removal, if needed, is performed on the presented data before the cof computation.</p><fig id="FB1"><label>Figure B1</label><caption><p id="d2e5427">Average normalised co-spectra of sensible heat (wT, red) and <inline-formula><mml:math id="M287" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux (wc, blue). co-spectra are normalised by their respective covariances. For each site, data from the median WS class is used and the mean WS value of that class shown. The co-spectra shown have been filtered using the quality thresholds defined for the cof computation, and they represent the data directly used to derive the TF and subsequently the cof. In practice, this filtering retains only high-quality data characterised by strong turbulent fluxes. The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f11.png"/>

      </fig>

<fig id="FB2"><label>Figure B2</label><caption><p id="d2e5453">Average normalised spectra of sonic temperature (<inline-formula><mml:math id="M288" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula>, red) and <inline-formula><mml:math id="M289" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> mixing ratio (<inline-formula><mml:math id="M290" display="inline"><mml:mi>c</mml:mi></mml:math></inline-formula>, blue). Spectra are normalised by their respective variances. For each site, data from the median wind speed class is    used and the mean value of that class shown. The spectra shown have been filtered using the quality thresholds defined for the cof computation, and they represent the data used to derive the TF and subsequently the cof. In practice, this filtering retains only high-quality data characterised by strong turbulent fluxes. The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f12.png"/>

      </fig>

<fig id="FB3"><label>Figure B3</label><caption><p id="d2e5492">Same as Fig. <xref ref-type="fig" rid="FB1"/>, but for <inline-formula><mml:math id="M291" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>. The median RH class is selected, in addition to the median WS class.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f13.png"/>

      </fig>

<fig id="FB4"><label>Figure B4</label><caption><p id="d2e5521">Same as Fig. <xref ref-type="fig" rid="FB2"/>, but for <inline-formula><mml:math id="M292" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>. The median RH class is selected, in addition to the median WS class.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f14.png"/>

      </fig>


</app>

<app id="App1.Ch1.S3">
  <label>Appendix C</label><title>Cumulated fluxes</title>
      <p id="d2e5557">The yearly cumulative fluxes for <inline-formula><mml:math id="M293" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M294" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> are presented in Figs. <xref ref-type="fig" rid="FC1"/> and <xref ref-type="fig" rid="FC2"/>. The half-hourly fluxes used for the cumulative flux computation were filtered for poor quality and low atmospheric turbulence and filtered time series were not gap-filled to avoid additional complexity. Therefore, the cumulative values are not intended to represent the true yearly exchange, but relative differences between methods are supposed to be representative. The mean data coverage after filtering was 39 % for both <inline-formula><mml:math id="M295" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M296" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>. It should be noted that for water fluxes, as half-hours with low <inline-formula><mml:math id="M297" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mainly include night-time periods during which fluxes are generally very small, their addition would not change much the overall budget, so that the presented cumulative value can be considered as a fairly good estimate of the true <italic>LE</italic> budget over the year.</p>

      <fig id="FC1"><label>Figure C1</label><caption><p id="d2e5629"><inline-formula><mml:math id="M298" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> cumulative fluxes for quality and <inline-formula><mml:math id="M299" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> filtered data only. Uncorrected fluxes, spectra-, co-spectra- and ICOS-corrected fluxes are shown. <inline-formula><mml:math id="M300" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> is the number of half-hours used. The storage term is not    included (only turbulent data is used). The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f15.png"/>

      </fig>

<fig id="FC2"><label>Figure C2</label><caption><p id="d2e5672"><italic>LE</italic> cumulative fluxes for quality and <inline-formula><mml:math id="M301" display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> filtered data. Uncorrected fluxes, spectra-, co-spectra- and ICOS-corrected fluxes are shown. <inline-formula><mml:math id="M302" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> is the number of half-hours used. The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f16.png"/>

      </fig>


</app>

<app id="App1.Ch1.S4">
  <label>Appendix D</label><title>H<sub>2</sub>O correction dependence on relative humidity</title>
      <p id="d2e5723">The spectral analysis and correction procedure was built to account for the known dependence of water spectral losses to RH. Therefore, each site's full dataset is divided into RH classes prior to both cof and CF computation. The results of such classification are investigated. The cof is expected to decrease with  RH following an exponential decay, which is found to be the case for all sites (Fig. <xref ref-type="fig" rid="FD1"/>). The cof–RH dependence has a direct consequence on the CF computation, which is found to be driven by both WS and RH (Figs. <xref ref-type="fig" rid="FD2"/> and <xref ref-type="fig" rid="FD3"/>).</p>

      <fig id="FD1"><label>Figure D1</label><caption><p id="d2e5734">Fit of exponential equation to the average cof values per RH class The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f17.png"/>

      </fig>

<fig id="FD2"><label>Figure D2</label><caption><p id="d2e5749">Spectral and co-spectral <inline-formula><mml:math id="M304" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> CF as a function of wind speed, as shown in Fig. <xref ref-type="fig" rid="F8"/> but for all relative humidity conditions. The additional dependence on RH is found in the larger data spread (shaded area around the lines corresponding to <inline-formula><mml:math id="M305" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> SD around the mean). The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f18.png"/>

      </fig>

<fig id="FD3"><label>Figure D3</label><caption><p id="d2e5788">Dependence of <inline-formula><mml:math id="M306" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula> CF on wind speed and relative humidity classes for unstable conditions only. The RH are built as constant-point classes based on the available data, and they are therefore slightly    different for each site. The spectral results (triangles) are fully experimental CF, prior to the inclusion of the sensor separation term. The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f19.png"/>

      </fig>


</app>

<app id="App1.Ch1.S5">
  <label>Appendix E</label><title>Theoretical dependencies of the sensor separation correction factor</title>
      <p id="d2e5822">The experimental part of the spectral correction approach does not include the attenuation from the sensor separation effect, which therefore has to be accounted for with an additional theoretical term (Eq. <xref ref-type="disp-formula" rid="Ch1.E6"/>). In this work, the sensor separation CF defined by <xref ref-type="bibr" rid="bib1.bibx15" id="text.85"/> is used (Eqs. 16 and 28, corresponding to the cross-wind and vertical separation effects respectively). Their method uses an exponential model to estimate the attenuation as a function of co-spectral peak frequency (parametrised according to stability) and the distance between the sensors (depending on wind direction). The shapes of these relationships and the corresponding CF orders of magnitude are shown for artificial data in Fig. <xref ref-type="fig" rid="FE1"/>, and will be tested against experimental data.</p>

      <fig id="FE1"><label>Figure E1</label><caption><p id="d2e5834">Analytical dependencies of sensor separation correction factor according to <xref ref-type="bibr" rid="bib1.bibx15" id="text.86"/>. Cross-separation wind direction (90° in the figure) yields the maximum distance between the sensors and thus the maximum CF <bold>(a)</bold>. The CF is highly sensitive to    stability for <inline-formula><mml:math id="M307" display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi>z</mml:mi><mml:mi>L</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula> <inline-formula><mml:math id="M308" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 0 <bold>(b)</bold>. A strong dependence on horizontal <bold>(c)</bold> and vertical <bold>(d)</bold> distances between the sensors is expected. Finally, sites measuring closer to the canopy are linked to higher CFs.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f20.png"/>

      </fig>

<fig id="FE2"><label>Figure E2</label><caption><p id="d2e5883">Contribution of sensor separation term to overall correction factor, for both <inline-formula><mml:math id="M309" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M310" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:math></inline-formula>, by stability condition. The percentage change is computed as <inline-formula><mml:math id="M311" display="inline"><mml:mrow><mml:mn mathvariant="normal">100</mml:mn><mml:mo>×</mml:mo><mml:mo>(</mml:mo><mml:msub><mml:mtext>CF</mml:mtext><mml:mtext>HL09</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>)</mml:mo><mml:mo>/</mml:mo><mml:mo>(</mml:mo><mml:mtext>CF</mml:mtext><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Box frame <inline-formula><mml:math id="M312" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 25–75 % interquartile range (IQR), bold line <inline-formula><mml:math id="M313" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> median, whiskers <inline-formula><mml:math id="M314" display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> 1.5 <inline-formula><mml:math id="M315" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> IQR. The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f21.png"/>

      </fig>

<fig id="FE3"><label>Figure E3</label><caption><p id="d2e5986"><inline-formula><mml:math id="M316" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> co-spectral and spectral correction factors as a function of wind direction, grouped in equal-number-of-points bins. Data is filtered for unstable conditions. The direction effect of wind speed is visible on the dependence of the CFs on WD. The red bold titles represent the low-measurement-height sites.</p></caption>
        
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6037/2026/amt-19-6037-2026-f22.png"/>

      </fig>


</app>

<app id="App1.Ch1.S6">
  <label>Appendix F</label><title>Flux-tower stations used</title>

<table-wrap id="TF1"><label>Table F1</label><caption><p id="d2e6021">Site and set-up characteristics.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Station</oasis:entry>
         <oasis:entry colname="col2">Latitude</oasis:entry>
         <oasis:entry colname="col3">Longitude</oasis:entry>
         <oasis:entry colname="col4">PFT</oasis:entry>
         <oasis:entry colname="col5">EC <inline-formula><mml:math id="M320" display="inline"><mml:mi>h</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6">can. <inline-formula><mml:math id="M321" display="inline"><mml:mi>h</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7">Flow rate</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4"/>
         <oasis:entry colname="col5">(m)</oasis:entry>
         <oasis:entry colname="col6">(m)</oasis:entry>
         <oasis:entry colname="col7">(<inline-formula><mml:math id="M322" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">BE-Bra</oasis:entry>
         <oasis:entry colname="col2">51.30761</oasis:entry>
         <oasis:entry colname="col3">4.51984</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">32.6</oasis:entry>
         <oasis:entry colname="col6">22.0</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">BE-Dor</oasis:entry>
         <oasis:entry colname="col2">50.31188</oasis:entry>
         <oasis:entry colname="col3">4.96811</oasis:entry>
         <oasis:entry colname="col4">GRA</oasis:entry>
         <oasis:entry colname="col5">2.0</oasis:entry>
         <oasis:entry colname="col6">0.2</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">BE-Lon</oasis:entry>
         <oasis:entry colname="col2">50.55162</oasis:entry>
         <oasis:entry colname="col3">4.74623</oasis:entry>
         <oasis:entry colname="col4">CRO</oasis:entry>
         <oasis:entry colname="col5">2.0</oasis:entry>
         <oasis:entry colname="col6">0.3</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">BE-Maa</oasis:entry>
         <oasis:entry colname="col2">50.97987</oasis:entry>
         <oasis:entry colname="col3">5.63185</oasis:entry>
         <oasis:entry colname="col4">CSH</oasis:entry>
         <oasis:entry colname="col5">3.0</oasis:entry>
         <oasis:entry colname="col6">1.1</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">BE-Vie</oasis:entry>
         <oasis:entry colname="col2">50.30496</oasis:entry>
         <oasis:entry colname="col3">5.99810</oasis:entry>
         <oasis:entry colname="col4">MF</oasis:entry>
         <oasis:entry colname="col5">51.0</oasis:entry>
         <oasis:entry colname="col6">29.0</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CH-Dav</oasis:entry>
         <oasis:entry colname="col2">46.81533</oasis:entry>
         <oasis:entry colname="col3">9.85591</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">35.0</oasis:entry>
         <oasis:entry colname="col6">19.2</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CZ-BK1</oasis:entry>
         <oasis:entry colname="col2">49.50208</oasis:entry>
         <oasis:entry colname="col3">18.53688</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">25.0</oasis:entry>
         <oasis:entry colname="col6">17.2</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CZ-Lnz</oasis:entry>
         <oasis:entry colname="col2">48.68155</oasis:entry>
         <oasis:entry colname="col3">16.94633</oasis:entry>
         <oasis:entry colname="col4">DBF</oasis:entry>
         <oasis:entry colname="col5">44.0</oasis:entry>
         <oasis:entry colname="col6">27.0</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">DE-Geb</oasis:entry>
         <oasis:entry colname="col2">51.09973</oasis:entry>
         <oasis:entry colname="col3">10.91463</oasis:entry>
         <oasis:entry colname="col4">CRO</oasis:entry>
         <oasis:entry colname="col5">3.0</oasis:entry>
         <oasis:entry colname="col6">0.5</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">DE-HoH</oasis:entry>
         <oasis:entry colname="col2">52.08656</oasis:entry>
         <oasis:entry colname="col3">11.22235</oasis:entry>
         <oasis:entry colname="col4">DBF</oasis:entry>
         <oasis:entry colname="col5">45.0</oasis:entry>
         <oasis:entry colname="col6">29.5</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">DE-RuS</oasis:entry>
         <oasis:entry colname="col2">50.86591</oasis:entry>
         <oasis:entry colname="col3">6.44714</oasis:entry>
         <oasis:entry colname="col4">CRO</oasis:entry>
         <oasis:entry colname="col5">2.7</oasis:entry>
         <oasis:entry colname="col6">0.4</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">DE-Tha</oasis:entry>
         <oasis:entry colname="col2">50.96256</oasis:entry>
         <oasis:entry colname="col3">13.56515</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">42.0</oasis:entry>
         <oasis:entry colname="col6">30.6</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">DK-Sor</oasis:entry>
         <oasis:entry colname="col2">55.48587</oasis:entry>
         <oasis:entry colname="col3">11.64464</oasis:entry>
         <oasis:entry colname="col4">DBF</oasis:entry>
         <oasis:entry colname="col5">43.6</oasis:entry>
         <oasis:entry colname="col6">23.5</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FI-Hyy</oasis:entry>
         <oasis:entry colname="col2">61.84741</oasis:entry>
         <oasis:entry colname="col3">24.29477</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">27.0</oasis:entry>
         <oasis:entry colname="col6">21.4</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FI-Sii</oasis:entry>
         <oasis:entry colname="col2">61.83265</oasis:entry>
         <oasis:entry colname="col3">24.19285</oasis:entry>
         <oasis:entry colname="col4">WET</oasis:entry>
         <oasis:entry colname="col5">3.0</oasis:entry>
         <oasis:entry colname="col6">0.2</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FI-Sod</oasis:entry>
         <oasis:entry colname="col2">67.36239</oasis:entry>
         <oasis:entry colname="col3">26.63859</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">25.1</oasis:entry>
         <oasis:entry colname="col6">12.4</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-Bil</oasis:entry>
         <oasis:entry colname="col2">44.49365</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M323" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.95609</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">15.6</oasis:entry>
         <oasis:entry colname="col6">9.5</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-FBn</oasis:entry>
         <oasis:entry colname="col2">43.24079</oasis:entry>
         <oasis:entry colname="col3">5.67865</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">17.4</oasis:entry>
         <oasis:entry colname="col6">8.4</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-Fon</oasis:entry>
         <oasis:entry colname="col2">48.47636</oasis:entry>
         <oasis:entry colname="col3">2.78010</oasis:entry>
         <oasis:entry colname="col4">DBF</oasis:entry>
         <oasis:entry colname="col5">37.0</oasis:entry>
         <oasis:entry colname="col6">22.2</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-Gri</oasis:entry>
         <oasis:entry colname="col2">48.84422</oasis:entry>
         <oasis:entry colname="col3">1.95191</oasis:entry>
         <oasis:entry colname="col4">CRO</oasis:entry>
         <oasis:entry colname="col5">2.0</oasis:entry>
         <oasis:entry colname="col6">0.3</oasis:entry>
         <oasis:entry colname="col7">15.0/12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-Hes</oasis:entry>
         <oasis:entry colname="col2">48.67410</oasis:entry>
         <oasis:entry colname="col3">7.06465</oasis:entry>
         <oasis:entry colname="col4">DBF</oasis:entry>
         <oasis:entry colname="col5">30.0</oasis:entry>
         <oasis:entry colname="col6">16.4</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-Lqu</oasis:entry>
         <oasis:entry colname="col2">45.64440</oasis:entry>
         <oasis:entry colname="col3">2.73490</oasis:entry>
         <oasis:entry colname="col4">GRA</oasis:entry>
         <oasis:entry colname="col5">2.0</oasis:entry>
         <oasis:entry colname="col6">0.1</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-Lus</oasis:entry>
         <oasis:entry colname="col2">46.41425</oasis:entry>
         <oasis:entry colname="col3">0.12065</oasis:entry>
         <oasis:entry colname="col4">GRA</oasis:entry>
         <oasis:entry colname="col5">2.0</oasis:entry>
         <oasis:entry colname="col6">0.2</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">FR-Pue</oasis:entry>
         <oasis:entry colname="col2">43.74130</oasis:entry>
         <oasis:entry colname="col3">3.59570</oasis:entry>
         <oasis:entry colname="col4">EBF</oasis:entry>
         <oasis:entry colname="col5">12.0</oasis:entry>
         <oasis:entry colname="col6">5.2</oasis:entry>
         <oasis:entry colname="col7">12.5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">GL-ZaF</oasis:entry>
         <oasis:entry colname="col2">74.48152</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M324" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>20.55577</oasis:entry>
         <oasis:entry colname="col4">WET</oasis:entry>
         <oasis:entry colname="col5">3.2</oasis:entry>
         <oasis:entry colname="col6">0.2</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IT-BCi</oasis:entry>
         <oasis:entry colname="col2">40.52375</oasis:entry>
         <oasis:entry colname="col3">14.95744</oasis:entry>
         <oasis:entry colname="col4">CRO</oasis:entry>
         <oasis:entry colname="col5">2.1</oasis:entry>
         <oasis:entry colname="col6">0.8</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IT-Cp2</oasis:entry>
         <oasis:entry colname="col2">41.70427</oasis:entry>
         <oasis:entry colname="col3">12.35729</oasis:entry>
         <oasis:entry colname="col4">MF</oasis:entry>
         <oasis:entry colname="col5">20.9</oasis:entry>
         <oasis:entry colname="col6">13.8</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IT-MBo</oasis:entry>
         <oasis:entry colname="col2">46.01468</oasis:entry>
         <oasis:entry colname="col3">11.04583</oasis:entry>
         <oasis:entry colname="col4">GRA</oasis:entry>
         <oasis:entry colname="col5">2.4</oasis:entry>
         <oasis:entry colname="col6">0.1</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IT-Ren</oasis:entry>
         <oasis:entry colname="col2">46.58686</oasis:entry>
         <oasis:entry colname="col3">11.43369</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">33.7</oasis:entry>
         <oasis:entry colname="col6">15.1</oasis:entry>
         <oasis:entry colname="col7">15.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">IT-SR2</oasis:entry>
         <oasis:entry colname="col2">43.73202</oasis:entry>
         <oasis:entry colname="col3">10.29091</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">24.3</oasis:entry>
         <oasis:entry colname="col6">20.3</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">NL-Loo</oasis:entry>
         <oasis:entry colname="col2">52.16645</oasis:entry>
         <oasis:entry colname="col3">5.74355</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">38.2</oasis:entry>
         <oasis:entry colname="col6">16.4</oasis:entry>
         <oasis:entry colname="col7">10.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">NO-Hur</oasis:entry>
         <oasis:entry colname="col2">60.37163</oasis:entry>
         <oasis:entry colname="col3">11.07949</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">42.0</oasis:entry>
         <oasis:entry colname="col6">17.6</oasis:entry>
         <oasis:entry colname="col7">16.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SE-Deg</oasis:entry>
         <oasis:entry colname="col2">64.18203</oasis:entry>
         <oasis:entry colname="col3">19.55654</oasis:entry>
         <oasis:entry colname="col4">WET</oasis:entry>
         <oasis:entry colname="col5">3.0</oasis:entry>
         <oasis:entry colname="col6">0.4</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SE-Htm</oasis:entry>
         <oasis:entry colname="col2">56.09763</oasis:entry>
         <oasis:entry colname="col3">13.41897</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">27.0</oasis:entry>
         <oasis:entry colname="col6">19.3</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SE-Nor</oasis:entry>
         <oasis:entry colname="col2">60.08650</oasis:entry>
         <oasis:entry colname="col3">17.47950</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">36.0</oasis:entry>
         <oasis:entry colname="col6">26.3</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SE-Sto</oasis:entry>
         <oasis:entry colname="col2">68.35594</oasis:entry>
         <oasis:entry colname="col3">19.04521</oasis:entry>
         <oasis:entry colname="col4">WET</oasis:entry>
         <oasis:entry colname="col5">2.2</oasis:entry>
         <oasis:entry colname="col6">0.3</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">SE-Svb</oasis:entry>
         <oasis:entry colname="col2">64.25611</oasis:entry>
         <oasis:entry colname="col3">19.77450</oasis:entry>
         <oasis:entry colname="col4">ENF</oasis:entry>
         <oasis:entry colname="col5">34.5</oasis:entry>
         <oasis:entry colname="col6">14.7</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">UK-AMo</oasis:entry>
         <oasis:entry colname="col2">55.79255</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M325" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>3.24369</oasis:entry>
         <oasis:entry colname="col4">WET</oasis:entry>
         <oasis:entry colname="col5">4.0</oasis:entry>
         <oasis:entry colname="col6">0.6</oasis:entry>
         <oasis:entry colname="col7">12.0</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d2e6024"> Note: in addition to station official ID, coordinates are reported, together with plant functional type (PFT), height of the eddy covariance system (EC <inline-formula><mml:math id="M317" display="inline"><mml:mi>h</mml:mi></mml:math></inline-formula>, m), mean canopy height (can <inline-formula><mml:math id="M318" display="inline"><mml:mi>h</mml:mi></mml:math></inline-formula>, m), and flow rate of the gas sampling system (<inline-formula><mml:math id="M319" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">L</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">min</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). PFT acronyms: CRO, Croplands; CSH, Closed Shrublands; DBF, Deciduous Broadleaf Forests; EBF, Evergreen Broadleaf Forests; ENF, Evergreen Needleleaf Forests; GRA, Grasslands; MF, Mixed Forests; WET, Permanent Wetlands.</p></table-wrap-foot></table-wrap>

</app>
  </app-group><notes notes-type="codeavailability"><title>Code availability</title>

      <p id="d2e7138">FreqCor v1.3, the python tool used in this paper to compare cospectral and spectral corrections, starting from (co-)spectra, is openly available on Zenodo (<ext-link xlink:href="https://doi.org/10.5281/zenodo.22877082" ext-link-type="DOI">10.5281/zenodo.22877082</ext-link>, <xref ref-type="bibr" rid="bib1.bibx9" id="altparen.87"/>). Further versions of the tool can also be found on the associated GitHub project.</p>
  </notes><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d2e7150">EddyPro ensemble (co-)spectra and full output file for all ICOS Class 1 and 2 stations used in this study can be obtained on request from the ICOS Ecosystem Thematic Centre. Alternatively, they can be computed from the site-level <inline-formula><mml:math id="M326" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> Hz raw data available through the ICOS Carbon Portal (<uri>https://www.icos-cp.eu</uri>, last access: 22 September 2026), using EddyPro version 7.0.9 and the corresponding configuration files, which can also be obtained on request from the ICOS Ecosystem Thematic Centre.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d2e7171">This study was conceptualized by BH and AF. AF performed the formal analysis and visualization of the final datasets and wrote the first draft of the manuscript. GN, SS, and DP provided access to, and support in acquiring, ICOS intermediate data that were not available through the Carbon Portal. All authors participated in reviewing the last version of the manuscript, that was finalized by BH. BH also contributed to funding acquisition and supervised the research activities.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d2e7177">The contact author has declared that none of the authors has any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d2e7183">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. The authors bear the ultimate responsibility for providing appropriate place names. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.</p>
  </notes><ack><title>Acknowledgements</title><p id="d2e7189">The authors thank Marc Aubinet for initiating this methodological discussion several years ago, as well as all the staff involved in maintaining the ICOS flux tower stations used in this study.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d2e7194">This research has been supported by the Service Public de Wallonie (Public Service of Wallonia) (grant-no. 1217769).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d2e7200">This paper was edited by Luca Mortarini and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Asanuma et al.(2007)Asanuma, Tamagawa, Ishikawa, Ma, Hayashi, Qi, and Wang</label><mixed-citation>Asanuma, J., Tamagawa, I., Ishikawa, H., Ma, Y., Hayashi, T., Qi, Y., and Wang, J.: Spectral similarity between scalars at very low frequencies in the unstable atmospheric surface layer over the Tibetan plateau, Bound.-Lay. Meteorol., 122, 85–103, <ext-link xlink:href="https://doi.org/10.1007/s10546-006-9096-y" ext-link-type="DOI">10.1007/s10546-006-9096-y</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Aslan et al.(2021)Aslan, Peltola, Ibrom, Nemitz, Rannik, and Mammarella</label><mixed-citation>Aslan, T., Peltola, O., Ibrom, A., Nemitz, E., Rannik, Ü., and Mammarella, I.: The high-frequency response correction of eddy covariance fluxes – Part 2: An experimental approach for analysing noisy measurements of small fluxes, Atmos. Meas. Tech., 14, 5089–5106, <ext-link xlink:href="https://doi.org/10.5194/amt-14-5089-2021" ext-link-type="DOI">10.5194/amt-14-5089-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Aubinet et al.(2000)Aubinet, Grelle, Ibrom, Rannik, Moncrieff, Foken, Kowalski, Martin, Berbigier, Bernhofer, Clement, Elbers, Granier, Grünwald, Morgenstern, Pilegaard, Rebmann, Snijders, Valentini, and Vesala</label><mixed-citation>Aubinet, M., Grelle, A., Ibrom, A., Rannik, Ü., Moncrieff, J., Foken, T., Kowalski, A., Martin, P., Berbigier, P., Bernhofer, C., Clement, R., Elbers, J., Granier, A., Grünwald, T., Morgenstern, K., Pilegaard, K., Rebmann, C., Snijders, W., Valentini, R., and Vesala, T.: Estimates of the Annual Net Carbon and Water Exchange of Forests: The EUROFLUX Methodology, in: Advances in Ecological Research, Vol. 30, Elsevier, 113–175, <ext-link xlink:href="https://doi.org/10.1016/S0065-2504(08)60018-5" ext-link-type="DOI">10.1016/S0065-2504(08)60018-5</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Aubinet et al.(2012)Aubinet, Vesala, and Papale</label><mixed-citation>Aubinet, M., Vesala, T., and Papale, D., (Eds.): Eddy Covariance: A Practical Guide to Measurement and Data Analysis, Springer Netherlands, Dordrecht, <ext-link xlink:href="https://doi.org/10.1007/978-94-007-2351-1" ext-link-type="DOI">10.1007/978-94-007-2351-1</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Baldocchi(2014)</label><mixed-citation>Baldocchi, D.: Measuring fluxes of trace gases and energy between ecosystems and the atmosphere – the state and future of the eddy covariance method, Glob. Change Biol., 20, 3600–3609, <ext-link xlink:href="https://doi.org/10.1111/gcb.12649" ext-link-type="DOI">10.1111/gcb.12649</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>De Ligne et al.(2010)De Ligne, Heinesch, and Aubinet</label><mixed-citation>De Ligne, A., Heinesch, B., and Aubinet, M.: New Transfer Functions for Correcting Turbulent Water Vapour Fluxes, Bound.-Lay. Meteorol., 137, 205–221, <ext-link xlink:href="https://doi.org/10.1007/s10546-010-9525-9" ext-link-type="DOI">10.1007/s10546-010-9525-9</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Emad(2023)</label><mixed-citation>Emad, A.: Optimal Frequency-Response Corrections for Eddy Covariance Flux Measurements Using the Wiener Deconvolution Method, Bound.-Lay. Meteorol., <ext-link xlink:href="https://doi.org/10.1007/s10546-023-00799-w" ext-link-type="DOI">10.1007/s10546-023-00799-w</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Eugster and Senn(1995)</label><mixed-citation>Eugster, W. and Senn, W.: A cospectral correction model for measurement of turbulent <inline-formula><mml:math id="M327" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> flux, Bound.-Lay. Meteorol., 74, 321–340, <ext-link xlink:href="https://doi.org/10.1007/BF00712375" ext-link-type="DOI">10.1007/BF00712375</ext-link>, 1995.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Faurès and  Heinesch(2026)</label><mixed-citation>Faurès, A. and  Heinesch, B.: FreqCor (Version v1.3),  Zenodo [code], <ext-link xlink:href="https://doi.org/10.5281/zenodo.22877082" ext-link-type="DOI">10.5281/zenodo.22877082</ext-link>, 2026.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Foken et al.(2012a)Foken, Aubinet, and Leuning</label><mixed-citation>Foken, T., Aubinet, M., and Leuning, R.: The Eddy Covariance Method, in: Eddy Covariance – A Practical Guide to Measurement and Data Analysis, edited by: Aubinet, M., Vesala, T., and Papale, D., Springer Netherlands, Dordrecht, <ext-link xlink:href="https://doi.org/10.1007/978-94-007-2351-1_1" ext-link-type="DOI">10.1007/978-94-007-2351-1_1</ext-link>, 2012a.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Foken et al.(2012b)Foken, Leuning, Oncley, Mauder, and Aubinet</label><mixed-citation>Foken, T., Leuning, R., Oncley, S. R., Mauder, M., and Aubinet, M.: Corrections and Data Quality Control, in: Eddy Covariance – A Practical Guide to Measurement and Data Analysis, edited by: Aubinet, M., Vesala, T., and Papale, D., Springer Netherlands, Dordrecht, <ext-link xlink:href="https://doi.org/10.1007/978-94-007-2351-1_4" ext-link-type="DOI">10.1007/978-94-007-2351-1_4</ext-link>, 2012b.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Franz et al.(2018)Franz, Acosta, Altimir, Arriga, Arrouays, Aubinet, Aurela, Ayres, López-Ballesteros, Barbaste, Berveiller, Biraud, Boukir, Brown, Brömmer, Buchmann, Burba, Carrara, Cescatti, Ceschia, Clement, Cremonese, Crill, Darenova, Dengel, D'Odorico, Filippa, Fleck, Fratini, Fuß, Gielen, Gogo, Grace, Graf, Grelle, Gross, Grönwald, Haapanala, Hehn, Heinesch, Heiskanen, Herbst, Herschlein, Hörtnagl, Hufkens, Ibrom, Jolivet, Joly, Jones, Kiese, Klemedtsson, Kljun, Klumpp, Kolari, Kolle, Kowalski, Kutsch, Laurila, Ligne, Linder, Lindroth, Lohila, Longdoz, Mammarella, Manise, Jiménez, Matteucci, Mauder, Meier, Merbold, Mereu, Metzger, Migliavacca, Mölder, Montagnani, Moureaux, Nelson, Nemitz, Nicolini, Nilsson, Beeck, Osborne, Löfvenius, Pavelka, Peichl, Peltola, Pihlatie, Pitacco, Pokorný, Pumpanen, Ratié, Rebmann, Roland, Sabbatini, Saby, Saunders, Schmid, Schrumpf, Sedlák, Ortiz, Siebicke, Šigut, Silvennoinen, Simioni, Skiba, Sonnentag, Soudani, Soulé, Steinbrecher, Tallec, Thimonier, Tuittila, Tuovinen, Vestin, Vincent, Vincke, Vitale, Waldner, Weslien, Wingate, Wohlfahrt, Zahniser, and Vesala</label><mixed-citation>Franz, D., Acosta, M., Altimir, N., Arriga, N., Arrouays, D., Aubinet, M., Aurela, M., Ayres, E., López-Ballesteros, A., Barbaste, M., Berveiller, D., Biraud, S., Boukir, H., Brown, T., Brömmer, C., Buchmann, N., Burba, G., Carrara, A., Cescatti, A., Ceschia, E., Clement, R., Cremonese, E., Crill, P., Darenova, E., Dengel, S., D'Odorico, P., Filippa, G., Fleck, S., Fratini, G., Fuß, R., Gielen, B., Gogo, S., Grace, J., Graf, A., Grelle, A., Gross, P., Grönwald, T., Haapanala, S., Hehn, M., Heinesch, B., Heiskanen, J., Herbst, M., Herschlein, C., Hörtnagl, L., Hufkens, K., Ibrom, A., Jolivet, C., Joly, L., Jones, M., Kiese, R., Klemedtsson, L., Kljun, N., Klumpp, K., Kolari, P., Kolle, O., Kowalski, A., Kutsch, W., Laurila, T., Ligne, A. D., Linder, S., Lindroth, A., Lohila, A., Longdoz, B., Mammarella, I., Manise, T., Jiménez, S. M., Matteucci, G., Mauder, M., Meier, P., Merbold, L., Mereu, S., Metzger, S., Migliavacca, M., Mölder, M., Montagnani, L., Moureaux, C., Nelson, D., Nemitz, E., Nicolini, G., Nilsson, M. B., Beeck, M. O. M. D., Osborne, B., Löfvenius, M. O., Pavelka, M., Peichl, M., Peltola, O., Pihlatie, M., Pitacco, A., Pokorný, R., Pumpanen, J., Ratié, C., Rebmann, C., Roland, M., Sabbatini, S., Saby, N. P. A., Saunders, M., Schmid, H. P., Schrumpf, M., Sedlák, P., Ortiz, P. S., Siebicke, L., Šigut, L., Silvennoinen, H., Simioni, G., Skiba, U., Sonnentag, O., Soudani, K., Soulé, P., Steinbrecher, R., Tallec, T., Thimonier, A., Tuittila, E.-S., Tuovinen, J.-P., Vestin, P., Vincent, G., Vincke, C., Vitale, D., Waldner, P., Weslien, P., Wingate, L., Wohlfahrt, G., Zahniser, M., and Vesala, T.: Towards long-Term standardised carbon and greenhouse gas observations for monitoring Europe's terrestrial ecosystems: A review, Int. Agrophys., 32, 439–455, <ext-link xlink:href="https://doi.org/10.1515/intag-2017-0039" ext-link-type="DOI">10.1515/intag-2017-0039</ext-link>, cited By 2, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Fratini et al.(2012)Fratini, Ibrom, Arriga, Burba, and Papale</label><mixed-citation>Fratini, G., Ibrom, A., Arriga, N., Burba, G., and Papale, D.: Relative humidity effects on water vapour fluxes measured with closed-path eddy-covariance systems with short sampling lines, Agr. Forest Meteorol., 165, 53–63, <ext-link xlink:href="https://doi.org/10.1016/j.agrformet.2012.05.018" ext-link-type="DOI">10.1016/j.agrformet.2012.05.018</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Horst(1997)</label><mixed-citation>Horst, T. W.: A simple formula for attenuation of Eddy fluxes measured with first-order-response scalar sensors, Bound.-Lay. Meteorol., 82, 219–233, <ext-link xlink:href="https://doi.org/10.1023/A:1000229130034" ext-link-type="DOI">10.1023/A:1000229130034</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Horst and Lenschow(2009)</label><mixed-citation>Horst, T. W. and Lenschow, D. H.: Attenuation of Scalar Fluxes Measured with Spatially-displaced Sensors, Bound.-Lay. Meteorol., 130, 275–300, <ext-link xlink:href="https://doi.org/10.1007/s10546-008-9348-0" ext-link-type="DOI">10.1007/s10546-008-9348-0</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Hunt et al.(2016)Hunt, Laubach, Barthel, Fraser, and Phillips</label><mixed-citation>Hunt, J. E., Laubach, J., Barthel, M., Fraser, A., and Phillips, R. L.: Carbon budgets for an irrigated intensively grazed dairy pasture and an unirrigated winter-grazed pasture, Biogeosciences, 13, 2927–2944, <ext-link xlink:href="https://doi.org/10.5194/bg-13-2927-2016" ext-link-type="DOI">10.5194/bg-13-2927-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Ibrom et al.(2007)Ibrom, Dellwik, Flyvbjerg, Jensen, and Pilegaard</label><mixed-citation>Ibrom, A., Dellwik, E., Flyvbjerg, H., Jensen, N. O., and Pilegaard, K.: Strong low-pass filtering effects on water vapour flux measurements with closed-path eddy correlation systems, Agr. Forest Meteorol., 147, 140–156, <ext-link xlink:href="https://doi.org/10.1016/j.agrformet.2007.07.007" ext-link-type="DOI">10.1016/j.agrformet.2007.07.007</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>ICOS RI et al.(2025)</label><mixed-citation>ICOS RI, Aalto, J., Aalto, P., Aaltonen, H., Aiguier, T., Akubia, J.,  Ala-Könni, J., Alivernini, A., Alonso, L., Aluome, C., Andersson, T., Arriga, N., Aurela, M., BRECHET, L., Baab, F., Back, J., Bagheri, S., Baltes, U., Baneschi, I., Barral, H., Barten, S., Bastos Campos, F., Baur, T., Bauters, M., Bazot, S., Beauclair, P., Becker, N., Behrens, N., Belelli Marchesini, L., Bergström, G., Bernhofer, C., Berveiller, D., Biermann, T., Bignotti, L., Biron, R., Bloor, J., Bodson, B., Boeckx, P., Boeske, L., Bogaerts, G., Bonal, D., Boon, G., Bornet, F., Bortoli, M., Boschetti, F., Bosio, I., Bresseleers, S., Brut, A., Brümmer, C., Buchmann, N., Bulonza, E., Burban, B., Burri, S., Buysse, P., Båth, A., Calandrelli, D., Calvet, J.-C., Canut-Rocafort, G., Carrara, A., Cash, J., Cavagna, M., Ceschia, E., Chabbi, A., Chan, T., Chebbi, W., Chebil, B., Chianucci, F., Chipeaux, C., Chopin, H., Christen, A., Chrysoulakis, N., Claverie, N., Cobbe, I., Cohard, J.-M., Colosse, D., Conte, A., Corsanici, R., Coulaud, C., Courtois, P., Coyle, M., Cremonese, E., Crill, P., Cuntz, M., Cuocolo, D., Czerný, R., DEPUYDT, J., Daelman, R., Darenová, E., Darsonville, O., De Ligne, A., De Meulder, T., De Simon, G., Decau, M.-L., Dejosez, S., Dell'Acqua, A., Delorme, J.-P., Delpierre, N., Demoulin, L., Denou, J.-L., Di Tommasi, P., Dienstbach, L., Dignam, R., Dolfus, D., Domec, J.-C., Douxfils, B., Drösler, M., Drüe, C., Dufrêne, E., Dumont, B., Durand, B., Dusek, J., Eberl, J., Eichelmann, U., Ekili, D., Engelmann, T., Esposito, A., Esser, O., Etienne, J.-C., Etzold, S., Eugster, W., Famulari, D., Fares, S., Faurès, A., Fauvel, Y., Feigenwinter, C., Feigenwinter, I., Feldmann, I., Ferraris, D., Filippa, G., Fincham, W., Finco, A., Fischer, M., Flechard, C., Folino, G., Foltýnová, L., Foret, J., Foulquier, A., François, B., Friborg, T., Galliot, J.-N., Galvagno, M., Garcia Quiros, I., Garrigou, C., Gastal, F., Geilfus, N.-X., Gerosa, G., Gessler, A., Gharun, M., Giamberini, M., Gianelle, D., Gibrin, H., Gimper, S., Gioli, B., Girardin, C., Goded, I., Graf, A., Granouillac, F., Grehan, E., Grenier, M., Grudd, H., Grünwald, T., Guillot, T., Guzman, R., Hamon, Y., Harvey, D., Hatakka, J., Haustein, A., Hautmann, D., Hehn, M., Heinesch, B., Helfter, C., Heliasz, M., Herbst, M., Hildebrandt, A., Holst, J., Holst, T., Holtmann, A., Hortnagl, L., Hug, C., Huguet, C., Häni, M., Ibrom, A., Ilardi, F., Jackowicz-Korczynski, M. A., Jacotot, A., Janssens, I., Jensen, R., Jocher, G., Joetzjer, E., Jones, M., Järvi, L., Kalalian, C., Kempf, J., Kempka, P., Keronen, P., Kettler, M., Kimbesa, F., Kivalov, S., Klatt, J., Klimo, P., Kljun, N., Klumpp, K., Kogxylakis, G., Kolari, P., Kolbe, S., Korkiakoski, M., Korrensalo, A., Kowalska, N., Kozii, N., Krejza, J., Kristoffersson, A., Kruijt, B., Kruszewski, A., Kulmala, L., Kumar, S., Kummer, S., Laakso, H., Lafont, S., Lange, H., Lange Rønn, E., Larmanou, E., Laurila, T., Leeson, S., Lefevre, L., Lehner, I., Lemaire, B., Leonard, J., Levula, J., Levy, P., Liechti, K., Liger, L., Lily, J.-B., Limousin, J.-M., Linderson, M.-L., Lindgren, K., Lo Cascio, M., Lodsgaard Justesen, M., Lofvenius, P., Lohila, A., Longdoz, B., Lootens, R., Loubet, B., Loustau, D., Lucarini, A., Lundin, E., López, R., López-Blanco, E., Magliulo, V., Mammarella, I., Manco, A., Manise, T., Marcolla, B., Marek, M. V., Marklund, P., Marloie, O., Marras, S., Martin, R., Martin Saint Paul, N., Marty, M., Martín, M. P., Marzuoli, R., Matilainen, T., Mattes, J., Matteucci, M., Mauder, M., Maurel, W., Mbifo, J., Meggio, F., Meier, F., Meier, P., Meire, A., Meis, J., Meissner, H., Mensah, C., Meyer, H., Michaud, L., Minerbi, S., Moderow, U., Molder, M., Montagnani, L., Moreno, G., Moretti, V., Morfin, A., Morra di Cella, U., Mullinger, N., Mäkelä, T., Männikkö, M., Männistö, E., Møller, F., Naiken, A., Naseer, M., Nemitz, E., Nezval, O., Nilsson, M., Norkko, J., Ocallaghan, F., Ojala, A., Orgun, A., Ottosson-Löfvenius, M., Ourcival, J.-M., Paasch, S., Paci, A., Pavelka, M., Pavot, L., Peichl, M., Peressotti, A., Perot-Guillaume, C., Perrot, C., Pihlatie, M., Pilegaard, K., Pilkottu, R., Piret, A., Pitacco, A., Plapp, T., Plebani, D., Politakos, K., Prasse, H., Provenzale, A., Pumpanen, J., Putzolu, S., Raco, B., Rainne, J., Rakos, N., Rebmann, C., Redepenning, D., Rinne, J., Rodeghiero, M., Roland, M., Rudd, D., Ryhti, K., Røjle Christensen, T., Sahoo, G., Salze, P., Schaarup Sørensen, J., Schindler, D., Schlaipfer, M., Schmidt, M., Schmidt, P., Schmitt Oehler, M., Schrader, F., Segers, J., Shivhalli Gopal, A., Sibret, T., Siivola, E., Simioni, G., Sirca, C., Smith, P., Snellen, H., Sorgi, T., Soudani, K., Spano, D., Spence, K., Spyridakis, N., Stagakis, S., Staník, K., Staudinger, M., Stecher, M., Stellner, S., Stutz, T., Suopajärvi, S., Sutter, F., Taipale, R., Tallec, T., Tenca, F., Tezza, L., Thimonier Rickenmann, A., Thyrion, T., Tomelleri, E., Trotsiuk, V., Trusina, J., Tuittila, E.-S., Tuovinen, J.-P., Tyssandier, J., Vagnoli, C., Valay, J.-G., Van Damme, F., Van Look, J., Vande Sompele, A., Vandome, E., Varjonen, S., Vendrame, N., Ventura, M., Verbeeck, H., Vesala, T., Vescovo, L., Vincent, G., Vincke, C., Vitale, L., Vivaldo, G., Voisin, D., Vágner, L., Vähä, A., Waldner, P., Wiesen, R., Wilhelm, M., Winck, B., Yeung, K., Zaldei, A., Zampedri, R., Zawilski, B., Zenone, T., Zhao, H., Zhao, J., Zhu, J., Zimmermann, S., Zweifel, R., de Berranger, C., van Dijk, N., van der Molen, M., Šigut, L., and Šlížek, J.: Ecosystem final quality (L2) product in ETC-Archive format – release 2025-1, medium: Arbitrary ZIP archive, ICOS ETC half-hourly product CSV Version Number: 1.0, ICOS ERIC – Carbon Portal [data set], <ext-link xlink:href="https://doi.org/10.18160/S6HM-CP8Q" ext-link-type="DOI">10.18160/S6HM-CP8Q</ext-link>, 2025.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>Kaimal et al.(1972)Kaimal, Wyngaard, Izumi, and Coté</label><mixed-citation>Kaimal, J. C., Wyngaard, J. C., Izumi, Y., and Coté, O. R.: Spectral characteristics of surface-layer turbulence, Q. J. Roy. Meteor. Soc., 98, 563–589, <ext-link xlink:href="https://doi.org/10.1002/qj.49709841707" ext-link-type="DOI">10.1002/qj.49709841707</ext-link>, 1972.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Mamadou et al.(2016)Mamadou, Gourlez de la Motte, De Ligne, Heinesch, and Aubinet</label><mixed-citation>Mamadou, O., Gourlez de la Motte, L., De Ligne, A., Heinesch, B., and Aubinet, M.: Sensitivity of the annual net ecosystem exchange to the cospectral model used for high frequency loss corrections at a grazed grassland site, Agr. Forest Meteorol., 228–229, 360–369, <ext-link xlink:href="https://doi.org/10.1016/j.agrformet.2016.06.008" ext-link-type="DOI">10.1016/j.agrformet.2016.06.008</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Mammarella et al.(2009)Mammarella, Launiainen, Gronholm, Keronen, Pumpanen, Rannik, and Vesala</label><mixed-citation>Mammarella, I., Launiainen, S., Gronholm, T., Keronen, P., Pumpanen, J., Rannik, Ü., and Vesala, T.: Relative Humidity Effect on the High-Frequency Attenuation of Water Vapor Flux Measured by a Closed-Path Eddy Covariance System, <ext-link xlink:href="https://doi.org/10.1175/2009JTECHA1179.1" ext-link-type="DOI">10.1175/2009JTECHA1179.1</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Mammarella et al.(2016)Mammarella, Peltola, Nordbo, Järvi, and Rannik</label><mixed-citation>Mammarella, I., Peltola, O., Nordbo, A., Järvi, L., and Rannik, Ü.: Quantifying the uncertainty of eddy covariance fluxes due to the use of different software packages and combinations of processing steps in two contrasting ecosystems, Atmos. Meas. Tech., 9, 4915–4933, <ext-link xlink:href="https://doi.org/10.5194/amt-9-4915-2016" ext-link-type="DOI">10.5194/amt-9-4915-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Massman(2000)</label><mixed-citation>Massman, W.: A simple method for estimating frequency response corrections for eddy covariance systems, Agr. Forest Meteorol., 104, 185–198, <ext-link xlink:href="https://doi.org/10.1016/S0168-1923(00)00164-7" ext-link-type="DOI">10.1016/S0168-1923(00)00164-7</ext-link>, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx24"><label>Massman and Clement(2005)</label><mixed-citation>Massman, W. and Clement, R.: Uncertainty in Eddy Covariance Flux Estimates Resulting from Spectral Attenuation, in: Handbook of Micrometeorology: A Guide for Surface Flux Measurement and Analysis, edited by: Lee, X., Massman, W., and Law, B., Springer Netherlands, Dordrecht, 67–99, <ext-link xlink:href="https://doi.org/10.1007/1-4020-2265-4_4" ext-link-type="DOI">10.1007/1-4020-2265-4_4</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Mauder et al.(2024)Mauder, Jung, Stoy, Nelson, and Wanner</label><mixed-citation>Mauder, M., Jung, M., Stoy, P., Nelson, J., and Wanner, L.: Energy balance closure at FLUXNET sites revisited, Agr. Forest Meteorol., 358, 110235, <ext-link xlink:href="https://doi.org/10.1016/j.agrformet.2024.110235" ext-link-type="DOI">10.1016/j.agrformet.2024.110235</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Moncrieff et al.(2004)Moncrieff, Clement, Finnigan, and Meyers</label><mixed-citation>Moncrieff, J., Clement, R., Finnigan, J., and Meyers, T.: Averaging, Detrending, and Filtering of Eddy Covariance Time Series, in: Handbook of Micrometeorology: A Guide for Surface Flux Measurement and Analysis, edited by: Lee, X., Massman, W., and Law, B., Springer Netherlands, Dordrecht, 7–31, <ext-link xlink:href="https://doi.org/10.1007/1-4020-2265-4_2" ext-link-type="DOI">10.1007/1-4020-2265-4_2</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Moncrieff et al.(1997)Moncrieff, Massheder, de Bruin, Elbers, Friborg, Heusinkveld, Kabat, Scott, Soegaard, and Verhoef</label><mixed-citation>Moncrieff, J. B., Massheder, J. M., de Bruin, H., Elbers, J., Friborg, T., Heusinkveld, B., Kabat, P., Scott, S., Soegaard, H., and Verhoef, A.: A system to measure surface fluxes of momentum, sensible heat, water vapour and carbon dioxide, J. Hydrol., 188–189, 589–611, <ext-link xlink:href="https://doi.org/10.1016/S0022-1694(96)03194-0" ext-link-type="DOI">10.1016/S0022-1694(96)03194-0</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bibx28"><label>Moore(1986)</label><mixed-citation>Moore, C. J.: Frequency response corrections for eddy correlation systems, Bound.-Lay. Meteorol., 37, 17–35, <ext-link xlink:href="https://doi.org/10.1007/BF00122754" ext-link-type="DOI">10.1007/BF00122754</ext-link>, 1986.</mixed-citation></ref>
      <ref id="bib1.bibx29"><label>Munger et al.(2012)Munger, Loescher, and Luo</label><mixed-citation>Munger, J. W., Loescher, H. W., and Luo, H.: Measurement, Tower, and Site Design Considerations, in: Eddy Covariance – A Practical Guide to Measurement and Data Analysis, edited by: Aubinet, M., Vesala, T., and Papale, D., Springer Netherlands, Dordrecht, <ext-link xlink:href="https://doi.org/10.1007/978-94-007-2351-1_2" ext-link-type="DOI">10.1007/978-94-007-2351-1_2</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx30"><label>Nemitz et al.(2018)</label><mixed-citation>Nemitz, E., Mammarella, I., Ibrom, A., Aurela, M., Burba, G. G., Dengel, S., Gielen, B., Grelle, A., Heinesch, B., Herbst, M., Hörtnagl, L., Klemedtsson, L., Lindroth, A., Lohila, A., McDermitt, D. K., Meier, P., Merbold, L., Nelson, D., Nicolini, G., Nilsson, M. B., Peltola, O., Rinne, J., and Zahniser, M.: Standardisation of eddy-covariance flux measurements of methane and nitrous oxide, Int.  Agrophys., 32, 517–549, <ext-link xlink:href="https://doi.org/10.1515/intag-2017-0042" ext-link-type="DOI">10.1515/intag-2017-0042</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx31"><label>Nicolini et al.(2026)</label><mixed-citation>Nicolini, G., Durden, D., Fiore, L. D., Florian, C., Sabbatini, S., Gielen, B., Iserbyt, A., Loubet, B., Mammarella, I., Mariotti, A., de Beeck, M., Slemmons, C., Trotta, C., Young, A., Chabbi, A., Feigenwinter, I., Heinesch, B., Kowalska, N., Mauder, M., Šigut, L., van der Molen, M., Campos, F. B., Berveiller, D., Brümmer, C., Cuntz, M., Domec, J.-C., Dumont, B., Fares, S., Gianelle, D., Jensen, R., Kalalian, C., Kljun, N., Lange, H., Limousin, J.-M., Lundin, E., Manco, A., Montagnani, L., Nemitz, E., Peichl, M., Rinne, E., Roland, M., Schmidt, M., Simioni, G., Thomas, A., Vincke, C., and Papale, D.: Bridging the Energy Balance Gap in Eddy-Covariance Measurements: Insights From Standardized Network Data, Glob. Change Biol., 32, e70892, <ext-link xlink:href="https://doi.org/10.1111/gcb.70892" ext-link-type="DOI">10.1111/gcb.70892</ext-link>, 2026.</mixed-citation></ref>
      <ref id="bib1.bibx32"><label>Ohtaki(1985)</label><mixed-citation>Ohtaki, E.: On the similarity in atmospheric fluctuations of carbon dioxide, water vapor and temperature over vegetated fields, Bound.-Lay. Meteorol., 32, 25–37, <ext-link xlink:href="https://doi.org/10.1007/BF00120712" ext-link-type="DOI">10.1007/BF00120712</ext-link>, 1985.</mixed-citation></ref>
      <ref id="bib1.bibx33"><label>Pastorello et al.(2020)</label><mixed-citation>Pastorello, G., Trotta, C., Canfora, E., Chu, H., Christianson, D., Cheah, Y.-W., Poindexter, C., Chen, J., Elbashandy, A., Humphrey, M., Isaac, P., Polidori, D., Reichstein, M., Ribeca, A., Van Ingen, C., Vuichard, N., Zhang, L., Amiro, B., Ammann, C., Arain, M. A., Ardö, J., Arkebauer, T., Arndt, S. K., Arriga, N., Aubinet, M., Aurela, M., Baldocchi, D., Barr, A., Beamesderfer, E., Marchesini, L. B., Bergeron, O., Beringer, J., Bernhofer, C., Berveiller, D., Billesbach, D., Black, T. A., Blanken, P. D., Bohrer, G., Boike, J., Bolstad, P. V., Bonal, D., Bonnefond, J.-M., Bowling, D. R., Bracho, R., Brodeur, J., Brümmer, C., Buchmann, N., Burban, B., Burns, S. P., Buysse, P., Cale, P., Cavagna, M., Cellier, P., Chen, S., Chini, I., Christensen, T. R., Cleverly, J., Collalti, A., Consalvo, C., Cook, B. D., Cook, D., Coursolle, C., Cremonese, E., Curtis, P. S., D’Andrea, E., Da Rocha, H., Dai, X., Davis, K. J., Cinti, B. D., Grandcourt, A. D., Ligne, A. D., De Oliveira, R. C., Delpierre, N., Desai, A. R., Di Bella, C. M., Tommasi, P. D., Dolman, H., Domingo, F., Dong, G., Dore, S., Duce, P., Dufrêne, E., Dunn, A., Dušek, J., Eamus, D., Eichelmann, U., ElKhidir, H. A. M., Eugster, W., Ewenz, C. M., Ewers, B., Famulari, D., Fares, S., Feigenwinter, I., Feitz, A., Fensholt, R., Filippa, G., Fischer, M., Frank, J., Galvagno, M., Gharun, M., Gianelle, D., Gielen, B., Gioli, B., Gitelson, A., Goded, I., Goeckede, M., Goldstein, A. H., Gough, C. M., Goulden, M. L., Graf, A., Griebel, A., Gruening, C., Grünwald, T., Hammerle, A., Han, S., Han, X., Hansen, B. U., Hanson, C., Hatakka, J., He, Y., Hehn, M., Heinesch, B., Hinko-Najera, N., Hörtnagl, L., Hutley, L., Ibrom, A., Ikawa, H., Jackowicz-Korczynski, M., Janouš, D., Jans, W., Jassal, R., Jiang, S., Kato, T., Khomik, M., Klatt, J., Knohl, A., Knox, S., Kobayashi, H., Koerber, G., Kolle, O., Kosugi, Y., Kotani, A., Kowalski, A., Kruijt, B., Kurbatova, J., Kutsch, W. L., Kwon, H., Launiainen, S., Laurila, T., Law, B., Leuning, R., Li, Y., Liddell, M., Limousin, J.-M., Lion, M., Liska, A. J., Lohila, A., López-Ballesteros, A., López-Blanco, E., Loubet, B., Loustau, D., Lucas-Moffat, A., Lüers, J., Ma, S., Macfarlane, C., Magliulo, V., Maier, R., Mammarella, I., Manca, G., Marcolla, B., Margolis, H. A., Marras, S., Massman, W., Mastepanov, M., Matamala, R., Matthes, J. H., Mazzenga, F., McCaughey, H., McHugh, I., McMillan, A. M. S., Merbold, L., Meyer, W., Meyers, T., Miller, S. D., Minerbi, S., Moderow, U., Monson, R. K., Montagnani, L., Moore, C. E., Moors, E., Moreaux, V., Moureaux, C., Munger, J. W., Nakai, T., Neirynck, J., Nesic, Z., Nicolini, G., Noormets, A., Northwood, M., Nosetto, M., Nouvellon, Y., Novick, K., Oechel, W., Olesen, J. E., Ourcival, J.-M., Papuga, S. A., Parmentier, F.-J., Paul-Limoges, E., Pavelka, M., Peichl, M., Pendall, E., Phillips, R. P., Pilegaard, K., Pirk, N., Posse, G., Powell, T., Prasse, H., Prober, S. M., Rambal, S., Rannik, Ü., Raz-Yaseef, N., Rebmann, C., Reed, D., Dios, V. R. D., Restrepo-Coupe, N., Reverter, B. R., Roland, M., Sabbatini, S., Sachs, T., Saleska, S. R., Sánchez-Cañete, E. P., Sanchez-Mejia, Z. M., Schmid, H. P., Schmidt, M., Schneider, K., Schrader, F., Schroder, I., Scott, R. L., Sedlák, P., Serrano-Ortíz, P., Shao, C., Shi, P., Shironya, I., Siebicke, L., Šigut, L., Silberstein, R., Sirca, C., Spano, D., Steinbrecher, R., Stevens, R. M., Sturtevant, C., Suyker, A., Tagesson, T., Takanashi, S., Tang, Y., Tapper, N., Thom, J., Tomassucci, M., Tuovinen, J.-P., Urbanski, S., Valentini, R., Van Der Molen, M., Van Gorsel, E., Van Huissteden, K., Varlagin, A., Verfaillie, J., Vesala, T., Vincke, C., Vitale, D., Vygodskaya, N., Walker, J. P., Walter-Shea, E., Wang, H., Weber, R., Westermann, S., Wille, C., Wofsy, S., Wohlfahrt, G., Wolf, S., Woodgate, W., Li, Y., Zampedri, R., Zhang, J., Zhou, G., Zona, D., Agarwal, D., Biraud, S., Torn, M., and Papale, D.: The FLUXNET2015 dataset and the ONEFlux processing pipeline for eddy covariance data, Scientific Data, 7, 225, <ext-link xlink:href="https://doi.org/10.1038/s41597-020-0534-3" ext-link-type="DOI">10.1038/s41597-020-0534-3</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx34"><label>Peltola et al.(2021)Peltola, Aslan, Ibrom, Nemitz, Rannik, and Mammarella</label><mixed-citation>Peltola, O., Aslan, T., Ibrom, A., Nemitz, E., Rannik, Ü., and Mammarella, I.: The high-frequency response correction of eddy covariance fluxes – Part 1: An experimental approach and its interdependence with the time-lag estimation, Atmos. Meas. Tech., 14, 5071–5088, <ext-link xlink:href="https://doi.org/10.5194/amt-14-5071-2021" ext-link-type="DOI">10.5194/amt-14-5071-2021</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx35"><label>Polonik et al.(2019)Polonik, Chan, Billesbach, Burba, Li, Nottrott, Bogoev, Conrad, and Biraud</label><mixed-citation>Polonik, P., Chan, W. S., Billesbach, D. P., Burba, G., Li, J., Nottrott, A., Bogoev, I., Conrad, B., and Biraud, S. C.: Comparison of gas analyzers for eddy covariance: Effects of analyzer type and spectral corrections on fluxes, Agr. Forest Meteorol., 272–273, 128–142, <ext-link xlink:href="https://doi.org/10.1016/j.agrformet.2019.02.010" ext-link-type="DOI">10.1016/j.agrformet.2019.02.010</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx36"><label>Rebmann et al.(2018)Rebmann, Aubinet, Schmid, Arriga, Aurela, Burba, Clement, De Ligne, Fratini, Gielen, Grace, Graf, Gross, Haapanala, Herbst, Hörtnagl, Ibrom, Joly, Kljun, Kolle, Kowalski, Lindroth, Loustau, Mammarella, Mauder, Merbold, Metzger, Mölder, Montagnani, Papale, Pavelka, Peichl, Roland, Serrano-Ortiz, Siebicke, Steinbrecher, Tuovinen, Vesala, Wohlfahrt, and Franz</label><mixed-citation>Rebmann, C., Aubinet, M., Schmid, H., Arriga, N., Aurela, M., Burba, G., Clement, R., De Ligne, A., Fratini, G., Gielen, B., Grace, J., Graf, A., Gross, P., Haapanala, S., Herbst, M., Hörtnagl, L., Ibrom, A., Joly, L., Kljun, N., Kolle, O., Kowalski, A., Lindroth, A., Loustau, D., Mammarella, I., Mauder, M., Merbold, L., Metzger, S., Mölder, M., Montagnani, L., Papale, D., Pavelka, M., Peichl, M., Roland, M., Serrano-Ortiz, P., Siebicke, L., Steinbrecher, R., Tuovinen, J.-P., Vesala, T., Wohlfahrt, G., and Franz, D.: ICOS eddy covariance flux-station site setup: a review, Int. Agrophys., 32, 471–494, <ext-link xlink:href="https://doi.org/10.1515/intag-2017-0044" ext-link-type="DOI">10.1515/intag-2017-0044</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx37"><label>Reichstein et al.(2005)Reichstein, Falge, Baldocchi, Papale, Aubinet, Berbigier, Bernhofer, Buchmann, Gilmanov, Granier, Grunwald, Havrankova, Ilvesniemi, Janous, Knohl, Laurila, Lohila, Loustau, Matteucci, Meyers, Miglietta, Ourcival, Pumpanen, Rambal, Rotenberg, Sanz, Tenhunen, Seufert, Vaccari, Vesala, Yakir, and Valentini</label><mixed-citation>Reichstein, M., Falge, E., Baldocchi, D., Papale, D., Aubinet, M., Berbigier, P., Bernhofer, C., Buchmann, N., Gilmanov, T., Granier, A., Grunwald, T., Havrankova, K., Ilvesniemi, H., Janous, D., Knohl, A., Laurila, T., Lohila, A., Loustau, D., Matteucci, G., Meyers, T., Miglietta, F., Ourcival, J.-M., Pumpanen, J., Rambal, S., Rotenberg, E., Sanz, M., Tenhunen, J., Seufert, G., Vaccari, F., Vesala, T., Yakir, D., and Valentini, R.: On the separation of net ecosystem exchange into assimilation and ecosystem respiration: review and improved algorithm, Glob. Change Biol., 11, 1424–1439, <ext-link xlink:href="https://doi.org/10.1111/j.1365-2486.2005.001002.x" ext-link-type="DOI">10.1111/j.1365-2486.2005.001002.x</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bibx38"><label>Reitz et al.(2022)Reitz, Graf, Schmidt, Ketzler, and Leuchner</label><mixed-citation>Reitz, O., Graf, A., Schmidt, M., Ketzler, G., and Leuchner, M.: Effects of Measurement Height and Low-Pass-Filtering Corrections on Eddy-Covariance Flux Measurements Over a Forest Clearing with Complex Vegetation, Bound.-Lay. Meteorol., 184, 277–299, <ext-link xlink:href="https://doi.org/10.1007/s10546-022-00700-1" ext-link-type="DOI">10.1007/s10546-022-00700-1</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx39"><label>Sabbatini and Papale(2017)</label><mixed-citation>Sabbatini, S. and Papale, D.: Instructions for turbulent flux measurements of CO2, energy and momentum, <uri>https://www.icos-etc.eu/icos/documents/instructions</uri> (last access: 22 September 2026),  2017.</mixed-citation></ref>
      <ref id="bib1.bibx40"><label>Sabbatini et al.(2018)Sabbatini, Mammarella, Arriga, Fratini, Graf, Hörtnagl, Ibrom, Longdoz, Mauder, Merbold, Metzger, Montagnani, Pitacco, Rebmann, Sedlák, Šigut, Vitale, and Papale</label><mixed-citation>Sabbatini, S., Mammarella, I., Arriga, N., Fratini, G., Graf, A., Hörtnagl, L., Ibrom, A., Longdoz, B., Mauder, M., Merbold, L., Metzger, S., Montagnani, L., Pitacco, A., Rebmann, C., Sedlák, P., Šigut, L., Vitale, D., and Papale, D.: Eddy covariance raw data processing for <inline-formula><mml:math id="M328" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and energy fluxes calculation at ICOS ecosystem stations, Int. Agrophys., 32, 495–515, <ext-link xlink:href="https://doi.org/10.1515/intag-2017-0043" ext-link-type="DOI">10.1515/intag-2017-0043</ext-link>, 2018. </mixed-citation></ref>
      <ref id="bib1.bibx41"><label>Smidt et al.(2025)Smidt, Wanner, Ibrom, Schmid, and Mauder</label><mixed-citation>Smidt, J., Wanner, L., Ibrom, A., Schmid, H., and Mauder, M.: High-frequency attenuation in eddy covariance measurements from the LI-7200 IRGA with various heating and filter configurations – a spectral correction approach, Agr. Forest Meteorol., 361, 110312, <ext-link xlink:href="https://doi.org/10.1016/j.agrformet.2024.110312" ext-link-type="DOI">10.1016/j.agrformet.2024.110312</ext-link>, 2025.</mixed-citation></ref>
      <ref id="bib1.bibx42"><label>Su et al.(2004)Su, Schmid, Grimmond, Vogel, and Oliphant</label><mixed-citation>Su, H.-B., Schmid, H. P., Grimmond, C. S. B., Vogel, C. S., and Oliphant, A. J.: Spectral Characteristics and Correction of Long-Term Eddy-Covariance Measurements Over Two Mixed Hardwood Forests in Non-Flat Terrain, Bound.-Lay. Meteorol., 110, 213–253, <ext-link xlink:href="https://doi.org/10.1023/A:1026099523505" ext-link-type="DOI">10.1023/A:1026099523505</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx43"><label>Vitale et al.(2020)Vitale, Fratini, Bilancia, Nicolini, Sabbatini, and Papale</label><mixed-citation>Vitale, D., Fratini, G., Bilancia, M., Nicolini, G., Sabbatini, S., and Papale, D.: A robust data cleaning procedure for eddy covariance flux measurements, Biogeosciences, 17, 1367–1391, <ext-link xlink:href="https://doi.org/10.5194/bg-17-1367-2020" ext-link-type="DOI">10.5194/bg-17-1367-2020</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx44"><label>Wintjen et al.(2020)Wintjen, Ammann, Schrader, and Brümmer</label><mixed-citation>Wintjen, P., Ammann, C., Schrader, F., and Brümmer, C.: Correcting high-frequency losses of reactive nitrogen flux measurements, Atmos. Meas. Tech., 13, 2923–2948, <ext-link xlink:href="https://doi.org/10.5194/amt-13-2923-2020" ext-link-type="DOI">10.5194/amt-13-2923-2020</ext-link>, 2020.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Spectral versus co-spectral correction of eddy-covariance fluxes: a multi-site assessment across the ICOS network</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Asanuma et al.(2007)Asanuma, Tamagawa, Ishikawa, Ma, Hayashi, Qi, and Wang</label><mixed-citation>
      
Asanuma, J., Tamagawa, I., Ishikawa, H., Ma, Y., Hayashi, T., Qi, Y., and Wang, J.: Spectral similarity between
scalars at very low frequencies in the unstable atmospheric surface layer over the Tibetan plateau,
Bound.-Lay. Meteorol., 122, 85–103, <a href="https://doi.org/10.1007/s10546-006-9096-y" target="_blank">https://doi.org/10.1007/s10546-006-9096-y</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Aslan et al.(2021)Aslan, Peltola, Ibrom, Nemitz, Rannik, and Mammarella</label><mixed-citation>
      
Aslan, T., Peltola, O., Ibrom, A., Nemitz, E., Rannik, Ü., and Mammarella, I.: The high-frequency response correction
of eddy covariance fluxes – Part 2: An experimental approach for analysing noisy measurements of small fluxes,
Atmos. Meas. Tech., 14, 5089–5106, <a href="https://doi.org/10.5194/amt-14-5089-2021" target="_blank">https://doi.org/10.5194/amt-14-5089-2021</a>, 2021. 
    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Aubinet et al.(2000)Aubinet, Grelle, Ibrom, Rannik, Moncrieff, Foken, Kowalski, Martin, Berbigier, Bernhofer,
Clement, Elbers, Granier, Grünwald, Morgenstern, Pilegaard, Rebmann, Snijders, Valentini, and
Vesala</label><mixed-citation>
       Aubinet, M., Grelle, A., Ibrom, A., Rannik, Ü., Moncrieff, J., Foken, T.,
Kowalski, A., Martin, P., Berbigier, P., Bernhofer, C., Clement, R., Elbers, J., Granier, A., Grünwald, T.,
Morgenstern, K., Pilegaard, K., Rebmann, C., Snijders, W., Valentini, R., and Vesala, T.: Estimates of the Annual
Net Carbon and Water Exchange of Forests: The EUROFLUX Methodology, in: Advances in Ecological
Research, Vol. 30, Elsevier, 113–175, <a href="https://doi.org/10.1016/S0065-2504(08)60018-5" target="_blank">https://doi.org/10.1016/S0065-2504(08)60018-5</a>, 2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Aubinet et al.(2012)Aubinet, Vesala, and Papale</label><mixed-citation>
       Aubinet, M., Vesala, T., and Papale, D.,
(Eds.): Eddy Covariance: A Practical Guide to Measurement and Data Analysis, Springer Netherlands,
Dordrecht, <a href="https://doi.org/10.1007/978-94-007-2351-1" target="_blank">https://doi.org/10.1007/978-94-007-2351-1</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Baldocchi(2014)</label><mixed-citation>
       Baldocchi, D.: Measuring fluxes of trace gases and energy between
ecosystems and the atmosphere – the state and future of the eddy covariance method, Glob. Change Biol., 20,
3600–3609, <a href="https://doi.org/10.1111/gcb.12649" target="_blank">https://doi.org/10.1111/gcb.12649</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>De Ligne et al.(2010)De Ligne, Heinesch, and Aubinet</label><mixed-citation>
       De Ligne, A., Heinesch, B., and
Aubinet, M.: New Transfer Functions for Correcting Turbulent Water Vapour Fluxes, Bound.-Lay. Meteorol.,
137, 205–221, <a href="https://doi.org/10.1007/s10546-010-9525-9" target="_blank">https://doi.org/10.1007/s10546-010-9525-9</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Emad(2023)</label><mixed-citation>
       Emad, A.: Optimal Frequency-Response Corrections for Eddy Covariance
Flux Measurements Using the Wiener Deconvolution Method, Bound.-Lay. Meteorol.,
<a href="https://doi.org/10.1007/s10546-023-00799-w" target="_blank">https://doi.org/10.1007/s10546-023-00799-w</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Eugster and Senn(1995)</label><mixed-citation>
       Eugster, W. and Senn, W.: A cospectral correction model for
measurement of turbulent NO<sub>2</sub> flux, Bound.-Lay. Meteorol., 74, 321–340, <a href="https://doi.org/10.1007/BF00712375" target="_blank">https://doi.org/10.1007/BF00712375</a>, 1995.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Faurès and  Heinesch(2026)</label><mixed-citation>
      
Faurès, A. and  Heinesch, B.: FreqCor (Version v1.3),  Zenodo [code], <a href="https://doi.org/10.5281/zenodo.22877082" target="_blank">https://doi.org/10.5281/zenodo.22877082</a>, 2026.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Foken et al.(2012a)Foken, Aubinet, and Leuning</label><mixed-citation>
       Foken, T., Aubinet, M., and Leuning, R.:
The Eddy Covariance Method, in: Eddy Covariance – A Practical Guide to Measurement and Data
Analysis, edited by: Aubinet, M., Vesala, T., and Papale, D., Springer Netherlands, Dordrecht,
<a href="https://doi.org/10.1007/978-94-007-2351-1_1" target="_blank">https://doi.org/10.1007/978-94-007-2351-1_1</a>, 2012a.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Foken et al.(2012b)Foken, Leuning, Oncley, Mauder, and Aubinet</label><mixed-citation>
       Foken, T.,
Leuning, R., Oncley, S. R., Mauder, M., and Aubinet, M.: Corrections and Data Quality Control, in: Eddy
Covariance – A Practical Guide to Measurement and Data Analysis, edited by: Aubinet, M., Vesala, T.,
and Papale, D., Springer Netherlands, Dordrecht, <a href="https://doi.org/10.1007/978-94-007-2351-1_4" target="_blank">https://doi.org/10.1007/978-94-007-2351-1_4</a>, 2012b.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Franz et al.(2018)Franz, Acosta, Altimir, Arriga, Arrouays, Aubinet, Aurela, Ayres, López-Ballesteros,
Barbaste, Berveiller, Biraud, Boukir, Brown, Brömmer, Buchmann, Burba, Carrara, Cescatti, Ceschia, Clement,
Cremonese, Crill, Darenova, Dengel, D'Odorico, Filippa, Fleck, Fratini, Fuß, Gielen, Gogo, Grace, Graf, Grelle,
Gross, Grönwald, Haapanala, Hehn, Heinesch, Heiskanen, Herbst, Herschlein, Hörtnagl, Hufkens, Ibrom, Jolivet, Joly,
Jones, Kiese, Klemedtsson, Kljun, Klumpp, Kolari, Kolle, Kowalski, Kutsch, Laurila, Ligne, Linder, Lindroth, Lohila,
Longdoz, Mammarella, Manise, Jiménez, Matteucci, Mauder, Meier, Merbold, Mereu, Metzger, Migliavacca, Mölder,
Montagnani, Moureaux, Nelson, Nemitz, Nicolini, Nilsson, Beeck, Osborne, Löfvenius, Pavelka, Peichl, Peltola,
Pihlatie, Pitacco, Pokorný, Pumpanen, Ratié, Rebmann, Roland, Sabbatini, Saby, Saunders, Schmid, Schrumpf, Sedlák,
Ortiz, Siebicke, Šigut, Silvennoinen, Simioni, Skiba, Sonnentag, Soudani, Soulé, Steinbrecher, Tallec, Thimonier,
Tuittila, Tuovinen, Vestin, Vincent, Vincke, Vitale, Waldner, Weslien, Wingate, Wohlfahrt, Zahniser, and
Vesala</label><mixed-citation>
       Franz, D., Acosta, M., Altimir, N., Arriga, N., Arrouays, D., Aubinet, M., Aurela, M.,
Ayres, E., López-Ballesteros, A., Barbaste, M., Berveiller, D., Biraud, S., Boukir, H., Brown, T., Brömmer, C.,
Buchmann, N., Burba, G., Carrara, A., Cescatti, A., Ceschia, E., Clement, R., Cremonese, E., Crill, P., Darenova, E.,
Dengel, S., D'Odorico, P., Filippa, G., Fleck, S., Fratini, G., Fuß, R., Gielen, B., Gogo, S., Grace, J., Graf, A.,
Grelle, A., Gross, P., Grönwald, T., Haapanala, S., Hehn, M., Heinesch, B., Heiskanen, J., Herbst, M., Herschlein, C.,
Hörtnagl, L., Hufkens, K., Ibrom, A., Jolivet, C., Joly, L., Jones, M., Kiese, R., Klemedtsson, L., Kljun, N.,
Klumpp, K., Kolari, P., Kolle, O., Kowalski, A., Kutsch, W., Laurila, T., Ligne, A. D., Linder, S., Lindroth, A.,
Lohila, A., Longdoz, B., Mammarella, I., Manise, T., Jiménez, S. M., Matteucci, G., Mauder, M., Meier, P.,
Merbold, L., Mereu, S., Metzger, S., Migliavacca, M., Mölder, M., Montagnani, L., Moureaux, C., Nelson, D.,
Nemitz, E., Nicolini, G., Nilsson, M. B., Beeck, M. O. M. D., Osborne, B., Löfvenius, M. O., Pavelka, M., Peichl, M.,
Peltola, O., Pihlatie, M., Pitacco, A., Pokorný, R., Pumpanen, J., Ratié, C., Rebmann, C., Roland, M., Sabbatini, S.,
Saby, N. P. A., Saunders, M., Schmid, H. P., Schrumpf, M., Sedlák, P., Ortiz, P. S., Siebicke, L., Šigut, L.,
Silvennoinen, H., Simioni, G., Skiba, U., Sonnentag, O., Soudani, K., Soulé, P., Steinbrecher, R., Tallec, T.,
Thimonier, A., Tuittila, E.-S., Tuovinen, J.-P., Vestin, P., Vincent, G., Vincke, C., Vitale, D., Waldner, P.,
Weslien, P., Wingate, L., Wohlfahrt, G., Zahniser, M., and Vesala, T.: Towards long-Term standardised carbon and
greenhouse gas observations for monitoring Europe's terrestrial ecosystems: A review, Int. Agrophys., 32, 439–455,
<a href="https://doi.org/10.1515/intag-2017-0039" target="_blank">https://doi.org/10.1515/intag-2017-0039</a>, cited By 2, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Fratini et al.(2012)Fratini, Ibrom, Arriga, Burba, and Papale</label><mixed-citation>
       Fratini, G., Ibrom, A.,
Arriga, N., Burba, G., and Papale, D.: Relative humidity effects on water vapour fluxes measured with closed-path
eddy-covariance systems with short sampling lines, Agr. Forest Meteorol., 165, 53–63,
<a href="https://doi.org/10.1016/j.agrformet.2012.05.018" target="_blank">https://doi.org/10.1016/j.agrformet.2012.05.018</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Horst(1997)</label><mixed-citation>
       Horst, T. W.: A simple formula for attenuation of Eddy fluxes
measured with first-order-response scalar sensors, Bound.-Lay. Meteorol., 82, 219–233,
<a href="https://doi.org/10.1023/A:1000229130034" target="_blank">https://doi.org/10.1023/A:1000229130034</a>, 1997.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Horst and Lenschow(2009)</label><mixed-citation>
       Horst, T. W. and Lenschow, D. H.: Attenuation of Scalar
Fluxes Measured with Spatially-displaced Sensors, Bound.-Lay. Meteorol., 130, 275–300,
<a href="https://doi.org/10.1007/s10546-008-9348-0" target="_blank">https://doi.org/10.1007/s10546-008-9348-0</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Hunt et al.(2016)Hunt, Laubach, Barthel, Fraser, and Phillips</label><mixed-citation>
       Hunt, J. E., Laubach, J.,
Barthel, M., Fraser, A., and Phillips, R. L.: Carbon budgets for an irrigated intensively grazed dairy pasture and an
unirrigated winter-grazed pasture, Biogeosciences, 13, 2927–2944, <a href="https://doi.org/10.5194/bg-13-2927-2016" target="_blank">https://doi.org/10.5194/bg-13-2927-2016</a>,
2016. 
    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Ibrom et al.(2007)Ibrom, Dellwik, Flyvbjerg, Jensen, and Pilegaard</label><mixed-citation>
       Ibrom, A.,
Dellwik, E., Flyvbjerg, H., Jensen, N. O., and Pilegaard, K.: Strong low-pass filtering effects on water vapour flux
measurements with closed-path eddy correlation systems, Agr. Forest Meteorol., 147, 140–156,
<a href="https://doi.org/10.1016/j.agrformet.2007.07.007" target="_blank">https://doi.org/10.1016/j.agrformet.2007.07.007</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>ICOS RI et al.(2025)</label><mixed-citation>
      
ICOS RI, Aalto, J., Aalto, P., Aaltonen, H., Aiguier, T., Akubia, J.,  Ala-Könni, J., Alivernini, A., Alonso, L., Aluome, C., Andersson, T., Arriga, N., Aurela, M., BRECHET, L., Baab, F., Back, J., Bagheri, S., Baltes, U., Baneschi, I., Barral, H., Barten, S., Bastos Campos, F., Baur, T., Bauters, M., Bazot, S., Beauclair, P., Becker, N., Behrens, N., Belelli Marchesini, L., Bergström, G., Bernhofer, C., Berveiller, D., Biermann, T., Bignotti, L., Biron, R., Bloor, J., Bodson, B., Boeckx, P., Boeske, L., Bogaerts, G., Bonal, D., Boon, G., Bornet, F., Bortoli, M., Boschetti, F., Bosio, I., Bresseleers, S., Brut, A., Brümmer, C., Buchmann, N., Bulonza, E., Burban, B., Burri, S., Buysse, P., Båth, A., Calandrelli, D., Calvet, J.-C., Canut-Rocafort, G., Carrara, A., Cash, J., Cavagna, M., Ceschia, E., Chabbi, A., Chan, T., Chebbi, W., Chebil, B., Chianucci, F., Chipeaux, C., Chopin, H., Christen, A., Chrysoulakis, N., Claverie, N., Cobbe, I., Cohard, J.-M., Colosse, D., Conte, A., Corsanici, R., Coulaud, C., Courtois, P., Coyle, M., Cremonese, E., Crill, P., Cuntz, M., Cuocolo, D., Czerný, R., DEPUYDT, J., Daelman, R., Darenová, E., Darsonville, O., De Ligne, A., De Meulder, T., De Simon, G., Decau, M.-L., Dejosez, S., Dell'Acqua, A., Delorme, J.-P., Delpierre, N., Demoulin, L., Denou, J.-L., Di Tommasi, P., Dienstbach, L., Dignam, R., Dolfus, D., Domec, J.-C., Douxfils, B., Drösler, M., Drüe, C., Dufrêne, E., Dumont, B., Durand, B., Dusek, J., Eberl, J., Eichelmann, U., Ekili, D., Engelmann, T., Esposito, A., Esser, O., Etienne, J.-C., Etzold, S., Eugster, W., Famulari, D., Fares, S., Faurès, A., Fauvel, Y., Feigenwinter, C., Feigenwinter, I., Feldmann, I., Ferraris, D., Filippa, G., Fincham, W., Finco, A., Fischer, M., Flechard, C., Folino, G., Foltýnová, L., Foret, J., Foulquier, A., François, B., Friborg, T., Galliot, J.-N., Galvagno, M., Garcia Quiros, I., Garrigou, C., Gastal, F., Geilfus, N.-X., Gerosa, G., Gessler, A., Gharun, M., Giamberini, M., Gianelle, D., Gibrin, H., Gimper, S., Gioli, B., Girardin, C., Goded, I., Graf, A., Granouillac, F., Grehan, E., Grenier, M., Grudd, H., Grünwald, T., Guillot, T., Guzman, R., Hamon, Y., Harvey, D., Hatakka, J., Haustein, A., Hautmann, D., Hehn, M., Heinesch, B., Helfter, C., Heliasz, M., Herbst, M., Hildebrandt, A., Holst, J., Holst, T., Holtmann, A., Hortnagl, L., Hug, C., Huguet, C., Häni, M., Ibrom, A., Ilardi, F., Jackowicz-Korczynski, M. A., Jacotot, A., Janssens, I., Jensen, R., Jocher, G., Joetzjer, E., Jones, M., Järvi, L., Kalalian, C., Kempf, J., Kempka, P., Keronen, P., Kettler, M., Kimbesa, F., Kivalov, S., Klatt, J., Klimo, P., Kljun, N., Klumpp, K., Kogxylakis, G., Kolari, P., Kolbe, S., Korkiakoski, M., Korrensalo, A., Kowalska, N., Kozii, N., Krejza, J., Kristoffersson, A., Kruijt, B., Kruszewski, A., Kulmala, L., Kumar, S., Kummer, S., Laakso, H., Lafont, S., Lange, H., Lange Rønn, E., Larmanou, E., Laurila, T., Leeson, S., Lefevre, L., Lehner, I., Lemaire, B., Leonard, J., Levula, J., Levy, P., Liechti, K., Liger, L., Lily, J.-B., Limousin, J.-M., Linderson, M.-L., Lindgren, K., Lo Cascio, M., Lodsgaard Justesen, M., Lofvenius, P., Lohila, A., Longdoz, B., Lootens, R., Loubet, B., Loustau, D., Lucarini, A., Lundin, E., López, R., López-Blanco, E., Magliulo, V., Mammarella, I., Manco, A., Manise, T., Marcolla, B., Marek, M. V., Marklund, P., Marloie, O., Marras, S., Martin, R., Martin Saint Paul, N., Marty, M., Martín, M. P., Marzuoli, R., Matilainen, T., Mattes, J., Matteucci, M., Mauder, M., Maurel, W., Mbifo, J., Meggio, F., Meier, F., Meier, P., Meire, A., Meis, J., Meissner, H., Mensah, C., Meyer, H., Michaud, L., Minerbi, S., Moderow, U., Molder, M., Montagnani, L., Moreno, G., Moretti, V., Morfin, A., Morra di Cella, U., Mullinger, N., Mäkelä, T., Männikkö, M., Männistö, E., Møller, F., Naiken, A., Naseer, M., Nemitz, E., Nezval, O., Nilsson, M., Norkko, J., Ocallaghan, F., Ojala, A., Orgun, A., Ottosson-Löfvenius, M., Ourcival, J.-M., Paasch, S., Paci, A., Pavelka, M., Pavot, L., Peichl, M., Peressotti, A., Perot-Guillaume, C., Perrot, C., Pihlatie, M., Pilegaard, K., Pilkottu, R., Piret, A., Pitacco, A., Plapp, T., Plebani, D., Politakos, K., Prasse, H., Provenzale, A., Pumpanen, J., Putzolu, S., Raco, B., Rainne, J., Rakos, N., Rebmann, C., Redepenning, D., Rinne, J., Rodeghiero, M., Roland, M., Rudd, D., Ryhti, K., Røjle Christensen, T., Sahoo, G., Salze, P., Schaarup Sørensen, J., Schindler, D., Schlaipfer, M., Schmidt, M., Schmidt, P., Schmitt Oehler, M., Schrader, F., Segers, J., Shivhalli Gopal, A., Sibret, T., Siivola, E., Simioni, G., Sirca, C., Smith, P., Snellen, H., Sorgi, T., Soudani, K., Spano, D., Spence, K., Spyridakis, N., Stagakis, S., Staník, K., Staudinger, M., Stecher, M., Stellner, S., Stutz, T., Suopajärvi, S., Sutter, F., Taipale, R., Tallec, T., Tenca, F., Tezza, L., Thimonier Rickenmann, A., Thyrion, T., Tomelleri, E., Trotsiuk, V., Trusina, J., Tuittila, E.-S., Tuovinen, J.-P., Tyssandier, J., Vagnoli, C., Valay, J.-G., Van Damme, F., Van Look, J., Vande Sompele, A., Vandome, E., Varjonen, S., Vendrame, N., Ventura, M., Verbeeck, H., Vesala, T., Vescovo, L., Vincent, G., Vincke, C., Vitale, L., Vivaldo, G., Voisin, D., Vágner, L., Vähä, A., Waldner, P., Wiesen, R., Wilhelm, M., Winck, B., Yeung, K., Zaldei, A., Zampedri, R., Zawilski, B., Zenone, T., Zhao, H., Zhao, J., Zhu, J., Zimmermann, S., Zweifel, R., de Berranger, C., van Dijk, N., van der Molen, M., Šigut, L., and Šlížek, J.: Ecosystem final quality (L2) product in ETC-Archive format – release 2025-1, medium: Arbitrary ZIP archive, ICOS ETC half-hourly product CSV Version Number: 1.0, ICOS ERIC – Carbon Portal [data set], <a href="https://doi.org/10.18160/S6HM-CP8Q" target="_blank">https://doi.org/10.18160/S6HM-CP8Q</a>, 2025.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Kaimal et al.(1972)Kaimal, Wyngaard, Izumi, and Coté</label><mixed-citation>
       Kaimal, J. C., Wyngaard, J. C.,
Izumi, Y., and Coté, O. R.: Spectral characteristics of surface-layer turbulence, Q. J. Roy. Meteor. Soc., 98,
563–589, <a href="https://doi.org/10.1002/qj.49709841707" target="_blank">https://doi.org/10.1002/qj.49709841707</a>, 1972.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Mamadou et al.(2016)Mamadou, Gourlez de la Motte, De Ligne, Heinesch, and Aubinet</label><mixed-citation>
      
Mamadou, O., Gourlez de la Motte, L., De Ligne, A., Heinesch, B., and Aubinet, M.: Sensitivity of the annual net
ecosystem exchange to the cospectral model used for high frequency loss corrections at a grazed grassland site,
Agr. Forest Meteorol., 228–229, 360–369, <a href="https://doi.org/10.1016/j.agrformet.2016.06.008" target="_blank">https://doi.org/10.1016/j.agrformet.2016.06.008</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Mammarella et al.(2009)Mammarella, Launiainen, Gronholm, Keronen, Pumpanen, Rannik, and
Vesala</label><mixed-citation>
       Mammarella, I., Launiainen, S., Gronholm, T., Keronen, P., Pumpanen, J., Rannik,
Ü., and Vesala, T.: Relative Humidity Effect on the High-Frequency Attenuation of Water Vapor Flux
Measured by a Closed-Path Eddy Covariance System, <a href="https://doi.org/10.1175/2009JTECHA1179.1" target="_blank">https://doi.org/10.1175/2009JTECHA1179.1</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Mammarella et al.(2016)Mammarella, Peltola, Nordbo, Järvi, and Rannik</label><mixed-citation>
      
Mammarella, I., Peltola, O., Nordbo, A., Järvi, L., and Rannik, Ü.: Quantifying the uncertainty of eddy covariance
fluxes due to the use of different software packages and combinations of processing steps in two contrasting
ecosystems, Atmos. Meas. Tech., 9, 4915–4933, <a href="https://doi.org/10.5194/amt-9-4915-2016" target="_blank">https://doi.org/10.5194/amt-9-4915-2016</a>, 2016. 
    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Massman(2000)</label><mixed-citation>
       Massman, W.: A simple method for estimating frequency response
corrections for eddy covariance systems, Agr. Forest Meteorol., 104, 185–198, <a href="https://doi.org/10.1016/S0168-1923(00)00164-7" target="_blank">https://doi.org/10.1016/S0168-1923(00)00164-7</a>,
2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Massman and Clement(2005)</label><mixed-citation>
       Massman, W. and Clement, R.: Uncertainty in Eddy
Covariance Flux Estimates Resulting from Spectral Attenuation, in: Handbook of Micrometeorology: A
Guide for Surface Flux Measurement and Analysis, edited by: Lee, X., Massman, W., and Law, B., Springer
Netherlands, Dordrecht, 67–99, <a href="https://doi.org/10.1007/1-4020-2265-4_4" target="_blank">https://doi.org/10.1007/1-4020-2265-4_4</a>, 2005.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Mauder et al.(2024)Mauder, Jung, Stoy, Nelson, and Wanner</label><mixed-citation>
       Mauder, M., Jung, M.,
Stoy, P., Nelson, J., and Wanner, L.: Energy balance closure at FLUXNET sites revisited, Agr. Forest Meteorol., 358,
110235, <a href="https://doi.org/10.1016/j.agrformet.2024.110235" target="_blank">https://doi.org/10.1016/j.agrformet.2024.110235</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Moncrieff et al.(2004)Moncrieff, Clement, Finnigan, and Meyers</label><mixed-citation>
       Moncrieff, J.,
Clement, R., Finnigan, J., and Meyers, T.: Averaging, Detrending, and Filtering of Eddy Covariance Time
Series, in: Handbook of Micrometeorology: A Guide for Surface Flux Measurement and Analysis, edited
by: Lee, X., Massman, W., and Law, B., Springer Netherlands, Dordrecht, 7–31, <a href="https://doi.org/10.1007/1-4020-2265-4_2" target="_blank">https://doi.org/10.1007/1-4020-2265-4_2</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Moncrieff et al.(1997)Moncrieff, Massheder, de Bruin, Elbers, Friborg, Heusinkveld, Kabat, Scott, Soegaard,
and Verhoef</label><mixed-citation>
       Moncrieff, J. B., Massheder, J. M., de Bruin, H., Elbers, J., Friborg, T.,
Heusinkveld, B., Kabat, P., Scott, S., Soegaard, H., and Verhoef, A.: A system to measure surface fluxes of momentum,
sensible heat, water vapour and carbon dioxide, J. Hydrol., 188–189, 589–611, <a href="https://doi.org/10.1016/S0022-1694(96)03194-0" target="_blank">https://doi.org/10.1016/S0022-1694(96)03194-0</a>,
1997.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Moore(1986)</label><mixed-citation>
       Moore, C. J.: Frequency response corrections for eddy correlation systems,
Bound.-Lay. Meteorol., 37, 17–35, <a href="https://doi.org/10.1007/BF00122754" target="_blank">https://doi.org/10.1007/BF00122754</a>, 1986.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Munger et al.(2012)Munger, Loescher, and Luo</label><mixed-citation>
       Munger, J. W., Loescher, H. W., and
Luo, H.: Measurement, Tower, and Site Design Considerations, in: Eddy Covariance – A Practical Guide
to Measurement and Data Analysis, edited by: Aubinet, M., Vesala, T., and Papale, D., Springer Netherlands,
Dordrecht, <a href="https://doi.org/10.1007/978-94-007-2351-1_2" target="_blank">https://doi.org/10.1007/978-94-007-2351-1_2</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Nemitz et al.(2018)</label><mixed-citation>
      
Nemitz, E., Mammarella, I., Ibrom, A., Aurela, M., Burba, G. G., Dengel, S.,
Gielen, B., Grelle, A., Heinesch, B., Herbst, M., Hörtnagl, L., Klemedtsson, L., Lindroth, A., Lohila, A.,
McDermitt, D. K., Meier, P., Merbold, L., Nelson, D., Nicolini, G., Nilsson, M. B., Peltola, O., Rinne, J., and
Zahniser, M.: Standardisation of eddy-covariance flux measurements of methane and nitrous oxide, Int.  Agrophys., 32,
517–549, <a href="https://doi.org/10.1515/intag-2017-0042" target="_blank">https://doi.org/10.1515/intag-2017-0042</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Nicolini et al.(2026)</label><mixed-citation>
      
Nicolini, G., Durden, D., Fiore, L. D., Florian, C., Sabbatini, S., Gielen, B.,
Iserbyt, A., Loubet, B., Mammarella, I., Mariotti, A., de Beeck, M., Slemmons, C., Trotta, C., Young, A., Chabbi, A.,
Feigenwinter, I., Heinesch, B., Kowalska, N., Mauder, M., Šigut, L., van der Molen, M., Campos, F. B., Berveiller, D.,
Brümmer, C., Cuntz, M., Domec, J.-C., Dumont, B., Fares, S., Gianelle, D., Jensen, R., Kalalian, C., Kljun, N.,
Lange, H., Limousin, J.-M., Lundin, E., Manco, A., Montagnani, L., Nemitz, E., Peichl, M., Rinne, E., Roland, M.,
Schmidt, M., Simioni, G., Thomas, A., Vincke, C., and Papale, D.: Bridging the Energy Balance Gap in Eddy-Covariance
Measurements: Insights From Standardized Network Data, Glob. Change Biol., 32, e70892, <a href="https://doi.org/10.1111/gcb.70892" target="_blank">https://doi.org/10.1111/gcb.70892</a>, 2026.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>Ohtaki(1985)</label><mixed-citation>
       Ohtaki, E.: On the similarity in atmospheric fluctuations of carbon
dioxide, water vapor and temperature over vegetated fields, Bound.-Lay. Meteorol., 32, 25–37,
<a href="https://doi.org/10.1007/BF00120712" target="_blank">https://doi.org/10.1007/BF00120712</a>, 1985.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Pastorello et al.(2020)</label><mixed-citation>
      
Pastorello, G., Trotta, C., Canfora, E., Chu, H., Christianson, D., Cheah, Y.-W., Poindexter, C., Chen, J., Elbashandy, A., Humphrey, M., Isaac, P., Polidori, D., Reichstein, M., Ribeca, A., Van Ingen, C., Vuichard, N., Zhang, L., Amiro, B., Ammann, C., Arain, M. A., Ardö, J., Arkebauer, T., Arndt, S. K., Arriga, N., Aubinet, M., Aurela, M., Baldocchi, D., Barr, A., Beamesderfer, E., Marchesini, L. B., Bergeron, O., Beringer, J., Bernhofer, C., Berveiller, D., Billesbach, D., Black, T. A., Blanken, P. D., Bohrer, G., Boike, J., Bolstad, P. V., Bonal, D., Bonnefond, J.-M., Bowling, D. R., Bracho, R., Brodeur, J., Brümmer, C., Buchmann, N., Burban, B., Burns, S. P., Buysse, P., Cale, P., Cavagna, M., Cellier, P., Chen, S., Chini, I., Christensen, T. R., Cleverly, J., Collalti, A., Consalvo, C., Cook, B. D., Cook, D., Coursolle, C., Cremonese, E., Curtis, P. S., D’Andrea, E., Da Rocha, H., Dai, X., Davis, K. J., Cinti, B. D., Grandcourt, A. D., Ligne, A. D., De Oliveira, R. C., Delpierre, N., Desai, A. R., Di Bella, C. M., Tommasi, P. D., Dolman, H., Domingo, F., Dong, G., Dore, S., Duce, P., Dufrêne, E., Dunn, A., Dušek, J., Eamus, D., Eichelmann, U., ElKhidir, H. A. M., Eugster, W., Ewenz, C. M., Ewers, B., Famulari, D., Fares, S., Feigenwinter, I., Feitz, A., Fensholt, R., Filippa, G., Fischer, M., Frank, J., Galvagno, M., Gharun, M., Gianelle, D., Gielen, B., Gioli, B., Gitelson, A., Goded, I., Goeckede, M., Goldstein, A. H., Gough, C. M., Goulden, M. L., Graf, A., Griebel, A., Gruening, C., Grünwald, T., Hammerle, A., Han, S., Han, X., Hansen, B. U., Hanson, C., Hatakka, J., He, Y., Hehn, M., Heinesch, B., Hinko-Najera, N., Hörtnagl, L., Hutley, L., Ibrom, A., Ikawa, H., Jackowicz-Korczynski, M., Janouš, D., Jans, W., Jassal, R., Jiang, S., Kato, T., Khomik, M., Klatt, J., Knohl, A., Knox, S., Kobayashi, H., Koerber, G., Kolle, O., Kosugi, Y., Kotani, A., Kowalski, A., Kruijt, B., Kurbatova, J., Kutsch, W. L., Kwon, H., Launiainen, S., Laurila, T., Law, B., Leuning, R., Li, Y., Liddell, M., Limousin, J.-M., Lion, M., Liska, A. J., Lohila, A., López-Ballesteros, A., López-Blanco, E., Loubet, B., Loustau, D., Lucas-Moffat, A., Lüers, J., Ma, S., Macfarlane, C., Magliulo, V., Maier, R., Mammarella, I., Manca, G., Marcolla, B., Margolis, H. A., Marras, S., Massman, W., Mastepanov, M., Matamala, R., Matthes, J. H., Mazzenga, F., McCaughey, H., McHugh, I., McMillan, A. M. S., Merbold, L., Meyer, W., Meyers, T., Miller, S. D., Minerbi, S., Moderow, U., Monson, R. K., Montagnani, L., Moore, C. E., Moors, E., Moreaux, V., Moureaux, C., Munger, J. W., Nakai, T., Neirynck, J., Nesic, Z., Nicolini, G., Noormets, A., Northwood, M., Nosetto, M., Nouvellon, Y., Novick, K., Oechel, W., Olesen, J. E., Ourcival, J.-M., Papuga, S. A., Parmentier, F.-J., Paul-Limoges, E., Pavelka, M., Peichl, M., Pendall, E., Phillips, R. P., Pilegaard, K., Pirk, N., Posse, G., Powell, T., Prasse, H., Prober, S. M., Rambal, S., Rannik, Ü., Raz-Yaseef, N., Rebmann, C., Reed, D., Dios, V. R. D., Restrepo-Coupe, N., Reverter, B. R., Roland, M., Sabbatini, S., Sachs, T., Saleska, S. R., Sánchez-Cañete, E. P., Sanchez-Mejia, Z. M., Schmid, H. P., Schmidt, M., Schneider, K., Schrader, F., Schroder, I., Scott, R. L., Sedlák, P., Serrano-Ortíz, P., Shao, C., Shi, P., Shironya, I., Siebicke, L., Šigut, L., Silberstein, R., Sirca, C., Spano, D., Steinbrecher, R., Stevens, R. M., Sturtevant, C., Suyker, A., Tagesson, T., Takanashi, S., Tang, Y., Tapper, N., Thom, J., Tomassucci, M., Tuovinen, J.-P., Urbanski, S., Valentini, R., Van Der Molen, M., Van Gorsel, E., Van Huissteden, K., Varlagin, A., Verfaillie, J., Vesala, T., Vincke, C., Vitale, D., Vygodskaya, N., Walker, J. P., Walter-Shea, E., Wang, H., Weber, R., Westermann, S., Wille, C., Wofsy, S., Wohlfahrt, G., Wolf, S., Woodgate, W., Li, Y., Zampedri, R., Zhang, J., Zhou, G., Zona, D., Agarwal, D., Biraud, S., Torn, M., and Papale, D.: The FLUXNET2015 dataset and the ONEFlux processing pipeline for eddy covariance data, Scientific Data, 7, 225, <a href="https://doi.org/10.1038/s41597-020-0534-3" target="_blank">https://doi.org/10.1038/s41597-020-0534-3</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Peltola et al.(2021)Peltola, Aslan, Ibrom, Nemitz, Rannik, and Mammarella</label><mixed-citation>
      
Peltola, O., Aslan, T., Ibrom, A., Nemitz, E., Rannik, Ü., and Mammarella, I.: The high-frequency response correction
of eddy covariance fluxes – Part 1: An experimental approach and its interdependence with the time-lag estimation,
Atmos. Meas. Tech., 14, 5071–5088, <a href="https://doi.org/10.5194/amt-14-5071-2021" target="_blank">https://doi.org/10.5194/amt-14-5071-2021</a>, 2021. 
    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Polonik et al.(2019)Polonik, Chan, Billesbach, Burba, Li, Nottrott, Bogoev, Conrad, and
Biraud</label><mixed-citation>
       Polonik, P., Chan, W. S., Billesbach, D. P., Burba, G., Li, J., Nottrott, A.,
Bogoev, I., Conrad, B., and Biraud, S. C.: Comparison of gas analyzers for eddy covariance: Effects of analyzer type
and spectral corrections on fluxes, Agr. Forest Meteorol., 272–273, 128–142, <a href="https://doi.org/10.1016/j.agrformet.2019.02.010" target="_blank">https://doi.org/10.1016/j.agrformet.2019.02.010</a>,
2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>Rebmann et al.(2018)Rebmann, Aubinet, Schmid, Arriga, Aurela, Burba, Clement, De Ligne, Fratini, Gielen,
Grace, Graf, Gross, Haapanala, Herbst, Hörtnagl, Ibrom, Joly, Kljun, Kolle, Kowalski, Lindroth, Loustau, Mammarella,
Mauder, Merbold, Metzger, Mölder, Montagnani, Papale, Pavelka, Peichl, Roland, Serrano-Ortiz, Siebicke,
Steinbrecher, Tuovinen, Vesala, Wohlfahrt, and Franz</label><mixed-citation>
       Rebmann, C., Aubinet, M., Schmid, H.,
Arriga, N., Aurela, M., Burba, G., Clement, R., De Ligne, A., Fratini, G., Gielen, B., Grace, J., Graf, A., Gross, P.,
Haapanala, S., Herbst, M., Hörtnagl, L., Ibrom, A., Joly, L., Kljun, N., Kolle, O., Kowalski, A., Lindroth, A.,
Loustau, D., Mammarella, I., Mauder, M., Merbold, L., Metzger, S., Mölder, M., Montagnani, L., Papale, D.,
Pavelka, M., Peichl, M., Roland, M., Serrano-Ortiz, P., Siebicke, L., Steinbrecher, R., Tuovinen, J.-P., Vesala, T.,
Wohlfahrt, G., and Franz, D.: ICOS eddy covariance flux-station site setup: a review, Int. Agrophys., 32, 471–494,
<a href="https://doi.org/10.1515/intag-2017-0044" target="_blank">https://doi.org/10.1515/intag-2017-0044</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>Reichstein et al.(2005)Reichstein, Falge, Baldocchi, Papale, Aubinet, Berbigier, Bernhofer, Buchmann,
Gilmanov, Granier, Grunwald, Havrankova, Ilvesniemi, Janous, Knohl, Laurila, Lohila, Loustau, Matteucci, Meyers,
Miglietta, Ourcival, Pumpanen, Rambal, Rotenberg, Sanz, Tenhunen, Seufert, Vaccari, Vesala, Yakir, and
Valentini</label><mixed-citation>
       Reichstein, M., Falge, E., Baldocchi, D., Papale, D., Aubinet, M.,
Berbigier, P., Bernhofer, C., Buchmann, N., Gilmanov, T., Granier, A., Grunwald, T., Havrankova, K., Ilvesniemi, H.,
Janous, D., Knohl, A., Laurila, T., Lohila, A., Loustau, D., Matteucci, G., Meyers, T., Miglietta, F.,
Ourcival, J.-M., Pumpanen, J., Rambal, S., Rotenberg, E., Sanz, M., Tenhunen, J., Seufert, G., Vaccari, F.,
Vesala, T., Yakir, D., and Valentini, R.: On the separation of net ecosystem exchange into assimilation and ecosystem
respiration: review and improved algorithm, Glob. Change Biol., 11, 1424–1439,
<a href="https://doi.org/10.1111/j.1365-2486.2005.001002.x" target="_blank">https://doi.org/10.1111/j.1365-2486.2005.001002.x</a>, 2005.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>Reitz et al.(2022)Reitz, Graf, Schmidt, Ketzler, and Leuchner</label><mixed-citation>
       Reitz, O., Graf, A.,
Schmidt, M., Ketzler, G., and Leuchner, M.: Effects of Measurement Height and Low-Pass-Filtering
Corrections on Eddy-Covariance Flux Measurements Over a Forest Clearing with Complex Vegetation,
Bound.-Lay. Meteorol., 184, 277–299, <a href="https://doi.org/10.1007/s10546-022-00700-1" target="_blank">https://doi.org/10.1007/s10546-022-00700-1</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>Sabbatini and Papale(2017)</label><mixed-citation>
       Sabbatini, S. and Papale, D.: Instructions for turbulent flux measurements of CO2, energy and momentum, <a href="https://www.icos-etc.eu/icos/documents/instructions" target="_blank"/> (last access: 22 September 2026),  2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>Sabbatini et al.(2018)Sabbatini, Mammarella, Arriga, Fratini, Graf, Hörtnagl, Ibrom, Longdoz, Mauder, Merbold,
Metzger, Montagnani, Pitacco, Rebmann, Sedlák, Šigut, Vitale, and Papale</label><mixed-citation>
       Sabbatini, S.,
Mammarella, I., Arriga, N., Fratini, G., Graf, A., Hörtnagl, L., Ibrom, A., Longdoz, B., Mauder, M., Merbold, L.,
Metzger, S., Montagnani, L., Pitacco, A., Rebmann, C., Sedlák, P., Šigut, L., Vitale, D., and Papale, D.: Eddy
covariance raw data processing for CO<sub>2</sub> and energy fluxes calculation at ICOS ecosystem stations,
Int. Agrophys., 32, 495–515, <a href="https://doi.org/10.1515/intag-2017-0043" target="_blank">https://doi.org/10.1515/intag-2017-0043</a>, 2018.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>Smidt et al.(2025)Smidt, Wanner, Ibrom, Schmid, and Mauder</label><mixed-citation>
       Smidt, J., Wanner, L.,
Ibrom, A., Schmid, H., and Mauder, M.: High-frequency attenuation in eddy covariance measurements from the LI-7200
IRGA with various heating and filter configurations – a spectral correction approach, Agr. Forest Meteorol., 361,
110312, <a href="https://doi.org/10.1016/j.agrformet.2024.110312" target="_blank">https://doi.org/10.1016/j.agrformet.2024.110312</a>, 2025.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>Su et al.(2004)Su, Schmid, Grimmond, Vogel, and Oliphant</label><mixed-citation>
       Su, H.-B., Schmid, H. P.,
Grimmond, C. S. B., Vogel, C. S., and Oliphant, A. J.: Spectral Characteristics and Correction of Long-Term
Eddy-Covariance Measurements Over Two Mixed Hardwood Forests in Non-Flat Terrain,
Bound.-Lay. Meteorol., 110, 213–253, <a href="https://doi.org/10.1023/A:1026099523505" target="_blank">https://doi.org/10.1023/A:1026099523505</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>Vitale et al.(2020)Vitale, Fratini, Bilancia, Nicolini, Sabbatini, and Papale</label><mixed-citation>
      
Vitale, D., Fratini, G., Bilancia, M., Nicolini, G., Sabbatini, S., and Papale, D.: A robust data cleaning procedure
for eddy covariance flux measurements, Biogeosciences, 17, 1367–1391, <a href="https://doi.org/10.5194/bg-17-1367-2020" target="_blank">https://doi.org/10.5194/bg-17-1367-2020</a>,
2020. 
    </mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>Wintjen et al.(2020)Wintjen, Ammann, Schrader, and Brümmer</label><mixed-citation>
       Wintjen, P., Ammann, C.,
Schrader, F., and Brümmer, C.: Correcting high-frequency losses of reactive nitrogen flux measurements,
Atmos. Meas. Tech., 13, 2923–2948, <a href="https://doi.org/10.5194/amt-13-2923-2020" target="_blank">https://doi.org/10.5194/amt-13-2923-2020</a>, 2020. 
    </mixed-citation></ref-html>--></article>