Long-term climatology of vertical profiles of polarimetric variables and ice-microphysical retrievals at X-band – Part 1: Radar calibration
Download
- Final revised paper (published on 02 Oct 2026)
- Preprint (discussion started on 02 Mar 2026)
Interactive discussion
Status: closed
Comment types: AC – author | RC – referee | CC – community | EC – editor | CEC – chief editor
| : Report abuse
-
RC1: 'Comment on egusphere-2026-493', Anonymous Referee #1, 24 Mar 2026
- AC1: 'Reply on RC1', Tobias Scharbach, 13 Apr 2026
-
RC2: 'Comment on egusphere-2026-493', Anonymous Referee #2, 03 May 2026
- AC2: 'Reply on RC2', Tobias Scharbach, 29 May 2026
Peer review completion
AR – Author's response | RR – Referee report | ED – Editor decision | EF – Editorial file upload
AR by Tobias Scharbach on behalf of the Authors (25 Jun 2026)
Author's response
Author's tracked changes
Manuscript
ED: Referee Nomination & Report Request started (26 Jun 2026) by Leonie von Terzi
ED: Publish as is (07 Sep 2026) by Leonie von Terzi
AR by Tobias Scharbach on behalf of the Authors (07 Sep 2026)
Author's response
Post-review adjustments
AA – Author's adjustment | EA – Editor approval
AA by Tobias Scharbach on behalf of the Authors (24 Sep 2026)
Author's adjustment
Manuscript
EA: Adjustments approved (24 Sep 2026) by Leonie von Terzi
The paper provides a very comprehensive analysis of the ZDR biases during a decade-long period of continuous observations with the X-band polarimetric radar at the University of Bonn and suggests a new “reverse Z – ZDR method” for absolute calibration of Z based on the measurements of calibrated ZDR. In the first part of the manuscript, the long-term statistics of the ZDR biases estimated using the traditional “bird-bathing” and QVP-based calibration methodologies are presented illustrating temporal trends and differences between the outputs of the two techniques. This is a very valuable part of the study that demonstrates realistic spans of the ZDR biases which seem to be quite sensitive to the changes of the radar hardware and software. The message is also that the bird-bathing calibration methodology is not a golden standard at all.
I have a few questions / concerns regarding the reverse Z – ZDR method.