Articles | Volume 17, issue 13
https://doi.org/10.5194/amt-17-4081-2024
https://doi.org/10.5194/amt-17-4081-2024
Research article
 | 
10 Jul 2024
Research article |  | 10 Jul 2024

Preparation of low-concentration H2 test gas mixtures in ambient air for calibration of H2 sensors

Niklas Karbach, Lisa Höhler, Peter Hoor, Heiko Bozem, Nicole Bobrowski, and Thorsten Hoffmann

Data sets

Preparation of low-concentration H2 test gas mixtures in ambient air for calibration of H2 sensors N. Karbach et al. https://doi.org/10.5281/zenodo.12685043

Download
Short summary
The system presented here can accurately generate and reproduce a stable flow of gas mixtures of known concentrations over several days using ambient air as a dilution medium. In combination with the small size and low weight of the system, this enables the calibration of hydrogen sensors in the field, reducing the influence of matrix effects on the accuracy of the sensor. The system is inexpensive to assemble and easy to maintain, which is the key to reliable measurement results.