Articles | Volume 14, issue 5
Atmos. Meas. Tech., 14, 3935–3951, 2021
https://doi.org/10.5194/amt-14-3935-2021
Atmos. Meas. Tech., 14, 3935–3951, 2021
https://doi.org/10.5194/amt-14-3935-2021

Research article 27 May 2021

Research article | 27 May 2021

Internal consistency of the IAGOS ozone and carbon monoxide measurements for the last 25 years

Romain Blot et al.

Download

Interactive discussion

Status: closed
Status: closed
AC: Author comment | RC: Referee comment | SC: Short comment | EC: Editor comment
Printer-friendly Version - Printer-friendly version Supplement - Supplement

Peer-review completion

AR: Author's response | RR: Referee report | ED: Editor decision
AR by Romain Blot on behalf of the Authors (30 Mar 2021)  Author's response    Author's tracked changes    Manuscript
ED: Publish as is (05 Apr 2021) by Hendrik Fuchs
AR by Romain Blot on behalf of the Authors (07 Apr 2021)  Author's response    Manuscript
Download
Short summary
A lack of information about temporal changes in measurement uncertainties is an area of concern for long-term trend studies of the key compounds which have a direct or indirect impact on climate change. The IAGOS program has measured O3 and CO within the troposphere and lower stratosphere for more than 25 years. In this study, we demonstrated that the IAGOS database can be treated as one continuous program and is therefore appropriate for studies of long-term trends.