<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" dtd-version="3.0">
  <front>
    <journal-meta>
<journal-id journal-id-type="publisher">AMT</journal-id>
<journal-title-group>
<journal-title>Atmospheric Measurement Techniques</journal-title>
<abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">1867-8548</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>

    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-9-859-2016</article-id><title-group><article-title>Aerosol effective density measurement using scanning mobility particle sizer
and quartz crystal microbalance with the <?xmltex \hack{\break}?>estimation of involved
uncertainty</article-title>
      </title-group><?xmltex \runningtitle{Aerosol effective density measurement}?><?xmltex \runningauthor{S.~G.~Aggarwal et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="no" rid="aff1 aff2">
          <name><surname>Sarangi</surname><given-names>Bighnaraj</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1 aff2">
          <name><surname>Aggarwal</surname><given-names>Shankar G.</given-names></name>
          <email>aggarwalsg@nplindia.org</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Sinha</surname><given-names>Deepak</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Gupta</surname><given-names>Prabhat K.</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Academy of Scientific and Innovative Research (AcSIR),
CSIR-National Physical Laboratory Campus, <?xmltex \hack{\break}?>New Delhi, 110012,
India</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Analytical Chemistry Section, CSIR-National Physical
Laboratory, New Delhi 110012, India</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Government Nagarjun Post
Graduate Science College, Raipur 492010, India</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Shankar G. Aggarwal (aggarwalsg@nplindia.org)</corresp></author-notes><pub-date><day>4</day><month>March</month><year>2016</year></pub-date>
      
      <volume>9</volume>
      <issue>3</issue>
      <fpage>859</fpage><lpage>875</lpage>
      <history>
        <date date-type="received"><day>2</day><month>October</month><year>2015</year></date>
           <date date-type="rev-request"><day>8</day><month>December</month><year>2015</year></date>
           <date date-type="rev-recd"><day>11</day><month>February</month><year>2016</year></date>
           <date date-type="accepted"><day>15</day><month>February</month><year>2016</year></date>
      </history>
      <permissions>
<license license-type="open-access">
<license-p>This work is licensed under a Creative Commons Attribution 3.0 Unported License. To view a copy of this license, visit <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/3.0/">http://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions><self-uri xlink:href="https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016.html">This article is available from https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016.html</self-uri>
<self-uri xlink:href="https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016.pdf</self-uri>


      <abstract>
    <p>In this work, we have used a scanning mobility particle sizer (SMPS) and a
quartz crystal microbalance (QCM) to estimate the effective density of
aerosol particles. This approach is tested for aerosolized particles
generated from the solution of standard materials of known density, i.e.
ammonium sulfate (AS), ammonium nitrate (AN) and sodium chloride (SC), and
also applied for ambient measurement in New Delhi. We also discuss
uncertainty involved in the measurement. In this method, dried particles are
introduced in to a differential mobility analyser (DMA), where size
segregation is done based on particle electrical mobility. Downstream of the  DMA, the aerosol stream is subdivided into two parts. One is
sent to a condensation particle counter (CPC) to measure particle number
concentration, whereas  the other one is sent to  the QCM to measure the particle mass
concentration simultaneously. Based on particle volume derived from size
distribution data of  the SMPS and mass concentration data obtained from  the QCM, the
mean effective density (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> with uncertainty of inorganic salt
particles (for particle count mean diameter (CMD) over a size range 10–478 nm),
i.e. AS, SC and AN, is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.76</mml:mn><mml:mo>±</mml:mo><mml:mn>0.24</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>2.08</mml:mn><mml:mo>±</mml:mo><mml:mn>0.19</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.69</mml:mn><mml:mo>±</mml:mo><mml:mn>0.28</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, values which are comparable with
the material density (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> values, 1.77, 2.17 and 1.72 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>,
respectively. Using this technique, the percentage contribution of error in
the measurement of effective density is calculated to be in the range of 9–17 %.
Among  the individual uncertainty components, repeatability of
particle mass obtained by  the QCM,  the QCM crystal frequency, CPC counting
efficiency, and  the equivalence of CPC- and QCM-derived volume are the major
contributors to the expanded uncertainty (at <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) in comparison to other
components, e.g. diffusion correction, charge correction, etc. Effective
density for ambient particles at the beginning of the  winter period in New Delhi
was measured to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.28</mml:mn><mml:mo>±</mml:mo><mml:mn>0.12</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. It was found that in
general, mid-day effective density of ambient aerosols increases with
increase in CMD of particle size measurement but particle photochemistry is
an important factor to govern this trend. It is further observed that the
CMD has good correlation with O<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>, SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> and ambient RH, suggesting
that possibly sulfate secondary materials have a substantial contribution in
particle effective density. This approach can be useful for real-time
measurement of effective density of both laboratory-generated and ambient
aerosol particles, which is very important for studying the physico-chemical
properties of particles.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p>The density of atmospheric particles is an important parameter for prediction of
particle physical, micro-physical and optical properties (Tang and
Munkelwitz, 1994; Baron and Willeke, 2001). It is not only governed by the
shape, morphology and mixing state of  the particles, but also linked with the
chemical composition of particles. The density, combined with the dynamic
shape factor (DSF, which is a measure of non-sphericity, <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">χ</mml:mi></mml:math></inline-formula>),
relates the aerodynamic diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of a particle to its electrical
mobility diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> through its mass equivalent diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>M</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (Kelly
and McMurry, 1992) by
          <disp-formula id="Ch1.E1" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msubsup><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mi>C</mml:mi><mml:mfenced close=")" open="("><mml:msub><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext></mml:msub></mml:mfenced><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msubsup><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mi>C</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub><mml:mo>)</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msup><mml:mfenced open="[" close="]"><mml:mi>C</mml:mi><mml:mfenced open="(" close=")"><mml:msub><mml:mi>d</mml:mi><mml:mtext>M</mml:mtext></mml:msub></mml:mfenced></mml:mfenced><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:mo>×</mml:mo><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msup><mml:mfenced open="[" close="]"><mml:mi>C</mml:mi><mml:mfenced open="(" close=")"><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub></mml:mfenced></mml:mfenced><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:mo>×</mml:mo><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
        where <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>C</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>C</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>C</mml:mi><mml:mo>(</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mtext>M</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are the Cunningham slip correction factor for
corresponding diameters (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>M</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is the
standard density (1 g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the particle density.
As given in  Eq. (1),   combined measurement of mobility and aerodynamic
diameters yields  the density of particles having any shape. For non-spherical
and porous particles, the tendency has been to define an effective density
instead (Hand and Kreidenweis, 2002; Jimenez et al., 2003). Effective
density reflects both particle density and shape information:
          <disp-formula id="Ch1.E2" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow><mml:mi mathvariant="italic">χ</mml:mi></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>This equation suggests that if the particles are spherical with the absence
of internal voids (i.e. <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">χ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>), then the effective density is equal to
the material density. If particles are non-spherical, then the calculated
volume or volume concentration surpasses the true value, and the effective
density is less than the material density. However, in general effective
density is measured assuming that particles are spherical. Therefore the
detailed uncertainty budget estimation in particle effective density
measurement is very important to better simulate the results of particle
properties, which are linked with such measurements.</p>
      <p>As a result of aerosol instrumentation advancement in recent decades,
several approaches for the real-time measurements of particle effective
density have been developed. Hand and Kreidenweis (2002) measured particle
optical size (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>o</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, using an optical particle counter
(OPC), a differential
mobility analyser (DMA), and an aerodynamic particle sizer (APS), respectively and aligned
these sizes in the instrument overlap regions, which allowed them to
retrieve particle effective density. Pioneering work was done by McMurry et al. (2002)
in which they determined the density of aerosol particles by
selecting particles of known mobility diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> using a DMA and subsequently measuring their mass (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mtext>p</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and
number concentration using aerosol particle mass analyser (APM) and
condensation particle counter (CPC), respectively. Since then, several
instrumental approaches have been reported following the measurements of
particle mass and mobility-equivalent volume (<inline-formula><mml:math display="inline"><mml:mi>V</mml:mi></mml:math></inline-formula>) to determine effective
density:
          <disp-formula id="Ch1.E3" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">eff</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>Khlystov et al. (2004) reported a simple algorithm that was developed to
combine aerosol size distributions measured using scanning mobility particle
sizer (SMPS) and an APS. Then this integrated SMPS–APS volume concentration
and PM<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn>2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentration measured using a tapered element
oscillating microbalance (TEOM) were used to calculate effective density.
Katrib et al. (2005) used a SMPS in parallel with an aerosol mass
spectrometer (AMS) to measure particle <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, vacuum diameter
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>va</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> to measure effective density. Similarly,
Kostenidou et al. (2007) developed an algorithm for the calculation of
organic aerosol density in mixed organic–inorganic particles combining the
measurements by SMPS and AMS. Kannosto et al. (2008) investigated the
mode-resolved density of ultrafine particles measured in boreal forest using
an electrical low-pressure impactor (ELPI) for particle mass distribution and
SMPS or differential mobility particle sizer (DMPS) operated in parallel for
size distribution data. Virtanen et al. (2002) and Maricq and Xu (2004)
adopted a similar technique (ELPI–SMPS) for measurement of the density of
diesel exhaust soot particles. Spencer et al. (2007) reported the
simultaneous measurements of the effective density and chemical composition
of individual ambient particles in Riverside, California by coupling a DMA
with an ultrafine aerosol time-of-flight mass spectrometer (UF-ATOFMS).</p>
      <p>Olfert et al. (2007) measured the effective density and fractal dimension of
particles emitted from a light-duty diesel vehicle fitted with a diesel
oxidation catalyst (DOC) using a DMA and Couette centrifugal particle mass
analyser (Couette CPMA). Recently Quiros et al. (2015) also used a DMA–CPMA
technique to measure the effective density of particles emitted from five
light-duty vehicles. Ovigneur et al. (2011) presented an approach to
retrieve stratospheric aerosol densities in the altitude range 10–40 km from
SCIAMACHY limb radiance measurements in the spectral range of the O<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>A
absorption band, near 760 nm.</p>
      <p>Similarly, more recently a DMA–APM approach to get particle size and mass
information, respectively has been extensively applied for particle density
measurements in different environments (Geller et al., 2006; Malloy et al.,
2009; Lee et al., 2009; Gysel et al., 2011; Nakao et al., 2013; Rissler et
al., 2014; Yin et al., 2015).</p>
      <p>Although these various instrumental approaches have been applied
successfully to different aerosol types for their effective density
measurements, very limited information is available on the uncertainty
(standard) involved with the data reported. These data suggest that the
uncertainty in the measurement of effective density may vary widely from 3
to 30 % (McMurry et al., 2002; Hand and Kreidenweis, 2002; Olfert et al.,
2007; Johnson et al., 2014). More importantly, to our best knowledge no
report is available on the detailed combined uncertainty budget in such
measurements.</p>
      <p>In this work, we have developed a simplified approach to determine aerosol
effective density by measuring particle size distribution using a SMPS
(electrostatic classifier (EC) <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> DMA <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> CPC) and simultaneously
measuring particle mass using the quartz crystal microbalance (QCM)
technique. This approach is demonstrated here with laboratory-generated
particles of inorganic salt materials whose density is known to estimate the
combined uncertainty in the measurement. The setup is then applied for
effective density measurement of ambient aerosols in New Delhi for a week.
Here we also discuss the variation of effective density of particles with the
meteorological parameters and atmospheric gaseous species, and their
influences on effective density of ambient aerosols.</p>
</sec>
<sec id="Ch1.S2">
  <title>Method</title>
      <p>We used a SMPS (TSI 3080) with a QCM (PC-2, California Measurements, Inc.), which is a
10-stage cascade impactor with  cutoff sizes (aerodynamic diameters)
from upper to lower stages of 25, 12.5, 6.4, 3.2, 1.6, 0.8, 0.4, 0.2, 0.1
and 0.05 <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>m.</p>
<sec id="Ch1.S2.SS1">
  <title>Scanning mobility particle sizer </title>
      <p>The SMPS consists of an electrostatic classifier (EC, TSI 3080, including an
impactor (0.0457 cm, TSI 1 502 296) and Kr-85 bipolar charger (TSI 3077),
differential mobility analyser (DMA, TSI 3081) and condensation particle
counter (CPC, TSI 3788). Different nozzle sizes for different sample flow
rates are used in the SMPS, e.g. for flow rate 0.2–0.8 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>,
0.0457 cm a nozzle size of the impactor is recommended. We use a sample flow
rate 0.48 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> in all the measurements, the cut-off size (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mn>50</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>)
of the impactor at this flow rate is 472 nm. The aerosol stream enters
through the inlet impactor and the resulting particles get neutralized
through the bipolar charger (in accordance with
the Fuchs equilibrium charge distribution principle). Then this neutral
aerosol stream enters to the DMA, where a varying voltage is applied to the
DMA rod so that according to the electrical mobility of particles,
respective sized particles exit through the slit at the bottom of the DMA.
These size-segregated particles then enter  the  CPC, where particles undergo
condensational growth while passing through saturated liquid vapours followed
by their detection through optics. Before the density measurement,  the DMA was
calibrated with 60 and 100 nm polystyrene latex (PSL) particles (Sarangi et
al., 2014). Also the calibration of CPC counts was checked by a gravimetric
approach (Aggarwal et al., 2013).</p>
</sec>
<sec id="Ch1.S2.SS2">
  <title>Quartz crystal microbalance</title>
      <p>The QCM uses piezoelectric quartz crystal substrates for the collection of
particles which enter through an impactor nozzle placed before every stage.
Every stage consists of two quartz crystals: one of the crystals, the
sensing oscillating crystal is placed close to the nozzle-exit, and it
collects particles; the other crystal, the reference crystal, does not
collect particles but is there to nullify background frequency, temperature
and other effects on both the crystals. The two crystals are identical and
have a resonant frequency of 10 MHz. As the particles impact on the sensing
crystal, its frequency decreases while the reference crystal frequency
remains unchanged. The difference in frequency of the mixer output (which is
generally the same amount of decrease as in the sensing crystal frequency) is
considered as  the change in the frequency. The amount of frequency change of the
signal output is directly proportional to the particle mass deposited on the
sensing crystal. The QCM uses the following information to determine particle
concentration: the initial frequency before particle collection, the
frequency after particle collection (the final frequency), and the sampling
time. The QCM design was verified and calibrated at Los Alamos National
Laboratory and the Aerosol Laboratory, ULCA.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><caption><p>Measurement setup of effective density measurement of laboratory-generated particles and ambient aerosols.</p></caption>
          <?xmltex \igopts{width=426.791339pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016-f01.jpg"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS3">
  <title>Experimental setup</title>
      <p>The experimental setup used in this study is shown in Fig. 1. For validation
of the method, standard materials (inorganic salts) of known density were
used. Solution of a standard material was aerosolized by an atomizer (TSI
3076) using 5N purity N<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> gas, and  the generated aerosol stream was passed
through two diffusion dryers placed in series. This dried aerosol stream (RH
&lt; 5 %) was then introduced to  the SMPS (through the inlet impactor).
Downstream of  the DMA,  the aerosol flow was subdivided into two parts. One
was connected to  the CPC and other one to  the QCM, which were placed at equal
distances from  the DMA (the tube length between DMA exit and inlet of CPC or
QCM was 25 cm). The sample flow rate of  the SMPS was set to 0.48 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, which
is a sum of flow rates of  the CPC and  the QCM, i.e. 0.24 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> each. The
purpose of selecting 0.24 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for the CPC is to keep its flow rate
equal to the flow rate of  the QCM (which works only at 0.24 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for better
size segregation). Sheath flow rate of  the SMPS was set to 4.8 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>.
Particles of size range 10–478 nm were segregated by  the DMA and number
concentration was measured by  the CPC. Simultaneously, the corresponding mass
distribution was obtained from  the QCM. For the calculation of effective
density, we used count mean diameter (CMD) derived from the size
distribution scan over a size range 10–478 nm of the  CPC and the real-time
corresponding mass concentration obtained from  the QCM downstream of the  DMA. In
this approach, we assumed that particles are spherical (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">χ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>,
Eq. 1), thus  the electrical mobility diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, related to DMA size
segregation) is equivalent to  the aerodynamic diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:math></inline-formula> related to QCM
size segregation, based on impaction theory). It is important to note,
however, that uncertainty due to this assumption is added to the combined
uncertainty estimation (see Sect. 3.2.2).</p>
      <p>Based on the particle size distribution obtained from  the SMPS and corresponding
mass concentration measured from  the QCM, we calculated  the effective density of
particles using Eq. (3):
            <disp-formula id="Ch1.E4" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">eff</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>m</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>×</mml:mo><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:mo>×</mml:mo><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mtext>p</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the total mass concentration of the particles measured
by  the QCM  downstream of the DMA. The <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>m</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are the
mobility diameter of particles and their corresponding number concentration
in size bin <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, respectively.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <title>Inorganic salts used</title>
      <p>To validate the measurement of particle effective density using  the proposed
setup, standard materials of known density were used. These materials were
used to prepare solutions (0.001 % <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>w</mml:mi><mml:mo>/</mml:mo><mml:mi>v</mml:mi></mml:mrow></mml:math></inline-formula>) using Milli-Q water
(&gt; 18 M<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">Ω</mml:mi></mml:math></inline-formula> cm). This solution was nebulized (at 0.7 bar
pressure) to generate particles. The details of the material used are
summarized in Table 1.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><caption><p>Inorganic salts used for the measurement of density using  the SMPS–QCM
approach.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:colspec colnum="7" colname="col7" align="left"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Inorganic salt</oasis:entry>  
         <oasis:entry colname="col2">Molecular formula</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">g</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">mol</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ρ</mml:mi></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">g</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col5">Maximum number</oasis:entry>  
         <oasis:entry colname="col6">Supplier</oasis:entry>  
         <oasis:entry colname="col7">Purity</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5">of ions</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">Ammonium sulfate</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">132.1</oasis:entry>  
         <oasis:entry colname="col4">1.77</oasis:entry>  
         <oasis:entry colname="col5">3</oasis:entry>  
         <oasis:entry colname="col6">MERCK</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn>99.5</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Sodium chloride</oasis:entry>  
         <oasis:entry colname="col2">NaCl</oasis:entry>  
         <oasis:entry colname="col3">80.1</oasis:entry>  
         <oasis:entry colname="col4">2.17</oasis:entry>  
         <oasis:entry colname="col5">2</oasis:entry>  
         <oasis:entry colname="col6">Sigma Aldrich</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn>99.5</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Ammonium nitrate</oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">58.4</oasis:entry>  
         <oasis:entry colname="col4">1.72</oasis:entry>  
         <oasis:entry colname="col5">2</oasis:entry>  
         <oasis:entry colname="col6">MERCK</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mrow><mml:mo>&gt;</mml:mo><mml:mn>99.5</mml:mn></mml:mrow></mml:math></inline-formula> %</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S2.SS5">
  <title>Estimation of uncertainty in effective density measurement</title>
      <p>The uncertainty due to different components  belonging to particle mass
measurement by QCM and volume measurement by CPC are taken into
consideration in the measurement of effective density of laboratory-generated aerosol particles (AS, SC and AN), Fig. 2. The combined standard
uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mtext>c</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> can be defined as

                <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E5"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mtext>c</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msup><mml:mfenced open="(" close=")"><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E6"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mtext>e</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mi>k</mml:mi><mml:mo>×</mml:mo><mml:msub><mml:mi>u</mml:mi><mml:mtext>c</mml:mtext></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the standard uncertainty of the component <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mtext>e</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is
the expanded uncertainty at <inline-formula><mml:math display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> (coverage factor). In this study, <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> at
95 % confidence level. Details of the estimation of uncertainty are
discussed in the following sections.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p>Cause-effective diagram of the uncertainty components considered in
this study, constituting the entire uncertainty budget in the measurement of
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> using the SMPS–QCM approach.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016-f02.jpg"/>

        </fig>

</sec>
<sec id="Ch1.S2.SS6">
  <title>Effective density measurement of ambient aerosols</title>
      <p>The experimental setup used to measure effective density of ambient aerosols
using the  proposed approach is shown in Fig. 1. The measurement was performed
for urban aerosols in New Delhi at  the National Physical Laboratory (NPL) for  the
week of 12–18 November 2014. The measurement site is known to be a good
representative site of urban aerosols in Delhi with the combined influence
of residential, agricultural, traffic and industrial emissions (Sarangi et
al., 2015). Also, meteorological data during mid-November in Delhi is
known to be representative of the year-round average data. Aerosol samples
were aspirated at the rooftop of the laboratory (<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn>15</mml:mn></mml:mrow></mml:math></inline-formula> m above
the ground) through a cyclone inlet (2.5 <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>m cutoff size) connected
with copper tubing of internal diameter 6 mm and length <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula> m.
Then aerosols were dried after passing through two diffusion dryers before
they reached  the inlet impactor of  the SMPS.</p>
</sec>
<sec id="Ch1.S2.SS7">
  <title>Meteorological data</title>
      <p>Hourly meteorological data (temperature, relative humidity, wind speed and
direction) and concentration of atmospheric gases, i.e. sulfur dioxide
(SO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, carbon monoxide (CO), ozone (O<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and nitrogen oxides
(NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> for the study period are obtained from a continuous ambient air
quality monitoring station (CAQMS) of the Central Pollution Control Board
(CPCB), Shadipur located within 3 km radius from the measurement site
(<uri>http://www.cpcb.gov.in/CAAQM/mapPage/frmindiamap.aspx</uri>).<?xmltex \hack{\newpage}?></p>
</sec>
</sec>
<sec id="Ch1.S3">
  <title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <title>Laboratory test</title>
      <p>Laboratory tests of effective density measurement using the proposed SMPS–QCM
setup were performed with three different inorganic salts: ammonium
sulfate (AS), sodium chloride (SC) and ammonium nitrate (AN). Before the
density measurement of inorganic salt materials,  the DMA was calibrated using
particle size standards (PSL 60 and 100 nm), which are traceable to SI
through  the National Institute of Standards and Technology (NIST), USA. Counting
efficiency of the  CPC was checked using a filter-based gravimetric approach, which
is discussed elsewhere (Aggarwal et al., 2013). Crystals of all the stages
of  the QCM were tested for background frequency prior to measurements. As per
the QCM instrumental guidelines, background frequency of the crystals of all
the stages was set to between 2 and 4 kHz for a valid measurement.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2" specific-use="star"><caption><p>Measured effective density of laboratory-generated inorganic salt
particles.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="center"/>
     <oasis:colspec colnum="3" colname="col3" align="center"/>
     <oasis:colspec colnum="4" colname="col4" align="center"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="center"/>
     <oasis:colspec colnum="7" colname="col7" align="center"/>
     <oasis:colspec colnum="8" colname="col8" align="center"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Inorganic</oasis:entry>  
         <oasis:entry colname="col2">Density (<inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ρ</mml:mi></mml:math></inline-formula>) from</oasis:entry>  
         <oasis:entry namest="col3" nameend="col6">Effective density (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> SD measured </oasis:entry>  
         <oasis:entry colname="col7">Mean CMD <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula> SD</oasis:entry>  
         <oasis:entry colname="col8">Mean number</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">salts</oasis:entry>  
         <oasis:entry colname="col2">literature (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">g</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry rowsep="1" namest="col3" nameend="col6">using the SMPS–QCM approach (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">g</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) </oasis:entry>  
         <oasis:entry colname="col7">(nm)</oasis:entry>  
         <oasis:entry colname="col8">concentration</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">Mean</oasis:entry>  
         <oasis:entry colname="col4">Max</oasis:entry>  
         <oasis:entry colname="col5">Min</oasis:entry>  
         <oasis:entry colname="col6">% SD</oasis:entry>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8">(<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mn mathvariant="normal">5</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> particles cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">1.77</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.76</mml:mn><mml:mo>±</mml:mo><mml:mn>0.04</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">1.86</oasis:entry>  
         <oasis:entry colname="col5">1.66</oasis:entry>  
         <oasis:entry colname="col6">2.27</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mrow><mml:mn>33.17</mml:mn><mml:mo>±</mml:mo><mml:mn>0.43</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col8">4.6</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">NaCl</oasis:entry>  
         <oasis:entry colname="col2">2.17</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mrow><mml:mn>2.08</mml:mn><mml:mo>±</mml:mo><mml:mn>0.12</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">2.19</oasis:entry>  
         <oasis:entry colname="col5">1.91</oasis:entry>  
         <oasis:entry colname="col6">5.76</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mrow><mml:mn>33.17</mml:mn><mml:mo>±</mml:mo><mml:mn>0.21</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col8">8.3</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">NH</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">NO</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">1.72</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.69</mml:mn><mml:mo>±</mml:mo><mml:mn>0.17</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col4">1.92</oasis:entry>  
         <oasis:entry colname="col5">1.51</oasis:entry>  
         <oasis:entry colname="col6">10.1</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mrow><mml:mn>31.20</mml:mn><mml:mo>±</mml:mo><mml:mn>0.33</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col8">2.3</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><caption><p>Laboratory-generated inorganic salt particle effective density
versus count mean diameter over the size range 10–478 nm:
<bold>(a)</bold> ammonium sulfate, <bold>(b)</bold> sodium chloride and
<bold>(c)</bold> ammonium nitrate.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016-f03.jpg"/>

        </fig>

      <p>Effective density is estimated from  the SMPS-derived volume and QCM-measured mass
using Eq. (4). Figure 3 shows the effective density (g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> versus
count mean diameter (CMD) for AS, SC and AN particles. The mean effective particle
densities  with  standard deviation were determined to be
<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.76</mml:mn><mml:mo>±</mml:mo><mml:mn>0.04</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>2.08</mml:mn><mml:mo>±</mml:mo><mml:mn>0.12</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.69</mml:mn><mml:mo>±</mml:mo><mml:mn>0.17</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for AS, SC
and AN particles, respectively. Number concentration and detailed
statistics are shown in Table 2. The results indicate that the measured
effective density of laboratory-generated inorganic salt particles using the
SMPS–QCM approach agrees well with the reported value in the literature
(Svenningsson et al., 2006; Schmid et al., 2009; Schkolnik et al., 2007).</p>
</sec>
<sec id="Ch1.S3.SS2">
  <title>Detailed uncertainty calculations</title>
      <p>Because the measurement of particle effective density using the SMPS–QCM
approach (Eq. 4) is based on (i) particle mass measurement using the QCM and
(ii) particle volume measurement using DMA <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> CPC, therefore the
uncertainty in density measurement involves the components which comprise
these two measurements. These components are shown in the cause-effective
diagram in Fig. 2.</p>
      <p>The uncertainties due to different parameters involved during the
measurement of effective density are estimated for laboratory-generated
aerosol particles (of AS, SC and AN). The combined standard uncertainty for
the measurement of effective density <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> can be
expressed as
            <disp-formula id="Ch1.E7" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle></mml:math></inline-formula> represent the combined relative standard
uncertainty in density, mass and volume of the particles, respectively.
Using Eq. (7) the combined standard uncertainty in the measurement of
effective density of AS, SC and AN was estimated to be 0.24, 0.19 and 0.28 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>.
The detailed uncertainty budget for the estimation of uncertainty
in measurement of <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mi mathvariant="normal">eff</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of all the inorganic salts species considered in this study (i.e. AS, SC and AN) is shown in Table 3. In what follows we discuss the individual combined relative standard
uncertainty for both mass and volume for ammonium sulfate particles as an
example.</p>
<sec id="Ch1.S3.SS2.SSS1">
  <title>Uncertainty in particle mass measurement using QCM</title>
      <p>The mass concentration of monodisperse inorganic salt particles (downstream of  the DMA) is obtained by QCM. The QCM uses the following information to
determine particle concentration: (i) the initial frequency before particle
collection, (ii) the frequency after particle collection (the final
frequency) and (iii) the sampling time. Once these are available, the
instrument finds the frequency change (<inline-formula><mml:math display="inline"><mml:mrow><mml:mtext>d</mml:mtext><mml:mi>F</mml:mi></mml:mrow></mml:math></inline-formula> in Hz), divides it by the sampling
time (d<inline-formula><mml:math display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula> in min) and multiplies it by a mass sensitivity constant (<inline-formula><mml:math display="inline"><mml:mi>K</mml:mi></mml:math></inline-formula> in
<inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g min (Hz m<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) of an impactor stage, and then finally gives the
result of particle mass concentration (<inline-formula><mml:math display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> in <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>:
              <disp-formula id="Ch1.E8" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:mi>K</mml:mi><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mtext>d</mml:mtext><mml:mi>F</mml:mi></mml:mrow><mml:mrow><mml:mtext>d</mml:mtext><mml:mi>T</mml:mi></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>Equation (8) represents the mass concentration, which is a function of
change in frequency of quartz crystal and the sampling time, and mass
sensitivity constant. Therefore,  the uncertainty involved in particle mass
measurement has significant contributions from these parameters which are
discussed in detail in  the following sections.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><caption><p>The uncertainty budget in the measurement of effective density of
laboratory-generated inorganic salt particles (ammonium sulfate, AS; sodium
chloride, SC;  ammonium nitrate, AN).</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{0.95}[0.95]?><oasis:tgroup cols="12">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:colspec colnum="7" colname="col7" align="left"/>
     <oasis:colspec colnum="8" colname="col8" align="left"/>
     <oasis:colspec colnum="9" colname="col9" align="left"/>
     <oasis:colspec colnum="10" colname="col10" align="left"/>
     <oasis:colspec colnum="11" colname="col11" align="left"/>
     <oasis:colspec colnum="12" colname="col12" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">  
         <oasis:entry namest="col1" nameend="col12" align="center">Mass measurement by quartz crystal microbalance (QCM) </oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>  
         <oasis:entry namest="col10" nameend="col12">Contribution of relative standard </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Source of</oasis:entry>  
         <oasis:entry colname="col2">Uncertainty</oasis:entry>  
         <oasis:entry namest="col3" nameend="col5" align="center">Standard uncertainty, </oasis:entry>  
         <oasis:entry colname="col6">Distribution</oasis:entry>  
         <oasis:entry namest="col7" nameend="col9" align="center">Relative standard, </oasis:entry>  
         <oasis:entry namest="col10" nameend="col12">uncertainty in the combined </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">uncertainty</oasis:entry>  
         <oasis:entry colname="col2">type</oasis:entry>  
         <oasis:entry namest="col3" nameend="col5" align="center"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">g</mml:mi></mml:mrow></mml:math></inline-formula>) </oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry namest="col7" nameend="col9" align="center">uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:mfenced close=")" open="("><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry namest="col10" nameend="col12">relative uncertainty of density </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry rowsep="1" colname="col3"/>  
         <oasis:entry rowsep="1" colname="col4"/>  
         <oasis:entry rowsep="1" colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry rowsep="1" colname="col7"/>  
         <oasis:entry rowsep="1" colname="col8"/>  
         <oasis:entry rowsep="1" colname="col9"/>  
         <oasis:entry rowsep="1" namest="col10" nameend="col12">measurement, <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msup><mml:mfenced open="(" close=")"><mml:mfrac><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:msup><mml:mfenced open="(" close=")"><mml:mfrac><mml:mrow><mml:mi>u</mml:mi><mml:mfenced open="(" close=")"><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfenced></mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfrac></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula> (%) </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">AS</oasis:entry>  
         <oasis:entry colname="col4">SC</oasis:entry>  
         <oasis:entry colname="col5">AN</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">AS</oasis:entry>  
         <oasis:entry colname="col8">SC</oasis:entry>  
         <oasis:entry colname="col9">AN</oasis:entry>  
         <oasis:entry colname="col10">AS</oasis:entry>  
         <oasis:entry colname="col11">SC</oasis:entry>  
         <oasis:entry colname="col12">AN</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">1.45</oasis:entry>  
         <oasis:entry colname="col4">0.05</oasis:entry>  
         <oasis:entry colname="col5">0.18</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.053</oasis:entry>  
         <oasis:entry colname="col8">0.004</oasis:entry>  
         <oasis:entry colname="col9">0.067</oasis:entry>  
         <oasis:entry colname="col10">15.1</oasis:entry>  
         <oasis:entry colname="col11">0.17</oasis:entry>  
         <oasis:entry colname="col12">16.2</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">0.54</oasis:entry>  
         <oasis:entry colname="col4">0.27</oasis:entry>  
         <oasis:entry colname="col5">0.05</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.019</oasis:entry>  
         <oasis:entry colname="col8">0.019</oasis:entry>  
         <oasis:entry colname="col9">0.011</oasis:entry>  
         <oasis:entry colname="col10">2.14</oasis:entry>  
         <oasis:entry colname="col11">4.81</oasis:entry>  
         <oasis:entry colname="col12">1.42</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">1.01</oasis:entry>  
         <oasis:entry colname="col4">0.49</oasis:entry>  
         <oasis:entry colname="col5">0.09</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.037</oasis:entry>  
         <oasis:entry colname="col8">0.036</oasis:entry>  
         <oasis:entry colname="col9">0.037</oasis:entry>  
         <oasis:entry colname="col10">7.32</oasis:entry>  
         <oasis:entry colname="col11">16.5</oasis:entry>  
         <oasis:entry colname="col12">4.87</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type B</oasis:entry>  
         <oasis:entry colname="col3">0.59</oasis:entry>  
         <oasis:entry colname="col4">0.29</oasis:entry>  
         <oasis:entry colname="col5">0.06</oasis:entry>  
         <oasis:entry colname="col6">Rectangular</oasis:entry>  
         <oasis:entry colname="col7">0.022</oasis:entry>  
         <oasis:entry colname="col8">0.021</oasis:entry>  
         <oasis:entry colname="col9">0.022</oasis:entry>  
         <oasis:entry colname="col10">2.51</oasis:entry>  
         <oasis:entry colname="col11">5.64</oasis:entry>  
         <oasis:entry colname="col12">1.72</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1">Sampling time</oasis:entry>  
         <oasis:entry namest="col2" nameend="col12" align="center">Negligible </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry namest="col1" nameend="col12" align="center">Volume measurement by scanning mobility particle sizer (SMPS) </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>  
         <oasis:entry namest="col10" nameend="col12">Contribution of relative standard </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Source of</oasis:entry>  
         <oasis:entry colname="col2">Uncertainty</oasis:entry>  
         <oasis:entry namest="col3" nameend="col5" align="center">Standard uncertainty, </oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry namest="col7" nameend="col9" align="center">Relative standard  </oasis:entry>  
         <oasis:entry namest="col10" nameend="col12">uncertainty in the combined </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">uncertainty</oasis:entry>  
         <oasis:entry colname="col2">type</oasis:entry>  
         <oasis:entry namest="col3" nameend="col5" align="center">(<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula>) </oasis:entry>  
         <oasis:entry colname="col6">Distribution</oasis:entry>  
         <oasis:entry namest="col7" nameend="col9" align="center">uncertainty, <inline-formula><mml:math display="inline"><mml:mrow><mml:mfenced close=")" open="("><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry namest="col10" nameend="col12">relative uncertainty of density </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry rowsep="1" colname="col3"/>  
         <oasis:entry rowsep="1" colname="col4"/>  
         <oasis:entry rowsep="1" colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry rowsep="1" colname="col7"/>  
         <oasis:entry rowsep="1" colname="col8"/>  
         <oasis:entry rowsep="1" colname="col9"/>  
         <oasis:entry rowsep="1" namest="col10" nameend="col12">measurement, <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msup><mml:mfenced close=")" open="("><mml:mfrac><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:msup><mml:mfenced close=")" open="("><mml:mfrac><mml:mrow><mml:mi>u</mml:mi><mml:mfenced close=")" open="("><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfenced></mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfrac></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:math></inline-formula> (%) </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">AS</oasis:entry>  
         <oasis:entry colname="col4">SC</oasis:entry>  
         <oasis:entry colname="col5">AN</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7">AS</oasis:entry>  
         <oasis:entry colname="col8">SC</oasis:entry>  
         <oasis:entry colname="col9">AN</oasis:entry>  
         <oasis:entry colname="col10">AS</oasis:entry>  
         <oasis:entry colname="col11">SC</oasis:entry>  
         <oasis:entry colname="col12">AN</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">2.13</oasis:entry>  
         <oasis:entry colname="col4">1.63</oasis:entry>  
         <oasis:entry colname="col5">2.28</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.011</oasis:entry>  
         <oasis:entry colname="col8">0.008</oasis:entry>  
         <oasis:entry colname="col9">0.014</oasis:entry>  
         <oasis:entry colname="col10">0.67</oasis:entry>  
         <oasis:entry colname="col11">0.89</oasis:entry>  
         <oasis:entry colname="col12">0.74</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">2.12</oasis:entry>  
         <oasis:entry colname="col4">1.63</oasis:entry>  
         <oasis:entry colname="col5">2.28</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.011</oasis:entry>  
         <oasis:entry colname="col8">0.005</oasis:entry>  
         <oasis:entry colname="col9">0.014</oasis:entry>  
         <oasis:entry colname="col10">0.67</oasis:entry>  
         <oasis:entry colname="col11">0.89</oasis:entry>  
         <oasis:entry colname="col12">0.74</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type B</oasis:entry>  
         <oasis:entry colname="col3">1.62</oasis:entry>  
         <oasis:entry colname="col4">1.62</oasis:entry>  
         <oasis:entry colname="col5">1.35</oasis:entry>  
         <oasis:entry colname="col6">Rectangular</oasis:entry>  
         <oasis:entry colname="col7">0.009</oasis:entry>  
         <oasis:entry colname="col8">0.006</oasis:entry>  
         <oasis:entry colname="col9">0.009</oasis:entry>  
         <oasis:entry colname="col10">0.39</oasis:entry>  
         <oasis:entry colname="col11">0.88</oasis:entry>  
         <oasis:entry colname="col12">0.27</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">2.13</oasis:entry>  
         <oasis:entry colname="col4">0.42</oasis:entry>  
         <oasis:entry colname="col5">0.59</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.011</oasis:entry>  
         <oasis:entry colname="col8">0.001</oasis:entry>  
         <oasis:entry colname="col9">0.004</oasis:entry>  
         <oasis:entry colname="col10">0.67</oasis:entry>  
         <oasis:entry colname="col11">0.06</oasis:entry>  
         <oasis:entry colname="col12">0.05</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">2.13</oasis:entry>  
         <oasis:entry colname="col4">1.41</oasis:entry>  
         <oasis:entry colname="col5">1.98</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.011</oasis:entry>  
         <oasis:entry colname="col8">0.004</oasis:entry>  
         <oasis:entry colname="col9">0.012</oasis:entry>  
         <oasis:entry colname="col10">0.68</oasis:entry>  
         <oasis:entry colname="col11">0.67</oasis:entry>  
         <oasis:entry colname="col12">0.56</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">1.82</oasis:entry>  
         <oasis:entry colname="col4">1.04</oasis:entry>  
         <oasis:entry colname="col5">1.51</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.009</oasis:entry>  
         <oasis:entry colname="col8">0.006</oasis:entry>  
         <oasis:entry colname="col9">0.006</oasis:entry>  
         <oasis:entry colname="col10">0.49</oasis:entry>  
         <oasis:entry colname="col11">1.11</oasis:entry>  
         <oasis:entry colname="col12">0.33</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">7</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type A</oasis:entry>  
         <oasis:entry colname="col3">1.82</oasis:entry>  
         <oasis:entry colname="col4">1.04</oasis:entry>  
         <oasis:entry colname="col5">1.51</oasis:entry>  
         <oasis:entry colname="col6">Normal</oasis:entry>  
         <oasis:entry colname="col7">0.009</oasis:entry>  
         <oasis:entry colname="col8">0.006</oasis:entry>  
         <oasis:entry colname="col9">0.006</oasis:entry>  
         <oasis:entry colname="col10">0.49</oasis:entry>  
         <oasis:entry colname="col11">1.11</oasis:entry>  
         <oasis:entry colname="col12">0.33</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type B</oasis:entry>  
         <oasis:entry colname="col3">12.3</oasis:entry>  
         <oasis:entry colname="col4">10.9</oasis:entry>  
         <oasis:entry colname="col5">9.18</oasis:entry>  
         <oasis:entry colname="col6">Rectangular</oasis:entry>  
         <oasis:entry colname="col7">0.064</oasis:entry>  
         <oasis:entry colname="col8">0.057</oasis:entry>  
         <oasis:entry colname="col9">0.057</oasis:entry>  
         <oasis:entry colname="col10">22.4</oasis:entry>  
         <oasis:entry colname="col11">40.6</oasis:entry>  
         <oasis:entry colname="col12">12.0</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">Type B</oasis:entry>  
         <oasis:entry colname="col3">17.6</oasis:entry>  
         <oasis:entry colname="col4">8.89</oasis:entry>  
         <oasis:entry colname="col5">20.6</oasis:entry>  
         <oasis:entry colname="col6">Rectangular</oasis:entry>  
         <oasis:entry colname="col7">0.092</oasis:entry>  
         <oasis:entry colname="col8">0.047</oasis:entry>  
         <oasis:entry colname="col9">0.13</oasis:entry>  
         <oasis:entry colname="col10">46.4</oasis:entry>  
         <oasis:entry colname="col11">26.6</oasis:entry>  
         <oasis:entry colname="col12">60.7</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry namest="col1" nameend="col12" align="center">Density measurement by SMPS–QCM </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry namest="col1" nameend="col5">Combined standard uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>) (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">g</mml:mi><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mi mathvariant="normal">cm</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) </oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry namest="col7" nameend="col12">Contribution of the combined uncertainty in the  </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry namest="col7" nameend="col12">density measurement <inline-formula><mml:math display="inline"><mml:mrow><mml:mfenced close=")" open="("><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ρ</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></inline-formula> (%) </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">AS</oasis:entry>  
         <oasis:entry namest="col2" nameend="col3">SC </oasis:entry>  
         <oasis:entry namest="col4" nameend="col5">AN </oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry namest="col7" nameend="col8">AS </oasis:entry>  
         <oasis:entry namest="col9" nameend="col10">SC </oasis:entry>  
         <oasis:entry namest="col11" nameend="col12">AN </oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">0.24</oasis:entry>  
         <oasis:entry namest="col2" nameend="col3">0.19 </oasis:entry>  
         <oasis:entry namest="col4" nameend="col5">0.28 </oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry namest="col7" nameend="col8">13.6 </oasis:entry>  
         <oasis:entry namest="col9" nameend="col10">9.13 </oasis:entry>  
         <oasis:entry namest="col11" nameend="col12">16.6 </oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S3.SS2.SSSx1" specific-use="unnumbered">
  <title>Uncertainty due to mass collected at different stages of QCM</title>
      <p>The mass concentration of the particles is considered to be the summation of
the mass concentrations obtained from the different stages of QCM (i.e.
total mass, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mtext>p</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. This mass concentration is further converted to mass
using QCM air volume (the product of inlet flow rate and sampling time).
The uncertainty (type A) in mass measurement <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is
estimated using  the following equation:
              <disp-formula id="Ch1.E9" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced close=")" open="("><mml:msub><mml:mi>m</mml:mi><mml:mrow><mml:mtext>p</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mover accent="true"><mml:mi>m</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>p</mml:mtext></mml:msub></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mrow><mml:mtext>p</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the mass of particles obtained from QCM for sample
<inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> (i.e. total mass of particles collected on different stages of QCM),
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>m</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>p</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the mean mass over <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mrow><mml:mtext>p</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> is
the number of samples (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn>12</mml:mn></mml:mrow></mml:math></inline-formula>).</p>
      <p>For example, the calculated mean mass of ammonium sulfate (AS) particles is
27.4 <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g, and the estimated standard uncertainty for ammonium sulfate
particle mass is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>1.45</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx2" specific-use="unnumbered">
  <title>Uncertainty due to sampling time</title>
      <p>The sampling time of sample <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> in QCM is 120 s which is equivalent to SMPS up-scan sampling time for a sample <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>. Because the sampling time for a sample in
both QCM and CPC is the same, uncertainty due to sampling time is equally
contributed to mass and volume measurements, respectively, and hence assumed
to nullify the effect in effective density measurement result.
Therefore we have not considered this component in the uncertainty
estimation.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx3" specific-use="unnumbered">
  <title>Uncertainty due to QCM inlet flow rate</title>
      <p>The QCM inlet flow (0.24 L min<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is calibrated with the reference flow
meter (Gilian Gilibrator2, SP100IZ, World Precision Instruments) traceable
to SI unit through NIST, USA. Standard uncertainty in flow rate (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>q</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
at the inlet of  the QCM during sampling is estimated using  the following
equation:
              <disp-formula id="Ch1.E10" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>q</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced open="(" close=")"><mml:msub><mml:mi>q</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:mover accent="true"><mml:mi>q</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>q</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the QCM inlet flow rate during sample <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, and  <inline-formula><mml:math display="inline"><mml:mover accent="true"><mml:mi>q</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula> is
the mean flow rate measured during the whole duration of sampling (for <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>
number of samples).</p>
      <p>The uncertainty contribution in mass of AS particles due to  the QCM inlet flow
rate is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>1.98</mml:mn></mml:mrow></mml:math></inline-formula> %. The percentage is calculated as <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>q</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mi>q</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle></mml:math></inline-formula> %. The corresponding standard uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
(type A uncertainty based on repeatable measurement
and normal distribution) is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>0.54</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g using the
following equation:
              <disp-formula id="Ch1.E11" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>m</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>q</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mi>q</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mn>0.01.</mml:mn></mml:mrow></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S3.SS2.SSSx4" specific-use="unnumbered">
  <title>Uncertainty due to variation in crystal frequency</title>
      <p>In  the QCM, each impactor stage constitutes a nozzle, two open-face quartz
crystals, and electronics circuits for the crystals. One of the crystals,
the sensing crystal, is placed close to the nozzle exit and collects
particles. The other crystal, the reference crystal, does not collect
particles but is there to nullify temperature or other effects on both
crystals. The amount of frequency change of the signal output is in direct
proportion to the particle mass deposited on the sensing crystal. Therefore, the
frequency of each stage of QCM is continuously monitored prior to and after the
sampling. The uncertainty due to crystal frequency <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
is estimated using Eq. (12) below, which is based on the
deviation in mean frequency difference of sensing and reference crystals of
all the stages of  the QCM:
              <disp-formula id="Ch1.E12" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced close=")" open="("><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>f</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:mover accent="true"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>f</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the mean frequency difference between sensing and
reference crystals of all the stages of  the QCM for sample <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>,  the <inline-formula><mml:math display="inline"><mml:mover accent="true"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>
is the mean over <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>f</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> is the total number of
observations during the whole duration of sampling.</p>
      <p>The uncertainty contribution in mass of AS particles due to variation in
crystal frequency is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>3.7</mml:mn></mml:mrow></mml:math></inline-formula> %. The percentage is calculated as
<inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle></mml:math></inline-formula> %. The corresponding
standard uncertainty, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (type A and normal
distribution) is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>1.01</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g using
              <disp-formula id="Ch1.E13" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>m</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>f</mml:mi></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mn>0.01.</mml:mn></mml:mrow></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S3.SS2.SSSx5" specific-use="unnumbered">
  <title>Uncertainty due to QCM collection efficiency</title>
      <p>The QCM (PC-2) is a 10-stage impactor and the collection efficiencies for all
stages are reported by Horton et al. (1992). In this study we have assumed that
the collection efficiencies of all the stages are a function of particle
diffusion loss. The percentage uncertainty contribution in  the mass of ammonium
sulfate due to QCM collection efficiencies is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>3.73</mml:mn></mml:mrow></mml:math></inline-formula> %. This
percentage is a mean value of  the collection efficiencies of all the stages as
reported by Horton et al. (1992), and was not measured during the sampling
in this work. Hence the uncertainty contribution is considered as type B
uncertainty. The corresponding standard uncertainty (i.e. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
assuming rectangular distribution is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>0.59</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g for AS particles:
              <disp-formula id="Ch1.E14" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mover accent="true"><mml:mi>m</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>p</mml:mtext></mml:msub><mml:mo>×</mml:mo><mml:mn>3.73</mml:mn><mml:mo>×</mml:mo><mml:mn>0.01</mml:mn><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:msqrt><mml:mn mathvariant="normal">3</mml:mn></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>The combined relative standard uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:mfenced close=")" open="("><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></inline-formula> in
particle mass measurement using QCM including both type A and type B is
estimated by
              <disp-formula id="Ch1.E15" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>A</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>B</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>m</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>A</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (i.e. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>B</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (i.e. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>m</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are the standard uncertainty sources
from type A and type B, respectively. The estimated combined relative standard
uncertainty in the measurement of AS particle mass using Eqs. (9)–(15) is
estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>0.07</mml:mn></mml:mrow></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2.SSS2">
  <?xmltex \opttitle{Uncertainty in particle volume calculation (using DMA\,$+$\,CPC)}?><title>Uncertainty in particle volume calculation (using DMA <inline-formula><mml:math display="inline"><mml:mo>+</mml:mo></mml:math></inline-formula> CPC)</title>
      <p>The SMPS consists of an electrostatic
classifier (EC, including an impactor and Kr-85 bipolar charger),
a DMA and a CPC. The radioactive source (Kr-85 gas) imposes a Boltzmann charge
distribution on aerosol particles. Aerosol particles then pass through the
DMA. Here, an electric field acts on the
charged particles, such that they are classified according to their
electrical mobility equivalent diameter and then the resulting size-selected
particles enter  the  CPC. In the  CPC, particles are counted in an optical
detector, which uses the scattered light of a laser source focused onto the
particle stream (Hinds, 1999). The particle number concentration for every
size bin (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mtext>smps</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, which is a function of channel raw count
(<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>n</mml:mi><mml:mi>i</mml:mi><mml:mo>′</mml:mo></mml:msubsup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of the CPC through the CPC dilution factor (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, the
sampling time (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, the sampling flow rate (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and the counting
efficiency (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and can be represented as (Buonanno et al.,
2009)
              <disp-formula id="Ch1.E16" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mrow><mml:mtext>smps</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msubsup><mml:mi>n</mml:mi><mml:mi>i</mml:mi><mml:mo>′</mml:mo></mml:msubsup><mml:mi mathvariant="italic">φ</mml:mi></mml:mrow><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mi mathvariant="italic">θ</mml:mi><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>The channel volume concentration (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mtext>smps</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is evaluated from
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mrow><mml:mtext>smps</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> by means of

                  <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E17"><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mtext>smps</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mtd><mml:mtd><mml:mrow><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:msubsup><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">3</mml:mn></mml:msubsup><mml:msub><mml:mi>N</mml:mi><mml:mrow><mml:mtext>smps</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:msubsup><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">3</mml:mn></mml:msubsup><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msubsup><mml:mi>n</mml:mi><mml:mi>i</mml:mi><mml:mo>′</mml:mo></mml:msubsup><mml:mi mathvariant="italic">φ</mml:mi></mml:mrow><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mi mathvariant="italic">θ</mml:mi><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mtr><mml:mtd/><mml:mtd><mml:mrow><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:msubsup><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">3</mml:mn></mml:msubsup><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mtext>d</mml:mtext><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mtext>dlog</mml:mtext><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>w</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>

              where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> represents the equivalent volumetric diameter (the
diameter of a sphere having the same volume as the particle under
examination), d<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mtext>dlog</mml:mtext><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the normalized number
concentration for each channel and <inline-formula><mml:math display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>w</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> represents the channel
width.</p>
      <p>In this study, the hypothesis of spherical particle is assumed,
hence with this approximation, volumetric and mobility diameter are
considered to be equal (Sioutas, et al., 1999; McMurry et al., 2002). The
total volume concentration through the SMPS (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mtext>smps</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is obtained as the
sum of volume concentration of <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> number of bins:
              <disp-formula id="Ch1.E18" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mtext>smps</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mtext>smps</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S3.SS2.SSSx6" specific-use="unnumbered">
  <title>Uncertainty in particle volume estimated from CPC data</title>
      <p>The volume of inorganic salt particles is calculated from the count mean
diameter (Hinds, 1999; Sarangi et al., 2015) obtained from the size
distribution data of  the CPC for a sample <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, CPC inlet flow rate (0.24 L min<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
and DMA up-scan time (120 s). The mathematical expression for
the estimation of standard uncertainty (type A) in volume of the particles is
              <disp-formula id="Ch1.E19" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced close=")" open="("><mml:msub><mml:mi>V</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:mover accent="true"><mml:mi>V</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>V</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the volume of AS obtained from CPC samples <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mover accent="true"><mml:mi>V</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>
is the mean volume determined from <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> number of samples.</p>
      <p>For AS particles (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn>12</mml:mn></mml:mrow></mml:math></inline-formula>), the mean volume determined is <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.91</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>17</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> and the standard uncertainty estimated is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>2.13</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx7" specific-use="unnumbered">
  <title>Uncertainty in volume due to assumption that particles are
spherical</title>
      <p>For spherical particles, the dynamic shape factor (DSF, <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">χ</mml:mi></mml:math></inline-formula>) is 1 and in
most other cases (e.g. non-spherical particles) it is larger than 1. In such
cases,  the electrical mobility diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, considered for DMA size
segregation) is not equivalent to  the aerodynamic diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>a</mml:mtext></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:math></inline-formula> considered
for QCM size segregation). Therefore, it is important to estimate the
uncertainty due to  the DSF in particle volume and thus in particle density
measurement.</p>
      <p>It is important to note that the DSF is not a constant – it changes with
pressure, particle size, and as a result of particle orientation in electric
or aerodynamic flow fields. For inorganic salts, such as ammonium sulfate
and sodium chloride, the shape correction factor has been taken as 1.04
(Zelenyuk et al., 2006) and 1.08 (Hinds, 1999), respectively. In this study we have assumed
the shape factor for ammonium nitrate as 1.08. Therefore, the
correction in particle size can be calculated as
              <disp-formula id="Ch1.E20" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mtext>d</mml:mtext><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>m</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:mi mathvariant="italic">χ</mml:mi><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>m</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:mtext>d</mml:mtext><mml:msub><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the correction in diameter. <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">χ</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> are the
DSFs for spherical and original inorganic salt particle (non-spherical),
respectively. Therefore correction in the volume (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mtext>m</mml:mtext></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> of particles can
be calculated from the correction in mobility diameter:
              <disp-formula id="Ch1.E21" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mtext>m</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mfenced open="(" close=")"><mml:mtext>d</mml:mtext><mml:msubsup><mml:mi>d</mml:mi><mml:mtext>m</mml:mtext><mml:mn mathvariant="normal">3</mml:mn></mml:msubsup></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            and then the standard uncertainty (type A) involved due to DSF (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is
              <disp-formula id="Ch1.E22" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced open="(" close=")"><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mtext>m</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>m</mml:mtext></mml:msub></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mtext>m</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the corrected volume of sample <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula> of CPC data, and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>m</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the mean corrected volume derived from <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> number
of samples of CPC data.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4" specific-use="star"><caption><p>The uncertainty budget in the measurement of PSL-60 nm reference
particles.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="center"/>
     <oasis:colspec colnum="6" colname="col6" align="center"/>
     <oasis:thead>
       <oasis:row>  
         <oasis:entry colname="col1">Source of</oasis:entry>  
         <oasis:entry colname="col2">Probability</oasis:entry>  
         <oasis:entry namest="col3" nameend="col4" align="center">Standard </oasis:entry>  
         <oasis:entry colname="col5">Sensitivity</oasis:entry>  
         <oasis:entry colname="col6">Degree of</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">uncertainty (nm)</oasis:entry>  
         <oasis:entry colname="col2">distribution</oasis:entry>  
         <oasis:entry rowsep="1" namest="col3" nameend="col4" align="center">uncertainty (nm) </oasis:entry>  
         <oasis:entry colname="col5">coefficient</oasis:entry>  
         <oasis:entry colname="col6">freedom</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">Sample</oasis:entry>  
         <oasis:entry colname="col4">Sample</oasis:entry>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>
       </oasis:row>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"/>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3">SET-1</oasis:entry>  
         <oasis:entry colname="col4">SET-2</oasis:entry>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">Mode peak (Repeatability)</oasis:entry>  
         <oasis:entry colname="col2">Normal-TypeA</oasis:entry>  
         <oasis:entry colname="col3">0.380</oasis:entry>  
         <oasis:entry colname="col4">0.420</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6">4</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">CMD correction</oasis:entry>  
         <oasis:entry colname="col2">Normal-TypeA</oasis:entry>  
         <oasis:entry colname="col3">0.199</oasis:entry>  
         <oasis:entry colname="col4">0.140</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6">4</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Diffusion correction</oasis:entry>  
         <oasis:entry colname="col2">Rectangular-TypeB</oasis:entry>  
         <oasis:entry colname="col3">0.161</oasis:entry>  
         <oasis:entry colname="col4">0.118</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Charge correction</oasis:entry>  
         <oasis:entry colname="col2">Rectangular-TypeB</oasis:entry>  
         <oasis:entry colname="col3">0.109</oasis:entry>  
         <oasis:entry colname="col4">0.119</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Impactor flow</oasis:entry>  
         <oasis:entry colname="col2">Rectangular-TypeB</oasis:entry>  
         <oasis:entry colname="col3">0.016</oasis:entry>  
         <oasis:entry colname="col4">0.016</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Sheath flow</oasis:entry>  
         <oasis:entry colname="col2">Rectangular-TypeB</oasis:entry>  
         <oasis:entry colname="col3">0.00004</oasis:entry>  
         <oasis:entry colname="col4">0.00005</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Bypass flow</oasis:entry>  
         <oasis:entry colname="col2">Rectangular-TypeB</oasis:entry>  
         <oasis:entry colname="col3">0.057</oasis:entry>  
         <oasis:entry colname="col4">0.058</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Certificate value of SRM 1964</oasis:entry>  
         <oasis:entry colname="col2">Normal-TypeB</oasis:entry>  
         <oasis:entry colname="col3">0.310</oasis:entry>  
         <oasis:entry colname="col4">0.310</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Uncertainty (at manufacturer site)</oasis:entry>  
         <oasis:entry colname="col2">Normal-TypeB</oasis:entry>  
         <oasis:entry colname="col3">0.551</oasis:entry>  
         <oasis:entry colname="col4">0.559</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Reproducibility</oasis:entry>  
         <oasis:entry colname="col2">Normal-TypeA</oasis:entry>  
         <oasis:entry colname="col3">0.274</oasis:entry>  
         <oasis:entry colname="col4">0.274</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6">2</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Combined uncertainty</oasis:entry>  
         <oasis:entry colname="col2">–</oasis:entry>  
         <oasis:entry colname="col3">0.750</oasis:entry>  
         <oasis:entry colname="col4">0.763</oasis:entry>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Expanded uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>)</oasis:entry>  
         <oasis:entry colname="col2">–</oasis:entry>  
         <oasis:entry colname="col3">1.500</oasis:entry>  
         <oasis:entry colname="col4">1.525</oasis:entry>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">∞</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p>Based on repeated measurements (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn>12</mml:mn></mml:mrow></mml:math></inline-formula>), the standard uncertainty involved
due to DSF in the measurement of volume of AS particles is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>2.12</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx8" specific-use="unnumbered">
  <title>DMA calibration: uncertainty in volume due to DMA particle size
segregation</title>
      <p>In this study, calibration of the  DMA was
performed using standard polystyrene latex (PSL) 60 and 100 nm particles,
which are traceable to SI through NIST, USA. Here  the uncertainty of particle
volume using PSL-60 nm is considered because it is used routinely in the
calibration of DMA before and after sampling.</p>
      <p>Based on the particle size distribution obtained from  the SMPS, the observed
mode peak is represented by the size peak of standard PSL particles. The
experiment was repeated five times on each of 3 different days. The
statistical analyses (count mean diameter (CMD), geometric mean diameter
(GMD), geometric standard deviation (GSD), mean mode diameter (MD),
repeatability and reproducibility) of particle size obtained from size
distribution were performed. Uncertainty components due to instrument
calibration (impactor flow, sheath flow, bypass flow, CPC inlet flow),
instrumental measurement (diffusion correction, charge correction, CMD
correction, repeatability, reproducibility) and calibration standard
(certificate value of particle standard used, calibration uncertainty at the
manufacturer site) were included in the budget estimation of the uncertainty
in particle size measurement (Table 4; Sarangi et al., 2014):

                  <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E23"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:msub><mml:mi>x</mml:mi><mml:mtext>psl</mml:mtext></mml:msub><mml:mo>×</mml:mo><mml:mn>0.01</mml:mn><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:msqrt><mml:mn mathvariant="normal">3</mml:mn></mml:msqrt></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E24"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>x</mml:mi><mml:mtext>psl</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>d</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>psl</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mn>100</mml:mn><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

              where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>x</mml:mi><mml:mtext>psl</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the percentage of uncertainty in PSL-60 nm particles.
<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>u</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>d</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>psl</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are the estimated combined standard uncertainty and the
obtained mean mode of PSL-60 nm by DMA calibration, respectively.</p>
      <p>The uncertainty reported for PSL-60 nm in certificate is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>0.63</mml:mn></mml:mrow></mml:math></inline-formula> nm
with coverage factor <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>. The uncertainty estimated from DMA calibration
using PSL-60 nm by Eq. (23) is <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>55.62</mml:mn><mml:mo>±</mml:mo><mml:mn>1.53</mml:mn></mml:mrow></mml:math></inline-formula> nm (with coverage factor
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>). The standard uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (type B and
rectangular distribution) involved due to PSL-60 nm in the measurement of
volume of AS particles is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>1.62</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx9" specific-use="unnumbered">
  <title>Uncertainty in volume due to particle diffusion loss</title>
      <p>Diffusion correction was done using a program (TSI-Aerosol Instrument
Manager<sup>®</sup> (AIM) Software) which is based on
the loss of the particles along the SMPS channel (particle loss on the
impactor inlet, the bi-polar neutralizer, internal plumbing, the tubing to
the DMA and CPC). Using  the built-in TSI-AIM (version 9.0.0.0, 15:32:53,
11 November 2010) algorithm, the diffusion correction was done and a corrected
number concentration of the particles was obtained. Because the particle CMD
is the function of particle number concentration (Hinds, 1999), the
uncertainty due to diffusion loss of particles, which affects the volume of
particles is estimated as

                  <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E25"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mtext>d</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mfenced open="(" close=")"><mml:mo>(</mml:mo><mml:msup><mml:mtext>CMD</mml:mtext><mml:mo>′</mml:mo></mml:msup><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:mtext>CMD</mml:mtext><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E26"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msup><mml:mtext>CMD</mml:mtext><mml:mo>′</mml:mo></mml:msup><mml:mo>=</mml:mo><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msup><mml:mi>N</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mi>N</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>×</mml:mo><mml:mtext>CMD</mml:mtext><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

              where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mtext>d</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the diffusion corrected volume, and <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>N</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> are the
total particle number concentrations with diffusion correction and without
diffusion correction over a size range 10–478 nm, respectively.</p>
      <p>The standard uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> involved due to
diffusion correction (type A uncertainty based on repeated measurement and
normal distribution) in the measurement of volume is then estimated as
              <disp-formula id="Ch1.E27" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced close=")" open="("><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mi>d</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mi>d</mml:mi></mml:msub></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where the subscript <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>  denotes individual samples. <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mi>d</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the
mean diffusion-corrected volume and <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> is the total number of samples.</p>
      <p>Using Eq. (27), the standard uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
involved in volume of AS particles (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn>12</mml:mn></mml:mrow></mml:math></inline-formula>) is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>2.13</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx10" specific-use="unnumbered">
  <title>Uncertainty in volume due to particle multiple charges</title>
      <p>Multiple charges on a particle increase its mobility. Since the TSI-AIM
software assumes that a particle has only one charge, the effect of multiple
charges on a particle allows the particle to be incorrectly binned into a
smaller-sized particle channel. Therefore, multiple charge correction is
performed using the built-in TSI-AIM (version 9.0.0.0, 15: 32: 53,
11 November 2010) algorithm (which is based on Wiedensohler, 1988; Kim et
al., 2005) that attempts to correct the sample data from the effects of the
multiple charged particles. The mathematical expression for estimation of
uncertainty in volume due to multiple charges is similar to that for
uncertainty due to particle diffusion loss:

                  <disp-formula specific-use="align" content-type="numbered"><mml:math display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E28"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced open="(" close=")"><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mtext>c</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>c</mml:mtext></mml:msub></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E29"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mtext>c</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mfenced close=")" open="("><mml:mo>(</mml:mo><mml:msup><mml:mtext>CMD</mml:mtext><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:mtext>CMD</mml:mtext><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:mfenced></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E30"><mml:mtd/><mml:mtd/><mml:mtd><mml:mrow><mml:msup><mml:mtext>CMD</mml:mtext><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msup><mml:mi>N</mml:mi><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow><mml:mi>N</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>×</mml:mo><mml:mtext>CMD</mml:mtext><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula>

              where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mrow><mml:mtext>c</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mtext>c</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> are the multiple charge-corrected and mean
multiple charge-corrected volumes, respectively. <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>N</mml:mi><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula> are total
particle number concentrations with and without multiple charge corrections,
respectively.</p>
      <p>The standard uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">5</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> involved due to
multiple charge correction (type A uncertainty based on repeated measurement
and normal distribution) in the measurement of volume of AS particle is
<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>2.13</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx11" specific-use="unnumbered">
  <title>Uncertainty in particle volume due to CPC inlet flow rate</title>
      <p>The CPC inlet flow (0.24 L min<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is calibrated with the reference flow
meter (Gilian Gilibrator2, SP100IZ, World Precision Instruments). Standard
uncertainty in flow rate (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> at the inlet of  the CPC during
sampling is estimated using
              <disp-formula id="Ch1.E31" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced open="(" close=")"><mml:msubsup><mml:mi>q</mml:mi><mml:mi>i</mml:mi><mml:mo>′</mml:mo></mml:msubsup><mml:mo>-</mml:mo><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>q</mml:mi><mml:mi>i</mml:mi><mml:mo>′</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> is the CPC inlet flow rate during sample <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:math></inline-formula>
is the mean flow rate measured during the whole duration of sampling (for <inline-formula><mml:math display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>
number of samples).</p>
      <p>The uncertainty contribution in volume of AS particles due to CPC inlet flow
rate is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>0.95</mml:mn></mml:mrow></mml:math></inline-formula> %. This percentage is calculated using <inline-formula><mml:math display="inline"><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle></mml:math></inline-formula> %. The corresponding standard uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>  (type A and normal distribution) is estimated to be
<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>1.82</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> using
              <disp-formula id="Ch1.E32" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mrow><mml:msup><mml:mi>q</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mn>0.01.</mml:mn></mml:mrow></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S3.SS2.SSSx12" specific-use="unnumbered">
  <title>Uncertainty in particle volume due to CPC dilution factor</title>
      <p>The CPC dilution factor is the ratio of aerosol sample flow rate (equivalent to
CPC inlet flow rate) to sheath flow rate:
              <disp-formula id="Ch1.E33" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">θ</mml:mi><mml:mrow><mml:msup><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">θ</mml:mi></mml:math></inline-formula> is the aerosol sample flow rate and <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is the DMA
sheath flow rate (fixed at 0.48 L min<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Both the sample flow rate
and sheath flow rate are measured with the reference flow meter (Gilian
Gilibrator2). Standard uncertainty due to CPC dilution factor (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> at
the inlet of CPC during sampling is estimated using
              <disp-formula id="Ch1.E34" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:msqrt><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>n</mml:mi></mml:munderover><mml:msup><mml:mfenced close=")" open="("><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:mover accent="true"><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:msqrt><mml:mi>n</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>The uncertainty contribution in volume of ammonium sulfate due to  the CPC
dilution factor flow rate is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>0.95</mml:mn></mml:mrow></mml:math></inline-formula> %. This percentage is calculated
using <inline-formula><mml:math display="inline"><mml:mrow><mml:mstyle displaystyle="false"><mml:mfrac style="text"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula>. The
corresponding standard uncertainty  <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">7</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (type A and
normal distribution) is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>1.82</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula> using
              <disp-formula id="Ch1.E35" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">7</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mover accent="true"><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:mn>0.01.</mml:mn></mml:mrow></mml:math></disp-formula></p>
</sec>
<sec id="Ch1.S3.SS2.SSSx13" specific-use="unnumbered">
  <title>Uncertainty in particle volume due to CPC counting accuracy</title>
      <p>CPC counting uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mo>′</mml:mo></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is directly taken from the
CPC calibration certificate of the manufacturer, and CPC counting accuracy
(for particle size 10–478 nm) is further checked using a filter-based
gravimetric technique (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (Aggarwal et al., 2013).
The standard uncertainty in particle volume due to CPC counting accuracy in
the measurement of particle volume <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (type B uncertainty) is expressed as
              <disp-formula id="Ch1.E36" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msup><mml:mfenced close=")" open="("><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mo>′</mml:mo></mml:msup></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>The standard uncertainty (<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> in volume measurement of AS particles
due to CPC counting accuracy is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>12.3</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>. Here we discuss the detailed procedure of the calculation
of CPC counting accuracy both using CPC certificate and the filter-based
gravimetric technique.</p>
      <p>From the manufacturer specification it has been reported that the CPC (TSI
model 3788) particle concentration accuracy is <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>10</mml:mn></mml:mrow></mml:math></inline-formula> % for
400 000 # cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (i.e. particles cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. Therefore, the
standard uncertainty (assuming 10 % uncertainty, rectangular distribution
and type B uncertainty) <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>(</mml:mo><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> in particle volume measurement due to
CPC counting accuracy is
              <disp-formula id="Ch1.E37" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:msup><mml:mi>V</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:mn>10</mml:mn><mml:mo>×</mml:mo><mml:mn>0.01</mml:mn><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:msqrt><mml:mn mathvariant="normal">3</mml:mn></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
            The standard uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> for AS particles is
estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>1.1</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
      <p>The filter-based gravimetric technique has been discussed elsewhere (Aggarwal et
al., 2013). Briefly, dried ammonium sulfate particles were introduced to
SMPS with a sample flow rate of 0.6 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and sheath flow rate of
6 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Particles of size range 14–615 nm were segregated by DMA and
number concentration was measured by CPC which was operated with a flow rate
of 0.3 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Also, after DMA a Quartz filter (47 mm which was
pre-baked at 450<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>, pre-conditioned and pre-weighted) was placed to
collect particles with a flow rate of 0.3 L min<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> and simultaneously to
measure the mass of the particles downstream of the DMA. After 30 min of
particle sampling, the filter was conditioned and weighed.</p>
      <p>Using CPC particle count data  the CPC-derived particle volume was calculated
as
              <disp-formula id="Ch1.E38" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msup><mml:mi>V</mml:mi><mml:mo>′</mml:mo></mml:msup><mml:mo>=</mml:mo><mml:mi>v</mml:mi><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi mathvariant="italic">π</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:mfrac></mml:mstyle><mml:mo>×</mml:mo><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mn>105</mml:mn></mml:munderover><mml:msubsup><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow><mml:mn mathvariant="normal">3</mml:mn></mml:msubsup><mml:mo>×</mml:mo><mml:msubsup><mml:mi>n</mml:mi><mml:mi>i</mml:mi><mml:mo>′</mml:mo></mml:msubsup><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>V</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is the total volume of the size distribution, <inline-formula><mml:math display="inline"><mml:mi>v</mml:mi></mml:math></inline-formula> is the flow
volume that enters  the CPC (calculated from CPC inlet flow and the time of flow),  and
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mtext>ve</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi>n</mml:mi><mml:mi>i</mml:mi><mml:mo>′</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula> are the particle's mobility diameter and number
concentration in bin <inline-formula><mml:math display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, respectively.</p>
      <p>Based on the particle mass collected on the filter, and using  the density of
particle material (e.g. ammonium sulfate), we have calculated the volume of
particles as
              <disp-formula id="Ch1.E39" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msup><mml:mi>V</mml:mi><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>m</mml:mi><mml:mi mathvariant="italic">ρ</mml:mi></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mi mathvariant="italic">ρ</mml:mi></mml:math></inline-formula> is the density of particle material (e.g. in the case of
ammonium sulfate, 1.769 g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> is the mass of the particles
collected on the filter.</p>
      <p>Using this approach, the uncertainty (estimated from the standard deviation
of <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>V</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi>V</mml:mi><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> contribution due to CPC counting accuracy to the total volume of
the AS particles is estimated to be 4.8 %. Therefore, the standard
uncertainty ((<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, assuming rectangular distribution
and type B uncertainty) due to CPC counting accuracy in the measurement of
particle volume is
              <disp-formula id="Ch1.E40" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:mn>4.8</mml:mn><mml:mo>×</mml:mo><mml:mn>0.01</mml:mn><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:msqrt><mml:mn mathvariant="normal">3</mml:mn></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>The <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">8</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> for AS particles is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>5.31</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
</sec>
<sec id="Ch1.S3.SS2.SSSx14" specific-use="unnumbered">
  <title>Uncertainty due to assumption that equivalence of CPC- and QCM-derived
particle volumes</title>
      <p>Both the CPC and QCM are placed equidistant downstream of the DMA.
The inlet flow rates are equal for both of the instruments. Uncertainty
because of the assumption of equivalency of CPC-derived volume (based on CMD
of the distributions) and corresponding particle volume derived from  the QCM
(based on mass obtained from QCM and material density) is about <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>12</mml:mn></mml:mrow></mml:math></inline-formula> %. This is calculated based on the standard deviation between the
CPC- and QCM-derived volumes. Therefore, the standard uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>
due to CPC and QCM volume equivalence (assuming rectangular distribution) in
the measurement of particle volume is estimated as
              <disp-formula id="Ch1.E41" content-type="numbered"><mml:math display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo mathvariant="normal">‾</mml:mo></mml:mover><mml:mo>×</mml:mo><mml:mn>12</mml:mn><mml:mo>×</mml:mo><mml:mn>0.01</mml:mn><mml:mo>×</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:msqrt><mml:mn mathvariant="normal">3</mml:mn></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p>The <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mn mathvariant="normal">9</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> (type B and rectangular distribution) due to the assumption of
CPC- and QCM-derived volume equivalence in AS particles is estimated to be
<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>17.6</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn>19</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msup></mml:math></inline-formula>.</p>
      <p>The combined relative standard uncertainty <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> including type A and type B
uncertainty sources can be defined as
              <disp-formula id="Ch1.E42" content-type="numbered"><mml:math display="block"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi>u</mml:mi><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>A</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:munder><mml:mo movablelimits="false">∑</mml:mo><mml:mi>i</mml:mi></mml:munder><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>B</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>V</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
            where <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>A</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mtext>B</mml:mtext><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>V</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are the standard
uncertainty sources from type A and type B, respectively as discussed in the
above sections.</p>
      <p>The estimated combined relative uncertainty in the volume measurement of AS
particles is estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>0.12</mml:mn></mml:mrow></mml:math></inline-formula>.</p>
      <p>Once the combined relative standard uncertainty for both the mass and volume
is known, then the relative combined standard uncertainty in measurement of
effective density of the particles can be estimated using Eq. (7).</p>
      <p>Therefore, the combined standard uncertainties in the measurement of effective
density of AS, SC and AN are estimated to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.76</mml:mn><mml:mo>±</mml:mo><mml:mn>0.24</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>2.08</mml:mn><mml:mo>±</mml:mo><mml:mn>0.19</mml:mn></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.69</mml:mn><mml:mo>±</mml:mo><mml:mn>0.28</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, respectively. The percentage of estimated
uncertainties in the measurement of the density of AS, SC and AN are
calculated to be 13.6, 9.13 and 16.6 %, respectively.</p>
      <p>The detailed uncertainty budget involving different components in the
measurement of effective density of laboratory-generated aerosol particles
(of AS, SC and AN) is summarized in Table 3. Among  the individual uncertainty
components (Fig. 2), the repeatability of particle mass obtained by QCM, QCM
crystal frequency, CPC counting efficiency, and  the equivalence of CPC- and QCM-derived volume are the major contributors to the expanded uncertainty (at
<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) in comparison to other components, e.g. diffusion correction, charge
correction, CPC inlet flow rate, etc. The contribution of different
components in  the total uncertainty of effective density measurements  varies
with the nature or properties of different salt particles (i.e. hygroscopic
property, solubility, etc). An extended study is needed to explain these
differences in future.</p>
</sec>
</sec>
<sec id="Ch1.S3.SS3">
  <title>Ambient aerosol measurement</title>
      <p>After successful measurement of laboratory-generated aerosol particles, the
experimental setup was used for the measurement of effective density of
ambient aerosols. The measurements were carried out at the National Physical
Laboratory (NPL, <uri>http://www.nplindia.org/</uri>), New Delhi, which can be
considered as the representative site with a mixture of residential,
biogenic, biomass-burning and traffic emissions. Because meteorological
conditions/data during mid-November in Delhi are also known to be
representative of the year-round mean data, therefore 1 week of measurements
were conducted during 12–18 November (Wednesday–Tuesday), 2014.</p>
      <p>Although we  conducted density measurement from 8:00 to 19:00 h (local
time), here we report mid-day (10:00–13:00 LT) data for which we have
continuous data without any downtime in the measurements. Also the focus of
the discussion here is to better understand the effect of the photochemistry of
particles (secondary aerosols) versus their size/morphology and bulk
composition on density, and thus mid-day data are considered here.</p>
      <p>The mid-day mean over the 7 days of the measurement period of particle number
concentration (ranged between (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>3.1</mml:mn><mml:mo>±</mml:mo><mml:mn>0.52</mml:mn><mml:mo>)</mml:mo><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> to (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>4.8</mml:mn><mml:mo>±</mml:mo><mml:mn>1.2</mml:mn><mml:mo>)</mml:mo><mml:mo>×</mml:mo><mml:msup><mml:mn>10</mml:mn><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> particles cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, count mean diameter (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>82.8</mml:mn><mml:mo>±</mml:mo><mml:mn>6.5</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>125.7</mml:mn><mml:mo>±</mml:mo><mml:mn>11.7</mml:mn></mml:mrow></mml:math></inline-formula> nm ), effective density (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.12</mml:mn><mml:mo>±</mml:mo><mml:mn>0.34</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.46</mml:mn><mml:mo>±</mml:mo><mml:mn>0.19</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, relative humidity (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>33.5</mml:mn><mml:mo>±</mml:mo><mml:mn>4.1</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>43.1</mml:mn><mml:mo>±</mml:mo><mml:mn>2.8</mml:mn></mml:mrow></mml:math></inline-formula> %),
temperature (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>25.5</mml:mn><mml:mo>±</mml:mo><mml:mn>1.5</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>26.3</mml:mn><mml:mo>±</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>C) and gaseous species such
as CO (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>230</mml:mn><mml:mo>±</mml:mo><mml:mn>50</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>555</mml:mn><mml:mo>±</mml:mo><mml:mn>21</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, O<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>95.8</mml:mn><mml:mo>±</mml:mo><mml:mn>16</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>134</mml:mn><mml:mo>±</mml:mo><mml:mn>35</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, NO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>12.6</mml:mn><mml:mo>±</mml:mo><mml:mn>0.11</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>23.9</mml:mn><mml:mo>±</mml:mo><mml:mn>0.32</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>14.5</mml:mn><mml:mo>±</mml:mo><mml:mn>2.2</mml:mn></mml:mrow></mml:math></inline-formula>–<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>30.3</mml:mn><mml:mo>±</mml:mo><mml:mn>6.3</mml:mn></mml:mrow></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>g m<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> are shown in Fig. 4. The overall mean (i.e. mean of
the mid-day mean) of the 7-day measurement period of effective density of
particles is observed to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.28</mml:mn><mml:mo>±</mml:mo><mml:mn>0.12</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. This density
measurement was carried out for ambient aerosol particle size distribution
range of 10–478 nm.</p>
      <p>The observed mid-day particle effective density (range,
1.12–1.46 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>; mean, 1.28 g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> in New Delhi is similar to  the particle effective density measurement data obtained from
different sites around the globe. Yin et al. (2015) reported  a size-resolved
effective density of 50–400 nm urban particles using a TDMA–APM system in
Shanghai during wintertime. The mean effective density was found to
range between 1.36 and 1.55 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> which showed increasing trend with
particle diameter. They observed that for 50 nm particles, the effective
density increased rapidly from 1.35 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at 10:00 LT to
1.51 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at 13:00 LT corresponding to a burst of nucleation and
Aitken mode particles.</p>
      <p>Khlystov et al. (2004) compared the TEOM PM<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn>2.5</mml:mn></mml:msub></mml:math></inline-formula> mass concentrations with
volume concentrations from the SMPS–APS data, and estimated an effective
density of <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.52</mml:mn><mml:mo>±</mml:mo><mml:mn>0.26</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> of urban aerosols during the Pittsburgh
Air Quality Study (PAQS) in summertime. This density is close to
1.56 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>, the density estimated from the average aerosol bulk
chemical composition during  the  PAQS study. Further,  the DMPS–APS and TEOM approach
has been used by Pitz et al. (2008) to determine particle
(&lt; 2.5 <inline-formula><mml:math display="inline"><mml:mi mathvariant="normal">µ</mml:mi></mml:math></inline-formula>m) effective density at an urban site in Augsburg,
Germany. They reported minimum particle density in the morning and afternoon
(<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn>1.5</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, and a maximum (<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:mn>1.8</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> during
mid-day. They suggested that the minima represent fresh primary aerosol
emissions, which were related to traffic soot particles with agglomerate
structure, whereas the maximum is likely due to increased secondary particle
production during mid-day hours and the presence of more aged particles.</p>
      <p>Geller et al. (2006) determined effective densities of atmospheric aerosols
over a size range of 50–414 nm in various locations of the Los Angeles
Basin using a SMPS-APM technique. They reported an effective density of unity or
more for 50 nm particles, indicative of their spherical nature. It was suggested that the lower
density of marine aerosols may be due to the presence of a
significant amount of organics. Riverside aerosols, with an effective density
as high as 1.4–1.5 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> for this particle size especially during
mid-day hours were thought to be generated predominantly from photochemical
reactions.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><caption><p>Mid-day (10:00–13:00 LT) mean (bar represents standard deviation)
of <bold>(a)</bold> number concentration, count mean diameter (CMD), effective
density, and <bold>(b)</bold> relative humidity, temperature and gas
concentrations (CO, O<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula>, SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>, NO<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016-f04.jpg"/>

        </fig>

      <p>Kannosto et al. (2008) reported the mode-resolved density of ultrafine
atmospheric particles (nucleation, Aitken and accumulation mode) measured
using  the  SMPS or DMPS-ELPI technique for 2 weeks during early summer in a boreal
forest environment. The particle density for accumulation mode varied from
1.1–2.0 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (average 1.5 g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> and for Aitken mode from
0.4 to 2.0 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (average 0.97 g cm<inline-formula><mml:math display="inline"><mml:mrow><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>. The density of
nucleation mode particles decreased during the growth process. The density
values for 15 nm particles were 1.2–1.5 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>and for grown 30 nm
particles 0.5–1 g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. They suggested that this observation is
consistent with the present knowledge that the condensing species are
semi-volatile organics emitted from the boreal forest.</p>
      <p>The above discussions suggest that particle density depends more on particle
chemical composition (which changes rapidly while particle growth occurs during the
mid-day period) and morphology than on particle size. To further check this
hypothesis with  the  results in this study, we  compared ambient
gaseous composition with observed densities.</p>
      <p>Figure 5 displays the mean particle effective density versus count mean
diameter over the size range 10–478 nm observed in mid-day during the
sampling days. In each box, the line within the box shows the median
effective density value which corresponds to a CMD value, the top and bottom
lines of the box show the upper and lower quartiles (the 75th and 25th
percentiles) and the top and bottom of the whiskers are set to 90 and 10
percentile. Considering more than 100 scans each day collectively, it was
less often evident that the effective density increased with the particle
mobility diameter, with a mean of <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.12</mml:mn><mml:mo>±</mml:mo><mml:mn>0.3</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>82.84</mml:mn><mml:mo>±</mml:mo><mml:mn>6.51</mml:mn></mml:mrow></mml:math></inline-formula> nm and <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.46</mml:mn><mml:mo>±</mml:mo><mml:mn>0.2</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> at <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>86.39</mml:mn><mml:mo>±</mml:mo><mml:mn>4.49</mml:mn></mml:mrow></mml:math></inline-formula> nm. This
density versus size trend is not exactly the same as observed by Yin et
al. (2015) that material density generally increased with particle size in
the range of 50–400 nm.</p>
      <p>Figure 4a shows 7 consecutive days' mid-day mean effective density and
mean CMD of particles during the sampling period. On the first 5 days, the
effective density and particle size (CMD) show a positive correlation
coefficient (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.61</mml:mn></mml:mrow></mml:math></inline-formula>); however on the remaining 2 days they show a negative
trend with overall (during the  7 days) correlation coefficient <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.14</mml:mn></mml:mrow></mml:math></inline-formula>. Large
variations in particle number concentration including in CMD and effective
density were observed on the  first day, whereas on the last day these variations
were observed to be minimized.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><caption><p>Measured effective density of ambient particles versus their size
(count mean diameter, CMD) during mid-day (10:00–13:00 LT) of 7 consecutive
days of sampling. In each box, the mid-line shows the median effective
density value for  the corresponding CMD value, the top and bottom show the upper
and lower quartiles (the 75th and 25th percentiles), and the top and bottom
of the whiskers are set to 90th and 10th percentile, respectively.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/859/2016/amt-9-859-2016-f05.jpg"/>

        </fig>

      <p>Among gaseous species (Fig. 4b), mid-day mean concentration of O<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> shows
a decreasing trend with the sampling days. Interestingly, CO and NO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula>
present a similar trend with the sampling days with first-day (12 November)
maximum and fifth-day minimum (16 November). Mid-day mean concentration of both
these species shows a continuous increasing trend during the last 3 days of the
campaign (16–18 November). A strong correlation of the  7-day mid-day mean
concentration between these two gases is obtained (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.96</mml:mn></mml:mrow></mml:math></inline-formula>), suggesting
their common source, possibly from traffic-related emission.</p>
      <p>Further, day five (16 November) was Sunday. Recently Gour et al. (2015)
published a detailed report based on 5 years of observation that in New Delhi
CO and NO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> concentration is lower on weekends and public holidays than
during working days. This  further suggested that both of the species
are related with traffic source.</p>
      <p>On the other hand, SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> mid-day mean concentration decreases from the  first
day of the campaign to  the middle of the campaign (15 November) and then shows continuous
increase to the  end of the campaign. Among all the gaseous species (Table 5),
SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> presents a positive correlation coefficient (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.59</mml:mn></mml:mrow></mml:math></inline-formula>) with
particle effective density. Relative humidity (RH) also shows a positive
correlation coefficient (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.52</mml:mn></mml:mrow></mml:math></inline-formula>) with particle effective density. This
suggests that condensation of sulfates and water-vapour  most likely
occurred on smaller particles,  hence influencing the density of the
particles. It is also evident that mid-day particle mean diameter shows a
good/strong correlation with ozone (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.58</mml:mn></mml:mrow></mml:math></inline-formula>), SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.81</mml:mn></mml:mrow></mml:math></inline-formula>) and RH
(<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.51</mml:mn></mml:mrow></mml:math></inline-formula>), while it shows poor correlations with the NO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.35</mml:mn></mml:mrow></mml:math></inline-formula>)
and CO (<inline-formula><mml:math display="inline"><mml:mrow><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.40</mml:mn></mml:mrow></mml:math></inline-formula>). This is consistent with the theory of  the atmospheric
photo-oxidation process of SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> that in the presence of sunlight and
water vapour, O<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> forms an OH radical which oxidizes SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula> to SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:math></inline-formula> and
then forms H<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:math></inline-formula>SO<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">4</mml:mn></mml:msub></mml:math></inline-formula> vapour (Seinfeld and Pandis, 2006). These vapours
contribute to the condensational growth of aerosol particles, and hence to
the increasing effective density of particles.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T5"><caption><p>Correlation coefficient (<inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula>) between mid-day (10:00–13:00 LT)
mean of ambient particle effective density and other atmospheric constituents
during 7 days of sampling in New Delhi in November.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{0.92}[0.92]?><oasis:tgroup cols="8">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col3">CO</oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">NO</mml:mi></mml:mrow></mml:math></inline-formula><inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col5"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col6">RH</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col8"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">1</oasis:entry>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">CO</oasis:entry>  
         <oasis:entry colname="col2">0.54</oasis:entry>  
         <oasis:entry colname="col3">1</oasis:entry>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:mi mathvariant="normal">NO</mml:mi></mml:mrow></mml:math></inline-formula><inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mi>x</mml:mi></mml:msub></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">0.37</oasis:entry>  
         <oasis:entry colname="col3">0.96</oasis:entry>  
         <oasis:entry colname="col4">1</oasis:entry>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">SO</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">0.04</oasis:entry>  
         <oasis:entry colname="col3">0.13</oasis:entry>  
         <oasis:entry colname="col4">0.20</oasis:entry>  
         <oasis:entry colname="col5">1</oasis:entry>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">RH</oasis:entry>  
         <oasis:entry colname="col2">0.32</oasis:entry>  
         <oasis:entry colname="col3">0.10</oasis:entry>  
         <oasis:entry colname="col4">0.21</oasis:entry>  
         <oasis:entry colname="col5">0.45</oasis:entry>  
         <oasis:entry colname="col6">1</oasis:entry>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mi>T</mml:mi></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2">0.26</oasis:entry>  
         <oasis:entry colname="col3">0.41</oasis:entry>  
         <oasis:entry colname="col4">0.22</oasis:entry>  
         <oasis:entry colname="col5">0.08</oasis:entry>  
         <oasis:entry colname="col6"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.54</oasis:entry>  
         <oasis:entry colname="col7">1</oasis:entry>  
         <oasis:entry colname="col8"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ρ</mml:mi><mml:mtext>eff</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>  
         <oasis:entry colname="col2"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.48</oasis:entry>  
         <oasis:entry colname="col3"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.41</oasis:entry>  
         <oasis:entry colname="col4"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.20</oasis:entry>  
         <oasis:entry colname="col5">0.59</oasis:entry>  
         <oasis:entry colname="col6">0.52</oasis:entry>  
         <oasis:entry colname="col7"><inline-formula><mml:math display="inline"><mml:mo>-</mml:mo></mml:math></inline-formula>0.68</oasis:entry>  
         <oasis:entry colname="col8">1</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

<?xmltex \hack{\newpage}?>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <title>Conclusions</title>
      <p>We have presented a method to measure the effective density of aerosol
particles of a size range from 10 to 478 nm. We used an SMPS–QCM approach to
measure particle effective density, for which particle volume is calculated
from size distribution data of  the SMPS and simultaneously mass concentration of
particles is obtained from  the QCM. This approach is simple because of the use
of real-time aerodynamic instrument (QCM). The method is successfully tested
for laboratory-generated particles from the solutions of standard materials
(inorganic salts of known densities). Also the setup is successfully applied
for ambient measurement of particle effective density in New Delhi. To our
knowledge, this is the first time that a detailed uncertainty budget of particle
effective density measurement using the SMPS–QCM technique has been discussed. The
discussed uncertainty measurement method can be applied to similar
instrumental approaches (such as TDMA/SMPS/DMPS/APS-APM/ELPI/TEOM, etc.) used
for particle effective density measurement. Among individual uncertainty
components, repeatability of the  particle mass obtained by QCM,  the QCM crystal
frequency, CPC counting accuracy and equivalence of CPC- and QCM-derived
volume are the major contributors to the expanded uncertainty (at <inline-formula><mml:math display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) in
comparison to other components. This suggests that minimizing the calibration
uncertainties of  the QCM (i.e. in particle mass sensing) and CPC (i.e. in
particle counting) can result in reducing the uncertainty of particle density
measurement. Using this approach, the effective density of laboratory-generated ammonium sulfate, sodium chloride and ammonium nitrate particles
with combined uncertainty is found to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.76</mml:mn><mml:mo>±</mml:mo><mml:mn>0.24</mml:mn></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>13.6</mml:mn></mml:mrow></mml:math></inline-formula> %),
<inline-formula><mml:math display="inline"><mml:mrow><mml:mn>2.08</mml:mn><mml:mo>±</mml:mo><mml:mn>0.19</mml:mn></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>9.13</mml:mn></mml:mrow></mml:math></inline-formula> %) and <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.69</mml:mn><mml:mo>±</mml:mo><mml:mn>0.28</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> (<inline-formula><mml:math display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn>16.6</mml:mn></mml:mrow></mml:math></inline-formula> %), respectively. The ambient measurements (of particle size range:
10–478 nm) revealed that in general, effective density of ambient aerosol
increases with the increase in particle size during mid-day hours during the
sampling days in November in New Delhi. However, this particle growth is likely
governed by mid-day photochemistry of the  sulfate secondary aerosol
formation process. The mid-day mean effective density of ambient particles
(10–478 nm) during  the 7 days of sampling is obtained to be <inline-formula><mml:math display="inline"><mml:mrow><mml:mn>1.28</mml:mn><mml:mo>±</mml:mo><mml:mn>0.12</mml:mn></mml:mrow></mml:math></inline-formula> g cm<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula>. Our results of mid-day measurement of ambient particle
effective density with other atmospheric constituents suggest that particle
effective density is largely dependent on particle chemistry.</p>
</sec>

      
      </body>
    <back><ack><title>Acknowledgements</title><p>The authors thank the  Director of  the CSIR-National Physical Laboratory, New Delhi for
providing all instrumental facilities and support. B. Sarangi thanks the
Department of Science and Technology, Government of India, New Delhi for
awarding him an INSPIRE fellowship.<?xmltex \hack{\newline}?><?xmltex \hack{\newline}?> Edited by:
A. Kokhanovsky</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>
Aggarwal, S. G., Sarangi, B., Kumar, S., and Gupta, P. K.: A simplified
approach to calibrate condensation particle counter for aerosol number
concentration measurement, in: 8th International Conference on Advances in
Metrology (AdMet-2013) and Pre-AdMet Workshop, 20–23 February 2013, New
Delhi, India, OP-26, P100–101, 2013.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>
Baron, P. A. and Willeke, K.: Gas and particle motion, in: Aerosol
Measurement: Principles, Techniques, and Applications, edited by:
Baron, P. A. and Willeke, K., Wiley, New York, 61–97, 2001.</mixed-citation></ref>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>Buonanno, G., Dell'Isola, M., Stabile, L., and Viola, A.: Uncertainty budget
of the SMPS-APS system in the measurement of <inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn>10</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn>2.5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>
and <inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, Aerosol Sci. Tech., 43, 1130–1141, 2009.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>Geller, M., Biswas, S., and Sioutas, C.: Determination of particle effective
density in urban environments with a differential mobility analyzer and
aerosol particle mass analyzer, Aerosol Sci. Tech., 40, 709–723,
<ext-link xlink:href="http://dx.doi.org/10.1080/02786820600803925" ext-link-type="DOI">10.1080/02786820600803925</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>Gour, A. A., Singh, S. K., Tyagi, S. K., and Mandal, A.: Variation in
parameters of ambient air quality in National Capital Territory (NCT) of
Delhi (India), Atmospheric and Climate Sciences, 5, 13–22,
<ext-link xlink:href="http://dx.doi.org/10.4236/acs.2015.51002" ext-link-type="DOI">10.4236/acs.2015.51002</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>Gysel, M., Laborde, M., Olfert, J. S., Subramanian, R., and Gröhn, A. J.:
Effective density of Aquadag and fullerene soot black carbon reference
materials used for SP2 calibration, Atmos. Meas. Tech., 4, 2851–2858,
<ext-link xlink:href="http://dx.doi.org/10.5194/amt-4-2851-2011" ext-link-type="DOI">10.5194/amt-4-2851-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>
Hand, J. L. and Kreidenweis, S. M.: A new method for retrieving particle
refractive index and effective density from aerosol size distribution data,
Aerosol Sci. Tech., 36, 1012–1026, 2002.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
Hinds, W. C.: Aerosol Technology: Properties, Behavior, and Measurement of
Airborne Particles, Wiley, New York, 1999.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Horton, K. D., Ball, M. H. E., and Mitchell, J. P.: The calibration of
a California Measurements PC-2 quartz crystal cascade impactor (QCM), J.
Aerosol Sci., 23, 505–524, 1992.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>Jimenez, J. L., Bahreini, R., Cocker, D. R., Zhuang, H., Varutbangkul, V.,
Flagan, R. C., Seinfeld, J. H., O'Dowd, C. D., and Hoffmann, T.: New particle
formation from photooxidation of diiodomethane (<inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">CH</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:msub><mml:mi mathvariant="normal">I</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>), J.
Geophys. Res., 108, 4318, <ext-link xlink:href="http://dx.doi.org/10.1029/2002JD002452" ext-link-type="DOI">10.1029/2002JD002452</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Johnson, T. J., Olferta, J. S., Cabot, R., Treacy, C., Yurteri, C. U.,
Dickens, C., McAughey, J., and Symonds, J. P. R.: Steady-state measurement of
the effective particle density of cigarette smoke, J. Aerosol Sci., 75,
9–16, 2014.</mixed-citation></ref>
      <ref id="bib1.bib12"><label>12</label><mixed-citation>Kannosto, J., Virtanen, A., Lemmetty, M., Mäkelä, J. M.,
Keskinen, J., Junninen, H., Hussein, T., Aalto, P., and Kulmala, M.: Mode
resolved density of atmospheric aerosol particles, Atmos. Chem. Phys., 8,
5327–5337, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-8-5327-2008" ext-link-type="DOI">10.5194/acp-8-5327-2008</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bib13"><label>13</label><mixed-citation>Katrib, Y., Martin, S. T., Rudich, Y., Davidovits, P., Jayne, J. T., and
Worsnop, D. R.: Density changes of aerosol particles as a result of chemical
reaction, Atmos. Chem. Phys., 5, 275–291, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-5-275-2005" ext-link-type="DOI">10.5194/acp-5-275-2005</ext-link>, 2005.</mixed-citation></ref>
      <ref id="bib1.bib14"><label>14</label><mixed-citation>Kelly, W. P. and McMurry, P. H.: Measurement of particle density by inertial
classification of differential mobility analyzer–generated monodisperse
aerosols, Aerosol Sci. Tech., 17, 199–212, <ext-link xlink:href="http://dx.doi.org/10.1080/02786829208959571" ext-link-type="DOI">10.1080/02786829208959571</ext-link>,
1992.</mixed-citation></ref>
      <ref id="bib1.bib15"><label>15</label><mixed-citation>
Khlystov, A., Stanier, C., and Pandis, S. N.: An algorithm for combining
electrical mobility and aerodynamic size distributions data when measuring
ambient aerosol, Aerosol Sci. Tech., 38, 229–238, 2004.</mixed-citation></ref>
      <ref id="bib1.bib16"><label>16</label><mixed-citation>
Kim, S., Woo, K., Liu, B., and Zachariah, M.: Method of measuring charge
distribution of nanosized aerosols, J. Coll. Interface Sci., 282, 46–57,
2005.</mixed-citation></ref>
      <ref id="bib1.bib17"><label>17</label><mixed-citation>Kostenidou, E., Pathak, R. K., and Pandis, S. N.: An algorithm for the
calculation of secondary organic aerosol density combining AMS and SMPS data,
Aerosol Sci. Tech., 41, 1002–1010, <ext-link xlink:href="http://dx.doi.org/10.1080/02786820701666270" ext-link-type="DOI">10.1080/02786820701666270</ext-link>, 2007.</mixed-citation></ref>
      <ref id="bib1.bib18"><label>18</label><mixed-citation>Lee, S. Y., Widiyastuti, W., Tajima, N., Iskandar, F., and Okuyama, K.:
Measurement of the effective density of both spherical aggregated and ordered
porous aerosol particles using mobility- and mass-analyzers, Aerosol Sci.
Tech., 43, 136–144, <ext-link xlink:href="http://dx.doi.org/10.1080/02786820802530524" ext-link-type="DOI">10.1080/02786820802530524</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bib19"><label>19</label><mixed-citation>
Malloy, Q. G. J., Nakao, S., Qi, L., Austin, R., Stothers, C., Hagino, H.,
and Cocker III, D. R.: Real-time aerosol density determination utilizing
a modified scanning mobility particle sizeraerosol particle mass analyzer
system, Aerosol Sci. Tech., 43, 673–678, 2009.</mixed-citation></ref>
      <ref id="bib1.bib20"><label>20</label><mixed-citation>
Maricq, M. and Xu, N.: The effective density and fractal dimension of soot
particles from premixed flames and motor vehicle exhaust, J. Aerosol Sci.,
35, 1251–1274, 2004.</mixed-citation></ref>
      <ref id="bib1.bib21"><label>21</label><mixed-citation>
McMurry, P. H., Wang, X., Park, K., and Ehara, K.: The relationship between
mass and mobility for atmospheric particles: a new technique for measuring
particle density, Aerosol Sci. Tech., 36, 227–238, 2002.</mixed-citation></ref>
      <ref id="bib1.bib22"><label>22</label><mixed-citation>
Nakao, S., Tang, P., Tang, X., Clark, C. H., Seo, Li. Q., E., AsaAwuku, A.,
and Cocker III, D.: Density and elemental ratios of secondary organic
aerosol: application of a density prediction method, Atmos. Environ., 68,
273–277, 2013.</mixed-citation></ref>
      <ref id="bib1.bib23"><label>23</label><mixed-citation>
Olfert, J. S., Symonds, J. P. R., and Collings, N.: The effective density and
fractal dimension of particles emitted from a light-duty diesel vehicle with
a diesel oxidation catalyst, J. Aerosol Sci., 38, 69–82, 2007.</mixed-citation></ref>
      <ref id="bib1.bib24"><label>24</label><mixed-citation>Ovigneur, B., Landgraf, J., Snel, R., and Aben, I.: Retrieval of
stratospheric aerosol density profiles from SCIAMACHY limb radiance
measurements in the <inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">O</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> A-band, Atmos. Meas. Tech., 4, 2359–2373,
<ext-link xlink:href="http://dx.doi.org/10.5194/amt-4-2359-2011" ext-link-type="DOI">10.5194/amt-4-2359-2011</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bib25"><label>25</label><mixed-citation>
Quiros, D., Hu, S. H., Hu, S. S., Lee, E. S., Sardar, S., Wang, X. L.,
Olfert, J. S., Jung, H. J., Zhu, Y. F., and Huai, T.: Particle effective
density and mass during steady-state operation of GDI, PFI, and diesel
passenger cars, J. Aerosol Sci., 83, 39–54, 2015.</mixed-citation></ref>
      <ref id="bib1.bib26"><label>26</label><mixed-citation>Pitz, M., Schmid, O., Heinrich, J., Birmili, W., Maguhn, J., Zimmermann, R.,
Wichmann, H.-E., Peters, A., and Cyrys, J.: Seasonal and diurnal variation of
<inline-formula><mml:math display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">PM</mml:mi><mml:mn>2.5</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> apparent particle density in urban air in Augsburg, Germany,
Environ. Sci. Technol., 42, 5087–5093, 2008.</mixed-citation></ref>
      <ref id="bib1.bib27"><label>27</label><mixed-citation>Rissler, J., Nordin, E. Z., Eriksson, A. C., Nilsson, P. T., Frosch, M.,
Sporre, M. K., Wierzbicka, A., Svenningsson, B., Löndahl, J.,
Messing, M. E., Sjogren, S., Hemmingsen, J. G., Loft, S., Pagels, J. H., and
Swietlicki, E.: Effective density and mixing state of aerosol particles in
a near-traffic urban environment, Environ. Sci. Technol., 48, 6300–6308,
<ext-link xlink:href="http://dx.doi.org/10.1021/es5000353" ext-link-type="DOI">10.1021/es5000353</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bib28"><label>28</label><mixed-citation>
Sarangi, B., Aggarwal, S. G., and Gupta, P. K.: Estimation of uncertainty in
particle size measurement using differential mobility analyzer, 3rd National
Conference on Advances in Metrology (AdMet), 19–21 February 2014, Patiala,
Punjab, India, OP-1, P51–52, 2014.</mixed-citation></ref>
      <ref id="bib1.bib29"><label>29</label><mixed-citation>
Sarangi, B., Aggarwal, S. G., and Gupta, P. K.: A simplified approach to
calculate particle growth rate due to self-coagulation, scavenging and
condensation using SMPS measurements during a particle growth event in New
Delhi, Aerosol Air Qual. Res., 15, 166–179, 2015.</mixed-citation></ref>
      <ref id="bib1.bib30"><label>30</label><mixed-citation>
Schkolnik, G., Chand, D., Hoffer, A., Andreae, M. O., Erlick, C.,
Swietlicki, E., and Rudich, Y.: Constraining the density and complex
refractive index of elemental and organic carbon in biomass burning aerosol
using optical and chemical measurements, Atmos. Environ., 41, 1107–1118,
2007.</mixed-citation></ref>
      <ref id="bib1.bib31"><label>31</label><mixed-citation>
Schmid, O., Chand, D., Karg, E., Guyon, P., Frank, G. P., Swietlicki, E., and
Andreae, M. O.: Derivation of the density and refractive index of organic
matter and elemental carbon from closure between physical and chemical
aerosol properties, Environ. Sci. Technol., 43, 1166–1172, 2009.</mixed-citation></ref>
      <ref id="bib1.bib32"><label>32</label><mixed-citation>
Seinfeld, J. H. and Pandis, S. N.: Atmospheric Chemistry and Physics: From
Air Pollution to Climate Change, 2nd edn., John Wiley &amp; Sons, Inc., New
Jersey, 2006.</mixed-citation></ref>
      <ref id="bib1.bib33"><label>33</label><mixed-citation>
Sioutas, C., Abt, E., Wolfson, J. M., and Koutrakis, P.: Evaluation of the
measurement performance of the scanning mobility particle sizer and
aerodynamic particle sizer, Aerosol Sci. Tech., 30, 84–92, 1999.</mixed-citation></ref>
      <ref id="bib1.bib34"><label>34</label><mixed-citation>Spencer, M. T., Shields, L. G., and Prather, K. A.: Simultaneous measurement
of the effective density and chemical composition of ambient aerosol
particles, Environ. Sci. Technol., 41, 1303–1309, <ext-link xlink:href="http://dx.doi.org/10.1021/es061425+" ext-link-type="DOI">10.1021/es061425+</ext-link>,
2007.</mixed-citation></ref>
      <ref id="bib1.bib35"><label>35</label><mixed-citation>Svenningsson, B., Rissler, J., Swietlicki, E., Mircea, M., Bilde, M.,
Facchini, M. C., Decesari, S., Fuzzi, S., Zhou, J., Mønster, J., and
Rosenørn, T.: Hygroscopic growth and critical supersaturations for mixed
aerosol particles of inorganic and organic compounds of atmospheric
relevance, Atmos. Chem. Phys., 6, 1937–1952, <ext-link xlink:href="http://dx.doi.org/10.5194/acp-6-1937-2006" ext-link-type="DOI">10.5194/acp-6-1937-2006</ext-link>,
2006.</mixed-citation></ref>
      <ref id="bib1.bib36"><label>36</label><mixed-citation>
Tang, I. N. and Munkelwitz, H. R.: Water activities, densities, and
refractive-indexes of aqueous sulphates and sodium-nitrate droplets of
atmospheric importance, J. Geophys. Res., 99, 18801–18808, 1994.</mixed-citation></ref>
      <ref id="bib1.bib37"><label>37</label><mixed-citation>Virtanen, A., Ristimäki, J., Marjamäki, M., Vaaraslahti, K.,
Keskinen, J., and Lappi, M.: Effective Density of Diesel Exhaust Particles as
a Function of Size, SAE Technical Paper 2002-01-0056, Society of Automotive
Engineers 2002 World Congress, Detroit, USA, <ext-link xlink:href="http://dx.doi.org/10.4271/2002-01-0056" ext-link-type="DOI">10.4271/2002-01-0056</ext-link>, 2002.</mixed-citation></ref>
      <ref id="bib1.bib38"><label>38</label><mixed-citation>
Wiedensohler, A.: An approximation of the bipolar charge distribution for
particles in the submicron size range, J. Aerosol Sci., 19, 387–389, 1988.</mixed-citation></ref>
      <ref id="bib1.bib39"><label>39</label><mixed-citation>Yin, Z., Ye, X., Jiang, S., Tao, Y., Shi, Y., Yang, X., and Chen, J.:
Size-resolved effective density of urban aerosols in Shanghai, Atmos.
Environ., 100, 133–140, 2015.  </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib40"><label>40</label><mixed-citation>
Zelenyuk, A., Cai, Y., and Imre, D.: From agglomerates of spheres to
irregularly shaped particles: Determination of dynamic shape factors from
measurements of mobility and vacuum aerodynamic diameters, Aerosol Sci.
Technol., 40, 197–217, 2006.</mixed-citation></ref>

  </ref-list><app-group content-type="float"><app><title/>

    </app></app-group></back>
    <!--<article-title-html>Aerosol effective density measurement using scanning mobility particle sizer
and quartz crystal microbalance with the estimation of involved
uncertainty</article-title-html>
<abstract-html><p class="p">In this work, we have used a scanning mobility particle sizer (SMPS) and a
quartz crystal microbalance (QCM) to estimate the effective density of
aerosol particles. This approach is tested for aerosolized particles
generated from the solution of standard materials of known density, i.e.
ammonium sulfate (AS), ammonium nitrate (AN) and sodium chloride (SC), and
also applied for ambient measurement in New Delhi. We also discuss
uncertainty involved in the measurement. In this method, dried particles are
introduced in to a differential mobility analyser (DMA), where size
segregation is done based on particle electrical mobility. Downstream of the  DMA, the aerosol stream is subdivided into two parts. One is
sent to a condensation particle counter (CPC) to measure particle number
concentration, whereas  the other one is sent to  the QCM to measure the particle mass
concentration simultaneously. Based on particle volume derived from size
distribution data of  the SMPS and mass concentration data obtained from  the QCM, the
mean effective density (<i>ρ</i><sub>eff</sub>) with uncertainty of inorganic salt
particles (for particle count mean diameter (CMD) over a size range 10–478 nm),
i.e. AS, SC and AN, is estimated to be 1.76 ± 0.24, 2.08 ± 0.19 and 1.69 ± 0.28 g cm<sup>−3</sup>, values which are comparable with
the material density (<i>ρ</i>) values, 1.77, 2.17 and 1.72 g cm<sup>−3</sup>,
respectively. Using this technique, the percentage contribution of error in
the measurement of effective density is calculated to be in the range of 9–17 %.
Among  the individual uncertainty components, repeatability of
particle mass obtained by  the QCM,  the QCM crystal frequency, CPC counting
efficiency, and  the equivalence of CPC- and QCM-derived volume are the major
contributors to the expanded uncertainty (at <i>k</i> = 2) in comparison to other
components, e.g. diffusion correction, charge correction, etc. Effective
density for ambient particles at the beginning of the  winter period in New Delhi
was measured to be 1.28 ± 0.12 g cm<sup>−3</sup>. It was found that in
general, mid-day effective density of ambient aerosols increases with
increase in CMD of particle size measurement but particle photochemistry is
an important factor to govern this trend. It is further observed that the
CMD has good correlation with O<sub>3</sub>, SO<sub>2</sub> and ambient RH, suggesting
that possibly sulfate secondary materials have a substantial contribution in
particle effective density. This approach can be useful for real-time
measurement of effective density of both laboratory-generated and ambient
aerosol particles, which is very important for studying the physico-chemical
properties of particles.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Aggarwal, S. G., Sarangi, B., Kumar, S., and Gupta, P. K.: A simplified
approach to calibrate condensation particle counter for aerosol number
concentration measurement, in: 8th International Conference on Advances in
Metrology (AdMet-2013) and Pre-AdMet Workshop, 20–23 February 2013, New
Delhi, India, OP-26, P100–101, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Baron, P. A. and Willeke, K.: Gas and particle motion, in: Aerosol
Measurement: Principles, Techniques, and Applications, edited by:
Baron, P. A. and Willeke, K., Wiley, New York, 61–97, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Buonanno, G., Dell'Isola, M., Stabile, L., and Viola, A.: Uncertainty budget
of the SMPS-APS system in the measurement of PM<sub>10</sub>, PM<sub>2.5</sub>
and PM<sub>1</sub>, Aerosol Sci. Tech., 43, 1130–1141, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Geller, M., Biswas, S., and Sioutas, C.: Determination of particle effective
density in urban environments with a differential mobility analyzer and
aerosol particle mass analyzer, Aerosol Sci. Tech., 40, 709–723,
<a href="http://dx.doi.org/10.1080/02786820600803925" target="_blank">doi:10.1080/02786820600803925</a>, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Gour, A. A., Singh, S. K., Tyagi, S. K., and Mandal, A.: Variation in
parameters of ambient air quality in National Capital Territory (NCT) of
Delhi (India), Atmospheric and Climate Sciences, 5, 13–22,
<a href="http://dx.doi.org/10.4236/acs.2015.51002" target="_blank">doi:10.4236/acs.2015.51002</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Gysel, M., Laborde, M., Olfert, J. S., Subramanian, R., and Gröhn, A. J.:
Effective density of Aquadag and fullerene soot black carbon reference
materials used for SP2 calibration, Atmos. Meas. Tech., 4, 2851–2858,
<a href="http://dx.doi.org/10.5194/amt-4-2851-2011" target="_blank">doi:10.5194/amt-4-2851-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
Hand, J. L. and Kreidenweis, S. M.: A new method for retrieving particle
refractive index and effective density from aerosol size distribution data,
Aerosol Sci. Tech., 36, 1012–1026, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Hinds, W. C.: Aerosol Technology: Properties, Behavior, and Measurement of
Airborne Particles, Wiley, New York, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Horton, K. D., Ball, M. H. E., and Mitchell, J. P.: The calibration of
a California Measurements PC-2 quartz crystal cascade impactor (QCM), J.
Aerosol Sci., 23, 505–524, 1992.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Jimenez, J. L., Bahreini, R., Cocker, D. R., Zhuang, H., Varutbangkul, V.,
Flagan, R. C., Seinfeld, J. H., O'Dowd, C. D., and Hoffmann, T.: New particle
formation from photooxidation of diiodomethane (CH<sub>2</sub>I<sub>2</sub>), J.
Geophys. Res., 108, 4318, <a href="http://dx.doi.org/10.1029/2002JD002452" target="_blank">doi:10.1029/2002JD002452</a>, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Johnson, T. J., Olferta, J. S., Cabot, R., Treacy, C., Yurteri, C. U.,
Dickens, C., McAughey, J., and Symonds, J. P. R.: Steady-state measurement of
the effective particle density of cigarette smoke, J. Aerosol Sci., 75,
9–16, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>12</label><mixed-citation>
Kannosto, J., Virtanen, A., Lemmetty, M., Mäkelä, J. M.,
Keskinen, J., Junninen, H., Hussein, T., Aalto, P., and Kulmala, M.: Mode
resolved density of atmospheric aerosol particles, Atmos. Chem. Phys., 8,
5327–5337, <a href="http://dx.doi.org/10.5194/acp-8-5327-2008" target="_blank">doi:10.5194/acp-8-5327-2008</a>, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>13</label><mixed-citation>
Katrib, Y., Martin, S. T., Rudich, Y., Davidovits, P., Jayne, J. T., and
Worsnop, D. R.: Density changes of aerosol particles as a result of chemical
reaction, Atmos. Chem. Phys., 5, 275–291, <a href="http://dx.doi.org/10.5194/acp-5-275-2005" target="_blank">doi:10.5194/acp-5-275-2005</a>, 2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>14</label><mixed-citation>
Kelly, W. P. and McMurry, P. H.: Measurement of particle density by inertial
classification of differential mobility analyzer–generated monodisperse
aerosols, Aerosol Sci. Tech., 17, 199–212, <a href="http://dx.doi.org/10.1080/02786829208959571" target="_blank">doi:10.1080/02786829208959571</a>,
1992.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>15</label><mixed-citation>
Khlystov, A., Stanier, C., and Pandis, S. N.: An algorithm for combining
electrical mobility and aerodynamic size distributions data when measuring
ambient aerosol, Aerosol Sci. Tech., 38, 229–238, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>16</label><mixed-citation>
Kim, S., Woo, K., Liu, B., and Zachariah, M.: Method of measuring charge
distribution of nanosized aerosols, J. Coll. Interface Sci., 282, 46–57,
2005.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>17</label><mixed-citation>
Kostenidou, E., Pathak, R. K., and Pandis, S. N.: An algorithm for the
calculation of secondary organic aerosol density combining AMS and SMPS data,
Aerosol Sci. Tech., 41, 1002–1010, <a href="http://dx.doi.org/10.1080/02786820701666270" target="_blank">doi:10.1080/02786820701666270</a>, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>18</label><mixed-citation>
Lee, S. Y., Widiyastuti, W., Tajima, N., Iskandar, F., and Okuyama, K.:
Measurement of the effective density of both spherical aggregated and ordered
porous aerosol particles using mobility- and mass-analyzers, Aerosol Sci.
Tech., 43, 136–144, <a href="http://dx.doi.org/10.1080/02786820802530524" target="_blank">doi:10.1080/02786820802530524</a>, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>19</label><mixed-citation>
Malloy, Q. G. J., Nakao, S., Qi, L., Austin, R., Stothers, C., Hagino, H.,
and Cocker III, D. R.: Real-time aerosol density determination utilizing
a modified scanning mobility particle sizeraerosol particle mass analyzer
system, Aerosol Sci. Tech., 43, 673–678, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>20</label><mixed-citation>
Maricq, M. and Xu, N.: The effective density and fractal dimension of soot
particles from premixed flames and motor vehicle exhaust, J. Aerosol Sci.,
35, 1251–1274, 2004.
</mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>21</label><mixed-citation>
McMurry, P. H., Wang, X., Park, K., and Ehara, K.: The relationship between
mass and mobility for atmospheric particles: a new technique for measuring
particle density, Aerosol Sci. Tech., 36, 227–238, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>22</label><mixed-citation>
Nakao, S., Tang, P., Tang, X., Clark, C. H., Seo, Li. Q., E., AsaAwuku, A.,
and Cocker III, D.: Density and elemental ratios of secondary organic
aerosol: application of a density prediction method, Atmos. Environ., 68,
273–277, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>23</label><mixed-citation>
Olfert, J. S., Symonds, J. P. R., and Collings, N.: The effective density and
fractal dimension of particles emitted from a light-duty diesel vehicle with
a diesel oxidation catalyst, J. Aerosol Sci., 38, 69–82, 2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>24</label><mixed-citation>
Ovigneur, B., Landgraf, J., Snel, R., and Aben, I.: Retrieval of
stratospheric aerosol density profiles from SCIAMACHY limb radiance
measurements in the O<sub>2</sub> A-band, Atmos. Meas. Tech., 4, 2359–2373,
<a href="http://dx.doi.org/10.5194/amt-4-2359-2011" target="_blank">doi:10.5194/amt-4-2359-2011</a>, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>25</label><mixed-citation>
Quiros, D., Hu, S. H., Hu, S. S., Lee, E. S., Sardar, S., Wang, X. L.,
Olfert, J. S., Jung, H. J., Zhu, Y. F., and Huai, T.: Particle effective
density and mass during steady-state operation of GDI, PFI, and diesel
passenger cars, J. Aerosol Sci., 83, 39–54, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>26</label><mixed-citation>
Pitz, M., Schmid, O., Heinrich, J., Birmili, W., Maguhn, J., Zimmermann, R.,
Wichmann, H.-E., Peters, A., and Cyrys, J.: Seasonal and diurnal variation of
PM<sub>2.5</sub> apparent particle density in urban air in Augsburg, Germany,
Environ. Sci. Technol., 42, 5087–5093, 2008.
</mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>27</label><mixed-citation>
Rissler, J., Nordin, E. Z., Eriksson, A. C., Nilsson, P. T., Frosch, M.,
Sporre, M. K., Wierzbicka, A., Svenningsson, B., Löndahl, J.,
Messing, M. E., Sjogren, S., Hemmingsen, J. G., Loft, S., Pagels, J. H., and
Swietlicki, E.: Effective density and mixing state of aerosol particles in
a near-traffic urban environment, Environ. Sci. Technol., 48, 6300–6308,
<a href="http://dx.doi.org/10.1021/es5000353" target="_blank">doi:10.1021/es5000353</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>28</label><mixed-citation>
Sarangi, B., Aggarwal, S. G., and Gupta, P. K.: Estimation of uncertainty in
particle size measurement using differential mobility analyzer, 3rd National
Conference on Advances in Metrology (AdMet), 19–21 February 2014, Patiala,
Punjab, India, OP-1, P51–52, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>29</label><mixed-citation>
Sarangi, B., Aggarwal, S. G., and Gupta, P. K.: A simplified approach to
calculate particle growth rate due to self-coagulation, scavenging and
condensation using SMPS measurements during a particle growth event in New
Delhi, Aerosol Air Qual. Res., 15, 166–179, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>30</label><mixed-citation>
Schkolnik, G., Chand, D., Hoffer, A., Andreae, M. O., Erlick, C.,
Swietlicki, E., and Rudich, Y.: Constraining the density and complex
refractive index of elemental and organic carbon in biomass burning aerosol
using optical and chemical measurements, Atmos. Environ., 41, 1107–1118,
2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>31</label><mixed-citation>
Schmid, O., Chand, D., Karg, E., Guyon, P., Frank, G. P., Swietlicki, E., and
Andreae, M. O.: Derivation of the density and refractive index of organic
matter and elemental carbon from closure between physical and chemical
aerosol properties, Environ. Sci. Technol., 43, 1166–1172, 2009.
</mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>32</label><mixed-citation>
Seinfeld, J. H. and Pandis, S. N.: Atmospheric Chemistry and Physics: From
Air Pollution to Climate Change, 2nd edn., John Wiley &amp; Sons, Inc., New
Jersey, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>33</label><mixed-citation>
Sioutas, C., Abt, E., Wolfson, J. M., and Koutrakis, P.: Evaluation of the
measurement performance of the scanning mobility particle sizer and
aerodynamic particle sizer, Aerosol Sci. Tech., 30, 84–92, 1999.
</mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>34</label><mixed-citation>
Spencer, M. T., Shields, L. G., and Prather, K. A.: Simultaneous measurement
of the effective density and chemical composition of ambient aerosol
particles, Environ. Sci. Technol., 41, 1303–1309, <a href="http://dx.doi.org/10.1021/es061425+" target="_blank">doi:10.1021/es061425+</a>,
2007.
</mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>35</label><mixed-citation>
Svenningsson, B., Rissler, J., Swietlicki, E., Mircea, M., Bilde, M.,
Facchini, M. C., Decesari, S., Fuzzi, S., Zhou, J., Mønster, J., and
Rosenørn, T.: Hygroscopic growth and critical supersaturations for mixed
aerosol particles of inorganic and organic compounds of atmospheric
relevance, Atmos. Chem. Phys., 6, 1937–1952, <a href="http://dx.doi.org/10.5194/acp-6-1937-2006" target="_blank">doi:10.5194/acp-6-1937-2006</a>,
2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>36</label><mixed-citation>
Tang, I. N. and Munkelwitz, H. R.: Water activities, densities, and
refractive-indexes of aqueous sulphates and sodium-nitrate droplets of
atmospheric importance, J. Geophys. Res., 99, 18801–18808, 1994.
</mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>37</label><mixed-citation>
Virtanen, A., Ristimäki, J., Marjamäki, M., Vaaraslahti, K.,
Keskinen, J., and Lappi, M.: Effective Density of Diesel Exhaust Particles as
a Function of Size, SAE Technical Paper 2002-01-0056, Society of Automotive
Engineers 2002 World Congress, Detroit, USA, <a href="http://dx.doi.org/10.4271/2002-01-0056" target="_blank">doi:10.4271/2002-01-0056</a>, 2002.
</mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>38</label><mixed-citation>
Wiedensohler, A.: An approximation of the bipolar charge distribution for
particles in the submicron size range, J. Aerosol Sci., 19, 387–389, 1988.
</mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>39</label><mixed-citation>
Yin, Z., Ye, X., Jiang, S., Tao, Y., Shi, Y., Yang, X., and Chen, J.:
Size-resolved effective density of urban aerosols in Shanghai, Atmos.
Environ., 100, 133–140, 2015. 
</mixed-citation></ref-html>
<ref-html id="bib1.bib40"><label>40</label><mixed-citation>
Zelenyuk, A., Cai, Y., and Imre, D.: From agglomerates of spheres to
irregularly shaped particles: Determination of dynamic shape factors from
measurements of mobility and vacuum aerodynamic diameters, Aerosol Sci.
Technol., 40, 197–217, 2006.
</mixed-citation></ref-html>--></article>