Articles | Volume 10, issue 10
https://doi.org/10.5194/amt-10-3783-2017
https://doi.org/10.5194/amt-10-3783-2017
Research article
 | 
17 Oct 2017
Research article |  | 17 Oct 2017

Design of an ozone and nitrogen dioxide sensor unit and its long-term operation within a sensor network in the city of Zurich

Michael Mueller, Jonas Meyer, and Christoph Hueglin

Download

Interactive discussion

Status: closed
Status: closed
AC: Author comment | RC: Referee comment | SC: Short comment | EC: Editor comment
Printer-friendly Version - Printer-friendly version Supplement - Supplement

Peer-review completion

AR: Author's response | RR: Referee report | ED: Editor decision
AR by Michael Müller on behalf of the Authors (28 Jun 2017)  Author's response   Manuscript 
ED: Publish as is (06 Jul 2017) by Francis Pope
AR by Michael Müller on behalf of the Authors (14 Jul 2017)
Download
Short summary
This study describes the design of a sensor unit featuring NO2 and O3 sensors for applications such as ambient air quality monitoring. The paper presents the sensor calibration, the testing procedure and the long-term deployment of the sensor units in the city of Zurich. Main conclusions are the necessity of a proper mathematical description of the sensors as well as a concept to monitor sensor performance during operation, e.g. by linking low-cost sensors to traditional infrastructure.