<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">AMT</journal-id><journal-title-group>
    <journal-title>Atmospheric Measurement Techniques</journal-title>
    <abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1867-8548</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-19-6583-2026</article-id><title-group><article-title>Airborne performance assessment of the DLR MIRO MGA<sup>3</sup> quantum cascade laser spectrometer for fast N<sub>2</sub>O measurements</article-title><alt-title>N<sub>2</sub>O water correction</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Knez</surname><given-names>Leon</given-names></name>
          <email>leon.knez@dlr.de</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2 aff11">
          <name><surname>Eckl</surname><given-names>Maximilian</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Waldmann</surname><given-names>Paul</given-names></name>
          
        <ext-link>https://orcid.org/0009-0006-7894-3676</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Fiehn</surname><given-names>Alina</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-3376-4405</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Pühl</surname><given-names>Magdalena</given-names></name>
          
        <ext-link>https://orcid.org/0009-0001-2110-5173</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Aseev</surname><given-names>Oleg</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>Diskin</surname><given-names>Glenn S.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-3617-0269</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4">
          <name><surname>DiGangi</surname><given-names>Joshua P.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-6764-8624</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4 aff5">
          <name><surname>Choi</surname><given-names>Yonghoon</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-6529-4722</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff4 aff6">
          <name><surname>Miech</surname><given-names>Jason A.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-0356-5088</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7 aff8">
          <name><surname>Bennett</surname><given-names>Ryan</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7">
          <name><surname>Gatebe</surname><given-names>Charles K.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-9261-2239</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7 aff9">
          <name><surname>Dean-Day</surname><given-names>Jonathan M.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff7 aff9">
          <name><surname>Poudyal</surname><given-names>Rajesh</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff10">
          <name><surname>Lee</surname><given-names>Gangwoong</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff10">
          <name><surname>Kim</surname><given-names>Jeonghwan</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Roiger</surname><given-names>Anke</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Institut für Physik der Atmosphäre, Deutsches Zentrum für Luft- und Raumfahrt e.V. (DLR), 82234 Wessling, Germany</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>E.ON Energy Markets GmbH, Essen, Germany</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>MIRO Analytical AG, Wallisellen, Switzerland</institution>
        </aff>
        <aff id="aff4"><label>4</label><institution>NASA Langley Research Center, Hampton, VA, USA</institution>
        </aff>
        <aff id="aff5"><label>5</label><institution>Analytical Mechanics Associates, Hampton, VA, USA</institution>
        </aff>
        <aff id="aff6"><label>6</label><institution>Oak Ridge Associated Universities, Oak Ridge, TN, USA</institution>
        </aff>
        <aff id="aff7"><label>7</label><institution>NASA Ames Research Center, Moffett Field, CA, USA</institution>
        </aff>
        <aff id="aff8"><label>8</label><institution>National Suborbital Research Center, Grand Forks, ND, USA</institution>
        </aff>
        <aff id="aff9"><label>9</label><institution>Bay Area Environmental Research Institute, Moffett Field, CA, USA</institution>
        </aff>
        <aff id="aff10"><label>10</label><institution>Department of Environmental Science, Hankuk University of Foreign Studies, Seoul, Republic of South Korea</institution>
        </aff>
        <aff id="aff11"><label>a</label><institution>formerly at: Institut für Physik der Atmosphäre, Deutsches Zentrum für Luft- und Raumfahrt e.V. (DLR), 82234 Wessling, Germany</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Leon Knez (leon.knez@dlr.de)</corresp></author-notes><pub-date><day>19</day><month>October</month><year>2026</year></pub-date>
      
      <volume>19</volume>
      <issue>20</issue>
      <fpage>6583</fpage><lpage>6605</lpage>
      <history>
        <date date-type="received"><day>1</day><month>April</month><year>2026</year></date>
           <date date-type="rev-request"><day>10</day><month>April</month><year>2026</year></date>
           <date date-type="rev-recd"><day>14</day><month>September</month><year>2026</year></date>
           <date date-type="accepted"><day>22</day><month>September</month><year>2026</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2026 Leon Knez et al.</copyright-statement>
        <copyright-year>2026</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026.html">This article is available from https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026.html</self-uri><self-uri xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d2e327">Nitrous oxide (N<sub>2</sub>O) is the most dominant precursor of ozone-depleting substances and the third  most important anthropogenic greenhouse gas, with agriculture contributing the largest share of emissions (56 %). Over the past two decades, airborne in-situ measurements have become increasingly important for studying emission and transport of N<sub>2</sub>O in the atmosphere, also driven by the development of more precise and simultaneously faster Quantum Cascade Laser (QCL)-based spectrometers.</p>

      <p id="d2e348">However, many QCL-based spectrometers exhibit sensitivities to environmental and flight-related parameters that can vary rapidly (<inline-formula><mml:math id="M6" display="inline"><mml:mo lspace="0mm">≤</mml:mo></mml:math></inline-formula> 1 s), such as static or cabin pressure and aircraft roll and pitch angles. The impact of changing ambient water vapor is particularly critical due to both dilution and quantum-mechanical effects. Because the variability of N<sub>2</sub>O in the lower troposphere  is often very small (<inline-formula><mml:math id="M8" display="inline"><mml:mo lspace="0mm">&lt;</mml:mo></mml:math></inline-formula> 1 ppb) relative to its high background (<inline-formula><mml:math id="M9" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 338 ppb), even minor variations in these parameters can significantly affect data quality and must be corrected. Although many instruments can resolve such small concentration changes, their typical temporal resolution of <inline-formula><mml:math id="M10" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> Hz may limit the application of advanced measurement techniques such as eddy covariance on fast-moving aircraft.</p>

      <p id="d2e388">Here, we present and evaluate a new instrument setup for precise (<inline-formula><mml:math id="M11" display="inline"><mml:mo lspace="0mm">&lt;</mml:mo></mml:math></inline-formula> 0.2 ppb) and high-frequency (<inline-formula><mml:math id="M12" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz) airborne in-situ N<sub>2</sub>O measurements in altitudes up to <inline-formula><mml:math id="M14" display="inline"><mml:mn mathvariant="normal">4500</mml:mn></mml:math></inline-formula> m based on a MIRO MGA<sup>3</sup> QCL spectrometer (MIRO Analytical AG). The instrument was successfully deployed during two airborne science missions, namely onboard the unpressurized DLR Cessna during the Greenhouse Gas Monitoring (GHGMon) campaign in 2023 in the Netherlands, as well as onboard the NASA DC-8 during the Airborne and Satellite Investigation of Asian Air Quality (ASIA-AQ) campaign in 2024. Specifically, we evaluate and compare different water vapor correction approaches using ASIA-AQ data sampled within the tropical boundary layer over South Korea, the Philippines, Thailand and Taiwan, which partly were characterized by specifically high ambient humidity (up to 30 000 ppm H<sub>2</sub>O). The water vapor correction methods include an empirical approach that relies on both native and corrected MIRO in-flight water vapor measurements, as well as an approach by an updated version of the MIRO specific fitting software. Comparison with N<sub>2</sub>O measurements from a well-established instrument onboard the NASA DC-8 shows agreement within combined measurement uncertainties for all tested water vapor correction approaches, albeit special caution is needed for humidities larger than 15 000 ppm. The new water vapor corrected data shows a 42 % better precision than with original default settings of the instrument. We further show that the instrument setup is insensitive to flight parameter changes such as roll and pitch angle of the aircraft, and allows for stable measurements even under challenging conditions such as in the turbulent boundary layer.</p>

      <p id="d2e449">This instrument setup enables improved characterization of N<sub>2</sub>O emissions and sources from the agricultural sector, which is particularly relevant for tropical regions with strong agricultural activity and high humidity, where observational data remain scarce.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d2e470">Nitrous Oxide (N<sub>2</sub>O) is, after carbon dioxide (CO<sub>2</sub>) and methane (CH<sub>4</sub>), the third most important anthropogenic greenhouse gas (GHG) <xref ref-type="bibr" rid="bib1.bibx25" id="paren.1"/> and the dominant precursor of ozone (O<sub>3</sub>)-depleting substances in the stratosphere <xref ref-type="bibr" rid="bib1.bibx32" id="paren.2"/>. It has an atmospheric lifetime exceeding <inline-formula><mml:math id="M23" display="inline"><mml:mrow><mml:mn mathvariant="normal">100</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/></mml:mrow></mml:math></inline-formula>years <xref ref-type="bibr" rid="bib1.bibx28 bib1.bibx30 bib1.bibx29 bib1.bibx25" id="paren.3"/>. Since the preindustrial era, its atmospheric mole fraction has increased from approximately <inline-formula><mml:math id="M24" display="inline"><mml:mn mathvariant="normal">270</mml:mn></mml:math></inline-formula> ppb in 1750 to <inline-formula><mml:math id="M25" display="inline"><mml:mn mathvariant="normal">336</mml:mn></mml:math></inline-formula> ppb in 2022 <xref ref-type="bibr" rid="bib1.bibx42 bib1.bibx24" id="paren.4"/> corresponding to a sustained rise with a mean annual growth rate of <inline-formula><mml:math id="M26" display="inline"><mml:mn mathvariant="normal">0.96</mml:mn></mml:math></inline-formula> ppb yr<sup>−1</sup> during the decade from 2010 to 2019 <xref ref-type="bibr" rid="bib1.bibx42" id="paren.5"/>.</p>
      <p id="d2e568">N<sub>2</sub>O is emitted to the atmosphere from both natural (<inline-formula><mml:math id="M29" display="inline"><mml:mn mathvariant="normal">65</mml:mn></mml:math></inline-formula> % of total net emissions) and anthropogenic (35 %) sources <xref ref-type="bibr" rid="bib1.bibx42" id="paren.6"/>. Among anthropogenic sources, agriculture dominates, accounting for 56 % of total net emissions. These emissions primarily arise from the microbial processes of nitrification and denitrification, through which organic and synthetic fertilizers are partially converted to N<sub>2</sub>O, as well as from direct nitrogen (N) inputs to soils <xref ref-type="bibr" rid="bib1.bibx42 bib1.bibx40" id="paren.7"/>. Additional significant anthropogenic contributions originate from other direct emissions (<inline-formula><mml:math id="M31" display="inline"><mml:mn mathvariant="normal">32</mml:mn></mml:math></inline-formula> %), including industry, fossil fuel use, and biomass burning <xref ref-type="bibr" rid="bib1.bibx42" id="paren.8"/>. The growth rate is expected to increase even further in the future due to the growing demand for food, energy and industrial processes associated with continued population growth <xref ref-type="bibr" rid="bib1.bibx42 bib1.bibx40 bib1.bibx33" id="paren.9"/>.</p>
      <p id="d2e616">This makes N<sub>2</sub>O a key target for future mitigation policy <xref ref-type="bibr" rid="bib1.bibx17" id="paren.10"/>. To meet the goals of the Paris Agreement <xref ref-type="bibr" rid="bib1.bibx43" id="paren.11"/>, limiting global warming to <inline-formula><mml:math id="M33" display="inline"><mml:mn mathvariant="normal">2</mml:mn></mml:math></inline-formula> °C requires a reduction in N<sub>2</sub>O emissions of <inline-formula><mml:math id="M35" display="inline"><mml:mn mathvariant="normal">11</mml:mn></mml:math></inline-formula> % by 2050 and as much as <inline-formula><mml:math id="M36" display="inline"><mml:mn mathvariant="normal">22</mml:mn></mml:math></inline-formula> % to achieve the <inline-formula><mml:math id="M37" display="inline"><mml:mn mathvariant="normal">1.5</mml:mn></mml:math></inline-formula> °C limit <xref ref-type="bibr" rid="bib1.bibx35 bib1.bibx42" id="paren.12"/>. However, alarmingly, even the worst case Representative Concentration Pathways (RCPs) and Shared Socioeconomic Pathways (SSPs) underestimate the global mean N<sub>2</sub>O mole fractions observed in the atmosphere by roughly 2–3 ppb in 2020 <xref ref-type="bibr" rid="bib1.bibx42" id="paren.13"/>. Current models sometimes lack adequate representation for N<sub>2</sub>O emission factors, for example, for the amount of N soil input or freeze-thaw cycles, which results from a lack of data and measurements for specific regions <xref ref-type="bibr" rid="bib1.bibx9 bib1.bibx41" id="paren.14"/>.</p>
      <p id="d2e700">Developing efficient mitigation strategies requires precise quantification of emissions from dominant source sectors and a robust understanding of the underlying processes. N<sub>2</sub>O emissions can be estimated using a range of approaches, commonly classified as Bottom Up (BU) and Top Down (TD) methods <xref ref-type="bibr" rid="bib1.bibx42 bib1.bibx36 bib1.bibx3 bib1.bibx8" id="paren.15"/>. TD approaches include satellite observations, which offer global coverage but are not yet operational for N<sub>2</sub>O <xref ref-type="bibr" rid="bib1.bibx19" id="paren.16"/>. At smaller scales, chamber and tower measurements provide insights at spatial extents of <inline-formula><mml:math id="M42" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> m<sup>2</sup> and up to 10 km<sup>2</sup>, respectively, but are inherently limited to fixed locations <xref ref-type="bibr" rid="bib1.bibx4 bib1.bibx31 bib1.bibx26" id="paren.17"/>. In contrast, airborne measurements can cover regional scales on the order of 1–100 km and help bridge spatial gaps in the data from chamber and tall tower measurements <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx26" id="paren.18"/>. Additionally, in combination with eddy covariance techniques, they further enable improved quantification of emissions from specific sources, which is particularly valuable for the complex and heterogeneous agricultural sector <xref ref-type="bibr" rid="bib1.bibx44 bib1.bibx40" id="paren.19"/>.</p>
      <p id="d2e763">In the case of N<sub>2</sub>O, previously used instruments for high precision N<sub>2</sub>O measurements, such as the well established Gas Chromatographs (GCs) or Fourier transform infrared (FTIR) spectrometers with temporal resolutions in the order of <inline-formula><mml:math id="M47" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> min, are being replaced due to the improvement of laser-based measurement techniques and the growing commercial availability of laser spectrometers, allowing for precise (<inline-formula><mml:math id="M48" display="inline"><mml:mo lspace="0mm">&lt;</mml:mo></mml:math></inline-formula> 1 ppb) and simultaneously faster measurements (<inline-formula><mml:math id="M49" display="inline"><mml:mo lspace="0mm">∼</mml:mo></mml:math></inline-formula> 1 Hz) <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx21 bib1.bibx31 bib1.bibx23" id="paren.20"/>. Particularly, the development of Continuous Wave (CW) Quantum Cascade Lasers (QCLs) working at room temperature opened new possibilities for fast, continuous, more sensitive and more feasible mid-Infrared (IR) absorption spectroscopy <xref ref-type="bibr" rid="bib1.bibx22 bib1.bibx2" id="paren.21"/> making overly complicated and expensive cooling systems on an aircraft redundant.</p>
      <p id="d2e812">Several airborne N<sub>2</sub>O in-situ studies using QCLs or other laser-based techniques have already been successfully conducted over the last two decades <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx11 bib1.bibx15 bib1.bibx20 bib1.bibx14 bib1.bibx27 bib1.bibx46 bib1.bibx38" id="paren.22"/>. However, many of these studies report a temporal resolution of <inline-formula><mml:math id="M51" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> Hz or less, which can be too slow for N<sub>2</sub>O eddy covariance measurements on a fast aircraft. Furthermore, airborne measurements still bear more challenges than ground based measurements. During a flight, several parameters may vary considerably, thereby affecting measurement performance. <xref ref-type="bibr" rid="bib1.bibx27" id="text.23"/>, <xref ref-type="bibr" rid="bib1.bibx14" id="text.24"/> and <xref ref-type="bibr" rid="bib1.bibx20" id="text.25"/>, for example, report dependencies on changes in cabin pressure, roll and pitch angles of the aircraft, and also water vapor (H<sub>2</sub>O), which resulted in deviations of some ppb in N<sub>2</sub>O. This can be difficult for the precise measurement of small N<sub>2</sub>O variability (<inline-formula><mml:math id="M56" display="inline"><mml:mo lspace="0mm">&lt;</mml:mo></mml:math></inline-formula> 1 ppb) and could be particularly problematic for flights in highly humid regions. Therefore, possible dependencies must be known and addressed by empirical corrections and specific calibration procedures. Furthermore, the space for the instrument setup onboard the aircraft is usually limited, resulting, e.g., in fewer possibilities to carry calibration gases which can impact the calibration procedure and, consequently, data quality.</p>
      <p id="d2e887">Here, we present the performance assessment and evaluation of the DLR-MIRO system, a fast (<inline-formula><mml:math id="M57" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz sampling frequency) airborne measurement setup specifically tuned for N<sub>2</sub>O measurements with an in-flight precision of <inline-formula><mml:math id="M59" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 0.18 ppb enabling airborne eddy covariance measurements for N<sub>2</sub>O <xref ref-type="bibr" rid="bib1.bibx44" id="paren.26"/>. The core instrument of the setup is a commercially available Quantum Cascade Laser Absorption Spectrometer (QCLAS), namely a Multicompound Gas Analyzer (MGA<sup>3</sup>), from the Swiss company MIRO Analytical AG. We assess the performance of the instrument during in-flight operation onboard two different research aircraft, a Cessna 208-B Grand Caravan operated by the German Aerospace Center (DLR) with an unpressurized cabin and NASA's Douglas DC-8 with a pressurized cabin. The Cessna was deployed on the Greenhouse Gas Monitoring (GHGMon) campaign in the Netherlands in June 2023. The DC-8 was deployed on the NASA Airborne and Satellite Investigation of Asian Air Quality (ASIA-AQ) campaign in February and March 2024 over the Philippines, South Korea, Taiwan and Thailand. Flights were conducted in humid regions using repeated country-specific flight patterns and vertical profiles. Due to the high variability of H<sub>2</sub>O (0 %–3 %) in tropical environments, we focus on its impact on retrieved N<sub>2</sub>O mole fractions. This is particularly important because the original fitting software version v1 did not account for H<sub>2</sub>O effects, including both dilution and quantum-mechanical processes such as line broadening. To address this, we derive an empirical water vapor correction based on dedicated laboratory experiments. The results obtained with this correction are compared with those from an updated MIRO fitting software v2, which incorporates a water vapor correction derived from the same experimental dataset from the laboratory. We evaluate and discuss the advantages and limitations of both approaches, including an assessment of the MGA<sup>3</sup> H<sub>2</sub>O measurements themselves and the importance for their overall accuracy.</p>
      <p id="d2e980">This study is structured as follows: in Sect. <xref ref-type="sec" rid="Ch1.S2"/>, we present the specifications of our MGA<sup>3</sup> instrument and the airborne setup, which was identical for both the NASA DC-8 and the DLR Cessna Grand Caravan. We describe the calibration procedure, the basics of the retrieval software v1 of the MGA<sup>3</sup> and elaborate on the relevant parameters for fitting the measured spectra, such as the width of absorption line (<inline-formula><mml:math id="M69" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>). In Sect. <xref ref-type="sec" rid="Ch1.S3"/>, we first provide an overview of the different water vapor correction approaches applied in this study and describe the laboratory experiment used to derive corresponding parameters for the correction equation. In the next step, we compare the MGA<sup>3</sup> H<sub>2</sub>O-measurements to NASA's established Diode Laser Hygrometer (DLH) H<sub>2</sub>O-measurements to derive an even more precise water vapor correction. We compare our empirical water vapor correction approaches with a new software version v2 that already implements a water vapor correction based on the same conducted laboratory experiment. We also compare our H<sub>2</sub>O-corrected N<sub>2</sub>O-measurements with N<sub>2</sub>O-measurements conducted by NASA's established Differential Absorption Carbon monOxide Measurements (DACOM) spectrometer <xref ref-type="bibr" rid="bib1.bibx37" id="paren.27"/>, a Tunable Diode Laser Absorption Spectrometer (TDLAS) which was also onboard the DC-8 during the ASIA-AQ campaign. In Sect. <xref ref-type="sec" rid="Ch1.S4"/>, we assess the stability of the MGA<sup>3</sup> under ground conditions by calculating its Allan precision and investigate potential dependencies of N<sub>2</sub>O-measurements on cabin pressure and roll and pitch angles of the aircraft during flights. In Sect. <xref ref-type="sec" rid="Ch1.S5"/>, we present selected flight data from the ASIA-AQ campaign corrected using the different water vapor correction approaches. Finally, we show examples of ambient N<sub>2</sub>O measurements from GHGMon and ASIA-AQ to demonstrate the capabilities of the MGA<sup>3</sup> airborne setup under in-flight conditions.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Operational Design</title>
      <p id="d2e1120">At both the GHGMon and the ASIA-AQ campaign, we operated the same DLR-MIRO setup with a commercially available QCLAS, namely the Multicompound Gas Analyzer (MGA<sup>3</sup>) by the MIRO Analytical AG from Switzerland, as its core instrument. The setup is specifically optimized for N<sub>2</sub>O measurements with the capability for the eddy covariance method and up to altitudes of approximately <inline-formula><mml:math id="M82" display="inline"><mml:mn mathvariant="normal">5.5</mml:mn></mml:math></inline-formula> km. In the following sections we first describe the specifications of the MGA<sup>3</sup>, its integration into the airborne instrument setup, and the data calibration procedure. To provide a better context for our water vapor correction approach, Sect. <xref ref-type="sec" rid="Ch1.S2.SS4"/> and <xref ref-type="sec" rid="Ch1.S2.SS5"/> outlines the basic theory of spectral fitting and introduces the most important parameters for the water vapor correction as well as the method used by the MGA<sup>3</sup> mole fraction retrieval software.</p>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Instrument specifications of the MIRO MGA<sup>3</sup></title>
      <p id="d2e1188">The MGA<sup>3</sup> is a two-laser (Alpes Lasers; St. Blaise, Switzerland) QCLAS and is able to measure three species at once – N<sub>2</sub>O, CH<sub>4</sub>, and CO – in addition to H<sub>2</sub>O, all within one Herriot measurement cell with a volume of <inline-formula><mml:math id="M90" display="inline"><mml:mn mathvariant="normal">0.44</mml:mn></mml:math></inline-formula> L and an optical path length of <inline-formula><mml:math id="M91" display="inline"><mml:mn mathvariant="normal">76</mml:mn></mml:math></inline-formula> m. The wavenumbers scanned by the first laser (laser 1) are 2191.38–<inline-formula><mml:math id="M92" display="inline"><mml:mn mathvariant="normal">2189.85</mml:mn></mml:math></inline-formula> cm<sup>−1</sup> and the wavenumbers of the second laser (laser 2) are 1282.50–1281.01 cm<sup>−1</sup> (see Table <xref ref-type="table" rid="T1"/>). The MGA<sup>3</sup> is specifically optimized for N<sub>2</sub>O measurements by the selection of the spectral absorption lines and the settings defined by the manufacturer. The maximum time resolution of the data retrieval of the instrument is <inline-formula><mml:math id="M97" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz.</p>

<table-wrap id="T1"><label>Table 1</label><caption><p id="d2e1304">Wavenumbers and HITRAN isotopologue numbers of the absorption lines of the target species of laser 1 and laser 2 of the MGA<sup>3</sup>.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Wavenumber</oasis:entry>
         <oasis:entry colname="col3">Isotopologue</oasis:entry>
         <oasis:entry colname="col4">Laser</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">cm<sup>−1</sup></oasis:entry>
         <oasis:entry colname="col3">number</oasis:entry>
         <oasis:entry colname="col4"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">N<sub>2</sub>O</oasis:entry>
         <oasis:entry colname="col2">2190.35</oasis:entry>
         <oasis:entry colname="col3">446</oasis:entry>
         <oasis:entry colname="col4">laser 1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CO</oasis:entry>
         <oasis:entry colname="col2">2190.02</oasis:entry>
         <oasis:entry colname="col3">26</oasis:entry>
         <oasis:entry colname="col4">laser 1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">CH<sub>4</sub></oasis:entry>
         <oasis:entry colname="col2">1281.61</oasis:entry>
         <oasis:entry colname="col3">211</oasis:entry>
         <oasis:entry colname="col4">laser 2</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">H<sub>2</sub>O</oasis:entry>
         <oasis:entry colname="col2">1281.53</oasis:entry>
         <oasis:entry colname="col3">162</oasis:entry>
         <oasis:entry colname="col4">laser 2</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e1460">The QCLs are driven by an intermittent Continuous Wave (iCW) driving scheme with pulse durations of 10–100 s and an overall period of about 0.5–1 ms. The temperatures of the lasers are held constant at around <inline-formula><mml:math id="M103" display="inline"><mml:mn mathvariant="normal">32</mml:mn></mml:math></inline-formula> °C (laser 1) and <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> °C (laser 2) by ThermoElectric Coolers (TECs). For further general information on the MGAs by MIRO Analytical, please find the paper of <xref ref-type="bibr" rid="bib1.bibx16" id="text.28"/>.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Airborne setup</title>
      <p id="d2e1491">For the complete functional airborne setup, the MGA<sup>3</sup> requires additional structural components and peripheral devices. First, a liquid chiller (Thermorack401, Solid State Cooling Systems, Wappingers Falls, USA) provides the heat reservoir for the optical compartment of the MGA<sup>3</sup> and the TECs cooling the lasers within the compartment (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS1"/>) as can be seen in Fig. <xref ref-type="fig" rid="F1"/>. The MGA<sup>3</sup> has two inlets, one sample air inlet and one calibration gas inlet. When measuring sample air from outside the DC-8 aircraft, the air is first drawn through a rear-facing 62° trapezoid inlet at the hull of the aircraft and then directed through an about <inline-formula><mml:math id="M108" display="inline"><mml:mn mathvariant="normal">6.5</mml:mn></mml:math></inline-formula> m long PTFE tube with a diameter of <inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> in. to a <inline-formula><mml:math id="M110" display="inline"><mml:mn mathvariant="normal">2</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M111" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m PTFE-membrane particle filter (filter membrane: R2PJ047 Pall, filter holder: PA1235 Pall). For the Cessna, the PTFE tube was approximately <inline-formula><mml:math id="M112" display="inline"><mml:mn mathvariant="normal">5.5</mml:mn></mml:math></inline-formula> m long and installed through the wing of the aircraft and through its attached wingpod. After filtering the sample air passes a Mass Flow Meter (MFM) (F-102E, Bronkhorst) before it enters the MGA<sup>3</sup> through its sample air inlet. A scroll pump (IS500C, Anest Iwata) connected to the outlet of the MGA<sup>3</sup> is used for creating a vacuum which draws the sample air in. The pump was specifically selected to generate the highest possible mass flow without exceeding the Cessna's power constraints. In this instrument setup with the long inlet tubing, the pump generated a mass flow of 12.5–13.8 slpm. The pump motor is additionally cooled with a standard external fan to prevent overheating. Given the MGA<sup>3</sup> cell volume of <inline-formula><mml:math id="M116" display="inline"><mml:mn mathvariant="normal">0.44</mml:mn></mml:math></inline-formula> L and a cell pressure of <inline-formula><mml:math id="M117" display="inline"><mml:mn mathvariant="normal">70</mml:mn></mml:math></inline-formula> hPa this corresponds to an effective sampling frequency of 6.85–7.57 Hz, assuming plug flow. To achieve higher mass flows, and therefore higher effective sampling frequencies, we recommend minimizing the distance between the aircraft inlet and the instrument.</p>

      <fig id="F1" specific-use="star"><label>Figure 1</label><caption><p id="d2e1611">Setup of the instrumentation for both the 2023 GHGmon campaign and the 2024 ASIA-AQ campaign. The left side shows a scheme of the setup including the calibration setup within the orange box. The right side contains a photo of the setup onboard NASA's DC-8 during ASIA-AQ.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f01.png"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Calibration of data and response time</title>
      <p id="d2e1629">In this section, we describe the calibration procedure applied to our data to account for drifts and potential changes in the sensitivity of the MGA<sup>3</sup> and determine the response time of the system. To avoid drift and sensitivity effects of GHG measurements and to improve the accuracy of the retrieved mole fractions, the instrument needs to be regularly calibrated in-flight using a two-point calibration. For this, the MGA<sup>3</sup> switches an internal valve and then draws air not from the sample air inlet but from the calibration gas inlet which is connected to an in-flight calibration system (see Fig. <xref ref-type="fig" rid="F1"/>, orange box). As can be seen from the measurements in Fig. <xref ref-type="fig" rid="F2"/>, as an example from ASIA-AQ, every <inline-formula><mml:math id="M120" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> min two calibration gases are drawn, a low-standard calibration gas <inline-formula><mml:math id="M121" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> and a high-standard calibration gas <inline-formula><mml:math id="M122" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula>, each for <inline-formula><mml:math id="M123" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> s in sequence. Two solenoid valves are operated directly from the MGA<sup>3</sup> software and they control which of the two gases is currently being used. The red areas show the <inline-formula><mml:math id="M125" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M126" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> standards, and the grey areas show when cabin air is sampled through the overflow while switching the main MGA<sup>3</sup> valve from the sample air inlet to the calibration gas inlet. When the main valve of the MGA<sup>3</sup> switches to cabin air in the first gray area or when  the solenoid valves switch to the calibration gases, the initial high pressure coming from the cabin or the cylinders results in a feedback behavior leading to a time of 1–2 s for the cell to be completely flooded by the cabin air or the calibration gases. When switching the valves back to the cabin air in the second grey area in Fig. <xref ref-type="fig" rid="F2"/> or back to ambient sampling air after the second red area, this effect does not occur. With these two cases we determine our response time of 0.1–0.2 s which confirms our effective sampling frequency of approximately <inline-formula><mml:math id="M129" display="inline"><mml:mn mathvariant="normal">7</mml:mn></mml:math></inline-formula> Hz determined with the mass flow through the cell in Sect. <xref ref-type="sec" rid="Ch1.S2.SS2"/>. More details on the calibration times will be shown in Sect. <xref ref-type="sec" rid="Ch1.S4.SS1"/>. The Mass Flow Controller (MFC) (F-201CV, Bronkhorst) behind the solenoid valves is set to a higher flow than the instrument consumes (15 slpm) and any excess flow of the calibration gases in front of the MGA<sup>3</sup> inlet is released to the cabin via an overflow. All in-flight calibration gas standards for N<sub>2</sub>O are chosen to be close to the atmospheric background mole fractions and were themselves calibrated on the ground against NOAA-standards (traceable to the NOAA-N2O_X2006A reference scale). In Table <xref ref-type="table" rid="T2"/>, the N<sub>2</sub>O mole fractions of the two different high and low standards used during the GHGMon campaign and the three different high and low standards used during the ASIA-AQ campaign are shown. High and low standards were chosen to have a difference of <inline-formula><mml:math id="M133" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula>-<inline-formula><mml:math id="M134" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> ppb to be able to cover the small variability in N<sub>2</sub>O caused by agricultural emissions.</p>

      <fig id="F2"><label>Figure 2</label><caption><p id="d2e1794">Example of an in-flight two-point calibration from the ASIA-AQ campaign. When a calibration sequence is activated first an internal valve of the MGA<sup>3</sup> switches from the sample air inlet to the calibration gas inlet. Then, during the first time span (gray area), cabin air is drawn in via the overflow of the calibration system. Shortly after the solenoid valve for the low standard calibration gas <inline-formula><mml:math id="M137" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> is activated for about <inline-formula><mml:math id="M138" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> s allowing the gas to be drawn in by the MGA<sup>3</sup> (first red area). Then the solenoid valve closes and cabin air is shortly drawn again (second gray area) until the second solenoid valve activates for the high standard calibration gas <inline-formula><mml:math id="M140" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> (second red area). In total the calibration process lasts for about <inline-formula><mml:math id="M141" display="inline"><mml:mn mathvariant="normal">40</mml:mn></mml:math></inline-formula> s. The black dots are the mean values <inline-formula><mml:math id="M142" display="inline"><mml:mrow><mml:msub><mml:mi>L</mml:mi><mml:mi mathvariant="normal">meas</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mi mathvariant="normal">meas</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of <inline-formula><mml:math id="M144" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M145" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> with their respective errors, which are then used for the calibration to relate to the known reference values of the calibration gases.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f02.png"/>

        </fig>

<table-wrap id="T2"><label>Table 2</label><caption><p id="d2e1889">Mole fraction values of each high and low standard gas pair for the GHGMon and ASIA-AQ campaign.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">N<sub>2</sub>O low</oasis:entry>
         <oasis:entry colname="col3">N<sub>2</sub>O high</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">standard (ppb)</oasis:entry>
         <oasis:entry colname="col3">standard (ppb)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">GHGMon 1</oasis:entry>
         <oasis:entry colname="col2">344.85</oasis:entry>
         <oasis:entry colname="col3">347.35</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">GHGMon 2</oasis:entry>
         <oasis:entry colname="col2">344.63</oasis:entry>
         <oasis:entry colname="col3">346.65</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">ASIA-AQ 1</oasis:entry>
         <oasis:entry colname="col2">333.99</oasis:entry>
         <oasis:entry colname="col3">342.23</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">ASIA-AQ 2</oasis:entry>
         <oasis:entry colname="col2">330.47</oasis:entry>
         <oasis:entry colname="col3">340.65</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">ASIA-AQ 3</oasis:entry>
         <oasis:entry colname="col2">331.32</oasis:entry>
         <oasis:entry colname="col3">339.03</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e2010">To calculate the calibrated time series <inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">cal</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> out of a measured raw data time series <inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">raw</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> that is provided by the MGA<sup>3</sup>, we first calculate a scale factor <inline-formula><mml:math id="M151" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and an offset <inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for each calibration cycle <inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>, …, <inline-formula><mml:math id="M154" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> for all <inline-formula><mml:math id="M155" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>∈</mml:mo><mml:mi mathvariant="double-struck">N</mml:mi></mml:mrow></mml:math></inline-formula> cycles, according to <xref ref-type="bibr" rid="bib1.bibx27" id="text.29"/> with:

            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M156" display="block"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mi mathvariant="normal">true</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>L</mml:mi><mml:mi mathvariant="normal">true</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mrow><mml:mi mathvariant="normal">meas</mml:mi><mml:mo>,</mml:mo><mml:mi>n</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>L</mml:mi><mml:mrow><mml:mi mathvariant="normal">meas</mml:mi><mml:mo>,</mml:mo><mml:mi>n</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo><mml:mspace linebreak="nobreak" width="1em"/><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>N</mml:mi><mml:mo>;</mml:mo><mml:mspace linebreak="nobreak" width="1em"/><mml:mi>N</mml:mi><mml:mo>∈</mml:mo><mml:mi mathvariant="double-struck">N</mml:mi></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e2202">
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M157" display="block"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>H</mml:mi><mml:mi mathvariant="normal">true</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>m</mml:mi><mml:mi>n</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>H</mml:mi><mml:mi mathvariant="normal">meas</mml:mi></mml:msub><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          Here <inline-formula><mml:math id="M158" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mrow><mml:mi mathvariant="normal">meas</mml:mi><mml:mo>,</mml:mo><mml:mi>n</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:msub><mml:mi>L</mml:mi><mml:mrow><mml:mi mathvariant="normal">meas</mml:mi><mml:mo>,</mml:mo><mml:mi>n</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> are the means of the measured values for the high and low standards <inline-formula><mml:math id="M160" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M161" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> as shown for one calibration cycle <inline-formula><mml:math id="M162" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> in Fig. <xref ref-type="fig" rid="F2"/>. <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mi mathvariant="normal">true</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:msub><mml:mi>L</mml:mi><mml:mi mathvariant="normal">true</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> represent their known true mole fractions in Table <xref ref-type="table" rid="T2"/>. We interpolate the scale factors <inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and offsets <inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> between every calibration cycle for every time point <inline-formula><mml:math id="M167" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> in the measured time series <inline-formula><mml:math id="M168" display="inline"><mml:mrow><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">raw</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and get the continuous scale factor <inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and offset <inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:mi>d</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> which lead us to the calibrated values <inline-formula><mml:math id="M171" display="inline"><mml:mrow><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">cal</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>:

            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M172" display="block"><mml:mrow><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">cal</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mi>m</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>⋅</mml:mo><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">raw</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mi>d</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          For our H<sub>2</sub>O measurements, we only use a zeroing procedure, since both <inline-formula><mml:math id="M174" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M175" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> standards are dry and should not contain any H<sub>2</sub>O. Here, we calculate the difference <inline-formula><mml:math id="M177" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> between the mean <inline-formula><mml:math id="M178" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mrow><mml:mi mathvariant="normal">meas</mml:mi><mml:mo>,</mml:mo><mml:mi>n</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> of a measured calibration cycle of only one of the two cylinders and its assumed actual value <inline-formula><mml:math id="M179" display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">true</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula>. We obtain the calibrated value <inline-formula><mml:math id="M180" display="inline"><mml:mrow><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">cal</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> by interpolating <inline-formula><mml:math id="M181" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for every <inline-formula><mml:math id="M182" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> to <inline-formula><mml:math id="M183" display="inline"><mml:mrow><mml:mi>d</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>:

                <disp-formula specific-use="gather" content-type="numbered"><mml:math id="M184" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E4"><mml:mtd><mml:mtext>4</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>d</mml:mi><mml:mi>n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mi mathvariant="normal">true</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mrow><mml:mi mathvariant="normal">meas</mml:mi><mml:mo>,</mml:mo><mml:mi>n</mml:mi></mml:mrow></mml:msub><mml:mo>,</mml:mo><mml:mspace linebreak="nobreak" width="1em"/><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>N</mml:mi><mml:mo>;</mml:mo><mml:mspace width="1em" linebreak="nobreak"/><mml:mi>N</mml:mi><mml:mo>∈</mml:mo><mml:mi mathvariant="double-struck">N</mml:mi></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E5"><mml:mtd><mml:mtext>5</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">cal</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mi mathvariant="normal">raw</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mi>d</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>
      <p id="d2e2740">For the uncertainty of our cylinders we use the standard error for every mean calculated from the <inline-formula><mml:math id="M185" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M186" display="inline"><mml:mi>H</mml:mi></mml:math></inline-formula> standards in the calibration cycles, resulting in uncertainties below <inline-formula><mml:math id="M187" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> ppb. Experience from GHGMon showed that the respective differences between the standards of about <inline-formula><mml:math id="M188" display="inline"><mml:mn mathvariant="normal">3</mml:mn></mml:math></inline-formula> ppb in N<sub>2</sub>O were too small causing issues while calibrating the data, especially with the error calculation for the calibration procedure. Based on this and the later experience from ASIA-AQ flights, we recommend that the differences between the high and low standards including the errors of the cylinder values should be at least two orders of magnitude higher than the precision of the MGA<sup>3</sup>.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><title>MGA<sup>3</sup> mole fraction retrieval software and versions</title>
      <p id="d2e2808">In this section, we explain how the MGA<sup>3</sup> software retrieves the mole fraction values <inline-formula><mml:math id="M193" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> from its measurements. The lasers of the MGA<sup>3</sup> emit light in a wavenumber range close to the absorption lines of the target species such as N<sub>2</sub>O. The laser beam is directed into the measurement cell where the target sample air is located. There, the intensity <inline-formula><mml:math id="M196" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of the laser beam weakens through absorption by the sample air. After the laser beam exits the cell, it illuminates a detector which measures the intensity <inline-formula><mml:math id="M197" display="inline"><mml:mi>I</mml:mi></mml:math></inline-formula> along the wavelengths, i.e. the absorption spectrum and therefore the absorption line profile of the N<sub>2</sub>O. Each measured spectrum is then provided as the transmittance <inline-formula><mml:math id="M199" display="inline"><mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> by the MGA<sup>3</sup>. The measured absorption line profile can either be fitted online while measuring or later on at any time with the MGA-ReFit software. The lines are fitted by minimizing the sum of least-squares using the Beer-Lambert law, which in this case is based on a Voigt profile:

            <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M201" display="block"><mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>I</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mi>exp⁡</mml:mi><mml:mfenced open="(" close=")"><mml:mrow><mml:mo>-</mml:mo><mml:mi mathvariant="italic">α</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>,</mml:mo><mml:mi>p</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo><mml:mo>⋅</mml:mo><mml:msub><mml:mi>N</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>p</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo><mml:mo>⋅</mml:mo><mml:mi>L</mml:mi><mml:mo>⋅</mml:mo><mml:mi>C</mml:mi></mml:mrow></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          Here <inline-formula><mml:math id="M202" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the Loschmidt constant and <inline-formula><mml:math id="M203" display="inline"><mml:mi mathvariant="italic">ν</mml:mi></mml:math></inline-formula> represents the wavenumber. By knowing the pressure <inline-formula><mml:math id="M204" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula>, the temperature <inline-formula><mml:math id="M205" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> and the optical path length <inline-formula><mml:math id="M206" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> of the measurement cell, the software can calculate the absorption coefficient <inline-formula><mml:math id="M207" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> and the mole fraction <inline-formula><mml:math id="M208" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> of the measured species <xref ref-type="bibr" rid="bib1.bibx16" id="paren.30"/>. The absorption coefficient <inline-formula><mml:math id="M209" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> represents the shape of the Voigt profile for a specific molecule including the Half-Width-Half-Maximum (HWHM) of its absorption line profile if only one such molecule is observed (see Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>). The mole fraction <inline-formula><mml:math id="M210" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> then scales <inline-formula><mml:math id="M211" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> for more than one molecule.</p>
      <p id="d2e3068">In this paper we use two different versions of the MGA<sup>3</sup> fitting software. The original software of our MGA<sup>3</sup> model, which we denote as version 1 (v1) (V30.0.171.0), does not correct for water vapor dependencies. That means that it fits each measured absorption line applying Eq. (<xref ref-type="disp-formula" rid="Ch1.E6"/>) and calculates the mole fraction <inline-formula><mml:math id="M214" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula>, but does not account for dilution and it cannot account sufficiently enough for all quantum-mechanical effects, such as water vapor line broadening, on the data, since not all processes are known or can be determined. To correct for these water vapor dependencies we conducted a water vapor experiment in the laboratory which we use to determine an empirical water vapor correction as shown in Sect. <xref ref-type="sec" rid="Ch1.S3"/>. This correction is then applied during the data post-processing to the already retrieved <inline-formula><mml:math id="M215" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> time series. In parallel, an updated version of the fitting software was developed by MIRO Analytical. The new version is based on the same laboratory experiment and now includes a correction for water vapor dilution and broadening effects already implemented in the fitting process of the spectra. The software version (V30.1.59.0) is in the following referred to as version 2 (v2). The resulting v2 time series of the retrieved mole fractions <inline-formula><mml:math id="M216" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> does not longer require the postfit corrections as in v1.</p>
</sec>
<sec id="Ch1.S2.SS5">
  <label>2.5</label><title>Fitting with constant HWHM – the <inline-formula><mml:math id="M217" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> option</title>
      <p id="d2e3131">For the software version v1, the MGA<sup>3</sup> has the option to activate or deactivate the <inline-formula><mml:math id="M219" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>, which is, within the MIRO software, an internal measure for the HWHM of each absorption line and therefore for the absorption coefficient <inline-formula><mml:math id="M220" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> (see Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>). If the <inline-formula><mml:math id="M221" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> is deactivated, the MGA<sup>3</sup> freezes the HWHM of the respective absorption line for all upcoming spectra and uses the last used value when the <inline-formula><mml:math id="M223" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> was still active. This means, however, that consequently the mole fraction <inline-formula><mml:math id="M224" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> in the fitting function (<xref ref-type="disp-formula" rid="Ch1.E6"/>) has to account for any changes that would occur in <inline-formula><mml:math id="M225" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula>. This leads to deviations from the actual values in <inline-formula><mml:math id="M226" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula>. However, with high water vapor contents in the sample air, as we show in Appendix <xref ref-type="sec" rid="App1.Ch1.S1"/>, the HWHM solely depends on water vapor for our N<sub>2</sub>O spectral line. Based on this, the mole fraction <inline-formula><mml:math id="M228" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> time series with a frozen <inline-formula><mml:math id="M229" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> can subsequently be corrected by an empirical water vapor correction. In the following, we denote this water vapor corrected data as v1-<inline-formula><mml:math id="M230" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off. To enforce the same behavior for all v1-<inline-formula><mml:math id="M231" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off refit-processes as much as possible, we deactivate the <inline-formula><mml:math id="M232" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> always when dry gas is measured and therefore no water vapor should be present.</p>
      <p id="d2e3254">At this point, the mole fractions retrieved by v1-<inline-formula><mml:math id="M233" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off should not differ compared to water vapor corrected data retrieved with v1 and an activated <inline-formula><mml:math id="M234" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> – from here on denoted as v1-<inline-formula><mml:math id="M235" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on. However, due to the <inline-formula><mml:math id="M236" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> being kept constant in v1-<inline-formula><mml:math id="M237" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off the fitting software has one  parameter less to account for in the fitting process which results in less numerical noise in <inline-formula><mml:math id="M238" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> compared to v1-<inline-formula><mml:math id="M239" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on. Software version v2 does not have a <inline-formula><mml:math id="M240" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> option and already corrects for water, and therefore will be simply denoted as v2. These correction approaches will now be discussed in more detail in Sect. <xref ref-type="sec" rid="Ch1.S3"/>.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Water vapor correction approaches of N<sub>2</sub>O in this study</title>
      <p id="d2e3335">Water vapor is highly variable in the atmosphere with 1–10 ppm in the Upper Troposphere – Lower Stratosphere (UTLS) <xref ref-type="bibr" rid="bib1.bibx18" id="paren.31"/> and even up to 30 000 ppm within the tropical boundary layer as shown in Fig. <xref ref-type="fig" rid="F5"/> from the ASIA-AQ measurements. Due to this high variability of water vapor in different regions of the world and its volatility, GHG measurements are usually reported in dry mole fractions for better comparability, which requires precise water vapor measurements at all times <xref ref-type="bibr" rid="bib1.bibx5 bib1.bibx34" id="paren.32"/>. The first step is to eliminate the dilution from the gas due to the present H<sub>2</sub>O by using the following equation:

          <disp-formula id="Ch1.E7" content-type="numbered"><label>7</label><mml:math id="M243" display="block"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>,</mml:mo><mml:mi mathvariant="normal">abs</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

        Here, <inline-formula><mml:math id="M244" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> denotes the mole fraction of N<sub>2</sub>O diluted by H<sub>2</sub>O. <inline-formula><mml:math id="M247" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mo>,</mml:mo><mml:mi mathvariant="normal">abs</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the absolute mole fraction of the H<sub>2</sub>O not influenced by any spectroscopical effects distorting the the measurements. <inline-formula><mml:math id="M249" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> represents the mole fraction of N<sub>2</sub>O in the gas mixture after the removal of H<sub>2</sub>O. However, additional spectroscopic effects, such as water vapor line broadening, or instrument-specific behaviors in the measurements can have an impact on the data if not accounted for correctly or not at all. Those effects then often have to be corrected by using an empirical water vapor correction, also specific to each instrument (e.g. <xref ref-type="bibr" rid="bib1.bibx5 bib1.bibx34 bib1.bibx27 bib1.bibx14" id="altparen.33"/>).</p>
      <p id="d2e3493">Since the original MGA<sup>3</sup> software v1 does not provide a water vapor correction, neither for dilution nor completely for spectroscopic effects, we first derive an empirical water vapor correction from a laboratory experiment, further described  in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/>. With the parameters <inline-formula><mml:math id="M253" display="inline"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M254" display="inline"><mml:mrow><mml:msub><mml:mi>b</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> determined from a quadratic function in the laboratory, we apply the following water vapor correction equation also used by <xref ref-type="bibr" rid="bib1.bibx34" id="text.34"/> to account for all potential H<sub>2</sub>O dependencies:

          <disp-formula id="Ch1.E8" content-type="numbered"><label>8</label><mml:math id="M256" display="block"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msubsup><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:msub><mml:mi>b</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        which we will explain more thoroughly in Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>. Here <inline-formula><mml:math id="M257" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the mole fraction of H<sub>2</sub>O as measured by the instrument possibly including the influence spectroscopical and dilution effects. In the following, we shortly introduce how we attain four water vapor corrected mole fraction data sets, retrieved from a single measured spectral data set, by different approaches.</p>
<sec id="Ch1.S3.SSx1" specific-use="unnumbered">
  <title>v1-<inline-formula><mml:math id="M259" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on</title>
      <p id="d2e3651">The wet mole fractions <inline-formula><mml:math id="M260" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for N<sub>2</sub>O and <inline-formula><mml:math id="M262" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> for H<sub>2</sub>O are retrieved by the software version v1 and with an activated <inline-formula><mml:math id="M264" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>. The time series <inline-formula><mml:math id="M265" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is then water vapor corrected to obtain <inline-formula><mml:math id="M266" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> by using Eq. (<xref ref-type="disp-formula" rid="Ch1.E8"/>). The data for the lab experiment from which we derive our correction is also fitted with the software version v1 with an active <inline-formula><mml:math id="M267" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/>).</p>
</sec>
<sec id="Ch1.S3.SSx2" specific-use="unnumbered">
  <title>v1-<inline-formula><mml:math id="M268" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off</title>
      <p id="d2e3756">This approach is identical to v1-<inline-formula><mml:math id="M269" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on except that the <inline-formula><mml:math id="M270" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> is deactivated during all fitting and retrieval processes by the MGA<sup>3</sup> software.</p>
</sec>
<sec id="Ch1.S3.SSx3" specific-use="unnumbered">
  <title>v1-<inline-formula><mml:math id="M272" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH</title>
      <p id="d2e3796">A precise water vapor correction approach requires precise water vapor measurements. Hence, for this specific approach, we first retrieve the wet mole fractions <inline-formula><mml:math id="M273" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for N<sub>2</sub>O and <inline-formula><mml:math id="M275" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> for H<sub>2</sub>O with a deactivated <inline-formula><mml:math id="M277" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>, as for v1-<inline-formula><mml:math id="M278" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off, and then compare our MGA<sup>3</sup>-H<sub>2</sub>O measurements to the H<sub>2</sub>O measurements made by NASA's well established Diode-Laser-Hygrometer (DLH) at the ASIA-AQ campaign <xref ref-type="bibr" rid="bib1.bibx10" id="paren.35"/>. Thereby, we checked the stability of the MGA<sup>3</sup> water vapor measurements over multiple flights and adjusted the MGA<sup>3</sup>-H<sub>2</sub>O measurements accordingly to the DLH-H<sub>2</sub>O measurements to achieve the same standard for the MGA<sup>3</sup>-H<sub>2</sub>O measurements over all the flights (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/> for more details). The mean behavior of the MGA<sup>3</sup>-H<sub>2</sub>O measurements of all flights compared to the DLH-H<sub>2</sub>O measurements is also used to calibrate the the MGA<sup>3</sup>-H<sub>2</sub>O measurements from the laboratory experiment from which the water vapor correction is derived. Then the DLH-adjusted <inline-formula><mml:math id="M293" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and the DLH-adjusted correction function from the laboratory experiment are used for correcting <inline-formula><mml:math id="M294" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M295" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> using the correction function (<xref ref-type="disp-formula" rid="Ch1.E8"/>).</p>
</sec>
<sec id="Ch1.S3.SSx4" specific-use="unnumbered">
  <title>v2</title>
      <p id="d2e4041">In this approach, we use the newly implemented MGA<sup>3</sup> retrieval software v2 which already includes a water vapor correction based on the same laboratory experiment as used for the previous approaches. The water vapor correction, however, is applied already while fitting the spectra and not after the N<sub>2</sub>O mole fraction <inline-formula><mml:math id="M298" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is retrieved. Here, the H<sub>2</sub>O spectra are directly used to correct the N<sub>2</sub>O spectra and directly report corrected <inline-formula><mml:math id="M301" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> mole fractions. The H<sub>2</sub>O spectra or measurements are not adjusted to the DLH measurements beforehand as for v1-<inline-formula><mml:math id="M303" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH.</p>
</sec>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Laboratory Experiment</title>
      <p id="d2e4127">In this section, we explain the setup of the laboratory experiment for the water vapor correction, how we conducted it and how we prepared the data retrieved from this experiment for the water vapor correction equation. For the laboratory experiment, we change the calibration system in Fig. <xref ref-type="fig" rid="F1"/> from the “in-flight calibration” configuration to the “laboratory humidifying” configuration in Fig. <xref ref-type="fig" rid="F3"/> and only use the calibration gas inlet of the MGA<sup>3</sup> throughout the whole experiment. The sample gas is provided by a gas cylinder (cal gas 1) and is first divided into two sub-lines, which are controlled by a mass flow controller each. One sub-line (line 1) is provided with only 3 slpm by its mass flow controller (MFC 1), since the humidifier (Dew Point Generator LI-610, LICOR) only operates with mass flows up to <inline-formula><mml:math id="M305" display="inline"><mml:mn mathvariant="normal">2.5</mml:mn></mml:math></inline-formula> slpm. The excess gas in line 1 is then released through the overflow behind the MFC 1 to protect the humidifier. The output of the humidifier is controlled in a range of 0–2.5 slpm with a valve on the humidifier itself. The second sub-line (line 2) is provided with 0–5 slpm by the MFC 2 which directly merges with the humidified output from line 1. The length of the mixing line is <inline-formula><mml:math id="M306" display="inline"><mml:mn mathvariant="normal">1.5</mml:mn></mml:math></inline-formula> m to allow for optimal mixing of dry gas and humidified gas. The merged gas then directly flowes into the MGA<sup>3</sup>, which is set to operate with a mass flow of <inline-formula><mml:math id="M308" display="inline"><mml:mn mathvariant="normal">1.9</mml:mn></mml:math></inline-formula> slpm for this experiment. The excess gas in the mixing line is released through an overflow in front of the MGA<sup>3</sup>. The second gas, cal gas 2, is used only for calibration purposes. The settings are the same as in the airborne setup at the GHGMon and the ASIA-AQ campaigns (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS2"/>) with a cell pressure of  <inline-formula><mml:math id="M310" display="inline"><mml:mn mathvariant="normal">70</mml:mn></mml:math></inline-formula> hPa and a cell temperature <inline-formula><mml:math id="M311" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> of 25 °C.</p>

      <fig id="F3"><label>Figure 3</label><caption><p id="d2e4201">Scheme of the setup of the water vapor laboratory experiment. To fully function the orange box gets exchanged with the orange box of the in-flight calibration configuration in Fig. <xref ref-type="fig" rid="F1"/>.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f03.png"/>

        </fig>

      <p id="d2e4212">For the experiment, the MFC 2 is first set to <inline-formula><mml:math id="M312" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> slpm and the humidifier output to <inline-formula><mml:math id="M313" display="inline"><mml:mn mathvariant="normal">0</mml:mn></mml:math></inline-formula> slpm, allowing only for the dry gas from cylinder 1 to be sampled. Then, the output of the humidifier is increased stepwise from <inline-formula><mml:math id="M314" display="inline"><mml:mn mathvariant="normal">0</mml:mn></mml:math></inline-formula> to <inline-formula><mml:math id="M315" display="inline"><mml:mn mathvariant="normal">2.5</mml:mn></mml:math></inline-formula> slpm, increasing the mole fraction of water vapor in the mixing line. Once the maximum mass flow for the humidifier output is reached, the mass flow of MFC 2 is incrementally decreased from <inline-formula><mml:math id="M316" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> to <inline-formula><mml:math id="M317" display="inline"><mml:mn mathvariant="normal">0</mml:mn></mml:math></inline-formula> slpm, further increasing the humidity in the merged gas until only the output from the humidifier is sampled. Thereby, a range of water vapor mole fractions of 0 %–3 % is covered. This process of humidifying is repeated four times. Before and after each repetition, the gas from cylinder 2 is sampled for calibration purposes.</p>
      <p id="d2e4259">The recorded spectral data are then refitted with three different water correction approaches. Twice with the original software version v1 (once with an activated <inline-formula><mml:math id="M318" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> and once with a deactivated <inline-formula><mml:math id="M319" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>) and once with the updated version v2. Figure <xref ref-type="fig" rid="F4"/> shows the retrieved N<sub>2</sub>O mole fractions from all those three approaches versus the retrieved H<sub>2</sub>O mole fractions after calibrating the time series to the dry cylinder gases. As obvious from Fig. 4a and b for v1, the uncorrected N<sub>2</sub>O (blue dots) mole fraction varies by more than 10–18 ppb in humid versus dry conditions. The cyan line gives the expected impact of the dilution effect only compared to dry conditions. The measured raw data deviate from the expected behavior due to spectroscopic effects like pressure broadening, which not all can be accounted for by the software in general. Also the pressure self broadening of H<sub>2</sub>O can be a cause of deviation in the measurements <xref ref-type="bibr" rid="bib1.bibx34" id="paren.36"/> if not corrected for. Furthermore, we only use zero measurements to calibrate the H<sub>2</sub>O, which could be a reason for the deviations from the cyan line. Since we use dry calibration gas in both cylinders, we cannot account for changes in sensitivity of the H<sub>2</sub>O measurements for values above <inline-formula><mml:math id="M326" display="inline"><mml:mn mathvariant="normal">0</mml:mn></mml:math></inline-formula>. With the deactivated, frozen <inline-formula><mml:math id="M327" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> in v1 the deviation is larger than with the activated <inline-formula><mml:math id="M328" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> since the water vapor line broadening is not accounted for in this setting (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS5"/>). Figure <xref ref-type="fig" rid="F4"/>c shows the mole fractions retrieved with the updated software version v2, in which the N<sub>2</sub>O mole fractions are already corrected for water vapor during the fitting process of the measured spectra (grey dots). For the raw data in Fig. <xref ref-type="fig" rid="F4"/>a and b we first have to derive a correction which leads us to the corrected data sets v1-<inline-formula><mml:math id="M330" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on and v1-<inline-formula><mml:math id="M331" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off (grey dots). This, we show in Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>.</p>

      <fig id="F4"><label>Figure 4</label><caption><p id="d2e4392">In panels <bold>(a)</bold> and <bold>(b)</bold> we can see the behavior of the raw N<sub>2</sub>O with increasing H<sub>2</sub>O mole fractions (blue dots) during laboratory water vapor experiment for v1-<inline-formula><mml:math id="M334" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on and v1-<inline-formula><mml:math id="M335" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off. The red lines are fitting functions giving us the parameters for our water vapor correction function in Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>. The cyan line shows the expected behavior of the raw mole fractions if only dilution was having an effect on the measurements. The grey dots are the blue dots corrected by the water vapor correction function (<xref ref-type="disp-formula" rid="Ch1.E17"/>) in Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>. In panel <bold>(c)</bold> the grey dots represent the raw mole fraction output of the experiment when reprocessed with version v2 of the MGA-ReFit software. The data were are already corrected for water vapor influences based on the same data in panels <bold>(a)</bold> and <bold>(b)</bold> while they were being reprocessed.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f04.png"/>

        </fig>


</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Water Correction Function</title>
      <p id="d2e4466">In the next step, we correct the raw N<sub>2</sub>O data in Fig. <xref ref-type="fig" rid="F4"/>a and b and derive a water vapor correction function. For this, the wet raw data <inline-formula><mml:math id="M337" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">lab</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">wet</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> given in Fig. <xref ref-type="fig" rid="F4"/>a and b are fitted with a quadratic function (red line), giving us the parameters <inline-formula><mml:math id="M338" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M339" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M340" display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula>:

            <disp-formula id="Ch1.E9" content-type="numbered"><label>9</label><mml:math id="M341" display="block"><mml:mrow><mml:mi mathvariant="normal">fit</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mi>a</mml:mi><mml:mo>⋅</mml:mo><mml:msubsup><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:mi>b</mml:mi><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:mi>d</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          Here, <inline-formula><mml:math id="M342" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the H<sub>2</sub>O mole fraction. In an ideal fit, the parameter <inline-formula><mml:math id="M344" display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula> represents the actual value of the dry cylinder mole fraction for <inline-formula><mml:math id="M345" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula> and therefore simultaneously the dry target value after the water vapor correction is applied for all <inline-formula><mml:math id="M346" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>. To obtain the water vapor corrected mole fraction <inline-formula><mml:math id="M347" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">lab</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">dry</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula> for N<sub>2</sub>O in this laboratory experiment, the value of the correction function (<xref ref-type="disp-formula" rid="Ch1.E9"/>) is subtracted without the parameter <inline-formula><mml:math id="M349" display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula> from <inline-formula><mml:math id="M350" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">lab</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">wet</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>:

            <disp-formula id="Ch1.E10" content-type="numbered"><label>10</label><mml:math id="M351" display="block"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">lab</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">dry</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mi mathvariant="normal">lab</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">wet</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:mi>a</mml:mi><mml:mo>⋅</mml:mo><mml:msubsup><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:mi>b</mml:mi><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>)</mml:mo><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          However, the parameters of this fit function apply only for the specific mole fraction <inline-formula><mml:math id="M352" display="inline"><mml:mi>d</mml:mi></mml:math></inline-formula> of the used cylinder and not necessarily for cylinders with random mole fractions <inline-formula><mml:math id="M353" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. If a humidified air sample containing no N<sub>2</sub>O were sampled, these specifically determined parameters would still produce a correction value for the corresponding <inline-formula><mml:math id="M355" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, despite the absence of the N<sub>2</sub>O. To account for any other values <inline-formula><mml:math id="M357" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> in the cylinder, we use following boundary condition:

                <disp-formula specific-use="gather" content-type="numbered"><mml:math id="M358" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E11"><mml:mtd><mml:mtext>11</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>⇔</mml:mo><mml:msub><mml:mi mathvariant="normal">fit</mml:mi><mml:mi>x</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mspace linebreak="nobreak" width="1em"/><mml:mo>∀</mml:mo><mml:mspace linebreak="nobreak" width="0.25em"/><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E12"><mml:mtd><mml:mtext>12</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mo>⇒</mml:mo><mml:mi>a</mml:mi><mml:mo>,</mml:mo><mml:mi>b</mml:mi><mml:mo>,</mml:mo><mml:mi>d</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

          and assume that the parameters <inline-formula><mml:math id="M359" display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M360" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M361" display="inline"><mml:mi>c</mml:mi></mml:math></inline-formula> – consequently the fit Eq. (<xref ref-type="disp-formula" rid="Ch1.E9"/>) – approach 0 proportionally with decreasing mole fractions <inline-formula><mml:math id="M362" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, giving:

                <disp-formula specific-use="gather" content-type="numbered"><mml:math id="M363" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E13"><mml:mtd><mml:mtext>13</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi>a</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>a</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow><mml:mrow><mml:mi>d</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>a</mml:mi><mml:mi>d</mml:mi></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E14"><mml:mtd><mml:mtext>14</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:mi>b</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>b</mml:mi><mml:mi>d</mml:mi></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>b</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E15"><mml:mtd><mml:mtext>15</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle displaystyle="true" class="stylechange"/><mml:mi>d</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E16"><mml:mtd><mml:mtext>16</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:mfenced open="(" close=")"><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msubsup><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:msub><mml:mi>b</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

          <inline-formula><mml:math id="M364" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the measured wet mole fraction of N<sub>2</sub>O using the new cylinder with <inline-formula><mml:math id="M366" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. The fit parameters in Eqs. (<xref ref-type="disp-formula" rid="Ch1.E13"/>)–(<xref ref-type="disp-formula" rid="Ch1.E15"/>) are now dependent on the mole fractions <inline-formula><mml:math id="M367" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> in the cylinder and from Eq. (<xref ref-type="disp-formula" rid="Ch1.E16"/>) we get:

            <disp-formula id="Ch1.E17" content-type="numbered"><label>17</label><mml:math id="M368" display="block"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">dry</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>a</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msubsup><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>+</mml:mo><mml:msub><mml:mi>b</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          which can finally be used for any random measurement <inline-formula><mml:math id="M369" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi mathvariant="normal">wet</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> with a simultaneously measured <inline-formula><mml:math id="M370" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>. Equation (<xref ref-type="disp-formula" rid="Ch1.E17"/>) is the same as the one used by <xref ref-type="bibr" rid="bib1.bibx5" id="text.37"/> and <xref ref-type="bibr" rid="bib1.bibx34" id="text.38"/>, also with the assumption that the water vapor correction is proportional to the mole fraction of our observed species.</p>
      <p id="d2e5368">The correction Eq. (<xref ref-type="disp-formula" rid="Ch1.E17"/>) is then applied to the raw data in Fig. <xref ref-type="fig" rid="F4"/>a and b and results in the grey corrected data v1-<inline-formula><mml:math id="M371" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on and v1-<inline-formula><mml:math id="M372" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off. With this, our retrieved data is corrected for water vapor and influences and should be independent of water vapor changes either by dilution or spectral effects like line broadening. The main difference between the <inline-formula><mml:math id="M373" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on and <inline-formula><mml:math id="M374" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off retrieved data is that the noise in the data for the <inline-formula><mml:math id="M375" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off data is smaller (see Sect. <xref ref-type="sec" rid="Ch1.S2.SS5"/>) by roughly <inline-formula><mml:math id="M376" display="inline"><mml:mn mathvariant="normal">42</mml:mn></mml:math></inline-formula> % compared to its respective <inline-formula><mml:math id="M377" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on retrieved data, which will be discussed in Sect. <xref ref-type="sec" rid="Ch1.S3.SS5"/> in more detail.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>H<sub>2</sub>O calibration against DLH absolute ambient measurements</title>
      <p id="d2e5447">The quality of the water vapor measurement is decisive for a precise water vapor correction. While the absolute accuracy is not of main importance, the stability of the water vapor measurement is, hence, the replicability of the H<sub>2</sub>O measurements over time. To analyze the stability of the MGA<sup>3</sup>-H<sub>2</sub>O measurements in our setup, we compare data from 14 flights from the ASIA-AQ campaign with absolute ambient H<sub>2</sub>O vapor measurements measured by the established DLH. We use the DLH because it reliably reports stable water vapor measurements which can be used to effectively correct the MGA<sup>3</sup> water vapor measurements. In our airborne measurement setup the MGA<sup>3</sup>-H<sub>2</sub>O is only zeroed with our dry cylinder gases, leading to differences in the data between the two instruments. Also the self broadening of H<sub>2</sub>O can lead to differences as discussed in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/>. In Fig. <xref ref-type="fig" rid="F5"/>a the DLH-H<sub>2</sub>O for each of the 14 flights is plotted against the respective MGA<sup>3</sup>-H<sub>2</sub>O data for the <inline-formula><mml:math id="M390" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off setting. The flights were conducted over a time span of roughly two months. The lines are polynomial fits (second order) of the measurements, calculated by applying orthogonal distance regressions. The dashed red line shows a slope of 1. The dashed black line shows the mean of all curves which in this case is a orthogonal distance regression fit to the data of all the lines and which is also a quadratic function described with <inline-formula><mml:math id="M391" display="inline"><mml:mrow><mml:mi>f</mml:mi><mml:mo>(</mml:mo><mml:mi>x</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mi>a</mml:mi><mml:msup><mml:mi>x</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:mi>b</mml:mi><mml:mi>x</mml:mi><mml:mo>+</mml:mo><mml:mi>d</mml:mi></mml:mrow></mml:math></inline-formula>. The difference in the length of every curve is due to the differences in the maximum measured humidity during each flight.</p>

      <fig id="F5"><label>Figure 5</label><caption><p id="d2e5598">In panel <bold>(a)</bold> we plotted the DLH-H<sub>2</sub>O measurements against the MGA<sup>3</sup>-H<sub>2</sub>O measurements for the mole fractions retrieved with v1 with a deactivated <inline-formula><mml:math id="M395" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> for 14 ASIA-AQ flights from 6 February to 25 March. In general, our instrumental setup  measured less H<sub>2</sub>O than DLH. With increasing H<sub>2</sub>O the MGA<sup>3</sup> measurements seem to deviate more from each other indicating changes in sensitivity of the instrument. The black dashed line shows the mean for all flights which is a orthogonal distance regression fit through all the data of the lines. Panel <bold>(b)</bold> shows again the same as Fig. <xref ref-type="fig" rid="F4"/>b but now the blue raw data is first corrected by the respective dashed black line in panel <bold>(b)</bold> resulting in the “DLH-corrected” purple dots. The red lines are now the fitting lines for the purple data, which parameters now can be used to derive the new correction v1-<inline-formula><mml:math id="M399" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f05.png"/>

        </fig>

      <p id="d2e5688">In general, the DLH measures about <inline-formula><mml:math id="M400" display="inline"><mml:mrow><mml:mi>b</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1.16</mml:mn></mml:mrow></mml:math></inline-formula> times higher H<sub>2</sub>O values than the MGA<sup>3</sup> with our instrumental setup, which is mainly due to not being able to conduct a two-point-calibration as mentioned. Other minor reasons could be, for example, water vapor tube dampening effects through the long <inline-formula><mml:math id="M403" display="inline"><mml:mn mathvariant="normal">6.5</mml:mn></mml:math></inline-formula> m PTFE inlet tubing in our setup. At the instrument flow rate of approx. 13 slpm, it takes about <inline-formula><mml:math id="M404" display="inline"><mml:mn mathvariant="normal">2</mml:mn></mml:math></inline-formula> s at 1 atm until the sample air reaches the measuring cell, during which water vapor could attach and slowly unstick from the inner tubing walls. Still, the results show that H<sub>2</sub>O measurements for the flights diverge for higher H<sub>2</sub>O values, indicating changes in the sensitivity. In principle, this can only be accounted for by a sufficient two-point-calibration as explained in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/>. The changing behavior over the flights, however, means that the once attained correction equation in the laboratory will behave slightly differently for every flight unless the MGA<sup>3</sup>-H<sub>2</sub>O is standardized to a norm.</p>
      <p id="d2e5775">To account for this variability in behavior of the MGA<sup>3</sup>-H<sub>2</sub>O from flight to flight, we constructed a new correction specifically for all the ASIA-AQ flights in addition to the already existing v1-<inline-formula><mml:math id="M411" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off approach in Sect. <xref ref-type="sec" rid="Ch1.S3.SS2"/>, called v1-<inline-formula><mml:math id="M412" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH, which can be seen in Fig. <xref ref-type="fig" rid="F5"/>b (grey dots). First, since the H<sub>2</sub>O measurement in the laboratory water vapor experiment cannot be calibrated against absolute reference values – due to our used humidifying configuration setup not being able to provide such an accurate value – we assume that the H<sub>2</sub>O behavior in the experiment is similar to the mean behavior of all flights (dashed black line in Fig. <xref ref-type="fig" rid="F5"/>a). Thus, we correct our laboratory experiment H<sub>2</sub>O values with this mean (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS4"/> for explanation). This results in the purple DLH corrected data in Fig. <xref ref-type="fig" rid="F5"/>b. We can see that the DLH adjusted N<sub>2</sub>O raw data is closer to the cyan line which represents the ideal behavior if only dilution existed. Now, the fit (red line) is used for deriving the parameters of our water vapor correction in the same way as for v1-<inline-formula><mml:math id="M417" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off. However, before the correction function is applied to the flight data, we first correct the H<sub>2</sub>O flight measurements with their respective line in Fig. <xref ref-type="fig" rid="F5"/>a to assure that all flight measurements and the laboratory H<sub>2</sub>O measurements are “calibrated” to the same standard, which in this case are the DLH measurements. Now, the water vapor correction function can be applied to the flight data giving the water vapor corrected mole fraction data. This approach is denoted as v1-<inline-formula><mml:math id="M420" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH.</p>
      <p id="d2e5893">In the next section, we compare the results from the different correction approaches v1-<inline-formula><mml:math id="M421" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off, v1-<inline-formula><mml:math id="M422" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH and v2.</p>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Comparison of the different water correction approaches</title>
      <p id="d2e5919">In this chapter, we compare the data retrieved by the different MGA<sup>3</sup> software versions and water correction approaches v1-<inline-formula><mml:math id="M424" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off, v1-<inline-formula><mml:math id="M425" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH and v2 with the data measured by NASA's established DACOM spectrometer. The DACOM is a TDLAS designed for CO measurements but it also measures CH<sub>4</sub> and N<sub>2</sub>O. It has a temporal resolution of <inline-formula><mml:math id="M428" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> Hz and dries the sample air via a Nafion tube before sampling, negating water vapor interference and dilution effects. Our calibration cylinders for the MGA<sup>3</sup> were cross calibrated against the NOAA calibration cylinders of DACOM. This makes the DACOM measurements ideal for the validation of our water vapor correction approaches for the MGA<sup>3</sup>-N<sub>2</sub>O measurements. For a better comparison, the MGA<sup>3</sup> data was resampled to <inline-formula><mml:math id="M433" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> Hz to match the DACOM data. We chose to compare three flights in Thailand for which data from both instruments are available, well calibrated and, most importantly, high H<sub>2</sub>O variability was measured.</p>
      <p id="d2e6024">Figure <xref ref-type="fig" rid="F6"/>a, b and c illustrate the difference between the DACOM-N<sub>2</sub>O data and the MGA<sup>3</sup>-N<sub>2</sub>O for three selected ASIA-AQ flights (25, 21 and 18 March 2024). Different colors represent data retrieved using the different MGA<sup>3</sup> approaches (v1-<inline-formula><mml:math id="M439" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off in orange, v1-<inline-formula><mml:math id="M440" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH in green and v2 in black). The lines represent the mean values for <inline-formula><mml:math id="M441" display="inline"><mml:mn mathvariant="normal">0.01</mml:mn></mml:math></inline-formula> % (<inline-formula><mml:math id="M442" display="inline"><mml:mn mathvariant="normal">100</mml:mn></mml:math></inline-formula> ppm) H<sub>2</sub>O bins. The blue shaded areas show the combined uncertainties of the DACOM measurements and the v1-<inline-formula><mml:math id="M444" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH data. However, for the combined uncertainties, we do not use the <inline-formula><mml:math id="M445" display="inline"><mml:mn mathvariant="normal">0.01</mml:mn></mml:math></inline-formula> % H<sub>2</sub>O bins resolution, but uncertainties of the full <inline-formula><mml:math id="M447" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> Hz resolution to capture the variability of the instruments more accurately. Since our MGA<sup>3</sup> calibration cylinders were calibrated against the DACOM NOAA cylinders, the accuracy determined from the uncertainty in the NOAA cylinders should have the same effect on the accuracy of our calibration cylinders. Therefore, for the combined uncertainty we only include the precision of DACOM and the total uncertainty of the MGA<sup>3</sup>, which includes the precision of each data point and the uncertainty of the cross calibration procedure. The uncertainties we used are always 1<inline-formula><mml:math id="M450" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> uncertainties.</p>

      <fig id="F6"><label>Figure 6</label><caption><p id="d2e6161">Differences between N<sub>2</sub>O data measured by DACOM and the MGA<sup>3</sup> for the different water vapor correction approaches v1-<inline-formula><mml:math id="M453" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off, v1-<inline-formula><mml:math id="M454" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH and v2 for three ASIA-AQ flights on the 25 March 2024 <bold>(a)</bold>, 21 March 2024 <bold>(b)</bold> and 18 March 2024 <bold>(c)</bold>. The colored lines show the mean values of the differences between DACOM and the MGA<sup>3</sup> corrected data in <inline-formula><mml:math id="M456" display="inline"><mml:mn mathvariant="normal">0.01</mml:mn></mml:math></inline-formula> % or <inline-formula><mml:math id="M457" display="inline"><mml:mn mathvariant="normal">100</mml:mn></mml:math></inline-formula> ppm H<sub>2</sub>O bins. The shaded blue areas represent the combined uncertainties of DACOM and the MGA<sup>3</sup> with v1-<inline-formula><mml:math id="M460" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH but at full resolution and not with the <inline-formula><mml:math id="M461" display="inline"><mml:mn mathvariant="normal">0.01</mml:mn></mml:math></inline-formula> % bin resolution.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f06.png"/>

        </fig>

      <p id="d2e6269">To quantify the agreement between the MGA<sup>3</sup> measurements and DACOM, we calculate the fraction of data points that overlap within the combined uncertainty of both instruments which is summarized in Table <xref ref-type="table" rid="T3"/>. In Fig. <xref ref-type="fig" rid="F6"/>a for the 25 March 2024, the difference between DACOM and v1-<inline-formula><mml:math id="M463" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off (orange line) is already very small with <inline-formula><mml:math id="M464" display="inline"><mml:mn mathvariant="normal">74.5</mml:mn></mml:math></inline-formula> % of data overlapping between the two instruments. This indicates that the behavior of H<sub>2</sub>O of the water laboratory experiment is actually close to the mean behavior for all ASIA-AQ flights (dashed black line, Fig. <xref ref-type="fig" rid="F5"/>) and therefore to the behavior during this flight. This is indicated by the differences for v1-<inline-formula><mml:math id="M466" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH (green line) which show only smaller deviations compared to v1-<inline-formula><mml:math id="M467" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off due to the application of the DLH-correction (<inline-formula><mml:math id="M468" display="inline"><mml:mn mathvariant="normal">74.4</mml:mn></mml:math></inline-formula> % overlap with DACOM). The differences for v2, however show a drift with increasing H<sub>2</sub>O mole fractions with <inline-formula><mml:math id="M470" display="inline"><mml:mn mathvariant="normal">60.8</mml:mn></mml:math></inline-formula> % of data overlapping DACOM. In particular, for H<sub>2</sub>O values above <inline-formula><mml:math id="M472" display="inline"><mml:mn mathvariant="normal">1.5</mml:mn></mml:math></inline-formula> % or 15 000 ppm the differences between DACOM and v2 are larger than the combined uncertainties. A reason for the drift can be unwanted behavior of the pressure regulator in our MGA<sup>3</sup> which is influenced by different amounts of water vapor in the sampled air. In the newer models the regulator is replaced by a new kind of regulator which does not show such influences of water vapor (personal communication with Oleg Aseev). In Fig. <xref ref-type="fig" rid="F6"/>b and c, the differences for v1-<inline-formula><mml:math id="M474" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off show deviations greater than <inline-formula><mml:math id="M475" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> ppb compared to DACOM. The overlap of the data is <inline-formula><mml:math id="M476" display="inline"><mml:mn mathvariant="normal">53.1</mml:mn></mml:math></inline-formula> % and <inline-formula><mml:math id="M477" display="inline"><mml:mn mathvariant="normal">70.1</mml:mn></mml:math></inline-formula> %, respectively. This can be explained by the indicated changes in the sensitivity of the MGA<sup>3</sup>-H<sub>2</sub>O measurements as discussed in Sect. <xref ref-type="sec" rid="Ch1.S3.SS3"/>. When corrected with DLH, however, the resulting v1-<inline-formula><mml:math id="M480" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH corrected data overlaps within <inline-formula><mml:math id="M481" display="inline"><mml:mn mathvariant="normal">79.4</mml:mn></mml:math></inline-formula> % and <inline-formula><mml:math id="M482" display="inline"><mml:mn mathvariant="normal">82.3</mml:mn></mml:math></inline-formula> % with DACOM data and the deviations for larger H<sub>2</sub>O values decrease. For the 21 and 18 March 2024 in v2 the same trends are found in Fig. <xref ref-type="fig" rid="F6"/>b and c as for the 25 March 2024 shown in Fig. <xref ref-type="fig" rid="F6"/>a.</p>

<table-wrap id="T3"><label>Table 3</label><caption><p id="d2e6464">Percentage of how many data points of the DACOM measurements overlap with MGA<sup>3</sup> data with different water vapor correction approaches applied within the combined uncertainties at <inline-formula><mml:math id="M485" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> Hz.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Flight</oasis:entry>
         <oasis:entry colname="col2">v1-<inline-formula><mml:math id="M486" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off</oasis:entry>
         <oasis:entry colname="col3">v1-<inline-formula><mml:math id="M487" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH</oasis:entry>
         <oasis:entry colname="col4">v2</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">(%)</oasis:entry>
         <oasis:entry colname="col3">(%)</oasis:entry>
         <oasis:entry colname="col4">(%)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">25 March 2024</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M488" display="inline"><mml:mn mathvariant="normal">74.5</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M489" display="inline"><mml:mn mathvariant="normal">74.4</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M490" display="inline"><mml:mn mathvariant="normal">60.8</mml:mn></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">21 March 2024</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M491" display="inline"><mml:mn mathvariant="normal">53.1</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M492" display="inline"><mml:mn mathvariant="normal">79.4</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M493" display="inline"><mml:mn mathvariant="normal">55.9</mml:mn></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">18 March 2024</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M494" display="inline"><mml:mn mathvariant="normal">70.1</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M495" display="inline"><mml:mn mathvariant="normal">82.3</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M496" display="inline"><mml:mn mathvariant="normal">62.1</mml:mn></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e6636">There are several possible reasons that the percentages of overlapping data with DACOM do not reach higher values than <inline-formula><mml:math id="M497" display="inline"><mml:mn mathvariant="normal">82</mml:mn></mml:math></inline-formula> %. First, of course, the two instruments are not identical and react inherently different to changes in the measured species especially due to the different setups (Nafion-dryer, inlet tubes, pump, mass flow, etc.). Here, the Nafion-dryer of the DACOM system and the inlet tubes of the MGA<sup>3</sup> could have an influence on the respective sample air, resulting into differences in the measurements. Second, DACOM used one additional calibration cylinder and calibrates every <inline-formula><mml:math id="M499" display="inline"><mml:mn mathvariant="normal">4</mml:mn></mml:math></inline-formula> min while our setup uses only two cylinders for calibrations every <inline-formula><mml:math id="M500" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> min, making our instrument potentially more prone to changes in sensitivity compared to DACOM. This issue can be overcome by using the same calibration method in the future. Third, it could be that the distance of the inlets for the two instruments of about <inline-formula><mml:math id="M501" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> m leads to the sampled air by both instruments not being identical. In the case of v1-<inline-formula><mml:math id="M502" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH, a last reason could be that the mean behavior of H<sub>2</sub>O for all flights in Fig. <xref ref-type="fig" rid="F5"/>a (dashed black line) correcting the laboratory experiment does not represent the actual true behavior. This could also explain the slight negative trend in N<sub>2</sub>O from lower to higher H<sub>2</sub>O values.</p>
      <p id="d2e6713">We conclude that the v1-<inline-formula><mml:math id="M506" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off approach could be improved by the additional DLH correction resulting in the v1-<inline-formula><mml:math id="M507" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH approach. The newer v2 version shows a significant drift for growing H<sub>2</sub>O mole fractions but matches DACOM until <inline-formula><mml:math id="M509" display="inline"><mml:mn mathvariant="normal">1.5</mml:mn></mml:math></inline-formula> % or 15 000 ppm H<sub>2</sub>O within the uncertainties. However, it does not need an additional adjustment with DLH data or data from other instruments as v1-<inline-formula><mml:math id="M511" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH.</p>
</sec>
<sec id="Ch1.S3.SS5">
  <label>3.5</label><title>N<sub>2</sub>O precision, noise and uncertainty</title>
      <p id="d2e6781">In Sect. <xref ref-type="sec" rid="Ch1.S2.SS5"/>, we explained the possibility of changing the <inline-formula><mml:math id="M513" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> setting and how it influences the fitting process. An advantage from the deactivation of the <inline-formula><mml:math id="M514" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> is, that the fitting software has one less parameter that has to be accounted for in the fitting process, leading to less noise in the retrieved mole fractions.</p>
      <p id="d2e6800">Therefore, we compare the precision of 14 ASIA-AQ flights refitted with the approaches v1-<inline-formula><mml:math id="M515" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on, v1-<inline-formula><mml:math id="M516" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH and v2. We determine the in-flight precision by calculating the mean of the precision values for each flight, obtained by propagating the standard deviations of all calibration time windows within the given flight, such as the one in Fig. <xref ref-type="fig" rid="F2"/>. The mean N<sub>2</sub>O precision for both the v1-<inline-formula><mml:math id="M518" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH version and the v2 version is about <inline-formula><mml:math id="M519" display="inline"><mml:mrow><mml:mn mathvariant="normal">42</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi><mml:mo>±</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> lower than for the v1-<inline-formula><mml:math id="M520" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on version. The best determined in-flight precision for a flight at ASIA-AQ with the v1-<inline-formula><mml:math id="M521" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH version was approximately <inline-formula><mml:math id="M522" display="inline"><mml:mn mathvariant="normal">0.17</mml:mn></mml:math></inline-formula> ppb.</p>
      <p id="d2e6875">Further uncertainties arise from the calibration and the water vapor correction of the data. We summarize the uncertainty budget in Table <xref ref-type="table" rid="T4"/> in percentages according to the contribution to the total uncertainty. After propagating the precision of the N<sub>2</sub>O measurements through the calibration Eq. (<xref ref-type="disp-formula" rid="Ch1.E3"/>) and the water vapor correction Eq. (<xref ref-type="disp-formula" rid="Ch1.E17"/>) we find, that in the mean across flights the precision of N<sub>2</sub>O contributes about <inline-formula><mml:math id="M525" display="inline"><mml:mn mathvariant="normal">93</mml:mn></mml:math></inline-formula> % to the squared total uncertainty. The H<sub>2</sub>O-precision, usually in the range of approximately 0.01 vol %, contributes approximately <inline-formula><mml:math id="M527" display="inline"><mml:mn mathvariant="normal">4.5</mml:mn></mml:math></inline-formula> %, the calibration procedure about <inline-formula><mml:math id="M528" display="inline"><mml:mn mathvariant="normal">0.05</mml:mn></mml:math></inline-formula> % and the water vapor correction procedure about <inline-formula><mml:math id="M529" display="inline"><mml:mn mathvariant="normal">2.2</mml:mn></mml:math></inline-formula> % to the total squared uncertainty. However, in this calculation, we assume that the uncertainties of the NOAA-cylinders used for cross calibrating our own calibration cylinders are <inline-formula><mml:math id="M530" display="inline"><mml:mn mathvariant="normal">0</mml:mn></mml:math></inline-formula> and therefore only apply the uncertainties of our calibration cylinders which are <inline-formula><mml:math id="M531" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula> ppb using standard errors. The squared uncertainty of the H<sub>2</sub>O measurements itself also increases by roughly <inline-formula><mml:math id="M533" display="inline"><mml:mn mathvariant="normal">40</mml:mn></mml:math></inline-formula> % after applying the DLH-correction to the ASIA-AQ data.</p>

<table-wrap id="T4"><label>Table 4</label><caption><p id="d2e6978">Contribution of the N<sub>2</sub>O-precision, H<sub>2</sub>O-precision, calibration and water vapor correction procedure to the total squared uncertainty for the v1-<inline-formula><mml:math id="M536" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off N<sub>2</sub>O data in percentages.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Mean</oasis:entry>
         <oasis:entry colname="col3">Min–Max</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">(%)</oasis:entry>
         <oasis:entry colname="col3">(%)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">precision N<sub>2</sub>O</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M539" display="inline"><mml:mn mathvariant="normal">93.25</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">88.05–97.27</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">precision H<sub>2</sub>O</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M541" display="inline"><mml:mn mathvariant="normal">4.49</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">1.55–7.53</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">calibration</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M542" display="inline"><mml:mn mathvariant="normal">0.04</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">0.01–0.1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">water vapor correction</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M543" display="inline"><mml:mn mathvariant="normal">2.22</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">0.9–4.8</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e7140">The precision depends crucially on the optics alignment. Usually, we recognize a misalignment by a drop in the detected laser intensity, by worsened residuals when fitting the spectra or by worsened precision values compared to previous measurements which all can be corrected again by realigning the mirrors. The mirrors directing the laser beams into the measuring cell can misalign when the instrument experiences heavy shocks. We also experienced a misalignment after transporting the instrument with a van over several hours on the highway. Onboard the Cessna at the GHGMon campaign we did not experience any clear misalignment over the course of roughly 50 flight hours (including transfer flights). Onboard the DC-8 at ASIA-AQ, we did not experience any clear changes in the alignment either for about 90 flight hours. In South Korea, even after warming up the device for 1–3 h from temperatures slightly above the freezing point over night to <inline-formula><mml:math id="M544" display="inline"><mml:mn mathvariant="normal">25</mml:mn></mml:math></inline-formula> °C in the optics compartment of the instrument we could not see any significant changes to the alignment and precision. However, after the transfer flight from South Korea to Thailand, we experienced a clear misalignment in the optics worsening the precision of the instrument by about 50 %–100 % for the last four campaign flights. The optics could be realigned again in the laboratory after the campaign. The source of the misalignment could have multiple reasons, e.g, heavier shocks than usual while landing, but we could not identify any specific cause. In general, we realign the optics before every campaign for optimal data quality. Because of a possible misalignment, we recommend to built in the MGA<sup>3</sup> in the top of a rack to have easier access to the mirrors while doing flight tests.</p>
      <p id="d2e7159">We conclude that the v1-<inline-formula><mml:math id="M546" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH and v2 versions give a better precision for the data than the v1-<inline-formula><mml:math id="M547" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-on version. However, for the v1-<inline-formula><mml:math id="M548" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH version to work, we have to determine an empirical water correction as described in Sect. <xref ref-type="sec" rid="Ch1.S3"/> whereas version v2 works with no additional data refinement after the mole fraction retrieval. The instrument is stable in regards of its optical alignment over whole campaigns with about 50 flight hours and longer. Nonetheless, we recommend a realignment of the optics before every campaign for optimal data quality.</p>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Stability of the DLR airborne MGA<sup>3</sup> system</title>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Allan Precision and calibration frequencies</title>
      <p id="d2e7211">In this section, we determine the stability of the MGA<sup>3</sup>-N<sub>2</sub>O via its Allan precision according to <xref ref-type="bibr" rid="bib1.bibx45" id="text.39"/>, as can be seen in Fig. <xref ref-type="fig" rid="F7"/>. We calculate the Allan precision from a <inline-formula><mml:math id="M552" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> min time series of a measured calibration gas in the laboratory on ground and discuss the optimal calibration times and frequencies for the in-situ measurement. The range of white noise can be found along the orange line. The two green lines show the maximum and the minimum slope where the behavior of the instrument shows a drift. Based on this, the optimum integration time <inline-formula><mml:math id="M553" display="inline"><mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">67</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula> s was determined by calculating the mean of the times between the intersects of the green and orange lines. In Table <xref ref-type="table" rid="T5"/>, the result for a set of integration times <inline-formula><mml:math id="M554" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula> can be seen, including two values that were given by the manufacturer. Our self-determined values are comparable to the manufacturer values but are slightly higher. Therefore, the data should be calibrated about every <inline-formula><mml:math id="M555" display="inline"><mml:mn mathvariant="normal">67</mml:mn></mml:math></inline-formula> s to avoid any drift in the data. However, this would lead to a duty cycle of about <inline-formula><mml:math id="M556" display="inline"><mml:mn mathvariant="normal">63</mml:mn></mml:math></inline-formula> % leading to a high and expensive calibration gas consumption. As a trade-off between data quality, gas consumption, and data acquisition, we chose to calibrate for <inline-formula><mml:math id="M557" display="inline"><mml:mn mathvariant="normal">40</mml:mn></mml:math></inline-formula> s in total every <inline-formula><mml:math id="M558" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> min leading to a duty cycle of about <inline-formula><mml:math id="M559" display="inline"><mml:mn mathvariant="normal">94</mml:mn></mml:math></inline-formula> %, as we already saw in Fig. <xref ref-type="fig" rid="F2"/> in an example from the ASIA-AQ campaign. The calibration time windows show stable behavior within their respective <inline-formula><mml:math id="M560" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> s and, in combination with the high cell exchange rate and after our experience at the GHGMon and ASIA-AQ campaigns, we suggest even shorter periods than <inline-formula><mml:math id="M561" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> s for the high and low standards in future flights, further improving the duty cycle of our system. We have also calculated the Allan precision for in-flight data. In this case, however, we measured calibration gas for only <inline-formula><mml:math id="M562" display="inline"><mml:mn mathvariant="normal">8</mml:mn></mml:math></inline-formula> min due to limited availability of gas during the campaign. Also, the data was part of an cabin pressure experiment where we cannot distinguish the effects of cabin pressure change and the actual changes in stability, which we will show in Sect. <xref ref-type="sec" rid="Ch1.S4.SS2"/>.</p>

      <fig id="F7"><label>Figure 7</label><caption><p id="d2e7334">Allan Precision for N<sub>2</sub>O. Values along the orange line are considered  white noise. The green lines show the minimum and maximum range for drift behavior. The optimal integration time <inline-formula><mml:math id="M564" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula> after which the drift sets in is shown with the black dot at <inline-formula><mml:math id="M565" display="inline"><mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">67</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:math></inline-formula> s.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f07.png"/>

        </fig>

<table-wrap id="T5"><label>Table 5</label><caption><p id="d2e7378">Allan Precision for different integration times <inline-formula><mml:math id="M566" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula> in Fig. <xref ref-type="fig" rid="F7"/>. The optimal integration time is at <inline-formula><mml:math id="M567" display="inline"><mml:mn mathvariant="normal">67</mml:mn></mml:math></inline-formula> s. The values for <inline-formula><mml:math id="M568" display="inline"><mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>, 200 s are slightly higher than the values given by the manufacturer.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Integration</oasis:entry>
         <oasis:entry colname="col2">Calculated</oasis:entry>
         <oasis:entry colname="col3">Manufacturer</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">time <inline-formula><mml:math id="M569" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">(ppb)</oasis:entry>
         <oasis:entry colname="col3">values (ppb)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">@<inline-formula><mml:math id="M570" display="inline"><mml:mn mathvariant="normal">0.1</mml:mn></mml:math></inline-formula> s</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M571" display="inline"><mml:mn mathvariant="normal">0.15</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">@<inline-formula><mml:math id="M572" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> s</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M573" display="inline"><mml:mn mathvariant="normal">0.05</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M574" display="inline"><mml:mn mathvariant="normal">0.03</mml:mn></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">@<inline-formula><mml:math id="M575" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> s</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M576" display="inline"><mml:mn mathvariant="normal">0.017</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">@<inline-formula><mml:math id="M577" display="inline"><mml:mn mathvariant="normal">67</mml:mn></mml:math></inline-formula> s</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M578" display="inline"><mml:mn mathvariant="normal">0.007</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">@<inline-formula><mml:math id="M579" display="inline"><mml:mn mathvariant="normal">100</mml:mn></mml:math></inline-formula> s</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M580" display="inline"><mml:mn mathvariant="normal">0.009</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">@<inline-formula><mml:math id="M581" display="inline"><mml:mn mathvariant="normal">200</mml:mn></mml:math></inline-formula> s</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M582" display="inline"><mml:mn mathvariant="normal">0.015</mml:mn></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M583" display="inline"><mml:mn mathvariant="normal">0.01</mml:mn></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Dependency on cabin pressure</title>
      <p id="d2e7615">As previously noted, the DC-8 aircraft has a pressurized cabin while the DLR Cessna aircraft is unpressurized. In the DC-8 the cabin pressure data are provided by the DC-8 Meteorological and Navigation Facility Instrumentation (MetNav). As a proxy for the cabin pressure in the Cessna, we use the static pressure measurement provided by the meteorological sensor package (METPOD). Previously, <xref ref-type="bibr" rid="bib1.bibx27" id="text.40"/> have shown cabin pressure dependencies in their data resulting in deviations of several ppb for pressures ranging from about <inline-formula><mml:math id="M584" display="inline"><mml:mn mathvariant="normal">1000</mml:mn></mml:math></inline-formula> hPa down to <inline-formula><mml:math id="M585" display="inline"><mml:mn mathvariant="normal">800</mml:mn></mml:math></inline-formula> hPa, which were corrected by a pressure differentiated calibration procedure. However, with this procedure the data is filtered by a condition where the influence of pressure is small, leading to high losses in the amount of data. <xref ref-type="bibr" rid="bib1.bibx14" id="text.41"/> also showed deviations in N<sub>2</sub>O within a similar pressure range. These deviations were accounted for by frequent calibrations.</p>

      <fig id="F8" specific-use="star"><label>Figure 8</label><caption><p id="d2e7649">On the left, N<sub>2</sub>O calibration gas measurements are plotted against the cabin pressure of the NASA DC-8. The pressure of the pressurized cabin was actively reduced from 840 to <inline-formula><mml:math id="M588" display="inline"><mml:mn mathvariant="normal">760</mml:mn></mml:math></inline-formula> hPa within <inline-formula><mml:math id="M589" display="inline"><mml:mn mathvariant="normal">8</mml:mn></mml:math></inline-formula> min. The slope of the fit function shows no significant drift in N<sub>2</sub>O. On the right we see the N<sub>2</sub>O calibration gas measurements plotted against the static pressure as a proxy for the cabin pressure, because the cabin of the DLR Cessna is not pressurized. During a descent within <inline-formula><mml:math id="M592" display="inline"><mml:mn mathvariant="normal">8</mml:mn></mml:math></inline-formula> min the static pressure increased from 820 to <inline-formula><mml:math id="M593" display="inline"><mml:mn mathvariant="normal">880</mml:mn></mml:math></inline-formula> hPa. The slope shows a significant drift for pressure changes of more than roughly <inline-formula><mml:math id="M594" display="inline"><mml:mn mathvariant="normal">150</mml:mn></mml:math></inline-formula> hPa, which would be higher than the precision of the instrument <inline-formula><mml:math id="M595" display="inline"><mml:mn mathvariant="normal">0.17</mml:mn></mml:math></inline-formula> ppb. However, the behavior seems to be less stable so that the drift does not seem to be connected to changes in cabin pressure alone.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f08.png"/>

        </fig>

      <p id="d2e7728">To study the potential effect of cabin pressure on the measurement quality, we measured calibration gas during a specific descent of the DLR Cessna for about <inline-formula><mml:math id="M596" display="inline"><mml:mn mathvariant="normal">8</mml:mn></mml:math></inline-formula> min covering a pressure change from 820 to <inline-formula><mml:math id="M597" display="inline"><mml:mn mathvariant="normal">880</mml:mn></mml:math></inline-formula> hPa. To study the effect onboard the NASA DC-8, we specifically asked to actively lower the cabin pressure between 840 and <inline-formula><mml:math id="M598" display="inline"><mml:mn mathvariant="normal">760</mml:mn></mml:math></inline-formula> hPa within <inline-formula><mml:math id="M599" display="inline"><mml:mn mathvariant="normal">8</mml:mn></mml:math></inline-formula> min. Figure <xref ref-type="fig" rid="F8"/> shows the retrieved mole fractions of the sampled calibration gas, once plotted against the cabin pressure of the DC-8 and once against the static pressure for the DLR Cessna during the descent. For the ASIA-AQ data no obvious dependencies on the cabin pressure can be identified. The data seems to be stable, as can be seen from the fit of the data with a slope of <inline-formula><mml:math id="M600" display="inline"><mml:mrow><mml:mn mathvariant="normal">1.2497</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> ppb hPa<sup>−1</sup>. For a pressure change in the range of <inline-formula><mml:math id="M602" display="inline"><mml:mn mathvariant="normal">1000</mml:mn></mml:math></inline-formula> hPa, the resulting drift would still almost be within the uncertainty/precision of <inline-formula><mml:math id="M603" display="inline"><mml:mn mathvariant="normal">0.19</mml:mn></mml:math></inline-formula> ppb of the instrument for these <inline-formula><mml:math id="M604" display="inline"><mml:mn mathvariant="normal">8</mml:mn></mml:math></inline-formula> min. However, for the GHGMon flight with the unpressurized cabin a less stable behavior with a standard deviation of <inline-formula><mml:math id="M605" display="inline"><mml:mn mathvariant="normal">0.24</mml:mn></mml:math></inline-formula> ppb can be seen, which is higher than the determined precision for this flight with <inline-formula><mml:math id="M606" display="inline"><mml:mn mathvariant="normal">0.17</mml:mn></mml:math></inline-formula> ppb. The fit function shows a slope of <inline-formula><mml:math id="M607" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1.2238</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> ppb hPa<sup>−1</sup>, but it does not show a clear linear behavior which would indicate a clear dependency on the cabin pressure alone. Another reason for the less stable behavior on the Cessna could be the different sizes of the aircraft. The Cessna is much smaller and is more prone to turbulences and vibrations in general. Especially during acceleration ascending this could have an effect on the data.</p>
      <p id="d2e7861">In Fig. <xref ref-type="fig" rid="F9"/> we also calculated the Allan precision for the cabin pressure experiment during ASIA-AQ in Fig. <xref ref-type="fig" rid="F8"/> on the left. We found the optimal point to be at about <inline-formula><mml:math id="M609" display="inline"><mml:mn mathvariant="normal">13</mml:mn></mml:math></inline-formula> s with an Allan precision of about <inline-formula><mml:math id="M610" display="inline"><mml:mn mathvariant="normal">0.018</mml:mn></mml:math></inline-formula> ppb and this point comes earlier than what we have determined in the ground measurements in Fig. <xref ref-type="fig" rid="F7"/>. However, due to the limited availability of calibration gas during the campaign we were not able to perform a longer experiment for the determination of the stability of the instrument as we did in Fig. <xref ref-type="fig" rid="F7"/> on the ground. Therefore we cannot distinguish if the lower stability in-flight is due to the measurement in-flight itself or due to the cabin pressure changes.</p>

      <fig id="F9"><label>Figure 9</label><caption><p id="d2e7889">Allan precision of the cabin pressure experiment on the DC-8 at ASIA-AQ shown in Fig. <xref ref-type="fig" rid="F8"/> on the left. The optimal point is located at <inline-formula><mml:math id="M611" display="inline"><mml:mrow><mml:mn mathvariant="normal">12.8</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.9</mml:mn></mml:mrow></mml:math></inline-formula> s with an Allan precision of about <inline-formula><mml:math id="M612" display="inline"><mml:mn mathvariant="normal">0.018</mml:mn></mml:math></inline-formula> ppb, about <inline-formula><mml:math id="M613" display="inline"><mml:mn mathvariant="normal">50</mml:mn></mml:math></inline-formula> s earlier than calculated on the ground in Fig. <xref ref-type="fig" rid="F7"/>. However, we cannot distinguish if the instrument is generally less stable in-flight or if this is only the case during cabin pressure change.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f09.png"/>

        </fig>

      <p id="d2e7928">We conclude that the measurements from the unpressurized cabin are less stable but are probably not solely linked to cabin pressure changes alone. Nonetheless, we recommend for both a pressurized and unpressurized cabin to sample calibration gas before and after each relevant ascent or descent in a profile to minimize any drift.</p>
</sec>
<sec id="Ch1.S4.SS3">
  <label>4.3</label><title>Dependency on roll and pitch angle</title>
      <p id="d2e7939">In this section, we analyze if changes in the roll and pitch angle of the aircraft influence the measurements of the MGA<sup>3</sup>. For example, <xref ref-type="bibr" rid="bib1.bibx27" id="text.42"/> introduced a quality flag for their data for roll angles over <inline-formula><mml:math id="M615" display="inline"><mml:mrow><mml:mn mathvariant="normal">10</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">°</mml:mi></mml:mrow></mml:math></inline-formula>, which caused deviations in the measurements due to the centrifugal force acting on the alignments in the laser setup. The roll angle describes the rotation of the aircraft around its longitudinal axis (nose to tail) respective to its initial horizontal position of the wings (positive values: clockwise rotation looking forward) and the pitch angle describes the the rotation of the aircraft around its lateral axis (wing tip to wing tip) respective to its initial horizontal position (positive values: nose up). The roll and pitch angle data were provided by the DC-8 MetNav. The minium and maximum reached values for the roll angle during all flights at the ASIA-AQ campaign were <inline-formula><mml:math id="M616" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">36</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M617" display="inline"><mml:mrow><mml:mn mathvariant="normal">36</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> ° and for the pitch angle <inline-formula><mml:math id="M618" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">8</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M619" display="inline"><mml:mrow><mml:mn mathvariant="normal">15</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> °.</p>

      <fig id="F10" specific-use="star"><label>Figure 10</label><caption><p id="d2e8020">Calibration gas measured in-flight at the ASIA-AQ campaign during changing roll and pitch angles on 26 February and 8 March 2024 in South Korea. On 26 February 2024 we flew a left turn with a roll angle up to <inline-formula><mml:math id="M620" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>30° while the pitch angle was almost constant. On 8 March 2024 we were ascending with a pitch angle of up to 12° while changing from a right turn to a left turn with roll angles from 25 to <inline-formula><mml:math id="M621" display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>15°. In both flights no dependencies that are larger than the respective noise of the measurements could be found.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f10.png"/>

        </fig>

      <p id="d2e8043">In Fig. <xref ref-type="fig" rid="F10"/>, we plotted data of <inline-formula><mml:math id="M622" display="inline"><mml:mn mathvariant="normal">15</mml:mn></mml:math></inline-formula> s from two calibration time windows from the flights on the 26 February and 8 March 2024 against the roll and the pitch angle of the aircraft. For both days we cannot see any clear dependency of the measurements on the angles that are larger than the noise or precision of our measurements. In Fig. <xref ref-type="fig" rid="F11"/>, the left plot shows the standard deviation of N<sub>2</sub>O calculated for each calibration time window of one calibration gas standard plotted against the pitch angle of the DC-8 during ASIA-AQ. The right plot shows the same, but for the roll angle. Each data point in the plot is calculated by roughly <inline-formula><mml:math id="M624" display="inline"><mml:mn mathvariant="normal">12</mml:mn></mml:math></inline-formula> s of data at <inline-formula><mml:math id="M625" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz. For Thailand we calculated a mean value of <inline-formula><mml:math id="M626" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.39</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula> ppb and for the Philippines and South Korea <inline-formula><mml:math id="M627" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.18</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.3</mml:mn></mml:mrow></mml:math></inline-formula> ppb. In both cases no clear dependencies can be seen.</p>

      <fig id="F11"><label>Figure 11</label><caption><p id="d2e8108">Standard deviation of N<sub>2</sub>O for the calibration time windows of one calibration standard plotted against the standard deviation of the pitch angle (left) and the roll angle (right) at the ASIA-AQ campaign. Each data point in the plot is calculated by roughly <inline-formula><mml:math id="M629" display="inline"><mml:mn mathvariant="normal">12</mml:mn></mml:math></inline-formula> s of data. For both kinds of motion no clear dependency can be seen. The mean of the standard deviation values for Thailand is <inline-formula><mml:math id="M630" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.39</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.05</mml:mn></mml:mrow></mml:math></inline-formula> ppb and for the Philippines and South Korea <inline-formula><mml:math id="M631" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.18</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">0.3</mml:mn></mml:mrow></mml:math></inline-formula> ppb.</p></caption>
          <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f11.png"/>

        </fig>

</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Case Studies and example measurements</title>
      <p id="d2e8167">In this section, we present calibrated and water vapor (v1-<inline-formula><mml:math id="M632" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH) corrected N<sub>2</sub>O measurements from the ASIA-AQ campaign. The goal of the campaign is to better understand the air quality in Southeast and East Asia through airborne in-situ measurements that later on can be used for validating models and satellite data <xref ref-type="bibr" rid="bib1.bibx6" id="paren.43"/>. The general approach was to fly the same pattern specifically designed for each country repeatedly for multiple flights to acquire data for large horizontal ranges within the PBL. The flight patterns were repeated two to three times per flight with frequent profiles to scan the whole PBL at different day times. Within a pattern, the profiles were flown at the same locations, as far as possible. With this, we acquired a N<sub>2</sub>O data set with about 100 h of combined data measured at <inline-formula><mml:math id="M635" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz for the regions of Luzon (Northern Philippines), Taiwan, South Korea and Thailand in the winter of 2024. GPS-data and altitude above ground level (AGL) were provided or deduced from the measurements of the DC-8 MetNav. The wind measurements at flight altitude were provided in <inline-formula><mml:math id="M636" display="inline"><mml:mn mathvariant="normal">20</mml:mn></mml:math></inline-formula> Hz by the Meteorological Measurement System (MMS) <xref ref-type="bibr" rid="bib1.bibx39" id="paren.44"/> which is used on multiple NASA aircraft.</p>

      <fig id="F12" specific-use="star"><label>Figure 12</label><caption><p id="d2e8218">Comparison of color coded N<sub>2</sub>O data measured by the MGA<sup>3</sup> in the morning in panel <bold>(a)</bold> and in the afternoon in panel <bold>(b)</bold> of the same flight in South Korea on 17 February 2024. Panel <bold>(c)</bold> depicts the time series for the whole flight measured by the MGA<sup>3</sup> (<inline-formula><mml:math id="M640" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz, precision: <inline-formula><mml:math id="M641" display="inline"><mml:mn mathvariant="normal">0.17</mml:mn></mml:math></inline-formula> ppb) and DACOM (<inline-formula><mml:math id="M642" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> Hz, precision: <inline-formula><mml:math id="M643" display="inline"><mml:mn mathvariant="normal">0.3</mml:mn></mml:math></inline-formula> ppb) and the altitude above ground level showing the frequent ascents and descents. The purple shaded areas show the flight paths over the Yellow Sea in panels <bold>(a)</bold> and <bold>(b)</bold>, where we measured background concentrations of about <inline-formula><mml:math id="M644" display="inline"><mml:mn mathvariant="normal">338</mml:mn></mml:math></inline-formula> ppb in N<sub>2</sub>O. Panel <bold>(d)</bold> shows data from the afternoon over the Yellow Sea where we entered the PBL. The change in water vapor mole fraction while entering seems not to have a significant influence on the water vapor corrected v1-<inline-formula><mml:math id="M646" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH data and the air seems to be clean enough to show no changes in N<sub>2</sub>O compared to the background measurements outside the PBL. The high discrepancies compared to DACOM after 06:00 UTC are attributable to measurement artifacts in the DACOM measurement system due to the implementation of a new detector for N<sub>2</sub>O. Panel <bold>(e)</bold> shows data while entering the PBL over Seoul where enhancements in N<sub>2</sub>O can be seen. Panel <bold>(f)</bold> shows enhancements of up to <inline-formula><mml:math id="M650" display="inline"><mml:mn mathvariant="normal">16</mml:mn></mml:math></inline-formula> ppb in N<sub>2</sub>O between Pyeongtaek and Anseong approaching Osan Airbase which are in good comparison with the DACOM measurements.</p></caption>
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f12.png"/>

      </fig>

      <p id="d2e8375">Figure <xref ref-type="fig" rid="F12"/> presents an example flight from the campaign in South Korea on the 17 February 2024 and shows the variability of N<sub>2</sub>O data as observed on large horizontal scales. Figure <xref ref-type="fig" rid="F12"/>a and b show the flight tracks for the morning and afternoon flights, respectively, color coded by measured N<sub>2</sub>O. The wind barbs indicate southerly to southwesterly winds over the whole flight. In the afternoon (Fig. <xref ref-type="fig" rid="F12"/>b), slightly higher enhancements can be found than in the morning (Fig. <xref ref-type="fig" rid="F12"/>a). Especially, the southerly flight path leading west from the land to the sea shows higher enhancements in the afternoon than in the morning. Those enhancements could be caused by the coal fired KOEN Yeonheung Power Plant on Yeonheung island but also by transport from land due to the mainly southerly winds in the afternoon. The correct source attribution is beyond the scope of this work and will be part of an upcoming study. Figure <xref ref-type="fig" rid="F12"/>c shows the time series of the whole flight with a duration of about <inline-formula><mml:math id="M654" display="inline"><mml:mn mathvariant="normal">7</mml:mn></mml:math></inline-formula> h as measured by the MGA<sup>3</sup> (<inline-formula><mml:math id="M656" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz, precision: <inline-formula><mml:math id="M657" display="inline"><mml:mn mathvariant="normal">0.17</mml:mn></mml:math></inline-formula> ppb) and by DACOM (<inline-formula><mml:math id="M658" display="inline"><mml:mn mathvariant="normal">5</mml:mn></mml:math></inline-formula> Hz, precision: <inline-formula><mml:math id="M659" display="inline"><mml:mn mathvariant="normal">0.3</mml:mn></mml:math></inline-formula> ppb). The grey lines represent the flight altitude above ground level (AGL), showing the frequent level changes and vertical profiles between 0 and <inline-formula><mml:math id="M660" display="inline"><mml:mn mathvariant="normal">2000</mml:mn></mml:math></inline-formula> m. Over the Yellow Sea west of South Korea, indicated by the purple shaded areas, the N<sub>2</sub>O background mole fraction is relatively constant at about <inline-formula><mml:math id="M662" display="inline"><mml:mn mathvariant="normal">338</mml:mn></mml:math></inline-formula> ppb. Here, no significant differences  within and outside the PBL are observed for N<sub>2</sub>O, as shown in more detail in Fig. <xref ref-type="fig" rid="F12"/>d. A change in H<sub>2</sub>O of about <inline-formula><mml:math id="M665" display="inline"><mml:mn mathvariant="normal">0.7</mml:mn></mml:math></inline-formula> % is observed when entering the PBL at <inline-formula><mml:math id="M666" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 900 m during a descent, while the  water vapor corrected N<sub>2</sub>O values remain at the same level. The figure also illustrates the better precision and stability of the DLR-MGA<sup>3</sup> in comparison to the DACOM instrument. The high discrepancies compared to DACOM after 06:00 UTC are attributable to measurement artifacts in the DACOM measurement system due to the implementation of a new detector for N<sub>2</sub>O. In contrast, much higher mole fractions with enhancements of about <inline-formula><mml:math id="M670" display="inline"><mml:mn mathvariant="normal">3</mml:mn></mml:math></inline-formula> ppb compared to the background were measured when entering into the PBL over Seoul (Fig. <xref ref-type="fig" rid="F12"/>e). Finally, Fig. <xref ref-type="fig" rid="F12"/>f illustrates the general good comparison between the MGA<sup>3</sup> data and the DACOM data over larger ranges in N<sub>2</sub>O mole fractions, with enhancements of up to <inline-formula><mml:math id="M673" display="inline"><mml:mn mathvariant="normal">16</mml:mn></mml:math></inline-formula> ppb as measured during a vertical profile taken close to the Osan Airbase.</p>

      <fig id="F13" specific-use="star"><label>Figure 13</label><caption><p id="d2e8578">The 50th and 90th percentile of N<sub>2</sub>O and NH<sub>3</sub> for South Korea, Thailand and Taiwan. For each country data from all flights are taken to calculate the percentile, except for Taiwan, where we have data from one flight only. In Thailand and Taiwan we had to fly higher than in Korea to get out of the PBL due to higher ambient temperatures. In Korea N<sub>2</sub>O and NH<sub>3</sub> show similar behavior. In Thailand the N<sub>2</sub>O shows an increase for altitudes below <inline-formula><mml:math id="M679" display="inline"><mml:mn mathvariant="normal">1500</mml:mn></mml:math></inline-formula> m due to a rain event in one flight, after which the N<sub>2</sub>O emissions were higher over agricultural areas. In general Thailand shows higher enhancements in the PBL for N<sub>2</sub>O due to the higher agricultural activities in this region. In Taiwan an increase in N<sub>2</sub>O around <inline-formula><mml:math id="M683" display="inline"><mml:mn mathvariant="normal">1500</mml:mn></mml:math></inline-formula> m altitude can be seen, which was measured at a technology park at Tainan with manufacturing plants by TSMC.</p></caption>
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f13.png"/>

      </fig>

      <p id="d2e8674">Using the frequent profiles, we can compare the vertical distribution of N<sub>2</sub>O for different regions and also compare it to other species. In the following example, we use NH<sub>3</sub> for comparison, since the agricultural sector is the main anthropogenic source for both species <xref ref-type="bibr" rid="bib1.bibx1" id="paren.45"/>. The NH<sub>3</sub> was measured by the Los Gatos Research Ammonia Analyzer – Trace (LGR-AAT) (<inline-formula><mml:math id="M687" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mi mathvariant="italic">σ</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M688" display="inline"><mml:mn mathvariant="normal">0.1</mml:mn></mml:math></inline-formula> s: <inline-formula><mml:math id="M689" display="inline"><mml:mn mathvariant="normal">0.7</mml:mn></mml:math></inline-formula> ppb)  operated by the Hankuk University of Foreign Stuies (HUFS) and the National Institute of Environmental Research (NIER) in South Korea. In Fig. <xref ref-type="fig" rid="F13"/>a, b and c, by using the data from all flights for South Korea and Thailand respectively and a single flight for Taiwan, we calculate the 50th and 90th percentile for N<sub>2</sub>O (blue and cyan) and NH<sub>3</sub> (red and orange) for <inline-formula><mml:math id="M692" display="inline"><mml:mn mathvariant="normal">100</mml:mn></mml:math></inline-formula> m bins. Each bin has about <inline-formula><mml:math id="M693" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 1000 values except for Taiwan with <inline-formula><mml:math id="M694" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 100. Due to the warmer temperatures in Thailand and Taiwan compared to South Korea, we generally had to fly higher to scan the PBL completely. For the 50th percentile of N<sub>2</sub>O, slightly higher values of 1–2 ppb in Thailand and in Taiwan than in South Korea can be seen for AGL flight altitudes below 1500 and 1000 m, respectively. For the 90th percentile below 1000 m in Thailand, higher values of up to <inline-formula><mml:math id="M696" display="inline"><mml:mn mathvariant="normal">4</mml:mn></mml:math></inline-formula> ppb in N<sub>2</sub>O compared to South Korea and up to <inline-formula><mml:math id="M698" display="inline"><mml:mn mathvariant="normal">2</mml:mn></mml:math></inline-formula> ppb higher than in Taiwan can be seen. One reason for the higher N<sub>2</sub>O values in Thailand compared to South Korea could be the impact of lower temperatures on agriculture in South Korea during February. In general, a reason for the high N<sub>2</sub>O measured over Thailand could be, that we flew over Central Thailand over a plain stretching from Bangkok to Northern Thailand where agriculture is very prominent and concentrated over thousands of square kilometers. Additionally, on the flight of the 21 March 2024, there was a rain event after which N<sub>2</sub>O emission rose in general with enhancements of up to <inline-formula><mml:math id="M702" display="inline"><mml:mn mathvariant="normal">14</mml:mn></mml:math></inline-formula> ppb in that area dominating the higher N<sub>2</sub>O values for the 90th percentile in Thailand. Those enhancements were measured mainly in agricultural areas. In Taiwan, in the 90th percentile a high enhancement of up to <inline-formula><mml:math id="M704" display="inline"><mml:mn mathvariant="normal">6</mml:mn></mml:math></inline-formula> ppb can be seen compared to the background around an altitude of 1000–1700 m. These enhancements with maximum values of <inline-formula><mml:math id="M705" display="inline"><mml:mn mathvariant="normal">15</mml:mn></mml:math></inline-formula> ppb originate mainly from the overflights over a technology park divided between the Anding, Shanhua and Xinshi Districts of Tainan where several plants of semiconductor and chip manufacturers like TSMC are located. Additionally, the technology park is surrounded by agricultural fields and contains a waste water treatment facility making this area complex for source attribution. For NH<sub>3</sub>, we can see that the 90th percentile in South Korea shows structures similar to those of N<sub>2</sub>O. In Taiwan, first, the 50th percentile of NH<sub>3</sub> and the 90th percentile of N<sub>2</sub>O seem to match at the altitudes around <inline-formula><mml:math id="M710" display="inline"><mml:mn mathvariant="normal">1500</mml:mn></mml:math></inline-formula> m, but then the 90th percentile NH<sub>3</sub> seems to diverge more to higher values for altitudes below <inline-formula><mml:math id="M712" display="inline"><mml:mn mathvariant="normal">1500</mml:mn></mml:math></inline-formula> m. For Thailand, NH<sub>3</sub> does not seem to correlate with the N<sub>2</sub>O percentiles, especially not with the 90th percentile, although these enhancements in N<sub>2</sub>O originate mainly from agricultural regions.</p>
      <p id="d2e8952">In an already conducted study by <xref ref-type="bibr" rid="bib1.bibx44" id="text.46"/> at the GHGMon campaign 2023 in the Netherlands, our MGA<sup>3</sup> was used for a N<sub>2</sub>O eddy covariance study, calculating N<sub>2</sub>O fluxes. For a comparison, we applied the same method for specific, representative flux legs across one research flight, once with the v1-<inline-formula><mml:math id="M719" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off water correction and once with the v2 correction, as can be seen in Appendix <xref ref-type="sec" rid="App1.Ch1.S2"/> and Fig. <xref ref-type="fig" rid="FB1"/>. In the comparison, we could find that the relative difference between the results was around <inline-formula><mml:math id="M720" display="inline"><mml:mn mathvariant="normal">3</mml:mn></mml:math></inline-formula> % which is an order of magnitude smaller than the typical relative flux errors reported by <xref ref-type="bibr" rid="bib1.bibx44" id="text.47"/>. Hence, for this instrument setup, we cannot find any significant difference in the influence of the water vapor correction approaches on the calculated eddy covariance fluxes.</p>
</sec>
<sec id="Ch1.S6" sec-type="conclusions">
  <label>6</label><title>Summary and Conclusions</title>
      <p id="d2e9015">In this paper, we evaluate a measurement system for fast (<inline-formula><mml:math id="M721" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> Hz) airborne N<sub>2</sub>O measurements. The core of the system consists of a commercial QCLAS, the Multicompound Gas Analyzer (MGA<sup>3</sup>) from MIRO Analytical AG (Switzerland). The system was successfully deployed twice: during the 2023 GHGMon campaign aboard the DLR Cessna with an unpressurized cabin in the Netherlands, and during the 2024 ASIA-AQ campaign aboard NASA's DC-8 with a pressurized cabin over South Korea, Thailand, the Philippines, and Taiwan. The system is calibrated using a two-point calibration every <inline-formula><mml:math id="M724" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> min, with a high and low standard gas for approximately <inline-formula><mml:math id="M725" display="inline"><mml:mn mathvariant="normal">40</mml:mn></mml:math></inline-formula> s in total, resulting in a duty cycle of about <inline-formula><mml:math id="M726" display="inline"><mml:mn mathvariant="normal">94</mml:mn></mml:math></inline-formula> %. Under this setup, the measuring cell is fully flushed with calibration gas in under <inline-formula><mml:math id="M727" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> s, indicating that the duty cycle could be further increased by reducing the calibration duration.</p>
      <p id="d2e9072">We operate the instrument in the <inline-formula><mml:math id="M728" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-deactivated mode, in which the fitting software freezes the last value used for the width of the spectral profile. By reducing the number of adjustable parameters, this mode decreases the data noise by about <inline-formula><mml:math id="M729" display="inline"><mml:mn mathvariant="normal">42</mml:mn></mml:math></inline-formula> % compared to the default <inline-formula><mml:math id="M730" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-activated setting. However, because the spectral profile widths are strongly influenced by the highly variable H<sub>2</sub>O in the PBL, cross-dependencies on H<sub>2</sub>O remain observable in the data.</p>
      <p id="d2e9114">To correct H<sub>2</sub>O dependencies in both  the <inline-formula><mml:math id="M734" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-deactivated and the <inline-formula><mml:math id="M735" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-activated mode, arising from dilution, line broadening, and other spectroscopic effects, we derived an empirical water vapor correction from laboratory experiments which is specific to our individual MGA<sup>3</sup> model. We further observed that, from flight to flight, the H<sub>2</sub>O measurements show differences relative to NASA's DLH measurements. This is likely due to the inability to perform a two-point calibration of the MGA<sup>3</sup>-H<sub>2</sub>O measurements, as our calibration gases are dry standards. To improve the H<sub>2</sub>O correction, we therefore calibrate the MGA<sup>3</sup>-H<sub>2</sub>O measurements against the DLH data leading to the water vapor corrected version of the MGA<sup>3</sup> data, namely the v1-<inline-formula><mml:math id="M744" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH. Also, we tested a new version of the MGA<sup>3</sup> fitting software, namely v2, that includes a water vapor correction based on the same laboratory experiments. For H<sub>2</sub>O values up to 15 000 ppm, v2 performs comparably to the v1-<inline-formula><mml:math id="M747" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH, showing similar precision (approximately <inline-formula><mml:math id="M748" display="inline"><mml:mn mathvariant="normal">0.17</mml:mn></mml:math></inline-formula> ppb). The v1-<inline-formula><mml:math id="M749" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off-DLH data compares well with N<sub>2</sub>O measurements from NASA's DACOM measured simultaneously with our system at the ASIA-AQ campaign even up to 30 000 ppm H<sub>2</sub>O. In example data from ASIA-AQ we show that clear differences within large horizontal and vertical scales can be distinguished between different regions with high humidity. We also compare the two approaches v1-<inline-formula><mml:math id="M752" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off and v2 using GHGMon campaign data <xref ref-type="bibr" rid="bib1.bibx44" id="paren.48"/> to calculate eddy covariance fluxes, but found no significant difference in the resulting fluxes.</p>
      <p id="d2e9290">We did not observe clear dependencies of the measurements on the aircraft's roll and pitch angles, nor cabin pressure, while sampling calibration gas. However, on the DLR Cessna with its unpressurized cabin, the measurements were generally slightly less stable.</p>
      <p id="d2e9294">We conclude that the presented instrumental setup enables fast and precise airborne N<sub>2</sub>O measurements, suitable for eddy covariance flux estimates and for deployment in highly humid tropical regions.</p>
</sec>

      
      </body>
    <back><app-group>

<app id="App1.Ch1.S1">
  <label>Appendix A</label><title>Dependency of absorption coefficient <inline-formula><mml:math id="M754" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> on water vapor H<sub>2</sub>O</title>
      <p id="d2e9334">The absorption coefficient <inline-formula><mml:math id="M756" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is retrieved from the HITRAN Database 2016 <xref ref-type="bibr" rid="bib1.bibx12" id="paren.49"/>. According to the official HITRAN website at <uri>https://hitran.org/docs/definitions-and-units/</uri> (last access: 14 October 2026) <xref ref-type="bibr" rid="bib1.bibx13" id="paren.50"/>, <inline-formula><mml:math id="M757" display="inline"><mml:mi mathvariant="italic">α</mml:mi></mml:math></inline-formula> is defined as:

          <disp-formula id="App1.Ch1.S1.E18" content-type="numbered"><label>A1</label><mml:math id="M758" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">α</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>,</mml:mo><mml:mi>p</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi>f</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>,</mml:mo><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>,</mml:mo><mml:mi>p</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        where <inline-formula><mml:math id="M759" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the intensity of a spectral line for a single molecule for the transition between two states <inline-formula><mml:math id="M760" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M761" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M762" display="inline"><mml:mi>f</mml:mi></mml:math></inline-formula> the Voigt profile and <inline-formula><mml:math id="M763" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> the wavenumber of the spectral line transition in vacuum. The Voigt profile further consists partially of a normalized Lorentz profile <inline-formula><mml:math id="M764" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> defined as:

          <disp-formula id="App1.Ch1.S1.E19" content-type="numbered"><label>A2</label><mml:math id="M765" display="block"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>,</mml:mo><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>,</mml:mo><mml:mi>p</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mi mathvariant="italic">π</mml:mi></mml:mfrac></mml:mstyle><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>(</mml:mo><mml:mi>p</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>(</mml:mo><mml:mi>p</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced close="]" open="["><mml:mrow><mml:mi mathvariant="italic">ν</mml:mi><mml:mo>-</mml:mo><mml:msubsup><mml:mi mathvariant="italic">ν</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow><mml:mo>∗</mml:mo></mml:msubsup><mml:mo>(</mml:mo><mml:mi>p</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

        Here <inline-formula><mml:math id="M766" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">ν</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow><mml:mo>∗</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> is the pressure shift corrected wavenumber <inline-formula><mml:math id="M767" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M768" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula> is the Lorentzian Half-Width-Half-Maximum (HWHM) width of the line shape. In the case of pressure broadening on the observed species induced by air, water vapor and the species itself, the resulting width <inline-formula><mml:math id="M769" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula> is defined as (<xref ref-type="bibr" rid="bib1.bibx20" id="altparen.51"/>; <uri>https://hitran.org/docs/definitions-and-units/</uri>):

          <disp-formula id="App1.Ch1.S1.E20" content-type="numbered"><label>A3</label><mml:math id="M770" display="block"><mml:mrow><mml:mtable class="split" rowspacing="0.2ex" displaystyle="true" columnalign="right left"><mml:mtr><mml:mtd><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>(</mml:mo><mml:mi>p</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mo>=</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow><mml:mi>T</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mrow><mml:msub><mml:mi>n</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:msup><mml:mfenced open="(" close=""><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mfenced open="(" close=")"><mml:mrow><mml:mi>p</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">self</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfenced></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:mfenced open="" close=")"><mml:mrow><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">self</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">self</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:mrow></mml:math></disp-formula>

        Here <inline-formula><mml:math id="M771" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M772" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">self</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M773" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> are the HWHM induced by the partial pressures <inline-formula><mml:math id="M774" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M775" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M776" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">self</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of air, water vapor and the species itself at a reference temperature <inline-formula><mml:math id="M777" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">296</mml:mn></mml:mrow></mml:math></inline-formula> K and pressure <inline-formula><mml:math id="M778" display="inline"><mml:mrow><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> atm.</p>
      <p id="d2e9935">Specifically for the N<sub>2</sub>O absorption line used in our MGA<sup>3</sup>, the HITRAN data base shows that H<sub>2</sub>O has a higher broadening effect than air (<inline-formula><mml:math id="M782" display="inline"><mml:mo lspace="0mm">=</mml:mo></mml:math></inline-formula> nitrogen (N<sub>2</sub>), oxygen (O<sub>2</sub>)) and N<sub>2</sub>O itself with <inline-formula><mml:math id="M786" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.1308</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M787" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.0701</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M788" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">self</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.085</mml:mn></mml:mrow></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx13" id="paren.52"/>. The difference between <inline-formula><mml:math id="M789" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">self</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M790" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">N</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> has important implications on the spectral line width. While the global background concentration of N<sub>2</sub>O in the troposphere is in the range of about <inline-formula><mml:math id="M792" display="inline"><mml:mn mathvariant="normal">338</mml:mn></mml:math></inline-formula> ppb, H<sub>2</sub>O mole fractions lie between 1 to <inline-formula><mml:math id="M794" display="inline"><mml:mn mathvariant="normal">10</mml:mn></mml:math></inline-formula> ppm even in the dry stratosphere, but can get specifically high in regions such as the tropical boundary layer  (up to 30 000 ppm, which is 4 to 5 orders of magnitudes higher than for N<sub>2</sub>O. With this, we can simplify Eq. (<xref ref-type="disp-formula" rid="App1.Ch1.S1.E20"/>) for measurements in the troposphere to:

          <disp-formula id="App1.Ch1.S1.E21" content-type="numbered"><label>A4</label><mml:math id="M796" display="block"><mml:mtable rowspacing="0.2ex" class="split" displaystyle="true" columnalign="right left"><mml:mtr><mml:mtd><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>(</mml:mo><mml:mi>p</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mo>=</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow><mml:mi>T</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mrow><mml:msub><mml:mi>n</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub></mml:mrow></mml:msup><mml:mfenced close="" open="("><mml:mrow><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mi mathvariant="normal">air</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:mfenced close=")" open="("><mml:mrow><mml:mi>p</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfenced></mml:mrow></mml:mtd></mml:mtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:mfenced close=")" open=""><mml:mrow><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">γ</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub><mml:mo>)</mml:mo><mml:msub><mml:mi>p</mml:mi><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">H</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mi mathvariant="normal">O</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>

        Therefore, we assume the width <inline-formula><mml:math id="M797" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula> of our measured line spectra to be mainly dependent on water vapor for atmospheric measurements in the troposphere, assuming that <inline-formula><mml:math id="M798" display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M799" display="inline"><mml:mi>p</mml:mi></mml:math></inline-formula> are constant in the cell.</p>
</app>

<app id="App1.Ch1.S2">
  <label>Appendix B</label><title>N<sub>2</sub>O Eddy Covariance GHGMon</title>
      <p id="d2e10297"><xref ref-type="bibr" rid="bib1.bibx44" id="text.53"/> used the same MGA<sup>3</sup> as presented in our study to conduct airborne eddy covariance flux measurements in the course of the GHGMon (Greenhouse Gas Monitoring) campaign 2023 in the Netherlands. Precise high-frequency GHG measurements without interference from water vapor related effects are a prerequisite for robust flux measurements, as water vapor mole fractions are often quite distinct between turbulent updrafts and downdrafts, potentially falsifying GHG measurements if not properly corrected. In order to investigate the extent to which different water vapor correction approaches affect flux measurements, we applied both, the v1-<inline-formula><mml:math id="M802" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off water correction and the v2 correction to specific, representative flux legs across one research flight of the study of <xref ref-type="bibr" rid="bib1.bibx44" id="text.54"/>.</p>

      <fig id="FB1" specific-use="star"><label>Figure B1</label><caption><p id="d2e10323">Panel <bold>(a)</bold> presents vertical wind measurements from a flight on 21 June 2023 in the Netherlands. Panel <bold>(b)</bold> shows corresponding H<sub>2</sub>O measurements. Panel <bold>(c)</bold> shows the water vapor corrected N<sub>2</sub>O measurements, once retrieved with v1-<inline-formula><mml:math id="M805" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off and once with v2. Panel <bold>(d)</bold> shows the calculated eddy covariance fluxes from the respective time series in panel <bold>(c)</bold>, error bars depicting the uncertainty associated with the flux computation.</p></caption>
        <graphic xlink:href="https://amt.copernicus.org/articles/19/6583/2026/amt-19-6583-2026-f14.png"/>

      </fig>

      <p id="d2e10373">In Fig. <xref ref-type="fig" rid="FB1"/>a and b, we can see the vertical wind measurements and the H<sub>2</sub>O measurements of the METPOD system on the DLR Cessna from a flight in Friesland on 21 June 2023. Both show high-frequency fluctuations, typical during fair-weather turbulent conditions, which in turn are fundamental for applying the eddy covariance methodology. In Fig. <xref ref-type="fig" rid="FB1"/>c, we see the MGA<sup>3</sup>-N<sub>2</sub>O measurements for the v1-<inline-formula><mml:math id="M809" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off and v2 water correction approaches, similarly showing high-frequency variability expected in the turbulent PBL. In Fig. <xref ref-type="fig" rid="FB1"/>d, the calculated eddy covariance fluxes are shown as time series for the two retrieved mole fractions from Fig. <xref ref-type="fig" rid="FB1"/>c, calculated according to the procedure presented in <xref ref-type="bibr" rid="bib1.bibx44" id="text.55"/>. The mean value for the fluxes over the given time frame is slightly higher for the fluxes with the v2 water correction (<inline-formula><mml:math id="M810" display="inline"><mml:mn mathvariant="normal">0.36</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M811" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<sup>−2</sup> s<sup>−1</sup>) compared to the fluxes with the v1-<inline-formula><mml:math id="M814" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off water correction (<inline-formula><mml:math id="M815" display="inline"><mml:mn mathvariant="normal">0.33</mml:mn></mml:math></inline-formula> <inline-formula><mml:math id="M816" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<sup>−2</sup> s<sup>−1</sup>), which translates to a relative difference of <inline-formula><mml:math id="M819" display="inline"><mml:mn mathvariant="normal">9</mml:mn></mml:math></inline-formula> %. This difference is expected, given the drift in N<sub>2</sub>O corrected according to v2, with increasing H<sub>2</sub>O (see Sect. <xref ref-type="sec" rid="Ch1.S3.SS4"/>). However, the relative difference (<inline-formula><mml:math id="M822" display="inline"><mml:mn mathvariant="normal">9</mml:mn></mml:math></inline-formula> %) is approximately 1 order of magnitude smaller than typical relative flux errors reported in <xref ref-type="bibr" rid="bib1.bibx44" id="text.56"/>, which range between 30 %–100 %, which are superimposed as error bars for the v1-<inline-formula><mml:math id="M823" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off fluxes in Fig. <xref ref-type="fig" rid="FB1"/>d. For both corrections, we computed the limit of detection of N<sub>2</sub>O fluxes, which was found to be slightly higher for the v2 water correction with 0.028 <inline-formula><mml:math id="M825" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<sup>−2</sup> s<sup>−1</sup> compared to 0.017 <inline-formula><mml:math id="M828" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>g m<sup>−2</sup> s<sup>−1</sup> for v1-<inline-formula><mml:math id="M831" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-off. Given that the differences in fluxes derived with both water vapor corrections is one order of magnitude smaller than typical flux errors, we conclude that the choice of water correction approaches is not a limiting factor for the quality of such flux measurements, but have to be considered when corresponding systems should be improved or small fluxes close to the detection limits are to be measured. We note explicitly that these conclusions are only valid for the comparison of the water vapor corrections presented within this work, and do not represent differences in fluxes calculated with mole fraction measurements with and without water vapor correction.</p>
</app>
  </app-group><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d2e10641">The data are available from the author upon request. All of the ASIA-AQ campaign data is available on the archive: <uri>https://www-air.larc.nasa.gov/cgi-bin/ArcView/asiaaq</uri> (last access: 14 October 2026) (<ext-link xlink:href="https://doi.org/10.5067/SUBORBITAL/ASIA-AQ/DATA001" ext-link-type="DOI">10.5067/SUBORBITAL/ASIA-AQ/DATA001</ext-link>, <xref ref-type="bibr" rid="bib1.bibx6" id="altparen.57"/>)</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d2e10656">LK wrote the paper, did the analysis and prepared the figures. LK and ME prepared the MGA<sup>3</sup> instrument for ASIA-AQ. LK, ME, PW and AR operated the instrument at GHGMon and ASIA-AQ and conducted the measurements. AF and MP contributed to the manuscript and discussion. OA provided the new v2 software for the MGA<sup>3</sup>. GD, JD, YH and JM operated the DACOM and DLH instruments at ASIA-AQ and provided the respective data and also provided altitude above ground level data for the DC-8 at ASIA-AQ. RB, CG, JDD and RP provided GPS-data, wind measurements, static pressure measurements, cabin pressure measurements and roll and pitch angle data from the DC-8 at ASIA-AQ. GL and JK provided the LGR-NH<sub>3</sub> measurements at ASIA-AQ. All authors contributed to the manuscript and the discussion.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d2e10689">The contact author has declared that none of the authors has any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d2e10695">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. The authors bear the ultimate responsibility for providing appropriate place names. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.</p>
  </notes><ack><title>Acknowledgements</title><p id="d2e10701">The authors thank the ASIA-AQ mission management, NASA ESPO, the AFRC DC-8 Team, and all ASIA-AQ participants and colleagues for making this campaign and these measurements possible and for the productive and valuable discussions during the campaign and after.</p></ack><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d2e10706">This paper was edited by Hendrik Fuchs and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Behera et al.(2013)</label><mixed-citation>Behera, S. N., Sharma, M., Aneja, V. P., and Balasubramanian, R.: Ammonia in the atmosphere: a review on emission sources, atmospheric chemistry and deposition on terrestrial bodies, Environmental Science and Pollution Research International, 20, 8092–8131, <ext-link xlink:href="https://doi.org/10.1007/s11356-013-2051-9" ext-link-type="DOI">10.1007/s11356-013-2051-9</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Capasso(2010)</label><mixed-citation>Capasso, F.: High-performance midinfrared quantum cascade lasers, Opt. Eng., 49, 111102, <ext-link xlink:href="https://doi.org/10.1117/1.3505844" ext-link-type="DOI">10.1117/1.3505844</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>CCAC(2024)</label><mixed-citation>CCAC: Global Nitrous Oxide Assessment – Supplementary Information,   Global Nitrous Oxide Assessment report, <uri>https://www.ccacoalition.org/resources/global-nitrous-oxide-assessment</uri> (last access: 8 September 2025), 2024.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Chadwick et al.(2014)</label><mixed-citation>Chadwick, D. R., Cardenas, L., Misselbrook, T. H., Smith, K. A., Rees, R. M., Watson, C. J., McGeough, K. L., Williams, J. R., Cloy, J. M., Thorman, R. E., and Dhanoa, M. S.: Optimizing chamber methods for measuring nitrous oxide emissions from plot–based agricultural experiments, Eur. J. Soil Sci., 65, 295–307, <ext-link xlink:href="https://doi.org/10.1111/ejss.12117" ext-link-type="DOI">10.1111/ejss.12117</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Chen et al.(2010)</label><mixed-citation>Chen, H., Winderlich, J., Gerbig, C., Hoefer, A., Rella, C. W., Crosson, E. R., Van Pelt, A. D., Steinbach, J., Kolle, O., Beck, V., Daube, B. C., Gottlieb, E. W., Chow, V. Y., Santoni, G. W., and Wofsy, S. C.: High-accuracy continuous airborne measurements of greenhouse gases (CO<sub>2</sub> and CH<sub>4</sub>) using the cavity ring-down spectroscopy (CRDS) technique, Atmos. Meas. Tech., 3, 375–386, <ext-link xlink:href="https://doi.org/10.5194/amt-3-375-2010" ext-link-type="DOI">10.5194/amt-3-375-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Crawford et al.(2025)</label><mixed-citation>Crawford, J., Lefer, B., Zavaleta, J. R., Adachi, K., Apel, E., Bennett, J. R., Blake, D., Caulton, D., Dibb, J., Digangi, J. P., Diskin, G. S., Franchin, A., Gatebe, C. K., Hall, S., Huey, G., Jimenez, J.-L., Jordan, C., Kim, S., Lee, G., Lee, H., Lee, T., Lim, S., Miech, J., Min, K.-E., Moore, R., Roiger, A., Silverman, M., St. Clair, J., Wennberg, P., Wisthaler, A., Wolfe, G., Yum, S. S., and Zondlo: Airborne and Satellite Investigation of Asian Air Quality Campaign Data, NASA Langley Atmospheric Science Data Center Distributed Active Archive Center [data set], <ext-link xlink:href="https://doi.org/10.5067/SUBORBITAL/ASIA-AQ/DATA001" ext-link-type="DOI">10.5067/SUBORBITAL/ASIA-AQ/DATA001</ext-link>, 2025.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Dacic et al.(2024)</label><mixed-citation>Dacic, N., Plant, G., and Kort, E. A.: Airborne Measurements Reveal High Spatiotemporal Variation and the Heavy–Tail Characteristic of Nitrous Oxide Emissions in Iowa, J. Geophys. Res.-Atmos., 129, <ext-link xlink:href="https://doi.org/10.1029/2024JD041403" ext-link-type="DOI">10.1029/2024JD041403</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Davidson and Kanter(2014)</label><mixed-citation>Davidson, E. A. and Kanter, D.: Inventories and scenarios of nitrous oxide emissions, Environ. Res. Lett., 9, 105012, <ext-link xlink:href="https://doi.org/10.1088/1748-9326/9/10/105012" ext-link-type="DOI">10.1088/1748-9326/9/10/105012</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Del Grosso et al.(2022)</label><mixed-citation>Del Grosso, S. J., Ogle, S. M., Nevison, C., Gurung, R., Parton, W. J., Wagner-Riddle, C., Smith, W., Winiwarter, W., Grant, B., Tenuta, M., Marx, E., Spencer, S., and Williams, S.: A gap in nitrous oxide emission reporting complicates long-term climate mitigation, P. Natl. Acad. Sci. USA, 119, e2200354119, <ext-link xlink:href="https://doi.org/10.1073/pnas.2200354119" ext-link-type="DOI">10.1073/pnas.2200354119</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Diskin et al.(2002)</label><mixed-citation>Diskin, G. S., Podolske, J. R., Sachse, G. W., and Slate, T. A.: Open-path airborne tunable diode laser hygrometer, in: Diode Lasers and Applications in Atmospheric Sensing, edited by: Fried, A., SPIE Proceedings, p. 196, SPIE, <ext-link xlink:href="https://doi.org/10.1117/12.453736" ext-link-type="DOI">10.1117/12.453736</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Eckl et al.(2021)</label><mixed-citation>Eckl, M., Roiger, A., Kostinek, J., Fiehn, A., Huntrieser, H., Knote, C., Barkley, Z. R., Ogle, S. M., Baier, B. C., Sweeney, C., and Davis, K. J.: Quantifying Nitrous Oxide Emissions in the U.S. Midwest: A Top–Down Study Using High Resolution Airborne In–Situ Observations, Geophys. Res. Lett., 48, <ext-link xlink:href="https://doi.org/10.1029/2020GL091266" ext-link-type="DOI">10.1029/2020GL091266</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Gordon et al.(2017)</label><mixed-citation>Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., Drouin, B. J., Flaud, J.-M., Gamache, R. R., Hodges, J. T., Jacquemart, D., Perevalov, V. I., Perrin, A., Shine, K. P., Smith, M.-A., Tennyson, J., Toon, G. C., Tran, H., Tyuterev, V. G., Barbe, A., Császár, A. G., Devi, V. M., Furtenbacher, T., Harrison, J. J., Hartmann, J.-M., Jolly, A., Johnson, T. J., Karman, T., Kleiner, I., Kyuberis, A. A., Loos, J., Lyulin, O. M., Massie, S. T., Mikhailenko, S. N., Moazzen-Ahmadi, N., Müller, H., Naumenko, O. V., Nikitin, A. V., Polyansky, O. L., Rey, M., Rotger, M., Sharpe, S. W., Sung, K., Starikova, E., Tashkun, S. A., Auwera, J. V., Wagner, G., Wilzewski, J., Wcisło, P., Yu, S., and Zak, E. J.: The HITRAN2016 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 203, 3–69, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2017.06.038" ext-link-type="DOI">10.1016/j.jqsrt.2017.06.038</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Gordon et al.(2022)</label><mixed-citation>Gordon, I. E., Rothman, L. S., Hargreaves, R. J., Hashemi, R., Karlovets, E. V., Skinner, F. M., Conway, E. K., Hill, C., Kochanov, R. V., Tan, Y., Wcisło, P., Finenko, A. A., Nelson, K., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., Coustenis, A., Drouin, B. J., Flaud, J.-M., Gamache, R. R., Hodges, J. T., Jacquemart, D., Mlawer, E. J., Nikitin, A. V., Perevalov, V. I., Rotger, M., Tennyson, J., Toon, G. C., Tran, H., Tyuterev, V. G., Adkins, E. M., Baker, A., Barbe, A., Canè, E., Császár, A. G., Dudaryonok, A., Egorov, O., Fleisher, A. J., Fleurbaey, H., Foltynowicz, A., Furtenbacher, T., Harrison, J. J., Hartmann, J.-M., Horneman, V.-M., Huang, X., Karman, T., Karns, J., Kassi, S., Kleiner, I., Kofman, V., Kwabia-Tchana, F., Lavrentieva, N. N., Lee, T. J., Long, D. A., Lukashevskaya, A. A., Lyulin, O. M., Makhnev, V., Matt, W., Massie, S. T., Melosso, M., Mikhailenko, S. N., Mondelain, D., Müller, H., Naumenko, O. V., Perrin, A., Polyansky, O. L., Raddaoui, E., Raston, P. L., Reed, Z. D., Rey, M., Richard, C., Tóbiás, R., Sadiek, I., Schwenke, D. W., Starikova, E., Sung, K., Tamassia, F., Tashkun, S. A., Vander Auwera, J., Vasilenko, I. A., Vigasin, A. A., Villanueva, G. L., Vispoel, B., Wagner, G., Yachmenev, A., and Yurchenko, S. N.: The HITRAN2020 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 277, 107949, <ext-link xlink:href="https://doi.org/10.1016/j.jqsrt.2021.107949" ext-link-type="DOI">10.1016/j.jqsrt.2021.107949</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Gvakharia et al.(2018)</label><mixed-citation>Gvakharia, A., Kort, E. A., Smith, M. L., and Conley, S.: Testing and evaluation of a new airborne system for continuous N<sub>2</sub>O, CO<sub>2</sub>, CO, and H<sub>2</sub>O measurements: the Frequent Calibration High-performance Airborne Observation System (FCHAOS), Atmos. Meas. Tech., 11, 6059–6074, <ext-link xlink:href="https://doi.org/10.5194/amt-11-6059-2018" ext-link-type="DOI">10.5194/amt-11-6059-2018</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Gvakharia et al.(2020)</label><mixed-citation>Gvakharia, A., Kort, E. A., Smith, M. L., and Conley, S.: Evaluating Cropland N2O Emissions and Fertilizer Plant Greenhouse Gas Emissions With Airborne Observations, J. Geophys. Res.-Atmos., 125, <ext-link xlink:href="https://doi.org/10.1029/2020JD032815" ext-link-type="DOI">10.1029/2020JD032815</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Hundt et al.(2018)</label><mixed-citation>Hundt, P. M., Tuzson, B., Aseev, O., Liu, C., Scheidegger, P., Looser, H., Kapsalidis, F., Shahmohammadi, M., Faist, J., and Emmenegger, L.: Multi-species trace gas sensing with dual-wavelength QCLs, Appl. Phys. B, 124, <ext-link xlink:href="https://doi.org/10.1007/s00340-018-6977-y" ext-link-type="DOI">10.1007/s00340-018-6977-y</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Kanter et al.(2020)</label><mixed-citation>Kanter, D. R., Ogle, S. M., and Winiwarter, W.: Building on Paris: integrating nitrous oxide mitigation into future climate policy, Current Opinion in Environmental Sustainability, 47, 7–12, <ext-link xlink:href="https://doi.org/10.1016/j.cosust.2020.04.005" ext-link-type="DOI">10.1016/j.cosust.2020.04.005</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Kaufmann et al.(2016)</label><mixed-citation>Kaufmann, S., Voigt, C., Jurkat, T., Thornberry, T., Fahey, D. W., Gao, R.-S., Schlage, R., Schäuble, D., and Zöger, M.: The airborne mass spectrometer AIMS – Part 1: AIMS-H<sub>2</sub>O for UTLS water vapor measurements, Atmos. Meas. Tech., 9, 939–953, <ext-link xlink:href="https://doi.org/10.5194/amt-9-939-2016" ext-link-type="DOI">10.5194/amt-9-939-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>Kiemle et al.(2024)</label><mixed-citation>Kiemle, C., Fix, A., Fruck, C., Ehret, G., and Wirth, M.: Design study for an airborne N<sub>2</sub>O lidar, Atmos. Meas. Tech., 17, 6569–6578, <ext-link xlink:href="https://doi.org/10.5194/amt-17-6569-2024" ext-link-type="DOI">10.5194/amt-17-6569-2024</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Kostinek et al.(2019)</label><mixed-citation>Kostinek, J., Roiger, A., Davis, K. J., Sweeney, C., DiGangi, J. P., Choi, Y., Baier, B., Hase, F., Groß, J., Eckl, M., Klausner, T., and Butz, A.: Adaptation and performance assessment of a quantum and interband cascade laser spectrometer for simultaneous airborne in situ observation of CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, CO<sub>2</sub>, CO and N<sub>2</sub>O, Atmos. Meas. Tech., 12, 1767–1783, <ext-link xlink:href="https://doi.org/10.5194/amt-12-1767-2019" ext-link-type="DOI">10.5194/amt-12-1767-2019</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Lebegue et al.(2016)</label><mixed-citation>Lebegue, B., Schmidt, M., Ramonet, M., Wastine, B., Yver Kwok, C., Laurent, O., Belviso, S., Guemri, A., Philippon, C., Smith, J., and Conil, S.: Comparison of nitrous oxide (N<sub>2</sub>O) analyzers for high-precision measurements of atmospheric mole fractions, Atmos. Meas. Tech., 9, 1221–1238, <ext-link xlink:href="https://doi.org/10.5194/amt-9-1221-2016" ext-link-type="DOI">10.5194/amt-9-1221-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Li et al.(2013)</label><mixed-citation>Li, J. S., Chen, W., and Fischer, H.: Quantum Cascade Laser Spectrometry Techniques: A New Trend in Atmospheric Chemistry, Appl. Spectrosc. Rev., 48, 523–559, <ext-link xlink:href="https://doi.org/10.1080/05704928.2012.757232" ext-link-type="DOI">10.1080/05704928.2012.757232</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Lopez et al.(2012)</label><mixed-citation>Lopez, M., Schmidt, M., Yver, C., Messager, C., Worthy, D., Kazan, V., Ramonet, M., Bousquet, P., and Ciais, P.: Seasonal variation of N2O emissions in France inferred from atmospheric N2O and 222Rn measurements, J. Geophys. Res.-Atmos., 117, <ext-link xlink:href="https://doi.org/10.1029/2012JD017703" ext-link-type="DOI">10.1029/2012JD017703</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx24"><label>MacFarling Meure et al.(2006)</label><mixed-citation>MacFarling Meure, C., Etheridge, D., Trudinger, C., Steele, P., Langenfelds, R., van Ommen, T., Smith, A., and Elkins, J.: Law Dome CO2, CH4 and N2O ice core records extended to 2000 years BP, Geophys. Res. Lett., 33, <ext-link xlink:href="https://doi.org/10.1029/2006GL026152" ext-link-type="DOI">10.1029/2006GL026152</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Myhre et al.(2013)</label><mixed-citation>Myhre, G., Shindell, D., Bréon, F.-M., Collins, W., Fuglestvedt, J., Huang, J., Koch, D., Lamarque, J.-F., Lee, D., Mendoza, B., Nakajima, T., Robock, A., Stephens, G., Takemura, T., and Zhang, H.: Anthropogenic and Natural Radiative Forcing, in: Climate Change 2013: The Physical Science Basis. Contribution of Working Group I to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change, edited by: Stocker, T. F., Qin, D., Plattner, G.-K., Tignor, M., Allen, S. K., Boschung, J., Nauels, A., Xia, Y., Bex, V., and Midgley, P. M., Cambridge University Press, Cambridge, United Kingdom and New York, NY, USA, 659–740, <ext-link xlink:href="https://doi.org/10.1017/CBO9781107415324.018" ext-link-type="DOI">10.1017/CBO9781107415324.018</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Pattey et al.(2007)</label><mixed-citation>Pattey, E., Edwards, G. C., Desjardins, R. L., Pennock, D. J., Smith, W., Grant, B., and MacPherson, J. I.: Tools for quantifying N2O emissions from agroecosystems, Agr. Forest Meteorol., 142, 103–119, <ext-link xlink:href="https://doi.org/10.1016/j.agrformet.2006.05.013" ext-link-type="DOI">10.1016/j.agrformet.2006.05.013</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Pitt et al.(2016)</label><mixed-citation>Pitt, J. R., Le Breton, M., Allen, G., Percival, C. J., Gallagher, M. W., Bauguitte, S. J.-B., O'Shea, S. J., Muller, J. B. A., Zahniser, M. S., Pyle, J., and Palmer, P. I.: The development and evaluation of airborne in situ N2O and CH4 sampling using a quantum cascade laser absorption spectrometer (QCLAS), Atmos. Meas. Tech., 9, 63–77, <ext-link xlink:href="https://doi.org/10.5194/amt-9-63-2016" ext-link-type="DOI">10.5194/amt-9-63-2016</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx28"><label>Prather and Wilson(2026)</label><mixed-citation>Prather, M. J. and Wilson, C. P.: Projecting nitrous oxide over the 21st century, uncertainty related to stratospheric loss, P. Natl. Acad. Sci. USA, 123, e2524123123, <ext-link xlink:href="https://doi.org/10.1073/pnas.2524123123" ext-link-type="DOI">10.1073/pnas.2524123123</ext-link>, 2026.</mixed-citation></ref>
      <ref id="bib1.bibx29"><label>Prather et al.(2015)</label><mixed-citation>Prather, M. J., Hsu, J., DeLuca, N. M., Jackman, C. H., Oman, L. D., Douglass, A. R., Fleming, E. L., Strahan, S. E., Steenrod, S. D., Søvde, O. A., Isaksen, I. S. A., Froidevaux, L., and Funke, B.: Measuring and modeling the lifetime of nitrous oxide including its variability, J. Geophys. Res.-Atmos., 120, 5693–5705, <ext-link xlink:href="https://doi.org/10.1002/2015JD023267" ext-link-type="DOI">10.1002/2015JD023267</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx30"><label>Prather et al.(2023)</label><mixed-citation>Prather, M. J., Froidevaux, L., and Livesey, N. J.: Observed changes in stratospheric circulation: decreasing lifetime of N<sub>2</sub>O, 2005–2021, Atmos. Chem. Phys., 23, 843–849, <ext-link xlink:href="https://doi.org/10.5194/acp-23-843-2023" ext-link-type="DOI">10.5194/acp-23-843-2023</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx31"><label>Rapson and Dacres(2014)</label><mixed-citation>Rapson, T. D. and Dacres, H.: Analytical techniques for measuring nitrous oxide, TrAC-Trend. Anal. Chem., 54, 65–74, <ext-link xlink:href="https://doi.org/10.1016/j.trac.2013.11.004" ext-link-type="DOI">10.1016/j.trac.2013.11.004</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx32"><label>Ravishankara et al.(2009)</label><mixed-citation>Ravishankara, A. R., Daniel, J. S., and Portmann, R. W.: Nitrous oxide (N2O): the dominant ozone-depleting substance emitted in the 21st century, Science, 326, 123–125, <ext-link xlink:href="https://doi.org/10.1126/science.1176985" ext-link-type="DOI">10.1126/science.1176985</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx33"><label>Reay et al.(2012)</label><mixed-citation>Reay, D. S., Davidson, E. A., Smith, K. A., Smith, P., Melillo, J. M., Dentener, F., and Crutzen, P. J.: Global agriculture and nitrous oxide emissions, Nature Climate Change, 2, 410–416, <ext-link xlink:href="https://doi.org/10.1038/nclimate1458" ext-link-type="DOI">10.1038/nclimate1458</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx34"><label>Rella et al.(2013)</label><mixed-citation>Rella, C. W., Chen, H., Andrews, A. E., Filges, A., Gerbig, C., Hatakka, J., Karion, A., Miles, N. L., Richardson, S. J., Steinbacher, M., Sweeney, C., Wastine, B., and Zellweger, C.: High accuracy measurements of dry mole fractions of carbon dioxide and methane in humid air, Atmos. Meas. Tech., 6, 837–860, <ext-link xlink:href="https://doi.org/10.5194/amt-6-837-2013" ext-link-type="DOI">10.5194/amt-6-837-2013</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx35"><label>Rogelj and Lamboll(2024)</label><mixed-citation>Rogelj, J. and Lamboll, R. D.: Substantial reductions in non-CO2 greenhouse gas emissions reductions implied by IPCC estimates of the remaining carbon budget, Commun. Earth Environ., 5, <ext-link xlink:href="https://doi.org/10.1038/s43247-023-01168-8" ext-link-type="DOI">10.1038/s43247-023-01168-8</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bibx36"><label>Saboya et al.(2024)</label><mixed-citation>Saboya, E., Manning, A. J., Levy, P., Stanley, K. M., Pitt, J., Young, D., Say, D., Grant, A., Arnold, T., Rennick, C., Tomlinson, S. J., Carnell, E. J., Artioli, Y., Stavert, A., Spain, T. G., O'Doherty, S., Rigby, M., and Ganesan, A. L.: Combining Top–Down and Bottom–Up Approaches to Evaluate Recent Trends and Seasonal Patterns in UK N2O Emissions, J. Geophys. Res.-Atmos., 129, <ext-link xlink:href="https://doi.org/10.1029/2024JD040785" ext-link-type="DOI">10.1029/2024JD040785</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bibx37"><label>Sachse et al.(1987)</label><mixed-citation>Sachse, G. W., Hill, G. F., Wade, L. O., and Perry, M. G.: Fast–response, high–precision carbon monoxide sensor using a tunable diode laser absorption technique, J. Geophys. Res.-Atmos., 92, 2071–2081, <ext-link xlink:href="https://doi.org/10.1029/JD092iD02p02071" ext-link-type="DOI">10.1029/JD092iD02p02071</ext-link>, 1987.</mixed-citation></ref>
      <ref id="bib1.bibx38"><label>Schiller et al.(2008)</label><mixed-citation>Schiller, C. L., Bozem, H., Gurk, C., Parchatka, U., Königstedt, R., Harris, G. W., Lelieveld, J., and Fischer, H.: Applications of quantum cascade lasers for sensitive trace gas measurements of CO, CH4, N2O and HCHO, Appl. Phys. B, 92, 419–430, <ext-link xlink:href="https://doi.org/10.1007/s00340-008-3125-0" ext-link-type="DOI">10.1007/s00340-008-3125-0</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx39"><label>Scott et al.(1990)</label><mixed-citation>Scott, S. G., Bui, T. P., Chan, K. R., and Bowen, S. W.: The Meteorological Measurement System on the NASA ER-2 Aircraft, J. Atmos. Ocean. Tech., 7, 525–540, <ext-link xlink:href="https://doi.org/10.1175/1520-0426(1990)007&lt;0525:TMMSOT&gt;2.0.CO;2" ext-link-type="DOI">10.1175/1520-0426(1990)007&lt;0525:TMMSOT&gt;2.0.CO;2</ext-link>, 1990.</mixed-citation></ref>
      <ref id="bib1.bibx40"><label>Smith(2017)</label><mixed-citation>Smith, K. A.: Changing views of nitrous oxide emissions from agricultural soil: key controlling processes and assessment at different spatial scales, Eur. J. Soil Sci., 68, 137–155, <ext-link xlink:href="https://doi.org/10.1111/ejss.12409" ext-link-type="DOI">10.1111/ejss.12409</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx41"><label>Thompson et al.(2019)</label><mixed-citation>Thompson, R. L., Lassaletta, L., Patra, P. K., Wilson, C., Wells, K. C., Gressent, A., Koffi, E. N., Chipperfield, M. P., Winiwarter, W., Davidson, E. A., Tian, H., and Canadell, J. G.: Acceleration of global N2O emissions seen from two decades of atmospheric inversion, Nature Climate Change, 9, 993–998, <ext-link xlink:href="https://doi.org/10.1038/s41558-019-0613-7" ext-link-type="DOI">10.1038/s41558-019-0613-7</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx42"><label>Tian et al.(2024)</label><mixed-citation>Tian, H., Pan, N., Thompson, R. L., Canadell, J. G., Suntharalingam, P., Regnier, P., Davidson, E. A., Prather, M., Ciais, P., Muntean, M., Pan, S., Winiwarter, W., Zaehle, S., Zhou, F., Jackson, R. B., Bange, H. W., Berthet, S., Bian, Z., Bianchi, D., Bouwman, A. F., Buitenhuis, E. T., Dutton, G., Hu, M., Ito, A., Jain, A. K., Jeltsch-Thömmes, A., Joos, F., Kou-Giesbrecht, S., Krummel, P. B., Lan, X., Landolfi, A., Lauerwald, R., Li, Y., Lu, C., Maavara, T., Manizza, M., Millet, D. B., Mühle, J., Patra, P. K., Peters, G. P., Qin, X., Raymond, P., Resplandy, L., Rosentreter, J. A., Shi, H., Sun, Q., Tonina, D., Tubiello, F. N., van der Werf, G. R., Vuichard, N., Wang, J., Wells, K. C., Western, L. M., Wilson, C., Yang, J., Yao, Y., You, Y., and Zhu, Q.: Global nitrous oxide budget (1980–2020), Earth Syst. Sci. Data, 16, 2543–2604, <ext-link xlink:href="https://doi.org/10.5194/essd-16-2543-2024" ext-link-type="DOI">10.5194/essd-16-2543-2024</ext-link>, 2024. </mixed-citation></ref>
      <ref id="bib1.bibx43"><label>UNFCCC(2018)</label><mixed-citation>UNFCCC: Paris Climate Change Conference – November 2015: COP 21 Session, <uri>https://unfccc.int/documents/184656</uri> (last access: 4 September 2025), 2018.</mixed-citation></ref>
      <ref id="bib1.bibx44"><label>Waldmann et al.(2026)</label><mixed-citation>Waldmann, P., Eckl, M., Knez, L., Gottschaldt, K.-D., Fiehn, A., Mallaun, C., Gałkowski, M., Kiemle, C., Hutjes, R., Röckmann, T., Chen, H., and Roiger, A.: Quantifying agricultural N<sub>2</sub>O and CH<sub>4</sub> emissions in the Netherlands using an airborne eddy covariance system, Atmos. Meas. Tech., 19, 185–210, <ext-link xlink:href="https://doi.org/10.5194/amt-19-185-2026" ext-link-type="DOI">10.5194/amt-19-185-2026</ext-link>, 2026.</mixed-citation></ref>
      <ref id="bib1.bibx45"><label>Werle et al.(1993)</label><mixed-citation>Werle, P., Mcke, R., and Slemr, F.: The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS), Appl. Phys. B, 57, 131–139, <ext-link xlink:href="https://doi.org/10.1007/BF00425997" ext-link-type="DOI">10.1007/BF00425997</ext-link>, 1993.</mixed-citation></ref>
      <ref id="bib1.bibx46"><label>Xiang et al.(2013)</label><mixed-citation>Xiang, B., Miller, S. M., Kort, E. A., Santoni, G. W., Daube, B. C., Commane, R., Angevine, W. M., Ryerson, T. B., Trainer, M. K., Andrews, A. E., Nehrkorn, T., Tian, H., and Wofsy, S. C.: Nitrous oxide (N2O) emissions from California based on 2010 CalNex airborne measurements, J. Geophys. Res.-Atmos., 118, 2809–2820, <ext-link xlink:href="https://doi.org/10.1002/jgrd.50189" ext-link-type="DOI">10.1002/jgrd.50189</ext-link>, 2013.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Airborne performance assessment of the DLR MIRO MGA<sup>3</sup> quantum cascade laser spectrometer for fast N<sub>2</sub>O measurements</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Behera et al.(2013)</label><mixed-citation>
      
Behera, S. N., Sharma, M., Aneja, V. P., and Balasubramanian, R.: Ammonia in the atmosphere: a review on emission sources, atmospheric chemistry and deposition on terrestrial bodies, Environmental Science and Pollution Research International, 20, 8092–8131, <a href="https://doi.org/10.1007/s11356-013-2051-9" target="_blank">https://doi.org/10.1007/s11356-013-2051-9</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Capasso(2010)</label><mixed-citation>
      
Capasso, F.: High-performance midinfrared quantum cascade lasers, Opt. Eng., 49, 111102, <a href="https://doi.org/10.1117/1.3505844" target="_blank">https://doi.org/10.1117/1.3505844</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>CCAC(2024)</label><mixed-citation>
      
CCAC: Global Nitrous Oxide Assessment – Supplementary Information,   Global Nitrous Oxide Assessment report, <a href="https://www.ccacoalition.org/resources/global-nitrous-oxide-assessment" target="_blank"/> (last access: 8 September 2025), 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Chadwick et al.(2014)</label><mixed-citation>
      
Chadwick, D. R., Cardenas, L., Misselbrook, T. H., Smith, K. A., Rees, R. M., Watson, C. J., McGeough, K. L., Williams, J. R., Cloy, J. M., Thorman, R. E., and Dhanoa, M. S.: Optimizing chamber methods for measuring nitrous oxide emissions from plot–based agricultural experiments, Eur. J. Soil Sci., 65, 295–307, <a href="https://doi.org/10.1111/ejss.12117" target="_blank">https://doi.org/10.1111/ejss.12117</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Chen et al.(2010)</label><mixed-citation>
      
Chen, H., Winderlich, J., Gerbig, C., Hoefer, A., Rella, C. W., Crosson, E. R., Van Pelt, A. D., Steinbach, J., Kolle, O., Beck, V., Daube, B. C., Gottlieb, E. W., Chow, V. Y., Santoni, G. W., and Wofsy, S. C.: High-accuracy continuous airborne measurements of greenhouse gases (CO<sub>2</sub> and CH<sub>4</sub>) using the cavity ring-down spectroscopy (CRDS) technique, Atmos. Meas. Tech., 3, 375–386, <a href="https://doi.org/10.5194/amt-3-375-2010" target="_blank">https://doi.org/10.5194/amt-3-375-2010</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Crawford et al.(2025)</label><mixed-citation>
      
Crawford, J., Lefer, B., Zavaleta, J. R., Adachi, K., Apel, E., Bennett, J. R., Blake, D., Caulton, D., Dibb, J., Digangi, J. P., Diskin, G. S., Franchin, A., Gatebe, C. K., Hall, S., Huey, G., Jimenez, J.-L., Jordan, C., Kim, S., Lee, G., Lee, H., Lee, T., Lim, S., Miech, J., Min, K.-E., Moore, R., Roiger, A., Silverman, M., St. Clair, J., Wennberg, P., Wisthaler, A., Wolfe, G., Yum, S. S., and Zondlo: Airborne and Satellite Investigation of Asian Air Quality Campaign Data, NASA Langley Atmospheric Science Data Center Distributed Active Archive Center [data set], <a href="https://doi.org/10.5067/SUBORBITAL/ASIA-AQ/DATA001" target="_blank">https://doi.org/10.5067/SUBORBITAL/ASIA-AQ/DATA001</a>, 2025.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Dacic et al.(2024)</label><mixed-citation>
      
Dacic, N., Plant, G., and Kort, E. A.: Airborne Measurements Reveal High Spatiotemporal Variation and the Heavy–Tail Characteristic of Nitrous Oxide Emissions in Iowa, J. Geophys. Res.-Atmos., 129, <a href="https://doi.org/10.1029/2024JD041403" target="_blank">https://doi.org/10.1029/2024JD041403</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Davidson and Kanter(2014)</label><mixed-citation>
      
Davidson, E. A. and Kanter, D.: Inventories and scenarios of nitrous oxide emissions, Environ. Res. Lett., 9, 105012, <a href="https://doi.org/10.1088/1748-9326/9/10/105012" target="_blank">https://doi.org/10.1088/1748-9326/9/10/105012</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Del Grosso et al.(2022)</label><mixed-citation>
      
Del Grosso, S. J., Ogle, S. M., Nevison, C., Gurung, R., Parton, W. J., Wagner-Riddle, C., Smith, W., Winiwarter, W., Grant, B., Tenuta, M., Marx, E., Spencer, S., and Williams, S.: A gap in nitrous oxide emission reporting complicates long-term climate mitigation, P. Natl. Acad. Sci. USA, 119, e2200354119, <a href="https://doi.org/10.1073/pnas.2200354119" target="_blank">https://doi.org/10.1073/pnas.2200354119</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Diskin et al.(2002)</label><mixed-citation>
      
Diskin, G. S., Podolske, J. R., Sachse, G. W., and Slate, T. A.: Open-path airborne tunable diode laser hygrometer, in: Diode Lasers and Applications in Atmospheric Sensing, edited by: Fried, A., SPIE Proceedings, p. 196, SPIE,
<a href="https://doi.org/10.1117/12.453736" target="_blank">https://doi.org/10.1117/12.453736</a>, 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Eckl et al.(2021)</label><mixed-citation>
      
Eckl, M., Roiger, A., Kostinek, J., Fiehn, A., Huntrieser, H., Knote, C., Barkley, Z. R., Ogle, S. M., Baier, B. C., Sweeney, C., and Davis, K. J.: Quantifying Nitrous Oxide Emissions in the U.S. Midwest: A Top–Down Study Using High Resolution Airborne In–Situ Observations, Geophys. Res. Lett., 48, <a href="https://doi.org/10.1029/2020GL091266" target="_blank">https://doi.org/10.1029/2020GL091266</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Gordon et al.(2017)</label><mixed-citation>
      
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath,
P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., Drouin, B. J.,
Flaud, J.-M., Gamache, R. R., Hodges, J. T., Jacquemart, D., Perevalov,
V. I., Perrin, A., Shine, K. P., Smith, M.-A., Tennyson, J., Toon, G. C.,
Tran, H., Tyuterev, V. G., Barbe, A., Császár, A. G., Devi, V. M.,
Furtenbacher, T., Harrison, J. J., Hartmann, J.-M., Jolly, A., Johnson,
T. J., Karman, T., Kleiner, I., Kyuberis, A. A., Loos, J., Lyulin, O. M.,
Massie, S. T., Mikhailenko, S. N., Moazzen-Ahmadi, N., Müller, H.,
Naumenko, O. V., Nikitin, A. V., Polyansky, O. L., Rey, M., Rotger, M.,
Sharpe, S. W., Sung, K., Starikova, E., Tashkun, S. A., Auwera, J. V.,
Wagner, G., Wilzewski, J., Wcisło, P., Yu, S., and Zak, E. J.: The
HITRAN2016 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 203, 3–69, <a href="https://doi.org/10.1016/j.jqsrt.2017.06.038" target="_blank">https://doi.org/10.1016/j.jqsrt.2017.06.038</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Gordon et al.(2022)</label><mixed-citation>
      
Gordon, I. E., Rothman, L. S., Hargreaves, R. J., Hashemi, R., Karlovets, E. V., Skinner, F. M., Conway, E. K., Hill, C., Kochanov, R. V., Tan, Y., Wcisło, P., Finenko, A. A., Nelson, K., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., Coustenis, A., Drouin, B. J., Flaud, J.-M., Gamache, R. R., Hodges, J. T., Jacquemart, D., Mlawer, E. J., Nikitin, A. V., Perevalov, V. I., Rotger, M., Tennyson, J., Toon, G. C., Tran, H., Tyuterev, V. G., Adkins, E. M., Baker, A., Barbe, A., Canè, E., Császár, A. G., Dudaryonok, A., Egorov, O., Fleisher, A. J., Fleurbaey, H., Foltynowicz, A., Furtenbacher, T., Harrison, J. J., Hartmann, J.-M., Horneman, V.-M., Huang, X., Karman, T., Karns, J., Kassi, S., Kleiner, I., Kofman, V., Kwabia-Tchana, F., Lavrentieva, N. N., Lee, T. J., Long, D. A., Lukashevskaya, A. A., Lyulin, O. M., Makhnev, V., Matt, W., Massie, S. T., Melosso, M., Mikhailenko, S. N., Mondelain, D., Müller, H., Naumenko, O. V., Perrin, A., Polyansky, O. L., Raddaoui, E., Raston, P. L., Reed, Z. D., Rey, M., Richard, C., Tóbiás, R., Sadiek, I., Schwenke, D. W., Starikova, E., Sung, K., Tamassia, F., Tashkun, S. A., Vander Auwera, J., Vasilenko, I. A., Vigasin, A. A., Villanueva, G. L., Vispoel, B., Wagner, G., Yachmenev, A., and Yurchenko, S. N.: The HITRAN2020 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 277, 107949, <a href="https://doi.org/10.1016/j.jqsrt.2021.107949" target="_blank">https://doi.org/10.1016/j.jqsrt.2021.107949</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Gvakharia et al.(2018)</label><mixed-citation>
      
Gvakharia, A., Kort, E. A., Smith, M. L., and Conley, S.: Testing and evaluation of a new airborne system for continuous N<sub>2</sub>O, CO<sub>2</sub>, CO, and H<sub>2</sub>O measurements: the Frequent Calibration High-performance Airborne Observation System (FCHAOS), Atmos. Meas. Tech., 11, 6059–6074, <a href="https://doi.org/10.5194/amt-11-6059-2018" target="_blank">https://doi.org/10.5194/amt-11-6059-2018</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Gvakharia et al.(2020)</label><mixed-citation>
      
Gvakharia, A., Kort, E. A., Smith, M. L., and Conley, S.: Evaluating Cropland N2O Emissions and Fertilizer Plant Greenhouse Gas Emissions With Airborne Observations, J. Geophys. Res.-Atmos., 125, <a href="https://doi.org/10.1029/2020JD032815" target="_blank">https://doi.org/10.1029/2020JD032815</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Hundt et al.(2018)</label><mixed-citation>
      
Hundt, P. M., Tuzson, B., Aseev, O., Liu, C., Scheidegger, P., Looser, H., Kapsalidis, F., Shahmohammadi, M., Faist, J., and Emmenegger, L.: Multi-species trace gas sensing with dual-wavelength QCLs, Appl. Phys. B, 124, <a href="https://doi.org/10.1007/s00340-018-6977-y" target="_blank">https://doi.org/10.1007/s00340-018-6977-y</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Kanter et al.(2020)</label><mixed-citation>
      
Kanter, D. R., Ogle, S. M., and Winiwarter, W.: Building on Paris: integrating nitrous oxide mitigation into future climate policy, Current Opinion in Environmental Sustainability, 47, 7–12, <a href="https://doi.org/10.1016/j.cosust.2020.04.005" target="_blank">https://doi.org/10.1016/j.cosust.2020.04.005</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Kaufmann et al.(2016)</label><mixed-citation>
      
Kaufmann, S., Voigt, C., Jurkat, T., Thornberry, T., Fahey, D. W., Gao, R.-S., Schlage, R., Schäuble, D., and Zöger, M.: The airborne mass spectrometer AIMS – Part 1: AIMS-H<sub>2</sub>O for UTLS water vapor measurements, Atmos. Meas. Tech., 9, 939–953, <a href="https://doi.org/10.5194/amt-9-939-2016" target="_blank">https://doi.org/10.5194/amt-9-939-2016</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Kiemle et al.(2024)</label><mixed-citation>
      
Kiemle, C., Fix, A., Fruck, C., Ehret, G., and Wirth, M.: Design study for an airborne N<sub>2</sub>O lidar, Atmos. Meas. Tech., 17, 6569–6578, <a href="https://doi.org/10.5194/amt-17-6569-2024" target="_blank">https://doi.org/10.5194/amt-17-6569-2024</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Kostinek et al.(2019)</label><mixed-citation>
      
Kostinek, J., Roiger, A., Davis, K. J., Sweeney, C., DiGangi, J. P., Choi, Y., Baier, B., Hase, F., Groß, J., Eckl, M., Klausner, T., and Butz, A.: Adaptation and performance assessment of a quantum and interband cascade laser spectrometer for simultaneous airborne in situ observation of CH<sub>4</sub>, C<sub>2</sub>H<sub>6</sub>, CO<sub>2</sub>, CO and N<sub>2</sub>O, Atmos. Meas. Tech., 12, 1767–1783, <a href="https://doi.org/10.5194/amt-12-1767-2019" target="_blank">https://doi.org/10.5194/amt-12-1767-2019</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Lebegue et al.(2016)</label><mixed-citation>
      
Lebegue, B., Schmidt, M., Ramonet, M., Wastine, B., Yver Kwok, C., Laurent, O., Belviso, S., Guemri, A., Philippon, C., Smith, J., and Conil, S.: Comparison of nitrous oxide (N<sub>2</sub>O) analyzers for high-precision measurements of atmospheric mole fractions, Atmos. Meas. Tech., 9, 1221–1238, <a href="https://doi.org/10.5194/amt-9-1221-2016" target="_blank">https://doi.org/10.5194/amt-9-1221-2016</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Li et al.(2013)</label><mixed-citation>
      
Li, J. S., Chen, W., and Fischer, H.: Quantum Cascade Laser Spectrometry Techniques: A New Trend in Atmospheric Chemistry, Appl. Spectrosc. Rev., 48, 523–559, <a href="https://doi.org/10.1080/05704928.2012.757232" target="_blank">https://doi.org/10.1080/05704928.2012.757232</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Lopez et al.(2012)</label><mixed-citation>
      
Lopez, M., Schmidt, M., Yver, C., Messager, C., Worthy, D., Kazan, V., Ramonet, M., Bousquet, P., and Ciais, P.: Seasonal variation of N2O emissions in France inferred from atmospheric N2O and 222Rn measurements, J. Geophys. Res.-Atmos., 117, <a href="https://doi.org/10.1029/2012JD017703" target="_blank">https://doi.org/10.1029/2012JD017703</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>MacFarling Meure et al.(2006)</label><mixed-citation>
      
MacFarling Meure, C., Etheridge, D., Trudinger, C., Steele, P., Langenfelds, R., van Ommen, T., Smith, A., and Elkins, J.: Law Dome CO2, CH4 and N2O ice core records extended to 2000 years BP, Geophys. Res. Lett.,
33, <a href="https://doi.org/10.1029/2006GL026152" target="_blank">https://doi.org/10.1029/2006GL026152</a>, 2006.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Myhre et al.(2013)</label><mixed-citation>
      
Myhre, G., Shindell, D., Bréon, F.-M., Collins, W., Fuglestvedt, J., Huang, J., Koch, D., Lamarque, J.-F., Lee, D., Mendoza, B., Nakajima, T., Robock, A., Stephens, G., Takemura, T., and Zhang, H.: Anthropogenic and Natural Radiative Forcing, in: Climate Change 2013: The Physical Science Basis. Contribution of Working Group I to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change, edited by: Stocker, T. F., Qin, D., Plattner, G.-K., Tignor, M., Allen, S. K., Boschung, J., Nauels, A., Xia, Y., Bex, V., and Midgley, P. M., Cambridge University Press, Cambridge, United Kingdom and New York, NY, USA, 659–740,
<a href="https://doi.org/10.1017/CBO9781107415324.018" target="_blank">https://doi.org/10.1017/CBO9781107415324.018</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Pattey et al.(2007)</label><mixed-citation>
      
Pattey, E., Edwards, G. C., Desjardins, R. L., Pennock, D. J., Smith, W., Grant, B., and MacPherson, J. I.: Tools for quantifying N2O emissions from agroecosystems, Agr. Forest Meteorol., 142, 103–119,
<a href="https://doi.org/10.1016/j.agrformet.2006.05.013" target="_blank">https://doi.org/10.1016/j.agrformet.2006.05.013</a>, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Pitt et al.(2016)</label><mixed-citation>
      
Pitt, J. R., Le Breton, M., Allen, G., Percival, C. J., Gallagher, M. W., Bauguitte, S. J.-B., O'Shea, S. J., Muller, J. B. A., Zahniser, M. S., Pyle, J., and Palmer, P. I.: The development and evaluation of airborne in situ N2O and CH4 sampling using a quantum cascade laser absorption spectrometer (QCLAS), Atmos. Meas. Tech., 9, 63–77, <a href="https://doi.org/10.5194/amt-9-63-2016" target="_blank">https://doi.org/10.5194/amt-9-63-2016</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Prather and Wilson(2026)</label><mixed-citation>
      
Prather, M. J. and Wilson, C. P.: Projecting nitrous oxide over the 21st century, uncertainty related to stratospheric loss, P. Natl. Acad. Sci. USA, 123, e2524123123, <a href="https://doi.org/10.1073/pnas.2524123123" target="_blank">https://doi.org/10.1073/pnas.2524123123</a>, 2026.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Prather et al.(2015)</label><mixed-citation>
      
Prather, M. J., Hsu, J., DeLuca, N. M., Jackman, C. H., Oman, L. D., Douglass, A. R., Fleming, E. L., Strahan, S. E., Steenrod, S. D., Søvde, O. A., Isaksen, I. S. A., Froidevaux, L., and Funke, B.: Measuring and modeling the lifetime of nitrous oxide including its variability, J. Geophys. Res.-Atmos., 120, 5693–5705, <a href="https://doi.org/10.1002/2015JD023267" target="_blank">https://doi.org/10.1002/2015JD023267</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Prather et al.(2023)</label><mixed-citation>
      
Prather, M. J., Froidevaux, L., and Livesey, N. J.: Observed changes in stratospheric circulation: decreasing lifetime of N<sub>2</sub>O, 2005–2021, Atmos. Chem. Phys., 23, 843–849, <a href="https://doi.org/10.5194/acp-23-843-2023" target="_blank">https://doi.org/10.5194/acp-23-843-2023</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Rapson and Dacres(2014)</label><mixed-citation>
      
Rapson, T. D. and Dacres, H.: Analytical techniques for measuring nitrous oxide, TrAC-Trend. Anal. Chem., 54, 65–74, <a href="https://doi.org/10.1016/j.trac.2013.11.004" target="_blank">https://doi.org/10.1016/j.trac.2013.11.004</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>Ravishankara et al.(2009)</label><mixed-citation>
      
Ravishankara, A. R., Daniel, J. S., and Portmann, R. W.: Nitrous oxide (N2O): the dominant ozone-depleting substance emitted in the 21st century, Science, 326, 123–125, <a href="https://doi.org/10.1126/science.1176985" target="_blank">https://doi.org/10.1126/science.1176985</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Reay et al.(2012)</label><mixed-citation>
      
Reay, D. S., Davidson, E. A., Smith, K. A., Smith, P., Melillo, J. M., Dentener, F., and Crutzen, P. J.: Global agriculture and nitrous oxide emissions, Nature Climate Change, 2, 410–416, <a href="https://doi.org/10.1038/nclimate1458" target="_blank">https://doi.org/10.1038/nclimate1458</a>,
2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Rella et al.(2013)</label><mixed-citation>
      
Rella, C. W., Chen, H., Andrews, A. E., Filges, A., Gerbig, C., Hatakka, J., Karion, A., Miles, N. L., Richardson, S. J., Steinbacher, M., Sweeney, C., Wastine, B., and Zellweger, C.: High accuracy measurements of dry mole fractions of carbon dioxide and methane in humid air, Atmos. Meas. Tech., 6, 837–860, <a href="https://doi.org/10.5194/amt-6-837-2013" target="_blank">https://doi.org/10.5194/amt-6-837-2013</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Rogelj and Lamboll(2024)</label><mixed-citation>
      
Rogelj, J. and Lamboll, R. D.: Substantial reductions in non-CO2 greenhouse gas emissions reductions implied by IPCC estimates of the remaining carbon budget, Commun. Earth Environ., 5, <a href="https://doi.org/10.1038/s43247-023-01168-8" target="_blank">https://doi.org/10.1038/s43247-023-01168-8</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>Saboya et al.(2024)</label><mixed-citation>
      
Saboya, E., Manning, A. J., Levy, P., Stanley, K. M., Pitt, J., Young, D., Say, D., Grant, A., Arnold, T., Rennick, C., Tomlinson, S. J., Carnell, E. J., Artioli, Y., Stavert, A., Spain, T. G., O'Doherty, S., Rigby, M., and Ganesan, A. L.: Combining Top–Down and Bottom–Up Approaches to Evaluate Recent Trends and Seasonal Patterns in UK N2O Emissions, J. Geophys. Res.-Atmos., 129, <a href="https://doi.org/10.1029/2024JD040785" target="_blank">https://doi.org/10.1029/2024JD040785</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>Sachse et al.(1987)</label><mixed-citation>
      
Sachse, G. W., Hill, G. F., Wade, L. O., and Perry, M. G.: Fast–response, high–precision carbon monoxide sensor using a tunable diode laser absorption technique, J. Geophys. Res.-Atmos., 92, 2071–2081, <a href="https://doi.org/10.1029/JD092iD02p02071" target="_blank">https://doi.org/10.1029/JD092iD02p02071</a>, 1987.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>Schiller et al.(2008)</label><mixed-citation>
      
Schiller, C. L., Bozem, H., Gurk, C., Parchatka, U., Königstedt, R., Harris, G. W., Lelieveld, J., and Fischer, H.: Applications of quantum cascade lasers for sensitive trace gas measurements of CO, CH4, N2O and HCHO, Appl. Phys. B, 92, 419–430, <a href="https://doi.org/10.1007/s00340-008-3125-0" target="_blank">https://doi.org/10.1007/s00340-008-3125-0</a>, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>Scott et al.(1990)</label><mixed-citation>
      
Scott, S. G., Bui, T. P., Chan, K. R., and Bowen, S. W.: The Meteorological Measurement System on the NASA ER-2 Aircraft, J. Atmos. Ocean. Tech., 7, 525–540, <a href="https://doi.org/10.1175/1520-0426(1990)007&lt;0525:TMMSOT&gt;2.0.CO;2" target="_blank">https://doi.org/10.1175/1520-0426(1990)007&lt;0525:TMMSOT&gt;2.0.CO;2</a>, 1990.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>Smith(2017)</label><mixed-citation>
      
Smith, K. A.: Changing views of nitrous oxide emissions from agricultural soil: key controlling processes and assessment at different spatial scales, Eur. J. Soil Sci., 68, 137–155, <a href="https://doi.org/10.1111/ejss.12409" target="_blank">https://doi.org/10.1111/ejss.12409</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>Thompson et al.(2019)</label><mixed-citation>
      
Thompson, R. L., Lassaletta, L., Patra, P. K., Wilson, C., Wells, K. C., Gressent, A., Koffi, E. N., Chipperfield, M. P., Winiwarter, W., Davidson, E. A., Tian, H., and Canadell, J. G.: Acceleration of global N2O emissions seen from two decades of atmospheric inversion, Nature Climate Change, 9, 993–998, <a href="https://doi.org/10.1038/s41558-019-0613-7" target="_blank">https://doi.org/10.1038/s41558-019-0613-7</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>Tian et al.(2024)</label><mixed-citation>
      
Tian, H., Pan, N., Thompson, R. L., Canadell, J. G., Suntharalingam, P., Regnier, P., Davidson, E. A., Prather, M., Ciais, P., Muntean, M., Pan, S., Winiwarter, W., Zaehle, S., Zhou, F., Jackson, R. B., Bange, H. W., Berthet, S., Bian, Z., Bianchi, D., Bouwman, A. F., Buitenhuis, E. T., Dutton, G., Hu, M., Ito, A., Jain, A. K., Jeltsch-Thömmes, A., Joos, F., Kou-Giesbrecht, S., Krummel, P. B., Lan, X., Landolfi, A., Lauerwald, R., Li, Y., Lu, C., Maavara, T., Manizza, M., Millet, D. B., Mühle, J., Patra, P. K., Peters, G. P., Qin, X., Raymond, P., Resplandy, L., Rosentreter, J. A., Shi, H., Sun, Q., Tonina, D., Tubiello, F. N., van der Werf, G. R., Vuichard, N., Wang, J., Wells, K. C., Western, L. M., Wilson, C., Yang, J., Yao, Y., You, Y., and Zhu, Q.: Global nitrous oxide budget (1980–2020), Earth Syst. Sci. Data, 16, 2543–2604, <a href="https://doi.org/10.5194/essd-16-2543-2024" target="_blank">https://doi.org/10.5194/essd-16-2543-2024</a>, 2024.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>UNFCCC(2018)</label><mixed-citation>
      
UNFCCC: Paris Climate Change Conference – November 2015: COP 21 Session, <a href="https://unfccc.int/documents/184656" target="_blank"/> (last access: 4 September 2025), 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>Waldmann et al.(2026)</label><mixed-citation>
      
Waldmann, P., Eckl, M., Knez, L., Gottschaldt, K.-D., Fiehn, A., Mallaun, C., Gałkowski, M., Kiemle, C., Hutjes, R., Röckmann, T., Chen, H., and Roiger, A.: Quantifying agricultural N<sub>2</sub>O and CH<sub>4</sub> emissions in the Netherlands using an airborne eddy covariance system, Atmos. Meas. Tech., 19, 185–210, <a href="https://doi.org/10.5194/amt-19-185-2026" target="_blank">https://doi.org/10.5194/amt-19-185-2026</a>, 2026.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>Werle et al.(1993)</label><mixed-citation>
      
Werle, P., Mcke, R., and Slemr, F.: The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS), Appl. Phys. B, 57, 131–139,
<a href="https://doi.org/10.1007/BF00425997" target="_blank">https://doi.org/10.1007/BF00425997</a>, 1993.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>Xiang et al.(2013)</label><mixed-citation>
      
Xiang, B., Miller, S. M., Kort, E. A., Santoni, G. W., Daube, B. C., Commane, R., Angevine, W. M., Ryerson, T. B., Trainer, M. K., Andrews, A. E., Nehrkorn, T., Tian, H., and Wofsy, S. C.: Nitrous oxide (N2O) emissions from California based on 2010 CalNex airborne measurements, J. Geophys. Res.-Atmos., 118, 2809–2820, <a href="https://doi.org/10.1002/jgrd.50189" target="_blank">https://doi.org/10.1002/jgrd.50189</a>, 2013.

    </mixed-citation></ref-html>--></article>
