Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

IF value: 3.668
IF3.668
IF 5-year value: 3.707
IF 5-year
3.707
CiteScore value: 6.3
CiteScore
6.3
SNIP value: 1.383
SNIP1.383
IPP value: 3.75
IPP3.75
SJR value: 1.525
SJR1.525
Scimago H <br class='widget-line-break'>index value: 77
Scimago H
index
77
h5-index value: 49
h5-index49
Volume 7, issue 12
Atmos. Meas. Tech., 7, 4167–4184, 2014
https://doi.org/10.5194/amt-7-4167-2014
© Author(s) 2014. This work is distributed under
the Creative Commons Attribution 3.0 License.

Special issue: Atmospheric limb imaging with GLORIA

Atmos. Meas. Tech., 7, 4167–4184, 2014
https://doi.org/10.5194/amt-7-4167-2014
© Author(s) 2014. This work is distributed under
the Creative Commons Attribution 3.0 License.

Research article 05 Dec 2014

Research article | 05 Dec 2014

Level 0 to 1 processing of the imaging Fourier transform spectrometer GLORIA: generation of radiometrically and spectrally calibrated spectra

A. Kleinert1, F. Friedl-Vallon1, T. Guggenmoser2,*, M. Höpfner1, T. Neubert3, R. Ribalda3,**, M. K. Sha1, J. Ungermann2, J. Blank2, A. Ebersoldt4, E. Kretschmer1, T. Latzko1, H. Oelhaf1, F. Olschewski5, and P. Preusse2 A. Kleinert et al.
  • 1Institut für Meteorologie und Klimaforschung, Karlsruher Institut für Technologie, Karlsruhe, Germany
  • 2Institut für Energie und Klimaforschung – Stratosphäre, Forschungszentrum Jülich, Jülich, Germany
  • 3Zentralinstitut für Engineering, Elektronik und Analytik-Systeme der Elektronik (ZEA-2), Forschungszentrum Jülich Jülich, Germany
  • 4Institut für Prozessdatenverarbeitung und Elektronik, Karlsruher Institut für Technologie, Karlsruhe, Germany
  • 5Fachbereich C – Atmosphärenphysik, Bergische Universität Wuppertal, Wuppertal, Germany
  • *now at: European Space Agency, Noordwijk, the Netherlands
  • **now at: Escuela Politécnica Superior, Universidad Autónoma de Madrid, Madrid, Spain

Abstract. The Gimballed Limb Observer for Radiance Imaging of the Atmosphere (GLORIA) is an imaging Fourier transform spectrometer that is capable of operating on various high-altitude research aircraft. It measures the atmospheric emission in the thermal infrared spectral region in limb and nadir geometry. GLORIA consists of a classical Michelson interferometer combined with an infrared camera. The infrared detector has a usable area of 128 × 128 pixels, measuring up to 16 384 interferograms simultaneously.

Imaging Fourier transform spectrometers impose a number of challenges with respect to instrument calibration and algorithm development. The optical setup with extremely high optical throughput requires the development of new methods and algorithms for spectral and radiometric calibration. Due to the vast amount of data there is a high demand for scientifically intelligent optimisation of the data processing.

This paper outlines the characterisation and processing steps required for the generation of radiometrically and spectrally calibrated spectra. Methods for performance optimisation of the processing algorithm are presented. The performance of the data processing and the quality of the calibrated spectra are demonstrated for measurements collected during the first deployments of GLORIA on aircraft.