Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 3.668 IF 3.668
  • IF 5-year value: 3.707 IF 5-year
    3.707
  • CiteScore value: 6.3 CiteScore
    6.3
  • SNIP value: 1.383 SNIP 1.383
  • IPP value: 3.75 IPP 3.75
  • SJR value: 1.525 SJR 1.525
  • Scimago H <br class='hide-on-tablet hide-on-mobile'>index value: 77 Scimago H
    index 77
  • h5-index value: 49 h5-index 49
AMT | Articles | Volume 11, issue 4
Atmos. Meas. Tech., 11, 2477–2484, 2018
https://doi.org/10.5194/amt-11-2477-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.
Atmos. Meas. Tech., 11, 2477–2484, 2018
https://doi.org/10.5194/amt-11-2477-2018
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.

Research article 27 Apr 2018

Research article | 27 Apr 2018

Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range

Ralf Zuber et al.

Viewed

Total article views: 2,177 (including HTML, PDF, and XML)
HTML PDF XML Total BibTeX EndNote
1,458 635 84 2,177 41 49
  • HTML: 1,458
  • PDF: 635
  • XML: 84
  • Total: 2,177
  • BibTeX: 41
  • EndNote: 49
Views and downloads (calculated since 28 Sep 2017)
Cumulative views and downloads (calculated since 28 Sep 2017)

Viewed (geographical distribution)

Total article views: 2,079 (including HTML, PDF, and XML) Thereof 2,066 with geography defined and 13 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 

Cited

Saved (final revised paper)

No saved metrics found.

Saved (preprint)

No saved metrics found.

Discussed (final revised paper)

No discussed metrics found.

Discussed (preprint)

No discussed metrics found.
Latest update: 09 Aug 2020
Publications Copernicus
Download
Short summary
A compact array spectroradiometer technology that enables precise and robust measurements of UV spectral irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range, is physically reduced so that no other stray-light reduction methods are needed. During an international total ozone measurement intercomparison, the high quality was verified.
A compact array spectroradiometer technology that enables precise and robust measurements of UV...
Citation