<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" dtd-version="3.0">
  <front>
    <journal-meta>
<journal-id journal-id-type="publisher">AMT</journal-id>
<journal-title-group>
<journal-title>Atmospheric Measurement Techniques</journal-title>
<abbrev-journal-title abbrev-type="publisher">AMT</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">Atmos. Meas. Tech.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">1867-8548</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>

    <article-meta>
      <article-id pub-id-type="doi">10.5194/amt-9-955-2016</article-id><title-group><article-title>Imager-to-radiometer in-flight cross calibration: RSP radiometric comparison
with airborne and satellite sensors</article-title>
      </title-group><?xmltex \runningtitle{Imager-to-radiometer in-flight cross calibration}?><?xmltex \runningauthor{J.~McCorkel et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>McCorkel</surname><given-names>Joel</given-names></name>
          <email>joel.mccorkel@nasa.gov</email>
        <ext-link>https://orcid.org/0000-0003-2853-2036</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Cairns</surname><given-names>Brian</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2 aff3">
          <name><surname>Wasilewski</surname><given-names>Andrzej</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>NASA Goddard Space Flight Center, Greenbelt, MD, USA</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>NASA Goddard Institute for Space Studies, New York, NY, USA</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Trinovim LLC, New York, NY, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Joel McCorkel (joel.mccorkel@nasa.gov)</corresp></author-notes><pub-date><day>8</day><month>March</month><year>2016</year></pub-date>
      
      <volume>9</volume>
      <issue>3</issue>
      <fpage>955</fpage><lpage>962</lpage>
      <history>
        <date date-type="received"><day>9</day><month>June</month><year>2015</year></date>
           <date date-type="rev-request"><day>7</day><month>October</month><year>2015</year></date>
           <date date-type="rev-recd"><day>22</day><month>February</month><year>2016</year></date>
           <date date-type="accepted"><day>24</day><month>February</month><year>2016</year></date>
      </history>
      <permissions>
<license license-type="open-access">
<license-p>This work is licensed under a Creative Commons Attribution 3.0 Unported License. To view a copy of this license, visit <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/3.0/">http://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions><self-uri xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016.html">This article is available from https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016.html</self-uri>
<self-uri xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016.pdf">The full text article is available as a PDF file from https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016.pdf</self-uri>


      <abstract>
    <p>This work develops a method to compare the radiometric calibration between a
radiometer and imagers hosted on aircraft and satellites. The radiometer is
the airborne Research Scanning Polarimeter (RSP), which takes multi-angle,
photo-polarimetric measurements in several spectral channels. The RSP
measurements used in this work were coincident with measurements made by the
Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the
same aircraft. These airborne measurements were also coincident with an
overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the
RSP and OLI radiance measurements to AVIRIS since the spectral response of
the multispectral instruments can be used to synthesize a spectrally
equivalent signal from the imaging spectrometer data. We then explore a
method that uses AVIRIS as a transfer between RSP and OLI to show that
radiometric traceability of a satellite-based imager can be used to calibrate
a radiometer despite differences in spectral channel sensitivities. This
calibration transfer shows agreement within the uncertainty of both the
various instruments for most spectral channels.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <title>Introduction</title>
      <p>Remote-sensing instruments used for Earth observation are typically
characterized over their spectral, spatial, radiometric, polarimetric, and
operating sensitivities before; during; and, in the case of airborne sensors,
after science measurements have been taken. However, one way to reduce the
cost of satellite sensors is to forgo the use of onboard calibration devices
to reduce the complexity, mass, and platform requirements. Another way to
reduce cost is to be hosted by another payload, but typical requirements for
such a partnership prevent orbital maneuvers required by some onboard
calibration methods, namely lunar measurements. The NASA Earth Venture –
Instrument class missions are intended to have low-to-moderate cost caps
and therefore fall within the paradigm of required cost savings that may
preclude onboard calibrators and their use due to host spacecraft
requirements, or the calibrator cost itself. Cost-saving strategies such as
these put science results at risk of being contaminated by calibration
issues such as transfer-to-orbit changes and sensor degradation while in
operation. To mitigate this risk, vicarious calibration techniques can be
used to transfer radiometric traceability from one sensor to another and
track degradation over time.</p>
      <p>One type of vicarious calibration that does not impose requirements on the
sensor or its host spacecraft is cross calibration with other sensors. This
is common practice for researchers who need to apply a calibration to their
sensor or validate that the current characterization of the sensor is
stable. These activities also have the ability to identify systematic biases
between sensors (Doelling et al., 2015) and promote discussion of advancing
instrument design. For sensors operating in the solar reflective spectrum,
most of these studies focus on comparing results of imagers; however,
radiometers such as polarimeters can also benefit from these cost-saving
techniques by leveraging calibration traceability from other sensors through
intercalibration.</p>
      <p>In this work we will compare the radiometric calibration of three sensors:
Research Scanning Polarimeter (RSP), Airborne Visible/Infrared Imaging
Spectrometer (AVIRIS), and Landsat 8 Operational Land Imager (OLI). RSP is an
airborne radiometer that scans in the along-track direction and measures the
total radiance together with the Stokes parameters <inline-formula><mml:math display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> in nine narrow
spectral channels spread across the solar reflective spectrum (Cairns et al.,
1999). As described by its name, AVIRIS is an airborne imaging spectrometer
that operates in the 365–2495 nm spectral range with spectral channels of
approximately 10 nm bandwidth and 10 nm sampling. To form an image, AVIRIS
scans in the cross-track direction at 12 Hz over a full field of view of
34<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> with 677 spatial samples. RSP and AVIRIS were hosted on the ER-2
aircraft in spring 2014 for the HyspIRI Preparatory Airborne campaign where
the instruments took simultaneous measurements. One particular flight line on
31 March 2014 was contemporaneous with an OLI overpass. OLI is a push broom
imager with a 185 km swath width measuring in nine solar reflective spectral
channels, of which one is panchromatic across the visible to near infrared.
The multispectral channels have 30 m ground sample distance, and the
panchromatic channel has 15 m sampling but is not used in this work. This
work uses the coincident data sets of these three sensors to study methods
for characterizing a radiometer using cross calibration to imagers.</p>
      <p>Specifically, we want to transfer the calibration from Landsat 8 OLI to
AVIRIS and, finally, to RSP. The calibration of OLI is well understood and
was carefully characterized prior to launch. It is closely monitored with
onboard calibrators and many vicarious techniques (Knight et al., 2014;
Czapla-Myers et al., 2015; Morfitt et al., 2015). AVIRIS is also carefully
characterized, but resources for airborne instruments and associated
calibration and accuracy rarely approach that of a Landsat-class sensor.
Therefore, the goal here is to link the radiometric calibration of RSP to
OLI using AVIRIS as a transfer. This can be done under the assumption that
the AVIRIS calibration accuracy is slowly varying over the spectrum, allowing
the calculation of a smooth transfer curve to derive OLI-based radiance from
AVIRIS data. This spectral analysis was done to ensure that differences in
the spectral sensitivities of the sensors are accounted for properly in the
comparisons of their measurements. Both OLI and AVIRIS have higher spatial
resolution than RSP, allowing for the proper account of differences in the
spatial response of the measurements of each sensor.</p>
</sec>
<sec id="Ch1.S2">
  <title>Method</title>
      <p>The spectral responses of Landsat 8 OLI and RSP are shown in Fig. 1a. There
are several spectral channels where there is some overlap between the two
sensors, viz., OLI-2 and RSP-2, OLI-3 and RSP-3, OLI-5 and RSP-5, OLI-6 and
RSP-7, and OLI-7 and RSP-9. However, the differences in channel centers and
bandwidths mean that there are non-negligible differences in measurements of
the scene below obtained by the RSP and OLI. Radiometric calibration can
still be transferred between OLI and RSP if the scene used for comparison is
well understood, either with additional measurements or using a known test
site. This work will use spectral knowledge provided by AVIRIS, which was
hosted on the ER-2 aircraft at the same time as RSP. The ability to
synthesize the RSP spectral channels using a weighted sum of AVIRIS channels
is shown in Fig. 1b, where channel centers and bandwidths are matched to
better than 1 %. Another method to retrieve spectral information is to
use desert test sites known as pseudo-invariant calibration sites (PICSs) that
are commonly used for intercalibration of space-based sensors operating in the
solar reflective spectral region. Many of these PICS are in the Sahara
and are measured at least once per day from near-polar orbits. The
primary advantage of the PICS methodology is that frequent comparisons
provide excellent data for trending and reducing noise in results. However,
the PICS methodology largely relies on empirical fits that still need further
work to establish robust radiometric traceability. The optimal calibration
solution is to use both vicarious methodologies: coincident underflights to
establish absolute radiometric calibration and PICS-like methods for
radiometric trending.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><caption><p><bold>(a)</bold> Spectral responses of Landsat 8 OLI as a solid red line
and RSP as a dashed blue line. <bold>(b)</bold> AVIRIS spectral channels are
approximately 10 nm wide and Gaussian-shaped with 10 nm spacing from
365 to 2495 nm, and weighted sums (dashed lines) have been used to match the
RSP spectral channels (solid lines).</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f01.png"/>

      </fig>

      <p>The sensors studied in this work operate at various spatial resolutions: RSP
is a multichannel scanning radiometer that samples in the along-track
direction with approximately 220 m instantaneous field of view for the nadir
measurements used in this work; OLI is a push broom imager with a 30 m ground
sample distance; AVIRIS is a spectroradiometer that scans in the cross-track
direction to form an image with a 16.1 m pixel size at nadir. It makes sense
to calculate signals from OLI and AVIRIS that are spatially equivalent to
RSP, since RSP has the largest footprint of the three sensors. This is done
by modeling the spatial response of RSP and convolving it with spatially
gridded OLI and AVIRIS data.</p>
      <p>The spatial response of RSP is circular with 14 mrad extent and has 14 mrad
of drag smear in the scan direction. The resulting spatial response of a
measurement is estimated to have a triangular distribution of 28 in the
scan direction and 14 mrad in the cross-track direction. The response shape
is rotated to match the heading of the aircraft at the time of measurement,
and its center is assigned a location according to the associated geolocation
information. A spatial response mask, shown in Fig. 2, is calculated at the
resolution of the image we are comparing to, either OLI or AVIRIS. This
calculation also depends on the distance between the RSP and the ground,
which is shown in Fig. 3 for the measurements used in this work.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><caption><p>Modeled spatial response of a nadir RSP measurement where the long
direction is along track (scan direction).</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f02.png"/>

      </fig>

      <p>There are 152 Earth-view samples collected during each RSP scan. The sample
closest to nadir-view geometry within each scan is selected for comparison
with the other sensors. The geographic location of each RSP measurement,
provided in the L1 data product, is used to find the corresponding
measurement within the AVIRIS and OLI data. A 60 <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 60 pixel area
centered on the AVIRIS or OLI pixel that best matches the RSP nadir
measurement location is extracted from the AVIRIS and OLI imagery for each
RSP measurement. The apodization mask that emulates the RSP spatial response
is multiplied by each subset extracted from the AVIRIS and OLI imagery.
Summing this product and dividing by the sum of the apodization mask provides
AVIRIS and OLI signals that have equivalent spatial response to RSP with
nearly the same viewing geometry.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><caption><p>Although the ER-2 holds absolute altitude within tens of meters,
the size of the RSP footprint will depend on the sensor's height above
ground level, which varies by almost a kilometer in the data set used here.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f03.png"/>

      </fig>

      <p>Temporal, spectral, and spatial parameters have been discussed and accounted
for in our calibration comparison of radiometric response. In Table 1 we
provide more detail regarding the uncertainties in the knowledge of offset,
radiometric gain, and nonlinearity of response for the RSP. The dark values
for the RSP are determined using nine views of a dark reference after a
domain controller (dc) restore that resets an integrator. The consequent uncertainties in the
determination of this dark level caused by noise are given in digital numbers
(DN) and also normalized radiance units in Table 1 in the rows labeled
<inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>dark</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. The RSP also has a pre-dc restore measurement that is
used to track drifts in the offset within a scan. The scan period is
0.8409 s, and the amount of drift is currently negligible with a worst case
drift of less than 0.05 DN and typical drifts of 0.005 DN. The dark
reference is located 180<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> from the nadir view and should therefore be
fairly immune to contamination by scene radiance. However, there is always
some leakage/scattering of scene light into the dark reference, and near-field
observations of a large aperture integrating sphere provide a good upper
bound on such contamination, since the solid angle subtended by the sphere is
large. Scattering off blackened and baffled surfaces is largest at the
shortest wavelengths, which is why the contamination of the dark reference is
largest at 410 nm. Even so it is only 0.08 % of the scene radiance,
causing negligible radiometric errors. The radiometric uncertainty given in
Table 1 has two sources. The first is the transfer uncertainty from the NIST
standard source to the secondary standard source that is used for
calibration: in this case a sphere (e.g.,
<uri>http://cf.gsfc.nasa.gov/docs/Error/750SlickXferUncert.html</uri>). The second
source of uncertainty is the variation in the calibration, or gain,
coefficient when multiple lamp levels are being fitted. These two sources of
uncertainty are considered to be independent, and they are therefore added in
quadrature (sum of squares). An additional uncertainty at 1880 nm is
absorption by water vapor in the path through the sphere, which yields an
additional uncertainty of 7 % and is the primary source of uncertainty at
that wavelength. Repeatability of the determination of the calibration
coefficients (<inline-formula><mml:math display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 1 % except for the 1880 nm band) is compatible
with the uncertainties given here and likely changes in instrument
performance after multiple ER-2 flights. Nonlinearity in the RSP detector
responses can be assessed by fitting an equation of the form
RSP<inline-formula><mml:math display="inline"><mml:msub><mml:mi/><mml:mtext>intensity</mml:mtext></mml:msub></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>=</mml:mo></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mi>a</mml:mi></mml:math></inline-formula> <inline-formula><mml:math display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> Lamp<inline-formula><mml:math display="inline"><mml:mrow><mml:msubsup><mml:mi/><mml:mtext>Radiance</mml:mtext><mml:mi>b</mml:mi></mml:msubsup></mml:mrow></mml:math></inline-formula> to data from calibrations at multiple radiance levels.
Deviations of the fitting parameter, b, from unity indicate the level of
nonlinearity. The last row in Table 1 shows that nonlinearity in the
RSP response is less than 0.5 % in all bands except the 1880 nm band.
Since this band is sensitive to small variations in relative humidity during
the course of a calibration, the larger nonlinearity in that case is likely
to be caused by environmental variations. Given the uncertainty in the
calibrated radiances, it is not possible to reject the hypothesis that the RSP
sensor response is linear. The RSP sensor used in this study was
radiometrically calibrated at NASA Ames Research Center, looking down into a
30 in. spherical integrating sphere at seven different lamp levels (cf.
Cairns et al., 1999). In Sect. 3 we show a comparison between RSP and AVIRIS
over a wide dynamic range that demonstrates that the primary difference
between the sensors is the radiometric gain. The next section presents
assessment and results of using data that have been put on a common spatial
scale to compare radiometric gain among the sensors.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1" specific-use="star"><caption><p>Uncertainties in dark reference determination, contamination of
dark reference by scene radiance, radiometric gain and nonlinearity in
response.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="10">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:colspec colnum="9" colname="col9" align="right"/>
     <oasis:colspec colnum="10" colname="col10" align="right"/>
     <oasis:tbody>
       <oasis:row>  
         <oasis:entry colname="col1">Band (nm)</oasis:entry>  
         <oasis:entry colname="col2">410</oasis:entry>  
         <oasis:entry colname="col3">470</oasis:entry>  
         <oasis:entry colname="col4">555</oasis:entry>  
         <oasis:entry colname="col5">670</oasis:entry>  
         <oasis:entry colname="col6">865</oasis:entry>  
         <oasis:entry colname="col7">960</oasis:entry>  
         <oasis:entry colname="col8">1590</oasis:entry>  
         <oasis:entry colname="col9">1880</oasis:entry>  
         <oasis:entry colname="col10">2260</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>dark</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (DN)</oasis:entry>  
         <oasis:entry colname="col2">0.22</oasis:entry>  
         <oasis:entry colname="col3">0.22</oasis:entry>  
         <oasis:entry colname="col4">0.22</oasis:entry>  
         <oasis:entry colname="col5">0.17</oasis:entry>  
         <oasis:entry colname="col6">0.23</oasis:entry>  
         <oasis:entry colname="col7">0.20</oasis:entry>  
         <oasis:entry colname="col8">0.27</oasis:entry>  
         <oasis:entry colname="col9">0.28</oasis:entry>  
         <oasis:entry colname="col10">0.27</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1"><inline-formula><mml:math display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>dark</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> (norm. rad.)</oasis:entry>  
         <oasis:entry colname="col2">1.5E-5</oasis:entry>  
         <oasis:entry colname="col3">1.2E-5</oasis:entry>  
         <oasis:entry colname="col4">1.1E-5</oasis:entry>  
         <oasis:entry colname="col5">1.0E-5</oasis:entry>  
         <oasis:entry colname="col6">0.8E-6</oasis:entry>  
         <oasis:entry colname="col7">1.0E-5</oasis:entry>  
         <oasis:entry colname="col8">1.0E-5</oasis:entry>  
         <oasis:entry colname="col9">1.0E-5</oasis:entry>  
         <oasis:entry colname="col10">1.0E-5</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Dark Cont. (%)</oasis:entry>  
         <oasis:entry colname="col2">0.08</oasis:entry>  
         <oasis:entry colname="col3">0.03</oasis:entry>  
         <oasis:entry colname="col4">0.01</oasis:entry>  
         <oasis:entry colname="col5">0.005</oasis:entry>  
         <oasis:entry colname="col6">0.005</oasis:entry>  
         <oasis:entry colname="col7">0.005</oasis:entry>  
         <oasis:entry colname="col8">0.003</oasis:entry>  
         <oasis:entry colname="col9">0.005</oasis:entry>  
         <oasis:entry colname="col10">0.005</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Radiometric</oasis:entry>  
         <oasis:entry colname="col2">1.6</oasis:entry>  
         <oasis:entry colname="col3">1.3</oasis:entry>  
         <oasis:entry colname="col4">1.2</oasis:entry>  
         <oasis:entry colname="col5">1.1</oasis:entry>  
         <oasis:entry colname="col6">0.9</oasis:entry>  
         <oasis:entry colname="col7">0.9</oasis:entry>  
         <oasis:entry colname="col8">0.8</oasis:entry>  
         <oasis:entry colname="col9">7.0</oasis:entry>  
         <oasis:entry colname="col10">2.8</oasis:entry>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Uncertainty (%)</oasis:entry>  
         <oasis:entry colname="col2"/>  
         <oasis:entry colname="col3"/>  
         <oasis:entry colname="col4"/>  
         <oasis:entry colname="col5"/>  
         <oasis:entry colname="col6"/>  
         <oasis:entry colname="col7"/>  
         <oasis:entry colname="col8"/>  
         <oasis:entry colname="col9"/>  
         <oasis:entry colname="col10"/>
       </oasis:row>
       <oasis:row>  
         <oasis:entry colname="col1">Nonlinearity<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> (%)</oasis:entry>  
         <oasis:entry colname="col2">0.3</oasis:entry>  
         <oasis:entry colname="col3">0.2</oasis:entry>  
         <oasis:entry colname="col4">0.2</oasis:entry>  
         <oasis:entry colname="col5">0.4</oasis:entry>  
         <oasis:entry colname="col6">0.4</oasis:entry>  
         <oasis:entry colname="col7">0.2</oasis:entry>  
         <oasis:entry colname="col8">0.2</oasis:entry>  
         <oasis:entry colname="col9">0.7</oasis:entry>  
         <oasis:entry colname="col10">0.5</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p><inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>*</mml:mo></mml:msup></mml:math></inline-formula> Notes: the natural log of the fitting parameter, <inline-formula><mml:math display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula>, described in the
text multiplied by 100.</p></table-wrap-foot></table-wrap>

</sec>
<sec id="Ch1.S3">
  <title>Results</title>
      <p>RSP, AVIRIS, and OLI data used in this work were downloaded from each sensor's
respective server on 1 September 2014, and red-green-blue snapshots from the
imagers are shown in Figs. 4 and 5, where the right image in Fig. 5 is a
magnification in the OLI image of the area measured by RSP and AVIRIS. The
red line in Fig. 4 shows the positions of the nadir RSP measurements, and the
associated numbers indicate the scan number for this leg. The red lines in
Fig. 5 correspond to the same locations in the OLI imagery.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><caption><p>This image shows AVIRIS data acquired 31 March 2014 during 18:13–18:17 UTC
in California near the southwestern California–Nevada border. The red
line shows the location of the center of nadir RSP measurements, where the
numbers indicate the scan number.</p></caption>
        <?xmltex \igopts{width=85.358268pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f04.png"/>

      </fig>

      <p>Ivanpah Playa is seen in the magnified image of Fig. 5 and is the long,
narrow, bright feature along the eastern edge of the image. Other flight
lines flown by the ER-2 on this campaign day measured this commonly used
radiometric calibration test site, but not at the time of the Landsat
overpass. While there was a research team taking surface reflectance and
atmospheric measurements near the center of the playa as part of AVIRIS
calibration activities, this work focuses on the intercalibration
performance between the RSP and the airborne and satellite imagers. We
therefore use coincident measurements of the three sensors: the AVIRIS and
RSP data used here were collected during 18:13–18:17 UTC, and the Landsat overpass was
at 18:16 UTC on 31 March 2014.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><caption><p>Landsat 8 OLI scene of southern Nevada captured on 31 March 2014
at 18:16 UTC is shown on the left. The ER-2 flight path and associated RSP
and AVIRIS measurements were collected along the red line during 18:13–18:17 UTC on the same day. The flight path is 24.7<inline-formula><mml:math display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> west of north with
total path length of 57.1 km. The right image is a magnified view of the
area of the flight line.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f05.png"/>

      </fig>

      <p>There are 336 discrete measurement locations along the red line that is
overlaid on Figs. 4 and 5. As described in the previous section, the
modeled spatial response of RSP is convolved with the AVIRIS and OLI imagery
to obtain signals that are spatially equivalent to the RSP spatial
response. These calculated signals are shown in Fig. 6 for the near-infrared
channel of the sensors: OLI channel 5 and RSP channel 5. The spectral
response data of RSP channel 5 was used to band-average the AVIRIS signal for
this plot. The agreement in shape and fluctuations in these lines
(correlation of 0.998) indicates high-quality geolocation of the sensors as
well as similar calibration performance. Another measure of agreement between
the sensors is the similarity of the variability in each sample as shown in
Fig. 7, although only AVIRIS and OLI can be gauged in this manner since each
RSP measurement is a single nadir value. Other spectral channel pairs show
similar agreement in shape and fluctuations, but the curves have offsets from
each other. One reason for these biases is differences in spectral channel
location and shape that mean the sensors are measuring different spectral
regions. Another culprit is radiometric calibration disagreement between the
sensors.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><caption><p>The signal of OLI, AVIRIS, and RSP along the line formed by
locations of RSP nadir measurements. The OLI and AVIRIS imagery was
spatially averaged to match the RSP footprint. The AVIRIS spectrum was
band-averaged to match RSP channel 5.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f06.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><caption><p>The percent standard deviation of each measurement along the
flight path. There about 100 AVIRIS and OLI pixels within each RSP
measurement footprint, and the variability of these pixels provides an
assessment of the land surface uniformity within the RSP footprint.
Measurements with high variability will be more sensitive to geolocation
errors among the sensors and can be screened from further processing.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f07.png"/>

      </fig>

      <p>One way to compare the radiometric signals from these sensors and alleviate
spectral response differences is to compare the multispectral sensors, RSP
and OLI, to the imaging spectrometer. The spectral response of each spectral
channel of the imagers is used to calculate the RSP- and OLI-spectrally
equivalent signals of AVIRIS data. This means that AVIRIS becomes the basis
for radiometric comparison, and results of these calculations are shown in
Fig. 8. The vertical axis is in units of percent difference from AVIRIS-based
radiance, so circles on the zero line would represent perfect agreement, and
negative values occur when AVIRIS reports a lower radiance than the sensor it
is being compared to. All points are within 5 % agreement except for
channel 1 of both sensors and the channels affected by water vapor
absorption. Causes for difference in radiance are primarily due to
disagreements in sensor characterization, but factors such as small
geolocation errors and atmospheric differences can be additional sources of
uncertainty in this comparison. However, geolocation errors are minimized by
only selecting measurements that have 3 % variability or less. This
screening process, which selected 64 of the 336 samples, selects only samples
over uniform areas of surface cover, which reduces contamination of results
caused by potential geolocation mismatch between the sensors, and atmospheric
differences are minimized by the use of coincident data sets.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8"><caption><p>The percent difference in radiance between band-averaged AVIRIS
and the multispectral sensors, RSP and OLI.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f08.png"/>

      </fig>

      <p>While agreement of RSP and OLI with AVIRIS is quite good, with only one
window channel showing a difference of greater than 5 %, we want to
derive a more direct intercalibration link between the RSP and OLI
calibration to demonstrate a method for assessing consistency between a
radiometer and an orbiting multispectral imager. One difficult aspect of this
problem is that the spectral channels of the radiometer, RSP, and the imager,
OLI, do not have identical spectral sensitivities. There are two general
methods to solve this problem: model the spectral variability of the test
site or measure it. The first has been done in other work by using in situ
measurements (Teillet et al., 2001;
McCorkel et al., 2013). The second is possible if we use an imaging
spectrometer as a transfer radiometer, such that the calibration knowledge of
OLI is applied to AVIRIS and subsequently to RSP. Except for the spectral
channels affected by water vapor, the data of both sensors in Fig. 8 follow a
similarly shaped curve, suggesting that RSP and OLI calibration behaviors are
in closer agreement with one another than with AVIRIS. The curve could be
used to create a correction to convert AVIRIS radiances to have an
OLI-equivalent radiance scale. Such a curve is shown as a ratio in Fig. 9
such that multiplying AVIRIS-measured spectral radiance by this factor will
provide a signal with radiometric traceability to OLI.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><caption><p>The ratio difference in spectral radiance between OLI and AVIRIS
is used to calculate a correction curve. The multispectral points (circles)
are interpolated to the spectral location of each AVIRIS channel (shown as
line).</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f09.png"/>

      </fig>

      <p>Creating a calibration curve for an imaging spectrometer based on a
multispectral signal may seem counterintuitive, but the prevalence of
multispectral imagers with well-understood calibration currently on orbit
means that such a method has a wide range of application. There is concern
that, since the multispectral sensors have zero information between their
channels, they can not provide calibration information to the imaging
spectrometer. However, like many things in nature, variations in imaging
spectrometer response are typically spectrally continuous rather than
displaying discrete, step-function-like changes. This is due to the
spectrally continuous nature of the characteristics of the optical
components used in the instrument such as mirrors, diffraction gratings, and
detectors. These components have reflectivities, efficiencies, and
responsivities that vary slowly with wavelength over the spectral regions
they were designed to operate over. Even an imaging spectrometer like AVIRIS
that uses four separate spectrometers to cover the full solar reflective
spectral range will show continuous behavior since discontinuities are
necessarily minimized as part of the laboratory calibration process.</p>
      <p>The OLI-calibrated AVIRIS spectral radiance is band-averaged with the RSP
spectral response and compared with RSP-measured spectral radiance. The
difference between these signals is shown in Fig. 10. Agreement is within
5 % except for the 470, 960, and 1880 nm RSP channels. The 1880 nm data
point is off the scale in Fig. 10. The 960 and 1880 nm spectral bands are
strongly affected by water vapor absorption, adding difficulty to
characterizing absolute radiometric response, even in controlled laboratory
conditions. The cause of disagreement of RSP channel 2 (470 nm) is unclear
but is possibly an artifact of the rapidly changing OLI-to-AVIRIS calibration
curve in this spectral region. Two examples of comparisons between RSP and
AVIRIS over a wide dynamic range are given in Fig. 11. When the ratio of the
spectral radiances of the two sensors is plotted against the reciprocal of
one of the sensors' spectral radiances, any influences of nonlinearity or
offset differences are emphasized. If radiometric gain is the only
difference, the data should fall on a horizontal line, while if there is an offset
difference the data will have a finite linear slope. In Fig. 11a the data
clearly show the difference in radiometric gain between AVIRIS and RSP at
410 nm that was noted previously. In Fig. 11b there is clearly a linear
trend that suggests a difference in offsets between the two sensors for the
960 nm band. However, since the dynamic range in the signals includes
variations in water vapor for this band that is used for water vapor
retrievals and the spectral responses of the synthetic RSP band and the
actual RSP band do not match perfectly, the difference in offsets may be
caused by differing in spectral responses.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10"><caption><p>Percent difference between RSP and OLI-calibrated AVIRIS.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f10.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11"><caption><p>Comparisons of RSP and AVIRIS over a wide dynamic range for best
(410 nm) and worst (960 nm) cases.</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://amt.copernicus.org/articles/9/955/2016/amt-9-955-2016-f11.png"/>

      </fig>

<?xmltex \hack{\newpage}?>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <title>Conclusions</title>
      <p>In this paper we compared the radiometric calibration of an airborne
radiometer (RSP) to that of an airborne imaging spectrometer (AVIRIS) and a
satellite imager (Landsat 8 OLI). We modeled the spatial response of RSP to
calculate spatially equivalent signals of the imagers for this cross
calibration. First we compared band-averaged AVIRIS radiance signals to the
multispectral sensors, RSP and OLI, by using each sensor's spectral
response. Most spectral channels of OLI and RSP agreed with AVIRIS to within
the combined sensor uncertainties. However, this comparison does not
directly compare RSP to OLI, and it is not straightforward to do so since
these sensors have different spectral sensitivities.</p>
      <p>Next, we investigated a method to transfer the calibration of OLI to RSP
using AVIRIS as a transfer. The AVIRIS signal was adjusted to match the OLI
radiometric calibration using a correction factor found by comparing OLI and
AVIRIS signals. The OLI-based AVIRIS continuous-spectrum radiance signal was
then band-averaged to RSP's spectral channels for comparison with the
RSP-measured signal. Except for the 470 nm channel and channels affected by
water vapor, the results were consistent with a <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>2.5 % spread in
the radiometric calibration of RSP and OLI. This is in contrast to the spread
of the RSP and OLI comparison to AVIRIS mentioned above, which was <inline-formula><mml:math display="inline"><mml:mo>±</mml:mo></mml:math></inline-formula>5 %.
This suggests that RSP and OLI are in good agreement except for a
possible small, 2.5 %, bias.</p>
      <p>Future efforts will work to close the radiometric link between RSP and OLI
presented here. This is possible with laboratory experiments to compare the
sensor calibration of RSP and the Landsat Transfer Radiometer (LXR) using
the same extended source. This would be a valuable comparison since the LXR
was used during prelaunch laboratory testing of OLI to provide radiometric
traceability to national standards – the LXR would therefore be a
laboratory surrogate for OLI (Markham et al., 1998; Butler and Barnes,
2003). Analysis of these data will use much of the same spectral analysis
presented here, and results will be directly comparable to those presented
above.</p>
      <p>The methodology developed here is scalable to a satellite-based radiometer,
such as the Aerosol Polarimetry Sensor (APS) had it successfully launched.
Also, since an APS-like radiometer will have a much larger terrestrial
footprint, more imagers are available for cross calibration due to relaxed
spatial-resolution requirements. For example the 250–1000 m spatial sampling
of MODIS and VIIRS can be used to emulate the spatial response of an
APS-like radiometer, while the cross-track swath of AVIRIS (11 km) is
sufficient to allow for the use of AVIRIS in conjunction with such imagers.
Advantages of sensors like these in addition to Landsat imagers for cross
calibration include frequent revisit period and accurate radiometric
calibration (Xiong and Barnes, 2006; Xiong et al., 2014).</p>
      <p>As science questions grow and the availability of science funding becomes
more limited, instrument concepts need to be developed that provide the most
benefit for the least amount of cost and risk. One way to reduce cost of
building an instrument is to forgo onboard calibrators and costly testing
associated with them, and rely on cross-calibration methods, such as the one
developed in this work, to use the well-understood calibration of flagship
sensors.</p>
</sec>

      
      </body>
    <back><ack><title>Acknowledgements</title><p>We would like to thank the NASA Radiation Sciences and Ocean Biology and
Biogeochemistry programs and the HySPIRI airborne preparatory program for
funding the acquisition of airborne data that is used in this paper. We would
also like to thank the NASA Climate Absolute Radiance and Refractivity
Observatory (CLARREO) Decadal Survey mission for support in advancing sensor
intercalibration techniques shown in this work. <?xmltex \hack{\newline}?><?xmltex \hack{\newline}?> Edited by: H. Worden</p></ack><ref-list>
    <title>References</title>

      <ref id="bib1.bib1"><label>1</label><mixed-citation>
Butler, J. J. and Barnes, R. A.: The use of transfer radiometers in
validating the visible to shortwave infrared calibrations of radiance sources
used by instruments in NASA's Earth Observing System,  Metrologia, 40,
S70–S77, 2003.</mixed-citation></ref>
      <ref id="bib1.bib2"><label>2</label><mixed-citation>Cairns, B., Russell, E. E., and Travis, L. D.: Research scanning
polarimeter: calibration and ground-based measurements, in: SPIE's International Symposium on Optical Science, Engineering, and Instrumentation,
International Society for Optics and Photonics,   186–196, 1999.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bib3"><label>3</label><mixed-citation>
Czapla-Myers, J., McCorkel, J., Anderson, N., Thome, K.,
Biggar, S., Helder, D., Aaron, D., Leigh, L., and Mishra, N.:
The ground-based absolute radiometric calibration of Landsat 8
OLI, Remote Sens., 7,  600–626, 2015.</mixed-citation></ref>
      <ref id="bib1.bib4"><label>4</label><mixed-citation>
Doelling, D. R., Wu, A., Xiong, X., Scarino, B. R.,
Bhatt, R., Haney, C. O., Morstad, D., and Gopalan, A.: The
Radiometric Stability and Scaling of Collection 6 Terra-and Aqua-MODIS VIS,
NIR, and SWIR Spectral Bands, IEEE Geosci. Remote Sens. Soc., 53, 4520–4535, 2015.</mixed-citation></ref>
      <ref id="bib1.bib5"><label>5</label><mixed-citation>
Knight, E. J. and Kvaran, G.: Landsat-8 operational land imager
design, characterization and performance, Remote Sens., 6,  10286–10305, 2014.</mixed-citation></ref>
      <ref id="bib1.bib6"><label>6</label><mixed-citation>
Markham, B. L., Schafer, J. S., Wood Jr., F. M., Dabney, P. W., and Barker,
J. L.: Monitoring large-aperture spherical integrating sources with a
portable radiometer during satellite instrument
calibration, Metrologia, 35, 643–648, 1998.</mixed-citation></ref>
      <ref id="bib1.bib7"><label>7</label><mixed-citation>
McCorkel, J., Thome, K., and Lockwood, R. B.: Absolute radiometric
calibration of narrow-swath imaging sensors with reference to non-coincident
wide-swath sensors, IEEE Geosci. Remote Sens. Soc., 51,  1309–1318, 2013.</mixed-citation></ref>
      <ref id="bib1.bib8"><label>8</label><mixed-citation>
Morfitt, R., Barsi, J., Levy, R., Markham, B., Micijevic, E.,
Ong, L., Scaramuzza, P., and Vanderwerff, K.: Landsat-8 Operational
Land Imager (OLI) radiometric performance on-orbit, Remote Sens., 7,
2208–2237, 2015.</mixed-citation></ref>
      <ref id="bib1.bib9"><label>9</label><mixed-citation>
Teillet, P. M., Fedosejevs, G., Gauthier, R. P., O'Neill, N. T., Thome, K.
J., Biggar, S. F., Ripley, H., and Meygret, A.: A generalized approach to the
vicarious calibration of multiple Earth observation sensors using
hyperspectral data, Remote Sens. Environ., 77, 304–327, 2001.</mixed-citation></ref>
      <ref id="bib1.bib10"><label>10</label><mixed-citation>
Xiong, X. and Barnes, W.: An overview of MODIS radiometric
calibration and characterization, Adv. Atmos. Sci., 23, 69–79, 2006.</mixed-citation></ref>
      <ref id="bib1.bib11"><label>11</label><mixed-citation>
Xiong, X., Butler, J., Chiang, K., Efremova, B., Fulbright, J., Lei, N.,
McIntire, J., Oudrari, H., Sun, J., Wang, Z., and Wu, A.: VIIRS on-orbit
calibration methodology and performance, J. Geophys. Res.-Atmos., 119,
5065–5078, 2014.</mixed-citation></ref>

  </ref-list><app-group content-type="float"><app><title/>

    </app></app-group></back>
    <!--<article-title-html>Imager-to-radiometer in-flight cross calibration: RSP radiometric comparison
with airborne and satellite sensors</article-title-html>
<abstract-html><p class="p">This work develops a method to compare the radiometric calibration between a
radiometer and imagers hosted on aircraft and satellites. The radiometer is
the airborne Research Scanning Polarimeter (RSP), which takes multi-angle,
photo-polarimetric measurements in several spectral channels. The RSP
measurements used in this work were coincident with measurements made by the
Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the
same aircraft. These airborne measurements were also coincident with an
overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the
RSP and OLI radiance measurements to AVIRIS since the spectral response of
the multispectral instruments can be used to synthesize a spectrally
equivalent signal from the imaging spectrometer data. We then explore a
method that uses AVIRIS as a transfer between RSP and OLI to show that
radiometric traceability of a satellite-based imager can be used to calibrate
a radiometer despite differences in spectral channel sensitivities. This
calibration transfer shows agreement within the uncertainty of both the
various instruments for most spectral channels.</p></abstract-html>
<ref-html id="bib1.bib1"><label>1</label><mixed-citation>
Butler, J. J. and Barnes, R. A.: The use of transfer radiometers in
validating the visible to shortwave infrared calibrations of radiance sources
used by instruments in NASA's Earth Observing System,  Metrologia, 40,
S70–S77, 2003.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>2</label><mixed-citation>
Cairns, B., Russell, E. E., and Travis, L. D.: Research scanning
polarimeter: calibration and ground-based measurements, in: SPIE's International Symposium on Optical Science, Engineering, and Instrumentation,
International Society for Optics and Photonics,   186–196, 1999.

</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>3</label><mixed-citation>
Czapla-Myers, J., McCorkel, J., Anderson, N., Thome, K.,
Biggar, S., Helder, D., Aaron, D., Leigh, L., and Mishra, N.:
The ground-based absolute radiometric calibration of Landsat 8
OLI, Remote Sens., 7,  600–626, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>4</label><mixed-citation>
Doelling, D. R., Wu, A., Xiong, X., Scarino, B. R.,
Bhatt, R., Haney, C. O., Morstad, D., and Gopalan, A.: The
Radiometric Stability and Scaling of Collection 6 Terra-and Aqua-MODIS VIS,
NIR, and SWIR Spectral Bands, IEEE Geosci. Remote Sens. Soc., 53, 4520–4535, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>5</label><mixed-citation>
Knight, E. J. and Kvaran, G.: Landsat-8 operational land imager
design, characterization and performance, Remote Sens., 6,  10286–10305, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>6</label><mixed-citation>
Markham, B. L., Schafer, J. S., Wood Jr., F. M., Dabney, P. W., and Barker,
J. L.: Monitoring large-aperture spherical integrating sources with a
portable radiometer during satellite instrument
calibration, Metrologia, 35, 643–648, 1998.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>7</label><mixed-citation>
McCorkel, J., Thome, K., and Lockwood, R. B.: Absolute radiometric
calibration of narrow-swath imaging sensors with reference to non-coincident
wide-swath sensors, IEEE Geosci. Remote Sens. Soc., 51,  1309–1318, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>8</label><mixed-citation>
Morfitt, R., Barsi, J., Levy, R., Markham, B., Micijevic, E.,
Ong, L., Scaramuzza, P., and Vanderwerff, K.: Landsat-8 Operational
Land Imager (OLI) radiometric performance on-orbit, Remote Sens., 7,
2208–2237, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>9</label><mixed-citation>
Teillet, P. M., Fedosejevs, G., Gauthier, R. P., O'Neill, N. T., Thome, K.
J., Biggar, S. F., Ripley, H., and Meygret, A.: A generalized approach to the
vicarious calibration of multiple Earth observation sensors using
hyperspectral data, Remote Sens. Environ., 77, 304–327, 2001.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>10</label><mixed-citation>
Xiong, X. and Barnes, W.: An overview of MODIS radiometric
calibration and characterization, Adv. Atmos. Sci., 23, 69–79, 2006.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>11</label><mixed-citation>
Xiong, X., Butler, J., Chiang, K., Efremova, B., Fulbright, J., Lei, N.,
McIntire, J., Oudrari, H., Sun, J., Wang, Z., and Wu, A.: VIIRS on-orbit
calibration methodology and performance, J. Geophys. Res.-Atmos., 119,
5065–5078, 2014.
</mixed-citation></ref-html>--></article>