Articles | Volume 12, issue 3
https://doi.org/10.5194/amt-12-1685-2019
https://doi.org/10.5194/amt-12-1685-2019
Research article
 | 
15 Mar 2019
Research article |  | 15 Mar 2019

The interference of tetrachloromethane in the measurement of benzene in the air by a gas chromatography–photoionisation detector (GC-PID)

Cristina Romero-Trigueros, María Esther González, Marta Doval Miñarro, and Enrique González Ferradás

Related authors

Influence of sample temperature and environmental humidity on measurements of benzene in ambient air by transportable GC-PID
Cristina Romero-Trigueros, Marta Doval Miñarro, Esther González Duperón, and Enrique González Ferradás
Atmos. Meas. Tech., 10, 4013–4022, https://doi.org/10.5194/amt-10-4013-2017,https://doi.org/10.5194/amt-10-4013-2017, 2017
Short summary

Related subject area

Subject: Gases | Technique: Laboratory Measurement | Topic: Validation and Intercomparisons
Reactive uptake coefficients for multiphase reactions determined by a dynamic chamber system
Guo Li, Hang Su, Meng Li, Uwe Kuhn, Guangjie Zheng, Lei Han, Fengxia Bao, Ulrich Pöschl, and Yafang Cheng
Atmos. Meas. Tech., 15, 6433–6446, https://doi.org/10.5194/amt-15-6433-2022,https://doi.org/10.5194/amt-15-6433-2022, 2022
Short summary
Influence of CO2 adsorption on cylinders and fractionation of CO2 and air during the preparation of a standard mixture
Nobuyuki Aoki, Shigeyuki Ishidoya, Shohei Murayama, and Nobuhiro Matsumoto
Atmos. Meas. Tech., 15, 5969–5983, https://doi.org/10.5194/amt-15-5969-2022,https://doi.org/10.5194/amt-15-5969-2022, 2022
Short summary
Development of an SI-traceable transmission curve reference material to improve comparability of proton transfer reaction mass spectrometry measurements
David Robert Worton, Sergi Moreno, Kieran O'Daly, and Rupert Holzinger
Atmos. Meas. Tech. Discuss., https://doi.org/10.5194/amt-2022-243,https://doi.org/10.5194/amt-2022-243, 2022
Revised manuscript accepted for AMT
Short summary
Detection of nitrous acid in the atmospheric simulation chamber SAPHIR using open-path incoherent broadband cavity-enhanced absorption spectroscopy and extractive long-path absorption photometry
Sophie Dixneuf, Albert A. Ruth, Rolf Häseler, Theo Brauers, Franz Rohrer, and Hans-Peter Dorn
Atmos. Meas. Tech., 15, 945–964, https://doi.org/10.5194/amt-15-945-2022,https://doi.org/10.5194/amt-15-945-2022, 2022
Short summary
Behavior of KCl sorbent traps and KCl trapping solutions used for atmospheric mercury speciation: stability and specificity
Jan Gačnik, Igor Živković, Sergio Ribeiro Guevara, Radojko Jaćimović, Jože Kotnik, Gianmarco De Feo, Matthew A. Dexter, Warren T. Corns, and Milena Horvat
Atmos. Meas. Tech., 14, 6619–6631, https://doi.org/10.5194/amt-14-6619-2021,https://doi.org/10.5194/amt-14-6619-2021, 2021
Short summary

Cited articles

Atkinson, R.: Atmospheric chemistry of VOCs and NOx, Atmos. Environ., 34, 2063–2101, https://doi.org/10.1016/S1352-2310(99)00460-4, 2000. 
ATSDR: Public Health Statement: Carbon Tetrachloride, available at: https://www.atsdr.cdc.gov/toxprofiles/tp30-c1-b.pdf (last access: 6 February 2019), 2005. 
Bahadar, H., Mostafalou, S., and Abdollahi, M.: Current understandings and perspectives on non-cancer health effects of benzene: A global concern, Toxicol. Appl. Pharmacol., 276, 83–94, https://doi.org/10.1016/j.taap.2014.02.012, 2014. 
Brosas-Montecastro, D.: Ambient air monitoring of hazardous volatile organic compounds in Seattle, Washinton neighborhoods: Trends and implications, PhD Thesis, Washington State University, USA, 86 pp., 2008. 
CEN: EN 14662-1 Ambient air quality, Standard method for measurement of benzene concentrations, Pumped sampling followed by thermal desorption and gas chromatography, 2005a. 
Download
Short summary
Determining benzene in ambient air is mandatory in the European Union. The reference measuring technique is by gas chromatography (GC), and a photometric ionisation detector is recommended. This study shows that the simultaneous presence of benzene and tetrachloromethane causes a significant decrease in GC–photoionisation detector (GC-PID) readings. Given the importance of this behaviour, a possible mechanism was proposed. This study highlights the uncertainty of measuring benzene with a GC-PID.