Articles | Volume 6, issue 3
https://doi.org/10.5194/amt-6-677-2013
© Author(s) 2013. This work is distributed under
the Creative Commons Attribution 3.0 License.On the absolute calibration of SO2 cameras
Download
- Final revised paper (published on 14 Mar 2013)
- Preprint (discussion started on 03 Sep 2012)
Interactive discussion
AC: Author comment | RC: Referee comment | SC: Short comment | EC: Editor comment


-
RC C2765: 'Review for "On the absolute calibration of SO2 cameras"', Anonymous Referee #2, 07 Nov 2012
-
AC C3793: 'Answers to the interactive comments by anonymous Referee #2', Peter Lübcke, 04 Feb 2013
-
AC C3793: 'Answers to the interactive comments by anonymous Referee #2', Peter Lübcke, 04 Feb 2013
-
RC C3458: 'Review of “On the absolute calibration of SO2 cameras” by Lübcke et al.', Anonymous Referee #3, 31 Dec 2012
-
AC C3794: 'Answers to the interactive comments by anonymous Referee #3', Peter Lübcke, 04 Feb 2013
-
AC C3794: 'Answers to the interactive comments by anonymous Referee #3', Peter Lübcke, 04 Feb 2013