Intercomparison of long-term ground-based measurements of total, tropospheric, and stratospheric ozone at Lauder, New Zealand
Robin Björklund
Corinne Vigouroux
Peter Effertz
Omaira E. García
Alex Geddes
James Hannigan
Koji Miyagawa
Michael Kotkamp
Bavo Langerock
Gerald Nedoluha
Ivan Ortega
Irina Petropavlovskikh
Deniz Poyraz
Richard Querel
John Robinson
Hisako Shiona
Dan Smale
Penny Smale
Roeland Van Malderen
Martine De Mazière
Long-term, 21st century ground-based ozone measurements are crucial to study the recovery of stratospheric ozone as well as the trends of tropospheric ozone. This study is performed in the context of the LOTUS (Long-term Ozone Trends and Uncertainties in the Stratosphere) and TOAR-II (Tropospheric Ozone Assessment Report, phase II) initiatives. Within LOTUS, we want to know why different trends have been observed by different ground-based measurements at Lauder. In TOAR-II, intercomparison studies among the different ground-based datasets are needed to evaluate their quality and relevance for trend studies. To achieve these goals, we perform an intercomparison study of total column ozone and its vertical distribution among the ground-based measurement instruments available at the Lauder station from 2000 to 2022, which are a Fourier transform infrared (FTIR) spectrometer, a Dobson spectrophotometer, a UV2 (ultraviolet double monochromator), a microwave radiometer (MWR), ozonesondes, and a stratospheric lidar. Because only the latter two provide high-vertical-resolution profiles, the vertical ozone distribution is validated using partial columns, defined to provide independent information: one tropospheric column and three stratospheric columns. Because FTIR provides total columns and vertical information covering all partial columns as well as high temporal sampling, the intercomparisons (bias, scatter, and drift) are analyzed using FTIR as the reference.
Very good agreement between the FTIR and Dobson (FTIR and UV2) total column ozone records is apparent in the high Pearson correlation of 0.97 (0.93), low biases of −3 % (−2 %), and 2 % (3 %) dispersions, which are within the respective systematic and random uncertainties. The small observed drifts 0.4 % (0.3 %) per decade are “non-significant” (or rather a low certainty in a 95 % confidence interval) and show good stability of the three ozone total column series at Lauder.
In the troposphere we find a small bias of −1.9 % with the ozonesondes but a larger one (+10.7 %) with Umkehr, which can be explained by the low degrees of freedom for signal (0.5) of Umkehr in the troposphere. However, no significant drift is found among the three instruments in the troposphere, which proves their relevance for trend studies within TOAR-II. The negative bias observed in total columns is confirmed by negative biases in all stratospheric columns for all instruments with respect to FTIR (between −1.2 % and −6.8 %). This, confirmed by the total column biases, points to a 2 %–3 % underestimation of the infrared spectroscopic line intensities. Nevertheless, the dispersion between FTIR and all techniques is typically within 5 % for the stratospheric partial columns, in close agreement with the given random uncertainty budgets.
We observe no significant drift in the stratosphere between ozonesondes and FTIR for all partial columns, with ozonesonde trends being less negative than in LOTUS (Godin-Beekmann et al., 2022, further referred to as the LOTUS22). The only significant drift in the lower-stratospheric columns is obtained between FTIR and Umkehr, as was already found in LOTUS22. Two significant positive drifts are observed in the middle stratosphere (2 % and 3 % per decade) with lidar and MWR, respectively, while two significant negative drifts are observed in the upper stratosphere (−3 % and −4 % per decade) with Umkehr and lidar, respectively. While remaining drifts are still present, our study explains roughly half of the differences in observed trends in LOTUS22 by the different sampling, vertical sensitivity, or time periods and gaps. In addition, the FTIR data in the present work have been improved since LOTUS22, reducing the differences in the upper-stratospheric and tropospheric trends. This shows the necessity for continuous review and improvement of the measurement and retrieval processes. This study also reflects the importance of super sites such as Lauder for cross-validating the long-term ozone measurements. Our study demonstrated that well-harmonized, optimized, well-characterized instruments that show very good agreement in terms of bias, dispersion, and correlation are capable of detecting trends that agree within their respective measurement uncertainties.
- Article
(3885 KB) - Full-text XML
- BibTeX
- EndNote
The study of ozone plays a crucial role in understanding the effects of climate change, as well as its impact on human health and plant life (see, e.g., WMO, 2022; Brasseur and Solomon, 2005). It is common to distinguish between stratospheric ozone and tropospheric ozone. Stratospheric ozone, commonly referred to as the “ozone layer”, serves as our primary defense against harmful UV radiation. The discovery of the hole in the ozone layer, which is most prominent over Antarctica in the austral spring but also present in the Arctic (Solomon, 1999; Manney et al., 2011), emphasized the need for monitoring and reducing the depletion of ozone. The Montreal Protocol of 1987 was implemented to reduce the emissions of ozone-depleting substances (ODSs), which are known catalysts for the chemical destruction of ozone. Over the past 30 or more years stratospheric ozone has been closely monitored through ground-based, in situ, and satellite observations. As a result of the decreased stratospheric chlorine levels (Jones et al., 2011), the growth of the ozone hole has been halted and there are indications of its recovery (Solomon et al., 2016). This recovery is particularly evident in the Antarctic, while in regions between 60° S–60° N, the increase in ozone may be offset by a continued decrease in the lower stratosphere (Ball et al., 2018). Similarly, in the Arctic it is currently unclear if there are any positive ozone trends since 2000 due to the larger dynamical variability complicating the observation of this ozone recovery (WMO, 2018).
Tropospheric ozone is a greenhouse gas that contributes to global warming (Hansen et al., 1997) and poses a significant threat to human health through its effects on the respiratory system (see, e.g., Kim et al., 2020). Unlike stratospheric ozone, tropospheric ozone has a relatively short atmospheric lifetime of hours to weeks (Stevenson et al., 2006). It does not have any direct emission sources; rather, it is a secondary gas formed by the interaction of sunlight with hydrocarbons and nitrogen oxides, which are emitted by various human-made sources such as vehicles, fossil fuel power plants, and industrial activities (Jacob, 2000). The combination of surface ozone, ozonesonde, and aircraft measurements with satellite measurements provides a long-term collection of data to study tropospheric ozone trends. These measurements show an increase in ozone since the 1990s in the tropics and northern midlatitudes (Gulev et al., 2021; Szopa et al., 2021).
This study is done within the context of LOTUS (Long-term Ozone Trends and Uncertainties in the Stratosphere). The current goal of LOTUS is to gain a comprehensive understanding of ozone trends, including their relationship to altitude and latitude, by thoroughly evaluating uncertainties in trend studies and considering the impact of errors related to the sampling and stability of datasets. Within LOTUS, Godin-Beekmann et al. (2022) use a regression model to obtain trends of the stratospheric ozone vertical distribution. They find significant differences in trends between the measurements at Lauder, Aotearoa / New Zealand, which is a station in the Network for the Detection of Atmospheric Composition Change (NDACC; De Mazière et al., 2018; Kurylo and Solomon, 1990). Comparisons between these instruments at Lauder have been performed such as that by McDermid et al. (1998), who look at several ozone profilers (lidar, microwave radiometer, and ozonesonde). These comparisons were done before 2000, however, so to analyze the recent differences between the ground-based measurements we look at comparisons done since 2000, such as that by Bernet et al. (2020). They only use two of the ground-based measurements (stratospheric lidar and microwave radiometer – MWR) together with the Aura Microwave Limb Sounding satellite and ERA5 reanalysis data and thus do not explain the differences for most measurements in Godin-Beekmann et al. (2022). Similarly, Steinbrecht et al. (2017) use the microwave radiometer, lidar, FTIR (Fourier transform infrared) spectroscopy, and Dobson Umkehr measurements in combination with satellite measurements to compute trends representative for the whole southern latitude band (35–60° S). There are some differences for FTIR and lidar in the lower stratosphere, but they find similar statistically significant values in the upper stratosphere where they calculate a trend of 2.5 % per decade and thus strengthen the results from Godin-Beekmann et al. (2022).
We will look at all of the ground-based measurements which were discrepant in Godin-Beekmann et al. (2022), namely the FTIR spectrometer, Umkehr measurements from the Dobson spectrophotometer, ozonesondes, and the stratospheric lidar. We will add the MWR as in Bernet et al. (2020), which was not included in Godin-Beekmann et al. (2022) because it stopped in 2016. We will also add to our analysis total column intercomparisons from FTIR, the Dobson spectrophotometer, and a UV2 (ultraviolet double monochromator). In our intercomparison study we aim to quantify the biases and potential drifts between the different measurements to analyze whether the discrepancies observed in the stratospheric trends at Lauder (Godin-Beekmann et al., 2022) could be due to the different sampling or vertical resolution of the measurements.
Tropospheric ozone intercomparisons will also be performed using FTIR, ozonesondes, and Umkehr datasets. This tropospheric work is made within the context of the HEGIFTOM focus working group (Harmonization and Evaluation of Ground Based Instruments for Free Tropospheric Ozone Measurements, http://hegiftom.meteo.be, last access: 18 November 2024) within the TOAR-II (Tropospheric Ozone Assessment Report phase II) initiative. This working group focuses in part on the need for a thorough intercomparison of tropospheric ozone measurements, where all biases and drifts of the instruments used are evaluated. This study will provide a detailed look at these biases and drifts, which will serve as a reference for future TOAR-II studies using these datasets.
First, in Sect. 2, we elaborate on the different ground-based ozone measurements. Next, in Sect. 3, we explain the intercomparison method where we select coincident measurements based on the sampling and adjust for differences in vertical resolution. Because we do not have high vertical resolution for all measurements, we divide the vertical ozone profile into four different partial columns, one in the troposphere (0.5–11 km) and three in the stratosphere (14–22, 22–29, and 29–42 km). Because FTIR provides total columns and vertical information covering all partial columns, as well as a good temporal sampling, the intercomparisons are performed using FTIR as the reference.
In Sect. 4 we discuss the obtained total and partial column biases, scatter, and drifts of all available ground-based techniques with respect to FTIR, putting them in perspective with the uncertainty budgets. We end with a summary and conclusions in Sect. 6.
Five ground-based measurement techniques which have vertical information available at the Lauder station (45° S, 170° E) are considered in this study: the Fourier transform infrared spectrometer (FTIR), the Dobson Umkehr method (Umkehr), the microwave radiometer (MWR), the stratospheric ozone lidar (lidar), and ozonesonde observations (sonde). Some of the specifications for each of these measurements are given in Table 1. Aside from these five profile measurements, we consider two total column ozone (TCO) measurements: Dobson TCO (Dobson), which is separate from the Dobson Umkehr technique, and Bentham ultraviolet double monochromator (UV2; Geddes et al., 2024). The FTIR and Umkehr techniques also provide total columns. In Table 1 we identify a group of low-vertical-resolution profiles (FTIR, MWR, and Umkehr) where profiles are derived from an inversion method by Rodgers (2000) and for which we give the degrees of freedom for signal. The second group contains vertically resolved measurements, which includes the sonde and lidar. The time series of the total ozone column for all these measurements are shown in Fig. 1. Note that for sonde, MWR, and lidar we show the integrated column of the available data, which covers only part of the total ozone profile, as we can see in Table 1; this is why the absolute value is shifted downward. The figure shows us the coverage of the observations over the full time span. This displays a more densely sampled time series for the FTIR, Umkehr, MWR, and UV2 measurements as opposed to the less frequent observations of the lidar and the ozonesonde. Additionally, we see a shorter time span for the MWR data (which stops in October 2016) and for UV2 (which starts in 2012) and a gap in the lidar data between 2012 and 2015. We consider observations made after 2000, which is the starting year used in recent studies (Godin-Beekmann et al., 2022; WMO, 2022) to study the stratospheric ozone recovery expected by the reduction of ODSs.
2.1 FTIR measurements
FTIR instruments record mid-infrared solar transmission spectra at high spectral resolution. The spectra contain the signatures of molecular rotational–vibrational transitions of numerous trace gases (including ozone) in the terrestrial atmosphere as they absorb solar radiation. The spectra are analyzed to measure the total columns as well as vertical concentration of these trace gases in the atmosphere using the pressure and temperature dependence of the absorption line shapes. For ozone, the FTIR vertical sensitivity is good from the surface to approximately 50 km (Vigouroux et al., 2008). The retrieval strategy is based on the inversion method developed by Rodgers (2000), and the details are described in Vigouroux et al. (2008). An important aspect of the method is the necessity of a priori vertical profiles of both the target gas and interfering species (species that have absorption lines in the same spectral window considered for the analysis of the target gas) as well as the a priori covariance matrices of the target gas (and interfering species). The vertical information is characterized by the averaging kernel A, defined through
which relates the retrieved state vector x to the true state and the a priori state vector xa, where ϵx contains the measurement and forward model errors. As an example, Fig. 2 shows the averaging kernel for one measurement relative to the a priori. Additionally, the figure shows the sensitivity of the retrieval, which is the sum of the rows of the averaging kernel and indicates the contribution of the measurement to the retrieval compared to the contribution of the a priori. Zero sensitivity would mean that only the a priori contributes to the retrieved profile and the retrieved profile is independent from the real profile. These a priori profiles are additionally shown in Fig. 2, which, for FTIR, is the same for every retrieval irrespective of when the spectrum is taken.
The selection of lines from the full solar spectrum (also called microwindows), the a priori information, and the spectroscopic database all influence the retrieved ozone profile, and thus their treatment requires great care and they have been harmonized within the InfraRed Working Group (IRWG; https://www2.acom.ucar.edu/irwg, last access: 18 November 2024) of the international collaboration NDACC (Vigouroux et al., 2008, 2015). The amount of vertical information that can be obtained is quantified by the degrees of freedom for signal (DOFS), which is the trace of the averaging kernel matrix. The total DOFS depend on this retrieval strategy but of course also on which gas is retrieved and the instrument with which it is observed. For the ozone measurements at Lauder, the total DOFS are typically around 4 to 4.5.
Since the ozone retrieval strategy plays a crucial rule in the information that can be obtained from the spectra, we use new retrieval strategy throughout this work, which is explained in more detail in Appendix A. Whenever we use the older FTIR strategy as laid out in Vigouroux et al. (2008), for example to compare to previous studies, this will explicitly be stated using “FTIR V08” to avoid confusion.
For each of the measurements, we need to consider the instrument uncertainties during the intercomparison study (see Table 2). These are divided into systematic uncertainties and random uncertainties, which capture the accuracy and the precision of the measurement, respectively. The sources of the FTIR random uncertainties are the measurement noise, errors in the forward model parameters, and the smoothing error due to the low vertical resolution. This smoothing error, however, is considered separate from the other errors as suggested by the NDACC IRWG. For FTIR, the biggest contribution, apart from the smoothing error, to the random uncertainty is typically from the temperature profile (Vigouroux et al., 2008; García et al., 2012). In the case of the systematic uncertainty, the largest contribution actually comes from the spectroscopic database. Specifically, the ozone line strength parameter has the biggest uncertainty in the FTIR retrievals. We set it to 3 % (Gordon et al., 2022). While the ozone infrared line intensities have been improved to better match the UV cross-sections, with an accuracy of 1 % for the more intense lines, the systematic uncertainties for the weaker lines are still set to 2 %–5 % (Gordon et al., 2022). The FTIR choice of microwindows includes both intense and weak lines, with different dependence on pressure and temperature, which ensures obtaining the desired vertical information (4–5 DOFS). As explained in more detail in García et al. (2012), the assumed uncertainty sources are propagated to an uncertainty in the retrieved profile following the technique of Rodgers (2000), which is captured by a full error covariance matrix Sx. Additionally, the smoothing error is calculated from the averaging kernel and the a priori covariance matrix Sa through
with I the unit matrix and Sa obtained from the Whole Atmosphere Community Climate Model (WACCM; Marsh et al., 2013) as an estimation for the error covariance. With this information we can assess which errors dominate at which altitudes, which we have calculated for 1 year of data at Lauder. We see that the smoothing error always has the largest contribution in the troposphere. Concerning the other random errors, the uncertainty in the temperature profile has the second-biggest contribution, followed by the measurement noise. Above 25 km, the random uncertainty is usually dominated by the temperature profile. As for the contributions to the systematic uncertainty, as mentioned above, the largest contribution comes from the spectroscopic parameters; most notably the line strength parameter (around 3 %), followed by the spectroscopic pressure and temperature broadening parameters, respectively (around 1 %–2 %). The uncertainty in the temperature profile also plays a role in the contribution to the total systematic uncertainty, starting to become more important above 25 km.
2.2 Microwave radiometer
The microwave ozone radiometer at Lauder measures the spectrum produced by a thermally excited rotational ozone transition at 110.836 GHz. Similar to the FTIR retrieval method described above, the profile retrieval makes use of the change in pressure broadening as a function of altitude with a vertical extent between approximately 20 and 50 km. The DOFS here, also computed from the trace of the averaging kernel matrix, are higher than those of FTIR at around 7. An example of the MWR averaging kernel is shown in Fig. 2. The experimental technique was described in Parrish et al. (1992), and technical details on the instrument used for this work are given in Parrish (1994).
A formal error analysis for the microwave ozone measurements was presented in Connor et al. (1995), and error estimates for Lauder were updated in Tsou et al. (2000). The net precision was determined to be 5 %–7 % between 56 and 1.3 hPa, and the accuracy is 7 %–9 %. The vertical resolution of the Lauder measurements is ∼ 6–8 km (FWHM, full-width at half-maximum) near 10 hPa. Vertical profiles are provided up to 68 km; however, retrievals in the mesosphere have somewhat degraded accuracy, precision, and vertical resolution relative to those in the stratosphere.
2.3 Dobson Umkehr and TCO
The Umkehr method of estimating the vertical profile of ozone using the Dobson ozone spectrophotometer has been performed since the early 1930s (Walshaw, 1989; Gotz et al., 1934), and the Umkehr measurements are some of the longest vertical profile records of ozone collected. The Umkehr method is performed using the “C” wavelength pair of the Dobson ozone spectrophotometer taken during zenith sky measurements at 12 nominal solar zenith angles (SZAs) across the range of 60–90°. A prism inside the Dobson breaks down the sunlight spectra and a pair of slits rejects light outside a narrow band of chosen wavelengths. The C wavelength pair consists of a “short” wavelength (centered on 311.5 nm) and a “long” wavelength (centered on 332.4 nm). In this range of wavelengths of UV light, absorption by ozone decreases with wavelength, creating differential observations between strong and non-absorbing solar spectra. The log of the ratio of measured intensities is called the N value. The N value changes between 90 and 60° SZA as the Sun rises or sets and the instrument records the so-called “Umkehr” curve that is sensitive to the vertical ozone distribution above the instrument.
The current NOAA operational Umkehr retrieval algorithm (Petropavlovskikh et al., 2005) uses the Bass and Paur (1985) absorption cross-section with its temperature dependence. The profiles are derived using the optimal estimation technique (Rodgers, 2000) that includes the a priori ozone profile from ozone climatology (McPeters and Labow, 2012), measurement error, and a priori uncertainties which define the averaging kernels and vertical resolution of retrieved profiles (see Fig. 2 for an example of averaging kernels for Umkehr). The measurements allow vertical information to be retrieved from the surface to approximately 50 km. The vertical information that we can get from the averaging kernel matrix for the typical Umkehr measurements gives DOFS of around 3.5.
The Lauder Umkehr record is homogenized by the method described in Petropavlovskikh et al. (2022) to create a coherent record for the long-term trend analysis of monthly mean anomalies. The method includes a correction to the Umkehr profiles for the stray light that is outside of the nominal band-pass of the Dobson instrument but is not completely filtered out by slits. The record is homogenized using the MERRA-2 GMI (Modern-Era Retrospective Analysis for Research Applications version 2 Global Modeling Initiative) model as a reference to minimize step changes in the record caused by a change in the optical characteristics of the instrument. Individual N values have a correction factor at each SZA as described in Petropavlovskikh et al. (2022).
A full uncertainty analysis of the Umkehr observations at Lauder is currently not available, but we can estimate the uncertainties from similar measurements at Boulder, CO, USA, using the same technique (see Table 2 for the random and systematic uncertainties used in this study). This provides us with an analysis of the measurement noise as well as the smoothing error as a function of altitude. This measurement noise is calculated from simulated MERRA-2 GMI profiles with added random noise based on the error matrix of Umkehr observations. Considering that the measurement noise is only part of the random error in the remote observations, this estimated uncertainty is an underestimation of the true random error. The smoothing error is calculated using Eq. (2) with Sa from the climatology described in Kramarova et al. (2013).
Umkehr total column ozone (from now dubbed Umkehr TCO) is integrated from the vertical profiles supplied by the Umkehr retrieval algorithm. The retrieved integrated Umkehr TCO is constrained by the algorithm to be within the measurement uncertainty of the observed TCO from the Dobson measurements. Additionally, regular TCO measurements are made with the Dobson ozone spectrophotometer (from now dubbed Dobson TCO) using the log of the ratio of solar irradiances made during either direct-Sun or zenith sky measurements made at regular nominal times (usually one near local solar noon, one in the morning, and one in the afternoon). Dobson TCO is typically derived from the A (305.5 and 325 nm) and D (317.5 and 339.9 nm) or C and D wavelength pairs, with corrections made for Rayleigh scattering and air mass (Komhyr and Evans, 2008). The use of double pairs is designed to minimize the influence from aerosol scattering and clouds. The precision of the Dobson measurement from direct-Sun observations is around 1 %, with an accuracy estimated to be around 5 % (Basher, 1985). It can be seen in Fig. 1 that the sampling of the Umkehr is reduced compared to direct Dobson TCO measurements. Therefore, for the total column comparisons with FTIR, the Dobson TCO will be preferred to the Umkehr integrated columns.
2.4 Lidar
The Lauder stratospheric ozone lidar is a differential absorption lidar (DIAL) that was installed by RIVM (Rijksinstituut voor Volksgezondheid en Milieu) and began measurements in 1994. This lidar system and first results are described in Swart et al. (1994). It relies on two different beams to extract information about the vertical ozone distribution from approximately 10 to 50 km in altitude. It uses an XeCl excimer laser for the primary 308 nm beam and a 2 m Raman cell of hydrogen gas at 1.3 bar to produce a 353 nm beam. The 308 nm light is moderately absorbed by ozone, while the 353 nm light acts as the reference beam. The time of flight from pulse emission through detection gives the vertical distribution information, and the abundance is computed from the ratio of 308 and 353 nm backscattered light signals. Over the instrument's multi-decadal lifetime, a number of intercomparisons have been staged with the NDACC traveling standard ozone lidar (e.g., Keckhut et al., 2004; Bernet et al., 2020). Currently, measurements are available up to July 2021, when the excimer laser failed. The lidar measurements are well resolved in altitude, with the resolution standardized within NDACC according to Leblanc et al. (2016). This resolution ranges from a few hundred meters at 10 km to several kilometers in the upper stratosphere at 50 km. Concerning the lidar uncertainties (see Table 2), there is a systematic uncertainty of approximately 3 %, which is mainly associated with uncertainty in the determination of the temperature-dependent absorption cross-section differential. The assumed random uncertainty for lidar, on the other hand, comes from the photon-counting noise.
2.5 Ozonesonde
Ozonesondes are small balloon-borne instruments carried by weather balloons and attached to radiosondes to measure the vertical ozone distribution from the surface to altitudes between 30 and 35 km. The ozonesondes launched in Lauder since 1986 are electrochemical concentration cell (ECC) ozonesondes. In these ozonesondes, a small gas sampling pump forces the ambient air through the cells that are filled with a neutral-buffered potassium iodide sensing solution. The principle of the ozone measurement is then based on the titration of ozone in this solution so that each O3 molecule causes (ideally) two electrons to flow in the external circuit. This measured electrical current can then be converted to ozone partial pressure by knowing the gas volume flow rate of and the temperature in the pump. At Lauder, ozonesondes from the two different ECC ozonesonde manufacturers (SPC and EnSci; switch made in May 1994) have been launched, and different sensing solution types (SST1.0 and SST0.5; changed in August 1996) have been used as well. As biases exist between the different manufacturer ozonesonde types and between different sensing solution types, the Lauder ozonesonde time series had to be corrected for such biases. Additionally, the location of the pump temperature sensor changed throughout the years, which should also be homogenized. These additional processing steps have been taken into account in the reprocessed, homogenized Lauder ozonesonde time series here, following the Ozonesonde Data Quality Assessment guidelines of Smit and Oltmans (2012). More details on the Lauder ozonesonde time series and the homogenization procedure can be found in Fig. 1, Table 1, and Appendix A of Zeng et al. (2024). The quoted overall precision and uncertainty of ozonesonde measurements are 3 %–5 % and 5 %–10 %, respectively (see WMO/GAW; Smit et al., 2021). The systematic uncertainties for the ozonesonde measurements in this study have presumably been removed thanks to the homogenization process. The random uncertainty in the measured ozone partial columns for the ozonesonde is shown in Table 2. A mean value of the uncertainties in the profile is taken to represent the uncertainty in the partial columns, which is likely an overestimation of the actual uncertainty, giving values between 4 % and 7 %.
In a worldwide ozonesonde comparison with satellite and ground‐based total column ozone and with satellite stratospheric O3 profiles, Stauffer et al. (2022) mentioned a negative ozone bias in the homogenized Lauder ozonesonde time records in more recent years. This feature might be related to the so-called “post-2013 drop-off in total ozone” identified in a number of ozonesonde stations (not Lauder) in Stauffer et al. (2022), but, as no clear cause has been determined yet, no correction strategy has been implemented in the WMO/GAW 2021 homogenization procedures applied here. While Stauffer et al. (2022) do not identify Lauder as a drop-off site, in this study we will discuss the implications of a potential 3 % post-2016 drop-off in TCO for the trend and drift values of the ozonesonde measurements. Our TCO measurements for the ozonesondes are shown in Fig. 1 where a post-2016 drop-off could be present, but it is better seen in a comparison to satellites at https://acd-ext.gsfc.nasa.gov/anonftp/acd/shadoz/nletter/stations_vs_satellites_timeseries.zip (last access: 18 November 2024).
2.6 UV2
Another TCO measurement available at Lauder is UV2 (Geddes et al., 2024), which is based on a Bentham UV spectrometer. UV2 makes alternating measurements of UV global and direct-Sun irradiance, and the direct-Sun spectra are then combined with Dobson-like slit functions and used to calculate ozone using the Dobson method. In Geddes et al. (2024), UV2 ozone was shown to closely agree with Dobson TCO, with a mean bias between them of 2.57 DU and a standard deviation of 1.15 DU. The precision of UV2 is therefore assumed to be consistent with the Dobson TCO at 1 %; the accuracy, determined by the mean daily standard deviation, is also calculated to be approximately 5 %. UV2 observations are available from 2012–2022 and throughout the day.
3.1 Partial column definition
Not all measurements share the same observation time, vertical extent, or vertical resolution. In order to perform a meaningful intercomparison between the various instruments, a consistent validation setup is necessary. For example, because the DOFS of several instruments are low, we do not have well-resolved information on the ozone concentration with altitude. Therefore, the vertical range is subdivided into altitude layers, where we measure “partial columns” of ozone. Similar to the approach in Vigouroux et al. (2008), these partial columns are defined by looking at the vertical information from the reference FTIR measurements as well as the altitude boundaries at which every other instrument measures. We disregard profiles from MWR, lidar, or ozonesonde if they stop in the middle of a partial column such that no discontinuity needs to be accounted for in the intercomparison. Ideally, the partial columns should have approximately 1 DOFS to ensure that the retrieved information comes mainly from the measurement and not from the a priori partial columns, meaning that for a total of ∼ 4.5 DOFS for the FTIR profile, we can define four altitude layers. The first layer is defined from the surface (∼ 0.5 km) to 11 km (corresponding to the mean tropopause height at Lauder; Sakai et al., 2016), the second from 14 km (the onset of most lidar observations) to 22 km, the third from 22 to 29 km, and the last from 29 to 42 km. This upper limit is chosen such that the partial column covers all lidar observations and no extrapolation is needed, which would be the case if the upper limit were chosen to be higher. This way, all FTIR observations have around 1 DOFS per partial column. From the ozone profiles we then integrate the partial columns, ending up with one tropospheric column and three stratospheric columns (from now on labeled “lower”, “middle”, and “upper” stratosphere). In the troposphere we can compare FTIR, Umkehr, and ozonesonde measurements. In the lower stratosphere we additionally have the lidar measurements. In the middle stratosphere we can compare all measurements, and in the upper stratosphere we compare FTIR, Umkehr, MWR, and lidar observations. Because of the lower average DOFS of the Umkehr measurements, the DOFS of the defined partial layers do not always reach 1: we get on average 0.5, 0.6, 0.7, and 1.1 from the troposphere up to the upper stratosphere. For MWR, we can calculate the DOFS for the partial layers from the averaging kernels as well to get average values of 1.1 in the middle stratosphere and 2.2 in the upper stratosphere.
Table 2 summarizes this division of partial columns and provides information on the DOFS and the median instrument uncertainties between 2001–2022. These uncertainties are divided into systematic uncertainties and random uncertainties (which includes the random smoothing error), which capture the accuracy and the precision of the measurement, respectively. For the remote sounding measurements, the uncertainties within the partial column reported in Table 2 are obtained from the uncertainties contained in the error covariance matrix Sx of the measurement by
where h transforms the volume mixing ratio profiles to the appropriate partial columns, having values of zero at altitudes outside the boundaries of the partial column. If a full error covariance matrix is not available, such as with the Umkehr observations, we use the available error estimates which we know as a function of altitude. These values are then used to calculate the errors for partial columns by taking a weighted average, similar to the process described above.
3.2 Re-gridding, smoothing, and prior substitution
In order to perform a comparison between two measurements we need to take into account the different vertical resolution of the instruments. The passive, remote sounding instruments (FTIR, Umkehr, MWR) have different averaging kernels as well as a priori, which are both important to relate the retrieved state to the true state, as is seen in Eq. (1). As already mentioned, we always perform the comparisons with respect to FTIR because these measurements provide total columns as well as partial columns from the surface up to 50 km. Before integrating the partial columns to be compared, we transform the vertical profiles according to the vertical resolution following Rodgers and Connor (2003). We can distinguish two cases depending on the resolution of the compared instrument.
3.2.1 First case – the compared instrument has a high vertical resolution: sonde and lidar
In the FTIR retrievals the altitude grid is discretized into fewer layers (47 for Lauder) than the high-vertical-resolution sonde and lidar measurements. To proceed, we will first re-grid the measurement of higher resolution to fit the vertical grid of FTIR. For this re-gridding we follow the approach of Langerock et al. (2015), where the “source” grid of the high-resolution observation is transformed to the FTIR grid. A transformation matrix is constructed which contains the fractions of how the FTIR grid is covered by this source grid, where the interpolation is constructed such that mass is conserved. In Fig. 3a, an example is shown of how the ozone profile changes due to the re-gridding onto a lower-resolution grid.
As already explained, the 47 FTIR layers, however, do not all provide accurate information on the ozone profile because of the limited DOFS of the instrument. In order to simulate this profile retrieval (as would hypothetically be observed by an FTIR measurement) for the higher-resolution measurement, the latter is smoothed using the FTIR averaging kernel as described in Rodgers and Connor (2003). By setting the FTIR measurement as “measurement 1” and the higher-resolution measurement as “2”, we can smooth the (by now re-gridded) profile x2 through
where represents the smoothed profile of the higher-resolution instrument, with the FTIR averaging kernel A1 using the a priori profile of FTIR . This smoothing step is represented by the blue line in Fig. 3a to see the final ozonesonde measurement that is compared to FTIR. The final step is to extract the partial ozone columns by integrating the profiles using the defined partial layers above.
3.2.2 Second case – the compared instrument also has a low vertical resolution: Umkehr and MWR
For the remote sounding measurements (MWR and Umkehr) an additional step needs to be considered. These retrievals are typically made with different a priori, which we need to account for in the intercomparison. In the case of the MWR observations, before we smooth the MWR profile using the FTIR averaging kernel, we will transform it, as described in Rodgers and Connor (2003), by substituting the FTIR prior according to
with I a unit matrix and the MWR prior. This way the MWR retrieval is adjusted for the different a priori and the profile is subsequently used in Eq. (4), instead of x2, for the intercomparison after smoothing with the FTIR averaging kernel.
In the case of Umkehr, the same transformation steps apply; however, the DOFS are lower than for FTIR so the roles are reversed. This means that the FTIR profiles are first re-gridded to the Umkehr grid (which has 16 vertical layers). Secondly, the Umkehr prior is substituted in the FTIR a priori by Eq. (5), where is now the Umkehr prior. Lastly, before calculating partial columns from the profile, the FTIR profile is smoothed using the Umkehr averaging kernel according to Eq. (4), where measurements 1 and 2 again refer to Umkehr and FTIR, respectively. Figure 3b shows the effect each of the transformation steps has on the FTIR and Umkehr profiles. Here we see that the biggest change comes from substitution of the FTIR prior in the Umkehr retrieval, which shifts the Umkehr profile closer to the FTIR profile at the maximum of the ozone number density.
3.3 Time coincidence
The observations are not taken simultaneously, so a choice has to be made in constructing pairs of observations. The construction is done by considering each separate measurement of Umkehr, MWR, lidar, or ozonesonde and finding the FTIR measurement which lies within a time window around the observing time of the other instrument, where the window itself depends on the instrument we compare to. The choice of the time windows is elaborated on in Appendix B. By choosing observation pairs as opposed to the full datasets, we automatically select the same time sampling of both instruments when calculating the bias and long-term drift. This leads to a time window of 6 h for Umkehr, ozonesondes, Dobson, and UV2; 12 h for lidar; and 3 h for MWR.
If more than one FTIR measurement falls within the time window of another observation, all these FTIR measurements are averaged. Because we do this, the random uncertainty associated with the measurements will be reduced. If there are N measurements within the comparison window, then the random error is reduced by for this particular comparison. If both measurement techniques have multiple measurements in the same day that fall within the time window (for example, one or more FTIR measurements are taken within 3 h from two different MWR measurements), then the FTIR measurements that fall in this overlap are used for comparison in both observation pairs.
4.1 Bias and dispersion analysis
Now that we have defined the validation setup to perform the intercomparison, we can analyze the time series of the various ground-based measurements compared to FTIR. The first metric for our validation between the ground-based instruments is the bias. The bias M that we will report here is the median value (where we choose the median over the mean because of its robust nature with respect to outliers) of the full time series of the relative differences:
where we consider the total or partial column (PC) of FTIR and a second measurement X. Before we use the relative differences to produce the results, we filter for outliers which fall beyond the 3σ deviation. Additionally, to analyze the precision within the intercomparison, we use the MAD (median absolute deviation), which is the median of the absolute deviations from the overall median.
Here it is seen that we always use the scaled MADs with a constant factor of 1.4826. This scaling factor makes the MAD representative as a deviation from the median, similarly as the standard deviation is to the average, in the case of a normal distribution (Rousseeuw and Croux, 1993). We are not dealing with perfect Gaussian distributions, but the factor still creates a reasonable value for the scatter. The MADs is thus similar to using the standard deviation but is more robust in the sense that it will be less affected by outliers. In order to put the bias and MADs in perspective, we will compare these to the combined systematic and random uncertainties of the two involved instruments, respectively. These combined uncertainties are calculated by
where σ can signify either the systematic or random uncertainty. However, if we are dealing with the comparison of two remote sounding instruments (Umkehr and MWR), the simple combination of Eq. (9) is not sufficient because we also need to account for the smoothing error from the retrieval. Because the averaging kernels are not unit matrices, the total combined errors will be correlated. From Rodgers and Connor (2003), we find the covariance of the difference Scomb to be
This equation includes the separate errors in the covariances SFTIR and SX as the last two terms and includes the different averaging kernels AFTIR and AX, which account for the smoothing error of both retrievals in the a priori covariance matrix Sa.
For every pair of comparisons we give the numbers of the median and scaled MADs of the partial column relative differences as well as the combined random and systematic uncertainties in Table 3. Also, the Pearson correlation coefficient between the individual time series in time coincidence (see Sect. 3.3) is shown as a measure of the measurements' agreement and their capacity to capture the ozone variability. We also give the Pearson correlation between the monthly anomalies of each time series in order to remove strong seasonality, which could drive the correlation. The anomalies are constructed by taking a relative difference of the ozone column with the mean ozone column of the same month over the full time series. The last column shows the number of observation pairs that are used for the intercomparison, indicating the reduced sample size compared to the full time series of the observations. The results in this table will be discussed in the following sections where we consider the total column and each partial column defined above separately, reporting on these biases and dispersion.
4.1.1 Total column
The correlation between the FTIR and Dobson total column anomalies shows an excellent Pearson correlation coefficient of 0.98 for individual time series in coincidences and 0.97 for the monthly anomalies. Furthermore, the bias and dispersion of −2.9 % and 2.0 %, respectively, are small and well within the combined systematic and random uncertainties, respectively (see Table 3). Because the Dobson spectrometer that gives us the TCO measurement is the same as used for the Umkehr data, we do not have an independent comparison; the Umkehr retrieval in particular is performed such that its integrated column is the same as Dobson TCO within the uncertainty. However, we still do the comparison for completeness, indeed obtaining the same bias (−2.9 %) but slightly smaller dispersion (1.7 %). We see that it is nicely in agreement with the smaller combined random uncertainty budget (2.3 % for Dobson TCO, 1.7 % Umkehr) and is therefore due to the different sampling of the Dobson and Umkehr measurements (see Fig. 1 and the number of pairs in Table 3). If we apply the Dobson TCO comparisons with the same sampling as the Umkehr, the scatter indeed decreases down to 1.8 %. These variations provide empirical proof that the random uncertainty budget of FTIR and Dobson total columns is very well estimated and indeed reaches a precision of 1.2 % and 1.0 %, respectively.
Considering the bias, a larger value of −4.5 % was found between FTIR and Brewer observations in the past at Izaña (Schneider et al., 2008). The improvement to a smaller bias in the present study is largely thanks to the change in spectroscopic input parameters of the FTIR retrieval strategy (see Sect. A2), where we now use the HITRAN2020 database, in which the ozone infrared line intensities in the FTIR retrieval spectral region have proven to be more in agreement with the UV cross-section than previous HITRAN versions (Gordon et al., 2022) that were used in the IRWG community.
Although the improvement is clear, we still obtain a slight overestimation of the FTIR columns, which is confirmed by the bias obtained with the UV2 measurements (−1.8 %), pointing to a slight residual bias between infrared and UV spectroscopies. The agreement between FTIR and UV2 is also very good, with a correlation of the monthly anomalies of 0.93 and a dispersion of 2.9 %. However, this dispersion is higher than the combined random uncertainty budget. To explain this, we compare Dobson and UV2 measurements directly to each other, which are taken within a time window of 12 h. The dispersion between the two instruments is found to be 1.9 %. This is higher than the 1 % random uncertainty of the UV2 instrument, which indicates that the random error budget of UV2 is underestimated.
4.1.2 Troposphere
In the tropospheric column between the ground (∼ 0.5 km) and 11 km, we compare the FTIR observations with both Umkehr and sonde data.
The FTIR and sonde tropospheric columns are in very good agreement, as shown by the high Pearson correlation coefficients of 0.91 and 0.78 for individual coincidences and monthly anomalies, respectively, and by the small bias of −1.9 % and the dispersion of 6.8 %, well within the combined uncertainties. A negative bias is expected due to remaining systematic bias in the infrared spectroscopy.
The situation is less favorable with the Umkehr comparisons. While the Pearson correlation with individual time series is good (0.78), it decreases down to 0.48 for the monthly anomalies. This is also seen in the much larger dispersion (17.9 %), which is larger than the random uncertainty budget. The observed bias is also large and positive (10.7 %) although still within the systematic uncertainty budget. The DOFS of the Umkehr tropospheric columns (0.5–11 km) are only 0.5, which can explain the weaker agreement there.
We give in Appendix C the effect of the a priori substitution and smoothing procedure (Sect. 3.2) on the profile comparisons. It is seen in Fig. C1 that the Umkehr profile in the troposphere is the only place where the procedure worsens the comparisons compared to direct ones. Therefore, we also give the numbers for the FTIR and Umkehr tropospheric column direct comparisons without smoothing: the bias is better at only 1.8 %. The fact that this bias between FTIR and direct Umkehr tropospheric ozone is small is interesting for use in HEGIFTOM studies at Lauder. However, the scatter stays at similar levels (18.1 %), as does the correlation: rindiv=0.82 and ranom=0.34. Because the FTIR and ozonesonde dispersion agree well within the combined random uncertainty, this large scatter between FTIR and Umkehr points to an underestimation of the Umkehr random uncertainty budget, which presently only accounts for the measurement noise.
4.1.3 Lower stratosphere
In the lower stratosphere (14–22 km) we can again compare FTIR to Umkehr and sonde data and additionally the lidar measurements which start above the tropopause. There is a strong correlation for these partial columns, between 0.93 and 0.97 for the individual time series and still between 0.79 and 0.92 for the monthly anomalies. For all comparisons we find a negative bias from −1.2 % for lidar, −3.2 % for Umkehr, and −6.8 % for sonde. Similarly as with the results for the troposphere, all these values fall within the range of the combined systematic uncertainties for the respective instruments in the intercomparisons, and the systematic bias of FTIR is confirmed. For the dispersion of the FTIR and sonde comparison, we find a value of 4.6 %, which is very comparable to the combined random uncertainty. For Umkehr we get a dispersion of 5.2 %, which is only slightly larger than the random instrument uncertainties in this partial column (4.3 %). For lidar, the dispersion (8.3 %) is significantly larger than the uncertainty (2.6 %). We should keep in mind that the time coincidence is set to 12 h between the FTIR and lidar that are measuring during day and night, respectively. Therefore, a collocation mismatch could play a larger role in this comparison.
4.1.4 Middle stratosphere
In the middle stratosphere (22–29 km) we have all five ground-based measurements available for intercomparison. We find a good correlation between the measured partial columns, between 0.78 and 0.86 for individual time series but decreasing to 0.64 and 0.83 for the monthly anomalies, with the worst correlation being with Umkehr. For all measurements we find a negative bias of around −5 % to −7 % with respect to FTIR. The bias found with MWR falls within the combined systematic uncertainties in this column. However, with respect to the ozonesonde, Umkehr, and lidar data, the bias is greater than the combined measurement uncertainties. A similar bias of −7 % was found in García et al. (2012) between FTIR and sonde at Izaña in this partial column, meaning that the improvement of the infrared spectroscopy (Gordon et al., 2022) since this study, which used a previous version of HITRAN, is not sufficient to reduce the FTIR systematic bias in the middle stratosphere. Apart from the largest contribution of FTIR systematic bias, which is still the spectroscopy (3.1 %), the uncertainty due to temperature reaches its highest value in this partial column, aside from the region above 40 km. An underestimation of the temperature uncertainty used in our theoretical estimation of error budget at these altitudes would lead to an underestimation of the FTIR systematic bias.
The dispersions are, however, small in the middle stratosphere, with values between 4.0 % and 5.3 %, which is within or only slightly larger than the combined random uncertainties.
4.1.5 Upper stratosphere
In the upper stratosphere (29–42 km) we can no longer compare to the sonde data, but we still have the other measurements available for intercomparison. The correlation coefficients for the partial columns are not as good in this partial column, with values between 0.61 and 0.75 for the monthly anomalies, but we should keep in mind that ozone shows much less variability at this altitude range. None of the measurements show a large bias with respect to FTIR, where the median value is between −1 % and −2 % with a dispersion of 4 %–6 %. So considering the systematic and random instrument uncertainties, the four measurements are in agreement. Again, even if small, the bias seems to be in FTIR data only, confirming what is observed with total and other partial column measurements, pointing to a remaining small bias in the infrared spectroscopic parameter in HITRAN2020.
4.2 Drift analysis
In our study, we also want to obtain the difference in total and partial column trends between the measurements (drift). In the analysis of these relative differences between two measurements within one observation pair, we simply apply a linear fit to the time series. Deseasonalizing the time series is not necessary because we are dealing with differences of ozone measurements at the same location, so the ozone variability is canceled out. The slope of the linear trend in the relative differences quantifies the drift. We fit the relative differences between monthly means of data in coincidence Y(t) as
with A0 the intercept, A1 giving the drift, and time t being given in fractional years. The monthly means are first calculated from the two measurements separately, after which we take the relative difference, as in Eq. (6). We have tested the possibility of including a seasonal cycle in the regression analysis, in the case that a seasonal cycle in the differences appears, but it turned out to be barely significant with no impact on the obtained drifts themselves. The 2σ trend error obtained from the fit is corrected with the autocorrelation of the residuals, according to Santer et al. (2008). This results in a higher uncertainty if any correlation remains in the residuals of the fit. This trend uncertainty has the form
with the standard deviation of the fit parameter A1, N the degrees of freedom (not to be confused with DOFS from a retrieval) representing the length of the monthly mean time series, and in which R is the correlation coefficient between the residuals of two consecutive time steps. This error will be used to express our confidence in the drift values obtained in the results. Here “significant” actually refers to a high certainty of the drift value at a 95 % confidence interval. Similarly, “non-significant” refers to only medium to very low confidence in the obtained result. This terminology will be used from now on in the paper.
We summarize the obtained drift and uncertainty for each measurement with respect to FTIR in Table 4. Additionally, Figs. 4 and 5 show the time series of the relative differences within the intercomparison together with the trend analysis. Figure 6 visualizes the obtained drifts in absolute units for the total column as well as all partial columns. These values are obtained by performing the same trend fitting procedure for the absolute differences of the monthly means in Dobson units (DU).
4.2.1 Total column
When we apply the fit from Eq. (11) to the relative differences of FTIR and Umkehr we obtain a very similar drift between FTIR and Dobson (0.4 % per decade) and between FTIR and UV2 (0.4 % per decade), although the periods are different. These two drifts are, however, not significant considering their uncertainties (Udrift=0.4 % per decade and 1.8 % per decade, respectively). If we calculate the drift with Dobson for the same time period as for the UV2, we obtain 0.3 ± 1.1 % per decade. We also give in Table 4 the drift obtained between FTIR and Umkehr total columns (0.6 ± 0.4 % per decade); however, this is a redundant result, as already discussed, with the Umkehr columns being constrained by the Dobson ones. Furthermore, as seen in Fig. 1 and Table 3, the sampling is smaller with Umkehr, which, however, does not impact the uncertainty in the drift.
The small values of the drifts (and their insignificance) prove the very good stability of the three total column ozone measurements at Lauder.
4.2.2 Troposphere
We find non-significant drifts of −0.4 ± 6.1 % per decade between Umkehr and FTIR and −0.1 ± 2.3 % per decade between ozonesonde and FTIR, which are shown in Fig. 4.
We should note that the drift uncertainty is quite large (6.1 % per decade) between the two low-resolution instruments, which is not surprising given the high dispersion value found between the tropospheric measurements in the previous section (18 %, see Table 3). This uncertainty is lower (4.6 % per decade) if we perform the drift analysis on direct partial column comparisons (without performing the smoothing), as detailed in Appendix C.
However, both of these drifts are small and non-significant within the uncertainty, so we can say with strong confidence that there is no drift between the FTIR, Umkehr, and ozonesonde tropospheric ozone datasets in the past 2 decades. These results prove that at Lauder, we have consistent long-term tropospheric ozone measurements from three independent ground-based measurements, suitable for trend studies as planned for TOAR-II.
4.2.3 Lower stratosphere
After performing the intercomparison of the four measurements in this partial column the results show non-significant drifts of −1.0 ± 1.4 % per decade for FTIR with the sonde data and 0.4 ± 2.7 % per decade for FTIR with the lidar data. We do, however, find a positive drift of Umkehr with respect to FTIR of 2.6 ± 1.1 % per decade. In Godin-Beekmann et al. (2022), the Umkehr trend at Lauder was indeed the only one showing a positive trend at this altitude, not only compared to other ground-based measurements at Lauder, but also to a set of satellite overpasses. In Sect. 5 we will elaborate more on how these drifts align with the observed stratospheric trends in Godin-Beekmann et al. (2022).
4.2.4 Middle stratosphere
The resulting drifts between FTIR and the other measurements are 1.5 ± 1.7 % per decade with Umkehr and 0.1 ± 1.4 % per decade with ozonesonde; both are non-significant, and there are two positive drifts of 2.0 ± 0.8 % per decade with lidar and 3.1 ± 2.1 % per decade with MWR. The study of Bernet et al. (2020) also considers both lidar and MWR to be two ground-based measurements in the study of stratospheric ozone trends at Lauder. These trends agree to within 2 % to 3 % with each other, which corresponds to similar numbers in our intercomparison. Unfortunately, for lidar and MWR, we do not have full time series available to have the same period of analysis as for the Umkehr and ozonesonde comparisons. As mentioned above, the lidar measurements are missing 3 years of data from 2012–2015. This incomplete sampling may influence the real lidar trend and potentially the drift with FTIR. Additionally, the MWR data only extend to 2016 at Lauder.
4.2.5 Upper stratosphere
We find negative drifts for Umkehr of −3.2 ± 1.2 % per decade with FTIR and for lidar of −4.0 ± 1.2 % per decade with FTIR, and we find a non-significant drift of MWR of −1.7 ± 2.1 % per decade with FTIR. As mentioned for the drift in the middle stratosphere, the incomplete time series of the lidar data could lie at the origin of the magnitude of this drift. While in this partial column, the conclusions concerning the drift for lidar and MWR with FTIR differ from one another in magnitude, the values are still in agreement with Bernet et al. (2020), where both measurements have small positive trends in the upper stratosphere of around 2 % to 3 % per decade, with MWR peaking at slightly larger trends in the upper stratosphere, which agrees with the smaller drift.
4.2.6 Drift discussion
The significant drifts obtained in the stratospheric columns will unfortunately lead to different long-term stratospheric ozone trends from the different instruments at Lauder. While when comparing only two different techniques, we cannot distinguish which of the two (or if the two) might have stability issues, our study using multiple instruments seems to point to the Umkehr time series for the lower stratosphere and more clearly to the FTIR measurements as one of the drifts responsible in the middle and upper stratosphere.
We therefore tried to explore possible reasons for the drift in FTIR stratospheric time series by tracking instrument and data processing changes. Related to these instrument changes, Appendix D gives a history of calibration for both the FTIR and Dobson instruments. First, it should be noted that the new FTIR retrieval strategy used in this study (Sect. 2.1 and Appendix A1) already significantly improved the drifts that would be obtained if the past IRWG version were used, especially in the troposphere and upper stratosphere. This improvement is explained in more detail in Appendix A2 and is mainly due to a change in regularization. Because drifts are still present with the improved FTIR datasets, we had first a look at the stability of the signal-to-noise ratio of the retrievals, but they are constant over the full time period. Another influence on the drift could be a discontinuous step in the times series caused by instrumental factors, which we discuss in detail in Appendix E. Here we find that a step in May 2018 is present in several time series of differences between FTIR and other measurements and in the FTIR DOFS time series. This step is identified in the FTIR log to a date with major instrument alignment. Such a step as found in FTIR shows the need for a detailed instrument log of all instruments to perform similar change point analyses. While taking into account that fact that the step in the FTIR data does reduce the drift slightly, it is still present and the reason for this drift and those in the other partial columns still requires more in-depth analysis. Because temperature is one of the main drivers of FTIR systematic bias for the middle-upper stratospheric ozone, one should have a closer look in the future at a possible small drift of the NCEP temperature profiles used in the IRWG retrievals.
To better understand these drifts, one should also notice that while Umkehr (although non-significant here), lidar, and MWR all show positive drifts with FTIR in the middle stratosphere, the drift is almost zero with the ozonesonde time series. We address the TCO drop-off for these ozonesonde measurements found at certain sites to see how the signal found at Lauder could affect the results. If we assumed a drift of 3 % per decade in the Lauder ozonesonde time series, then correcting it would propagate to an increase in the drift with respect to FTIR to a value of 1 % per decade in the lower stratosphere and 2 % per decade in the middle stratosphere, bringing these values closer to the drift found with lidar. While it is decided in the present study to use the ozonesonde datasets from HEGIFTOM that follow the WMO/GAW 2021 homogenization procedures (see Sect. 2.5), we have performed the drift study as a test on the ozonesonde dataset, to which the time response correction + calibration (TRCC) method, as described in Smit et al. (2024), has been applied. The bias and dispersion with FTIR worsen with this newly processed ozonesonde dataset. In the middle stratosphere, where the impact of the new correction is largest, we see a bias of −9.3 % and a scatter of 4.3 %. However, it should be mentioned that the drift with FTIR is significantly positive (1.3 ± 1.1 % per decade). This effect is very small in the case of Lauder (1.2 % per decade) but does seem to go in a good direction towards the other ozone stratospheric trend measurements at Lauder, where we see a similar positive drift of the measurements with respect to FTIR. To confirm the changing trend when applying the TRCC method, we perform a drift analysis of the ozonesonde datasets similar to the lidar measurements. In the middle stratosphere we see that the drift (when using ) changes from 2.0 ± 1.3 % per decade for the original ozonesonde dataset to 0.7 ± 1.6 % per decade for the newly processed dataset. This seems to be consistent with the earlier results comparing sonde to FTIR because the significant drift between lidar and sonde that is present with the original sonde data is not there for the newly processed sonde data, putting the trends of the ozonesondes more in line with that of lidar.
However, the new ozonesonde data processing methodology used here is still in the experimental phase, based on simulation chamber data, and should be assessed globally before being implemented widely in the ozonesonde network. The intercomparisons done here underline the high potential of this new method.
One of the main aims of this work is to determine if the discrepancy in the stratospheric ozone trends obtained at Lauder within LOTUS22 (Godin-Beekmann et al., 2022) can be explained by intercomparing the measurements directly and checking their drifts.
One thing to note first is that the FTIR data used in their study use the FTIR V08 (Vigouroux et al., 2008) retrieval strategy, so in order to make a sensible comparison, we should also give the FTIR V08 drift results. Furthermore, the FTIR trends are given for partial columns (both here and in Godin-Beekmann et al., 2022) and not for the profile such as is the case for the other measurements in Godin-Beekmann et al. (2022). Additionally, the FTIR partial column altitude limits were also slightly different in their study than ours. In addition, there is a small difference between the time period used to derive the trends, which is 2000–2020 for Godin-Beekmann et al. (2022). The effect of these small differences on FTIR trends can be seen in Table 5 by looking at FTIR V08 and GB22 FTIR V08. This table shows the trends calculated for our partial columns using a similar LOTUS regression model as in Godin-Beekmann et al. (2022). Figure 7 visualizes this same information in a way comparable to how the results are presented in Fig. 4a of Godin-Beekmann et al. (2022), except that we show them for the same partial columns for all instruments, and we have added the MWR trends, even if it should be kept in mind that they are for the 2000–2016 period, while the other measurements cover 2000–2021.
The comparison allows us to, on the one hand, see the differences between using trends in the profile or using trends in the partial columns; on the other hand, we can find the effect of sampling on the trends. The latter matters because Godin-Beekmann et al. (2022) use all individual measurements to calculate monthly means before deriving trends, while in our drift calculation we make a selection of time coincidences in the intercomparison.
We find similarities in our current trends in Fig. 7 and the ones from Godin-Beekmann et al. (2022): the Umkehr trend is still an outlier in the lower stratosphere and lidar still disagrees with sonde in the middle stratosphere, while Umkehr, in the middle, agrees with both. This means that the use of partial columns and the vertical resolution of the instruments (which have been smoothed with the FTIR averaging kernels here) do not impact the agreement or disagreement that was observed in these altitude ranges in Godin-Beekmann et al. (2022). However, in the upper stratosphere, the use of partial columns makes the comparisons with lidar clearer, and the lidar trend is now in agreement with FTIR, which looked an outlier in Godin-Beekmann et al. (2022). This is partly due to the fact that the lidar trend for this partial column (29–42 km) is 1.8 % per decade, while profile trends showed a mix of positive and negative trends within this large altitude range. The other reason FTIR stopped looking like an outlier is the decreased trend obtained with the new FTIR strategy (from 5 % in Godin-Beekmann et al., 2022, to 3 % in the current study), which is therefore a great improvement for LOTUS. We should also point out that the sonde trends are smaller in the present study than in Godin-Beekmann et al. (2022): −5.1 % and −2.6 % in the lower and middle stratosphere, respectively, while the values were between −7 % and −3 % in the latter study. However, the ozonesonde dataset is the same, pointing to a combined effect of partial column integration and vertical resolution as well as 1 additional year of data in the current study. Similarly as done before in Sect. 4.2.6 for the drifts, we can estimate the impact of a different ozonesonde dataset if we assume a correction for a 3 % drop-off. This would result in an even smaller trend compared to LOTUS22, changing our trends from −5.1 % to −2.1 % per decade for the lower stratosphere and from −2.6 % to 0.4 % per decade in the middle stratosphere.
However, the agreement of our trends with LOTUS22 in the upper-stratospheric trends of FTIR and lidar is not seen in our above drift studies since a significant drift of −4 % was observed between them. We can clearly see the influence of the temporal sampling here. The gap in the lidar data and the poor collocation sampling can affect the drift significantly, and the uncertainty provided for that drift is probably underestimated and would require more sophisticated calculation techniques than applied here.
In the lower stratosphere we see a positive drift of Umkehr with FTIR (2.6 ± 1.1 % per decade). Because the trends of FTIR and Umkehr are different and even of opposite sign, this gives confirmation of the drift we find in the lower stratosphere. For the ozonesonde and lidar, the trends are in good agreement, which is also reflected in the insignificant drifts obtained above. While the drift values (Table 4) correspond well to the observed trends (Table 5) for sonde and lidar, we observe that the drift is smaller than expected in the trend differences (5.2 %) between Umkehr and FTIR. To check if the differences in the Umkehr trend could then be due to the different temporal sampling or the vertical resolution, we give in Table C1 the drift between Umkehr and FTIR without the smoothing, and a similar drift is obtained. Part of the different trend in Umkehr might then be due to the different temporal sampling. Similarly, in the middle stratosphere, the differences observed in the trends between all instruments (except the sondes, which are in agreement with FTIR) and FTIR are reflected only by half of the expected value in the observed drifts.
Long-term measurements of ozone are important to study the recovery of stratospheric ozone as well as the trends of total and tropospheric ozone. Because many sites use different measurements to monitor these ozone trends, there is a need to validate ozone measurements against each other. In this study we take advantage of the multitude of measurements available at the Lauder station (FTIR, Umkehr, ozonesonde, lidar, MWR, Dobson, and UV2) to perform an intercomparison between these measurements. The study, performed in the context of the LOTUS and TOAR-II initiatives, aims to show the biases and drifts, which require more attention to explain the different observed trend between ground-based measurements in Godin-Beekmann et al. (2022). Additionally, within the HEGIFTOM working group of TOAR-II there is a need for an intercomparison evaluating all biases and drifts between tropospheric ozone measurements, which is supplied in this study for the ozonesonde, FTIR, and Umkehr measurements.
The method we use applies a comparison between observations (following Rodgers and Connor, 2003, for the intercomparison of measurements with different vertical resolution) by manipulating the profiles through prior substitution, re-gridding, smoothing, and finally division into partial columns to perform the comparison. These steps are necessary because of the differences in profile retrieval and vertical resolution of the observations. Additionally, we take care to select pairs of comparisons within a specific time window where multiple FTIR measurements (if present) are averaged before performing the comparison.
For each of the instruments and partial columns we find a good correlation with FTIR (from 0.64 to 0.97 for the monthly anomalies). For the total column, we even find a correlation of 0.97. This shows that, even though a bias or drift might be present, the agreement of the long-term ozone measurements between FTIR and the other measurements is strong, capturing the same variability in all partial layers. Only between Umkehr and FTIR in the troposphere do we find a moderate correlation of 0.48, probably due to the lower DOFS of Umkehr in this partial column.
The metrics we use to analyze the intercomparison are the robust median bias and (scaled) MADs to track the accuracy and precision of the observations. These are respectively compared to the combined systematic and random instrument uncertainties. We find good agreement of FTIR with Dobson on the total column concerning the bias (−2.9 %) and MADs (2.0 %) values, similar to Brewer–FTIR comparisons by Schneider et al. (2008). The same overestimation of FTIR is found with respect to UV2, pointing to a slight bias between infrared and UV spectroscopy, but still within the instrument uncertainties.
In the troposphere we find a low bias of −1.9 % with the ozonesondes, but there is a larger value of bias (10.7 %) and MADs (17.9 %) with Umkehr due to the low DOFS we have in this column for Umkehr. Additionally, this can point to an underestimation of the Umkehr random uncertainty budget. When we look at a direct comparison of FTIR to Umkehr without smoothing we actually find a low bias of 1.8 %. So despite the low DOFS of Umkehr, this is a promising result for the use of both FTIR and Umkehr in the troposphere.
In the lower stratosphere we consistently find a negative bias between −1.2 % and −6.8 % for all instruments with respect to FTIR, but all fall within the range of the systematic uncertainties. This is not the case, however, for all values of MADs (between 4.6 % and 8.3 %), which is potentially due to an underestimation of the random instrument uncertainties. Additionally, there is the role of a collocation mismatch between FTIR and lidar measurements, which are taken during the day and the night, respectively.
In the middle stratosphere we again seem to find a negative bias between −5.2 % and −6.6 %, pointing towards values for FTIR that are too high in this partial column not being accounted for in the uncertainty budget. This is possibly related to the temperature profile or the treatment of the instrument line shape (ILS). When we look at the uncertainties in this partial column, we notice a higher error from the temperature profile compared to other partial columns.
In the upper stratosphere none of the measurements show a bias larger than −2 % with respect to FTIR. The four measurements are found to be in agreement in the upper stratosphere when considering the systematic and random uncertainties.
Generally, even though often the bias falls within the systematic uncertainty, we consistently find a small negative bias of all instruments with respect to FTIR. This points to a remaining bias in the infrared spectroscopic parameter in HITRAN2020.
We calculated measurement drift by performing a linear fit to the relative differences. This results in a small but non-significant drift in the total column of 0.4 ± 0.4 % per decade between FTIR and Dobson and similarly 0.4 ± 1.8 % per decade between FTIR and UV2, showing a good stability of all total column measurements at Lauder.
For tropospheric ozone we find no significant drifts between FTIR, Umkehr, and ozonesondes, proving that these are consistent long-term measurements at Lauder suitable for trend studies such as planned in TOAR-II.
We do find measurement drifts in the lower and upper stratosphere for FTIR with Umkehr of 2.6 ± 1.1 % per decade and −3.2 ± 0.9 % per decade, with lidar in the middle and upper stratosphere of 2.1 ± 0.8 % per decade and −3.7 ± 1.2 % per decade, and with MWR in the middle stratosphere of 3.1 ± 1.7 % per decade. The drifts of the measurements in the same direction could point to stability issues for Umkehr in the lower stratosphere and for FTIR in the middle and upper stratosphere. In part, this drift of FTIR is due to a discontinuity in the time series due to an instrument alignment. We also suspect that the temperature profiles from NCEP, which affect the FTIR retrievals, have a potential drift propagating through the retrievals that needs further study.
In comparisons of FTIR and ozonesonde we find no significant drift. This means that there is strong agreement between ozonesonde and FTIR over all partial columns. We did, however, find that when we use newly processed ozonesonde data (Smit et al., 2024), a drift appears in the middle stratosphere between FTIR and sonde that is in line with the results of the other instruments in this partial column. Future trend studies with these ozonesonde data in the stratosphere should be carried out when this new methodology has been globally assessed in the ozonesonde network as well as studies to figure out the nature of the TCO drop-off at certain ozonesonde stations that could impact trend analyses.
When comparing the stratospheric trends of each of the partial columns for every measurement, we see that most of the trends are in agreement with those found in LOTUS22 (Godin-Beekmann et al., 2022), showing that the approach of partial columns in this study does not change the result much from considering the profile itself. Only in the upper stratosphere does the trend change rapidly with altitude, and we find a small difference due to this effect, which in fact reduces the discrepancy between the lidar and FTIR V08 trends at this altitude. These trends are, in turn, mostly in agreement with the drift. The reason for the discrepancy is in part due to the fact that we account for different sampling of the data by constructing the comparison pairs. One example here is the missing 3-year gap in the lidar data at 2012–2015 or the shorter time series of MWR, which stops in 2016. So while remaining drifts are still present, our study explains roughly half of the differences in observed trends in LOTUS22 (Godin-Beekmann et al., 2022) by the different sampling, vertical sensitivity, or time periods and gaps. Additionally, the improved FTIR data in the current work have reduced the differences in the upper-tropospheric trends since LOTUS22.
The good agreement of the three measurements in the troposphere (concerning no significant bias or drift) shows that these are reliable to use for trend studies within HEGIFTOM. Future studies can take advantage of this by merging the FTIR, Umkehr, and ozonesonde measurements in order to provide more accurate trends thanks to the higher sampling (Chang et al., 2024). However, because no strong correlation is found between Umkehr and FTIR in the troposphere and the Umkehr DOFS are consistently low here, one has to be careful when including the Umkehr tropospheric column in the merged product.
The bias and drift teach us that we can have confidence in the ground-based measurements for trend studies at Lauder. However, some attention has to be given to the bias of FTIR in the stratosphere (especially the middle stratosphere), pointing to an underestimation of the infrared spectroscopic line intensities. Attention also has to be given to Umkehr in the troposphere, where we see a lower correlation and high dispersion when compared to FTIR, and to ozonesondes in the middle stratosphere, where the newly developed TRCC correction results in a changed drift from the currently used correction for ozonesonde data. On top of this, great care has to be taken with the effect of temporal sampling, gaps, and jumps in the ozone time series, where we, for example, found an influence on the trend from a discontinuity in the FTIR data related to a major alignment.
Lastly, in Appendix A we have found that employing the new FTIR strategy reduces bias with respect to the other measurements by 2 % to 3 %, which is mostly thanks to the change to HITRAN2020 spectroscopy. Furthermore, the new strategy reduces (at least at Lauder) drifts present in the FTIR V08 data thanks to new regularization, resulting in overall agreement of FTIR with ozonesondes.
A1 New FTIR retrieval strategy
The FTIR ozone retrievals used in this study employ an improved retrieval strategy compared to Vigouroux et al. (2008) (V08) that has been tested at several NDACC sites and recently became the recommended strategy for the IRWG. The most notable changes to the strategy are listed in Table A1. Firstly, necessary input for atmospheric retrievals is a spectroscopic line list including information on the wavenumber of spectral lines and their line strengths for many molecules. Such information is contained in the spectroscopic database of HITRAN (HIgh resolution TRANsmission), and the IRWG at present uses the HITRAN2008 database (Rothman et al., 2009). In the FTIR retrievals used in this study, we have updated the spectroscopic line list to use the latest HITRAN2020 database (Gordon et al., 2022). We find that a result of this change in spectroscopy is generally that retrieved ozone columns are reduced by 2 %–3 %. Secondly, the spectral range that is fitted in the retrieval of ozone (the microwindows) spanned from 1000 to 1005 cm−1 in the V08 strategy. In the new strategy we use a combination of four smaller microwindows, which are chosen such that they avoid strong interference from water vapor lines (García et al., 2022; Schneider and Hase, 2008). Thirdly, the choice of constraints to solve the inverse problem within the retrieval method is chosen as a specific regularization matrix. This matrix can be chosen through the optimal estimation method (OEM; Rodgers, 2000), where the matrix is the inverse of the a priori covariance, or through a so-called smoothing constraint such as the Tikhonov regularization (Tikhonov, 1963). While the first option in theory provides a better regularization from climatological constraints, in practice (such as in the V08 FTIR retrieval strategy) a simplified matrix is usually adopted to represent the variability in the retrieved profile. In the new FTIR strategy we opt to use the Tikhonov regularization, where the strength of the variability has to be determined by considering the DOFS and the retrieval noise error (Steck, 2002). One important difference from the other regularization method is that only the shape of the profile is constrained within the Tikhonov method and not the absolute value, which reduces trend bias due to a statistic a priori. Lastly, since prior information is important and influential for atmospheric retrievals, we also need to consider the choice of the a priori. This a priori information comes from the Whole Atmosphere Community Climate Model (WACCM; Marsh et al., 2013), and we now adopt a different version named IRWG (Keeble et al., 2021) instead of version 6 (Gettelman et al., 2019). However, we find no significant effect in comparison to retrievals performed using the V08 WACCM v6 a priori, but we still adopt this change for consistency with the retrieval of other molecules that are targeted by the IRWG which do have significantly different a priori profiles.
A2 Comparison to the FTIR V08 strategy
To elaborate on the differences between the FTIR V08 retrieval strategy of Vigouroux et al. (2008) and the new strategy explained in Sect. 2.1, here we showcase the intercomparison study from above performed with both retrieval strategies. First of all, we consider the bias of the total column of FTIR with Umkehr. The bias of TCO retrieved with the FTIR V08 strategy is −5.7 % with Umkehr, in relative difference as before. This value is higher in absolute value than that found using the new retrieval strategy, where we find a bias of −2.9 % with Umkehr. A similar reduction of 1 %–3 % in the bias is also found in most partial columns compared to the other measurements. Additionally, the MADs value for the differences in total column between FTIR and Umkehr are also seen to be reduced from 2.0 % using the V08 strategy to 1.7 % using the new strategy. This shift in lower ozone columns for the new FTIR strategy is mostly due to the change in spectroscopy from HITRAN2008 to HITRAN2020. Namely, when performing retrievals using the V08 strategy and only changing the spectroscopic data, the columns are generally seen to be reduced by 2 %–3 %, which matches the changes in the biases with respect to the other measurements and brings them all into decent agreement with one another considering the instrument uncertainties.
Second of all, the new FTIR retrieval strategy also causes differences in the drifts with respect to the other ground-based instruments. For comparison with earlier results, the drifts derived through the same intercomparison method, but now using the FTIR V08 strategy, are shown in Table A2. Overall, the change from the V08 to the new strategy improves most of the drifts and some even change from being significant to being non-significant within the trend error. In the troposphere we find that, while the ozonesonde data do have a drift with respect to FTIR V08 observations, this drift is no longer present using the new FTIR strategy. In the lower stratosphere, while the drifts do change slightly in value, the conclusions remain the same. In the middle stratosphere the drift with Umkehr is reduced to become non-significant with the new FTIR data. However, one change to remark on here is that, while all drifts in the middle stratosphere are reduced, the drift of MWR with the new FTIR actually increases. This is mainly due to the fact that the time span of the MWR data only lasts until October 2016. The FTIR trend computed with this shorter time series is actually seen to increase when changing from the V08 strategy to the new strategy, which is the reverse of what happens when the full time series is considered. Potentially then, if the missing 5 years had been included in the MWR observations, following the logic of the other measurements, the drift would have decreased when using the new FTIR and may even no longer be significant. Lastly, in the upper stratosphere, the conclusions remain unchanged when adopting either the V08 or new FTIR retrieval strategy. Drifts of both Umkehr and lidar with the new FTIR are lower in absolute value than with the V08 FTIR data.
Previously, we saw that the change in spectroscopy affects the retrieved ozone columns for FTIR, reducing the bias with all other measurements. This effect, however, is the same over the full dataset and thus will not alter the derived drifts. The relevant change in the retrieval strategy here is that the regularization in the new strategy uses Tikhonov regularization instead of optimal estimation or that we use a higher regularization strength than in the V08 strategy, bringing down the DOFS. The change in regularization slightly reduces both the positive and the negative trends of FTIR in all partial columns. The consequence we see here is that, when using Tikhonov regularization, the drifts generally improve, and we even find that there is no significant drift between FTIR and ozonesonde for any of the partial columns.
The time window where two measurements are compared to one another should not be too large to avoid comparing different times of day when ozone could naturally change within the diurnal cycle or by comparing completely different air masses. In part, this is determined by analyzing which time window has the lowest bias and scatter between the measurements, which are all listed in Table B1.The choice is also made such that there are plenty of comparisons available to sample the full time coverage, because sampling is crucial in long-term intercomparison studies, and by simultaneously checking the behavior of the drift. The Umkehr observations are only made at sunrise and sunset, so we find that 6 h is the ideal time window to still have plenty of comparison pairs over the full time series with the best values of M and MADs over the partial columns as seen in Table B1. For the same reason, the time window of 6 h is selected for the comparison to the ozonesonde observations. Because these measurements are not very frequent, we find that we need a large enough window to get a dense enough sampling over the time series. The microwave radiometer measurements are taken a lot more frequently, so a smaller time window of 3 h here is sufficiently large enough to construct many comparison pairs. The time window of 1 h does not really improve the bias or scatter and furthermore makes the bias more negative. It is important not to take a time window that is too large because of the diurnal variation and short-term variability, as discussed in Sauvageat et al. (2023). They note high variation, especially at the stratopause. We therefore check the extent of the variability in the upper stratosphere for the MWR measurements. We find the short-term variability to be at most 18 % and assess from this that a 3 h time window is sufficiently small (with a mean value of 1.1 %) such that the diurnal variation will not impact the intercomparison study. Most problematic to construct the comparison pairs, however, are the lidar observations. These are taken exclusively at night, while FTIR measurements are taken exclusively during the day because direct sunlight is necessary. A time window of 12 h is necessary to achieve a decent sampling over the available time series.
We explore the difference between the comparisons performed with and without smoothing the high-resolution profile. Both results are shown in Fig. C1, where the bias is shown over the full ozone profile together with the MADs in the shaded areas. When we perform the intercomparison without smoothing, a lot more oscillation is seen in the relative difference of the profiles. This is especially pronounced for the sonde data, which (as we can also see in Fig. 3) show oscillation that is a lot sharper than in the FTIR profile. These are actual profile measurements from ozonesondes, so direct comparison with FTIR does make sense and limits any influence of trends in the FTIR averaging kernel on the ozonesonde trends (García et al., 2012). However, because the vertical resolution of FTIR is much smaller, these high spatial oscillations can never be observed, so it makes sense to adjust the ozonesonde profile to incorporate the same vertical information. We see that this results in an overall better comparison of the profile to FTIR. Similar results, although less pronounced, can be seen for the comparison with the other measurements. When we divide into partial columns, this effect of smoothing on the derived results should not be too big because we chose the columns such that we have around 1 DOFS for FTIR. The only exception is in comparing FTIR to Umkehr in the partial columns where the Umkehr DOFS are less than 1, where we now use the Umkehr averaging kernels instead. We see, for example, that the only place where the profile comparison seems to get worse when applying smoothing is for the Umkehr comparison in the troposphere (where Umkehr reaches 0.5 DOFS).
To analyze the effects of smoothing on the drift between the instruments, Table C1 shows these values with their uncertainties when smoothing is not applied during the intercomparison. No big differences are seen and the drifts that are deemed significant considering the uncertainty are the same both with and without smoothing. For the ozonesonde comparison, the drift is reduced slightly in all partial columns, strengthening the use of a smoothed profile in this comparison. For the other measurements, however, the changes are not as consistent. Both lidar and Umkehr have partial columns where the drift improves and worsens after smoothing the profile. For the MWR comparison we see a small increase in the drift in both partial columns. Because the changes are not very large, therefore not changing conclusions about significance within the drift uncertainty, and generally the bias and drifts seem to improve (especially with ozonesonde data) we have chosen to work with a smoothed profile in the intercomparison study.
D1 FTIR
FTIR instrument performance (accuracy, precision, and stability) is routinely assessed via monthly cell measurements. The closed cell contains a low-pressure gas. The cells employed to date have contained pure mixtures of ∼ 0.2 hPa HBr or N2O (Coffey et al., 1998; Hase, 2012). Analysis of the cell spectra is via the code LINEFIT (Hase et al., 1999), which is used to retrieve the instrument line shape (ILS) and cell total column abundance along with other instrument diagnostics. Multiple measurements over time give instrument stability and precision. Bias (accuracy) is deduced from the difference in the retrieved total column from the reference total column amount.
At Lauder, monthly HBr cell tests were made on the Bruker 120HR from 2002 to 2018. For the Bruker 125HR cell tests (2018 to present) a N2O cell was used. Figure D1 displays the modulation efficiency (ME: measured ILS relative to theoretical ILS) for the Lauder 120HR. Values with ∼ 4 % of unity indicate a well-aligned instrument (personal communication with Frank Hase). Between 2002 and 2018 there were over 500 instrument events. Long-term observations were constantly interspersed with tests as well as component failures and changes. Each event has the potential to influence instrument performance. Two prominent examples are large step changes in the ILS ME in December 2010 and August 2013 (see Fig. D1). The cause of these was major optical realignment. Such ME step changes are not uncommon within the NDACC FTIR community (e.g., García et al., 2021) and the effect (of ME changes) on total (and partial column) retrievals has been investigated recently by García et al. (2021) and Sun et al. (2018). The effect of the December 2010 and August 2013 ME changes are not discernible in instrument comparisons.
The statistically inferred discontinuity identified in May 2018 (Fig. E1) is related to the change of the instrumentation from the Bruker 120HR to Bruker 125HR. The effect of this instrument transition on total column abundances for multiple species has been documented in a comparison between the 120HR and the 125HR (Dan Smale, personal communication, 2023) and can be obtained by contacting Dan Smale via dan.smale@niwa.co.nz.
D2 Dobson
The Lauder Dobson (no. 72) undergoes routine monthly calibrations using a mercury lamp and quartz halogen lamps to monitor variations in wavelength and instrument stability. As part of NDACC protocols, every 5 years the Lauder Dobson is transported to Melbourne to be intercompared with the Regional Standard Dobson (no. 105), maintained and operated by the Australian Bureau of Meteorology. Dobson intercomparisons since 2000 were performed in 2006, 2012, 2017, and 2022.
An issue due to rain damage was identified during the 2012 calibration campaign and data from 2006–2012 were reprocessed. A full description of this is given in Evans et al. (2017).
NOAA installed the automated Dobson (no. 72) at Lauder in 1987. The automation system was updated to the WinDobson system in 2012. Within the NOAA Dobson network, semi-automation refers to capturing R-dial values with an encoder and assisting the measurement procedure with a computer. The Lauder Dobson automation also includes table rotation and zenith hatch control for unattended zenith observations; direct-Sun observations require an operator to open the dome and position the Sun director.
For the 2012 intercomparison (IC2012), a comparison was made with the Secondary Reference Instrument (no. 65). The final error with the World Standard Dobson (no. 83) was adjusted to zero. Similar adjustments were made in the 2006 calibration as well. During the last two intercomparisons (IC2017 and IC2022), the World Standard Dobson (no. 83), maintained and operated by NOAA at Boulder and Mauna Loa, also participated in the Melbourne campaign, so the Lauder Dobson is directly traceable to the World Standard Dobson (no. 83). From the IC2022 report, the Lauder NAD ADD value (0.66) implied an average −0.8 % error in the calculated ozone value over the range Mu = 1.1 to 2.5 for total ozone of 300 DU. Generally, an error of ±1 % or less is within the acceptable range, and therefore no recalculations have been applied to Lauder Dobson data since IC2017.
In the drift analysis we found that temporal sampling has an important influence on the calculated drift between two measurements. Here we additionally study the influence of potential steps or discontinuities (change point), which, for example, could arise from physical changes to the measurement instrument. In order to find a change point in the time series of relative differences, we use the Lanzante change point detection algorithm (Lanzante, 1996), as is similarly done in García et al. (2014). The Lanzante algorithm iteratively finds a change point from summing the ranks of the time series from the beginning to each point in the series. Afterwards the series is adjusted using the median of the subseries enclosed by the currently found change points. This method is repeated for the adjusted time series until the found change point is statistically insignificant (p value < 0.05). This method of change point detection is purely statistical, hopefully aligning with changes to the retrieval strategy or changes to the instrument itself as a cause of the found step.
This method is applied to the relative differences in total and partial columns where we have calculated the drifts in order to find any recurring discontinuities that could point to steps in any of the measurement time series. Multiple change points over the different intercomparisons are identified using the Lanzante method. One of these steps in the middle of 2018 seems to reappear for multiple measurement comparisons, pointing to a step in the FTIR data (being the reference measurement). To analyze this discontinuity, we show the time series of FTIR DOFS in Fig. E1 and again apply the Lanzante change point detection. Because seasonality is present (which was not the case for the relative differences), we first apply a seasonal fitting to the time series and subtract it. We fit the DOFS Y(t) using
with A0 the intercept, A1 the slope, and the other terms representing the seasonality. From the deseasoned DOFS we find again the same change point we found for multiple relative differences in May 2018. Since the retrieval strategy is the same over the full time series, we search for the cause of the steps in the instrument itself. From the FTIR instrument logs, we find that on 10 May 2018 there was a “major alignment”, which is the most likely cause of the step in the FTIR data.
Once this change point is found, we can recalculate the drift for each time series of relative differences both before and after this point to find the influence of the discontinuity on the overall drift. Because the step is towards the end of the time series and there are not a lot of data points, the drift to the right of this step has a very high uncertainty. The drift on the left of the step is always similar to the overall drift from Table 4. This means that, for this time series, the step in the FTIR dataset caused by the major alignment does not significantly affect the overall drift reported in this study.
For the other two change points, we cannot identify a clear instrumental reason. Similar to the previous change point, if we calculate the drift left and right of the discontinuities, we find drifts of the same order as for the total time series, but with larger uncertainties. Such a change point analysis requires more attention and future work to identify the discontinuities for each instrument and relate them to changes to the instrument or data processing techniques, but this falls beyond the scope of this paper.
The ground-based datasets used in this article are collectively available in the following repository: https://doi.org/10.18758/AS5RZ1OH (Björklund et al., 2024). Information about each dataset can be found at their individual source location: current public data for the FTIR (Smale and Robinson, 2024), lidar (https://doi.org/10.21336/gen.0x48-sm13, Querel and Swart, 2020), and MWR (Nedoluha et al., 2024) can be found via NDACC at https://www-air.larc.nasa.gov/missions/ndacc/data.html (last access: 18 November 2024). The FTIR data will be updated here with the new strategy explained in the paper. NOAA Dobson total column ozone measurements can also be found on the NOAA GML FTP website here: https://gml.noaa.gov/aftp/ozwv/Dobson/ (McConville and McClure, 2024). Likewise, the monthly mean optimized and homogenized Umkehr profiles can be found on the NOAA GML FTP server here: https://gml.noaa.gov/aftp/ozwv/Dobson/AC4/Umkehr/Optimized/ (Petropavlovskikh and Miyagawa, 2024). Ozonesondes: the homogenized Lauder ozonesonde time series are available via the HEGIFTOM FTP server at https://hegiftom.meteo.be/datasets/ozonesondes (Van Malderen, 2024).
RB carried out the majority of the intercomparison study and wrote the major part of the text. This was done in close collaboration with CV, who supplied the trend results and additionally wrote significant parts of the text. The code to perform the intercomparisons was provided by BL. PE, IP, GN, RVM, AG, and RQ provided text concerning their instrument expertise. Additionally, DS and RQ provided the full text and figures for Appendix D. RB, CV, OEG, JH, GN, IO, IP, RQ, DS, RVM, and MDM all participated in the discussion and provided comments on the text. DS, PE, AG, KM, MK, GN, IP, DP, RQ, JR, HS, PS, and RVM all contributed to supplying the datasets, and RVM additionally created a preliminary ozonesonde dataset with the TRCC method.
At least one of the (co-)authors is a member of the editorial board of Atmospheric Measurement Techniques. The peer-review process was guided by an independent editor, and the authors also have no other competing interests to declare.
Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.
This article is part of the special issue “Tropospheric Ozone Assessment Report Phase II (TOAR-II) Community Special Issue (ACP/AMT/BG/GMD inter-journal SI)”. It is not associated with a conference.
The work of Robin Björklund has been supported by BIRA-IASB and is performed within the context of LOTUS and TOAR-II.
This research has been supported by BIRA-IASB.
This paper was edited by Gabriele Stiller and reviewed by Sophie Godin-Beekmann and one anonymous referee.
Ball, W. T., Alsing, J., Mortlock, D. J., Staehelin, J., Haigh, J. D., Peter, T., Tummon, F., Stübi, R., Stenke, A., Anderson, J., Bourassa, A., Davis, S. M., Degenstein, D., Frith, S., Froidevaux, L., Roth, C., Sofieva, V., Wang, R., Wild, J., Yu, P., Ziemke, J. R., and Rozanov, E. V.: Evidence for a continuous decline in lower stratospheric ozone offsetting ozone layer recovery, Atmos. Chem. Phys., 18, 1379–1394, https://doi.org/10.5194/acp-18-1379-2018, 2018. a
Basher, R. E.: Review of the Dobson spectrophotometer and its accuracy, in: Atmospheric ozone; Proceedings of the Quadrennial, edited by: Zerefos, C. S. and Ghazi, A., Springer, p. 387, https://doi.org/10.1007/978-94-009-5313-0_78, 1985. a
Bass, A. M. and Paur, R. J.: The ultraviolet cross-sections of ozone. I. The measurements. II - Results and temperature dependence, in: Atmospheric ozone; Proceedings of the Quadrennial, edited by: Zerefos, C. S. and Ghazi, A., Springer, 606–616, https://doi.org/10.1007/978-94-009-5313-0_120, 1985. a
Bernet, L., Boyd, I., Nedoluha, G., Querel, R., Swart, D., and Hocke, K.: Validation and Trend Analysis of Stratospheric Ozone Data from Ground-Based Observations at Lauder, New Zealand, Remote Sens., 13, 109, https://doi.org/10.3390/rs13010109, 2020. a, b, c, d, e
Björklund, R., Vigouroux, C., Effertz, P., Shiona, H., Smale, D., Smale, P., Van Malderen, R., De Maziere, M., García, O., Geddes, A., Hannigan, J., Miyagawa, K., Kotkamp, M., Langerock, B., Nedoluha, G., Ortega, I., Petropavlovskikh, I., Poyraz, D., Querel, R., and Robinson, J.: Partial and total ozone column measurements at Lauder (45S, 170E) from FTIR, Dobson, UV2, lidar, ozonesonde, microwave radiometer (Version 1), Royal Belgian Institute for Space Aeronomy [data set], https://doi.org/10.18758/AS5RZ1OH, 2024. a
Brasseur, G. and Solomon, S.: Aeronomy of the Middle Atmosphere: Chemistry and Physics of the Stratosphere and Mesosphere, 3rd rev. and enlarged edn., Springer, Vol. 32, https://doi.org/10.1007/1-4020-3824-0, 2005. a
Chang, K.-L., Cooper, O. R., Gaudel, A., Petropavlovskikh, I., Effertz, P., Morris, G., and McDonald, B. C.: Technical note: Challenges in detecting free tropospheric ozone trends in a sparsely sampled environment, Atmos. Chem. Phys., 24, 6197–6218, https://doi.org/10.5194/acp-24-6197-2024, 2024. a
Coffey, M. T., Goldman, A., Hannigan, J. W., Mankin, W. G., Schoenfeld, W. G., Rinsland, C. P., Bernardo, C., and Griffith, D. W. T.: Improved vibration-rotation (0-1) HBr line parameters for validating high resolution infrared atmospheric spectra measurements., J. Quant. Spectrosc. Ra., 60, 863–867, https://doi.org/10.1016/S0022-4073(98)00088-0, 1998. a
Connor, B. J., Parrish, A., Tsou, J.-J., and McCormick, M. P.: Error analysis for the ground-based microwave ozone measurements during STOIC, J. Geophys. Res., 100, 9283–9291, https://doi.org/10.1029/94JD00413, 1995. a
De Mazière, M., Thompson, A. M., Kurylo, M. J., Wild, J. D., Bernhard, G., Blumenstock, T., Braathen, G. O., Hannigan, J. W., Lambert, J.-C., Leblanc, T., McGee, T. J., Nedoluha, G., Petropavlovskikh, I., Seckmeyer, G., Simon, P. C., Steinbrecht, W., and Strahan, S. E.: The Network for the Detection of Atmospheric Composition Change (NDACC): history, status and perspectives, Atmos. Chem. Phys., 18, 4935–4964, https://doi.org/10.5194/acp-18-4935-2018, 2018. a
Evans, R. D., Petropavlovskikh, I., McClure-Begley, A., McConville, G., Quincy, D., and Miyagawa, K.: Technical note: The US Dobson station network data record prior to 2015, re-evaluation of NDACC and WOUDC archived records with WinDobson processing software, Atmos. Chem. Phys., 17, 12051–12070, https://doi.org/10.5194/acp-17-12051-2017, 2017. a
García, O. E., Schneider, M., Redondas, A., González, Y., Hase, F., Blumenstock, T., and Sepúlveda, E.: Investigating the long-term evolution of subtropical ozone profiles applying ground-based FTIR spectrometry, Atmos. Meas. Tech., 5, 2917–2931, https://doi.org/10.5194/amt-5-2917-2012, 2012. a, b, c, d
García, O. E., Schneider, M., Hase, F., Blumenstock, T., Sepúlveda, E., and González, Y.: Quality assessment of ozone total column amounts as monitored by ground-based solar absorption spectrometry in the near infrared (> 3000 cm−1), Atmos. Meas. Tech., 7, 3071–3084, https://doi.org/10.5194/amt-7-3071-2014, 2014. a
García, O. E., Schneider, M., Sepúlveda, E., Hase, F., Blumenstock, T., Cuevas, E., Ramos, R., Gross, J., Barthlott, S., Röhling, A. N., Sanromá, E., González, Y., Gómez-Peláez, Á. J., Navarro-Comas, M., Puentedura, O., Yela, M., Redondas, A., Carreño, V., León-Luis, S. F., Reyes, E., García, R. D., Rivas, P. P., Romero-Campos, P. M., Torres, C., Prats, N., Hernández, M., and López, C.: Twenty years of ground-based NDACC FTIR spectrometry at Izaña Observatory – overview and long-term comparison to other techniques, Atmos. Chem. Phys., 21, 15519–15554, https://doi.org/10.5194/acp-21-15519-2021, 2021. a, b
García, O. E., Sanromá, E., Schneider, M., Hase, F., León-Luis, S. F., Blumenstock, T., Sepúlveda, E., Redondas, A., Carreño, V., Torres, C., and Prats, N.: Improved ozone monitoring by ground-based FTIR spectrometry, Atmos. Meas. Tech., 15, 2557–2577, https://doi.org/10.5194/amt-15-2557-2022, 2022. a
Geddes, A., Liley, B., McKenzie, R., Kotkamp, M., and Querel, R.: Novel use of an adapted ultraviolet double monochromator for measurements of global and direct irradiance, ozone, and aerosol, Atmos. Meas. Tech., 17, 827–838, https://doi.org/10.5194/amt-17-827-2024, 2024. a, b, c
Gettelman, A., Mills, M. J., Kinnison, D. E., Garcia, R. R., Smith, A. K., Marsh, D. R., Tilmes, S., Vitt, F., Bardeen, C. G., McInerny, J., Liu, H. L., Solomon, S. C., Polvani, L. M., Emmons, L. K., Lamarque, J. F., Richter, J. H., Glanville, A. S., Bacmeister, J. T., Phillips, A. S., Neale, R. B., Simpson, I. R., DuVivier, A. K., Hodzic, A., and Randel, W. J.: The Whole Atmosphere Community Climate Model Version 6 (WACCM6), J. Geophys. Res.-Atmos., 124, 12380–12403, https://doi.org/10.1029/2019JD030943, 2019. a
Godin-Beekmann, S., Azouz, N., Sofieva, V. F., Hubert, D., Petropavlovskikh, I., Effertz, P., Ancellet, G., Degenstein, D. A., Zawada, D., Froidevaux, L., Frith, S., Wild, J., Davis, S., Steinbrecht, W., Leblanc, T., Querel, R., Tourpali, K., Damadeo, R., Maillard Barras, E., Stübi, R., Vigouroux, C., Arosio, C., Nedoluha, G., Boyd, I., Van Malderen, R., Mahieu, E., Smale, D., and Sussmann, R.: Updated trends of the stratospheric ozone vertical distribution in the 60° S–60° N latitude range based on the LOTUS regression model, Atmos. Chem. Phys., 22, 11657–11673, https://doi.org/10.5194/acp-22-11657-2022, 2022. a, b, c, d, e, f, g, h, i, j, k, l, m, n, o, p, q, r, s, t, u, v, w, x, y, z
Gordon, I., Rothman, L., Hargreaves, R., Hashemi, R., Karlovets, E., Skinner, F., Conway, E., Hill, C., Kochanov, R., Tan, Y., Wcisło, P., Finenko, A., Nelson, K., Bernath, P., Birk, M., Boudon, V., Campargue, A., Chance, K., Coustenis, A., Drouin, B., Flaud, J., Gamache, R., Hodges, J., Jacquemart, D., Mlawer, E., Nikitin, A., Perevalov, V., Rotger, M., Tennyson, J., Toon, G., Tran, H., Tyuterev, V., Adkins, E., Baker, A., Barbe, A., Canè, E., Császár, A., Dudaryonok, A., Egorov, O., Fleisher, A., Fleurbaey, H., Foltynowicz, A., Furtenbacher, T., Harrison, J., Hartmann, J., Horneman, V., Huang, X., Karman, T., Karns, J., Kassi, S., Kleiner, I., Kofman, V., Kwabia-Tchana, F., Lavrentieva, N., Lee, T., Long, D., Lukashevskaya, A., Lyulin, O., Makhnev, V., Matt, W., Massie, S., Melosso, M., Mikhailenko, S., Mondelain, D., Müller, H., Naumenko, O., Perrin, A., Polyansky, O., Raddaoui, E., Raston, P., Reed, Z., Rey, M., Richard, C., Tóbiás, R., Sadiek, I., Schwenke, D., Starikova, E., Sung, K., Tamassia, F., Tashkun, S., Vander Auwera, J., Vasilenko, I., Vigasin, A., Villanueva, G., Vispoel, B., Wagner, G., Yachmenev, A., and Yurchenko, S.: The HITRAN2020 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 277, 107949, https://doi.org/10.1016/j.jqsrt.2021.107949, 2022. a, b, c, d, e
Gotz, F. W. P., Meetham, A. R., and Dobson, G. M. B.: The Vertical Distribution of Ozone in the Atmosphere, P. Roy. Soc. Lond. A, 145, 416–446, https://doi.org/10.1098/rspa.1934.0109, 1934. a
Gulev, S. K., Thorne, P. W., Ahn, J., Dentener, F. J., Domingues, C. M., Gerland, S., Gong, D. S., Kaufman, S., Nnamchi, H. C., Quaas, J., Rivera, J. A., Sathyendranath, S., Smith, S. L., Trewin, B., von Shuckmann, K., and Vose, R. S.: Changing State of the Climate System, in: Climate Change 2021: The Physical Science Basis. Contribution of Working Group I to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change, edited by: Masson-Delmotte, V., Zhai, P., Pirani, A., Connors, S. L., Péan, C., Berger, S., Caud, N., Chen, Y., Goldfarb, L., Gomis, M. I., Huang, M., Leitzell, K., Lonnoy, E., Matthews, J. B. R., Maycock, T. K., Waterfield, T., Yelekçi, O., Yu, R., and Zhou, B., Cambridge University Press, Cambridge, United Kingdom and New York, NY, USA, 287–422, https://doi.org/10.1017/9781009157896.004, 2021. a
Hansen, J., Sato, M., and Ruedy, R.: Radiative forcing and climate response, J. Geophys. Res., 102, 6831–6864, https://doi.org/10.1029/96JD03436, 1997. a
Hase, F.: Improved instrumental line shape monitoring for the ground-based, high-resolution FTIR spectrometers of the Network for the Detection of Atmospheric Composition Change, Atmos. Meas. Tech., 5, 603–610, https://doi.org/10.5194/amt-5-603-2012, 2012. a
Hase, F., Blumenstock, T., and Paton-Walsh, C.: Analysis of the Instrumental Line Shape of High-Resolution Fourier Transform IR Spectrometers with Gas Cell Measurements and New Retrieval Software, Appl. Optics, 38, 3417–3422, https://doi.org/10.1364/AO.38.003417, 1999. a
Jacob, D. J.: Heterogeneous chemistry and tropospheric ozone, Atmos. Environ., 34, 2131–2159, https://doi.org/10.1016/S1352-2310(99)00462-8, 2000. a
Jones, A., Urban, J., Murtagh, D. P., Sanchez, C., Walker, K. A., Livesey, N. J., Froidevaux, L., and Santee, M. L.: Analysis of HCl and ClO time series in the upper stratosphere using satellite data sets, Atmos. Chem. Phys., 11, 5321–5333, https://doi.org/10.5194/acp-11-5321-2011, 2011. a
Keckhut, P., McDermid, S., Swart, D., McGee, T., Godin-Beekmann, S., Adriani, A., Barnes, J., Baray, J.-L., Bencherif, H., Claude, H., di Sarra, A. G., Fiocco, G., Hansen, G., Hauchecorne, A., Leblanc, T., Lee, C. H., Pal, S., Megie, G., Nakane, H., Neuber, R., Steinbrecht, W., and Thayer, J.: Review of ozone and temperature lidar validations performed within the framework of the Network for the Detection of Stratospheric Change, J. Environ. Monit., 6, 721–733, https://doi.org/10.1039/B404256E, 2004. a
Keeble, J., Hassler, B., Banerjee, A., Checa-Garcia, R., Chiodo, G., Davis, S., Eyring, V., Griffiths, P. T., Morgenstern, O., Nowack, P., Zeng, G., Zhang, J., Bodeker, G., Burrows, S., Cameron-Smith, P., Cugnet, D., Danek, C., Deushi, M., Horowitz, L. W., Kubin, A., Li, L., Lohmann, G., Michou, M., Mills, M. J., Nabat, P., Olivié, D., Park, S., Seland, Ø., Stoll, J., Wieners, K.-H., and Wu, T.: Evaluating stratospheric ozone and water vapour changes in CMIP6 models from 1850 to 2100, Atmos. Chem. Phys., 21, 5015–5061, https://doi.org/10.5194/acp-21-5015-2021, 2021. a
Kim, S.-Y., Kim, E., and Kim, W. J.: Health Effects of Ozone on Respiratory Diseases, Tubercylosis and Respiratory Diseases (Seoul), 83, S6–S11, https://doi.org/10.4046/trd.2020.0154, 2020. a
Komhyr, W. D. and Evans, R. D.: Operations Handbook: Ozone Observations with a Dobson Spectrophotometer, vol. 183, World Meteorological Organization Global Atmosphere Watch GAW, https://gml.noaa.gov/ozwv/dobson/GAW183-Dobson-WEB.pdf (last access: 18 November 2024), 2008. a
Kramarova, N. A., Bhartia, P. K., Frith, S. M., McPeters, R. D., and Stolarski, R. S.: Interpreting SBUV smoothing errors: an example using the quasi-biennial oscillation, Atmos. Meas. Tech., 6, 2089–2099, https://doi.org/10.5194/amt-6-2089-2013, 2013. a
Kurylo, M. and Solomon, S.: United States NASA Administration Upper Atmosphere Research Program and NOAA Climate and Global Change Program, Network for the detection of stratospheric change: a status and implementation report, NASA, Washington, DC, 1990. a
Langerock, B., De Mazière, M., Hendrick, F., Vigouroux, C., Desmet, F., Dils, B., and Niemeijer, S.: Description of algorithms for co-locating and comparing gridded model data with remote-sensing observations, Geosci. Model Dev., 8, 911–921, https://doi.org/10.5194/gmd-8-911-2015, 2015. a
Lanzante, J. R.: Resistant, Robust and Non-Parametric Techniques for the Analysis of Climate Data: Theory and Examples, Including Applications to Historical Radiosonde Station Data, Int. J. Climatol., 16, 1197–1226, https://doi.org/10.1002/(SICI)1097-0088(199611)16:11<1197::AID-JOC89>3.0.CO;2-L, 1996. a
Leblanc, T., Sica, R. J., van Gijsel, J. A. E., Godin-Beekmann, S., Haefele, A., Trickl, T., Payen, G., and Gabarrot, F.: Proposed standardized definitions for vertical resolution and uncertainty in the NDACC lidar ozone and temperature algorithms – Part 1: Vertical resolution, Atmos. Meas. Tech., 9, 4029–4049, https://doi.org/10.5194/amt-9-4029-2016, 2016. a
Manney, G. L., Santee, M. L., Rex, M., Livesey, N. J., Pitts, M. C., Veefkind, P., Nash, E. R., Wohltmann, I., Lehmann, R., Froidevaux, L., Poole, L. R., Schoeberl, M. R., Haffner, D. P., Davies, J., Dorokhov, V., Gernandt, H., Johnson, B., Kivi, R., Kyrö, E., Larsen, N., Levelt, P. F., Makshtas, A., McElroy, C. T., Nakajima, H., Parrondo, M. C., Tarasick, D. W., von der Gathen, P., Walker, K. A., and Zinoviev, N. S.: Unprecedented Arctic ozone loss in 2011, Nature, 478, 469–475, https://doi.org/10.1038/nature10556, 2011. a
Marsh, D. R., Mills, M. J., Kinnison, D. E., Lamarque, J.-F., Calvo, N., and Polvani, L. M.: Climate Change from 1850 to 2005 Simulated in CESM1(WACCM), J. Climate, 26, 7372–7391, https://doi.org/10.1175/JCLI-D-12-00558.1, 2013. a, b
McConville, G. and McClure, A.: Dobson Ozone Spectrophotometer Measurements, NOAA [data set], https://gml.noaa.gov/aftp/ozwv/Dobson/, last access: 18 November 2024. a
McDermid, I. S., Bergwerff, J. B., Bodeker, G., Boyd, I. S., Brinksma, E. J., Connor, B. J., Farmer, R., Gross, M. R., Kimvilakani, P., Matthews, W. A., McGee, T. J., Ormel, F. T., Parrish, A., Singh, U., Swart, D. P. J., Tsou, J. J., Wang, P. H., and Zawodny, J.: OPAL: Network for the Detection of Stratospheric Change Ozone Profiler Assessment at Lauder, New Zealand 1. Blind intercomparison, J. Geophys. Res., 103, 28683–28692, https://doi.org/10.1029/98JD02706, 1998. a
McPeters, R. D. and Labow, G. J.: Climatology 2011: An MLS and sonde derived ozone climatology for satellite retrieval algorithms, J. Geophys. Res.-Atmos., 117, D10303, https://doi.org/10.1029/2011JD017006, 2012. a
Nedoluha, G., Gomez, M., and Boyd, I. S.: Ground-based 110 GHz microwave spectrometer Mixing ratio profile of O3, Naval Research Lab [data set], https://www-air.larc.nasa.gov/missions/ndacc/data.html, last access: 18 November 2024. a
Parrish, A.: Millimeter-wave remote sensing of ozone and trace constituents in the stratosphere, P. IEEE, 82, 1915–1929, https://doi.org/10.1109/5.338079, 1994. a
Parrish, A., Connor, B. J., Tsou, J. J., McDermid, I. S., and Chu, W. P.: Ground-based microwave monitoring of stratospheric ozone, J. Geophys. Res., 97, 2541–2546, https://doi.org/10.1029/91JD02914, 1992. a
Petropavlovskikh, I. and Miyagawa, K.: NOAA Dobson Umkehr Optimized Ozone Profile Data, Monthly Averages, NOAA GML [data set], https://gml.noaa.gov/aftp/ozwv/Dobson/AC4/Umkehr/Optimized/, last access: 18 November 2024. a
Petropavlovskikh, I., Bhartia, P. K., and DeLuisi, J.: New Umkehr ozone profile retrieval algorithm optimized for climatological studies, Geophys. Res. Lett., 32, L16808, https://doi.org/10.1029/2005GL023323, 2005. a
Petropavlovskikh, I., Miyagawa, K., McClure-Beegle, A., Johnson, B., Wild, J., Strahan, S., Wargan, K., Querel, R., Flynn, L., Beach, E., Ancellet, G., and Godin-Beekmann, S.: Optimized Umkehr profile algorithm for ozone trend analyses, Atmos. Meas. Tech., 15, 1849–1870, https://doi.org/10.5194/amt-15-1849-2022, 2022. a, b
Querel, R. and Swart, D.: NDACC ozone LIDAR data data sets from NIWA Lauder atmospheric research station, NDACC and EVDC Data Handling Facilities, NDACC/EVDC [data set], https://doi.org/10.21336/gen.0x48-sm13, 2020. a
Rodgers, C. D.: Inverse Methods for Atmospheric Sounding: Theory and Practice, World Scientific, https://doi.org/10.1142/3171, 2000. a, b, c, d, e
Rodgers, C. D. and Connor, B. J.: Intercomparison of remote sounding instruments, J. Geophys. Res.-Atmos., 108, 4116, https://doi.org/10.1029/2002JD002299, 2003. a, b, c, d, e
Rothman, L. S., Gordon, I. E., Barbe, A., Benner, D. C., Bernath, P. F., Birk, M., Boudon, V., Brown, L. R., Campargue, A., Champion, J. P., Chance, K., Coudert, L. H., Dana, V., Devi, V. M., Fally, S., Flaud, J. M., Gamache, R. R., Goldman, A., Jacquemart, D., Kleiner, I., Lacome, N., Lafferty, W. J., Mandin, J. Y., Massie, S. T., Mikhailenko, S. N., Miller, C. E., Moazzen-Ahmadi, N., Naumenko, O. V., Nikitin, A. V., Orphal, J., Perevalov, V. I., Perrin, A., Predoi-Cross, A., Rinsland, C. P., Rotger, M., Šimečková, M., Smith, M. A. H., Sung, K., Tashkun, S. A., Tennyson, J., Toth, R. A., Vandaele, A. C., and Vander Auwera, J.: The HITRAN 2008 molecular spectroscopic database, J. Quant. Spectrosc. Ra., 110, 533–572, https://doi.org/10.1016/j.jqsrt.2009.02.013, 2009. a
Rousseeuw, P. J. and Croux, C.: Alternatives to the Median Absolute Deviation, J. Am. Stat. Assoc., 88, 1273–1283, https://doi.org/10.1080/01621459.1993.10476408, 1993. a
Sakai, T., Uchino, O., Nagai, T., Liley, B., Morino, I., and Fujimoto, T.: Long-term variation of stratospheric aerosols observed with lidars over Tsukuba, Japan, from 1982 and Lauder, New Zealand, from 1992 to 2015, J. Geophys. Res.-Atmos., 121, 10283–10293, https://doi.org/10.1002/2016JD025132, 2016. a
Santer, B. D., Thorne, P. W., Haimberger, L., Taylor, K. E., Wigley, T. M. L., Lanzante, J. R., Solomon, S., Free, M., Gleckler, P. J., Jones, P. D., Karl, T. R., Klein, S. A., Mears, C., Nychka, D., Schmidt, G. A., Sherwood, S. C., and Wentz, F. J.: Consistency of modelled and observed temperature trends in the tropical troposphere, Int. J. Climatol., 28, 1703–1722, https://doi.org/10.1002/joc.1756, 2008. a
Sauvageat, E., Hocke, K., Maillard Barras, E., Hou, S., Errera, Q., Haefele, A., and Murk, A.: Microwave radiometer observations of the ozone diurnal cycle and its short-term variability over Switzerland, Atmos. Chem. Phys., 23, 7321–7345, https://doi.org/10.5194/acp-23-7321-2023, 2023. a
Schneider, M. and Hase, F.: Technical Note: Recipe for monitoring of total ozone with a precision of around 1 DU applying mid-infrared solar absorption spectra, Atmos. Chem. Phys., 8, 63–71, https://doi.org/10.5194/acp-8-63-2008, 2008. a
Schneider, M., Redondas, A., Hase, F., Guirado, C., Blumenstock, T., and Cuevas, E.: Comparison of ground-based Brewer and FTIR total column O3 monitoring techniques, Atmos. Chem. Phys., 8, 5535–5550, https://doi.org/10.5194/acp-8-5535-2008, 2008. a, b
Smale, D. and Robinson, J.: Infrared Fourier Transform Spectrometer (FTIR) Profile and total vertical column abundances above measurement site, NIWA [data set], https://www-air.larc.nasa.gov/missions/ndacc/data.html, last access: 18 November 2024. a
Smit, H. G. and Oltmans, S. J.: Ozone Data Quality Assessment (O3S-DQA): Resolving inhomogenities due to artifacts in long term ozone sounding records, in: AGU Fall Meeting Abstracts, San Francisco, California, USA, December 2012, AGU, vol. 2012, A53Q–0443, https://ui.adsabs.harvard.edu/abs/2012AGUFM.A53Q0443S (last access: 18 November 2024), 2012. a
Smit, H. G. J., Thompson, A. M., and ASOPOS panel: WMO/GAW Report: Ozonesonde Measurement Principles and Best Operational Practices, ASOPOS (Assessment of Standard Operating Procedures for Ozonesondes) 2.0, GAW Report No. 268, Geneva, Switzerland, https://library.wmo.int/idurl/4/57720 (last access: 18 November 2024), 2021. a
Smit, H. G. J., Poyraz, D., Van Malderen, R., Thompson, A. M., Tarasick, D. W., Stauffer, R. M., Johnson, B. J., and Kollonige, D. E.: New insights from the Jülich Ozone Sonde Intercomparison Experiment: calibration functions traceable to one ozone reference instrument, Atmos. Meas. Tech., 17, 73–112, https://doi.org/10.5194/amt-17-73-2024, 2024. a, b
Solomon, S.: Stratospheric ozone depletion: A review of concepts and history, Rev. Geophys., 37, 275–316, https://doi.org/10.1029/1999RG900008, 1999. a
Solomon, S., Ivy, D. J., Kinnison, D., Mills, M. J., Neely, R. R., and Schmidt, A.: Emergence of healing in the Antarctic ozone layer, Science, 353, 269–274, https://doi.org/10.1126/science.aae0061, 2016. a
Stauffer, R. M., Thompson, A. M., Kollonige, D. E., Tarasick, D. W., Van Malderen, R., Smit, H. G. J., Vömel, H., Morris, G. A., Johnson, B. J., Cullis, P. D., Stübi, R., Davies, J., and Yan, M. M.: An Examination of the Recent Stability of Ozonesonde Global Network Data, Earth and Space Science, 9, e2022EA002459, https://doi.org/10.1029/2022EA002459, 2022. a, b, c
Steck, T.: Methods for Determining Regularization for Atmospheric Retrieval Problems, Appl. Optics, 41, 1788–1797, https://doi.org/10.1364/AO.41.001788, 2002. a
Steinbrecht, W., Froidevaux, L., Fuller, R., Wang, R., Anderson, J., Roth, C., Bourassa, A., Degenstein, D., Damadeo, R., Zawodny, J., Frith, S., McPeters, R., Bhartia, P., Wild, J., Long, C., Davis, S., Rosenlof, K., Sofieva, V., Walker, K., Rahpoe, N., Rozanov, A., Weber, M., Laeng, A., von Clarmann, T., Stiller, G., Kramarova, N., Godin-Beekmann, S., Leblanc, T., Querel, R., Swart, D., Boyd, I., Hocke, K., Kämpfer, N., Maillard Barras, E., Moreira, L., Nedoluha, G., Vigouroux, C., Blumenstock, T., Schneider, M., García, O., Jones, N., Mahieu, E., Smale, D., Kotkamp, M., Robinson, J., Petropavlovskikh, I., Harris, N., Hassler, B., Hubert, D., and Tummon, F.: An update on ozone profile trends for the period 2000 to 2016, Atmos. Chem. Phys., 17, 10675–10690, https://doi.org/10.5194/acp-17-10675-2017, 2017. a
Stevenson, D. S., Dentener, F. J., Schultz, M. G., Ellingsen, K., van Noije, T. P. C., Wild, O., Zeng, G., Amann, M., Atherton, C. S., Bell, N., Bergmann, D. J., Bey, I., Butler, T., Cofala, J., Collins, W. J., Derwent, R. G., Doherty, R. M., Drevet, J., Eskes, H. J., Fiore, A. M., Gauss, M., Hauglustaine, D. A., Horowitz, L. W., Isaksen, I. S. A., Krol, M. C., Lamarque, J. F., Lawrence, M. G., Montanaro, V., Müller, J. F., Pitari, G., Prather, M. J., Pyle, J. A., Rast, S., Rodriguez, J. M., Sanderson, M. G., Savage, N. H., Shindell, D. T., Strahan, S. E., Sudo, K., and Szopa, S.: Multimodel ensemble simulations of present-day and near-future tropospheric ozone, J. Geophys. Res.-Atmos., 111, D08301, https://doi.org/10.1029/2005JD006338, 2006. a
Sun, Y., Palm, M., Liu, C., Hase, F., Griffith, D., Weinzierl, C., Petri, C., Wang, W., and Notholt, J.: The influence of instrumental line shape degradation on NDACC gas retrievals: total column and profile, Atmos. Meas. Tech., 11, 2879–2896, https://doi.org/10.5194/amt-11-2879-2018, 2018. a
Swart, D. P., Spakman, J., and Bergwerff, H. B.: RIVM's stratospheric ozone lidar for NDSC station Lauder: system description and first results, in: Papers of the 17th International Laser Radar Conference, 17th International Laser Radar Conference ILRC, Sendai, Japan, July 1994, vol. 405, p. 408, https://www.rivm.nl/publicaties/rivms-stratospheric-ozone-lidar-for-ndsc-station-lauder-system-description-and-first (last access: 18 November 2024), 1994. a
Szopa, S., Naik, V., Adhikary, B., Artaxo, P., Berntsen, T., Collins, W., Fuzzi, S., Gallardo, L., Kiendler-Scharr, A., Klimont, Z., Liao, H., Unger, N., and Zanis, P.: Short-Lived Climate Forcers, in: Climate Change 2021: The Physical Science Basis. Contribution of Working Group I to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change, edited by: Masson-Delmotte, V., Zhai, P., Pirani, A., Connors, S. L., Péan, C., Berger, S., Caud, N., Chen, Y., Goldfarb, L., Gomis, M. I., Huang, M., Leitzell, K., Lonnoy, E., Matthews, J. B. R., Maycock, T. K., Waterfield, T., Yelekçi, O., Yu, R., and Zhou, B., Cambridge University Press, Cambridge, United Kingdom and New York, NY, USA, 817–922, https://doi.org/10.1017/9781009157896.008, 2021. a
Tikhonov, A.: Solution of Incorrectly Formulated Problems and the Regularization Method, Soviet Mathematics, 4, 1035–1038, 1963. a
Tsou, J. J., Connor, B. J., Parrish, A., Pierce, R. B., Boyd, I. S., Bodeker, G. E., Chu, W. P., Russell, J. M., Swart, D. P. J., and McGee, T. J.: NDSC millimeter wave ozone observations at Lauder, New Zealand, 1992-1998: Improved methodology, validation, and variation study, J. Geophys. Res., 105, 24263–24281, https://doi.org/10.1029/2000JD900292, 2000. a
Van Malderen, R.: TOAR-II HEGIFTOM: Homogenized Ozonesondes Time Series, Royal Meteorological Institute of Belgium [data set], https://hegiftom.meteo.be/datasets/ozonesondes, last access: 18 November 2024. a
Vigouroux, C., De Mazière, M., Demoulin, P., Servais, C., Hase, F., Blumenstock, T., Kramer, I., Schneider, M., Mellqvist, J., Strandberg, A., Velazco, V., Notholt, J., Sussmann, R., Stremme, W., Rockmann, A., Gardiner, T., Coleman, M., and Woods, P.: Evaluation of tropospheric and stratospheric ozone trends over Western Europe from ground-based FTIR network observations, Atmos. Chem. Phys., 8, 6865–6886, https://doi.org/10.5194/acp-8-6865-2008, 2008. a, b, c, d, e, f, g, h, i, j
Vigouroux, C., Blumenstock, T., Coffey, M., Errera, Q., García, O., Jones, N. B., Hannigan, J. W., Hase, F., Liley, B., Mahieu, E., Mellqvist, J., Notholt, J., Palm, M., Persson, G., Schneider, M., Servais, C., Smale, D., Thölix, L., and De Mazière, M.: Trends of ozone total columns and vertical distribution from FTIR observations at eight NDACC stations around the globe, Atmos. Chem. Phys., 15, 2915–2933, https://doi.org/10.5194/acp-15-2915-2015, 2015. a
Walshaw, C. D.: G. M. B. Dobson – The man and his work, Planet. Space Sci., 37, 1485–1507, https://doi.org/10.1016/0032-0633(89)90141-4, 1989. a
WMO: Scientific Assessment of Ozone Depletion: 2018, Global Ozone Research and Monitoring Project, World Meteorological Organization, Report No. 58, Geneva, Switzerland, 588 pp., https://csl.noaa.gov/assessments/ozone/2018/downloads/2018OzoneAssessment.pdf (last access: 18 November 2024), 2018. a
WMO: Scientific Assessment of Ozone Depletion: 2022 World Meteorological Organization, GAW Report No. 278, Geneva, Switzerland, 509 pp., https://library.wmo.int/idurl/4/58360 (last access: 18 November 2024), 2022. a, b
Zeng, G., Querel, R., Shiona, H., Poyraz, D., Van Malderen, R., Geddes, A., Smale, P., Smale, D., Robinson, J., and Morgenstern, O.: Analysis of a newly homogenised ozonesonde dataset from Lauder, New Zealand, Atmos. Chem. Phys., 24, 6413–6432, https://doi.org/10.5194/acp-24-6413-2024, 2024. a
- Abstract
- Introduction
- Ground-based measurements
- Intercomparison setup
- Results
- Comparison to the LOTUS trend analysis study (Godin-Beekmann et al., 2022)
- Conclusions
- Appendix A: Influence of FTIR retrieval setup
- Appendix B: Choice of time window
- Appendix C: Effects of smoothing
- Appendix D: Calibration of FTIR and Dobson
- Appendix E: Effect of discontinuities
- Data availability
- Author contributions
- Competing interests
- Disclaimer
- Special issue statement
- Acknowledgements
- Financial support
- Review statement
- References
- Abstract
- Introduction
- Ground-based measurements
- Intercomparison setup
- Results
- Comparison to the LOTUS trend analysis study (Godin-Beekmann et al., 2022)
- Conclusions
- Appendix A: Influence of FTIR retrieval setup
- Appendix B: Choice of time window
- Appendix C: Effects of smoothing
- Appendix D: Calibration of FTIR and Dobson
- Appendix E: Effect of discontinuities
- Data availability
- Author contributions
- Competing interests
- Disclaimer
- Special issue statement
- Acknowledgements
- Financial support
- Review statement
- References