<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" dtd-version="3.0">
  <front>
    <journal-meta>
<journal-id journal-id-type="publisher">AMT</journal-id>
<journal-title-group>
<journal-title>Atmospheric Measurement Techniques</journal-title>
<abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">1867-8548</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>

    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-9-2195-2016</article-id><title-group><article-title>Detection and quantification of gas-phase oxidized <?xmltex \hack{\break}?>mercury compounds by
GC/MS</article-title>
      </title-group><?xmltex \runningtitle{Detection and quantification of gas-phase oxidized mercury compounds by
GC/MS}?><?xmltex \runningauthor{C. P. Jones et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Jones</surname><given-names>Colleen P.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Lyman</surname><given-names>Seth N.</given-names></name>
          <email>seth.lyman@usu.edu</email>
        <ext-link>https://orcid.org/0000-0001-8493-9522</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Jaffe</surname><given-names>Daniel A.</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Allen</surname><given-names>Tanner</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>O'Neil</surname><given-names>Trevor L.</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Bingham Research Center, Utah State University, Vernal, UT 84078, USA</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>University of Washington-Bothell, Bothell, WA 98011, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Seth N. Lyman (seth.lyman@usu.edu)</corresp></author-notes><pub-date><day>18</day><month>May</month><year>2016</year></pub-date>
      
      <volume>9</volume>
      <issue>5</issue>
      <fpage>2195</fpage><lpage>2205</lpage>
      <history>
        <date date-type="received"><day>28</day><month>January</month><year>2016</year></date>
           <date date-type="rev-request"><day>29</day><month>February</month><year>2016</year></date>
           <date date-type="rev-recd"><day>26</day><month>April</month><year>2016</year></date>
           <date date-type="accepted"><day>27</day><month>April</month><year>2016</year></date>
      </history>
      <permissions>
<license license-type="open-access">
<license-p>This work is licensed under a Creative Commons Attribution 3.0 Unported License. To view a copy of this license, visit <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/3.0/">http://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions><self-uri xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016.html">This article is available from https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016.html</self-uri>
<self-uri xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016.pdf</self-uri>


      <abstract>
    <p>Most mercury pollution is emitted to the atmosphere, and the
location and bioavailability of deposited mercury largely depends on poorly
understood atmospheric chemical reactions that convert elemental mercury
into oxidized mercury compounds. Current measurement methods do not speciate
oxidized mercury, leading to uncertainty about which mercury compounds exist
in the atmosphere and how oxidized mercury is formed. We have developed a
gas chromatography/mass spectrometry (GC-MS)-based system for identification and
quantification of atmospheric oxidized mercury compounds. The system
consists of an ambient air collection device, a thermal desorption module, a
cryofocusing system, a gas chromatograph, and an ultra-sensitive mass
spectrometer. It was able to separate and identify mercury halides with
detection limits low enough for ambient air collection (90 pg), but an
improved ambient air collection device is needed. The GC/MS system was unable to quantify HgO or Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and data collected cast doubt
upon the existence of HgO in the gas phase.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p>Mercury (Hg) emitted in the gas phase can remain in the Earth's atmosphere
for many months and be transported around the globe (Lindberg et al.,
2007). Atmospheric Hg pollution is a global problem, and regulation of Hg
emissions exist at the state, national, and international levels (Selin,
2009). Hg pollution arises from a variety of natural and anthropogenic point
and nonpoint sources (Gustin et al., 2008; Seigneur et al., 2004). Hg can
exist in the atmosphere as elemental Hg (Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, or as various oxidized
Hg compounds (Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (Lyman et al., 2010a). Most mercury
is emitted to the atmosphere as Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> (Pacyna et al., 2006),
but it can be oxidized to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> in the atmosphere, and Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> can be
reduced to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> (Hedgecock and Pirrone, 2004). Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> can be
found in both the particulate-bound (Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>p</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and gaseous forms
(Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>g</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (Sprovieri et al., 2010) and is water-soluble
and semi-volatile (Gustin et al., 2008; Lindberg et al., 2007). As a
result, aerosols and clouds readily absorb Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>g</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula>, and it is also
readily dry deposited (Holmes, 2012; Lyman et al., 2007). Lyman
and Jaffe (2012) and others (Gratz et al., 2015; Slemr et al., 2009;
Talbot et al., 2007) report that the upper troposphere and lower
stratosphere are depleted in Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> and enriched in Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula>, and
oxidation of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> has also been shown to occur in the
marine boundary layer (Wang et al., 2014) and the Arctic during
springtime (Steffen et al., 2008). The location and timing of
Hg deposition to ecosystems depends on atmospheric chemistry and the form of
Hg in the air (Gustin et al., 2013b; Holmes et al., 2010; Lin et al.,
2006; Lyman and Gustin, 2008; Lyman et al., 2010a).</p>
      <p>In 1974, Johnson and Braman (1974) suggested that oxidized Hg
might consist of HgO and/or Hg halides, and most current studies still echo
this hypothesis (Ariya et al., 2009; Holmes et al., 2010; Hynes et al.,
2009; Lin et al., 2006). HgO could be produced by the reaction of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> with
ozone (Pal and Ariya, 2004b), OH (Pal and Ariya,
2004a), or NO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> (Sommar et al., 1997). Evidence exists for the
involvement of NO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> in formation of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> (Peleg et al., 2015).
Some have argued that HgO is likely to exist only as Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>p</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula>
(Calvert and Lindberg, 2005; Shepler and Peterson, 2003) and that
oxidation of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> by ozone may produce an HgO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> intermediate which
could decompose to HgO on particles (Calvert and
Lindberg, 2005) or react with water to form Hg(OH)<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> (Tossell, 2006). Seigneur et al. (1994) suggested
that Hg(OH)<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> could be produced from the reaction of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> with
H<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>.</p>
      <p>Reactive halogen species, especially bromine species, have received attention
as potential Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> oxidants since the discovery of Hg depletion events
associated with “bromine explosions” during Arctic spring (Schroeder et
al., 1998; Steffen et al., 2008), and HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and/or HgBrOH have been
hypothesized as products (Holmes et al., 2006). Halogen radicals have also
been implicated as potential Hg oxidants in the marine boundary layer
(Laurier et al., 2003), the Dead Sea (Obrist et al., 2011), and the free troposphere and stratosphere (Holmes et al., 2006).</p>
      <p>Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> emitted from combustion facilities is generally thought to be
HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> (Galbreath and Zygarlicke, 2000; Wilcox and Blowers, 2004).
Some oxidized Hg in the atmosphere may be methylmercury, but less than 3 % of oxidized Hg in rainwater is methylated (Lindberg et al.,
2007), and it is likely that most atmospheric Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> is inorganic.</p>
      <p>Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>, Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>p</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula>, and Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>g</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula> (operationally defined) are
measured routinely at dozens of locations around the world. Current
measurement methods for Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>g</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula> have been shown to be biased low,
however (Gustin et al., 2013a; McClure et al., 2014), and ozone and water
vapor have been implicated as interferences (Huang and Gustin,
2015; Lyman et al., 2010b). These measurements have only been calibrated
rarely, and development and regular deployment of a field-deployable
calibrator has been called for (Gustin et al., 2013b; Jaffe et al.,
2014). Current Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> instrumentation is also not species-specific, so it
does not provide information about the individual compounds that make up
measured Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> (Jaffe et al., 2014). Different species will have
different deposition rates, solubility, and bioavailability (Eagles-Smith
and Ackerman, 2014; Peterson et al., 2015), so determining the chemical
nature of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> is a critical research priority (Gustin et al.,
2013b; Jaffe et al., 2014; Malcolm and Keeler, 2007). Huang et al. (2013b) have
developed a thermal desorption system to provide chemical
information about Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>g</mml:mtext><mml:mtext>II</mml:mtext></mml:msubsup></mml:mrow></mml:math></inline-formula>, but other, complimentary methods are also
needed.</p>
      <p>Unlike the atomic fluorescence method commonly used for measurement of
atmospheric Hg, mass spectrometric methods can be used to identify the
chemical composition of Hg compounds (Deeds et al., 2015). Further, gas
chromatography/mass spectrometry (GC/MS) can allow for separation of
individual Hg compounds and separation of Hg compounds from non-mercury
components of ambient air samples (Babko et al., 2001; Olson et al., 2002). Inductively
coupled plasma mass spectrometry (ICP-MS) is routinely used for measurement of Hg
and Hg isotope ratios, but the method is only useful for elemental analysis
(dos Santos et al., 2009). GC analysis is routinely used for analysis of
organic Hg in various media, and for analysis of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> in water after
alkylation of the inorganic Hg compounds (Cavalheiro et al., 2014).
However, alkylation destroys the native structure of Hg compounds and thus
does not provide information about their original identity.</p>
      <p>Babko et al. (2001) showed that GC/MS could be used to
separate and identify Hg halides. They injected a solution of HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> in
acetone into a GC/MS and found good recovery and consistent peaks. The
detection limits, however, were much higher than would be practical for
ambient air analysis. Olson et al. (2002) used GC/MS to identify Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula>
generated by an MnO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> sorbent in simulated flue gas. They used an
impinger to trap the Hg in acetonitrile, then evaporatively concentrated the
solution before injecting into a GC/MS. They injected HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> in
acetonitrile and observed mass spectra that were clearly indicative of
HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>. They also injected Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and
Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> H<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O and saw a similar peak and mass
spectra to what they observed in the gas that passed through the MnO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
sorbent.</p>
      <p>We have developed a GC/MS-based system to quantify and chemically identify
Hg compounds. We describe this analytical system in detail, provide first
results, and discuss remaining challenges.</p><?xmltex \hack{\vspace{-3mm}}?>
</sec>
<sec id="Ch1.S2">
  <title>Materials and methods</title>
      <p>The GC/MS-based Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> detection system consisted of a sample collector
to concentrate Hg compounds from the ambient atmosphere, a sample desorber
to introduce collected compounds into the gas phase, a cryogenic
preconcentrator (cryotrap) to focus and inject Hg compounds, a gas
chromatograph to separate Hg compounds from each other and from possible
interferents, and an ultra-sensitive mass spectrometer to definitively
determine the chemical speciation of Hg compounds (Fig. 1). It also
incorporated a permeation system, pyrolyzer, and Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> detector to
introduce a consistent, quantifiable amount of various Hg compounds to the
system in the gas phase. All wetted parts of the system were kept at at
least 160 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (except the sample desorber, which was sometimes
cooler), and all wetted parts except the GC columns and VICI GC valve rotors
were composed of deactivated fused silica-coated stainless steel. The VICI
GC valve rotors were composed of Valcon E (a polyaryletherketone/PTFE
composite).</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><caption><p>Diagram of GC/MS system used to identify Hg compounds, and a
pyrolyzer and Tekran 2537 system to quantify the amount of Hg compounds
generated by the permeation oven.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016-f01.png"/>

      </fig>

<?xmltex \hack{\newpage}?>
<sec id="Ch1.S2.SS1">
  <title>Sample collector</title>
      <p>Four collection materials were tested for suitability to concentrate
volatile Hg compounds in air samples. Collection materials tested were nylon
membranes, polydimethylsiloxane (PDMS) sorption tubes, quartz wool-filled
tubes, and deactivate fused silica-coated stainless steel. Nylon membranes
were Cole-Parmer nylon polyamide membranes (47 mm round, 0.2 <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>m thick,
P/N: EW-36229-04). The PDMS sorption tubes were those for a Gerstel Thermal
Desorption Unit (TDU), and were filled with conditioned PDMS foam (P/N:
013758-105-00). Quartz wool-filled tubes were made from 22 cm long <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 1.3 cm diameter
perfluoroalkoxy (PFA) tubing that was washed with
soap and water, soaked for 24 h in a 10 % nitric acid bath, rinsed
with 18.2 M<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> water, then dried in a particle-free
environment. The tubing was then filled with quartz wool that had been baked
at 800 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for 2 h to ensure no contamination. Deactivated
fused silica-coated stainless steel was a 1 cm length of 0.3 cm tubing.</p>
      <p>Selection of the best collection surface was based on presence of
identifiable Hg peaks on the GC/MS with the least amount of signal
interference. Hg was introduced to the sample collectors either from the
permeation oven or by passing outdoor ambient air through the collectors.
Ambient air samples were collected from Peavine Peak (latitude 39.590,
longitude <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>119.929) near Reno, Nevada; at the University of Nevada, Reno
campus in Reno, Nevada (latitude 39.537, longitude <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>119.805); and Grizzly
Ridge (latitude 40.738, longitude <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>109.484) near Vernal, Utah, using quartz
wool-filled tubes and nylon membranes. Quartz wool-filled tube ambient air
samples were collected by pulling air through the tubes at 30 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>
for 3 h. Some of the tubes were at ambient temperature during
collection, while others were kept at 0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. Nylon membranes were
collected by pulling air through the membranes at 1 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for 2
weeks. More information about nylon membrane methods is available from
Huang et al. (2013a). All ambient air samples were collected during
summer months.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <title>Sample desorber</title>
      <p>A thermal desorption module was used to reintroduce collected compounds into
the gas phase. We constructed this module by connecting a lab oven to an
adjustable digital temperature controller. Membrane samples were placed
within a sample desorption chamber inside the oven, while sample collection
tubes were connected directly to the desorption flow path. The desorption
chamber was stainless steel coated with deactivated fused silica. A constant
flow of ultra-high purity (UHP) Helium (He) acted as a carrier gas to pass
volatilized compounds to the cryotrap. The flow of UHP He was controlled at
a rate of 30 mL min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Desorption temperatures in the range of
80–160 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C were used.<?xmltex \hack{\newpage}?></p>
</sec>
<sec id="Ch1.S2.SS3">
  <title>Cryogenic preconcentrator</title>
      <p>The cryogenic preconcentrator (cryotrap) was used to focus desorbed
compounds prior to introduction into the GC. A Scientific Instrument
Services Model 961 GC Cryo-Trap was used with liquid nitrogen as the
cryogen. The cryotrap works by enclosing a portion of the GC column in a
small metal cylinder. A flow of liquid nitrogen is passed through the small
cylinder at a rate determined by a digital temperature controller. Volatile
compounds are retained on the cooled column. After collection, the metal
cylinder rapidly heats up via a nichrome wire heating coil, volatilizing
concentrated compounds and allowing them to pass into the GC/MS. During this
step, the trap temperature is able to increase by 14 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C per
second. Cryotrap cooling temperatures tested ranged from <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>50
to 30 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, and heating temperatures tested ranged from
170 to 240 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. The cryotrap was housed in a lab oven.
Lab oven temperatures tested ranged from 160 to 220 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. A VICI six-port GC valve (Model 4C6WT) was housed within the lab oven and
controlled flow of sample to the cryotrap, and from the cryotrap to the
GC. A heated line with a deactivated fused silica guard column (0.25 mm
internal diameter) was used to connect the cryotrap to the GC.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <title>Gas chromatograph with an ultra-sensitive mass spectrometer</title>
      <p>A Shimadzu GC-2010 Plus gas chromatograph was used to separate Hg compounds
from each other and from possible interferents. Different GC column types
and lengths were used to test optimum conditions for Hg compound separation.
A 30 m low-polarity Restek Rxi-5Sil MS column (5 % diphenyl/95 %
dimethyl polysiloxane), a 60 m ultra-low-polarity Supelco SPB-Octyl
fused silica capillary column (50 % <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>-Octyl/50 % methyl siloxane), and a
30 m non-polar Restek Rxi-1ms column (100 % dimethyl polysiloxane)
were tested. GC oven temperatures tested ranged from 140 to
220 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. After passing through the GC column, the compounds of
interest moved to a Shimadzu QP2010 Ultra mass spectrometer for detection of
unique chemical signatures of Hg compounds in samples. The MS was operated
in high-sensitivity electron impact ionization mode, and included a direct
probe inlet. Small quantities of solid-phase Hg compounds were added
directly to the MS via to the direct probe inlet to determine representative
mass spectra for the compounds.</p>
</sec>
<sec id="Ch1.S2.SS5">
  <title>Permeation system, pyrolyzer, and Hg detector</title>
      <p>Permeation tubes were made to generate four Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> compounds (HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>,
HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>, and HgO; Sigma-Aldrich, purity 99.9 % or
greater). These compounds were packed in permeation tubes constructed of
thin-wall 0.3 cm diameter FEP tubing with solid polytetrafluoroethylene (PTFE)
plugs in both ends. The permeable length of each tube was
approximately 1 mm. Larger permeation tubes (1.3 cm diameter <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 15 cm permeable length) were also tested for Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> and HgO.
Permeation tubes were enclosed within 0.5 cm inner diameter deactivated
fused silica-coated stainless steel tubing. UHP He flowed at 30 mL min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>
through the stainless steel tubing and over the permeation tubes.
The tubes were house in an oven consisting of an insulated metal box heated
to 100 <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 0.1 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. A VICI multiport GC valve (Model CSF6)
selected among four available permeation tubes or passed permeation flow to
vent. The multiport valve was housed within the same lab oven as the
cryotrap.</p>
      <p>A pyrolyzer was used to verify permeation rates of Hg compounds. The
pyrolyzer consisted of a 2.5 cm diameter <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 18 cm length quartz tube
packed with quartz wool. The quartz tube was wrapped with nichrome wire that
was used with a variable voltage controller to control the temperature of
the tube. The pyrolyzer was kept at 800 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C to convert Hg compounds
to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> as they passed from the permeation oven through the quartz tube.
Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> concentrations were measured downstream of the pyrolyzer using a
Tekran 2537 mercury vapor analyzer.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p>Chromatogram of a mixed standard of HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> in
acetone (0.5 <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">mu</mml:mi></mml:math></inline-formula>g <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>L<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for each compound) (top), mass
spectra for HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> (<bold>b</bold>, middle) and HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> (<bold>b</bold>, bottom). Solvent delay
was 2 min.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016-f02.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><caption><p>Picograms of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> and Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> recovered when HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> was
permeated into mercury-free air and passed through a 15 cm section of 0.3 cm
diameter tubing constructed of the materials indicated. Tubing was kept at
110–115 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, except when indicated otherwise. “Siltek” indicates
stainless steel tubing coated with Siltek-brand deactivated fused silica.
Whiskers represent 95 % confidence intervals.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016-f03.png"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS6">
  <title>Hg compound transmission tests</title>
      <p>We permeated HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> into a 1 cm diameter PFA manifold to test the
ability of different materials to transmit Hg compounds (Fig. S1 in the Supplement). The
manifold was heated to 100 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. Air scrubbed of Hg via an activated
carbon cartridge was drawn through the manifold at 10 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. A tee
pulled a 1 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> subset of air from this manifold into a Tekran
2537/1130 speciation system with a KCl-coated denuder, which measured
Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> and Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula>. The tee to the denuder was 100 cm downstream of the
point where HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> was added to the manifold air. One of several 15 cm
long <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 0.3 cm diameter tubes was placed between the manifold and
the Tekran speciation system to test the ability of these tubes to transmit
HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>. These 15 cm tubes were constructed of different materials,
including stainless steel, PFA (as a control, since the entire manifold was
PFA), PEEK, and deactivated fused silica-coated stainless steel. Fittings
used to secure the 15 cm tubes were of the same materials as the tubes. The
15 cm stainless steel, PFA, PEEK, and deactivated fused silica-coated
stainless steel tubes were each tested for 24 h. The Tekran system collected
one measurement every 1.5 h, so approximately 16 samples were obtained
for each experimental condition.
<?xmltex \hack{\vspace{-3mm}}?></p>
</sec>
</sec>
<sec id="Ch1.S3">
  <title>Results and discussion</title>
      <p>We initially identified HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> via the method utilized by
Babko et al. (2001), which was to dissolve the compounds in
acetone and inject the solution into a splitless inlet at 200 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C.
We used a non-polar 100 % PDMS column at 160 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C for separation.
We were able to separate HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> from HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> with this system (Fig. 2).
The relative abundance of Hg isotopes in Fig. 2 is similar to isotopic
abundances reported by IUPAC (de Laeter et al.,
2004), confirming the identification. The detection limit of HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
analyzed by this method, calculated as 3 times the standard deviation of
seven injections near the detection limit, was 9 ng, much too high for
ambient air detection of mercury compounds. Replicate injections showed a
high degree of variability (relative standard deviation of 30 to 45 %).
The manual syringe used for injections became permanently contaminated with
HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> after use, so we expect that much of the observed
variability was due to retention and interactions on the syringe walls, as
well as the walls of the injection port.</p>
      <p>To eliminate the variability created by liquid injections of these very
reactive compounds, we developed the system described in Methods. We tested
a number of different configurations and materials to determine the method
most likely to allow for identification of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> in ambient air.</p>
<sec id="Ch1.S3.SS1">
  <title>System materials and temperatures</title>
      <p>As a first step in the development of the system, we tested the ability of
stainless steel, deactivated fused silica-coated stainless steel (Siltek
brand), PFA, and PEEK tubing to transmit gas-phase HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>. The lowest
Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> recovery (and highest Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> was observed with stainless steel
tubing, followed by PEEK (Fig. 3). Deactivated fused silica-coated stainless
steel performed better than PFA, with more Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> and less Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>
observed. The amount of total Hg recovered was the same whether deactivated
fused silica-coated stainless steel was heated to 135 or
110–115 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>p</mml:mi><mml:mo>=</mml:mo></mml:mrow></mml:math></inline-formula> 0.39; the manifold used for these tests was not
capable of achieving more than 135 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C), but the percentage of
recovered Hg that was Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> increased from 83 to 98 %. It is not
clear why the 15 cm deactivated fused silica-coated stainless steel tube at
135 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C resulted in such an improved Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>:</mml:mo></mml:math></inline-formula> Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> ratio
relative to the 15 cm PFA tubing, since a relatively short length of coated
stainless tubing was used in a manifold that was otherwise constructed
entirely of PFA, and some decomposition of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> would be
expected in the remainder of the manifold even if the 15 cm tube did not
lead to any decomposition. More study of Hg compound decomposition in the
presence of different materials is warranted.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><caption><p>GC/MS results from permeation of HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> with varying GC oven,
valve oven, and line temperatures. Each iteration was performed at least in
duplicate to verify the consistency of results. Peak area and height are for
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 362.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">GC oven</oasis:entry>  
         <oasis:entry colname="col2">Retention</oasis:entry>  
         <oasis:entry colname="col3">Peak</oasis:entry>  
         <oasis:entry colname="col4">Peak</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">temp. (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>  
         <oasis:entry colname="col2">time</oasis:entry>  
         <oasis:entry colname="col3">area</oasis:entry>  
         <oasis:entry colname="col4">height</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">140</oasis:entry>  
         <oasis:entry colname="col2">5.91</oasis:entry>  
         <oasis:entry colname="col3">11 794</oasis:entry>  
         <oasis:entry colname="col4">802</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">160</oasis:entry>  
         <oasis:entry colname="col2">4.52</oasis:entry>  
         <oasis:entry colname="col3">14 676</oasis:entry>  
         <oasis:entry colname="col4">1077</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">180</oasis:entry>  
         <oasis:entry colname="col2">3.87</oasis:entry>  
         <oasis:entry colname="col3">17 037</oasis:entry>  
         <oasis:entry colname="col4">1158</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">200</oasis:entry>  
         <oasis:entry colname="col2">2.66</oasis:entry>  
         <oasis:entry colname="col3">22 892</oasis:entry>  
         <oasis:entry colname="col4">1235</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Valve oven and</oasis:entry>  
         <oasis:entry namest="col2" nameend="col4" align="center">  </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">line temp. (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>  
         <oasis:entry namest="col2" nameend="col4" align="center">  </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">180</oasis:entry>  
         <oasis:entry colname="col2">4.32</oasis:entry>  
         <oasis:entry colname="col3">36 058</oasis:entry>  
         <oasis:entry colname="col4">1989</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">200</oasis:entry>  
         <oasis:entry colname="col2">4.19</oasis:entry>  
         <oasis:entry colname="col3">40 646</oasis:entry>  
         <oasis:entry colname="col4">1998</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p>It appears from Fig. 3 that cooler temperatures and less suitable tubing
materials led to the conversion of HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>, perhaps due to
reactions facilitated by or on the materials themselves. Others have
reported that higher temperatures allow for increased transmission of Hg
halides without significant decomposition to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> (Lyman et
al., 2010b). Wilcox and Blowers (2004) determined a theoretical
temperature-dependent rate constant for the decomposition of HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
(HgCl<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>+</mml:mo></mml:mrow></mml:math></inline-formula> M <inline-formula><mml:math display="inline"><mml:mo>↔</mml:mo></mml:math></inline-formula> HgCl <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> Cl <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> M), and compared those
results to rate constants developed from experimental data (Widmer
et al., 2000). Their theoretical rate equation predicts that HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> will
be stable up to about 850 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, while the rate equation determined
from experimental data predicts HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> stability up to 450 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C
(stable <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> less than half of initial HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> decomposed within 60 s). At
240 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C (the maximum temperature reached by any part of our GC/MS
system), both rate equations predict <inline-formula><mml:math display="inline"><mml:mo>≪</mml:mo></mml:math></inline-formula> 1 % decomposition
within 60 s. In addition, L'Vov (1999) showed minimal decomposition of HgO up
to 450 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C.</p>
      <p>We constructed the plumbing of our GC/MS system using deactivated fused
silica-coated stainless steel where possible. After the system was
constructed, we tested different system temperature settings, including
temperatures of the oven that housed the VICI valves and the cryotrap, the
temperature of the transfer line from the cryotrap to the GC, and the GC
oven temperature. Table 1 shows that higher peak area and peak height were
observed for higher GC oven, valve oven, and transfer line temperatures, up
to 200 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. These temperatures were optimized for HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, and
additional work is needed to determine optimal system temperatures for other
Hg compounds.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <title>Cryogenic preconcentrator</title>
      <p>Results of cryotrap cooling temperature tests are given in Table 2. While
cryotrap cooling temperatures of 0 and <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>25 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C
resulted in similar peak areas, peak heights were greater with 0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, probably because the higher temperature allowed for more rapid desorption
when the cryotrap was heated. Peak area and shape deteriorated at cryotrap
cooling temperatures above 0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. When analyzing ambient air
samples, cryotrapping temperatures slightly above 0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C may be
ideal, since they would allow for efficient trapping of Hg compounds, but
allow water to pass through. While HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> peaks were smaller when the
cryotrap was cooled to <inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>50 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, this lower temperature allowed the
cryotrap to efficiently collect Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> as well (data not shown).</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><caption><p>GC/MS results from permeation of HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> with varying cryotrap
cooling and desorption temperatures. Each iteration was performed at least
in duplicate to verify the consistency of results. Peak area and height are
for <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 362.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="center"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Cryotrap cooling</oasis:entry>  
         <oasis:entry colname="col2">Retention</oasis:entry>  
         <oasis:entry colname="col3">Peak</oasis:entry>  
         <oasis:entry colname="col4">Peak</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">temp. (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>  
         <oasis:entry colname="col2">time</oasis:entry>  
         <oasis:entry colname="col3">area</oasis:entry>  
         <oasis:entry colname="col4">height</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>50</oasis:entry>  
         <oasis:entry colname="col2">4.21</oasis:entry>  
         <oasis:entry colname="col3">104 386</oasis:entry>  
         <oasis:entry colname="col4">4789</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>25</oasis:entry>  
         <oasis:entry colname="col2">4.22</oasis:entry>  
         <oasis:entry colname="col3">137 471</oasis:entry>  
         <oasis:entry colname="col4">7206</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">0</oasis:entry>  
         <oasis:entry colname="col2">4.14</oasis:entry>  
         <oasis:entry colname="col3">134 462</oasis:entry>  
         <oasis:entry colname="col4">8623</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">5</oasis:entry>  
         <oasis:entry colname="col2">4.14</oasis:entry>  
         <oasis:entry colname="col3">117 864</oasis:entry>  
         <oasis:entry colname="col4">8272</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">10</oasis:entry>  
         <oasis:entry colname="col2">4.12</oasis:entry>  
         <oasis:entry colname="col3">113 516</oasis:entry>  
         <oasis:entry colname="col4">7589</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">30</oasis:entry>  
         <oasis:entry colname="col2">4.13</oasis:entry>  
         <oasis:entry colname="col3">39 526</oasis:entry>  
         <oasis:entry colname="col4">1583</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Cryotrap desorb</oasis:entry>  
         <oasis:entry namest="col2" nameend="col4" align="center">  </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">temp. (<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C)</oasis:entry>  
         <oasis:entry namest="col2" nameend="col4" align="center">  </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">170</oasis:entry>  
         <oasis:entry colname="col2">3.35</oasis:entry>  
         <oasis:entry colname="col3">83 198</oasis:entry>  
         <oasis:entry colname="col4">8582</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">200</oasis:entry>  
         <oasis:entry colname="col2">4.14</oasis:entry>  
         <oasis:entry colname="col3">101 757</oasis:entry>  
         <oasis:entry colname="col4">8557</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">220</oasis:entry>  
         <oasis:entry colname="col2">3.36</oasis:entry>  
         <oasis:entry colname="col3">173 059</oasis:entry>  
         <oasis:entry colname="col4">17 501</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">240</oasis:entry>  
         <oasis:entry colname="col2">3.377</oasis:entry>  
         <oasis:entry colname="col3">175 723</oasis:entry>  
         <oasis:entry colname="col4">17 567</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p>Hotter cryotrap desorption temperatures resulted in better peak areas for
HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> (Table 2), with a desorption temperature of 240 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C
resulting in the best peak area and peak shape. Hotter desorption
temperatures likely resulted in more rapid volatilization of HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> from
the cryotrap, leading to improved peak shape.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <title>Chromatographic columns</title>
      <p>Of the three columns we tested for transmission of HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, we only
observed HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> peaks with the Rxi-5Sil MS column or the SPB-Octyl
column. We observed consistent HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> peaks with the Rxi-1ms column.
Babko et al. (2001) observed HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> peaks with a low-polarity column similar to the RXi-5Sil MS column we used (DB-5; 5 %
diphenyl/95 % dimethyl polysiloxane). Olson et al. (2002) only
observed Hg compound peaks when using a 30 m non-polar phase column (DB1;
100 % dimethyl polysiloxane) similar to the Rxi-1ms column we used.
Olson et al. (2002) were not able to observe Hg peaks with more
polar columns that had polyethylene glycol, cyanopropyl phenyl, or
trifluoropropyl phases.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><caption><p>Chromatogram (above) and mass spectrum at 2.92 min (below) of
HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> emitted from a permeation tube. The <inline-formula><mml:math display="inline"><mml:mi>Y</mml:mi></mml:math></inline-formula> axis shows the mass
spectrometer's ion current intensity. The box on the bottom right compares the
expected HgBr<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> mass spectrum (from de
Laeter et al., 2004) to the observed spectrum.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016-f04.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS4">
  <title>Hg compound detection</title>
      <p>The permeation rate for HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, determined by the pyrolyzer and Tekran
analyzer system, was 37 pg s<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. After incorporating the optimizations
reported above, and after further optimizing the parameters of the mass
spectrometer, permeation of 22.2 ng of HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> resulted in a peak area of
1 788 451 and a peak height of 143 238 when the MS was operated in selected
ion mode for <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 362 (Fig. 4). The HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> detection limit for the
optimized system in selected ion mode, calculated as 3 times the
standard deviation of replicate low-concentration samples, was 90 pg. The
detection limit in scan mode was 300 pg.</p>
      <p>A small, poorly formed Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> peak was often observed prior to Hg halide
peaks in chromatograms (see <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 202 trace in top of Fig. 4). This Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>
peak was probably the result of breakdown of Hg halides to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> within
the chromatographic column, and its poor shape can be explained by continued
breakdown as Hg halides moved through the column. The small size of the peak
relative to the Hg halide peak is an indicator that Hg halide decomposition
in the column was limited. Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> chromatographic peaks during Hg halide
injections were not likely the result of Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> emitted from permeation
tubes, since any Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> emitted or formed prior to the cryotrap would have
passed through the cryotrap at its typical collection temperature of
0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C.</p>
      <p>While Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> was detected from Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and HgO-containing
permeation tubes (when the cryotrap cooling temperature was lowered to
<inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>50 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C), we were unable to observe unequivocal Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
or HgO mass spectra when analyzing the output of these permeation tubes with
the GC/MS. A consistent peak with a prominent 218 <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> signal was observed at
a retention time of about 10 min when Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> or HgO was
permeated (Fig. 5). While <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 218 is the most abundant expected mass for
HgO<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>, the observed isotope pattern did not indicate Hg. Instead, the
mass spectrum for this peak was similar to mass spectra for siloxanes,
indicating column or tubing degradation as the source. The absence of Hg in
this peak was confirmed by the lack of an Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> signal at <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 202 (Fig. 5).</p>
      <p>Lyman et al. (2009) constructed HgO permeation tubes and found
that, along with Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>, an Hg compound was emitted from these tubes that
could be collected and analyzed using KCl-coated denuders or cation-exchange
membranes. Huang et al. (2013a) showed that, when collected on nylon
membranes, the Hg compound emitted from HgO permeation tubes exhibited a
thermal desorption profile that was different from those exhibited by
HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, and Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>. They showed that Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
permeation tubes also emit a reactive Hg compound. It is not known, however,
whether the Hg compound emitted from HgO permeation tubes is HgO. Huang
et al. (2013a) proposed that the emitted compound could be Hg<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O.
Regardless of the chemical identity of the compound, it is possible that we
were not able to detect it because it degraded within the system tubing,
valves, or the chromatographic column. The GC/MS did not report any Hg
signal, including Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>, when analyzing the output from HgO and
Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> permeation tubes with a cryotrap temperature of
0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C. This indicates either (1) the Hg compound emitted from these
permeation tubes degraded prior to or within the cryotrap, allowing Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>
to pass through the cryotrap and out of the system; (2) the emitted Hg
compound is too volatile to collect on a cryotrap at 0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C, or (3) the
emitted Hg compound becomes permanently bound to some part of the
analytical system and does not degrade. System temperatures and materials
were optimized for HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, and different materials and/or a different
temperature regime may improve detection for compounds emitted from HgO and
Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> permation tubes.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><caption><p>Chromatogram (above) and mass spectrum at 10.10 min (below)
generated from analysis of 34 ng Hg emitted from an HgO permeation tube. The
box on the bottom right compares the expected HgO<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> mass spectrum (from
de Laeter et al., 2004) to the observed spectrum.
While the prominent mass peak was <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 218, the observed isotope pattern does
not indicate HgO<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016-f05.png"/>

        </fig>

      <p>We introduced small quantities of HgO and Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (separately)
into the direct injection probe on the MS to determine a mass spectrum for
these compounds. Figure 6 shows these mass spectra. Only Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> was
observed from the direct injection of HgO, and no significant signal was
observed around <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 218 (HgO<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> or <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 420 (Hg<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>O<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. This could
be because (1) HgO is not volatile enough to produce enough vapor in the
ionization chamber of the MS to result in a detectable signal, so only
off-gassed Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula> was observed (as Hg<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> or (2) the ionization energy
of the MS was so strong that all HgO was broken down to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> within the
ionization chamber. HgO<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> was observed, however, when Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
was inserted into the direct probe, probably as a breakdown product. This
provides evidence that the MS could detect HgO as HgO<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> if it did indeed
exist in the gas phase. The fact that it was not detected when solid HgO was
inserted into the direct probe may indicate that HgO does not have an
appreciable gas phase. If this is the case, it is not clear what is emitted
from HgO permeation tubes that can be collected on nylon membranes and
KCl-coated denuders (Huang et al., 2013a).</p>
      <p>The mass spectrum for Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> showed Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msubsup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>
(<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 326) and several breakdown products, including HgNO<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn><mml:mo>+</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula>
264), and HgO<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>+</mml:mo></mml:msup></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 218). A cluster of peaks around <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 343 was also
observed and could be interpreted as the monohydrate of Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.
Olson et al. (2002) dissolved Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in acetonitrile
and interpreted resultant mass spectra to be caused by reaction of
Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with column material, producing CH<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>HgCl. Our direct
probe results suggest the existence of gas-phase Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and do
not match the spectra presented by Olson et al. (2002).</p>
</sec>
<sec id="Ch1.S3.SS5">
  <title>Laboratory tests of sample collection materials</title>
      <p>We permeated Hg compounds onto nylon membranes and into PDMS foam-filled
tubes, quartz wool-filled tubes, and deactivated fused silica-coated tubes
and used the sample desorption oven to transmit collected Hg compounds onto
the cryotrap and then into the GC/MS. When we heated nylon membranes to
100 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C or greater in the desorption oven, the prominent observed
peak was consistent with dodecanoic acid, a potential degradation product of
the nylon material (Carraher, 2014). Dodecanoic acid exhibits prominent
peaks at and near <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 200, and the dodecanoic acid peak intensity was so
high as to obscure any Hg peaks when loaded in the laboratory or when
sampling ambient air. Huang et al. (2013a) used nylon membranes to
collect Hg compounds and desorbed those compounds into a pyrolyzer and
atomic fluorescence analyzer. The atomic fluorescence instrument only
detects Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>, however, so interference from nylon breakdown products was
not an issue.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><caption><p>Mass spectrum for Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (above) and HgO (below)
derived from direct probe injection into the MS. The boxes at top left in
each pane compare the expected indicated mass spectrum (from
de Laeter et al., 2004) to the observed spectrum.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016-f06.png"/>

        </fig>

      <p>Like nylon membranes, PDMS foam-filled tubes also had too much interference
to allow for detection of Hg compounds, even when loaded with as much as 60
ng HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>.</p>
      <p>Quartz wool-filled PFA tubes exhibited less interference and clearly
identifiable Hg halide signals (Fig. 7). However, chromatograms from quartz
wool-filled tubes had poorly shaped peaks and substantial non-Hg signal. The
cause of the poorly shaped peaks is not known. Quartz particles could have
accumulated in the cryotrap, causing a slow desorption of Hg compounds
during cryotrap heating. If this occurred, the quartz particles were
apparently cleaned out after each analysis, since we performed injections of
Hg halides directly from the permeation oven onto the cryotrap subsequent to
quartz wool analyses and observed normal chromatographic peaks.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><caption><p>Chromatogram (above) and mass spectrum at 5.6 min (below) of
HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> permeated onto quartz wool-filled PFA tubing, then desorbed into
the GC/MS system.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/2195/2016/amt-9-2195-2016-f07.png"/>

        </fig>

      <p>While HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> was loaded onto a quartz wool-filled tube for the analysis
shown in Fig. 7, the figure shows some HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> signal in the mass
spectrum. The quartz wool-filled tube had previously been loaded with
HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, and some residual HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> apparently remained in the tube.
Additionally, a cluster of masses centered at <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>/</mml:mo><mml:mi>z</mml:mi></mml:mrow></mml:math></inline-formula> 316, corresponding with HgBrCl,
can be clearly observed in the mass spectrum. The same cluster of masses can
be seen in part B of Fig. 2 and in Fig. 4. HgBrCl could exist because of (1) a
reaction between HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> in the acetone solution in Fig. 2
or on the quartz wool in Fig. 7, or (2) it could be a contaminant in the
commercial Hg halide compounds used in this study.<?xmltex \hack{\newpage}?></p>
      <p>The deactivated fused silica-coated stainless steel tube collected
HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> with no discernable non-Hg interference, but the amount of
HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> collected was low, probably because of high breakthrough.
Deactivated fused silica-coated tubing may be a viable HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> collection
device if a device with larger surface area is used and/or if the tubing is
cooled to a temperature that limits Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> breakthrough.</p>
</sec>
<sec id="Ch1.S3.SS6">
  <title>Ambient air sample collection</title>
      <p>The location, duration, and methods used for ambient air sample collection
are given in Methods. None of the ambient air samples collected using quartz
wool-filled tubes or nylon membranes resulted in any detectable Hg
compounds. Low Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> concentrations in ambient air could have led to a
sampled Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> mass below the detection limits of the GC/MS. 10.1 m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>
of ambient air was sampled by each nylon membrane, and 5.4 m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> of air
was sampled by each quartz wool-filled tube. These sampling volumes are
adequate to collect 100 pg Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> (within the detection limit of the
GC/MS) if ambient Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> was 10 and 18 pg m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, respectively. Not all
ambient air sample collections were associated with alternative Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula>
measurements, but for quartz wool-filled tube collection at the University
of Nevada, Reno, Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> (measured by a Tekran 2537/1130/1135 speciation
system as the sum of Hg collected on the system's denuder and particulate
filter) was 38 <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> 9 pg m<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (mean <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>95 % confidence
interval). However, some breakthrough may have occurred through the sample
collection devices, and the non-Hg interference caused by the sample
collection devices likely increased the actual detection limit for these
samples. Alternatively, it is possible that the Hg compounds in sampled
ambient air were not Hg halides and were undetectable by the GC/MS system.</p>
</sec>
<sec id="Ch1.S3.SS7">
  <title>Future work</title>
      <p>Improvements to the MS used in this work may increase its sensitivity for Hg
compounds and decrease the detection limits of our system. Deeds et al. (2015)
reported detection limits of 6–40 pg for HgCl<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>
with an atmospheric pressure chemical ionization MS, and pointed out that
chemical ionization is likely to decrease detection limits relative to
electron impact ionization. The system used by Deeds et al. (2015),
however, suffered from interference from non-Hg compounds found in ambient
air because it did not utilize chromatographic separation. Our GC system,
coupled with chemical ionization MS, may be able to achieve improved ambient
air detection limits while maintaining the ability to separate individual Hg
compounds and separate Hg compounds from non-Hg atmospheric constituents.</p>
      <p>Interference in mass spectra created by collection materials likely limited
our ability to detect Hg compounds in ambient air. Testing of additional
collection materials is needed. Deeds et al. (2015) used shredded Teflon
packed in tubes to collect Hg halides, and they did not note any
interference from these materials. We found no interference from deactivated
fused silica-coated stainless steel tubing. Highly inert surfaces like these
are ideal because they do not result in off-gasing that may interfere with
mass spectra. However, Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> may not collect efficiently on these
surfaces unless they are cooled to 0 <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C or lower. In addition,
Lyman et al. (2010b) reported that ozone reduces Hg halides
collected on uncoated quartz traps to Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">0</mml:mn></mml:msup></mml:math></inline-formula>, and highly inert surfaces
may also leave Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> exposed to reaction with ozone or other atmospheric
constituents.</p>
      <p>We observed poor results from tubes packed with PDMS foam, but saw little
interference from the PDMS-coated chromatographic column (for Hg halides).
PDMS in chromatographic columns is cross-linked to stabilize it and is less
likely to decompose. PDMS denuders have been used successfully to
preconcentrate a wide variety of compounds (Burger et al., 1991; Dudek et
al., 2002), including semivolatiles (Rowe and Perlinger, 2010).
PDMS may also shield analytes from atmospheric oxidants that have low
affinity for the PDMS phase (possibly including ozone) (Rowe and
Perlinger, 2010).</p>
      <p>While the GC/MS system in this study was able to separate and quantitatively
analyze Hg halides, we have not yet shown that it can detect non-halide Hg
compounds, including Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and HgO. HgO may not exist in the
gas phase, but Hg(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is likely to be non-polar, as are Hg
halides (Goodsite et al., 2004), and likely can exist in the gas phase.
HgBrX compounds, including HgBrOH, may exist in the atmosphere
(Weiss-Penzias et al., 2015). HgBrOH, unlike HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, has an
appreciable dipole moment (Goodsite et al., 2004) and may have different
reactivity and volatility than HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>. Our system is able to detect
HgBrCl, so it could possibly identify other bromine-containing Hg compounds,
but this has not been tested. System temperatures and materials may need to
be optimized for individual compounds or groups of compounds. Different Hg
compounds may perform better with different columns, as shown by
Babko et al. (2001). Finally, replacement of VICI valves
(which have Valcon rotors that may react with Hg compounds) with
all-stainless steel valves that can be coated with deactivated fused silica
may improve system performance for Hg compounds that are more reactive than
Hg halides.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <title>Summary</title>
      <p>Identification of atmospheric Hg<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mtext>II</mml:mtext></mml:msup></mml:math></inline-formula> is needed to improve understanding
of Hg chemistry and biogeochemical cycling. The GC/MS-based system described
here has a detection limit low enough to identify and quantify Hg halides in
the ambient atmosphere, but better atmospheric sampling materials are needed
to accomplish this. Work is ongoing to continue its development, including
improving ambient air collection options, increasing the number of compounds
it can reliably detect, and improving instrument sensitivity.</p>
</sec>

      
      </body>
    <back><app-group>
        <supplementary-material position="anchor"><p><bold>The Supplement related to this article is available online at <inline-supplementary-material xlink:href="http://dx.doi.org/10.5194/amt-9-2195-2016-supplement" xlink:title="pdf">doi:10.5194/amt-9-2195-2016-supplement</inline-supplementary-material>.</bold></p></supplementary-material>
        </app-group><ack><title>Acknowledgements</title><p>Funding for this work was provided by US National Science Foundation award
number 1324781 and the Electric Power Research Institute. We are grateful to
Mae Gustin, Jiaoyan Huang, and Matthieu Miller at the University of Nevada,
Reno, for collecting some of the ambient air samples used in this study and
to Mae Gustin for providing helpful comments on the manuscript.
<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?>
Edited by: P. Herckes</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>
Ariya, P. A., Peterson, K., Snider, G., and Amyot, M.: Mercury chemical
transformations in the gas, aqueous and heterogeneous phases:
state-of-the-art science and uncertainties, in: Mercury Fate and Transport in
the Global Atmosphere, edited by: Mason, R. and Pirrone, N., Springer, New York,
NY, USA, 2009.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>
Babko, S. V., Monttgomery, J. L., Battleson, D. M., Whitworth, C. G., Sears,
J., Summer, J., and Gingery, D.: Mercury Speciation Analysis by Gas
Chromatography/Electron Impact/Mass Spectrometry, Waste Management
Conference, 25 February–1 March 2001, Tucson, AZ, USA, 2001.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>
Burger, B. V., Roux, M. L., Munro, Z. M., and Wilken, M. E.: Production and
use of capillary traps for headspace gas chromatography of airborne volatile
organic compounds, 18th International symposium on chromatography part I,
552, 137–151, 1991.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>
Calvert, J. G. and Lindberg, S. E.: Mechanisms of mercury removal by O-3 and
OH in the atmosphere, Atmos. Environ., 39, 3355–3367, 2005.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>
Carraher, C.: Carraher's Polymer Chemistry, 9th Edition, CRC Press, Boca
Raton, FL, USA, 2014.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Cavalheiro, J., Preud'homme, H., Amouroux, D., Tessier, E., and Monperrus,
M.: Comparison between GC-MS and GC-ICPMS using isotope dilution for the
simultaneous monitoring of inorganic and methyl mercury, butyl and phenyl
tin compounds in biological tissues, Anal. Bioanal. Chem.,
406, 1253–1258, 2014.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>
Deeds, D. A., Ghoshdastidar, A., Raofie, F., Gueìrette, E. A.,
Tessier, A., and Ariya, P. A.: Development of a Particle-Trap
Preconcentration-Soft Ionization Mass Spectrometric Technique for the
Quantification of Mercury Halides in Air, Anal. Chem., 87, 5109–5116, 2015.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
de Laeter, J. R., Böhlke, J. K., De Bièvre, P., Hidaka, H., Peiser,
H. S., Rosman, K. J. R., and Taylor, P. D. P.: Atomic weights of the
elements: Review 2000 (IUPAC Technical Report), Pure Appl. Chem., 75,
683–800, 2004.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
dos Santos, J. S., de la Guardia, M., Pastor, A., and dos Santos, M. L. P.:
Determination of organic and inorganic mercury species in water and sediment
samples by HPLC on-line coupled with ICP-MS, Talanta, 80, 207–211, 2009.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>
Dudek, M., Kloskowski, A., Wolska, L., Pilarczyk, M., and Namiesnik, J.:
Using different types of capillary chromatographic columns as denudation
traps: a comparison of sorption properties, J. Chromatogr. A,
977, 115–123, 2002.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Eagles-Smith, C. A. and Ackerman, J. T.: Mercury bioaccumulation in
estuarine wetland fishes: Evaluating habitats and risk to coastal wildlife,
Environ. Pollut., 193, 147–155, 2014.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>
Galbreath, K. C. and Zygarlicke, C. J.: Mercury transformations in coal
combustion flue gas, Fuel Process. Technol., 65, 289–310, 2000.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>Goodsite, M. E., Plane, J., and Skov, H.: A theoretical study of the
oxidation of Hg0 to HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> in the troposphere, Environ. Sci. Technol., 38, 1772-1776, 2004.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>
Gratz, L., Ambrose, J., Jaffe, D., Shah, V., Jaeglé, L., Stutz, J.,
Festa, J., Spolaor, M., Tsai, C., and Selin, N.: Oxidation of mercury by
bromine in the subtropical Pacific free troposphere, Geophys. Res. Lett., 42, 10494–10502, 2015.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Gustin, M. S., Lindberg, S. E., and Weisberg, P. J.: An update on the
natural sources and sinks of atmospheric mercury, Appl.Geochem., 23,
482–493, 2008.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>
Gustin, M. S., Huang, J., Miller, M. B., Peterson, C., Jaffe, D. A.,
Ambrose, J., Finley, B. D., Lyman, S. N., Call, K., and Talbot, R.: Do we
understand what the mercury speciation instruments are actually measuring?
Results of RAMIX, Environ. Sci. Technol., 47, 7295–7306,
2013a.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>
Gustin, M. S., Huang, J. Y., Miller, M. B., Peterson, C., Jaffe, D. A.,
Ambrose, J., Finley, B. D., Lyman, S. N., Call, K., Talbot, R., Feddersen,
D., Mao, H. T., and Lindberg, S. E.: Do We Understand What the Mercury
Speciation Instruments Are Actually Measuring? Results of RAMIX,
Environ. Sci. Technol., 47, 7295–7306, 2013b.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>
Hedgecock, I. M. and Pirrone, N.: Chasing quicksilver: Modeling the
atmospheric lifetime of Hg0 (g) in the marine boundary layer at various
latitudes, Environ. Sci. Technol., 38, 69–76, 2004.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>
Holmes, C. D.: Atmospheric chemistry: Quick cycling of quicksilver, Nat.
Geosci., 5, 95–96, 2012.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>Holmes, C. D., Jacob, D. J., and Yang, X.: Global lifetime of elemental
mercury against oxidation by atomic bromine in the free troposphere,
Geophys. Res. Lett., 33, L20808, <ext-link xlink:href="http://dx.doi.org/10.1029/2006GL027176" ext-link-type="DOI">10.1029/2006GL027176</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>Holmes, C. D., Jacob, D. J., Corbitt, E. S., Mao, J., Yang, X., Talbot, R.,
and Slemr, F.: Global atmospheric model for mercury including oxidation by
bromine atoms, Atmos. Chem. Phys., 10, 12037–12057,
<ext-link xlink:href="http://dx.doi.org/10.5194/acp-10-12037-2010" ext-link-type="DOI">10.5194/acp-10-12037-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>
Huang, J. and Gustin, M. S.: Uncertainties of Gaseous Oxidized Mercury
Measurements Using KCl-Coated Denuders, Cation-Exchange Membranes, and Nylon
Membranes: Humidity Influences, Environ. Sci. Technol., 49,
6102–6108, 2015.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>
Huang, J., Miller, M. B., Weiss-Penzias, P., and Gustin, M. S.: Comparison
of gaseous oxidized Hg measured by KCl-coated denuders, and nylon and cation
exchange membranes, Environ. Sci. Technol., 47, 7307–7316,
2013a.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>
Huang, J. Y., Miller, M. B., Weiss-Penzias, P., and Gustin, M. S.:
Comparison of Gaseous Oxidized Hg Measured by KCl-Coated Denuders, and Nylon
and Cation Exchange Membranes, Environ. Sci. Technol., 47,
7307–7316, 2013b.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>
Hynes, A. J., Donohoue, D. L., Goodsite, M. E., and Hedgecock, I. M.: Our
current understanding of major chemical and physical processes affecting
mercury dynamics in the atmosphere and at the air-water/terrestrial
interfaces, in: Mercury Fate and Transport in the Global Atmosphere, edited by: Mason,
R. and Pirrone, N., Springer, New York, NY, USA, 2009.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>
Jaffe, D. A., Lyman, S., Amos, H. M., Gustin, M. S., Huang, J. Y., Selin, N.
E., Levin, L., ter Schure, A., Mason, R. P., Talbot, R., Rutter, A., Finley,
B., Jaegle, L., Shah, V., McClure, C., Arnbrose, J., Gratz, L., Lindberg,
S., Weiss-Penzias, P., Sheu, G. R., Feddersen, D., Horvat, M., Dastoor, A.,
Hynes, A. J., Mao, H. T., Sonke, J. E., Slemr, F., Fisher, J. A., Ebinghaus,
R., Zhang, Y. X., and Edwards, G.: Progress on Understanding Atmospheric
Mercury Hampered by Uncertain Measurements, Environ. Sci. Technol., 48, 7204–7206, 2014.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>
Johnson, D. L. and Braman, R. S.: Distribution of atmospheric mercury
species near ground, Environ. Sci. Technol., 8, 1003–1009,
1974.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>Laurier, F. J. G., Mason, R. P., Whalin, L., and Kato, S.: Reactive gaseous
mercury formation in the North Pacific Ocean's marine boundary layer: A
potential role of halogen chemistry, J. Geophys. Res.-Atmos., 108, 4529,
<ext-link xlink:href="http://dx.doi.org/10.1029/2003JD003625" ext-link-type="DOI">10.1029/2003JD003625</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>
Lin, C. J., Pongprueksa, P., Lindberg, S. E., Pehkonen, S. O., Byun, D., and
Jang, C.: Scientific uncertainties in atmospheric mercury models I: Model
science evaluation, Atmos. Environ., 40, 2911–2928, 2006.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
Lindberg, S., Bullock, R., Ebinghaus, R., Engstrom, D., Feng, X. B.,
Fitzgerald, W., Pirrone, N., Prestbo, E., and Seigneur, C.: A synthesis of
progress and uncertainties in attributing the sources of mercury in
deposition, Ambio, 36, 19–32, 2007.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>
L'Vov, B. V.: Kinetics and mechanism of thermal decomposition of mercuric
oxide, Thermochim. Acta, 333, 21–26, 1999.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>
Lyman, S. N. and Gustin, M. S.: Speciation of atmospheric mercury at two
sites in northern Nevada, USA, Atmos. Environ., 42, 927–939, 2008.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>
Lyman, S. N. and Jaffe, D. A.: Formation and fate of oxidized mercury in the
upper troposphere and lower stratosphere, Nat. Geosci., 5, 114–117,
2012.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>
Lyman, S. N., Gustin, M. S., Prestbo, E. M., and Marsik, F. J.: Estimation
of Dry Deposition of Atmospheric Mercury in Nevada by Direct and Indirect
Methods, Environ. Sci. Technol., 41, 1970–1976, 2007.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>
Lyman, S. N., Gustin, M. S., Prestbo, E. M., Kilner, P. I., Edgerton, E.,
and Hartsell, B.: Testing and Application of Surrogate Surfaces for
Understanding Potential Gaseous Oxidized Mercury Dry Deposition,
Environ. Sci. Technol., 43, 6235–6241, 2009.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>
Lyman, S. N., Gustin, M. S., and Prestbo, E. M.: A passive sampler for
ambient gaseous oxidized mercury concentrations, Atmos. Environ.,
44, 246–252, 2010a.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>Lyman, S. N., Jaffe, D. A., and Gustin, M. S.: Release of mercury halides
from KCl denuders in the presence of ozone, Atmos. Chem. Phys., 10,
8197–8204, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-10-8197-2010" ext-link-type="DOI">10.5194/acp-10-8197-2010</ext-link>, 2010b.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><mixed-citation>
Malcolm, E. G. and Keeler, G. J.: Evidence for a sampling artifact for
particulate-phase mercury in the marine atmosphere, Atmos. Environ., 41,
3352–3359, 2007.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation>McClure, C. D., Jaffe, D. A., and Edgerton, E. S.: Evaluation of the KCl
denuder method for gaseous oxidized mercury using HgBr<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> at an in-service
AMNet site, Environ. Sci. Technol., 48, 11437–11444, 2014.</mixed-citation></ref>
      <ref id="bib1.bib40"><label>40</label><mixed-citation>
Obrist, D., Tas, E., Peleg, M., Matveev, V., Fain, X., Asaf, D., and Luria,
M.: Bromine-induced oxidation of mercury in the mid-latitude atmosphere, Nat.
Geosci., 4, 22–26, 2011.</mixed-citation></ref>
      <ref id="bib1.bib41"><label>41</label><mixed-citation>
Olson, E. S., Sharma, R. K., and Pavlish, J. H.: On the analysis of mercuric
nitrate in flue gas by GC-MS, Anal. Bioanal. Chem., 374, 1045–1049, 2002.</mixed-citation></ref>
      <ref id="bib1.bib42"><label>42</label><mixed-citation>
Pacyna, E. G., Pacyna, J. M., Steenhuisen, F., and Wilson, S.: Global
anthropogenic mercury emission inventory for 2000, Atmos. Environ., 40,
4048–4063, 2006.</mixed-citation></ref>
      <ref id="bib1.bib43"><label>43</label><mixed-citation>
Pal, B. and Ariya, P. A.: Gas-phase HO center dot-Initiated reactions of
elemental mercury: Kinetics, product studies, and atmospheric implications,
Environ. Sci. Technol., 38, 5555–5566, 2004a.</mixed-citation></ref>
      <ref id="bib1.bib44"><label>44</label><mixed-citation>
Pal, B. and Ariya, P. A.: Studies of ozone initiated reactions of gaseous
mercury: kinetics, product studies, and atmospheric implications, Phys. Chem.
Chem. Phys., 6, 572–579, 2004b.</mixed-citation></ref>
      <ref id="bib1.bib45"><label>45</label><mixed-citation>
Peleg, M., Tas, E., Matveev, V., Obrist, D., Moore, C. W., Gabay, M., and
Luria, M.: Observational evidence for involvement of nitrate radicals in
nighttime oxidation of mercury, Environ. Sci. Technol., 49, 14008–14018, 2015.</mixed-citation></ref>
      <ref id="bib1.bib46"><label>46</label><mixed-citation>Peterson, S. H., Ackerman, J. T., and Costa, D. P.: Marine foraging ecology
influences mercury bioaccumulation in deep-diving northern elephant seals, P.
Roy. Soc, B-Biol. Sci., 282, 26085591, <ext-link xlink:href="http://dx.doi.org/10.1098/rspb.2015.0710" ext-link-type="DOI">10.1098/rspb.2015.0710</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib47"><label>47</label><mixed-citation>
Rowe, M. D. and Perlinger, J. A.: Performance of a High Flow Rate, Thermally
Extractable Multicapillary Denuder for Atmospheric Semivolatile Organic
Compound Concentration Measurement, Environ. Sci. Technol., 44, 2098–2104,
2010.</mixed-citation></ref>
      <ref id="bib1.bib48"><label>48</label><mixed-citation>
Schroeder, W. H., Anlauf, K. G., Barrie, L. A., Lu, J. Y., Steffen, A.,
Schneeberger, D. R., and Berg, T.: Arctic springtime depletion of mercury,
Nature, 394, 331–332, 1998.</mixed-citation></ref>
      <ref id="bib1.bib49"><label>49</label><mixed-citation>Seigneur, C., Wrobel, J., and Constantinou, E.: A chemical kinetic mechanism
for atmospheric inorganic mercury, Environ. Sci. Technol., 28, 1589–1597,
1994. </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib50"><label>50</label><mixed-citation>
Seigneur, C., Vijayaraghavan, K., Lohman, K., Karamchandani, P., and Scott,
C.: Global source attribution for mercury deposition in the United States,
Environ. Sci. Technol., 38, 555–569, 2004.</mixed-citation></ref>
      <ref id="bib1.bib51"><label>51</label><mixed-citation>
Selin, N. E.: Global Biogeochemical Cycling of Mercury: A Review, Annu. Rev.
Env. Resour., 34, 43–63, 2009.</mixed-citation></ref>
      <ref id="bib1.bib52"><label>52</label><mixed-citation>
Shepler, B. C. and Peterson, K. A.: Mercury monoxide: A systematic
investigation of its ground electronic state, J. Phys. Chem. A, 107,
1783–1787, 2003.</mixed-citation></ref>
      <ref id="bib1.bib53"><label>53</label><mixed-citation>Slemr, F., Ebinghaus, R., Brenninkmeijer, C. A. M., Hermann, M., Kock, H. H.,
Martinsson, B. G., Schuck, T., Sprung, D., van Velthoven, P., Zahn, A., and
Ziereis, H.: Gaseous mercury distribution in the upper troposphere and lower
stratosphere observed onboard the CARIBIC passenger aircraft, Atmos. Chem.
Phys., 9, 1957–1969, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-9-1957-2009" ext-link-type="DOI">10.5194/acp-9-1957-2009</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib54"><label>54</label><mixed-citation>
Sommar, J., Hallquist, M., Ljungstrom, E., and Lindqvist, O.: On the gas
phase reactions between volatile biogenic mercury species and the nitrate
radical, J. Atmos. Chem., 27, 233–247, 1997.</mixed-citation></ref>
      <ref id="bib1.bib55"><label>55</label><mixed-citation>Sprovieri, F., Pirrone, N., Ebinghaus, R., Kock, H., and Dommergue, A.:
Corrigendum to “A review of worldwide atmospheric mercury measurements”
published in Atmos. Chem. Phys., 10, 8245–8265, 2010, Atmos. Chem. Phys., 10,
8531–8531, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-10-8531-2010" ext-link-type="DOI">10.5194/acp-10-8531-2010</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bib56"><label>56</label><mixed-citation>Steffen, A., Douglas, T., Amyot, M., Ariya, P., Aspmo, K., Berg, T.,
Bottenheim, J., Brooks, S., Cobbett, F., Dastoor, A., Dommergue, A.,
Ebinghaus, R., Ferrari, C., Gardfeldt, K., Goodsite, M. E., Lean, D.,
Poulain, A. J., Scherz, C., Skov, H., Sommar, J., and Temme, C.: A synthesis
of atmospheric mercury depletion event chemistry in the atmosphere and snow,
Atmos. Chem. Phys., 8, 1445–1482, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-8-1445-2008" ext-link-type="DOI">10.5194/acp-8-1445-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib57"><label>57</label><mixed-citation>Talbot, R., Mao, H., Scheuer, E., Dibb, J., and Avery, M.: Total depletion
of Hg degree in the upper troposphere-lower stratosphere, Geophys.
Res. Lett., 34, L23804, <ext-link xlink:href="http://dx.doi.org/10.1029/2007GL031366" ext-link-type="DOI">10.1029/2007GL031366</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib58"><label>58</label><mixed-citation>
Tossell, J. A.: Calculation of the energetics for the oligomerization of gas
phase HgO and HgS and for the solvolysis of crystalline HgO and HgS, J. Phys. Chem. A, 110, 2571–2578, 2006.</mixed-citation></ref>
      <ref id="bib1.bib59"><label>59</label><mixed-citation>Wang, F., Saiz-Lopez, A., Mahajan, A. S., Gómez Martín, J. C., Armstrong, D.,
Lemes, M., Hay, T., and Prados-Roman, C.: Enhanced production of oxidised
mercury over the tropical Pacific Ocean: a key missing oxidation pathway,
Atmos. Chem. Phys., 14, 1323–1335, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-14-1323-2014" ext-link-type="DOI">10.5194/acp-14-1323-2014</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib60"><label>60</label><mixed-citation>Weiss-Penzias, P., Amos, H. M., Selin, N. E., Gustin, M. S., Jaffe, D. A.,
Obrist, D., Sheu, G.-R., and Giang, A.: Corrigendum to “Use of a global model
to understand speciated atmospheric mercury observations at five
high-elevation sites” published in Atmos. Chem. Phys., 15, 1161–1173, 2015,
Atmos. Chem. Phys., 15, 2225–2225, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-15-2225-2015" ext-link-type="DOI">10.5194/acp-15-2225-2015</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib61"><label>61</label><mixed-citation>
Widmer, N. C., West, J., and Cole, J. A.: Thermochemical study of mercury
oxidation, 93rd Annual Meeting of the Air and Waste Management Association, 18–22 June 2000, Salt Lake City, Utah, USA, 2000.</mixed-citation></ref>
      <ref id="bib1.bib62"><label>62</label><mixed-citation>
Wilcox, J. and Blowers, P.: Decomposition of Mercuric Chloride and
Application to Combustion Flue Gases, Environ. Chem., 1, 166–171,
2004.</mixed-citation></ref>

  </ref-list><app-group content-type="float"><app><title/>

    </app></app-group></back>
    <!--<article-title-html>Detection and quantification of gas-phase oxidized mercury compounds by
GC/MS</article-title-html>
<abstract-html><p class="p">Most mercury pollution is emitted to the atmosphere, and the
location and bioavailability of deposited mercury largely depends on poorly
understood atmospheric chemical reactions that convert elemental mercury
into oxidized mercury compounds. Current measurement methods do not speciate
oxidized mercury, leading to uncertainty about which mercury compounds exist
in the atmosphere and how oxidized mercury is formed. We have developed a
gas chromatography/mass spectrometry (GC-MS)-based system for identification and
quantification of atmospheric oxidized mercury compounds. The system
consists of an ambient air collection device, a thermal desorption module, a
cryofocusing system, a gas chromatograph, and an ultra-sensitive mass
spectrometer. It was able to separate and identify mercury halides with
detection limits low enough for ambient air collection (90 pg), but an
improved ambient air collection device is needed. The GC/MS system was unable to quantify HgO or Hg(NO<sub>3</sub>)<sub>2</sub>, and data collected cast doubt
upon the existence of HgO in the gas phase.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Ariya, P. A., Peterson, K., Snider, G., and Amyot, M.: Mercury chemical
transformations in the gas, aqueous and heterogeneous phases:
state-of-the-art science and uncertainties, in: Mercury Fate and Transport in
the Global Atmosphere, edited by: Mason, R. and Pirrone, N., Springer, New York,
NY, USA, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Babko, S. V., Monttgomery, J. L., Battleson, D. M., Whitworth, C. G., Sears,
J., Summer, J., and Gingery, D.: Mercury Speciation Analysis by Gas
Chromatography/Electron Impact/Mass Spectrometry, Waste Management
Conference, 25 February–1 March 2001, Tucson, AZ, USA, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Burger, B. V., Roux, M. L., Munro, Z. M., and Wilken, M. E.: Production and
use of capillary traps for headspace gas chromatography of airborne volatile
organic compounds, 18th International symposium on chromatography part I,
552, 137–151, 1991.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Calvert, J. G. and Lindberg, S. E.: Mechanisms of mercury removal by O-3 and
OH in the atmosphere, Atmos. Environ., 39, 3355–3367, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Carraher, C.: Carraher's Polymer Chemistry, 9th Edition, CRC Press, Boca
Raton, FL, USA, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Cavalheiro, J., Preud'homme, H., Amouroux, D., Tessier, E., and Monperrus,
M.: Comparison between GC-MS and GC-ICPMS using isotope dilution for the
simultaneous monitoring of inorganic and methyl mercury, butyl and phenyl
tin compounds in biological tissues, Anal. Bioanal. Chem.,
406, 1253–1258, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Deeds, D. A., Ghoshdastidar, A., Raofie, F., Gueìrette, E. A.,
Tessier, A., and Ariya, P. A.: Development of a Particle-Trap
Preconcentration-Soft Ionization Mass Spectrometric Technique for the
Quantification of Mercury Halides in Air, Anal. Chem., 87, 5109–5116, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
de Laeter, J. R., Böhlke, J. K., De Bièvre, P., Hidaka, H., Peiser,
H. S., Rosman, K. J. R., and Taylor, P. D. P.: Atomic weights of the
elements: Review 2000 (IUPAC Technical Report), Pure Appl. Chem., 75,
683–800, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
dos Santos, J. S., de la Guardia, M., Pastor, A., and dos Santos, M. L. P.:
Determination of organic and inorganic mercury species in water and sediment
samples by HPLC on-line coupled with ICP-MS, Talanta, 80, 207–211, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Dudek, M., Kloskowski, A., Wolska, L., Pilarczyk, M., and Namiesnik, J.:
Using different types of capillary chromatographic columns as denudation
traps: a comparison of sorption properties, J. Chromatogr. A,
977, 115–123, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Eagles-Smith, C. A. and Ackerman, J. T.: Mercury bioaccumulation in
estuarine wetland fishes: Evaluating habitats and risk to coastal wildlife,
Environ. Pollut., 193, 147–155, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Galbreath, K. C. and Zygarlicke, C. J.: Mercury transformations in coal
combustion flue gas, Fuel Process. Technol., 65, 289–310, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Goodsite, M. E., Plane, J., and Skov, H.: A theoretical study of the
oxidation of Hg0 to HgBr<sub>2</sub> in the troposphere, Environ. Sci. Technol., 38, 1772-1776, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Gratz, L., Ambrose, J., Jaffe, D., Shah, V., Jaeglé, L., Stutz, J.,
Festa, J., Spolaor, M., Tsai, C., and Selin, N.: Oxidation of mercury by
bromine in the subtropical Pacific free troposphere, Geophys. Res. Lett., 42, 10494–10502, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Gustin, M. S., Lindberg, S. E., and Weisberg, P. J.: An update on the
natural sources and sinks of atmospheric mercury, Appl.Geochem., 23,
482–493, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Gustin, M. S., Huang, J., Miller, M. B., Peterson, C., Jaffe, D. A.,
Ambrose, J., Finley, B. D., Lyman, S. N., Call, K., and Talbot, R.: Do we
understand what the mercury speciation instruments are actually measuring?
Results of RAMIX, Environ. Sci. Technol., 47, 7295–7306,
2013a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Gustin, M. S., Huang, J. Y., Miller, M. B., Peterson, C., Jaffe, D. A.,
Ambrose, J., Finley, B. D., Lyman, S. N., Call, K., Talbot, R., Feddersen,
D., Mao, H. T., and Lindberg, S. E.: Do We Understand What the Mercury
Speciation Instruments Are Actually Measuring? Results of RAMIX,
Environ. Sci. Technol., 47, 7295–7306, 2013b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Hedgecock, I. M. and Pirrone, N.: Chasing quicksilver: Modeling the
atmospheric lifetime of Hg0 (g) in the marine boundary layer at various
latitudes, Environ. Sci. Technol., 38, 69–76, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Holmes, C. D.: Atmospheric chemistry: Quick cycling of quicksilver, Nat.
Geosci., 5, 95–96, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Holmes, C. D., Jacob, D. J., and Yang, X.: Global lifetime of elemental
mercury against oxidation by atomic bromine in the free troposphere,
Geophys. Res. Lett., 33, L20808, <a href="http://dx.doi.org/10.1029/2006GL027176" target="_blank">doi:10.1029/2006GL027176</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
Holmes, C. D., Jacob, D. J., Corbitt, E. S., Mao, J., Yang, X., Talbot, R.,
and Slemr, F.: Global atmospheric model for mercury including oxidation by
bromine atoms, Atmos. Chem. Phys., 10, 12037–12057,
<a href="http://dx.doi.org/10.5194/acp-10-12037-2010" target="_blank">doi:10.5194/acp-10-12037-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Huang, J. and Gustin, M. S.: Uncertainties of Gaseous Oxidized Mercury
Measurements Using KCl-Coated Denuders, Cation-Exchange Membranes, and Nylon
Membranes: Humidity Influences, Environ. Sci. Technol., 49,
6102–6108, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Huang, J., Miller, M. B., Weiss-Penzias, P., and Gustin, M. S.: Comparison
of gaseous oxidized Hg measured by KCl-coated denuders, and nylon and cation
exchange membranes, Environ. Sci. Technol., 47, 7307–7316,
2013a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Huang, J. Y., Miller, M. B., Weiss-Penzias, P., and Gustin, M. S.:
Comparison of Gaseous Oxidized Hg Measured by KCl-Coated Denuders, and Nylon
and Cation Exchange Membranes, Environ. Sci. Technol., 47,
7307–7316, 2013b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Hynes, A. J., Donohoue, D. L., Goodsite, M. E., and Hedgecock, I. M.: Our
current understanding of major chemical and physical processes affecting
mercury dynamics in the atmosphere and at the air-water/terrestrial
interfaces, in: Mercury Fate and Transport in the Global Atmosphere, edited by: Mason,
R. and Pirrone, N., Springer, New York, NY, USA, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Jaffe, D. A., Lyman, S., Amos, H. M., Gustin, M. S., Huang, J. Y., Selin, N.
E., Levin, L., ter Schure, A., Mason, R. P., Talbot, R., Rutter, A., Finley,
B., Jaegle, L., Shah, V., McClure, C., Arnbrose, J., Gratz, L., Lindberg,
S., Weiss-Penzias, P., Sheu, G. R., Feddersen, D., Horvat, M., Dastoor, A.,
Hynes, A. J., Mao, H. T., Sonke, J. E., Slemr, F., Fisher, J. A., Ebinghaus,
R., Zhang, Y. X., and Edwards, G.: Progress on Understanding Atmospheric
Mercury Hampered by Uncertain Measurements, Environ. Sci. Technol., 48, 7204–7206, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Johnson, D. L. and Braman, R. S.: Distribution of atmospheric mercury
species near ground, Environ. Sci. Technol., 8, 1003–1009,
1974.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Laurier, F. J. G., Mason, R. P., Whalin, L., and Kato, S.: Reactive gaseous
mercury formation in the North Pacific Ocean's marine boundary layer: A
potential role of halogen chemistry, J. Geophys. Res.-Atmos., 108, 4529,
<a href="http://dx.doi.org/10.1029/2003JD003625" target="_blank">doi:10.1029/2003JD003625</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Lin, C. J., Pongprueksa, P., Lindberg, S. E., Pehkonen, S. O., Byun, D., and
Jang, C.: Scientific uncertainties in atmospheric mercury models I: Model
science evaluation, Atmos. Environ., 40, 2911–2928, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Lindberg, S., Bullock, R., Ebinghaus, R., Engstrom, D., Feng, X. B.,
Fitzgerald, W., Pirrone, N., Prestbo, E., and Seigneur, C.: A synthesis of
progress and uncertainties in attributing the sources of mercury in
deposition, Ambio, 36, 19–32, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
L'Vov, B. V.: Kinetics and mechanism of thermal decomposition of mercuric
oxide, Thermochim. Acta, 333, 21–26, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Lyman, S. N. and Gustin, M. S.: Speciation of atmospheric mercury at two
sites in northern Nevada, USA, Atmos. Environ., 42, 927–939, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Lyman, S. N. and Jaffe, D. A.: Formation and fate of oxidized mercury in the
upper troposphere and lower stratosphere, Nat. Geosci., 5, 114–117,
2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Lyman, S. N., Gustin, M. S., Prestbo, E. M., and Marsik, F. J.: Estimation
of Dry Deposition of Atmospheric Mercury in Nevada by Direct and Indirect
Methods, Environ. Sci. Technol., 41, 1970–1976, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Lyman, S. N., Gustin, M. S., Prestbo, E. M., Kilner, P. I., Edgerton, E.,
and Hartsell, B.: Testing and Application of Surrogate Surfaces for
Understanding Potential Gaseous Oxidized Mercury Dry Deposition,
Environ. Sci. Technol., 43, 6235–6241, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Lyman, S. N., Gustin, M. S., and Prestbo, E. M.: A passive sampler for
ambient gaseous oxidized mercury concentrations, Atmos. Environ.,
44, 246–252, 2010a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Lyman, S. N., Jaffe, D. A., and Gustin, M. S.: Release of mercury halides
from KCl denuders in the presence of ozone, Atmos. Chem. Phys., 10,
8197–8204, <a href="http://dx.doi.org/10.5194/acp-10-8197-2010" target="_blank">doi:10.5194/acp-10-8197-2010</a>, 2010b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Malcolm, E. G. and Keeler, G. J.: Evidence for a sampling artifact for
particulate-phase mercury in the marine atmosphere, Atmos. Environ., 41,
3352–3359, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
McClure, C. D., Jaffe, D. A., and Edgerton, E. S.: Evaluation of the KCl
denuder method for gaseous oxidized mercury using HgBr<sub>2</sub> at an in-service
AMNet site, Environ. Sci. Technol., 48, 11437–11444, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Obrist, D., Tas, E., Peleg, M., Matveev, V., Fain, X., Asaf, D., and Luria,
M.: Bromine-induced oxidation of mercury in the mid-latitude atmosphere, Nat.
Geosci., 4, 22–26, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib41"><label>41</label><mixed-citation>
Olson, E. S., Sharma, R. K., and Pavlish, J. H.: On the analysis of mercuric
nitrate in flue gas by GC-MS, Anal. Bioanal. Chem., 374, 1045–1049, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib42"><label>42</label><mixed-citation>
Pacyna, E. G., Pacyna, J. M., Steenhuisen, F., and Wilson, S.: Global
anthropogenic mercury emission inventory for 2000, Atmos. Environ., 40,
4048–4063, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib43"><label>43</label><mixed-citation>
Pal, B. and Ariya, P. A.: Gas-phase HO center dot-Initiated reactions of
elemental mercury: Kinetics, product studies, and atmospheric implications,
Environ. Sci. Technol., 38, 5555–5566, 2004a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib44"><label>44</label><mixed-citation>
Pal, B. and Ariya, P. A.: Studies of ozone initiated reactions of gaseous
mercury: kinetics, product studies, and atmospheric implications, Phys. Chem.
Chem. Phys., 6, 572–579, 2004b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib45"><label>45</label><mixed-citation>
Peleg, M., Tas, E., Matveev, V., Obrist, D., Moore, C. W., Gabay, M., and
Luria, M.: Observational evidence for involvement of nitrate radicals in
nighttime oxidation of mercury, Environ. Sci. Technol., 49, 14008–14018, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib46"><label>46</label><mixed-citation>
Peterson, S. H., Ackerman, J. T., and Costa, D. P.: Marine foraging ecology
influences mercury bioaccumulation in deep-diving northern elephant seals, P.
Roy. Soc, B-Biol. Sci., 282, 26085591, <a href="http://dx.doi.org/10.1098/rspb.2015.0710" target="_blank">doi:10.1098/rspb.2015.0710</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib47"><label>47</label><mixed-citation>
Rowe, M. D. and Perlinger, J. A.: Performance of a High Flow Rate, Thermally
Extractable Multicapillary Denuder for Atmospheric Semivolatile Organic
Compound Concentration Measurement, Environ. Sci. Technol., 44, 2098–2104,
2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib48"><label>48</label><mixed-citation>
Schroeder, W. H., Anlauf, K. G., Barrie, L. A., Lu, J. Y., Steffen, A.,
Schneeberger, D. R., and Berg, T.: Arctic springtime depletion of mercury,
Nature, 394, 331–332, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib49"><label>49</label><mixed-citation>
Seigneur, C., Wrobel, J., and Constantinou, E.: A chemical kinetic mechanism
for atmospheric inorganic mercury, Environ. Sci. Technol., 28, 1589–1597,
1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib50"><label>50</label><mixed-citation>
Seigneur, C., Vijayaraghavan, K., Lohman, K., Karamchandani, P., and Scott,
C.: Global source attribution for mercury deposition in the United States,
Environ. Sci. Technol., 38, 555–569, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib51"><label>51</label><mixed-citation>
Selin, N. E.: Global Biogeochemical Cycling of Mercury: A Review, Annu. Rev.
Env. Resour., 34, 43–63, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib52"><label>52</label><mixed-citation>
Shepler, B. C. and Peterson, K. A.: Mercury monoxide: A systematic
investigation of its ground electronic state, J. Phys. Chem. A, 107,
1783–1787, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib53"><label>53</label><mixed-citation>
Slemr, F., Ebinghaus, R., Brenninkmeijer, C. A. M., Hermann, M., Kock, H. H.,
Martinsson, B. G., Schuck, T., Sprung, D., van Velthoven, P., Zahn, A., and
Ziereis, H.: Gaseous mercury distribution in the upper troposphere and lower
stratosphere observed onboard the CARIBIC passenger aircraft, Atmos. Chem.
Phys., 9, 1957–1969, <a href="http://dx.doi.org/10.5194/acp-9-1957-2009" target="_blank">doi:10.5194/acp-9-1957-2009</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib54"><label>54</label><mixed-citation>
Sommar, J., Hallquist, M., Ljungstrom, E., and Lindqvist, O.: On the gas
phase reactions between volatile biogenic mercury species and the nitrate
radical, J. Atmos. Chem., 27, 233–247, 1997.
</mixed-citation></ref-html>
<ref-html id="bib1.bib55"><label>55</label><mixed-citation>
Sprovieri, F., Pirrone, N., Ebinghaus, R., Kock, H., and Dommergue, A.:
Corrigendum to “A review of worldwide atmospheric mercury measurements”
published in Atmos. Chem. Phys., 10, 8245–8265, 2010, Atmos. Chem. Phys., 10,
8531–8531, <a href="http://dx.doi.org/10.5194/acp-10-8531-2010" target="_blank">doi:10.5194/acp-10-8531-2010</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib56"><label>56</label><mixed-citation>
Steffen, A., Douglas, T., Amyot, M., Ariya, P., Aspmo, K., Berg, T.,
Bottenheim, J., Brooks, S., Cobbett, F., Dastoor, A., Dommergue, A.,
Ebinghaus, R., Ferrari, C., Gardfeldt, K., Goodsite, M. E., Lean, D.,
Poulain, A. J., Scherz, C., Skov, H., Sommar, J., and Temme, C.: A synthesis
of atmospheric mercury depletion event chemistry in the atmosphere and snow,
Atmos. Chem. Phys., 8, 1445–1482, <a href="http://dx.doi.org/10.5194/acp-8-1445-2008" target="_blank">doi:10.5194/acp-8-1445-2008</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib57"><label>57</label><mixed-citation>
Talbot, R., Mao, H., Scheuer, E., Dibb, J., and Avery, M.: Total depletion
of Hg degree in the upper troposphere-lower stratosphere, Geophys.
Res. Lett., 34, L23804, <a href="http://dx.doi.org/10.1029/2007GL031366" target="_blank">doi:10.1029/2007GL031366</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib58"><label>58</label><mixed-citation>
Tossell, J. A.: Calculation of the energetics for the oligomerization of gas
phase HgO and HgS and for the solvolysis of crystalline HgO and HgS, J. Phys. Chem. A, 110, 2571–2578, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib59"><label>59</label><mixed-citation>
Wang, F., Saiz-Lopez, A., Mahajan, A. S., Gómez Martín, J. C., Armstrong, D.,
Lemes, M., Hay, T., and Prados-Roman, C.: Enhanced production of oxidised
mercury over the tropical Pacific Ocean: a key missing oxidation pathway,
Atmos. Chem. Phys., 14, 1323–1335, <a href="http://dx.doi.org/10.5194/acp-14-1323-2014" target="_blank">doi:10.5194/acp-14-1323-2014</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib60"><label>60</label><mixed-citation>
Weiss-Penzias, P., Amos, H. M., Selin, N. E., Gustin, M. S., Jaffe, D. A.,
Obrist, D., Sheu, G.-R., and Giang, A.: Corrigendum to “Use of a global model
to understand speciated atmospheric mercury observations at five
high-elevation sites” published in Atmos. Chem. Phys., 15, 1161–1173, 2015,
Atmos. Chem. Phys., 15, 2225–2225, <a href="http://dx.doi.org/10.5194/acp-15-2225-2015" target="_blank">doi:10.5194/acp-15-2225-2015</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib61"><label>61</label><mixed-citation>
Widmer, N. C., West, J., and Cole, J. A.: Thermochemical study of mercury
oxidation, 93rd Annual Meeting of the Air and Waste Management Association, 18–22 June 2000, Salt Lake City, Utah, USA, 2000.
</mixed-citation></ref-html>
<ref-html id="bib1.bib62"><label>62</label><mixed-citation>
Wilcox, J. and Blowers, P.: Decomposition of Mercuric Chloride and
Application to Combustion Flue Gases, Environ. Chem., 1, 166–171,
2004.
</mixed-citation></ref-html>--></article>