Articles | Volume 12, issue 3
https://doi.org/10.5194/amt-12-1861-2019
https://doi.org/10.5194/amt-12-1861-2019
Research article
 | 
20 Mar 2019
Research article |  | 20 Mar 2019

Using collision-induced dissociation to constrain sensitivity of ammonia chemical ionization mass spectrometry (NH4+ CIMS) to oxygenated volatile organic compounds

Alexander Zaytsev, Martin Breitenlechner, Abigail R. Koss, Christopher Y. Lim, James C. Rowe, Jesse H. Kroll, and Frank N. Keutsch

Related authors

Application of chemical derivatization techniques combined with chemical ionization mass spectrometry to detect stabilized Criegee intermediates and peroxy radicals in the gas phase
Alexander Zaytsev, Martin Breitenlechner, Anna Novelli, Hendrik Fuchs, Daniel A. Knopf, Jesse H. Kroll, and Frank N. Keutsch
Atmos. Meas. Tech., 14, 2501–2513, https://doi.org/10.5194/amt-14-2501-2021,https://doi.org/10.5194/amt-14-2501-2021, 2021
Short summary
Dimensionality-reduction techniques for complex mass spectrometric datasets: application to laboratory atmospheric organic oxidation experiments
Abigail R. Koss, Manjula R. Canagaratna, Alexander Zaytsev, Jordan E. Krechmer, Martin Breitenlechner, Kevin J. Nihill, Christopher Y. Lim, James C. Rowe, Joseph R. Roscioli, Frank N. Keutsch, and Jesse H. Kroll
Atmos. Chem. Phys., 20, 1021–1041, https://doi.org/10.5194/acp-20-1021-2020,https://doi.org/10.5194/acp-20-1021-2020, 2020
Short summary
Mechanistic study of the formation of ring-retaining and ring-opening products from the oxidation of aromatic compounds under urban atmospheric conditions
Alexander Zaytsev, Abigail R. Koss, Martin Breitenlechner, Jordan E. Krechmer, Kevin J. Nihill, Christopher Y. Lim, James C. Rowe, Joshua L. Cox, Joshua Moss, Joseph R. Roscioli, Manjula R. Canagaratna, Douglas R. Worsnop, Jesse H. Kroll, and Frank N. Keutsch
Atmos. Chem. Phys., 19, 15117–15129, https://doi.org/10.5194/acp-19-15117-2019,https://doi.org/10.5194/acp-19-15117-2019, 2019
Short summary
Validity and limitations of simple reaction kinetics to calculate concentrations of organic compounds from ion counts in PTR-MS
Rupert Holzinger, W. Joe F. Acton, William J. Bloss, Martin Breitenlechner, Leigh R. Crilley, Sébastien Dusanter, Marc Gonin, Valerie Gros, Frank N. Keutsch, Astrid Kiendler-Scharr, Louisa J. Kramer, Jordan E. Krechmer, Baptiste Languille, Nadine Locoge, Felipe Lopez-Hilfiker, Dušan Materić, Sergi Moreno, Eiko Nemitz, Lauriane L. J. Quéléver, Roland Sarda Esteve, Stéphane Sauvage, Simon Schallhart, Roberto Sommariva, Ralf Tillmann, Sergej Wedel, David R. Worton, Kangming Xu, and Alexander Zaytsev
Atmos. Meas. Tech., 12, 6193–6208, https://doi.org/10.5194/amt-12-6193-2019,https://doi.org/10.5194/amt-12-6193-2019, 2019
Investigation of the oxidation of methyl vinyl ketone (MVK) by OH radicals in the atmospheric simulation chamber SAPHIR
Hendrik Fuchs, Sascha Albrecht, Ismail–Hakki Acir, Birger Bohn, Martin Breitenlechner, Hans-Peter Dorn, Georgios I. Gkatzelis, Andreas Hofzumahaus, Frank Holland, Martin Kaminski, Frank N. Keutsch, Anna Novelli, David Reimer, Franz Rohrer, Ralf Tillmann, Luc Vereecken, Robert Wegener, Alexander Zaytsev, Astrid Kiendler-Scharr, and Andreas Wahner
Atmos. Chem. Phys., 18, 8001–8016, https://doi.org/10.5194/acp-18-8001-2018,https://doi.org/10.5194/acp-18-8001-2018, 2018
Short summary

Related subject area

Subject: Gases | Technique: Laboratory Measurement | Topic: Instruments and Platforms
Response of protonated, adduct, and fragmented ions in Vocus proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS)
Fangbing Li, Dan Dan Huang, Linhui Tian, Bin Yuan, Wen Tan, Liang Zhu, Penglin Ye, Douglas Worsnop, Ka In Hoi, Kai Meng Mok, and Yong Jie Li
Atmos. Meas. Tech., 17, 2415–2427, https://doi.org/10.5194/amt-17-2415-2024,https://doi.org/10.5194/amt-17-2415-2024, 2024
Short summary
Absorption of volatile organic compounds (VOCs) by polymer tubing: implications for indoor air and use as a simple gas-phase volatility separation technique
Melissa A. Morris, Demetrios Pagonis, Douglas A. Day, Joost A. de Gouw, Paul J. Ziemann, and Jose L. Jimenez
Atmos. Meas. Tech., 17, 1545–1559, https://doi.org/10.5194/amt-17-1545-2024,https://doi.org/10.5194/amt-17-1545-2024, 2024
Short summary
A flexible device to produce a gas stream with a precisely controlled water vapour mixing ratio and isotope composition based on microdrop dispensing technology
Harald Sodemann, Alena Dekhtyareva, Alvaro Fernandez, Andrew Seidl, and Jenny Maccali
Atmos. Meas. Tech., 16, 5181–5203, https://doi.org/10.5194/amt-16-5181-2023,https://doi.org/10.5194/amt-16-5181-2023, 2023
Short summary
Revision of an open-split-based dual-inlet system for elemental and isotope ratio mass spectrometers with a focus on clumped-isotope measurements
Stephan Räss, Peter Nyfeler, Paul Wheeler, Will Price, and Markus Christian Leuenberger
Atmos. Meas. Tech., 16, 4489–4505, https://doi.org/10.5194/amt-16-4489-2023,https://doi.org/10.5194/amt-16-4489-2023, 2023
Short summary
Characterisation of gaseous iodine species detection using the multi-scheme chemical ionisation inlet 2 with bromide and nitrate chemical ionisation methods
Xu-Cheng He, Jiali Shen, Siddharth Iyer, Paxton Juuti, Jiangyi Zhang, Mrisha Koirala, Mikko M. Kytökari, Douglas R. Worsnop, Matti Rissanen, Markku Kulmala, Norbert M. Maier, Jyri Mikkilä, Mikko Sipilä, and Juha Kangasluoma
Atmos. Meas. Tech., 16, 4461–4487, https://doi.org/10.5194/amt-16-4461-2023,https://doi.org/10.5194/amt-16-4461-2023, 2023
Short summary

Cited articles

Aljawhary, D., Lee, A. K. Y., and Abbatt, J. P. D.: High-resolution chemical ionization mass spectrometry (ToF-CIMS): application to study SOA composition and processing, Atmos. Meas. Tech., 6, 3211–3224, https://doi.org/10.5194/amt-6-3211-2013, 2013. 
Atkinson R.: Atmospheric chemistry of VOCs and NOx, Atmos. Environ., 34, 2063–2101, 2000. 
Berresheim, H., Elste, T., Plass-Dülmer, C., Eisele, F. L., and Tanner, D. J.: Chemical ionization mass spectrometer for long-term measurements of atmospheric OH and H2SO4, Int. J. Mass Spectrom., 202, 91–109, https://doi.org/10.1016/S1387-3806(00)00233-5, 2000. 
Bertram, T. H., Kimmel, J. R., Crisp, T. A., Ryder, O. S., Yatavelli, R. L. N., Thornton, J. A., Cubison, M. J., Gonin, M., and Worsnop, D. R.: A field-deployable, chemical ionization time-of-flight mass spectrometer, Atmos. Meas. Tech., 4, 1471–1479, https://doi.org/10.5194/amt-4-1471-2011, 2011. 
Blake, R. S., Whyte, C., Hughes, C. O., Ellis, A. M., and Monks, P. S.: Demonstration of Proton-Transfer Reaction Time-of-Flight Mass Spectrometry for Real-Time Analysis of Trace Volatile Organic Compounds, Anal. Chem., 76, 3841–3845, https://doi.org/10.1021/ac0498260, 2004. 
Download
Short summary
We present the development of a chemical ionization mass spectrometer which can be operated with either ammonium (NH4+) or hydronium (H3O+) as the reagent ion. We describe a mass spectrometric voltage scanning procedure based on collision-induced dissociation that allows us to determine the stability of detected ammonium–organic ions and hence constrain the sensitivity of the instrument to a wide range of organic compounds that cannot be calibrated directly.